Home

Digital Phosphor Oscilloscopes

image

Contents

1. External Time Base Reference In BNC connector time base system can phase lock to external 10 MHz reference Time Base Reference Out BNC connector provides TTL compatible output of internal 10 MHz reference oscillator Aux Trigger Output BNC connector provides a TTL compatible polarity switchable pulse when the oscilloscope triggers GPIB Port IEEE 488 2 standard Physical Characteristics Benchtop Configuration Dimensions mm in Height 292 11 48 Width 451 17 75 Depth 265 10 44 Weight kg lbs Net 19 32 Shipping 28 9 63 10 Rackmount Configuration Dimensions mm in Height O20 1225 Width 479 18 85 Depth from rack 231 75 9 12 mounting ear to back of instrument Weight kg Ibs Net 17 4 3a Rackmount Kit 2 5 5 5 Mechanical Cooling Required Clearance mm in Top 0 0 Bottom 0 0 Left side 76 3 Right Side 0 0 Front 0 0 Rear 0 0 Environmental Temperature Operating 0 C to 50 C excluding CD R W drive 10 C to 45 C including CD R W drive Non operating 40 C to 71 C Digital Phosphor Oscilloscopes gt DPO7000 Series Humidity Operating 5 to 95 relative humidity RH with a maximum wet bulb temperature of 29 C at or below 50 C non condensing Upper limit derated to 45 RH above 30 C up to 50 C Non operating 5 to 95 relative humidity RH with a maximum wet bulb temperature of 29 C at or below 60 C non condensing Upper limit derated t
2. common and more advanced like FFT and Spectral al eee ix igg USB compliance testing 11 For Insight into Your High speed Serial Designs Optional NRZ Serial Pattern triggering plus Recovered Clock and Recovered Data avail able on the front of the DPO7254 or the DPO7354 instruments 12 A Breadth of Optional Software Packages for Expanded Wave form Analysis Digital Phosphor Oscilloscopes www tektronix com oscilloscopes 9 Digital Phosphor Oscilloscopes gt DPO7000 Series gt Time Base System DPO7054 DPO7104 DPO7254 DPO7354 Time Base Range 100 ps div to 1000 s div 50 ps div to 1000 s div 20 ps div to 1000 s div with Opt 2SR 50 ps div to 1000 s div 20 ps div to 1000 s div Time Resolution in ET IT mode 1 ps 500 fs 250 fs with Opt 2SR 500 fs 250 fs Time Base Delay Time Range 5 ns to 250 s Channel to Channel Deskew Range 75 ns Delta Time Measurement Accuracy 0 06 sample rate 2 5 ppm x Reading RMS Trigger Jitter RMS 1 5 PS ays typical Jitter Noise Floor lt 1 PS ans lt 2 ps peak for record duration lt 10 us typical lt 2 5 PSays for record duration lt 30 ms lt 65 parts trillion for record durations lt 10 s Time Base Accuracy 2 5 ppm Aging lt 1 ppm per year Acquisition System DPO7054 DPO7104 DPO7254 DPO7354 Real time Sample Rates 1 Channel max 10 GS s 20 GS s 40 GS s With Opt 2SR 20 GS s 40 GS s 2 Channels max 5 GS s 10 GS s 20 GS s W
3. Germany 49 221 94 77 400 Hong Kong 852 2585 6688 India 91 80 22275577 Italy 39 02 25086 1 Japan 81 3 6714 3010 Luxembourg 44 0 1344 392400 Mexico Central America amp Caribbean 52 55 5424700 Middle East Asia and North Africa 41 52 675 3777 The Netherlands O90 02 021797 Norway 800 16098 People s Republic of China 86 10 6235 1230 Poland 41 52 675 3777 Portugal 80 08 12370 Republic of Korea 82 2 528 5299 Russia amp CIS 7 495 7484900 South Africa 27 11 254 8360 Spain 34 901 988 054 Sweden 020 08 80371 Switzerland 41 52 675 3777 Taiwan 886 2 2722 9622 United Kingdom amp Eire 44 0 1344 392400 USA 1 800 426 2200 For other areas contact Tektronix Inc at 1 503 627 7111 Updated 15 September 2006 Our most up to date product information is available at www tektronix com Product s are manufactured eer 150 9001 in ISO registered facilities Samna za Copyright 2007 Tektronix All rights reserved Tektronix products are covered by U S and foreign patents issued and pending Information in this publication supersedes that in all previously published material Specification and price change privileges reserved TEKTRONIX and TEK are registered trademarks of Tektronix Inc All other trade names referenced are the service marks trademarks or registered trademarks of their respective companies 1 07 DV AWOW AMW 19046 4 Tektronix Pa Enabling Innovati
4. desktop or on an external PC Maximize the probability of capturing elusive glitches and other infrequent events with FastAcq acquisition mode Accelerate the Debug of Complex Electrical Designs FastAcq Acquisition Mode Expedites Debugging by Clearly Showing Imperfections More than just color grading FastAcq enabled by Tektronix proprietary DPX acquisition technology captures signals up to more than 250 000 waveforms per second on all 4 channels simultaneously dramatically increasing the probability of discovering infrequent fault events And with a simple turn of the intensity knob you can clearly see a world others don t see because frequency of occurrence is color coded Some oscilloscope vendors claim high waveform capture rates for short bursts of time but only the DPO7000 Series enabled by DPX technology can deliver these fast waveform capture rates on a sustained basis saving minutes hours or even days by quickly revealing the nature of faults so sophisticated trigger modes can be applied to isolate them Isolate glitches down to 200 ps wide The Ability to Trigger an Oscilloscope on Events of Interest is Paramount in Complex Signal Debug and Validation Whether you re trying to find a system error or need to isolate a section of a complex signal for further analysis Tektronix Pinpoint triggering provides the solution The Pinpoint trigger system uses Silicon Germanium SiGe t
5. Opt C5 Opt R3 Repair Service 3 years Opt R5 Repair Service 5 years Recommended Accessories Probes TCP202 DC coupled current probe TDP0500 500 Mhz TekVPI high voltage differ ential probe TDP1000 1 GHz TekVPI high voltage differential probe TAP3500 3 5 GHz TekVPI active single ended probe TAP2500 2 5 GHz TekVPI active single ended probe TAP1500 1 5 GHz TekVPI active single ended probe TCP0030 120 MHz TekVPI AC DC 30 A current probe TPA BNC TekProbe BNC Level 2 to TekVPI adapter P6139A 500 MHz passive probe P6158 3 GHz 20x low C probe P6247 1 GHz differential probe P6243 1 GHz active probe P6245 1 5 GHz active probe P6248 1 5 GHz differential probe P6330 3 GHz differential probe P6246 400 MHz differential probe P6101B 1x passive probe 15 MHz TCPA300 TCPA400 Series current measure ment systems P5200 P5205 P5210 7 High voltage differential probes P5100 P6015A High voltage probes Cables GPIB Cable 1 m Order 012 0991 01 GPIB Cable 2 m Order 012 0991 00 RS 232 Cable Order 012 1298 00 Centronics Cable Order 012 1214 00 Accessories Mini Keyboard USB interface Order 119 7083 00 Keyboard USB interface Full size keyboard with 4 port USB hub Order 119 6297 00 Service Manual Order 071 1740 xx Transit Case Order 0
6. embedded bus waveform data can be moved directly from acquisition to analysis applications on the Windows desktop at much faster speeds than conventional GPIB transfers Tektronix implementation of industry standard protocols such as TekVISA interface and ActiveX controls are included for using and enhancing Windows applications for data analysis and documentation IVI COM Instrument drivers are included to enable easy communication with the oscilloscope using GPIB serial data and LAN connec tions from programs running on the instrument or an external PC Or use the Software Developer s Kit SDK to helo create custom software to automate multi step processes in waveform collection and analysis with Visual BASIC C C MATLAB LabVIEW LabWindows CVI gt Drag and drop menu items of interest to create the MyScope control window aw t ral p a i k gt Capture data into Microsoft Excel using the unique Excel toolbar and create custom reports using the Word toolbar and other common Application Development Environments ADE Integration of the oscilloscope with external PCs and non Windows hosts is also supported by the DPO7000 Series software solutions In addition the OpenChoice architecture provides a comprehensive software infrastructure for faster more versatile operations Data transfer programs such as the Excel or Word toolbar are used to simplify analysis and documentation on the Windows
7. ously to compare them Unmatched Versatility With the MyScope Feature Create Your Own Control Windows With Only the Controls Features and Capabilities that You Care About Easily create your own personalized toolbox of oscilloscope features in a matter of minutes using a simple visual drag and drop process Once created these custom control windows are easily accessed through a dedicated MyScope button and menu selection on the oscil loscope button menu bar just like any other control window You can make an unlimited number of custom control windows enabling each person who uses the oscilloscope in a shared environment to have their own unique control window MyScope contro windows will benefit all oscilloscope users eliminating the ramp up time that many face when returning to the lab after not using an oscilloscope for a while and enables the power user to be far more efficient Everything you need is found in one control window rather than having to constantly navigate through menu after menu to repeat similar tasks 2 Digital Phosphor Oscilloscopes www tektronix com oscilloscopes P Tektronix Active probes achieve high speed signal acquisition and measurement fidelity With OpenChoice Software Customize Your Test and Measurement System with Familiar Analysis Tools The analysis and networking features of OpenChoice software add flexibility to Tektronix Windows XP oscilloscopes Using the fast
8. with Opt DVI RTE To upgrade DPO7000 Series with Opt RTE or TDSRT Eye software LSA To upgrade DPO7000 Series with Opt LSA JE3 To upgrade DPO7000 Series with Opt JES ET3 4 To upgrade DPO7000 Series with Opt ELS JA3 To upgrade DPO7000 Series with Opt JA3 USB To upgrade DPO7000 Series with Opt USB MTM To upgrade DPO7000 Series with Opt MTM PTM To upgrade DP07254 or DPO7354 with Opt PTM PWR To upgrade DPO7000 Series with Opt PWR CP2 8 TDSCPM2 ANSI ITU Telecom pulse compli ance testing software requires Opt MTM on DPO7000 Series J2 TDSDDM2 disk drive analysis software 1P Thermal printer 2 DP07254 or DP07354 only 3 DPO7054 and DPO7104 only 4 Requires Ethernet Test Fixture 5 Requires TDSUSBF USB Test Fixture 6 DP07354 only 7 Probe requires TPA BNC adapter 8 Requires Opt MTM Digital Phosphor Oscilloscopes www tektronix com oscilloscopes 15 Digital Phosphor Oscilloscopes gt DPO7000 Series Contact Tektronix ASEAN Australasia 65 6356 3900 Austria 41 52 675 3777 Balkan Israel South Africa and other ISE Countries 41 52 675 3777 Belgium O7 81 60166 Brazil amp South America 11 40669400 Canada 1 800 661 5625 Central East Europe Ukraine and the Baltics 41 52 675 3777 Central Europe amp Greece 41 52 675 3777 Denmark 45 80 88 1401 Finland 41 52 675 3777 France 33 0 1 69 86 81 81
9. you can set the desired encoded words for the serial pattern trigger to capture This serial trigger option covers NRZ serial standards up to 1 25 Gb s Triggering on an analog HDTV tri level sync signal and examining horizontal blanking interval Large 12 1 inch XGA Display Screen The DPO7000 Series has the largest display in the industry with a 12 1 inch XGA touch screen that gives up to 15 more waveform display than other oscilloscope series in its class Ten vertical divisions give you 25 more vertical measurement resolution Unmatched Usability The TekVPI probe interface provides versatility and ease of use enabled by intelligent bi directional oscilloscope to probe Communication The DPO7000 Series are fast responding instruments and contain a comprehensive suite of features such as a touch screen shallow menu structures intuitive graoh ical icons knob per channel vertical controls support for right mouse clicks mouse wheel improvements saving of waveforms and measurements available in Preview mode Export Save Recall menu improvements A Digital Phosphor Oscilloscopes www tektronix com oscilloscopes Serial pattern triggering to debug pattern dependent issues Interoperability with Logic Analyzers for Digital Design and Debug Tektronix Integrated View iView data display enables digital designers to solve signal integrity challenges and effectively debug and verify their syst
10. 16 1942 00 Transit Case with Wheels Order 016 1522 00 Video Display Clamp Order Order 013 0278 xx Rackmount Kit Order 016 1985 xx Oscilloscope Cart Order K420 requires 407 5192 00 bracket set Thermal Printer Paper Order 016 1969 00 Test Fixtures TDSUSBF Test fixture for use with Opt USB Probe Calibration Power Deskew Fixture Order 067 1686 00 Ethernet Test Fixture Order through Crescent Heart Software htto www c h s com Adapters AMT75 1 GHz 75 Q adapter P6701B Optical electrical converter multi mode P6703B Opticalelectrical converter single mode Digital Phosphor Oscilloscopes gt DPO7000 Series Instrument Upgrades To upgrade your DPO7000 Series Oscilloscope order option as noted DPO7UP with Opt RLO2 To upgrade record length from standard configuration to Opt 2RL configuration RLO5 To upgrade record length from standard configuration to Opt SRL configuration RLO10 To upgrade record length on DPO7254 or DP07354 from standard configuration to Opt 10RL configuration RL25 To upgrade record length from Opt 2RL configuration to Opt SRL configuration RL210 To upgrade record length on DPO7254 or DPO7354 from Opt 2RL configuration to Opt 10RL configuration RL510 2 To upgrade record length on DPO7254 or DPO7354 from Opt SRL configuration to Opt 10RL configuration DVI 8 To upgrade DPO7000 Series
11. Digital Phosphor Oscilloscopes gt DPO7000 Series Unmatched Performance for Greater Insight Into Your Design to Get Your Work Done Faster The DPO7000 Series are the new generation of real time digital phosphor oscilloscopes and are the industry s best solution to the challenging signal integrity issues faced by designers verifying characterizing debugging and testing sophisticated electronic designs The family features exceptional perform ance in signal acquisition and analysis operational simplicity and unmatched debugging tools to accelerate your day to day tasks The largest screen in the industry and the intuitive user interface provide easy access to the maximum amount of information Unmatched Acquisition Performance Signal Fidelity of Tektronix Oscilloscopes Ensures Confidence in Your Measurement Results gt High sample rate on all models on all chan nels to capture more signal details tran sients imperfections fast edges 40 GS s on one channel on the 2 5 GHz and 3 5 GHz models Option 2SR to double the maximum real time sample rate for the 500 MHz and 1 GHz models gt High bandwidth up to 3 5 GHz matched across 2 3 or 4 channels and enabled by Tektronix proprietary DSP enhancement The user selectable DSP filter on each channel provides magnitude and phase correction plus extension to 3 5 GHz for more accurate signal fidelity for complex measurements The DSP filter on each cha
12. Positive Overshoot Negative Overshoot Time Related Rise Time Fall Time Positive Width Negative Width Positive Duty Cycle Negative Duty Cycle Period Frequency Delay Combination Area Cycle Area Phase Burst Width Histogram Related Waveform Count Hits in Box Peak Hits Median Maximum Minimum Peak to Peak Mean u Standard Deviation 6 U 16 U 20 U 3o Eye Pattern Related Extinction Ratio absolute dB Eye Height Eye Width Eye Top Eye Base Crossing Jitter ok pk RMS 60 Noise pk pk RMS Signal Noise Ratio Cycle Distortion Q Factor Waveform Processing Math Arithmetic Add Subtract Multiply Divide Waveforms and Scalars Algebraic Expressions Define extensive algebraic expressions including Waveforms Scalars User adjustable Variables and Results of Parametric Measurements e g Integral CH 1 Mean Ch 1 x 1 414 x VARI Math Functions Average Invert Integrate Differentiate Square Root Exponential Log Log Abs Ceiling Floor Min Max Sin Cos Tan Asin ACos Alan Sinh Cosh Tanh Relational Boolean result of comparison gt lt lt Frequency Domain Functions Spectral Magnitude and Phase Real and Imaginary Spectra Vertical Units Magnitude Linear dB dBm Phase Degrees radians group delay IRE and mV units Window Functions Rectangular Hamming Hanning Kaiser Bessel Blackman Harris Gaussian Flat
13. ard deviation and population Define and apply math expressions to waveform data for on screen results in terms that you can use Access common waveform math functions with the touch of a button Or for advanced applications create algebraic expressions consisting of live waveforms reference waveforms math functions measurement values scalars and user adjustable variables with an easy to use Calculator style editor FFT To analyze your signal in the spectral domain use the basic spectral provides you with the best parameter or use the advanced spectral to directly control the frequency span center frequency and resolution bandwidth Filtering Enhance your ability to isolate or remove some important component of your signal noise or specific harmonics of the signal by creating your own filters or using the filters provided as standard with the instrument Digital Phosphor Oscilloscopes gt DPO7000 Series P Basic spectral Ul control window Digital Phosphor Oscilloscopes www tektronix com oscilloscopes 5 Digital Phosphor Oscilloscopes gt DPO7000 Series Jitter and Timing measurement A Breadth of Optional Packages to Extend Waveform Analysis Even Further Jitter and Timing Measurement and Analysis Package Opt JA3 or JE3 Tight timing margins demand stable low jitter designs This software option extends the oscilloscope capability by making jitter measurements over con
14. d feature and includes trig gering on a data pattern within a user definable frame RS 232 triggering is a standard feature CAN Controller Area Network triggering is an optional feature Opt LSA and includes synchronization to the Start or End of a CAN frame on any CAN high or CAN low signal triggering on Type of Frame Data Remote Overload Identifier Data Missing Acknowledge and Bit Stuffing error Digital Phosphor Oscilloscopes www tektronix com oscilloscopes 3 Digital Phosphor Oscilloscopes gt DPO7000 Series Easily trigger on a specific 1 C address Analog HDTV EDTV triggering for emerging standards like 1080i 1080p 720p and 480p as well as standard video triggering on any line within a field all lines all fields odd or even fields for NTSC SECAM and PAL video signals In addition IRE and mV graticules can be selected for easier measurements and visual inspection This is a standard feature To debug serial architectures use the serial pattern triggering option for NRZ serial data stream with built in clock recovery available on models DPO7254 and DPO7354 only The instrument can recover the clock signal identify the transitions and decode characters and other protocol data With the combination of the Serial Trigger and Protocol Decode software you can see the captured bit sequences decoded into their words for convenient analysis for 8b 10b and other encoded serial data streams or
15. ech nology to provide trigger sensitivity of up to the bandwidth of the instrument and allows selection of most trigger types on both A and B trigger circuits It can capture very narrow glitches with very little trigger jitter Other trigger systems offer multiple trigger types only on a single event A event with delayed trigger B event selection limited to edge type trig gering and often do not provide a way to reset the trigger sequence if the B event doesn t occur But Pinpoint triggering provides a full suite of advance trigger types on both A and B triggers with Reset triggering to begin the trigger sequence again after a specified time state or transition so that even events in the most complex signals can be captured Other oscilloscopes typically Digital Phosphor Oscilloscopes gt DPO7000 Series MET Isolate set up and hold violations down to 360 ps offer less than 20 trigger combinations Pinpoint triggering offers over 1400 combinations all at full performance Now you can even use a probe and the full functionality of the trigger system with the Auxiliary trigger input Trigger on the Most Relevant Bit Sequence of the Industry Standard Serial Bus 2C Inter Integrated Circuit triggering is a standard feature and includes Start condition Missing Acknowledge Restart Data Read Address and or Data Frame in a 10 bit or 7 bit format SPI Serial Peripheral Interface triggering is a standar
16. ems more quickly and easily This integration allows designers to view time correlated digital and analog data in the same display window and isolate the analog charac teristics of the digital signals that are causing systems failures No user cali bration is required And once set up the View feature is completely automated hig Tag Digis Cros ksa 12 7 inch display 15 16 larger than a 10 4 inch display 2 larger than a 6 3 inch display P How does 12 1 inch display compare to the display size of other oscilloscopes More Insight into Your Complex Electrical Design for Characterization and Compliance Testing Whether it s a simple math expression waveform mask testing a pass fail compliance test or a custom application that you develop the DPO7000 Series Oscilloscopes offer the industry s most comprehensive set of analysis and compliance tools A Wide Range of Built in Advanced Waveform Analysis Tools Waveform cursors make it easy to measure trace to trace timing character istics while cursors that link between YT and XY display modes make it easy to investigate phase relationships and Safe Operating Area violations Select from 53 automatic measurements using a graphical palette that logically organ izes measurements into Amplitude Time Combination Histogram and Communications categories Gather further insight into your measurement results with statistical data such as mean min max stand
17. eries P Basic spectral Ul control window Tektronix DPO 72 T T t 54 Digital Phosph r Oscilloscope intensi a m h Biop d Single Clear Feet fang Position Ropu Digital Phosphor Oscilloscopes gt DPO7000 Series gt Power measurement i Leyal Heiss FT isek TNI E EN l h T HEREe Ba Seaeee Scale r So wiog off SS SSS Ss pe Le chi Ch2 Ch3 Ch4 E E S E A es TE R e N Mun RL ote N Testing a 622 Mb s signal against the mask mime a Se berate a e SY ar HS meme eea r aeh h s a RL Scale Scale Scale Scale specified by the standard 25ns 40 0GS s 25 0psipt Sample 273 408 acgs September 09 2005 co Bec a rl M4 FE ee Lt aera LIH pi chiil Aerie Poet ar ae eee R RECOVERED RECOVERED DATA CLOCK PROBE CALIBRATION COMPENSATION Oa O LE Nes TTD 1 ys OT T Todea LT le i aS _ b B ir 1r pi g bl T k ia i i a sma ll Wit re P CAN and LIN Timing and Protocol Decode 1 Large 12 1 inch XGA Touch Screen Display The DPO7000 series touch screen gives up to 15 more waveform display than other oscilloscopes of its class 2 New Probe Interface TekVPI probe interface provides versatility and ease of use enabled by intelligent bi directional oscilloscope to probe communication Exceptional Performance The performance of the highest bandwidth oscil
18. ger Level Range Internal 12 divisions from center of screen AUX Trigger TekVPI interface 5 V 60 Q 150 V CAT derate at 20 dB decade to 9 V ays above 200 KHz 1 MQ Line Fixed at 0 V Trigger Couplin DC AC attenuates lt 60 Hz HF Rej attenuates gt 30 kHz LF Rej attenuates lt 80 kHz Noise Reject reduces sensitivi Trigger Holdoff Range 250 ns min to 12 s max Digital Phosphor Oscilloscopes www tektronix com oscilloscopes_ 11 Digital Phosphor Oscilloscopes gt DPO7000 Series Trigger Modes Edge Positive or negative slope on any channel or front panel auxiliary input Coupling includes DC AC noise reject HF reject and LF reject Glitch Trigger on or reject glitches of positive negative or either polarity Minimum glitch width is down to 170 ps typical with re arm time of 250 ps for DPO7254 or DPO7354 Width Trigger on width of positive or negative pulse either within or out of selectable time limits down to 225 ps Runt Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again Event can be time or logic qualified Timeout Trigger on an event which remains high low or either for a specified time period Selectable from 300 ps Transition Trigger on pulse edge rates that are faster or slower than specified Slope may be posi tive negative or either Setup Hold Trigger on violations of both setup time and hold t
19. h offset position set to 0 Hardware Bandwidth Limits 250 MHz or 20 MHz Input Coupling AC DC GND Input Impedance software 1 MQ 1 with 13 pF 2 pF or selectable 50 Q 1 Input Sensitivity 1 MQ 1 mV div to 10 V div 50 Q 1 mV div to 1 V div Vertical Resolution 8 bit gt 11 bit with averagin Max Input Voltage 1 MQ 150 V CAT derate at 20 dB decade to 9 Vixy above 200 kHz Max Input Voltage 50 Q 5 Vams With peaks less than 24 V Position Range 5 divisions Offset Range 1 mV div to 50 mV div 1 V 50 5 mV div to 99 5 mV div 0 5 V 100 mV div to 500 mV div 10 V 505 mV div to 995 mV div 5 V 1 V div to 5 V div 100 V 5 05 V div to 10 V div 50 V Offset Accuracy 1 mV div to 9 95 mV div 0 2 offset value position 0 1 div 1 5 mV 10 mV div to 99 5 mV div 0 35 offset value position 0 1 div 1 5 mV 100 mV div to 1 V div 0 35 offset value position 0 1 div 15 mV 1 01 V div to 10 V div 0 25 offset value position 0 1 div 150 mV Delay between any two lt 100 ps 50 Q DC coupling and equal V div at or above 10 mV div channels typical Channel to Channel Isolation gt 100 1 at lt 100 MHz any two channels at equal gt 30 1 between 100 MHz and 2 5 GHz vertical scale settings typical gt 20 1 between 2 5 and 3 5 GHz 1 3 GHz for sinewave of more than 4 div amplitude typically Digital Phosphor Oscilloscopes www tektronix com oscilloscopes 7 Digital Phosphor Oscilloscopes gt DPO7000 S
20. ime between clock and data present on any two input channels Pattern Trigger when pattern goes false or stays true for specified period of time Pattern AND OR NAND NOR specified for four input channels defined as high low or don t care State Any logical pattern of channels 1 2 3 clocked by edge on channel 4 Trigger on rising or falling clock edge Window Trigger on an event that enters or exits a window defined by two user adjustable thresholds Event can be time or logic qualified Trigger Delay by Time 5 ns to 250 s Trigger Delay by Events 1 to 10 000 000 events Comm Provided as part of Opt MTM Support for AMI HDB3 BnZS CMI MLT3 and NRZ encoded signals 12C SPI and RS 232 Protocol trigger on DP07054 DPO7154 DPO7254 or DPO7354 CAN Protocol trigger on DPO7054 DPO7154 DPO7254 or DPO7354 as part of Opt LSA Serial Pattern Captures serial data stream with built in clock recovery for NRZ standards up to 1 25 Gb s Opt ST 12 Digital Phosphor Oscilloscopes www tektronix com oscilloscopes Waveform Measurements Automatic Measurements 53 of which 8 can be displayed on screen at any one time measurement Statistics user definable reference levels measure ment within gates isolating the specific occurrence within an acquisition to take measurements on Amplitude Related Amplitude High Low Maximum Minimum Peak to Peak Mean Cycle Mean RMS Cycle RMS
21. ith Opt 2SR 10 GS s 20 GS s 3 to 4 Channels max 2 5 GS s 5 GS s 10 GS s With Opt 2SR 5 GS s 10 GS s Equivalent Time Sample Rate max 4 TS s for repetitive signals Maximum Record Length per Channel With Standard Configuration 40 M 1 CH 20 M 2 CH 10 M 4 CH With Record Length Opt 2RL 80 M 1 CH 40 M 2 CH 20 M 4 CH With Record Length Opt 5RL 200 M 1 CH 100 M 2 CH 50 M 4 CH With Record Length Opt 10RL 400 M 1 CH 200 M 2 CH 100 M 4 CH gt Maximum Duration at Highest Real time Resolution 1 CH DPO7054 DPO7104 DPO7254 DPO7354 Resolution 100 ps 10 GS s 50 ps 20 GS s 25 ps 40 GS s With Opt 2SR 50 ps 20 GS s 20 ps 40 GS s Max Duration with Standard Record 4 ms 2 MS 1 ms Length and Sample Rate With Opt 2SR 2 mS 1 ms Max Duration with Opt 2RL 8 ms 4 ms 2 mS With Opt 2SR 4 ms 2 MS Max Duration with Opt 5RL 20 ms 10 ms 5 ms With Opt 2SR 10 ms 5 ms Max Duration with Opt 10RL 10 ms 10 Digital Phosphor Oscilloscopes www tektronix com oscilloscopes Digital Phosphor Oscilloscopes gt DPO7000 Series Acquisition Modes DPO7054 DPO7104 DPO7254 DPO7354 FastAcg Acquisition Mode FastAcg optimizes the instrument for analysis of dynamic signals and capture of infrequent events Maximum FastAcg Waveform Capture Rate gt 250 000 wfm s on all 4 channels simultaneously Waveform Database Accumulate waveform database providing
22. loscope in a mid range offering with up to 40 GS s real time sample rate and 400 M record length on one channel With MultiView Zoom Easily deep into very long record of acquired data analyze multiple waveform segments simultaneously and scroll automatically through the deepest records visually 8 Digital Phosphor Oscilloscopes www tektronix com oscilloscopes 5 Unmatched Usability With MyScope create your own control window with only the controls you care about The versatile user interface allows you to use the touch screen or the mouse 6 Accelerate the Debug of Complex Designs with Pinpoint Triggering Access up to 1400 trigger combinations to address virtually any triggering Situations 7 FastAcq Acquisi tion Expedites Debugging by Clearly Showing Faults More than 250 000 waveforms per second and with a simple turn of the intensity knob clearly see the fre quency of occurrence 8 Easy Connectivity Built in USB port at the front to ease the saving of your work Most standard input output ports available on the side of the instrument 250VRMS I 9 A Wide Range of 10 For Insight into Built in Advanced Your Low speed Analysis Tools Serial Designs Cursors that link Serial Protocol between XY and YT Triggering for IC SPI 53 automatic CAN plus a complete measurements CAN and LIN timing and protocol analysis Many math functions software package
23. nnel can also be switched off to take advantage of true 2 5 GHz analog bandwidth for applications needing the highest available raw data capture Very low jitter noise floor and vertical accuracy for very accurate measurements gt Longest acquisition of the industry to provide more resolution and longer time sequence Standard 10 million data points per channel on the DPO7000 Series Optional up to 400 million total data points on 2 5 GHz and 3 5 GHz models Optional up to 200 million total data points on the 500 MHz and 1 GHz models Easily manage this deep record length provide detailed comparison and analysis of multiple waveform segments with the MultiView Zoom feature Automatically scroll through deep records visually or create a math expres sion to instantly highlight differences gt Highest performance probing solutions for differential and single ended voltage signals as well as current measurement because accurate design verification depends on high bandwidth access to critical signals and high fidelity signal capture gt Features amp Benefits 3 5 GHz Bandwidth Model for Serial and Digital Applications 2 5 GHz 1 GHz and 500 MHz Bandwidth Models for All Applications Up to 40 GS s Real time Sample Rate on One Channel and Up to 10 GS s on All Four Channels Up to 400 Megasamples Record Length with MultiView Zoom Feature for Quick Navigation gt 250 000 wfm s Maximum Waveform Ca
24. nt and Analysis Opt PWR Analyze power dissipation in power supply switching devices and magnetic components and generate detailed reports in customizable formats The HiRes acquisition mode delivers greater gt USB compliance testing than 8 bits of vertical resolution on single shot or repetitive signals at bandwidth up to 125 MHz The powerful and flexible measurements math and math on math Capabilities make it an ideal solution for performing power measurements such as voltage current instantaneous power and energy for power device designers The new TekVPI interface provides smart communication between the oscilloscope and the probe TekVPI probe interface also provides more power to the probe interface allowing customers to directly connect current probes to the front of the oscilloscope Optional Ethernet Opt ETS Provides compliance testing for 10 100 1000Base T signals Optional USB Opt USB Provides compliance testing for USB2 0 signals Digital Phosphor Oscilloscopes gt DPO7000 Series gt Characteristics gt Vertical System DPO7054 DPO7104 DPO7254 DPO7354 Input Channels 4 Bandwidth DSP Bandwidth N A N A N A 3 5 GHz Enhance Rise Time DSP Bandwidth 115 ps Enhance __ Hardware Analog 500 MHz 1 GHz 2 5 GHZ 2 5 GHZ Bandwidth 3 dB Rise Time 10 to 90 typical 460 ps 300 ps 160 ps 145 ps Rise Time 20 to 80 typical 310 ps 200 ps 100 ps 95 ps DC Gain Accuracy 1 wit
25. o 45 RH above 30 C up to 50 C Altitude Operating 10 000 ft 3 048 m Non operating 40 000 ft 12 190 m Random Vibration Operating 0 000125 G2 Hz from 5 to 350 Hz 3 dB octave from 350 to 500 Hz 0 0000876 G2 Hz at 500 Hz Overall level of 0 27 Grus Non operating 0 0175 G Hz from 5 to 100 Hz 3 dB octave from 100 to 200 Hz 0 00875 G2 Hz from 200 to 350 Hz 3 dB octave from 350 to 500 Hz 0 006132 G2 Hz at 500 Hz Overall level of 2 28 Garjs Regulatory Electromagnetic Compatibility 93 68 EEC EN61326 1997 A1 1998 A2 2000 Certifications UL 3111 1 CSA1010 1 IS011469 EN61010 1 IEC 61010 1 Digital Phosphor Oscilloscopes www tektronix com oscilloscopes 13 Digital Phosphor Oscilloscopes gt DPO7000 Series gt Ordering Information DPO7054 900 Mhz Digital Phosphor Oscilloscope DPO7104 1 GHz Digital Phosphor Oscilloscope DPO7254 2 0 GHz Digital Phosphor Oscilloscope All Models Include Accessory pouch front cover mouse quick start user manual 071 173x xx probe calibration and deskew fixture 067 0405 xx DPO7000 Series product software media DPO7000 series operating system restoration media optional applications software media performance verification procedure PDF file GPIB programmer s reference on product software media calibration certificate documenting NIST traceability Z 540 1 compliance and ISO9001 power cord one year warranty User
26. on
27. pture Rate MyScope Custom Windows Enhance Productivity Right Mouse Click Menus for Exceptional Efficiency Pinpoint Triggering Provides the Most Flexible and Highest Performance Triggering with Over 1400 Combinations to Address Virtually Any Triggering Situation Small Footprint and Light Weight 12 1 Largest XGA Touch Screen Display in the Industry Communications Mask Testing Clock Recovery from Serial Data Streams 64 Bit NRZ Serial Pattern Trigger for Isolation of Pattern dependent Effects Up to 1 25 Gb s Serial Pattern Triggering Low speed Serial Protocol Triggering 1 C SPI RS 232 CAN Technology specific Software Solutions Provide Built in Domain Expertise for Ethernet USB 2 0 Compliance Testing Jitter and Timing Measurements Power Measurements CAN and LIN Network Design OpenChoice Software with Microsoft Windows XP OS Enables Built in Networking and Extended Analysis Applications Signal Integrity Jitter and Timing Analysis Verification Debug and Charac terization of Sophisticated Designs Debugging and Compliance Testing of Serial Data Streams for Telecom and Datacom Industry Standards Low speed Serial Bus Design 2C SPI CAN LIN RS 232 Investigation of Transient Phenomena Power Measurements and Analysis Spectral Analysis Tektronix Enabling Innovation Digital Phosphor Oscilloscopes gt DPO7000 Series Zoom in on four areas of interest simultane
28. quency 1 kHz 5 Recovered Clock for DPO07254 or DP07354 only BNC connector lt 1 25 Gb s Output swing 130 MV kpk into 50 Q Requires option to enable Recovered Data for DPO07254 or DP07354 only BNC connector lt 1 25 Gb s Output swing 200 mV into 50 Q Requires option to enable USB 2 0 Port One USB 2 0 connector Aux Trigger Input See Trigger specification Side Panel Parallel Port IEEE 1284 DB 25 connector Audio Ports Miniature phone jacks disabled Keyboard Port PS 2 compatible Mouse Port PS 2 compatible USB Ports Four USB 2 0 connectors LAN Port RJ 45 connector supports 10Base I 100Base T and Gigabit Ethernet Serial Port DB 9 COM1 port VGA Video Port DB 15 female connector connect a second monitor to use dual monitor display mode Supports basic requirements of PC99 specifications Oscilloscope VGA Video Port DB 15 female connector 31 6 kHz sync EIA RS 343A compliant connect to show the oscilloscope display including live waveforms on an external monitor or projector Rear Panel Power 100 to 240 Vans 10 47 to 63 Hz lt 550 W 115 Ves 10 400 Hz CAT lt 500 VA Analog Signal Output BNC connector provides a buffered version of the signal that is attached to the Ch 3 input Amplitude 50 mV div 20 into a 1 MQ load 25 mV div 20 into a 50 Q load Bandwidth 100 MHz into a 50 Q load Software Switchable BNC Connector
29. rnet Compliance Test Software Opt USB TDSUSBS USB2 0 Compliance Test Software only Opt PWR DPOPWR Power Measurement and Analysis Software Opt RTE for DPO7254 7354 only 2 RT Eye Serial data compliance and analysis software Opt DVI for DPO7354 only Digital Visual Interface compliance test software Bundle Options Opt PS1 Power Bundle option includes TPA BNC adapter Probe Calibration and deskew fixture 067 1686 xx P5205 TCP0030 and Opt PWR 14 Digital Phosphor Oscilloscopes www tektronix com oscilloscopes User Manual Options Opt LO English manual Opt L1 French manual Opt L3 German manual Opt L5 Japanese manual Opt L7 Simplified Chinese manual Opt L8 Standard Chinese manual Opt L9 Korean manual Opt L10 Russian manual Power Plug Options Opt AO North America Opt A1 Universal European Union Opt A2 UK Opt A3 Australia Opt Ad Switzerland Opt A6 Japan Opt A10 China Opt A11 India Opt A99 No power cord Service Options Probes and accessories are not included in the oscilloscope warranty Refer to the data sheet for each probe for its unique warranty and calibration terms Opt C3 Calibration Service 3 years Opt C5 Calibration Service 5 years Opt D1 Calibration Data Report Opt D3 Calibration Data Report 3 years with Opt C3 Opt D5 Calibration Data Report 5 years with
30. three dimensional array of amplitude time and counts sample Acquire sampled values Peak Detect Captures narrow glitches at all real time sampling rates 1 ns at lt 125 MS s 1 sample rate at gt 250 MS s Averaging From 2 to 10 000 waveforms included in average Envelope From 1 to 2 x 10 waveforms included in min max envelope Hi Res Real time boxcar averaging reduces random noise and increases resolution FastFrame Acquisition Acquisition memory divided into segments maximum trigger rate gt 310 000 waveforms per second Time of arrival recorded with each event Roll Mode Up to 10 MS s with a maximum record length of 40 M gt Pinpoint Trigger System DPO7054 DPO7104 DP07254 DPO7354 Sensitivity Internal DC Coupled 0 7 div DC to 50 MHZ increasing to 1 2 div at rated analog bandwidth typical 2 5 div at 3 5 GHz with DSP Bandwidth enhance External auxiliary input 1 MQ 250 mV from DC to 50 MHz increasing to 350 mV at 250 MHz typical Trigger Characteristics A Event and Delayed B Event Trigger Types Edge Glitch Runt Width Transition Time Timeout Pattern State Setup Hold Window all except Edge Pattern and State can be Logic State qualified by up to two channels Low Speed Serial Protocol Trigger Type A Event only 2C SPI and RS 232 standard CANbus available as Opt LSA Trigger on address data and special handshaking states and other conditions Main Trigger Modes Auto Normal and Single Trigger Sequences Main Delayed b
31. tiguous clock cycles from every valid pulse in a single shot acquisition Multiple meas urements and trend plots quickly show system timing under variable conditions This analysis package is available as Opt JAS or Opt JE3 on the DPO7000 Series JES provides a subset of the measurements Communications Mask Testing Opt MTM This feature provides a complete portfolio of masks for verifying compliance to serial communications standards It supports 156 Standards Masks gt ITU T 64 Kb s to 155 Mb s gt ANSI 11 102 1 544 Mb s to 155 Mb s gt Ethernet IEEE 902 3 ANSI X3 263 125 Mb s to 1 25 Gb s gt Sonet SDH 51 84 Mb s to 622 Mb s gt Fibre Channel 133 Mb s to 2 125 Gb s gt USB 12 Mb s to 480 Mb s P IEEE 1394 491 5 Mb s to 1 966 Gb s P Rapidl O up to 2 Gb s P OIF Standards 1 244 Gb s P Video 143 18 Mb s to 1 485 Gb s 6 Digital Phosphor Oscilloscopes www tektronix com oscilloscopes gt Power measurement and analysis CAN and LIN Timing and Protocol Decode Software Opt LSA When you need to ensure seamless and reliable operation of a CAN or LIN network this option enables CAN bus triggering and provides the solution to measure oscil lator tolerance propagation delay and simultaneously decode CAN and LIN messages with the protocol leveraging the trigger capabilities This option is offered on DPO7354 DPO7254 DPO7104 and DPO7054 as Opt LSA Optional Power Measureme
32. to specify quick start user manual language and power plug when ordering DPO7054 also includes 4 P6139A 500 Mhz 10x passive probes Probes and accessories are not included in the oscilloscope warranty Refer to the data sheet for each probe for its unique warranty and calibration terms DPO7354 3 5 GHz Digital Phosphor Oscilloscope for Serial and Digital applications Options in gt Instrument Options Record Length Options Opt 2RL 80 MSamples max 20 MSamples ch Opt SRL 200 MSamples max 50 MSamples ch Opt 10RL for DPO7254 DP07354 only 400 MSamples max 100 MSamples ch Hardware Options Opt 2SR Double maximum real time sample rate Available for DPO07104 DP07054 only DPO7104 40 GS s 1 channel 20 GS s 2 channels 10 GS s 3 or 4 channels DP07054 20 GS s 1 channel 10 GS s 2 channels 5 GS s 3 or 4 channels Opt 1P Thermal printer in the pouch Printer option is available for all models Software Options Opt LSA Low Speed Serial Analysis includes CAN LIN Trigger Decode and Analysis Opt MTM Mask Testing for Serial Communication Standards up to 1 5 Gb s Includes hardware clock recovery on DPO7254 DP07354 Opt PTM for DP07254 DP07354 only 2 8b 10b protocol triggering and NRZ serial pattern triggering Includes hardware clock recovery up to 1 5 Gb s Opt JA3 TDSJIT3 Advanced Jitter Analysis Software Opt JE3 TDSJIT3 Essentials Jitter Analysis Software Opt Els TDSET3 Ethe
33. top2 Tek Exponential Waveform Definition As an arbitrary math expression Filtering Functions User definable filters Users specify a filter containing the coefficients of the filter Filter files provided Mask Function A function that generates a Waveform Database pixmap from a sample wave form Sample count can be defined Display Characteristics Display Type Liquid crystal active matrix color display Display Size Diagonal 307 3 mm 12 1 in Display Resolution XGA 1240 horizontal x 768 vertical pixels Waveform Styles Vectors Dots Variable Persistence Infinite Persistence Color Palettes Normal Green Gray Temperature spectral and User defined Display Format YT XY Computer System and Peripherals Operating System Windows XP CPU Intel Pentium 4 3 4 GHz processor PC System Memory 2 GB Hard Disk Drive Rear panel removable hard disk drive 80 GB capacity CD R W Drive Front panel CD R W drive with CD creation software application DVD Drive Read only Mouse Optical wheel mouse USB interface Printer optional Thermal printer fits in acces sories pouch provided with instrument Keyboard Order 119 7083 00 for small keyboard fits in pouch USB interface and hub Input Output Ports Front Panel Probe Compensator Output Front panel pins Amplitude 1 V 20 into a 50 Q load 500 mV from base to top into a 50 Q load fre
34. y Time Delayed by Events Reset by Time Reset by State Reset by Transition All sequences can include separate horizontal delay after the trigger event to position the acquisition window in time Communications related Triggers Requires Opt MTM Support for AMI HDB3 BnZS CMI MLT3 and NRZ encoded communications signals Select among isolated positive or negative one Zero pulse form or eye patterns as applicable to the standard Serial Pattern Trigger On DPO7254 or DPO7354 only and requires Opt PTM Up to 64 bit serial word recognizer bits specified in binary high low don t care or hex format Trigger on NRZ encoded data up to 1 25 Gb s Video Type Trigger Formats and Field Rates Triggers from negative sync composite video field 1 or field 2 for interlaced systems any field specific line or any line for interlaced or non interlaced systems Supported systems include NTSC PAL SECAM and HDTV 1080 24sF 1080p 25 1080i 50 1080i 60 1080p 24 720p 60 480p 60 Clock Recovery System On DPO7254 or DPO7354 only and requires Opt PTM or MIM Clock Recovery Phase Locked Loop Bandwidth Fixed at FBaud 500 Frequency Range 1 5 MBaud to 1 25 GBaud Clock Recovery Jitter RMS lt 0 25 bit period 5 PSpys for PRBS data patterns lt 0 25 bit period 5 PSpys for repeating 0011 data pattern typical Tracking Acquisition Range 5 of requested baud typical Minimum Signal Amplitude needed for Clock Recovery 1 div up to 1 25 GBaud typical Trig