1. EEE Relay 2 time switch MOZY currently no function EY kriki tr Ee Relay 1 door opener gree sper Power supply input 12 VDC 24 VDC cA Gi VDC out reversible fuse A Note J If the KAPI interface is occupied the media readers READER RFID1 RFID2 will not work The respective LED will no longer light up 5 1 1 LED display wue y Terminal Id LED Comment KESO reader READER Lights if communication with a KESO reader exists Ifthe KAPI programming cable is connected the display will go off and the KESO reader will be taken out of operation The red and green LEDs flash on the KESO reader Input open closed DOOR Lights when the input is connected with GND Input locked unlocked BOLT I Lights when the input is connected with GND Input exit request EXIT Lights when the input is connected with GND Relay 2 NC1 COM Lights when relay 2 is activated Relay 1 NC2 COM Lights when relay 1 is activated Function LED POWER __ Steady light indicates that the KESO When power supply input IN AccessPoint is working is present Flashing with 1 Hz indicates that the KESO AccessPoint has not yet been programmed with KESO k entry factory set always on Rapid flashing indicates that the KESO AccessPoint is not verified Commissioning is not possible Contact your solution centre Failure to light up indicates that the device is defective or there is
2. KESO AG accepts no claims under warranty and no liability in cases where unauthorised modifications or improper installation contrary to our assembly instructions is performed or brought about Installation Installation regulations are national regulations Therefore please observe your country s legislation For Switzerland the following applies EJ Electrical installations may only be carried out by qualified personnel Disposal Z All articles listed in this documentation must not be disposed of as normal household R waste It is the consumer s responsibility to dispose of the product at a recycling collection point for electrical and electronic waste Disposing of this waste separately helps to optimise reprocessing of all materials suitable for recycling and to reduce health and environmental risks For more information on the correct disposal of this product please contact the retailer you purchased it from General safety instructions AN Instructions concerning the safety of the user and avoidance of damage to the device A Caution mains power Instructions you must follow to ensure trouble free operation gt A This product contains electronic components which are sensitive to electrostatic discharge ESD Electrostatic discharge may occur if touched by people or objects and will cause temporary or permanent damage to the product In order to eliminate the risk of electrostatic discharge follow the handling instruct
3. a label on the upper side of the power supply The diameter of the cables must not be less than 0 75mm The screws of the terminals must be tightened properly Ensure that the mains power supply is interrupted before disassembling Then remove the cables from the terminals and insulate the ends of the wires correctly Safety measures Non observance of these measures could result in fatal or serious injuries The AccessPoint must never be connected to an unspecified or inadequately specified power source The terminals of the ET AccessPoint must not be connected to the AC mains network The power supply lines must not be damaged or pinched Connections should never be made with wet hands The terminals and the input and output cables must not be short circuited Never deform open or drill through the power supply unit The power supply unit and the supply line must be kept free of condensation and dust Safety precautions No connections whatsoever may be made or fitted while electric current is flowing This can cause electric shocks or damage to materials Before supplying electric current always ensure that the cables are neither damaged nor short circuited Flames or electric shocks could result Prohibitions The power supply must never be connected to the positions listed below as this could lead to damage to the operation and presents a great danger of electric shocks and flames Positions that are not solely accessible to qualified person
4. if the setting is incorrect Unlocking time The field is only active if External antenna is selected The relay switching time can be set between 0 5 and 99 0 seconds Use Office shop function The office shop function modifies the always open function to prevent it from starting automatically in the respective time slot The always open time slot is not activated or deactivated until a defined and authorised office key or office master key is presented to the reader module For authorisations see KEK authorisations in the KESO k entry Management Software Use deliberate action Only active when Office shop function is selected If this function is activated this means that the data carrier must be presented to the KESO reader for approx 2 seconds in order to switch on or switch off the Office shop function Door monitoring Function is only activated by means of the KESO AccessPoint ET online 6 5 2 Functional check KESO AccessPoint SA The KESO AccessPoint SA must be reprogrammed whenever the device properties are changed Then check the LED display on the KESO AccessPoint SA and test the functions by means of an authorised data carrier KESO AG 06 2011 Subject to alterations Page 18 of 28 KESO AccessPoint ASSA ABLOY 6 6 Commissioning the KESO AccessPoint ET online Please see the KESO KEK net documentation see section 2 1 Further applicable documents KESO KService in version V4 30 and later i
5. no power supply Ethernet connection TCP IP Lights when connected with 100 Mbps Flashes during data transmission at 100 Mbps __ Lights when connected with 10 Mbps _ Flashes during data transmission at 10 Mbps KESO AG 06 2011 Subject to alterations Page 11 of 28 KESO AccessPoint ASSA ABLOY 5 2 Connection diagrams 5 2 1 KESO K 548 K 549 K 550 readers with KESO AccessPoint Switch setting to pos 2 for KESO AccessPoint 5 2 1 1 Connection diagram KESO reader rear side from left to right KESOreader A gt KESO AccessPoint A yellow KESO reader A gt KESO AccessPoint A white KESO reader gt KESO AccessPoint blue KESO reader gt KESO AccessPoint white IdV m ad 0 wt tts wo TF Tews w 3d gour wz gy ae AZojouyra Aey U0 yYIOMIAU OS JUIOgssady SHIELD IE GND 12 24v0C Twisted pairs of wires KESO AG 06 2011 Subject to alterations Page 12 of 28 KESO AccessPoint ASSA ABLOY 5 2 2 KESO K 548 K 549 K 550 readers with KESO EG 709 reader and adapter PCB Switch setting to pos 4 for EG 709 electronics Connection terminals for KESO reader 1 EARTH EARTH 2 grey Rx 3 pink Rx Connection terminals for KESO reader A brown B white yellow green VIN 12 24 V 5 2 2 1 Connection diagram KESO reader rear side from right to left KESO reader A gt EG 709 adapter
6. terminal KESO K 501 small antenna reader e Same functionality as the present EG 709 e Cannot be operated as a NOK terminal e In combination with the KESO AccessPoint the small antennas can be operated with extension cables of up to eight metres e Amaximum of two KESO small antennas can be connected Note Programming for the two KESO small antennas is identical Possible application for entry and exit by means of one door KESO MOZY eco e Must be powered by its own power supply unit 12 VDC e Additional door contacts must be fitted for monitoring the door status KESO AG 06 2011 Subject to alterations E Page 7 of 28 KESO AccessPoint 4 2 43 Technical information about the KESO AccessPoint Power supply only model EG 715 stabilised power supply unit 12 VDC 24 VDC Ethernet Programming interfaces Door monitoring Outputs Tamper contact Status displays RFID Temperature and humidity Protection level Operating temperature Storage temperature Humidity Product service life Standards RJ45 with integrated LED yellow green 10 100 Mbps Ethernet interface DHCP static IP EN55022 and EN55024 KAPI connection in combination with KESO KEK Programmer PPG V2 Inputs open closed locked unlocked exit request Relays door opener time switch MOZY eco on request Inputs relays operating status with LED Small antenna KEK Genie cylinder KESO reader IEC 68 2 1 2 3 14 IP20 AP c
7. terminal 2 brown KESO reader B gt EG 709 adapter terminal 3 white KESO reader gt EG 709 adapter terminal 1 yellow KESO reader gt EG 709 adapter terminal 4 green KESO reader 1 gt EG 709 adapter terminal 7 EARTH KESO reader 2 gt EG 709 adapter terminal 6 grey KESO reader 3 gt EG 709 adapter terminal 5 pink KESO AG 06 2011 Subject to alterations Page 13 of 28 KESO AccessPoint ASSA ABLOY 5 2 3 KESO reader K 528 K 529 K 547 with KESO AccessPoint Older KESO readers K 528 K 529 K 547 can also be connected to the KESO AccessPoint Note A Since older KESO readers do not have buzzers these cannot and must not be used as Network on Key NOK Terminals 5 2 3 1 Connection diagram KESO reader rear side from left to right KESO reader 1 gt KESO AccessPoint blue KESO reader 2and5 bridge gt KESO AccessPoint A yellow KESO reader 3and 6 bridge gt KESO AccessPoint B white KESO reader 4 gt KESO AccessPoint white KESO reader 7 gt not used IdV A ad w N gv ww wt tts wo TP Tews wi goer ugg pge 3ojouy2 Ady U0 IOMIAU OSJJ IUOdJsSS DHY SHIELD If GND 12 24v0C Twisted pairs of wires KESO AG 06 2011 Subject to alterations Page 14 of
8. 1 00 NTU12 0 50 Specification Input VA i Description KESO network on key technology 88x88x7 3 mm LxWxH Thermoplastic blend of polymers white 10 to 60 C 10 to 95 non condensing IP20 88 0 Description Power supply unit switch 230 V 12 V 1 0A Power supply unit switch 230 V 24 V O 5A 230 V 10 48 63 Hz Reso Output NTU12 1 00 12 VDC 1 A Output NTU12 0 50 24 VDC 0 5 A Nominal Power 12 W Operating temperature 5 to 50 C Safety in accordance with EN61558 EN60950 J You will find more power supply units in our main catalogue or in the current price list KESO AG 06 2011 Subject to alterations Page 24 of 28 KESO AccessPoint Explanation of terms RFID KEK net TCP IP NOK AccessPoint ET AccessPoint SA Master Slave NC NO COM Serial k entry KService KComm PPG V2 KAPI Radio Frequency Identification KESO components for programming via Ethernet Transmission Control Protocol Internet Protocol Network on Key based on KEK Combi keys AccessPoint for Ethernet operation online AccessPoint for stand alone operation offline hierarchical administration of accesses to a common resource Normally Closed rest contact Normally Open actuating contact Common shared connection Digital input output KESO Management Software for administering locking systems KEK net service for online doors KESO k entry interface to KService or KESO KEK Progr
9. 28 KESO AccessPoint 5 2 4 5 2 4 1 5 2 5 5 2 5 1 KESO AG 06 2011 ASSA ABLOY K 501 small antenna with KESO AccessPoint Up to two KESO K 501 small antennas can be connected to the KESO AccessPoint The KEK authorisations are identical on both small antennas di dDL IdV DOOR 2 gt marre GND a gt EREN 4 ose coms BOLT 3 nA beeline g GND 7 Fes ces ao oO m m s54 EXIT 2 AR on N vo EEE o NC 2 Z TIME z NO 2 o a eesse 9 COM 2 J M lt NC 1 a LOCK oe NO 1 o S Ses 5 COM 1 w z SHIELD If aa GND GND 1A max Z 12 24 voc Cable length settings The dip switches for setting the cable lengths are positioned between the two RFID connections The possible settings can be seen in the figure Note The metre values are guidelines ws ft fits wo fg gus w St EET ugg ERvz KEK Genie BS cylinder with KESO AccessPoint KESO KEK Genie BS cylinders with KEK functionality on both sides can be connected to the KESO AccessPoint The KEK authorisations are identical on both halves of the KESO KEK Genie BS cylinders A A gt B e a DOOR gt Bpm GND a gt Eee u fs ean O s BOLT 5 a kedas e GND Bce 2 S a gt z fe a s4 ans H E E re NC 2 gt TIME z NO2 o x COM 2 Je 2 NC 1 a LOCK oe NO 1 o A S COM 1 3 SHIELD If VDC T GND amp GND 1A max Z 12 24 voc Cable length settings The dip switches for settin
10. ET and test the functions by means of an authorised data carrier 6 7 Approval amp documentation KESO AG recommends that an approval protocol is signed by the end user after installation and commissioning In addition door documentation should be given to the end user ay The professional door concept planning software KESO TKP from KESO AG views lt 7 doors as functional units The documentation guarantees you an overview of the doors in the building and enables you to access the data required at any time e g for repairs or taking inventories 7 Accessories and individual parts 7 1 KESO KEK Genie cylinder Entire KESO KEK Genie BS range with new actuator Available as from 2nd quarter of 2010 You will find the KESO KEK Genie BS range in our main catalogue or in the current price list for 2010 onwards 1 2 AP casing Item No Description V 000 21 49 Empty casing white without screws 7 3 Cable 4 wires Item No Description K 551 01 Serial 10 m twisted pairs K 551 05 Serial 50 m twisted pairs K 551 10 Serial 100 m twisted pairs 7 3 1 Specification Cable length T T G51 PVC 2x2x 0 6 gr Cable colours yellow amp white twisted blue amp white twisted Diameter 5 6 mm Cable ends not prepared r The cable is prepared for fixed installations and may not be used for moveable cable transitions KESO AG 06 2011 Subject to alterations Page 21 of 28 KESO AccessPoint ASSA ABLOY 7A KESO reader surfac
11. KESO AccessPoint Documentation Introduction Product description Ordering details Technical data Connections and display Commissioning Accessories and individual parts Explanation of terms Troubleshooting FAQ possible faults Maintenance Care Repairs Service amp Support 1 2 3 4 5 6 T 8 9 1 1 ASSA ABLOY Issue date 22 06 2011 the global leader in Version 013 door opening solutions KESO AccessPoint ASSA ABLOY 1 2 Introduction This documentation belongs to the KESO AccessPoint product It contains important information on its use and commissioning For this reason you should familiarise yourself with the content and pay particular attention to the notes on safe handling operation and installation When passing on to third parties it must be ensured that they are also properly informed about handling the product Keep this documentation in a safe place for future reference This documentation is based on information that was correct at time of printing KESO AG accepts no liability for the correctness and completeness of the content of this documentation The figures or graphics shown may differ from the supplied components Q We reserve the right to make changes to reflect technical advancements S7 The manual is not covered by our Update Service KESO AG accepts no liability in case of data loss The configuration described in the following pages must be carried out by an approved solution centre
12. ammer KESO KEK programming device KESO Advanced Programming Interface Troubleshooting FAQ possible faults Symptoms Function LED does not light Possible cause Remedy Power supply input is not Check power supply input with connected voltmeter Power supply connection with Unplug VDC out incorrect polarity Short circuit on VDC out Function LED flashes rapidly 5 Hz Electronics neutral or defective Fit new electronics Function LED flashes slowly 1 Hz Factory set always on Program system data KESO reader not working KESO reader is not powered Check switch on KESO reader LEDs onthe KESO reader arenot Check wiring Yellow LED is not lit when a KESO lit Unplug KAPI reader is connected Wrong switch position on the KESO reader Cylinder is not read KESO AG 06 2011 KESO reader wired incorrectly Programming device KAPI is connected KESO reader firmware is not up to date Cable not connected Check cables and plugs Damaged cable or plug Try other RFID 1 RFID 2 switch Cylinder and extension cable positions connected incorrectly RFID1 RFID 2 switch position not optimal Keyis not authorised Subject to alterations Page 25 of 28 10 10 1 10 2 KESO AccessPoint ASSA ABLOY Maintenance Care Repairs To ensure trouble free operations of all electronics we recommend calling in an approved service partner Our solution centres will be pleased to give you detail
13. asing 20 to 50 C 40 to 90 C 10 to 95 non condensing 10 years EN 61000 6 2 3 EN 50364 EN 50357 ETSI EN 300 330 1 ETSI EN 301 489 3 EN61000 6 2 cable lengths lt 3 m with RFID1 and RFID2 Power supply input KESO AccessPoint Power supply Power supply voltage Power consumption Residual ripple Distance when centrally powered Terminals Stabilised power supply unit 12VDC 24VDC 12 24 VDC 10 max 4 W incl KESO reader or r KEK Genie cylinder without VDC out type 0 30 A 12 VDC type 0 15 A 24 VDC max 300 mVpp max 100 metres Plug in screwed terminals with reverse polarity protection We recommend KESO power supply units When using appliances from other AN manufacturers it must be ensured that they have protection class Such power supply units are marked with the protection class sign 0 KESO reader Interface Maximum length Cable specifications Recommended cables Power supply output Terminals RS485 unidirectional 100 metres Twisted pair 110 Ohm 0 6 mmA2 min 20 beats m Installation cable T T PVC G51 2x 2 x 0 6 gr Installation cable T T ISDN U72M 1x 4x 0 6 gu Related to the power supply input with 500 mA reversible fuse Plug in screwed terminals with reverse polarity protection The power supply unit must be sized accordingly to allow the reader supply to be short A circuited without the power supply unit switching off It must also be ensured tha
14. e mount Available as from 2nd quarter of 2010 C K 548 KESO network on key technology y T 7 4 1 Specification Size 87x87x65 mm LxWxH Material Thermoplastic Polyester dimensionally stable Petrol and oil resistant Colour white Operating temperature 10 to 60 C Humidity 10 to 95 non condensing Casing with M20 conduit inlet Protection rating IP55 1 4 2 Dimensional sketch Drainage opening can be broken out at the 1 4 3 Empty case K 514 KESO AG 06 2011 Subject to alterations Page 22 of 28 e wO KESO AccessPoint ASSA ABLOY 75 KESO reader flush mount Available as from 2nd quarter of 2010 s Item No Description Q K 549 KESO network on key technology a Q 7 5 1 Specification Size 87x87x23 mm LxWxH Material Thermoplastic Polyester dimensionally stable Petrol and oil resistant Colour white Operating temperature 10 to 60 C Humidity 10 to 95 non condensing Protection rating IP55 7 5 2 Drilling pattern Cover fastening 7 5 3 Replacement cover Item No Description K 511 Flush mount KESO AG 06 2011 Subject to alterations Page 23 of 28 KESO AccessPoint 1 6 7 6 1 1 6 2 1 1 0 1 KESO reader flush mount version EDIZIOdue Available as from 2nd quarter of 2010 Item No K 550 Specification Size Material Colour Working temperature Humidity Protection rating Dimensional sketch Power supply unit Item No NTU12
15. e places or damaged insulation e The protective covering must be mounted before commissioning 6 2 2 Work on the mains voltage 115 230 Volts may only be carried out by approved qualified personnel 6 2 3 Basic principles The maximum cable lengths and specifications must be observed for safe operation 6 2 4 Locking systems The power consumption ratings for locking components that is electrical openers drive cylinders motor locks switching locks etc are quoted in the data sheets for these products The total power consumption of the locking components and the KESO AccessPoint must not exceed the nominal output of the power supply unit Also observe the temperature range of the power supply unit when calculating its size 6 2 5 Ethernet cables The normal rules for IT installations apply for wiring the Ethernet 6 3 Installing the KESO AccessPoint Installation and assembly may only be performed by authorised KESO solution partners KESO AG 06 2011 Subject to alterations Page 16 of 28 KESO AccessPoint ASSA ABLOY 6 4 Door application The KESO AccessPoint is available in two versions online offline Various KESO products such as motorised locks electric openers and many more can be connected to the KESO AccessPoint Example Two KESO AccessPoint ET units online and one KESO AccessPoint SA offline 6 5 Commissioning the offline SA AccessPoint A KESO AccessPoint SA does not require any further components for opera
16. electronics can be programmed and read online once more The KESO KEK electronics can be programmed in offline as well as online mode by means of the KESO KEK Programmer PPG V2 KService Subject to alterations Page 19 of 28 KESO AccessPoint ASSA ABLOY 6 6 2 Programming the KESO AccessPoint ET with KESO k entry The KESO AccessPoint ET is programmed via Ethernet by means of the KESO k entry Management Software in combination with KESO K Service In the event of a network failure the KESO AccessPoint ET can also be programmed via the KESO KEK Programmer PPG V2 In addition to the programming options described in section 6 5 1 Programming the KESO AccessPoint SA with KESO k entryTM door monitoring can still be configured by means of the KESO k entry Management Software Properties KEK tab D Important In order to evaluate this function additional Reed contacts are required i on the door so that it can be monitored and evaluated Evaluation or signalling can take place e g via a drive control unit Zylinder Eigenschaften oc o OG Allgemein KEK Time KEK Info Gerat Unikatsnummer 00013071 Firmwareversion 04 00 00 21 Produktionsdatum 17 11 2009 Einstellungen 1 C Daueraut N C Stromlos offen lt C Erweiterte History 2 N S Exteme Antenne Entriegelungszeit 1 0 Sekunden Office Laden Funktion verwenden C Bewusste Handlung anwenden a M Tuiriiberwachung 1 For this select Door m
17. g the cable lengths for the KESO KEK Genie cylinder are positioned between the two RFID connections The possible settings can be seen in the figure Note The metre values are guidelines ws tts wg gus w St C Em ugg Ruz Subject to alterations Page 15 of 28 KESO AccessPoint ASSA ABLOY 6 Commissioning A The power supply must be switched off when carrying out any wiring work Fitters must check this themselves before connecting the cable 6 1 Installation re Installation and assembly must be performed by authorised KESO solution partners W Observe the installation guide your warranty is voided in case of improper use or installation Read this installation guide carefully before installing Observe the VDE German Electrical Engineering Association provisions and ESD regulations If you have any queries regarding installation please contact your dealer 6 2 Wiring To ascertain the cable lengths and network topology to use consider the possible distances between the required voltage and the access points in question A functional check must be carried out after each additional installation 6 2 1 Check the connections before turning on the power supply Pay particular attention to the following points e Mains voltage 115 230 Volts must never be connected anywhere to the KESO AccessPoint gt danger to life e The mains voltage on the power supply unit must be connected at 230 V e The cables must not show any bar
18. ience PB 01 013 _EN_KESO AccessPoint V013 doc
19. ions and recommendations in accordance with EN100015 1 Products should be transported and shipped in protective bags only KESO AG 06 2011 Subject to alterations Page 3 of 28 KESO AccessPoint ASSA ABLOY 1 2 1 1 2 1 1 1 2 1 2 1 2 1 3 1 2 1 4 Proper use The product may only be used for applications described in the catalogues and technical descriptions and only in connection with devices and components that are recommended and approved by KESO AG Any different or further reaching use is deemed improper KESO AG accepts no liability for any damages that may result from improper use and assumes no warranty for the error free and correct functioning of the components Proper use also includes the observation of all information given in the installation and operating instructions Correct transport storage set up and installation are essential for error free and safe operation of the product Danger of electric shocks Explanation regarding use and maintenance The power supplies for the AP models with power supply units may only be installed by approved qualified personnel It is essential to read these instructions for use before installing Use of the power supply is only permitted under the surrounding and operating conditions given on the label Ensure that the mains power supply is interrupted before connecting Before installing ensure that the input and output terminals are positioned correctly These can be recognised by
20. k entry Management Software and KESO KEK Programmer PPG V2 The firmware for the KESO KEK Programmer PPG V2 can be updated by means of the KESO k entry Management Software 3 Ordering details 3 1 1 KESO AccessPoint ET online with Ethernet in AP casing Item No Description EG 715 012 10 ET AP casing 12 VDC 1 0 A EG 715 024 05 ET AP casing 24 VDC 0 5 A EG 715 000 00 ET AP casing without power supply unit 3 1 2 KESO AccessPoint SA offline stand alone in AP casing Item No Description EG 715 012 10 SA AP casing 12 VDC 1 0A EG 715 024 05 SA AP casing 24 VDC 0 5 A EG 715 000 00 SA AP casing without power supply unit 3 1 3 KESO AccessPoint ET online with Ethernet for DIN profile Item No Description EG 716 000 00 ET DIN profile without power supply unit 3 1 4 KESO AccessPoint SA offline stand alone for DIN profile Item No Description EG 716 000 00 SA DIN profile without power supply unit 3 2 Packing units The versions of the product placed in circulation by us conform to the regulations of the European directives You will find the declaration of conformity in the package in each case 3 2 1 AP casing KESO AccessPoint mounted in an AP casing with integrated power supply unit Power supply unit optionally with 12 V 1 0 A or 24 V 0 5 A output and 230 V input voltage The own consumption of the KESO AccessPoint differs according to the power supply voltage You will find detailed information about the powe
21. nel In rooms and places with very low temperatures rays of direct sunlight near devices that cause great fluctuations in temperature e g cooling units refrigerators etc Positions that are very exposed to dampness and condensation such as bathrooms cellars greenhouses etc Positions that are exposed to particular environmental influences such as dust oil chemicals salt and similar substances Positions that are constantly subjected to vibrations or shocks Places that are exposed to flows of warm air or smoke near heating appliances or hot plates Outdoors or in the rain KESO AG 06 2011 Subject to alterations Page 4 of 28 KESO AccessPoint ASSA ABLOY 2 Product description The KESO AccessPoint meets the needs perfectly for safety and flexibility in modern buildings The new KESO AccessPoint is the ideal solution for the outer shells of building floor locking points or IT rooms where online monitoring is usually needed According to the relevant situation electronic KESO KEK Genie cylinders or KESO readers can be operated in real time In combination with the new KESO k entry Management Software authorisations can be managed centrally and doors monitored or opened automatically by means of a timer switch As from the 2nd quarter of 2010In addition the KESO Network On Key technology NOK allows administration and authorisation information to be exchanged between online and offline products by means of KEK combi keys ID cards
22. onitoring in the KEK tab under properties 2 You must then select configure Konfiguration Tirtiiberwachung _ Turkontakt L C Riegelkontakt 3 Door contact Is the door open or closed By additionally activating the Active open field contact open when door is closed the contact will be evaluated in reverse Depending on the Reed contact this status must be changed opener or closer 4 Bolt contact Is the door locked By additionally activating the Active open field contact open when door is locked the contact will be evaluated in reverse Depending on the Reed contact this status must be changed opener or closer 6 6 2 1 Display status in the KESO k entry Management Software ii Door is closed and locked Door is closed but not locked Door is open KESO AG 06 2011 Subject to alterations Page 20 of 28 KESO AccessPoint ASSA ABLOY 6 6 3 Functional check KESO AccessPoint ET In KESO KService check whether the KESO AccessPoint ET that is connected with the network is displayed correctly Then start the KESO k entry Management Software and check whether the device icons are displayed and whether communication with the KESO AccessPoint ET is working properly Programming is required each time the device properties are changed this is shown by an icon The KESO AccessPoint ET is programmed via the KESO k entry Management Software Then check the LED display on the KESO AccessPoint
23. or key tags Key online doors in the system such as main entrances thus become an update point for offline doors such as those fitted with KESO KEK i handle S HS KESO KEK Genie Knob or KESO KEK Genie BS Cylinder KESO Management ca Software 4 k entry ee Database KESO AccessPoint KESO KEK Genie BS C KESO AccessPoint KESO Reader 2 1 Further applicable documents The following documents describe the products that can be combined with the KESO AccessPoint e KESO AccessPoint installation manual BA 01 027 e KESO k entry Management Software BA 01 025 e KESO KEK Programmer PPG V2 PB 01 008 e KESO KEK net documentation PB 01 015 e KESO batchless documentation PB 01 010 e KESO KEK Genie BS documentation PB 01 011 2 2 Installation note Installations on mains power supplies must be carried out by approved qualified personnel KESO KEK net training by KESO AG is required in order to commission the KESO AccessPoint with Ethernet connection otherwise the installation must be carried out by an approved KESO KEK net partner 2 3 Documentation note This document describes the entire KESO AccessPoint range 2 4 Network connection The KESO AccessPoint ET is connected with the KESO k entry Management Software via KESO KEK net Ethernet KService administers the KESO KEK net connections on the server KESO AG 06 2011 Subject to alterations Page 5 of 28 KESO AccessPoint ASSA ABLOY 2 5 System Requirements KESO
24. r consumption under item 4 2 1 Power supply input KESO AccessPoint 3 2 2 DIN profile KESO AccessPoint mounted on a base for DIN profile installation without power supply unit KESO AG 06 2011 Subject to alterations Page 6 of 28 KESO AccessPoint Technical data Product compatibility Software e KESO k entry Management Software in version 5 0 5 2 onwards KESO KEK Programmer e KESO KEK Programmer PPG V2 with firmware version V1 02 Pro Rev E onwards Electronics firmware e KESO AccessPoint with firmware AIO V4 0 00 B10 onwards KESO reader surface flush mount K 548 K 549 K 550 from 2nd quarter of 2010 onwards e NOK terminals e Fully compatible e Incl buzzer for acoustic acknowledgement KESO KEK Genie BS cylinder e Same functionality as the present EG 708 e Cannot be operated as NOK terminals W Dr e In combination with the KESO AccessPoint the KESO KEK Genie BS cylinders can be operated with extension cables of up to eight metres e An emergency opening above the KESO KEK Genie cylinder is not possible e A maximum of two KESO KEK Genie BS cylinders can be connected Note Programming for the two KESO KEK Genie cylinders is identical Possible application KESO KEK Genie double cylinder for entry and exit KESO reader surface flush mount K 528 K 529 K 547 e Hardware from KEK_RS485_V1 3 onwards antenna PCB in the calibrate button e Same functionality as the present EG 709 e Cannot be operated as a NOK
25. riday between 07 30 and 12 00 and between 13 00 and 17 00 at 41 44 787 34 33 Our support staff can answer technical questions that directly concern KESO products O Personal KESO advice training We will gladly advise and train you personally if you have specialised questions about the products We will be happy to make you an offer Please note our programme of public courses O Personal KESO support If an error occurs or if you have a question for which the help menu does not have the answer and which cannot be resolved by telephone please fill out the support form in full and send to KESO AG support gt Fax 41 44 787 36 63 If you request personal support from KESO AG we will arrange an appointment and also inform you about any costs which may arise KESO AG 06 2011 Subject to alterations Page 26 of 28 ASSA ABLOY KESO AG Security systems Untere Schwandenstrasse 22 8805 Richterswil Switzerland Telephone 41 44 787 34 34 Fax 41 44 787 3535 Email info keso com Internet www keso com KESO GmbH Maurerstrasse 6 D 21244 Buchholz i d N Telephone 49 4181 924 0 Fax 49 4181 924 100 Email info keso de Internet www keso de KESO SA Succursale Suisse romande Zl Le Tr si 9B CH 1028 Pr verenges Telephone 41 218112929 Fax 41 218112900 Email keso sa keso com Internet www keso com ASSA ABLOY is the global leader in door opening solutions dedicated to satisfying end user needs for security safety and conven
26. s of maintenance contracts In all other cases please contact KESO AG who will provide the address of a qualified partner who will be pleased to contact you to discuss maintenance contract options and offer you a maintenance contract Firmware updates must be installed by the customer Error free functioning of the product cannot be guaranteed if you fail to update the firmware version The latest firmware can be downloaded from www keso com Wipe KESO products and accessories with a damp or antistatic cloth Never use aggressive cleaning agents or clean with silicon oil This can cause malfunctions Only use cleaning agents that contain no corrosive substances Never repair or modify KESO products or accessories Send defective devices or cables for repair to KESO AG or to one of our subsidiaries using the original packaging A Lb ESD Rules Static discharge can damage electronic components during installation or iN maintenance Never use defective electronics Product services ay Never repair KESO products or accessories Send defective devices in the original J packaging and accompanied by the delivery note to an authorised KESO dealer or to KESO AG for repairs Service amp Support Specialist trade service The first point of contact your dealer KESO support O Software and firmware updates http www keso com de site KESO Downloads Software O KESO telephone support You can reach our support staff from Monday to F
27. s required together with a respective KESO k entry Management Software licence There are no changes for the users apart from the additional KEK net licence in the KESO k entry Management Software The authorisation mutations and the device settings are handled in the background by online components via Ethernet KESO K Service D Important KESO solution partners must attend KESO KEK net training in order to certify for selling and commissioning the online components 6 6 1 Network settings KESO AccessPoint ET KESO AG 06 2011 The KESO AccessPoint ET is based on a standard Ethernet computer network The number of electronic units is theoretically infinite the only restriction is the number of IP addresses Thanks to the use of Ethernet the distance between the KESO k entry Management Software and the KESO AccessPoint ET is theoretically infinite Any limitations are solely related to the network topology The online electronics are marked with an additional icon in the KESO k entry Management Software This icon indicates whether the electronics are on the network and if the network connection is up In the event of a network failure any KESO KEK electronics will remain fully functional in offline mode In the offline state up to 500 history entries will be stored locally using the first in last out procedure When the online connection is restored the history data is immediately forwarded to KESO KService and the
28. ssPoint must be actuated VDC out The output is connected with the power supply voltage via a fuse This connector can be connected to the relay contacts Power supply output Related to the power supply input Protection 1 A reversible fuse Max output voltage The same as the connected power supply voltage Terminals Plug in screwed terminals with reverse polarity protection Power supply unit AP casing Safety standards EN61558 EN60950 Insulation class 1 Operating temperature 5 to 50 C Nominal input 230 VAC Nominal frequency 48 63 Hz Overload Protection Electronic KESO AG 06 2011 Subject to alterations Page 9 of 28 e KESO AccessPoint ASSA ABLOY 4 8 AP casing Dimensions 114x196x46 mm WxDxH Material ABS Colour white Gz 4 9 DIN profile Dimensions 83x100x48 mm WxDxH Can be snapped onto rails EN 60715 TH 35 7 5 EN 60715 TH 35 KESO AG 06 2011 Subject to alterations Page 10 of 28 KESO AccessPoint ASSA ABLOY 5 Connections and display A The power supply must be switched off when carrying out any wiring work All inputs and outputs are designed for 12 24 Volts Mains voltage 115 230 Volts must never be connected gt danger to life 5 1 KESO AccessPoint KAPI interface KESO reader Ethernet connection TCP IP Inputs open closed locked unlocked exit request 1 KEK cylinder small antenna Cable length adjustment 2 KEK cylinder small antenna a RUT
29. t a brief power interruption does not lead to unwanted effects on the connected components e g door openers KESO AG 06 2011 Subject to alterations Page 8 of 28 4 4 4 5 4 6 4 1 KESO AccessPoint ASSA ABLOY Inputs open closed locked unlocked exit request The inputs enable the door statuses to be displayed by the KESO k entry Management Software Actuation Internal pull up Active when connected with GND GND connections available on the terminal invertible with KESO k entry Management Software Status display Green function LED is lit when active Max input voltage The same as the connected power supply voltage Terminals Plug in screwed terminals with reverse polarity protection A Mains voltage must not be connected to the inputs gt danger to life If the connected contacts are used for other devices relays must be connected between them It is not possible to loop the contacts across several devices Relays door opener time switch MOZY Two external components can be switched with the two internal relays Contact 1 x Um potential free Maximum current 1 ADC 28 VDC Maximum voltage 30 VDC Status display Red LED lights when the relay is activated Terminals Plug in screwed terminals with reverse polarity protection A Mains voltage must not be connected gt danger to life If a 115 V 230 V consumer is to be switched an external relay separating the mains voltage from KESO Acce
30. tion apart from the power supply and a KESO reader or KESO KEK Genie cylinder KESO AG 06 2011 Subject to alterations Page 17 of 28 KESO AccessPoint ASSA ABLOY 6 5 1 Programming the KESO AccessPoint SA with KESO k entry The KESO AccessPoint SA is programmed by means of the KESO k entry Management Software in combination with the KESO KEK Programmer PPG V2 The following settings specific to the KESO AccessPoint SA can be set by means of the k entry KESO Management Software Properties KEK tab Zylinder Eigenschaften oc o 00 Allgemein KEK Time KEK Info 2 Ger t Unikatsnummer 3 Firmwareversion Produktionsdatum Einstellungen 4 E Dauerauf E Stromlos offen E Erweiterte History 5 Ez Externe Antenne Entriegelungszeit 1 0 ZA Sekunden F7 Office Laden Funktion verwenden 6 Bewusste Handlung anwenden DA T r berwachung 7 8 Always open Relay 1 is always active door is open Powerless open the always open command is given in the event of a drop in voltage The current threshold is approx 9 Volts Extended history Key removal is also recorded Only meaningful in combination with KEK Genie cylinders e g when using an electronic key depot External antenna This must be selected if a KESO reader RFID reader small antenna is in use Otherwise the RFID 1 and RFID 2 are configured for KEK Genie cylinders The KESO reader flashes red and green