1. Equivalent WARNING Please read completely before you install or operate your new pump This is an external out of pond pump It is NOT submersible Do NOT allow this pump to become submerged Never run dry Max case pressure 65 PSI tt EF tt OF EE ars EEO Poran PO O OA parapa A O Made in the USA Tse inw ecostream We congratulate you on your choice of the Teton ecostream Centrifugal Pump It has been carefully designed using the advantages of today s technology and carefully constructed to give you the dependability of yesterday To insure proper performance we urge you to carefully follow the instructions in this manual If you have any questions call Teton Dynamics for assistance INSTALLATION Please read carefully When properly installed the Teton ecostream will provide dependable trouble free service 1 Locate the pump as near the water source as possible A flooded suction situation is preferred The pump is not self priming therefore if the fluid level is below the pump a swing check valve must be installed and the pump primed prior to start up Figure 2 2 Mount motor base to a secure immobile foundation 3 Use only plastic fittings on both the intake and discharge ports Seal pipe connections with Teflon paste These fittings should be self supported and in neutral alignment with each port i e Fittings must not be forced into alignment which may cause premature line
2. E T 3 BN ecostream MAINTENANCE Lubrication Motor Permanently Lubricated ball bearings no service required Rotary Seal Requires no lubrication after assembly The pump must be drained before servicing or if stored below freezing temperatures Periodic replacement of seals may be required due to normal carbon wear Symptom Problem Resolution Pri t ith water and purge all air from suction piping Insufficient Prime Mai eiia pug piping Install check valve Verify power supply and connection from panel to pump Insufficient Power k yP PPY P pump Verify proper voltage Some models are dual voltage 115 230 Ensure valves are open No Flow 3 ne Ensure plumbing is clear including suction strainers check valves etc Flow Restriction Verify check valve orientation and direction of permitted flow Clean out leaves or other debris from basket strainer if applicable Air leak Fix air leaks at fittings connections strainer basket etc This typically occurs on the intake side System Incompatibility Verify hydraulic compatibility i e pump amp pipe are sized for the system Air leak Fix air leaks at fittings connections strainer basket etc This typically occurs on the intake side System Incompatibility Verify hydraulic compatibility i e pump amp pipe are sized for the system Verify power supply and connection from panel to pump Insufficien
3. O RING BRACKET aO AY amp O amp WASHER XT4000LH DRAIN PLUG amp O RING pY WASHER amp LOCK NUT XT3200 XT4400 s A I Ja j XT5000 XT6000 Bolt di O Sd ee Za P XT7000 XT8000 Xf amp O RING DISASSEMBLY R WASHER 1 Shut off power to motor before disconnecting any electrical wiring from the back of the motor 2 Disassemble volute from bracket by removing the screws 3 Remove cap covering shaft at back of motor and with a large screwdriver prevent shaft rotation while unscrewing impeller 4 Remove ceramic piece from impeller If you are replacing the seal 5 Detach bracket from motor 6 Remove carbon graphite seal from bracket by pressing out from the back Do not dig out from the front If you are replacing the seal
4. dual voltage 115 230 Ensure valves are open Flow Restriction Ensure plumbing is clear including suction strainers check valves etc Verify check valve orientation and direction of permitted flow Teton Dynamics Limited Warranty This product is warranted to the initial purchaser to be free of defects in materials and workmanship at the time of initial purchase and for a period of 2 years for Teton ecostream products In the event this product malfunctions within two years from the date of purchase the sole obligation of Teton Dynamics hereinafter referred to as Teton Dynamics will be to repair the unit or replace with an equivalent new or factory refurbished unit at Teton Dynam ics discretion subject to the following conditions 1 The malfunction is proved attributable to a defect in materials or workmanship including repairs performed under this warranty Malfunction for any other reason including but not limited to misuse negligence accident or tampering with parts incorrect wiring or improper installation will not be remedied under this warranty 2 Teton Dynamics specifically does not guarantee chemical compatibility and expressly does not warrant units from any problems caused by chemical attack or failure due to incompatibility of fluid being pumped with pump materials of construction Purchaser shall also retain and present to Teton Dynamics evidence of purchaser s compatibil
5. ay not apply to you No action shall be brought for breach of any implied or express warranty after one year subsequent to the expiration of the duration period of the express written warranty 7 Incidental and consequential damages caused by malfunction defect or otherwise and with respect to breach of any express or implied warranty are not the responsibility of Teton Dynamics and to the extent permitted by law are hereby excluded both for property damage and to the extent not unconscionable for personal injury damage Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you 8 This warranty does not apply to any malfunction arising out of any application of this product other than normal use unless such application is upon request specifically approved in writing by Teton Dynamics 9 The provisions of this warranty are severable and if any provision shall be deemed invalid the remaining provi sions shall remain in full force and effect 10 Rights under this warranty are not assignable without the express prior consent in writing by Teton Dynamics and regardless of the terms of such consent in writing such assignee shall have no greater rights than his assignor had against Teton Dynamics 11 After the warranty period units requiring maintenance or repair may qualify for our exchange program The exchange program provides an oppor
6. failure or damage to the pump volute For non flooded installations a strainer basket and check valve are recommended 4 Never restrict the intake Keep both input and discharge lines as free of elbows and valves as possible Always use pipe of adequate diameter This will reduce friction losses and maximize output 5 The Teton ecostream is not self priming It must not be run dry We recommend a flooded suction installation Please read carefully When properly installed the Teton ecostream will provide dependable trouble free service ABOVE GROUND FLOODED SUCTION BASKET STRAINER Figure 2 WARNING DO NOT RUN DRY WARNING ALWAYS SHUT OFF ELECTRICAL POWER BEFORE INSTALLATION AND OR SERVICING THIS AN PUMP All electrical wiring should meet state and local ordinances Improper wiring may not only be a safety hazard but may permanently damage the motor and or pump 230V 50 HZ MOTORS AVAILABLE CONTACT YOUR SUPPLIER FOR INFORMATION ELECTRICAL HOOK UP 1 Check that supply voltages match the motor s requirements 2 Check motor wiring and connect according to instructions on motor to match supply voltage 3 Power cord should be protected by conduit or by cable and be of proper gauge It should be no longer than necessary 4 Power should be drawn directly from a box with circuit breaker protection or with a fused disconnect switch Ton ecostream PUMP END ASSEMBLY 1 Clean and inspect all pump parts
7. ity tests under actual operating conditions 3 All warranty repairs must be performed by Teton Dynamics or a Teton Dynamics authorized company Purchaser must retain the purchase receipt and present it with this certificate as proof of ownership and entitle ment to warranty repairs Unauthorized repairs will not be compensated by Teton Dynamics and are not the responsibility of Teton Dynamics and if such repairs damage the product such damages are not remedied under this warranty Address i City State Zip Model _ Serial Number YEAR WARRANTY Date purchased Where purchased _ Activate your warranty by filling out this form and mailing to Teton Dynamics 4 Purchaser shall bear all shipping packing and insurance costs and all other costs excluding labor and parts necessary to effectuate repairs under this warranty 5 Periodic check ups are not covered by this warranty 6 This warranty is in lieu of all other express warranties which now or hereafter might otherwise arise with respect to this product Any and all limited warranties including the warranties of merchantability and fitness for particular purpose shall have no greater duration than the duration period of the express written warranty applicable to this product and shall terminate automatically the expiration of such duration period Some states do not allow limitations on how long an implied warranty lasts so the above limitation m
8. o ring seal seats motor shaft etc 2 Apply sealant to the bracket bore ID wall and around the seal case follow sealant mfg instructions We recommend using Gasgacinch Silicone sealant can also be used Press carbon graphite seal into bracket while taking care not to damage carbon graphite face Place slinger rubber washer over motor shaft and mount bracket to motor Carefully lubricate the seal seat elastomer OD and impeller hub ID with water Press the seal seat into the impeller hub making certain that the ceramic is in evenly the sealing surface should be parallel with the impeller hub Carefully lubricate carbon graphite and ceramic sealing surfaces with CLEAN water Do not use silicon lubricants or grease 7 Assemble Bracket to motor with four M bolts 8 Thread impeller onto shaft and tighten If required remove motor end cap and use a screwdriver on the back of motor shaft to prevent shaft rotation while tightening Replace motor end cap 9 Seat large O ring in volute slot and assemble volute to bracket with screws washers and nuts Tighten in a cross pattern 30 in lbf 10 Install drain plug with its O ring in volute drain hole 11 Before operating pump allow a proper cure time for the sealant used in step 2 ul BR W O BRACKET SLINGER IMPELLER IMPELLER WASHER on RY WS BRACKET SLINGER FLANGED LOCK NUT ES D WASHER amp LOCK NUT g lt D A IMPELLER DRAIN PLUG amp
9. t Power cE iia p r Verify proper voltage Some models are dual voltage 115 230 Ensure valves are open Flow Restriction Ensure plumbing is clear including suction strainers check valves etc Low Flow Clean out leaves or other debris from basket strainer if applicable Insufficient Prime Prime system with water and purge all air from suction piping Verify airtight plumbing on the suction plumbing especially fittings Clean out leaves or other debris from basket strainer if applicable Cavitation Increase pipe size where possible Decrease suction pipe length reduce the number of elbows etc Verify hydraulic compatibility i e pump and pipe are sized for the system Insufficient Power Verify power supply and connection from panel to pump Sporadic Operation Verify proper voltage Some models are dual voltage 115 230 Poor Ventilation Ensure adequate airflow over motor to prevent overheating Verify airtight plumbing on the suction plumbing especially fittings Clean out leaves or other debris from basket strainer if applicable Cavitation Increase pipe size where possible Decrease suction pipe length reduce the number of elbows etc Excessive Noise Verify hydraulic compatibility i e pump and pipe are sized for the system Insufficient Power Verify power supply and connection from panel to pump Verify proper voltage Some models are
10. tunity to repair replace your pump and or motor at a nominal charge Please refer to the Exchange Policy or contact Teton Dynamics for details and current pricing Teton Dynamics PO Box 1044 San Leandro CA 94577 Ph 800 752 0399 Fax 510 317 9101 info tetondynamics com Teton ecostream is a registered trademark of Teton Dynamics Gasgacinch is a registered trademark of Porter Manufacturing Teflon is a registered trademark of DuPont Company All rights reserved 2012 Teton Dynamics Te nms ecostream M INSTALLATION AND SERVICE MANUAL Please fill in for future reference MODEL SERIAL NUMBER DATE PURCHASED XT4000LH XT3200 XT4400 XT5000 XT7000 XT8000 MAX FLOW gph 4200 3300 4500 5100 6100 7200 8220 MAX HEAD feet 12 21 21 22 23 22 6 22 MAX POWER watts 166 215 253 293 344 452 541 MAX CURRENT amps 1 5 115V 1 9 115V 2 2 115V 2 6 115V 3 0 115V 7 3 115V 7 7 115V VOLTS 115V 115 230V 115 230V 115 230V 115 230V 115 230V 115 230V MOTOR HP 1 8 1 8 1 6 1 4 1 3 1 2 1 2 MOTOR Enclosed Enclosed Enclosed Enclosed Enclosed Enclosed Enclosed INLET 2 FPT 1 1 2 FPT 1 1 2 FPT 1 1 2 FPT 1 1 2 FPT 2 FPT 2 FPT 2 SOC 2 SOC 2 SOC 2 SOC 2 SOC 2 SOC 2 SOC DISCHARGE 1 1 2 FPT 1 1 2 FPT 1 1 2 FPT 1 1 2 FPT 1 1 2 FPT 2 FPT 2 FPT 2 SOC 2 SOC 2 SOC 2 SOC 2 SOC 2 SOC 2 SOC