Home

SmarTemp Control fx

image

Contents

1. 4 screws 5 Apply the supplied Heater Off warning sticker in a highly visible location to the drivers area Refer to the example sticker below WARNING SmarTemp Control fx Installation Operation Instructions 6 Observe the Menu Descriptions section for proper menu setup Electrical Connections SmarTemp Connector Pin out Pin Number Description WireColor 1127 24V Ra o Heater Output Black or Gray g TERMINAL INSERT a Diagnostic Blink Code EN SIDEOF CONNECTOR For terminal removal use Molex terminal removal tool P N 11 03 0044 http www molex com Diagnostic Blink Code functionality does not apply to most coolant heaters Refer to the Error Code section for additional information Relay Connection If applicable Heaters requiring a higher amperage ON OFF signal will require a relay to accommodate different specifications If the connected heater requires more than a 1A ON OFF signal to start use the pin out of a standard relay as described below La daaa Battery B power source Fused according to required heater amperage Switched ON OFF signal to heater Component Description Webasto ON Off Button it I Jebasto Rotary Knob Screw Cap LCD Screen j Status Indicator Light s O Selection Button Micro USB Service Port The micro USB service port is not used for Webasto heater diagnostic purposes on SmarTemp
2. Control fx SmarTemp Control fx Installation Operation Instructions LCD Screen Legend Standby Mode Standby Auto TU Standby Manual Day and Time 8 15 2A Day and Time Auto Mode Mann Manual Mode Timers Enabled Auto Mode Current Day Current Time Timer Active Auto Mode Wi Heater ON Runtime Duration Remaining Manual Mode Current Day Current Time Manual Operation Mode nu on Heater ON Runtime Duration Remaining gt 00 59 tH Menu Descriptions Time amp Date Time amp Date allows user to properly set the current date and time User also AM PM has the ability to switch between AM PM and 24 hour format If the 24 hour format is selected the date format will change to dd mm yyyy Two modes are possible Manual Auto mode enables the pre defined timer programs Standard ON OFF functionality is still possible while in this mode Manual Mode allows the heater to be operated via the Webasto button on the SmarTemp Control fx While in Manual Mode all Auto Mode functionality is indefinitely disabled Note While in manual mode the heater will continue to operate based on the pre defined Duration set by the user See Duration for further detail mm dd yyyy Language changes between English Spanish and French English Duration allows user to select heater runtime of the heater Set range Is 60 minutes between 10 120 minutes selectable by 10 minute increments While using Manual Mo
3. de the Duration setting will be used for the runtime of the heater when the Webasto button is pressed Note Setting the Duration run time in the Duration section before setting a timer program will default all new programs to the user defined duration time SmarTemp Control fx Installation Operation Instructions Timer There are 4 heater start up cycles possible 7 days per week Select the day or Calendar the specific timer T1 T4 using the rotary knob and the selection button Fields Empty Once the day time and duration have been entered press the selection button to set A checkmark will confirm the timer has been saved To turn the timer OFF select the timer checkmark and dial the duration down to the OFF position and click the selection button The Skip feature looks similar to timer programming however when a Calendar specific timer program is selected it will update the checkmark to an s for Fields Empty skipped When a program has been skipped it will disable that specific timer program for one cycle 7 day period Preset timer programming will reactivate after this one time skip cycle Note To permanently turn a timer OFF refer to the Timer section LVD LVD Low Voltage Disconnect allows the user to adjust the battery voltage level at which the Webasto SmarTemp Control fx will shut down heater functionality If battery voltage is equal to or less than the threshold selected 0 1v
4. l Jebasto Feel the Drive SmarTemp Control fx Digital Timer Interface Installation Operation Instructions General Thank you for choosing Webasto to meet your heating needs The Webasto SmarTemp Control fx enables you to preset start up cycles of your Webasto heater 7 days a week with 4 individual times each day Operation The Webasto SmarTemp Control fx is controlled using a rotary dial around the outside of the unit to browse through different menu options Simply click the selection button a to make your choice The following sections will define each menu Item and its default setting Compatibility All Coolant Heaters The SmarTemp Control fx has an output of 1A for the heaters ON OFF signal Heaters requiring a higher amperage signal will require a relay to accommodate different specifications See electrical connections for details Note Relay not included Mounting Procedure 1 Find a suitable mounting location on a flat surface if possible in a visible area Note Always install in an area protected from the effects of weather and contamination Use the drilling dimensions to lightly mark the two mounting holes Optional Step To route wire harness through the mounting surface drill a 17mm hole as notated on the drilling dimensions image NOTE Always make sure there are no obstacles behind the mounting location prior to drilling 4 Secure the Webasto SmarTemp Control fx using the two supplied
5. ontrol fx Installation Operation Instructions Technical Information Rated Voltage 12 24V Operating Voltage Range 12V 11 16V 24V 21 32V Low Voltage Disconnect Range 12V 11 12 5V 24V 21 25 5V Operating Temperature 40 185 F 40 85 C Installation Dimensions L x H x D 2 7 x 2 2 x 60 69 4mm x 55 5mm x 15 2mm 62mm 2 7 16 Use this drawing for dimensional reference only This is NOT a Template 8mm 2 167 5mm 3 16 D 17mm 11 16 For a Spanish version of this document scan this QR Code Jebasto Feel the Drive Webasto Thermo amp Comfort N A Inc 15083 North Road Fenton MI 48430 USA Phone 810 593 6000 Fax 810 593 6001 Email info usOwebasto com Internet htto www webasto us htto www techwebasto com Org 9 2014 Rev N A Ver 1 1
6. the heater will not start i e if an 11 5v threshold is selected the heater cannot be started until B has reached 11 7v 12 volt Range between 11v 12 5v 11 4v 24 volt Range between 21v 25 5v 24 2v Error Codes This section will log the last 5 error codes and the date that it was set No Errors Highlight and select an error code for a full description If the heater produces an error code the status indicator lights will flash red and the error will display on the main screen Error codes cannot be reset through the Webasto SmarTemp Control fx Refer to the heater service manual for resetting an error code Note Error code functionality does not apply to most coolant heaters Codes on products with no blink code functionality can still be obtained using the PC Diagnostics test tool Refer to the applicable service manual by visiting www techwebasto com for detailed PC diagnostics information The hour meter logs the operating hours of an active ON signal to the N A heater This does not reflect the true runtime of the heater itself Note For warranty purposes a diagnostic printout is still required where applicable This hour meter is for reference only Default Default allows the user to perform a factory reset of the control settings and N A saved timer program data This displays the firmware version of the Webasto SmarTemp Control fx Installed Version ma Select this to return to the previous screen SmarTemp C

Download Pdf Manuals

image

Related Search

Related Contents

here  DG 150 - Hilti  取扱説明書 パッケージ内容  antorcha mecánica - Victor Technologies  User Manual of PUE 7 indicators  Microsoft Word Viewer - 取扱説明書_N1A011  仕 様 書  Mantenimiento / limpieza UNIBAD Conozca... Póngase en contacto  7 - Frenteknik  Instructions: Zero Turn Mower Cover CAUTION Fitting Installation  