1. ELECTRICAL FLOOR PLAN SCALE 1 8 1 0 Corporate Office 1800 Route 34 Suite 101 ELECTRICAL FLOOR PLAN Wall NJ 07719 732 312 9800 HOUSING AUTHORITY CITY OF PERTH AMBOY Regional Offices FRENCGH amp PARRELLO Hackettstown NJ STANDYBY GENERATOR INSTALLATION New York NY 881 AMBOY AVENUE PERTH AMBOY NJ 08862 PERTH AMBOY No Revision Revised By Checked By MONMOUTH COUNTY NEW JERSEY DATE DESIGNED BY SCALE PROJECT NUMBER AMIN H GOMAA PE DRAWN BY CHECKED BY FIELD BOOK SHEET PROFESSIONAL ENGINEER NJ LIC No 24GE04842100 AMP AHG O u COPYRIGHT 013 FRENCH amp PARRELLO ASSOCIATES PA THE COPYING OR REUSE OF THIS DOCUMENT OR PORTIONS THEREOF WITHOUT THE WRITTEN PERMISSION OF FRENCH amp PARRELLO ASSOCIATES PA IS PROHIBITED DUE TO INHERENT ERRORS IN REPRODUCTION METHODS ERRORS MAY OCCUR WHEN SCALING THIS DRAWING JOB NAME PERTH AMBOY GENERATOR RATING 208 120V 4W 3PH 400A CIRCUIT DESCRIPTION JOB NO 6805 001 LOCATION EXTERIOR OF BUILDING CIRCUIT DESCRIPTION EXISTING MDP EXISTING POLE LOAD BRANCH A CIRCUIT BRANCH CIRCUIT SPACE EXISTING EXISTING LOAD EXISTING EXISTING LOAD EXISTING EXISTING EXISTING LOAD HIGHEST PEAK DEMAND KW PER PSE amp G FROM JULY 2013 PANEL TYPE NEMA 3R MOUNTING SURFACE MAIN CIRCUIT BREAKER
2. _ _jJ ELECTRICAL FLOOR PLAN 2 SPECIFICATIONS MAY REQUIRE WORK EQUIPMENT SYSTEMS METHODS ETC METAL RACEWAY WITH APPROVED FITTINGS UNLESS OTHERWISE INDICATED THAT IS NOT INDICATED ON THE DRAWINGS PANEL SCHEDULES 31 FEEDERS AND BRANCH CIRCUITS UNDERGROUND IN RACEWAY TYPE EXISTING EXTERIOR 7 N 400 AMP C T AND METER 3 DRAWINGS AND SPECIFICATIONS ARE INTENDED TO BE COMPLEMENTARY TO THHN THWN 90 DEGREE C SPECIFICATIONS EACH OTHER WHERE DISCREPANCIES OR CONFLICTS OCCUR THE sess s S CONTRACTOR SHALL INCLUDE THE MORE COSTLY METHOD INHISPROPOSAL 32 INTERIOR FEEDERS AND BRANCH CIRCUITS IN RACEWAY TYPE THHN 90 r SPE PICS DNINUED UNLESS CLARIFIED BY BULLETIN OR ADDENDUM ACKNOWLEDGED PRIOR TO DEGREE C nn m RECEIPT OF BIDS 33 FEEDERS SHALL BE MINIMUM 8 AWG BRANCH CIRCUIT WIRING MINIMUM 12 4 DRAWINGS SHALL NOT BE SCALED DRAWINGS ARE ESSENTIALLY AWG CONTROL WIRING MINIMUM 14 AWG UNLESS OTHERWISE INDICATED T L_ _ 1 DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS FEEDER AND BRANCH CIRCUITWIRINGLARGERTHAN IO0AWGSHALLBE eel Jl l x aeln n 3 J l l C C C PCC AND REQUIREMENTS OF THE WORK ALTHOUGH SIZE AND LOCATION OF STRANDED CONDUCTOR 10 AWG AND SMALLER STRANDED CONDUCTOR OR EQUIPMENT IS DRAWN TO SCALE WHEREVER POSSIBLE CONTRACTOR SHALL SOLID CONDUCT
3. EXISTING PANEL L 4 CONDENSING UNIT ACC 4 EXISTING KR A LIGHTING 1 20 EXISTING 0 0 LIGHTING 1 20 EXISTING 20 EXISTING EXISTING C BRANCH BKR CIRCUIT LOAD KVA POLE DOWNLIGHTING 38 JOB NO 6805 001 LOCATION STORAGE CLOSET CIRCUIT DESCRIPTION LIGHTING EXISTING EXISTING EXISTING KEF 1 FURNACE AH 4 RECEPTACLES 20 EXISTING EXISTING OUTDOOR LIGHTING RECEPTACLES 20 EXISTING EXISTING LIGHTING CONTACTOR COMPUTER RECEPTACLES 20 EXISTING EXISTING OFFICE REECPTACLES COMPUTER RECEPTACLES 20 EXISTING EXISTING EXIT LIGHTING WATER COOLER 20 EXISTING EXISTING RECEPTACLES COMPUTER RECEPTACLES 20 EXISTING EXISTING COPIER COMPUTER RECEPTACLES 20 EXISTING OFFICE LTG AND RECEPTACLES 20 EXISTING COMPUTER RECEPTACLES 20 EXISTING EXISTING ACC UNIT EXISTING LOAD COMPUTER RECEPTACLES EXISTING EXISTING EXISTING RECEPTACLES RECEPTACLES EXISTING EXISTING EXISTING AHU UNIT RECEPTACLES RECEPTACLES EXISTING LOAD SPACE EXISTING EXISTING EXISTING RECEPTACLES EXISTING EXISTING RECEPTACLES LIGHTING SPACE PANEL TYPE NEMA 1 MOUNTING SURFACE MAIN CIRCUIT BREAKER 150A lyPERPORJINS AAAS J QKA SYM FED FROM MDP NOTES TOTAL PHASE EXISTING
4. MOTOR APPLICATION WHERE SUCH LISTING IS APPLICABLE 40 DEMONSTRATE PRODUCT CAPABILITY AND COMPLIANCE WITH ZY Ia DISCONNECT SWITCH X INDICATES SWITCH SIZE Y INDICATES 12 ALL EQUIPMENT SHALL BE AS INDICATED OR AS APPROVED BY THE ENGINEER REQUIREMENTS OF ALL ELECTRICAL DEVICES EQUIPMENT AND SYSTEMS I NUMBER OF POLES Z INDICATES FUSE SIZE NF NON FUSED 13 SUBMIT SHOP DRAWINGS PRODUCT DATA SHEETS AND WIRING DIAGRAMS 41 PERFORM MANUFACTURER S RECOMMENDED TESTS AND SUBMIT RESULTS r L r a _ _ FOR ALL ELECTRICAL CONSTRUCTION MATERIALS DEVICES EQUIPMENT EXISTING L j EXISTING EXISTING EXISTING COMBINATION MAGNETIC MOTOR STARTER AND DISCONNECT APPLIANCES AND SYSTEMS 42 VERIFY PROPER ROTATION OF ALL ROTATING ELECTRICAL MACHINERY PANE sQ aq j 2 S Gl SC INDICA IES SWIIDHS T y iNDIDA TES NUMBER B 14 SUBMIT IN QUANTITY TO ALLOW DISTRIBUTION TO OWNER 2 ENGINEER 2 43 TEST GENERATORS AND TRANSFER SWITCHES IN ACCORDANCE WITH sl b 48 P9 o ID T TUE ENE NOsrUS D PRIME CONTRACTORS 1 EACH AND CONTRACTOR S OWN USE AS REQUIRED APPLICABLE SECTIONS OF INTERNATIONAL ELECTRICAL TESTING ASSOCIATION ACCEPTANCE TESTING SPECIFICATIONS FOR ELECTRIC POWER 1 15 UNLESS SPECIFICALLY INDICATED OR REQUESTED OTHERWISE BIND ALL DISTRIBUTION EQUIPMENT AND SYSTEMS NETA ATS 1999 PERFORM EACH PRODUCT DATA TOGETHER PROPERLY INDEXED AND IDENTIFIED AND WITH VISUAL AND MECHA
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g Om k IBC BUILDING CODE 2 IBC BASIC MECHANICAL CODE SOUND ENCLOSURE FEATURES A INCLUDES ALL OF THE WEATHER ENCLOSURE FEATURES WITH THE ADDITION O
6. ALL OUTLET BOXES FOR INTERIOR USE SHALL BE GALVANIZED STAMPED STEEL 4 SQUARE FURNISHED WITH KNOCKOUTS CABLES WWIRES USE ONLY APPROVED TYPE LUBRICANT TO FACILITATE THE PULLING OF WIRE AND CABLE ALL BRANCH CIRCUIT CONDUCTORS SHALL BE COPPER 75 C TYPE THWN AND THHN ALL SIZES SHOWN ON THE DRAWINGS ARE BASED ON THHN COPPER WHENEVER MULTIPLE SETS OF FEEDERS ARE RUN TO A DEVICE OR PIECE OF EQUIPMENT EACH SET SHALL RUN IN ITS OWN CONDUIT MULTIPLE SETS OF FEEDERS ARE NOT PERMITTED IN A COMMON CONDUIT NO EXCEPTIONS ALUMINUM CONDUCTORS SHALL NOT BE USED ALL PHASE LEG NEUTRAL AND GROUND CONDUCTORS SHALL BE PROPERLY COLOR CODED IN ALL PANELS TROUGHS CABINETS AND BOXES IN ACCORDANCE WITH THE NEC ALL CONDUCTORS SHALL BE COPPER CONDUCTORS UP TO AND INCLUDING SIZE 6 AWG SHALL BE TYPE THWN THHN CONDUCTORS LARGER THAN SIZE 6 AWG SHALL BE TYPE THWN ALL RATED 600 VOLTS COPPER CONDUCTORS MINIMUM CONDUCTOR SIZE SHALL BE 12 AWG FOR POWER AND 14 AWG FOR CONTROL UNLESS OTHERWISE NOTED ALL FEEDER WIRING RUN WITHIN THE BUILDING SHALL BE INSTALLED IN ELECTRICAL METALLIC TUBING EMT GROUNDING GROUNDING OF THE NON CURRENT CARRYING METALLIC PARTS OF ALL ELECTRICAL EQUIPMENT AND ENCLOSURES INCLUDING CONDUITS SUPPORTS CABINETS TRANSFORMERS MOTOR FRAMES SWITCHGEAR ENCLOSURES CONTROL PANELS ETC WHICH ARE INSTALLED OR CONNECTED UNDER THIS CONTRACT SHALL BE PROPERLY CONNECTED TO THE GROUNDING SYSTEM REGARDLESS OF
7. DATE 06 03 2015 DRAWN BY AMP PERTH AMBOY NJ 08862 PERTH AMBOY MONMOUTH COUNTY NEW JERSEY DESIGNED BY AMP CHECKED BY AHG SCALE PROJECT NUMBER FIELD BOOK SHEET ss AUTOMATIC TRANSFER SWITCH SPECIFICATIONS PART 1 GENERAL 1 01 SCOPE A FURNISH AND INSTALL AUTOMATIC TRANSFER SWITCH ATS WITH NUMBER OF POLES AMPERAGE VOLTAGE WITHSTAND AND CLOSE ON RATINGS AS SHOWN ON THE PLANS AUTOMATIC TRANSFER SHALL CONSIST OF AN INHERENTLY DOUBLE THROW POWER TRANSFER SWIITCH MECHANISM AND A MICROPROCESSOR CONTROLLER TO PROVIDE AUTOMATIC OPERATION ALL TRANSFER SWITCHES AND CONTROLLERS SHALL BE THE PRODUCTS OF THE SAME MANUFACTURER B PROVIDE RELAYS AS REQUIRED FOR TIME DELAY ON OF MECHANICAL EQUIPMENT AND LOAD SHED 1 02 CODES AND STANDARDS THE AUTOMATIC TRANSFER SWITCHES AND CONTROLS SHALL CONFORM TO THE REQUIREMENTS OF A UL 1008 STANDARD FOR TRANSFER SWITCH EQUIPMENT B IEC 947 6 1 LOW VOLTAGE SWITCHGEAR AND CONTROL GEAR MULTIFUNCTION EQUIPMENT AUTOMATIC TRANSFER SWITCHING EQUIPMENT C NFPA 70 NATIONAL ELECTRICAL CODE D NFPA 110 EMERGENCY AND STANDBY POWER SYSTEMS E IEEE STANDARD 446 IEEE RECOMMENDED PRACTICE FOR EMERGENCY AND STANDBY POWER SYSTEMS FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS F NEMA STANDARD ICS10 1993 FORMERLY ICS2 447 AC AUTOMATIC TRANSFER SWITCHES G UL 508 INDUSTRIAL CONTROL EQUIPMENT 1 03 ACCEPTABLE MANUFACTURERS AUTOMATIC TRANSFER SWITCHES SHALL BE ASCO 3000
8. NOT TO SCALE AMIN H GOMAA PE DRAWN BY CHECKED BY FIELD BOOK SHEET PROFESSIONAL ENGINEER NJ LIC No 24GE04842100 AMP AHG E 100 COPYRIGHT 013 FRENCH amp PARRELLO ASSOCIATES PA THE COPYING OR REUSE OF THIS DOCUMENT OR PORTIONS THEREOF WITHOUT THE WRITTEN PERMISSION OF FRENCH amp PARRELLO ASSOCIATES PA IS PROHIBITED DUE TO INHERENT ERRORS IN REPRODUCTION METHODS ERRORS MAY OCCUR WHEN SCALING THIS DRAWING 1 4 FRENCGH S PARRELLO Hawetstown NJ STANDYBY GENERATOR INSTALLATION a ssociATrEs j New York NY 881 AMBOY AVENUE PERTH AMBOY NJ 08862 PERTH AMBOY ram No Revision s 5 12 OC T amp B EW Corporate Office ELECTRICAL SITE PLAN _ 1800 Route 34 Suite 101 AND DETAILS Wall NJ 07719 N 7392 312 9800 HOUSING AUTHORITY CITY OF PERTH AMBOY Regional Offices Revised By Checked By O WKW680016805 Paha Adminstration BuildingX6805 001 Generator RelocationCADDINDWCG16805 001 E101 dwg E101 36 _ FIELD _ 36 _ MIN VERIFY MIN s KEY NOTES 36 i MIN NEW PAD MOUNTED STANDBY GENERATOR FIELD e NEW EXTERIOR AUTOMATIC TRANSFER SWITCH IN NEMA 3R VERIFY WEATHERPROOF LOCKING ENCLOSURE O EXISTING GAS METER LOCATION MIN EXISTING PANEL P 1 EXISTING PANEL L 1 EXISTING GAS METER TO BE REMOVED AND REPLACED WITH NEW 1 PSI GAS METER COORDINATE METER UPGRADE AND GAS SERVICE WITH CARL NIEL
9. OC c GNO WHITE 2 q TYP d EGC GREEN lt 3 REFER TO NATIONAL ELECTRICAL CODE GROUNDING ELECTRODE CONDUCTORS TABLE 2008 NEC 250 66 AND N q 6 16 OC EQUIPMENT GROUNDING CONDUCTORS TABLE 2008 NEC 250 122 FOR SIZING OF GROUNDING AND BONDING 9 g GROUT SOLID S ITE PLAN KEY NOTES CONDUCTORS INDICATED ABOVE E REINF 2 O PROPOSED GENERATOR LOCATION FIELD COORDINATE EXACT 2 8 CMU BLOCK PLACEMENT PRIOR TO CONSTRUCTING NEW PAD COORDINATE PAD NON SE PA RATELY D E R IVE D O EN E RATOR ASTM G90 INSTALLATION WITH SLOPE OF GRADE AND INCREASE PAD DEPTH AS nx a FOR SLAB REINFORCING REQUIRED TO ACCOMMODATE SLOPE SYSTEM WITH 3 POLE ATS 11 hi GENERATOR PAD DETAIL ARIVILCA ER AYPA GRADE 2 JOINT FILLER NOT TO SCALE 2227 EE lt lt 3 2 36 ___ FIELD VERIFY _ 36 2 N MIN T MINI La 12 ORNAMENTAL FENCE AND GATE BY MASTER WIRE MFG E POWELSTOMATCH 2 36 BLACK 3 4 X 14 GAUGE s VERTICAL BARS 211 MIN 1 PICKETS 2 1 2 POSTS WITH l L FIELD VERIFY NEW 80 KW PA N GENERATOR a 2 P z 4 36 MIN Al L 8 CMU BLOCK WALLS ON THREE 3 SIDES WITH SYNERGY COATING COATING AS SELECTED BY OWNER GENERATOR SURROUND ENCLOSURE DETAIL NOTTOSCALE 5bblpb UUUuUuUuUuUuUaUaU U UzuUuUuUUzC sC Ts C U U a a 1 5 1 5 S 3 GENERATOR SURROUND FOUNDATION DETAIL wa woa
10. 400A INTERRUPTING RATING EXISTING KA SYM FED FROM UTILITY IRANSFORMER TOTAL PHASE NOTES 1 EXISTING NEMA 3R SQUARE D I LINE PANELBOARD FIELD VERIFY EXACT BRANCH BREAKER SIZES AND SHORT CIRCUIT RATING 2 BOLT ON BREAKERS ONLY 3 CONTRACTOR IS RESPONSIBLE TO COORDINATE THE SHORT CIRCUIT RATING PRIOR TO PURCHASING ANY EQUIPMENT 4 ALL WIRE SIZES ARE BASED ON 75 DEGREE WIRE JOB NAME PERTH AMBOY HA RATING 240 120V 3W 1PH 225A CIRCUIT DESCRIPTION EXISTING PANEL P 1 EXISTING JOB NO 6805 001 LOCATION MAIN ELECTRIC CLOSET BRANCH LOAD POLE CIRCUIT CKT CIRCUIT KVA DESCRIPTION NO EXISTING INSTA HOT HEATER JOB NAME PERTH AMBOY HA RATING 240 120V 3W 1PH 225A CIRCUIT DESCRIPTION EXISTING PANEL P 2 EXISTING POLE LOAD BKR BRANCH A B KVA CIRCUIT 0 0 2 40 EXISTING JOB NO 6805 001 LOCATION STORAGE CLOSET POLE CIRCUIT CKT DESCRIPTION NO 2 2 ACC 7 BRANCH CIRCUIT EXISTING EXISTING BRANCH CIRCUIT WATER HEATER EXISTING EXISTING AC 2 EXISTING EXISTING EXISTING AC CONDENSER EXISTING HEATER 2 HEATER 1A EXISTING EXISTING BOARD ROOM RECEPT EM LTG CORRIDOR EXISTING EXISTING OFFICE RECEPTACLES CORRIDOR LIGHTING STAFF LOUNG LIGHTING EXISTING EXISTING EXISTING RANGE OFFICE LIGHTING EXISTING EXISTING LIGHTING OFFICE LIGHTING EXISTING EXISTING MICROWAVE OFFICE LIGHTING
11. B OPERATING TRANSFER SWITCH CONSISTING OF SINGLE SOLENOID ELECTRICALLY OPERATED MECHANICALLY HELD C SOLDERLESS CONNECTORS FOR NORMAL SOURCE CABLES EMERGENCY SOURCE CABLES LOAD CABLES AND SOLID NEUTRAL BAR D HIGH FAULT WITHSTANDING CAPACITY E VOLTAGE MONITORING OF EACH PHASE OF NORMAL SOURCE FULL PROTECTION ADJUSTABLE 70 90 F VOLTAGE OF EMERGENCY TRANSFER 80 RATED G FREQUENCY OF EMERGENCY TRANSFER 80 OF RATED H VOLTAGE AND FREQUENCY MONITORING OF ONE PHASE OF EMERGENCY SOURCE l TIME DELAY ENGINE STARTING ADJUUSTABLE 0 TO 10 SECONDS J ENGINE MINIMUM RUN 10 MINUTES ADJUSTABLE K RETURN TO UTILITY DELAY 380 SECONDS ADJUSTABLE L ENGINE COOL DOWN TIMER 10 MINUTES ADJUSTABLE M ENGINE WARM UP 30 SECONDS ADJUSTABLE OVERRIDE SWITCH FOR NO DELAY N TIME DELAY NEUTRAL 0 OR 5 SECONDS SWITCH SELECTABLE O THREE POSITION MODE SELECTOR SWITCH ON THE FACE OF THE ENCLOSURE MARKED AUTO TEST AND FAST TEST P FAST TEST MODE RESETS ENGINE MINIMUM RUN TO 10 SECONDS ENGINE COOL DOWN TO 0 SECONDS AND RETURN TO UTILITY 0 TO 5 SECONDS Q SELF CHECK BUILT IN AT START UP ROUTINE CHECK OF ATS CIRCUITS LEDS SHALL FLASH TO CONFIRM INTEGRITY R EXERCISER 7 DAYS FROM INITIAL COMMAND S TRANSFER LOAD WHEN EXERCISING ON OFF SWITCH T THREE PILOT LIGHTS ON FACE OF ENCLOSURE INDICATING SOURCE TO WHICH THE ATS IS CONNECTED U AUXILIARY FORM C CONTACTS FOR NORMAL AND EMERGENCY
12. C CONTROLLERS THAT REQUIRE MULTIPLE SCREENS TO DETERMINE SYSTEM STATUS OR DISPLAY CODED SYSTEM STATUS MESSAGES WHICH MUST BE EXPLAINED BY REFERENCES IN THE OPERATOR S MANUAL ARE NOT PERMISSIBLE F D SELF DIAGNOSTICS THE CONTROLLER SHALL CONTAIN A DIAGNOSTIC SCREEN FOR THE PURPOSE OF DETECTING SYSTEM ERRORS THIS SCREEN SHALL PROVIDE INFORMATION ON THE STATUS INPUT SIGNALS TO THE CONTROLLER WHICH MAY BE PREVENTING LOAD TRANSFER COMMANDS FROM BEING COMPLETED F E COMMUNICATIONS INTERFACE THE CONTROLLER SHALL BE CAPABLE OF INTERFACING THROUGH AN OPTIONAL SERIAL COMMUNICATION MODULE WITH A NETWORK OF TRANSFER SWITCHES LOCALLY UP TO 4000 FT OR REMOTELY THROUGH MODEM SERIAL COMMUNICATIONS STANDARD SOFTWARE SPECIFIC FOR TRANSFER SWITCH APPLICATIONS SHALL BE AVAILABLE BY THE TRANSFER SWITCH MANUFACTURER THIS SOFTWARE SHALL ALLOW FOR THE MONITORING CONTROL AND SETUP OF A IHE ATS MANUFACTURER SHALL CERTIFICATION VERIFYING QUALITY ASSURANCE IN DESIGN DEVELOPMENT PRODUCTION INSTALLATION AND SERVICING IN ACCORDANCE WITH ISO 9001 4 03 SERVICE REPRESENTATION MAINTAIN A NATIONAL SERVICE ORGANIZATION OF COMPANY EMPLOYED PERSONNEL LOCATED THROUGHOUT THE CONTIGUOUS UNITED STATES THE SERVICE CENTER S PERSONNEL MUST BE FACTORY TRAINED AND MUST BE ON CALL 24 HOURS A DAY 365 DAYS A YEAR B THE MANUFACTURER SHALL MAINTAIN RECORDS OF EACH SWITCH BY SERIAL NUMBER FOR A MINIMUM OF 20 YEARS O 6KAV680016805 Paha Adminstratio
13. CONNECT TEST AND LEAVE READY FOR OPERATION D THE WORK CALLED FOR ON THE DRAWINGS AND SPECIFICATIONS HEREIN SHALL BE COORDINATED WITH THE STRUCTURE AND WORK OF ALL OTHER TRADES AND SHALL BE SO ARRANGED THAT THERE WILL BE NO DELAY IN THE PROPER INSTALLATION AND COMPLETION OF ANY PART OR PARTS OF EACH PERSPECTIVE WORK WHEREIN IT MAY BE INTERRELATED WITH THAT OF THIS CONTRACT SO THAT GENERALLY ALL WORK CAN PROCEED IN ITS NATURAL SEQUENCE WITHOUT UNNECESSARY DELAY E REFER TO OTHER ENGINEERING DRAWINGS FOR ALL NECESSARY FIRE DAMPERS ALARMS SMOKE DETECTORS AND FIRE COMMUNICATIONS EQUIPMENT AND INSTALL PER ALL APPLICABLE CODES AGENCIES AND LOCAL LAWS F WHERE EXISTING POWER CIRCUITS HAVE BEEN DISTURBED ALL COSTS FOR RECIRCUITING OF SAME IS TO BE INCLUDED G SHOP DRAWINGS AND DATA SHEETS ARE REQUIRED FOR ASSEMBLIES AND EQUIPMENT THEY SHALL PROVIDE ALL PERTINENT DATA AND INFORMATION NECESSARY TO EVALUATE EACH ITEM IRRELEVANT INFORMATION ON DRAWINGS AND DATA SHEETS SHALL BE COMPLETELY MARKED OUT LEAVING ONLY DATA THAT PERTAINS TO THE ITEMS SUBMITTED FOR APPROVAL DRAWINGS AND DATA SHEETS SHALL SHOW a PRINCIPAL DIMENSIONS AND DETAILS OF CONSTRUCTION b WEIGHTS OF PRINCIPAL PARTS AND TOTAL WEIGHTS WITH INFORMATION REQUIRED FOR THE DESIGN OF SUPPORTS AND FOUNDATIONS c PERFORMANCE DATA d UNDERWRITERS LABEL AND OTHER AUTHORITIES HAVING JURISDICTION OF EQUIPMENT REQUIRING LABELS e ALL MANUFACTURER S TEST REPORTS THAT MAY H
14. EXISTING EXISTING EXISTING LOAD BOARD LIGHTING EXISTING EXISTING OFFICE LIGHTING BOARD LIGHTING EXISTING EXISTING CASHIER RECEPTACLE OFFICE LIGHTING EXISTING EXISTING COPIER RECEPTACLE CASHIER LIGHTING EXISTING EXISTING EXISTING LOAD CORRIDOR LIGHTING EXISTING EXISTING EXISTING LOAD OFFICE LIGHTING EXISTING EXISTING EXISTING LOAD EM EXIT LIGHTING OFFICE LIGHTING EXISTING EXISTING EXISTING NATER HEATER PANEL TYPE NEMA 1 MOUNTING SURFACE MAIN CIRCUIT BREAKER 200A INTERRUPTING RATING EXISTING KA SYM FED FROM MDP TOTAL PHASE NOTES 1 EXISTING CUTLER HAMMER TYPE PB PANELBOARD EXISTING MCB SHORT CIRCUIT RATING 10KA RMS SYM AMPS 2 BOLT ON BREAKERS ONLY 3 CONTRACTOR IS RESPONSIBLE TO COORDINATE THE SHORT CIRCUIT RATING PRIOR TO PURCHASING ANY EQUIPMENT 4 ALL WIRE SIZES ARE BASED ON 75 DEGREE WIRE 5 FIELD VERIFY BREAKER SIZE JOB NAME PERTH AMBOY HA EXISTING PANEL L 1 RATING 240 120V 3W 1PH 100A EXISTING CKT CIRCUIT BRANCH POLE LOAD B NO DESCRIPTION KVA CIRCUIT 1 PANEL L 1 NOTE 5 RAWL SPACEHEATIER JOB NO 6805 001 LOCATION MAIN ELECTRIC CLOSET A B BRANCH OAD POLE CIRCUIT CKT CIRCUIT KVA DESCRIPTION NO RECEPTACLES KR OFFICE AND ATTIC LTG 1 20 EXISTING EMERGENCY LIGHTING 1 20 EXISTING EXISTING LOAD 1 20 EXISTING 0 0 EXISTING BKR
15. FOR BOTH NORMAL amp EMERGENCY TO PROVIDE DIGITAL READOUT OF VOLTAGE ON ALL 3 PHASES FREQUENCY AND PHASE ROTATION F THE CONTROLLER SHALL INCLUDE A USER SELECTABLE ALGORITHM TO PREVENT REPEATED TRANSFER CYCLING TO A SOURCE ON AN INSTALLATION WHICH EXPERIENCES PRIMARY SIDE SINGLE PHASE FAILURES ON A GROUNDED WYE GROUNDED WYE TRANSFORMER WHICH REGENERATES VOLTAGE WHEN UNLOADED THE ALGORITHM SHALL ALSO INHIBIT RETRANSFER TO THE NORMAL UTILITY SOURCE UPON DETECTION OF A SINGLE PHASING CONDITION UNTIL A DEDICATED TIMER EXPIRES THE ALTERNATE SOURCE FAILS OR THE NORMAL SOURCE FAILS COMPLETELY AND IS RESTORED DURING THIS TIME DELAY PERIOD THE TIME DELAYS ASSOCIATED WITH THIS FEATURE SHALL BE ADJUSTABLE BY THE USER THROUGH THE CONTROLLER KEYPAD AND LCD 3 03 TIME DELAYS A B C AN ADJUSTABLE TIME DELAY OF 0 TO 6 SECONDS SHALL BE PROVIDED TO OVERRIDE MOMENTARY NORMAL SOURCE OUTAGES AND DELAY ALL TRANSFER AND ENGINE STARTING SIGNALS CAPABILITY SHALL BE PROVIDED TO EXTEND THIS TIME DELAY TO 60 MINUTES BY PROVIDING AN EXTERNAL 24 VDC POWER SUPPLY A TIME DELAY SHALL BE PROVIDED ON TRANSFER TO EMERGENCY ADJUSTABLE FROM 0 TO 60 MINUTES FOR CONTROLLED TIMING OF TRANSFER OF LOADS TO EMERGENCY TWO TIME DELAY MODES WHICH ARE INDEPENDENTLY ADJUSTABLE SHALL BE PROVIDED ON RE TRANSFER TO NORMAL ONE TIME DELAY SHALL BE FOR ACTUAL NORMAL POWER FAILURES AND THE OTHER FOR THE TEST MODE FUNCTION THE TIME DELAYS SHALL BE ADJUSTABLE F
16. FROM THE ENGINEER FINISH AND PAINT ALL PATCHED SURFACES WITH TWO COATS OF PAINT TO MATCH EXISTING SURFACES AS CLOSELY AS POSSIBLE Corporate Office ELECTRICAL SYMBOLS NOTES AND SEAL OPENINGS VERMIN AND WATER PROOF AND MAINTAIN FIRE RATING USE 1800 Route 34 Suite 101 SINGLE LINE DIAGRAM SPECIFIED TECHNOLOGIES INC SPECSEAL SERIES LCI Wall NJ 07719 732 312 27 ALL PENETRATIONS IN FOUNDATION WALLS INCLUDING SLAB PENETRATIONS Gi 1 FOUSING AUTHORITY CITY OF PERTI AMBDSY SHALL BE SUBSTANTIALLY SEALED BY UTILIZING A NON CRACKING Hackettstown NJ POLYURETHANE OR SIMILAR CAULK OR EQUIVALENT TO CLOSE OFF THE SOIL FHESCHISPSrDErED New York NY SIANDYDBY GENERATOR INSTAtL ATION GAS ENTRY ROUTES ALL CONDUITS IN THE SPACE BELOW THE FOUNDATION 881 AMBOY AVENUE FLOOR WHICH PENETRATE THESE BARRIERS SHALL HAVE THREADED OR PERTH AMBOY NJ 08862 SOLVENTED FITTINGS 6 25 A5 ADDENDA NO 1 AMP AMP PERTH AMBOY 28 ALL NEW RACEWAY WIRING AND CABLE IN NEW AND EXISTING FINISHED No Date Revision Revised By Checked By MONMOUTH GOUNTY NEW JERSEY SPACES SHALL BE RUN CONCEALED IN NEW AND EXISTING CONSTRUCTION UNLESS OTHERWISE INDICATED CUT AND PATCH AS REQUIRED PROVIDE DATE DESIGNED BY SCALE PROJECT NUMBER FIELD BOOK SHEET ss AMIN H GOMAA PE DRAWN BY CHECKED BY PROFESSIONAL ENGINEER NJ LIC No 24GE04842100 AMP AHG COPYRIGHT 013 FRENCH amp PARRELLO ASSOCIATES PA THE COPYING OR REUSE OF THIS DOCUMENT OR PORTIONS THEREOF
17. INSTALLATION GUIDE 7 DRAWING AND WIRING SCHEMATICS OF PROPOSED ASSEMBLY BATTERY RACK MUFFLER AND FLEXIBLE FITTINGS 8 GENERATOR ENCLOSURE DIMENSIONAL DETAILS NOISE RATINGS ETC 1 STANDBY KW 80 KW 2 POWER FACTOR 0 80 3 FREQUENCY 60 HZ THE SPECIFIED STANDBY KW SHALL BE FOR CONTINUOUS ELECTRICAL SERVICE INTERRUPTION OF THE NORMAL UTILITY SOURCE PER NEMA STANDARDS THE ENGINE SHALL BE WATER COOLED OF FOUR STROKE CYCLE DESIGN COMPRESSION IGNITED RATED FOR CONTINUOUS STANDBY APPLICATION IT SHALL PRODUCE SUFFICIENT HORSEPOWER TO ACHIEVE RATINGS AS SHOWN ON THE DRAWING WHILE DRIVING ALL ACCESSORIES AND PARASITIC LOADS SUCH AS FUEL LUBE OIL AND JACKET WATER PUMPS THE ENGINE CYLINDERS SHALL BE EQUIPPED WITH REPLACEABLE CYLINDER LINERS AND SHALL BE FULLY WATER COOLED PISTONS SHALL BE ONE PIECE THREE RING DESIGN CONNECTING RODS SHALL BE FORGED HARDENED AND PEENED FOR INCREASED STRENGTH MAIN AND ROD BEARINGS SHALL BE OF ALUMINUM CONSTRUCTION WITH COPPER BONDING TO THE LEAD TIN OVERLAY SUPER FINISHED FOR UNIFORM FILM THE ENGINE SHALL INCORPORATE ONE PIECE HIGH STRENGTH CYLINDER HEADS THE LUBE OlL FILTER SYSTEM SHALL BE OF THE FULL FLOW TYPE WITH A BUILT IN BYPASS THE CYLINDER BLOCK SHALL BE OF SINGLE PIECE CONSTRUCTION AND CONSTRUCTED IN SUCH A WAY THAT LINER SHALL REST ON THE TOP OF THE BLOCK WITH A SPACER PLATE INSTALLED BETWEEN THE BLOCK AND CYLINDER HEAD EACH CYLINDER SHALL HAVE A CONTINUOUSLY PRESSURIZED OIL COOLING
18. L 30 20 20 0 0 EXISTING 0 0 EXISTING 1 1 RECEPTACLES LIGHTING GENERATOR BLOCK HEATER 1 1 5 20 NOTE 5 2 12 amp 1 12EG IN 3 4 C 1 5 EXISTING 20 1 RECEPTACLES GENERATOR BATTERY T 2 CHARGER HEATER NOTE 5 2 12 amp 1 12EG IN 3 4 C EXISTING 20 LIGHTING ALTERNATOR HEATER NOTE 5 1 0 20 2 12 amp 1 12EG IN 3 4 C SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE PANEL TYPE NEMA 1 MOUNTING SURFACE MAIN LUGS ONLY INTERRUPTING RATING EXISTING KA SYM FED FROM EXISTING PANEL P 1 TOTAL PHASE NOTES 1 EXISTING SQUARE D QO LOADCENTER EXISTING MCB SHORT CIRCUIT RATING 10KA RMS SYM AMPS 2 BOLT ON BREAKERS ONLY 3 CONTRACTOR IS RESPONSIBLE TO COORDINATE THE SHORT CIRCUIT RATING PRIOR TO PURCHASING ANY EQUIPMENT 4 ALL WIRE SIZES ARE BASED ON 75 DEGREE WIRE 4 PROVIDE NEW BREAKER IN EXISTING SPACE KEY NOTES s FURNISH AND INSTALL RELAYS AND DRY CONTACTS AS REQUIRED FOR LOAD SHEDDING OF AIR CONDITIONING HVAC EQUIPMENT PRIOR TO STARTUP COORDINATE EXACT REQUIREMENTS WITH THE EQUIPMENT VENDOR OR MANUFACTURER FIELD COORDINATE EXACT LOCATIONS OF EXISTING EQUIPMENT IN THE FIELD FIELD VERIFY EXISTING LOAD IF SERVES CONDENSING UNIT OR PACKAGED HVAC EQUIPMENT PROVIDE RELAY AND DRY CONTACTS FOR LOAD SHED AHU 7 2 40 E
19. MUELLER CO H NATIONAL METER I NORDSTROM VALVES INC J OLSON TECHNOLOGQIES INC 3 GAS VALVES 2 1 2 INCH NPS DN65 AND LARGER A CORE INDUSTRIES INC MUELLER STEAM SPECIALTY DIV B HUBER J M HUBER CORP FLOW CONTROL DIV C MILLIKEN VALVE CO INC D NORDSTROM VALVES INC E OLSON TECHNOLOGIES INC F XOMOX CORP 2 2 PIPES AND TUBES A ALL EXPOSED PIPING AND FITTINGS SHALL BE GALVANIZED AND PAINTED TO MATCH B STEEL PIPE ASTM A 53 TYPE E ELECTRIC RESISTANCE WELDED OR TYPE S SEAMLESS GRADE B SCHEDULE 40 BLACK C PE PIPE ASTM D 2513 2 3 PIPE AND TUBE FITTINGS A MALLEABLE IRON THREADED FITTINGS ASME B16 3 CLASS 150 STANDARD PATTERN WITH THREADED ENDS CONFORMING TO ASME B1 20 1 B UNIONS ASME B16 39 CLASS 150 MALLEABLE IRON WITH BRASS TO IRON SEAT GROUND JOINT AND THREADED ENDS CONFORMING TO ASME B1 20 1 C STEELFITTINGS ASME B16 9 WROUGHT STEEL BUTT WELDING TYPE AND ASME B16 11 FORGED STEEL D BRONZE FLANGES AND FLANGED FITTINGS ASME B16 24 CLASS 150 E CAST IRON FLANGES AND FLANGED FITTINGS ASME B16 1 CLASSES 125 AND 250 2 4 JOINING MATERIALS A BRAZING FILLER METALS AWS A5 8 SILVER CLASSIFICATION BAG 1 FILLER METAL CONTAINING PHOSPHORUS IS PROHIBITED B JOINT COMPOUND AND TAPE SUITABLE FOR NATURAL GAS C GASKET MATERIAL THICKNESS MATERIAL AND TYPE SUITABLE FOR NATURAL GAS 2 5 VALVES A MANUAL VALVES CONFORM TO STANDARDS LISTED OR WHERE APPROPRIATE TO
20. NORMAL STARTING CURRENTS AND SHALL FRENCH ES PARRELLO Harxettstown NJ PARAMETER SOURCES DROPOUT TRIP PICKUP RESET NOT REQUIRE EXTERNAL CONTROL OF POWER SOURCES THE INPHASE New York NY STANDYBY GENERATOR INSTALLATION SPE EYEKEEFESEESI ss S s S TEST aSEEI MONITOR SHALL BE SPECIFICALLY DESIGNED FOR AND BE THE PRODUCT 881 AMBOY AVENUE UNDERVOLTAGE N amp E32 70 98 85 100 OF THE ATS MANUFACTURER THE INPHASE MONITOR SHALL BE EQUAL TO PERTH AMBOY NJ 08862 OVERVOLTAGE N amp E3 102 115 2 BELOW TRIP ASCO FEATURE 27 i UNDERFREQUENCY N amp E 85 99 90 100 1 5 2S415 ADDENDANO 1 PERTH AMBOY OVERFREQUENY N amp E 102 10 2 BELOW TRIP s s i s VOLTAGE UNBALANCE N amp E 5 TO 20 1 BELOW DROPOUT i 1 PROJECT NUMBER 6805 001 AS NOTED FIELD BOOK SHEET E 302 06 03 2015 AMP AMIN H GOMAA PE CHEGKED BY PROFESSIONAL ENGINEER NJ LIC No 24GE04842100 AMP AHG DRAWN BY COPYRIGHT 013 FRENCH amp PARRELLO ASSOCIATES PA THE COPYING OR REUSE OF THIS DOCUMENT OR PORTIONS THEREOF WITHOUT THE WRITTEN PERMISSION OF FRENCH amp PARRELLO ASSOCIATES PA IS PROHIBITED DUE TO INHERENT ERRORS IN REPRODUCTION METHODS ERRORS MAY OCCUR WHEN SCALING THIS DRAWING
21. OF THIS CONTRACT OWNER OR PROJECT CONTROL SYSTEM FOR LOAD SHEDDING AND STAGGERED STARTUP OF FURNISHED BY OTHERS WEATHERPROOF MECHANICAL EQUIPMENT PROVIDE ASCO ACCESSORIES AS REQUIRED GROUND FAULT 21 mQGROUNDING AND BONDING SHALL MEET NEC AND EQUIPMENT SYSTEM UPON AWARD OF CONTRACT AND SUBSEQUENT APPROVAL OF SHOP INTERRUPTER MANUFACTURER S REQUIREMENTS DRAWINGS BY ENGINEER OF RECORD THE CONTRACTOR SHALL FILL OUT O EXISTING CONDUIT AND 600 KCMIL FEEDERS TO BE INTERCEPTED AND FILE AIR PERMIT APPLICATIONS IN A TIMELY MANNER FOR GENERATORS REMOVED AND REROUTED AS REQUIRED FIELD COORDINATE EXACT 22 CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF DEBRIS THE CONTRACTOR SHALL PAY ALL FEES FOR THE PERMITS AND INSPECTIONS FEEDER SIZES AND QUANTITIES GENERATED BY HIS WORK AND WORKERS AT THE END OF EACH WORKING PROVIDE THE OWNER AND ENGINEER EACH WITH A COPY OF FILLED OUT DAY AND FOR GENERAL GOOD HOUSEKEEPING BY HIS WORKERS FORMS PRIOR TO MAILING CONTRACTOR MUST SECURE PERMIT PRIOR TO S TWO 2 1 EMPTY CONDUITS FOR GENERATOR CONTROL WIRING PER CONTRACTOR SHALL PROVIDE REQUIRED REFUSE CONTAINERS PROJECT CLOSEOUT SEND FORMS ALONG WITH NJDEP S REQUIRED FEE TO MANUFACTURER S WRITTEN INSTALLATION INSTRUCTIONS DEVICE LEGEND NOTES NEW JERSEY DEPARTMENT OF ENVIRONMENTAL PROTECTION AND ENERGY kizuuus u s a ss 23 DISCONNECT AND REMOVE FROM THE PREMISES OR STORE ON THE BUREAU OF SOURCE REVIEW CN 27 TRENTON NEW JERSEY 08625 0027 TO HEATERS AND BATTE
22. READOUT METERS AND SELF DIAGNOSTIC CAPABILITY SHALL BE PROVIDED SHOCK MOUNTED AND VIBRATION ISOLATED ON THE GENERATOR CONTROL PANEL SHALL INCLUDE 1 TRUE RMS READING METERS FOR AMPS AND VOLTS A PHASE SELECTOR SWITCH FOUR POSITION FREQUENCY METER VOLTAGE ADJUST RHEOSTAT OIL PRESSURE GAUGE WATER TEMPERATURE GAUGE BATTERY DC VOLTMETER TACHOMETER AUTO START STOP CONTROL MODULE OVERCRANK 4 POSITION ENGINE CONTROL SWITCH FOR STOP OFF RESET MANUAL AUTO CYCLE CRANKING COOLDOWN TIMER AND EMERGENCY STOP PUSHBUTTON PROVIDE AN ALARM MODULE WITH FLASHING LEDS AND HORN TO ANNUNCIATE THE FOLLOWING A HIGH COOLANT TEMPERATURE ALARM B LOW COOLANT TEMPERATURE ALARM C LOW OIL PRESSURE ALARM D LOW DC VOLTS ALARM E SYSTEM NOT INAUTOMATIC F LOW FUEL LEVEL G FUEL TANK LEAK H ENGINE RUN CONTACT l AUXILIARY RELAY J ALL NECESSARY CONTROL WIRING FUSES FUSE BLOCKS TERMINAL BLOCKS NAMEPLATES FAULT CONTACTS AUXILIARY CONTACTS METERING CONTROL TRANSFORMERS K PROVIDE A REMOTE ANNUNCIATOR PANEL WITH ALARM INDICATING LIGHTS AND ALARM HORN WITH TEST SWITCH AND SILENCE BUTTON FOR THE FOLLOWING ALARM CONDITIONS A LOW OIL PRESSURE B HIGH WATER TEMPERATURE C OVERSPEED D BATTERY CHARGER MALFUNCTION E OVERCRANK F GENERATOR RUNNING G SYSTEM NOT INAUTO THE ENGINE AND GENERATOR SHALL BE FACTORY MOUNTED ON A TORSIONALLY STIFF BASE FABRICATED FROM CHANNEL OR I BEAM TO INSURE ADEQUATE MOUNTING SURFACE CONTACT AND MIN
23. THE BASIC CONTRACT IF THERE ARE ANY DOUBTS AS TO WORK REQUIRED THE CONTRACTOR SHALL OBTAIN A CLARIFICATION FROM THE ENGINEER IN THE BID STAGE b THE CONTRACT DRAWINGS SHOW THE INTENDED LOCATION OF THE EQUIPMENT HOWEVER THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY MINOR ADJUSTMENTS OR RELOCATIONS NECESSARY DUE TO CHOICE OF EQUIPMENT AND COORDINATION CONFLICTS ALL EQUIPMENT RELOCATIONS MUST BE SUBMITTED TO THE ENGINEER FOR APPROVAL c THE PROJECT DRAWINGS THIS SPECIFICATION AND OTHER RELATED DOCUMENTS ARE COMPLEMENTARY ITEMS REQUIRED BY ONE SHALL DESIGNATE REQUIREMENT BY THE OTHER WHETHER EXPLICITLY STATED OR NOT WHERE DOCUMENTS CONFLICT THE WORK OF THE MORE STRINGENT NATURE SHALL BE REQUIRED d COOPERATION AND COORDINATION WITH UTILITIES OWNER AND OTHER SUBCONTRACTORS IS MANDATORY e EXISTING WORK AND UTILITIES WHICH ARE DAMAGED OR DISTURBED DUE TO ANY PHASE OF OPERATIONS SHALL BE RESTORED TO THE SATISFACTION OF FPA THE OWNER AND THE GOVERNING AUTHORITIES f PROCUREMENT AND INSTALLATION OF MATERIALS PRODUCTS AND EQUIPMENT SHALL BE COORDINATED WITH THE WORK OF THE OTHER TRADES INCLUDING ALL WORK SHOWN ON THE PLUMBING ELECTRICAL FIRE PROTECTION AND ARCHITECTURAL DRAWINGS B CLEARANCES FOR WORKING SPACE AND MAINTENANCE SHALL BE MAINTAINED AS REQUIRED BY CODE AND OR MANUFACTURER S REQUIREMENT WHICHEVER IS MORE STRINGENT C PROVIDE AND OR FURNISH AND INSTALL MEANS PURCHASE ARRANGE DELIVERY UNLOAD INSTALL
24. ALLIC PIPING WIRE SHALL TERMINATE ABOVE GROUND AT EACH END OF THE NON METALLIC PIPING THE TRACER WIRE SIZE SHALL NOT BE LESS THAN 18AWG AND THE INSULATION TYPE SHALL BE SUITABLE FOR DIRECT BURIAL VALVE APPLICATIONS A USE GAS VALVES OF SIZES INDICATED FOR GAS SERVICE PIPING METERS MAINS AND WHERE INDICATED PIPING INSTALLATIONS A INSTALL GAS PIPING AT UNIFORM GRADE OF 0 1 PERCENT SLOPE UPWARD TOWARD RISERS B USE ECCENTRIC REDUCER FITTINGS TO MAKE REDUCTIONS IN PIPE SIZES INSTALL FITTINGS WITH LEVEL SIDE DOWN CONNECT BRANCH PIPING FROM TOP OR SIDE OF HORIZONTAL PIPING INSTALL UNIONS IN PIPES 2 INCH NPS DN50 AND SMALLER ADJACENT TO EACH VALVE AT FINAL CONNECTION TO EACH PIECE OF EQUIPMENT AND ELSEWHERE AS INDICATED UNIONS ARE NOT REQUIRED ON FLANGED DEVICES E INSTALL DIELECTRIC FITTINGS UNIONS AND FLANGES WITH FERROUS AND BRASS OR BRONZE END CONNECTIONS SEPARATED BY INSULATING MATERIAL WHERE PIPING OF DISSIMILAR METALS IS JOINED F INSTALL DIELECTRIC FITTINGS UNIONS AND FLANGES WITH 2 FERROUS END CONNECTIONS SEPARATED BY INSULATING MATERIAL AT OUTLET FROM GAS METER AND WHERE INDICATED FOR FERROUS PIPING G INSTALL FLANGES ON VALVES SPECIALTIES AND EQUIPMENT HAVING 2 1 2 INCH NPS DN65 AND LARGER CONNECTIONS H PAINT ALL ABOVE GROUND PIPING TO MATCH EXISTING GAS PIPING WITH A MINIMUM OF 2 COATS OF EXTERIOR LATEX PAINT COLOR TO MATCH EXISTING EXPOSED STADIUM PIPING COLOR SUBMITTED TO MLS FOR R
25. ANSI Z221 15 B GAS STOPS 2 INCH NPS DN50 AND SMALLER AGA CERTIFIED BRONZE BODY PLUG TYPE WITH BRONZE PLUG BALL TYPE WITH CHROME PLATED BRASS BALL OR BUTTERFLY VALVE WITH STAINLESS STEEL DISC AND FLUOROCARBON ELASTOMER SEAL FOR 2 PSIG 13 8 KPA OR LESS NATURAL GAS INCLUDE AGA STAMP FLAT OR SQUARE HEAD OR LEVER HANDLE AND THREADED ENDS CONFORMING TO ASME B1 20 1 1 LOCKING DEVICE INCLUDE LOCKING TAMPERPROOPF FEATURE C GAS VALVES 2 INCH NPS DN50 AND SMALLER ASME B16 33 150 PSIG 1035 KPA WOG BRONZE BODY BRONZE PLUG STRAIGHTAWAY PATTERN SQUARE HEAD TAPERED PLUG TYPE WITH THREADED ENDS CONFORMING TO ASME B1 20 1 1 LOCKING DEVICE INCLUDE LOCKING TAMPERPROOPF FEATURE D GAS VALVES 2 1 2 INCH NPS DN65 AND LARGER MSS SP 78 CLASS 125 OR CLASS 175 WOG NONLUBRICATED PLUG TYPE WITH POLYTETRAFLUOROETHYLENE PTFE LINING OR SLEEVE SEMISTEEL BODY WRENCH OPERATED WITH FLANGED ENDS 1 LOCKING DEVICE INCLUDE LOCKING TAMPERPROOPF FEATURE PART 3 EXECUTION 3 1 PIPING APPLICATIONS A GENERAL FLANGES UNIONS TRANSITION AND SPECIAL FITTINGS AND VALVES WITH PRESSURE RATINGS SAME AS OR HIGHER THAN SYSTEM PRESSURE RATING MAY BE USED IN APPLICATIONS BELOW EXCEPT WHERE OTHERWISE INDICATED 1 COMPLY WITH INTERNATIONAL FUEL GAS CODE FOR INSTALLATION AND PURGING OF NATURAL GAS PIPING B LOW PRESSURE 0 5 PSIG 3 45 KPA OR LESS NATURAL GAS SYSTEMS USE THE FOLLOWING 1 1 INCH NPS DN25 AND SMAL
26. ATED LOAD ENGINE BHP AVAILABLE JACKET WATER HEAT REJECTION COOLING PUMP CHARACTERISTICS EXHAUST FLOW RATE AND TEMPERATURE AT RATED LOAD VENTILATION REQUIREMENTS COMBUSTION AIR REQUIREMENTS MAXIMUM ALLOWABLE AIR FLOW AND AMBIENT TEMPERATURE RESTRICTIONS EXHAUST BACK PRESSURE LIMITATION ROLLING AMPERE RATE FOR ELECTRIC STARTING LIQUID REFILL CAPACITIES GENERATOR EFFICIENCY AT 50 75 AND 100 LOAD GENERATOR SET VENTILATION REQUIREMENTS TIF HARMONIC WAVE DISTORTION DIRECT AXIS TRANSIENT REACTANCE X D DIRECT AXIS SUBTRANSIENT REACTANCE X D TYPE OF WINDING INSULATION GENERATOR TEMPERATURE RISE REGULATION CHARACTERISTICS GENERATOR TYPE OF CONSTRUCTION AND OVERSPEED CAPABILITIES AND SHORT CIRCUIT CURRENT CAPABILITY CURVES 2 STANDARD MANUFACTURER S PRINTED WARRANTY STATEMENT OF THE ENGINE AND GENERATOR SET SHOWING SINGLE SOURCE OF RESPONSIBILITY BY THE ENGINE MANUFACTURER 3 GENERATOR CONTROL PANEL EQUIPMENT AND FEATURES 4 ACCESSORY CATALOG CUTS INCLUDING THE FLEXIBLE EXHAUST COUPLING MUFFLER BATTERIES MAINLINE CIRCUIT BREAKER AND ENCLOSURE ENGINE MANUFACTURER S SHUTDOWN CONTACTORS FUEL LINES JACKET WATER HEATER FUEL DAY TANK AND VOLTAGE REGULATOR INCLUDE A DETAILED STATEMENT CONCERNING NON ENGINE GENERATOR SET MANUFACTURER S RESPONSIBILITY AND DURATION OF POLICY 5 SPARE PARTS LIST 6 MANUFACTURER S PART NUMBER FOR THE ENGINE AND GENERATOR OPERATION GUIDE PARTS BOOK SERVICE MANUAL WARRANTY POLICY AND
27. ATIONS AND NOT JUST THOSE COMMONLY O S 5 5 5 5 Oo 5 isi Es s 1 REFERRED TO AS A SINGLE TRADE DRAWING UNLESS SPECIFICALLY 23 FEET AND INTERNAL CRITICAL SILENCER PROVIDE ras ama ELECTRICAL CONTRACTOR RIGID GALVANIZED STEEL 20 WHERE EXISTING EQUIPMENT IS INDICATED TO BE CONNECTED OR IDENTIFIED ELSEWHERE AS WORK OF OTHER TRADES WHERE EQUIPMENT SIBIP H ATER BLOCK HEATER BATTEPY HEATER AND GHARGER EQUIPMENT GROUND SURGE PROTECTIVE DEVICE RECONNECTED TO NEW WIRING CONDUIT ETC THE CONTRACTOR SHALL REQUIRING WIRING IS SPECIFIED OR SHOWN ON DRAWINGS OTHER THAN EMERGENCY TRANSIENT VOLTAGE FABRICATE AND INSTALL THE NEW SYSTEM CONNECTIONS TO MATCH THE ELECTRICAL DRAWINGS OR INDICATED OR IMPLIED SUCH AS ON SHOP ELECTRICAL METALLIC SURGE SUPPRESSOR CONNECTION POINTS AND OTHER REQUIREMENTS OF THE EXISTING DRAWINGS SUBMITTED LATER THE CONTRACTOR CAN AND SHALL REQUEST s gt way O 1 TN sul ap BE B OSIS TUBING TIME CLOCK EQUIPMENT WHERE THE EXISTING EQUIPMENT MUST BE REMOVED AND DIRECTION REGARDING CIRCUIT SIZING PROTECTION AND ROUTING WHERE L P O EXISTING TO REMAIN UNLESS OTHERWISE NOTED REINSTALLED TO FACILITATE THE REMOVAL OF THE OLD CONNECTIONS AND NECESSARY BUT SHALL UNDERSTAND ALL NECESSARY WORK TO COMPLETE i ELECTRIC WATER COOLER VOLTS OR THE CONNECTION OF THE NEW MATERIAL THAT WORK SHALL BE A PART THE INSTALLATION SHALL BE PERFORMED AT NO ADDITIONAL COST TO THE a PROVIDE RELAYS MODULES AND DRY CONTRACTS TO GENERATOR FIRE ALARM WALL MOUNTED
28. AVE BEEN CONDUCTED AT THE FACTORY ON TRANSFORMERS AND INSULATION TESTS ON MEDIUM VOLTAGE CABLE INCLUDING HIGH POTENTIAL POWER AND POWER FACTOR TEST RESULTS f CERTIFIED PERFORMANCE GUARANTEES Il ALL CHANGES SHALL BE MADE THAT ARE NECESSARY FOR ADJUSTING SETTING AND BALANCING J PHASE ROTATION AT ALL BUSSES PANELS SWITCHGEAR ETC SHALL BE CHECKED TO SEE THAT IT CONFORMS WITH RECOGNIZED STANDARDS K BEFORE ENERGIZING ANY FACTORY FABRICATED EQUIPMENT INSPECT EACH UNIT IN DETAIL BOLTS AND CONNECTIONS SHALL BE TIGHT TORQUE TIGHT WHERE REQUIRED PER MANUFACTURERS SPECIFICATIONS COMPONENTS SHALL BE ALIGNED AND THE EQUIPMENT SHALL BE PLACED IN A SAFE OPERATIONAL CONDITION L THE COMPLETE ELECTRICAL SYSTEM SHALL BE FREE OF GROUNDS AND SHORT CIRCUITS IT SHALL OPERATE PROPERLY UNDER FULL LOAD CONDITIONS WITHOUT EXCESSIVE HEATING AT ANY POINT IN THE SYSTEM M OBTAIN ALL NECESSARY CONTROL WIRING DIAGRAMS FROM THE EQUIPMENT MANUFACTURER N PROVIDE ALL NECESSARY CONTROL CIRCUITS AND INTERLOCK WIRING BETWEEN UNITS O ANY BUILDING SERVICE SHUTDOWNS REQUIRED FOR THIS WORK SHALL BE REQUESTED IN WRITING BY THE ELECTRICAL CONTRACTOR AT LEAST 72 HOURS IN ADVANCE OF THE SHUTDOWN THE ELECTRICAL CONTRACTOR SHALL OBTAIN APPROVAL IN WRITING FROM THE OWNER PRIOR TO SHUTDOWN ANY SHUTDOWN AFFECTING THE NORMAL ELECTRICAL SERVICE OF ANY BUILDING OCCUPANTS SHALL BE DONE ON OVERTIME A A A A A INSTALL AND WIRE ALL CONTROL
29. CADD_NDWCG516805 001 E300 dwg E 300 ELECTRICAL SPECIFICATIONS 1 PATCHING AND CUTTING A PERFORM ALL CUTTING FITTING AND PATCHING WORK THAT MAY BE REQUIRED BY ITS WORK AND AS SHOWN OR REASONABLY IMPLIED BY THE DRAWINGS AND NOTES B ALL DAMAGED AREAS AND EXISTING AREAS EFFECTED BY DEMOLITION OR NEW CONSTRUCTION WORK SHOWN ON DRAWINGS SHALL BE PATCHED AS REQUIRED TO MATCH IMMEDIATE EXISTING ADJACENT AREAS IN MATERIAL FIRE RATING FINISH COLOR UNLESS OTHERWISE NOTED C THE ELECTRICAL CONTRACTOR IS TO REPLACE THE INTEGRITY OF RATED PARTITIONS COLUMNS AND BEAM FIREPROOFING EFFECTED BY ITS WORK REPLACEMENT TO COMPLY WITH LOCAL CODES D PROVIDE SUPPORTS TO ASSURE STRUCTURAL INTEGRITY OF SURROUNDINGS DEVICES AND METHODS TO PROTECT OTHER PORTIONS OF PROJECT FROM DAMAGE E EXECUTE WORK BY METHODS TO AVOID DAMAGE TO OTHER WORK AND WHICH WILL PROVIDE PROPER SURFACES TO RECEIVE PATCHING AND FINISHING 3 GENERAL A FURNISH AND INSTALL ALL ELECTRICAL WORK AS SHOWN ON THE DRAWINGS AND THESE SPECIFICATIONS HEREIN WORK INCLUDES THE FOLLOWING UNDERSTANDINGS a CONTRACT DRAWINGS ARE DIAGRAMMATIC AND INTENDED TO OUTLINE BASIC ENGINEERING AND SYSTEMS DESIGN THEREFORE DO NOT SHOW MINOR DETAILS AND ACCESSORIES BECAUSE A MINOR COMPONENT IS NOT SHOWN SHALL NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY FOR FURNISHING AND INSTALLING ALL SUCH ITEMS NECESSARY TO PROVIDE COMPLETE OPERATIVE AND PROPERLY INSTALLED SYSTEMS TO THE OWNER UNDER
30. CH amp PARRELLO ASSOCIATES PA THE COPYING OR REUSE OF THIS DOCUMENT OR PORTIONS THEREOF WITHOUT THE WRITTEN PERMISSION OF FRENCH amp PARRELLO ASSOCIATES PA IS PROHIBITED DUE TO INHERENT ERRORS IN REPRODUCTION METHODS ERRORS MAY OCCUR WHEN SCALING THIS DRAWING NATURAL GAS PIPING SPECIFICATIONS PART 1 GENERAL 1 1 SYSTEM PERFORMANCE REQUIREMENTS A MINIMUM WORKING PRESSURE RATINGS EXCEPT WHERE OTHERWISE INDICATED MINIMUM PRESSURE REQUIREMENTS ARE AS FOLLOWS 1 LOW PRESSURE NATURAL GAS PIPING 7 8 WC 2 MEDIUM PRESSURE NATURAL GAS PIPING 2 PSI 1 2 SUBMITTALS A COORDINATION DRAWINGS FOR NATURAL GAS PIPING INCLUDING REQUIRED CLEARANCES AND RELATIONSHIP TO OTHER SERVICES FOR SAME WORK AREAS PART 2 PRODUCTS 2 4 MANUFACTURERS A AVAILABLE MANUFACTURERS SUBJECT TO COMPLIANCE WITH REQUIREMENTS MANUFACTURERS OFFERING PRODUCTS THAT MAY BE INCORPORATED INTO THE WORK INCLUDE BUT ARE NOT LIMITED TO THE FOLLOWING 1 GAS STOPS 2 INCH NPS DN50 AND SMALLER A HAMMOND VALVE CORP B JOMAR INTERNATIONAL LTD C MAXITROL CO D MCDONALD A Y MCDONALD MFQ CO E MILWAUKEE VALVE CO INC F MUELLER CO G NATIONAL METER 2 GAS VALVES 2 INCH NPS DN50 AND SMALLER A CONBRACO INDUSTRIES INC APOLLO DIV B CORE INDUSTRIES INC MUELLER STEAM SPECIALTY DIV C HUBER J M HUBER CORP FLOW CONTROL DIV D MCDONALD A Y MCDONALD MFQ CO E MILLIKEN VALVE CO INC F MILWAUKEE VALVE CO INC G
31. D B INSECT SCREEN ON VENTILATION OPENINGS IESTING FACTORY TESTS A GENERATOR SET FACTORY TESTS ON THE EQUIPMENT TO BE SHIPPED SHALL BE PERFORMED AT RATED LOAD AND RATED PF GENERATOR SETS THAT HAVE NOT BEEN FACTORY TESTED AT RATED PF WILL NOT BE ACCEPTABLE TESTS SHALL INCLUDE RUN AT FULL LOAD MAXIMUM POWER VOLTAGE REGULATION TRANSIENT AND STEADY STATE GOVERNING SINGLE STEP LOAD PICKUP AND SAFETY SHUTDOWNS B TRANSFER EQUIPMENT FACTORY TESTS AUTOMATIC BYPASS TRANSFER SWITCH SHALL BE FACTORY TESTED BEFORE SHIPMENT FACTORY TESTS SHALL INCLUDE A COMPLETE FUNCTIONAL TEST OF THE TRANSFER SWITCH CONTROLS INCLUDING CALIBRATION OF THE VOLTAGE SENSORS FURNISH ALL FACTORY TEST RESULTS OF GENSET AND TRANSFER SWITCH TO THE OWNER FOR HIS RECORDS MINIMUM SIX SETS C THE OWNER S REPRESENTATIVE WILL BE NOTIFIED 2 WEEKS PRIOR TO BEGINNING OF WITNESS TESTING ON SITE ACCEPTANCE TEST A THE COMPLETE INSTALLATION SHALL BE TESTED FOR COMPLIANCE WITH THE SPECIFICATION FOLLOWING COMPLETION OF ALL SITE WORK TESTING SHALL BE CONDUCTED BY QUALIFIED TRAINED REPRESENTATIVE OF THE MANUFACTURER WITH REQUIRED FUEL SUPPLIED BY INSTALLATION CONTRACTOR THE ENGINEER SHALL BE NOTIFIED IN ADVANCE AND TEST TO BE CONDUCTED ON SITE SHALL INCLUDE A COLD START TEST A TWO HOUR FULL LOAD TEST AND A ONE STEP RATED LOAD PICKUP TEST IN ACCORDANCE WITH NFPA 110 PROVIDE A RESISTIVE LOAD BANK AND MAKE TEMPORARY CONNECTIONS FOR FULL LOAD TEST LOAD BANK SHA
32. DEVICES AS INDICATED ON THE DRAWING THE MECHANICAL CONTRACTOR WILL FURNISH ALL CONTROL DEVICES TO THE ELECTRICAL CONTRACTOR AND WILL ASSIST IN THE INSTALLATION OF SAME UNLESS OTHERWISE NOTED CONDUITS ALL CONDUIT SHALL BE CONCEALED IN CONCRETE SLAB IN WALLS OR ABOVE FINISHED CEILINGS UNLESS OTHERWISE NOTED WHERE INDICATED IN SERVICE AREAS EXPOSED CONDUIT SHALL BE INSTALLED TO PROVIDE THE MAXIMUM HEADROOM BUT IN NO CASE SHALL CONDUIT BE INSTALLED LESS THAN SEVEN 7 FEET ABOVE THE FINISHED FLOOR CONDUIT INSTALLED IN AREAS WHERE HUNG CEILINGS OR OTHER FURRED SPACES ARE INDICATED SHALL BE INSTALLED CONCEALED WHERE WORK IS TO BE CONCEALED CARE SHALL BE TAKEN TO INSURE THAT IT DOES NOT PROJECT BEYOND THE FINISHED LINES OF FLOORS CEILINGS OR WALLS EXPOSED CONDUIT AND CONDUIT ABOVE CEILINGS SHALL BE RUN PARALLEL amp PERPENDICULAR TO LINES OF THE BUILDING BENDS SHALL BE FREE FROM DENTS OR FLATTENING CONDUIT SHALL BE SUPPORTED AND SECURELY FASTENED CONDUIT SHALL BE INSTALLED TO MAINTAIN CLEARANCE FROM OTHER PIPING VALVES OR OTHER MECHANICAL EQUIPMENT AND SHALL NOT BE INSTALLED WITHIN 6 OF HOT WATER STEAM PIPING HEATING FLUES OR SIMILAR HOT SURFACES CONDUIT SIZES SHALL BE IN ACCORDANCE WITH THE MINIMUM REQUIREMENTS OF THE NEC EXCEPT NO 1 2 CONDUIT WILL BE PERMITTED ALL CONDUIT IN WALLS FLOORS ABOVE CEILINGS EXPOSED OR UNDERGROUND SHALL BE A MINIMUM OF 93 4 SLEEVES PASSING THROUGH FIRE WALLS AND ALL SLEEVE
33. E WORK INSPECTED FOR CODE COMPLIANCE AND PAY ALL FEES FOR INSPECTION AND CERTIFICATION 47 GUARANTEE ALL WORK IN WRITING TO THE OWNER AGAINST ANY AND ALL DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE YEAR 18 MAINTAIN CONTINUITY OF EXISTING CIRCUITS AFFECTED BY THIS WORK FROM DATE OF ACCEPTANCE AND PERFORM ALL CORRECTIVE WORK AT NO AMPERE GROUND WHICH MUST REMAIN IN SERVICE COST TO THE OWNER ON E LI N E D JAG RAM KEY NOTES ABOVE FINISHED FLOOR INTERRUPTING CAPACITY aasan s di a a hua k ua Ek iaa 2 ABOVE FINISHED GRADE ISOLATED GROUND 19 WHERE ELECTRICAL EQUIPMENT I E PANELBOARDS DISCONNECTS ETC IS 48 A CONTRACTOR MAKING A BID FOR WORK ON THIS PROJECT IS MADE AWARE CONDUIT S INTERLOCKED INDICATED TO BE MODIFIED TO ACCEPT NEW WORK SAID MODIFICATIONS BY THIS NOTE THAT IT IS THE INTENT OF THE OWNER TO HAVE A COMPLETELY O BASIS OF DESIGN PRODUCT NEW EXTERIOR WEATHERPROOF NEMA 3R CIRCUIT BREAKER MECHANICAL CONTRACTOR SHALL BE PERFORMED BY ELECTRICAL EQUIPMENT FABRICATORS OR INSTALLED JOB THE CONTRACTOR MAKING A BID FOR THIS WORK WARRANTS 3 POLE ASCO 3000 SERIES AUTOMATIC TRANSFER SWITCH PROVIDE COUNTER HEIGHT MOTOR OPERATED DAMPER MANUFACTURER S REPRESENTATIVES WHO CAN AFFECT SUCH THAT HE WILL COMPLETE AND WIRE PROVIDING ALL NECESSARY ELECTRICAL LOCKING ENCLOSURE CONDUIT ONLY NOT IN CONTRACT MODIFICATIONS WITHOUT VOIDING THE UL LABEL OR MANUFACTURER S WORK FOR EQUIPMENT SHOWN AND OR DETAILED ON ANY PROJECT WARRANTIES DRAWINGS OR SPECIFIC
34. ED MECHANICS THE ENGINE GENERATOR SET SHALL BE FACTORY FABRICATED AND ASSEMBLED PACKAGE OF NEW AND QUALITY GRADE COMPONENTS ONLY THOSE PRODUCTS CURRENTLY BEING MANUFACTURED FOR THE PURPOSE OF POWER GENERATION WILL BE CONSIDERED ALL WORK SHALL BE OF THE HIGHEST QUALITY PERFORMED BY EXPERIENCED PERSONNEL IN THE FIELD OF POWER GENERATION EQUIPMENT FURNISHED UNDER THIS SECTION SHALL BE GUARANTEED BY THE MANUFACTURER AND ADMINISTERED BY THE SELLING DEALER AGAINST DEFECTS IN MATERIALS OR WORKMANSHIP FOR A PERIOD OF FIVE YEARS FROM DATE OF INITIAL USE IT SHALL COVER FULL PARTS AND LABOR ACCEPTABLE MANUFACTURERS OF STANDBY NATURAL GAS FIRED GENERATORS ARE AS FOLLOWS A KOHLER BASIS OF DESIGN PRODUCT B CUMMINS ONAN C CATERPILLAR SUBMITTALS AND DRAWING REQUIREMENTS COMPLIANCE AT THE TIME OF BID SUPPLIER MUST SUBMIT COMPLIANCE WITH THE SPECIFICATIONS A COPY OF THE MANUFACTURER S PRINTED AND PUBLISHED SERVICE MANUAL PARTS BOOK INSTALLATION GUIDE OPERATION GUIDE SERVICE DIRECTORY AND WARRANTY SHALL BE AVAILABLE TO THE ENGINEER DURING BID EVALUATION SUBMITTAL DATA THE SUCCESSFUL BIDDER SHALL SUBMIT WITHIN ONE 1 WEEK OF ISSUANCE OF PURCHASE ORDER SIX SETS OF BOUND SUBMITTALS INCLUDING BUT NOT LIMITED TO THE FOLLOWING 1 STANDARD MANUFACTURER S PRINTED SPECIFICATION SHEET SHOWING CRITICAL ENGINE AND GENERATOR SET SPECIFICATIONS INCLUDING DIMENSIONS WEIGHTS AND GUARANTEED FUEL CONSUMPTION AT 25 50 75 AND 100 OF FULL R
35. ELECTRICAL GENERAL NOTES 1 DRAWINGS ARE DIAGRAMMATIC AND DEFINE THE INTENT OF THE WORK PULLBOXES SIZE AND TYPE AS REQUIRED O KA680016805 Paha Adminstration BuildingX6805 001 Generator RelocationCADDVDWG56805 001 E001 dwg E 001 LOCATIONS OF EQUIPMENT FIXTURES DEVICES PANELBOARDS DUCTS DRAWING DRAWING LIST PIPING DIFFUSERS PARTITIONS OPENINGS ETC ARE APPROXIMATE AND 29 HEXPOSED RACEWAY IF PERMITTED SHALL BE RUN TRUE PLUMB AND NUMBER ARE SUBJECT TO MODIFICATIONS CAUSED BY STRUCTURAL CONDITIONS AND PARALLEL OR PERPENDICULAR TO BUILDING LINES RIGID METAL CONDUIT EQUIPMENT PROVIDED BY OTHER CONTRACTORS SUBCONTRACTORS OR EMT WITH RAINTIGHT STEEL FITTINGS 3 4 INCH MINIMUM SHALL BE USED T THE OWNER COORDINATE ALL WORK WITH THE WORK OF OTHER TRADES OUTDOORS ELECTRICAL METALLIC TUBING 3 4 INCH MINIMUM SHALL BE ELECTRICAL SYMBOLS NOTES AND ONE LINE DIAGRAM DETERMINE ROUGHING LOCATIONS FROM APPROVED SHOP DRAWINGS USED IN INDOOR UNFINISHED SPACES SURFACE METAL RACEWAY MINOR MODIFICATIONS OF LOCATIONS REQUIRED TO EFFECT SUCH WIREMOLD SHALL BE USED IN INDOOR FINISHED SPACES N A AJ EXISTINGPOLE MOUNTED ELECTRICAL SITE PLAN AND DETAILS COORDINATION SHALL BE MADE AT NO COST TO THE OWNER y yy y N PSE amp G IRANSFORMER 30 ALL WIRING SHALL BE COPPER CONDUCTOR WITH 600 VOLTS INSULATION IN
36. EVIEW AND APPROVAL PROTECT ALL SURFACES FROM PAINT OVERSPRAY DRIPS JOINT CONSTRUCTION A USE MATERIALS SUITABLE FOR NATURAL GAS SERVICE 1 BRAZED JOINTS MAKE JOINTS WITH BRAZING ALLOY HAVING MELTING POINT GREATER THAN 1000 DEG F 540 DEG C BRAZING ALLOYS CONTAINING PHOSPHORUS ARE PROHIBITED VALVE INSTALLATION A INSTALL VALVES IN ACCESSIBLE LOCATIONS PROTECTED FROM DAMAGE TAG VALVES WITH METAL TAG INDICATING PIPING SUPPLIED ATTACH TAG TO VALVE WITH METAL CHAIN B INSTALL GAS VALVE UPSTREAM FROM EACH GAS PRESSURE REGULATOR WHERE 2 GAS PRESSURE REGULATORS ARE INSTALLED IN SERIES VALVE IS NOT REQUIRED AT SECOND REGULATOR C INSTALL PRESSURE RELIEF OR PRESSURE LIMITING DEVICES SO THEY CAN BE READILY OPERATED TO DETERMINE IF VALVE IS FREE TEST TO DETERMINE PRESSURE AT WHICH THEY WILL OPERATE AND EXAMINE FOR LEAKAGE WHEN IN CLOSED POSITION CONNECTIONS A INSTALL GAS PIPING NEXT TO EQUIPMENT AND APPLIANCES USING GAS TO ALLOW SERVICE AND MAINTENANCE B CONNECT GAS PIPING TO EQUIPMENT USING GAS WITH SHUTOFF VALVES AND UNIONS 3 8 LABELS A PROVIDE PREPRINTED NATURAL GAS LABELS EVERY 5 FEET ON ALL EXPOSED PIPING B LABELS SHALL HAVE A YELLOW FIELD WITH BLACK LETTERS 3 9 FIELD QUALITY CONTROL A INSPECT TEST AND PURGE PIPING ACCORDING TO NFPA 54 PART 4 GAS PIPING INSPECTION TESTING AND PURGING AND REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION B REPAIR LEAKS AND DEFECTS WITH NEW MATERIALS AND RETEST S
37. F ACOUSTIC INSULATION AMTERIAL B ACOUSTIC INSULATION THAT MEETS UL 94 HF1 FLAMMABILITY CLASSIFICATION AND REPELS MOISTURE ABSORBTION C SOUND ATTENUATED ENCLOSURE SHALL OFFER AN AVERAGE OF 67 5 db A SOUND LEVEL AT 7 M 23FT USING UP TO 25 mm 1 IN OF ACOUSTIC INSULATION ACOUSTIC LINED AIR INLET HOODS AND ACOUSTIC LINED AIR DISCHARGE HOOD LIFT RINGS A FOUR 4 STEEL LIFT RINGS WELDED AND BOLTED TO UNDERFRAME FOR COMBINED ENCLOSURE EQUIPMENT WEIGHT REMOVAL PANELS A REMOVABLE SERVICE PANELS LOCATED AS REQUIRED BY GENERATOR MANUFACTURER WILL BE PROVIDED FOR EQUIPMENT INSTALLATION AND SERVICE LOUVERS AND OR HOODS A LOUVERS AND OR HOODS WILL BE ALL ALUMINUM CONSTRUCTION RIVETED INTO ALUMINIZED METAL FRAME FORMING A RIGID WATER RESISTANT ASSEMBLY FIXED GRAVITY OR MOTORIZED LOUVERS WILL BE FURNISHED AS SPECIFIED LOUVERS AND HOODS WILL BE PROPERLY SIZED TO ALLOW SUFFICIENT ENGINE COMBUSTION AND RADIATOR AIR FLOW COPYRIGHT 013 FRENCH amp PARRELLO ASSOCIATES PA THE COPYING OR REUSE OF THIS DOCUMENT OR PORTIONS THEREOF WITHOUT THE WRITTEN PERMISSION OF FRENCH amp PARRELLO ASSOCIATES PA IS PROHIBITED DUE TO INHERENT ERRORS IN REPRODUCTION METHODS ERRORS MAY OCCUR WHEN SCALING THIS DRAWING DAMPERS A ELECTRICAL PACKAGE ENCLOSURE SHALL HOUSE SPECIFIC PRE WIRED PER NEC USING CONDUIT amp 600V BUILDING WIRE ELECTRICAL EQUIPMENT AND DEVICES AS SPECIFIED ON DRAWINGS INCLUDING CONVENIENCE OUTLETS AS REQUIRE
38. IMAL DEFLECTION ALTERNATOR THE POWER GENERATOR SHALL BE OF THE SINGLE BEARING TYPE 1800 RPM 80 KW 0 80 PF 60 HZ 3 PHASE 4 WIRE 120 208V PMG TYPE SUBTRANSIENT REACTANCE SHALL BE A MINIMUM OF 0 11 PER UNIT ON THE DIRECT ACCESS THE POWER GENERATOR SHALL BE MANUFACTURED AND PACKAGED BY THE ENGINE MANUFACTURER TO INSURE PROPER PERFORMANCE AND EFFECT A SINGLE SOURCE OF RESPONSIBILITY THE GENERATOR SHALL BE RATED AND CONFORM TO NEMA STANDARDS FOR TEMPERATURE RISE AND CONSTRUCTION THE UNIT SHALL BE SYNCHRONOUS TROPICALIZED AND BUILT PER NEMA MG I 22 AND IEEE STANDARDS CLASS H INSULATION SHALL BE USED ON STATOR AND ROTOR AND BOTH SHALL BE PROTECTED WITH AN ASPHALT MODIFIED EPOXY ON ALL END COILS TEMPERATURE RISE SHALL BE 125 C THE ROTOR ASSEMBLY SHALL DEMONSTRATE 130 OVERSPEED CAPABILITY AT 170 C FOR 2 HOURS THE GENERATOR ROTOR TWO PLANE DYNAMIC BALANCE SHALL BE WITHIN 0 002 PEAK TO PEAK AMPLITUDE DISPLACEMENT WHILE AT OPERATING SPEED THE GENERATOR SHALL HAVE A WAVEFORM DEVIATION OF NOT MORE THAN 5 AND SHALL MEET NEMA LIMITS FOR TELEPHONE INFLUENCE FACTORS GENERATOR PITCH SHALL BE 2 3 POWER SUPPLY TO THE VOLTAGE REGULATOR AND ROTOR FIELD SHALL BE BY A SEPARATE PERMANENT MAGNET GENERATOR PM0 A 24 VOLT DC ELECTRIC STARTING SYSTEM WITH POSITIVE ENGAGEMENT DRIVE SHALL BE FURNISHED INCLUDING THE FOLLOWING A 24 VOLT LEAD ACID STORAGE BATTERIES OF THE HEAVY DUTY NATURAL GAS STARTING TYPE THE BATTERY SET SHALL BE COMPLETE WITH STEE
39. ING COMPLIANCE WITH ALL OF THE REQUIREMENTS OF THIS SPECIFICATION INCLUDING COMPLIANCE WITH THE ABOVE CODES AND STANDARDS AND WITHSTAND AND CLOSING RATINGS THE CERTIFICATION SHALL IDENTIFY BY SERIAL NUMBER S THE EQUIPMENT INVOLVED NO EXCEPTIONS TO THE SPECIFICATIONS OTHER THAN THOSE STIPULATED AT THE TIME OF THE SUBMITTAL SHALL BE INCLUDED IN THE CERTIFICATION F B TERMINALS SHALL BE PROVIDED FOR A REMOTE CONTACT WHICH OPENS TO SIGNAL THE ATS TO TRANSFER TO EMERGENCY AND FOR REMOTE CONTACTS WHICH OPEN TO INHIBIT TRANSFER TO EMERGENCY AND OR RETRANSFER TO NORMAL BOTH OF THESE INHIBIT SIGNALS CAN BE ACTIVATED THROUGH THE KEYPAD OR SERIAL PORT 3 02 VOLTAGE FREQUENCY AND PHASE ROTATION SENSING A VOLTAGE AND FREQUENCY ON BOTH THE NORMAL AND EMERGENCY SOURCES AS NOTED BELOW SHALL BE CONTINUOUSLY MONITORED WITH THE FOLLOWING PICKUP DROPOUT AND TRIP SETTING CAPABILITIES VALUES F C AN INPHASE MONITOR SHALL BE PROVIDED IN THE CONTROLLER THE SHOWN AS OF NOMINAL UNLESS OTHERWISE SPECIFIED MONITOR SHALL CONTROL TRANSFER SO THAT MOTOR LOAD INRUSH SPECIFICATIONS CONTINUED C THE ATS MANUFACTURER SHALL BE CERTIFIED TO ISO 9001 INTERNATIONAL QUALITY STANDARD AND THE MANUFACTURER SHALL HAVE THIRD PARTY HOUSING AUTHORITY CITY OF PERTH AMBOY Corporate Office 1800 Route 34 Suite 101 Ep N Wall NJ 07719 732 312 9800 Regional Offices AMP AMP RevisedBy Checked By CURRENTS DO NOT EXCEED
40. JET DIRECTED AT BOTTOM OF THE PISTONS THE ENGINE SHALL BE EQUIPPED WITH A SPEED CONTROL WITH 0 ISOCHRONOUS SPEED DROOP FROM NO LOAD TO FULL RATED LOAD AND STEADY STATE SPEED REGULATION SHALL BE 0 25 OVER A RANGE OF 40 C TO 75 C THE ENGINE SHALL BE EQUIPPED WITH ANACTUATOR MOUNTED ON THE ENGINE WOODWARD 2301 ELECTRONIC SPEED CONTROL OR EQUAL THE GENERATOR SET SHALL HAVE INSTALLED AND BE WARRANTEED BY THE ENGINE MANUFACTURER WITH THE FOLLOWING ALARMS AND SHUTDOWNS A OIL PRESSURE SHUTDOWN WITH STEP PROTECTION AT HIGH AND LOW IDLE B OVERSPEED SHUTDOWN C OVERCRANK SHUTDOWN D EMERGENCY STOP PUSHBUTTON PROVIDE TWO JACKET WATER HEATERS OF SUFFICIENT CAPACITY TO MAINTAIN JACKET WATER AT 90 F IN AMBIENT TEMPERATURE OF 20 F FOR QUICK EMERGENCY START THEY SHALL BE TANK TYPE TO ENSURE PROPER THERMAL CIRCULATION IMMERSION HEATERS ARE NOT ACCEPTABLE THE HEATERS SHALL BE AS SPECIFIED BY MANUFACTURER EACH AT 120 VOLTS SINGLE PHASE SUPPLIED FROM THE NORMAL POWER SOURCE EACH HEATER SHALL BE THERMOSTATICALLY CONTROLLED WITH ITS OWN THERMOSTAT PROVIDE A CRITICAL GRADE EXHAUST SILENCER MAXIM M41 OR APPROVED EQUAL PROPERLY SIZED AND INSTALLED BY THE MANUFACTURER THE EXHAUST OUTLETS ON THE ENGINE SHALL BE JOINED SO THERE IS ONLY ONE COMMON EXHAUST CONNECTION ONE COMMON FLEXIBLE CONNECTION AND ONE COMPANION FLANGE GASKETS SHALL BE FURNISHED AS REQUIRED PROVIDE A STAINLESS STEEL BELLOWS TYPE FLEXIBLE EXHAUST CONNECTIO
41. L RACK NECESSARY CABLE AND CONNECTORS ALL IN CONFORMANCE WITH THE ENGINE MANUFACTURER S REQUIREMENTS ONE SET OF BATTERIES SHALL BE PROVIDED PER INDIVIDUAL GENERATOR SET BATTERY SET SHALL HAVE SUFFICIENT AMP HOUR CAPACITY FOR ENGINE STARTING ETC WITH AMPLE RESERVE PER MANUFACTURER S RECOMMENDATIONS B A 10 AMP MINIMUM AUTOMATIC DUAL RATE BATTERY CHARGER AS MANUFACTURED BY LAMARCHE OR APPROVED EQUAL SHALL BE PROVIDED THE CHARGER SHALL RECYCLE AUTOMATICALLY TO ON OR HIGH RATE AT SUFFICIENT FREQUENCY TO MAINTAIN HIGH STATE OF CHARGE AND LONG BATTERY LIFE THE CHARGER SHALL BE COMPLETE WITH DC AMMETER VOLTMETER ON OFF SWITCH DC FUSE LOW VOLTAGE ALARM CONTACTS AND CHARQGING INDICATOR LIGHT THE 120 VOLT INPUT TO THE CHARGER SHALL BE AUTOMATICALLY DISCONNECTED DURING ENGINE CR PROVIDE AUTOMATIC TRANSFER SWITCH OF 200 AMPS CAPACITY 3 POLE 600 VOLT FULLY RATED AND MOUNTED IN A NEMA 3R ENCLOSURE IT SHALL INCORPORATE MICROPROCESSOR LOGIC AND CONFORM TO NEMA IC510 1993 NFPA 70 NFPA 99 NFPA 110 AND UL 1008 AND IEEE STANDARD 446 THE SWITCH SHALL BE RATED FOR 208Y 120V SERVICE AND MANUFACTURED BY ASCO RUSSELL ZENITH OR AS APPROVED BY THE ENGINEER AND INCLUDE THE FOLLOWING FEATURES CRANKING CYCLE A THE AUTOMATIC TRANSFER SWITCH SHALL BE THE PRODUCT OF ONE MANUFACTURER AND BE COMPLETELY FACTORY INTERCONNECTED AND TESTED SO THAT ONLY THE SERVICE AND LOAD CONNECTIONS TO THE SWITCH ARE REQUIRED FOR FIELD INSTALLATION
42. LER STEEL PIPE MALLEABLE IRON THREADED FITTINGS AND THREADED JOINTS Corporate Office 1800 Route 34 Suite 101 Ep N Wall NJ 07719 732 312 9800 Regional Offices FRENCFISPARRELLO Hackettstown NJ No Revision Revised By Checked By AMIN H GOMAA PE DRAWN BY CHECKED BY PROFESSIONAL ENGINEER NJ LIC No 24GE04842100 AMP AHG 3 2 3 3 3 4 3 5 3 6 2 1 1 4 TO 2 INCH NPS DN32 TO DN50 STEEL PIPE MALLEABLE IRON THREADED FITTINGS AND THREADED JOINTS 3 1 1 4 TO 2 INCH NPS DN32 TO DN50 STEEL PIPE BUTT WELDING FITTINGS AND WELDED JOINTS 4 2 1 2 TO 4 INCH NPS DN65 TO DN100 STEEL PIPE MALLEABLE IRON THREADED FITTINGS AND THREADED JOINTS C MEDIUM PRESSURE 0 5 TO 2 PSIG 3 45 TO 13 8 KPA NATURAL GAS SYSTEMS USE THE FOLLOWING 1 1 INCH NPS DN25 AND SMALLER STEEL PIPE BUTT WELDING FITTINGS AND WELDED JOINTS 2 1 1 4 INCH NPS DN32 AND LARGER STEEL PIPE BUTT WELDING FITTINGS AND WELDED JOINTS D HIGH PRESSURE ABOVE 2 TO 5 PSIG 13 8 TO 34 5 KPA NATURAL GAS SYSTEMS STEEL PIPE BUTT WELDING FITTINGS AND WELDED JOINTS E UNDERGROUND NATURAL GAS SYSTEMS USE PE PIPE COMPLYING WITH ASTM D 2513 SDR 11 INLET CONNECTED TO STEEL PIPE COMPLYING WITH ASTM A 53 A 53M SCHEDULE 40 TYPE E OR S GRADE B WITH CORROSION PROTECTIVE COATING FOR ABOVE GROUND OUTLET 1 A YELLOW INSULATED COPPER TRACER WIRE SHALL BE INSTALLED ADJACENT TO UNDERGROUND NONMET
43. LL BE ADJUSTABLE TO ACCOMMODATE ACTUAL BUILDING LOAD IF REQUIRED LOAD BANK PROVIDED BY MANUFACTURER AND WIRED BY INSTALLATION CONTRACTOR B COMPLETELY TEST AND CHECK OUT ALL FLUID LEVELS AND FILTERS GENERATOR CONTROLS ENGINE HEATER BATTERY CHARGER AND AUTOMATIG TRANSFER SWITCH FUNCTIONS IN BOTH NORMAL AND EMERGENCY POSITIONS CHECK FOR EXHAUST AND FUEL LEAKS EXCESSIVE VIBRATION AND PHASE ROTATION MAKE THE FOLLOWING ADJUSTMENTS AND SETTINGS GENERATOR SPEED AND ALL AUTOMATIC TRANSFER SWITCH RELAYS AND TIMERS TO THE SATISFACTION OF THE OWNER FOR PROPER STANDBY POWER SYSTEM OPERATIONS TEST RESULTS SHALL INCLUDE ENGINE TEMPERATURE OIL PRESSURE BATTERY CHARGE LEVEL AND FREQUENT INTERVALS THROUGHOUT THE TESTS FURNISH ALL TEST RESULTS TO THE OWNER FOR RECORDS C MANUFACTURER S FIELD REPRESENTATIVE SHALL ARRANGE FOR ONE 1 DAY OF ON SITE TRAINING FOR OWNER PERSONNEL IN THE OPERATION OF THE SYSTEM THE TIME AND DATE FOR THIS TRAINING PERIOD SHALL BE COORDINATED WITH THE OWNER 1 6 25 15 ADDENDA NO 1 No Date Revision AMP AMP RevisedBy Checked By Corporate Office 1800 Route 34 Suite 101 Ep N Wall NJ 07719 732 312 9800 Regional Offices FRENCGH amp PARRELLO Hackettstown NJ New York NY AMIN H GOMAA PE PROFESSIONAL ENGINEER NJ LIC No 24GE04842100 SPECIFICATIONS CONTINUED HOUSING AUTHORITY CITY OF PERTH AMBOY STANDYBY GENERATOR INSTALLATION 881 AMBOY AVENUE
44. MENTS PAD SHALL EXTEND 12 BEYOND THE FOOTPRINT OF THE GENERATOR ENCLOSURE PIPE SIZING BASED ON IFGC 2009 TABLE 402 4 1 LONGEST RUN 17 LF INCLUDES 20 FITTING ALLOWANCE GAS RISER DIAGRAM NOT TO SCALE QGENERATOR PAD DETAIL NOT TO SCALE NOTE THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK RELATING TO GENERATORS INCLUDING ALL GAS PIPING AND CONNECTIONS SERVICE ON ENTRANCE NEW ON TIME DELAY RELAY EQUIPMENT PROVIDE ONE 1 RELAY PER HVAC UNIT TO CONTROL CIRCUIT EXISTING HVAC CONTROL CIRCUIT EXISTING NORMAL HVAC UNIT EMERG amp 3 POLE TRANSFER WITCH s LEGEND BJ BONDING JUMPER EGC EQUIPMENT GROUNDING CONDUCTOR G GROUND BLOCK GEC GROUNDING ELECTRODE CONDUCTOR Fuss n GNC GROUNDED NEUTRAL CONDUCTOR i d 5 TYPICAL LOAD SHED RELAY DETAIL NOT TO SCALE NOTES 2 1 DETAIL IS TYPICAL AND IS INTENDED TO ILLUSTRATE METHODS OF GROUNDING AND BONDING OF ELECTRICAL x x 4 PRECAST DISTRIBUTION SYSTEM COMPONENTS STONE CAP 2 BONDING JUMPERS BJ GROUNDING ELECTRODE CONDUCTORS GEC GROUNDED NEUTRAL CONDUCTORS GNC AND HI EQUIPMENT GROUNDING CONDUCTORS EGC SHALL ALL BE INSULATED BONDING JUMPERS BJ MAY BE BARE WHEN a l S ITE PLAN WITHIN AN ENCLOSURE OR LESS THAN 6 0 IN LENGTH INSULATION COLORS SHALL BE AS FOLLOWS PD EA BJ GREEN 2 NOT TO SCALE GEC GREEN HORIZ REINF 16
45. N A 90 ELBOW WITH RAINCAP WILL ALSO BE INSTALLED ON THE MUFFLER OUTLET EXHAUST WILL TRAVEL THROUGH THE ENCLOSURE AND EXHAUST AT THE ROOF LEVEL GENERATOR MAIN OUTPUT CIRCUIT BREAKER SHALL BE UL LISTED MOLDED CASE THERMAL MAQGNETIC TYPE AND SHALL BE MOUNTED ON THE GENERATOR IT SHALL BE SIZED AT 200A WITH 3 POLE 208 VOLTS WITH A 24 VOLT DC SHUNT TRIP THE VOLTAGE REGULATOR SHALL BE SOLID STATE THREE SENSING VOLTS PER HERTZ TYPE AND MANUFACTURED BY THE ENGINE GENERATOR SET MANUFACTURER IT SHALL BE SHOCK MOUNTED IN THE GENERATOR PROVIDING 1 NO LOAD TO FULL LOAD REGULATION VOLTAGE DRIFT SHALL BE NO MORE THAN 0 5 OF RATED VALUE AT CONSTANT TEMPERATURE ADJUSTABLE CONTROLS FOR VOLTAGE DROOP LEVEL AND GAIN SHALL BE EASILY ACCESSIBLE VOLTAGE LEVEL ADJUSTMENT SHALL BE A MINIMUM 10 CURRENT LIMITING CIRCUITS SHALL BE USED TO RESTRAIN EXCITER FIELD CURRENT IN THE EVENT OF A SUSTAINED LOW POWER FACTOR LOAD IT SHALL PROVIDE RAPID RESPONSE DURING TRANSIENT CONDITIONS OVERVOLTAGE AND UNDERVOLTAQGE PROTECTION SHALL BE PROVIDED ALONG WITH A SOLID STATE CIRCUIT TO REMOVE EXCITATION WHEN GENERATOR OVERLOAD FOR MORE THAN 10 SECONDS OCCURS TELEPHONE INFLUENCE FACTOR SHALL NOT EXCEED 50 AT FULL THROTTLE ENGINE STARTING OUTPUT VOLTAGE SHALL NOT OVERSHOOT MORE THAN 5 OF ITS RATED VALUE WITH RESPECT TO THE VOLTS HZ CURVE AND RESPONSE TIME SHALL BE LESS THAN 20 MILLISECONDS A GENERATOR MOUNTED NFPA 110 SOLID STATE PRE WIRED CONTROL PANEL WITH DIGITAL
46. NICAL INSPECTION AND ELECTRICAL TEST LISTED MANUAL MOTOR STARTER WITH THERMAL OVERLOADS ALL PERTINENT CATALOG NUMBERS OPTIONS ETC HIGHLIGHTED OR TARGETED LOOSE SHEETS OR BINDING SYSTEMS RELYING ON PAPER CLIPS 44 PROVIDE TWO SETS OF OPERATION AND MAINTENANCE MANUALS BOUND OR SLIP ON SPLINES WILL BE DISCARDED AND THE TRANSMITTAL RETURNED AND INDEXED WITH INSTRUCTIONS FOR ALL ELECTRICAL DEVICES PUSH BUTTON TO THE CONTRACTOR EQUIPMENT APPLIANCES AND SYSTEMS 16 ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE CURRENT EDITION IN 45 PROVIDE ONE SET OF REPRODUCIBLE CONTRACT DRAWINGS OR DIGITAL EFFECT OF THE NATIONAL ELECTRICAL CODE NEC NATIONAL ELECTRICAL DATA FILES USING SAME SOFTWARE PROGRAM VERSION AND OPERATING EMERGENCY PUSH BUTTON SAFETY CODE NESC AMERICAN ELECTRICIANS HANDBOOK NEW JERSEY SYSTEM AS CONTRACT DOCUMENTS THAT HAVE BEEN REVISED AND fN UNIFORM FIRE CODE NJUFC NEW JERSEY UNIFORM CONSTRUCTION CODE ANNOTATED TO REFLECT THE AS BUILT CONDITIONS OF THE PROJECT NJUCO INTERNATIONAL BUILDING CODE IBC ACCESSIBLE amp USABLE BUILDINGS amp FACILITIES ICC ANSI A117 1 AND NATIONAL ELECTRICAL 46 DELIVER CERTIFICATES OF ELECTRICAL AND OTHER INSPECTIONS OR COPIES ELECTRIC ONE LINE DIAGRAM CONTRACTORS ASSOCIATION NECA STANDARD OF INSTALLATION THEREOF TO THE OWNER AT THE COMPLETION OF THE PROJECT WITH FPQ e N s v O Qc T COPIES TO THE ENGINEER NOT TO SCALE 17 OBTAIN ALL PERMITS REQUIRED HAVE TH
47. OR CONTROL WIRING STRANDED CONDUCTOR POWER DEVICE LEGEND MAKE USE OF ALL DATA IN ALL OF THE CONTRACT DOCUMENTS AND VERIFY INFORMATION AT THE PROJECT SITE 34 TAPS AND SPLICES FOR BRANCH CIRCUITS AND FEEDERS LARGER THAN 10 PESGBIBSISN AWG SHALL BE MADE WITH BURNDY INSUL TAP TYPE BIPC OR APPROVED 5 THE OWNER WILL OCCUPY THE SITE AND EXISTING BUILDING DURING THE EQUAL INSULATION PIERCING CONNECTORS OR BURNDY HYLUG OR ENTIRE CONSTRUCTION PERIOD COOPERATE WITH THE OWNER DURING APPROVED EQUAL COMPRESSION SPLICES SURFACE MOUNTED PANELBOARD POWER AND LIGHTING CONSTRUCTION OPERATIONS TO AVOID ANY CONFLICTS PERFORM THE L WORK SO AS NOT TO INTERFERE WITH THE OWNER S OPERATIONS 35 TAPS AND SPLICES FOR BRANCH CIRCUITS AND FEEDERS 10 AWG AND e s sj SCHEDULE ALL POWER OUTAGES FOR OVERTIME ON SUNDAYS AND HOLIDAYS SMALLER SHALL BE MADE WITH IDEAL MODELS 410 411 AND 412 CRIMP _ EXISTING AT NO ADDITIONAL COST TO THE OWNER CONNECTORS OR APPROVED EQUAL WITH MODELS 415 OR 417 INSULATED _EXTERIOR RECESSED PANELBOARD POWER AND LIGHTING CAPS PANELBOARD 6 EXISTING PROJECT CONDITIONS INDICATED ARE BASED ON FIELD l 400A MDB OBSERVATION AND ARE INTENDED TO INDICATE THE SCOPE OF THE WORK 36 BRANCH CIRCUIT AND FEEDER TAPS SHALL BE FULL CIRCUIT SIZE UP TO sSQUARED AFFECTED BY THIS PROJECT THEIR OVERCURRENT PROTECTION DEVICE I LINE HOMERUN TO PANELBOARD 7 THE TERM OTHERS SHALL BE UNDERSTOOD TO MEAN CONTRACTORS 37 STRANDED WIRING COND
48. OR EXCEED THE REQUIREMENTS FOR 2 PRIOR TO AND AFTER TRANSFER 4 DATA AND TIME ENGINE STOPPED E IPOM G EU ONP HP s ros 3 NORMAL TO EMERGENCY ONLY 5 DATA AND TIME EMERGENCY SOURCE AVAILABLE 1 EN 55011 1991 EMISSION STANDARD GROUP 1 CLASS A 4 EMERGENCY TO NORMAL ONLY 6 DATA AND TIME EMERGENCY SOURCE NOT AVAILABLE 2 EN 50082 2 1995 GENERIC IMMUNITY STANDARD FROM WHICH 5 NORMAL TO EMERGENCY AND EMERGENCY TO NORMAL 1 192 CCI SDI Dr s SDD r 6 _ALL TRANSEER CONDITIONS OR ONLY WHEN BOTH SOURCES ARE AVAILABLE STATISTICAL DATA ENV 50140 1993 EN 61000 4 4 1995 EN 61000 4 5 1995 RADIATED ELECTRO MAGNETIC FIELD IMMUNITY ELECTRICAL FAST TRANSIENT EFT IMMUNITY F NOT USED s LeTOTAENUMBEP OP IeNSr Erno SURGE TRANSIENT IMMUNITY G NOT USED 2 TOTAL NUMBER OF TRANSFERS DUE TO SOURCE FAILURE EN 61000 4 6 1996 CONDUCTED RADIO FREQUENCY FIELD IMMUNITY 3 TOTAL NUMBER OF DAYS CONTROLLER IS ENERGIZED 3 IEEE472 ANSI C37 90A RING WAVE TEST 304 ADDITIONAL FEATURES 4 TOTAL NUMBER OF HOURS BOTH NORMAL AND EMERGENCY SOURCES ARE AVAILABLE 2 03 ENCLOSURE A A THREE POSITION MOMENTARY TYPE TEST SWITCH SHALL BE PROVIDED FOR THE TEST AUTOMATIC RESET MODES THE TEST POSITION WILL SIMULATE A NORMAL SOURCE FAILURE THE RESET POSITION SHALL BYPASS THE TIME DELAYS ON EITHER TRANSFER TO EMERGENCY OR RETRANSFER TO NORMAL F J COMMUNICATIONS MODULE A FULL DUPLEX RS485 INTERFACE SHALL BE INSTALLED IN THE ATS CONTROLLER TO ENABLE
49. P AND RESET SETTINGS FOR EACH SOURCE A A FOUR LINE 20 CHARACTER LCD DISPLAY AND KEYPAD SHALL BE AN INTEGRAL PART OF THE CONTROLLER FOR VIEWING ALL AVAILABLE DATA AND SETTING DESIRED OPERATIONAL PARAMETERS OPERATIONAL PARAMETERS SHALL ALSO BE AVAILABLE FOR VIEWING AND LIMITED CONTROL THROUGH THE SERIAL COMMUNICATIONS INPUT PORT THE FOLLOWING PARAMETERS SHALL ONLY BE ADJUSTABLE VIA DIP SWITCHES ON THE CONTROLLER 402 TESTSAND CERTIFICATION F THE FOLLOWING FEATURES SHALL BE BUILT IN TO THE CONTROLLER BUT CAPABLE OF BEING ACTIVATED THROUGH KEYPAD PROGRAMMING OR THE 1 NOMINAL LINE VOLTAGE AND FREQUENCY SERIAL PORT ONLY WHEN REQUIRED BY THE USER 2 SINGLE OR THREE PHASE SENSING A THE COMPLETE ATS SHALL BE FACTORY TESTED TO ENSURE PROPER OPERATION OF THE INDIVIDUAL COMPONENTS AND CORRECT OVERALL SEQUENCE OF OPERATION AND TO ENSURE THAT THE OPERATING TRANSFER TIME VOLTAGE FREQUENCY AND TIME DELAY SETTINGS ARE IN COMPLIANCE WITH THE SPECIFICATION REQUIREMENTS F A PROVIDE THE ABILITY TO SELECT COMMIT NO COMMIT TO TRANSFER TO DETERMINE WHETHER THE LOAD SHOULD BE TRANSFERRED TO THE EMERGENCY GENERATOR IF THE NORMAL SOURCE RESTORES BEFORE THE GENERATOR IS READY TO ACCEPT THE LOAD 4 TRANSFER OPERATING MODE CONFIGURATION OPEN TRANSITION SIRUCTIO ACCESSIBLE READABLE AND ACCOMPLISHED WITHOUT THE USE OF CODES CALCULATIONS OR INSTRUCTION MANUALS B UPON REQUEST THE MANUFACTURER SHALL PROVIDE A NOTARIZED LETTER CERTIFY
50. ROM 0 TO 60 MINUTES TIME DELAY SHALL BE AUTOMATICALLY BYPASSED IF THE EMERGENCY SOURCE FAILS AND THE NORMAL SOURCE IS ACCEPTABLE F D THE CONTROLLER SHALL BE CAPABLE OF ACCEPTING A NORMALLY OPEN CONTACT THAT WILL ALLOW THE TRANSFER SWITCH TO FUNCTION IN A NON AUTOMATIC MODE USING AN EXTERNAL CONTROL DEVICE F E ENGINE EXERCISER THE CONTROLLER SHALL PROVIDE AN INTERNAL ENGINE EXERCISER THE ENGINE EXERCISER SHALL ALLOW THE USER TO PROGRAM UP TO SEVEN DIFFERENT EXERCISE ROUTINES FOR EACH ROUTINE THE USER SHALL BE ABLE TO F E A ENABLE OR DISABLE THE ROUTINE F E B ENABLE OR DISABLE TRANSFER OF THE LOAD DURING ROUTINE F E C SET THE START TIME TIME OF DAY DAY OF WEEK WEEK OF MONTH 1ST 2ND 3RD 4TH ALTERNATE OR EVERY F A SET THE DURATION OF THE RUN F A AT THE END OF THE SPECIFIED DURATION THE SWITCH SHALL TRANSFER THE LOAD BACK TO NORMAL AND RUN THE GENERATOR FOR THE SPECIFIED COOL DOWN PERIOD A 10 YEAR LIFE BATTERY THAT SUPPLIES POWER TO THE REAL TIME CLOCK IN THE EVENT OF A POWER LOSS WILL MAINTAIN ALL TIME AND DATE INFORMATION F B SYSTEM STATUS THE CONTROLLER LCD DISPLAY SHALL INCLUDE A SYSTEM STATUS SCREEN WHICH SHALL BE READILY ACCESSIBLE FROM ANY POINT IN THE MENU BY DEPRESSING THE ESC KEY A MAXIMUM OF TWO TIMES THIS SCREEN SHALL DISPLAY A CLEAR DESCRIPTION OF THE ACTIVE OPERATING SEQUENCE AND SWITCH POSITION FOR EXAMPLE NORMAL FAILED LOAD ON NORMAL TD NORMAL TO EMERG 2MIN15S F
51. ROOFTOP UNIT RTU 1 EXISTING SQUARE D TYPE NQOD E2 SERIES PANELBOARD EXISTING MCB SHORT CIRCUIT RATING 10KA RMS SYM AMPS 2 BOLT ON BREAKERS ONLY 3 CONTRACTOR IS RESPONSIBLE TO COORDINATE THE SHORT CIRCUIT RATING PRIOR TO PURCHASING ANY EQUIPMENT 4 ALL WIRE SIZES ARE BASED ON 75 DEGREE WIRE ADDENDA NO 1 SPACE Corporate Office 1800 Route 34 Suite 101 Wall NJ 07719 732 312 9800 Regional Offices FRENCGH amp PARRELLO Hackettstown NJ New York NY ELECTRICAL PANEL SCHEDULES HOUSING AUTHORITY CITY OF PERTH AMBOY STANDYBY GENERATOR INSTALLATION 881 AMBOY AVENUE PERTH AMBOY NJ 08862 PERTH AMBOY O KAV680016805 Paha Adminstration BuildingX6805 001 Generator RelocationCADDVNDWG516805 001 E200 dwg E 200 te Revision AMP AMP RevisedBy Checked By MONMOUTH COUNTY NEW JERSEY SCALE PROJECT NUMBER 6805 001 DATE DESIGNED BY 06 03 2015 AMP AS NOTED AMIN H GOMAA PE DRAWN BY CHECKED BY FIELD BOOK SHEET PROFESSIONAL ENGINEER NJ LIC No 24GE04842100 AMP AHG E 200 COPYRIGHT 013 FRENCH amp PARRELLO ASSOCIATES PA THE COPYING OR REUSE OF THIS DOCUMENT OR PORTIONS THEREOF WITHOUT THE WRITTEN PERMISSION OF FRENCH amp PARRELLO ASSOCIATES PA IS PROHIBITED DUE TO INHERENT ERRORS IN REPRODUCTION METHODS ERRORS MAY OCCUR WHEN SCALING THIS DRAWING O KAV680016805 Paha Adminstration BuildingX6805 001 Generator Relocation
52. RY CHARGER SEE PANEL SCHEDULE FOR 1 SYMBOLS ARE INDICATED FOR GENERAL REFERENCE ONLY THE PREMISES IF REQUESTED BY THE OWNER ALL DEVICES RACEWAY WIRING BRANCH CIRCUIT WIRING PRESENCE OF A SYMBOL DOES NOT INDICATE ITS USE ON THIS PROJECT CABLE SUPPORTING DEVICES ETC REMOVED OR ABANDONED AS A RESULT OF THIS WORK MAKE SAFE ALL I D ns A 501 MUST x CONTRACTOR SHALL COORDINATE SERVICE SHUTDOWN WITH PSE amp G AT 7 j 5 Pv APPLICABLE CODES LEAST 4 WEEKS IN ADVANCE CONTACT PSE amp G CONSTRUCTION rP yJ AS TN SERVICES AT 800 782 0067 TO MAKE ALL REQUIRED ARRANGEMENTS 24 REMOVE AND RELOCATE EXISTING EQUIPMENT FIXTURES DEVICES ETC AS 1 THE NATIONAL ELECTRICAL CODE NEC 2011 INDICATED AND AS REQUIRED TO CLEAR NEW WORK EXTEND AND CONNECT 2 INTERNATIONAL BUILDING CODE IBC 2009 NJ EDITION NEW WIRING TO EXISTING 3 NATIONAL ELECTRICAL SAFETY CODE NESC 4 NEW JERSEY UNIFORM FIRE CODE NJUFC 25 REMOVE AND REINSTALL CEILING SYSTEM AS REQUIRED FOR THE 5 NEW JERSEY UNIFORM CONSTRUCTION CODE NJUCC INSTALLATION OF ELECTRICAL WORK AND REPLAGCE IN KIND ANY 6 ACCESSIBLE amp USABLE BUILDINGS amp FACILITIES ICC ANSI A117 1 COMPONENTS DAMAGED BY PERSONNEL OR EQUIPMENT DURING 7 NATIONAL ELECTRICAL CONTRACTORS ASSOCIATION NECA STANDARD OF PERFORMANCE OF THE WORK COORDINATE WITH ARCHITECT INSTALLATION 26 PERFORM ALL CUTTING AND PATCHING REQUIRED FOR THE INSTALLATION OF THE WORK CUT NO STRUCTURAL MEMBER WITHOUT WRITTEN PERMISSION
53. S PASSING THROUGH FLOORS SHALL BE SIZED TO ALLOW SUFFICIENT SPACE BETWEEN SLEEVE AND CONDUIT FOR FIREPROOFING WITH 3M FIRE BARRIER CAULKING MATERIAL CP25 ALL SPARE SLEEVES PASSING THROUGH FIRE WALLS OR FLOORS SHALL BE THOROUGHLY PACKED WITH 3M FIRE BARRIER PUTTY 303 AND CAPPED FLEXIBLE LIQUID TIGHT CONDUIT SHALL BE PROVIDED TO CONNECT TO ALL MOTORS DELICATE INSTRUMENTS AND CONTROLS AND TO VIBRATING EQUIPMENT INSTALLATION SHALL BE SUCH SO AS TO SUPPORT CONDUIT WITHOUT SAGGING AND SHALL BE CLEAR OF THE WORK OF OTHER TRADES PROVISIONS FOR EXPANSION AND CONTRACTION SHALL BE MADE CONDUITS SHALL BE FREE OF MOISTURE AND MANHOLES SHALL BE DRY CONDUIT WORK IN AREAS WHERE NO HUNG CEILINGS ARE PROVIDED SHALL BE RUN EXPOSED UNLESS SPECIFICALLY NOTED OTHERWISE IN EXPOSED AND HUNG CEILINGS ALL LIGHTING RECEPTACLE AND SWITCH BRANCH CIRCUITS SHALL BE RUN IN EMT A SIX FOOT WHIP OF MC FLEXIBLE CONDUIT SHALL BE CONNECTED TO LIGHTING FIXTURES IN STUD WALLS VERTICAL DROPS SHALL BE MC FLEXIBLE CONDUIT IN FINISHED OR UNFINISHED BLOCK WALLS VERTICAL DROPS SHALL BE EMT CONDUIT RUN IN THE WALL BOXES PULL BOXES SHALL BE OF AMPLE SIZE FOR THE APPLICATION AND SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE NEC REQUIREMENTS PULL BOXES SHALL BE INSTALLED BETWEEN A MAXIMUM OF EVERY 3 RIGHT ANGLE BENDS OR THE EQUIVALENT LONG CONDUITS RUNS SHALL HAVE A PULL BOX AT LEAST EVERY 100 0 ALL PULL BOXES SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS
54. SEN OF ELIZABETHTOWN GAS 908 662 8361 CONNECT NEW 2 GAS PIPING TO EXISTING GAS PIPING FIELD VERIFY EXACT LOCATION AND SIZE OF EXISTING PIPING CONTRACTOR SHALL TAKE PRESSURE READING FROM EXISTING GAS PRESSURE TO PROPERLY SELECT REGULATOR SPRING RATES REGULATOR SHALL BE MAXITROL SERIES RV OR EQUAL J 3 C O 1 EXISTING PANEL P 2 EXISTING PANEL L 4 EXISTING SERVICE DISCONNECT SWITCH C T CABINET AND PSE amp G METER SEE ONE LINE DIAGRAM ON DRAWING E 001 FOR CONDUIT AND FEEDER INFORMATION CONTRACTOR SHALL CAREFULLY COORDINATE ALL UNDERGROUND PIPING AND CONDUIT WITH ALL TRADES AND THE UTILITY COMPANIES CONTACT UTILITY COMPANIES AND OBTAIN MARK OUT PRIOR TO COMMENCING ANY WORK I s 2 11 e sen nas 2 l l CZ us FURNISH AND INSTALL TIME DELAY RELAYS AND CABINET FOR s _ I MECHANICAL EQUIPMENT LOAD SHED RELAYS FIELD COORDINATE EXACT LOCATION OF ALL EQUIPMENT IN THE FIELD FIELD COORDINATE EXACT ROUTING OF CONTROL WIRING TO ATS i CONTRACTOR SHALL RUN CONCEALED IN ALL LOCATIONS CONDUIT l ROUTED ABOVE SUSPENDED ACOUSTICAL TILE CEILINGS OR IN ATTIC WHERE EVER POSSIBLE CUT AND PATCH EXISTING GYP BOARD i m as CEILINGS AND WALLS AS REQUIRED AND PAINT TO MATCH EXISTING 2 1 ru Is FINISH g O ia s i p CMU AND ORNAMENTAL FENCE GENERATOR SURROUND REFER TO DETAIL ON DRAWING E 100 FOR ADDITIONAL INFORMATION
55. SERIAL COMMUNICATIONS THE SERIAL COMMUNICATIONS SHALL BE CAPABLE OF A DIRECT CONNECT OR MULTI DROP CONFIGURED NETWORK THIS MODULE SHALL ALLOW FOR THE SEAMLESS INTEGRATION OF EXISTING OR NEW COMMUNICATION TRANSFER DEVICES THE SERIAL COMMUNICATION INTERFACE SHALL BE EQUAL TO ASCO ACCESSORY 72A F K EXTERNAL DC POWER SUPPLY AN OPTIONAL PROVISION SHALL BE AVAILABLE TO CONNECT AN EXTERNAL 24 VDC POWER SUPPLY TO ALLOW THE LCD AND THE DOOR MOUNTED CONTROL INDICATORS TO REMAIN FUNCTIONAL WHEN BOTH POWER SOURCES ARE DEAD THIS OPTION SHALL BE EQUIVALENT TO ASCO ACCESSORY 1G A THE ATS SHALL BE FURNISHED IN A TYPE 3R ENCLOSURE UNLESS OTHERWISE SHOWN ON THE PLANS B ALL STANDARD AND OPTIONAL DOOR MOUNTED SWITCHES AND PILOT LIGHTS SHALL BE 16 MM INDUSTRIAL GRADE TYPE OR EQUIVALENT FOR EASY VIEWING amp REPLACEMENT DOOR CONTROLS SHALL BE PROVIDED ON A SEPARATE REMOVABLE PLATE WHICH CAN BE SUPPLIED LOOSE FOR OPEN TYPE UNITS B A SPDT CONTACT RATED 5 AMPS AT 30 VDC SHALL BE PROVIDED FOR A LOW VOLTAGE ENGINE START SIGNAL THE START SIGNAL SHALL PREVENT DRY CRANKING OF THE ENGINE BY REQUIRING THE GENERATOR SET TO REACH PROPER OUTPUT AND RUN FOR THE DURATION OF THE COOL DOWN SETTING REGARDLESS OF WHETHER THE NORMAL SOURCE RESTORES C A PRESSURE DISCONNECT LINK SHALL BE PROVIDED TO DISCONNECT THE PEFORE THE LOADISTRANSFERRED NORMAL SOURCE NEUTRAL CONNECTION FROM THE EMERGENCY AND LOAD NEUTRAL CONNECTIONS FOR 4 MM WIRE APPLICATIONS A GROUND BUS
56. SERIES OR APPROVED EQUAL PART 2 PRODUCTS 201 MICROPROCESSOR CONTROLLER A THE CONTROLLER S SENSING AND LOGIC SHALL BE PROVIDED BY A SINGLE BUILT IN MICROPROCESSOR FOR MAXIMUM RELIABILITY MINIMUM MAINTENANCE AND THE ABILITY TO COMMUNICATE SERIALLY THROUGH AN OPTIONAL SERIAL COMMUNICATION MODULE B A SINGLE CONTROLLER SHALL PROVIDE TWELVE SELECTABLE NOMINAL VOLTAGES FOR MAXIMUM APPLICATION FLEXIBILITY AND MINIMAL SPARE PART REQUIREMENTS VOLTAGE SENSING SHALL BE TRUE RMS TYPE AND SHALL BE ACCURATE TO 1 OF NOMINAL VOLTAGE FREQUENCY SENSING SHALL BE ACCURATE TO 0 2 THE PANEL SHALL BE CAPABLE OF OPERATING OVER A TEMPERATURE RANGE OF 20 TO 60 DEGREES C AND STORAGE FROM 55 TO 85 DEGREES C C THE CONTROLLER SHALL BE CONNECTED TO THE TRANSFER SWITCH BY AN INTERCONNECTING WIRING HARNESS THE HARNESS SHALL INCLUDE A KEYED C D E REPETITIVE ACCURACY OF ALL SETTINGS SHALL BE WITHIN 0 5 OVER AN OPERATING TEMPERATURE RANGE OF 20C TO 60C VOLTAGE AND FREQUENCY SETTINGS SHALL BE FIELD ADJUSTABLE IN 1 INCREMENTS EITHER LOCALLY WITH THE DISPLAY AND KEYPAD OR REMOTELY VIA SERIAL COMMUNICATIONS PORT ACCESS THE CONTROLLER SHALL BE CAPABLE WHEN ACTIVATED BY THE KEYPAD OR THROUGH THE SERIAL PORT OF SENSING THE PHASE ROTATION OF BOTH THE NORMAL AND EMERGENCY SOURCES THE SOURCE SHALL BE CONSIDERED UNACCEPTABLE IF THE PHASE ROTATION IS NOT THE PREFERRED ROTATION SELECTED ABC OR CBA SOURCE STATUS SCREENS SHALL BE PROVIDED
57. SHALL BE PROVIDED FOR CONNECTION OF THE GROUNDING CONDUCTOR TO THE GROUNDING ELECTRODE A PRESSURE DISCONNECT LINK FOR THE THE NORMAL SOURCE AND ONE CONTACT CLOSED WHEN THE ATS IS NEUTRAL TO GROUND BONDING JUMPER SHALL BE PROVIDED TO CONNECT CONNECTED TO THE EMERGENCY SOURCE THE NORMAL NEUTRAL CONNECTION TO THE GROUND BUS 4 01 WITHSTAND AND CLOSING RATINGS C AUXILIARY CONTACTS RATED 10 AMPS 250 VAC SHALL BE PROVIDED CONSISTING OF ONE CONTACT CLOSED WHEN THE ATS IS CONNECTED TO PART 4 ADDITIONAL REQUIREMENTS D LED INDICATING LIGHTS 16 MM INDUSTRIAL GRADE TYPE 12 SHALL BE PROVIDED ONE TO INDICATE WHEN THE ATS IS CONNECTED TO THE NORMAL SOURCE GREEN AND ONE TO INDICATE WHEN THE ATS IS CONNECTED TO THE EMERGENCY SOURCE RED PART 3 OPERATIONS A THE ATS SHALL BE RATED TO CLOSE ON AND WITHSTAND THE AVAILABLE RMS SYMMETRICAL SHORT CIRCUIT CURRENT AT THE ATS TERMINALS 3 01 CONTROLLER DISPLAY AND KEYPAD B THE ATS SHALL BE UL LISTED IN ACCORDANCE WITH UL 1008 AND BE LABELED IN ACCORDANCE WITH THAT STANDARD S 1 2 AND 3 CYCLE LONG TIME RATINGS ATS s WHICH ARE NOT TESTED AND LABELED WITH 11 AND 3 CYCLE ANY BREAKER RATINGS AND HAVE SERIES OR SPECIFIC BREAKER RATINGS ONLY ARE NOT ACCEPTABLE E LED INDICATING LIGHTS 16 MM INDUSTRIAL GRADE TYPE 12 SHALL BE PROVIDED AND ENERGIZED BY CONTROLLER OUTPUTS THE LIGHTS SHALL PROVIDE TRUE SOURCE AVAILABILITY OF THE NORMAL AND EMERGENCY SOURCES AS DETERMINED BY THE VOLTAGE SENSING TRI
58. UCTORS SHALL BE MADE UP TO SCREW TERMINALS usa SUBCONTRACTORS OR TRADESMEN ON THE PROJECT PERFORMING WORK WITH 3M T amp B OR PANDUIT LOCKING FORK CRIMP TERMINALS WITH NYLON NEW GENERATOR ON THIS PROJECT UNDER SECTIONS OR DIVISIONS OTHER THAN DIVISION 16 INSULATED GRIPS 80 KW 120 208V 3 PHASE LT peas SUNG TIONDOSS WALMOUNTED ELECTRICAL WORK KOHLER NATURAL GAS 38 CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION AND INSTALLATION IN E MA SE ENG SUNE 8 VERIFY THAT FIELD MEASUREMENTS ARE AS INDICATED DETAILS AND VERIFY ALL MANUFACTURER S REQUESTS PRIOR TO ANY JUNCTION BOX CEILING MOUNTED SUBMISSION FOR CONSIDERATION BY ENGINEER OR OWNER 9 PRIOR TO BIDDING VISIT THE PROJECT SITE TO DETERMINE THE CONDITIONS UNDER WHICH THE WORK IS TO BE DONE SCHEDULE SITE VISITWITHOWNER 39 DO NOT INSTALL EXPOSED WIRING OR CABLE NOT UL LISTED FOR THE POWER FEED TO SYSTEM FURNITURE WALL MOUNTED PROVIDE PURPOSE WOOD SUPPORTS OR ANCHORAGES NONMETALLIC CONDUIT FLEXIBLE WHIP CONNECTION TO THE FURNITURE AS REQUIRED 10 PROVIDE ALL LABOR MATERIALS AND EQUIPMENT REQUIRED FOR THE BOXES OR FITTINGS OR VINYL PLASTIC NYLON OR OTHER COMBUSTIBLE OR 152 n nn n INSTALLATION RELOCATION AND CONNECTION OF THE ELECTRICAL WORK SMOKE PRODUCING IDENTIFICATION OR CONSTRUCTION MATERIALS IN THE 1 SPACE ABOVE HUNG CEILINGS USED AS A PLENUM FOR THE RETURN OF 11 ALL MATERIAL SHALL BE UNDERWRITERS LABORATORIES LISTED FOR ITS ENVIRONMENTAL AIR
59. WHETHER OR NOT THESE CONNECTIONS ARE SHOWN ON THE DRAWINGS THE GROUNDING INSTALLATION SHALL HAVE PROVISIONS FOR BOTH SYSTEM AND EQUIPMENT GROUNDS AS DEFINED BY THE NEC THESE GROUNDING SYSTEMS ARE TO BE EFFECTIVELY INSULATED FROM EACH OTHER EXCEPT AT THE SERVICE CONNECTION GROUNDING SHALL BE DONE IN ACCORDANCE WITH THE PROVISIONS OF NEC AND THE NESC LOCAL REQUIREMENTS OF THE INSPECTION AUTHORITY HAVING JURISDICTION SHALL GOVERN IN ALL MATTERS OF INTERPRETATION SAFETY SWITCHES FURNISH AND INSTALL ALL DISCONNECT SWITCHES INDICATED ON THE DRAWINGS UNLESS OTHERWISE NOTED ALL SAFETY SWITCHES SHALL BE QUICK MAKE QUICK BREAK TYPE ALL SAFETY SWITCHES STARTERS PUSH BUTTONS AND ENCLOSURES SHALL BE UL LISTED AND SHALL BE NEMA 1 FOR INDOOR AND NEMA 3R FOR OUTDOOR UNLESS OTHERWISE NOTED ALL SAFETY SWITCHES SHALL BE HORSEPOWER RATED AND HAVE PROVISIONS FOR LOCKOUT ALL SAFETY SWITCHES SHALL BE AS MANUFACTURED BY SQUARE D CUTLER HAMMER OR APPROVED EQUAL 9 EXISTING UTILITIES THE LOCATION OF ALL EXISTING UTILITIES SHOWN ON THIS SET OF PLANS HAS BEEN DETERMINED FROM FIELD MEASUREMENTS AND OR PLANS PROVIDED TO FRENCH amp PARRELLO ASSOCIATES NO GUARANTEE IS MADE NOR SHOULD BE ASSUMED AS TO THE COMPLETENESS OR ACCURACY OF THE HORIZONTAL OR VERTICAL LOCATIONS ALL PARTIES UTILIZING THIS INFORMATION SHALL FIELD VERIFY THE ACCURACY AND COMPLETENESS OF THE INFORMATION SHOWN PRIOR TO CONSTRUCTION ACTIVITIES COPYRIGHT 013 FREN
60. WITHOUT THE WRITTEN PERMISSION OF FRENCH amp PARRELLO ASSOCIATES PA IS PROHIBITED DUE TO INHERENT ERRORS IN REPRODUCTION METHODS ERRORS MAY OCCUR WHEN SCALING THIS DRAWING O 6KA680016805 Paha Adminstration BuildingX6805 001 Generator RelocationCADD_IDWCG516805 001 E100 dwg E 100 COORDINATE WITH GENERATOR FOR SIZE PATCH TO MATCH EXISTING COMPACTED SOIL CHAMFER ALL EXPOSED EDGES TYPICAL MAGNETIC WARNING TAPE 8 MIN CONC SLAB 2 CLEAN SAND FILL 4 4 2 CLEAR z 4 GENERATOR SCHEDULE 40 PVC s N CONDUIT AND 1 SCHEDULE 40 PVC N POWER AND CONTROL CONDUITS REFER TO ONE LINE DIAGRAM AND zeae EaGNAWaq SCHEDULES FOR FEEDER SIZES AND z NOTES NOT TO SCALE 1 GENERAL ALL MATERIALS SHALL BE IN CONFORMITY WITH ACI BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE LATEST EDITION BEES bESSEEUEATISB GAS COCK UNION PORTLAND CEMENT APPROVED BRAND ASTM SPECIFICATIONS C 150 TYPE I TO BE 3500 PSI AT 28 DAYS REINFORCING BARS TO BE ASTM A 615 COARSE AGGREGATE HARD DURABLE CLEAN UNCOATED CRUSHED STONE OR GRAVEL ASTM SPECIFICATIONS C 33 SAND CLEAN HARD DURABLE UNCOATED GRAINS FREE FROM SILT LOAM CLAY OR OTHER DELETERIOUS SUBSTANCES ASTM SPECIFICATION C 33 M WATER CLEAN AND FREE FROM DELETERIOUS SUBSTANCES GENERATOR 1185 CFH GRADE 2 PAD DIMENSIONS SHALL BE SIZED ACCORDING TO GENERATOR MANUFACTURER S REQUIRE
61. XISTING 20 0 0 0 0 EXISTING EXISTING VAV BOXES 20 EXISTING RECEPTACLES 6 RECEPTACLES 8 10 FURNACE ACC 2 30 EXISTING EXISTING RECEPTACLES 12 EXISTING RECEPTACLES 14 KITCHEN RECEPTACLES 20 EXISTING EXISTING LIGHTING 16 KITCHEN RECEPTACLES 20 EXISTING EXISTING RECEPTACLES 18 KITCHEN RECEPTACLES 20 EXISTING EXISTING RECEPTACLES 20 KITCHEN LIGHTING 20 EXISTING EXISTING RECEPTACLES 22 ALARM 20 EXISTING EXISTING BATHROOM 24 EXISTING LOAD 20 EXISTING EXISTING OFFICE LIGHTING 26 SITE LIGHTING 20 EXISTING EXISTING ENTRY LIGHTING 28 EXISTING RECEPTACLES 30 REFRIGERATOR 20 EXISTING EXISTING RECEPTACLES 32 ELECTRIC STOVE 40 EXISTING EXISTING CANOPY LIGHTING 34 EXISTING LIGHTING 36 PANEL TYPE NEMA 1 MOUNTING SURFACE MAIN CIRCUIT BREAKER 200A I SrEX STING KA SYM D ID 1L LA 1 EXISTINGCUTLER HAMMER TYPE PB PANELBOARD 2 BOLT ON BREAKERS ONLY TOTAL PHASE 3 CONTRACTOR IS RESPONSIBLE TO COORDINATE THE SHORT CIRCUIT RATING PRIOR TO PURCHASING ANY EQUIPMENT 4 ALL WIRE SIZES ARE BASED ON 75 DEGREE WIRE 5 FIELD VERIFY BREAKER SIZE JOB NAME PERTH AMBOY GENERATOR RATING 208 120V 4W 3PH 225A CKT CIRCUIT NO DESCRIPTION POLE LOAD B BRANCH KVA CIRCUIT
62. YSTEM UNTIL SATISFACTORY RESULTS ARE OBTAINED C REPORT TEST RESULTS PROMPTLY AND IN WRITING TO ARCHITECT AND AUTHORITIES HAVING JURISDICTION D VERIFY CAPACITIES AND PRESSURE RATINGS OF GAS METERS REGULATORS VALVES AND SPECIALTIES E VERIFY CORRECT PRESSURE SETTINGS FOR PRESSURE REGULATORS F VERIFY THAT SPECIFIED PIPING TESTS ARE COMPLETE 40 ADJUSTING A ADJUST CONTROLS AND SAFETY DEVICES REPLACE DAMAGED AND MALFUNCTIONING CONTROLS AND SAFETY DEVICES SPECIFICATIONS HOUSING AUTHORITY CITY OF PERTH AMBOY New York NY 881 AMBOY AVENUE PERTH AMBOY NJ 08862 PERTH AMBOY MONMOUTH COUNTY NEW JERSEY DATE DESIGNED BY SCALE 06 03 2015 AMP AS NOTED STANDYBY GENERATOR INSTALLATION PROJECT NUMBER sos eman FIELD BOOK SHEET se O 6KA680016805 Paha Adminstration BuildingX6805 001 Generator RelocationCADDVDWG56805 001 E300 dwg E 301 GENERATOR SPECIFICATIONS FURNISH ALL EQUIPMENT MATERIALS AND LABOR TO INSURE A COMPLETE FUNCTIONAL AND RELIABLE STANDBY NATURAL GAS FIRED POWER UNIT AS SPECIFIED HEREIN ONLY MANUFACTURER S AUTHORIZED DEALERS WHO HAVE A MINIMUM OF FIFTEEN YEARS EXPERIENCE IN THE FIELD OF POWER GENERATION WITH THE SAME MANUFACTURER WHOSE PRODUCTS ARE BEING OFFERED AND CAN CERTIFY TO THIS REQUIREMENT ARE ALLOWED TO SUPPLY EQUIPMENT FOR THIS PROJECT THE DEALER MUST BE AUTHORIZED BY THE MANUFACTURER TO ADMINISTRATE WARRANTY FOR THE ENGINE GENERATOR SET AND MUST EMPLOY FACTORY TRAIN
63. n BuildingX6805 001 Generator RelocationCADDVNDWG516805 001 E300 dwg E 302 DISCONNECT PLUG TO ENABLE THE CONTROLLER TO BE DISCONNECTED FROM THE TRANSFER SWITCH FOR ROUTINE MAINTENANCE SENSING AND CONTROL LOGIC SHALL BE PROVIDED ON MULTI LAYER PRINTED CIRCUIT BOARDS INTERFACING RELAYS SHALL BE INDUSTRIAL GRADE PLUG IN TYPE WITH DUST COVERS THE PANEL SHALL BE ENCLOSED WITH A PROTECTIVE COVER AND BE MOUNTED SEPARATELY FROM THE TRANSFER SWITCH UNIT FOR SAFETY AND EASE OF MAINTENANCE THE PROTECTIVE COVER SHALL INCLUDE A BUILT IN POCKET FOR STORAGE OF THE OPERATOR S MANUALS PARAMETERS F F DATA LOGGING THE CONTROLLER SHALL HAVE THE ABILITY TO LOG DATA AND TO MAINTAIN THE LAST 99 EVENTS EVEN IN THE EVENT OF TOTAL POWER LOSS THE FOLLOWING EVENTS SHALL BE TIME AND DATE STAMPED AND MAINTAINED IN A NON VOLATILE MEMORY D A TIME DELAY SHALL BE PROVIDED ON SHUT DOWN OF ENGINE GENERATOR FOR COOL DOWN ADJUSTABLE FROM 0 TO 60 MINUTES E A TIME DELAY ACTIVATED OUTPUT SIGNAL SHALL ALSO BE PROVIDED TO DRIVE AN EXTERNAL RELAY S FOR SELECTIVE LOAD DISCONNECT CONTROL THE CONTROLLER SHALL HAVE THE ABILITY TO ACTIVATE AN ADJUUSTABIE 0 TO 5 EVENT LOGGING MINUTE TIME DELAY IN ANY OF THE FOLLOWING MODES 1 DATA AND TIME AND REASON FOR TRANSFER NORMAL TO EMERGENCY O i O O 2 ir 5 2 DATA AND TIME AND REASON FOR TRANSFER EMERGENCY TO NORMAL 1 PRIOR TO TRANSFER ONLY 3 DATA AND TIME AND REASON FOR ENGINE START E THE CONTROLLER SHALL MEET