Home
The OP300 unit service manual
Contents
1. 132 6 3 2 How to reconfigure Database connection ODBC 133 6 4 Renaming Database Compulter ssssssssssssseeeemeennnnenn 134 6 4 1 Configuring the file server sc ier p opere p Reon aaa td aver 134 6 4 2 Modifying Datasource ini eseeesesssseenn 134 6 4 3 Modifying Already Installed Clients to Use New Database Computer 135 Upgrading the software ooo nitent tedio anette 137 7 1 Upgrade from CLINIVIEW 7 1 0 or newer sseeeeemm nen nnnnnnnee 137 7 2 Upgrade from CLINIVIEW 7 0 2 or older 141 Adding features FE es ET IEE 143 8 1 Adding devices hoe ee a on addat SNE UE 143 8 2 Enabling SmartNav in the software ssssssssee 144 8 9 Adding options det 145 9 10 11 12 8 3 1 Adding options using Advanced modify eessesssssssss 145 8 3 2 Adding options using Add ons ssssee 147 S roca esl TTD pase 149 9 1 Uninstalling the SO WaFe usie rr o eee ente oett eset 149 CLEINIVIEW Manager ccs deste ptt eles a tt all 151 TO o e a 151 10 2 ATCTIVIPIO ecce ek ee Reece eta ie aut cte Oct rod Do cL eL uL AE ENS 152 10 2 1 Create archive sient ia eee epi ates ane n EDEN MdX CEN aui ned vn agus tuu i a e IRE RR 152 10 2 2 Restore archive Satin Seth ge inl aula et ecole tel lee 153 10 35 MAGGS mc Saris tthe fan behest ade dads steel te nat tec 154
2. 6 2 To the maximum extent permitted by applicable law in no event shall Licensor or its suppliers be liable for any actual or special incidental indirect or conse quential damages whatsoever including but not limit ed to damages for loss of profits or confidential or other information for business interruption for personal inju ry for loss of privacy for failure to meet any duty includ ing of good faith or of reasonable care for negligence and for any other pecuniary or other loss whatsoever arising out of or in any way related to the use of or ina bility to use the Software the provision of or failure to provide support services or otherwise under or in con nection with any provision of this Software License even in the event of the fault tort including negli gence strict liability breach of contract or breach of warranty of Licensor or any of its suppliers and even if Licensor or any of its suppliers has been advised of the possibility of such damages Instrumentarium Dental 209804 rev 2 209804 rev 2 12 Software license Applicable Law and Jurisdiction 7 1 This Software License to be construed governed by and interpreted in accordance with the laws of Finland excluding the UN Convention on Contracts for the Inter national Sale of Goods 7 2 Disputes arising from or in connection with this Soft ware License are to be settled by arbitration by one ar bitrator The Board of Arbitration of the Central
3. Modifying the Datasouce ini is essential to new clients that are installed after renaming the database computer Datasource ini is located at the folder CVDATA ClientConfiguration File should contain the following lines Data Source hostname OLD_COMPUTER_NAME CliniView OLD_COMPUTER_NAME should be replaced with the new computer name Instrumentarium Dental 209804 rev 2 209804 rev 2 6 Software database 6 4 3 Modifying Already Installed Clients to Use New Database Computer Name Note This step must be done in every client computer To modify already installed clients to use new database computer open Control Panel and select Administrative Tools In the Administrative Tools open Data Sources ODBC and go to System DSN page Now select a system data source named CLINIVIEW and click Configure Microsoft SQL Server DSN Configuration This wizard will help you create an ODBC data source that you can use to connect to SQL Server What name do you want to use to refer to the data source Name CLINIVIEW How do you want to describe the data source Description Which SOL Server do you want to connect to Replace the OLD COMPUTER NAME with the new one and click finish Instrumentarium Dental 135 6 Software database 136 Instrumentarium Dental 209804 rev 2 7 Upgrading the software Note Check CLINIVIEW system requirements before starting upgrade and also requirements for any devices that w
4. Patients to be archived Patient data or images have not been edited for last 1 zi month s Search Lastname Firstname Number Size MB Lastname Firstname Number Size MB Osbourne Judy 7 0 50 Select gt Smith James 5 3 34 Patient Sample 5 0 02 Esa lt Remove Select All gt lt Remove All Total size 0 5 MB Total size 3 3MB IV Remove images from image folder after archiving Start Close 2 Select media type for archiving Select the temporary archival folder 3 Define the time for inactive patients For example if you select inactive patients or data within the past six months the program offers all images of those patients to be archived 4 Select the patients whose images you want to archive Also select if you want those images to be removed from the patients image folder on the hard disk Other wise the archived images are shown as archived imag es in the patients image folder 5 To start the archiving click Start 6 Archive operation creates archive folders CV_xxx in the temporary archival folder To burn archived images to DVD ROM use DVD disk software and burn CV_xxx folders to DVD Note Store CLINIVIEW installation and archive DVD s very carefully Instrumentarium Dental 209804 rev 2 209804 rev 2 10 CLINIVIEW Manager 10 2 2 Restore archive 1 To restore the archive select Restore from CLINI VIEW Manager dialog To restore an archive from another
5. ________ User management IP or computer name WIN D93BC86MA58 Restore Database backup f s Save Close I licence location logs Exi Report Trash INSTRUMENTARIUM 2 3 3 Existing Database Installation EDBI The patient database can be installed to an existing Microsoft SQL Server database engine instead of using Microsoft SQL Server Express engine which is provided with the software installation package Database engine feature If more advanced configuration options are needed please see the ADBI installation pdf located in the Tools Database ADB Install folder on the software DVD Note EDBI is not supported in 64 bit MS SQL Server Use ADBI Advanced Database Installation if you need to install the patient database in 64 bit MS SQL Server MS SQL Server instance configuration for patient database 1 Database installation requires a Named instance that describes its use MS SQL Server s default instance name is unnamed or empty which is not supported by the software Instrumentarium Dental 35 2 Software installation 36 2 SQL Server Authentication mode must be set to Mixed mode the software uses SQL Server authentication when accessing the database This setting can be changed during installation or using MS SQL Server Management studio How to configure mixed mode authentication using MS SQL Server Management studio Start SQL Server Manage
6. lt Back Next gt Cancel Local license server address can be configured also from workstation License Manager tool To configure local license server address using License Manager click Settings button and enter the local license server address 72 Instrumentarium Dental 209804 rev 2 3 Licensing CLINIVIEW 3 2 2 License Manager The License Manager tool lists all licenses active in the computer and allows the licenses to be managed To access the Licence Manager select Start gt CLINIVIEW Tools gt CLINIVIEW Manager gt Licence or select CLINIVIEW software Tools License Manager immense TE P INSTRUMENTARIUM Acquire license Activate license 4 Activated licenses Product Version License type Status Activation key Publisher Activation ENABLED Refresh T Return P Qt Settings C Show log ii 209804 rev 2 Instrumentarium Dental 73 3 Licensing CLINIVIEW 74 Activate license button Starts the license activation process see chapter 3 2 1 Online connection and 3 2 2 Offline connection Return license button CLINIVIEW license can be active only in one computer at a time Any license which has been activated through the INSTRUMENTARIUM DENTAL license server can be returned to the INSTRUMENTARIUM DENTAL license server This is needed when you need to transfer the license to a different computer for example if the
7. Request file creation succeeded Created request file as C Users John Desktop CLINIVIEW_120619084902 xml Show in folder Process response Note If you are unable to wait for the response from Instrumentarium Dental press Finish to close the win dow Instrumentarium Dental 209804 rev 2 3 Licensing CLINIVIEW You can continue the activation process later by click ing Process response in the Offline activation re quest window Offline activation First generate activation request file and then process the received response file Generate request Process response If you are unable to complete the offline activation pro cess in the time available you can activate the CLINI VIEW 30 day trial period so that CLINIVIEW can be used temporarily 11 The Select response window appears Select the activation request response file from the folder where it was saved Offline activation Import the received response file to complete the activation process Select the activation request response file C temp SCANORA_120130090013 lic Back Next Cancel Click Next A message appears confirming that CLINIVIEW is now licensed 209804 rev 2 Instrumentarium Dental 69 3 Licensing CLINIVIEW 70 3 2 0 1 Trial period activation 1 In the license activation request window click the Start trial now button CLINIVIEW License Activation 00000 LX J INSTRUMEN
8. 10 3 1 Remove archived ottenuto ebd a ee ah eerie eles 154 TOS ALA SC uuo LR 155 10 3 1 2 Image folder location cocos 156 10 3 1 3 Report Exposure statistics cccccccccecccceesseeeeeeeeeeeeeeeeeeeees 156 10 4 Database io ee ee ae dea tete Mae ec E LC cA 159 10 4 1 User Matiagertierit ro oer ioo eeepc onse eoo ao Br deese habeto RE 159 10 4 1 1 Database backup sd ap ecu poe capo pendet a Eat na RE enne 160 10 4 1 2 Trash aoi iioii re boerne do Satoh a awstats M alot essai S ot RS ec eg 161 TOME 1 3 Syste M LOIS cut eut aa saco Tons cant epe oer eet Ere Ev ee Eo oH pica eaters 162 10 4 1 4 Search l99S acu ret ot Sent tete c te toe eate 163 10 5 File Server Configuration eoo ie e teet Uo veka di ee ei De ite 164 10 0 LICOTI Se ac ote cete eut rp pte eed a ut eui pul peu ete tU ctetuer 164 Using practice management interface cece eee eeeeeeeeeeeeeeeneeeeeeeeeeeeeeeeeeeeeees 165 DW EM Isirseitieilo me ce D ER 165 11 2 How to use CLINIVIEW ini suser nennen nnne 168 11 3 Interface to access image information sssseeseee 169 Software license i ested oe he ciiin iex 171 1 Introduction 1 Introduction 209804 rev 2 1 1 General CLINIVIEW hereafter called the software is a complete solution for digital image acquisition processing viewing and storing The software supports INSTRUMENTARIUM DENTAL Sigma Sigma M and Snapshot intr
9. 6 Software database 6 1 3 Changing updated Standalone database to Network database Note This instruction is valid only for a database upgraded from a software version older than CLINIVIEW 10 2 2 Databases installed with CLINIVIEW 10 2 2 or later can be used as standalone or network database without any modifications needed Client and database are installed on modality workstation and the database is not shared i e database has been installed without the Database sharing feature The standalone database is modified so that it is shared to network and clients installed on other computers are able to connect to it 1 Goto Control Panel gt Add or Remove Programs Programs and Features in Vista 2 Select CliniView and click Change Wait for the soft ware Setup Maintenance program screen to load Select Advanced Modify and click Next Select Database sharing feature under Database title and click Next 5 If license key is asked enter your license and click Next and Next 6 When restart is suggested select Yes want to restart my computer now and click Finish 7 Log on to Windows using an account with administrator rights to finish maintenance 8 Now the database is shared to network and other client computers can be configured to use it See chapter 6 Changing database location by modifying ODBC alias BR Database backup and restore Database backup and restore utilities are installed under
10. Digital Intra oral X Ray Image Storage For Processing Digital Intra oral X Ray Image Storage For Presentation Photographic images VL Photographic Image Storage default Secondary Capture Image Storage Multi frame Grayscale Byte Secondary Capture Image Storage Mutti frame Grayscale Word Secondary Capture Image Storage Multi frame Truecolor Secondary Capture Image Storage CB3D Enhanced CT Image Storage default CT Image Storage CB3D scout Digital X Ray Image For Processing DX default Digital X Ray Image For Processing DX Computed Radiography Image Storage 94 Instrumentarium Dental 209804 rev 2 209804 rev 2 5 3 5 Configuring DICOM Single VT Projection images Digital X Ray Image For Processing DX default Digital X Ray Image For Processing DX Computed Radiography Image Storage Single VT Reconstruction images Digital X Ray Image For Processing DX default Digital X Ray Image For Processing DX CB3D Image Storage Computed Radiography Image Storage Worklist configuration DICOM settings xl General SOP Classes i t Storage Print Query Retiieve Storage sc r Worklist SCP Application Entity Title DICOM AE IP address or host name 127 0 0 1 Port number 104 Polling interval sec 60 Refresh timeout sec 30 Search method Refresh from worklist SCP Verify Items retrieved Days be
11. To use a device install also the sensor specific gain file 000000 1838000062 sdf xml Note Only for OP100 D OC100 D OP200 D OC200 D Sigma and Sigma M To use an X ray device install also the sensor specific gain file by using Gain Installer Start gt Programs gt CLINI VIEW gt Tools gt Gainlnstaller 209804 rev 2 Instrumentarium Dental 143 8 Adding features 144 8 2 Note Snapshot gain files are installed automatically when the Snapshot image capture is performed for the first time Insert the Gain file media and browse the Gain file Select all the gain files and click Install Remember to copy the gain files for each sensor If the gain files need to be updated click Update to copy the files to local workstations Enabling SmartNav in the software Start the software and select Tools Installed devices IntraCam Sigma OP100D 0C100D Cancel OP200D Oc200D OP200DSmartNav DC200DSmartNav Sigma M small Sigma M large Snapshot sensor Express OP300 Panoramic OP300 Cephalometric OP300 3D Enable SmartNav by selecting OP200DSmartNav OC200DSmartNav from the list The OPD OCD image capturing button appears in the software image capturing tool bar and file menu Instrumentarium Dental 209804 rev 2 8 Adding features 8 3 Adding options 8 3 1 Adding options using Advanced modify You can add a new option DICOM at any time after the installation 1
12. sioe t cota catch eaten aod dg ree e kde Rae TRE Sdn 2 UE EE eiui e CR 3 UNES CC mE c 4 1 4 1 Minimum system requirements for the software client 4 1 4 2 Minimum system requirements for the software database 6 1 4 3 Minimum system requirements for RECO Server ssssssss 8 1 5 The software Specifications 5 1 eoe ieekuoare saneta nre ka nae nahe ean aa rara ad aa Para ea 9 1 6 The software compatibility table eee eec eieceieeeee eee eterni 12 2 SoltwareinstallatlOn csi rie sinc anas et cece URN AMAA Lam as EE SEI DEAE 13 2 1 Standalone p Pr a 18 22 Small PUM oi det St east ae eat tne Ao 21 2 2 1 Small network server unie hc ht elentue Cote rete ueteri ends 21 2 2 2 Small network viewing workstation sssseeeeeeeenee 25 2 3 Network Systemi oce steterit eet herent vas acces kay tees baee eS 30 2 3 1 Network database e ee keke dei eee he elie 30 2 3 2 Simple Database installation ccccceeeeeeeeeeeeeeeeeeeeeeseeeeeeeeeeeeeeeees 30 2 3 8 Existing Database Installation EDBI eeeseesss 35 2 3 4 Network modality workstation cceeeeeeeeeeeeeeeeeeeeeeeneeeeeeeeeseeeeees 43 2 3 5 Network modality workstation with DICOM eese 47 2 3 6 Stand
13. 3 1 2 840 10008 5 1 4 1 1 7 4 1 2 840 10008 1 20 1 1 2 840 10008 5 1 4 1 2 1 1 1 2 840 10008 5 1 4 1 2 1 2 1 2 840 10008 5 1 4 1 2 2 1 1 2 840 10008 5 1 4 1 2 2 2 Wi Mi QoQo Qo Qo Qo Qo 00 A o LA o e o 0 a 00000 E 209804 rev2 6 Software database 6 Software database 209804 rev 2 6 1 Changing the software database location Note If content of local database needs to be moved see chapter 6 3 Restoring database to a new installation and or location 6 1 1 Changing database location by uninstalling local database using Modify This procedure removes the database from the local computer where the software client is installed If you do not want to remove the local database see chapter 6 Changing database location by modifying ODBC alias 1 Goto Control Panel gt Add or Remove Programs Pro grams and Features in Vista 2 Select CliniView and click Change Wait for the soft ware Setup Maintenance program screen to load Select Modify and click Next Unselect Database feature and click Next A question If database is uninstalled all patient data is going to be deleted from the database tables Are you sure you want to continue is shown Click Yes 6 Select or enter the database server where remote the software database resides e g enter the value under key hostname from server s DataSource ini and click Next default location of DataSource ini in the server is C CVData
14. 46 Generated by CliniView Manager 1 2 2 4 PaloDEx Group Oy 3 My Computer The report contains the following data Header Exposure statistics Report date e g CLINIVIEW 2006 01 30 Total count of images by modality Date Range mage list with values Image Date Modality Pa tient name Exposure values and DAP value The image list is sorted by modality and image date Note Only images that are captured with the software ver sion 7 1 or later are shown Export Data The easiest way to export data is to use the clipboard as following Select Edit gt Select All Ctrl A from Internet Ex plorer Select Edit gt Copy Ctrl C Open third party software e g Word or Excel Select Edit gt Paste Ctrl V 209804 rev 2 Instrumentarium Dental 157 10 CLINIVIEW Manager Make your own report It is also possible to make your own style sheet but XML skills are required Choose Style Sheet for a report A Click Settings on Image Report dialog Browse or enter Style Sheet path and click Save CLINIVIEW Manager remembers the last used style sheet P Image Report Settings Report Style sheet C Program Files CliniView T ools M anager StyleS heet default_eng xs 158 Instrumentarium Dental 209804 rev 2 10 CLINIVIEW Manager 10 4 Database 10 4 1 User Management User management makes it possible to define categories for different users and define passw
15. After the reboot log in with administrator privileges to finish the installation IV Launch CLINIVIEW after finishing Installshield lt Back Finish 13 After the computer restarts start the License Manager and activate network licenses See Chapter 3 2 1 1 Li censing CLINIVIEW network for more information 209804 rev 2 Instrumentarium Dental 41 2 Software installation 14 Optional If the local network does not support DNS or WINS you must change File Server to use the server s IP address in place of its host name To do this open CLINIVIEW Manager Click File Server Config and enter the user name and password when prompted Enter the IP address of the server and click Save Close CLINIVIEW Manager File Help CLINIVIEVV Manager Archive Images Database File Server Configuration Create povanperrane NOES User management Restore Database backup Trash licence Location logs Eit Report INSTRUMENTARIUM 42 Instrumentarium Dental 209804 rev 2 2 Software installation 2 3 4 Network modality workstation 1 Insert software DVD into DVD ROM drive 2 If the InstallShield Wizard does not appear after a few moments browse to the software DVD and double click CLINIVIEWSetup exe to begin installation Note If the User Account Control window appears you must allow changes to continue installation 3 Select CLINIVIEW Network Client Select Features Sel
16. DICOM 5 10 The software DICOM SOP Classes SOP Class Name Verification Verification Service Class DICOMDIR Basic Directory Storage SCU Digital X ray Image Storage for Presentation Digital X ray Image Storage for Processing Digital Intra oral X ray Image Storage for Presentation Digital Intra oral X ray Image Storage for Processing VL Photographic Image Storage CT Image Storage Enhanced CT Image Storage Computed Radiography Image Storage Secondary Capture Image Storage Multi frame Grayscale Byte Secondary Capture Image Storage Multi frame Grayscale Word Secondary Capture Image Storage Multi frame True Color Secondary Capture Image Storage Storage Commitment SCP Storage Commitment Push Model Query Retrieve SCU Patient Root Find Patient Root Move Study Root Find Study Root Move Modality worklist SCU Modality Worklist DICOM Print SCU Printer SOP Class Basic Grayscale Print Management Basic Film Session Basic Film Box Basic Grayscale Image Box Basic Color Print Management Basic Color Image Box 126 Instrumentarium Dental SOP Class UID 1 2 840 10008 1 1 1 2 840 10008 1 3 10 1 2 840 10008 5 1 4 1 1 1 1 1 2 840 10008 5 1 4 1 1 1 1 1 1 2 840 10008 5 1 4 1 1 1 3 1 2 840 10008 5 1 4 1 1 1 3 1 1 2 840 10008 5 1 4 1 1 77 1 4 1 2 840 10008 5 1 4 1 1 2 1 2 840 10008 5 1 4 1 1 2 1 1 2 840 10008 5 1 4 1 1 1 1 2 840 10008 5 1 4 1 1 7 1 2 840 10008 5 1 4 1 1 7 2 1 2 840 10008 5 1 4 1 1 7
17. Delete xl Are you sure you want to delete selected object To confirm removal click Yes 10 4 1 3 System Logs To view user actions in the software select Logs from CLINIVIEW Manager dialog x Search Object use x Logs in the last fi days Seach Action Logon User WorkStation Action Object Description 2004 03 24 09 00 26 admin FIDC98X0J Logon 2004 03 24 09 18 54 admin FIDCS amp XQJ Logon 2004 03 24 09 22 05 admin FIDC98x0J Logon Instrumentarium Dental 209804 rev 2 209804 rev 2 10 CLINIVIEW Manager 10 4 1 4 Search logs It is possible to restrict search results with the following filters Object Action and number of last days Select Object where action is targeted as All Database Image Patient Study or User Select Action The following combinations are possible Object All All Actions Database Update Image Archive Capture Delete Hide Import and Re store Patient Delete and Hide Study Delete and Hide User Login and Logoff Define the number of days you want to look back for the software system logs If 1 is selected then today s logs are shown and if 2 is selected then today s and yesterday s logs are shown and so on To start searching logs click Search The search list can show 500 items at a time If more items exist it is necessary to restrict search with filters or by removing log items Instrumentarium De
18. No will restart my computer later Remove any disks from their drives and then click Finish to complete setup After the reboot log in with administrator privileges to finish the installation IV Launch CLINIVIEW after finishing Installshield 50 Instrumentarium Dental 209804 rev 2 209804 rev 2 2 Software installation 11 Select software default language Note Software language can be changed at any time within the software from the Tools menu Languages Y Language selection im Select language English Lx OK 12 Activate software license with DICOM feature See chapter 3 2 Licensing CLINIVIEW software stan dalone 13 The installed devices window will be displayed Select the devices to be connected to this workstation and click OK to enable the devices INTRACAM OK SIGMA OP100D 0C100D Cancel OC200D OP200DSmartNav OC200DS martNav SIGMA M small SIGMA M large SNAPSHOT sensor OP30 OP300 Panoramic OP300 Cephalometric OP300 3D z EN 14 If the selected device requires a gain file the software will prompt to open the GainInstaller tool Browse to the location of the gain file s and install them using the GainInstaller tool Note Only certain devices require a gain file 15 Software is ready for use A patient named Calibration Patient will be created and opened This patient can be used to store all calibration images for the install
19. PATIENT Add m C Find Response VR Caption 0010 0020 0010 0010 0008 0054 String Patient ID String Patient name String Retrieve AE Title cme The Advanced window shows default patient search criteria normally these can be left empty Instrumentarium Dental 209804 rev 2 209804 rev 2 5 Configuring DICOM 5 6 1 Query options Editing default Query Retrieve messages Module patient Root v level PATIENT Patient Root Study Root Patient Study Onl From the module and level scroll boxes choose different types of query levels In these boxes the following information can be found Module Level Patient Root Patient Study Series Image Study Root Study Series Image Add Edit and Remove buttons Click Add to increase the items in one of the lists request or response The following dialog appears which allows relevant information to be entered into the fields xl Taq VR String E Value Remember that a Tag is usually written as an ordered pair of two byte numbers The first two bytes are sometimes called a group number with the last two bytes being called an element number e g 0010 0010 or 0038 001C Instrumentarium Dental 117 5 Configuring DICOM 118 The VR or Value Representation can be thought of as the type specifier for the values that can
20. Review the installation settings and click Next to start installation process Start Copying Files Review settings before copying files Setup is ready to install CLINIVIEW to this computer with the following settings Current Settings Features selected Client Installed devices Destination folder C Program FilesXCLINIVIE W 2 INSTRUMENTARIUM Installshield 209804 rev 2 Instrumentarium Dental 27 2 Software installation 28 7 Wait until installation is completed and click Finish to view the software release info Readme and start the software InstallShield Wizard Complete Setup has finished installing CLINIVIEW 10 2 2 on your computer View Readme Ep instrumentarium Cancel 8 Select software default language Click OK to continue Note Software language can be changed at any time within the software from the Tools menu Languages n j Language selection Select language English 9 To activate the license select Use Network license See Chapter 3 3 2 Configuring workstations to use CLINIVIEW software network license 10 The installed devices window will be displayed If this workstation is only used for viewing images you do not need to select any devices just click OK to continue Note If you want to use this viewing station also for image capturing select the devices to be connected to this workstation Instrumentarium Dental 209804 rev 2 209804
21. Start Control Panel Programs and Features 2 Select CLINIVIEW Click Change CJ Control Panel All Control Panel Items gt Programs and Features E Search Programs and F Control Panel Home Uninstall or change a program View installed updates To uninstall a program select it from the list and then click Uninstall Change or Repair Tum Windows features on or zu Organize Uninstall Change Name E Publisher Installed On Size Version dB cunmvew 10 22 __Instrumentarium Dental 225 013 668 MB 10224 am PaloDEx Group 2 25 2013 495MB 4134226 3BJINSTRUMENTARIUM DENTAL License Server Instrumentarium Dental 2 25 2013 490MB 100 3506 MATLAB Component Runtime The MathWorks 2 25 2013 262MB 74 E amp Microsoft SQL Server 2008 R2 Microsoft Corporation 2 25 2013 5 Microsoft SQL Server 2008 R2 Native Client Microsoft Corporation 2 25 2013 609MB 10 5125000 Ij Microsoft SQL Server 2008 R2 Setup English Microsoft Corporation 2 25 2013 324MB 10 512500 0 d Microsoft SQL Server 2008 Setup Support Files Microsoft Corporation 2 25 2013 216MB 10127310 Ij Microsoft SQL Server Browser Microsoft Corporation 2 25 2013 900MB 105125000 Ij Microsoft SQL Server VSS Writer Microsoft Corporation 2 25 2013 360MB 10 51 25000 E Microsoft Visual C 2008 Redistributable x64 9 0 3 Microsoft Corporation 2 25 2013 252KB 900720 E Microsoft Visual C 2008 Redistributable x64 9 0 3 Microsoft Corporation 7 31 2012 788KB 9 0 30729 4148 E Mi
22. empty 20100130 Max Density Basic Film Box Replace if empty 300 20100140 Trim Basic Film Box Replace if empty zi zl Edit Delete Cancel Enp Edit button Select the attribute in the list which is needed to be changed the line turns blue Click Edit Tag 20100110 Name Empty Image Density Module Basic Film Bx 0 Type REE lm Default value mak 000 00 ro cne Check the correct default values from the printer documentation or hospital administrator Enter new information and click OK The changes appear in the Print Attributes list 114 Instrumentarium Dental 209804 rev 2 209804 rev 2 5 6 5 Configuring DICOM Delete button Delete an attribute from the print attributes list 1 Select the attribute to be deleted 2 Click Delete 3 Adelete confirmation message appears 4 Click Yes to delete the print attribute Query Retrieve configuration The Query Retrieve service provides a tool for search and retrieve of patients and images from image archives Query Retrieve page brcom settings xi General SOP Classes Worklist Storage Print Query Retrieve Storage scp r Query Retrieve SCP Application Entity Title Pacs IP address or host name 127 0 0 1 Port number 104 Application Entity Title for Move Service Application Entity Title Workstation r Query Model Model Patient root E QR Scheduler m 1 Failed retrieve
23. install Please select the feature that you want to install CLINIVIEW Quick Install Standalone or small network server No Volumetric Tomography or DICOM features Soe CLINIVIEW Network Client fte Ley Client without database No Volumetric Tomography or DICOM features pom utm B INSTRUMENTARIL CLINIVIEW Advanced INSTRUPENTABIOM l Xt Standalone or small network server d Includes Volumetric Tomography and DICOM features CLINIVIEW Manuals i Instrumentarium Dental 209804 rev 2 209804 rev 2 2 Software installation 4 Select Install CLINIVIEW database this option installs database engine and CLINIVIEW database Select database option Database options Description Install CLINIVIEW software patient and x ray image database Search existing MS SQL Servers C CLINIVIEW software only 2 INSTRUMENTARIUM Installshield lt Back Next gt 5 Choose Destination folder for the database engine Click Next to accept default and continue or click Browse to change the location Note The destination folder for the database engine contains only the database files not images Image data location will be selected in the next step Choose Destination Location Select folder where setup will install files Please enter the path for database engine instance This folder is where the database tables are saved C Program Files
24. new destination in the upper list and the attributes in the lower list This indicates that you have successfully added a new destination to the storage application Repeat the above steps each time to add a new destination Instrumentarium Dental 209804 rev 2 209804 rev 2 5 Configuring DICOM Storage page Delete button Allows a destination to be deleted from the destination list To do this 1 Select the destination to be deleted the line is high lighted 2 Click Delete 3 Adelete confirmation message appears Click Yes to delete the destination Storage page Edit button Allows the destination information in the storage desti nation list to be changed To do this 4 Select the destination to be edited the line is highlight ed 5 Click Edit 6 The Edit Destination window appears T Edit the destination information Edit Destination Fa Destination AE Title STORAGE SCP IP address 10 0 0 2 Port 104 EN 8 Click OK to accept the changes The destination infor mation in the storage window is updated Storage page Advanced button The Log Files and Performance pages provide parameters for adjusting the low level settings of the DICOM network services There are similar settings for all the DICOM network services See chapter 5 8 Log File and Performance Settings Instrumentarium Dental 103 5 Configuring DICOM 104 In addition to the settings common
25. path than the default click Restore from Restore archives x Archived Volumes Volume Label Cv 0004 CD ROM 650 ECV 0004 CV CD ROM 650 EAC 0001 Cv 0002 CD ROM 650 E Cv_0002 Cv 0003 CD ROM 650 ECV 0003 Restore Restore fom Close 2 Select the archive to be restored and click Restore Confirm Object Restore xi 4re you sure you want to restore selected object 3 Click Yes xi Please Insert the CD ROM disc labeled Cv 0002 7 Cancel 4 After clicking Restore from browse the directory for archives 5 Select a folder and click Yes Instrumentarium Dental 153 10 CLINIVIEW Manager 10 3 Images 10 3 1 Remove archived Note Removing archived images can be done automati cally after archiving by checking the Remove images from image folder after archiving box on the Create Image Ar chives dialog Previously archived images can be removed from the server to free up more storage space Select the removal criteria between 0 to 12 months of time during which the patient s images have not been reviewed To remove the archived images from the patient image folder select Remove achieved from CLINIVIEW Manager dialog 1 Select the appropriate time and click Start xi Remove images if Patient data or images have not been edited for last E 3 x month s Start Close 2 Click Yes to start removing the archived images xi Are you s
26. retry count 2 d Retry interval minutes 30 FT Advanced Complete the fields as follow AE Title Obtain from the hospital administrator for example QR SCP IP address Obtain from the hospital administrator for example 10 0 0 2 Port The TCP port on which the remote DICOM system listens for connections The default DICOM port number is 104 Obtain from the hospital administrator Instrumentarium Dental 115 5 Configuring DICOM 116 Verify button See the Verify button in the previous chapters of this manual for more information Application Entity Title for Move Service Specify the AE Title of the target Application Entity i e the AE where the retrieved images are sent Typically this is the local Storage SCP AE Query Model Select either Patient Root or Study Root Failed Retrieve Retry Count This is the limit for the retry attempts that would made after retrieving is failed 0 means that not retries are done if the initial retrieve attempt Retry interval This is the time interval in minutes that will be waited between the retries The Advanced Button See or make any changes to the patient image search click Advanced The Advanced window appears Advanced ELLAS Query Options Log Files Performance l Model Level Patient m r C Find Request Tag VR Value 0010 0020 0010 0010 0008 0052 String String String
27. the password for user click Set Password f Set password for admin x Old Password New password Four character minimum Confirm new password Fill in the fields and click OK Instrumentarium Dental 209804 rev 2 10 CLINIVIEW Manager 10 4 1 1 Database backup Choose the schedule for automated backup of the Database tables Note This function does not create a backup of the imag es See Chapter 6 3 Database backup and restore Ff Database Backup Timing j xl gt Schedule backup Confirm Change X Are you sure you want to change backup timing Click Yes 10 4 1 2 Trash Various objects that have been previously marked as deleted in the software can be permanently deleted from the database in the trash menu This means that the software user can not permanently delete any information unless the administrator empties the deleted information from the trash Select Trash from the from CLINIVIEW Manager dialog xl Objects to be deleted Trash Date 2l Select All Restore Delete Close 209804 rev 2 Instrumentarium Dental 161 10 CLINIVIEW Manager 162 Select all All objects can be selected for deletion Restore Deleted information can be restored for further usage Confirm Object Restore xl re you sure you want to restore selected object Confirm restore Delete Information is deleted permanently Confirm Object
28. window re mains temporary after clicking OK To save the changes permanently click OK or Apply in the DICOM Worklist con figuration tab Instrumentarium Dental 209804 rev 2 209804 rev 2 5 Configuring DICOM Colors button Click Colors and the Set Colors window appears To change a status color click the appropriate arrow button beside each color A Color selection window appears xl Status Color New Taken Stored E Cancel Select a basic or custom color for the required status and click OK Note All the changes made in the Color window remains temporary after clicking OK To save the changes perma nently click OK or Apply in the DICOM Worklist configura tion tab Advanced button The Log Files and Performance pages provide parameters for adjusting the low level settings of the DICOM network services There are similar settings for all the DICOM network services See chapter 5 8 Log File and Performance Settings 5 3 6 Other options Hide following worklist items Choose the option that suits best Option Effect None Items are not hidden Older than current date All items older than current date are hidden Stored All items that are stored and older than current date older than current date are hidden Instrumentarium Dental 99 5 Configuring DICOM 100 Copy Scheduled Procedure Step Description to Study Description If this option is selected then Sch
29. x86 CLINIVIEWAD atabase V 27 INSTRUMENTARIUM Installshield Instrumentarium Dental 31 2 Software installation 6 Choose the destination for image data Click Next to continue or click Browse to change the location Choose Destination Location Select folder where setup will install files Please enter the path for database media files This folder is where the patient images are saved INSTRUMENTARIUM Installshield 7 Select Yes I want to install License Server Click Next to continue Select License Server License Server Description This is License Server installation License Server is installed to a server No I do not want to install License Server e INSTRUMENTARIUM Installshield 32 Instrumentarium Dental 209804 rev 2 209804 rev 2 2 Software installation 8 Select No I do not want to install CLINIVIEW soft ware Click Next to continue Select Workstation Software option Workstation Software options Description C Yes I want to install CLINIVIEW software CLINIVIEW software is not installed isteuventarim Installshield 9 Review the license agreement and click Yes to accept the license terms and continue with the installation License agreements Do you accept the following license agreements Microsoft SQL Server Express license View license Gp instrumentarium Installshield Instru
30. 2 Instrumentarium Dental 101 5 Configuring DICOM 102 5 4 1 Storage page Destinations Storage page Add new button Verify Set as Defaul estination erge IP Address AE Title Merge sl tor e scp Advanced Add new Edit Delete Allows a new destination for the images to be added Click Add new and the Add New Destination window appears Fill in the fields as follows 1 Destination Section describing a remote DICOM appli cation Client refers to the destination by a DICOM Ap plication Entity Title AE Title and this is the same way it is referred to in the application profile A destination name can be for example DICOMArchive AE Title The AE Title is a string of 16 characters or less with no spaces for example STORAGE SCP Note The AE Title string is case sensitive IP Address a remote host name or its IP address for example 10 0 0 2 Port a TCP port which the remote DICOM system lis tens to The default DICOM port number is 104 Obtain from the hospital administrator If Storage Commitment feature is used define the Storage Commitment SCP settings either choose the Use the same destination for Storage Commitment option or define the Storage Commitment SCP AE Ti tle IP address and TCP port explicitly Note Port num ber must not be greater than 65535 When defined the storage destination click OK The storage page appears with the
31. 4 rev 2 2 Software installation 6 Review installation settings and click Next to start in stallation process Start Copying Files Review settings before copying files Setup is ready to install CLINIVIEW to this computer with the following settings Current Settings Features selected Client Installed devices Destination folder C Program Files CLINIVIEW INSTRUMENTARIUM Installshield 7 Wait until installation is completed and click Finish to view the software release info Read me and start the software InstallShield Wizard Complete Setup has finished installing CLINIVIEW 10 2 2 on your computer View Readme Gp instrumentariu Installshield 209804 rev 2 Instrumentarium Dental 45 2 Software installation 46 8 Select software default language Note Software language can be changed at any time within the software from the Tools menu Languages F j Language selection 10 Select language English OK To activate the software license select Use Network license See Chapter 3 3 2 Configuring workstations to use CLINIVIEW software network license The installed devices window will be displayed Select the devices to be connected to this workstation and click OK to enable the devices OP100D 0C100D Cancel OP200DSmartNav OC200DSmartNav SIGMA M small SIGMA M large SNAPSHOT sensor EXPRESS P l J OP300 Panora
32. 925336 before the software installation Processor 2 GHz Pentium 4 or better Memory RAM At least 1 GB 32 bit OS or 2 GB 64 bit OS Note Ifthe audio card is installed speakers are needed to hear the signal Note In the case of installation in Windows Server 2003 Windows Server 2003 hotfix KB925336 must be installed first before installation can be started Pentium is a registered trademark of Intel Corp Windows is a registered trademark of Microsoft Corp Other product and company names mentioned herein may be trademarks and if so registered and or unregistered trademarks of their respective owners For safe and reliable system performance you need to arrange an appropriate backup procedure meaning that you regularly back up the system and store the labelled back up media in a safe place The end user is solely responsible for backing up all data Instrumentarium Dental 209804 rev 2 1 Introduction 1 5 The software specifications APPLICATION SOFTWARE PRODUCT NAME CLINIVIEW Image acquisition modalities OP100 D OC100 D OP200 D OC200 D OP30 OP300 Express Volumetric Tomography Sigma Snapshot Sigma M KaVo Pan eXam Pan eXam Plus Scan eXam TWAIN compatible scanners and digital cameras m Video acquisition devices VfW format WDM format Patient database Microsoft SQL Server 2008 R2 SP1 Express Workgroup Standard Enterprise Editions
33. CLINIVIEW Quick Install Standalone or small network server No Volumetric Tomography or DICOM features CLINIVIEW Network Client Client without database EW Advanced INSTRUMENTARIUM lone or small network server Includes Yolumetric Tomography and DICOM features CLINIVIEW Manuals Installshield Volumetric Tomography or DICOM features 4 Review the license agreements and click Yes to accept the license terms and continue with the installation License agreements Do you accept the following license agreements CLINIVIEW software license View license Microsoft Direct runtime license View license Microsoft SQL Server Express license View license 2 INSTRUMENTARIUM Installshield 18 Instrumentarium Dental 209804 rev 2 2 Software installation 5 Review the installation settings and click Next to start installation process Start Copying Files Review settings before copying files Setup is ready to install CLINIVIEW to this computer with the following settings Current Settings Features selected Database Licensing Server Installed devices Destination folder instrumentarium C Program Files x86 CLINIVIEW Database media folder CACVDATAN Database tables folder C Program Files 85 NCLINIVIEWA D atabase Installshield Note License Server will always be installed when using Quick installation 6 Wait until installation is completed and click Fi
34. Chamber of Commerce of Finland shall appoint the ar bitrator and the Rules of the said Board are to be fol lowed in the arbitration proceedings The arbitration shall be held in Helsinki Finland and conducted in the English language 7 3 Notwithstanding the foregoing Licensor and its suppliers shall have the right but not the obligation to undertake legal proceedings in a court of your domicile principal place of business or other appropriate court to i settle any issue or dispute arising out of or relating to monies due by you to Licensor ii protect or enforce any patent trademark copyright or other intellectual property right confidential information or trade secrets or ili proceed with litigation commenced by a third par ty 7 4 Judgment upon the award rendered may be en tered in any Court having jurisdiction or application may be made to such Court for a juridical acceptance of the award and an order of enforcement as the case may be General 8 1 This Software License together with license terms of third party suppliers of Licensor if any constitute the entire agreement with respect to the subject matter hereof between you and the Licensor and supersedes all previous oral or written communications or agree ments relating to the same Only a written instrument expressly agreed to by the parties hereto may modify this Software License 8 2 The failure of Licensor to enforce any provision of this Software Li
35. Client 7 Wait while Microsoft SQL Server 2008 database engine is being uninstalled 8 When restart is suggested select Yes want to restart my computer now and click Finish 9 Logon to Windows using an account with administrator rights to finish maintenance OR Instrumentarium Dental 127 6 Software database 128 6 1 2 Changing database location by modifying ODBC alias Client computer is configured to use other than local database and the local database is kept installed although the software client is no longer using it 1 2 3 4 7 Go to Control Panel Administrative Tools Data Sources ODBC Select System DSN tab Select CliniView and click Configure Modify the Server field to correspond with the new da tabase location Change local CliniView to SERVER CliniView or you can use the drop down menu which shows all avail able SQL Servers When the new SQL Server is written in the Server field click Next Select With SQL Server authentication using a login ID and password entered by the user Also check Con nect to SQL Server to obtain default settings for the ad ditional configuration options and fill in a valid Login ID Password admin admin by default Click Next Click Next Finish and OK After both cases 6 1 1 and 6 1 2 client computer is configured to use the external software database Instrumentarium Dental 209804 rev 2 209804 rev 2 6 2
36. Dental 209804 rev 2 209804 rev 2 1 Introduction WLAN WLAN for Sigma M CB3D additional requirements See the device manuals Other software Anti virus software is recom mended to protect the system from viruses Other device Device to support archive media VT additional requirements At least 2 GB RAM Display adapter supporting the following B OpenGL 2 0 or higher B Texture3D OpenGL extension W 128 MB video RAM dedicated not shared Instrumentarium Dental 1 Introduction 1 4 2 Minimum system requirements for the software database and SQL Server Operating system OS Windows XP Professional SP3 32 bit Windows Vista Business Ultimate Enterprise SP2 32 or 64 bit Windows 7 Professional Ultimate Enterprise SP1 32 or 64 bit Windows 8 Pro Enterprise 32 or 64 bit Windows Server 2003 SP2 32 bit Windows Server 2008 SP2 32 bit Windows Server 2008 R2 SP1 Windows Server 2008 SP2 64 bit Windows Server 2012 64 bit requires Windows Server 2003 hotfix KB925336 before the software installation Supported SQL Server versions Memory RAM Processor SQL Server 2005 SP2 32 bit x86 edition Express Standard Workgroup Enterprise SQL Server 2008 with SP1 32 bit x86 edition Express Standard Workgroup SQL Server 2008 R2 32 bit x86 edition Express Standard Workgroup SQL Server 2012 32 bit x86 edition Express S
37. ENGLISH CLINIVIEW 10 2 2 Installation Manual 209804 rev 2 209805 A5 Copyright Manufacturer CLINIVIEW 10 2 2 Code 209804 rev 2 Date April 25 2013 Copyright 4 25 13 by Instrumentarium Dental PaloDEx Group Oy All rights reserved INSTRUMENTARIUM DENTAL CLINIVIEW are common law trademarks of Instrumentarium Dental PaloDEx Group Oy ORTHOPANTOMOGRAPH ORTHOCEPH are registered trademarks of Instrumentarium Dental PaloDEx Group Oy Documentation trademark and the software are copyrighted with all rights reserved Under the copyright laws the documentation may not be copied photocopied reproduced translated or reduced to any electronic medium or machine readable form in whole or part without the prior written permission of Instrumentarium Dental The original language of this manual is English Instrumentarium Dental reserves the right to make changes in specification and features shown herein or discontinue the product described at any time without notice or obligation Contact your Instrumentarium Dental representative for the most current information CE 0537 Instrumentarium Dental PaloDEx Group Oy Nahkelantie 160 P O Box 20 Fl 04300 Tuusula FINLAND Tel 358 10 270 2000 Fax 358 10 270 2230 For service contact your local distributor CLINIVIEW 10 2 2 Table of Contents Miei Iur e re M 1 CI General EPIIT EDITI 1 1 2 Manufacturer s Ilabilitys
38. IEW Add ons Add DICOM features Volumetric Tomography features or License Server CLINIVIEW Advanced Modify Add or remove features CLINIVIEW Repair INSTRUMENTARIUM i fous 2 INSTRUMENTARIUI Reinstall all previously installed features CLINIVIEW Remove e e Remove all installed features CLINIVIEW Manuals Installshield Instrumentarium Dental 147 8 Adding features 4 See already installed add ons features in the Add ons dialog Add features by selecting the needed features e g DICOM Click Next r CUNIMIEW 10 2 2 InstallShield Wizard Add on installation Select Add on features F Lic Iv DICOM i i sisse V Ul i Installshield lt Back Nest 5 Select DICOM components Select features Select DICOM additional features IT DICOM Modality Worklist M DICOM Print IV DICOM Storage INSTRUMENTARIUM Installshield lt Back Nest 6 InstallShield Wizard may ask 7 System is successfully modified a restart is recom mended 148 Instrumentarium Dental 209804 rev 2 9 Uninstalling 209804 rev 2 9 1 Uninstalling the software To uninstall the software select Start gt Control Panel gt Programs and Features select CLINIVIEW and click Remove Follow the instructions on the screen Or To uninstall the software insert software DVD The software installation prog
39. INSTRUMENTARIUM Installshield 5 In the Database Server Login window click Browse to search for MS SQL Server instance on this workstation Select the local instance from the list and click OK Enter the MS SQL Server administrator sa password Please contact the local administrator if you do not know the sa password Click Next to continue Database Server Login Select database server and authentication method Browse Database Server rx From the list of servers below select the database server you like to target instrumentarium Installshield 38 Instrumentarium Dental 209804 rev 2 2 Software installation 6 Choose the destination for image data click Next to continue or click Browse to change the location Choose Destination Location Select folder where setup will install files Please enter the path for database media files This folder is where the patient images are saved e INSTRUMENTARIUM Installshield ack o Next gt 7 Select Yes or No depending if the License Server is to be installed in this computer Select License Server License Server Description This is License Server installation License Server is installed to a server No I do not want to install License Server INSTRUMENTARIUM Installshield lt Back Next gt Cancel Note One License Server must be installed to pro vi
40. Image storage Local or network Password security Yes Imaging procedures pan ceph See Volumetric Tomography User Manual User program Chapter in OP100 D OP200 D OP300 and OP30 User Manual Imaging procedures intraoral Series Mount exposure an optional feature Single exposure Imaging procedures 3D See OP300 User Manual Instrumentarium Dental 1 Introduction Image processing Brightness amp Contrast Zoom Move Noise Reduction Edge enhancement Embossment Invert Mirror Rotate Sharpen Unsharp mask Pseudocolor Isodensity color Optimize contrast low medium high Gamma correction adjustments Equalized histogram logarithmic histogram linear histogram Note CB3D 3D images re quire 3rd party viewing and or planning software Overlay graphics Text Line Free hand Angle Rectangle Circle Arrow Region of Interest tools Implant tools Drag or Erase graphics Edit graphics Save graphics Note CB3D 3D images re quire 3rd party viewing and or planning software Measurements Length Calibration Angle Free Angle Note CB3D images require 3rd party viewing and or plan ning software Image Printing MS Windows compatible printers DICOM Printers CLINIVIEW DICOM Multi image printing Free print layout design Image information printing Image archiving CLINIVIEW manager application Ins
41. Language selection Select language English z OK 17 To activate the license select Activate Workstation li cense See Chapter 3 2 Licensing CLINIVIEW soft ware standalone 18 The installed devices window will be displayed Select the devices to be connected to this workstation and click OK to enable the devices OP100D oci00D Cancel P200DSmartNav OC200DSmartNav SIGMA M small SIGMA M large SNAPSHOT sensor EXPRESS OP30 OP300 Panoramic OP300 Cephalometric OP300 3D Y 19 If the selected device requires a gain file the software will prompt to open the GainInstaller tool Browse to the location of the gain file s and install them using the GainInstaller tool Note Only certain devices require a gain file 20 Software is ready for use A patient named Calibration Patient will be created and opened This patient can be used to store all calibration images for the installed de vice s 21 Test installation by acquiring an image according to de vice user manual or quick guide 22 Configure the desired user settings for the software See User manual General Settings chapter for details 23 Configure the DICOM settings and test their functional ity See chapter 5 Configuring DICOM for details Instrumentarium Dental 59 2 Software installation 60 Instrumentarium Dental 209804 rev 2 3 Licensing CLINIVIEW 209804 rev 2 3 1 Important licensing in
42. M printers Print Attributes Tag List To the Print Tag List add settings for every DICOM printer e g media size 110 Instrumentarium Dental 209804 rev 2 209804 rev 2 5 Configuring DICOM 5 5 1 Print page Destinations AE Title IP Address Port Number Set LUT Advanced Add new Edit Delete Print page Add new button Add a new DICOM printer by clicking Add new Edit Printer Properties X Printer Name AE Title mms IP address o003 Port 104 Capabilities IV Basic Grayscale Print Management Basic Color Print Management imei Complete the fields as follow 1 Printer name Application refers to the printer by a DICOM Application Entity Title AE Title and this is the same way it is re ferred to in the application profile In this field enter a name for AE Title for example DICOM PRINTER AE Title Obtain from the hospital administrator for example PRINT SCP IP address Obtain from the hospital administrator for example 10 0 0 3 Port The TCP port on which the remote DICOM system lis tens for connections The default DICOM port number is 104 Obtain from the hospital administrator Instrumentarium Dental 111 5 Configuring DICOM 112 5 Capabilities If the DICOM printer supports grayscale OR color print ing select Basic Grayscale Print Management Basic Color Print Management If the printer supports both printi
43. OMATICALLY 1 USE PRACTICE MANAGEMENTS 1 Instrumentarium Dental 209804 rev 2 209804 rev 2 11 Using practice management interface PATID 00000 PATLNAME 0 PATMNAME 0 PATFNAME 0 PATSOCSEC 0 PATBD 0 PROVIDER1 0 PROVIDER2 0 ADDRESS1 0 ADDRESS2 0 CITY 2 0 STATE 0 ZIP 0 HOMEPHONE 0 WORKPHONE 0 FAX 0 EMAIL1 0 EMAIL2 0 Some PMS software that uses previous versions of the software might require that USE_PRACTICE_MANAGEMENT is permanently set by the user to 1 and that ae ea a DERE It is recommended that the PMS application sets both USE_PRACTISE_MANAGEMENT 1 and CLEAR PRACTISE MANAGEMENT AUTOMATICALLY 1 The CLINIVIEW 7 1 and later can read patient information from any ini file if the following line is added to PracticeManagementInterface section Instrumentarium Dental 167 11 Using practice management interface 168 BRIDGEFILE LOCATION OVERRIDE C my_ini_file ini How to use CLINIVIEW ini Set CLEAR PRACTICE MANAGEMENT AUTOMATICALLY 1 if the PMS software automatically sets USE_PRACTICE_MANAGEMENT 1 Otherwise set the key to 0 To add a patient Set USE PRACTICE MANAGEMENT 1 Set PATID to a patient ID that does not exist in the software database yet A Fill in the patient data fields Rejstart the software To alter patient information Set USE PRACTICE MANAGEMENT 1 Set PATID to match the patient whose information is
44. PaloDEx Group imagng devices Serial Link PCI Davicel lA Ports LOM amp LET Update Driver MR Processors Disable Sound video and game Uninstall i Storage volumes F System devices Scan for hardware changes Universal Serial Bus zon Properties Instrumentarium Dental 83 4 Driver installation 84 4 4 4 5 Settings 3 Click OK 9 II Serial ink PCI driver Warning You are about to uninstall this device from your system Cancel Sigma See Sigma Installation amp User Manual Intraoral camera installation The software supports image capturing with WDM Windows Driver Model and VFW Video For Windows WDM is recommended for the software Install the video capture card and the drivers supplied with your intraoral camera following the intraoral camera s installation instructions To enable intraoral camera capture select IntraCam in Tools Settings Installed devices Clicking Intraoral camera capture opens the intraoral camera window Click Settings to open the settings dialog To hide intraoral camera capture button de select IntraCam in Tools Settings Installed devices To achieve the best possible image quality it is recommended that the camera device is checked Click Settings to open the settings dialog Instrumentarium Dental 209804 rev 2 209804 rev 2 4 Driver installation Settings Video Format and Source prae es eS
45. SCP page allows the storage parameters to be defined The service is used when a remote DICOM application sends the images to the software The software works as Storage Service Class Provider SCP to the remote system Define the software storage service application entity title and TCP port number on the Storage SCP page Note Do not use the same AE Title and Port numbers for Storage SCP and Storage SCU in chapter 4 4 3 services 209804 rev 2 Instrumentarium Dental 119 5 Configuring DICOM 120 DICOM settings 1 xl Local DICOM parameters Local Application Entity Title 2475586 DICOM Local Port Number 106 File Folder Filename C Documents and Settings All Users Application D Browse Advanced Click OK or Apply to save the configuration parameters Temp File Folder The folder on the local hard drive where the retrieved images are saved temporarily before saving them to database can be configured here Storage SCP page Advanced button The Log Files and Performance pages provide parameters for adjusting the low level settings of the DICOM network services There are similar settings for all the DICOM network services See chapter 5 8 Log File and Performance Settings Instrumentarium Dental 209804 rev 2 209804 rev 2 5 Configuring DICOM 5 8 Log File and Performance Settings The Log File Page allows the configuration the database the error log file or the stor
46. Select the feature you want to install Please select the feature that you want to install CLINIVIEW Quick Install Standalone or small network server No Volumetric Tomography or DICOM features CLINIVIEW Network Client Client without database No Volumetric Tomography or DICOM features S505 CLINIVIEW Advanced NSTIUMEHDANUM fft Standalone or small network server A Includes Volumetric Tomography and DICOM features tLSoces CLINIVIEW Manuals Installshield Cancel 209804 rev 2 Instrumentarium Dental 4T 2 Software installation 4 Select CLINIVIEW software only Select database Database options Description C Install CLINIVIEW database CLINIVIEW software setup database is not installed Connection is made to C Search existing MS SQL Servers existing CLINIVIEW patient and x ray image database INSTRUMENTARIUM Installshield Select Yes I want to install CLINIVIEW software then click Next Select Workstation Software option Select installation folder 2 INSTRUMENTARIUM Program installation folder C Program Files CLINIVIEW S Installshield 48 Instrumentarium Dental 209804 rev 2 2 Software installation 6 Select DICOM features to be installed and then click Next Select DICOM features Select DICOM features Descriptiorr This will install CLINIVIEW DICOM features Please note that you need to have DICOM l
47. Settings Device FootPedal Close after image snap C comi 0 seconds C coM2 Disabled 1 Capture Delay Delay 0 milliseconds Shortcuts Start Capture F4 v Shift Control Snap Image F5 f Shift Control End Capture F6 f Shift Control Normally the device is selected automatically Use Close after image snap slide bar to specify how many seconds a capture image stays top of the screen after capturing Use Capture Delay to prevent camera shake caused by button press It is the delay between IntraCam s button click and actual image capture Set the value in the Delay editbox of IntraCam s settings dialog Use Shortcuts to configure shortcut keys to start capture session snap image and end capture session The default values for the same are e Start capture F4 e Snap image F5 e End capture F6 Note The software supports Durr Dental s PC COM port connectable 3 button foot pedal Instrumentarium Dental 85 4 Driver installation 4 5 1 Video Format dialogs o Format Click Format to open the window Properties s VER Input Select the used Video Standard on Video Decoder tab These alternatives vary according to camera manufacturer and country Sharpness j qm i i i Adjust e g the brightness contrast hue and saturation These alternatives vary according to camera manufacturer 86 Instrumentarium Dental 209804 rev 2 4 Drive
48. TARIUM Welcome to License Activation Wizard Start trial or activate your license Begin using the product right away You may use the product up to 30 days without restrictions Click Finish CLINIVIEW can now be used for a maximum of 30 days When the trial license is activated it will automat ically expire after 30 days When the CLINIVIEW li cense is activated it does not cancel the trial license If trial license expires and a proper license has not been activated CLINIVIEW cannot be started Note When CLINIVIEW is used in the 30 day trial mode the Continue using trial window will appear each time CLINIVIEW is started Click the Continue trial button to continue the trial pe riod and use the software Your license will expire soon Continue using the expiring license or activate a permanent license Your license will expire after 30 days Instrumentarium Dental 209804 rev 2 209804 rev 2 3 Licensing CLINIVIEW 3 2 1 Licensing CLINIVIEW network 3 2 1 1 Activating CLINIVIEW network license Open License Manager tool in the computer where the Licensing Server has been installed To open License Manager select Start Instrumentarium Dental gt License Server License Manager Activate the Network License using the License Manager tool See chapter 3 4 License Manager Note The License Manager tool is delivered with both CLINIVIEW and License Server You rec
49. Tools folder in the software installation directory e g Program Files CliniView Database Tools The backup of the CVDATA folder including all subfolders can be made with any backup software and media type that the user has available Note This describes a procedure as an example to back up both the database tables and medical images Therefore ensure that all the CVDATA contents fit in the backup media it can be up to several gigabytes The necessary backup software is supplied with the backup device e g Magneto optical tape drive Instrumentarium Dental 129 6 Software database 130 6 2 1 Making instant backup from the software database Note f you use 32 bit SQL Server in 64 bit Windows do the following modification in BackupDB bat before exe cuting it Replace instance of Program Files with Program Files x86 in OSQLEXE definition Note It is highly recommended that all users are logged off the software database Note Running the backup restore batch files under the Tools directory could fail under Windows Vista and later op erating system due to missing permissions to create files under the Program Files directory In such cases the prob lem can be circumvented by e g adjusting permissions or moving the Tools folder under some other directory 1 Run BackupDB bat located in the Tools folder men tioned in the beginning of the chapter In Windows 7 run file in command line opened with Run as admin
50. VIEW Network Client Select Features Select the feature you want to install Please select the feature that you want to install CLINIVIEW Quick Install Standalone or small network server No Volumetric Tomography or DICOM features CLINIVIEW Network Client Client without database No Volumetric Tomography or DICOM features peer CLINIVIEW Advanced INSTRUHSNTRNIUM T Standalone or small network server Includes Volumetric Tomography and DICOM features CLINIVIEW Manuals Installshield 4 Click Browse to search for the database server on the network Select the appropriate database server and click Next to continue Note If an error is shown replace the computer name with the IP address of the server and click Next Select Database Server Select database server you want to install to Select or enter the database server where remote CLINIVIEW database resides E g enter the value under key hostname from server s DataSource ini Database Server 192 168 136 128 CLINIVIEW e INSTRUMENTARIUM Installshield 26 Instrumentarium Dental 209804 rev 2 2 Software installation 5 Review the license agreements and click Yes to accept the license terms and continue with the installation License agreements Do you accept the following license agreements CLINIVIEW software license View license Microsoft Direct runtime license View license e INSTRUMENTARIUM Installshield 6
51. X Scan eXam OPD OCD image capturing requires PCl driver version 2 3 4 7830 or later which is included on the installation media Windows 2000 Windows XP Professional and Windows Vista Business Windows Vista Ultimate Windows Vista Enterprise Windows 7 Professional Windows 7 Ultimate Windows 7 Enterprise Windows 8 Pro are registered trademarks of Microsoft Corp Note Refer chapter 1 4 for details about service packs Instrumentarium Dental 209804 rev 2 2 Software installation 2 Software installation 209804 rev 2 X ray device Software installation requires at a minimum a database for patient and image data client software for image capturing processing and viewing at least one imaging device imaging plate reader intra oral sensor or extra oral x ray unit and license server These software components can be installed in one workstation standalone or separate workstations network installation depending on the system needed Standalone In a standalone system all software components are installed in the same workstation connected to the imaging device See chapter 2 1 to install a standalone system CLINIVIEW client Image acquisition Image viewing and management PMS integration DICOM services optional VT client optional CLINIVIEW database VT reco server optional Modality workstation 3D visualization software op
52. XCliniView D atabase Installshield 8 If you wish to read Readme file click Yes 209804 rev 2 Instrumentarium Dental 139 7 Upgrading the software 9 Select if you wish to restart recommended the work station now and select if software will automatically start after restarting the workstation InstallShield Wizard Complete Setup has finished installing CLINIVIEW 10 2 2 on your computer Before you can use the program you must restart your computer INSTRUMENTARIUM No will restart my computer later Remove any disks from their drives and then click Finish to complete setup After the reboot log in with administrator privileges to finish the installation IV Launch CLINIVIEW after finishing Finish Cancel 10 11 12 13 14 140 Select software default language click OK to continue Note Software language can be changed at any time within the software from the Tools menu Languages To activate the license see chapter 3 2 Licensing CLINIVIEW software The installed devices window will be displayed Select the devices to be connected to this workstation and click OK to enable the devices If the selected device requires a gain file the software will prompt to open the GainInstaller tool Browse to the location of the gain file s and install them using the Gainlnstaller tool Note Only certain devices require a gain file Software is ready for use A
53. aeaa 87 45 3 Video Input dialog opere eni itt auc 88 4 5 4 Link the software to Intra camera event seen 89 5 Configuring DICOM iaceo reete erint es tensa satable suds beceuces ts cane cadevuescesdcevaceeneds 91 8 Bid General PAGS et vcsivasticent ceeded vastus mE 92 5 1 1 DICOM License nurmbDer iet otto Ond udtetei ae 93 5 1 2 Retired Command Elements eeeceeceeeecenseeteee recenter 93 52 SOP Class CoHfgurelibrn ce recedet rotto edu ce ed ete 93 5 3 Morklist oonfigaratlort see rar s se a nd Lote tear ote aver tenet 95 53 1 WorkList SCP BOX x iu eene uiae a aaar dise n edi tutu ue auae ashamed 96 5 3 2 Search for worklist items by date sssssseeeeeeeeee 97 9 99 Modalities BOX 2 tod tette tea dieit treni edad 97 5 3 4 Scheduled Station iaceo niente ee pipa IRI uon eee 97 5 3 5 Worklist Page buttons os onoie cae ooo eer tret ote Pee eser oe oia too etd Deae repete 98 5 5 5 Other OpHOEIS s zai rr nec rir re atico ec E ero re afa 99 5 4 Storage and Storage Commitment configuration esesesssssssss 101 5 4 1 Storage page Destinations 2 22 cccccccecceeeceeeeeeeeesessesseessceteeeeeneneeeeee 102 5 4 2 Storage page Attributes List buttons seesssseseesssss 106 5 4 3 Storage Commitment settings esee tenere nneieee ette Ecran 108 5 5 Print configuration eR E 110 5 5 1 Print pag
54. age service log file destinations and parameters to be changed Configuration Database field Allows the database name Data Source Name and location Filename to be changed Key in the specified path directly or click Browse and select the required name and location Write ODBC When the ODBC check box is selected anew DSN entry is to be inserted into the system DSN list Re fer to ODBC and Microsoft Windows documenta tion for details Error Log File field Allows the errors log file name and its maximum size in bytes to be selected Storage Service Log File field Allows the Storage Service message log file to be selected and configured The log file name maxi mum size the line length and log message levels are configurable x Log Files Performance Error Log File Filename Maximum size lines 500 r Activity Log File Filename C Documents and Settings All Users 4 Browse Maximum size 1000 E Use error log file m r Message Log File Filename C Documents and Settings All UserslA Browse Maximum size lines 100000 a Line length 78 z ing Messages Levels Blank fil log file m Error level v Warning level v Info level Backup old log file m Historical log files 1 Instrumentarium Dental 121 5 Configuring DICOM The Log message levels are as follows Error level This level logs error messages These messages ma
55. al 173 12 Software license 174 confidentiality shall survive the termination of the Soft ware License 5 2 You agree not to decompile reverse assembles or reverse engineers the Software or otherwise attempt to derive source code from the Software The prohibition in the foregoing sentence shall apply only to the extent permitted by applicable law When information of the in ternal structure of the Software is necessary in order to obtain interoperability of the Software with other soft ware programs you shall immediately contact Licen sor Disclaimer of Warranties 6 1 To the maximum extent permitted by applicable law Licensor and its suppliers provide the SOFTWARE lt as is gt and hereby disclaim all warranties and condi tions either express implied or statutory including but not limited to any if any implied warranties or condi tions of merchantability of fitness for a particular pur pose compatibility of lack of viruses of accuracy or completeness of responses of results and of lack of negligence or lack of workmanlike effort all with regard to the SOFTWARE and any part thereof and the provi sion of or failure to provide support services There is also no warranty or condition of correspondence to de scription or non infringement with regard to the SOFT WARE or any part thereof Licensee shall bear the entire risk as to the quality or compatibility of or arising out of use or performance of the SOFTWARE
56. ally installed in a dedicated server with a server operating system A network installation has multiple modality workstations connected to several imaging devices for image capturing and may also have multiple dedicated viewing stations for image viewing and diagnosis If network licenses are used the license server is installed at the server Note The license server computer must be running at all times to provide licenses to other workstations in the net work 14 Instrumentarium Dental 209804 rev 2 2 Software installation ABAISS SSUdIIT guoi do 427425 02241 1A sseqe3ep 4 M3IAINIT2 Ja8AJ9S guor3do ssemyos uoigezijensi gg UPI LA ss21 425 OJIA uaw euew pue Jumala e3eul s USUS a MIIAINITO UOHne S LIO UONRYS m UONRYS OM SUIM IA SUIM IA SUIM IA aoiAap LJ X J14 p LJ X jeucizdo suemyos uorezijensia gg uopg323ul SN de UOLIS M UuoneJs440 A jueuieSeueu pue Jumala seul uonisinb e 23e8ul 3451 2 4 M3IAINTTO AupepotW AupepotW 15 There are three installation options available Quick Instrumentarium Dental Installation options Network and Advanced 209804 rev 2 2 Software installation Quick install is an easy option to install software for a standalone workstation or a small network modality workstation It includes software for image capturing processing and storing software client image acquisition drivers image database and local license se
57. alog There is no automatic polling but the C Find query is sent only when the user initiates the search This mode is potentially the slowest but provides the most control for the user The Verify Button See the Storage Page in this manual for more information 5 3 2 Search for worklist items by date Set the number of day s before and after today that are taken into account in worklist search Using values 0 and 0 here means that only worklist items scheduled for today are queried from the worklist server This setting is not available in the Search from worklist SCP mode 5 3 3 Modalities Box Checking the modality boxes allows the chosen modalities to be retrieved from the Modality Worklist SCP Modality SOP Class Name DX Digital Radiography lO Intraoral Radiography PX Panoramic X Ray CR Computed Radiography XC External camera Photography CT Computed Tomography Other User defined modlity can be left empty in which case modality is not used as a search criteria Also several modalities can be defined Separated by a space This setting is not available in the Search from worklist SCP mode 5 3 4 Scheduled Station This option can be used to retrieve only the items scheduled for the specified workstation AE Title This setting is not available in the Search from worklist SCP mode Instrumentarium Dental 97 5 Configuring DICOM 98 5 3 5 Worklist Page buttons Columns button Define the attribut
58. alone License Server trenes 52 2 4 Standalone with Volumetric Tomography sseeeee 53 3 Licensing CLINIMEW uec 61 3 1 Important licensing information careant enc eee ree eee eee nare neo eene edite eroRcn 61 3 2 Licensing CLINIVIEW standalone eeeeeeeeee eene 62 3 2 0 1 Trial period activation uu ome mo HIE o vpn et EXT REXOrERECEOE DR HER 70 3 2 1 Licensing CLINIVIEW network eeeeennm 71 3 2 1 1 Activating CLINIVIEW network license 71 3 2 1 2 Configuring workstations to use CLINIVIEW network license 72 32 2 License Mariage 35e eti et acs dete sateen aioe 73 4 Driver mnstallaliQIiaii ero tte ono ptu acs emcee trata a Aa Ee td eee tes 77 TT Device Hel aa rr Loa undi le ee e ce oe eR rol tne ee eee 77 4 2 NVIDDA GPIVBIS iir eR cc nk eth eant ne X a hm desees aeu au eeu en e tee 77 4 3 OPD OCD PCI driver installation cease 77 4331 POldryeriupdalesssectoon rst ru pet casas e ra onal pt abi a ebbe end eI 81 4 3 2 Uninstalling the driver o onte ae pee Up aerea attis uen 83 Z4 ONIN A Boose cca ce alee a o omm SN Lei BURE E e e a ee POI We EcL ned 84 4 5 Intraoral camera installation ccc cccceeeeeeeeeeeeeeeeeeeeeeeaaaaaaeeeeeeeeeeeeeeeeeeeeeeeeeeees 84 4 5 1 Video Format dialogs t oi d ul oa dme ng fo ue dot aded 86 4 5 2 Mided Source dialog uei rotated ectetur deti bep e cpa
59. an image automatically 1 Open Scanners and camera properties in the Control Panel Select your Intra Camera from the devices list and click Properties Scanners and Cameras Properties 2 xl Devices ES The following scanners or cameras are installed Logitech ClickSmart 510 Add Remove Troubleshoot Properties Cancel 2 Select Events Tab DXM USB 2 0 Properties 2 xl General Events Color Management DXM USB 2 0 Camera events O E DM Still Image Application O R imaging C K j Photoshop Elements T Disable device events Cancel Apply 209804 rev 2 Instrumentarium Dental 89 4 Driver installation 90 3 Select New Picture Requested from the Camera Events list and Enable CLINIVIEW option from the lower list 4 Change the Camera event to Snapshot Button Pressed and Enable CLINIVIEW option 5 Before the configuration is valid reboot your PC Note If the Events tab is not displayed then this feature is not available for the selected Intra Camera Instrumentarium Dental 209804 rev 2 5 Configuring DICOM 209804 rev 2 Before using the software DICOM features the DICOM option must have been installed and the system should be configurated Note The software DICOM is a licensed feature A DICOM license key must have been given in either during the soft ware client installation or in CLINIVIEW Manager applica tion after the insta
60. aoral sensors Express Orthopantomograph OP30 OP300 OP100 D OP200 D and Orthoceph OC100 D and OC200 D digital units KaVo Scan eXam Pan eXam and Pan eXam Plus digital units and intraoral video cameras Images can also be imported from other digital sources The software stores images and patient information in a SQL database and provides tools for image archiving This installation manual covers the installation of the software Standard and DICOM versions The user manual describes how to use the software See the equipment manuals before installing or using the equipment See the Windows manuals for further information about the Windows environment With the software you can perform the following operations assuming that all the equipment is ready for use Create a new patient and store patient information in a database Capture and store digital X ray images with expo sure values from the device Capture and store intraoral photographs Export and import digital images Process images to enhance their diagnostic value with dental specific tools Analyse the image with application specific meas urement tools Build an environment with multiple workstations using a database shared over a network Printing images and image information Capture 3D images and launch 3rd party image analyzing and planning tools Instrumentarium Dental 1 1 Introduction 1 2 The software allows to i
61. atabase along with all the image data is now re stored Instrumentarium Dental 131 6 Software database 132 6 3 Restoring database to a new installation and or location Note This procedure has to be applied whenever MS SQL Server database has been re installed Otherwise the new database installation does not read any of the existing data or images but is running the newly created empty database 6 3 1 How to restore a database to another installation or new location Note f you use 32 bit SQL Server in 64 bit Windows do the following modification in ImportDB bat before execut ing it Replace instances of Program Files with Program Files x86 in OSQLEXE and SQLCMD definitions Note n Windows Vista and later run the files Back upDB bat and ImportDB bat in command line opened with Run as administrator If you already have an up to date backup of the whole image folder CVDATA and you have a matching pidbmsde dat file there in the Backup folder skip step 1 1 Make backup from the existing database source by running the backup batch file location e g C Program Files CliniView Database Tools BackupDB bat Username Password admin admin by default 2 Make a backup of the image folder e g C CVDATA INCLUDE ALL CONTENTS 3 Install the software database to the new computer des tination and restart the computer when asked NOTE For the system to work correctly the Database tables and Databa
62. athWorks 2 25 2013 262MB 74 amp Microsoft SQL Server 2008 R2 Microsoft Corporation 2 25 2013 d Microsoft SQL Server 2008 R2 Native Client Microsoft Corporation 2 25 2013 609MB 105125000 amp Microsoft SQL Server 2008 R2 Setup English Microsoft Corporation 2 25 2013 324MB 105125000 H Microsoft SQL Server 2008 Setup Support Files Microsoft Corporation 2 25 2013 216MB 10127310 3 Microsoft SQL Server Browser Microsoft Corporation 2 25 2013 900MB 10 51 2500 0 H Microsoft SQL Server VSS Writer Microsoft Corporation 2 25 2013 360MB 10 51 2500 0 Microsoft Visual C 2008 Redistributable 1649 03 Microsoft Corporation 2 25 2013 252KB 9 030729 icrosoft Visual C 2008 Redistributable x649 03 Microsoft Corporation 7 31 2012 788KB 9 0 30729 4148 icrosoft Visual C 2008 Redistributable x86 9 0 3 Microsoft Corporation 2 25 2013 234KB 9030729 icrosoft Visual C 2008 Redistributable x86 9 0 3 Microsoft Corporation 7 1 2012 596KB 9 0 30729 4148 Mf OpenCL 11 support for Intel Core processor fa Intel Corporation 2 25 2013 GA instrumentarium Dental Product version 10224 Support link www instrumentariumdental com Help link wwwinstrumentariumd Size 668 MB 3 The software Setup Maintenance mode starts Select CLINIVIEW Add ons and click Next r F nm CUNIMEW 10 2 2 InstallShield Wizard E Maintenance mode This program lets you modify the current installation Click one of the options below CLINIV
63. ation Select this method if this computer is not connected to the Internet Back Nen Cancel 209804 rev 2 Instrumentarium Dental 65 3 Licensing CLINIVIEW 66 The Offline activation request window opens Select Generate request An offline activation request must first be generated and then sent to Instrumentarium Dental Click Next Offline activation First generate activation request file and then process the received response file Generate request Process response The Registration page appears Enter all the registration information It is important to enter the license owner contact information correctly Mandatory fields are marked with an asterisk When you have entered all the required information into the Registration page click OK Registration Registration is required for activation Please provide license owner information below Accur information helps us to deliver timely after sales support Company Information i Instrumentarium Dental 209804 rev 2 3 Licensing CLINIVIEW 5 The Offline activation window appears Enter the soft ware activation key which is printed on a sticker at tached to the CLINIVIEW CD case into the appropriate field Click Next CLUNIVIEW License Activation INSTRUMENTARIUM Offline activation Please enter activation key Enter activation key P123 1234 1234 123 Back Cancel 6 The Sav
64. atures you do not want to install amp ViDatabase Common Install client VT components M Database engine that provide access to M Database sharin reconstruction tasks Requires 3 ng alocal or remote database B M Client Common MV Image capturing Client touch panel mode instrumentarium CIDICOM Print CI Worklist Description Storage C Query Retrieve v MVT Reconstruction Server 0 00 MB of space required on the C drive 24732 33 MB of space available on the C drive Installshield 5 System is successfully modified a restart is recom mended 146 Instrumentarium Dental 209804 rev 2 209804 rev 2 8 Adding features 8 3 2 Adding options using Add ons You can add a new option e g License Server DICOM at any time after the installation 1 Start Control Panel Programs and Features 2 Select CLINIVIEW Click Change Control Panel Home gt Uninstall or change a program View installed updates To uninstall a program select it from the list and then click Uninstall Change or Repair Bj Turn Windows features on or off Organize Uninstall Change Name Publisher Installed On Size Version iS CuNMEW 10 2 2 Instrumentarium Dental 2 25 2013 668MB 10224 iam PaloDEx Group 2 25 2013 495MB 4134226 SJINSTRUMENTARIUM DENTAL License Server Instrumentarium Dental 2 25 2013 490MB 1003506 MA MATLAB Component Runtime The M
65. be assigned to an attribute This includes the data type as well as its format The Value is the variable to which the value stored in the attribute is assigned To change or remove one of the list items first select the item in the list and then click the corresponding button m C Find Request tk remove The edit or remove dialog appears with the fields containing the data of the item to be changed or removed DITEESO x Tag VR String Y Value PATIENT Cancel After the changes click OK to accept them To remove an item the following confirmation message appears CT x x Are you sure you want to delete the Tag 0008 0052 Up and Down buttons These buttons are located in the bottom left hand corner of the advanced dialog in the C Find Response group box They can only be used with that list Instrumentarium Dental 209804 rev 2 5 Configuring DICOM C Find Response 0010 0010 0010 0020 0008 0054 With the Up and Down buttons change the order of the list items Select the item to move up or down the list and then click UP DOWN 5 6 2 The Log Files and Performance pages The Log Files and Performance pages provide parameters for adjusting the low level settings of the DICOM network services There are similar settings for all the DICOM network services See chapter 5 8 Log File and Performance Settings 5 7 Storage SCP Storage SCP page The Storage
66. bject to all re strictions and protections provided for under the appli cable copyright and other laws and treaties Except as otherwise may be agreed by Licensor in writing you have no right to reproduce or otherwise duplicate the Software or any part thereof for any purpose or to allow any third parties to do the same without the prior written consent of Licensor Notwithstanding the above you may make one copy of the Software for back up pur poses provided that such copy and the media thereof shall include the same copyright and other proprietary notices or legends included on the Software when it was shipped to you You agree not to remove any Soft ware identification copyright notices or other notices or proprietary restrictions from the Software Confidentiality 5 1 The Software contains proprietary and confidential information of Licensor and its suppliers and is consid ered by Licensor and its suppliers to constitute valuable trade secrets You agree to hold the Software in confi dence and protect the Software with at least the same degree of care with which you protect your own similar confidential information but in no event less than a rea sonable standard of care You agree that your officers and employees shall protect the confidentiality of the Software and all confidential and non public informa tion relating thereto and shall not disclose such infor mation to any third party This obligation of Instrumentarium Dent
67. btain from the hospital administrator Polling interval sec Specifies the polling interval in seconds the software makes queries to the Modality Worklist SCP If O seconds is set here no polling is done The user has to update the contents of the worklist dialog with the Refresh button when needed This setting is not available in the Search from worklist SCP mode Refresh Timeout This value specifies the timeout that the application waits for the worklist service to finish the refreshing The value is given as seconds Search method If Refresh from worklist SCP mode is selected the manual refreshing of the worklist cause the worklist query C FIND to be sent to the Worklist SCP This is the recommended option for cases where the C FIND operations are fast or the user wants full control of the refreshing If Refresh from local database mode is selected the manual refreshing does not send a Worklist query but only reads the latest data from the local worklist database This local database has the results of the worklist polling done on the background Note make sure the polling is enabled This is the recommended option for cases where the C FIND operations take a relatively long time Instrumentarium Dental 209804 rev 2 209804 rev 2 5 Configuring DICOM If Search from worklist SCP mode is selected the Worklist SCP is searched directly for worklist items using only the filters provided in the worklist search di
68. by acquiring an image according to de vice user manual or quick guide Configure the desired user settings for the software See user manual for details Close the software Start License Server manager and activate the floating network license See Chapter 3 3 1 Activating CLINI VIEW network license Instrumentarium Dental 209804 rev 2 2 Software installation 16 Optional If the local network does not support DNS or WINS you must change File Server to use the server s IP address in place of its host name To do this open CLINIVIEW Manager Click File Server Config and enter the user name and password when prompted Enter the IP address of the server and click Save Close CLINIVIEW Manager File Help CLINIVIEVV Manager Archive Images Database File Server Configuration eem Q Create User management IP or computer name WIN D938C86MA58 Q Restore i Database backup fl X Save Close I Trash licence location logs Exit Report INSTRUMENTARIUM 2 2 2 Small network viewing workstation 1 Insert software DVD into DVD ROM drive 2 If the InstallShield Wizard does not appear after a few moments browse to the software DVD and double click CLINIVIEWSetup exe to begin installation Note If the User Account Control window appears you must allow changes to continue installation 209804 rev 2 Instrumentarium Dental 25 2 Software installation 3 Select CLINI
69. cense shall not be considered a waiver of any subsequent breach of that provision or as a waiv er of any other provision hereof Instrumentarium Dental 175 12 Software license 176 Instrumentarium Dental 209804 rev 2
70. ciation request 30 zd Association Response 15 xd Connection Rm Release I5 7M Write 15 ed Inactivity 15 Buffers Work buffer 28672 4 Send buffer 29696 E Receive buffer 29696 i a E N PDU max length Maximum size of Protocol Data Units that can be sent or received by the software DICOM Timeouts box Allows various timeouts in seconds to be set If the application is running in a multi tasking environment the process is blocked during this waiting period and the system processor is available for other processes If all the timeouts are set to 0 this is equivalent to polling as DICOM returns immediately whether a message has been received or not Association Request The waiting time for association request or for the peer to shut down an association A Association Response The waiting time for a reply to an associate re quest Connection The waiting time for a network connection to be ac cepted Release The waiting time for a reply to an associate re lease Write The waiting time for a network write to be accept ed 209804 rev 2 Instrumentarium Dental 123 5 Configuring DICOM nactivity The waiting time for data between TCP IP packets Buffers This box allows various buffers to be configured to improve performance Work Buffer This option sets the buffer size before DICOM ap plication stores the data or passes it Setting higher values for
71. computer is being replaced Note that trial licenses cannot be returned to INSTRUMENTARIUM DENTAL license server Select the license you wish to return from the list and click the Return button The return operation can be done using online or offline methods Select Online return if the computer is connected to the Internet Offline return generates a request file and processes a response file the same way as in Offline connection After successful return operation you can then activate the license in another computer Repair license button If the license Status is BROKEN for example the program has been corrupted select the license click Repair and then select online or offline repair depending on whether the computer is connected to the Internet or not Settings button Allows you to select the language of the license manager Also shows the licence server addresses These should not be modified unless instructed to do so Instrumentarium Dental 209804 rev 2 209804 rev 2 3 Licensing CLINIVIEW License ManagerLicense users s License usage s INSTRUMENTARIUM Features in selected license CLINIVIEW Licenses with selected feature Product Version Activation key Expiration 1 CLINIVIEW 10 20 User 102 PERMANENT Users of selected feature Name Hostname Count 1 pmultil 7a50f1 1 Licenses available 19 Total license count 20 C Refresh Close Note This feature i
72. crosoft Visual C 2008 Redistributable x86 9 0 3 Microsoft Corporation 2 25 2013 234KB 9 30729 E Microsoft Visual C 2008 Redistributable x86 9 0 3 Microsoft Corporation 7 1 2012 SOS KB 90307204148 Mi OpenCL 1 1 support for Intel Core processor fa Intel Corporation 2 25 2013 fs Instrumentarium Dental Product version 10 2 2 4 Support link www instrumentariumdental com Help link www instrumentariumd Size 668 MB 3 The software Setup Maintenance mode starts Select CLINIVIEW Advanced Modify and click Next r E 7 CUNIVIEW 10 2 2 InstallShield Wierd mm Maintenance mode This program lets you modify the current installation Click one of the options below CLINIVIEW Add ons Add DICOM features Volumetric Tomography features or License Server CLINIVIEW Advanced Modify Add or remove features CLINIVIEW Repair INSTRUMENTARIUM S ji Reinstall all previously installed features CLINIVIEW Remove e Remove all installed features CLINIVIEW Manuals 209804 rev 2 Instrumentarium Dental 145 8 Adding features 4 See already installed features in the Select Features di alog Add features by selecting the needed features e g DICOM Click Next CUINVIEW 1022 InstallShield Wizard ns ES Select Features Select the features setup will install Select the features you want to install and deselect the fe
73. ct DICOM features No DICOM components V DICOM Worklist INSTRUMENTARIUM IV DICOM Print IV DICOM Storage IF DICOM Query Retrieve Description This will install CLINIVIEW DICOM features Please note that you need to have DICOM license to use these features Installopield 10 Select Yes I want to install Volumetric Tomography and then click Next Select Volumetric Tomography Volumetric Tomography No do not want to install Volumetric Tomography e INSTRUMENTARIUM Description This will install Volumetric Tomography Installshield Instrumentarium Dental 209804 rev 2 209804 rev 2 2 Software installation 11 Select Yes want to install RecoServer and then click Next Select RecoServer Volumetric Tomography Reconstruction Service Description ee This will install Volumetric Tomography RecoServer No do not want to install RecoServer e INSTRUMENTARIUM Installshield 12 Review the license agreements and click Yes to accept the license terms and continue with the installation CLINIVIEW 10 2 2 Insta License agreements Do you accept the following license agreements CLINIVIEW software license View license Microsoft Direct runtime license View license Microsoft SQL Server Express license View license ER wwsteuentariom Installshield Instrumentarium Dental 57 2 Software installat
74. ctivelmagelndex to see the number of the active image of the active image series e g VT slice series See InstrumentariumSOREDEX web page to get additional information about PMS interface Instrumentarium Dental 169 11 Using practice management interface 170 Instrumentarium Dental 209804 rev 2 12 Software license 12 Software license 209804 rev 2 THIS DOCUMENT IS A LEGAL AGREEMENT BETWEEN YOU AS THE lt LICENSEE gt AND PALODEX GROUP OY THE lt LICENSOR gt GOVERNING YOUR RIGHT TO USE THE CLINIVIEW SOFTWARE Software IF YOU AGREE TO BE BOUND BY THE TERMS AND CONDITIONS OF THE SOFTWARE LICENSE AND THIS PARAGRAPH PLEASE PRESS lt Agree AT THE PROMPT BELOW IN WHICH CASE YOU AGREE THAT THIS AGREEMENT IS ENFORCEABLE LIKE ANY WRITTEN NEGOTIATED AGREEMENT SIGNED BY YOU IF YOU DO NOT CONSENT TO THE SOFTWARE LICENSE AND THIS PARAGRAPH PLEASE PRESS lt Cancel gt AT THE PROMPT BELOW IN WHICH CASE THE SOFTWARE WILL NOT OPERATE AND RETURN THE SOFTWARE AND THE ACCOMPANYING ITEMS TO YOUR PLACE OF PURCHASE FOR A REFUND 1 Subject matter of the Software License This Software License governs the use of the Software Software means the software product specified above including new versions or updates of the Software made generally available to other licensees of such Software free of charge if any 2 Software License Grant 2 1 Licensor hereby grants you a non exclusive and non transferable license to use du
75. de licenses for computers on the local network 8 Select No I do not want to install CLINIVIEW soft ware Click Next to continue 209804 rev 2 Instrumentarium Dental 39 2 Software installation 40 9 Review the license agreements and click Yes to accept the license terms and continue with the installation License agreements Do you accept the following license agreements CLINIVIEW software license View license Microsoft Direct runtime license View license Gp isteuventariu Installshield 10 Review the installation settings and click Next to start installation process CLINIVIEW 10 2 2 InstallShield Wizard BS Start Copying Files Review settings before copying files Setup is ready to install CLINIVIEW to this computer with the following settings Current Settings Features selected a Database Destination folder C Program Files x86 CLINIVIEW Database media folder D INSTRUMENTARIUM CACVDATAN Installshield Instrumentarium Dental 209804 rev 2 2 Software installation 11 If you wish to view software release info Read me click Yes a InstallShield Wizard Complete Setup has finished installing CLINIVIEW 10 2 2 on your computer Before you can use the program you must restart your computer INSTRUMENTARIUM No will restart my computer later Remove any disks from their drives and then click Finish to complete setup
76. dy uses the software before the database connection has been completely reconfigured otherwise some data is saved to the old database 6 3 2 How to reconfigure Database connection ODBC 1 Open Start gt Settings gt Control Panel Switch to Classic View gt Administrative Tools gt Data Sources ODBC Select the System DSN tab Select CliniView and click Configure Select The new server CliniView from the list and click Next Bop m Instrumentarium Dental 133 6 Software database 134 5 Select With SQL Server authentication using a login ID and password entered by the user Also Connect to SQL Server to obtain default settings for the additional configuration options must be checked Write user name by default admin to the Login ID field and password by default admin to the Password field and click Next 6 Click Next again 7 Click Finish OK and OK 6 4 Renaming Database Computer There are certain steps that need to be taken when renaming computer which hosts the software database with database sharing These steps are done after the renaming is completed 6 4 1 Configuring the file server To configure file server to use the new computer name open CLINIVIEW Manager and select File File Server Configuration In the File Server Configuration dialog change the IP or computer name to match the new computer name and then click Save 6 4 2 Modifying Datasource ini
77. e Destinations toa oet etae 111 5 5 2 Print page Attributes List buttons sssesseeeeeeeee 114 5 6 Query Retrieve configuration acides cene nante ten eemececel 115 5 6 1 Query Options i v Lo nee Le eRai pd dote tet e e rd Ure hee Poids ct soi 117 5 6 2 The Log Files and Performance pages sseeseeseseeeeeeee 119 51 Storage SUE moi cast ee Se eet sh leur e e Hr ee 119 5 8 Log File and Performance Settings see 121 5 9 GIOSSANY P Pm 124 5 10 The software DICOM SOP Classes eeeeeeseeeeneeetennn enne nete tneneenne 126 Software database nni eue eden e ipee toa des bes a aeo dDecu es 127 6 1 Changing the software database location eseees 127 6 1 1 Changing database location by uninstalling local database using 127 6 1 2 Changing database location by modifying ODBC alias 128 6 1 3 Changing updated Standalone database to Network database 129 6 2 Database backup and restore ose duin Feto erre EE Deep ne Pn xt alone 129 6 2 1 Making instant backup from the software database 130 6 2 2 Restoring the software database from the backup 131 6 3 Restoring database to a new installation and or location 132 6 3 1 How to restore a database to another installation or new location
78. e components to ex ternal hard disks Note SQL Server installation requires that the Windows user account login name and the workstation name are different If the same name is used for both installation of SQL Server will not succeed Instrumentarium Dental 209804 rev 2 209804 rev 2 2 Software installation Note Installation creates required Firewall settings auto matically when image database components or License Server is installed Note Make sure that there are no pending or ongoing Win dows updates when starting software installation or up dates Display settings for the software The Windows display settings may have to be changed if the display is difficult to read after the software installation The display settings can be changed in the Windows Control Panel The recommended Windows display settings are e Desktop area at least 1024 x 768 pixels e Color quality Colors Highest 32 bit Instrumentarium Dental 17 2 Software installation 2 1 Standalone 1 Insert software DVD into DVD ROM drive 2 If the InstallShield Wizard does not appear after a few moments browse to the software DVD and double click CLINIVIEWSetup exe to begin installation Note f the User Account Control window appears you must allow changes to continue installation 3 Select CLINIVIEW Quick Install Select Features Select the feature you want to install Please select the feature that you want to install
79. e local laws and regulations on patient information softwares 11 1 Introduction The software uses an initialization file called CLINIVIEW ini Starting from CLINIVIEW 7 0 2 the file is installed in the software settings directory which is operating system specific Windows XP C Documents and Settings All Users Application Data CLINIVIEW Windows Vista C ProgramData CLINIVIEW However for compatibility reasons the software still uses the old CLINIVIEW ini file path in Windows XP if the practice management software continues to write data to it This file is installed in Y windir folder and windir is the folder where Windows is installed for example C Windows Windows XP Viewing System Variables e g Yewindir 1 Click Start point to Settings and then click Control Panel 2 Double click System 3 On the Advanced tab click Environment Variables 4 All current system variables and their associated val ues are listed in the lower list CLINIVIEW 8 1 or later installation directory and executable path are defined in Windows registry HKEY_LOCAL_MACHINE SOFTWARE Instrumentarium Dental CLINIVIEW ProgramDir CLINIVIEW path for example C Program Files CLINIVIEW ExeFile CLINIVIEW executable for example C ProgramFiles CLINIVIEW CLINIVIEW exe 209804 rev 2 Instrumentarium Dental 165 11 Using practice management interface 166 Earlier versions of the software before 5 0 u
80. e request window appears Select the location where you wish to save the activa tion request file and the help file for example the Win dows Desktop Click Next Offline activation Please save license activation request file Select location where request file and instructions will be saved C Users John Desktop 209804 rev 2 Instrumentarium Dental 67 3 Licensing CLINIVIEW 68 fs 10 The Request succeed window appears Click Show in folder button to locate the request file the file ends with xml Copy the request file and place it into any computer that is connected to the Internet You can also copy the help file same name as the request file but ends with txt if you wish to refer to the instructions during the activation process Offline activation Request file creation succeeded Created request file as C Users John Desktop CLINIVIEW_120619084902 xml Show in folder Process response Now using the computer connected to the Internet send the request file as email attachment to licensing in strudental com and wait for a response The typical response time is between 5 and 20 minutes When you receive a response email from Instrumentar ium Dental copy the file attached to the email and save it in the computer where CLINIVIEW was installed the response file ends with lic In the Request succeeded window click the Process response button Offline activation
81. eadme and start the software InstallShield Wizard Complete Setup has finished installing CLINIVIEW 10 2 2 on your computer IV View Readme INSTRUMENTARIUM Installshield lt Back Finish 7 Select software default language Click OK to continue Note Software language can be changed at any time within the software from the Tools menu Languages fi Language selection Select language English z OK 8 Toactivate the license select Activate Workstation li cense See Chapter 3 2 Licensing CLINIVIEW soft ware standalone Instrumentarium Dental 23 2 Software installation 9 The installed devices window will be displayed Select the devices to be connected to this workstation and click OK to enable the devices OP100D OC100D Cancel OC200D OP200DSmartNay OC200DSmartNayv SIGMA M small SIGMA M large SNAPSHOT sensor EXPRESS OP30 OP300 Panoramic OP300 Cephalometric OP300 3D 10 11 12 13 14 15 24 If the selected device requires a gain file the software will prompt to open the GainInstaller tool Browse to the location of the gain file s and install them using the GainInstaller tool Note Only certain devices require a gain file Software is ready for use A patient named Calibration Patient will be created and opened This patient can be used to store all calibration images for the installed de vice s Test installation
82. eated and opened This patient can be used to store all calibration images for the in stalled device s Test installation by acquiring an image according to de vice user manual or quick guide Configure the desired user settings for the software See User manual General Settings chapter for details Instrumentarium Dental 209804 rev 2 2 Software installation 14 If the software with be used with a Cone Beam 3D de vice install a 3D visualization software Launch options for the 3D visualization software can be configured on the Tools menu Cone Beam 3D Settings 15 If the software will be used with a Cone Beam 3D de vice install a 3D visualization software Launch options for the 3D visualization software can be configured on the Tools menu Cone Beam 3D Settings 2 2 Small network 2 2 1 Small network server 1 Insert software DVD into DVD ROM drive 2 If the InstallShield Wizard does not appear after a few moments browse to the software DVD and double click CLINIVIEWSetup exe to begin installation Note If the User Account Control window appears you must allow changes to continue installation 3 Select CLINIVIEW Quick Install 2 Select Features Select the feature you want to install Please select the feature that you want to install CLINIVIEW Quick Install Standalone or small network server No Volumetric Tomography or DICOM features CLINIVIEW Network Client Client without database N
83. ect the feature you want to install Please select the feature that you want to install 3 CLINIVIEW Quick Install Standalone or small network server No Volumetric Tomography or DICOM features a CLINIVIEW Network Client Client without database I No Volumetric Tomography or DICOM features CLINIVIEW Advanced Standalone or small network server Includes Volumetric Tomography and DICOM features INSTRUMENTARIUM CLINIVIEW Manuals Installshield 209804 rev 2 Instrumentarium Dental 43 2 Software installation 4 Click Browse to search for the database server on the network Select the database appropriate server and click Next to continue Note Ifan error is shown replace the computer name with the IP address of the server and click Next Select Database Server Select database server you want to install to Select or enter the database server where remote CLINIVIEW database resides E g enter the value under key hostname from server s DataSource ini Database Server 192 168 136 128 CLINIVIEW X Browse INSTRUMENTARIUM Installshield 5 Review the license agreements and click Yes to accept the license terms and continue with the installation License agreements Do you accept the following license agreements CLINIVIEW software license View license Microsoft DirectX runtime license View license 27 INSTRUMENTARIUM Installshield 44 Instrumentarium Dental 20980
84. ed de vice s 16 Test installation by acquiring an image 17 Close software 18 Configure the DICOM settings and test their functional ity See chapter 5 Configuring DICOM for more infor mation Instrumentarium Dental 51 2 Software installation 52 2 3 6 Standalone License Server In specific cases you may need to install a standalone License Server to a workstation or server Installing a standalone License Server is not supported by the Installshield Wizard provided with the software If you need to install a standalone License Server please follow these steps 1 Insert software DVD into DVD ROM drive 2 If the InstallShield Wizard appears click Cancel 3 Browse the install DVD media from My Computer and open the ISSetupPrerequisites folder 4 Double click the file IDLSsetup exe to start the License Manager installer Note f the User Account Control window appears you must allow changes to continue installation 5 Follow the onscreen instructions to install the License Manager 6 See chapter 3 Licensing CLINIVIEW software for instructions how to use the License Manager Instrumentarium Dental 209804 rev 2 209804 rev 2 2 Software installation 2 4 Standalone with Volumetric Tomography 1 2 Insert software DVD into DVD ROM drive If the InstallShield Wizard does not appear after a few moments browse to the software DVD and double click CliniViewSetup exe to begin installat
85. eduled Procedure Step Description is copied automatically to the Study Description tag Copy Requested Procedure Description to Study Description If this option is selected then Requested Procedure Description is copied automatically to the Study Description tag Study date time This setting controls how the Study Date and Study Time tags of a new study are filled when the study is created from a worklist item that lacks the Study Date and Study Time values Instrumentarium Dental 209804 rev 2 5 Configuring DICOM 5 4 Storage and Storage Commitment configuration The Storage page allows the storage and storage commitment parameters to be defined When this page is opened for the first time after installation two empty lists appear The Storage Destination List upper The Storage Attributes List lower Xi General S P Classes Worklist Storage Print Query Retiieve Storage sc Store images automatically when saving AE Title IP Address Pacs Pacs 127 0 0 1 104 JeFault Advanced Add new Edit Delete ag Name 5 5 Tye so Defaut Value _Addnew edt Storage Commitment Use Storage Commitment oes te The Storage Destination List upper Add storage servers to the storage server destination list e g DICOM ARCHIVES The Storage Attributes Tag List lower Add and edit DICOM Tag information to the tag list 209804 rev
86. ee readme txt for installation and upgrade instructions OPD OCD PCIe driver installation Note Install the PCI board driver according to the OP100 D OP200 D Installation manual PCI board and fiber optic cable installation Note Before installing a PCI driver the PCI board must be installed Refer to the instructions in the OP100 D OP200 D Installation Manual When the PC is switched on for the first time after PCI board installation Windows recognizes the hardware changes and launches a wizard Follow the instructions on the screen to install the PCI driver Note The screenshots are from Windows XP Instrumentarium Dental 77 4 Driver installation 78 1 Windows recognizes the hardware changes Select Install from a list Click Next Found New Hardware Wizard Welcome to the Found New Hardware Wizard This wizard helps you install software for PCI Device If your hardware came with an installation CD lt gt or floppy disk insert it now What do you want the wizard to do Install the software automatically Recommended 9 Install from a list or specific location Advanced Click Next to continue 2 Select Don t search Click Next Found New Hardware Wizard Please choose your search and installation options 23 O Search for the best driver in these locations Use the check boxes below to limit or expand the default search which includes local paths and removable media The best dri
87. elete the attribute Instrumentarium Dental 107 5 Configuring DICOM 108 5 4 3 Storage Commitment settings The Storage Commitment feature can be enabled or disabled with the check box control Storage Commitment IV Use Storage Commitment Local Application Entity Title Pacs Local Port Number 106 Advanced Automatic delete for committed images no automatic delete hed e oem When enabled both the storing of images and requesting commitment for the images use the software Storage SCU Application Entity The details of this AE must be configured AE Title and Port number Contact the local system administrator to get these values Note Do not use the same AE Title and port number as in Storage SCP Automatic delete for committed images When the Storage Commitment feature is enabled an automatic image deletion can be defined Only the images that are successfully committed are affected by this feature If the patient is left with no images after the image deletion the patient is also deleted Log entry of the deletions will be made into the System Log see chapter 9 4 4 System Logs All deleted images are put into the Trash see chapter 9 4 3 Trash from where they can be either restored or permanently deleted The following options are available for automatic deletion no automatic delete delete immediately after commitment delete 12 hours after commitment delete 24 hours after commitmen
88. ense and network license is installed using separate License Manager tools see chapter 3 4 License Manager for more information When the CLINIVIEW network license has been activated additional viewing workstations can be configured to use the network license see chapter 3 3 Licensing CLINIVIEW network how to activate a network license and how to configure workstations to use the network license Instrumentarium Dental 61 3 Licensing CLINIVIEW 3 2 Licensing CLINIVIEW standalone Online connection The computer is connected to the Internet 1 When the CLINIVIEW is opened for the first time a li cense activation request window appears Select Activate workstation node locked license E CUINIVIEW License Activation 00 INSTRUMENTARIUM Welcome to License Activation Wizard Start trial or activate your license Start trial now Begin using the product right away You may use the product up to 30 days without restrictions Enter activation key to activate the product on this computer Use network license Network licenses can be used from any workstation Network licenses are returned automatically to local license server after closing the software 62 Instrumentarium Dental 209804 rev 2 3 Licensing CLINIVIEW 2 The Select activation method window appears Select Online activation and then press Next i J INSTRUMENTARIUM Select act
89. ersion and the list of services is empty The results of the communication between entities can be printed or saved To save select File Save as or click Save To print select File Print or click Print Instrumentarium Dental 105 5 Configuring DICOM 106 5 4 2 Storage page Attributes List buttons If the focus of the window is in one of the destinations in the storage destination list only Add New is enabled Once the focus the line is selected is put into one of the attributes in the storage attributes list the rest of buttons are enabled DICOM settings Es General S P Classes Worklist Storage Print Query Retrieve Storage SCP IT Store images automatically when saving Copy slot title to Image Comments 0020 4000 when storing an FMS Destination AE Title IP Address Port Number ler Set as Default Advanced Add new Tag Name Type Default value Storage Commitment Use Storage Commitment Cancel pply The Attributes list includes default attributes for the DICOM application Add and edit the attributes or delete them from the list Attributes list Add new button To add a new attribute to the storage attribute list click Add New The Add New Tag window appears ada new Taa x Tag 00041130 File set ID Type Replace if empty Default cma Instrumentarium Dental 209804 rev 2 209804 rev 2 5 Configurin
90. es and the order in which they appear in the Worklist window in the Set Columns dialog Click Columns and the Set Columns window opens The Set Columns window is divided into two lists 1 Hidden Attributes List 2 Shown Attributes List m Attributes Charset Scheduled procedure ster Scheduled Station AE Title Sched procedure start d Sched procedure start tir Sched Physician s Name Sched procedure descript Sched procedure Locatiot Scheduled Item code Code value Sched proc Coding Scheme designato al Pre Medication Sched procedure ID Req contrast agent Req procedure ID Req procedure Descriptic gt Dan nraredure code 4 gt Shown Attributes Patient s name Modality Sched Station name gt Accession number aj Patient s ID Cancel The Shown Attributes list includes the attributes that appear in the software Worklist window The attributes in the hidden attributes list does not appear in the window To move the attributes from one list to another Click on the attribute to move the attribute chang es color Click the arrow to move the attribute in the direction required or Click on the attribute to activate it Without releas ing the mouse button drag the attribute to the other list or within the list to change the place of the at tribute then release the mouse button drag and drop Note All the changes made in the Columns
91. essly provided for herein or authorized in advance by Licensor in writing and ii the renting or leasing of the Software to another party Software License Limitations and Conditions 3 1 You hereby expressly agree that Licensor and its software suppliers own throughout the world all right ti tle and interest in the Software any copies thereof and all intellectual property rights contained or embodied therein including the ownership to any modifications or translations of the Software and that such ownership or rights shall not be transferred to you 3 2 With respect to any software of third party suppliers contained or to be contained in the Software you agree to the ownership of Licensor s suppliers hereunder and accept that Licensor s suppliers are direct and intended third party beneficiaries of this Software License with rights solely against you including without limitation on reasonable prior notice to and consent of Licensor the right to directly enforce and or terminate your li cense to use the Software Further you agree that Li censor s suppliers have no liability or obligations towards you arising out of or in connection with this Software License You agree to execute any such amendments to this Software License as may be re quired from time to time in order to comply with terms and conditions of any third party software suppliers 3 3 Your license to use the Software shall commence upon the execution of this Softwa
92. fore current date fo Days after current date fo Modalities Iv px Iv px M Io Other cR xc Lc Scheduled Station I Use this AE Title D Advanced Columns Colors Hide following worklist items Stored older than curenta CY Copy Scheduled Procedure Step Description To Study Description Copy Requested Procedure Description To Study Description Study date time use current date and time e om The DICOM Modality Worklist Server allows information about patients to be obtained from the Hospital Information System The software supports the Modality Worklist Service as a Service Class User The Modality Worklist Service Class Provider is a program which purpose is to provide information to the Modality Worklist Service Class User Worklist Page allows a connection to the Modality Worklist Service Class Provider SCP to be configured Instrumentarium Dental 95 5 Configuring DICOM 96 5 3 1 WorkList SCP Box AE Title This option specifies the Application Entity Title for the SCP application The AE Title is a characters string with a maximum length of 16 characters The AE Title is a DICOM name for a DICOM Modality Worklist Service Class Provider SCP which can receive DICOM queries from the software Host Name Is the remote host name or its IP Address For example 10 1 1 0 Port Is the TCP port on which the remote DICOM system listens for connections The default DICOM port number is 104 O
93. formation CLINIVIEW can be used for a trial period of up to 30 days after installation When the trial period has expired CLINIVIEW must be licensed To activate the CLINIVIEW license you must use the activation key an alphanumeric code that is printed on a sticker attached to the CLINIVIEW software CD case Save the activation key in a safe place The CLINIVIEW license activation requires an Internet connection If the computer in which CLINIVIEW is to be installed is not connected to the Internet select the offline activation method and use any computer that is connected to the Internet to activate the license If the license activation cannot be completed after installing CLINIVIEW activate the trial period by selecting Start Trial Now from License Activation Wizard which is shown when starting CLINIVIEW CLINIVIEW can now be used for up to 30 days The offline license activation process can now be completed later at a different location where you have access to the Internet Note that the license activation response file that you will receive must be sent back to the site where CLINIVIEW was installed to complete the offline license activation process In case capturing workstation also acts as Database workstation and is installed with Licensing server and database sharing activate the standalone CLINIVIEW license first and then the CLINIVIEW network license Note that the standalone lic
94. g DICOM A message is constructed from attributes having values and each attribute is identified by a tag An attribute is a unit of data e g Patient s Name Patient 10 A tag is a 4 byte number identifying an attribute e g 00100010H for Patient s Name A tag is usually written as an ordered pair of two byte numbers The first two bytes are sometimes called a group number and the last two bytes are called an element number e g 0010 0010 0038 001C This terminology is partly a remnant of the DICOM Standard DICOM specifies Information Object Definitions IOD s as being composed of modules Each module contains attributes Attributes can be required optional or only required under certain conditions conditional attributes Conditional attributes are always specified along with a condition Storage list Edit button To change information of one of the destinations attributes that is already in the storage attributes list perform the following steps 1 Select the attribute to be changed the line is selected 2 Click Edit The Modify Tag window appears 3 Enter the new information and click OK The changes appear in the storage attributes list Storage list Delete Button Allows an attribute to be deleted from the storage attributes list To do this 1 Select the attribute to be deleted the line is selected 2 Click Delete 3 Adelete confirmation message appears Click OK to d
95. ging DICC devices 4 Click Update Driver Computer Management el File Action View Window Help eo fH e662 ATRA Computer Management Local B EETEST EA System Tools Y Computer a Event Viewer See Disk drives Fa Shared Folders Display adapters Local Users and Groups JA DVD CD ROM drives Floppy disk controllers Device Manager a Floppy disk drives 1 Performance Logs and Alerts a z e Storage Sy IDE ATAJATAPI controllers Removable Storage 3 Instrumentarium Imaging DICC devices j Disk Defragmenter B Disk Management Keyboa pens Driver Services and Applications j Mice an Disable 4 59 Monitor Uninstall HB Metwor Ports C Sound Properties See Storage System devices Universal Serial Bus controllers Scan for hardware changes Launches the Hardware Update Wizard For the selected device 5 Select Install from a list Click Next Hardware Update Wizard Welcome to the Hardware Update Wizard This wizard helps you install software for Il Serial link PCI driver O If your hardware came with an installation CD or floppy disk insert it now What do you want the wizard to do O Install the software automatically Recommended Install from a list or specific location Advanced Click Next to continue Instrumentarium Dental 81 4 Driver installation 6 Select Don t search Click Next Hardware Update Wizard Plea
96. icense to use these C No DICOM components features V DICOM Worklist e INSTRUMENTARIUM IV DICOM Print IV DICOM Storage IV DICOM Query Retrieve Installshield 7 Review the license agreements and click Yes to accept the license terms and continue with the installation License agreements Do you accept the following license agreements CLINIVIEW software license View license Microsoft DirectX runtime license 2 INSTRUMENTARIUM Installshield 209804 rev 2 Instrumentarium Dental 49 2 Software installation 8 Review installation settings and click Next to start in stallation process Start Copying Files Review settings before copying files Setup is ready to install CLINIVIEW to this computer with the following settings Current Settings Features selected Client Dicom components Installed devices Destination folder J INSTRUMENTARIUM C Program Files CLINIVIEW Installshield 9 Click Yes if you wish to view Readme Question e Do you want to view Readme 10 Select if you wish to start the software automatically af ter the workstation is restarted restart is necessary when DICOM features are installed Click Finish to restart computer InstallShield Wizard Complete Setup has finished installing CLINIVIEW 10 2 2 on your computer Before you can use the program you must restart your computer INSTRUMENTARIUM C
97. ill be connected to the software A WARNING Before you start the upgrade back up the database and images Note Install latest OP100 D OP200 D PCI card drivers af ter upgrading software Note Upgrading will create Windows Firewall settings au tomatically 7 1 Upgrade from CLINIVIEW 7 1 0 or newer 1 Insert the software DVD into the DVD ROM drive 2 If the InstallShield Wizard does not appear after a few moments browse to the software DVD and double click CLINIVIEWSetup exe to begin installation Note If the User Account Control window appears you must allow changes to continue installation 3 Click Next to begin CLINIVIEW upgrade CUNIVIEW 10 2 2 InstallShield Wizar Welcome to the InstallShield Wizard for CLINIVIEW 10 2 2 4 INSTRUMENTARIUM The InstallShield Wizard will upgrade the previous release of CLINIVIEW into version 10 2 2 4 on m your computer To continue click Next Baci Nei Cancel 209804 rev 2 Instrumentarium Dental 137 7 Upgrading the software 4 Review the license notification and click Yes to contin ue upgrading ER Warning You are upgrading an older version of the software WE Please note this version of the software requires a new LICENSE ACTIVATION KEY Previously issued license keys are not compatible with this software version Please ensure that you have a new license activation key before upgrading If you do not have a new license activa
98. inly occur when the network fails or when read ing in or writing DICOM messages Warning level This level logs warning messages Info level This level logs informational messages T1 level not used T2 level This level logs the entire contents of messages sent or received over the network T3 level This level logs information related to association negotiation T4 level This level logs information when incoming associ ations are being rejected T5level This level logs information when a message is val idated T6 level This level logs the contents of the Merge tool kit configuration T7 level This level logs the contents of a the command ele ments group 0 for received and sent messages T8 level This level logs warning messages related to streaming in or out messages and files T9level This level logs information about PDUs sent or re ceived Blank fill log file If this feature is selected the log file size is to be ex panded to the maximum possible size Backup old log files If this feature is selected old log files are backed up A Historical log files To select the number of historical log files saved 122 Instrumentarium Dental 209804 rev 2 5 Configuring DICOM The Performance Page allows various parameters to be changed to improve performance x Log Files Performance Priority Below normal Y PDU max length m Timeouts Asso
99. installed Press Register now to give feedback and to launch CLINIVIEW software Pressing No thanks launches CLINIVIEW software Online activation Activation successful Enter activation key P123 1234 1234 1234 Activate License has now been successfully activated lt Back mr Cancel Instrumentarium Dental 209804 rev 2 3 Licensing CLINIVIEW Offline connection The computer is not connected to the Internet 1 When the CLINIVIEW software is opened for the first time a license activation request appears Select Activate workstation node locked license T anew arera J INSTRUMENTARIUM Welcome to License Activation Wizard Start trial or activate your license L Start trial now J Begin using the product right away You may use the product up to 30 days without restrictions Aetate woristation inoderocked icense Enter activation key to activate the product on this computer W Use network license aJ Network licenses can be used from any workstation Network licenses are returned automatically to local license server after closing the software 2 The Select activation method window appears Select Offline activation and then press Next Select activation method Select online activation if this computer is connected to the Internet Online activation Select this method if this computer is connected to the Internet Offline activ
100. ion Note If the User Account Control window appears you must allow changes to continue installation 3 Select CLINIVIEW Advanced installation Select Features Select the feature you want to install Please select the feature that you want to install CLINIVIEW Quick Install Standalone or small network server No Volumetric Tomography or DICOM features CLINIVIEW Network Client Client without database No Volumetric Tomography or DICOM features CLINIVIEW Advanced Standalone or small network server Includes Volumetric Tomography and DICOM features INSTRUMENTARIUM CLINIVIEW Manuals Installshield 4 Select Install CLINIVIEW database this option in stalls database engine and CLINIVIEW database Select database option Database options Description Install CLINIVIEW software patient and x ray image database C Search existing MS SQL Servers C CLINIVIEW software only 2 INSTRUMENTARIUM Installshield Instrumentarium Dental 53 2 Software installation 5 Choose Destination folder for the database engine Click Next to accept default and continue or click Browse to change the location Note The destination folder for the database engine contains only the database files not images Image data location will be selected in the next step Choose Destination Location Select folder where setup will install files Please enter the path for database engine i
101. ion 13 Review installation settings and click Next to start in stallation process Start Copying Files Review settings before copying files Setup is ready to install CLINIVIEW to this computer with the following settings Current Settings Database Licensing Server Client VT Reconstruction server Dicom components INSTRUMENTARIUM Installed devices Destination folder C Program Files x86 CLINIVIEW Database media folder CACVDATAS Database tables folder C Program Files x86 CLINIVIEWD atabase Installshield 15 Select if you wish to start the software automatically af ter the workstation is restarted restart is necessary when DICOM features are installed Click Finish to end the installation InstallShield Wizard Complete Setup has finished installing CLINIVIEW 10 2 2 on your computer Before you can use the program you must restart your computer INSTRUMENTARIUM C No will restart my computer later Remove any disks from their drives and then click Finish to complete setup After the reboot log in with administrator privileges to finish the installation IV Launch CLINIVIEW after finishing Installshield B Finish 58 Instrumentarium Dental 209804 rev 2 209804 rev 2 2 Software installation 16 Select software default language Note Software language can be changed at any time within the software from the Tools menu Languages F j
102. ion manage users schedule backups manage trash and logs 10 1 Login The CLINIVIEW Manager can be launched from Start gt Programs gt CLINIVIEW gt Tools gt Manager Most of the features in CLINIVIEW Manager are password protected to prevent unauthorized usage H Cliniview Manager login x User name Password Cancel Enter the user name password and click OK Default user name is admin and password is admin Cliniview Manager xi File Help CliniView Manager Archive Images Database Q Create Remove archived User management Restore Settings Database backup licence location Trash Exit Report logs INSTRUMENTARIUM 209804 rev 2 Instrumentarium Dental 151 10 CLINIVIEW Manager 152 10 2 Archiving To release hard disk storage space on the server the unused images can be copied or moved to an archive media The information and scout images of these images remain in the database allowing easy retrieval whenever it becomes necessary to view any of the archived images 10 2 1 Create archive 1 To archive images select Create from CLINIVIEW Manager dialog x Specify media and temporary archival folder Media type CD ROM 650 Temporary archival folder DA Volume label CV 2009 Capacity 20677 MB Maximum size of media Ej MB uper est Vb Free 9932 MB m Search for non active patients
103. istrator 2 Enter the administrator password in the command line admin by default 3 The software database file is backed up pidbms de dat in the backup directory e g CVDATA Backup 4 Make a backup of the image directory e g C CVDATA INCLUDE ALL CONTENTS 5 Mark the backup media with the current date and store it in a safe place Instrumentarium Dental 209804 rev 2 209804 rev 2 6 Software database 6 2 2 Restoring the software database from the backup Note f you use 32 bit SQL Server in 64 bit Windows do the following modification in ImportDB bat before execut ing it Replace instances of Program Files with Program Files x86 in OSQLEXE and SQLCMD definitions Note This procedure overwrites any existing patient data stored in the software database Note This procedure does not restore users and creates default users Use CLINIVIEW Manager to recreate us ers 1 Make sure that all users have been logged off the soft ware database restore does not succeed if the data base is in use e g make sure that PaloDEx 3D Reconstruction Service and CliniView Database Backup Service are not running 2 Restore the image directory e g C CVDATA from the backup INCLUDE ALL CONTENTS 3 Run ImportDB bat located in the Tools folder In Windows 7 run file in command line opened with Run as administrator 4 Enter the administrator password in the command line admin by default 5 The d
104. ivation method Select online activation if this computer is connected to the Internet Online activation Select this method if this computer is connected to the Internet Offline activation Select this method if this computer is not connected to the Internet lt Back next gt Cancel 3 The Registration page appears Enter all the registration information It is important to enter the license owner contact information correctly Mandatory fields are marked with an asterisk When you have entered all the required information into the Registration page click OK E co INSTRUMENTARIUM Registration Registration is required for activation Please provide license owner information below Accu information helps us to deliver timely after sales support Company Information 209804 rev 2 Instrumentarium Dental 63 3 Licensing CLINIVIEW 64 The Online activation window appears Enter the soft ware activation key that is printed on the sticker at tached to the CLINIVIEW software CD case into the Enter activation key field Click Activate CLINIVIEW connects to the license server to activate the license Online activation Activate the product using Internet connection Enter activation key Press Next when the license has been successfully ac tivated The following window asks to submit feedback on the products which were purchased and
105. k Insert the manufacturer s installation disk and then DK P make sure that the correct drive is selected below Copy manufacturer s files from G Cliniview Drivers PCIDrv Instrumentarium Dental 79 4 Driver installation 80 7 Click Next Found New Hardware Wizard Select the device driver you want to install for this hardware p Select the manufacturer and model of your hardware device and then click Next If you have a disk that contains the driver you want to install click Have Disk v Show compatible hardware Model Serial Link PCI Device amp This driver is not digitally signed Have Disk Tell me why driver signing is important lt Back Next gt Cancel 8 The PCI driver is now installed Proceed to software in stallation If the driver installation fails proceed to the chapter Uninstalling the driver Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing the software for 339 Serial Link PCI Device Click Finish to close the wizard Instrumentarium Dental 209804 rev 2 209804 rev 2 4 Driver installation 4 3 1 PCI driver update Software requires PCI driver 2 3 If an older PCI driver is installed it must be upgraded Update the PCI driver as follows 1 Right click My Computer and choose Manager 2 Choose Device Manager 3 Right click II Serial link PCI driver Instrumentarium Ima
106. l be moved manually seve Lees 2 Create a new data directory and share it if network in stallation 3 Copy all files and subdirectories from main directory e g CVDATA to the new data directory 4 Browse the new data directory and click Save Note Be sure that the software is not used when changing the data directory 10 3 1 3 Report Exposure statistics 1 To create an exposure statistics report select Report from CLINIVIEW Manager main view 2 Enterthe report parameters and click Generate to cre ate a report 2 Image Report Images between i 1 2006 and 27 1 2006 v Destination file name C Program Files CliniViewST ools Manager Report hl Open Report when ready Internet Explorer used Settings Generate Close Instrumentarium Dental 209804 rev 2 10 CLINIVIEW Manager Viewing report Open htm file e g Report htm with Internet Explorer E C Program Files CliniView Tools Manager Report htm Microsoft Internet Explorer DER Fie Edit View Favorites Tools Help a x a P Search she Favorites media A 2 X LJ Fel Address E c Program Files Cliniview Tools Manager F Y EJ co Links SupportCentral xi Exposure Statistics Clini View 2006 01 30 Pan Total 1 Ceph Lat Total 1 Date Range 2006 01 01 2006 01 30 Image 1 2006 01 27 Ceph Lat Farmer Ted 20 12 6 85 1 34 26 2 2006 01 27 Pan Farmer Ted 13 8 66 3 44
107. llation To perform the software DICOM configuration you need the following information this information is normally provided by the local network administrator m Network configuration information for the software workstation Port numbers for DICOM configurations IP addresses AE titles for the software entities AE titles Port numbers and IP addresses for the needed DICOM devices Storage server Storage Commitment Printer Worklist Query retrieve The IP addresses port numbers and AE titles for all connections can be obtained from the hospital s ADP personnel amp suppliers Note Access to the DICOM configuration settings is al lowed to administrator users only Either run the software explicitly with administrator rights or in Windows XP use an Windows user account that has administrator rights The DICOM configuration window The tabbed pages The DICOM configuration window includes a tabbed set up property page for each of the features selected when the DICOM addition was installed If all four features were selected there are six tabbed set up property pages These are General Storage Print Worklist Query Retrieve Storage SCP SOP Classes Instrumentarium Dental 91 5 Configuring DICOM 92 The main configuration buttons After making configuration changes click Apply or OK at the bottom of the DICOM configuration window to accept Gees ee the changes m Apply button IDICOM
108. ment Studio SQL Server Management Studio should be run as an adminis trator user In Object Explorer select the server and then right click for properties On the security page under Server Authentication select SQL Server and Windows Authentication mode and click OK Then click OK on the dialog stating the need to re start SQL Server To restart the server select the server and then right click and select Restart 3 SQL Server Browser service must be started automat ically This can be configured during SQL Server instal lation or using SQL Server Configuration Manager How to configure SQL Server Browser start parameters using SQL Server Configuration Manager Start SQL Server Configuration Manager as ad ministrator Click SQL Server Services in the left pane Double click SQL Server Browser service in the right pane Click the Service tab change Start Mode parame ter to Automatic and click Apply Go to Log on Tab and click Restart button Click OK to exit Instrumentarium Dental 209804 rev 2 2 Software installation 4 TCP IP protocol must be enabled in the SQL Server Database Engine To configure TCP IP protocol using SQL Server Configuration Manager after patient database installation e Start SQL Server Configuration Manager as ad ministrator e Click SQL Server Network Configuration 32 bit in the left pane e Double click TCP IP in the right pane Change En abled to Yes click Ap
109. mentarium Dental 33 2 Software installation 10 Review the installation settings and click Next to start installation process Start Copying Files Review settings before copying files Setup is ready to install CLINIVIEW to this computer with the following settings Current Settings Features selected Database Licensing Server Client Dicom components Destination folder C Program Files x86 CliniView 2 INSTRUMENTARIUM Database media folder CACVDATAN Database tables folder C Program Files x86 Cliniview D atabase Installshield 11 View software release info Readme InstallShield Wizard Complete Setup has finished installing CLINIVIEW 10 2 2 on your computer e INSTRUMENTARIUM Installshield Cancel 12 Click Finish to end installation process Start the Li cense Manager and activate network licenses See Chapter 3 2 1 Licensing CLINIVIEW network for more information 34 Instrumentarium Dental 209804 rev 2 209804 rev 2 2 Software installation 13 Optional If the local network does not support DNS or WINS you must change File Server to use the server s IP address in place of its host name To do this open CLINIVIEW Manager Click File Server Config and enter the user name and password when prompted Enter the IP address of the server and click Save Close CLINIVIEW Manager CLINIVIEVV Manager Archive Images Database File Server Configuration Q Create
110. mic OP300 Cephalometric OP300 3D m 11 12 13 14 15 If the selected device requires a gain file the software will prompt to open the GainInstaller tool Browse to the location of the gain file s and install them using the Gainlnstaller tool Note Only certain devices require a gain file Software is ready for use A patient named Calibration Patient will be created and opened This patient can be used to store all calibration images for the installed de vice s Test installation by acquiring an image according to de vice user manual or quick guide Configure the desired user settings for the software See user manual for more details If the software with be used with a Cone Beam 3D de vice install a 3D visualization software Launch options for the 3D visualization software can be configured on the Tools menu Cone Beam 3D Settings Instrumentarium Dental 209804 rev 2 2 Software installation 16 Repeat the software installation for each network mo dality workstation needed 2 3 5 Network modality workstation with DICOM 1 Insert software DVD into DVD ROM drive 2 If the InstallShield Wizard does not appear after a few moments browse to the software DVD and double click CLINIVIEWSetup exe to begin installation Note If the User Account Control window appears you must allow changes to continue installation 3 Select CLINIVIEW Advanced installation Select Features
111. mitment Failed Reports can still be received and they are processed even after this timeout has expired Delay between storage and commitment The time period that Storage Commitment SCU waits after Storage before sending the Storage Commitment request Instrumentarium Dental 109 5 Configuring DICOM 5 5 Print configuration Open this page for the first time after installation and see two empty lists 1 The Print Destination List 2 The Print Attributes List DICOM settings x General Worklist Storage Print Storage SCP AE Title Port Number DICOM PRINTER 10 0 03 Verify Set LUT Advanced Add new Edi Delete Hg e _ Type Devi La 20100010 Image Display Format Basic Film Box Replace if empty 20100030 Annotation Display Format ID Basic Film Box Replace if empty 20100040 Film Orientation Basic Film Box Replace if empty PORTRAIT 20100050 Film Size ID Basic Film Box Replace if empty 20100060 Magnification Type Basic Film Box Replace if empty CUBIC 20100080 Smoothing Type Basic Film Box Replace if empty 1 20100100 Border Density Basic Film Box Replace if empty WHITE 20100110 Empty Image Density Basic Film Box Replace if empty 20100120 Min Density Basic Film Box Replace if empty 20100130 Max Density Basic Film Box Replace if empty 300 20100140 Trim Basic Film Box Replace if empty zl Add new zl Edit Delete Print Destination List To the Print Destination List add DICO
112. mport and export image files Supported file formats are D32 JPG JPG2000 TIF BMP and PNG D32 is Instrumentarium s proprietary own file format Images can be saved in the database in PNG 16 bit or JPG formats 12 bit The software can be used in a network environment If the software is installed in several computers the patient and image database can be shared and used from different workstations We recommend to read this manual before installing and using the software Manufacturer s liability As a manufacturer we can only assume liability for safe and reliable operation of this software when the PC software is installed and used according to the software installation and user manuals Note Safe and reliable usage of the product requires that the user has read and understood the instructions and re strictions given in the manual Instrumentarium Dental 209804 rev 2 1 3 Abbreviations 1 Introduction PC Personal computer HD Hard disk Hz Hertz cycles per second MHz Megahertz millions of cycles per second CPU Central processing unit comput er RAM Random access memory MB Megabytes GB Gigabytes CCD Charge coupled device DVD RW Digital Versatile Disc re writa ble PCI Peripheral Component Intercon nect DAT Digital audio tape MOD Magneto optical drive USB Universal Serial Bus VfW Video for Windows a video for mat supported by the soft
113. ng modes select either or both modes Refer to the operating manual supplied with the DICOM printer for more information Click OK after entering all the required information A print page appears which indicates that a new printer has been successfully added to the list The top list shows the configuration information that has been entered The bottom list shows all the printer s attributes and their characteristics Tag number Name Module Type and default value Repeat the above procedure each time to add a DICOM printer Print page Edit button Change the information in the printer list 1 Select the printer to be edited 2 Click Edit 3 The Edit Printer Properties window appears Enter new printer information 4 Click OK to accept the changes The destination infor mation in the printer destination window is updated Print page Delete button Delete a printer from the print list 1 Select the printer to be deleted 2 Click Delete 3 A delete confirmation message appears Click Yes to delete the printer Instrumentarium Dental 209804 rev 2 209804 rev 2 Print page Advanced button The Log Files and Performance 5 Configuring DICOM pages provide parameters for adjusting the low level settings of the DICOM network services There are similar settings for all the DICOM network services See chapter 5 8 Log File and Performance Settings Log Files Performance Error L
114. nish to view the software release info Readme and start the software InstallShield Wizard Complete Setup has finished installing CLINIVIEW 10 2 2 on your computer IV View Readme INSTRUMENTARIUM Installshield lt Back Finish Cancel Note Software installation will take several minutes depending on the computer 209804 rev 2 Instrumentarium Dental 19 2 Software installation 20 Select default language for the software and click OK to continue Note Software language can be changed at any time within the software from the Tools menu Languages 7 Language selection a Select language To activate the license select Activate Workstation li cense See Chapter 3 2 Licensing CLINIVIEW soft ware standalone The installed devices window will be displayed Select the devices to be connected to this workstation and click OK to enable the devices OP100D DC100D Cancel OC200D OP200DSmartNav OC200DSmartNav SIGMA M small SIGMA M large SNAPSHOT sensor EXPRESS OP30 OP300 Panoramic OP300 Cephalometric OP300 3D m 10 11 12 13 If the selected device requires a gain file the software will prompt to open the GainInstaller tool Browse to the location of the gain file s and install them using the GainInstaller tool Note Only certain devices require a gain file Software is ready for use and a patient named Calibra tion Patient will be cr
115. nstance This folder is where the database tables are saved 2 INSTRUMENTARIUM Installshield 6 Choose the destination for image data Click Next to continue or click Browse to change the location Choose Destination Location Select folder where setup will install files Please enter the path for database media files This folder is where the patient images are saved 2 INSTRUMENTARIUM InstallShield 54 Instrumentarium Dental 209804 rev 2 2 Software installation 7 Select No do not want to install License Server Click Next to continue Select License Server License Server Description C Yes want to install License Server This is License Server installation License Server is installed to a server No do not want to install License Server 2 INSTRUMENTARIUM Installshield 8 Select Yes want to install CLINIVIEW software then click Next Select Workstation Software option Workstation Software options r Description 4 This will install CLINIVIEW software 7 No do not want to install CLINIVIEW software 2 INSTRUMENTARIUM Program installation folder C Program Files 85 NCLINIVIEW Installshield 209804 rev 2 Instrumentarium Dental 55 56 2 Software installation 9 Select if DICOM features will be installed and then click Next Select DICOM features Sele
116. ntal 163 10 CLINIVIEW Manager 164 10 5 10 6 File Server Configuration In a network configuration as a default computer name is used instead of IP address In case of misconfigured DNS server or absence of a local DNS server it is recommended to use the IP address This can be manually done using the file server configuration by specifying the correct IP address instead of the computer name The default port for File Server is 898 In case the default port is being used by some other application default port can then be changed using File Server configuration Select File Server Configuration from the Manager dialog File File Server Configuration CliniView Manager Logged out 28 File Help CliniView Manager Archive mage Database File Server Configuration v Q Create IE User management IP or computer name Restore Port IF Database backup Use defaults Save i Close licence Trash Exit Report logs INSTRUMENTARIUM L Note The File server IP must not be configured to a differ ent computer than where the Database is running License The License button opens the license manager window See the chapter 3 Licensing Instrumentarium Dental 209804 rev 2 11 Using practice management interface 11 Using practice management interface Note If patient data is tranferred in to the software by other software this software must conform to applicabl
117. o Volumetric Tomography or DICOM features CLINIVIEW Advanced INSTRUMENTARIUM Standalone or small network server Includes Volumetric Tomography and DICOM features fo D CLINIVIEW Manuals Installshield Cancel 209804 rev 2 Instrumentarium Dental 21 2 Software installation 4 Review the license agreements and click Yes to accept the license terms and continue with the installation License agreements Do you accept the following license agreements CLINIVIEW software license i Viewlicense Microsoft Direct runtime license View license Microsoft SQL Server Express license Viewlicense 2 INSTRUMENTARIUM Installshield 5 Review the installation settings and click Next to start installation process Start Copying Files Review settings before copying files Setup is ready to install CLINIVIEW to this computer with the following settings Current Settings Features selected Database Licensing Server Client Installed devices Destination folder C Program Files x86 CLINIVIEW INSTRUMENTARIUM Database media folder CNCVDATAN Database tables folder C Program Files x86 CLINIVIE WD atabase Installshield Note License Server will always be installed when using Quick installation 22 Instrumentarium Dental 209804 rev 2 209804 rev 2 2 Software installation 6 Wait until installation is completed and click Next to view the software release info R
118. og File Filename Maximum size lines 500 Eu Browse Activity Log File Filename C Documents and Settings All UserslA Maximum size 1000 Id Use error log file Browse r r Message Log File Filename C Documents and Settings All Users 4 Maximum size lines 100000 Line length Log Messages Levels Blank fill log file v Error level Backup old log File Iv Warning level viTnfo level z Historical log files Browse cod r r 4 Print page Verify button Verify DICOM printer connection Instrumentarium Dental 113 5 Configuring DICOM 5 5 2 Print page Attributes List buttons With the attribute list buttons you can edit the printer default settings DICOM settings x General Worklist Storage Print Query Retieve Storage scp AE Title _ Le ades Po Port Number DICOM PRINTER RINT SCP 10 0 03 20100010 Image Display Format Basic Film Box umm if empty 20100030 Annotation Display Format ID Basic Film Box Replace if empty 20100040 Film Orientation Basic Film Box Replace if empty PORTRAIT 20100050 Film Size ID Basic Film Box Replace if empty 20100060 Magnification Type Basic Film Box Replace if empty CUBIC 20100080 Smoothing Type Basic Film Box Replace if empty 1 20100100 Border Density Basic Film Box Replace if empty WHITE 20100110 Empty Image Density Basic Film Box Replace if empty 20100120 Min Density Basic Film Box Replace if
119. ognize the cor rect License Manager tool from the large red text LICENSE SERVER on the tool window r n f License Manager INSTRUMENTARIUM Acquire license sf Activate license LICENSE SERVER Activated licenses Product Version License type Status Activation key Expiration CLINIVIEW 10 20 User 10 2 Publisher Activation ENABLED PERMANENT G Refresh 2 Settings O Show log About Exit Instrumentarium Dental 71 3 Licensing CLINIVIEW 3 2 1 2 Configuring workstations to use CLINIVIEW network license F G canoe teasa INSTRUMENTARIUM Welcome to License Activation Wizard Start trial or activate your license Start trial now Begin using the product right away You may use the product up to 30 days without restrictions Activate workstation node locked license Enter activation key to activate the product on this computer Network licenses can be used from any workstation Network licenses are returned automatically to local license server after closing the software Configure CLINIVIEW workstations to use network license by selecting the option Use network license from License activation wizard Enter the Licensing server hostname or IP address to the next screen gt CUNIMEW License J INSTRUMENTARIUM Use local license server Enter local license server connection settings Local license server address
120. or IP address 127 0 01 Port Number 104 r Network Parameters Network status OK Association status Normal Completion Remote Implementation Class UID 2 16 840 1 25 1 Remote Implementation Version MergeCOM3 321 Service Name Roe Syntax Service UID Syntax uo STANDARD_CR SCP EXPLICIT LITTLE EN 1 2 840 10008 5 1 2 840 10008 STANDARD CT SCP EXPLICIT LITTLE EN 1 2 840 10008 5 1 2 840 10008 STANDARD CURVE SCP EXPLICIT LITTLE EN 1 2 840 10008 5 1 2 840 10008 STANDARD DX PRESENT SCP EXPLICIT LITTLE EN 1 2 840 10008 5 1 2 840 10008 STANDARD DX PROCESS SCP EXPLICIT LITTLE EN 1 2 840 10008 5 1 2 840 10008 STANDARD ECHO SCP EXPLICIT LITTLE EN 1 2 840 10008 1 1 1 2 840 10008 STANDARD HARDCOPY C SCP EXPLICIT LITTLE EN 1 2 840 10008 5 1 2 840 10008 STANDARD HARDCOPY G SCP EXPLICIT LITTLE EN 1 2 840 10008 5 1 2 840 10008 ETAMDAND TA NNESEMT cen EVM TOTT ITTTIC CM 12 oan 10nno c 12 oan Print Preview Save As The DICOM parameters are from the destination The Network Parameters are parameters that provide information about the status of the communication with that remote entity If communication fails the Network status is Failure and the Association status explains the cause of the failure for example Failed to connect to remote host NA appears in both the Remote Implementation Class UID and Remote Implementation v
121. ords for each user Select User management from CLINIVIEW Manager dialog gf user Management x Users must enter a user name and password to use Cliniview M Users for Cliniview PIDBDefault Default Administrator Add Remove Properties M Password for admin To change the password the admin click set password Set Password Close Administrator category means that the user has rights to both the software and CLINIVIEW Manager Users in default category are entitled to start the software program only RRRR Mark the upper left corner to activate the user management function Add and remove users To add a user click Add 209804 rev 2 Instrumentarium Dental 159 10 CLINIVIEW Manager 160 Select the name of the user from the list or click Add to create a new user luser management 04 Users must enter a user name and password to use CliniView UliniView users User Name admin Administrator Add Update Set Password Close Enter the information for the new user and click OK Note The maximum length of the user name is 36 charac ters and the maximum length of the password is 64 charac ters User names and passwords must be composed of printable ASCII characters The following characters are reserved and cannot be used in user names or passwords tab space 1 To change
122. patient named Calibration Patient will be created and opened This patient can be used to store all calibration images for the installed de vice s Test upgrade by acquiring an image Instrumentarium Dental 209804 rev 2 209804 rev 2 7 Upgrading the software 7 2 Upgrade from CLINIVIEW 7 0 2 or older Upgrading directly from CLINIVIEW 7 0 2 or older is not supported When upgrading from CLINIVIEW 7 0 2 first upgrade to CLINIVIEW 7 1 using the instructions provided in CLINIVIEW 7 1 and then follow the instructions in the previous chapter Instrumentarium Dental 141 7 Upgrading the software 142 Instrumentarium Dental 209804 rev 2 8 Adding features It is possible to add features or modalities at any time after the installation e g VT DICOM 8 1 Adding devices Device support in the software is installed during the software installation You can add a new device at any time after the installation Add devices in the software by selecting Tools Installed devices IntraCam OP200DSmartNav DC200DSmartNav Sigma M small Sigma M large Snapshot sensor Express OP300 Panoramic OP300 Cephalometric OP300 3D Note IntraCam is shown in the list only when Intra Camera is installed to the workstation After closing the dialog the device specific image capturing button will be visible in the software main window Configure the device according to device installation manual or Quick guide
123. ply e Click OK to exit e Click SQL Server Service in the left pane and lo cate SQL Server database name in the right pane Right click this service and select Restart e Close the SQL Server Configuration Manager Existing database installation EDBI 1 Insert software DVD into DVD ROM drive 2 If the InstallShield Wizard does not appear after a few moments browse to the software DVD and double click CLINIVIEW Setup exe to begin installation Note If the User Account Control window appears you must allow changes to continue installation 3 Select CLINIVIEW Advanced installation Select Features Select the feature you want to install Please select the feature that you want to install CLINIVIEW Quick Install Standalone or small network server o Volumetric Tomography or DICOM features CLINIVIEW Network Client Client without database No Volumetric Tomography or DICOM features CLINIVIEW Advanced lone or small network server INSTRUMENTARIUM VIEW Manuals 209804 rev 2 Instrumentarium Dental 37 2 Software installation 4 Select Search existing MS SQL Servers Select database option Database options Description Install CLINIVIEW database Enhanced Database Installer amp dvanced not recommended This will search your computer for CLINIVIEW compatible database servers Patient and x ray image CLINIVIEW software only database is created for CLINIVIEW 2
124. r installation 4 5 2 Video Source dialog Open the Video source dialog by clicking Source Source x Stream Format Video Format gt r Compression Video Standard PAL B Frame Rate 25 000 Ej Frame Interval E so S m Flip Horizontal P Frame Interval aa E Color Space Compression RGB 24 Dutput Size Quality 384 x 288 default Y E Cancel Apply Select the requested dimensions for the camera window from the Output Size list Select the requested color setting from the Color Space list It is recommended to use 24 bit RGB These alternatives vary according to camera manufacturer and country 209804 rev 2 Instrumentarium Dental 87 88 4 Driver installation 4 5 3 Video Input dialog T Click Input to open the window xi Crossbar r Input m Output fo Video SVideo In fo Video Decoder Out Current Input D Video SVideo In Related Pin Related Pin B Audio Line In 1 Audio Decoder Out Link Related Streams 4 Cancel Apply Select the used input video connector from the Input list S video is recommended Instrumentarium Dental 209804 rev 2 4 Driver installation 4 5 4 Link the software to Intra camera event If Intra Camera supports events link the software to the Intra camera event e g Snapshot Button Pressed event When the Intra camera s snapshot button is pressed the software retrieves
125. ram starts its Maintenance mode Click the Remove button to uninstall the software Software uninstallation leaves folders on the hard drive and saves the database and images Uninstallation is for removing the software only Uninstallation does not remove any device drivers that may be installedSigma USB or Repeat the software unistallation as needed for all computers Modality workstation viewing workstation server having any software components A CAUTION When software and database is uninstalled access to images and patient data will be lost until the software is reinstalled and the data restore procedure has been completed Please refer to chapter 6 3 for details After restore images and patient data will be accessible again Note If uninstallation shows a warning Database could not be locked close the software from all client computers and try again If all clients are closed and the error still oc curs restart the computer and retry uninstallation Note Only the CLINIVIEW is removed Other software components that may be installed during CLINIVIEW jn stallation such as IAM and License Server can be unin stalled if no longer needed Instrumentarium Dental 149 9 Uninstalling 150 Instrumentarium Dental 209804 rev 2 10 CLINIVIEW Manager 10 CLINIVIEW Manager The CLINIVIEW Manager is used to archive images restore archives alter image saving format define data directory images locat
126. re The license key of the software is entered either during the software client installation or in CLINIVIEW Manager after the installation 5 1 2 Retired Command Elements Controls are provided to select how the software uses the command elements that have been retired from the DICOM standard 3 0 It is recommended to leave these controls empty SOP Class configuration The software allows to configure which SOP Class is used to correspond the image types of the software x General SOP Classes Worklist Storage Print Query Retrieve Storage SCP cephalo Digital X Ray Image Storage For Processing 0X Ens TL Pnotogrechic Image Storage VT projection Digital X Ray Image Storage For Processing 0X xl VT reconstruction CTimageStrage O e CB3D Enhenced CT Image Storage RR CB3D scout Digital X Ray Image Storage For Processing DX x Cancel Apply Instrumentarium Dental 93 5 Configuring DICOM Panoramic images Digital X Ray Image For Processing PX default Digital X Ray Image For Presentation PX Digital X Ray Image For Processing DX Digital X Ray Image For Presentation DX Computed Radiography Image Storage Cephalometric images Digital X Ray Image For Processing DX default Digital X Ray Image For Processing DX Computed Radiography Image Storage Intra images Digital X Ray Image For Processing DX default Digital X Ray Image For Processing DX
127. re License and shall thereafter remain in effect unless you fail to comply with the terms and conditions of this Software License in cluding any amendments thereto Upon termination by Licensor or its suppliers of this Software License you shall within two 2 business days thereafter certify to Licensor that in accordance with instructions from Li censor or its suppliers all copies of the Software have been either destroyed or returned to Licensor whether same is in tangible or intangible form and you shall fur Instrumentarium Dental 209804 rev 2 209804 rev 2 12 Software license ther certify that all use thereof is and shall remain termi nated 3 4 You agree to comply with all applicable export and re export restrictions and regulations including the ones imposed by the government of the United States or of the country to which the Software is shipped to you You shall not commit any act or omission which will result in a breach of any such export requirements 3 5 Should you receive any copy of the Software to up grade a previous version of such Software such up graded version of the Software shall be the only version you are entitled to use unless otherwise agreed and unless expressly otherwise permitted by Licensor you shall destroy or erase all program material and related documentation including all copies and modifications relating to the previous Software Copyright 4 1 The Software shall be delivered su
128. rev 2 11 12 13 14 2 Software installation Software is ready for use A patient named Calibration Patient will be created and opened This patient can be used to store all calibration images for the installed de vice s Test the installation by opening a test image captured on a modality workstation Configure the desired user settings for the software See User manual General Settings chapter for details Repeat network client installation for each viewing workstation Instrumentarium Dental 29 2 Software installation 30 2 3 Network system 2 3 1 Network database Network database installation can be performed two ways Simple database installation using the software installer or Existing Database Installation EDBI In Simple Database Installation the MS SQL Server database engine and patient database are installed by the installation software In Existing Database Installation the patient database will be installed to an existing MS SQL Server 2 3 2 Simple Database installation 1 Insert software DVD into DVD ROM drive 2 If the InstallShield Wizard does not appear after a few moments browse to the software DVD and double click CLINIVIEWSetup exe to begin installation Note Ifthe User Account Control window appears you must allow changes to continue installation 3 Select CLINIVIEW Advanced installation CLINIVIEW 10 2 2 Select Features Select the feature you want to
129. ring the term of this Software License i the Software in object code form only and in accordance with the terms of this Software License and ii manuals and other documentation re lated to the Software You have no right to sublicense the Software and you are under the obligation to return the same to Licensor upon the expiration or termination of this Software License 2 2 You are entitled to use each licensed Software only on a single computer or terminal at any one time and if necessary for use on such computers or terminals to modify the Software or merge them into another pro gram all portions of the program continuing to be sub jectto this Software License in full Such other program must however conform to all applicable local laws reg ulations on patient imaging systems Licensor shall not be held liable for any damages resulting directly or indi rectly from a modification or merger of the Software Instrumentarium Dental 171 12 Software license 172 made by you even if Licensor approved such modifica tion or merger 2 3 You are granted no rights hereunder other than those expressly set out hereinabove and consequent ly all other activities related to the Software are prohib ited Such prohibited activities include but are not limited to i the deleting adding to copying modifying or transferring the Software or any part thereof or any copy or merged portion thereof in whole or in part ex cept as expr
130. rver Quick installation performs a default software installation Note Quick installation does not include DICOM features and Volumetric Tomography features These can be in stalled later as Add ons Network Client is an easy option to install software clients in a network environment This options installs software to its default location and creates a database connection to a local database in the network This install option includes software for image capturing processing and storing software client imaging drivers and database connection settings Network software installation does not include DICOM and Volumetric Tomography features these features can be installed later as Add ons Note Network install does not include DICOM or VT fea tures DICOM and VT features can be installed later as Add ons Advanced option allows a more customized software installation Advanced should be selected when preselected features in Quick and Network Client installations are not appropriate Quick and Network Client and install options are configured to cover most typical installation scenarios Together with the Advanced option it is possible to configure the installation for any installation environment Note Software installation may require you to restart your computer to complete the installation Please save all open documents and close all running programs prior to starting installation Note Do not install any of the softwar
131. s only available in License Server ver sion of the License Manager Double clicking a network license opens license usage window The license usage window shows in the topmost list all software features which are available in the selected network license Selecting a feature from the topmost list shows all activated network licenses which include the selected feature in the Licenses with selected feature list The list in the bottom of the window titled Users of selected feature shows the computer names where the selected feature is currently in use The Total license count is the sum of all licenses which include the selected feature Instrumentarium Dental 75 3 Licensing CLINIVIEW 76 Instrumentarium Dental 209804 rev 2 4 Driver installation 4 Driver installation 209804 rev 2 4 1 4 2 4 3 Compatible drivers and firmware must be installed before starting to use the device with the software Note Contact your distributor to check latest device drivers required by different product configurations Device drivers Device drivers are installed during software installation for all devices supported by the software Drivers can be upgraded using INSTRUMENTARIUM DENTAL Driver Updater See readme txt in the updater installation media for installation instructions NVIDIA drivers Validated NVIDIA drivers required for 3D image reconstruction are located on the software installation media in Drivers NVIDIA S
132. se choose your search and installation options DD Y O Search for the best driver in these locations Use the check boxes below to limit or expand the default search which includes local paths and removable media The best driver found will be installed Search removable media floppy CD ROM Include this location in the search CliniView Drivers PCIDr Don t search will choose the driver to install Choose this option to select the device driver from a list Windows does not guarantee that the driver you choose will be the best match for your hardware 7 Click Have Disk and browse a new PCI driver Ddx Drv inf from the software DVD Click Next Hardware Update Wizard Select the device driver you want to install for this hardware Select the manufacturer and model of your hardware device and then click Next If you have a disk that contains the driver you want to install click Have Disk v Show compatible hardware Model II Serial link PCI driver A This driver is not digitally signed Tell me why driver signing is important lt Back Next gt Cancel 8 The PCI driver is now updated Hardware Update Wizard Completing the Hardware Update ey Wizard SS The wizard has finished installing the software for Serial Link PCI Device Click Finish to close the wizard 82 Instrumentarium Dental 209804 rev 2 209804 rev 2 4 Driver installation 4 3 2 Uninstalling
133. se media files must be located in the same computer 4 Delete the whole Files folder under the image folder on the destination computer location e g C CVDATA DB Files Instrumentarium Dental 209804 rev 2 209804 rev 2 6 Software database 5 Copy the database backup file pidomsde dat from source your backup to the Backup folder on the des tination location e g C CVDATA Backup Replace existing pidbmsde dat if a file with that name already exists 6 Copy the whole Files folder including all files and sub folders from source your backup to destination e g C ACVDATA DB Files 7 Incase the database backup is from the same software database version as the new database perform step A In case the database backup is from the older soft ware database version than the new database perform step B A Run ImportDB bat location e g C Program Files CliniView Database Tools lmportDB bat and enter Username Password admin admin by default B See Old Backup Importer instructions found in instal lation media under Tools OldBackupImporter to import a backup from CliniView 7 1 0 2 or later to current ver sion of the software 8 Reconfigure the database connection ODBC of the clients as explained in the next chapter 6 How to re configure Database connection ODBC clients all CliniView 8 2 or later software on workstations and server if any Note Make sure that nobo
134. ses program directory defined in CLINIVIEW ini Windows directory Example Settings ProgramDir C Instrumentarium Imaging CLINIVIEW When starting the software the settings are read from the CLINIVIEW ini configuration file It is allowed to run only one instance of the software on a computer at a time If starting the software while the software is already running no additional instances of the program are started However the already running the software reads the Practice Management Interface section of the CLINIVIEW ini file and acts accordingly Finally the software sets all entries in the Practice Management Interface section to O The Practice Management Interface section in the CLINIVIEW ini file is described below The mandatory fields are USE PRACTICE MANAGEMENT If set to 1 the software reads the Practice Management Interface section at startup and on activation and users are not allowed to change or add new patients manually from the software user interface CLEAR PRACTICE MANAGEMENT AUTOMATICALLY If set to 1 the software resets USE PRACTICE MANAGEMENT and the patient keys every time the software reads the CLINIVIEW ini file If set to 0 the software does not reset to 0 the keys PATID Patient ID shall be unique and defined by PMS software Practice Management Interface PATBD defines date of birth which shall be formatted as defined in system regional settings CLEAR PRACTICE MANAGEMENT AUT
135. settings E X ar SOP Classes Worklist Storage Print Query Retrieve Storage SCP Click to save changes The DICOM configuration remains open m Cancel button Changes are not saved and the DICOM configura tion closes m OK button Click to save changes The DICOM configuration closes 5 1 General page General Storage Print r Local DICOM parameters Local Application Entity Title CY DICOM Local IP address Local station name M DICOM by Merge Library version 2 5 1 License number 1234567890ABCDEFGH M Retired Command Elements Initiator name for command messages Receiver name for command messages Send Length to End 0000 0001 in command messages I Send Recognition Code 0000 0010 in command messages Send Message ID 0000 0110 in command response messages Send Priority 0000 0700 in command response messages Instrumentarium Dental The General page gives an overview of the Local DICOM parameters DICOM settings xl 209804 rev 2 209804 rev 2 5 2 5 Configuring DICOM The Local Application Entity Title is the DICOM name for the software The name must be 1 to 16 characters in length letters A Z and or numbers 0 9 with no spaces Contact the hospital administrator to obtain the correct Application Entity Title AE title 5 1 1 DICOM License number The DICOM license key is managed through the license key of the softwa
136. t delete 48 hours after commitment Note Use this feature carefully since it removes captured X ray images from the software without user s explicit ac ceptance for each image and the images may need to be retrieved from the PACS if they are needed Instrumentarium Dental 209804 rev 2 209804 rev 2 5 Configuring DICOM Storage Commitment Advanced Maximum retry count for failed Commitment attempts This parameter defines the number of retries to be made if the Storage Commitment attempt fails for some reason Use 0 to disable the retry feature Retry interval for failed commitment attempts This parameter defines the wait time period between the retries Minutes are used Wait for commitment report in N ACTION Association Some Storage Commitment SCPs are able to send the Storage Commitment report within the same association as the Storage Commitment request This attribute defines the time period in seconds that the software Storage Commitment SCU waits for the report message Use 0 to always require separate association to be used for the Storage Commitment report Wait time for storage commitment report The time period in minutes that Storage Commitment SCU waits for Storage Commitment report after requesting it After this time period expires the status of the Storage Commitment task goes either into Waiting for Storage Commitment Retry if the retrying is enabled and there are retries left or to Storage Com
137. tandard Workgroup At least 1 GB 32 bit OS or 2 GB 64 bit OS 2 GHz Pentium 4 or better Monitor No special requirements 6 Instrumentarium Dental 209804 rev 2 209804 rev 2 1 Introduction DVD ROM DVD ROM Hard disk 8 GB free space Pan ceph images 4 GB 1000 panorama or cephalometric images Express 2 GB 1000 images Snapshot sensor DIGORA Toto Standard resolution mode 1 3 GB 1000 images High resolution mode 4 GB 1000 images OP300 100 GB 1000 CB3D study Volumetric Tomogra 37 GB 1000 VT Studies phy images Other software Anti virus software is recom mended to protect the system from viruses Backup A suitable backup system is re quired for safeguarding patient data and images Backup is solely the responsibility of the end user The manufacturer takes no responsibility for back up of user created data and im ages Instrumentarium Dental 1 Introduction 1 4 3 Minimum system requirements for Reco Server Operating system B Windows XP Professional OS SP3 32 bit B Windows Vista Business Ultimate Enterprise SP2 32 or 64 bit B Windows 7 Professional Ultimate Enterprise SP1 32 or 64 bit B Windows Server 2003 SP2 32 bit m Windows Server 2008 SP2 32 bit B Windows Server 2008 R2 SP1 BM Windows Server 2008 SP2 64 bit m Windows Server 2012 requires Windows Server 2003 hotfix KB
138. the driver If the driver installation fails remove the driver and then reinstall it The procedure is as follows 1 Open Control Panel and select Add Remove Hard ware Or open System Properties and select the Hardware tab Click Device Manager System Properties System Restore Automatic Updates ll Remote General Computer Name Hardware Advanced Device Manager The Device Manager lists all the hardware devices installed on your computer Use the Device Manager to change the properties of any device Device Manager Driver Signing lets vou make sure that installed drivers are compatible with Windows Windows Update lets you set up how Windows connects to Windows Update for drivers Hardware Profiles lt Hardware profiles provide a way for you to set up and store different hardware configurations Hardware Profiles 2 Click the driver and select Uninstall amp Device Manager File Action View Help e HM m gms m PALODEX 2251919 Computer Disk drives Display adapters Intel R 82945G Express Chipset Famil M Intel R 82945G Express Chipset Family DVD CD ROM drives Floppy disk controllers t A Floppy disk drives gy Human Interface Devices IDE ATAJATAPI controllers amp IEEE 1394 Bus host ontrollers i Keyboards Mice anid utl ier pointing devices Bl Network adapters E E Other devices Multimedia Audio Controller 5M Bus Controller E 2
139. this option increases performance Send Buffer This option sets the TCP IP send buffer size High er values for this buffer increases the network per formance of the tool kit for client SCU applications This value is larger than the PDU max length 5 9 Glossary ACR American College of Radiology Initiated the DICOM standardization effort in the early 80 s ACR NEMA Predecessor of the DICOM standard defined by the ACR and NEMA two versions were defined 1 0 and 2 0 AE Application Entity a software process which implements DICOM Most implementations use multiple AE s when implementing multiple Service Classes Attribute Attributes are the components of an information object definition 100 describing its properties DICOM Digital Imaging and Communications in Medicine standard IOD Information Object Definitions MergeCOM 3 Merge Technologies Inc provided toolkit performing low level DICOM communication 124 Instrumentarium Dental 209804 rev 2 209804 rev 2 5 Configuring DICOM Modality Acquisition system such as a CT MR US NM CR NEMA National Electrical Manufacturing Association PDU Protocol Data Unit a packet that is created at the DICOM lower level protocol SCP Service Class Provider SCU Service Class user SOP Service Object Pair TCPIIP Transmission Control Protocol Internet Protocol UID Unique Identifier Instrumentarium Dental 125 5 Configuring
140. tion key the software will operate in 30 day trial mode after the upgrade At the end of 30 days if you do not enter a new license activation key the software will stop working until a new license activation key is entered in the license manager Do you want to continue 5 If upgrading a version older than 10 2 0 then you must install one License Server in the local network Select License Server License Server r Description Thisis License Server installation License Server is installed to a server C No do not want to install License Server INSTRUMENTARIUM Installshield 138 Instrumentarium Dental 209804 rev 2 7 Upgrading the software 6 Review License Agreements and continue License agreements Do you accept the following license agreements CLINIVIEW software license View license Microsoft DirectX runtime license View license Microsoft SQL Server Express license View license Gp instrumentarium Installshield 7 Review the settings and click Next to start installation process Start Copying Files Review settings before copying files Setup is ready to install CLINIVIEW to this computer with the following settings Current Settings Features selected Database Licensing Server Client Dicom components Destination folder e INSTRUMENTARIUM C Program Files x86 Cliniview Database media folder CACVDATAS Database tables folder C Program Files 85
141. tional Small Network A small network system has one modality workstation connected to at least one imaging device for image capturing and viewing stations for image viewing and diagnosis In a small network system the modality workstation also acts as a database server storing all image data in the CLINIVIEW database and providing access to the image data for viewing workstations If network licenses are used the license server is typically installed in the modality workstation Note If network licenses are used the license server com puter must be running at all times to provide licenses to oth er workstations in the network Instrumentarium Dental 13 2 Software installation See chapter 2 2 to install a small network system CLINIVIEW client mage acquisition mage viewing and management PMS inte gration DICOM services optional Modality workstation VT client optional VT reco server optional CLINIVIEW database License Server 3D visualization software optional X ray device X ray device CLINIVIEW client Image viewing and management Viewing workstation DIC OM serv i ces optional VT client optional 3D visualization software optional Network In larger network environments such as imaging centers large dental clinics or hospitals the software components can be installed in multiple workstations with a dedicated server The database is typic
142. to all services there are following Storage SCU specific settings Retry count The number of retry attempts to made if the storing of an image has failed Use 0 to disable the retrying Retry interval The time period in minutes that is waited between the retries Storage page Set as Default button Allows the default destination to be set if there are more than two destination places in the Destination List Select the destination entry to be set as the default Click Default to set this destination as the default Storage page Verify button DICOM Verification All communications and image transfer with the remote application are accomplished using the DICOM protocol over a network using the TCP IP protocol stack Verify application level communication between DICOM application entities AE s click Verify If there are no selected items highlight in the destination list the Edit Delete Set as Default and Verify buttons are disabled Select the destination item to be verified All buttons are enabled Click Verify The DICOM Verification window gives information on the state of communication between the destination and computer If communication is successful a verification window appears showing all the parameters Instrumentarium Dental 209804 rev 2 209804 rev 2 5 Configuring DICOM DICOM Verification xl File Help m DICOM Parameters Application Entity Title Merge_store_scp Host name
143. to be changed A Fill in the patient data fields to be changed If the content of a specific data field is not needed to be changed set its value to 0 Rejstart the software To preselect a patient Set USE_PRACTICE_MANAGEMENT 1 Set PATID to match the patient to be preselected Set all data fields to 0 Rejstart the software To disable the practice management interface Set USE_PRACTICE_MANAGEMENT 0 Instrumentarium Dental 209804 rev 2 209804 rev 2 11 3 11 Using practice management interface Interface to access image information Note If images are brought into another software and to be used for diagnostic purposes this software must conform to applicable local laws and regulations on patient information softwares The software supports external application called PMSif which provides direct access to images in the software database CLINIVIEW ini has four fields which can be used together with PMSif to export the image Image ActivelmageGUID ActivelmagelD LastCaptureGUID Activelmagelndex Use ActivelmageGUID or ActivelmagelD to export the image visible in currently active image window from database ActivelmageGUID is preferred over ActivelmagelD retried Use LatestCapturedlmagelD to export latest captured saved image from database Only the latest ID s of the saved images are shown LastCapturelD and LastCaptureGUID are visible after the first image is captured Use A
144. trumentarium Dental 209804 rev2 209804 rev 2 1 Introduction Image dynamics grayscales 12 bit 4096 capture 16 bit 64k process amp handling 8 bit 256 display Image storage mode 16 bit enhanced File formats PNG 16 bit JPG 12 bit TIFF File compression PNG lossless JPG 100 60 quality TIFF lossless Typical file size Panoramic About 2 4 MB PNG 16 bits Intraoral Sigma 0 4 1 6 MB PNG 16 bits Intraoral Sigma M 3 5 MB PNG 16 bits Intraoral Snapshot 3 5 MB PNG 16 bits Cephalometric 3 5 MB PNG 16 bits CB3D 60 350 MB Intra Express 0 3 2 MB PNG 16 bits VT projection series 11 imag es 8 MB PNG 16 bits VT slice series 30 MB MNG 16 bits Import Export file formats BMP D32 PNG JPG TIF DI COM JPG2000 MNG Instrumentarium Dental 1 Introduction 1 6 The software compatibility table Win Win Win Win Win Win Win dows dows dows dows 7 dows 7 dows8 dows 8 XP Vista Vista 32 bit 64 bit 32 bit 64 bit 32 bit 64 bit OP100 D X x s n 0 89999 OP100 D X X X X X X X s n 90000 gt OP200 D X X X X X X X OP200 D with x X X X X X X SmartNav OP30 X X X X X x X OP300 X X X X X X Sigma USB x X X X Sigma M X X X X X X X WLAN Snapshot X X X X X X X USB Express X X X X X X X KaVo Pan X X X X X X X exam KaVo Pan X X X X X X eXam Plus KaVo X X X X X X
145. ure you want to start remove archived images 154 Instrumentarium Dental 209804 rev 2 209804 rev 2 10 3 1 1 Settings 10 CLINIVIEW Manager Select PNG or JPG as the saving format Select 60 100 quality for JPG Compressing images may decrease the image quality For VT projection JPG images the image quality cannot be chosen For VT slice images the file format choices are PNG and TIF xl gt File format and quality Photographic png VT Projection png hd png M 106 Quality z VT Reconstruction Modality File Format Image Quality Panoramic pna fico ouais Cephalometric png X 100 Quay Intraoral png i 1100 Quality 100 Quality 100 Quality Instrumentarium Dental 155 10 CLINIVIEW Manager 156 10 3 1 2 Image folder location Note Do not use drive mapping when changing the data directory The software database backup will not work when a mapped network drive is used to access the CLINI VIEWData folder If you have a network installation please only use an UNC path to define the data directory location in CLINIVIEW Manager 1 To change data directory images select Location from CLINIVIEW Manager dialog Ff Define data Directory xl Data Directory WEVSERVER T KUNCVDATA Browse Browse the main directory for the images If you have network installation then use UNC Path e g serverNcvdata The image directory shal
146. ver found will be installed Search removable media floppy CD ROM Include this location in the search N Don t search will choose the driver to install Choose this option to select the device driver from a list Windows does not guarantee that the driver you choose will be the best match for your hardware 3 Select Imaging devices and Click Next Found New Hardware Wizard Hardware Type Select a hardware type and then click Next Common hardware types gt wy Infrared devices Keyboards Medium Changers Mice and other pointing devices 5 Modems E Monitors NJ Multifunction adapters Syl Muilta serial adantara Instrumentarium Dental 209804 rev 2 209804 rev 2 4 Driver installation 4 Click Have Disk Found New Hardware Wizard Select the device driver you want to install for this hardware CF Select the manufacturer and model of your hardware device and then click Next If you have a disk that contains the driver pou want to install click Have Disk Unable to find any drivers for this device Cum os 5 Insert the software installation DVD into the DVD ROM and browse the PCI driver DdxDrv inf from path Clin iView DVD gt Drivers PCIDrv Install From Disk i Insert the manufacturer s installation disk and then make sure that the correct drive is selected below Copy manufacturer s files from m J Come 6 Click OK Install From Dis
147. ware Intraoral Camera interface WDM Windows Driver Model a video format supported by the soft ware Intraoral Camera interface WLAN Wireless Local Area Network Instrumentarium Dental 1 Introduction 1 4 System requirements The below requirements are the minimum required to install and use the software for basic 2D imaging When using the software together with an imaging unit please refer to the unit installation manual for additional requirements 3D units specifically have additional computer requirements not listed below 1 4 1 Minimum system requirements for the software client Operating System B Windows XP Professional OS SP3 32 bit B Windows Vista Business Ultimate Enterprise SP2 32 or 64 bit B Windows 7 Professional Ultimate Enterprise SP1 32 or 64 bit B Windows 8 Pro Enterprise 32 or 64 bit B Windows Server 2008 SP2 32 bit B Windows Server 2008 SP2 64 bit requires installation of Desktop Experience Memory RAM At least 1 GB 32 bit OS or 2 GB 64 bit OS Processor 2 GHz Pentium 4 or better Hard disk 8 GB free space DVD ROM DVD ROM for installation Keyboard Yes Mouse Yes Network card 10 100 1000 Mb s Ethernet Monitor 19 or larger recommended capable of 1280 x 1024 resolu tion 24 bit color or better PCI slot PCI slot for OP capture card in OP acquisition PC USB port USB port for Sigma Sigma M and Snapshot Instrumentarium
Download Pdf Manuals
Related Search
Related Contents
User Manual PRS-650 ユーザーガイド(取扱説明書) Manuel N6 VF_ok_im comp_20012010 Star Micronics NX-2480 User's Manual Kenwood AT358 Non-contact Forehead IR Thermometer Deutsch - WETRAVENT Pliego de Prescripciones Técnicas 325教室 User`s Manual Copyright © All rights reserved.
Failed to retrieve file