1. INC Eguipment Division RAM C 115 230 VAC USER S MANUAL INSTALLATION OPERATION MAINTENANCE CPAC Equipment Division 2364 Leicester Road P O Box 175 Leicester New York 14481 585 382 3223 585 382 9481 www cpacequipment com 9 03 TABLE OF CONTENTS RECOMMENDATIONS IMPORTANT SAFEGUARDS DESCRIPTION SPECIFICATIONS INSTALLATION General Comments Pump Recalibration CONTROLS General Comments Electronic Controls Control Panel Functions Control Panel figure 1 RECOMMENDED OPERATING CONFIGURATION FLOW ADJUSTING INSTRUCTIONS FOR COMPACT BELLOWS PUMP TROUBLESHOOTING PARTS LIST ELECTRICAL SCHEMATIC DISCLAIMER STATEMENT OF WARRANTY RECOMMENDATIONS General Comments Read the entire instruction manual before installation or operation of the RAM C chemical mixing system It will help you to understand the operation of the system how various sub assemblies work together and the operating seguence of the controls WARNING NEVER ATTEMPT TO PERFORM ANY ELECTRICAL TROUBLESHOOTING ADJUSTMENT S OR SERVICE S UNLESS YOU ARE A QUALIFIED ELECTRICIAN ELECTRONICS TECHNICIAN OR FACTORY TRAINED SERVICE TECHNICIAN IMPORTANT SAFEGUARDS General Comments When using your RAM C chemical mixing system these basic safety precautions should be followed 1 Read and understand all instructions 2 Care must be taken to avoid burns from touching hot parts 3 Do not operate this appliance with a d
2. COMPACT BELLOWS PUMP lllusirated Below CRANK ADJUSTING SCREW 5 16 HEX w SLOT STROKE INDICATOR 5 OF STROKE STROKE SCALE SET SCREW 1 2 BELLOWS S 1 to 1 1 2 BELLOWS 1 Do not attempt to adjust flow while pump is running 2 Clockwise rotation of the adjusting screw increases pump stroke until achieving 100 stroke Do not attempt forced rotation of the adjusting screw after indicator reaches 100 and a bottoming resistance is experienced 3 Counter clockwise rotation of adjusting crew decreases stroke 4 Only eight clockwise revolutions adjust stroke from 0 100 One half inch bellows pump requires four revolutions 5 It is not necessary to loosen set screw NOTE Do not add lubricants to any pump mechanism 11 TROUBLESHOOTING GUIDE Alarm sounds Developer concentrate tank low Refill developer concentrate tank Fixer concentrate tank low Refill fixer concentrate tank Water tank low valve broken Replace valve Water tank low water OFF Turn ON water Fixer Developer holding tank low pump not Check metering pump delivering Low level float switch broken Replace switch Power light does not Unit not plugged in illuminate Unit not turned ON No power to outlet Pumps not delivering Stuck check valve Clean out replace if necessary Pump not primed Prime with water Loose nut on outlet elbow Hand tighten nut Lines plugged Flush with warm water Hose restricted Water not turned ON Broken
3. As long as the switch is held in the UP position the metering pump will operate and the green indicator light will illuminate 3 Fixer Bulk Add Switch This is a momentary switch which activates the developer metering pump to mix additional fixer and pumps it into the front holding tank As long as the switch is held in the UP position the metering pump will operate and the green indicator light will illuminate NOTE Both of the bulk add switches override all other functions of the unit While the unit is functioning normally there should be no need to use these switches If using a bulk add switch be careful not to overfill the front holding tanks 4 Low Level Alarm Switch Each tank is equipped with a low level switch If any tank level fall low enough to activate the switch the red alarm light will flash and a buzzer will sound The low level alarm switch will silence the buzzer for 15 minutes after which time it will sound again if the low level condition is not corrected The red alarm light will continue to flash until the low level condition is corrected CONTROL PANEL RAM C Developer Red LOW Tank Alarm Green Power Green Bulk Lamp ON Lamp Add ON Lamps RAPID ACCESS MIXER cpac Eguipment Division System ON Manual Bulk 15 Minute OFF Switch Add Switches Alarm Mute Switch Figure 1 RAM C Recommended Operating Configuration lt lt Water Inlet Hose FLOW ADJUSTING INSTRUCTIONS FOR
4. 50 60 Hz 350 W Chemical Tanks 10 gallons maximum capacity 6 gallons operating capacity each Dimensions 19 D x 24 1 3 W x 25 3 4 Pump Rates Dev 450 mls min Dev Water 2 000 ml min Fix 450 mls min Fix Water 2 000 ml min Water Supply 16 ft hose with fittings Net Weight 60 Ibs Installation unit is internally preplumbed and is complete with all fittings INSTALLATION General Comments Refer to Figure 2 for installation diagram 1 Remove the RAM C from the shipping container and check for signs of damage such as cracked tanks broken fittings etc Notify the shipping company immediately if any damage exists Remove all packing materials and save Position the system within six feet of a grounded 120 VAC 5 Amp power source The metering pumps are preset to mix at approximately a 4 1 2 1 ratio of water to chemistry This ratio may be changed by recalibrating the pumps Refer to the pump recalibration section below Insert the developer and fixer pump chemistry inlet pipes into the drum or cube of concentrated chemistry Connect the developer and fixer inlets to the processor replenisher pump up to six to the sides of the RAM C Connect the 16 ft water inlet hose to a cold water source Connect the fixer and developer tank overflows to a drain or containment unit as required For the initial start up it is recommended that you mix a batch of chemistry and manually fill the
5. adjustment screw Split bellow Incorrect mixture Check float valve in water tank Clean replace if necessary Water not turned ON Turn ON Improper pump calibration Recailbrate pumps Pumps not delivering Check poppet valves CPAC Equipment Division 2364 Leicester Road P O Box 175 Leicester New York 14481 585 382 3223 585 382 9481 www cpacequipment com Part Number 700050 38 113P2213 703451 01 126B6000C 702508 702509 700606 42 113P2110 19 111P2003 15 143P2011 CPAC Equipment Division 2364 Leicester Road P O Box 175 Leicester New York 14481 585 382 3223 585 382 9481 www cpaceguipment com RAM C PARTS LIST Description Fuse 5A Norm 125V AGC 5 Filter Chem Tank 500 Microns PLC 12 Input 8 Output Pump Mag Drive March 1A MD 1 2 Pump GRI 16003 001 G010 F001 F004 F31 H3 Pump GRI 16002 001 G006 F004 F31 H3 Switch Liq Lvl 10VA LS 3 Valve Float with Brass Body and SS Seat RM66 Fuse 1 Amp Bussman P UL LS 7 Level Switch Type 3 125748 CYD BL 79 22 118 9 dWid NHld3u A30 dW ld NIIAJ XIJ dWid XII 581534 A30 CYD YB 00 XI3 C19 81 38 CY 8D 38 Y9 BI T8 Sa JM VI ND 3813 YS 43404 Lo 01049 cmm WA SII 500233 14 EVERY EFFORT HAS BEEN MADE TO INSURE THE COMPLETE ACCURACY OF THE CONTENTS OF THIS MANUAL NO LlABILITY ARISING FROM ITS USE HOWEV
6. developer and fixer holding tanks This will prevent unnecessary strain on the metering pumps during the initial start up period CAUTION Use hose clamps on all connections to prevent leaks Pump Recalibration 1 Disconnect the outlets of the two or three bellows of the pump requiring calibration Place the concentrate inlet tube of the metering pump into a bucket of water For fix with hardener place the inlet tube for the hardener into the bucket of water also Run tubes from the outlets of the pump bellows into an empty bucket Run the pump until all the lines are primed then stop the pump The developer metering pump has two bellows 1 2 bellows which pump 2 liters minute at 100 setting and 1 1 bellows which pumps 450 mls minute at 100 setting The fixer metering pump contains three bellows 1 2 bellow 1 1 bellow and 1 1 2 bellow which pumps 45 mls minute at 100 for the hardener Place the outlet for the 2 water bellows into a graduated cylinder and run the pump for 15 seconds Multiply this by 4 to obtain the flow rate per minute Repeat three times and compare the results Discard the liquid in the graduate and measure the 1 bellows Divide the two numbers to obtain the mix ratio Adjust one of the bellows as needed and remeasure its output as in steps 5 and 6 Consult your chemistry supplier for the appropriate ratio Example Ifa 5 1 ratio of water to chemistry is required set the
7. water bellows at 100 and adjust the chemistry bellows output to 400 mls minute It is recommended to operate the bellows as close to 100 as possible while still keeping the desired ratio If the ratio is less than 4 1 2 1 decrease the water bellows If the ratio is greater than 4 1 2 1 decrease the chemistry bellows 9 11 The third bellows on the fixer pump is a 1 2 bellows used for adding hardener This bellows has a maximum rate of flow of 45 mls minute Consult your chemistry manufacturer for the appropriate amount of hardener to be added to the fixer One fluid ounce equals 29 57 mls Drain the water from the pump concentrate inlet tube before inserting it into the concentrate tank Also drain the hardener line before using it Reattach the pump outlets to the fittings to the original locations NOTE For best performance of the metering pump operate the bellows between 50 to 100 CONTROLS General Comments Electronic Controls The RAM C is controlled by a state of the art microprocessor based Programmable Logic Controller PLC This PLC is versatile and able to be updated easily by just changing the software program The PLC uses the input from the float switches and the manual switches then provides control for all the pumps and the low level alarm The PLC keeps the tanks full by monitoring the high level switches and makes sure the tanks don t run dry by monitoring the low level switches and sounding the
8. 5 382 3223
9. ER CAN BE ACCEPTED BY THE COMPANY WHO RESERVES THE RIGHT WITHOUT PRIOR NOTICE TO ALTER THE SPECIFICATIONS CONSTRUCTION OR CONTENT OF ITS EOUIPMENT AT THE COMPANY S OWN DISCRETION Statement of Warranty All equipment is manufactured to exacting standards and has been tested and inspected for proper workmanship and performance before shipping Any parts which are defective will be repaired or replaced within a one year period after date of shipment provided the equipment has been used according to the instruction manual and have not been abused or tampered with The company will not be responsible for any damage resulting from leakage of water or chemicals caused by improper installation operator carelessness or defective loose plumbing fittings associated with installation and operation of the equipment The company assumes no responsibility for damage in transit and the customer should present any claim for such damage to the carrier This warranty gives you specific legal rights You may also have additional rights that vary from state to state Any unit to be repaired under warranty must be shipped freight prepaid or delivered to a facility authorized to render services provided hereunder Returned unit must be either in its original package or a similar package affording an equal degree of protection All units must have a Material Return Authorization code MRA visible on the returned item MRA s can be obtained by calling 58
10. alarm if any tank falls below this level Following is a table of the automatic switches and what they do TABLE I Item Function 1 Fixer Concentrate Tank Liguid Level Switch Turns ON the alarm and turns OFF both fixer pumps when open 2 Developer Concen Tank Liguid Level Switch Turns ON the alarm and turns OFF both developer pumps when open 3 Water Tank Liquid Level Switch Turns ON the alarm and turns OFF all pumps when open 4 Bottom of Fixer Tank Liquid Level Switch Turns ON the alarm and turns OFF the fixer recirculation pump when open 5 Bottom of Developer Tank Liquid Level Switch Turns ON the alarm and turns OFF the developer recirculation pump when open 6 Top of Fixer Tank Liquid Level Switch Turns ON both fixer pumps when closed 7 Top of Developer Tank Liquid Level Switch Turns ON both developer pumps when closed In addition the PLC has a timing function that cycles the recirculation pumps ON for two minutes and OFF for five minutes except when the low level alarm is ON Control Panel Functions See Figure 1 1 Power Switch This switch controls all electrical power to the RAM C The ON position provides electricity to the PLC level switches and pump motors The green light above the switch glows when there is power to the unit 2 Developer Bulk Add Switch This is a momentary switch which activates the developer metering pump to mix additional developer and pump it into the front holding tank
11. amaged cord or if the appliance has been dropped or damaged until it has been examined by a qualified service technician 4 Do not let power cord hang over edge of table or counter or touch hot surfaces 5 An extension cord should not be used with this unit The unit should be plugged directly into a power outlet 6 To protect against electrical shock hazard do not immerse this appliance in water or other liquids 7 To avoid electrical shock hazard do not disassemble this appliance Call a qualified service technician when service or repair work is required Incorrect reassembly can cause electric shock hazard when the appliance is switched ON SAVE THESE INSTRUCTIONS DESCRIPTION General Comments The RAM C is a fully automatic high volume chemical mixer It is constructed of welded steel and has a fine corrosion resistant baked epoxy finish The RAM C mixes and maintains six gallon tanks of both developer and fixer from containers of concentrated chemistry This is accomplished through the use of high precision bellows metering pumps These tanks are then used to supply up to six processors with fresh chemistry This unit also provides timer controlled recirculation pumps that keep the chemistry well mixed Each tank on the unit is monitored with a pair of float switches The switches keep the tanks full and also shut off the recirculation pump if the tanks ever run low SPECIFICATIONS General Comments Electrical 115 VAC