Home

Tuthill Pump Manual - 30, 40, 80 GPH - Part No. ASL

image

Contents

1. ASL 83930 ASL Technologies LLC ASL 83940 10525 W US Hwy 30 Bldg 3D Wanatah IN 46390 ASL 83980 Phone 219 733 2777 or Toll Free 888 333 2990 Pump amp Motor Facsimile 219 733 2779 or e mail custsvc aslfilter com Www aslfilter com ASL Technologies LLC Quality Policy ASL Technologies LLC was founded with the commitment to be the industry leader in product quality customer service and customer satisfaction in the market places we serve Our patented product line of Electrostatic Fluid Filtration equipment is designed built tested and delivered with these goals in mind The ASL 83940 40 GPH Tuthill Pump and Motor combination replaces the Viking SG0518 GOV 40 GPH pump and motor assembly The ASL 83980 80 GPH Tuthill Pump and Motor combination replaces the Viking SG0535 GOV 80 GPH pump and motor assembly The Tuthill Pump and motor combination was chosen to replace the Viking product due to its maintainability reliability performance and cost Additionally all needed service parts are available from ASL to support the Tuthill Pump and Motor combination without having to replace the entire assembly The Tuthill pump and motor combination was production line incorporated by ASL in the spring of 2001 Your spare replacement Pump motor will have a grey Baldor motor Wiring and part number information for the motor is contained in this manual When initially installing replacing a Viking pump and motor with a Tuthill the ma
2. With the wiring and hoses disconnected remove the four 4 20 nuts and washers and remove the pump motor assembly from the cabinet With both the old and new pumps motors on the workbench transfer the inlet outlet hose fittings to the new pump motor Take care to align the fittings the same way they were Use a suitable thread sealer on all pipe threads Install the pump motor into the cabinet by reversing the above instructions A drop of lubricant on the push lock fittings will ease installation of the hoses Secure all wiring and hoses and proceed to PUMP ADJUSTMENTS on page 5 Replacement of PUMP only If you have determined that only the pump needs to be replaced the motor and it s electrical connections can remain attached to the cabinet l Remove the pump inlet and outlet hoses The fittings are of the push lock type and the hoses must be cut Slit the inlet and outlet hoses the minimum amount necessary to allow removal of the hoses from the push lock fittings Trim the hose ends square for re installation Excessive slitting and or trimming will render the hoses too short and they will have to be replaced There is enough excess hose length to remove and replace the pump at least once or twice Remove the three 4 20 bolts and lock washers securing the pump to the motor Separate the pump from the motor by pulling straight up on the pump body while rotating the pump There is a three piece coupler connecting the pu
3. The ASL Pump is a Mod A shaft e Use tapered plastic sleeve available from Tuthill as part number 1LPF 531 7010 e Lubricate the sleeve e Place seal assembly on the sleeve The tapered end of the sleeve fits into the spring end of the seal assembly e Place the slotted end of the sleeve on a bench Press down on the carbon face of the seal with your fingers and slide the seal to about the midpoint on the sleeve e Place the slotted end of the sleeve over the tang on the pump shaft Line up the outside diameters of the sleeve and shaft by eye e Push seal down with your fingers so that it passes from the sleeve to a position approximately halfway down the shaft e Press the stationary face into the housing plug The lapped surface must be up Protect this lapped surface by covering it with a piece of paper when pressing down on the face Use your fingers for this operation e Place a new O ring on the OD of the housing plug if required and lubricate e Lubricate the carbon face liberally e Re assemble the housing plug into position over the pump shaft Do not nick the seal face by hitting the pump shaft Tighten the housing plug with the spanner wrench The seal will automatically be positioned by this operation e If the pump is equipped with a ball bearing modification K press the bearing onto the shaft Do not hammer into position or press on the bearing outer race e Check pump for free rotation by turning the shaft
4. 733 2777 or Toll Free 888 333 2990 Pumv amp Motor Facsimile 219 733 2779 or e mail custsvc aslfilter com www aslfilter com is recommended that the top port be the suction port This will prevent gravity induced drainage of fluid through the suction port When pipe lines are installed an inverted U bend should be incorporated into the suction line close to the pump for priming purposes The multiple port arrangement in the 5LE offers flexibility but is limited to some common sense restrictions There is an inlet and an outlet side to the pump There must always be at least one pipe on each side Units ordered with the side port option modification S are shipped with port plugs in the top ports To adapt to a 90 porting arrangement the plugs must be relocated Because of its size the 5LE will not mount onto a NEMA 48 frame motor unless the motor is shimmed approximately 1 2 With the ports facing up and viewing the pump from the shaft end the inlet port is on the right for clockwise rotation and on the left for counter clockwise rotation Pumps with built in relief valves are directional Therefore rotation must be specified at time of order The adjusting screw of the internal relief valve must always be located on the suction side of the pump Pumps should be filled with oil at installation and should never be allowed to run dry Every pump installation should have a good foundation Its structure should be sufficiently strong
5. 83930 ASL Technologies LLC ASL 83940 10525 W US Hwy 30 Bldg 3D Wanatah IN 46390 ASL 83980 Phone 219 733 2777 or Toll Free 888 333 2990 Paina amp Motor Facsimile 219 733 2779 or e mail custsvc aslfilter com www aslfilter com e Models 30LA through 1LA and models 30LE through 1LE have a snap ring on the shaft to back up the seal assembly Do not remove this snap ring unless you are completely disassembling the pump Models 2LA 2LE and 5LE do not have a snap ring A step on the shaft is used as the seal backup e Remove the stationary seal face from the housing plug by pressing out from the opposite side e If damaged remove the O ring from the OD of the housing plug Disassembly of Pump The seal assembly must be removed before the pump can be disassembled e Remove the snap ring from the shaft on all models except 2LA 2LE and 5LE e Mark the cover and housing of the pump for proper re assembly e Remove cover screws cover idler and rotor from the housing Check the pump housing rotor idler gear idler pin and cover for wear and chipped or broken teeth The housing bore and rotor OD may be checked for wear by positioning the rotor in the housing and checking for clearance in the bearing The shaft must turn freely without any detectable side play Any side play will require replacement of the housing and or rotor If either of these two parts must be replaced it is economically advisable to replace the entire pump Assemb
6. Instructions for the Tuthill L Series pumps The model used in the ASL FPRS S40 Cabinet is OOLEV 040 CC A S 30 and S 8 units use 30 LEV CC A 9821 Eighty 80 GPH units use the OLEV 040 CC A pumps The manual is reprinted with permission from the Tuthill Pump Group ASL 83930 ASL Technologies LLC ASL 83940 10525 W US Hwy 30 Bldg 3D Wanatah IN 46390 ASL 83980 Phone 219 733 2777 or Toll Free 888 333 2990 Pume amp Motor Facsimile 219 733 2779 or e mail custsvc aslfilter com Www aslfilter com Pat TUTHILL zeae dsc Pump Group sae a baraenn reacties email tuthillpump tuthillcom www tuthill com On Installation and Service Instructions L Series Pumps The 80 GPH pump is 0 LEV 040 CC A 7 The 40 GPH pump is 00 LEV 040 CC A 7 The 30 GPH pump is 30LEV CC A 9821 ASL 83930 ASL Technologies LLC ASL 83940 10525 W US Hwy 30 Bldg 3D Wanatah IN 46390 ASL 83980 Phone 219 733 2777 or Toll Free 888 333 2990 Pump amp Motor Jacsimile 219 733 2779 or e mail custsve aslfilter com www aslfilter com General Description Tuthill s LA and LE Series are compact highly efficient cast iron positive displacement rotary gear pumps with a mechanical seal Built in six sizes they provide nominal capacities from 5 to 14 gallons per minute and pressures up to 500 psi 300 psi in the 5LE They are self priming and particularly suited to handle liquids of 35 to 1000 SSU viscosity Higher viscosities can be handled at reduced speeds The
7. LA Series is supplied with a two bolt flange the LE Series with a three bolt flange Optional mounting feet are available for both Series An internal relief valve is an option with the LE Series Both Series are bi rotational unless outfitted with a relief valve and designed for direct drive at standard motor speeds with modifications available for indirect drive The Pumping Principle Tuthill s LA and LE Series employ the internal gear pumping principle There are only two moving parts Pumping action is based on a rotor idler gear and crescent shaped partition cast integral with the cover Power applied to the rotor is transmitted to the idler gear with which it meshes The space between the outside diameter of the idler and the inside diameter of the rotor is sealed by the crescent As the pump starts the teeth come out of mesh increasing the volume This creates a partial vacuum drawing the liquid into the pump through the suction port The liquid fills the spaces between the teeth of the idler and the rotor and is carried past the crescent partition through the pressure side of the pump When the teeth mesh on the pressure side the liquid is forced from the spaces and out through the discharge port ASL 83930 ASL Technologies LLC ASL 83940 10525 W US Hwy 30 Bldg 3D Wanatah IN 46390 ASL 83980 Phone 219 733 2777 or Toll Free 888 333 2990 Pann amp Motor Facsimile 219 733 2779 or e mail custsve aslfilter com w
8. These can be detected by submerging the pressure line from the discharge side of the pump into a pail of liquid where the air will be seen in the form of bubbles e Direction of shaft rotation is incorrect e Pump shaft is not rotating The coupling is defective or the tongue and groove are not engaged e The relief valve setting is too low Liquid is discharging through the by pass port On ASL Filtration Systems the by pass should be set so the pump enters full bypass at 40 psi maximum Capacity is too low e There are air leaks in the suction line e Suction losses are too high The suction lift is too great or the suction line too small or too long This can be detected by installing a vacuum gauge directly at the pump suction The maximum vacuum at the pump suction should never exceed 15 of mercury Vaporization caused by higher vacuums will generally result in capacity drop off Suction conditions must be redesigned Pump speed is too slow The strainer is too small or obstructed The suction port or pipe is not immersed deeply enough in the liquid Piping is improperly installed permitting an air pocket to form in the pump e Increased clearances or wear in the pump will sometimes cause the pump to deliver an insufficient supply of fluid This can generally be corrected by reducing the thickness of the cover gaskets A folded gasket or a slight amount of dirt can exaggerate the problem and cause leakage 16 ASL 8393
9. new pump the by pass pressure may not be correctly adjusted Care should be taken to avoid gross over pressurization of the system This procedure may on some models also require that the cover safety switch be defeated Maintenance personnel are cautioned to take extra care when operating the system with the covers removed Refer to the pump vendor service manual starting on page 7 of this manual 1 Start system and wait until output flow is observed 2 Remove the acorn nut on the pump relief valve 3 Insert a screwdriver into the slot of the adjusting screw and hold it steady 4 Loosen the locking nut with a wrench by turning counterclockwise S Slowly close the throttling ball valve until the system pressure reaches 40 psi If the pressure fails to reach this level with the throttling valve closed turn the adjusting screw inward clockwise until the desired pressure is reached Adjusting clockwise raises the pressure setting 6 If the pressure reaches 40 psi before the throttling valve is completely closed turn the adjusting screw outward counterclockwise until 40 psi is reached Adjusting counterclockwise lowers the pressure setting 7 Once the by pass is set at 40 psi with the throttling valve closed open the throttling valve for a few minutes to let the system flow Operation with the pump in full bypass for long periods will cause excessive heat buildup and could cause damage to the pump 8 Slowly close the t
10. safeguard against flooding Care must be taken to properly support the suction and discharge piping so that no strain is put on the pump due to either weight or expansion Piping strain can result in misalignment hot bearings worn couplings and vibration It is important that the piping used be clean and free of chips or scales Proper Installation Unsatisfactory pump installations are usually characterized by poor suction conditions for the specific liquid being handled Suction conditions should be minimized to prevent vaporization of the liquid If vacuum conditions force the liquid to vaporize cavitation will occur resulting in loss of capacity premature wear and noisy operation When handling high viscosity liquids the speed of the pump must be reduced and the size of the lines increased to prevent cavitation Note Pipe line friction increases at a rapid rate with an increase in viscosity For a given pump and motor larger pipe lines are necessary to maintain the same pump pressure when changing from a thin fluid to a thick one Most Tuthill LA and LE Series pumps are supplied with both ports on the same plane Pumps with this type of porting arrangement should always be installed with both ports pointing upward to insure proper priming If it is necessary to install the pump with the ports pointing to either side it 9 ASL 83930 ASL Technologies LLC ASL 83940 10525 W US Hwy 30 Bldg 3D Wanatah IN 46390 ASL 83980 Phone 219
11. to hold the pump rigid and to absorb any strain or shock that may be encountered The installation should be leveled checked for proper piping alignment and then fastened securely Method of Drive Direct drive through a traditional flexible coupling is recommended However do not expect the flexible coupling to compensate for misalignment Contact the coupling manufacturer to determine the maximum amount of misalignment to which the coupling can be subjected LA and LE Series pumps can be driven in either direction of rotation unless outfitted with an internal relief valve The seal chamber communicates with the neutral zone and therefore the seal is subjected to approximately one half of the discharge pressure All pump and motor units must be properly aligned during assembly and periodically checked since misalignment may occur later due to abuse or other conditions Pipe strain can force the pump and motor shafts out of alignment Therefore all piping to the pump must be properly supported Do not allow the pump to act as a pipe support Provide for proper expansion of pipes when handling hot liquids Allow pump to reach operating temperature slowly Rapid temperature change can result in damage to the cast iron components Recheck the alignment Never align a pump and motor supplied with a pin type coupling without first removing the pins Never depend upon sight or feel Use proper gauges when aligning the pump Never operate the pump
12. with a suitable wench There will be a definite resistance to turning because of the seal load The pump must turn freely without binding 15 ASL 83930 ASL Technologies LLC ASL 83940 10525 W US Hwy 30 Bldg 3D Wanatah IN 46390 ASL 83980 Phone 219 733 2777 or Toll Free 888 333 2990 Pumv amp Motor Facsimile 219 733 2779 or e mail custsvc aslfilter com www aslfilter com Changing Rotation LA and LE Series pumps are bi directional and will work equally well in either direction with no modification However if outfitted with an internal relief valve model LEV these pumps become rotational Rotation cannot be changed in the field unless the housing is replaced Do Not change rotation on an ASL Filtration System Pump To change the location of the suction port on a pump outfitted with Tuthill s unique automatic reversing feature models RLA and RLE e Remove the cover screws e Rotate the cover 180 so that the boss on the cover points to the new suction inlet port e Align the mounting holes and reinstall the cover screws Note Location of the suction port cannot be changed in the field on RLEV pumps unless the housing is replaced Troubleshooting No fluid is delivered e Power is not on e Net positive suction head available NPSHA is lower than required for the inlet conditions and the vapor pressure of the liquid pumped Calculate NPSHA and redesign piping if necessary e Leaks in suction line or port passages
13. without all guards in place 10 ASL 83930 ASL Technologies LLC ASL 83940 10525 W US Hwy 30 Bldg 3D Wanatah IN 46390 ASL 83980 Phone 219 733 2777 or Toll Free 888 333 2990 Pumv amp Motor Facsimile 219 733 2779 or e mail custsvc aslfilter com www aslfilter com Relief Valve Protection The LA and LE Series are positive displacement pumps As the pump rotates liquid is positively delivered to the discharge side of the pump If the discharge line is closed off pressure will increase until the drive stalls and or fails the pump breaks or ruptures or the piping bursts To prevent this from happening the use of a pressure relief valve is required A relief valve that directs the flow back to the supply tank is recommended The internal relief valve available on LE Series pumps is designed for overpressure protection only It is not intended as a flow control device or for any similar use Continuous operation of the relief valve will result in excessive heat buildup within the pump cavity which could cause serious internal damage Make certain the adjusting screw of the relief valve is located on the suction side of the pump Unless otherwise specified at the time of order all LEV pumps are supplied with the standard spring with a range of 55 120 psi 40 70 in the 5LE set to provide full bypass relief at 55 psi Note that the ASL pump contains a special by pass spring which must be set to provide full by pass relief at 40 psi To
14. 0 ASL Technologies LLC ASL 83940 10525 W US Hwy 30 Bldg 3D Wanatah IN 46390 ASL 83980 Phone 219 733 2777 or Toll Free 888 333 2990 Pumv amp Motor Facsimile 219 733 2779 or e mail custsvc aslfilter com www aslfilter com Pump works spasmodically e Leaky suction line e Varying suction conditions e Air or vapor in the fluid Excessive power draw e Pressure too high e Liquid is more viscous than originally expected e Suction or discharge lines obstructed e Insufficient horsepower e Drive shaft and pump misaligned e Pump binding due to insufficient end clearance e Pump shaft is bent e Misalignment within the pump due to bad piping or poor installation causing strain or distortion Pump is noisy Pump is cavitating due to inadequate suction conditions Misalignment of coupling Coupling is set too close to pump Vibration of pump due to worn or bent shaft Air leaks on suction side of pump or air entrainment in the fluid Pump leaks e Cover bolts need tightening or cover gasket is defective e Worn or defective seal Material Returns If it becomes necessary to return a pump to the factory a Return Goods Authorization RGA must be obtained from either your local Authorized Distributor or our Chicago plant No RGA can be issued until a completed Material Safety Data Sheet MSDS has been forwarded to our Chicago plant and return of the pump approved e Tuthill pumps are precision built and must be ha
15. adjust the relief setting within the range of a given spring s capability e Remove the acorn nut Not supplied with model 5LEV e Insert a screwdriver into the slot of the adjusting screw and hold it steady e Loosen the locking nut with a wrench by turning counterclockwise e Throttle the outlet line until the differential pressure at the pump port is at the desired level e Ifthe pressure fails to reach this level with the throttling valve closed turn the adjusting screw inward clockwise until the desired pressure is reached Adjusting clockwise raises the pressure setting e Ifthe pressure reaches the desired level before the throttling valve is completely closed turn the adjusting screw outward counterclockwise until the desired pressure is reached Adjusting counterclockwise lowers the pressure setting e Retighten the nut to lock the setting in place and replace the acorn nut e Recheck the pressure gauge reading If an internal relief valve has not been supplied with the pump some other means of protection must be utilized These include in line safety relief valves pressure shutdown switches or other similar devices Strainer Protection Strainers are used to remove contaminated particles from the fluid system and extend pump life Every pump should be protected from these particles by a strainer in the suction line Strainer size and mesh of screen are determined by the rate of flow and viscosity of the fluid Co
16. bottom out Re install inlet and outlet hoses A drop of lubricant on the push lock fittings will ease installation of the hoses Proceed to PUMP ADJUSTMENTS on page 5 Replacement of MOTOR only If you have determined that only the motor needs to be replaced the pump and its attached hoses can remain in the cabinet l 10 11 12 Start by removing the motor wiring box cover and disconnecting the wire nuts tying the SO cord to the motor leads The green ground wire is secured with a green screw to the motor inside the motor wiring box Pull the SO cord out of the motor wiring box and plastic Heyco connector Note that wire connections and color codes are located on the motor nameplate as well as page 6 of this manual Remove the three 14 20 bolts and lock washers securing the pump to the motor Separate the pump from the motor by pulling straight up on the pump body while rotating the pump There is a three piece coupler connecting the pump to the motor During pump motor separation one or more of these coupler pieces may come out with the pump Carefully inspect the three piece coupler for signs of wear or damage The coupler should be replaced if found defective Note that a new coupler is included with a replacement motor or pump and motor combination but not with a replacement pump With the pump and motor separated and the wiring removed remove the four 14 20 nuts and flat washers securing the motor to the cabin
17. et studs and lift the motor out of the cabinet Transfer the black Heyco wiring fitting and locknut to the wiring box of the new motor Install the plastic female tang coupler and the metal center section coupler pieces on the new motor shaft Install the male tang coupler piece on the pump Install the new motor onto the cabinet studs and secure with four 4 20 locknuts and flat washers Using a twisting motion install the pump onto the motor taking care to align the splines of the couplers Once aligned the pump will drop into position Re install the three 4 20 bolts and lock washers thru the pump to the motor Note that these bolts are 4 long Longer bolts will bottom out Re install the SO cord through the Heyco fitting and re connect wiring in accordance with the diagram on page 41 of this manual Tie up any loose wiring and return the unit to service Note that pump adjustments should not be required when replacing the motor only ASL 83930 ASL Technologies LLC ASL 83940 10525 W US Hwy 30 Bldg 3D Wanatah IN 46390 ASL 83980 Phone 219 733 2777 or Toll Free 888 333 2990 Pump amp Motor Facsimile 219 733 2779 or e mail custsve aslfilter com Www aslfilter com PUMP ADJUSTMENTS The following procedure should be followed after replacement of the pump Note that these adjustments are CRITICAL to proper system operation and should be read and understood before continuing WARNING When first installing a
18. hould be installed as close as possible to the pump Rotate pump shaft to ensure it turns freely without binding Recheck alignment and ensure all guards are in place Make sure piping is independently supported and no strain is being transmitted to the pump Make sure the safety relief valve is installed correctly Check pump rotation Open suction and discharge gate valves Check for any leaks once gate valves are open After completing these checks the pump can be started CAUTION The pump should not be run dry If after approximately 60 seconds there is no discharge of liquid stop the pump and investigate the possible cause Failure to comply with this could cause severe damage to internal seals bushings and or metal parts Pump Performance Data Size Capacity gpm 3 30L Note 30LEV CC A 9821 1725rpm 5 gpm OOL 8 Note 0OOLEV 040 CC A 1725rpm 666 gpm OL 1 6 Note OLEV 040 CC A 1725rpm 1 333 gpm 1L 2 7 2L 4 9 Based on pumping a fluid of 200 SSU 5L 12 9 viscosity at 100 psi and 1750 rpm 12 ASL 83930 ASL Technologies LLC ASL 83940 10525 W US Hwy 30 Bldg 3D Wanatah IN 46390 ASL 83980 Phone 219 733 2777 or Toll Free 888 333 2990 Panne Motor Facsimile 219 733 2779 or e mail custsve aslfilter com www aslfilter com WARNING Failure to follow these instructions could result in serious bodily injury or death Do not attempt to work on any Tuthill pump installation before completing the steps below Di
19. hrottling valve fully Observe that the system pressure stays at 40 psi with the throttling valve fully closed Re adjust if necessary 9 Once all adjustments are complete open the throttling valve completely and tighten the nut to lock the setting in place Replace the acorn nut on the pump by pass valve and tighten ASL FPRS UNIT TYPICAL FLUID FLOW DIAGRAM OUTLET Cust supplied I O hoses Grey Hose Hydraulic Oil Reservoir Electrostatic Cell Water INLET Absorber Siea Sample Port Blue Hose Drain ASL 83930 ASL Technologies LLC ASL 83940 10525 W US Hwy 30 Bldg 3D Wanatah IN 46390 ASL 83980 Phone 219 733 2777 or Toll Free 888 333 2990 Pump amp Motor Facsimile 219 733 2779 or e mail custsvc aslfilter com Www aslfilter com Motor Service Data Nameplate Data P N 88514 GREY BALDOR MOTOR Model 34G510 5506 P N 88514 Volts 115 208 230 Hz 60 KVA Code L H P 4 FR 48 YZ Phase 1 RPM 1725 sf 1 35 ENC TEFC TEFC 40 C FLA 5 0 2 6 2 5 end ae SFA 5 6 3 2 8 Time Cont Baidor Motots Rate Duty NEMA Eff 55 Eff NEMA Eff 55 57 Motor Wiring Data Grey Baldor Motor Only Motor is ASL Factory wired Lo Volt CW Rotation 2 White 5 Lo Volt Factory Wired this wa 5 8 3 1 Black 1 L1 3 tivo 08230 Volt ONLY 8 so O 4 L2 Do not reverse rotation The following pages contain the Installation and Service
20. intenance man will have to drill additional mounting holes as the Tuthill is a NEMA 48YZ Frame motor while the Viking was a NEMA 56 Frame Baldor Motor Tuthill Pump Outlet Port gt Inlet Port Relief Valve ASL 83930 ASL Technologies LLC ASL 83940 10525 W US Hwy 30 Bldg 3D Wanatah IN 46390 ASL 83980 Phone 219 733 2777 or Toll Free 888 333 2990 Pump amp Motor Facsimile 219 733 2779 or e mail custsve aslfilter ccom Www aslfilter com ASL 83930 40 80 Spare Replacement Parts DESCRIPTION PART NUMBER Call ASL for any parts not listed Motor only 50 60 Hz with coupler Three piece pump to motor coupler only Pump Replacement Parts pee O O ring viton Seal Assembly viton Other parts not listed Removal Replacement Adjustment PUMP MOTOR ASSEMBLY The pump and motor assembly used in your FPRS is designed for continuous duty and will give many years of trouble free service For your convenience the pump manufacturers service manual is located in the last section of this manual starting on page 7 The pump and motor consists of three basic parts which are all easily field replaceable The pump itself is attached to the motor housing with 3 1 4 20 x 34 long bolts and lock washers Coupling the pump to the motor is a three piece tang coupler which consists of two hard plastic splines and a center metal adapter Note that the pump shaft has the male tang and the motor shaf
21. ly of Pump The following must be carefully followed when the pump is re assembled e Clean all parts thoroughly using great care to eliminate all dirt e Install the rotor in the pump housing e Apply the gasket to the cover Use a new gasket if the old one is damaged Models 30LA 30LE and 5LE are also supplied with an O ring in the cover Replace if damaged e Place the idler gear on the pin in the cover assembly e Place the cover assembly with gear on the pump aligning the matching marks for proper location e Install the cover screws Tighten gradually alternating from a screw on one side to a screw on the opposite side e Install the snap ring on the shaft except models 2LA 2LE and 5LE 14 ASL 83930 ASL Technologies LLC ASL 83940 10525 W US Hwy 30 Bldg 3D Wanatah IN 46390 ASL 83980 Phone 219 733 2777 or Toll Free 888 333 2990 Pann amp Motor Facsimile 219 733 2779 or e mail custsve aslfilter com www aslfilter com Assembly of Seal e Clean all parts thoroughly using great care to eliminate all dirt e Oil the shaft with a suitable lubricating oil If the pump has an EPR seal apply a silicon based lubricant instead e Apply the appropriate lubricant to the inside of the new seal assembly For standard full length shafts with flat and or keyway e Place seal assembly on the pump shaft e Push seal down with your fingers to a position approximately half way down the shaft For modification A tang shafts
22. mp to the motor During pump motor separation one or more of these coupler pieces may come out with the pump Carefully inspect the three piece coupler for signs of wear or damage The coupler should be replaced if found defective Note that a new coupler is included with a replacement motor and a pump and motor combination but not with a replacement pump Before ordering a replacement pump determine if the coupler will need to be replaced so it can be ordered at the same time It is a good idea to replace the coupler when replacing either the pump or the motor With the old and new pumps on the workbench transfer the inlet and outlet fittings to the new pump Take care to align the fittings as they were Use a suitable thread sealer on all pipe threads ASL 83930 ASL Technologies LLC ASL 83940 10525 W US Hwy 30 Bldg 3D Wanatah IN 46390 ASL 83980 Phone 219 733 2777 or Toll Free 888 333 2990 Pump amp Motor 10 Facsimile 219 733 2779 or e mail custsve aslfilter com Www aslfilter com Install the plastic female tang coupler and the metal center section coupler pieces on the motor shaft Install the male tang coupler piece on the new pump Using a twisting motion install the pump onto the motor taking care to align the splines of the couplers Once aligned the pump will drop into position Re install the three 4 20 bolts and lock washers thru the pump to the motor Note that these bolts are 34 long Longer bolts will
23. ndled with care e Pumps must be drained of all fluid and the ports plugged to prevent foreign material from getting into the pump e Pumps must be packaged securely to prevent damage while in transit Contact ASL Technologies for return of Defective pumps installed in ASL Filtration Systems END OF SERVICE MANUAL 17
24. nsult the strainer manufacturer for recommendations 11 ASL 83930 ASL Technologies LLC ASL 83940 10525 W US Hwy 30 Bldg 3D Wanatah IN 46390 ASL 83980 Phone 219 733 2777 or Toll Free 888 333 2990 Pann amp Motor Facsimile 219 733 2779 or e mail custsvc aslfilter com www aslfilter com Never use a strainer with a built in automatic by pass on the suction line set to open under 30 Hg vacuum Install the strainer according to the designated direction of flow locating it so that it is accessible for servicing Use a duplex type strainer when shutdown during service is not possible Provide a vacuum gauge in the suction line for determining when the strainer requires cleaning Make certain strainer baskets are properly reinforced so as not to collapse under 30 Hg vacuum WARNING All Tuthill pumps contain residual 200 SSU lube oil from the factory production test Determine if this is compatible with the fluid you are pumping If the fluid is incompatible consult the factory If the pump is to operate at elevated temperatures it should be brought up to operating temperature gradually Rapid or sudden introduction of liquid at an elevated temperature into the cold liquid chamber of the pump could cause damage to the seal or other internal parts Do not run the pump dry This could cause severe damage to the seal bushings and or metal parts Prior to starting the pump double check the following Pressure and vacuum gauges s
25. sconnect the drive so that it cannot be started while work is being performed Review the Material Safety Data Sheet MSDS applicable to the liquid being pumped to determine its characteristics and the precautions necessary to ensure safe handling Vent all pressure within the pump through the suction or discharge lines All Tuthill pumps contain residual 200 SSU lube oil from the factory production test Determine if this is compatible with the fluid you are pumping If the fluid is incompatible consult the factory HOUSING IDLER IDLER PIN COVER ROTOR COVER BOLTS COVER GASKET HOUSING BUSHING RETAINING RING HOUSING PLUG O RING SEAL ASSEMBLY Disassembly of Seal The seal assembly in LA and LE Series pumps can be changed without disassembly of the rest of the pump e Place the pump in a vise with the shaft facing up so that one jaw grips across the two ports Do not tighten excessively as the pump housing may be distorted e Inspect the shaft at the keyway flat or tang Any burrs will interfere with removal of the housing plug and bearing assembly e Remove the housing plug with a spanner wrench available from Tuthill as p n OL 506 e Remove the seal from the shaft The rubber boot will be bonded to the shaft so it is necessary to push down on the seal to break this bond Grasp the metal outer shell with any suitable device and pull the seal assembly upward Remove the spring and washer 13 ASL
26. t is the female end Replacement of the pump or coupler is straightforward and should present no problem for maintenance See the following section for removal and replacement of the pump along with required adjustments ASL 83930 ASL Technologies LLC ASL 83940 10525 W US Hwy 30 Bldg 3D Wanatah IN 46390 ASL 83980 Phone 219 733 2777 or Toll Free 888 333 2990 Pump amp Motor Facsimile 219 733 2779 or e mail custsve aslfilter com Www aslfilter com Pump Motor COMBINATION Replacement of the pump and motor is straightforward The pump motor is secured with studs or bolts For ease of access the Electrostatic Cell should be removed l 2 6 All Pump Motor assemblies are pre wired at the factory for the correct rotation and voltage with a 36 length of S O cord Depending on ASL unit model strip prepare and wire the bare end of the SO cord into your unit as needed Note that wire connections and color codes are located on the motor nameplate as well as page 6 of this manual The hose connections to the motor are of the push lock type and will have to be cut Slit the inlet and outlet hoses the minimum amount necessary to allow removal of the hoses from the push lock fittings Trim the hose ends square for re installation Excessive slitting and or trimming will render the hoses too short and they will have to be replaced There should be enough excess hose length to remove and replace the pump at least once or twice
27. ww aslfilter com JN WARNING Failure to follow these instructions could result in serious bodily injury or death These pumps should not be used for handling plain water corrosive or abrasive liquids or liquids not possessing adequate lubricity Do not attempt to work on any Tuthill pump installation before completing the steps below Disconnect the drive so that it cannot be started while work is being performed Review the Material Safety Data Sheet MSDS applicable to the liquid being pumped to determine its characteristics and the precautions necessary to ensure safe handling Vent all pressure within the pump through the suction or discharge lines All Tuthill pumps contain residual 200 SSU lube oil from the factory production test Determine if this is compatible with the fluid you are pumping If the fluid is incompatible consult the factory Location LA and LE Series pumps are designed for working pressures up to 500 psi 300 psi in the SLE and are required to develop 25 mercury vacuum at 0 psi on factory test While these pumps will develop as high as 27 of vacuum it is a sound engineering practice to avoid extreme vacuum whenever possible Select a pipe size to reduce line friction loss to a minimum The pump should be located as close to the source of supply as conditions permit and if possible below the level of the liquid in the reservoir When necessary to locate the pump in a pit provisions should be made to