1. Wiring diagrams can be found on the motor nameplate or on the motor electrical box Verify the incoming voltage and that the motor has been properly wired prior to connecting it to the machine 4 Verify proper rotation of the blower motor It will be necessary to view the blower wheel from the blower exhaust on the SM series unit to verify the rotation Proper rotation is marked on the motor housing The blower wheel should be rotating clockwise when viewed from the motor end of the wheel Counterclock wise from the blower inlet cone side of the wheel If opposite rotation is experienced see Figure 2 for directions to switch rotation NOTE A motor starter with overload protection must be provided by the User Thermal overload heaters are installed in the external motor starter Consult the starter manufacturer for recommended heater size for the installed motor WARNING Permanent damage to the motor will be sustained if connected to voltages other than the normal operating voltage for which the unit is pre wired SECTION 3 Installation continued Low Voltage High Voltage Low Voltage High Voltage 6 _ 6 9 _ 9 8 H 9 8 7 4 6 2 Gm 3 St 1 4 Line Line Line Line Interchange any two line wires to reverse rotation to change rotation flip 5 amp 8 3 Phase Single Phase Figure 2 Wire Connection Diagram Minihelic Gauge 1 The Minihelic gauge is typically
2. This module is typically mounted after the 3 stage filter module and before the blower module Optional Equipment Mounting Brackets amp stands Drain Bottles Plenum Kit Silencer Hose Kits w Collars Leg Kit SECTION 2 Applications General 1 Mist The SM series collectors are primarily designed for the capture and removal of mist contaminants from a wide variety of manufacturing processes The standard SM series collector is typically machine mounted or ceiling hung with an bottom pan w collar and consists of a 3 stage filtration cabinet and a motor blower housing The SM series collector can also be wall mounted with optional bracket A HEPA module for removal of secondary smoke contaminants is available on the SMH 12 Unit The SM SMH 12 series collectors can also be floor mounted with an optional leg kit inlet plenum Models Model codes are utilized to identify the various unit configurations available There are three standard models available the SM 5 SM 12 and the SMH 12 The SM stands for Small Media and the 5 amp 12 represent the nominal airflow of 500 and 1200 CFM The SM 5 series collector has only one motor blower configuration which is 2 horsepower The SM 12 has two motor blower configurations the 1 horsepower motor is standard and a 2 horsepower motor is available for derated airflow applications The SMH12 uses a 1 1 2 Horsepower motor blower Bottom Pan wi Collar amp Inlet Plenum Bottom Pans wi collar
3. ALR Control Systems Installation amp Service Manual for Small Media Collectors Models SM 5 SM 12 SMH 12 February 27 2003 Table of Contents DISC IANS E 3 WIIG le WEE 4 Description amp Operation EE 4 Optlonal Gel Ten EE 5 Applications General wcrcccs seis cca reecus was canty verteca ad daeawn ced vewcevvesiuns Gevevnce Medaiteule 5 e GU er EE 6 Installation continued WEE 7 Figure 1 Typical Drain Installation cccccsceeceeeeceeeeeeeeeeeeeeeeeeeeeeeaeeeeeeeeees 7 Installation een e WEE 8 Installation continued EE 9 Figure 2 Wire Connection Diagram cccsseeceeeeceeeeeeeeeeeeeeneeeeeeeesaeeneeeeeees 9 Ordering Replacement Parts Au 10 Oe Een Te 11 Maintenance continued uk 12 Figure 3 Direct Drive Plug Fan Fan Alignment aaaannnneennnnnnnnnnnnne neren 13 eeler leede Le EE 13 SO SCHIICATONS cecina e AEE EE a E EEEE EEEE EE 14 Specifications continued ceisiicccsscdtvessacee descavdsaeseccecssavadsecsdesdunvaleh deh ged Ne gege 15 Ein ee WE e EE 16 Disclaimer Although instructions and recommendations are included for installation of your Small Media Collector the manufacturer does not assume responsibility for the installation of this equipment nor shall he be held liable for direct or consequential damages resulting from improper installation application maintenance or use The immense variety of contaminants make it impossible to list all of the potential hazards that may be enco
4. a standard 3 stage filtration module and a blower module The SM collectors typically house wet filter stages that include a 4 inch cleanable Chevron Impinger a 1 cleanable metal mesh filter and a 12 inch deep box style 95 ASHRAE efficient dispos able fiberglass filter The bottom pan is designed to allow the SM collector to be mounted to the top of a machine enclosure or when the unit is ceiling hung a flex hose or duct can be attached to the bottom inlet and then be connected to a collar on the machine enclo sure Units equipped with the bottom pan do not require a seperate drain hose as fluids will drain back through the collar or collar and flex hose or duct into the machine The inlet plenum option on the SM 12 has a drain fitting for removal of the coolant and a 10 foot drain hose to transport the coolant to either the sump of the machine or a suitable container Also included as standard is a blower module which is typically mounted on the clean air side of the filters A standard blower module consists of a direct drive backward inclined fan and an electric drive motor The standard fan motor combination for the SM 5 is 2 horsepower and a 1 horsepower is standard on the SM 12 The SMH 12 collector the SM12 unit described above with the addition of a HEPA Mod ule and larger 1 1 2 horsepower fan motor combination The HEPA module houses a standard HEPA filter rated at 99 97 efficient at 0 3 microns other efficiencies avail able
5. for SM 12 Units 1002 06 On Off Switch 1206 01 k CH SECTION 5 Maintenance Operation amp Maintenance Lubrication or other routine periodic preventive maintenance is not required All that is needed is an occasional check of fasteners and a general visual check of the unit to make sure that nothing has gone wrong Periodic replacement of the filters is required when necessary Dispose of filters in accordance with local standards and procedures for the material collected Filter Replacement for the SM Series Collectors Disconnect and lockout electrical power to the motor before servicing Access to all the filters is accomplished by opening the outside removable door on the three stage media module by turning the wing knobs enough to lift the door off the threaded studs 1 Impinger Replacement on SM collectors The 4 inch impinger is the first stage of the three stage media module Once the outside filter access door is opened the impinger can be removed by sliding the impinger out The aluminum impinger is cleanable and can be washed with mild detergent or solvent Aluminum mesh filter replacement on SM collectors The 1 inch aluminum mesh filter is the second stage of the three stage media module This filter will be accessible once the lift off door is removed and mesh filter can be slid out of the cabinet The cleanable aluminum mesh filter can be washed with mild detergent or solvent but it is important to be gentle wh
6. g to local requirements All data and dimensions in this manual have been thoroughly checked however we cannot assume responsibility for possible errors or omissions We reserve the right to change designs and or specifications without notice WARNING Failure to comply fully with the following instructions and local code requirements may increase your risk of physical injury due to fire explosion or electrical shock SECTION 1 Uncrating 1 Remove banding and cardboard shipping carton and packing 2 The SM series unit is shipped in the vertical position using the shipping angle brackets to bolt the unit to the skid The four legs if supplied and inlet plenum are typically shipped on the same skid Mounting hardware and gasket material is included in labeled boxes for mounting be sure to check all boxes before discarding 3 Inspect the exterior of the unit and accessories for shipping damage or shortages that may not have been noticed or recorded when the shipment was initially received you have 30 days to notify AER Control Systems LLC of any discrepencies Contact the shipping company if any damage or shortages have occurred Description amp Operation The standard SM series collectors can either be machine mounted ceiling hung wall mounted or floor mounted with an optional inlet plenum leg kit only on the SM 12 series The SM collectors consist of either an bottom pan w collar SM 5 amp SM 12 or plenum SM 12
7. ile washing Observe the direction of flow indication on the new replacement filter Insert the filter with this arrow facing the blower module direction Box Style Filter Replacement on SM collectors The box style filter is the third stage of the three stage media module This filter can be accessed once the lift off door is removed the box filter can be slid out of the cabinet Place filter ina plastic bag or dispose of in accordance to local requirements Observe the direction of flow indication on the filter Insert the filter with this arrow facing the blower direction 11 SECTION 5 Maintenance continued 4 5 1 HEPA Filter Inspection and Replacement on SMH Collector a b Open the access doors and rotate the yellow handles down on both sides of the Cam Clamps Carefully remove the filter by prying it away from the sealing sur face toward the Cam Clamps Inspect the filter for damage If ripped or visibly damaged discard Unpack a new HEPA and inspect the sealing surface Carefully slide it into the cabinet with the gasket toward the metal seal edge Rotate the yellow Cam Clamps up and to lift and seal HEPA in cabinet make sure the gasket is in full contact with the metal seal edge of the cabinet Cleaning and Inspection of Cabinet After dirty components have been removed inspect cabinet interior Remove foreign material wipe interior and clean all filter seating surfaces Direct Drive B
8. improper installation or other causes not arising from defects in original materials or workmanship Any part that is determined to be defective in material or workmanship and returned to an AER Control Systems LLC distributor or authorized service facility as AER Control Systems LLC designates shipping costs prepaid will be as the exclusive remedy repaired or replaced at AER Control Systems LLC s option AER Control Systems LLC shall not be liable for any incidental or consequential cost expenses or damages resulting from any failure defect or malfunction of this product liability is expressly disclaimed AER Control Sys tems LLC s liability in all events is limited to and will not exceed the purchase price of the product Title and risk of loss pass to the buyer on delivery to the common carrier If a product is damaged in transit the recipient MUST make note of the damage upon receipt of the product and file a claim with the carrier AER Control Systems LLC will make a good faith effort for prompt correction or other adjustment with respect to any product that proves to be defective within the warranty period Collection of combustible or explosive materials and collection on flame or spark generat ing operation any require specific system configurations contact AER Control Systems LLC s Applications Engineering Department for questions and or design assistance The combined collection of combustible or explosive materials and con
9. k The width dimension is from one side to the other side AER Control Model Systems Box Filter Type SM 12 SMH 12 SM Series Module Specification Dimensions SM Series Module Prefilter Inter Final Main Gre Depth Height Width Impinger Aluminum Mesh P 12x20x4 WEEN Box Filter 23 sq ft 21 39 19 Impinger Aluminum Mesh HEPA Filter P SMH 12 4x244 1x12x20 Box Filter 58 sq f 22x22x12 29 60 26 includes bottom inlet collar 14 Motor HP Specifications continued MOTOR SPECIFICATIONS Speed RPM Voltage Phase Frame NEMA Power Factor Start Current Amps 60 Hz 60 Hz Service Factor Duty Cycle Bearing Grease Specification 3450 115 230 21 10 5 7 3 6 3 5 TEFC Exxon POLYREX EM UL and CSA Approved 115 230 38 19 11 8 6 1 5 9 POLYREX EM UL and CSA Approved 15 115 230 Exxon POLYREX EM UL and CSA Approved AER Control Systems Limited Warranty AER Control Systems LLC warrants all products sold only to purchasers for use in busi ness or for resale against defects in workmanship or materials under normal use for one 1 year after the date of purchase from AER Control Systems LLC Misapplication of the product decomposition by reaction or chemical action and wear caused by abrasion will not constitute or be considered as a defect Warranty is void if the product has been subject to damage unreasonable use neglect improper service
10. lower Wheel and Inlet Cone Disconnect and lockout electrical power to the motor before servicing Access to replace the motor and or blower wheel will require removal of the top cover motor and blower assembly Remove the fasteners that attach the top cover motor and blower assembly to the cabinet and lift the entire assembly off of the unit Reverse this procedure to install the assembly back onto the unit It is very important to maintain the correct inlet cone insertion into the blower wheel inlet There can not be any large air gaps between the top of the cone and the bottom of the blower wheel If a gap occurs then the blower wheel s efficiency is diminished and airflow is reduced There is a curved radius at the blower inlet where the air enters the wheel and the inlet cone is inserted into the wheel The blower wheel should be located so that the top of the inlet cone is at midpoint of the blower wheel s curved inlet radius Checking and adjustment of the wheel to inlet cone alignment can be done without removing the top cover motor and blower assembly Open the filter access door on the filter module directly preceeding the blower assembly and remove the filters for access and adjustment to the inlet cone and blower wheel Standard units are equipped with composite fans and inlet cones however aluminum inlet cones and wheels may be utilized in special applications Reference the following diagram for proper wheel to inlet cone alignmen
11. mounted on the 3 stage media module and measures the pressure drop across the 3 stages of filters If a HEPA module is supplied the same gauge measures the pressure drop across the 3 stages of filters and the HEPA filter The Minihelic gauge has a red needle that indicates the pressure drop reading To zero in the gauge run the collector with clean filters and turn the screw at the bottom face of the gauge to zero This is your starting point with clean filters in place Periodically check the design airflow whether it be weekly or monthly to determine if the filters are dirty Eventually the pressure drop reading will reach a point where there is insufficient airflow to capture the contaminants generated Mark the gauge face with a black marker at the reading on the Minihelic gauge In the future a quick look at the gauge will give you a sense of when the filters will need to be changed In some cases the first or second stage filter could be dirty and the third stage filter box filter is fine To check this scenario pull out the first or second stage filter to see if the design airflow improves If it does then either clean or replace the first or second stage and leave the third filter box filter alone At some point the third stage filter box filter will need to be changed when removal of the first and second stage filters have little or no change on airflow or on the Minhelic gauge reading 9 SECTION 4 Ordering Replacement Parts Info
12. or any other sealant that is suitable with the coolant used The collars can be added before or after the unit is mounted to the inlet plenum DRAIN FITTING Corr oa 1 25 NPT TO 1 25 BARBED 7 ED FITTING Ze Ee Le J J Vv e 1 25 D TUBING a xe X ff Li pete dE NO AE F 7 VK T IF THIS END O j HOSE IS SUBMERGED THEN TRAP NOT REQ D Figure 1 Typical Drain Installation i SECTION 3 Installation continued Electrical 1 Single phase 115V 60HZ units are standard prewired from the factory and include an On Off switch wired to the electric motor with a power cord for single phase power Single phase 230V and three phase units are an option but do not include a switch cord or plug All three phase and 230V single phase units are wired for the input voltage specified on the purchase order 2 Motors used on the SM series collectors are UL recognized and internal wiring is UL rated at 600 volts Input power line protection is required for the motor and electrical components Line load and current requirements are identified on the motor nameplate Unless ordered with the machine the power switch for operating the machine any fusible disconnect motor starter or controller are to be provided by the customer user and located externally to the machine 3 All connections to the non standard units are made at the motor electrical box three phase amp 230V single phase
13. rmation required for prompt delivery of replacement parts will be 1 Model and Serial Number 2 Part Number and Description Contact your local AER Control Systems LLC distributor for replacement parts Use either our toll free telephone number or our website www aercontrolsystem com to obtain the nearest AER Control Systems LLC distributor s name and telephone number 1 866 265 2372 Part Number 1217 01 Description Minihelic Pressure Gauge Miscellaneous Hoses and Clamps 4 x 10 Neoprene Polyester Flexhose 1051 01 6 x 10 Neoprene Polyester Flexhose 1051 02 8 x 10 Neoprene Polyester Flexhose 1051 06 10 x 10 Neoprene Polyester Flexhose 1051 07 Hose Clamp 4 Bridge 1050 10 Hose Clamp 6 Bridge 1050 11 Hose Clamp 8 Bridge 1050 12 Hose Clamp 10 1050 07 Miscellaneous Spare Parts SM 5 Impinger Cell SM50018 10 H10015 01 SM 12 Impinger Cell Miscellaneous Filters XE Box Style Filter 12 x 20 x 12 95 ASHRAE 23sq ft 1036 03 XE Box Style Filter 24 x 24 x 12 95 ASHRAE 58sq ft 1036 04 Aluminum Prefilter 1 x12 x 20 1034 21 6 Pack Aluminum Prefilters 1 x12 x20 1034 22 Aluminum Prefilter 1 x24 x 24 1034 03 6 Pack Aluminum Prefilters 1 x24 x 24 1034 04 1040 16 HEPA Filter 22 x 22 x 12 99 97 3 microns Miscellaneous Motors and Electrical 0 5 HP Motor 1 PH 3450 RPM for SM 5 amp SM 12 Units 1002 01 1 HP Motor 1 PH 3450 RPM for SM 12 Units 1002 03 1 5 HP Motor 1 PH 3450 RPM
14. s are standard with a base unit the bottom pan allows the SM series collector to be mounted to a machine enclosure and provides the air inlet to the bottom of the SM collector Coolant drains out of the SM collector through the collar on the collar plate For ceiling hung installations the bottom pan allows a hose or duct to be attached to the collar and then attached to a collar or hood at the source of the contaminant An inlet plenum option is available on the SM SMH 12 series collectors The inlet plenum comes with a choice of collar sizes size dependent upon airflow and requires a seperate drain hose for fluid drainage A drain fitting is located on the bottom of the plenum to allow the coolant to drain back to the sump of the machine suitable container or drain bottle SECTION 3 Installation Assembly amp Installation SM Series Collectors 1 Standard collectors are shipped without the bottom pan or inlet plenum and leg kit installed mounting hardware and gasketing is included The standard SM series is shipped in the vertical position on the skid using L shaped angled mounting brackets Installation consists of machine mount or ceiling hung with bottom pan wall mount with bracket or floor mount with leg kit only on SM SMH 12 series The same L shaped angled shipping mounting bracket as mentioned above can be used for lifting and to ceiling mount the unit Machine Mounting Machine mounting is easy with the bottom pan one
15. side attaches to the bottom of the SM series collector using supplied hardware and gasketing The collar side of the plate is inserted into a hole cut into the top of a machine enclosure Decide on a location on top of the machine enclosure and use the bottom pan as a template to cut the round hole in the machine enclosure Insert the collar through the hole of the enclosure and screw down the pan to the enclosure Sealant can be applied between the top of the enclosure and the bottom pan if sealing is an issue Apply gasketing supplied to inside lip of the bottom pan and lower SM collector into the pan Fasten collector to pan using hardware supplied and insert bolts through the holes in the bottom pan to the bottom four corners weldnuts of the collector Floor Mounting The leg kit if supplied can be bolted to the unit using the hardware shipped with the unit Once the legs are attached to the SM SMH 12 unit it should be located as close to the pick up source as possible The SM SMH 12 unit with legs should be level and bolted to the floor Ceiling Hung For suspended installations the L shaped angle bracket can be attached to the top of the 3 stage media module and either threaded rod or cable can be used to suspend the unit from the ceiling The bottom pan can be attached to the bottom of the SM series Collector See machine mounting section for bottom pan attachment A Flex hose or duct is attached to the collar on the bottom pan and
16. t 12 FAN WHEEL COMPOSITE FANS ALUMINUM FANS Figure 3 Direct Drive Plug Fan Fan Alignment Troubleshooting Check overload heaters in starter and fuses and Motor fails to start No power to unit replace or reset if necessary Check for proper wire connections to and from the starter and collector Check rotation of blower If running backwards interchange 2 of the 3 input power leads 3 phase motors only S GE a giriyor Replace or clean filters or check filters for blockage Low airflow and or suction OGRE Blower is running backwards Obstruction in ducting Check ducting or hose for blockage Check for or hose dampers in the duct system they may be closed Duct or hose Improper duct design or higher pressure fan resistance too high required ee eet Replace filter Contaminant blowing out of emer collector exhaust Filters are not properly Check seal edge on HEPA Check seals around installed filter ea Gt nie Check for wheel to cone interference Motor blower noise or vibration Motor cooling fan is Adjust motor cooling fan cover so that it does not rub rubbing on cover or hit 13 Specifications The specification chart below will give the important information for each module Overall sizes weight filter area can be figured out by totaling module data The dimensions are taken as if you are facing the access doors on the unit the doors would be the front of the unit and the depth dimension is from the front to the bac
17. taminants from spark or flame generating operations with a common collector or duct system is not recom mended unless special design provisions have been made to the system sparks or flames resulting from such operations may ignite the combustible or explosive material Under no circumstances should anyone be allowed to discard a lighted cigarette other burning materials or refuse into an inlet hood or the duct of the collection system It is the responsibility of the end user to comply with all applicable national state and local fire and safety codes AER Control Systems LLC s liabiltiy for consequential and incidental damage resulting from a fire or explosion is expressly disclaimed Installation of suitable overload protection such as a motor starter according to NEC guidelines is required Failure to provide proper overload protection will void warranty coverage on electrical components in the system Combination motor starters with fusible disconnect packages are available through your local AER Control Systems LLC representative To ensure optimum collector performance always use AER Control Systems LLC replacement filters
18. the other end is attached to a collar or hood at the source of the contaminant Wall Mounting Optional Wall Mount Brackets are available to mount the SM units to a vertical wall or the side of a machine enclosure Before mounting ensure that the wall has suffcient strength to support the SM unit The brackets are attached to the top of the third stage media module and the assembly is fastened to the vertical wall with suitablemounting hardware customer supplied SECTION 3 Installation continued 6 Inlet Plenum The inlet plenum is only available on the SM SMH 12 series collectors the plenum is shipped with a drain fitting and 10 feet of 1 1 4 inch drain hose The drain fitting is typically installed in the bottom of the inlet plenum the drain hose barb is shipped loose and should be installed in the fitting The drain hose slips over the barb fitting and the other end should be submerged in the sump of the machine or container If the end of the drain hose cannot be submerged then a loop should be created with the hose to provide a trap similar to the trap under a household sink An alternative is to attach an air tight drain bottle to the bottom of the inlet plenum two sizes are available as an option from AER Control Systems LLC This is necessary so air is not drawn up through the drain line which would prevent fluid drainage The inlet collars should be attached to the outside of the SM SMH 12 unit using a sealant such as silicone
19. untered with air pollution control systems It is therefore important that the application of the equipment be discussed with an AER Control Systems representative or application engineer prior to use Additionally users should consult and comply with all National and Local Fire Electrical and or other appropriate codes when determining the application location and operation of any air pollution control equipment Collection of combustible or explosive materials and collection on flame or spark generating operations may require specific system configurations contact AER Control Systems LLC Applications Engineering Department for questions and or design assistance The combined collection of combustible or explosive materials and contaminants from spark or flame generating operations with a common collector or duct system is not recom mended unless special design provisions have been made to the system sparks or flames resulting from such operations may ignite the combustible or explosive material Under no circumstances should anyone be allowed to discard a lighted cigarette other burning materials or refuse into an inlet hood or the duct of the collection system It is the responsibility of the end user to comply with all applicable national state and local fire and safety codes This manual should be read completely before attempting Operation or Maintenance of this equipment All work should be performed by qualified personnel accordin