Sensidyne Gilian Gilibrator 2 Flow Monitoring

image

Contents

1. a specified number of samples have been taken You can also choose to save your data manually Additionally you have the option of specifying the interval no of samples taken before automatically saving the file range 1 99 Data files can also be saved or printed without having to use any menus or sub menus by clicking on the screen buttons see screen illustration on front cover Sensidyne Document No 360 0049 01 Rev A 5 Gilian Gilibrator 2 Flow Monitoring Software Set Graphic Display Option Allows you to activate or deactivate the Graphic Display When the Graphic Display is activated data will appear in both list and graph for mats as samples are taken The Graphic Display refer to front cover has red vertical lines to indicate 5 deviation in flow rate The center green line indicates the flow rate you wish to establish You can change this value simply by clicking on the green button above the center line The value you enter depends on the type of flow cell you are using If you are using a Low Flow or Standard Flow cell enter the value in cc min If you are using a High Flow cell enter the value in Liters Per Minute LPM Set Up and Operation Disable any screen savers first Make certain the Flow Monitoring soft ware is running and the Gilibrator 2 unit is turned OFF Connect one end of the Interface Serial Cable to the printer jack on the Gilibrator 2 Connect the other end of the cable to the seria
2. ADHERING TO ALL FEDERAL STATE AND LOCAL ENVIRONMENTAL AND OCCUPATIONAL HEALTH AND SAFETY LAWS AND REGULATIONS THE SELLER SHALL NOT BE LIABLE FOR DIRECT INDIRECT CONSEQUENTIAL INCIDEN TAL OR OTHER DAMAGES RESULTING FROM THE SALE AND USE OF ANY GOODS AND SELLERS LIABILITY HEREUNDER SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF ANY GOODS FOUND DEFECTIVE THIS WARRANTY IS LIEU OF ALL OTHER WARRAN TIES EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRAN TIES OF MERCHANTABILITY AND FITNESS FOR USE OR FOR A PARTICULAR PURPOSE WHICH ARE EXPRESSLY DISCLAIMED Sensidyne Document No 360 0049 01 Rev A 3 Gilian Gilibrator 2 Flow Monitoring Software What s Included The Gilibrator 2 Flow Monitoring Software Kit 811 0501 01 contains the following items e Special 6 Foot Serial Cable 850082 Gilibrator 2 Side D SUB 25 pin male PC Side D SUB 9 pin female e Program CD 611 0501 01 User Manual 360 0049 01 Introduction The Gilibrator 2 Flow Monitoring GFM software is a Windows based software program that runs on Microsoft Windows 98 or later The software allows Gilibrator 2 measurement data to be stored on a hard drive or other storage media printed on a standard printer or used in a spreadsheet or a word processing program IMPORTANT For complete instructions on using your Gilibrator 2 Calibration System re fer to the Operation 8 Service manual 850190M
3. Gilian Gilibrator 2 Flow Monitoring Software Version 2 0 for Windows Windows 98 or later 8 Gilibrator 2 Flow Monitoring Software Action Options Help Gilibrator 2 Opening existing file DATE TIME GILIBRATOR S N 205315 o PUMP S N 800508 OPERATOR fJohnSmth 00 Save to File CAGFM SAMPLE TXT Print FLOW AVERAGE SAMPLES STD DEVIATION 5 2200 555 USER MANUAL Dil TDIA Y IVE 16333 Bay Vista Dr Clearwater FL 33760 800 451 9444 727 539 0550 FAX Revision A Document No 360 0049 01 Gilian Gilibrator 2 Flow Monitoring Software PROPRIETARY NOTICE This manual was prepared exclusively for the owner of the Gilian Gilibrator 2 Flow Monitoring Software Used with the Gilibrator 2 Calibration System The material within this manual is proprietary information of Sensidyne Inc and is to be used only to understand operate and service the instrument By receiv ing this document the recipient agrees that neither this document nor the information disclosed within nor any part shall be reproduced or transferred physically electronically or in any form or used or dis closed to others for manufacturing or for any other purpose except as specifically authorized in writing by Sensidyne Inc COPYRIGHT NOTICE O 2004 Sensidyne Inc All Rights Reserved No part of this document may be reproduced transmitted tr
4. Software Installation You must have administrator rights for installation You also must first install the NET framework included on CD To install the GFM software perform the following steps Please quit all running application programs before installing the GFM software 1 Insert the Program CD into the CD drive if not already inserted 2 From the START menu select RUN Click on BROWSE to locate your CD drive 3 Type setup then click OK or hit ENTER to run the installation program 4 Sensidyne Document No 360 0049 01 Rev A Gilian Gilibrator 2 Flow Monitoring Software 4 Follow the on screen instructions to complete the installation 5 When the installation is complete you will be brought back to the desktop where a Sensidyne Gilibrator Flow Monitoring Software icon has been created Double click on the icon to start the program Action Menu The Action Menu contains the following sub menus New File Creates a blank file to receive data from the Gilibrator 2 Open file Opens a previously saved data file Save to file Saves your data file to a hard drive or a floppy drive Setup Printer Allows you to set the options for your primary printer Print Prints a formatted report of your data file Options Menu Set Com Port Allows you to set the Communications port to either COM1 or COM2 Set Saving Option Allows to set the program to automatically save your data file after
5. anscribed stored in a retrieval system or translated into any language in any form by any means without the prior written permission of Sensidyne Inc TRADEMARK NOTICE Sensidyne the Sensidyne logo Gilian and the Gilian logo are registered trademarks of Sensidyne Inc The trademarks and service marks are protected through use and registration in the United States Other names are trademarks or service marks of their respective holders SOFTWARE LICENSE The Gilibrator 2 Flow Monitoring Software is the property of Sensidyne Inc and shall remain the property of Sensidyne Inc in perpetuity The software is protected by US and international copyright laws and is licensed for specific use with the Gilibrator 2 Calibration System The user may NOT reverse engineer disassemble decompile or make any attemptto discoverthe source code ofthe software The software may NOT be translated copied merged or modified in any way The user may NOT sublicense rent or lease any portion of the software The right to use this software terminates automatically if any part of this license is violated DISCLAIMER THE SELLER ASSUMES NO RESPONSIBILITY WHATSOEVER TO ANY PARTY WHOSO EVER FOR ANY PROPERTY DAMAGE PERSONAL INJURY OR DEATH RECEIVED BY OR RESULTING FROM IN WHOLE OR IN PART THE IMPROPER USE INSTALLATION OR STORAGE OF THIS PRODUCT BY THE USER PERSON FIRM ENTITY CORPORATION OR PARTY NOT ADHERING TO THE INSTRUCTIONS AND WARNINGS OR NOT
6. l port on your com puter COM1 or COM2 only Only use Gilian serial cable PN 780 0002 01 No other cable will work Turn ON the Gilibrator 2 by pressing the ON button Let the unit go through the start up self test For older Gilibrator models press and hold the DELETE button while turning on the unit Wait for the RUN light to turn off The flow monitoring software uses COM2 as the default serial port If you decide to use COM1 instead first launch the GFM program Select Set Com Port from the Options menu then select COM1 Before beginning sampling enter the required information in the GILIBRATOR S N PUMP S N and OPERATOR fields hit the TAB key to advance to the next field This information will be saved with the file Locate the folder where you want the data file to be saved Enter the name of the file then click OK 2 2 3 4 5 6 7 6 Sensidyne Document No 360 0049 01 Rev A Gilian Gilibrator 2 Flow Monitoring Software 8 Operate the Gilibrator 2 unit normally one reading at a time All the data measurements will be sent to the computer screen Data for FLOW AVERAGE and Samples come directly from the unit The STD DEVIATION is computed by the program according to the fol lowing formula o 1 where 0 standard deviation x flow value n no of samples 9 Upto 99 readings may be saved to a file On the 100th sample the Gili brator does a
7. n automatic reset causing previous data to be lost unless first saved to a file Important data should be saved prior to 100th sample and a new session started Using a new file name for the new session other wise the old file will overwritten Miscellaneous e save the sample data at any time click on the Save to File button e To print out a graph of the sample data click on the Print button e clear the sample data collected so far and start a new session of flow monitoring press and hold the RESET button on the Gilibrator 2 until the sample data list clears itself e delete the sample just collected press the Delete button on the Gili brator 2 Data may not print or graph bars may obscure data if the data are out of 5 range Also may not print if data are incomplete or missing NOTES If you get an error message answer the following questions Does your computer have at least one serial port available Did you choose the proper serial port for your communication Did you check the cable connection Is the Gilibrator 2 battery pack fully charged Sensidyne Document No 360 0049 01 Rev A 7 Sensidyne Inc 16333 Bay Vista Drive Clearwater Florida 33760 USA Certificate No 970084 800 451 9444 727 530 3602 727 539 0550 fax www sensidyne com info sensidyne com

Download Pdf Manuals

image

Related Search

Related Contents

MGE-400  Wells COUNTERTOP WARMERS SMPT User's Manual  IUCLID 5 Guidance and Support  HD 10/25 S HD 10/25 S Plus HD 10/25 SX Plus HD 13  Samsung GT-M3200 Εγχειρίδιο χρήσης  Guía de instalación rápida NS-DV111080F / NS  PhoneSuite Extension User's Manual  Matrix Appliances MS001SS  Télécharger - Vestel France  FICHA TECNICA LIMPIADOR Y DESINFCTANTE. PINOWELL  