1. To take accurate measurements we recommend that you calibrate the probe once a year IM 701926 01E 1 2 6 Specifications Item Specifications Frequency bandwidth 2 DC to 50 MHz 3 dB Input type Balanced differential input Attenuation 1000 1 or 100 1 switchable Output offset voltage 3 5 mV or less after adjusting the ADJUST resistor Input resistance and capacitance typical 4 50 MQ approx 17 pF parallel with respect to ground Allowable differential voltage between and terminals 5000 V rms or less and 7000 Vpeak or less at 1000 1 attenuation 500 V rms or less and 700 Vpeak or less at 100 1 attenuation Allowable common mode voltage 5000 Vrms or less and 7000 Vpeak or less Maximum input voltage to ground 5 1000 Vrms CAT III 5000 Vrms or 7000 Vpeak CAT CMRR typical 4 80 dB or less at 60 Hz 60 dB or less at 20 kHz Output voltage 1 2 7 V DC ACpeak Value when the probe is used in combination with a measuring instrument whose input resistance is 50 kQ or higher Output impedance Used on a 1 MQ input oscilloscope Gain accuracy 2 3 2 Operating conditions 5 to 40 C 25 to 85 RH no condensation Storage conditions 30 to 70 C 25 to 85 RH no condensation Operating altitude 2000 m or less Storage altitude 3000 m or less Power requirements e Internal battery Four AA dry cell
2. personal injury or damage to the instrument A Ground the measuring instrument Make sure to connect the protective grounding terminal of the measuring instrument to ground Stop use if you suspect damage If you suspect that the probe is broken consult your nearest YOKOGAWA dealer Observe the maximum input voltage Do not apply voltage exceeding 7000 Vpeak between an input lead and ground or between two input leads The maximum input voltage is 7000 Vpeak regardless of whether 1000 1 or 100 1 attenuation is used Ground the probe Ground the probe by connecting the grounding conductor of the measuring instrument s power cable or another appropriate grounding conductor to the BNC shell and an auxiliary grounding terminal Before connecting the probe input terminal to the circuit under measurement ensure that the measuring instrument is grounded properly that the probe output connector is attached to the BNC connector of the measuring instrument and that the auxiliary grounding terminal is connected to a proper ground Do not remove the alligator clip s cover To prevent electric shock or fire do not remove the alligator clip s insulation cover Do not use in damp places To prevent electric shock do not use the probe in damp places Do not use in an explosive atmosphere To prevent fire and injury do not use the probe in a flammable or explosive atmosphere or near steam Do not touch exposed circuitry To prevent injury
3. indoor atmospheres with only non conductive pollution 10 When using devices with different measurement categories the lower measurement category applies For this probe because the measurement category of the alligator clip is lower when the probe and the alligator clip are used together measurement category CAT applies To use the probe under measurement category III conditions use it with the 701954 alligator clip 1000 Vrms CAT III sold separately IM 701926 01E 2 2
4. Series the 700938 or the 701934 3 Connect the BNC output connector to the oscilloscope input terminal and properly ground the auxiliary ground terminal If necessary use the auxiliary ground extension lead 4 Turn the power switch ON and warm up the probe for at least 30 minutes 5 Select the appropriate attenuation using the attenuation ratio selector For higher resolution and less noise when measuring signals less than or equal to 700 V switch the attenuation to 1 100 e When measuring signals greater than 700 V set the attenuation to 1 1000 6 f the offset voltage is large short the alligator clips and turn the ADJUST variable resistor DC voltage adjustment using an appropriate flat head screwdriver to adjust the offset voltage 7 Connect the two probe input leads to the two points of measurement differential measurement The performance declines if you only connect a probe input lead to a single point Make sure to connect both leads A To prevent electric shock and other accidents make sure to connect the probe output to the properly grounded oscilloscope so that the ground end shielded end of the BNC connector of the output cable is grounded Turn OFF the power to the circuit under measurement when connecting or disconnecting the probe from the circuit under measurement Connecting or removing the probe while the power is ON is dangerous Do not touch the probe after turning ON the power to the circuit under meas
5. a User s Model 701926 Manual High Voltage Differential Probe for the DL Series Thank you for purchasing the High Voltage Differential Probe 701926 for the DL Series To ensure correct use please read this manual thoroughly before beginning operation After reading this manual keep it in a safe place Contact information of Yokogawa offices worldwide is provided on the following sheet e PIM113 01Z2 List of worldwide contacts 5th Edition November 2015 YMI All Rights Reserved Copyright 2008 Yokogawa Electric Corporation All Rights Reserved Copyright 2010 Yokogawa Meters amp Instruments Corporation Printed in Japan YOKOGAWA IM 701926 01E 5th Edition Safety Precautions Make sure to observe the following safety precautions when handling the probe YOKOGAWA assumes no liability for the customer s failure to comply with these safety precautions Before you use the probe read the measuring instrument s manual to fully aware of its specifications and handling The following symbols are used on this instrument Warning handle with care Refer to the user s manual or service manual This symbol appears on dangerous locations on the instrument which require special instructions for proper handling or use The same symbol appears in the corresponding place in the manual to identify those instructions A Risk of electric shock Make sure to observe the following safety precautions to prevent electric shock
6. an be taken to prevent such occurrences Note Calls attention to information that is important for proper operation of the instrument 1 Description This probe provides differential inputs to be used with oscilloscopes with single ended inputs 2 Configuration The differential probe consists of the following parts and accessories Approx 90 cm Approx 50 cm Standard parts Parts No 1 Probe 2 High voltage alligator clip Two in a set Black BB099RC Red B8099RD 3 Ground extension lead length approx 100 cm 4 Power cable length approx 150 cm B9852MJ Power can be supplied from a YOKOGAWA measuring instrument 700938 or 701934 3 Probe Part Names ADJUST DC offset adjustment Power LED Attenuation ratio selector Power switch BNC output connector 4 Installing or Replacing Batteries Slide the lid on the back side of the probe and install or replace the four AA dry cells The probe is shipped from the factory without the batteries installed 5 Procedure 7 Connect the provided high voltage alligator clips to the probe input leads 2 Supply power to the probe by one of the following methods e Install four AA cells The power LED blinks if the battery level goes low If this message appears replace the dry cells Connect the appropriate power cable to an external power supply Connect the probe power cable to a probe power supply terminal on the DL
7. he dry cells is 5 V or higher or when using an external power supply 2 Atan ambient temperature 2345 C humidity 55 10 RH 30 minutes after the power is turned on 3 The accuracy is the total of the gain accuracy and offset voltage A Typical values are typical or mean values They are not strictly guaranteed 5 Frequency derating load reduction applies Input voltage derating amp 10000 2500 gt 1000 5 2 100 x 10 1M 10M 100M Frequency Hz 6 The power LED blinks if the battery level goes low If this message appears replace the dry cells When using an external power supply do not install dry cells 7 This equipment is for measurement category III CAT III Do not use it with measurement category IV CAT IV CAT III applies to measurement of the distribution level that is building wiring fixed installations CAT IV applies to measurement of the primary supply level that is overhead lines cable systems and so on 8 Measurement category CAT applies to measurement of circuits that are not directly connected to a main power source Forexample this category applies to measurement of secondary electric circuits in equipment across a transformer The estimatedtransient overvoltage for the 701926 is OV 9 Pollution degree applies to the degree of adhesion of a solid liquid or gas which deteriorates withstand voltage or surface resistivity Pollution degree 2 applies to normal
8. irement This marking indicates that you must not discard this electrical electronic product in domestic household waste Product Category With reference to the equipment types in the WEEE directive this product is classified as a Monitoring and control instruments product When disposing products in the EU contact your local Yokogawa Europe B V office Do not dispose in domestic household waste Authorized Representative in the EEA Yokogawa Europe B V is the authorized representative of Yokogawa Meters amp Instruments Corporation for this product in the EEA To contact Yokogawa Europe B V see the separate list of worldwide contacts PIM 113 0122 The following symbols are used in this manual A Improper handling or use can lead to injury to the user or damage to the instrument This symbol appears on the instrument to indicate that the user must refer to the user s manual for special instructions The same symbol appears in the corresponding place in the user s manual to identify those instructions In the manual the symbol is used in conjunction with the word WARNING or CAUTION NANN e Calls attention to actions or conditions that could cause serious or fatal injury to the user and precautions that can be taken to prevent such occurrences CAUTION Calls attention to actions or conditions that could cause light injury to the user or damage to the instrument or the user s data and precautions that c
9. remove metallic objects and jewelry such as rings and watches Do not touch exposed live connections or components Do not disassemble or modify Do not disassemble or modify the product YOKOGAWA assumes no liability if you disassemble or modify the product A CAUTION Use the correct power supply Power the probe by using four AA dry cells by using a 6 VDC 200 mA or 9 VDC 150 mA external power supply or by connecting a probe power cable to the DL Series probe power supply terminal the 700938 or the 701934 Operating the probe while using a power supply exceeding the specified voltage may cause damage to the instrument Turn OFF the probe when connecting an external power supply Turn the probe power switch OFF when connecting or disconnecting from the external power supply Do not install AA batteries when using an external power supply Conditions of use This product has not been designed or manufactured for applications in which high reliability is required over a long time period Operating environment limitations This product is a Class A for industrial environments product Operation of this product in a residential area may cause radio interference in which case the user will be required to correct the interference Waste Electrical and Electronic Equipment Waste Electrical and Electronic Equipment WEEE Directive K This directive is valid only in the EU This product complies with the WEEE directive marking requ
10. s External power supply 6 VDC 200 mA or higher or 9 VDC 150 mA or higher with a positive center pin e Power is supplied through the dedicated cable B9852MJ from a YOKOGAWA measuring instrument s probe power supply terminal or from a 700938 or 701934 probe power supply Battery life Approx 7 hours under continuous use when using alkaline dry cells Warm up time At least 30 minutes Recommended calibration period 1 year External dimensions 202 mm x 83 mm x 38 mm excluding connector and cable Weight Approx 500 g excluding batteries Safety standards Complying standards Probe excluding the alligator clip EN61010 031 Measurement category III 7 Measurement category l Pollution degree 2 Alligator clip BB099RC 8099RD EN61010 031 Measurement category l Pollution degree 2 9 Probe and alligator clip 1 EN61010 031 Measurement category l Pollution degree 2 9 1000 Vrms 5000 Vrms 7000 Vpeak 5000 Vrms 7000 Vpeak 5000 Vrms 7000 Vpeak Emission Complying standards EN61326 1 Class A EN55011 Class A Group 1 EMC standards of Australia and New Zealand EN55011 Class A Group 1 This product is a Class A for industrial environment product Operation of this product in a residential area may cause radio interference in which case the user is required to correct the interference Immunity Complying standards EN61326 1 Table 1 1 When the supply voltage from t
11. urement Do not remove the probe from the measuring instrument while the probe is connected to the circuit under measurement e When disconnecting the probe BNC output connector first turn OFF the power to the circuit under measurement Then disconnect the probe from the high voltage parts of the circuit under measurement e When replacing batteries or connecting an external power supply first turn OFF the power to the circuit under measurement Then remove the input lead from the circuit under measurement A CAUTION This probe is designed to measure the voltage difference between two points on the circuit under measurement It does not electrically isolate the circuit under measurement from the measuring instrument Use a soft cloth to clean the probe Be careful not to break the probe Do not immerse the probe in liquid or use abrasive cleaners on the probe Do not use benzene or other solvents on the probe e Turn the probe power switch OFF when connecting or disconnecting from the external power supply Do not install AA batteries when using an external power supply SSS ESS SSS SSS SSS SSS SSS SSS SSS SSS Note Accurate measurements may not be possible near objects with strong electromagnetic fields such as transformers large current circuits and wireless equipment Before use flip the attenuation switch back and forth several times The switch s electrical contacts can weaken if not used for long periods of time