FUJITSU Server PRIMERGY CX2550 M1 Server Node
Contents
1. Do not touch the circuitry on boards or soldered parts Hold the metallic areas or the edges of the circuit boards 24 Operating Manual CX2550 M1 Important information CAUTION e Install the screw removed during installation detaching Internal Options in former device position To use a screw of the different kind causes a breakdown of equipment e The installation indicated on this note is sometimes changed to the kind of possible options without notice Batteries CAUTION e Incorrect replacement of batteries may lead to a risk of explosion The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer refer to the FUJITSU Server PRIMERGY CX2550 M1 Server Node Upgrade and Maintenance Manual e Do not throw batteries into the trash can e Batteries must be disposed of in accordance with local regulations concerning special waste e Replace the lithium battery on the system board in accordance with the instructions in the FUJITSU Server PRIMERGY CX2550 M1 Server Node Upgrade and Maintenance Manual e All batteries containing pollutants are marked with a symbol a crossed out garbage can In addition the marking is provided with the chemical symbol of the heavy metal decisive for the classification as a pollutant Cd Cadmium Hg Mercury Pb Lead CX2550 M1 Operating Manual 25 Important information Working with CDs DVDs BDs and optical drives When working
2. ServerView Suite Quick Start Guide Safety Notes and Regulations manual 2 amp 0 Citi for the Japanese market Warranty manual Ri for the Japanese market Returning used devices manual and Service Desk leaflet H zR h 8 4 E A for the Japanese market FUJITSU Server PRIMERGY CX2550 M1 Server Node Upgrade and Maintenance Manual D3343 BIOS Setup Utility for FUJITSU Server PRIMERGY CX2550 M1 Server Node Reference Manual Further information The PRIMERGY CX2550 M1 Server Node is a multi node system For information on the server enclosure please refer to the following manuals Quick Start Hardware PRIMERGY CX400 M1 Server Node FUJITSU Server PRIMERGY CX400 M1 Server Enclosure Operating Manual FUJITSU Server PRIMERGY CX400 M1 Server Enclosure Upgrade and Maintenance manual All documentation on PRIMERGY hardware and ServerView software is available online from the Fujitsu manuals server at For the global market http manuals ts fujitsu com For the Japanese market http jp fujitsu com platform server primergy manual The complete PRIMERGY documentation set can also be downloaded as a DVD ISO image at For the global market fip fip ts fujitsu com images serverview manuals For the Japanese market http jp fujitsu com primergy downloads 8 Operating Manual CX2550 M1 Introduction i For the Japanese market Before using the
3. Advanced Thermal Design the ambient temperature can increase to 40 C If the unit is integrated into an installation that draws power from an industrial power supply network with an IEC309 connector the power supply s fuse protection must comply with the requirements for non industrial power supply networks for type A connectors The unit automatically adjusts itself to a mains voltage in a range of 100 240 V Ensure that the local mains voltage lies within these limits This device must only be connected to properly grounded power outlets or insulated sockets of the rack s internal power supply with tested and approved power cords Ensure that the device is connected to a properly grounded power outlet close to the device 22 Operating Manual CX2550 M1 Important information CAUTION Ensure that the power sockets on the device and the properly grounded power outlets are freely accessible The On Off button or the main power switch if present does not isolate the device from the mains power supply To disconnect it completely from the mains power supply unplug all network power plugs from the properly grounded power outlets Always connect the server node and the attached peripherals to the same power circuit Otherwise you run the risk of losing data if for example the server node is still running but a peripheral device e g memory subsystem fails during a power outage Data cables must be adequately s
4. ServerView Suite Installation Manager user s guide on the Fujitsu manuals server under x86 Servers Software ServerView Suite Server Installation and Deployment Configuration information can also be found in section Operating system installation on page 47 Local configuration and installation with or without the ServerView Installation Manager see section Configuring the server node on page 46 or locally in the ServerView Suite Installation Manager user s guide i You will find more information on installing the server node remotely on the Fujitsu manuals server under x86 Servers Software ServerView Suite Server Installation and Deployment 20 Operating Manual CX2550 M1 4 Important information In this chapter you will find essential information regarding safety when working on your server node 4 1 Safety instructions The following safety instructions are also provided in the manual Safety Notes and Regulations or Z EOD CFE This device meets the relevant safety regulations for IT equipment If you have any questions about whether you can install the server node in the intended environment please contact your sales outlet or our customer service team CAUTION e The actions described in this manual shall be performed by technical specialists A technical specialist is a person who is trained to install the server including hardware and software e Repairs to the device tha
5. activated after the restart The indicator also lights up in standby mode You can find more details on the indicated errors in the System Event Log SEL in the ServerView Operations Manager or via the IRMC S4 s Web interface ID ID indicator blue Lights up blue when the system has been selected by pressing on the ID button in the chassis frontpanel The ID indicator can also be activated via the iIRMC S4 Web interface and its status reported to the IRMC S4 40 Operating Manual CX2550 M1 Starting up and operation CSS indicator orange Lights up orange if a prefailure event was detected for a CSS component that you can fix yourself for reasons of precaution with the CSS concept Flashes orange if an error was detected that you can fix yourself with the CSS concept Does not light up when the supervised components are OK If the event is still acute after a power cycle the indicator is activated after the restart The indicator also lights up in standby mode CX2550 M1 Operating Manual 41 Starting up and operation 6 1 1 3 LAN indicators Figure 4 LAN indicators No Indicator Description 1 ILAN Steady green signal when a LAN connection exists i ewapste7 Remains dark when no LAN connection exists Flashes green when LAN transfer takes place 2 LAN speed Steady orange signal in the event of a LAN transfer rate of 1 Gbit s Steady green signal in the
6. use of an AC uninterruptible power supply is recommended This notice follows the guidelines of Voltage Dip Immunity of Personal Computer issued by JEITA the Japan Electronics and Information Technology Industries Association Technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents produced by Fujitsu may contain technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents which contain such technology should not be exported from Japan or transferred to non residents of Japan without first obtaining authorization in accordance with the above law Harmonic Current Standards This product conforms to harmonic current standard JIS C 61000 3 2 Only for the Japanese market About SATA hard disk drives The SATA version of this server supports hard disk drives with SATA BC SATA storage interfaces Please note that the usage and operation conditions differ depending on the type of hard disk drive used Please refer to the following internet address for further information on the usage and operation conditions of each available type of hard disk drive http jp fujitsu com platform server primergy harddisk Operating Manual CX2550 M1 Contents 1 i troducho s erene FRR EE GSS Eee Oe eS 7 1 1 Concept and target groups for this manual 7 1 2 Documentation overview aaao eee ees 8 1 3 Notational conventions LL aaa aaa 9 2 Fun
7. Fujitsu manuals server under x86 Servers Expansion Cards Storage Adapters LSI SAS SCSI RAID Controllers Further information on other SAS SATA RAID controllers e g for operating external SAS SATA hard disk drives or tape drives is available on the Fujitsu manuals server under x86 Servers Expansion Cards Storage Adapters LSI SAS SCSI RAID Controllers USB connectors The two USB 3 0 connectors of the server node support activities carried out by the service technician The maximum length of the external cable are three meters High level of availability and data security When memory data is accessed 1 bit errors are identified in the main memory and automatically corrected with the error correcting code ECC method A RAID controller supports different RAID levels and increase the availability and data security of the system The hot plug HDD modules provide additional availability iRMC S4 with integrated management LAN connector The iRMC S4 integrated Remote Management Controller is a Baseboard Management Controller BMC with integrated management LAN connector and expanded functionality that was previously only available with additional plug in cards In this way the IRMC S4 enables complete control of PRIMERGY servers regardless of system status and thus particularly the control of PRIMERGY servers that are in the out of band system status Major functions supported by the iRMC S4 include the followi
8. SCSI is a protocol for linking servers and data storage facilities similar to the Fibre Channel Protocol FCP iSCSI means SCSI over Internet Protocol iSCSI boot allows a server to be booted remotely from a drive in an iSCSI based Storage Area Network SAN For further instructions please refer to the iSCSI Boot for PRIMERGY Servers with Intel Network Controllers installation and configuration guide on the Fujitsu manuals server under x86 Servers Expansion Cards Network Controllers Intel Network Controllers CX2550 M1 Operating Manual 47 Starting up and operation 6 4 Cleaning the server node CAUTION Switch the server node off and disconnect the power plugs from the properly grounded power outlets Do not clean any interior parts yourself leave this job to a service technician Do not use any cleaning agents that contain abrasives or may corrode plastic Ensure that no liquid enters the system Ensure that the ventilation areas of the server node and the monitor are clear Do not use any cleaning sprays including flammable types It may cause a device failure or a fire Clean the keyboard and the mouse with a disinfecting cloth Wipe the server node and monitor casing with a dry cloth If particularly dirty use a cloth that has been moistened in a mild domestic detergent and then carefully wrung out 48 Operating Manual CX2550 M1 7 Property and data protection To protect the in
9. by the logo on the identification rating plate 4 CAUTION In a system that has the Cool safe Advanced Thermal Design Option only components that support the higher operating range my be installed Further information on this is available in the configurator Operating Manual CX2550 M1 Functional overview 2 2 Server node specification This section explains the specifications for the server node The specifications for this server node are liable to be updated without any notice Please be forewarned System Board System board type D3343 Chipset Intel C610 Processor Processor quantity and type 2 x Intel Xeon processor E5 2600v3 product family Memory Modules Configuration Memory slots 16 4 channels per CPU with 8 DIMMs per CPU 16 DIMM in total Memory slot type DDR4 Memory capacity min max 16 GB 1024 GB Memory protection Advanced ECC SDDC Chipkill Memory notes Supports LV R DIMM LV LR DIMM Interfaces USB connectors 2 x USB 3 0 Graphics 15 pin 1x VGA LAN Ethernet RJ 45 2 x Gbit s Ethernet 1 x 100Mbit Management LAN onboard Management LAN RJ45 Management LAN traffic can be switched to shared onboard Gbit LAN port CX2550 M1 Operating Manual Functional overview Onboard or integrated controllers LAN controller Intel Ethernet C
10. contact with the disk surface 26 Operating Manual CX2550 M1 Important information e Donot contaminate the CD DVD BD surface with fingerprints oil dust etc If dirty clean with a soft dry cloth wiping from the center to the edge Do not use benzene thinners water record sprays antistatic agents or silicone impregnated cloth e Be careful not to damage the CD DVD BD surface e Keep the CDs DVDs BDs away from heat sources e Do not bend or place heavy objects on CDs DVDs BDs e Do not write with ballpoint pen or pencil on the label printed side e Donotattach stickers or similar to the label side Doing so may cause rotational eccentricity and abnormal vibrations e When a CD DVD BD is moved from a cold place to a warm place moisture condensation on the CD DVD BD surface can cause data read errors In this case wipe the CD DVD BD with a soft dry cloth then let it air dry Do not dry the CD DVD BD using devices such as a hair dryer e To avoid dust damage and deformation keep the CD DVD BD in its case whenever it is not in use e Donotstore CDs DVDs BDs at high temperatures Areas exposed to prolonged direct sunlight or near heating appliances are to be avoided You can prevent damage from the optical drive and the CDs DVDs BDs as well as premature wear of the disks by observing the following suggestions Only insert disks in the drive when needed and remove them after use Store the disk
11. event of a LAN transfer rate of 100 Mbit s Remains dark in the event of a LAN transfer rate of 10 Mbit s Li Depending on the settings in the BIOS the standard LAN connector 1 may also be used as a Management LAN connector You will find further information in the D3343 BIOS Setup Utility for FUJITSU Server PRIMERGY CX2550 M1 Reference Manual 42 Operating Manual CX2550 M1 Starting up and operation 6 2 Switching the server node on and off The multi node server system consists of up to four server nodes Each server node installed in the server enclosure works independently The server nodes are controlled via related operating panel areas on the front side of the CX400 M1 server enclosure See FUJITSU Server PRIMERGY CX400 M1 Server Enclosure Operating Manual CAUTION e It nothing appears on the screen but flickering stripes after switching on the server node switch the server node off immediately see chapter Troubleshooting and tips on page 51 e The On Off button does not disconnect the server node from the mains voltage To completely disconnect it from the mains voltage remove the power plug s from the socket s e Do not move strike or shake the server node when it is turned on This can damage the hard disk in the server node and cause data loss e Turn the server node on when the temperature is in its operating environment range 10 C 40 C For details on the operating envi
12. product please check for additional information that may be available under the following URL http jp fujitsu com platform server primergy products note Further sources of information ServerView Suite Glossary Manual for the monitor Documentation for the boards and drives Operating system documentation Information files in your operating system 1 3 Notational conventions The following notational conventions are used in this manual Text in italics indicates commands or menu items Quotation marks indicate names of chapters and terms that are being emphasized gt describes activities that must be performed in the order shown CAUTION pay particular attention to texts marked with this symbol Failure to observe this warning may endanger your life destroy the system or lead to the loss of data i indicates additional information notes and tips CX2550 M1 Operating Manual 9 Introduction 10 Operating Manual CX2550 M1 2 Functional overview 2 1 Features This section provides information on the features and technical data of the PRIMERGY CX2550 M1 Server Node For information on key characteristics and layout of the system board see FUJITSU Server PRIMERGY CX2550 M1 Server Node Upgrade and Maintenance Manual System board The features of the system board are described in the FUJITSU Server PRIMERGY CX2550 M1 Upgrade and Maintenance Man
13. servers in 2 height units It is ideal for cloud cluster and high performance computing scenarios as well as in dedicated Big Data environments Combined in a PRIMERGY CX400 M1 multi node system the servers provide an aggregated scale out performance of a total of 8 CPUs of the latest Intel Xeon processor E5 2600 v3 product family 64 DDR4 memory DIMMs and up to 24 storage drives in a condensed 2 U rack enclosure With a huge performance potential high energy efficiency and at the same time attractive investment costs the PRIMERGY CX2550 M1 provides great versatility to match even ambitious workloads The highly compact server node occupies the half width of one height unit HU in the server enclosure 1 1 Concept and target groups for this manual This operating manual describes how to install set up and operate your server node This operating manual is intended for those responsible for installing the hardware and ensuring that the system runs smoothly It contains all the information you need to put your PRIMERGY CX2550 M1 server node into operation To understand the various expansion options you will need to be familiar with the fields of hardware and data transmission and you will require a basic knowledge of the underlying operating system CX2550 M1 Operating Manual 7 Introduction 1 2 Documentation overview More information on your PRIMERGY CX2550 M1 server node can be found in the following documents
14. the USB connectors of the server node gt Connect the monitor to the video connector If a separate graphics card is installed in a slot the graphic controller i on the system board is automatically deactivated The corresponding video connector can not be used Plug the video cable of the monitor into the video connector of the graphics card gt Connect the power cord of the monitor to the mains socket strip of the rack The rated current for the monitor is indicated on the technical data label on the monitor or in the operating manual for the monitor 36 Operating Manual CX2550 M1 Hardware installation 5 33 Notes on connecting disconnecting cables CAUTION Always read the documentation supplied with the device you wish to connect Never connect or disconnect cables during a thunderstorm Never pull on a cable when disconnecting it Always take hold of the cable by the plug Follow the sequence described below to connect or disconnect external devices to or from the server node Be sure to wait for 10 seconds or more after shutdown before turning the server node on Connecting cables gt Turn off all power and equipment switches gt Disconnect all power plugs from the properly grounded power outlets gt Connect all cables to the server node and peripherals gt Plug all data communication cables into the utility sockets gt Plug all power cords into the properly grounded power outlets Discon
15. the server node 1 4 422 11 46 Configuring the onboard SATA controller 46 Configuring the SAS SATA RAID controller 46 Operating system installation 47 Cleaning the server node 2 2 4 2 412 1 1 1 48 Property and data protection 1 1 1 1 1 1 1 1 49 BIOS Setup security functions 1 1 1 1 1 1 49 Troubleshooting and tips 122412 1 1 1 51 Power on indicator remains unlit 11 51 Server node switches itself off 1 11 51 Screen remains blank 0 0000 sa 1 52 Flickering stripes on monitor screen 52 No screen display or display drifts 1 53 Incorrect date and time LI LL Lona aa a 1 1 1 54 System will not boot 2 0202 eee eee 54 Error message on screen i 1 a 54 Operating Manual CX2550 M1 1 Introduction The FUJITSU Server PRIMERGY CX scale out systems are the ideal basis for cloud hyper converged and high performance computing solutions They provide data centers as well as branch offices with massive computing power for virtualized environments complex calculations as well as consolidation and high availabilty scenarios The PRIMERGY CX2550 M1 is a compact server node enabling highest computing density with four independent
16. Corporation in the USA and other countries Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the USA and other countries Before reading this manual For your safety This manual contains important information for safely and correctly using this product Carefully read the manual before using this product Pay particular attention to the accompanying manual Safety Notes and Regulations and ensure these safety notes are understood before using the product Keep this manual and the manual Safety Notes and Regulations in a safe place for easy reference while using this product Radio interference This product is a Class A ITE Information Technology Equipment In a domestic environment this product may cause radio interference in which case the user may be required to take appropriate measures VCCI A Aluminum electrolytic capacitors The aluminum electrolytic capacitors used in the product s printed circuit board assemblies and in the mouse and keyboard are limited life components Use of these components beyond their operating life may result in electrolyte leakage or depletion potentially causing emission of foul odor or smoke As a guideline in a normal office environment 25 C operating life is not expected to be reached within the maintenance support period 5 years However operating life may be reached more quickly if for example the product is used in a hot envi
17. Operating Manual English FUJITSU FUJITSU Server PRIMERGY CX2550 M1 Server Node Operating Manual Edition November 2015 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual Your feedback helps us optimize our documentation to suit your individual needs Feel free to send us your comments by e mail to manuals ts fujitsu com Certified documentation according to DIN EN ISO 9001 2008 To ensure a consistently high quality standard and user friendliness this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001 2008 cognitas Gesellschaft f r Technik Dokumentation mbH www cognitas de Copyright and Trademarks Copyright 2015 Fujitsu Technology Solutions GmbH All rights reserved Delivery subject to availability right of technical modifications reserved All hardware and software names used are trademarks of their respective manufacturers The contents of this manual may be revised without prior notice Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual No part of this manual may be reproduced in any form without the prior written permission of Fujitsu Microsoft Windows Windows Server and Hyper V are trademarks or registered trademarks of Microsoft
18. Part 3 3 Environment class 2K2 EN 60721 IEC 721 Part 3 2 Temperature Operation 3K2 5 C 40 C with Cool safe ATD 10 C 35 C without Cool safe ATD Maximum temperature depends on type of CPU Transport 2K2 25 C 60 C Humidity 10 85 non condensing Condensation during operation must be avoided CX2550 M1 Operating Manual 17 Functional overview Compliance with regulations and standards Product safety and ergonomics International IEC 60950 1 2ed am1 Europe Safety EN 60950 1 2ed am1 EN 62479 EN 62311 Ergonomics ISO 9241 3 EN 2941 3 EK1 ITB2000 2013 USA Canada CSA C22 2 No 60950 1 07 2ed UL 60950 1 2ed Taiwan CNS 14336 China GB 4943 Electromagnetic compatibility International CISPR 22 Europe EN 55022 Class A EN 55024 EN 61000 3 2 EN 61000 3 3 ETSI 300386 USA Canada 47CFR part 15 Class A ICES 003 Taiwan CNS 13438 Class A China GB 9245 GB 17625 Japan VCCI Class A JEITA Korea KN 22 KN 24 CE marking to EU Low Voltage Directive 2006 95 EC directives Electromagnetic compatibility 2004 108 EC Restriction of hazardous substances 2011 65 EU Operating Manual CX2550 M1 3 Installation steps overview This chapter contains an overview of the steps necessary to install your server node Links take you to sections where you can find more detailed information about the respective steps gt First of all carefu
19. ain gt Switch on your server node 8 2 Server node switches itself off Server Management has detected an error gt Check the error list of System Event Log in ServerView Operations Manager or in the iRMC S4 web interface and attempt to eliminate the error CX2550 M1 Operating Manual 51 Troubleshooting and tips 8 3 Screen remains blank Monitor is switched off gt Switch on your monitor Screen has gone blank gt Press any key on the keyboard or gt Deactivate screen saver Enter the appropriate password Brightness control is set to dark gt Set the brightness control on the monitor to light For detailed information refer to the operating manual supplied with your monitor Power cable or monitor cable not connected gt Switch off the monitor and the server node gt Check whether the power cable is properly connected to the monitor and to the grounded power outlet gt Check whether the monitor cable is properly connected to the server node and monitor if it is plugged in with a connector If a separate graphics card is installed in the server node then the monitor cable must be connected to the graphics card gt Switch on the monitor and the server node 8 4 Flickering stripes on monitor screen CAUTION Switch off the server node immediately Risk of damaging the server node 52 Operating Manual CX2550 M1 Troubleshooting and tips Monitor does not support the set ho
20. all other expansions they may damage the system or violate the safety regulations Information on which system expansions are approved for installation can be obtained from our customer service center or your sales outlet The components marked with a warning notice e g lightning symbol may only be opened removed or exchanged by authorized qualified personnel Exception CSS components can be replaced The warranty is void if the server node is damaged during installation or replacement of system expansions Only set screen resolutions and refresh rates that are specified in the operating manual for the monitor Otherwise you may damage your monitor If you are in any doubt contact your sales outlet or customer service center Before installing removing internal options to from the server node turn off the server node all peripheral devices and any other connected devices Also unplug all power cords from the outlet Failure to do so can cause electric shock Do not damage or modify internal cables or devices Doing so may cause a device failure fire or electric shock Devices inside the server node remain hot after shutdown Wait for a while after shutdown before installing or removing internal options The circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity Before handling them first touch a metal part of the server node to discharge static electricity from your body
21. ctional overview 2 2 2 eee ee a es 11 2 1 Features caca eS eGR ES RES EE Se RE He we HSS 11 2 2 Server node specification 2442 11 1 15 3 Installation steps overview 1 41221111 19 4 Important information aaa aoaaa 21 4 1 Safety instructions a aaa aaa 1 1 1 1 21 4 2 CECOMIOWNIY ses cone eR Ad Keer bE di kaw HS 29 4 3 FCC Class A Compliance Statement 30 4 4 Transporting the server node 1 1 1 1 1 1 1 31 4 5 Environmental protection 1 2 aaa ee eae 31 5 Hardware installation 2 2 eee a 33 5 1 Unpacking the server node 1 1 1 1 1 1 1 34 5 2 Connecting devices to the server node 35 5 3 Notes on connecting disconnecting cables 37 5 4 Notes on connecting disconnecting tubes 38 CX2550 M1 Operating Manual Contents 6 1 6 1 1 5 1141 6 112 5 1 13 6 2 6 3 65 1 6 3 2 6 33 6 4 7 1 8 1 8 2 8 3 8 4 8 5 8 6 8 7 8 8 Starting up and operation w 1244211 1 39 Controls and indicators aaa aaa aaa aa 11 39 Controls and indicators on the server node 39 Control elements 2246042 4855 ee baka ERE 40 Global error indicator ID indicator CSS indicator 40 LAN indicators 0 00000 1 1 42 Switching the server node on and off 43 Configuring
22. e relevant European or international standards EN 61340 5 1 ANSI ESD 20 20 28 Operating Manual CX2550 M1 Important information Other important information e During cleaning observe the instructions in section Cleaning the server node on page 48 e Keep this operating manual and the other documentation such as the Upgrade and Maintenance manual documentation DVD close to the device All documentation must be included if the equipment is passed on to a third party 4 2 CE conformity 2004 108 EC regarding Electromagnetic Compatibility and 2006 95 EC Low Voltage Directive and the directive of the European Parliament and Council 2011 65 EU This is indicated by the CE marking CE Communaut Europ enne E The system complies with the requirements of the EC directives CX2550 M1 Operating Manual 29 Important information 4 3 FCC Class A Compliance Statement If there is an FCC statement on the device it applies to the products covered in this manual unless otherwise specified herein The statement for other products will appear in the accompanying documentation NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules and meets all requirements of the Canadian Interference Causing Equipment Standard ICES 003 for digital apparatus These limits are designed to provide reasonable protection against harmful inte
23. e server node to the place where you want to set it up gt Unpack all individual parts Keep the original packaging in case you want to transport the server node again applies only to EMEA market Check the delivery for any damage during transport gt Check whether the items delivered match the details on the delivery note gt Notify your supplier immediately should you discover that the items delivered do not correspond to the delivery note 34 Operating Manual CX2550 M1 Hardware installation 5 2 Connecting devices to the server node The additional connectors available on your server node depend on the expansion cards installed For further information refer to the FUJITSU Server PRIMERGY CX2550 M1 Server Node Upgrade and Maintenance Manual The standard connectors are marked with symbols and some are color coded ji ARA Figure 2 Connection panel of the server node Shared LAN connector LAN 1 4 2 x USB 3 0 connectors Standard LAN connector LAN 2 5 Video connector Management LAN connector N w Some of the devices that can be connected may require the installation and setting up of special software e g drivers see the documentation for the connected device Connect the desired devices to the server node CX2550 M1 Operating Manual 35 Hardware installation Connecting the keyboard mouse and monitor gt Connect the keyboard and mouse to
24. hielded Ethernet cabling has to comply with EN 50173 and EN 50174 1 2 standards or ISO IEC 11801 standard respectively The minimum requirement is a Category 5 shielded cable for 10 100 Ethernet or a Category 5e cable for Gigabit Ethernet Route the cables in such a way that they do not create a potential hazard make sure no one can trip over them and that they cannot be damaged When connecting the server node refer to the relevant instructions in this manual Never connect or disconnect data transmission lines during a storm risk of lightning hazard Make sure that no objects e g jewelry paperclips etc or liquids can get inside the server node risk of electric shock short circuit In emergencies e g damaged casing controls or cables penetration of liquids or foreign bodies switch off the server node immediately remove all power plugs and contact your sales outlet or customer service team CX2550 M1 Operating Manual 23 Important information CAUTION Proper operation of the system in accordance with IEC 60950 1 2 resp EN 60950 1 2 is only ensured if the casing is completely assembled and the rear covers for the installation slots have been fitted electric shock cooling fire protection interference suppression Only install system expansions that satisfy the requirements and rules governing safety and electromagnetic compatibility and those relating to telecommunication terminals If you inst
25. ironment this product may cause radio interference in which case the user may be required to take adequate measures 30 Operating Manual CX2550 M1 Important information 4 4 Transporting the server node CAUTION Only transport the server node in its original packaging or in packaging that protects it from impacts and jolts Do not unpack the server node until it is at its installation location 4 5 Environmental protection Environmentally friendly product design and development This product has been designed in accordance with the Fujitsu standard for environmentally friendly product design and development This means that key factors such as durability selection and labeling of materials emissions packaging ease of dismantling and recycling have been taken into account This saves resources and thus reduces the harm done to the environment Further information can be found at hitp fs fujitsu com products standard_servers index html for the global market http jp fujitsu com platform server primergy concepi for the Japanese market Energy saving information Devices that do not need to be constantly switched on should be switched off until they are needed as well as during long breaks and after completion of work Packaging information This packaging information doesn t apply to the Japanese market Do not throw away the packaging You may need it later for transporting the system If possible the e
26. lly read the safety instructions in Important information on page 21 Transport the server node to the place where you want to set it up Unpack the system check the contents of the package for visible transport damage and check whether the items delivered match the details on the delivery note see section Unpacking the server node on page 34 Make sure that you have all necessary manuals see Documentation overview on page 8 print out the PDF files if required Components that have been ordered additionally may be delivered loose with the server node For mounting refer to the original component documentation Wire the server node Follow the instructions in sections Connecting devices to the server node on page 35 and Notes on connecting disconnecting cables on page 37 Familiarize yourself with the controls and indicators on the front and rear of the server node see section Controls and indicators on page 39 CX2550 M1 Operating Manual 19 Installation steps overview gt Configure the server node and install the desired operating system and applications The following options are available Remote installation with the ServerView Installation Manager With the ServerView Suite DVD provided you can configure the server node and install the operating system in a convenient manner Details on how to operate the ServerView Installation Manager as well as some additional information are included in the
27. mergy manual i For RAID management use the tool MegaCLI available via download 6 3 2 Configuring the SAS SATA RAID controller The server node has a SAS SATA RAID controller with MegaRAID functionality You can configure the SAS SATA RAID controller either before or during installation with the ServerView Installation Manager Using the ServerView Installation Manager is recommended Descriptions of operating systems not covered in the controller manual are provided in the corresponding readme files on the driver CDs 46 Operating Manual CX2550 M1 Starting up and operation 6 3 3 Operating system installation When starting up a PRIMERGY CX2550 M1 server node for the first time there are several installation options depending on the system configuration Local USB installation Instead of network booting you can also boot and install your PRIMERGY CX2550 M1 server node from local USB media gt Connect a USB storage medium hard disk drive optical drive or flash media containing a bootable image to your server gt Connect a USB mouse keyboard and VGA display to your server gt Switch on the display gt Make sure that none of the servers from your network has been dedicated to be a PXE server gt Press the On Off button item 2 in figure 3 on page 39 Your PRIMERGY CX2550 M1 server node will boot from the local disk image gt Follow the on screen instructions iSCSI boot iSCSI Internet
28. n of the power switch can be specified as Do Nothing Stand by Hibernate and Shutdown depending on the OS settings The default is Shutdown On this server functions corresponding to Stand by and Hibernate are not supported as BIOS and hardware functions For details about operating mode settings refer to the manual supplied with the OS CX2550 M1 Operating Manual 45 Starting up and operation 6 3 Configuring the server node 6 3 1 Configuring the onboard SATA controller If RAID mode is enabled you can configure the onboard SATA aj controller during boot up Native mode is also released For further information refer to D3343 BIOS Setup Utility for FUJITSU Server PRIMERGY CX2550 M1 Reference Manual If RAID mode is enabled the RAID must be configured during boot up to use hard disk drives For further information refer to the Embedded MegaRAID Software User s Guide on the Fujitsu manuals server under x86 Servers Expansion Cards Storage Adapters LSI RAID SCSI Controllers The PDF files of the manuals can also be downloaded free of charge from the Internet The overview page showing the online documentation available on the Internet can be found using the URL for EMEA market hitp manuals ts fujitsu com The PRIMERGY server documentation can be accessed using the x86 Servers navigation option For the Japanese market please use the URL http jp fujitsu com platform server pri
29. necting cables gt Turn off all power and equipment switches gt Disconnect all power plugs from the properly grounded power outlets gt Unplug all data communication cables from the utility sockets gt Disconnect the relevant cables from the server node and all the peripherals For connecting or disconnecting LAN cables the server node does not need to be powered off To avoid loss of data teaming function has to be enabled CX2550 M1 Operating Manual 37 Hardware installation 5 4 Notes on connecting disconnecting tubes If you have installed a liquid cooling system in the server node you have to connect the tubes of the liquid cooling system to the tube system of the rack CAUTION Always read the documentation RackCDU Service Manual to connect the tubes correctly Connecting tubes gt Turn off all power and equipment switches gt Disconnect all power plugs from the properly grounded power outlets gt Connect the tubes to the tube system of the rack as described in the manual RackCDU Service Manual gt Plug all data communication cables into the utility sockets gt Plug all power cords into the properly grounded power outlets Disconnecting tubes gt Turn off all power and equipment switches gt Disconnect all power plugs from the properly grounded power outlets gt Unplug all data communication cables from the utility sockets gt Disconnect the tubes from the tube system of the
30. ng Details regarding the return and recycling of devices and consumables within Europe can also be found in the Returning used devices manual via your local Fujitsu branch or from our recycling center in Paderborn Fujitsu Technology Solutions Recycling Center D 33106 Paderborn Tel 49 5251 525 1410 Fax 49 5251 525 32 1410 32 Operating Manual CX2550 M1 5 Hardware installation CAUTION e Follow the safety instructions in the chapter Important information on page 21 e Do not expose the server node to extreme environmental conditions see Ambient conditions on page 17 Protect the server node from dust humidity and heat e Make sure that the server node is acclimatized for the time indicated in this table before putting it into operation Temperature difference C Minimum acclimatization time hours 5 3 10 5 15 7 20 8 25 9 30 10 Table 1 Acclimatization time In the table Acclimatization time the temperature difference refers to the difference between the operating environment temperature and the temperature to which the server node was exposed previously outside transport or storage temperature CX2550 M1 Operating Manual 33 Hardware installation 5 1 Unpacking the server node CAUTION Follow the safety instructions in Important information on page 21 Do not unpack the server node until it is at its installation location gt Transport th
31. ng e Browser access via IRMC S4 s own Web server e Secure communication SSH SSL e Power Management for the managed server depending on its system status 12 Operating Manual CX2550 M1 Functional overview e Power Consumption Management e Connecting virtual drives as remote storage e Text based and graphic console bypass Advanced Video Redirection e Remote Storage e Command Line Interface CLI e Simple interactive or script based IRMC S4configuration e Customer Self Service CSS e iRMC S4 s own user management e Multi computer global iRMC S4 user administration using an LDAP Directory Service e Automatic network configuration via DNS DHCP e Power supply of the IRMC S4 via the system standby supply e Full coverage alarm management e System Event Log SEL reading and processing e IPMI support e CIM WS MAN support e Internal Event Log for user login logout auditing More information about the IRMC S4 can be found in the IRMC S4 integrated Remote Management Controller user guide on the Fujitsu manuals server under x86 Servers Software ServerView Suite Out Of Band Management CX2550 M1 Operating Manual 13 ATD DUO Functional overview Cool safe Advanced Thermal Design The Cool safe Advanced Thermal Design option allows you to operate the system within a wider temperature range of 5 C to 40 C This option can only be ordered from the manufacturer and is d indicated
32. ontroller 1350 2 x 10 100 1000 Mbit s Ethernet TCP IP acceleration Remote Management Controller iIRMC S4 integrated Remote Management Controller IPMI 2 0 compatible SATA Controller Intel C610 for up to 6 x SATA HDDs SSDs SW Raid 0 1 RAID controllers expansion cards RAID controllers RAID Ctrl SAS SATA 12 Gbit s Fujitsu PRAID CP400i 8 ports int RAID level 0 1 1E 10 5 No BBU support RAID 5 6 Ctrl SAS SATA 12 Gbit s Fujitsu PRAID EP420i 8 ports int RAID level 0 1 10 5 50 6 60 2 GB RAID 5 6 Ctrl SAS SATA 12 Gbit s Fujitsu PRAID EP400i 8 ports int RAID level 0 1 10 5 50 6 60 1 GB Optional FBU based on LSI SAS3108 Slots PCI Express 3 0 x 16 2 xfor low profile via riser card Drives Hard disk bays 6 x 2 5 inch Operating Manual CX2550 M1 Functional overview Operating Panel Operating buttons ID button On Off button Operating LEDs On Off green System status orange LAN speed green orange LAN connection green Identification blue Dimensions Weight Rack W x D x H 1 HU half wide 175 5 mm x 520 mm x 40 8 mm Weight 4 kg full populated incl PCI expansion cards SKD 2 kg Weight notes actual weight may vary depending on configuration Ambient conditions Environment class 3K2 EN 60721 IEC 721
33. quipment should only be transported in its original packaging Information on handling consumables Please dispose of printer consumables and batteries in accordance with the applicable national regulations CX2550 M1 Operating Manual 31 Important information In accordance with EU directives batteries must not be disposed of with unsorted domestic waste They can be returned free of charge to the manufacturer dealer or an authorized agent for recycling or disposal All batteries containing pollutants are marked with a symbol a crossed out garbage can They are also marked with the chemical symbol for the heavy metal that causes them to be categorized as containing pollutants Cd Cadmium Hg Mercury Pb Lead Labels on plastic casing parts Please avoid sticking your own labels on plastic parts wherever possible since this makes it difficult to recycle them Returns recycling and disposal Please handle returns recycling and disposal in accordance with local regulations The device must not be disposed of with domestic waste This device is labeled in compliance with European directive 2002 96 EC on waste electrical and electronic equipment WEEE This directive sets the framework for returning and recycling used EE equipment and is valid across the EU When returning your used device please use the return and collection systems available to you Further information can be found at http ts fujitsu com recycli
34. rack as described in the manual RackCDU Service Manual 38 Operating Manual CX2550 M1 6 Starting up and operation CAUTION Please note the safety instructions in chapter Important information on page 21 6 1 Controls and indicators 6 1 1 Controls and indicators on the server node Figure 3 Controls and indicators of the server node RST button Global error indicator ID indicator CSS inidicator W N R The server nodes are controlled via related operating panel areas on the front side of the CX400 M1 server enclosure See FUJITSU Server PRIMERGY CX400 M1 Server Enclosure Operating Manual CX2550 M1 Operating Manual 39 Starting up and operation 6 1 1 1 Control elements RST Reset button Pressing the reset button reboots the system CAUTION Risk of loss of data The server nodes are controlled via related operating panel areas on the front side of the CX400 M1 server enclosure See FUJITSU Server PRIMERGY CX400 M1 Server Enclosure Operating Manual 6 1 1 2 Global error indicator ID indicator CSS indicator N Global error indicator orange Lights up orange if a prefailure event has been detected that requires precautionary service intervention Flashes orange if an error was detected that requires service intervention Does not light up if there is no critical event If the event is still acute after a power cycle the indicator is
35. rference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in strict accordance with the instructions may cause harmful interference to radio communications However there is no warranty that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between equipment and the receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help Fujitsu is not responsible for any radio or television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Fujitsu The correction of interferences caused by such unauthorized modification substitution or attachment will be the responsibility of the user The use of shielded I O cables is required when connecting this equipment to any and all optional peripheral or host devices Failure to do so may violate FCC and ICES rules WARNING This is a class A product In a domestic env
36. rizontal frequency gt Find out which horizontal frequency your monitor screen supports You will find the horizontal frequency also known as line frequency or horizontal deflection frequency in the documentation for your monitor Refer to the documentation for your operating system or the software for the screen controller for details of how to set the correct horizontal frequency for your monitor and follow the procedure accordingly 8 5 No screen display or display drifts The wrong horizontal frequency or resolution has been selected for the monitor or for the application program gt Find out which horizontal frequency your monitor screen supports You will find the horizontal frequency also known as line frequency or horizontal deflection frequency in the documentation for your monitor Refer to the documentation for your operating system or the software for the screen controller for details of how to set the correct horizontal frequency for your monitor and follow the procedure accordingly CX2550 M1 Operating Manual 53 Troubleshooting and tips 8 6 Incorrect date and time gt Set the date and time in the operating system or in the BIOS Setup under the Main menu using System Date and System Time respectively Note that the operating system may affect the system time For example i the operating system time may deviate from the system time under Linux and would overwrite the system time in the defaul
37. ronment The customer shall bear the cost of replacing replaceable components which have exceeded their operating life Note that these are only guidelines and do not constitute a guarantee of trouble free operation during the maintenance support period High safety use This product has been designed and manufactured to be used in commercial and or industrial areas as a server When used as visual display workplace it must not be placed in the direct field of view to avoid incommoding reflections applies only to TX server systems The device has not been designed or manufactured for uses which demand an extremely high level of safety and carry a direct and serious risk of life or body if such safety cannot be assured CX2550 M1 Operating Manual These uses include control of nuclear reactions in nuclear power plants automatic airplane flight control air traffic control traffic control in mass transport systems medical devices for life support and missile guidance control in weapons systems hereafter high safety use Customers should not use this product for high safety use unless measures are in place for ensuring the level of safety demanded of such use Please consult the sales staff of Fujitsu if intending to use this product for high safety use Measures against momentary voltage drop This product may be affected by a momentary voltage drop in the power supply caused by lightning To prevent a momentary voltage drop
38. ronment refer to Safety Precautions When operating the device outside of this operating environment the server node may operate improperly damage data etc Furthermore Fujitsu cannot be held responsible for any related damage malfunction or loss of data etc e Be sure to wait for 10 seconds or more after shutdown before turning the server node on e After connecting the power cable press the On Off button after it passes for more than 10 seconds CX2550 M1 Operating Manual 43 Starting up and operation Switching the server node on gt Connect a USB storage medium hard disk drive optical drive or flash media containing a bootable image to your server gt Press the On Off button The power on indicator lights up green when the server node is connected to the mains Alternatively the power can be switched on off on the chassis front panel of the PRIMERGY CX400 M1 server enclosure Further information you can find in the FUJITSU Server PRIMERGY CX400 M1 Server Enclosure Operating Manual and in the FUJITSU Server PRIMERGY CX400 M1 Server Enclosure Upgrade and Maintenance Manual Starting up for the first time For the Japanese market please refer to IX C bI KEA KE SLY gt Insert ServerView Suite DVD in the DVD drive gt Follow the on screen instructions see also section Configuring the server node on page 46 System already installed The server node is switched on performs a s
39. s in suitable sleeves Protect the disks from exposure to heat and direct sunlight Laser information The optical drive complies with IEC 60825 1 laser class 1 CAUTION The optical drive contains a light emitting diode LED which under certain circumstances produces a laser beam stronger than laser class 1 Looking directly at this beam is dangerous Never remove parts of the optical drive casing CX2550 M1 Operating Manual 27 Important information Modules with Electrostatic Sensitive Devices Modules with electrostatic sensitive devices are identified by the following sticker A When you handle components fitted with ESDs you must always observe the following points Figure 1 ESD label e Switch off the system and remove the power plugs from the power outlets before installing or removing components with ESDs e You must always discharge static build up e g by touching a grounded object before working with such components e Any devices or tools that are used must be free of electrostatic charge e Wear a suitable grounding cable that connects you to the external chassis of the system unit e Always hold components with ESDs at the edges or at the points marked green touch points e Do not touch any connectors or conduction paths on an ESD e Place all the components on a pad which is free of electrostatic charge For a detailed description of how to handle ESD components see th
40. stalled server nodes and data internally against unauthorized access you can use the BIOS Setup security functions 7 1 BIOS Setup security functions The Security menu in BIOS Setup offers various options for protecting your data from unauthorized access By combining these options you can also achieve optimum protection for your system A detailed description of the Security menu and how to assign passwords can be found in the D3343 BIOS Setup Utility for FUJITSU Server PRIMERGY CX2550 M1 Reference Manual CX2550 M1 Operating Manual 49 Property and data protection 50 Operating Manual CX2550 M1 8 Troubleshooting and tips CAUTION Follow the safety instructions in the Safety notes and regulations manual or Z LQ 7i and in chapter Important information on page 21 If a fault occurs attempt to resolve it using the measures described in this chapter inthe documentation for the connected devices inthe help systems of the software used 8 1 Power on indicator remains unlit The power on indicator remains dark after you switch on your device Power cable incorrectly connected gt Make sure that the power cable s is are correctly connected to the server node and the grounded power outlet s Power supply overloaded gt Disconnect the server node power plug s from the grounded power outlet s gt Wait afew minutes before you plug it them into the grounded power outlet s ag
41. t do not relate to CSS failures shall be performed by service personnel Please note that unauthorized interference with the system will void the warranty and exempt the manufacturer from all liability e Any failure to observe the guidelines in this manual and any improper repairs could expose the user to risks electric shock energy hazards fire hazards or damage the equipment e Before installing removing internal options to from the server turn off the server all peripheral devices and any other connected devices Also unplug all power cords from the power outlet Failure to do so can cause electric shock CX2550 M1 Operating Manual 21 Important information Before starting up CAUTION During installation and before operating the device observe the instructions on environmental conditions for your device see Server node specification on page 15 If the server node has been moved from a cold environment condensation may form both inside and on the outside of the machine Wait until the server node has acclimatized to room temperature and is absolutely dry before starting it up Material damage may be caused to the server node if this requirement is not met Only transport the server node in the original packaging or in packaging that protects it from impacts and jolts Installation and operation CAUTION This unit should not be operated in ambient temperatures above 35 C For servers with Cool safe
42. t setting on shutdown If the date and time are still wrong after the server node has been switched off and back on again replace the lithium battery for a description refer to the FUJITSU Server PRIMERGY CX2550 M1 Server Node Upgrade and Maintenance Manual or contact our customer service team 8 7 System will not boot The system will not boot after installing a new hard disk drive SAS configuration incorrect Check the settings for the hard disk drives SAS Device Configuration and the additional settings in the SAS configuration menu 8 8 Error message on screen The meaning of the error message is explained in the documentation for the relevant components and programs on the Fujitsu manuals server 54 Operating Manual CX2550 M1
43. ual the setup possibilities are described in the D3343 BIOS Setup Utility for FUJITSU Server PRIMERGY CX2550 M1 Reference Manual Slots for expansion cards The server node can be flexibly expanded with two expansion cards PCle 3 0 x16 via riser card Onboard SATA controller A SATA controller is integrated on the system board up to six SATA HDDs or SSDs can be connected to the controller The software SATA Software RAID supports RAID levels 0 and 1 For more information on configuring the controller see section Configuring the SAS SATA RAID controller on page 46 SAS SATA RAID controller The server node is available with the following SAS SATA RAID controllers for operating the internal SAS SATA hard disk drives RAID Ctrl SAS SATA 12 Gbit s Fujitsu PRAID CP400i 8 ports int RAID level O 1 1E 10 5 No BBU support RAID 5 6 Ctrl SAS SATA 12 Gbit s Fujitsu PRAID EP420i 8 ports int RAID level O 1 10 5 50 6 60 2 GB Optional FBU based on LSI SAS3108 RAID 5 6 Ctrl SAS SATA 12 Gbit s Fujitsu PRAID EP400i 8 ports int RAID level 0 1 10 5 50 6 60 1 GB Optional FBU based on LSI SAS3108 CX2550 M1 Operating Manual 11 Functional overview For more information on configuring the controller see section Configuring the SAS SATA RAID controller on page 46 Further information on SAS SATA RAID controllers is provided in the Modular RAID Controller Installation Guide on the
44. with devices with optical drives these instructions must be followed CAUTION Only use CDs DVDs BDs that are in perfect condition in order to prevent data loss equipment damage and injury Check each CD DVD BD for damage cracks breakages etc before inserting it in the drive Note that any additional labels applied may change the mechanical properties of a CD DVD BD and cause imbalance Damaged and imbalanced CDs DVDs BDs can break at high drive speeds data loss Under certain circumstances sharp CD DVD BD fragments can pierce the cover of the optical drive equipment damage and can fly out of the device danger of injury particularly to uncovered body parts such as the face or neck High humidity and airborne dust levels are to be avoided Electric shocks and or server node failures may be caused by liquids such as water or metallic items such as paper clips entering a drive Shocks and vibrations are also to be avoided Do not insert any objects other than the specified CDs DVDs BDs Do not pull on press hard or otherwise handle the CD DVD BD tray roughly Do not disassemble the optical drive Before use clean the optical disk tray using a soft dry cloth As a precaution remove disks from the optical drive when the drive is not to be used for a long time Keep the optical disk tray closed to prevent foreign matter such as dust from entering the optical drive Hold CDs DVDs BDs by their edges to avoid
45. ystem test and boots the operating system In the case of configurations with a large memory size the boot process may be prolonged and the screen may remain dark for about 20 seconds Switching the server node off gt Shut down the operating system properly The server nodes are controlled via related operating panel areas on the front side of the CX400 M1 server enclosure See FUJITSU Server PRIMERGY CX400 M1 Server Enclosure Operating Manual If the operating system does not switch the server node off automatically press the On Off button for at least four seconds and or send a corresponding control signal for power button override 44 Operating Manual CX2550 M1 Starting up and operation Other On Off options Besides the On Off button the server can be switched ON and OFF in the following ways Wake up On LAN WOL The server is switched on by a command via the LAN Magic Packet After power failure The server automatically reboots following a power failure depending on the settings in the BIOS or in iRMC S4 Power button override The system can be switched off hard power off by holding down the On Off button approximately 4 5 seconds CAUTION There is a risk that data may be lost iRMC S4 iRMC S4 offers various options for switching the server on and off e g via the Power On Off page of the iRMC S4 Web interface CAUTION when turning the power off Windows Server 2008 The operatio