engineering change notice (field change notice)

image

Contents

1. Organ 0040 0318 Organ to which Organ Dose ALWAYS AUTO Exposed 0040 0316 applies Value is BREAST Implant 0028 1300 Present Enumerated Value Anatomic 0008 2218 Region Sequence BREAST gt Code Value 0008 0100 Whether or not an implant is present ANAP Enumerated Values YES NO gt Coding 0008 0102 Scheme Designator USER Sequence that identifies the ALWAYS CONFIG anatomic region of interest in this USER Instance i e external anatomy surface anatomy or general region of the body Only a single Item shall be permitted in this sequence if a sequence item is ALWAYS USER Required if a sequence item is ALWAYS USER present ECN No 2012 E 0291Rev 1 72 72 e se Dicom Attribute Description Presence of Value Source 0008 0103 1C Required if a sequence item is ANAP USER present Required if the value of Coding Scheme Designator 0008 0102 is not sufficient to identify the Code Value 0008 0100 unambiguously me 0008 0104 Required if a sequence item is ALWAYS USER me present Partial View 0028 1350 Indicates whether this image is a ANAP AUTO partial view that is a subset of a Value is NO single view of the breast Enumerated Values YES NO If this Attribute is absent then the image may or may not be a partial view View Code 0054 0220 Sequence that describes the USER Sequence projection of the anatomic region of interest on the image rece
2. lt gt per E cir Menus are hidden if this SKULL Pena R 008 EA portion is blackened R MAMMOGRAPHY CC L MAMMOGRAPHY CC C SKULLAXL CEPHALOGRAPHY ZYGO AXL R MAMMOGRAPHY IT MAMMOGRAPHY MLO 01B SCHULLER MLO L SCHULLER R SCHULLER l NASAL BONE LAT l NASAL BONE AXL l STENVERS R MAMMOGRAPHY L MAMMOGRAPHY L STENVERS SPOT SPOT R STENVERS PARANASAL SINUS FRN MAMMOGRAPHY LACTIFEROUS DUCT C ti CHEST WALL NECK GENERAL PHARYNX LARYNX PHARYNX LARYNX FRN PHARYNX LARYNX LAT NECK PEDIATRICS OPEN MOUTH CERVICAL SPINE CERVICAL SPINE FRN switches displayed menus to nondisplay 5 3 Option key None Installation of CR IR 348CL DR ID 300CL PEM Key Software V1 0 114Y5342306A00 is required to use PEM processing 5 4 Details 5 4 1 Mammography study E Enabling the functionality Set up the following items Setup Configuration Item SYSTEM CONFIG 1 IMAGE MODALITY No Name ____________________ Area Defaultvalue Modality Setup 0 DX Specifying modality for study 1 CR 35 Modality Setup for Mammography 0 MG Specifying modality study Image 2 CR exclusively for vari Mt Modality for study Console determines the modality for the study according to setting combinations The following table describes the _ www MPMcode o www MPMcode o n s General study Mammography study Modality Setup Modality Setup for other than x3xx x3xx SI Image N
3. Do not change it from the default setting 5 4 3 W gradation parameter Do not change it from the default setting 5 4 4 Registration of implant information Do not change it from the default setting 5 4 5 Registration of View code View Modifier code Do not change it from the default setting 5 4 6 DICOM MG Storage for Presentation Do not select MG Image Storage For Presentation 5 4 8 XCON connection for mammography Do not change it from the default setting 5 5 1 Service Utility settings Do not change it from the default setting 5 5 2 Setting up marker BMP for mammography Do not perform the procedure ECN No 2012 E 0291Rev 1 32 39 Disabling mammography menu display in the User Utility Perform the following procedure to confirm that the Mammography BREAST menus are not displayed BREAST menus are not displayed under the normal condition Change display to hide them if they are displayed Switching display to nondisplay in the display group User Utility Menu Setting Select BREAST display group and click Change Display button lt The window where BREAST menus are hidden gt Menu Setting Clicking Change Display while selecting BREAST Display Setting rF posure Study Menu Edit Display Group E 9 Exposure Menu Study Menu Ki o0 PELVIS UPPER EXTREMITY LOWER EXTREMITY PORTABLE BREAST TOMOGR TOWNE 00 CALDWELL SELLA TURCICA FRN SKULL FRN
4. ECN No 2012 E 0291Rev 1 33 39 TCR RRC SOP class of supported DICOM Storage SOP class of supported DICOM Storage varies according to setting combinations The following table describes the combinations Supported DICOM Storage SOP Class _ _ Supported DICOM Storage SOP Class Modality Modality Setup CR Std CR Prv DX Pres DX Proc MG Pres MG Proc for Mammography Image Modality Setup 0 DX 0 MG Operational Operational General General Mammogr Mammography System setup limitation limitation study study aphy study P study v7 4 1 0 DX 1 CR Not supported 1 CR 0 MG General General Not Not Mammogr Mammography study study supporte supported aphy study Mammogra Mammogra d study V7 1 2 phy study phy study i General General Not Not Not Not supported study study supporte supported supported Mammogra Mammogra d 9 phy study phy study 1 Modality DX is output for general studies and modality MG is output for mammography studies Converting both studies into modality CR for output is an operational limitation 2 General studies are converted into modality CR modality MG or CR for mammography for output 3 General studies and mammography studies are output in modality CR Operational limitations In the case of MG modality only the processed mammography images can be selected Unprocessed mammography images can be selected only when specifying Priva
5. Defined Terms CONTAINS HAS PROPERTIES HAS OBS CONTEXT HAS ACQ CONTEXT INFERRED FROM SELECTED FROM HAS CONCEPT MOD gt Include Document Relationship Macro TABLE 8 1 36 if the Target Content Item is included by value in the Source Content Item The Macro shall not be present if the relationship is by reference gt Include Document Content Macro TABLE 8 1 35 if the Target Content Item is included by value in the Source Content Item The Macro shall not be present if the relationship is by reference OTABLE 8 1 37 NUMERIC MESUREMENET MACRO ATTRIBUTES following contents have been added p ES Dicom Attribute Description Presence of Value This is the value of the Content Item ALWAYS AUTO Measured 0040 A300 Value Shall consist of a Sequence of Items Sequence conveying the measured value s which represent integers or real numbers and units of measurement Zero or one Item shall be included in this sequence gt Numeric 0040 A30A Numeric measurement value ALWAYS AUTO Value Only a single value shall be present gt Measurement 0040 08EA Units of measurement ALWAYS AUTO Units Code Only a single Item shall be included Sequence in this sequence ECN No 2012 E 0291Rev 1 78 78 o Dicom Attribute Description Presence of Value gt gt Code Value 0008 0100 Required if a sequence item is ALWAYS present gt gt Coding 0008 0102 1 Required if a sequence item is Scheme present Designator 0008 0
6. ECN No 2012 E 0291Rev 1 75 75 OTABLE 8 1 35 DOCUMENT CONTENT MACRO ATTRIBUTES following contents have been added pria Dicom Attribute Description Presence of Value Value Type 0040 A040 Concept Name Code Sequence 0040 A043 Text Value 0040 A160 The type of the value encoded in this ALWAYS AUTO Content Item Defined terms TEXT NUM CODE DATETIME UIDREF IMAGE CONTAINER Code describing the concept ALWAYS AUTO represented by this Content Item Also conveys the value of Document Title and section headings in documents Only a single Item shall be permitted in this sequence Required if Value Type 0040 A040 is TEXT NUM CODE DATETIME DATE TIME UIDREF or PNAME Required if Value Type 0040 A040 is CONTAINER and a heading is present or this is the Root Content Item Required if Value Type 0040 A040 is COMPOSITE IMAGE WAVEFORM SCOORD SCOORDSD or TCOORD and the Purpose of Reference is conveyed in the Concept Name This is the value of the Content Item ANAP Required if Value Type 0040 A040 is TEXT Text data which is unformatted and whose manner of display is implementation dependent AUTO The text value may contain spaces as well as multiple lines separated by either LF CR CR LF or LF CR but otherwise no format control characters such as horizontal or vertical tab and form feed shall be present even if permitted by the Value Representa
7. Usage Reterence Patient Patent FM Table 81 5 oe eee s a Study General Study OM Table 81 6 Patient Study Table 81 7 Cialis Cinical Trial Study u NotSuppored Serie General Sete m rableste CRSeies M frablesto Cinical Tial Series YU NotSuppored Equipment Generai Equipment m taes C Z zZ C M ECN No 2012 E 0291Rev 1 68 68 IE Module Usage Reference General Image Table 8 1 13 Image Pixel Table 8 1 14 Contrast bolus C Required if contrast media Table 8 1 15 was used in this image Not Supported CR Image M Table 8 1 17 X ray Tomo Acquisition Table 8 1 22 Overlay Plane C Required if graphic annotation is present BRERA U Table 8 1 26 Extended DX Positioning i Table 81 21 X ray Acquisition Dose P Table 8 1 23 X ray Generation Table 8 1 24 OTABLE 8 1 2 IOD OF CREATED DX IMAGE STORAGE SOP INSTANCES following contents have been changed PRINTED IN BLUE Module Usage Reference Table 8 1 5 Not Supported Not Supported Table 8 1 6 Table 8 1 7 Not Supported Table 8 1 8 Not Supported Table 8 1 10 Not Supported Table 8 1 12 Table 8 1 13 Table 8 1 14 Table 8 1 15 Not Supported Not Supported Not Supported Table 8 1 16 Table 8 1 18 Table 8 1 20 Not Supported Table 8 1 21 Table 8 1 22 Table 8 1 23 Table 8 1 24 Table 8 1 29 Not Supported Patient Patient Specimen Identification Clinical Trial Subject G x a Study eneral Study Patie
8. MPM code 091E has been selected Setup Configuration Item SYSTEM CONFIG 5 CSL IDT FUNCTION item354 MPM Code for QC lag Image new lt Procedure for acquiring unexposed images gt The procedure for acquiring unexposed images is as follows Click high sensitivity mode button to display the high sensitivity mode progress bar Leave it unexposed to make it timed out Default setting 30 seconds An unexposed image is acquired 4 4 Settings 4 4 1 Service Utility Settings Set up the following items in the Service Utility Setup Configuration Item SYSTEM a 15 CSL IDT FUNCTION 318 Use X ray Free Operation Arez Commenti X ray Yes Automatic Detection Operation function No sensitivity mode for DR cassette mi Time out Value in High Sensitive Mode 30 Time out value for the high The value range is 5 60 sensitivity mode sec 354 MPM Code for QC Lag Image 091E Console receives a blank image Multiple values can be input by _ after the time for the high separating them by commas sensitivity mode is over in the case of selected MPM code 4 4 2 User Utility Settings None 4 5 Effects on the other functions None 4 6 Cautions None ECN No 2012 E 0291Rev 1 30 39 ECN No 2012 E 0291Rev 1 31 39 5 Supporting CR mammography 5 1 Outline Mammography using CR cassette has become supported from V7 0 onward Console Advance supports the following functions Exposure and study menus for mammography an
9. Order information Distribution Setting No change in QA completed button on studies 20 1234567890 57Y 1955 MAY 05 fAccession Number te 2012 AUG 16 CHEST FRN P gt A 2 4 D 17 X17 PA No change in Study completed button on studies Pal Spacing 0 15mmi Focus Small M ignificatlion R sho 48 AF C Manual SLTA ESE mGy WIGS 10 02 mage Area Dose Product dGy cem cr fin his ER 9 m QA A 1012 AUG 16 fig os G hw lill Aces 2012 AUG 16 8 4 Settings 8 4 1 Service Utility Settings None 8 4 2 User Utility Settings None 8 5 Effects on the other functions None 8 6 Cautions None ECN No 2012 E 0291Rev 1 50 50 ECN No 2012 E 0291Rev 1 51 51 9 Storing worklist when retrieving MWM fails 9 1 Outline The worklist was cleared if the query failed when executing a query for the order to RIS C FIND RQ V7 0 however has enabled Console to retain the worklist before query without clearing it This modification improves the operatability on the RIS tab Note however that there is a risk of differences in the order information retrieved from the successful query and failed query to RIS under the condition where the clustering is being performed Careful attention is necessary when operating it under the clustering condition Confirmation of order information is required 9 2 Option key None Note however that DICOM MWM option key software is required to be installed as a precondition for operati
10. 14 Cannot be specified Gr og qa Cannot be specified 10454128 Cannot be specified 8 x 10 8 x 10 8 x 14 Cannot be specified 7 x 8 7 x8 7 x 10 7 x10 Saxo 5 x 8 18cm x 43m Cannot be specified P eine 0 04 Cannot be specified Kone ZTe sai Cannot be specified o Oo D O D i fn mf 3 3 5 DI N ECN No 2012 E 0291Rev 1 13 39 Note 1 The sizes that can be specified are selectable in the Service Utility IMAGE MODALITY item 317 Enable trimming Size1 IMAGE MODALITY item 318 Enable trimming Size2 2 Console Advance V7 0 cannot specify 24cm x 30cm trimming size Release the trimming setting when resizing the images acquired by 2430C to 24cm x 30cm 3 The images acquired by DR cassette cannot be trimmed to 18cm x 24cm in size 1 4 Settings 1 4 1 Service Utility Settings The additional device type items for registering the reader unit in the Service Utility are as follows Set up the device type for 2430Csl Device Setting Add Modify Device Type CALNEO C mini D EVO plus C24 Select it in the case of 2430Csl CALNEO HC SQ Select it in the case of HandyModule Applicable only in Japan Select CALNEO C mini D EVO plus C24 from the Device Type list Device Mame A FFO Device ID Device Type CALNEO LMT ME CALNEO C FDA D EVO CALMEO C SQ FDR D EVO plus Uh acs eerste CALNEO C mini D E O plus C24 Note Set up the following it
11. 2 Select Product Select the type of previous Console prior to the upgrade CR Console Enter 1 Skip to step 8 to confirm the image processing parameter for converting film to monitor Console Advance Enter 2 Terminating the tool Enter 0 3 Add Mammography Menu Add mammography menu Adding the menu Enter y Not adding the menu Enter n Add Tomosynthesis Menu Add tomosynthesis menu Adding the menu Enter y Not adding the menu Enter n 5 Select Language Select the language displayed only when menus are added in step 3 or 4 Japanese Enter 1 English U S Enter 2 Other than above including English excepting U S Enter 3 6 Select Parameter Type Select the parameter type for image processing for film or for monitor displayed only when menus are added in step 3 or 4 For film Enter 1 For monitor Enter 2 7 Select Xcon Parameter Type Select XconParam mdb according to XCON parameter type displayed only when menus are added in step 3 or 4 Be sure to select 1 for CR even though the options are displayed For CR Enter 1 For GOS Enter 2 For aSe Enter 3 For Csl Enter 4 N Caution Do not select 2 for GOS 3 for a Se 4 for Csl even though they are displayed The values of exposure conditions are not guaranteed when GOS a Se Csl is se
12. English US 6 All Monitor Selected from the other For the other regions Ordinary luminance ECN No 2012 E 0291Rev 1 languages languages Monitor GT t other than Film condition is converted Japanese to lower case character and English US E Limitations Storage output in Non normalized cannot be performed if Film is selected 5 4 4 Registration of implant information W Images of the registration windows lt Registration window gt Patient s Name Patient ID Sex Birth Date ex FEB Outpatent inpatient Requesting Department Others Contrast Allergies Patient comments Study comments With or without an implant lt User Utility Patient information maintenance window gt Enter patient s information Patent ID Patient s Name Contrast Allergies Se Sex o J _ Birth Date a 1975 FEB 25 Fatant comments Implant Information Cancel at E Enabling the functionality Set up the following items to Yes Setup Configuration Item SYSTEM CONFIG 1 IMAGE MODALITY ECN No 2012 E 0291Rev 1 36 39 Area Default value 349 Enable Implant Input Yes Presence or absence of implant No information WE DICOM Tag definition Implant information is attached to the image in DICOM Storage for output 0028 1300 Whether or not an implant is present 0054 0220 gt 0054 0222 View Modifier for Mammography 5 4 5 Registration of View Code View Modifier code The
13. Media Storage function for DVD media if necessary V7 0 includes the countermeasures which have been provided in HF4000 Base V4 0 ECN 2012 E 0106 against the errors occur in the media storage Subject Contents of countermeasures Write error occurs in the media storage The countermeasures which are equivalent to CR IR355CL have been taken Variable remaining capacity when writing Automatic ejection when unmounting ECN No 2012 E 0291Rev 1 7 39 Variable waiting time when ejecting Variable waiting time when terminating In addition the media file lock is released before ejection The following parameters can be changed Change them if necessary Waiting time for terminating the application sec managed in the setup file File name C Program Files FujiFilm lIP System MediaStorage exe config Tag lt configuration gt lt appSettings gt lt add key ProcessEndMarginTime value 3 gt lt appSettings gt lt configuration gt Upper limit 20 Lower limit 1 Default ae Edit XML file manually if necessary Remaining capacity MB managed in registry Key HKEY LOCAL MACHINE SOFTWARE F yjiFilm IIP Media MediaVolumeLimit Type REG DWORD Upper limit 2100 Lower limit 21 default This key has already been existed As the key used only the registry value it has been changed to check the upper and lower limit Waiting time for ejecting sec managed in registry Key HKEY LOCAL MACHINE SO
14. Required if the date and time are different from the Content Date 0008 0023 and Content Time 0008 0033 or the Observation DateTime 0040 A032 defined in higher items May be present otherwise Note When Content Items are copied into successor reports the Content Date 0008 0023 and Content Time 0008 0033 of the new report are likely to be different than the date and time of the original observation Therefore this attribute may need to be included in any copied Content ltems to satisfy the condition aa ae ee i sisi i il EON No 2012 E 0291Rev 1 77 77 se Dicom Attribute Description Presence of Value Attibute tag type Dicom Attribute Description Presence of Value Source 0040 A010 A potentially recursively nested ALWAYS AUTO Sequence of Items that conveys content that is the Target of Relationships with the enclosing Source Content Item One or more Items shall be included in this sequence Required if the enclosing Content Item has relationships Notes 1 If this Attribute is not present then the enclosing Item is a leaf 2 The order of Items within this Sequence is semantically significant for presentation gt Relationship 0040 A010 The type of relationship between the ALWAYS AUTO Type enclosing Source Content Item and VALUE is HAS the Target Content Item CONCEPT MOD or IODs specify additional constraints CONTAINS on Relationships including lists of Enumerated Values
15. Select Internet Protocol Version4 TCP IPv4 and then click Properties Local Area Connection 2 Properties x Connect using i Intel R Gigabit CT Desktop Adapter Configure This connection uses the following items 0 Client for Microsoft Networks 2 QoS Packet Scheduler File and Printer Sharing for Microsoft Networks i Intemet Protocol Version 6 TCP IPv BS Intemet Protocol Version 4 TCP Pv4 SI i Link Layer Topology Discovery Mapper 1 0 Driver i Link Layer Topology Discovery Responder Descrinti wide area network protocol that provides communication across diverse interconnected networks 5 Select Use the following address and set up the following IP address 192 168 0 10 Subnet mask 255 255 255 0 Others Blank Do not enter values Input values are examples Internet Protocol Version 4 TCP IPv4 Properties General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use the following IP address IP address 192 168 0 10 Subnet mask p55 255 255 0 7 Obtain DNS server address automatically 6 Click OK to close the window ECN No 2012 E 0291Rev 1 24 39 Setting priority of network bindings Set up the priority of network bindings in the following order 1 on board in
16. Software 114Y2150201B00 is required 6 3 Details Tomosynthesis view Reconstruction condition setup The labeling of items has been revised and icons for each item and the indicator of image reconstruction condition have been added V6 2 THORACIC SPINE FRN TMS Slice height mm Direction reconstruction Output Range 30 Ft ZE Cancel a pF Slice range mm Reconstruction mode 60 st FBP1 Slice spacing mm 2 V7 0 THORACIC SPINE FPN TMS e a CF Center mm Direction cancel Output Range 100 st Range mm Mode 60 j Fer isa Pitch mm 2 ils ECN No 2012 E 0291Rev 1 44 44 JExposure condition setting dialog for tomosynthesis The labeling of items has been revised and icons for each item have been added V6 2 Exposure condition Reconstruction condition Exposure Distance SID cm Height of the center slice mm 100 50 _ Ft X ray tube tomo angle Slice range m m O 50 0 40 30 cla Total exposure time Spacing of the slices mm Slice direction te construction mode SA V7 0 Exposure condition Reconstruction condition Exposure Distance SID cm Center mm 100 X ray tube tomo angle 0 Total exposure time s T2 100 Range mm 60 Pitch mm Direction ECN No 2012 E 0291Rev 1 45 45 6 4 Settings 6 4 1 Service Utility Settings Set up the following items in the Service Ut
17. V7 0 can be performed only from the following versions DR ID 300CL V5 0 HF included DR ID 300CL V6 0 HF included DR ID 300CL V6 1 HF included DR ID 300CL V6 2 HF included When transferring data from the following versions transfer them to V5 0 first and then upgrade to V7 0 DR ID 300CL V4 0 HF included CR IR 348CL V8 0 V8 1 V8 2 V8 3 HF included Note 2 When upgrading the mis exposure image log exposure result log will be deleted When upgrading at the institutions where the users are using the exposure result data file output function or the mis exposed image comment function collect the logs by using the log storage function of the User Utility before upgrading Refer to step 3 of 4 2 Upgrading Installation Note 3 When upgrading the precise enlargement function the overlay items will not be migrated Therefore evacuate the user setting files before upgrading and restore them after the upgrade Note 4 Subsequently to the version upgrade be sure to execute CopyReserveCode1FromMicroAs bat on the systems where a temporary countermeasure setting the data of the previously configured ReserveCode1 to the first four digits of Exposure_UAs has been implemented against an error which makes the communication value field for anatomical connection with Toshiba X CON different from the one used in V4 Refer to step 24 of 4 2 Upgrading Installation The data of the first four digit
18. be supported by V7 1 Bi Caution Mixed connection of general X ray system and mammography X ray system is prohibited Establish the connection to either system 5 5 Settings 5 5 1 Service Utility Settings WE Set up the following configuration items in the Service Utility to enable the functionalities sere ce ae Item SYSTEM CONFIG 1 IMAGE MODALITY Area Default value Modality Setup 0 MG Specifying modality for study Mammography Image 2 LE exclusively for mammography i I a OR u information Refer to 5 4 1 Mammography study above for the procedures to set up No 35 Modality Setup for Mammography Image and No 54 Modality Setup Setup Configuration Item SYSTEM CONFIG 3 QA FUNCTION Pem Processing in the case of Yes Specifying whether or not to perform Magnify Display PEM processing on and ultra high density image when it is magnified and displayed for CR only POE Configuration Item SYSTEM SOLI Mammography mm mm for mammography Print Image Frame 2636 E whether or not to add image film 18x24 elet frame to 18x24cm or 24x30cm size film 18x24 Single Mammography images that are printed on 26x36cm Format size film in the single mammography format or to 18x24cm size images that are printed on 8 x10 size film in the single mammography format Print Image Frame Yes Specifying whether or not to add image 2636film 18x24 20n1 100 No frame when printing
19. disconnection etc under the condition of small time out value for the PPS connection To prevent this phenomenon set up DICOM PSS as follows In the setting of DICOM PPS within a local Console Service Class Modality Performed Procedure Step Role SCU set the time out value to a default value 15 or greater 5 8 Caution DX Image Storage For Processing prohibited The device Synapse to connected to has not been supported although the support of the DI COM Digital X ray Image Storage For Processing has been notified in the ECN No 2011 E 0290Rev 1 software information of V6 0 Therefore do not set up DICOM Digital X ray Image Storage For Processing 5 9 Caution no device to output shuttering setting with the file attribute Although V5 0 was equipped with a function to output the shuttering processing area as supplementary ECN No 2012 E 0291Rev 1 9 39 information no device can use the information so far Therefore be sure to set Apply mask processing to the image to the setup item of Mask Processing in the registration of the other device settings of DICOM SCP on Console in V5 0 or later 5 10 Setting for marking stitched portions when making stitched images Set up the following to mark the stitched portions on images Setup Configuration Item SYSTEM CONFIG 1 IMAGE MODALITY 70 Enable Marking Stitched Image Select Yes 5 11 Cautions at the time of new system installation The icon for the selector to
20. hospital network 2 extended NIC local network for image transfer 1 Open the Control Panel from the Start menu 2 Open Network and Sharing Center and then click Change adapter setting 2101 x ont N xx E g yy Ri All Control Panel Items Network and Sharing Center al Search Control Panel 2 i Control Panel Home View your basic network information and set up connections gt See full map Change adapter settings A x K J Change advanced sharing settings DA26726851 Unidentified network lent This computer View your active networks Connect or disconnect TE Access type No Internet access nidentified network f ni Public network Connections ci Local Area Connection W Local Area Connection 2 Change your networking settings de Set up a new connection or network lt Set up a wireless broadband dial up ad hoc or VPN connection or set up a router or access point y Connect to a network Connect or reconnect to a wireless wired dial up or VPN network connection ip Choose homegroup and sharing options Access files and printers located on other network computers or change sharing settings amp a Troubleshoot problems Diagnose and repair network problems or get troubleshooting information See also HomeGroup Internet Options Windows Firewall 3 Select Advanced Settings from Advanced menu If the menu bar is not displayed press lt Alt gt key to dis
21. processing MPM Code Related Menu L MAMMOGRAPHY CC 0349 R MAMMOGRAPHY CC FCR Image processing parameter for CR exposure is being determin 5 4 3 Newly installed menus The following menus are installed when installing the menu data from the application DVD Installation procedure 1 Start up the application DVD 2 Select 3 Install Parameter Files 3 Select the language 4 Select Monitor or Film for Parameter Type 5 Select CR for XCon Parameter Type The selections of language and parameter type specify the settings See the following table Language Parameter Three menu DBs to be Image processing parameters Supplemental information of the type installed to be installed parameter MenuData mdb for general studies DisplayData mdb for mammography XConParam mdb for mammoQC for general studies AII of the above is installed for mammography for mammoQC All of the above is installed 1 Japanese Film For Japan For Japan Film High luminance GT W Japanese Monitor For Japan For Japan Monitor Ordinary luminance GT w Film condition is converted to lower case character bll English US For For USA Film FDA PMA condition GT T English US Monitor For _ For USA Monitor FDA PMA condition GT t Film condition is converted to lower case character Selected from the other For the other regions Film Ordinary luminance ca languages other than Japanese and
22. set up will be the one for 1M 2M ST_NonTubeCRC png if StandardKIT Mobile has been used In this case change it to the icon file for 0 7M ST_NonTubeCRC_S png in the Service Utility Comparing to DELL PCs HP PCs make bigger sound when registering IPs Attach external speakers only when they are necessary 5 12 Troubleshooting the freeze occurring when Console is left untouched for a certain length of time A phenomenon has been reported from the market Console freezes when it is left alone for a certain length of time after it is used Refer to ECN 2012 E 0229 for details of the troubleshooting procedure that has been released 5 13 Settings for using DX Storage for general studies other then Mammography studies DXV7 0 enables settings under 1 IMAGE MODALITY 35 Modality Setup for Mammography Image in the Service Utility Select 2 MG in 35 Modality Setup for Mammography Image when using DX Storage if 0 DX is selected in 54 Modality Setup General study Mammography a Setup R Setup for other than x3xx study x3xx System setup Prohibited 5 14 Disabling Mammography function for US only Disable the mammography function in the US until 510k clearances are granted Refer to 1 2 Disabling Mammography function for US only in Appendix A_Functional Settings for details of the procedure ECN No 2012 E 0291Rev 1 10 39 5 15 Caution about displayed message MD3009 If Console operation is c
23. specified as automatic markers are required to be located under the MarkerBmp folder The study cannot be performed if the specified marker file does not exist in the folder where the exposure menu with automatic marker settings has been selected and image input is being executed in the background 5 5 2 2 At the time of software version upgrade In the case of version upgrade the marker files for mammography are not automatically copied but exist in the installer DVD lt The storage location of the marker files for mammography gt Installer DVD program files FujiFilm IIP MarkerBmp_ def Japanese bmp Other bmp 1 Select the bitmap to be used from the bitmap folder for mammography Installer DVD program files FujiFilm IIP MarkerBmp_def Japanese Other bmp Copy the necessary markers Note that 128 is the maximum number C Program files FujiFilm IIP MarkerBmp bmp lt Caution gt Do not delete the automatic markers used for general X ray system If they are deleted image input errors will occur 2 Perform the display setting Execute the following batch file to create RegMarkerBmp csv file Installer DVD tools CreateMarkerCSV bat RegMarkerBmp csv file is created updated 3 Change the display order of the marker files The marker files are displayed in the order they are written in the following file Change the order manually if necessary C Program files FujiFilm IIP MarkerBmp RegMarkerBm
24. the users who have been using full range processing since V5 0 and monitor diagnosis Because the installer does not add the menus nor change the image processing parameters described above it is require for service personnel to add the menus by using the MenulmportExportTool and modify the image processing parameters manually It is expected that the word takes time and labor to complete them This tool supports the following operations when upgrading the application software from the old edition to V7 0 or later Addition of menus for tomosinthesys nammography and modification of the image processing parameters according to the additional menus Converting image processing parameters from film to monitor This tool can be used when upgrading application software version or performing system transition This tool can be used exclusively by service personnel Do not allow users to use this tool Applicable version V7 0 or later Note that there are limitations according to the original versions Console film to monitor Console V8 x Version upgrade from Applicable Applicable Applicable Console Advance V5 0 to Exposure menu image Exposure menu image V6 2 processing parameter processing parameter information information The menus and image processing parameters used in the existing CR Console will be lost 1 2 Requirements System requirements The system requirements for this tool are as follows OS Microsoft Windows
25. to the language setting to add the menu in the proper language while being executed Caution This tool may not run properly if the preparation above has not been performed 3 2 Activation of the tool Insert the installer media for V7 0 or later into Console Advance that has been upgraded to V7 0 or later and double click the following file root tools ExtendedParamConvertTool ExtendedParamConvertTool bat The following window starts up C Windows system32 cmd exe Select Number ECN No 3 3 Operational procedure The operational flow is as follows 2012 E 0291Rev 1 Operation flow p 1 Executing the batch file Console Advance 2 Select Product 3 Add Mammography Menu Select Yes No 4 Add Tomosynthesis Menu 7 Select Yes No es has been selectes either in 3 or 4 above 5 Select Language Select 1 Japanese 2 USA 3 Other 6 Select Parameter Type Select 1 Film 2 Monitor 7 Select Xcon Parameter Type Select 1 CR 2 GOS 3 aSE 4 Csl 8 Film to Monitor Conversion Select Yes No J Was selected OO Do ou want to implement 10 Do you want to apply the Yes Completion message Process was successfully finished appears O Complete Pale blue the items the user selects the options on the command prompt 56 56 ECN No 2012 E 0291Rev 1 57 57 lt Operational procedure gt 1 Start up the tool
26. 0 or later may have been failed Confirm if the upgrade has been completed properly ECN No 2012 E 0291Rev 1 61 61 7 Additional menu list 7 1 Menus for the regions other than the US 7 1 1 Mammopraphy menu 1 Exposure menu FCR0307 0000 BREAST L DSR WW FCR7302 0008 ECN No 2012 E 0291Rev 1 62 62 2 Study menu FCR7300 07 1Shot ACR 7 1 2 Tomosynthesis menu 1 Exposure menu FCR7000 0004_ PARANASAL SINUS FRN TMS___ FCR7501 0000___ PELVIS TMS FCR72030000 THORACIC SPINE FRNTMS____ FCR7601 0003_ HAND FRN TWIS 2 Study menu None ECN No 2012 E 0291Rev 1 63 63 7 2 Menus for the US 7 2 1 Mammography menu 1 Exposure menu Extended Menu Code ANK Exposure Menu Name Extended Menu Code ANK Exposure Menu Name FCR0308 0001 FCR0328 0000 FCR0328 0001 FcRo338 0001 RxCCL_ FCR73020039 _ Mode8 CNR PMMASOmm FCR0348 0000 Mode8 CNR PMMA70mm FCR7301 000 FOR7302 0008 FCR7302 0011 Mode1 CNR PMMA60mm FCR7313 0005 Uniform Expo 1 Ghost FCR7302 0012 Mode1 CNR PMMA70mm FCR7313 0006 ACR Phantom2 Ghost FCR7302 0018_ Mode CNR PMMA40mm _ FCR7325 0003 ACR Phantom ACR Phantom Mode6 CNR PMMA40mm ECN No 2012 E 0291Rev 1 64 64 2 Study menu 7 2 2 Tomosynthesis menu 1 Exposure menu FCR72030000 THORACIC SPINE FRNTMS____FCR7601 0003__ HAND FRN TWS 2 Study menu None ECN No 2012 E 0291Rev 1 65 65 DR ID 300CL V7 0 ECN Appendix C List of Changes in System
27. 1 CSL C localhost name resolution is Aa wi zi 27 0 0 1 fi 172 16 2 80 CSL 172 16 2 81 CSL B ele ali lea 7 Pressing the exposure button and the study completed button simultaneously may disable image input causing an image loss where VELOCITY is connected 1 Do not press the exposure button and click the study completed button simultaneously 2 Restart VELOCITY if the phenomenon of no image input occurs in this case The menus on Console does not reflect the changes in the reference position of trimming made on the tube monitor of FDR AcSelerate CALNEO U when setting 10 x14 trimming Be sure to change reference position of menus on Console Note This phenomenon does not occur when VELOCITY is connected Do not use the grid density gradient reduction function portable exposure alignment detection on V7 0 Option Key Grid Shading Reduction Key Software V1 0 114Y2150133B00 e Console freezes at the time of image input which requires a forced termination Do not acquire images if a message of image reacquision appears Console freezes at the time of image input Note This limitation will be removed on V7 1 7 List of attachments Functional Settings Appendix A Extended parameter convert tool Appendix B List of Changes in SYSTEM CONFIG Appendix C List of Changes in Conformance Statement Appendix D ECN No 2012 E 0291Rev 1 12 39 DR ID 300CL V7 0 ECN Appendix A Functional Settin
28. 103 1C Required if a sequence item is present Required if the value of Coding Scheme Designator 0008 0102 is not sufficient to identify the Code Value 0008 0100 unambiguously gt gt Code 0008 0104 1 Required if a sequence item is ALWAYS Meaning present OTABLE 8 1 38 CODE MACRO ATTRIBUTES following contents have been added ee Dicom Attribute Description Presence of Value Concept Code 0040 A168 1 This is the value of the Content Item ALWAYS Sequence Only a single Item shall be included in this sequence gt Code Value 0008 0100 1 Required if a sequence item is ALWAYS present gt Coding 0008 0102 1 Required if a sequence item is Scheme present Designator 0008 0103 1C Required if a sequence item is present Required if the value of Coding Scheme Designator 0008 0102 is not sufficient to identify the Code Value 0008 0100 unambiguously gt Code 0008 0104 1 Required if a sequence item is ALWAYS Meaning present OTABLE 8 1 39 IMAGE REFERENCE MACRO ATTRIBUTES following contents have been added per Dicom Attribute Description Presence of Value Referenced 0008 1199 1 References to Composite Object ALWAYS SOP Class SOP Instance pairs Only a single Item shall be included in this Sequence gt Referenced 0008 1150 1 Uniquely identifies the referenced SOP Class SOP Class UID gt Referenced 0008 1155 1 Uniquely identifies the referenced SOP Instance SOP Instance UID EC
29. 2012 E 0291Rev 1 48 48 8 Improvement in QA termination button 8 1 Outline The design of the QA completed button which closes QA window has been modified to differentiate it from QA determined button 8 2 Option key None 8 3 Details The following button has been changed QA completed button on the study list which closes the window to return to the study list window To distinguish it from QA determined button the design has been changes to represent closing QA window to return to the study list V6 2 or earlier Complete There is no change in the following buttons QA completed button on studies which closes the window to return to the study window QA determined button on QA window of the study list lt QA completed button on the study list Which closes the window to return to the study list gt No change in QA determined button aZ FUJI TAROU M 123457890 0 Y 57Y 1955 MAY 05 Marker Image rotation reversal Trimming Image Processing i Order information Distribution Setting This button has been changed on V7 0 The window returns to Pwal aang 0 15mm Maq icabon Pato 4a the study list It is not the QA AwQQaats determined button ECN No 2012 E 0291Rev 1 49 49 lt QA completed button on studies which closes the window to return to the study window gt FUJI TAROU M 123457890 57Y 1955 MAY 05 Marker image rotation reversal Trimming image Processing
30. CN No 2012 E 0291Rev 1 40 40 Japanese bmp Other bmp Either Japanese or other languages default contents are identified for set up according to the language setting in OS in the installer However there are three types of definitions to connect the automatic marker and exposure menu for Japanese for other languages and for the US If it is set to for the US select 2 English U S in the installer menu 3 Install Parameter Files to install the definitions of automatic marker file connections for the US The marker files to be connected at this time are included in the other languages Marker Other folder 1 Rename the folder in which the marker files for general X ray system are stored C Program files FujiFilm IIP MarkerBmp Rename the folder C Program files FujiFilm IIP MarkerBmp_bak 2 Copy and rename the folder for mammography C Program files FujiFilm IIP MarkerBmp_bak Japanese Other l Copy the folder according to Japanese Other environment and rename it C Program files FujiFilm IIP MarkerBmp 3 Perform the display setting Execute the following batch file to create RegMarkerBmp csv file Installer DVD tools CreateMarkerCSV bat RegMarkerBmp csv file is created updated 4 Change the display order of the marker files The marker files are displayed in the order they are written in the following file Change the order manually if necessary C Program files FujiFilm IIP MarkerBm
31. Config The following items have been added 1 IMAGE MODALITY Name 35 Modality Setup for Mammography 0 MG Specifying modality for study exclusively for Image 2 CR mammography 342 Image File Type For Types of image to display on the Tomosynthesis Viewer tomosysthesis viewer 0 image reduced 1 2 in size 1 image with normal density Enable Implant Input Presence or absence of implant information No Display Pixel Size for 2nd monitor 264 Display pixel size 0 001mm for the 2 1 monitor 3 QA FUNCTION No Name C C C_ Area Default value 19 Pem Processing in the case of Specifying whether or not to perform PEM Magnify Display processing on and ultra high density image when it is magnified and displayed for CR only 22 Enable Adjust GA GS by dragging ia Enabling Disabling GA GS adjustment by dragging mouse 23 Response GA 0 a 18 Making smaller GA sensitivity value more sensitive when performing GA GS adjustment by dragging mouse 24 Response GS 0 99 18 Making smaller GS sensitivity value more sensitive when performing GA GS adjustment by dragging mouse 4 PRINTER Name Area Default value Trimming Range for 0 cene the amount of trimming in mm for Mammography mm mammography 27 Print Image Frame 2636 Yes Specifying whether or not to add image film 18x24 th ea film 18x24 No frame to 18x24cm or 24x30cm size images Single Mammography Format that are printe
32. Control Panel from the Start menu 2 Open Network and Sharing Center to click Local Area Connection 2 on Network and Sharing Center Oj x go FS All Control Panel Items Network and Sharing Center X l Search Control Panel n Control Panel Home View your basic network information and set up connections gt See full map Change adapter settings A T x Le J Change advanced sharing settings DA26726851 Unidentified network Internet This computer View your active networks Connect or disconnect Access type No Internet access E Usidentiied neiwork Connections Local Area Connection ee Change your networking settings ile Set up a new connection or network Set up a wireless broadband dial up ad hoc or VPN connection or set up a router or access point A Connect to a network Connect or reconnect to a wireless wired dial up or VPN network connection wd Choose homegroup and sharing options Access files and printers located on other network computers or change sharing settings Troubleshoot problems l Diagnose and repair network problems or get troubleshooting information See also HomeGroup Internet Options Windows Firewall 3 Click Properties li Local Area Connection 2 Status x IPv4 Connectivity No Internet access IPv6 Connectivity No Internet access Media State Enabled Duration 00 07 01 Speed 10 0 Mbps ECN No 2012 E 0291Rev 1 23 39 4
33. Details Mi Integrated MC configuration Vv Configuration example1 Single MC configuration Install MC application software in Console Advance Console Advance receives images from DR cassette reading unit In hospital network SS Main CSL MC reader unit Clustering The applicable scope of this configuration is as follows D EVO VELOCITY PRELIO FCR Cassette Image Reader Reference DR ID700 will be connected after it enables to support this configuration ECN No 2012 E 0291Rev 1 16 39 Vv Configuration example 2 the configuration combined with CU Console Advance receives images from DR cassette reader unit Console Advance receives images of DR system from CU In hospital network Main CSL MC FCR image reader unit Fella xs Clustering DR exposure stand The applicable scope of this configuration is as follows CALNEO U M D EVO VELOCITY PRELIO FCR Cassette Image Reader Connection with DR ID700 is not supported WE Hardware requirement of integrated MC configuration The integrated MC configuration requires following hardware Memory expanded from the system running on V6 2 or earlier 2GB 4GB Expand the memory to 4GB in the case of standard PC Memory expansion is not required if the integrated MC is not installed in Console Advance For desktop PC Specification Extended network card two LAN ports are necessary the on board network card co
34. ECN No 2012 E 0291Rev 1 FUJIFILM ENGINEERING CHANGE NOTICE FIELD CHANGE NOTICE SUBJECT Rev 1 Releasing the information of DR 1D300CL Application Software V7 0 Design Change Reason Action Dx Product Improvement 1 _ Mandatory _ Immediately _ Process Improvement gt lt Recommended 2 by _ Serviceability L Upon failure gt lt Next maintenance 2 _ Part Replacement gt lt Not required Information only 1 L At your convenience gt lt Corrective Action 2 L Other Dx NA 1 _ Preventive Action Regulatory Compliance _ Other 1 corresponds to the New Function Enhancement below whereas 2 to the Error Corrections DATE Oct 4 2012 Dept Quality Assurance Div Medical Systems R amp D Center ORIGINATOR _T Saito EDITED BY _A Takahashi APPROVED BY _T Uekusa AFFECTED PRODUCTS _DR ID300CL TOTAL PAGE S __ 82 ATTACHMENT X YES LINO RELATED INFORMATION _ None kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk CL Application V7 0 for DR ID300CL including new functions and error corrections is ready to be released New Functions Enhancement 1 2430C connection 2 Integrated MC 3 Supporting high sensitivity mode of automatic X ray detector 4 Supporting CR mammography 5 Enabling GA GS adjustment using mouse Error Corrections 1 Studies are not deleted from the list even after th
35. ELL PC 10 Insert the Option NIC Board Driver CD 114Y2150764B00 into DVD drive 11 Open the Control Panel from the Start menu 12 Select the items as follows Control Panel ECN No 2012 E 0291Rev 1 19 39 Device Manager Network adapter 13 Select the extended NIC and right click it to select Update Driver Software A Device Manager File Action View Help e m E H ble eo Eg DA26726851 E Mil Computer E io Disk drives i amp Display adapters B DVD CD ROM drives 43 Human Interface Devices gg IDE ATA ATAPI controllers Keyboards JA Mice and other pointing devices Ma Monitors gt Network adapters E Ports Com aLPT Update Driver Software gr Processors Disable Ee Security Devices Uninstall Fa Sound video and game controller Hj System devices Scan for hardware changes H Universal Serial Bus controllers Properties 14 Select Browse my computer for driver software Update Driver Software Intel R Gigabit CT Desktop Adapter l x ai K J Update Driver Software Intel R Gigabit CT Desktop Adapter How do you want to search for driver software gt Search automatically for updated driver software Windows will search your computer and the Internet for the latest driver software for your device unless you ve disabled this feature in your device installation settings gt Browse my computer for driver software Locate and install driver so
36. FTWARE FyjiFilm lIIP Media EjectMarginTime Type REG DWORD Upper limit None Lower limit 3 Default value without key The key is not generated when CL Application is being installed Set it up if necessary 4 7 Confirming the installation 1 Restart the PC and confirm that Console application starts up without errors ECN No 2012 E 0291Rev 1 8 39 5 Cautions 5 1 Caution error when using SynapseWebQuery on upgraded Console The message GetPixels failed with error CDicomlmgSrc GetPixels Failed to process image may appear and it disables image reference function when using SynapseWebQuery where the Console application software has been upgraded from the old version the latest version In this case reinstall the SYNAPSE client application 5 2 Caution operation prohibited during RAID reconstruction Do not use Console while RAID reconstruction is in process Console may not work properly 5 3 Caution shot switch disabled when connection to D EVO is established When the shot SW1 is turned ON OFF while the connection to D EVO is being established the shot may not be performed even when the Ready is lit In this case select the menu again and continue the operation 5 4 Caution wrong image orientation after reading study data output to media in non FUJI original format The orientations of the images might be changed when reloading image data that was output to media without the Fuji original SOP Classes and then making s
37. ICOM definitions as has been so previously 1 XCON Conforms to the XCON I F definitions of 2on1 Mammography Format Setup Configuration Item SYSTEM CONFIG 5 CSL IDT FUNCTION 42 Wait Time for Performed 0 to 30 0 Specifying the wait time in seconds Exposure Info From Xcon between the instant at which the ID information acquisition request is received from the built in type machine and the instant at which the XCON exposure result information is received in situations where exposures are made by the built in type machine with the XCON connection established XCON Image display caption when the XCON Use a maximum of five is connected alphanumerics to specify 4 Xcon Status Display Strings the caption 3 44 Xcon Serial_TX Control Port 0 to 3 0 Performing XCON control serial port setup 45 Xcon Performed Info Reception Yes Specifying whether or not to receive No operating condition data 46 Xcon Exposure Info Transfer Yes Specifying whether or not to transfer No exposure condition data 47 Xcon Exposure Info Limit Value 0 to 9999 20 Minimum tube voltage Minimum KVP kV 48 Xcon Exposure Info Limit Value 0 to 9999 150 Maximum tube voltage Maximum KVP kV 49 Xcon Exposure Info Limit Value 0 to 9999 9 Minimum tube current Minimum X ray Tube Current MA 50 Xcon Exposure Info Limit Value 0 to 9999 1250 Maximum tube current gt area eee ee
38. N No 2012 E 0291Rev 1 79 79 OTABLE 8 1 40 CONTAINER MACRO ATTRIBUTES following contents were added ee Dicom Attribute Description Presence of Value Continuity of 0040 A050 1 This flag specifies for a CONTAINER ALWAYS Content whether or not its contained Content VALUE is Items are logically linked in a SEPARATE continuous textual flow or are separate items Enumerated Values SEPARATE CONTINUOUS 0040 A504 1C Template that describes the content ALWAYS of this Content Item and its subsidiary Content Items Only a single Item shall be included in this sequence Required if a template was used to define the content of this Item and the template consists of a single CONTAINER with nested content and it is the outermost invocation of a set of nested templates that start with the same CONTAINER gt Mapping 0008 0105 1 Mapping Resource that defines the ALWAYS Resource template See Section 8 4 Defined Terms DCMR DICOM Content Mapping Resource gt Template 0040 DB00 1 Template identifier Identifier OTABLE 8 1 43 IRRADIATION EVENT X RAY DATA following content has been added Parent Value EV 113735 DCM Units EV ms CUM ms Exposure Time OTABLE 8 2 1 DATA DICTIONARY OF PRIVATE ATTRIBUTES following content has been added attributeName Tag ve wm Notes OTABLE 8 5 1 IOD OF CREATED PRIVATE CR IMAGE STORAGE SOP INSTANCES following contents have been changed PRINTED IN BLUE
39. Processingll taz parameter l parameter 1 SHARPd prm Image processing parameter 16 ESd prm Image processing parameter Q gt K O1 17 C Program Select prm Image processing parameter Files FujiFilm lIIP lmageProcessing mageProc System DR InDirF PD GO S 18 C Program Select prm Image processing Files FujiFilm IIP lmageProcessingl l parameter mageProc System DR InDirFPD Csl 19 C Program Select prm Image processing Files FujiFilm IIP lmageProcessingl l parameter mageProc System DR DirFPD a Se 20 C Program Gdu prm Image processing Fiimn monitor Files FujiFilm lIP lmageProcessing l parameter mageProc System CR Default User RNR 21 C Program Gdu prm Image processing sisma Files FujiFilm lIP lmageProcessing parameter mageProc System DR Default User PNT 6 Handling errors Windows error messages appear when the tool malfunctions Correct errors as the messages indicate Note however that the error messages in the following table appear when errors occur while adding menus to MenuData mdb XconParam mdb The error messages and procedures for correcting them are as follows Correct the errors according to the Windows message or the procedures described in the table below when errors occur during step 1 to 9 in 3 3 Operational procedure above Then restart the tool and perform the steps from the beginning ECN No 2012 E 0291Rev 1 60 60 In the case of errors occur in step 10 in 3 3 Operation
40. Settings None 3 5 Effects on the other functions None 3 6 Cautions Refer to the Operation Manual of the panel for details of making high sensitivity exposure and cautions ECN No 2012 E 0291Rev 1 29 39 4 Image acquisition without exposure under the condition where automatic X ray detector activated 4 1 Outline lt Supporting image acquisition without exposure gt Image acquisition without making exposures is required for measuring erasing performance of image detector DR cassette etc on general reader unit QC On V6 0 image acquisition cannot be initiated unless X ray is detected under the condition where the automatic X ray detector is activated V7 0 has enabled image acquision without making exposures 4 2 Option key None 4 3 Details MC transmits an unexposed image to Console automatically in the case of DR cassette and the menu for unexposed QC lag image acquisition Default MPM code 091E lt Precondition for connected DR cassette gt The connected DR cassette supports this function MC V4 0 or later lt Conditions for acquiring unexposed images gt The function is enabled in case the following conditions are satisfied Using DR reader unit that supports automatic X ray detector function Configuration has been set up for enabling high sensitivity mode refer to 3 Supporting high sensitivity mode of automatic X ray detector above for details The menu for unexposed QC lag image acquisition
41. VISTA Business SP1or SP2 Microsoft Windows 7 Professional or SP1 Console 1 The Console that has been upgraded from CR IR 348CL V8 0 including HF CR IR 348CL V8 1 including HF CR IR 348CL V8 2 including HF CR IR 348CL V8 3 including HF to DR ID300CL V7 0 or later 2 DR ID300CL that has been upgraded from V5 0 including HF V6 0 including HF V6 1 including HF V6 2 including HF to V7 0 or later 2 Setup procedure This tool does not require any setup such as installation Double clicking the following file which is stored in the installer media for V7 0 onward starts up the tool Refer to 3 Operational procedure and confirm the contents before using the tool root tools ExtendedParamConvertTool ExtendedParamConvertTool bat 3 ECN No 2012 E 0291Rev 1 55 55 Operational procedure 3 1 Preparation Perform the following before starting up the tool 1 2 di 4 Upgrade the application software to V7 0 or later Terminate the Console Application including the Service Utility and User Utility if it s running Terminate this tool if it s running In the case of adding tomosynthesis menus and mammography menus make sure if tomography menus and mammography menus exist in the upgraded Console If exist delete them using MenulmportExportTool Refer to the additional menu list for menu codes to perform the operation Ensure that the language setting has been set up appropriately This tool refers
42. al Trial Series DX Series Mammography Series Frame of Reference Equipment General Equipment Image General Image Image Pixel Contrast bolus Display Shutter Device Intervention DX Anatomy Imaged DX Image DX Detector X ray Collimator DX Positioning X ray Tomo Acquisition X ray Acquisition Dose X ray Generation X ray Filtration X ray Grid Overlay Plane C Required if graphic annotation is present Image Table 8 1 30 o P C Q lt CEN No 2012 E 0291Rev 1 _70 No 2012 E 0291Rev 1 70 70 E Module Usage Reference Usage Reference VOI LUT C Required if Presentation Intent Type 0008 0068 is FOR PRESENTATION Shall 5 8 1 26 not be present otherwise Image Histogram BU I Not Supported Acquisition Context IM Table 8 1 27 SOPCommn MC Table 8 1 28 NOTE The IOD includes Private attributes and standard extended attributes documented in Section 8 2 See 8 2 and 8 5 OTABLE 8 1 4 IOD OF CREATED X RAY RADIATION DOSE SR SOP INSTANCES following contents have been changed PRINTED IN BLUE E Megule usage Reterence Patient Patient PM Tesis Study General Study Table 8 1 6 Series Frame of Synchronization Not Supported Reference Equipment Gene Eaupment M ravenna OTABLE 8 1 11 MAMMOGRAPY SERIES MODULE OF CREATED MG IMAGE STORAGE SOP INSTANCES following a were added Aibute tag Dicom Attribute Description Presence of Value Modality 0008 0060 Type of equipm
43. al procedure overwrite ImageProcessing folder with C Program Files FujiFilm IIP lmageProcessing and Param folder with C Program Files FujiFilm lIP Param Both ImageProcessing folder and Param folder are stored in BackupData Before_Conversion lIIP on the desktop Then perform error correction according to Windows message and restart the tool to perform the steps from the beginning Table List of error messages appear while adding menus to DB and how to correct them Message 1 Failed Get Language SysConfig mdb is Not Found MenuData mdb is Not Found XconParam mdb is Not Found Overlapped ExaminationMenuCode Overlapped ExposureMenuCode Failed MammographyMenu Convert 8 Failed TomosynthesisMenu Convert Procedure for error correction Terminate Service Utility or Console if they are running Close SysConfig mdb if it is open If the case is other than above restart the PC Terminate Service Utility or Console if they are running Close SysConfig mdb if it is open If the case is other than above restart the PC If the error occurs even after the PC is restarted application software upgrade to V7 0 or later may have been failed Confirm if the upgrade has been completed properly Terminate Service Utility User Utility or Console if they are running Close MenuData mdb if it is open If the case is other than above restart the PC If the error occurs even after the PC is resta
44. an 18x24cm size Mammography Format image on 26x36cm size film in mammography 20n1 100 format 29 No Print Scale User Definition ea Specifying whether or not to print the Rules a ee scale 5 Gap Between Image Edge and 0 50 00 Gap between image edge and film edge Film Edge Mammography on Mammography Format Single 2 on Format x0 1mm 1 x 0 4mm 61 2636 Film Character Field 0020 Specifying the left hand image film Position amp Rotation Left Image annotation character field position and of 20n1 Mammography Format rotation for outputting an image produced from the mammography menu 18x24cm image to 26x36cm film in 20n1 mammography format 100 magnification 62 2636 Film Character Field 1030 Specifying the right hand image film Position amp Rotation Right Image annotation character field position and ECN No 2012 E 0291Rev 1 38 39 rotation for outputting an image produced from the mammography menu 18x24cm image to 26x36cm film in 20n1 mammography format 100 magnification Film String Format 0 GeneralFormatOnly Specifying whether to use 1 MammographyFormat general format film annotation characters for all images as has been previously or special film annotation characters defined exclusively for mammography images Film Character Mode Setting on 0 DICOM Specifying film annotation characters of XCON Material Info 1 XCON mammography XCON material information 0 DICOM Conforms to the D
45. and area dose of the two types of dose values transmitted from the X CON is to be assigned to Value2 Specifying the setting for output of actual result value when it couldn t be received from the X CON 0 Average Organ Dose 1 Entrance Dose 2 Dose Product 0 Output Default Condition 1 Doesn t Output Anything 1 odd parity 2 even 340 Enable Auto Pairing Yes Specifying whether or not to enable the No auto pairing 5 5 2 Setting up marker BMP for mammography No change has been made from the existing marker files for general X ray system The number of marker file types for mammography exceeds 85 as default and both for Japanese and for other languages exist Be sure to select the markers at the time of installation as there are more than 128 which is the limiting value of markers together with the ones for general X ray system lt Types and numbers of marker files gt C Program files FujiFilm IIP MarkerBmp For general X ray system For mammography Japanese For mammography other languages bmp 84f files Japanese bmp 90 files Other bmp 84 files 5 5 2 1 At the time of new system installation For the case of newly installed system prepare the markers to make them to used as default because the marker files for mammography are stored in the following folders lt The folders in which the marker files for mammography are stored gt C Program files FujiFilm IIP MarkerBmp E
46. as the calibration is performed each time Console terminates normally The following message appears in case Display Calibration Dialog has been set up in the system settings Completion processing is in progress Calibration may take time The system automatically shuts down after a while The calibration is not performed under the following conditions e Shift termination of Console Forced termination of Console upon occurrence of power outage e Forced termination of Console upon occurrence of error Activation of the User Utility Refer to the relevant ECN concerning MC for details of time required for the calibration 2 4 Settings Cautions concerning installation In the case of mobile PC installation a multimedia drive is required as a service jig for installing the application software in CDs Install the MC application 114Y2194xxxAxx in the PC where Conosle Advance V7 0 has already been installed Refer to the service manual of MC application or relevant ECN for the procedure ECN No 2012 E 0291Rev 1 18 39 2 4 1 Network configurations Note the following cautions because integrated MC configuration requires two LAN ports Do not use duplicated IP addresses Do not set IP addresses in the same subnet for the two ports Set up priority of network bindings appropriately Win the case of desktop PC lt System configuration example gt Wired Clustering ES e I e o a Wired in hospital
47. d in the Service Manual use the CD for the installed software version to uninstall the precise enlargement software When the free layout print software has been installed uninstall the free layout print software according to the Service Manual Installation Appendix AppxIN Appendix 7 Uninstallation of AP 8 Free Layout Print Software Insert the DR ID 300CL V7 0 Application Disk into the DVD drive The setup menu of the Console Advance appears automatically If not select Start Start Search input D Setup bat and then press the lt Enter gt key C Windows system32 cmd exe E A gt Quit 1 gt Install Database Management System 2 Install DR Console Application 3 Install Parameter Files Menu DB Image Processing Parameter etc 5 gt 0pen Add Remove Programs Uninstall Application 6 gt 0pen Add Remove Hardware Uninstall Device Driver 16 gt Install FRIS Modules 11 gt Install WakeOnLAN Application 12 gt Install Uninstall BENEO Modules 13 gt Install Bitmap Files Japanese Only 17 gt Install RAID Status Display Tool 18 gt Install PPS Cache Server 17 gt Install SKB Launcher 24 gt Set up Remote Image Display 21 gt 8et up Tomosynthesis 46 gt Set up GPR Default Parameter 41 gt Set up Mask Processing Default Parameter SA 3I Install PDI Application 669 Install Precise Enlargement Function Application 65 gt 5Install Free Layout Print Application Select Number gt Enter 5 and
48. d on 26x36cm size film in the single mammography format or to 18x24cm size images that are printed on 8 x10 size film in the single mammography format Yes Specifying whether or not to add image 28 Print Image Frame 2636film 18x24 20n1 100 No frame when printing an 18x24cm size image Mammography Format on 26x36cm size film in mammography 2on1 100 format 57 Gap Between Image Edge and 0 50 0 Gap between image edge and film edge on Film Edge Mammography Mammography Format Single 2 on 1 x Format x0 1mm 0 1mm 61 2636 Film Character Field O020 Specifying the left hand image film Position amp Rotation Left Image of annotation character field position and 20n1 nti Format rotation for outputting an image produced from the mammography menu 18x24cm image to 26x36cm film in 2on1 mammography format 100 magnification ECN No 2012 E 0291Rev 1 66 66 2636 Film Character Field 1030 Specifying the right hand image film Position amp Rotation Right Image annotation character field position and of 20n1 Mammography Format rotation for outputting an image produced from the mammography menu 18x24cm image to 26x36cm film in 2on1 mammography format 100 magnification Film String Format 0 GeneralFormatOnly Specifying whether to use general format film 1 MammographyFormat annotation characters for all images as has been previously or special film annotation characters defin
49. d processing parameter presets PEM processing W gradation parameter Registration of implant information Registration of View code View Modifier code DICOM MG Storage for Presentation Film print for mammography XCON connection for mammography excepting Siemens s XCON for mammography V7 0 does not support the following functions as they will be supported on V7 1 Automatic positioning of levels of right and left breasts Auto positioning Acquisition of exposure records from X ray exposing controller for mammography XCON for mammography Siemens s XCON for mammography QC of the reader unit for mammography images Chest wall paint DICOM MGStorage for processing Fixed output of Windows level under unnormalized output Type output 5 2 Disabling mammography functions for the US Currently 510k clearances have not been granted yet in the US Mammography functions therefore has not been supported For this reason disabling mammography functions is required in the US Disabling each item Do not set up the following configurations concerning mammography functions 5 3 Option key Do not install the option key 5 4 1 Mammography study Do not change it from the default setting Note however that set up the following if the user wishes to use DX Storage for the general studies 1 IMAGE MODALITY 54 Modality Setup 0 DX 1 IMAGE MODALITY 35 Modality Setup for Mammography Image 0 M G 5 4 2 PEM processing
50. d to prevent the errors on HQ images Image processing error sometimes occurs when the images retrieved from FDRA cSelerate are output in 20n1 The error in the distance correction processing has been corrected Potential errors Error description Revision on the error messages FLP 1008 FLP 1010 FLP 1011 for Free Layout Print SS Displayed status of enabled emergency use does not disappear in some cases Ls No selector names are displayed in the thumbnails of some menus E Image number for DR five images long view is incorrect eee A speck is attached to the cursor in TomoView window on the 2 monitor nn al Error TS0008 occurs when Console with tomosynthsis setting is being started ee up The operation is disabled with locked button when retransferring images fails 8 The status display appeared during calibration does not disappearinsomecases ts E causing a subsequent system down KE te mere rese output is performed in FLP Terme a e ee multiple FLP templates were registered Clustering consistency check is not viewed in some cases even though a Verification of Setting with other host is selected i ee some cases during termination processing A particular operation on long view images taken with DR cassette disables Echo QU ECN No 2012 E 0291Rev 1 4 39 4 Installation Procedure 4 1 Cautions concerning upgrading installation Note 1 Upgrading installation to DR ID 300CL
51. e MA 51 Xcon Exposure Info Limit Value 0 to 9999 1 Minimum irradiation time erre ee ee msec 52 Xcon Exposure Info Limit Value 0 to 9999 5400 Maximum irradiation time Maximum Exposure Time msec 76 PPS Exposure Status Sequence 0 No Specifying whether the PPS should 1 Status Only return the exposure status such as 2 Status Other Results repeat reject of exposures with a 108 Xcon Format Type 0 Old 1 Old Expand 2 Old Expand2 4 Mammo 1 5 Mammo2 6 Mammo3 Yes No 0 1200 1 2400 Xcon Interlock Command Transfer Xcon Serial_ TX Baudrate ECN No 2012 E 0291Rev 1 Private tag 39 39 Specifying the X CON type Specifying whether or not to transmit the interlock command Specifying the X CON serial transfer rate unit bit 2 4800 111 3 9600 Xcon No ResponseTimeout 0 to 255 20 Xcon Data Reception Timeout 0 to 255 20 Xcon DoseValue1 0 Average Organ Dose 1 Entrance Dose 2 Dose Product Xcon DoseValue2 Xcon No Data Default Output Specifying the timeout valuefor response coming from the X CON unit 100msec Specifying the timeout value for reception of data coming from the X CON unit 100msec Specifying which of the mammary gland absorption dose exposure dose and area dose of the two types of dose values transmitted from the X CON is to be assigned to Value Specifying which of the mammary gland absorption dose exposure dose
52. e studies were executed in MWM Also RE00000 error occurs when the studies are started 2 Images cannot be transferred from FCR5000 to Console Advance Caution Be sure to install HF0001 Base V7 0 ECN 2012 E 0293 before using V7 0 APPLICABLE TO Serial Nos etc DR ID300CL Software V5 0 V6 0 V6 1 V6 2 included HF ESTIMATED WORK TIME 0 HOURS A o SPECIAL TOOLS INSTRUMENTS OYES DINO Application SUPPLY OF THE ARTICLES KIYES CINO eae not IF YES WHEN At the same time with this ECN a eee NAME CODE DR ID 300CL Application Software V7 0 114Y2150001B04 QUANTITY 1set of 1DVD RETURN OF THE REPLACED PARTS TO FUJI IYES KINO DOCUMENTS AFFECTED YES INO AFFECTED CURRENT DOCUMENTS ISSUED DATE ISSUED DATE Le Ai ia A I DETAILS See the attachment for details The contents described or shown in our ECN documents and or any information provided from FUJIFILM in verbal or written communication is intended for the addressee and or its organization Transfer and or copy distribution of the information without written consent of FUJIFILM is not permitted PAGE 1 of 2 K12N0028 6 J ECN No 2012 E 0291Rev 1 1 Important information about SUPPLY OF THE ARTICLES Charge x FREE OF CHARGE UNTIL mmddyyyy _ _ WITH YOUR CHARGE NOT APPLICABLE The contents described or shown in our ECN documents and or any information provided from FUJIFILM in verbal or written communication is intended for the address
53. eading images by inserting pantomography IPs into 15x30 IP adapter 1 to be read as 14 x17 size and by trimming them to 10 x12 in size on Console Advance The details of the procedure are as follows 1 Inserting the pantomography IP to it makes the IP readable as 14 x17 cassette Procedure 1 Make an exposure with a FCR cassette in the pantomography size 2 Remove the IP from the cassette used in step 1 above 3 Insert the IP removed in step 2 above into the 15x30 IP adapter 4 Read the 15x30 IP adapter with PROFECT P reader unit Retrieve the image in 14x17 size Console Advance receives 14 x17 image from PROFECT P 5 Perform trimming if necessary Trimming to the pantomography size is not supported Perform trimming to 10 x12 sized image instead Automatic trimming when receiving images and manual trimming on QA window will be performed 11 2 Option key None 11 3 Details None 11 4 Settings 11 4 1 Service Utility Settings No change 11 4 2 User Utility Settings None 11 5 Effects on the other functions None 11 6 Cautions None ECN No 2012 E 0291Rev 1 54 54 DR ID 300CL V7 0 ECN Appendix B Extended parameter convert tool 1 Outline 1 1 Contents In response to supporting tomosynthesis and mammography some menus have been added and image processing parameters have been changed Also V7 0 includes the image processing parameter that is exclusively for monitor and for
54. ection Refer to Appendix A Integrated MC Refer to Appendix A 3 Supporting high sensitivity mode of automatic X ray Refer to Appendix A detector 4 Image acquisition without exposure under the Refer to Appendix A condition where automatic X ray detector activated Supporting CR mammography Refer to Appendix A 6 _ Improvement in operatability of tomosynthesis Refer to AppendixA 8_ Improvementin QA termination button RefertoAppendix A 9 Storing worklist when retrieving MWM fails RefertoAppendix A 10 Revised default settings for exposure condition Refer to Appendix A XconParam mdb Supporting PROFECT P connection Refer to Appendix A ECN No 2012 E 0291Rev 1 2 39 3 Correction of Errors Found in the Field Error description and details of correction Console stops operation with showing the message Terminating while terminating on the systems where media storage is used Termination processing has been revised Log has been enhanced on V7 0 Images cannot be transferred from FCR5000 to Console Advance There was a problem on the management of image input status The program has been corrected The studies are not deleted from the list even after the studies were executed in MWM Also RE00000 error occurs when the studies are started The logic to delete executed studies was defective The program has been corrected Appearance of images becomes different on PACS when they are tran
55. ed exclusively for mammography images Film Character Mode Setting on 0 DICOM Specifying film annotation characters of XCON Material Info mammography XCON material information 0 DICOM Conforms to the DICOM definitions as has been so previously 1 XCON Conforms to the XCON I F definitions 5 CSL IDT FUNCTION 109 Xcon Interlock Command Yes Specifying whether or not to transmit the 117 Xcon DoseValue1 0 Average Organ Dose Specifying which of the mammary gland 1 Entrance Dose absorption dose exposure dose and area 2 Dose Product dose of the two types of dose values transmitted from the X CON is to be assigned to Value 118 Xcon DoseValue2 0 Average Organ Dose Specifying which of the mammary gland 1 Entrance Dose absorption dose exposure dose and area 2 Dose Product dose of the two types of dose values transmitted from the X CON is to be assigned to Value2 No auto pairing 1 No during calibration No mode for DR cassette ha Time out Value in High Sensitive 30 Time out value for the high sensitivity Mode The value range is 5 60 mode sec 354 MPM Code for QC Lag Image 091E Console receives a blank image after the Multiple values can be time for the high sensitivity mode is over in input by separating them the case of selected MPM code by commas ECN No 2012 E 0291Rev 1 67 67 DR ID 300CL V7 0 ECN_Appendix D List of Changes in Conformance Statement This chapter describes the chan
56. ee and or its organization Transfer and or copy distribution of the information without written consent of FUJIFILM is not permitted PAGE 2 of 2 K12N0028 6 J ECN No 2012 E 0291Rev 1 1 39 Rev 1 Releasing the information of the DR ID 300CL Application Software V7 0 1 Released items E Id LDR ID een eee boogie De li DR ID 300CL Standard Kit V5 114Y2150003B04 DR ID 300c Standard KitLite V30 11a2180004B04 CO DR ID 300CL V6 2 Reference Guide 7th Edition for Software single sales 114Y2150053B05 CD 1 Options The following option which has already been released for other products can be applied to DR ID 300CL from V7 0 onward Only the CD label has been replaced from the existing parts Product names Parts number Media Number of media CR IR348CL DR ID 300CL PEM Key Software V1 0 114Y5342306A00 CD Service Tool nme eee ese RT DR ID 300CL Menu Import Export Tool V5 1 114Y2150758B02 CD 1 Hardware TTT Product names _ _ _ _ _ names N for installing the integrated MC Extended LAN board gevin ee ee Driver CD is included Extended LAN board for 780DT 113Y100502 Necessary for installing the integrated MC Additional memory for 760 960 2GBx2 113Y100849 Necessary for installing the integrated MC Additional memory for 780 790 990 2GBx2 113Y 100843 Necessary for installing the integrated MC 2 Mainly Extended Improved Functions Developed item 2430C conn
57. ems to distinguish the panel when registering the DR cassette in the Service Utility Device setting Device Color Device Name Selector setting Caption 1 4 2 User Utility Settings The additional panel type items in the User Utility are as follows Preset the image processing parameter that is exclusively for 2430Csl Menu Setting Select a menu and click Edit Setting for DR at the bottom of the window Exposure parameter 1 Llmage Processing parameter setting Image Processing Panel Type Select it in the case of 2430Csl Select it in the case of HandyModule Applicable only in Japan Select Csl M for Panel Type Image Processing ECN No 2012 E 0291Rev 1 14 39 wes UN i iD D ae L S J G C C C i 1 5 Effects on the other functions None 1 6 Cautions None ECN No 2012 E 0291Rev 1 15 39 2 Integrated MC 2 1 Outline Modularized MC configuration has realized the integrated MC which does not require a PC for MC That configuration enables exposures using DR cassette as is conventionally done Also This function calibrates DR cassette each time Console is terminated MC software V4 0 or later is required Refer to the relevant ECNs for details of supported panel types 4GB memory additional 2GB to the standard requirement and two LAN ports additional NIC card extension to the standard requirement are required for the PC of Console Advance 2 2 Option key None 2 3
58. ent that originally ALWAYS z lt lt i acquired the data used to create the Value is MG images in this Series Enumerated Values MG Coded Reason for requesting this procedure gt Reason for 0040 100A Requested Procedure Code Sequence One or more sequence items may be present Request 0040 0275 Sequence that contains attributes Attributes from the Imaging Service Request Sequence The sequence may have one or more Items ECN No 2012 E 0291Rev 1 71 71 OTABLE 8 1 19 MAMMOGRAPHY IMAGE MODULE OF CREATED MG IMAGE STORAGE SOP INSTANCES following IES have been added Dicom Attribute Description Presence of Value Source Positioner 0018 1508 Type Enumerated Values ALWAYS MAMMOGRAPHIC Value is NONE MAMMOGRAPHIC Positioner 0018 1510 Position in degrees of the X Ray EMPTY Primary Angle beam vector in the coronal anatomical plane as if the patient were standing where movement of the X Ray source from right to vertical is positive and vertical is zero Positioner 0018 1511 Position in degrees of the X Ray EMPTY AUTO Secondary beam vector in the sagittal Angle anatomical plane as if the patient were standing where movement of the X Ray source from anterior to posterior is positive and vertical is Zero Image 0020 0062 Laterality of the region examined ALWAYS CONFIG Laterality Enumerated Values USER R right L left B both e g cleavage AUTO AUTO
59. following values have already been registered as default values View Code DICOM PS3 16 2009 CID4014 View Modifier Code DICOM PS3 16 2009 CID4015 5 4 6 DICOM MG Storage E Enabling the functionality Select MG Image Storage For Presentation in the Service Utility Limitation MGImageStorageForProcessing cannot be selected 5 4 7 Film print for mammography Limitation Images cannot be output to 10 x12 in film size 5 4 8 X CON connection for mammography Excepting Siemens s mammography X CON W Configurations Set up the configuration items according to the following table when establishing the connection to each manufacturer s mammography X CON Setup Configuration Item SYSTEM CONFIG 5 CSL IDT FUNCTION No Config Item Toshiba Lorad GE Planmed IMS Fed Instrumentarium Xcon Serial TX To be set To be set To be set in the To be set To be set Control Port in the in the range of 1 to 3 in the in the range of 1 range of 1 range of 1 range of 1 10 3 lo 3 108 Xcon Format Type 4 Mammo1 5 Mammo2 5 Mammo2__ 5 Mammo2 5 Mammo2 6 Mammo3_ kalt e CR Command Transfer Baudrate I I A IS IS LA No Response Timeout hae re e_N Timeout 17 xen net bose Dese Dose Dose Doce Dose Dose Dose Dose Dose A see rae lee Product Product Product Product Contr ee ee ee eee ECN No 2012 E 0291Rev 1 37 39 Cal ee eee eee eee ee 142 Xcon Serial TX 2 even Parity Siemens s X CON will
60. ftware manually Click Browse button Update Driver Software Intel R Gigabit CT Desktop Adapter l x G L Update Driver Software Intel R Gigabit CT Desktop Adapter Browse for driver software on your computer Search for driver software in this location CA Users Administrator Documents Browse I Include subfolders gt Let me pick from a list of device drivers on my computer This list will show installed driver software compatible with the device and all driver software in the same category as the device ECN No 2012 E 0291Rev 1 20 39 15 Select the DVD drive and click OK button x Select the folder that contains drivers for your hardware E ji Computer A Local Disk C BEREDD RW Drive D 114Y2150764800 APPS PLATFORM PRO100 PRO1000 PROXGB m ia Network WORK Fair DVD RW Drive D 1142150754800 e si HH H 16 Click Next Update Driver Software Intel R Gigabit CT Desktop Adapter x G L Update Driver Software Intel R Gigabit CT Desktop Adapter Browse for driver software on your computer Search for driver software in this location I Include subfolders Let me pick from a list of device drivers on my computer This list will show installed driver software compatible with the device and all driver software in the same category as the device After a while the driver software will be updated and a message window notifying complet
61. ges from the DR ID 300CL V6 2 Conformance Statement 1 Changes related to Handling of the SOP Class E Digital Mammography X Ray Image Storage For Presentation support OTABLE 4 2 15 SOP CLASSES FOR THE STORAGE SCU AE SOP Class Name SOP Class UID scu s Digital Mammography X Ray Image 1 2 840 10008 5 1 4 1 1 1 2 Yes No Storage For Presentation OTABLE 4 2 20 POPOSED PRESENTATION CONTEXTS FOR ACTIVITY SEND IMAGES Presentation Context Table Abstract Syntax Transfer Syntax Role Ext Name UD namens umus Neg Digital 1 2 840 10008 5 1 4 1 1 Implicit VR Little Endian RI 840 10008 1 2 SCU None Mammography 1 2 Explicit VR Little Endian 1 2 840 10008 1 2 1 X Ray Image JPEG Lossless 1 2 840 10008 1 2 4 Storage For Hierarchical First Order 70 Presentation Prediction OTABLE 5 3 2 SOP CLASS AUGMENTATIONS Information Object SOP Class UID Transfer Syntax Transfer Syntax UID Definition Digital Mammography Image 1 2 840 10008 5 1 4 1 1 1 Implicit VR Little Endian 1 2 840 10008 1 2 Storage For Presentation Only AUG GEN DVD RW AUG GEN USB Explicit VR Little Endian 1 2 840 10008 1 2 1 JPEG Lossless 1 2 840 10008 1 2 4 7 Hierarchical First Order 0 Prediction 2 Tag Additions Changes WE Digital Mammography X Ray Image Storage For Presentation support OTABLE 8 1 1 IOD OF CREATED CR IMAGE STORAGE SOP INSTANCES following contents have been changed PRINTED IN BLUE ie Module
62. gged distance when dragging the mouse obliquely Note however that the values remain the same even though the mouse is moved when the values of GA GS have already reached their maximum GA larger Dragging upward downward GA upward larger downward smaller GS smaller GS larger Dragging left right GS left smaller right larger GA smaller This function is enabled in response to mousedown in the image display field in the red dotted frame in the following figure FUJI TAROU The values can be changed while mousedown operation is continued even when the cursor runs off the edge of image display field ECN No 2012 E 0291Rev 1 47 47 The setting disabled The setting enabled GA GS values are displayed below the QA function buttons SN QA Home 7 4 Settings 7 4 1 Service Utility Settings Set up the following in the Service Utility Setup Configuration Item SYSTEM CONFIG 3 QA FUNCTION Name Area Default value 22 Enable Adjust GA GS by No Enabling Disabling GA GS adjustment by dragging Yes dragging mouse 3 ResponceGA 0 99 18 Making smaller GA sensitivity value more sensitive when performing GA GS adjustment by dragging mouse 24 ResponceGS 0 99 18 Making smaller GS sensitivity value more sensitive when performing GA GS adjustment by dragging mouse 7 4 2 User Utility Settings None 7 5 Effects on the other functions None 7 6 Cautions None ECN No
63. gh sensitivity button in the figure below appears when all the following five conditions are satisfied The button does not appear unless all the conditions are met 1 Setup Configuration Item SYSTEM CONFIG 5 CSL IDT FUNCTION item318 Use X ray Free Operation Mode is set to Yes 2 Setup Configuration Item SYSTEM CONFIG 5 CSL IDT FUNCTION item352 Use X free High Sensitive Mode new is set to Yes Enable X Free for DR cassette is set to Yes in Device Setting The corresponding selector has been selected in the Study execution window and unexposed menu is selected 5 ShotReady is turned ON 3 o High sensitivity button lt Transition to the high sensitivity mode gt Clicking the high sensitivity button can change the selected DR cassette into the high sensitivity mode The following dialog appears to notify that the high sensitivity mode is turned on ECN No 2012 E 0291Rev 1 27 39 A progress bar appears to show that the high sensitivity mode has been entered The exposure must be made while the progress bar is indicating the remaining time to complete it The time out value is a service setting The default value has been set to 30 seconds Em The cancel button that cancels the high sensitivity mode and changes it to the normal mode to return it to QA window CHEST FRN P gt A DR s 17 X17 Time remaining to complete exposure lt Limitation gt 1 Console
64. gs Contents DR ID 300CL V7 0 ECN Appendix A Functional Settings 12 1 2430C Connection 12 2 Integrated MC 15 3 Supporting high sensitivity mode of automatic X ray detector 26 4 Image acquisition without exposure under the condition where automatic X ray detector activated 29 5 Supporting CR mammography 31 6 Inprovement in operatability of tomosynthesis 38 7 Enabling GA GS adjustment using mouse 38 8 Improvement in QA termination button 38 9 Storing worklist when retrieving MWM fails 38 10 Reviwsed default setting for exposure condition XconParam mdb 38 11 Supporting PROFECT P connection 38 1 2430C Connection 1 1 Outline It supports the image read using indirect conversion Flat Panel Detector 2430C that applies a newly developed Csi scintillator MC software V4 0 or later is required 1 2 Option key None 1 3 Details 1 Automatic trimming Retrieved images are automatically trimmed according to their sizes when receiving images from DR cassette reader unit See the following for the case of 24cm x 30cm fixed size 24cm x 30cm images 24cm x 30cm no trimming 8 x 10 The retrieved image 23 4cm x 28 8cm in size is trimmed and displayed in 24cm x 30cm 2 Trimming settings Refer to the table below for the trimming sizes for the case of images 24cm x 30cm in size Actual trimming frame size Read image size 24cm x 30cm No trimming 23 4cm x 28 8cm TETA Cannot be specified Ibi Cannot be specified 14 x
65. gs to default 4 4 Installing menus for mammography tomosynthsis and film to monitor conversion Install the menus for mammography exposure menus and image processing parameters Tomosynthsis and film to Monitor Conversion Refer to 4 1 Note 6 above 1 Insert the DR ID 300CL V7 0 Application Disk into the DVD drive Execute D tools ExtendedParamConvertTool ExtendedParamConvertTool bat in Explorer Enter 2 From Console Advance Enter y for Add Mammography Menu 5 Enter n or y if necessary Enter n if Tomosynthsis menu has already been used for Add Tomosynthesis Menu 6 Enter 2 US or 3 outside US for Select Language 7 Enter 1 for film or 2 for monitor for Select Parameter Type 8 Enter 1 for Select Xcon Parameter Type 9 Enter n or y if necessary Enter n if the image processing parameter for the monitor has already been used for Film to Monitor Conversion 10 Enter y for Do you want to implement 11 Enter y for Do you want to apply the system 12 Enter 0 Quit 13 Remove the DR ID 300CL V7 0 Application Disk from the DVD drive YAN Refer to Appendix B Extended parameter convert tool for details Na n _ Dj N 2 3 4 4 5 Installing the electronic manual Install the electronic manual 4 6 Additional setup items for the systems using
66. he system has the secondary monitor connected Setup Configuration Item LUT 2nd Monitor LUT 21 The location of tube configuration data which was stored in TubeConfig ini file in V6 2 or earlier has been changed to Selector mdb in V7 0 For this reason set up the tube configuration data under the selector settings in the Service Utility 22 Click Root tools FirewallSetting bat on the DR ID 300CL V7 0 Application Disk 23 When Press any key to continue appears press the lt Enter gt key 24 For the systems that are connecting to the TOSHIBA modality click Root tools CopyReserveCode1FromMicroAs bat in the DR ID 300CL V7 0 Application Disk 25 When a confirmation dialog appears press the OK button Twice in total AN 26 Click Root tools DeleteReceiveDateAndReceive Time DeleteReceiveDateAndReceiveTime bat on the DR ID 300CL V7 0 Application Disk 27 When Press any key to continue appears press the lt Enter gt key 28 Remove the DR ID 300CL V7 0 Application Disk from the DVD drive 4 3 Replacing the default settings of exposure condition XconParam mdb if necessary As the default values of exposure conditions have been changed to reliable CR console values from V7 0 replace XConPara mdb if necessary Refer to 9 Revised default settings of exposure condition XconParam mdb in Appendix A_Function settings Caution Replacing XConParam mdb changes all the menu settin
67. ility Setup Configuration Item SYSTEM CONFIG 1 IMAGE MODALITY Area Default value Image File Type For Types of image to display on the Tomosynthesis Viewer tomosysthesis viewer 0 image reduced 1 2 in size 350 Display Pixel Size for 1_ 264 2nd monitor 1 image with standard density Set up the LUT for the 2 monitor in the Service Utility Display pixel size 0 001mm of the 2 monitor Setup Configuration Item LUT 2nd Monitor LUT Monitor List 1 st Monitor LUT nanao LEKOT C nd Monitor LUT r A Linear LUT Select the model of the monitor used for the 2 monitor 6 4 2 User Utility Settings None 6 5 Effects on the other functions None 6 6 Cautions Concerning the configurations for setting up the 2nd monitor Set up the tomosynthesis function on Console Set up the precise enlargement function on the linked application ECN No 2012 E 0291Rev 1 46 46 7 Enabling GA GS adjustment using mouse 7 1 Outline Like CR Console and Console Advance V4 0 or earlier V7 0 enables GA GS adjustment using mouse drag on the QA window 7 2 Option key None 7 3 Details Dragging mouse changes GA GS values applied to the image displayed on the QA main window The values will be changed and the image displayed will be updated according to the directions of the dragged mouse as follows same as V4 Both GA and GS values can be changed simultaneously to the amount of dra
68. ion of driver installation will appear 17 Click Close in the message window Update Driver Software Intel R Gigabit CT Desktop Adapter f x P J Update Driver Software Intel R Gigabit CT Desktop Adapter Windows has successfully updated your driver software Windows has finished installing the driver software for this device Intel R Gigabit CT Desktop Adapter a The hardware you installed will not work until you restart your computer ECN No 2012 E 0291Rev 1 21 39 18 Click No when System Setting Change message appears System Settings Change Your hardware settings have changed You mustrestart your computer for these changes to take effect Do you want to restart your computer now 19 The window returns to the Device Manager Select the extended NIC and right click it to select Properties A Device Manager File Action View Help e H H El g DA26726851 jil Computer Eg Disk drives fy Display adapters Fk DVD CD ROM drives Hg Human Interface Devices H E IDE ATA ATAPI controllers espe Keyboards FA A Mice and other pointing devices E Mail Monitors E Network adapters EP Intel R 82579LM Gigabit Network Connection e Yee Intel R Gigabit CT Desktop Adapter Bro i I sal H Ports COM amp LPT Update Driver Software FUE Processors Disable Security Devices Uninstall H a Sound video and game controllers E J System devices Scan for hardware change
69. jiFilm lIP Param in BackupData Before_Conversion lIP Param 2 Save the data converted after selecting options in step 2 to 7 in BackupData After_ Conversion on the desktop temporarily 4 2 Application of converted data to Console In the case of selecting y in response to Do you want to apply the system prompt in step 10 to confirm application of converted data to Console which is described in 3 3 Operational procedure above apply copy the converted data created in step 9 to the folder in Console Refer to 5 Applicable files for the files to apply the converted data to Refer to the additional menu list for the menus added as a consequence of additional mammography and tomography menus ECN No 2012 E 0291Rev 1 59 59 5 Applicable files The following files will be converted using this tool Folder path RCS C Program Files FujiFilm IP Param MenuData mdb Menu data DB DB C Program EDR parameter 4 Files FujiFilm lIIP lmageProcessing I mpmprm prm EDR parameter ae mageProc Type Builtin C Program EDR parameter LI Files FujiFilm IIP ImageProcessing l mpmprm prm EDR FERRE mageProc Type Cassette 7 FNCd prm hac processing parameter ME TA Files FujiFilm IIP lmageProcessing l 7 5 parameter l bic parameter 10 Stdd prm Image processing parameter parameter menu Image processing adding tomosynthesis parameter menu e brodram MFPd prm Image processing yg Files FujiFilm IP mage
70. lected other then CR 8 Film to Monitor Conversion Confirm the change of film monitor conversion image processing parameter Execute it Enter y Do not execute it Enter n 9 Do you want to implement Confirm execution of convert processing GG Execute it Enter y Do not execute it Enter n Entering n returns to step 2 above 10 Do you want to apply the system Confirm application of the converted data to Console 66 Apply it Enter y Do not apply it Enter n Entering n returns to step 2 above Refer to Error handling for the procedures if errors occur while performing the steps above ECN No 2012 E 0291Rev 1 58 58 4 Automatic data backup before and after conversion and application of converted data to Console 4 1 Automatic data backup of setup files In the case of selecting y in response to Do you want to implement prompt in step 9 to confirm execution of convert processing which is described in 3 3 Operational procedure above 1 Create backup data of Console in BackupData Before_Conversion lIP on the desktop Attention is required when restoring the backup data as there are only following two folders stored in the folder above 1 Create backup of C Program Files FujiFilm IIP lmageProcessing in BackupData Before_Conversion lIP lmageProcessing 2 Create backup of C Program Files Fu
71. moane Reference Presence _ Table 8 1 5 ALWAYS General Study Table 8 1 6 ALWAYS Patient Study Table 8 1 7 ALWAYS ECN No 2012 E 0291Rev 1 80 80 Module Reference Presence es o Table 8 1 9 ALWAYS Equipment General Equipment Table 8 1 12 ALWAYS General Image Table 8 1 13 ALWAYS Image Pixel Table 8 1 14 ALWAYS Contrast bolus Table 8 1 15 ALWAYS CR Image Table 8 1 17 ALWAYS Modality LUT Table 8 1 25 ALWAYS VOI LUT Table 8 1 26 ALWAYS SOP Common Table 8 1 28 DX Positioning Table 8 1 21 ALWAYS X ray Acquisition Dose Table 8 1 23 ALWAYS X ray Generation Table 8 1 2 ALWAYS
72. nd to the End Read error from the cassette reader unit Consequently ST10001 error occurs End Read error processing has been revised The Selector cannot be switched to VELOCITY even after the menu was set to automatic trimming in 10 x14 Defective setting of 10 x14 trimming for VELOCIRTY has been corrected Shifting the center of trimming of images in the pantomography format disables film output The program has been revised to enable film printing A message appears on the master Console when an unregistered IP error is detected on the reader unit The content of the message has been revised Wrong PPS SOP Instance UID is issued when a study is suspended in PPS and then is resumed subsequently The program has been revised to issue the same UID os aw aX s ex x 00 N O O1 gt Q9 N ECN No 2012 E 0291Rev 1 3 39 Order information of Simple Ordering cannot be retrieved when restarting RIS in which there is a shared folder The program has been revised to enable the data acquisition after the connection is established Study menu name using special characters such as umlaut is garbled when study menu mapping is executed on the studies from RIS The program has been corrected to prevent garbles On FCR images QA00007 occurs when double clicking to enlarge the image and QA10014 occurs when enhancing the edges of the image The program has been revise
73. network Wired local network for image transfer Installing extended NIC Cautions For the case of HP 6200ProSF 8200EliteMT Install NIC Board Driver after EXPI9301CT PCIExpress board has been installed For the case of DELL Optiplex 780DT gt Install PWLA8391GTL PCI board 1 For the cases other than above Install EXPI9301CT PCIExpress board only Installation of NIC Board Driver is not necessary 1 DELL Optiplex 780DT has only one expansion slot for PCIExpress other PCs have multiple slots Taking possibility of secondary monitor installation into consideration keep the slot for the secondary monitor Therefore use PCI board extended NIC instead of PCIExpress board Olnstalling EXPI9301CT PCIExpress board 1 Shut down the PC and remove all the cables connected to the PC 2 Remove the cover of the PC 3 Turn up the card hold latch to remove the filler bracket placed in the card slot opening of unused PCIExpress card Insert the board into the unused PCIExpress card slot Turn down the cardholder latch to fasten PCIExpress board Put the cover back on the PC Attach all the cables removed in step 1 above Connect on board NIC to in hospital network and extended NIC to local network for image transfer Turn on the PC O 0 NDOU A Na Nr yy Nee OOo YO Note Perform the following driver updating procedure only for the case of HP 6200ProSF 8200EliteMT Do not perform the following procedure on D
74. ng worklist 9 3 Details Show the message to notify the user if a query to RIS fails The probable causes of failure are as follows The network connecting to RIS has not been established The connection to RIS cannot be established the negotiation with RIS has been aborted Anomalous values have been retrieved from RIS as a result of a query C FIND RSP 9 4 Settings 9 4 1 Service Utility Settings No change 9 4 2 User Utility Settings None 9 5 Effects on the Other Functions None 9 6 Cautions The worklist will be cleared if none of the order is retrieved even when a query to RIS is successful ECN No 2012 E 0291Rev 1 52 52 10 Revised default setting for exposure condition XconParam mdb 10 1 Outline On V7 0 the default value for XconParam mdb has been changed to the one used in CR Console Note however that the values used exclusively for DR exposures tomosynthesis energy subtraction has not been changed from V6 2 10 2 Setup procedure The following procedure can replace the value for XconParam mdb Caution Because all the menu data is initialized the customized data will be deleted Insert the installer media into DVD drive Select 3 Install Parameter Files Menu DB Image Processing Parameter etc in the installation menu Select the language Select monitor film The following menu will appear Be sure to select 1 for CR N N O1 Q9 n x Nr y_ Sr Nr Select Xc
75. nnected to in hospital network Extended network card connected to local network for image transfer For mobile PC PRAM 46B LAN USB wireless LAN adapter Two wireless LAN ports including on board are necessary in case wireless LAN is used for both in hospital network and local ECN No 2012 E 0291Rev 1 17 39 network for image transfer the on board network card wired connected to in hospital network local network for image transfer the on board network card wireless connected to in hospital network local network for image transfer Extended network card wireless connected to in hospital network WE Synchronized startup with Console Startup Console and MC application start up simultaneously when Console PC is turned on Termination Synchronized with termination of Console MC application terminates under the following conditions Normal termination of Console e Shift termination of Console e Forced termination of Console upon occurrence of power outage MC application does not terminate under the following condition Activation of the User Utility Calibration is performed when Console terminates The system does not shut down until the calibration processing is completed e The system shuts down after the calibration processing is completes Details of the calibration processing are as follows WE Calibration processing during termination of Console Termination of Console takes time
76. nt Study Clinical Trial Study Series General Series Clinical Trial Series DX Series Frame of Reference Equipment General Equipment Image General Image Image Pixel Contrast bolus Display Shutter Device Intervention DX Anatomy Imaged DX Image DX Detector X ray Collimator DX Positioning X ray Tomo Acquisition X ray Acquisition Dose X ray Generation Image X ray Filtration ECN No 2012 E 0291Rev 1 69 69 IE Module Usage Reference Overlay Plane C Required if graphic Table 8 1 30 annotation is present VOI LUT C Required if Presentation Intent Type 0008 0068 is FOR PRESENTATION Shall 129 e 8 1 26 not be present otherwise Image Histogram A Not Supported U Acquisition Context Table 8 1 27 SOP Common M Table 8 1 28 OTABLE 8 1 3 IOD OF CREATED MG IMAGE STORAGE SOP INSTANCES following contents have been added Reference Table 8 1 5 Not Supported Not Supported Table 8 1 6 Table 8 1 7 Not Supported Table 8 1 8 Not Supported Table 8 1 10 Table 8 1 11 Not Supported Table 8 1 12 Table 8 1 13 Table 8 1 14 Table 8 1 15 Not Supported Not Supported Not Supported Table 8 1 16 Included in the Mammography Image Module Table 8 1 18 Table 8 1 20 Not Supported Table 8 1 21 Table 8 1 22 Table 8 1 23 Table 8 1 24 Table 8 1 29 Not Supported Patient Patient Specimen Identification Clinical Trial Subject General Study Patient Study Clinical Trial Study Series General Series Clinic
77. ome changes such as menus Confirm image orientation after changing menus and then execute the processing 5 5 Cautions for DVI connection between PC and monitor Turn on the monitor before PC when connecting PC and monitor with DVI The display size of the Console screen may become small if the monitor is turned on after PC The following message may appear when the PC was left untouched over 20 minutes and then operation is resumed from the status that the monitor is OFF OM30005 The screen resolution has been changed e Please restart the system Restart is not necessary because pressing the OK button on the dialog can continue the operation 5 6 Caution use Simple Ordering Function when importing large patient information A large number of patient information files cannot be received while Console Application is up and running Therefore perform the following procedure when importing a large number of patient information files at the time of system installation 1 Terminate Console Application 2 Send the patient information files from the ordering device to Console where Console application has been terminated 3 Start up Console The patient information files transferred in step 2 above are imported to Console after it starts up 5 7 Caution smaller time out value for PPS connection disabling operation The study list of Console may be locked which disables operations if the connection to PPS is not established due to a line
78. on Parameter Type 0 Cancel 1 for CR 2 for GOS 3 for aSe 4 for CSI 6 The selected suite of menu DB and parameter files will be installed 10 3 Cautions Do not select the options for GOS a Se Csl in the installation menu Use of the parameter types for GOS a Se Csl other than CR is not guaranteed as the values are only for the purpose of research and development 10 4 Information The default parameter of XconParam mdb installed when 2 Install DR Console Application is selected in the installer menu of the Console application is the same as the parameter of XconParam mdb that is installed when CR is selected in step 5 above Therefore the XconParam mdb for CR is installed as the default parameter at the time of shipment The values that have been set up in the previous version will be migrated when upgrading Console application software ECN No 2012 E 0291Rev 1 53 53 11 Supporting PROFECT P connection 11 1 Outline V7 0 onward supports the connection to FCR image reader unit FCR PROFECT P 3 models to retrieve the images taken with CR cassettes CR IR 362 model name Speedia CS Plus Japan XG5000 Plus CR IR 363 model name PROFECT CS Plus ClearView CS Plus for US CR IR 368 model name FCR PROFECT ONE Plus ClearView 1 Plus for US Although PROFECT P does not support cassette reading of pantomography size 15cm X 30cm imaging can be performed in 10 x12 size when r
79. ontinued where the message MD30009 left displayed on screen the message MD30009 appears again when ShotSwitch is pressed which disables image retrieve MD30009 The conditions that do not allow an exposure to start have been sent from an external device gt Please check the exposure conditions of the external device The message MD30009 appears when the exposure conditions become inconsistent between CR IR 300CL and CU Provide a notice for users to prevent them from continuing operation on DR ID 300CL when the message MD30009 appears Make the users be informed that it is required to confirm the message and then to click OK to close it in such case 5 16 Supported Version Information for Connected Device The versions of devices which can be connected to DR ID 300CL V7 0 are shown below 1 FCR image reader There is no change from the previous version in the connectable models of the FCR image readers and their versions For PROFECT P which is to be supported from V7 0 the following versions are supported FCR PROFECT P V4 0 2 Control Unit The following control units can be connected with V7 0 MC V3 6 or later CU V3 7 or later FDR AcSelerate CALNEO U However in case of AcSelerate Ill connection CU V4 1 or later 3 PPU Tomosynthesis Application Software which can be connected to V7 0 are V1 2 or later 6 Limitations The DR ID 300CL Application Software V7 0 has the following operational limitations Ope
80. p RegMarkerBmp csv 5 Confirm the automatic marker setting There are two types of the default settings for automatic marker connection for the case of newly installed system for Japanese and for other language The contents are as follows lt Japanese gt MenuCode BitmapFilePath FCR0329 0000 L MAMMOGRAPHY CC Left breast CC 84 LCC bmp FCR0329 0001 R MAMMOGRAPHY CC Right breast CC 83 RCC bmp FCR0339 0000 FCR0339 0001 FCR0339 0007 FOR0339 0003 lt Other language gt MenuCode FCR0308 0000 MAMMOGRAPHY co US fsatocomo O O FCR0308 0001 RIMAMMOGRAPHY CO US ea Rocom SSCS FCR0318 0000 L MAMMOGRAPHY MLO US es LMLObmp FCR0918 0001 RIMAMMOGRAPHY MLO US er RMLobm FCR0349 0000 L MAMMOGRAPHY C eatocom SS FCR0349 0001 RMAMMOGRAPHY cC JeaRocom SSS FCR0359 0000 L MAMMOGRAPHY MLO fee LMLObmp FCR0959 0001 RIMAMMOGRAPHY MIO e7RMLosme FOR0359 0002 LMAMMOGRAPHYML eci FOR0359 0003 RMAMMOGRAPHY ML_ Jesi The definitions of automatic marker file connections for the US will be installed if 2 English U S is selected in the installer menu 3 Install Parameter Files ECN No 2012 E 0291Rev 1 41 41 lt USA gt MenuCode BitmapFilePath FCR0308 0000 LCC 84 LCC bmp FCR0308 0001 RCC 83 RCC bmp FCR0318 0000 88_LMLO bmp 8 FCR0318 0001 7_RMLO bmp FCR0328 0000 8C_LML bmp FCR0328 0001 8B_RML bmp Caution Automatic marker setting and marker files The marker files
81. p csv 4 Set up automatic markers In the case of version upgrade the previous automatic marker settings will be migrated Set up the automatic markers for mammography if necessary 5 5 3 User Utility Settings None 5 6 Effects on the other functions Limitations on connection to other equipments Console Advance cannot be connected to the following equipments DR mammography systems FDR MS 1000 FDR MS 2000 FDR MS 2500 CR IR 347 Model name FCR 5000MA ECN No 2012 E 0291Rev 1 42 42 5 7 Cautions Mi Importing data from media CR Console CR AWS and DR AWS cannot import the data in the Fuji local format that is in the media created with Console Advance e DX Console cannot import the data in the media created with DR AWS Import data only between the Consoles on which the same version is running Data cannot be imported if the modality settings mammography in Console and of the data are inconsistent It turns to an error even the media list indicates the media ECN No 2012 E 0291Rev 1 43 43 6 Improvement in operatability of tomosynthesis 6 1 Outline V7 0 improves the following operatabilities in tomosynthesis view Image display speed supporting reduced images in 1 2 size to speed up tiling and stack forwarding display Reconstruction condition setup Changes have been made in the contents of settings and display in an easy to understand manner 6 2 Option key Installation of DR ID 300CL Tomosynthesis Key
82. play it Li Network Connections Control Panel Network and Internet Network Connections File Edit view Tools Advanced Help Organize Operator Assisted Dialing Remote Access Preferences hi Local Area Conr Bridge Connections cal Area Connection 2 A Unidentified ne identified network Ge Intel R 825 IR Gigabit CT Desktop Adapter 4 In Connections list and Bindings for xxx list xxx represents the connection name set up to display the connections in descending order from the highest priority at the top Select the protocols to move upward or downward in the lists and move them using arrow buttons next to the lists x Adapters and Bindings Provider Order Connections are listed in the order in which they are accessed by Connections Local Area Connection i Local Area Connection 2 HEJ Remote Access connections Eat Ee Bindings for Local Area Connection mi File and Printer Sharing for Microsoft Networks wi Intemet Protocol Version 4 TCP IP v4 wi Intemet Protocol Version 6 TCP IPv6 1E Client for Microsoft Networks i Intemet Protocol Version 4 TCP APv4 wi Intemet Protocol Version 6 TCP IPv6 Eal ECN No 2012 E 0291Rev 1 25 39 5 Click OK to close the window Cautions concerning LAN connection Do not switch LAN cables local network for image transfer and in hospital network e For the case of mobile PC Refer to the Service Manual a
83. press the lt Enter gt key Select IIP in the Programs and Features window The Console is uninstalled The system returns to the setup menu Enter 2 and press the lt Enter gt key When the Welcome to the InstallShield for IIP window appears click the Next button When the Ready to Install the Program window appears click the Install button When the InstallShield Wizard Completed window appears click the Finish button The system returns to the setup menu 16 For the systems in which the precise enlargement software has been installed install the precise enlargement software Enter 60 and press the lt Enter gt key The following steps are the same as for V4 0 Firewall settings are not required when installing 17 For institutions where the users are using the free layout print software install the free layout print software Enter 65 and press the lt Enter gt key The following steps are the same as for V6 0 Refer to the Service manual Installation Appendix AppxIN Appendix 30 Free Layout Print 18 The system returns to the setup menu Enter 0 and press the lt Enter gt key ECN No 2012 E 0291Rev 1 6 39 19 Restore Overlay Setting File manually which was backed up into the directory where the file had originally been stored in step 5 20 V7 0 enables LUT setup for the primary monitor and the secondary monitor separately Set up the LUT in the Service Utility if t
84. ptor Only a single Item shall be permitted in this Sequence gt Code Value 0008 0100 1C Required if a sequence item is ALWAYS USER present gt Coding 0008 0102 1C Required if a sequence item is ALWAYS USER Scheme present Designator 0008 0103 1C Required if a sequence item is ANAP USER present Required if the value of Coding Scheme Designator 0008 0102 is not sufficient to identify the Code Value 0008 0100 unambiguously gt Code 0008 0104 1C Required if a sequence item is ALWAYS USER Meaning present gt View Modifier 0054 0222 2 iew modifier VNAP USER Code Zero or more Items may be included Sequence asa in this Sequence gt gt Code Value 0008 0100 Required if a sequence item is ANAP USER present gt gt Coding 0008 0102 1C Required if a sequence item is ANAP USER Scheme present Designator 0008 0103 1C Required if a sequence item is ANAP USER present Required if the value of Coding Scheme Designator 0008 0102 is not sufficient to identify the Code Value 0008 0100 unambiguously gt gt Code 0008 0104 1C Required if a sequence item is ANAP USER Meaning present ECN No 2012 E 0291Rev 1 73 73 OTABLE 8 1 21 DX POSITIONING MODULE OF CREATED SOP INSTANCES following contents have been added and changed PRINTED IN BLUE Se Lie se Se Dicom Attribute Description Presence of Value Positioner 0018 1508 Defined Terms VNAP Type CARM COLUMN When CR or DX i
85. r the mis exposed image comment function 1 Start up the User Utility 2 Store the mis exposure image log or exposure result log using the exposure result log storage function 3 Terminate the User Utility Terminate the User Utility while holding the lt Shift gt key to terminate only the User Utility and not to restart Console 10 11 12 13 14 15 ECN No 2012 E 0291Rev 1 5 39 For institution where the users not using the exposure result data file output function or the mis exposed image comment function 1 Terminate Console Advance Terminate the Console application while holding the lt Shift gt key to terminate only the Console application When FUJIFILM task remains on the task bar right click the task and select End to terminate it After the termination wait around 5 seconds and then perform the next step DeConsole Application User Utility Application End cers EY es BE Gy cy 1504 m When the precise enlargement software has been installed the overlay information will not be automatically migrated Therefore back up the following file manually onto for example the Desktop C Program Files Fujifilm Cooper Config EchoNotelnfoDef xml When the precise enlargement software has been installed uninstall the precise enlargement software according to the Service Manual Installation Appendix AppxIN Appendix 7 Uninstallation of AP 7 Precise Enlargement Software Note As describe
86. rational limitations In clustering images cannot be output to media during the integrated output processing Do not output images to removable media during the integrated output processing During the distributed output processing images can be output to media within Console ECN No 2012 E 0291Rev 1 11 39 No Operational limitations 2 In clustering the study information may not be obtained If the study information cannot be obtained during the operation confirmation after setup start up C Windows System32 drivers etc hosts with the text editor At the end of the file add the IP address and host name of Console with which the study information is shared overwrite and save the hosts Enter a single byte space between the IP address and host name gt 27 To FREE sO FETI LTH i Copyright Cc 1993 2009 Microsoft Corp i This is a sample HOSTS file used by Microsett TCP IP tor Windows This tile contains the mappings ot IF addresses to host names Each entry should be kept on an individual line The IP address should be ds in the first column followed by the corresponding host name The IP address and the host name should be separated by at least one space dana In this example the following 3 Consoles are i lines or following the machine name del registered pe seca 172 16 2 80 CSL H 102 54 94 97 rhino acme com 172 16 2 81 CSL B 38 25 63 10 x Acme com 172 16 2 9
87. receives images only from the selected DR cassette while the high sensitivity mode is on the dialog box is on the screen lt Behavior in case the high sensitivity mode is timed out gt Console behaves in the following two ways if the high sensitivity mode is over without receiving images from the selected DR cassette 1 lt receives a blank image according to MPM code refer to 4 Image acquisition without exposure under the condition where automatic X ray detector is activated for details 2 A warning message appears without receiving an image MD11030 Image not acquired due to Acquisition period timed out or exposure not detectable 3 4 Settings 3 4 1 Service Utility Settings Set up the following items in the Service Utility ECN No 2012 E 0291Rev 1 28 39 Setup Configuration Item SYSTEM CONFIG 5 CSL IDT FUNCTION Sa Nato PE og FN TT E 318 Use X ray Free Operation No Enabling Disabling X ray Yes Automatic Detection Operation function mei Use X free High Sensitive Mode Yes Enabling Disabling the high No sensitivity mode for DR cassette al Time out Value in High Sensitive Mode 30 Time out value for the high The value range is 5 60 sensitivity mode sec 354 MPM Code for QC Lag Image 091E Console receives a blank image Multiple values can be input by _ after the time for the high separating them by commas sensitivity mode is over in the case of selected MPM code 3 4 2 User Utility
88. rted application software upgrade to V7 0 or later may have been failed Confirm if the upgrade has been completed properly Terminate Service Utility User Utility or Console if they are running Close XconParam mdb if it is open If the case is other than above restart the PC If the error occurs even after the PC is restarted application software upgrade to V7 0 or later may have been failed Confirm if the upgrade has been completed properly The same study menu code exists Change the study code in the User Utility Refer to additional menu list for additional menus The same exposure menu code exists Change the exposure menu code in the User Utility Refer to additional menu list for additional menus Correct the error according to corresponding error correction procedure from No 1 to 6 above if this message appears after either error message above from No 1 to 6 appeared If the case is other than above restart the PC If the error occurs even after the PC is restarted application software upgrade to V7 0 or later may have been failed Confirm if the upgrade has been completed properly Correct the error according to corresponding error correction procedure from No 1 to 6 above if this message appears after either error message above from No 1 to 6 appeared If the case is other than above restart the PC If the error occurs even after the PC is restarted application software upgrade to V7
89. s H Universal Serial Bus controllers 20 Select the Driver tab to ensure that the driver version has been updated to 11 17 27 0 Intel R Gigabit CT Desktop Adapter Properties General Link Speed Advanced Power Management Teaming VLANs Boot Options Driver Details Resources Aju Intel R Gigabit CT Desktop Adapter a To view details about the driver files To update the driver software forthis device If the device fails after updating the driver roll back to the previously installed driver Disable Disables the selected device Uninsali To uninstall the driver Advanced 21 22 23 24 Close the properties window Close the device manager window Remove the Option NIC Board Driver CD from DVD drive Restart the PC i _ x y S ECN No 2012 E 0291Rev 1 22 39 Olnstalling PWLA8391GTL PCI board 1 Shut down the PC and remove all the cables connected to the PC 2 Remove the cover of the PC 3 Turn up the card hold latch to remove the filler bracket placed in the card slot opening of unused PCI card Insert the board into the unused PCI card slot Turn down the cardholder latch to fasten PCI board Put the cover back on the PC Attach all the cables removed in step 1 above Connectthe extended NIC to in hospital network and on board NIC to local network for image transfer Turn on the PC Setting up IP address for extended NIC 1 Openthe
90. s used for Modality MEMORIA 0008 0060 value is PANORAMIC CEPHALOSTAT NONE or RIGID NONE COLUMN When MG is used for Modality 0008 0060 value is MAMMOGRAPHIC The average thickness in mm of the body part examined when compressed if compression has been applied during exposure Body Part 0018 11A0 Thickness Compression 0018 11A2 Force OTABLE 8 1 23 X RAY ACQUISITION DOSE MODULE OF CREATED SOP INSTANCES following a have been added Armate tag Dicom Attribute Description Presence of Value Body Part 0018 11A0 The average thickness in mm of the ANAP Thickness body part examined when compressed if compression has been applied during exposure The compression force applied to the body part during exposure measured in Newtons Organ Dose 0040 0316 Average organ dose value measured in dGy during the acquisition of this image ECN No 2012 E 0291Rev 1 74 74 OTABLE 8 1 33 SR DOCUMENT GENERAL MODULE OF CREATED X RAY RADIATION DOSE SR SOP INSTANCES following contents have been deleted _ Wane 28 eee Dicom Attribute Description Presence of Value iH ST AF OTABLE 8 1 34 SR DOCUMENT CONTENT MODULE OF CREATED SOP INSTANCES following contents have been added ee Tag Type Dicom Attribute Description Presence of Value Source Include Document Content Macro TABLE 8 1 34 with a Value Type 0040 A040 of CONTAINER Include Document Relationship Macro TABLE 8 1 35
91. s of Exposure _uAs will be set to ReserveCode1 Refer to ECN No 2011 E 0364 DR ID 300CL V6 1 ECN Appendix Z Correction of Errors Found in the Field for the details of countermeasures for this error Note however that it is not required for institutions where CopyReserveCode1FromMicroAs bat has already been implemented at the time of upgrading the application software to this version V6 0 gt V6 1 Note 5 Exposure menus for mammography have been added to DR ID 300CL from V7 0 onward Operation of console without the exposure menus for mammography will not be supported For this reason it is necessary to add the exposure menus for mammography even for the systems without mammography function Note 6 Manual installation of the markers for mammography is required when using mammography function on V7 0 or later Refer to Appendix A Supporting CR mammography of this ECN for details 4 2 Upgrading Installation 1 Startup the PC 2 After the Console has started up confirm that no studies are left in the Waiting study Waiting QA or Finish QA tab Studies in the Waiting study tab Finish or delete the studies Studies in the Waiting QA tab Finish QA Studies in the Finish QA tab Output the studies or delete the output cues 3 Perform the following procedures depending on the operational conditions of institutions For institutions where the users are using the exposure result data file output function o
92. s relevant cautions are the same as existing ones 2 4 2 Service Utility Settings The setting to display not to display the dialog during calibration can be switched in the following item Setup Configuration Item SYSTEM CONFIG 5 CSL IDT FUNCTION Area Default value 348 Display Calibration Dialog Displaying Not displaying dialog message during calibration 2 4 3 User Utility Settings None 2 5 Effects on the Other Functions None 2 6 Cautions As for other limitations refer to the specifications of MC application ECN No 2012 E 0291Rev 1 26 39 3 Supporting high sensitivity mode of automatic X ray detector 3 1 Outline lt Supporting high sensitivity mode gt There was a possibility that DR cassette would fail to detect X ray when making exposures on patients who have thick body in the case of using automatic X ray detector function To prevent this the mechanism that the user s operation increases sensitivity temporarily for DR cassette to detect X ray is incorporated in this version onward As a result exposures using automatic X ray detector function can be made regardless of body thickness because it enables DR cassette to detect X ray penetrating objects even though the energy of X ray is faint 3 2 Option key None 3 3 Details lt Precondition for connected DR cassette gt The connected DR cassette supports this function MC V4 0 or later lt Conditions for using the high sensitivity mode gt The hi
93. sferred with PrivateCRStorage after the density level was adjusted in Console Advance SIL values adjusted images Now GA GS adjust images Access method to DB has been revised Data files cannot be imported using the Simple Ordering Function in Console Advance if they do not have lt Format gt and lt Handle gt information The program has been revised to enable data file import without lt Format gt and lt Handle gt information for the case of the patient information linkage Retry processing to access to DB has been revised Application freezes if the stitching button is pressed while images are being input to the stitching menu The program has been revised to prevent freeze O Future date cannot be input to the study date to search for on MWM connection BC N VI D OO The program has been revised to enable future date input Negative values cannot be specified for area margin of shuttering processing The range has been revised to 20 to 20 System error occurs while the application is being started up a restart activates the application The error occurred when the information of no option was written in the event log The program has been revised not to write unnecessary log The IP cannot be registered when a menu is deleted during processing on FCR5000 The program has been revised not to generate inconsistency Retransmission processing was repeated in respo
94. te CR Storage for DICOM Storage SOP Class E Cautions Do not change the modality setup once operation is initiated one or more studies are created on Console Initializing the image DB is required when changing the modality setup and modality setup for mammography 5 4 2 PEM Processing BM Enable the functionality The following system configuration specifies whether Console performs PEM processing on the displayed image on the monitor or not Note however that it supports 20 lines mm images only Setup Configuration Item SYSTEM CONFIG 3 QA FUNCTION Area Default value Pem Processing in the case Yes Specifying whether or not to perform PEM of Magnify Display processing on and ultra high density image when it is magnified and displayed for CR only Also set up 1 Hq Image File to No 18 Image File Type For Magnify Display E Cautions Do not perform PEM processing on DR images Therefore PEM parameter cannot be set up for DR do not display it on the monitor Fix Single 1 image for PEM it applies single PEM parameter to L R and 2 in the figure below will be inactivated in the case of L 2 images for left and R 2 images for right ECN No 2012 E 0291Rev 1 34 39 Image Position Image Processing Left Image on 2image Output Right Image on 2image Output OFF OFF OFF e ON OF e ON 1 image Output DRC TAS i OFF aie 1 ON OFF for PEM
95. tion of UT The text shall be interpreted as specified by Specific Character Set 0008 0005 if present in the SOP Common Module Note The text may contain single or multibyte characters and use code extension techniques as described in PS 3 5 if permitted by the values of Specific Character Set 0008 0005 ECN No 2012 E 0291Rev 1 76 76 she Dicom Attribute Description Presence of Value Source DateTime 0040 A120 1C This is the value of the Content ltem ANAP AUTO Required if Value Type 0040 A040 is DATETIME C UID 0040 A124 1 This is the value of the Content Item ANAP AUTO Required if Value Type 0040 A040 is UIDREF Include Numeric Measurement Macro TABLE 8 1 36 if and only if Value Type 0040 A040 is NUM Include Code Macro TABLE 8 1 37 if and only if Value Type 0040 A040 is CODE Include Image Reference Macro TABLE 8 1 38 if and only if Value Type 0040 A040 is IMAGE Include Container Macro TABLE 8 1 39 if and only if Value Type 0040 A040 is CONTAINER OTABLE 8 1 36 DOCUMENT RELATIONSHIP MACRO ATTRIBUTES following contents have been added pa Dicom Attribute Description Presence of Value Source Observation 0040 A032 1C The date and time on which this ALWAYS AUTO DateTime Content Item was completed For the purpose of recording measurements or logging events completion time is defined as the time of data acquisition of the measurement or the time of occurrence of the event