Home

Adam Equipment CPWplus RANGE OF SCALES SERVICE MANUAL

image

Contents

1. Hod ec Manual hold function Hod 3 e Use the Tare Zero key to scroll through the options e f selection of Hod 2 or Hod 3 is made then it will lead to SETTING OF HOLD TIME LIMIT see section 13 1 9 The display will show Hold above the weight during operation Adam Equipment Company 2007 17 e lf Hod 1 is selected pressing the Unit key will take you back to the first parameter on Auto Power Off e f you want to return to weighing press the Print Hold key 7 1 9 SETTING OF HOLD TIME LIMIT e This parameter is to set the time limit by which the display is held after the hold function is used It is applicable if the hold function is set to Hod 2 or Hod 3 e Use the Tare Zero key to scroll through the options e The options are Fen ay ele era tr HO cis onde ae ap SOA oor Dee e Press the Unit key to confirm the selection and move back to the first parameter or press Print Hold to exit the parameter setting Adam Equipment Company 2007 18 HOLD AND PRINTING TABLE trn 1 trn 2 trn 3 Hod 1 RS 232 is off Prints continuously RS 232 prints when Hold is off Hold is off Print Hold is pressed Print hold key has Print hold key has no Hold function is disabled no function function Hod 2 RS 232 is off Print continuously RS 232 prints and hold Hold occurs Hold occurs automatica
2. press the Unit key which will advance to the next parameter e To return to normal weighing turn the scale off and back to on again or press the Print Hold key 7 2 1 FILTER This parameter is for setting the speed of the display filter For poor environments the filter should be set at its slowest to minimise external influences on the scale For weighing small samples or gradual filling the filter should be set at a faster setting p IL d M e Press Tare Zero to scroll through the options The display will show IT to Fi 3 If it is set to F T then the display is at its slowest setting and at Fl 3 the display is in its fastest setting e Press Unit to confirm the selection and move to the next parameter 7 2 2 ZERO TRACKING This parameter is for setting the range of the zero tracking Zero tracking will aid the scale to hold or return to zero and should be increased if large weights are left on the scale or temperature is not consistent ag o g e Press Tare Zero to scroll through the settings The display will show ZEo 1 to ZEo 8 If it is set to ZEo 1 the zero tracking is at its smallest range and ZEO 8 the highest e Press Unit to confirm the selection and move to the next parameter Adam Equipment Company 2007 20 7 2 3 STABILIZATION RANGE This parameter is for setting the range of the stability indicator This is used to determine when
3. it will stay on for 10 seconds after the scale returns to zero e Press the Unit key to confirm the selection and move to the next parameter Adam Equipment Company 2007 7 1 3 ENABLING OF UNITS e The third parameter is to enable or disable the weighing units so that the user can select the enabled units during the weighing operation Display will show on kg DEFAULT SET e Use Tare Zero to toggle between On and OFF Enables the unit orm kg a FF Disables the unit e Press the Unit key to confirm the selection and move to the next unit which is lb e After all units are set press the Unit key to move to the next parameter 7 1 4 COMMUNICATION ADDRESS e The fourth parameter is for setting the ID for the RS 232 results output Display will show Add 0 DEFAULT SET Add 0 e This parameter sets the communication address which is sent via RS 232 as an ID code There are 26 options to select from Add 0 to Add 25 Set Add 0 for no address The numbers relate to alphabets for example 1 A 2 B to 25 Y e Use the Tare Zero key to scroll through the options e Press the Unit key to confirm the selection and move to the next parameter Adam Equipment Company 2007 15 7 1 5 SELECTION OF BPS e The fifth parameter is to select the BPS or baud rate per second which is the speed of sending data to RS 232 interface Display will show 5 96
4. the scale on calibration or any other functions If the error message is still shown contact your supplier for further support Adam Equipment Company 2007 8 4 0 CONSTRUCTION The CPWplus range of Platform Scales has a stainless steel top pan on a steel frame and an indicator with a large backlit LCD The water resistant keyboard has 4 easy to use function keys On Off Print Hold Unit and Tare Zero All scales are supplied with the Power Supply module The construction of the scales includes an indicator housing with the electronics amp keypad and a base assembly with 4 load cells and a battery housing There are no user serviceable parts on the PCB or the base assembly If problems occur check the cable connecting the base to the indicator for cuts broken wires or poor soldering around the connections Likewise if a problem is found with the load cells check the wiring The load cells are not sold separately The simple indicator has no user serviceable parts There is no adjustment needed as it is designed to work with any of the CPWplus scale bases If the overlay fails replacements are available If the indicator is required to be opened to check connections replace the cable or change the software This can be done by removing the four screws of the right side plastic end cap The overlay will need to be removed above the four buttons so that the switch caps can be removed to allow the PCB to slide out Th
5. the scale will print automatically as well as indicate that the weight is stable v N Ka M e Press Tare Zero to scroll through the settings The display will show SIAT to SIA 8 If it is set to StA 8 then the stability is at its fastest and SA 1 the slowest e Press Unit to confirm the selection and move to the next parameter 7 2 4 STABILIZATION TRACKING This parameter is for setting the size of the tracking range to indicate the stability This is used to stable the scale once a weighing result is achieved SS l LI A beet M e Press Tare Zero to scroll through the settings The display will show Str T to Str o If it is set to Str T then the stability range is at its smallest and Str 5 the highest e When the desired value is displayed press the Print Hold key to select the value and exit the Technical Parameters The display will count down to zero and the scale will return to normal weighing e If Unit is pressed instead of the Print Hold key the display will ask for Pin for entering into the Factory Parameters Switch off the scale e Switch on the scale to start the operation Adam Equipment Company 2007 21 7 3 FACTORY PARAMETERS If after the last Technical Parameter Unit key is pressed the scale will advance to the Factory Parameter section This section contains critical calibration reference information and is protected by a Pin Cod
6. with the scales that is not directly addressed by this manual then contact your dealer or Adam Equipment for more assistance In order to provide further assistance the supplier will need the following information which should be kept ready A Details of your company Name of your company Contact person s name Contact telephone e mail fax or any other methods Details of the unit purchased This part of information should always be available for any future correspondence We suggest you to fill in this form as soon as the unit is received and keep a print out in your record for ready reference Model name of the scale CPW plus Serial number of the unit Software revision number Displayed when power is first turned on Date of Purchase Name of the supplier and place C Brief description of the problem Include any recent history of the unit For example Has it been working since it s delivered Has it been in contact with water Damaged from a fire Electrical Storms in the area Dropped on the floor etc Adam Equipment Company 2007 6 2 0 TROUBLE SHOOTING GUIDE PROBLEM Display is blank No turn on test Display all zeros after turn on AANA N appears on display Display is unstable Weight value incorrect Cannot use Full Capacity Not Linear Off Centre Loading error Adam Equipment Company 2007 POSSIBLE CAUSE Power Switch is fa
7. 00 DEFAULT SET e Use the Tare Zero key to scroll through the options e There are three options b 2400 b 4800 b 9600 e Press the Unit key to confirm the selection and move to the next parameter 7 1 6 SELECTION OF BIT RATE AND PARITY e The sixth parameter is to select the bit rate and parity used for sending data to RS 232 interface Display will show PAr DEFAULT SET 11 8 bits no parit PAr TI SS 7 bits even parity PR o 7 bits odd parity BB 3 e Use the Tare Zero key to scroll through the options e Press the Unit key to confirm the selection and move to the next parameter Adam Equipment Company 2007 16 7 1 7 SELECTION OF TRANSMISSION MODE e The seventh parameter is to select the transmission mode Display will show tm 1 DEFAULT SET See the HOLD AND PRINTING TABLE in section 13 1 9 Eee 5 7 No data output kean 1 Continuous data output GE Normal output when the Eee a Print Hold key is pressed e Use the Tare Zero key to scroll through the options e Press the Unit key to confirm the selection and move to the next parameter 7 1 8 SELECTION OF HOLD FUNCTION e The eighth parameter is to set the Hold function Display will show Hod 1 DEFAULT SET See the HOLD AND PRINTING TABLE in section 13 1 9 No hold function Hod Automatic hold function
8. EEA DAM Adam Eguipment CPW plus RANGE OF SCALES SERVICE MANUAL ADAM EQUIPMENT CO LTD P N 7950 Rev A3 August 2007 Adam Equipment Company 2007 Adam Equipment Company 2007 CONTENTS 10 INTRODUC TON ee 4 a Ke E KE 5 1 2 SERVICE INFORMATIONS sad oko ENEE kr t 6 210 TROUBLE SHOO TING GUIDE sudu i sav a ko ka o n 7 30 ERROR MESSAGES auaha oD OKA NZ 8 40 del ee ees 9 5 0 REPLACEMENT PARTS AND ACCESSORIES een 11 60 GALIBRATION sisieiriius rss raru ukuzi nu a E TAE 12 K WEN Ge la GE 13 l USERPARAMETER OD O A 13 7 1 1 AUTO POWER OFF rss ia ak ddd aei KA ka a 14 ZAZ a E OF TEE ME 14 7 1 3 ENABLING OF UNITS b sobi aa tae bono hok rot tro 15 7 1 4 COMMUNICATION ADDRESS o ee eeeneeeeeeenneeeeeeeeneeeeeee 15 Folio SELECTION OP BPS ao so out aso Vaha 16 7 1 6 SELECTION OF BIT RATE AND PARITY AA 16 7 1 7 SELECTION OF TRANSMISSION MODE eee 17 7 1 8 SELECTION OF HOLD FUNCTION east eass enoeiacoes aa 17 7 1 9 SETTING OF HOLD TIME LIMIT sss oko r no kasu backo 18 7 2 TECHNICAL PARAMETERS eee eee eee eee 19 7 2 1 PIE E 20 T22 LERO Eeer 20 2 5 STABILIZATION RANGE pata tot eisti ia 21 7 2 4 STABILIZ TION TRACKING 2 n por noha g E 21 4 0 FACTORY PARAMETER tatintinsaiiciiaictiaciaaeiai aclaaidalaalaitaut tes 22 8 0 TYPICAL EXPLODED VIEW cia Costa a a ea a oh 24 Adam Equipment Company 2007 1 0 INTRODUCTION The CPWplus range of scales are primarily used for general
9. e base can be accessed by removing the 4 nuts and washers on the top of the base plate under the weighing pan The nuts tighten only on the 5mm plastic spacer that passes through the pan so that the pan can sit on top of the load cell mountings without connecting them rigidly Inside the base are four full bridge load cells which are terminated to a PCB which includes voltage rectification and regulation plus an input from the external battery chamber on the underside of the base Adam Equipment Company 2007 9 All load cells are matched and are soldered to a common connection so there is no adjustment for off centre loading lf a load cell is to be measured using a DVM to check for damage then the signal wires must first be disconnected from the others to avoid measuring the average voltage of the whole system LOAD CELL WIRE CONNECTIONS Red Wire Ex 5V DC Black Wire Ex OV GND Green Wire Sig White Wire Sig OTHER CONNECTIONS The input voltage to the base is from a 12V AC adapter which is then rectified by four diodes and smoothed by electrolytic capacitor before being regulated to 9V DC for output via 7 pin audio connector to the weighing indicator Alternatively 6 x 1 5V Dry cell batteries can be used for standard CPWplus and CPWplus P only which connect via a protection diode to the same point Connections on the circular 8 pin audio base connector are Pin 1 TXD Transmit data via RS232 Pin 3 of 9 pin D conn
10. e which can only be accessed by a qualified technician To exit the user must switch off the scale when the display shows Pi Si Pi To proceed through the factory parameters follow the procedure as below e When the display shows Pi enter the pin code simply by pressing the Print Hold Tare Zero and Unit keys in this order The display will show a dash for each entry e Press Unit to enter the factory parameter settings The display will show the capacity and units e Press the Unit button to select the required factory calibration units e Press Tare Zero to select the desired maximum capacity to match the capacity of the weighing base e Press Print Hold to proceed to factory calibration The display will show L 00 with the left zero flashing e Press Tare Zero to scroll down the flashing digit and Print Hold to move to the next digit until the calibration mass value is displayed This should be as near to maximum capacity as possible and not less than 10 of the scale capacity e Press Unit to enter the value and display the raw ADC counts Verify that the counts look correct and increase by a linear value when loaded to maximum The ADC counts can vary between different models however typically the no load count value is between 2000 and 5000 counts When loaded to maximum the ADC count value should increase by approximately 20 000 if the correct base is being used Adam Equi
11. ector Pin 2 RXD Receive data via RS232 Pin 2 of 9 pin D con Pin 3 Load cell Sig of base PCB Load cell White wire Pin 4 Load cell Sig of base PCB Load cell Green wire Pin 5 Load cell Ex of base PCB Load cell Black wire Pin 6 Load cell Ex of base PCB Load cell Red wire Pin 7 DC supply to indicator 7809 output battery ve Pin 8 Voltage ground RS232 GND 7809 GND Pin 5 of 9 pin Adam Equipment Company 2007 10 5 0 REPLACEMENT PARTS AND ACCESSORIES If you need to order any accessories and spare parts contact your dealer or Adam Equipment A partial list of such items is as follows Accessories Part Number Hard carry case CPW plus models only 7954 Printer 8023 RS 232 cable 9014 Non slip mats For CPWp us L models only 9013 Spare Parts Part Number Power Supply Adapter 7973 Keypad overlay 7960 Stainless Steel Pan for CPWplus 8 CPWplusP 7972 Stainless Steel Pan for CPWplusW A 9011 CPW plus M Stainless Steel Pan for CPW plus L 9010 Replacement Lead Acid Battery for 9012 CPWplusW CPWplusM A CPW plus L Adam Equipment Company 2007 11 6 0 CALIBRATION e Occasionally the scale should be verified whether it is weighing correctly by measuring to a known mass e Zero the scale Place the mass on the centre of the platform and note the reading Calibrate the scale if necessary PROCEDURE e While in the normal weighing mode press and hold the Tare Zero key f
12. fill England and Wales Regulations 2002 and Hazardous Waste Regulations 2005 Battery recycling has become topical and the Waste Electrical and Electronic Equipment WEEE Regulations are set to impose targets for recycling Adam Equipment Company 2007 ADAM EQUIPMENT is an ISO 9001 2000 certified global company with more than 35 years experience in the production and sale of electronic weighing equipment Adam products are predominantly designed for the Laboratory Educational Medical retail and Industrial Segments The product range can be described as follows Analytical and Precision Balances Compact and Portable Balances High Capacity Balances Moisture analysers balances Mechanical Scales Counting Scales Digital Weighing Check weighing Scales High performance Platform Scales Crane scales Medical Scales Retail Scales for Price computing For a complete listing of all Adam products visit our website at www adamequipment com Copyright by Adam Equipment Co Ltd All rights reserved No part of this publication may be reprinted or translated in any form or by any means without the prior permission of Adam Equipment Adam Equipment reserves the right to make changes to the technology features specifications and design of the equipment without notice All information contained within this publication is to the best of our knowledge timely complete and accurate when issued However we are not
13. fus W CPWpfus M CPWpfus L Platform size 300 x 300 mm 11 8 x 11 8 j j 500 x 500 mm v V 19 7 x 19 7 900 x 600 mm 9 35 4 x 23 6 Power Option 12 VAC 150 mA Power supply v v v v v module supplied 6 x AA size batteries v M Internal rechargeable y A m battery 60 hours Net weight 4 kg 8 8 Ib k 5 25 kg 11 6 Ib k 10 5 kg 23 1 Ib k 8 5 kg 18 7 Ib v 17 kg 37 4 Ib v Indicator Dimensions wxdxh 270 x 80 x 30 mm 10 6 x 3 1 x 1 2 Stabilization time 2 3 seconds Tare Full range tare by subtraction Weighing units kg Ib oz Ib oz Calibration Automatic External user selectable cal weight Interface Bi directional RS 232 Operating temperature 0 to 40 C 32 F to 104 F Humidity Up to 90 RH non condensing 25 mm 1 0 Backlit LCD digits Display with weight legends for kg Ib oz Ib oz and low battery stable zero net weight and Hold symbols Keypad Mechanical switches under overlay Scale housing Indicator Aluminium Platform Mild steel base and stainless steel pan Applications Weighing Dynamic Animal weighing Display Hold NOTE CPWplus 6 CPWplus 15 and CPWp us P versions are available only in the USA Adam Equipment Company 2007 5 1 2 SERVICE INFORMATIONS Refer to the Operators Manual for details of operation This manual will cover details of calibration and troubleshooting If you have a problem
14. his eguipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the eguipment is operated in a commercial environment The eguipment generates uses and can radiate radio freguency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this eguipment in a residential area is likely to cause harmful interference in which case the user will be reguired to correct the interference at his own expense Shielded interconnect cables must be employed with this eguipment to insure compliance with the pertinent RF emission limits governing this device Changes or modifications not expressly approved by Adam Eguipment could void the user s authority to operate the eguipment WEEE COMPLIANCE ay Sealed Lead Acid r Battery Si s Must be recycled Properly Any Electrical or Electronic Eguipment EEE component or assembly of parts intended to be incorporated into EEE devices as defined by European Directive 2002 95 EEC must be recycled or disposed using techniques that do not introduce hazardous substances harmful to our health or the environment as listed in Directive 2002 95 EC or amending legislation Battery disposal in Landfill Sites is more regulated since July 2002 by regulation 9 of the Land
15. lly occurs automatically when automatically when when the weight is stable the weight is stable the weight is stable Hold is released if Print Hold key is Hold is released if Print Hold is pressed or pressed print will occur Print Hold is time expires as per Hti again pressed or time setting Hold function is released if expires as per Hti the key is pressed again setting or time expires as per Hti setting Hod 3 RS 232 is off Print continuously RS 232 prints and the Hold occurs when the Hold occurs when the hold occurs when Print Hold key is Print Hold key is Print Hold is pressed pressed pressed If Print Hold is pressed Hold is released if Hold is released if a second time print will Print Hold is Print Hold is pressed occur again pressed again or time again or time expires as Hold is released if expires as per HU per H setting Print Hold is pressed setting again or time expires as per Hti setting 7 2 TECHNICAL PARAMETERS The technical parameters allow adjusting of the scale for accuracy and speed See section 18 0 for the complete list of parameters e Switch off the scale e Hold the Unit key and then press On Off momentarily Release the Unit key The display shows the first technical parameter to set the filter FI X e To exit the parameter setting at any time press the Print Hold key Adam Equipment Company 2007 19 e To scroll through the technical parameters
16. or 4 seconds e The display will show GAL along with the last selected unit The unit can be changed by using the Unit key to calibrate in kg or Ib SE Et e Press the Print Hold key The display will show L M where XX is the Calibration weight which is user selectable A L g I kg e Use the Tare Zero key to change the flashing digit and the Print Hold key to move to the next digit e Press the Unit key to confirm the calibration weight The digit stops flashing Note If the selected mass is less than 10 of the capacity of the scale an error message GALEr will be displayed and the scale will return to zero Repeat the process correctly Adam Equipment Company 2007 12 Place the correct calibration mass as selected by the user at the centre of the pan Press the Unit The display will return to weighing mode Note If the mass loaded is more than 20 of the factory calibration reference then an error message GALEr will be displayed and the scale will return to weighing without calibration being saved Repeat the process correctly Remove the weight Verify the scale is calibrated correctly Repeat the process if necessary 7 0 PARAMETERS 7 1 USER PARAMETERS The scale can be set as desired by the user to control the weighing operation See section 18 0 for the complete list of parameters Switch off the scale Hold the Tare Zero key and then press
17. pment Company 2007 22 e With no mass on the pan press Unit The display will show LOAd and will return the ADC counts e Put the calibration mass entered earlier on to the pan and press Unit The factory calibration is completed and the scale returns to normal weighing It is now possible for the user to perform calibration at any point above 10 of the scale capacity However the new calibration must be less than 20 error from the factory calibration at the same mass or an error will be shown and calibration will be void Adam Equipment Company 2007 23 8 0 TYPICAL EXPLODED VIEW NUMBER PARTS QUANTITY NUMBER PARTS QUANTITY 3 Display case 1 11 Steel ball 4 cap 4 Slide cover 2 12 Steel ball 4 fixing structure 5 Indicator 1 13 Base steel 1 bracket ring 6 Base to 1 14 Sealed ring 1 Indicator Cable 7 Large screw 2 15 Pan Holder 1 8 Load cell holder 8 16 Pan with 1 dent 9 Steel ball 4 20 Foot 4 10 Steel ball cover 4 24 Panel 1 Adam Equipment Company 2007 24 CE Manufacturer s Declaration of Conformity This product has been manufactured in accordance with the harmonised European standards following the provisions of the below stated directives Electro Magnetic Compatibility Directive 89 336 EEC Low Voltage Directive 73 23 EEC Adam Eguipment Co Ltd Bond Avenue Denbigh East Milton Keynes MK1 1SW United Kingdom FCC COMPLIANCE T
18. responsible for misinterpretations which may result from the reading of this material The latest version of this publication can be found on our Website www adamequipment com Adam Equipment Company 2007
19. the On Off key momentarily Release the Tare Zero key The display shows the first parameter auto power off To exit the parameter setting at any time press the Print Hold key To scroll through the user parameters press the Unit key which will advance to the next parameter To return to normal weighing turn the scale off and back to on again or press the Print Hold key Adam Equipment Company 2007 13 7 1 1 AUTO POWER OFF e The first parameter is to set the auto power off function The display will show Pr OFF DEFAULT SET e Press Tare Zero to toggle between Pr on and Pr OFF Pr on Enables the Auto Power Off function The power will be turned off after 2 minutes if a key has not been pressed for 2 minutes and the scale is at zero lf there is any weight on the scale or a key is pressed the scale will continue to work Disables the Auto Power Off function Pr ot I The scale will not automatically turn off e Press the Unit key to confirm the selection and move to the next parameter 7 1 2 SETTING OF BACKLIGHT e The second parameter to set the backlight function Display will show BL 3 DEFAULT SET e Press the Tare Zero key to change the settings Off backlight is switched off always bL Li A On backlight is set to on always ik 3 Automatic backlight will be off unless a weight is placed on the pan When the weight is removed
20. ulty or not turned on Batteries are spent Power supply is incorrect Pan not installed Unstable weight Load cell damaged Electronics faulty Maximum capacity exceeded Load Cell damaged Electronics is faulty Drafts or air currents Obstruction under pan Sample is moving animal weighing Vibrations through table Temperature changed dramatically Electronics faulty Battery low Calibration error Recalibrate Unit calibrated with inaccurate weight Balance not level Obstruction between sample and cover Wrong unit of weight displayed Over load Stops hitting pan support or hitting bottom of load cell Electronics faulty Parameters set incorrectly Load Cell Damaged Overload stops hitting too soon Faulty Factory Calibration Overload Stops not correct Obstruction under pan 3 0 ERROR MESSAGES During the initial power on testing or during the operation the scale may show an error message The error messages are described below ERROR CODE DESCRIPTION A continuous beep is nnnnnn heard If the selected mass is less than 10 or more CALEr than 20 of the capacity of the scale an error message CALEr will be displayed and the scale will return to zero POSSIBLE CAUSES Weight on the pan exceeds the capacity of the scale Remove the weight from the pan Incorrect calibration mass Repeat the process correctly If an error message is shown repeat the procedure that caused the message such as turning
21. weighing applications The scales are used in different countries and can display weights in various units CPW plus 300 x 300mm 12 x 12 base operates with 6 x AA size batteries CPW plus M A Available in USA only 300 x 300mm 12 x 12 base operates with 6 x AA size batteries CPWp s W F 500 x 500mm 19 7 x 19 7 base with internal rechargeable batteries CPWplusL 900 x 600mm 35 4 x 23 6 base with internal rechargeable batteries 500 x 500mm 19 7 x 19 7 base with internal rechargeable batteries wheels and handles for moving Adam Equipment Company 2007 4 1 1 SPECIFICATIONS CPW plus 35 CPW plus 75 CPW plus 150 CPW pilus 200 CPW plus 35P CPWplus75P CPWplus 150P CPWp us 200P CPW plus35W CPWplus75W CPWpfus150W CPWpfus 200W CPWplus35M CPWp us 75M CPWpfus150M CPWpfus 200M CPW plus 35L CPW plus 75L CPW plus 150L CPWplus 200L Capacity 6kgx2g 15kgx5g 35kgx 10g 75 kg x 20g 150 kg x 50g 200 kg x 50 g X 13 Ib x 33 b x 75 lb x 0 02 b 165 lbx 0 05 Ib 330 Ib x 0 1 Ib 440 Ib x 0 1 Ib Readabi 0 005 lb 0 01 Ib 1200 oz 2640 oz 5280 oz 7040 oz lityd e 2120z 520 oz x 0 5 oz x1 0z X 202 X 2 0Z x 0 102 x 0 2 oz 74 Ib 16 oz 164 Ib 16 oz 329 Ib 16 oz 439 Ib 16 oz 13 Ib 1 oz 32 x1 oz x1 oz X2 oz X2 02 x1 0z Ib 160z x 1 oz bility 0 005 Ib 0 01 Ib gt Series CPWp s CPWplus P CPWp