1. The locking pedal must be in the neutral position see Fig 13 pedal is up against the stop at the top The locking pins must be fully extended see Fig 14 item 1 The locking mechanism must be in the forward position neutral position 4 Secure the screw connections of the locking mechanism linkage so it is free of tension without pushing or pulling straight in one plane Use suitable slotted holes in order to do so 5 Tighten the Allen head screws to a torque of 8 Nm Testing the locking mechanism Carry out a functional test after assembly is complete Note the following e he locking pins must fully engage in the locking plate Reference point the locking pins protrude slightly from the locking plate see Fig 14 item 1 e It must be possible to depress the locking pedal to the stop without a lot of force The mechanism unlocks com pletely in this process Reference point the locking pins are recessed 1 2 mm in the plastic locking mechanism housing 14 01 2012 f f CA Bocha Adjustments 6 8 Adjusting the Footrests Footplates A CAUTION Improper footrest footplate settings Risk of falling tipping over gt After changing the footrest footplate settings verify that the footrests footplates do not collide with the caster wheels at any of the seat tilt settings seat inclination The minimum distance between the footrest footplate and the caster wheel should be 25 mm gt Note that with certain foot
2. Otto Bock Alg rie E U R L 32 rue Ahc ne Outaleb Coop rative les Mimosas Mackle Ben Aknoun Alger DZ Alg rie Phone 213 21 913863 Fax 213 21 913863 e mail information ottobock fr www ottobock fr Otto Bock Egypt S A E 28 Soliman Abaza St Mohandessein Giza Egypt Phone 202 330 24 390 Fax 202 330 24 380 e mail info ottobock com eg www ottobock com eg Otto Bock South Africa Pty Ltd Building 3 Thornhill Office Park 94 Bekker Road Midrand Johannesburg South Africa Phone 27 11 312 1255 e mail info southafrica ottobock co za www ottobock co za Americas Otto Bock Argentina S A Av Cabildo 924 CP 1426 Ciudad Aut noma de Buenos Aires Argentina Phone 54 11 4706 2255 Fax 54 11 4788 3006 e mail atencionclientes ottobock com ar www ottobock com ar Otto Bock do Brasil Ltda Rua Jovelino Aparecido Miguel 32 13051 030 Campinas S o Paulo Brasil Phone 55 19 3729 3500 Fax 55 19 3269 6061 e mail ottobock ottobock com br www ottobock com br Otto Bock HealthCare Canada 5470 Harvester Road Burlington Ontario L7L 5N5 Canada Phone 1 289 288 4848 Fax 1 289 288 4837 e mail infocanada ottobock com www ottobock ca Otto Bock HealthCare Andina Ltda Clinica Universit ria Telet n Autopista Norte km 21 La Caro Chia Cundinamarca Bogot Colombia Phone 57 1 8619988 Fax 57 1 8619977 e mail info ottobock com co www ottobock com co Otto Bock de Mexico S A de
3. 2012 5 Safy Ho Bock 3 Safety 3 1 Explanation of Warning Symbols Warnings regarding possible risks of severe accident or injury Warnings regarding possible risks of accident or injury NOTICE Warnings regarding possible technical damage 3 2 General Safety Instructions Z WARNING Incorrect settings Risk of falling tipping over or improper user posture gt Adjustments may be carried out only by qualified personnel instructed by Otto Bock gt Only the settings described in these instructions for use may be carried out gt Settings may only be changed within the allowable adjustment ranges otherwise the stability of the product may be impaired see this chapter and the chapter Appendixes Please contact Otto Bock if you have any ques tions Only conduct tests in the presence of an assistant Unless expressly described you should not change any settings with a person sitting in the product Secure the user against falling out during all tests Activate the anti tipper during all tests Before testing setting changes with the user seated firmly tighten all screw connections Check for safe function before handing over the product Z WARNING Lack of instruction Risk of falling tipping over gt Instruct the user in the proper use of the product when handing it over gt Otto Bock recommends the preparation of an acceptance protocol A CAUTION vVVVVYV Wearing unsuitable work clothing Risk of pi
4. br 8127 NC SS crio od 21 BN E uice Boro ic rodeos 21 4 01 2012 OMe Pode Foreword 1 Foreword INFORMATION Date of the last update 2012 01 20 gt Please read this document carefully gt Follow the safety instructions INFORMATION Missing instructions for use can be downloaded from the homepage at www ottobock com or ordered directly from Otto Bock Service see back cover or inside back cover for addresses The product was delivered as specified on the order form Settings must be adjusted and the product must be fine tuned according to the medical indications or the needs of the user this must be done in the presence of the user These instructions for use provide the information necessary for adjusting the settings Adjustments should be made in close cooperation with the user or attendant Please note the following e The Instructions for Use Authorised Personnel are intended only for qualified authorised personnel and remain with them e The operation of the product is described in the Instructions for Use User These instructions must be given to the user or attendant e We recommend checking the product settings regularly in order to assure optimal fit over the long term A fitting is required every six months for children and youth in particular e The installation refitting of all optional components is generally described in the service manual e Otto Bock assumes no liability for combinations with seati
5. clamping screws on the seat plate supports see Fig 11 ttem 1 3 Slide the seat plate supports to the desired position Ensure that the seat plate supports are distributed as evenly as possible on the cross tubes 4 Tighten all clamping screws of the seat plate supports to a torque of 10 Nm 5 Tighten all seat plate mounting screws to a torque of 10 Nm 6 5 3 Installing Otto Bock Back Systems Option This option may only be installed by Otto Bock at this time 6 5 4 Installing other Seating Systems Back Systems In principle it is possible to install third party seating systems back systems on the product In this case liability rests with the authorised personnel that completed the installation Installation by Otto Bock Custom Fabrication is possible with a separate order Otto Bock assumes no liability for combinations with seating systems that have not been approved by Otto Bock see Page 21 6 6 Adjusting the Seat Height A CAUTION Installation without an assistant Pinching on components damage to the seat gt Always get help from an assistant to adjust the seat height The seat height can be modified adapted if necessary e g to obtain more ground clearance for the footplates because of long lower legs 1 Remove the locking mechanism linkage see Page 14 2 Loosen 2 x Allen head screws on both sides between the seat frame and main frame see Fig 12 item 1 Have the assistant hold the seat during thi
6. possible for the attendant For transfemoral amputees shift the seating centre of gravity forward This improves the stability of the wheel chair Do not reach into the adjustment mechanism when changing the seat tilt settings Checking the seating centre of gravity is required in order to ensure that the seat angle can be adjusted easily when the user is seated In principle the centre of gravity adjustment has the following effects Seating centre of gravity Effect Too far in front of the pivot point Seat tilts far forward when it is unlocked high holding torces required during seat adjustment 01 2012 15 Adjustments o Bocha Seating centre of gravity Effect S Too far behind the pivot point Seat tilts far backward when it is unlocked high holding torces required during seat adjustment Setting recommendations The seating centre of gravity should be individually adjusted according to the clinical picture The authorised personnel has to decide whether it is better that the seat swings forward or backward when no holding force is applied while the locking mechanism is released If possible the attendant who will later push the wheelchair should be consulted here Setting the seating centre of gravity 1 Loosen 3 x clamping screws on each of the seat adapters on both sides see Fig 17 item 1 see Fig 18 item 2 2 Only if necessary loosen the seat plate supports if they obstruct the adjustment of the seat adap
7. 0 Nm 6 Proceed the same way on the other side 6 5 Adaptation of the Seating Shell Seating System 6 5 1 Installing a Seating Shell Otto Bock Shape System Option This option may only be installed by Otto Bock at this time 6 5 2 Removing Installing a Seat Plate Option INFORMATION The preinstalled seat plate can continue to be used within the approved adjustment range For removal installation within the scope of adjustments or retrofitting a new seat plate complete the following steps a Removal installation to adjust the width of the seat frame 1 Loosen all mounting screws countersunk head screws between the seat plate and seat plate supports see Fig 10 item 1 2 After adjusting the frame width see Page 10 position the seat plate The front of the seat plate is flush with the front of the lateral tubes of the seat frame see Fig 10 item 2 The seat plate is centred between the lateral tubes of the seat frame 12 01 2012 f f CA Bocha Adjustments 3 Tighten all mounting screws to a torque of 10 Nm b Removal installation to adjust the seating centre of gravity To adjust the seating centre of gravity see Page 15 it may be necessary to shift the seat plate supports if they impede the adjustment of the seating centre of gravity on the seat adapter 1 Loosen all mounting screws countersunk head screws between the seat plate and seat plate supports see Fig 10 item 1 2 Loosen the
8. 2112 e mail ottobock ottobock co jp www ottobock co jp Otto Bock Korea HealthCare Inc 4F Agaworld Building 1857 74 Seocho dong Seocho ku 137 070 Seoul Korea Phone 82 2 577 3831 Fax 82 2 577 3828 e mail info ottobockkorea com www ottobockkorea com Otto Bock South East Asia Co Ltd 1741 Phaholyothin Road Kwaeng Chatuchark Khet Chatuchark Bangkok 10900 Thailand Phone 66 2 930 3030 Fax 66 2 930 3311 e mail obsea otttobock co th www ottobock co th Other countries Otto Bock HealthCare GmbH Max N der StraBe 15 37115 Duderstadt Germany Phone 49 5527 848 1590 Fax 49 5527 848 1676 e mail reha export ottobock de www ottobock com Ihr Fachh ndler Your specialist dealer Versandanschrift f r Rucksendungen Adress for Returns Otto Bock Manufacturing K nigsee GmbH LindenstraBe 13 07426 K nigsee Germany I Otto Bock Mobility Solutions GmbH LindenstraBe 13 07426 K nigsee Germany Phone 49 69 9999 9393 Fax 49 69 9999 9392 ccc ottobock com www ottobock com Otto Bock has a certified Quality Management System in accordance with ISO 13485
9. 6 lbs 17 kg 37 5 Ibs Between the lateral guides of the armrest lateral guides without optional seat plates Without footrests anti tipper with 12 wheels Without wheels footrests armrests and seating unit Wheel size in Tire pressure in bar 12 rear wheel 16 rear wheel 22 reor wheel 24 rear wheel For the allowable air pressure also see the markings on the tire INFORMATION Note the safety instructions regarding air pressure and tires see Page 8 f 22 01 2012 Kundenservice Customer Service Europe Otto Bock HealthCare Deutschland GmbH Max N der Str 15 37115 Duderstadt Germany Phone 49 5527 848 3433 Fax 49 5527 848 1460 e mail healthcare ottobock de www ottobock de Otto Bock Healthcare Products GmbH Kaiserstra e 39 1070 Wien Austria Phone 43 1 5269548 Fax 43 1 5267985 e mail vertrieb austria ottobock com www ottobock at Otto Bock Adria Sarajevo D O O Omladinskih radnih brigada 5 71000 Sarajevo Bosnia Herzegovina Phone 387 33 766200 Fax 387 33 766201 e mail obadria bih net ba www ottobockadria com ba Otto Bock Bulgaria Ltd 41 Tzar Boris Ill Blvd 1612 Sofia Bulgaria Phone 359 2 80 57 980 Fax 359 2 80 57 982 e mail info ottobock bg www ottobock bg Otto Bock Suisse AG Pilatusstrasse 2 CH 6036 Dierikon Phone 41 41 455 61 71 Fax 41 41 455 61 70 e mail suisse ottobock com www ottobock ch Otto Bock CR s r o Pr
10. C V Prolongaci n Calle 18 No 178 A Col San Pedro de los Pinos C P 01180 M xico D F Mexico Phone 52 55 5575 0290 Fax 52 55 5575 0234 e mail info ottobock com mx www ottobock com mx Otto Bock HealthCare Two Carlson Parkway North Suite 100 Minneapolis MN 55447 USA Phone 1 763 553 9464 Fax 1 763 519 6153 e mail usa customerservice ottobockus com www ottobockus com Asia Pacific Otto Bock Australia Pty Ltd Suite 1 01 Century Corporate Centre 62 Norwest Boulevarde Baulkham Hills NSW 2158 Australia Phone 61 2 8818 2800 Fax 61 2 8814 4500 e mail healthcare ottobock com au www ottobock com au Beijing Otto Bock Orthopaedic Industries Co Ltd B12E Universal Business Park 10 Jiuxiangiao Road Chao Yang District Beijing 100015 P R China Phone 8610 8598 6880 Fax 8610 8598 0040 e mail news service ottobock com cn www ottobock com cn Otto Bock Asia Pacific Ltd Suite 3218 32 F Sun Hung Kai Centre 30 Harbour Road Wanchai Hong Kong China Phone 852 2598 9772 Fax 852 2598 7886 e mail info ottobock com hk Otto Bock HealthCare India Behind FairLawn Housing Society St Gregorios Lane Sion Trombay Road Chembur Mumbai 400071 India Phone 91 22 2520 1268 Fax 91 22 2520 1267 e mail information indiaottobock com www ottobock in Otto Bock Japan K K Yokogawa Building 8F 4 4 44 Shibaura Minato ku Tokyo 108 0023 Japan Phone 81 3 3798 2111 Fax 81 3 3798
11. Wo Rock QUALITY FOR LIFE AS ta h Ge 8 N 1 AR Ed K N V IN im p gt v I t a t a DE 7 ines d r ku AG PAS me gt 900 q lt st IN gt ey N discoverytm ey A S N XA d 7 I 9 discovery tmax Instructions for Use Qualified Personnel Ottobock 647G734 EN 03 1201 Cito Bode 01 2012 Otto Pode Table of contents Table of contents 1 2 7 8 FOP SV o o e no HE A 5 PROD MCONI OM AA E o A 5 TC SO cia 5 22 INQICONONS RIETI EET EEE UE o oo 5 23 COMQUIOICONON UP Tr s 5 24 Reguired QUIMICO Siria 5 A TTE TT T c c 6 3 1 Explanation of Warning Symbols auaaaaaa na n na nnnnnnnnnnnnnnnnnnnnnnnnnnnnannnnnnnnnnnnnnnnannnnnnnnnnnannnnnnnnnnnannnnannnannanan nana 6 32 General Soley IASTTUCHIONS RTT UT mes 6 3 3 Safety instructions for assembly aaaanaannnnnnnn nnnnnnnnnnnnnnnnnnnnnnnnnnnnannnnnnnnnnnnnnnnnnnnnnnnnnnnannnnnnnnnnnannnnannnannnnnnnanan aa 7 44 Type dd 6 Ree er NEE E mo o A on 7 LONI o A T A 7 BT SCONE OF DENVER ii t 7 BD OPHORNS iria iii iio dd ad 8 1438 SOTO e 8 PrEDALAHON TOR LISO RERUM 8 5 1 10015 TOO CG nto tac 8 D ASSO c 8 AQIISINEONES ee ee OTT ETE 9 ME od E I E O PIE OOE A ION AE IEE NEA N E A E E E A A ee 9 611 Setlings during FOO SS CMD sia ee AEE ATA RRR 10 6 2 Adj
12. ded that it is used properly and that the service and maintenance instructions are observed Storage times at the dealer or with paying parties are not included in this period However we would like to emphasise that the product is reliable far beyond this defined period of time provided that it is cared for and maintained properly The product must first be thoroughly cleaned and disinfected before it can be re used Then the product must be examined by an authorised specialist to check the condition and to look for wear and possible damage All worn and damaged parts as well as components which do not fit or are unsuitable for the new user must be replaced Detailed information on replacing components as well as information on the required tools and the prescribed service intervals can be found in the service manual 10 Legal Information 10 1 Liability The manufacturer s warranty applies only if the device has been used under the conditions and for the purpose described The manufacturer recommends that the device be used and maintained according to the instructions for use The manufacturer is not responsible for damages caused by components and spare parts not approved by the manu facturer Repairs must be carried out exclusively by authorised dealers or by the manufacturer 10 2 CE Conformity This device meets the requirements of the 93 42 EEC guidelines for medical devices This device has been classi fied as a class device accordi
13. ion of the seating centre of gravity is required with the seated user and the designated attendant adjustments must be made if necessary The seating centre of gravity must be set so that the attendant can change the angle effortlessly 20 01 2012 f f CA Bocha Maintenance Repair e Attendants and if possible the user must be instructed in the safe use of the wheelchair In particular the enclosed Instructions for Use User are to be used for this purpose e The Instructions for Use User must be provided to the user attendant upon delivery of the wheelchair 8 Maintenance Repair We recommend regular maintenance of the product every 12 months More information on cleaning disinfection and maintenance repair is found in the instructions for use user Detailed information on repairs can be found in the service manual 9 Disposal 9 1 Disposal information In case of disposal all components of the product must be disposed of in accordance with the respective national environmental laws 9 2 Information on Re Use The product is suitable for re use Similar to second hand machines or vehicles products that are being re used are subject to increased strain Features and functions must not change in a way that could endanger patients or other persons within the product s lifespan Based on market observations and the current state of technology the manufacturer has calculated that the product can be used for a period of 5 years provi
14. n more detail in the included instructions for use user reference number 6476733 16 01 2012 f f CA Bocha Adjustments 6 11 Adjusting the Wheel Adapters A CAUTION Incorrectly adjusted wheelbase Risk of the user falling or tipping over Only adjust the wheel adapter after completing the adjustments described above Maximum stability is reached in the far rear position wheel adapter is up against the stop screw see Fig 20 item 2 When the wheel adapter is moved forward the stability of the wheelchair decreases Avoid extreme settings that could lead to tipping when adjusting the seat angle Adjust the wheelbase so that the person pushing the wheelchair has to exert little force to tip it Please note that with the rear wheel in the front position and with an unfavourable body position the user may tip backwards even on level ground Be sure to position the rear wheels towards the rear for transfemoral amputees This improves the stability of the wheelchair Changing the size and position of the rear wheels may cause the caster wheels to wobble at higher speeds If changes are required verify the horizontal alignment of the main frame INFORMATION gt To change the position of the wheel adapter the knee lever wheel lock first has to be loosened and subsequently readjusted see the chapter Adjusting the Knee Lever Wheel Lock gt The position of the wheel attachment bushings in the wheel adapter was matched to the chosen rea
15. n the front frame tube 3 Fold the footplates down If necessary insert the calf band and adjust it 4 Prior to the adaptation of the seating shell seating system further wheelchair settings must be adjusted as required see Page 9 et seq 6 Adjustments 6 1 Prerequisites Z WARNING Incorrect settings Risk of falling tipping over or improper user posture Adjustments may be carried out only by qualified personnel instructed by Otto Bock Only the settings described in these instructions for use may be carried out Settings may only be changed within the allowable adjustment ranges otherwise the stability of the product may be impaired see this chapter and the chapter Appendixes Please contact Otto Bock if you have any ques tions Only conduct tests in the presence of an assistant Unless expressly described you should not change any settings with a person sitting in the product Secure the user against falling out during all tests Activate the anti tipper during all tests Before testing setting changes with the user seated firmly tighten all screw connections Check for safe function before handing over the product Z WARNING vVVVVYV Failure to verify tipping resistance Risk of the user falling or tipping over gt Changing the settings can lead to instability of the system as a whole Verify tipping resistance after any changes to the settings A CAUTION Unsecured screw connections Risk of pinchi
16. nching crushing being pulled n gt Wear suitable work clothing and for example gloves and protective eyewear as necessary when working on the product A CAUTION Use of unsuitable tools Pinching crushing or damaging the product gt When working use only tools that are suitable for the conditions at the workplace and whose proper use ensures safety and health protection NOTICE Tipping or falling of the product Damage to the product gt When you work on the product secure it so that it cannot tip over or fall over gt Use a clamping device to secure the product for all work at a workbench NOTICE Wrong packaging Risk of damage to the product gt Use only the original packaging for delivery of the product 6 01 2012 Oto Pode Delivery 3 3 Safety instructions for assembly A CAUTION Unsecured screw connections Risk of pinching crushing tipping over falling of user gt After all adjusting readjusting work retighten the mounting screws nuts firmly Observe any torque settings which may be specified gt Any time you loosen a screw connection with thread lock replace it with a new screw connection or secure the old screw connection with medium strength thread locker e g Loctite 241 A CAUTION Improper use of self locking nuts Risk of the user falling or tipping over gt Always replace self locking nuts with new self locking nuts after disassembly A CAUTION Improper assembly of the remo
17. ng crushing tipping over falling of user gt After all adjusting readjusting work retighten the mounting screws nuts firmly Observe any torque settings which may be specified gt Any time you loosen a screw connection with thread lock replace it with a new screw connection or secure the old screw connection with medium strength thread locker e g Loctite 241 A CAUTION Improper use of self locking nuts Risk of the user falling or tipping over gt Always replace self locking nuts with new self locking nuts after disassembly Fine adjustments and setting changes to match the concrete physical and mental condition of the user should always be made in the user s presence All parts of the product should be cleaned thoroughly before adjustments are made 01 2012 9 Adjustments Otto Bocha 6 1 1 Settings during Preassembly If the seating shell seating system as well as the back system have already been preassembled the following chapters can be omitted e Chapter Adjusting the Seat Width see Page 10 e Chapter Adjusting the Seat Depth see Page 11 e Chapter Adjusting the Back Angle see Page 11 e Chapter Adaptation of the Seating Shell Seating System see Page 12 6 2 Adjusting the Seat Width 6 2 1 Adjusting the Width of the Main Frame Within the allowable adjustment range the width of the main frame can be adapted to the width of the chosen seating shell or seating system 1 Remove the seat frame fr
18. ng force Adjustment by sliding in the slotted hole fine tuning if needed 1 Loosen 2 x Allen head screws on the slotted hole of the clamping plate see Fig 21 see Fig 23 item 3 2 The knee lever wheel lock is continuously adjustable in the slotted hole see Fig 21 see Fig 23 item 4 When the wheel lock is disengaged the gap between the tyre and wheel lock bolt must not exceed approx 5 mm see Fig 22 see Fig 24 3 Tighten all Allen head screws to a torque of 10 Nm INFORMATION After adjustment the left and right knee lever wheel lock must have the same braking force 18 01 2012 Adjustments 6 13 Adjusting the Tip Assist The depth of the tip assist can be changed It must be adjusted after changing the seating centre of gravity 1 Loosen the Allen head screw see Fig 25 2 Slide the tip assist in the main frame as required 3 Tighten the Allen head screw to a torque of 10 Nm 6 14 Adjusting the Anti Tipper A CAUTION Incorrect fitting of anti tipper missing anti tipper Risk of tipping of the user to the rear gt Check correct installation and adjustment of the anti tipper gt Depending on the adjustment of the chassis the wheelchair centre of gravity and the experience of the user an anti tipper may be necessary A CAUTION Incorrect anti tipper setting Risk of tipping over falling loss of functionality gt After it is adjusted the anti tipper always has to protrude a few centimetre
19. ng systems that have not been approved by Otto Bock see Page 21 2 Application 2 1 Intended Use The wheelchair is intended exclusively for the adaptation of seating shells and other orthopaedic seating systems for people who are unable to walk or have walking impediments It can be operated either by the user or by an attendant The product can be used indoors and outdoors In order to provide an optimised individual fitting it is adjustable and or adaptable The product may only be used with the options which are listed in the product order form The Otto Bock warranty applies only when the product is used according to the specified conditions and for the inten ded purposes 2 2 Indications This wheelchair is suitable for fittings for users in all age groups The use of various orthopaedic seating systems e g seating shells and the variety of adjustment possibilities make the wheelchair suitable for use in case of inability to walk walking impediments e g due to e Paralysis paraplegia tetraplegia Loss of limbs leg amputation Limb defect deformity Joint contractures defects Neurological and muscular diseases 2 3 Contraindications None 2 4 Required Qualifications The adjustment tasks described below are necessary for optimum adaptation to the respective seating system and may only be completed by qualified authorised personnel orthopaedic authorised personnel specialist dealers for rehabilitation products 01
20. ng to the classification criteria outlined in appendix IX of the guidelines The declaration of conformity was therefore created by Otto Bock with sole responsibility according to appendix VII of the guidelines 10 3 Warranty Terms and Conditions Further information on the warranty terms and conditions is available from Otto Bock Service see inside back cover for addresses 11 Appendices 11 1 Technical Data Children Adults EE E Sizei Size2 Sie3 Sie4 14 18 16 20 18 22 20 24 35 45 cm 40 50 cm 45 55 cm 50 60 cm Seat width between armrests 12 16 14 18 16 20 18 22 30 40 cm 35 45 cm 40 50 cm 45 55 cm 01 2012 21 Appendices to Rock Seat width outside edge seat tubes 11 15 13 17 15 19 17 21 28 38 cm 33 43 cm 38 48 cm 43 53 cm Seat depth 12 16 15 19 15 22 15 22 30 40 cm 37 5 47 5 cm 37 5 55 cm 37 5 55 cm Rear wheels 12 16 22 24 6 7 8 Turning radius base frame 1050 Max allowable incline 10 Seat tube height 14 18 16 20 16 20 16 20 35 45 cm 40 50 cm 40 50 cm 40 50 cm 5 50 Backrest height 21 24 from seat plate 53 cm 61 cm from seat plate Backrest angle 5 430 Overall length from 21 from 27 from 53 cm from 61cm from 61 cm from 68 5 cm Total load capacity 136 kg 300 Ibs Angle adjustable push bar height 7 18cm Frame weight 15kg 33 lbs 16 kg 35lbs 16 5kg 3
21. nnnn nnnnnnnnnnnnnnnnannnnnnnnnnnannnnnnnnnnnnnnnnannnnana 15 6 10 Adjusting the Side Panels aa2nanna nn nnnn nannnnnnnnnannnnnnnnnnnnnnnnannnnnnnnnnnannnnnnnnnnnnnnnnannnnnnnnannannnnannnnnnnnnnnan annan 16 6 10 rae Piero Me eec Ro MEN P 16 6 102 JAQIHSUDO Me Anrnrest HEIJN O surdi Suh iru rnini esac aio 16 6 11 Adjusting the Wheel Adapters aaaaaaana nnn nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnan 17 6 12 Adjusting the Knee Lever Wheel Lock aaaanananaa nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 18 6 13 Adjusting the Tip ASSIS ERROR dot 19 6 14 Adjusting the ANA een ernennen een Eee 19 POST caiara cece In O 20 7 3 FUG SSC CU OIA isidro 20 7 2 Transport TO Me CUSTOMER dos 20 ho A ate 20 Maintenance Repadir aaaa2aaaaa2aaaaaaaxaaannnnunnnnnnnnnnnunnnnunnnnnnunnnnunnnnnnnnnnnunnnnunnnnnnnnnnnnnnnnnnnnnnnnnnununnnnnnnnnNnNNNNNNNNNNNNNNNANNNNR 21 01 2012 3 9 MUS OS Mee ME 21 91 DISPOSICION ias 21 92 Information on RS USO ni ici 21 TO LEGON INFORMAUON NE 21 ARA AAA nn E a Ee CAS a ene eee 21 102 CE Con On AAN aco ya O R R NATER ANSETE STE ARANE 21 10 3 Warranty Terms and Conditions aaaaxaaan nn n nnnnnnnnnnnannnnnnnnnnnannnnnnnnnnnnnnnnnnnnnnnnnnannnnnnnnnnnnnnnnnnnnnnnnnnnnannnn an 21
22. ntral seat fork see Fig 3 ttem 3 Loosen 2 x Allen head screws with counter nuts on the locking bar see Fig 3 ttem 4 6 With push bar option loosen 2 x Allen head screws on the connecting tube see Fig 4 item 5 Adjust the width on all connecting tubes preferably making it symmetrical INFORMATION If required an asymmetry of 12 5 mm 1 2 is allowable when adapting the connecting tubes The asymmetry must be on the same side on all connecting tubes However the allowable adjustment range must not be exceeded When using a seat plate reinstall the seat plate see Page 12 8 Tighten all Allen head screws to the following torque values Item 1 2 38 10 Nm 10 01 2012 f f Bocha Adjustments Item 4 Allen head screws 8 Nm counter nut 10 Nm Item 5 8 Nm gt Mount the seat frame on the main frame see Page 13 6 3 Adjusting the Seat Depth The seat depth can be changed by vertically adjusting the back tubes on the seat frame 1 When using a seat plate remove the seat plate see Page 12 2 Loosen 2 x Allen head screws on the back plate seat frame connection on both sides see Fig 5 item 1 and remove the rear connecting tube see Fig 6 item 1 3 Ifa lashing point is installed also loosen the 1 x Allen head screw 1 x pin see Fig 5 item 2 3 4 Adjust the seat depth slide the back plates to the desired depth position see Fig 6 item 2 INFORMATION Ensure that the angle positi
23. om the main frame see Page 13 2 Loosen 4 x Allen head screws on each of the adjustment tubes at the rear see Fig 1 item 1 and front see Fig 2 item 2 3 Adapt the width on the adjustment tubes preferably making it symmetrical INFORMATION The connection between the adjustment tube and frame always has to be realised on both sides with 2 Allen head screws use inner 2 bores INFORMATION If required an asymmetry of 12 5 mm 1 2 is allowable when adapting the adjustment tubes The asymmetry must be on the same side on all adjustment tubes However the allowable adjust ment range must not be exceeded Firmly retighten all Allen head screws to a torque of 10 Nm 4 Mount the seat frame on the main frame see Page 13 6 2 2 Adjusting the Width of the Seat Frame INFORMATION gt Before adjusting the seat frame the main frame needs to be adjusted see the preceding chapter gt Incase of a seating shell seating system preinstalled at the factory these settings do not have to be changed The width of the seat frame can be adapted to the width of the chosen seating shell or seating system 1 When using a seat plate remove the seat plate see Page 12 2 Remove the seat frame from the main frame see Page 13 3 Loosen 4 x Allen head screws on each of the connecting tubes at the front see Fig 3 item 1 and rear see Fig 3 item 2 Loosen 2 x Allen head screws with counter nuts on the connecting tube of the ce
24. on is not changed use the same bore After adjusting the back plate reinstall the rear connecting tube 5 When using a seat plate reinstall the seat plate see Page 12 6 Tighten all Allen head screws to 10 Nm 6 4 Adjusting the Back Angle A CAUTION Unallowable back angle Risk of the user falling or tipping over gt A back angle setting greater than 30 is not permitted INFORMATION gt Ensure the angle setting is symmetrical on both sides of the back frame gt Note that the seating position may have to be readjusted for an optimum seating centre of gravity The back angle can be adjusted from 5 to 30 off the vertical position 01 2012 11 Adjustments Otto Bocha a Angle adjustment in 10 increments 1 Loosen the upper Allen head screw on the back plate see Fig 8 item 1 2 Loosen and remove the angle adjustment screw on the back plate see Fig 8 item 2 3 Adjust the backrest to the desired angle with the help of the existing bores 4 Tighten all Allen head screws to 10 Nm 5 Proceed the same way on the other side b Setting 5 interim angles 1 Loosen the front Allen head screw see Fig 9 item 1 2 Loosen and remove the rear Allen head screw see Fig 9 item 2 3 With installed lashing point loosen 1 x Allen head screw 1 x anchor point see Fig 9 item 3 4 Adjust the backrest angle by 5 Use the available bore for this purpose 5 Tighten all Allen head screws to 1
25. oning In order to do so measure the distance from the end of the frame tube to the back edge of the adapter see Fig 19 item 2 The maximum allowable deviation is 1 mm 7 Firmly retighten all Allen head screws to a torque of 10 Nm 8 Mount the locking mechanism linkage see Page 14 9 Readjust the knee lever wheel lock see Page 18 01 2012 17 Adjustments 6 12 Adjusting the Knee Lever Wheel Lock A CAUTION Insufficient braking action of the knee lever wheel lock Risk of accidents falling gt Maintain sufficient air pressure in pneumatic tires For the correct air pressure see the chapter Technical Data When the rear wheel position is changed adjusting the wheel adapter or in case of readjustment the knee lever wheel lock must be adjusted on both sides After changing the position of the rear wheel Otto Bock recommends adjusting the knee lever wheel lock by shifting it on the frame Adjustment by shifting on the frame standard setting 1 Loosen 2 x Allen head screws on the clamping plate of the knee lever wheel lock see Fig 21 see Fig 23 item 1 2 Slide adjust the clamping plate on the frame see Fig 21 see Fig 23 item 2 When the wheel lock is not engaged the gap between the tire and the wheel lock bolt should be 5 mm max see Fig 22 see Fig 24 3 Tighten all Allen head screws to a torque of 10 Nm INFORMATION After adjustment the left and right knee lever wheel lock must have the same braki
26. oper assembly of the removable wheels Risk of the user falling or tipping over gt After each assembly verify the proper fit of the removable wheels The quick release axles must be firmly locked in the wheel attachment A CAUTION Incorrect air pressure Risk of falling uncontrolled driving characteristics tire rupture gt Maintain sufficient air pressure Do not exceed the maximum specifications when filling the tires see the chapter Technical Data gt Do not use the wheelchair with over under inflated or unequally inflated tires gt Note that a single tire with low air pressure can lead to uncontrolled driving characteristics gt Note that low rear tire pressure can reduce the braking force of the knee lever wheel lock 8 01 2012 Otto Pode Adjustments INFORMATION In general only metric screws are used on the product Exception axle mounting of the 12 rear wheels 1 2 hexagon head screw hexagon nut INFORMATION With the combination of Allen head screw hexagon nut a higher torque can be transmitted using the hexagon nut than the Allen head screw Please note that the Allen head screw is only intended to be held in place so it does not turn when tightening loosen ing the hexagon nut 1 For plug on rear wheels slide the rear wheels onto the wheel attachments of the wheel adapters The quick release axles must not be removable after releasing the pushbutton 2 Slide the footrests into the holders o
27. ored in a dry place For transportation and storage an ambient temperature between 10 C and 40 C must be maintained During extended storage the knee lever wheel lock on wheelchairs with PU tyres must be released since tyre deforma tion may otherwise result Note regarding the tires e Tires contain chemical substances that can react with other chemical substances such as cleaning agents acids etc e Direct exposure to sunlight UV radiation causes the tires to age more quickly As a result the tread surface hardens and corner pieces break out of the tread e Avoid unnecessary parking outdoors The tires should be replaced every 2 years regardless of wear and tear 5 Preparation for Use 5 1 Tools required The following tools are required to make fine adjustments setting changes e Allen key size 3 4 5 mm Ring open end wrench size 10 19 24 Socket wrench size 10 19 Phillips screwdriver size 2 Flat screwdriver size 3 Torque wrench measurement range 5 50 Nm 5 2 Assembly A CAUTION Loss of stability due to additional objects on the product Tipping falling from the seating shell seating system breakage of load bearing components gt Do not attach additional objects to the frame cross tubes or seat A CAUTION Breakage of load bearing components due to overloading Falling tipping injuries due to frame breakage gt Do not exceed the maximum load capacity see chapter Technical Data A CAUTION Impr
28. ortugal Phone 351 21 3535587 Fax 351 21 3535590 e mail ottobockportugal mail telepac pt Otto Bock Polska Sp z o o Ulica Koralowa 3 61 029 Poznan Poland Phone 48 61 6538250 Fax 48 61 6538031 e mail ottobock gottobock pl www ottobock pl Otto Bock Romania srl Sos de Centura Chitila Mogosoia Nr 3 077405 Chitila Jud Ilfov Romania Phone 40 21 4363110 Fax 40 21 4363023 e mail info ottobock ro www ottobock ro OOO Otto Bock Service p o Pultikovo Business Park Greenwood Building 7 69 km MKAD 143441 Moscow Region Krasnogorskiy Rayon Russian Federation Phone 7 495 564 8360 Fax 7 495 564 8363 e mail info ottobock ru www ottobock ru Otto Bock Scandinavia AB Koppargatan 3 Box 623 60114 Norrk ping Sweden Phone 46 11 280600 Fax 46 11 312005 e mail info ottobock se www ottobock se Otto Bock Slovakia s r o R ntgenova 26 851 01 Bratislava 5 Slovak Republic Phone 421 2 32 78 20 70 Fax 421 2 32 78 20 89 e mail info ottobock sk www ottobock sk Otto Bock Sava d o o Maksima Gorkog bb 18000 Nis Republika Srbija Phone 381 18 4285888 Fax 381 18 4539191 e mail info ottobock rs www ottobock rs Otto Bock Ortopedi ve Rehabilitasyon Teknigi Ltd Sti Ali Dursun Bey Caddesi Lati Lokum Sokak Merig Sitesi B Block No 6 1 34387 Mecidiyek y Istanbul Turkey Phone 90 212 3565040 Fax 90 212 3566688 e mail info ottobock com tr www ottobock com tr Africa
29. otetick 460 33008 Zru Senec Czech Republic Phone 420 377825044 Fax 420 377825036 e mail email ottobock cz www ottobock cz Otto Bock Iberica S A C Majada 1 28760 Tres Cantos Madrid Spain Phone 34 91 8063000 Fax 34 91 8060415 e mail info ottobock es www ottobock es Otto Bock France SNC 4 rue de la R union CS 90011 91978 Courtaboeuf Cedex France Phone 33 1 69188830 Fax 33 1 69071802 e mail information ottobock fr www ottobock fr Otto Bock Healthcare plc 32 Parsonage Road Englefield Green Egham Surrey TW20 OLD United Kingdom Phone 44 1784 744900 Fax 44 1784 744901 e mail bockuk ottobock com www ottobock co uk Otto Bock Hungaria Kft Tatai t 74 1135 Budapest Hungary Phone 36 1 4511020 Fax 36 1 4511021 e mail info ottobock hu www ottobock hu Otto Bock Adria d o o Dr Franje Tu mana 14 10431 Sveta Nedelja Croatia Phone 385 1 3361 544 Fax 385 1 3365 986 e mail ottobockadria ottobock hr www ottobock hr Otto Bock Italia Srl Us Via Filippo Turati 5 7 40054 Budrio BO Italy Phone 39 051 692 4711 Fax 39 051 692 4720 e mail info italia ottobock com www ottobock it Otto Bock Benelux B V Ekkersrijt 1412 5692 AK Son en Breugel The Netherlands Phone 31 499 474585 Fax 31 499 476250 e mail info benelux ottobock com www ottobock nl Industria Ortop dica Otto Bock Unip Lda Av Miguel Bombarda 21 2 Esq 1050 161 Lisboa P
30. plate settings the footplate can collide with the caster wheels The footplates are the supporting surfaces for the feet Their distance from the seat bottom influences sitting stability The height adjustment acts on the pelvis and ischial bones The angle of the footplate should permit a comfortable ankle position 6 8 1 Adjusting the Depth of the Footrest Adapter The depth of the various footrests can be adjusted by moving the footrest adapters in the hole channel of the seat frame members 1 Loosen the Allen head screws on the seat frame see Fig 15 item 1 2 Remove the lashing point if applicable 3 Slide the footrest adapters to the desired position see Fig 15 item 2 INFORMATION Note the minimum insertion depth The footrest adapters need to be secured with 2 screws 4 Firmly retighten all Allen head screws to a torque of 10 Nm 6 8 2 Other Settings The following adjustments are described in more detail in the included instructions for use user for all footrests that are offered reference number 6476733 e Adjusting the lower leg length e Adjusting the footplate angle 6 9 Checking Adjusting the Seating Centre of Gravity A CAUTION Improper adjustment of the seating centre of gravity Risk of tipping over falling from the seating shell seating system Avoid extreme settings that could lead to tipping when adjusting the seat angle Always choose centre of gravity settings so that the holding forces are as low as
31. r wheel size caster wheel size at the factory The wheel adapter can be shifted on the main frame This has the following effects Wheel adapter rear wheel position Effects Shifting to the rear farther away from the Larger wheelbase tipping resistance increases seating centre of gravity wheelchair is harder to tip backwards when crossing obstacles larger forces required for tipping Shifting forward closer to the seating Smaller wheelbase tipping resistance is reduced centre of gravity wheelchair is easier to tip backwards when crossing obstacles lower forces required for tipping Setting recommendations Depending on the clinical picture of the user the intended area of application and the experience strength of the attendant the position of the wheel adapter can be individually readjusted The adjustments should be made as fol lows e Little force needs to be exerted when tipping up the wheelcharr e The wheelchair will stand stable at all times on slopes inclines Adjusting the wheel adapter Loosen the locking mechanism linkage see Page 14 If necessary loosen the knee lever wheel and remove the rear wheels Loosen 3 x Allen head screws on the wheel adapter on both sides see Fig 19 see Fig 20 item 1 N C2 o gt St Oe 4 Adjust the depth of the wheel adapter on both sides at the same time Avoid tilting or canting 5 Slightly tighten all Allen head screws 6 Verify even positi
32. s beyond the outer radius of the rear wheel Length and height adjustments must always be done the same way on both sides After making adjustments take note of the sound made by the tripod spring as it engages After making any adjustments to the product verify the proper functionality of the anti tipper Adjust the anti tipper if needed If the anti tipper settings need to be adjusted e g when changing the seat height wheel size or position of the wheel adapter the anti tipper can be adjusted in both length and height 01 2012 19 Handover Otto Boda a Adjusting the length The length adjustment of the anti tipper must not be realised via the ratchet mechanism but only by changing the posi tion of the cross tube 1 Press in the tripod spring and remove the anti tipper from the cross tube see Fig 26 item 1 2 Loosen remove the Allen head screws on the cross tube see Fig 26 item 2 3 Adjust the depth of the cross tube Use the existing bores in the cross tube for this purpose 4 Tighten the Allen head screw on the cross tube to a torque of 8 Nm 5 Push in the tripod spring and slide the anti tipper into the cross tube INFORMATION After making this adjustment the anti tipper has to protrude a few centimetres beyond the outer radius of the rear wheel The anti tipper must be fully inserted into the cross tube 6 Visually check that the anti tipper has engaged b Adjusting the height 1 Push in the tripod
33. s process 3 Select the new seat height Move the seat up or down in the adapter tube in order to do so INFORMATION Note the allowable seat height settings see the chapter Technical Data Please note that excessive seat height can lead to overall system instability with large heavy seating shells 4 Firmly retighten all Allen head screws to a torque of 10 Nm 5 Adjust install the locking mechanism linkage see Page 14 01 2012 13 Adjustments o Bocha 6 7 Adjusting the Locking Pedal A CAUTION Incorrect setting of the locking mechanism linkage Falling from the seating shell malfunction damage to destruction of the release mechanism gt Adjust the length of the locking mechanism linkage so that the locking pins fully engage in the locking plate in the seat frame and the locking mechanism is in the front position Only then is the support of the seat assured with extreme settings or when driving over rough surfaces gt Secure the screw connections of the locking mechanism linkage so it is free of tension without pulling or pushing Changing the seat height see Page 13 or the positions of the wheel adapters see Page 17 requires changing the length of the locking mechanism linkage 1 Loosen 2 x Allen head screws on the locking mechanism linkage see Fig 13 item 1 2 Change the seat height or the position of the wheel adapters 3 Prior to assembly determine the correct length of the locking mechanism linkage
34. spring see Fig 27 item 1 2 Adjust the height of the anti tipper in the anti tipper adapter see Fig 27 item 2 INFORMATION The anti tippers must be no more than 5 cm above the floor 3 Visually check that the anti tipper has engaged 7 Handover 7 1 Final Inspection A final inspection is required before the product is delivered e Are all options installed according to the order form Do the wheels turn easily Is the seating shell seating system correctly adapted to the user Is the seating centre of gravity adjusted correctly Are the footplates side panels adjusted correctly Is the wheel adapter mounted with the specified torque Can the quick release axles be easily removed For pneumatic tires is the tire pressure correct see the section Technical Data Have the wheel locks been adjusted correctly Is the anti tipper mounted and adjusted correctly Have all screws been properly tightened 7 2 Transport to the customer The wheelchair should be transported to the user in disassembled state using the outer packaging 7 3 Delivery The following steps should be performed for the safe delivery of the wheelchair e Seating trials were conducted with the user while adjusting the settings Proper positioning according to medical aspects must once again be verified upon delivery seating position position of the arm rests footrests e n order to ensure that the seat tilt feature operates smoothly final verificat
35. ters see Page 12 3 Slide the seat to the assumed seating centre of gravity on both sides 4 Tighten all clamping screws to a torque of 10 Nm 5 Conduct a functional test of the locking mechanism Tilt the seat e g to 25 and lock tt Ensure that the tipping movement and locking function operate easily 6 Test the seating centre of gravity setting Sit the user in the seat with the help of an assistant Tilt the seat and hold it in position Only low holding forces should be required for tilting Adjusting the seating centre of gravity If the results are not satisfactory the setting has to be readjusted without the user in the seat as follows Problem NS Seat tilts far forward when it is unlocked Open the seat clamp and slide the seat back large holding forces required during seat adjustment Seat tilts far backward when it is unlocked Open the seat clamp and slide the seat forward large holding forces required during seat adjustment y e 6 10 Adjusting the Side Panels 6 10 1 Adjusting the Armrest Depth The armrest position can be adjusted to the forearm length 1 Loosen 2 x Allen head screws on the bottom of the armrest see Fig 16 item 1 2 Slide the armrest forward or backward along the connection tube to the desired position 3 Insert 2 x Allen head screws into the originally used bore holes and tighten to 8 Nm 6 10 2 Adjusting the Armrest Height Adjusting the armrest height is described i
36. usting the Seat MIO ici A A nan anna 10 627 Adjusing ne Widinorine Man Fram posesiones k asa 10 6 2 2 Adjusting the Width of the Seat Frame m 10 03 AGIUSTING he Seo DON 11 6 4 Adjusting the Back Angle accord 11 6 5 Adaptation of the Seating Shell Seating System aaxzaananaaan nnnnnnnnnnnnnnnnnnnnnnnnnnannnnnnnnnnnnnnnnannnnnnnnnnnannnnann 12 6 5 1 Installing a Seating Shell Otto Bock Shape System Option iannnnv sssvnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnna 12 6 5 2 Removing Installing a Seat Plate Option esses seien nnne nnn nnn 12 6 5 8 Installing Otto Bock Back Systems Option nnnnnvnannnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnannnnnna 13 6 5 4 Installing other Seating Systems Back Systems isse eene nnne 13 6 6 Adjusiing the Seat Height ouis cuba dua ree a EV Su PESE eee Sa 13 6 7 Adjusting the LOCKING Pedal aaaaaanannnnnnnnnnnnnnnnnnnunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 14 6 8 Adjusting the Footrests Footplates aaaanaanna n nn n nnnnnnnnnnnnnnannnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnannnnannnnnnnnnnnan nan anna 15 6 8 1 Adjusting the Depth of the Footrest Adapter asaaaanaasns nnnannnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnannnannnnnnnnnnannnanna 15 E ONT SCUND arra sta a E TAPEET AIR N TA T NEREA TTEA 15 6 9 Checking Adjusting the Seating Centre of Gravity aaaaanaaan nnnn
37. vable wheels Risk of the user falling or tipping over gt After each assembly verify the proper fit of the removable wheels The quick release axles must be firmly locked in the wheel attachment 3 4 Type Plate ke Meaning Maximum load capacity see the chapter Technical Data CE marking product safety according to EU guidelines The type label is located on the front connect ing tube of the base frame Seat angle setting indicator Only in case of anchor point system installation Mounting point anchor point system for attaching the product in a wheelchair accessible vehicle LIPPE 4 Delivery 4 1 Scope of Delivery The product is delivered pre assembled with the rear wheels removed in case of the plug on version and packed in a crate The scope of delivery includes e Pre assembled wheelchair 2 rear wheels screwed or plug on Footrests Options as ordered Instructions for Use Authorised Personnel Instructions for Use User 01 2012 7 Preparation for Use Oto Bocha INFORMATION Only provide the Instructions for Use User to the user Seating shells seat cushions are not included in the scope of delivery and must be ordered separately 4 2 Options The functionality and operation of the options are described in more detail in the instructions for use user All of the available options accessories are listed on the order form 4 3 Storage The wheelchair must be st
Download Pdf Manuals
Related Search
Related Contents
Mode d`emploi des services MoCCAM en ligne Raccolta azioni tipo per la riduzioni delle emissioni climalteranti Sonos PLAY5BLACK User's Manual HÄNGEGLEITER HAND BUCH Combat-L 13-14 Datenbanken HOBO Pro v2 User's Guide StarTech.com 1U 17" HD 1080p Dual Rail Rackmount LCD Console w/ Fingerprint Reader and Front USB Hub Copyright © All rights reserved.
Failed to retrieve file