SERIES 740 VALVES PNEUMATIC DIRECTIONAL CONTROL
Contents
1. See next page for U L recognized and CSA approved coils Series 740 Valves Double solenoid 5 3 and U L recognized CSA approved models A AVENTICS 4 Way 3 Position Double Solenoid Operated Diaphragm Poppet Valve NOTE Electrical connector must be ordered separately One per solenoid required see Solenoid Connectors page All valves on this page come with 3 8 tube nuts designed to accommodate 3 8 x 0 062 wall poly tubing NEW PART NO OLD PART NO DESCRIPTION SYMBOL CLOSED CENTER VERSION R432016670 R432016671 R432016672 R432016673 R432016674 R432016675 R432002438 PW 067717 00003 6 VDC PW 067717 00004 12 VDC PW 067717 00005 24 VDC without coil EXHAUST OPEN CENTER VERSION R432016665 R432016666 R432016667 R432016668 R432006669 R432002439 PW 067716 00004 12 VDC PW 067716 00005 24 VDC without coil PW 067717 00001 110 VAC 50 Hz 120 VAC 60 Hz PW 067717 00002 220 VAC 50 Hz 240 VAC 60 Hz PW 067717 00006 24 VAC 50 60 Hz PW 067716 00001 110 VAC 50 Hz 120VAC 60 Hz PW 067716 00002 220 VAC 50 Hz 240 VAC 60 Hz PW 067716 00006 24 VAC 50 60 Hz NTI 3 15 eu StUIHIHE ESS 3 15 Warning Do not energize both solenoids at same time or all ports may be pressurized or exhausted 4 Way 2 Position Solenoid Operated Valves With U L Recognized amp CSA Approved Coils PART NO DESCRIPTION R432034081 R432034082 R432034083 5 2 Single Solenoid w 1
2. 062 wall poly tubing 5 16 O D x 0 040 wall nylon tubing 8mm x 1 00mm wall poly tubing Requires optional tube nut kit R432015289 Valves designed for 10mm O D x 1mm wall poly tubing are also available Adapters available 1 4 O D x 0 040 wall poly tubing Tube nuts are supplied with each valve for 3 8 x 0 062 wall poly tubing Features e NEMA 4 Electrical protection e UL recognized amp CSA approved coils version available e Packaged as a cylinder valve combination with TaskMaster cylinders sizes 1 1 2 thru 4 See catalog SC 200 Integrated fittings Adjustable built in flow controls in R and S exhausts on two position valves e Cycle life 20 to 150 million cycles Response time for 24VDC single solenoid valve at supply pressure 85 psi On 0 77 psi 18ms or less Off 85 8 psi 32 ms or less 52 2 ej et ni Series 740 Valves Single and double solenoid 5 2 A AVENTICS 4 Way 2 Position NOTE All dimensions expressed in in Solenoid Operated Diaphragm Poppet Valve NOTE Electrical connector must be ordered separately One per solenoid required see Solenoid Connectors page All valves on this page come with 3 8 tube nuts designed to DOUBLE SOLENOID OPERATED accommodate 3 8 x 0 062 wall poly tubing Valves with tube nuts for 5 16 8mm tubing 10mm tubing The external non locking manual override button may be pushed from and push in fitting style bodies a
3. 7 AVENTICS SERIES 740 VALVES PNEUMATIC DIRECTIONAL CONTROL Rexroth Pneumatics Series 740 Valves Specifications and features AVENTICS 4 Way 2 amp 3 Position Solenoid amp Air Pilot Operated Standard fittings Push in fittings Diaphragm Poppet Valve Single and double solenoid Single and double solenoid Single and double air pilot Metric tubing only TECHNICAL DATA Port Sizes Integrated Fittings for 3 8 5 16 and 8mm tubing Push in fitting styles bodies available for metric tubing only 2 position only Working Pressure 20 PSI minimum 150 PSI maximum External Pilots not available Flow C 0 7 with Integrated Fittings Cy 1 3 comparable flow to threaded part valve Temperature Range Solenoid Valve 5 F to 122 F Air Pilot 5 F to 140 F Media Air either lubricated or non lubricated Materials Polyacetal Engineering plastic with Buna N seals and diaphragms Combination Manual Override Locking amp Non Locking ELECTRICAL DATA Standard Voltage Power Consumption all coils are rated for continuous duty Inrush Holding 24 VAC 50 60 Hz 110V 50 Hz 120V 60 Hz 220V 50 Hz 240V 6 4VA 3 7VA Voltage Tolerance 10 Except for Explosion proof and Intrinsically safe solenoids NOTE Electrical connectors must be ordered separately One per solenoid required See complete listing on Solenoid Connectors page Recommended Tubing Standard 3 8 O D gt x 0
4. AVENTICS will repair or replace F 0 B our works at its option any equipment which under normal conditions of use and service proves to be defective in material or workmanship at no charge to the purchaser No charge will be made for labor with respect to defects covered by this Warranty provided that the work is done by AVENTICS or any of its authorized service facilities However this Warranty does not cover expenses incurred in the removal and reinstallation of any product nor any downtime incurred whether or not proved defective All repairs and replacement parts provided under this Warranty policy will assume the identity for warranty purposes of the part replaced and the warranty on such replacement parts will expire when the warranty on the original part would have expired Claims must be submitted within thirty days of the failure or be subject to rejection This Warranty is not transferable beyond the first using purchaser Specifically excluded from this Warranty are failures caused by misuse neglect abuse improper operation or filtration extreme temperatures or unauthorized service or parts This Warranty also lexcludes the use of lubricants fluids or air line additives that are not compatible with seals or diaphragms used in the products This Warranty sets out the purchaser s exclusive remedies with respect to products covered by it whether for negligence or otherwise Neither AVENTICS nor any of its affiliates will be liab
5. fluid operation using fire resistant or other special types of fluids may require special packing and seals Consult the factory 2 WARNING MATERIAL COMPATIBILITY Damage to product seals or other parts caused by the use of non compatible lubricants oil additives or synthetic lubricants in the air system compressor or line lubrication devices voids the AVENTICS warranty and can result in product failure or other malfunction See lubrication recommendations below AIR LINE LUBRICANTS In service higher than 18 cycles per minute or with continuous flow of air through the device an air line lubricator is recommended Do not use line lubrication with vacuum products However the lubricator must be maintained since the oil will wash out the grease and lack of lubrication will greatly shorten the life expectancy The oils used in the lubricator must be compatible with the elastomers in the device The elastomers are normally BUNA N NEOPRENE VITON SILICONE and HYTREL AVENTICS recommends the use of only petroleum based oils without synthetic additives and with an aniline point between 180 F and 210 F COMPRESSOR LUBRICANTS All compressors with the exception of special oil free units pass oil mist or vapor from the internal crankcase lubricating system through to the compressed air Since even small amounts of non compatible lubricants can cause severe seal deterioration which could result in component and system failure
6. special care should be taken in selecting compatible compressor lubricants 3 WARNING INSTALLATION AND MOUNTING The user of these devices must conform to all applicable electrical mechanical piping and other codes in the installation operation or repair of these devices INSTALLATION Do not attempt to install operate or repair these devices without proper training in the technique of working on pneumatic or hydraulic systems and devices unless under trained supervision Compressed air and hydraulic systems contain high levels of stored energy Do not attempt to connect disconnect or repair these products when a system is under pressure Always exhaust or drain the pressure from a system before performing any service work Failure to do so can result in serious personal injury MOUNTING Devices should be mounted and positioned in such a manner that they cannot be accidentally operated 4 WARNING APPLICATION AND USE OF PRODUCTS The possibility does exist for any device or accessory to fail to operate properly through misuse wear or malfunction The user must consider these possibilities and should provide appropriate safe guards in the application or system design to prevent personal injury or property damage in the event of a malfunction 5 WARNING CONVERSION MAINTENANCE AND REPAIR When a device is disassembled for conversion to a different configuration maintenance or repair the device must be tested for leakage a
7. 15616 P 069344 00006 24 VAC 50 60Hz Single Solenoid R432015617 P 069345 00001 110VAC 50Hz 120VAC 60Hz Double Sol R432015618 P 069345 00002 220V 50Hz 240V 60Hz Double Solenoid R432015619 P 069345 00005 24 VDC Double Solenoid 3 POSITION VALVES Without Indicator Lights New Part Number Old Part Number Description R432008644 P 026564 00001 110VAC 50Hz 120VAC 60Hz Closed Ctr R432008645 P 026564 00005 12 VDC Closed Center R432008862 P 027873 00001 110VAC 50Hz 120VAC 60Hz Open Center R432008863 P 027873 00005 12 VDC Exhaust Open Center 57 Series 740 Valves Air pilot single and double al AVENTICS 4 Way I 2 Position NOTE All dimensions expressed in E Air Pilot Operated SINGLE AIR PILOT VALVES DOUBLE AIR PILOT VALVES Part No R432013808 ie Part No R432013810 is old P 067698 00000 old P 067700 00000 i HELA MEZA CONNESTION FOR CONNECTIONS FOR PILOT PORT PILOT PORTS COMMON 2201A 2 PLS 4055 22DIA 05 5 3PLS 6 Typical width of valve 1 38 35 0mm P I L 150 FOR DOUBLE AIR PILOT T 420 Manual override standard This unique PERA TING external non locking manual override P 90 button for the double air pilot may be R pushed from one side to the other to E o select which delivery port is pressurized H 2 Double Air Bleeder Valve U 30 Part No R432008442 old P 026125 00000 R E o OP
8. 2VDC 5 2 Single Solenoid w 24VDC 5 2 Single Solenoid w 110VAC 50 60Hz R432034084 R432034085 R432034086 5 2 Double Solenoid w 12VDC 5 2 Double Solenoid w 24VDC 5 2 Double Solenoid w 110VAC 50 60Hz R432034087 R432034088 R432034089 5 3 Closed Center w 12VDC 5 3 Closed Center w 24VDC 5 3 Closed Center w 110VAC 50 60Hz R432034090 R432034091 R432034092 5 3 Open Center w 12VDC 5 3 Open Center w 24VDC 5 3 Open Center w 110VAC 50 60Hz 54 These valves do not include solenoid connectors Order one per solenoid Dimensions are the same as our standard models Series 740 Valves Intrinsically safe solenoid valves 5 2 g AVENTICS 4 Way 2 Position intrinsically Safe Solenoid Valves for Hazardous Locations Classes II and Hi Div Groups A B C D E F and G For use in low voltage 24VDC intrinsically safe applications No other voltage is approved Comes with standard non lighted DIN solenoid connector Must be connected to an FM Approved Zener Diode Barrier Maximum valve pressure is 115 PSI FM Approved Barrier Manufacturers Stahl Incorporated Woburn MA Single Solenoid Model Part No R432008894 old no P 028044 00005 Request Application Memo 35 and ADV 300 1SSV for Intrinsically Safe Valve information and Stahl Barrier part numbers installation Information Ce a INT SAFE Approved GR ABCDEFG 3 HAZ 2 3 IN ACCORDA
9. 651 PW 027897 00001 110 VAC 50 Hz 120VAC 60 Hz Double Solenoid Double R432016652 PW 027897 00002 220 VAC 50 Hz 240VAC 60 Hz Double Solenoid Solenoid R432030385 PW 027897 00004 12 VDC Double Solenoid R432016653 PW 027897 00005 24 VDC Double Solenoid R432016654 PW 028797 00006 24 VAC 505 60 Hz Double Solenoid 2 Position Push in fittings 10mm O D tubing NEW PART NO OLD PART NO DESCRIPTION Single 5727475280 572 747 528 0 220 VAC 50 Hz 240vac 60 Hz Single Solenoid Solenoid 5727470220 572 747 022 0 24 VDC Single Solenoid 5727475302 572 747 530 2 Base Valve No Solenoid NEW PART NO OLD PART NO DESCRIPTION Double 5727485280 572 748 528 0 220 VAC 50 Hz 240vac 60 Hz Double Solenoid 5727480220 572 748 022 0 24 VDC Double Solenoid Solenoid 5727485302 572 748 530 2 Base Valve No Solenoid Base valves are supplied without coil s or connector s which must be ordered separately see later page Series 740 Valve with 10mm Supply and Delivery Ports for higher flow applications 2 Position Note Use with 10mm O D x 1mm wall poly tubing NEW PART NO OLD PART NO DESCRIPTION R432015405 P 068700 K0000 Single Solenoid R432015410 P 068704 K0000 Double Solenoid 10mm Valves are supplied without coil s or connector s which must be ordered separately see later page 56 Series 740 Valves Extra corrosion resistant models g AVENTICS 4 Way 2 and 3 Position So
10. ERATION P 9 X 60 ao ee ae Exhausting either air pilot port while the s opposite port is still pressurized will shift l WORKING PRESSURE PSI the valve Valve features stainless steel fasteners for Pilot Operating Range for Double corrosion resistance Air Pilot Valve SS EE 58 Series 740 Valves Manifolds and gang stacking O AVENTICS 4 Way 2 and 3 Position NOTE All dimensions expressed in 4 Manifold Mounts amp Gang Stacking Manifold Mounting Snap Together Assembly Gang Stacking Arrangement Factory assembled manifolds also available NEW PART NO OLD PART NO DESCRIPTION SHEAR PLUG KNOCKOUT Ganged assembly common R432013811 P 067701 00000 Inlet Segment ORDERING EXAMPLE supply pressure obtainable by R432013812 P 067702 00000 End Segment ae pinot knockout shear plugs R432013813 P 067703 00000 Station Segment LE tia Li Mounting Accessories Kit R432015880 P 069881 00000 Single Subbase Identical to inlet Part Number R432013852 segment except rear cavities are Includes O ring for sealing blocked Used to manifold between the valve bodies and mount one valve only Part No R432013853 an inlet port blanking cap Bolts Required O rings included O Ring Kit included and Nuts are not included with manifold segments Stack can be held together and MANIFOLDS OUTLINE DIMENSIONS mounted with readily available 1 8 all thread material MANIFOLD INSTALLATION NOTE The first
11. NCE WTH MANUFAC Model 1259 06 400 MED By NASS MAGNET Seldering and plug connections suitabie for plugs according to 6 3 DIN 46247 or plug in connectors G h 1 iW a ov 4 POWER SUPPLY 25 RMS MAX NON HAZARDOUS LOCATION 3 FACTORY 1 For Dimension reference standard solenoid models NOTES 1 Maximum non hazardous voltage not to exceed 250 V RMS 2 Connect per barrier manufacturer s instructions 3 Connect per ISA RP 12 6 instructions 4 Maximum valve pressure 115 psi 5 Maximum inductance of solenoid operators when mounted on valve body not to exceed 375 mH Solenoid operator for 3 2 way function normally osed HAZARDOUS LOCATION CLASS I Il amp IH DIV 1 GROUPS A B C D E F AND G V MAX 28V I MAX 115mA Ci OuF Li OuH MUTUAL APPROVED 2 BLACK 14 1 W BARRIER L Rue 55 WHITE E ris SOLENOID VALVE Series 740 Valves Solenoid valves 5 2 with larger integrated fittings A AVENTICS 4 Way 2 Position Soienoid Operated Standard Series 740 valve with tube nuts for 5 16 0 040 wall nylon tubing or 8mm 1mm wall poly tubing Push in fittings are for 10mm 1mm wall poly tubing NOTE Electrical connectors must be ordered separately One per solenoid required see Solenoid Connectors page 2 Position Standard fittings NEW PART NO OLD PART NO DESCRIPTION R432016
12. Tube Nuts 3 ea for 3 8 converts the standard exhaust fitting to a 040 wall O D nylon tubing O D 062 wall poly tubing tube fitting for external piping or 8mm 1mm wall O D poly tubing R432015511 R432015330 R432015512 Manifold Blanking Plate Manifold Bushing Kit Individual Manifold Supply Pres use to block one segment for two supply pressures sure Kit mounts underneath mani fold segment not included R432015527 R432015526 R432015525 Double Elbow Fitting for 1 4 Double Elbow Fitting for 3 8 amp Barb Fitting for 1 4 I D O D tubing 5 16 O D tubing Reinforced Hose 60 Series 740 Valves Repair Kits A Repair Kits and Parts AVENTICS Part No Old Part No Description R432013884 P 067916 00000 Single Solenoid Body Repair Kit R432013885 P 067917 00000 Double Solenoid Body Repair Kit includes 3 position valves also R432013854 P 067817 00000 Air Pilot Operator Kit R432013816 P 067705 K0000 Single Solenoid Body Assembly R432013814 P 067704 K0000 Double Solenoid Body Assembly R432015687 P 069541 00000 Solenoid Repair Kit includes armature plunger spring amp seal 8994702802 H 899470 02802 Solenoid Retainer Kit R432013839 P 067782 00000 Valve Latch amp Spring R432013853 P 067816 00000 Valve Manifold Station O Ring Kit to attach valve to manifold Solenoid Ki
13. and last segment should always be securely mounted to a plate If more than five valves are used every third valve segment 7 should also be securely mounted 2 Heta 439 451 oe He 187 5 190 5 888 9 00 225 5 228 5 10 97 1049 263 5 ey a SS O O PSS A 2 STATION BY 8 STATION i O Ring P N 890701004 included with Segments Lubricate O Rings with Dow Coming 55 before assembly 266 5 801 5 8045 NOTE elow pa tab an manio segments 1337 1348 are scored This allows the end to be broken 839 5 342 5 off if desired making it tamper resistant thus requiring a screwdriver to remove valve 77s 60 5 Manifold End Manifold Manifold Segment Station Segment Inlet Segment R432013812 R432013813 R432013811 59 Series 740 Valves Accessories A ACCESSORIES R432015301 R432015479 R432015475 Elbow Fitting with nuts for Reducer Elbow Fitting with nut Reducer Fitting with nut 3 8 amp 5 16 O D tubing for 1 4 O D 040 wall tubing For 1 4 O D tubing 1 R432013850 8919905502 3 8 5 16 or 8 mm R432013852 Exhaust Tube Nut amp Silencer 8919905512 10 mm Sheer Plug Knockout for 2 kits shown Blanking Cap Stacking converts 4 way to 3 way Be U R432015513 R432015289 R432015287 Exhaust Fitting Adapter Kit Tube Nuts 3 ea for 5 16
14. e derived from our information The information given does not re lease the user from the obligation of own judgment and verification It must be remembered that our products are subject to a natural process of wear and aging Pages from SC 300 2015 02 online version Subject to change Printed in USA AVENTICS Corporation R th This document as well as the data specifications and other information set forth in it are the exclusive exro x property of AVENTICS It may not be reproduced or given to third parties without its consent Pneumatics
15. le for consequential or incidental damages or other losses or expenses incurred by reason of the use or sale of such products Our liability except as to title arising out of the sale use or operation of any product lor parts whether on warranty contract or negligence including claims for consequential or incidental damage shall not in any event lexceed the cost of replacing the defective products and upon expiration of the warranted period as herein provided all such liability is terminated THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED WHETHER FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE No attempt to alter amend or extend this Warranty shall be effective unless authorized in writing by an officer of AVENTICS Corporation IAVENTICS reserves the right to discontinue manufacture of any product or change product materials design or specifications without notice AVENTICS Corporation 1953 Mercer Road Lexington KY 40514 Tel 859 254 8031 Fax 800 489 1488 www aventics com us info us aventics com m 2 AVENTICS ORO AVENTICS Incorporated 5515 North Service Rd Suite 100 Burlington Ontario L7L 6A6 Tel 905 332 0399 Fax 905 332 8596 www aventics com ca info ca aventics com Further contacts www aventics com en contact The data specified only serve to describe the product No statements concerning a certain condition or suitability for a certain application can b
16. lenoid Operated Corrosion Resistant Series 740 Valves All fasteners and exposed metallic parts for the 2 position valves are 300 series stainless steel The adjustable built in flow control adjustment screws for the 3 position valves are zinc plated carbon steel with all other fasteners and exposed metallic parts 300 series stainless steel These valves are recommended for most daily wash down applications such as food processing breweries and dairy plants or anywhere else that corrosion can be a problem Dimensions are the same as standard valves CORROSION RESISTANT MODELS 2 POSITION VALVES Without Indicator Lights New Part Old Part Description Number Number R432015590 P 069294 00001 110VAC 50Hz 120VAC 60Hz Single Sol R432015591 P 069294 00002 220VAC 50Hz 240VAC 60Hz Single Sol R432015592 P 069294 00004 12 VDC Single Solenoid R432015593 P 069294 00005 24 VDC Single Solenoid R432015594 P 069294 00006 24 VAC 50 60Hz Single Solenoid R432015597 P 069297 00001 110VAC 50Hz 120VAC 60Hz Double Sol R432015598 P 069297 00002 220VAC 50Hz 240VAC 60Hz Double Sol R432015599 P 069297 00005 24 VDC Double Solenoid 2 POSITION VALVES With Indicator Lights New Part Old Part Description Number Number R432015613 P 069344 00001 110VAC 50Hz 120VAC 60Hz Single Sol R432015614 P 069344 00004 12 VDC Single Solenoid R432015615 P 069344 00005 24 VDC Single Solenoid R4320
17. nd proper operation after being reassembled and prior to installation MAINTENANCE AND REPAIR Maintenance periods should be scheduled in accordance with frequency of use and working conditions All AVENTICS products should provide a minimum of 1 000 000 cycles of maintenance free service when used and lubricated as recommended However these products should be visually inspected for defects and given an in system operating performance and leakage test once a year Where devices require a major repair as a result of the one million cycles one year or routine inspection the device must be disassembled cleaned inspected parts replaced as required rebuilt and tested for leakage and proper operation prior to installation See individual catalogs for specific cycle life estimates 6 PRODUCT CHANGES Product changes including specifications features designs and availability are subject to change at any time without notice For critical dimensions or specifications contact factory Many AVENTICS pneumatic valves and cylinders can operate with or without air line lubrication see individual sales catalogs for details Refer to the appropriate service manual for parts and service information most are available for download from www aventics com us LIMITATIONS OF WARRANTIES amp REMEDIES IAVENTICS warrants its products sold by it to be free from defects in material and workmanship to the following For twelve months after shipment
18. ts Includes Armature Coil amp Mtg Hardware Part No Old Part No Description R432015349 P 068648 00000 24 VAC 50 60Hz R432013840 P 067783 00000 110VAC 50Hz 120VAC 60Hz R432013841 P 067784 00000 220VAC 50Hz 240VAC 60Hz R432029180 P 067785 00000 6 VDC R432013842 P 067786 00000 12 VDC R432013843 P 067787 00000 24 VDC U L Recognized amp C S A Approved Coils Part No Description R432034080 12 VDC R432009779 24 VDC R432009778 110 VAC 50 60Hz Standard Coils Part No Model Number Description R432011985 P 048835 00001 110VAC 50Hz 120VAC 60Hz R432011986 P 048835 00002 220VAC 50Hz 240VAC 60Hz R432011988 P 048835 00004 12 VDC R432011989 P 048835 00005 24 VDC R432011990 P 048835 00006 24 VAC 50 60Hz Coils for Corrosion Resistant Valves Part No Model Number Description 5428457072 H 542845 07072 110VAC 50Hz 120VAC 60Hz 5428457082 H 542845 07082 220VAC 50Hz 240VAC 60Hz 5420507012 H 542050 07012 12 VDC 5450507022 H 542050 07022 24 VDC 5428457022 H 542845 07022 24 VAC 50 60Hz 61 NOTICE TO PRODUCT USERS 1 WARNING FLUID MEDIA AVENTICS pneumatic devices are designed and tested for use with filtered clean dry chemical free air at pressures and temperatures Within the specified limits of the device For use with media other than air or for human life support systems AVENTICS must be consulted Hydraulic cylinders are designed for operation with filtered clean petroleum based hydraulic
19. vailable one side to the other to select which delivery port is pressurized initially SINGLE SOLENOID WITH _ f AIR SPRING RETURN lft H 2 v SE 13 2 lt 12 2 POSITION Ls re FAI V 2 POSITION 5727495270 PW 067697 00001 110 VAC 50Hz 120 VAC 60Hz R432016659 PW 067715 00001 110 VAC 50Hz 120 VAC 60Hz R432016655 PW 067697 00002 220 VAC 50Hz 240 VAC 60Hz R432016660 PW 067715 00002 220 VAC 50Hz 240 VAC 60Hz R432016656 PW 067697 00003 6 VDC R432016661 PW 067715 00003 R432016657 PW 067697 00004 12 VDC R432016662 PW 067715 00004 5727490220 PW 067697 00005 24 VDC R432016663 PW 067715 00005 R432016658 PW 067697 00006 24 VAC 50 60 Hz R432016664 PW 067715 00006 R432002436 without coil R432002437 Unique Manual Override Feature Single solenoid valves are equipped with a convertible manual override button Valve comes standard with extended locking override By snipping tab off of plastic button override becomes non locking extended By snipping button at first scored line it becomes a flush non locking override By snipping at second scored line a flush locking override is obtained requiring a screwdriver to actuate 22 DIA 055 THE CONNECTOR CAN BE FIXED 3 PLS IN POSITIONS AT 90 INTERVALS 736 187 0 4 72 120 0 22 DIA 05 5 2 PLS 161 51 41 0 13 0 Typical width of valve 1 38 35 0mm
Download Pdf Manuals
Related Search
Related Contents
LITHIUM-Ionen Robot Rasenmäher 280/24V #95530 入 札 公 告 - 独立行政法人 日本芸術文化振興会 LABORATORIO MECATRONICA Par Janvier Ngnoulayé Département de FluxManual_Ver1.10_06 Tripp Lite 0SU52015 KVM switch Samsung 空净蓝旋风系列,等离子空气净化器,CARD值高达690m3/h,白色 AX60J7006WT 用户手册 Untitled - Papyrus - Université de Montréal Copyright © All rights reserved.