MAC® 5500/MAC® 5500 HD
Contents
1. LL cece ee eee eee eees 167 Paper Maintenance cccccccsssssscecccecsssssscecccececssessceececesessssssceeceeseees 170 Setting the Correct Paper Size ce se eee pe Ku kelk E EAT da Wa ceases 170 Loading the Pdp6els s td ORE ROTER a E HER 171 Battery Main terae vitoria hp a k uie vo rm Vo e k y 172 charging THE Battery sso ores coe Ee e E E RE dent dee gh augers 172 Conditioning the Battery 1 555 loros 173 Replacing the Batter esc tes ree ease ie Pe s tee eek ipe et e oke Wade ye keta di 173 Replacing Leadwire Adapters eese 174 Troubleshooting General Troubleshooting Guidelines keke 177 Visual ISDE CEION eR 177 Performance Problems icons 177 Unacceptable Noise Levels cad SED de isa 177 ACI TIPI Report Does Not Print si oet re ee et dee et e e den gena 178 External Device Does Not Record BP Readings sss 178 Treadmill Ergometer Does Not MOVe LE meme 178 System EFrOEFs eiii posparto 179 Report Formats Numeric Reports in Uter abt OMBRA SORS DEM SR RO 181 Additional RepoRts oer ethic qs aii 182 In Test Reports erede etae te sooo He S ka KES 3 P k VEBA k n W KEK N c R 183 MAC 5500 MAC 5500 HD 7 Exercise Final ReDOFES quita 184 EX rCI S R DORE COMES ns po qu oput e te equi ted tod orien 185 Master s Step Data Master s Step Table a 2
2. Damage or corrosion Product discoloration e Metal part corrosion Unit malfunction Voided warranty Use the following procedure to clean the equipment s exterior surfaces Be sure to observe all cautions when cleaning the device 1 Toclean wipe with a lightly moistened cloth Use a mild soap and water solution to moisten the cloth Do NOT use any of the following cleaning products or products that contain the same active ingredients and solutions which are known to cause the problems previously listed e Sani Cloth Wipes Ascepti Wipes HB Quat e Clorox Wipes they do not contain bleach e Over the counter detergents such as Fantastic Tilex and so on 2 To disinfect wipe with a soft lint free cloth moistened with an appropriate disinfectant Use the following solutions as recommended in the APIC Guidelines for Selection and Use of Disinfectants 1996 e Sodium hypochlorite 5 2 household bleach minimum 1 500 dilution minimum 100 ppm free chlorine and maximum 1 10 dilution e Any sodium hypochlorite wipe product that meets the previous guidelines can be used 3 Dry with a clean cloth or paper towel 164 MAC 5500 MAC 5500 HD 2046275 016A Cautions Maintenance Follow the cleaning instructions exactly e Wring excess disinfectant from wipe before using Never immerse the device cables or leadwires in any liquid as this may corrode metal contacts and affect signal qu
3. 14 13 12 11 10 9 Teme Tosaptan Function keys Selects screen menu functions Power button Powers the system on and off Delete key Erases typed characters Copy key Prints an additional copy ECG report 5 ECG key Acquires a 12SL resting ECG including measurements and interpretation MAC 5500 MAC 5500 HD 2046275 016A System Overview Name en TT Rhythm key Prints continuous ECG data which cannot be stored or transmitted Stop key Stops the writer from printing Arrow pad Moves the cursor left right up or down Pressing the center button selects the highlighted menu or screen item E Return key Enters information into the system Information key Provides additional user information 11 Spacebar Adds a space between typed characters or highlights screen items Option key Used to create special characters on non English keyboards Shift key Creates capital letters Press shift p to type P Keyboard Exercise Test Keys Option 3 4 1 2 EN m Test end Pretest Exercise Start tmill Recovery Recall Medians Comment STOP tmill 12 ld 12 1 Pretest Advances to the next stage within the current pretest phase 2 Exercise Advances the exercise test to the exercise phase or to the next stage within the current exercise phase 2046275 016A MAC 5500 M
4. After configuring your critical values you can save the configuration to an SD card which you can use to restore the critical value configuration in the case of a system failure or to quickly configure other systems NOTE The Critical Values option must be activated before you can configure the notifications Refer to Option Activation on page 126 for more information 2046275 016A MAC 5500 MAC 5500 HD 143 System Setup Notifications Setup To configure the critical value notifications log on to the System Setup screen select ECG gt Critical Values Setup and complete the fields described in the following tables Critical Values Notification Setup Enabled Enables or disables the critical value notifications Select Yes to notifications enable the critical value notifications Critical values Defines the password required to edit the critical values notifications password Blank by default Enter up to six characters to define the password Notification string Defines the text that introduces the critical values notifications The string immediately precedes trigger values on screen and in reports The default string is Critical Test Results Modify as necessary You can enter up to 29 characters NOTE This is a string from the 12SL Statement Library If you modify this string you must make the same modification to the statement in the 12SL Statement Library on the MUSE systems that communicate with this device Thi
5. Select the current hour and minute Language 128 To configure the system s display and report language log on to the System Setup screen select Basic System Language and complete the fields described in the following table Language Selection Select new language Select the desired language The language changes when you reboot the system MAC 5500 MAC 5500 HD 2046275 016A System Setup Power Up Options To configure the system s power up application log on to the System Setup screen select Basic System gt Power Up Options and complete the fields described in the following table NOTE For detailed instructions refer to Setting Up Power Up Function on page 116 Power Up Options Power Up Select the application that opens automatically when you start the Application system Options are Resting ECG Pediatric ECG Vector Loops 15 Lead ECG Order Manager Interface Order Manager Interface To configure the system s Order Manager log on to the System Setup screen select Basic System gt Order Manager Interface and complete the fields described in the following table Order Manager Interface Initial sort value Determines how the Order Manager initially sorts the ECGs Select one of the following values Patient name Patient ID Location Time Stat Create orders locally Determines whether you can manually create orders on the MAC system Select Yes to allow manual or
6. While cards from any manufacturer work with the system GE Healthcare recommends and provides cards from SanDisk Corporation MAC 5500 MAC 5500 HD 107 Using an SD Card Preparing the SD Card Before using the SD card you must know how to lock unlock insert eject and format the card Locking and Unlocking the SD Card You can lock an SD card to secure the data Before using the SD card unlock it by moving the lock tab into the unlocked position 1 This allows you to store data on or delete data from the card To prevent accidental deletion of data protect the SD card by moving the lock tab into the locked position 2 The tab should remain in the locked position until you are ready to copy data to or remove data from the card Inserting and Ejecting the SD Card To use the card insert it into the card reader on the back of the MAC system When it is properly inserted it will snap into place To remove the SD card from the slot press the card into the slot the slot is spring loaded and will eject the SD card Formatting the SD Card Most secure digital cards do not require formatting In the event an unformatted SD card is inserted into the system the following message will be displayed This SD Card cannot be read and requires formatting Formatting will destroy all data on this SD Card Are you sure you want to format 108 MAC 5500 MAC 5500 HD 2046275 016A Using an SD Card Select Yes
7. CAUTION INACCURATE PATIENT DATA Patient data may be retained from a previous patient Check the patient info screen for each new patient Data assigned to the wrong patient causes erroneous patient data that can affect diagnosis and treatment of the patientis Make sure that you enter patient data for the correct patient NOTE 2046275 016A The patient information you are required to enter depends on your system configuration Refer to Patient Questions on page 121 for a description of the patient information you are requested to enter MAC 5500 MAC 5500 HD 63 Entering Patient Information Manually Entering Patient Information You can manually enter patient data on all MAC systems 1 For each new patient select Patient Data The Patient Data entry window opens Using the arrow pad navigate from field to field and enter data as appropriate For more information on how to manually enter data in the MAC system refer to Entering Data on page 50 NOTE Our equipment contains several fields that can be filled in before performing an ECG Some of these fields must be filled in before performing an exam others are optional and therefore left to the user to assess whether they are needed to perform the exam The field Race is one of these optional fields It has been acknowledged by the medical profession as useful to analyze some pathologies You should be aware that in some jurisdictions the processing
8. Configure the settings as appropriate Refer to the corresponding function sections in this chapter for detailed descriptions of the settings When you are done configuring the section select Save Setup A list of options is displayed Do one of the following To save the settings to internal storage select To system Use this option to enable the changes on the system To save the settings to external storage select To SD Card MAC 5500 MAC 5500 HD 115 System Setup Use this option if you want to use the settings to quickly configure other MAC systems Be sure that an SD card is inserted into the system s card slot To cancel select Do not save setup 7 Select Main Menu to exit System Setup Setting Up Automatic Tasks The MAC system can be configured to perform the following tasks automatically Power up into a specific function Preview the ECG before analysis e Print a resting ECG report Print a signal averaged ECG report e Perform ACI TIPI Interpretation e Store an ECG e Transmit an ECG report Setting Up Power Up Function You can set up the system to start up into the function you use most often 1 Log into the System Setup function Refer to Process Overview on page 115 Select Basic System 3 Select Power Up Options 4 Select the function you want the system to load on startup For more information refer to Power Up Options on page 129 5 Press Return Setting Up
9. Dedicated Banana Dedicated Banana Dedicated Banana Dedicated Banana Dedicated Banana MAC 5500 MAC 5500 HD EC 36 in 90 cm R EC 36 in 90 cm L EC 40 in 102 cm F EC 40 in 102 cm N EC 26 in 66 cm C1 EC 26 in 66 cm C2 EC 26 in 66 cm C3 EC 26 in 66 cm C4 EC 26 in 66 cm C5 EC 26 in 66 cm C6 EC 26 in 66 cm E 2046275 016A Leadwires cont d Part Number 2020559 012 2020559 013 2020559 014 2020559 015 2020559 016 2020559 017 420101 001 420101 002 Leadwire Accessories The following electrode accessories have been approved for use with this device 2046275 016A Introduction CA CA CA CA CA CA M 14 ECG M 14 ECG M 14 ECG M 14 ECG M 14 ECG M 14 ECG Leadwire Leadwire Leadwire Leadwire Leadwire Leadwire Dedicated Banana Dedicated Banana Dedicated Banana Dedicated Banana Dedicated Banana Dedicated Banana EC 26 in 66 cm H EC 26 in 66 cm EC 26 in 66 cm M EC 26 in 66 cm C3R EC 26 in 66 cm CAR EC 26 in 66 cm C7 CAM 14 ECG Leadwire Set Universal mixed length 14 set CAM 14 ECG Leadwire Set Universal mixed length 10 set Leadwire Accessories ECG Adapters and Connectors The following adapters and connectors have been approved for use with this device Part Number 2001926 001 401089 003 414763 002 ECG Adapters and Connectors Part Number 406551 033 4065
10. Determines whether the system will print ECG test information on the bottom of the ECG reports Select Yes to print the ECG information on the report Determines whether the system will print the patient information in a barcode format on the report Select Yes to print the bar code Determines whether the system will shut down automatically after a set number of minutes if a key is not pressed e To disable automatic shutdown enter 0 in the field Toenable automatic shutdown enter the number of minutes to wait before shutdown For example if you enter 5 the system will shut down automatically if a key is not pressed within 5 minutes Determines whether the serial port will receive continuous power Select Yes to continuously power the serial port Prevents unauthorized persons from accessing the System Setup functions The password must be entered to access the System Setup menus Enter a 6 character password The default password is SYSTEM Keep track of all assigned passwords MAC 5500 MAC 5500 HD 2046275 016A Miscellaneous Setup cont d Overread password Device password SD Card Storage Only Patient Questions To configure the prompts that are displayed when you select Patient Data in the Resting ECG application log on to the System Setup screen select Basic System gt 2046275 016A Patient Questions an Patient Questions ID Required ID length System Setup Prevents unauthoriz
11. Graph latest heart rate The top horizontal line is the maximum predicted heart rate 220 age The line below that is the target heart rate a percentage of 220 age At the start of Exercise phase a third line displays the resting heart rate Workload Level ndicates the units of measurement and can be changed Phase and Stage Clocks ndicates the current duration of the phase and stage The top clock displays the total time in a phase The bottom clock displays the time in a stage During the Test End phase the top clock displays total time in the Exercise phase and the bottom clock displays total time in the Recovery phase 5 Current Phase and Stage ndicates what phase top name and stage bottom Name name are currently being performed EN Protocol Name dentifies the name of the protocol Rhythm Formats Displays the lead readings Refer to Chapter 14 System Setup for instructions on changing the leads being displayed Medians Displays the median of the current and pretest rhythms 44 MAC 5500 MAC 5500 HD 2046275 016A System Overview qum O Current Heart Rate Displays the patient s heart rate Determined using the three leads displayed on your screen during the pre test phase These leads can be changed during the test by selecting the Measurements function 10 Function Icon Indicates the Main Menu function currently being used In this example the Exercise12 function is being used Battery Stat
12. Press Location A list of locations opens Each location contains three elements e Location MAC 5500 MAC 5500 HD 2046275 016A Transmitting ECGs This identifies the connection method and includes the following Manual Dial Serial Line e MUSE Network Ethernet Line Phone Number For predefined modem locations this column will contain the location s phone number For Manual Dial locations this column will contain a question mark and a phone number must be entered if the location is selected For Serial Line MUSE Network and Ethernet Line this column will be blank Type This identifies the kind of location and includes the following e MUSE Network XML Output e ASCII Output Highlight the desired location and press Select A list of ECGs opens Select the ECGIS to transmit Press Transmit Transmitting ECGs Wirelessly If you purchased the MobileLink option you can transmit ECGs wirelessly NOTE 2046275 016A Performance of the MobileLink wireless system may vary due to changes in RF radio frequency properties of your site or environmental conditions If you are experiencing intermittent connectivity in certain areas of your facility it may be necessary to re initiate the process of transmitting to the MUSE system You may also wish to consult your hospital IT department or your local GE Healthcare networking professional regarding modification of your wireless LAN to improve system performanc
13. Process Overview on page 115 2 Select Basic System gt Option Activation 126 MAC 5500 MAC 5500 HD 2046275 016A 2046275 016A System Setup A list of the following options is displayed 12 Lead sT12 Enables 12 lead stress tests Exercise 15 Lead ST15 Enables 15 lead stress tests Exercise Hi Res HRES Enables QRS signal averaging PHi Res PRES Enables P wave signal averaging which enhances measurement accuracy by maximizing signal fidelity AT Modem MODM Enables transmission and receipt of data over an external AT modem FAX Modem FAXM Enables transmission and receipt of data over an external FAX modem Interpretation DIAG Enables the printing of 12SL diagnosis on ECG reports Remote Query RQRY Enables you to query MUSE databases to review and print ECG reports ACI TIPI TIPI Enables ACI TIPI analysis for resting ECGs This analysis generates a numerical score representing the probability that the patient has acute cardiac ischemia Gen 12SL GN12 Enables the use of gender and age specific interpretation criteria when generating 12SL diagnosis Color COLR Allows you select one of two color options for the display screen Master s Step MAST Enables the Master s Step stress test Available only in Japan Wireless WIFI Enables the transmission of ECGs over a wireless network Bar Code BCRD Enables collection of patient data via bar code Reader reader Card Reader MGRD Enables collection of patient
14. The following menu items are available during the recovery phase of the test Press to display a list of predefined events Edit Press during the recovery or test end phase to allow you to enter or edit patient data reason for test termination or comments Measurements Reestablish the median complex set the J point and select the three leads used to calculate heart rate Leads Select the leads used for Rhythm Lead 1 2 and 3 All Leads Lead Check or Lead Placement Test End Phase During the text end phase the system no longer acquires or stores ECG data or displays workload speed or grade information 1 Press and hold the Test end button to end the test and start the test end phase You MUST hold the Test end button for more than one second to activate This prevents the test from being stopped by an accidental key press 2 Select Reason for termination or Comments to enter information about this exercise test 2046275 016A MAC 5500 MAC 5500 HD 81 Exercise Stress Testing Select Continue to return to the Test End menu e A final report prints automatically if you selected this option in the Edit Protocol function select System Setup gt Exercise Test gt Final Report e To change the type of reports that print automatically see Final Report on page 151 To edit Patient Data Reason for termination or Comments select Edit You can edit this information until you select New Patient or Main Menu
15. To print a report with the revised information select Reports NOTE You can store the final exercise report to the system or to an SD card You must define the type of final report you want stored to your system select System Setup gt Exercise Report gt Final Report The following menu items are available during the test end phase of the test Edit Press during the recovery or test end phase to allow you to enter or edit patient data reason for test termination or comments Reports Reestablish the median complex set the J point and select the three leads used to calculate heart rate Leads Select the leads used for Rhythm Lead 1 2 and 3 All Leads Lead Check or Lead Placement Median Select a lead to act as the median lead This can be a fixed lead scanned for lead with most ST depression Writer Change the writer s arrhythmia documentation doc cubic spline baseline control paper speed gain filter and writer on off settings Select to see More menu options Return to the system Main Menu New Patient Remain in the exercise application and start a test for a new patient 82 MAC 5500 MAC 5500 HD 2046275 016A Editing Protocols Protocols are scripts used to run exercise stress tests The Exercise Stress Test option comes with several predefined protocols The Edit Protocol function allows you to edit the predefined protocols or create new ones This chapter describes the protocol fields that
16. oy ss som v ey AA ya TT TT TT TT TT LX DN Reese Y TT 4 by 2 5s 3 rhythm Ids 140 MAC 5500 MAC 5500 HD 2046275 016A System Setup Unconfirmed Reports Formats cont d sacs __ eer CGR expanded Medion Y rhythm Ids sue forma vT TT TT swedish Forma v o Analog Outputs To configure the output signals sent to additional equipment connected to the system log on to the System Setup screen select ECG gt Analog Outputs and complete the fields described in the following table Analog Outputs Fast Analog Output Determines the lead signals sent to the device Options are Not used TTL Output Determines how the TTL output will be used Options are Not Used e QRS Detect Polarity Determines the polarity of the TTL Output Options are Positive Negative Width Defines the width of the TTL Output signal in milliseconds Enter a value from 4 to 48 1 These reports are available for both normal and abnormal ECGs 2046275 016A MAC 5500 MAC 5500 HD 141 System Setup Analog Outputs cont d Delay Defines the delay in milliseconds for the TTL Output QRS detector signal Enter a value from 0 to 100 QRS Beep Determines whether the system beeps for each QRS complex Select On to enable the beep CT Data Guard To configure the Clinical Trial Data Guard log on to the System Setup screen select ECG gt CT Data Guard Setup and com
17. Automatic documentation of arrhythmias with 2 5 seconds of raw data prior to the ectopic beat Leads of arrhythmia report correspond to leads on the screen Recall Report A delayed recording of raw data 10 seconds in duration Leads of recall report correspond to leads on the screen Median Report Based on exercise setups a Linked Median Medians amp Rhythms 6 or 12 Lead Comparative Medians amp Rhythm report will print See Additional Reports on page 182 for a description of these formats Exercise Final Reports The following formats are available for the final exercise report Summary Report One page overview of test with Resting and Max ST or peak median morphologies For Maximal ST Depression report only prints when a minimum of 5 mm of ST depression occurs in one of the following leads Il Ill aVF V2 V6 V1 aVR aVL excluded For elevation aVR is excluded Tabular Report Tabular summary of test by stage including time speed grade workload MET level heart rate blood pressure RPP and comments Selected Medians Records median morphologies at Baseline Maximum ST Depression Report Peak Exercise and Test End for 12 leads For Maximum ST medians the column only prints when a minimum of 5 mm of ST depression occurs in one of the following leads Il Ill aVF V2 V6 V1 aVR aVL excluded For elevation aVR is excluded Trends and Records a plot of the heart rate and blood pressure against
18. Display Screen View the waveform and text data Modem Port Connect to a telephone line 2046275 016A MAC 5500 MAC 5500 HD 33 System Overview qum O 3 LAN Port Connect to a LAN cable LEDs provide information about connection status The green LED indicates a good Ethernet link The amber LED flashes to indicate network traffic Back View O pe Bempem Internal View 34 MAC 5500 MAC 5500 HD 2046275 016A System Overview C Tune TT CS 1 Battery Supplies power when unit is not connected to AC power Recharge the battery when the battery icon flashes on screen Provides access to the writer paper tray and battery 3 Acquisition module Connects the unit to an acquisition module connector Paper tray Contains the paper used to print ECGs Paper size selector Adjusts the paper tray for STD US Letter or A4 paper sizes Back Panel WARNING CURRENT LEAKAGE Keep current leakage within acceptable limits when connecting auxiliary equipment to this device Total system current leakage must not exceed 100 microamperes qe eem Connects to an optional card reader bar code reader or PS 2 keyboard for entering patient information Connects to a GE KISS pump When using the exercise option connects to a T2000 treadmill or external blood pressure device NOTE Ergoline bicycle ergometers must be connected to both this port and the ANA TTL port 3 2 Connects to a local tran
19. For more information about reports refer to ECG Reports on page 135 A 2 3 Meat AE ieterval 118 m gls dation 63 ma wave al 294 373 ms 4 PR axes 72 64 56 BP 120 80mmHg pa ind Cheat paia Meds HCTZ ASA Cardizem Referred by Test Doctor SS 120456789 1D 123456789 j l 5 le 2L Y 9 8 7 6 48 MAC 5500 MAC 5500 HD 2046275 016A System Overview O CI CI Patient Demographics Displays information about the patient including patient name birth date gender race height weight room and location 2 Vital Signs Displays information about the patient s vital signs including heart rate PR interval QRS duration QT QTc P R T axes and blood pressure ECG Header Displays information about the ECG including patient ID ECG date and time and hospital name 4 Messages Displays system notifications including 12SL interpretation if enabled ACI TIPI information if enabled ACS information if enabled and critical value notifications if enabled Report Status Displays the status of the report and physicians HD Status Indicates whether high definition HD pacemaker detection mode was used HD mode is available only on reports generated by a MAC5500 on which HD is enabled and for ECGs acquired with a CAM HD device It will not appear if HD was not enabled if the ECG was not acquired with a CAM HD or if the report was generated on a MAC3500 12SL Version Displays the version of 1
20. NOTE Do not use the bar code reader for scanning the bar code that appears on the ECG printout The bar code on the ECG printout is a different format and not readable by the bar code reader Connecting the Bar Code Scanner Before you can use the bar code scanner it must be connected to the MAC system and the system must be configured to correctly use the peripheral Typically this is done only once and the scanner remains attached and ready for use 1 Connect the bar code scanner to port A on the back panel of the system For information on the system ports refer to Back Panel on page 35 Configure the scanner For information refer to Setting Up a Bar Code Reader on page 158 Scanning the Bar Code After the scanner has been set up use the following procedure to scan the bar code 1 66 For each new patient select Patient Data The message Scan the bar code opens Scan the bar code What happens next depends on your system settings The system may be set up to simply load the patient dota directly from the bar code Or it may be set up to use either the bar code s Patient ID or Visit Number to retrieve orders or ADT data Orders may be retrieved from the local cart or from the MUSE system while ADT information is always retrieved from the MUSE system With this variety of options several configuration combinations are possible However even with all the potential configurations only five responses are p
21. When you are done configuring your settings select Return at the bottom of the window This saves your settings to local memory and returns you to the Critical Values Setup menu Insert the SD card if necessary 4 Select Save to SD Card and press Return The settings are saved to the card 5 Eject the card and save it in a safe location or use it to configure other devices Restoring Critical Values from SD Card Use the following procedure to restore your critical value notification settings from an external SD card You can use this procedure to restore the notification settings in the case of a system failure You can also use it to quickly configure other systems 1 Insertthe SD card with your critical value notification settings Refer to Saving Critical Values to SD Card on page 145 for details and backing up your settings to an SD card 2 From the Main Menu select System Setup gt ECGs gt Critical Values Setup gt Restore from SD Card The settings on the SD card overwrite any settings on the device 3 Eject the card and save it in a safe location or use it to configure other devices 2046275 016A MAC 5500 MAC 5500 HD 145 System Setup Setting Up Signal Averaged ECGs To configure how the system calculates signal averages ECGs log on to the System Setup screen select Hi Res and complete the fields described in the following table NOTE These settings are available only if you have purchased
22. on page 170 Connect the system to an AC wall outlet to charge the battery Refer to Battery Maintenance on page dfe Connect the system to an AC wall outlet to charge the battery Refer to Battery Maintenance on page 172 Power up the unit Adjust the Automatic Shutdown settings if necessary Refer to Chapter 14 System Setup Reconnect the electrode s Refer to Chapter 3 Preparing the Patient Connect the modem to a telephone line and retry or move back into range Relocate the system to within range of an access point and retry transmission Verify that the LAN cable is connected to the LAN port and the Link LED Green lights up and Activity LED Yellow blinks 179 Troubleshooting Problem Cannot use the system because Device Password does not work You are prompted to format to recover the file system 180 Device Password has been changed or has not been adequately communicated to the staff The internal storage has been corrupted MAC 5500 MAC 5500 HD Contact your administrator for the Device Password Format the internal storage to restore the file system NOTE System recovery from internal storage corruption will destroy all ECG records in the system s internal memory 2046275 016A Report Formats The MAC system provides several report formats to provide the information you need to analyze and evaluate the patient s ECG The following sections des
23. oooccoccccccncncncncocococncoconononcncnrnrononons 118 Setting Up Signal Averaged ECG Report Printing ooooococcccoccccncoccncoccnnccoss 118 Setting Up ACI TIPI Interpretation 0c c cece KK k 118 Setting Up System BASICS erica 119 Miscellaneous Setup tao idas Sein eek 119 Patient QUESTIONS ig ven cha ceed o lid 121 ero RM HI 124 TWONSIMISSION sos itus nenn On UNE DO DD tra ded eec re torpedo E H ad rre 124 Network Settiligss sei ete E ed e te e ee ed debe eei des 126 OPUONACUVOLION dir RHET 126 Date GIN TIMEN ge a Cbd td 128 Largudge AEE RR I Ide rM TUN ertet 128 Power Up ODUOL S seite eet ote ee Eo ee l ke er Np de odo d e ONDE DR 129 Order Manager Interfaces Mulk kik eterne cete vedios diee Poe a e EOD eed eds 129 Input Methiod cose oc ib p D P bere be a Eee rA EENES 130 piden ik 131 ECG ACqUISILOD s o odo esp eot ie hr doeet eoa est a e d eae S 131 ESAS a ide 133 Patient Q estions eenaa e a osas 134 Whiter SetU ILE ITEM 135 ECO ROS a RO ERR PERSE 135 Analog OUTPUTS visito bli 141 CI Bata GUANA s s evadat s bee sende si beh ved vo cade nia tobe 142 Gritical Val es Setup 4 5 dae esee teet os rte ERE tah Mande ehe ete 143 Setting Up Signal Averaged ECGS Er kerek ke e k k kek k k K 146 Setting Up Exercise Tests sees kisseka ke kas edene kas k d e kek k e Ku k da 146 Miscellaneous Setup it cie Wi k ber d lal
24. 14 15 16 Editing Protocols When you are done editing the stages of the Pretest phase press Phase gt Exercise This opens the Exercise phase window Press the Stages Manual function key to toggle between the Stages and Manual modes of the phase as appropriate With the Stages mode selected repeat step 5 to edit the stages of the Exercise phase When you are done editing the stages of the Exercise phase press Phase gt Recovery This opens the Recovery phase window Repeat step 5 to edit the stages of the Recovery phase When you are done editing the stages of the Recovery phase press Phase gt Test End This opens the Test End phase window Select the report type to print during the Test End phase of the test Test End has only one stage and Report Type is the only parameter you can modify during the phase You have two options No Report or Final When done press Menu This opens a menu with the following options e Return Edit protocol phase names Save current protocol Print current protocol Edit different protocol e Erase current protocol e Restore default protocol Copy All to SD Card e Restore All from SD Card Main Menu Select Save current protocol to save your new or revised protocol Press Menu to open the Edit menu Do one of the following To add or modify another protocol press Edit different protocol and repeat from step 2 e To return to the main menu press Main
25. 2014785 001 Silver TRACE ECG Electrodes Window P50TR clear tape round solid gel 7 strip 350 box 2014786 001 SilverTRACE ECG Electrodes First Carbon P28MOC foam rectangle wet gel carbon snap 30 pouch 300 box 2046545 001 ECG Electrode Wet Gel P28 MOC SilverTRACE Electrodes 30 pack 402207 210 BabyMAC Electrodes Resting ECG Electrodes 10 card 50 pack 500 case 5608 003 GE Gray Suction Bulb 900703 205 Silver TRACE Ag AgCl Electrodes Adult Holter Stress Electrode Foam Oval Wet Gel 5 pkg 150 box 600 case 900703 230 Silver TRACE Ag AgCl Electrodes Adult Holter Stress Electrode Foam Oval Wet Gel 30 pouch 300 case 9033 015 GE Suction Electrode amp Gray Bulb 9623 003 Silver Mactrode Resting ECG Electrodes 10 card 100 pack 1000 case 9623 003P Silver Mactrode Plus Resting ECG Electrodes 10 card 100 pack 1000 case 9623 103P Silver Mactrode Plus Resting ECG Electrodes 14 card 140 pack 1400 case The following leadwires have been approved for use with this device Leadwires Leadwires 2001925 003 CAM 14 ECG Leadwire Universal 40 in 102 cm 2001925 004 CAM 14 ECG Leadwire Universal 51 in 130 cm 2046275 016A MAC 5500 MAC 5500 HD 11 Introduction Leadwires cont d CAM i i CAM i i CAM i i CAM i CAM AM Part Number 2001925 005 2001925 006 2016032 001 2016032 002 2016033 001 2016033 002 2020558 001 2020558 002 2020558 003 2020558 004 2020558 005 2020558 006 202
26. 5500 MAC 5500 HD 89 Printing ECG Reports Storing Printouts 90 When imaged and stored properly ECG tracings will resist fading for several years The expected lifespan depends on the paper For example GE Healthcare s Premium Thermal Recording Papers resist fading for 5 7 years By contrast GE Healthcare s Ultra Archivst Thermal Recording Papers are guaranteed to resist fading for 100 years Refer to the documentation that accompanies your paper for its expected lifespan To ensure the tracing is imaged properly the equipment must be maintained in accordance with its service manuals and technical memoranda To ensure the tracing lasts for the paper s expected lifespan observe the following precautions when storing your printouts e Store in a cool dark and dry location Temperature must be lt 80 F 27 C Relative humidity must be lt 65 e Avoid exposure to bright light or UV sources Sources of ultraviolet light include sunlight fluorescent lights halogen lights mercury vapor lamps and germicidal lamps Avoid contact with cleaning fluids and solvents Solvents to avoid include alcohols ketones esters ether and so forth Store thermal paper separately in manilla folders or polyester or polyimide protectors Plastic document protectors envelopes or sheet separators made of polystyrene polypropylene or polyethylene will not degrade thermal traces in themselves However these materials afford no prot
27. Enter or Return key on the keyboard Do not type Enter gt The greater than symbol or right angle bracket is a concise method to indicate a sequence of menu selections For example the statement From the main menu select System gt Setup gt Options to open the Option Activation window replaces the following From the main menu select System to open the System menu From the System menu select Setup to open the Setup menu From the Setup menu select Options to open the Option Activation window Illustrations All illustrations in the manual are provided as examples only Depending on system configuration screens that appear in the manual may differ from the screens as they appear on your system All patient names and data are fictitious Any similarity to actual persons is coincidental Notes Notes provide application tips or additional information that while useful are not essential to the correct operation of the product They are called out from the body text through a flag word and indentation as follows NOTE The tip or additional information appears indented below the NOTE flag word Related Documentation The following documents are referenced in this manual and provide additional information that may be helpful in the installation configuration maintenance and use of this product 2036070 006 Marquette 12SL ECG Analysis Program Physician s Guide 2046275 017 MAC 5500 MAC 5500
28. Entering Orders The MAC system offers two methods for entering orders This section describes both methods for entering orders and provides instructions for selecting and completing orders on the system Receiving Orders from a MUSE CV System Option The MUSE CV System can communicate orders to this system in the following ways SD card This is only available with MUSE v005D or later Modem This method works with both internal and external modems Local area network The MAC system must be connected to the LAN through the communications port on the right side of the MAC system Direct serial connection The MAC system and MUSE system can be connected using a standard serial cable Infrared MAC 5500 MAC 5500 HD 67 Entering Patient Information The MUSE system s infrared device must be pointed directly at the MAC system s IR port with no obstruction as shown in the following illustration 1 3 ft 30 4 91 4 cm 0 020 ED Wireless This method works with MobileLink and MobileLink UHS wireless systems For instructions on mounting configuring and connecting the client bridge to the system refer to the MobileLink Installation and Troubleshooting Guide NOTE Performance of the MobileLink wireless system may vary due to changes in RF radio frequency properties of your site or environmental conditions If you are experiencing intermittent connectivity in certain areas of your facility reinitiate the p
29. HD Resting ECG Analysis System Field Service Manual 2020299 021 MobileLink Wireless Communications Installation Manual 2025521 001 KISS Multilead Operator s Manual 2020299 025 LAN Option for MAC Resting ECG Systems Installation and Troubleshooting Guide Training This manual is intended as a supplement to not a substitute for thorough product training If you have not received training on the use of the device you should request training assistance from GE Healthcare 2046275 016A MAC 5500 MAC 5500 HD 31 32 Introduction To see available training go to the GE Healthcare training website http www gehealthcare com usen education index html and select Diagnostic Cardiology under the Technical Service Education section For more self paced course offerings tools and reference guides you may find useful please visit the GE Healthcare Education Store at www gehealthcare com educationstore MAC 5500 MAC 5500 HD 2046275 016A System Overview This chapter describes the device s hardware components software screen components report layout and basic navigation and data entry Familiarize yourself with this information before using the device Hardware Description This section identifies the key components of the MAC system hardware Familiarize yourself with these components their location and their use before attempting to use the equipment Front View wm Tse
30. Report 12 Rhythm Leads Autorhythm CGR Expanded Median Linked Median Medians and Rhythm 6 Lead Comparative Medians and Rhythm 12 Lead Comparative Medians and Rhythm Hi Res or PHi Res Signal Averaged Template Hi Res or PHi Res Signal Averaged Standard Hi Res or PHi Res Signal Averaged Expanded 10 seconds of 12 lead rhythm 10 seconds of 3 6 or 12 leads of rhythm One median complex for each of the 12 leads combined with 10 seconds of 3 lead rhythm Doubles the speed and gain of the median complex A4x 2 5 with 1 rhythm lead format The rhythm lead printed across the bottom of the report is the first lead of the Swedish format rhythm leads group that is configured in Exercise Setups Report Leads A median complex for each of the standard 12 leads is displayed in the upper portion of this report Below the medians are three rhythm strips These rhythm leads are the first three leads of the Swedish format rhythm leads group that is configured in Exercise Setups Report Leads The baseline and current medians are compared side by side and followed by real time waveforms The 6 leads used by this report are the Swedish format rhythm leads group that is configured in Exercise Setups Report Leads A one page report for which the baseline and current medians are compared side by side and followed by 2 5 seconds of real time rhythm for the standard 12 leads ST level and ST slope are reported
31. There are three possible settings e Never The system will not prompt the user when the signal quality is poor However the statement Poor data quality interpretation may be adversely affected will print on reports for red lead quality situations Yellow The system will prompt the user for both red and yellow signal quality situations The user can then choose to continue or cancel the ECG The statement Poor data quality interpretation may be adversely affected will print on reports Red The default value the system will prompt the user for red signal quality situations The user can then choose to continue or cancel the ECG The statement Poor data quality interpretation may be adversely affected will print on reports NOTE If Hookup Advisor and Preview before analysis are both on this setting is disregarded because any lead quality message will be displayed when the user is prompted to continue in the preview screen The generation of the statement Poor data quality interpretation may be adversely affected is based on the Hookup Advisor quality level as previously described even if Hookup Advisor is not turned on If Hookup Advisor is not turned on the statement will be generated based on what the Hookup Advisor level would have been had it been enabled Pre acquisition Determines whether the system begins to acquire ECG data as soon as the leadwires are connected to a patient If set to Yes the system does not wait for
32. a rhythm lead the new lead prints on all reports that include the lead For example if you select V5 for the Swedish format rhythm lead 1 then the V5 waveform prints on all reports that include Swedish format rhythm lead 1 When printing or storing 3 lead median or trend reports the first three Swedish format rhythm leads are used When printing or storing 6 lead median reports all six of the Swedish format rhythm leads are used 136 MAC 5500 MAC 5500 HD 2046275 016A System Setup Extra Leads In addition to the report leads the 15 Lead ECG Report also allows you to define the leads used by three additional electrodes To configure the extra leads log on to the System Setup gt ECG gt 15 Lead Reports gt Extra Leads Extra Leads Lead Set Determines the three additional leads used for 15 lead reports You can Select a predefined set of leads Right Precordial V4r V5r Ver Posterior V7 V8 V9 NEHB D A J Mixed 3 V4r V8 V9 Select Custom 3 to define electrode positions for A1 A2 and A3 Vector Loops In addition to the report leads the Vector Loops Report also allows you to configure the vector loops To configure the vector loops log on to System Setup gt ECG gt Vector Loops ECG Reports gt Vector Loops Vector Loops Number of copies Determines the number of report copies that print Enter a value from 0 to 10 Main loop gain Select a default value for the main loop gain in
33. also use this feature to quickly configure other MAC systems To restore your system settings do the following 1 From the Main Menu select System Setup gt Restore Setup 2 Do one of the following e To restore the default settings select To Original Factory Settings e To restore your custom settings select From SD Card 160 MAC 5500 MAC 5500 HD 2046275 016A System Setup An SD card with the system settings must be inserted into the device s card slot To cancel the restore select Do Not Restore Setup 2046275 016A MAC 5500 MAC 5500 HD 161 System Setup 162 MAC 5500 MAC 5500 HD 2046275 016A Maintenance Regular maintenance irrespective of usage is essential to ensure that the equipment will be functional when required For the MAC system regular maintenance includes the following Equipment Inspection and Cleaning e Paper Maintenance Battery Maintenance Leadwire Adapter Replacement For the maintenance procedures for your peripheral equipment refer to the documentation provided with that equipment WARNING MAINTENANCE Failure on the part of all responsible individuals hospitals or institutions employing the use of this device to implement the recommended maintenance schedule may cause equipment failure and possible health hazards The manufacturer does not in any manner assume the responsibility for performing the recommended maintenance schedule unless an Equipment Maintenanc
34. analysis for the current ECG MAC 5500 MAC 5500 HD 97 Receiving ECGs e Rhythm displays rhythm information for the current ECG Next displays the next selected ECG e Return closes the display and returns to the list of ECGs e To print the selected ECG s press Print The system retrieves and prints the test s The report format set up in System Setup is used Refer to Chapter 14 System Setup for more information 98 MAC 5500 MAC 5500 HD 2046275 016A Editing ECGs Editing 2046275 016A While it usually not necessary to modify an ECG the MAC system allows you to edit an ECG s demographic information ECG measurements and interpretive statements After you have edited the ECG you are prompted to save the updated file NOTE If you plan to store ECGs in XML format see Transmitting ECGs in XML Format on page 94 DO NOT edit the ECGs on the MAC system Edits made to ECGs WILL NOT BE SAVED in the XML fille Demographic Information Anyone can edit an ECG s demographic information This includes the patient information medications test information and the ACI TIPI chest or left arm pain data This allows anyone to correct or update the information as necessary 1 Press File Manager A list of ECG reports opens 2 Press Select The cursor appears on the screen Highlight the ECG report to edit 4 Press Edit to open a list of editing options 5 Select one of the following options e Patient In
35. any lead ST Depression z 0 05mV ST Elevation 2 0 1mV T wave change 2 0 5mV Negative This is assessed if neither the Positive nor Borderline criteria are met To following formulas are used to calculate the values in the previous criteria ST depression rest ST post J post exercise ST post J ST depression rest ST post J post exercise ST post J T wave change absolute value of rest T wave amplitude post exercise T wave amplitude ST post J amplitude at the post J point When the assessment is positive or borderline the lead with the largest change prints MAC 5500 MAC 5500 HD 2046275 016A Creating Bar Codes and Magnetic Cards The following sections provide the information you need to configure bar codes and magnetic patient ID cards The bar code reader can read Code 39 39EX 128 PDF 417 2 D Interleaved Code 2 of 5 and Data Matrix bar codes The card reader can read magnetic cards that adhere to ISO 7810 and 7811 NOTE All data resides in fixed width fields The bar code or card generator must be programmed to add trailing spaces after fields shorter than the fixed length of the fields being used by your system Manual Reader Configuration 2046275 016A The following table identifies the available fields for configuring your magnetic card reader and bar code reader Refer to Setting Up a Card Reader on page 156 and Setting Up a Bar Code Reader on
36. before requesting service from GE Healthcare or its authorized representatives Service Requirements Failure on the part of the responsible individual hospital or institution using this equipment to implement a satisfactory maintenance schedule may cause undue equipment failure and possible safety hazards Regular maintenance irrespective of usage is essential to ensure that the components of this system are always functional when required Additional Assistance GE Healthcare maintains a trained staff of application and technical experts to answer questions and respond to issues and problems that may arise during the installation maintenance and use of this product Contact your local GE Healthcare representative to request additional assistance 2046275 016A MAC 5500 MAC 5500 HD 29 Introduction Manual Information This section provides information for the correct use of this manual Manual Purpose This manual provides information necessary for the configuration and safe operation of this equipment in accordance with its function and intended use It is not intended as a replacement for but a supplement to thorough product training Keep it with the equipment at all times Additional manuals may be ordered by contacting GE Healthcare Refer to the service manual for technical information related to the maintenance and repair of the equipment Intended Audience This manual is intended to be used by the person
37. between Recording post exercise ECGs Post Exercise ECG Defines the time in minutes after the first post exercise ECG when Time an additional ECG should be taken You can take up to nine ECGs Set any undesired tests to 0 Managing System Setup This section describes how to do the following Print System Setup e Save System Setup e Restore System Setup Printing System Setup To print your system settings for future reference select System Setup gt Print Setup Place the printout in a secure location in case you need to manually restore the settings at a later date Saving System Setup To save the changes you make to your system settings select System Setup gt Save Setup You can choose to save the settings to local memory or to an SD card After saving your changes to local memory you should also save the settings to an SD card for use in restoring your settings at a later date You can also use a saved configuration to quickly configure subsequent systems NOTE Saving the system setup to an SD card does NOT save your Critical Values configuration You must manually save the Critical Values configuration Refer to Saving Critical Values to SD Card on page 145 for more information Restoring System Setup Restore Setup allows you to revert your settings You can use this option to return to the default factory settings or to restore custom settings that were saved to an SD card If using an SD card you can
38. can be modified and explains how to modify them For information on conducting stress tests refer to Chapter 6 Exercise Stress Testing Protocol Overview A protocol controls the duration and intensity of an exercise stress test If used with supported exercise equipment the protocol can automatically adjust the equipment with unsupported equipment the protocol can alert the tester to manually adjust the equipment You can modify the following protocol fields Protocol Parameters Protocol Name Displays the name of the protocol you are editing Pet sete A Exercise Test Type Determines which exercise equipment will be used during the test and consequently the type of test to conduct Valid values are e Treadmill in MPH or Km h Select this option for digital treadmills that can connect to and be controlled by the MAC system You would select this option if you are using GE Healthcare s T2000 treadmill e Analog Treadmill in MPH or Km h Select this option for analog treadmills that cannot be connected to the MAC system If this option is selected the MAC system will alert the operator to manually adjust the treadmill at the appropriate points in the test Ergometer in Watts or KPM Select this option for digital ergometers that can connect to and be controlled by the MAC system 2046275 016A MAC 5500 MAC 5500 HD 83 Editing Protocols Protocol Parameters cont d 84 Ramp Protocol Determines how fr
39. data via patient card reader Edit Protocol EDPR Allows you to edit stress test protocols CT Data Guard CTDG Enables the clinical trial and data guard features Ethernet LAN ELAN Enables you to connect to an Ethernet local area network HD HDMD Enables the high definition pacemaker detection Pacemaker function Requires the use of the CAM HD acquisition Detection module MAC 5500 MAC 5500 HD 127 System Setup Critical Values Enables the critical value function which allows you to define custom alerts based on key ECG values If the Critical Values function is enabled you must configure the alerts Refer to Critical Values Setup on page 143 for more information Acute Enables the acute coronary syndrome ACS function Coronary This function performs an ACS analysis on resting Syndrome ECGs vector loops ECGs and 15 lead ECGs 3 Type the 12 digit activation code you received when you purchased the option and press Return If you enter a valid option code an asterisk will be displayed next to the option in the list indicating it is now active 4 Repeat for each option you purchased 5 When you are done select Return Date and Time To configure the system s date and time log on to the System Setup screen select Basic System Date and Time and complete the fields described in the following table Date and Time Configuration Current date Select the current date month and year
40. depending on the current lead quality level and the MAC 5500 MAC 5500 HD 2046275 016A 2046275 016A Recording an ECG Prompt level in the system setup If a message and prompt is displayed the lead quality indicator will reflect the overall 10 second lead quality If Preview before analysis is enabled the system setup Prompt level is disregarded and the system immediately displays the Preview screen Any lead quality messages will be displayed in this screen along with the overall 10 second lead quality indicator In either case users may then do either of the following Select Continue to continue print the ECG e Select Cancel to cancel Standard ECGs Use the following method for resting pediatric vector loop and 15 lead ECGs 1 After preparing the patient select the correct ECG softkey To conduct a resting ECG press Resting ECG To conduct a pediatric ECG press Pediatric ECG To conduct a vector loops ECG press Vector Loops e To conduct a 15 lead ECG press 15 lead ECG The appropriate ECG test window opens NOTE All options may not be available depending on system configuration Enter the correct patient information Refer to Chapter 4 Entering Patient Information for details Adjust the ECG settings as appropriate To select a different set of leads press Leads A list of available leads opens All leads selects all the available leads V1 II V5 selects the i
41. e 25 250Hz e 40 250Hz e 80 250Hz Averaging Target Selects the item to use for averaging the Hi Res results Options are Beat Count e Noise Level Target Beat Count Determines the target beat if Beat Count is selected as the Averaging Taget Enter the target number of beats per minutes Target Noise Level Determines the target noise level if Noise Level is selected as the Averaging Taget Enter the target noise level in microVolts MAC 5500 MAC 5500 HD 155 System Setup Hi Res Settings cont d Correlation Determines the correlation threshold Options are Threshold Medium High Very High Ultra High Template Format Determines how many copies of this report print for the Hi Res function Enter a value from O to 10 If you enter O the report will not print Standard Format Determines how many copies of this report print for the Hi Res function Enter a value from O to 10 If you enter O the report will not print Expanded Format Determines how many copies of this report print for the Hi Res function Enter a value from O to 10 If you enter O the report will not print Overlapped Format Determines how many copies of this report print for the Hi Res function Enter a value from O to 10 If you enter 0 the report will not print Prompt Allows you to define two custom patient questions when entering patient data for the Hi Res test Determines the type of response allowed for each custom patient question
42. field 5 When you are done press Return 118 MAC 5500 MAC 5500 HD 2046275 016A System Setup Setting Up System Basics This section describes the following basic system settings e Miscellaneous Setup e Patient Questions e Screen Colors e Transmission Network Setup Option Activation Date and Time e Language Order Manager Interface e Input Method Select Miscellaneous Setup To configure the system s basic settings log on to the System Setup screen select Basic System Miscellaneous Setup and complete the fields described in the following table Miscellaneous Setup Institution name Enter the name of your hospital clinic and so on as you want it to print on reports On most reports the institution name prints at the top Text entry Determines how text will be entered in the system Select Uppercase only to type text in uppercase letters Select Upper and lowercase to type text in upper and lowercase letters Speaker volume Determines how loud the system speaker will be e Select Low to set the system s speaker to low volume Select High to set the system s speaker to high volume External video port To use an external monitor with the system select one of the following options e Select Option 1 for most remote monitors e Select Option 2 if your monitor does not work with Option 1 Information line Determines whether additional help will be displayed on the screen Select Yes
43. for each lead Hi Res or PHi Res Signal Averaged Template Vector magnitudes of X Y Z 400mm s of expanded X Y Z medians and a RMS voltage function VM plot MAC 5500 MAC 5500 HD 2046275 016A Report Formats ACI TIPI The analysis of the acquired ECG data appears at the top of the report Hi Res or PHi Res XVZ data at two different amplitudes r Overlapped One median complex for each of the 12 leads combined with 10 seconds of 3 lead rhythm Swedish Format1 One median complex for each of the 12 leads at writer speed of 50mm s combined with 5 seconds of 6 lead rhythm at half writer speed Text is on the bottom of the page Swedish Format2 5 seconds for each of the 12 leads at writer speed 50mm s Text is on the top of the page 2 by 5s Displays and prints ECG data in a 2 x 5 second simultaneous format Simultaneous This report format allows you to enable Auto Gain and or Auto Shift features NOTE The Auto Shift feature automatically shifts the waveforms vertically to avoid or minimize waveform overlap between rows If enabled this feature affects only the printed 2x5 second report The Auto Gain feature adjusts the gain to minimize waveform overlap Depending on the amount of overlap the Auto Gain may be applied to all leads or only the chest leads If enabled this feature affects the printed 2x5 second report If both Auto Shift and Auto Gain are selected the 2x5 second printed report will be a 2 or a
44. from O to 10 If you enter 0 the report will not print Interpretation Available for each report format except the Expanded Median without report this field determines how many copies of the report without 12SL interpretation will print You can enter any value from 0 to 10 If you enter 0 the report will not print Tic marks Available only for the Expanded Median report this field determines whether tic marks will print on the report Select Yes to include tic marks Medians times 2 Available only for the Expanded Median report this field determines whether the medians will be doubled Select Yes to double the medians Auto gain Available only for the 2 by 5s Simult report this field determines whether the report will apply the auto gain filter Select Yes to apply the auto gain filter Auto shift Available only for the 2 by 5s Simult report this field determines whether the report will apply the auto shift filter Select Yes to apply the auto shift filter The following table lists the available formats for confirmed ECGs and identifies the type of ECG for which each format is available Confirmed Reports Formats Bex TT TT TT TU o To o 29y 5 xm yT TT TT asm vT TT id z Y TT 138 MAC 5500 MAC 5500 HD 2046275 016A System Setup Confirmed Reports Formats cont d Formats 15 Lead Vector Loops 4 by 2 5s 1 rhythm Id 4 by 2 5s 3 rhythm Ids 2046275 016A 5 by 2s 1 rhythm Id 5 by 2s 3 rh
45. leads to define which three leads in a three lead Rhythm report print Select 6 leads to define which six leads in a six lead Rhythm report print Select All leads to display and print 10 seconds of data for 12 or 15 leads Select Lead Check to display and print real time data for each of the 12 or 15 leads Select Lead Placement to display and print real time data for each of the 12 or 15 leads and to display the chest electrode placement Autorhythm Determines the group of rhythm leads to print on the Autorhythm report RMR CGR extra Determines the rhythm lead s to print on the RMR and CGR reports rhythm leads When you change a rhythm lead the new lead will print on all reports that include the lead For example if you select V5 for RMR CGR extra rhythm lead 1 then the V5 waveform will print on all reports that include RMR CGR extra rhythm lead 1 2046275 016A MAC 5500 MAC 5500 HD 149 System Setup Report Leads cont d Swedish format Sets the rhythm lead s to print in the Swedish Format reports rhythm leads When you change a rhythm lead the new lead will print on all reports that include the lead For example if you select V5 for the Swedish format rhythm lead 1 then the V5 waveform will print on all reports that include Swedish format rhythm lead 1 When printing or storing 3 lead median or trend reports the first three Swedish format rhythm leads are used When printing or storing 6 lead median
46. leads used to calculate heart rate Leads Select the leads used for 3 or 6 Rhythm leads All Leads Lead Check or Lead Placement Median Select a lead to act as the median lead This can be a fixed lead or scanned for lead with most ST depression Writer Change the writer s arrhythmia documentation doc cubic spline baseline control paper speed gain filter and writer on off settings 80 MAC 5500 MAC 5500 HD 2046275 016A Exercise Stress Testing Recovery Phase In recovery the treadmill speed and grade or the ergometer load decreases based on the protocol configuration 1 Press the Recovery button to advance to the recovery phase The clock begins timing the recovery phase A maximum 12 lead measurement is taken if that is part of the selected protocol 2 f necessary adjust the equipment s speed grade or load manually You can adjust the speed grade or load in the following ways However once you press these keys the pre programmed protocol becomes inactive you must manually control the speed and grade during the remainder of the exercise and recovery phases Press Speed W to increase speed within 5 seconds of your last workload change e Press Speed W to decrease speed within 5 seconds of your last workload change e Press Grade to increase grade within 5 seconds of your last workload change e Press Grade to decrease grade within 5 seconds of your last workload change
47. lec E 42 M in MSTnu cuero p et peste A edes oa rt deve eges a is 45 Report Layout yal tano HH HHHH HH HHHH N 48 Hall ST al j oj Datd s se ede FUP NEES e ET a a 50 Preparing the Patient Preparing the Patient s Ski n L erkek erkek ke ek k ke nooo 54 Electrode Placement cccccccccesssscsssesececcceccescesssccesecsccesseescascssessseseees 55 Resting ECG Placement 2 n ere A E a 55 Exercise ECO POC Meana arar et Rr pO RERO Eee rne EI aga Pe elsa 60 Entering Patient Information Manually Entering Patient Informdtion eke ke 64 Reading a Patient Card Option cessere 64 Connecting the Card Redder ceo ce petet eter trea e gate l 65 Reading q PatientiD Cards io techo rre di Tee ec a et DI K ed GER 65 Scanning a Bar Code Option ooooocoonoconcccnnonocanononancnnoononcncnonnccnnooo 66 Connecting the Bar Code Scahrier cs raza 66 Seanningthe Bar Edecanes Maure le buta 66 Entering Orders i iisau ls cc kak k da 67 Receiving Orders from a MUSE CV System Option sss 67 Manually Entering Orders sss citada A RREN 69 Selecting and Completing Orders 3 eem tree ttt eb k ne n kU n n 69 Recording an ECG Hookup AGVISOE iii Sone rik id 71 Standard ECGS D c 73 Signal Averaged ECGS orita ceo a ee k sa ee toes a e kk dayan br d s aker 75 Masters Step ECGS decisores le arto ii tii 76 Exercise Stress Testi
48. of data revealing an individual s racial origin is subject to legal requirements such as obtaining the patient s prior consent If you elect to collect this type of data it is your responsibility to ensure that you comply with all applicable legal requirements If the optional Clinical Trial Data feature is enabled do one of the following e fthe patient is part of a clinical trial select Yes in the Clinical Trial Data field at the bottom of the Patient Data window A pop up window opens Enter the clinical trial information as appropriate e If the patient is not part of a clinical trial select No in the Clinical Trial Data field at the bottom of the Patient Data window See CT Data Guard on page 142 for information on enabling the Clinical Trial Data feature Select Return to save the patient data and return to the ECG window You can now begin the ECG test Reading a Patient Card Option If the system includes the option to read a patient ID or visit card depending on configuration you can enter patient information by sliding the patient s magnetic card through the card reader This section provides instructions for connecting and using the card reader 64 MAC 5500 MAC 5500 HD 2046275 016A Entering Patient Information Connecting the Card Reader Before you can use the card reader it must be connected to the MAC system and the system must be configured to correctly use the peripheral Typically this is done on
49. serial port or infrared port e To use the infrared port select Yes To use the serial port select No Serial line baud rate Determines the speed to transmit data on the serial port Default Location Determines the method and device to which ECGs are automatically transmitted Select one of the following values To transmit by local infrared communication or by local cable select Serial line MUSE To transmit ASCII data to the serial port select Serial line ASCII out To transmit XML data to the serial port select Serial line XML out e To transmit by LAN select Ethernet MUSE NOTE Infrared communication is not available on MAC 5500 HD systems If transmitting ASCII or XML data the PC that receives XML data through the serial line must be running a terminal emulator program for example HyperTerminal 2046275 016A MAC 5500 MAC 5500 HD 125 System Setup Network Settings To configure the system s local area network settings log on to the System Setup screen select Basic System gt Network Setup and complete the fields described in the following table Network Settings IP Address Identifies the network s IP address Subnet Mask Identifies the network s subnet mask Identifies the network s gateway Port Number Identifies the network s port number Option Activation Use the following procedure to activate system options 1 Log into the System Setup function Refer to
50. settings for exercise reports Exercise Reports Settings Exercise Reports Determines which format will be used for each exercise report Refer to the following table for a list of the available formats Median Report Determines which format will be used for each median report Options are e Linked Medians Medians Rhythm e 6 Lead Comparative Medians Rhythm e 12 Lead Comparative Medians amp Rhythm The following table lists the available report formats Exercise Reports Formats TT cD i i p E EPIRI Final Report The Final Report settings allow you to configure the following values e storage option format of the final report preview format of the medians to include which reports to include in the final report 2046275 016A MAC 5500 MAC 5500 HD 151 System Setup To configure the final report select System Setup gt Exercise Test gt Final Report and complete the fields in the following table Final Report Storage Option Selects the method for storing the final report Options are Store Strips and Final Report Store Final Report Only e No storage of test data Final Report Preview Selects the format of the final report preview Options are No preview report e Summary report e Tabular report Selected median e Trend amp Medians Median report e Trend report Summary Report Determines how many copies of the report will print Enter a value from O
51. the Patient Data window Accept or modify the data as needed e If the system locates only one ADT record it loads that record and displays it in the Patient Data window Accept or modify the data as needed e If the system locates multiple matching ADT records it displays a list of those records Do one of the following Select the correct record to load its ADT information You can then use or modify the patient information as needed Select Cancel to load the patient information directly from the card You can then use or modify the patient information as needed e If the system locates one matching order it retrieves that order You can then modify the order information or begin the test e Ifthe system locates multiple matching orders it displays a list of those orders MAC 5500 MAC 5500 HD 65 Entering Patient Information Do one of the following Select the correct order to load it You can then modify the order information or begin the test Select Cancel to load the patient information directly from the card You can then use or modify the patient information as needed For information on configuring your system refer to Appendix E Creating Bar Codes and Magnetic Cards Scanning a Bar Code Option If the system includes the option to scan a bar code you can enter patient information by scanning the bar code This section provides instructions for connecting and using the bar code scanner
52. the user to press ecg The latest 10 seconds of ECG data is ready for analysis when this setting is enabled 132 MAC 5500 MAC 5500 HD 2046275 016A ECG Analysis To configure the analysis of ECGs log on to the System Setup screen select ECG gt ECG Analysis and complete the fields described in the following table 2046275 016A ECG Analysis System Setup Preview before analysis Screening criteria Suppress NORMAL statement Suppress ABNORMAL and BORDERLINE statements Storage format Store XML format Determines whether the system will display the ECG data before it analyzes it Applies for resting pediatric 15 lead and vector loops only Select Yes to enable preview Prevents specific 12SL statements from appearing on ECG reports Refer to the 12SL Physician s Guide for more information on 12SL statements Prevents the Normal ECG 12SL analysis statement from appearing on printed stored and transmitted ECG reports Select Yes to suppress the NORMAL statement Prevents the Abnormal ECG and Borderline ECG 12SL statements from appearing on the printed stored and transmitted ECGs Select Yes to suppress the statement Determines the data compression format in which ECG data is stored on the MUSE CV system The appropriate value depends on the version of the MUSE CV system e 500Hz MUSE Network Select this option for systems running MUSE CV version 004A or later 500Hz DVS MUSE Network Selec
53. time Next Medians to these trend graphs are channels of stored median data from the various stages of an exercise test Median Report Records median morphologies for 3 6 or 12 leads The 3 and 6 lead reports are configured using the Swedish format rhythm leads of the Exercise Setups Report Leads The 12 lead report uses the standard 12 lead set The median storage intervals also referred to as sample cardiac cycles can be configured using the Median First and Repeat column of the Protocol Editor Trend Reports Records plots of PVCs heart rate and blood pressure Also produces a trend report of ST level and slope vs time The 3 lead trend report will use the first three leads of the Swedish format rhythm leads ST HR Loops Report two dimensional representation of ST Level vs Heart Rate ST HR Slope Report Records linear regression of heart rate adjusted slope for all leads plus median morphology of the lead with the highest slope 184 MAC 5500 MAC 5500 HD 2046275 016A Report Formats Exercise Report Codes 2046275 016A The following report codes are printed in the lower left corner of the exercise reports so ETT MAC 5500 MAC 5500 HD 185 Report Formats 186 MAC 5500 MAC 5500 HD 2046275 016A Master s Step Data The following sections provide the information you need to run a Master s Step stress test NOTE The Master s Step is an option and is available only in Japan Maste
54. to 10 If you enter 0 the report will not print Medians The field below Summary Report selects the medians to include on the Summary report Options are Resting and Max ST Medians and Resting and Peak Medians Tabular Report Determines how many copies of the report will print Enter a value from O to 10 If you enter 0 the report will not print Selected Medians Determines how many copies of the report will print Enter a value from O to 10 If you enter 0 the report will not print Trend amp Medians Determines how many copies of the report will print Enter a value from O to 10 If you enter 0 the report will not print Median Report Determines how many copies of the report will print Enter a value Leads from O to 10 If you enter 0 the report will not print f you enter a number greater than 0 select the leads to include on the report Options are 3 6 and All Trend Report Leads Determines how many copies of the report will print Enter a value from 0 to 10 If you enter 0 the report will not print f you enter a number greater than 0 select the leads to include on the report Options are 3 and All ST HR Loops Determines how many copies of the report will print Enter a value from O to 10 If you enter 0 the report will not print ST HR Report Determines how many copies of the report will print Enter a value from O to 10 If you enter 0 the report will not print 152 MAC 5500 MAC 5500 HD 20462
55. to calculate the maximum and target heart rates New Protocol Select a different exercise test protocol This function is only available if the test will be printed only not stored to memory Measurements Reestablish the median complex set the J point and select the three leads used to calculate heart rate Leads Select the leads used for 3 or 6 Rhythm leads All Leads Lead Check or Lead Placement Median Select a lead to act as the median lead This can be a fixed lead or scanned for lead with most ST depression Writer Change the writer s arrhythmia documentation doc cubic spline baseline control paper speed gain filter and writer on off settings Exercise Phase 2046275 016A The selected protocol controls the treadmill or ergometer When you enter the exercise phase e the belt speed and grade or the ergometer workload changes according to the selected protocol e the exercise clock top starts and e the system starts to save the test data WARNING FALLING HAZARD Severe injury can result from a fall Patients should wait until the treadmill belt is moving before stepping onto the belt Step onto the belt with one foot at a time Avoid rapid changes in belt speed 1 Press the Exercise button to begin the exercise phase During the test you can manually perform operations from the function keyboard 2 Press the Start tmill button if the treadmill or ergometer has not been started yet If y
56. 00 HD 2046275 016A Maintenance Use the following procedure to charge the battery 1 Power off the system 2 Connect the system to an AC wall outlet To indicate the battery is charging the amber battery light glows 1 and the charging battery icon is displayed on the screen 2 3 Charge the system for 4 5 hours or until the battery gauge icon indicates a full charge NOTE If the battery is fully charged or exceeds safe charging temperature the system will not charge the battery Conditioning the Battery In addition to normal system use periodic deep discharge cycles may be required to ensure consistent battery performance A deep discharge cycle occurs when the battery is discharged until the system shuts down and then recharged until it is full GE Healthcare recommends one deep discharge cycle once every three months but does not recommend over exercising the battery with multiple deep discharge cycles Replacing the Battery No matter how well you maintain your battery you will eventually need to replace it Refer to the following illustration for instructions on how to replace the battery 2046275 016A MAC 5500 MAC 5500 HD 173 Maintenance WARNING BATTERY PACK DISPOSAL Do NOT dispose of the battery pack by fire or burning Follow local environmental guidelines concerning disposal and recycling WARNING CHEMICAL BURN If battery fluid contacts your skin eyes or clothing immediate
57. 046275 016A MAC 5500 MAC 5500 HD 117 System Setup Setting Up Automatic ECG Transmission Use the following procedure to set up the system to automatically transmit ECGs NOTE Before setting up automatic transmission you must define the receiving device its default location and its transmission paramters Refer to Transmission on page 124 1 Log into the System Setup function Refer to Process Overview on page 115 2 Select ECG gt ECG Analysis gt Auto ECG Transmission A list of options opens e All ECGs No ECGs e Only ABNORMAL ECGs 3 Select the desired option and press Return 4 When you are done press Return Setting Up Signal Averaged ECG Report Printing This option allows you to select the report format that will print for signal averaged ECGs 1 Log into the System Setup function Refer to Process Overview on page 115 2 Select Hi Res A list of available report formats is displayed 3 Select the type and quantity of formats to print When you are done press Return Setting Up ACI TIPI Interpretation Use the following procedure to set up the system to automatically prompt you for ACI TIPI information required for interpretation 1 Loginto the System Setup function Refer to Process Overview on page 115 2 Select ECG Select ECG Analysis Do one of the following To enable ACI TIPI select Yes in the Enable ACI TIPI field To disable ACI TIPI select No in the Enable ACI TIPI
58. 0558 007 2020558 008 2020558 009 2020558 010 2020558 011 2020558 012 2020558 013 2020558 014 2020558 015 2020558 016 2020558 017 14 ECG Leadwire Dedicated Banana AHA 26 in 66 cm V1 CAM 14 ECG Leadwire Dedicated Banana AHA 26 in 66 cm V2 CAM 14 ECG Leadwire Dedicated Banana AHA 26 in 66 cm V3 CAM 14 ECG Leadwire Dedicated Banana AHA 26 in 66 cm V4 CAM 14 ECG Dedicated Banana AHA 26 in 66 cm V5 CAM 14 ECG Leadwire Dedicated Banana AHA 26 in 66 cm V6 CAM 14 ECG Leadwire Dedicated Banana AHA 26 in 66 cm V3R CAM 14 ECG Dedicated Banana AHA 26 in 66 cm V4R CAM 14 ECG Leadwire Dedicated Banana AHA 26 in 66 cm V7 CAM 14 ECG Leadwire Dedicated Banana AHA 26 in 66 cm E CAM 14 ECG Dedicated Banana AHA 26 in 66 cm H CAM 14 ECG Leadwire Dedicated Banana AHA 26 in 66 cm CAM 14 ECG Leadwire Dedicated Banana AHA 26 in 66 cm M Leadwire Leadwire Leadwire 12 2020559 001 2020559 002 2020559 003 2020559 004 2020559 005 2020559 006 2020559 007 2020559 008 2020559 009 2020559 010 2020559 011 CAM 14 ECG CAM 14 ECG CAM 14 ECG CAM 14 ECG CAM 14 ECG CAM 14 ECG CAM 14 ECG CAM 14 ECG CAM 14 ECG CAM 14 ECG CAM 14 ECG Leadwire Leadwire Leadwire Leadwire Leadwire Leadwire Leadwire Leadwire Leadwire Leadwire Leadwire Dedicated Banana Dedicated Banana Dedicated Banana Dedicated Banana Dedicated Banana Dedicated Banana
59. 0V single phase circuit This equipment is suitable for connection to public mains as defined in CISPR 11 CAUTION SERVICEABLE PARTS This equipment contains no user serviceable parts Refer servicing to qualified service personnel CAUTION SUPERVISED USE This equipment is intended for use under the direct supervision of a licensed health care practioner MAC 5500 MAC 5500 HD 27 Introduction Classification This device is classified as follows in accordance with IEC 60601 1 Category Classification Type of protection against electric shock Class internally powered equipment Degree of protection against electric shock Type BF defibrillation proof applied part Degree of protection against harmful ingress Ordinary equipment enclosed equipment of water without protection against ingress of water Degree of safety of application in the Equipment not suitable fo use in the presence presence of a flammable anesthetic mixture of a flammable anesthetic mixture with air or with air or with oxygen or nitrous oxide with oxygen or nitrous oxide Method s of sterilization or disinfection Not applicable recommended by the manufacturer Mode of operation Continuous operation Underwriters Laboratories Inc o3 Medical Equipment s 1 MEDI pmen With respect to electric shock fire and mechanical hazards only in ULGOG01 1 CAN CSA 022 2 No 601 1 accordance with applicable UL standards EMI EMC Requiremen
60. 2SL used to analyze the ECG MAC version 10 uses 12SL version 22 and appears on the report as 12SL v241 E Model and Displays the product model MAC55 and software E Version version 010x Report Format Displays the title of the report Gain Setting Displays the gain setting of the ECG Refer to Standard ECGs on page 73 for more information on the gain setting Filter Setting Displays the filter setting of the ECG Refer to Standard ECGs on page 73 for more information on the filter setting Waveforms Displays the ECG waveforms The leads and waveforms printed depend on the leads selected when conducting the test Refer to Standard ECGs on page 73 for more information on the leads setting Clinical Trial Data Displays the clinical trial data gathered during the ECG test if the CT Data Guard option was activated and configured Refer to CT Data Guard on page 142 for more information Speed Settings Displays the speed setting of the ECG Refer to Standard ECGs on page 73 for more information on the speed setting 2046275 016A MAC 5500 MAC 5500 HD 49 System Overview Entering Data You have two methods for entering data into the MAC system Typing data into a highlighted field e Selecting data from a drop down list Typing Data into a Highlighted Field Last Name 1 Using the Arrow Pad press the arrow keys to highlight the desired field 2 Type the relevant data into th
61. 3 page report The first page will be in the 2x5 format with the default system gain and with Auto Shift applied In most cases if waveforms overlap on the first page the second page will be in the 2x5 format with Auto Shift and Auto Gain applied This page is only printed if the first page had waveform overlap The third page will be the 10 second rhythm strip for the first extra lead defined in the resting ECG lead setup with the default gain Select Yes for Auto Gain and or Auto Shift to enable these features Pharma 4 by 2 5s Displays and prints clinical trial data in a 4 x 2 5s format with two 2 Rhythm Leads rhythm leads Vector Loops Sagittal horizontal and frontal plane vectorgrams Marks on sample X Y Z complexes identify P onset and offset Q onset and offset and T onset In Test Reports The following formats are available for printing during the test 2046275 016A MAC 5500 MAC 5500 HD 183 Report Formats 12 or 15 Lead Based on Exercise report setups a variety of 12 or 15 Lead report Report formats will print without ECG analysis when the 12 Id key is pressed or when 12 15 lead reports are configured in the protocol 5 Second Rhythm This report can be chosen from the Edit Protocol application to print Report at certain points during the test Rhythm Report A continuous real time recording of raw data 3 6 12 leads Leads for rhythm report correspond to leads on the screen Arrhythmia Report
62. 5 016A MAC 5500 MAC 5500 HD 17 Introduction USA Only For use only on or by order of a physician C CE Mark Symbolizes conformity with applicable EU European Union directives 18 MAC 5500 MAC 5500 HD 2046275 016A Introduction Product and Packaging Labeling This section identifies the product labels and their locations on the product and packaging 2046275 016A MAC 5500 MAC 5500 HD 19 Introduction 20 Refer to the previous illustrations for the locations of the labels identified in the following table re abe Tea o O O LAMP CONTAINS MERCURY Located on the bottom of the device this label DISPOSE ACCORDING TO indicates the device contains mercury and must STATENOCAL LAW be disposed of in accordance with state and local laws Located on the cover of the device this label identifies the product s model number Located on the back of the device this label contains the Disposal and GOST labels Refer to Equipment Symbols on page 17 for detailed descriptions of the symbols REF ESTEEN Located inside the writer compartment this label lt Product Description gt Sv ser uniquely identifies this unit Refer to Product wee MM JUNI Label on page 22 for detailed information GE MEDICAL SYSTEMS INFORMATION TECHNOLOGIES INC 8200 WEST TOWER AVE MILWAUKEE WISCONSI MADE IN COUNTRY Located on the back of the device this label provides regulatory an
63. 51 034 406551 035 406554 033 406554 034 406554 035 900178 001 900178 002 900178 003 900178 101 900178 102 900178 103 900178 201 MAC 5500 MAC 5500 HD 13 Introduction ECG Adapters and Connectors cont d CAM 14 ECG Connector Set Mactrode 14 set AHA M 14 ECG Connector Set Grabber 14 set AHA 900179 203 9490 210 Electrode Adapter Set 10 set 9490 214 Electrode Adapter Set 14 set Acquisition Module Cables The following acquisition module cables have been approved for use with this device Acquisition Module Cables 2016560 001 CAM 14 Coiled Patient Cable 50 in 1 3 m 2016560 003 CAM 14 Coiled Patient Cable round connector 15 ft 4 6 m KISS Aspiration System Accessories The following KISS Aspiration System accessories have been approved for use with this device KISS Aspiration System Accessories 14 MAC 5500 MAC 5500 HD 2046275 016A Introduction KISS Aspiration System Accessories cont d Part Number 30344439 30344440 30344441 30344442 30344443 38401590 93204775 2022862 001 2022862 003 2022862 004 2022862 005 2022862 006 2022862 007 2022862 008 2022862 009 2024037 001 2024038 001 2024039 001 2024040 001 30344365 30344366 30344367 30344368 30344369 30344370 30344371 30344372 30344373 30344374 30344375 30344376 43252125 2046275 016A KISS Upgrade Electrodes amp Leadwires FRANK 4 set 50 in 127 cm H E I
64. 75 016A System Setup Screen To configure how your exercise tests are displayed on the screen log on to the System Setup screen select Exercise Test gt Screen and complete the fields described in the following table Screen Display Rhythm Determines whether the median complex is displayed in front of the Medians Rhythm Lead 1 2 and 3 Screen Filter Determines the filter to use for displaying the exercise test Options are e 20Hz e 40Hz Inputs and Outputs To configure the input and output signals sent to additional equipment such as ergometers connected to the system log on to the System Setup screen select Exercise Test gt Inputs Outputs and complete the fields described in the following table 2046275 016A MAC 5500 MAC 5500 HD 153 System Setup Inputs Outputs Slow Analog Output Determines the slow analog output for controlling external exercise equipment Options include Not Used DC Heart Rate Workload Speed x1 Speed x3 Grade If using exercise protocols for an ergometer or an analog treadmill see Chapter 7 Editing Protocols you must configure the slow and fast analog output properly to control the workload device For ergometers the analog output should be configured for workload for analog treadmills they should be configured for speed and grade Fast Analog Output Determines the lead signals sent to the device Options are Not Used DC Heart Rate Workload Sp
65. 75 016A 29 October 2010 2046275 016A Contents 1 Introduction Product Informativa vsansvass canino cancesuasniasevanneatebenss vans b ke d s n k cake Qs an 9 Indications Tor USE ii NEnEnEnEnmnonunTnRTnENEnEEH HE HNnRnERDRMM 9 Prescription Device Statement ici cad 9 Recording ECGs During Defibrillation 0 ccc cece cece cece cece cece cent eee bee cette een ens 9 Accuracy Of the Input Signal Reproduction LL k 10 Modulating Effects in Digital Systems 0 cc cece ccc e 10 Installation and CONNECHION iia aa Dos berto 10 Parts and Lele sey SJNDMM M MDDMDED E MI JJi NNE HnE En nHnNEHn a EH E heme he Hnz RMPBDP gt IE ZEDE 10 Equiprrient Symbols Io HH HH H el dica od add avam bee bed do 17 Product and Packaging Edbellhng omic ii 19 Equipment Identificati Mees a ooo Leere dl balada DEP RO 22 Regulatory and Safety Information sees 24 Safety Conventions DoDoDDer5Ee_ la aa 24 Safety Messages cec pee ba e mmmmm pirrne 24 e o cfr cera pis e 28 Underwriters Laboratories INC cin nc ere teste eras eoe e 28 EMI EMC Requirements Xl ope eet er al 28 HOGG OMICS da TE A 29 Responsibility of the Manufacturer ssir sk kaka l k k y ence ee 29 Responsibility of the Purchaser CUStOMET ooococoocccccoccnccccccnocnncnicnnnnnnnnninnnnnnnos 29 Service IOMA ON ri sner ye N Eek risane poes RE ER be ERE V n ak 29 Servic
66. AC 5500 HD 37 System Overview wm Teese O 3 Recovery Advances the exercise test to the recovery phase or to the next stage within the current recovery phase Ends the test and starts the test end phase 5 Speed W Adjusts the belt speed on treadmills or load on ergometers Press Speed W to decrease the speed or load Press Speed W to increase the speed or load Adjusts the grade of the treadmill Press Grade to increase the grade press Grade to decrease the grade Starts or stops the treadmill during the test Press Start tmill to manually start the treadmill Press STOP tmill to manually stop the treadmill NOTE In the event of an emergency press and hold the STOP tmill key to stop the treadmill quickly Prints a 10 second delayed recall report Prints a 12 lead report with 10 seconds of acquired data 11 Comment Allows you to enter comments about the test Comments are printed on many of the final reports 12 Enter BP Allows you to enter blood pressure readings or to trigger a reading from an external device Acquisition Equipment This section provides an overview of the external equipment connected to the MAC system for the acquisition of ECG data Familiarize yourself with these components before attempting to acquire ECG data Acquisition Module WARNING BURN PROTECTION Use of acquisition modules other than the CAM 14 or CAM HD acquisition modules could result in high frequency bu
67. E Creating Bar Codes and Magnetic Cards 4 Press esc twice 5 Select Save Setup gt To System Setting Up Master s Step Test 2046275 016A To configure the Master s Step Test log on to the System Setup screen select Master s Step and complete the fields described in the following table NOTE This option is available only Japan Master s Step Setup Number of Steps Defines the default number of steps required by the Master s Step test if the patient s weight sex and age are not entered If the patient s age weight sex and age are entered the number of steps is automatically calculated For more information refer to Appendix D Master s Step Data Test Type Determines the test duration Options are Single Sets the test for a 1 5 minute duration e Double Sets the test for a 3 minute duration Triple Sets the test for a 4 5 minute duration Post J ms Defines the location in milliseconds after the J point to determine the ST measurement Step Counter Display Determines whether the system displays the number of steps taken or remaining Options are e Up Displays the number of steps taken so far Down Displays the number of steps remaining Sound Option Sets the sound volume for the Master s Step Test Select one of the following options MAC 5500 MAC 5500 HD 159 System Setup Master s Step Setup cont d Continuous Determines whether the rhythm is printed continuously
68. ECG Preview Preview allows you to review the ECG on screen before it is printed or stored After the ECG is displayed you can select Continue to print or store the ECG or Cancel to discard it 1 Log into the System Setup function Refer to Process Overview on page 115 2 Select ECG The ECG options are displayed 3 Select ECG Analysis The analysis options are displayed 4 Inthe Preview before analysis field select Yes Press Return 116 MAC 5500 MAC 5500 HD 2046275 016A System Setup Setting Up Resting ECG Report Printing This option allows you to select the report format that will print for different resting ECGs 1 Log into the System Setup function Refer to Process Overview on page 115 2 Select ECG 3 Select the type of ECG reports to configure You have the following options e Resting ECG Reports e Pediatric ECG Reports e 15 Lead Reports e Vector Loops Reports 4 Select Unconfirmed Reports A list of available report formats is displayed 5 Select the type and quantity of formats to print 6 When you are done press Return Setting Up Automatic ECG Storing Use the following procedure to set up the system to automatically store an ECG 1 Loginto the System Setup function Refer to Process Overview on page 115 2 Select ECG ECG Analysis Auto ECG Storage A list of options opens e All ECGs No ECGs Only ABNORMAL ECGs 3 Select the desired option and press Return 2
69. GE Healthcare MAC 5500 MAC 5500 HD Resting ECG Analysis System Operator s Manual Software Version 10 2046275 016 Revision A MAC 5500 MAC 5500 HD Resting ECG Analysis System English 2010 General Electric Company All Rights Reserved Publication Information The information in this manual only applies to MAC 5500 and MAC 5500 HD system software version 10 It does not apply to earlier software versions Due to continuing product innovation specifications in this manual are subject to change without notice MAC MULTI LINK MUSE MACTRODE Ultra Archivist MobileLink and 12SL are trademarks owned by GE Medical Systems Information Technologies Inc a General Electric Company going to market as GE Healthcare All other marks are the properties of their respective owners This product complies with the regulatory requirements concerning medical devices from the following bodies CE 0459 The document part number and revision appear at the bottom of each page The revision identifies the document s update level The revision history of this document is summarized in the following table Revision History 29 October 2010 Initial release of the document To access other GE Healthcare manuals go to the Common Documentation Library CDL located at http www gehealthcare com usen service biomed_tech_selfservice services_user_doc products support html and click Cardiology 2 MAC 5500 MAC 5500 HD 20462
70. Hookup Advisor indicator 1 Select the electrode placement sites for ECG monitoring or diagnosis per the protocol specified by the hospital or physician Refer to Electrode Placement on page 55 for diagrams and descriptions of electrode placement for various protocols 2 Ensure that each site is dry clean and free of excessive hair NOTE Do not use solvents to clean the skin solvents trapped under electrodes may lead to abnormal skin reactions 3 To prepare for a stress test do the following a Mark each electrode site with a felt tip pen b Degrease each site with a skin preparation cream C Use a mild abrasion to remove the mark left by the felt tip pen 4 Apply electrodes to the prepared sites Electrodes should be placed only by a physician or ECG technician WARNING SHOCK HAZARD Touching the conductive elements cancels the protection provided by the isolated signal input Ensure that conductive parts of the electrodes or lead wires do not come in contact with other conductive parts 5 Look at the lead check screen for indication of lead problems NOTE Use only electrodes and contact agents recommended by GE Healthcare The signal quality on the lead check screen is not indicated until the RA R electrode is applied If RA R becomes disconnected the system will report that all electrodes are off the patient 54 MAC 5500 MAC 5500 HD 2046275 016A Preparing the Patient Electrode Placemen
71. I TIPI requires that age range gender and chest arm pain complaints be entered Verify the patient is older than 16 ACI TIPI does not apply for pediatric patients Verify the original ECG was acquired with an electrocardiograph with the ACI TIPI option enabled ACI TIPI information must be gathered when the ECG was acquired For more information refer to Setting Up ACI TIPI Interpretation on page 118 External Device Does Not Record BP Readings If an external device is not automatically recording blood pressure as expected do the following Check the blood pressure device setup Check the serial and TTL cables to make sure they are seated correctly Check the TTL trigger For more information refer to Inputs and Outputs on page 153 Treadmill Ergometer Does Not Move If the exercise equipment is not moving in response to the test protocol do the following 178 Check the protocol Verify it is set up to control the equipment Refer to Chapter 7 Editing Protocols Check the cables Verify that the device is connected to the correct port that the cable is seated securely and that the cable is not frayed or damaged Check the system s input output settings Refer to Inputs and Outputs on page 153 MAC 5500 MAC 5500 HD 2046275 016A e Check the Emergency Stop switch on the device Verify it is not depressed e Check the device settings Verify that it does not retain settings from the previous patie
72. M KISS Upgrade Electrodes amp Leadwires NEHB 2 set 50 in 127 cm Nst Nax MAC 5500 MAC 5500 HD 15 Introduction Papers The following thermal papers have been approved for use with this device Papers 9402 020 Premium Thermal Sensitive Chart Paper Full Page Red Grid 8 5 in x 11 in 216mm x 280mm Sheet Z fold Queue Hole 300 sheets pack 8 packs case 2400 sheets case 9402 021 Premium Thermal Sensitive Chart Paper Full Page Red Grid A 4 Modified 8 26 in x 11 in 210mm x 280mm Sheet Z fold Queue Hole 300 sheets pack 8 packs case 2400 sheets case 9402 024 Premium Thermal Sensitive Chart Paper Red Grid Blank Interpretation Area 8 5 in x 11 in 216mm x 280mm Sheet Z fold Queue Hole 300 sheets pack 8 packs case 2400 sheets case 9402 034 Archivist 100 Thermal Sensitive Chart Paper Full Page Red Grid 8 5 in x 11 in 216mm x 280mm Sheet Z fold Queue Hole 300 sheets pack 8 packs case 2400 sheets case 9402 035 Archivist 100 Thermal Sensitive Chart Paper Full Page Red Grid A 4 Modified 8 26 in x 11 in 210mm x 280mm Sheet Z fold Queue Hole 300 sheets pack 8 packs case 2400 sheets case 9402 061 Premium Thermal Sensitive Chart Paper Red Grid Blank Interpretation Area 8 5 in x 11 in 216mm x 280mm Sheet Z fold Queue Hole 150 sheets pack 16 packs case 2400 sheets case Miscellaneous Accessories The following miscellaneous accessories have been approve
73. Menu MAC 5500 MAC 5500 HD 87 Editing Protocols 88 MAC 5500 MAC 5500 HD 2046275 016A Printing ECG Reports The MAC system can be configured to print a report automatically during an ECG test In addition you can choose to reprint an ECG report in a different format during the test Finally you can print ECG reports that are stored on the system This chapter explains how to print another report during the ECG test how to print a stored ECG report and how to store the printouts after they print For information on how to configure the MAC system to automatically print a report refer to Chapter 14 System Setup Printing Another Report Use the following procedure during an ECG test to print the ECG data in a different report format 1 oO m FW m Run the test The system automatically prints a report as configured in System Setup Select More to view the second screen of options Select New Format Highlight the additional report format s to print Press Return Select Print or press the Copy key to print the selected reports NOTE Changes made here affect only the current ECG Once another ECG is recorded the reports specified in System Setup are printed Printing Stored ECGs Use the following procedure after an ECG test to print stored reports 2046275 016A 1 Press File Manager A list of stored ECG reports opens Press Select Select the ECG s to print Press Print MAC
74. Obtain a configuration bar code For information on creating patient bar codes refer to Appendix E Creating Bar Codes and Magnetic Cards 2 Connect the bar code reader to port A on the back of the system al From the Main Menu select System Setup gt Basic System gt Input Method Select gt Patient Data Input Device gt Bar Code Reader gt Return When the Manual Bar Code Reader Configuration window opens press esc When the Basic System menu opens press esc Select Save Setup gt To System Restart the device Oo t 01 x e From the Main Menu select System Setup Basic System Input Method Select Bar Code Reader Configuration Automatic Return The following message is displayed Scan the Configuration Bar Card 9 Scan the bar code The Manual Bar Code Reader Configuration window opens with the values filled in 10 Press esc twice 11 Select Save Setup To System Manual Configuration Use the following procedure to manually configure your bar code reader 1 Connect the bar code reader to port A on the back of the system 2 From the Main Menu select System Setup Basic System Input Method Select Patient Data Input Device Bar Code Reader Return The Manual Bar Code Reader Configuration window opens 158 MAC 5500 MAC 5500 HD 2046275 016A System Setup 3 Enter the bar code configuration information For information on creating bar codes refer to Appendix
75. Only Setup window select System Setup press Shift F2 and enter the service password to view the serial number Contact GE Healthcare support if you do not know the service password 2046275 016A MAC 5500 MAC 5500 HD 23 Introduction Regulatory and Safety Information This section provides information about the safe use and regulatory compliance of this device Familiarize yourself with this information and read and understand all instructions before attempting to use this device The system software is considered medical software As such it was designed and manufactured to the appropriate medical regulations and controls Any exceptions are noted in the Compliance Information Exceptions section NOTE Disregarding the safety information provided is considered abnormal use of this device and could result in injury loss of data and void any existing product warranties Safety Conventions A Hazard is a source of potential injury to a person property or the product This manual uses the terms DANGER WARNING and CAUTION to point out hazards and to designate a degree or level of seriousness Familiarize yourself with the following definitions and their significance Definitions of Safety Conventions Safety Definition Convention Indicates an imminent hazard which if not avoided will result in death or serious injury WARNING Indicates a potential hazard or unsafe practice which if not avoided could result in deat
76. Options are e Numbers and Letters Numbers only e Yes or No Setting Up a Card Reader This section describes two methods for configuring the magnetic card reader e Automatic Configuration Manual Configuration NOTE When configured for a card reader the system will prompt you to slide the patient card when you select Patient Information If no patient card is available press esc to enter the patient information manually 156 MAC 5500 MAC 5500 HD 2046275 016A System Setup Automatic Configuration Use the following procedure to automatically configure your magnetic card reader 1 oN OF Um J gt 10 11 Obtain a configuration card For information on creating magnetic patient ID cards refer to Appendix E Creating Bar Codes and Magnetic Cards With the card reader properly mounted connect to port A on the back of the system From the Main Menu select System Setup gt Basic System gt Input Method Select gt Patient Data Input Device gt Card Reader gt Return When the Manual Card Reader Configuration window opens press esc When the Basic System menu opens press esc Select Save Setup gt To System Restart the device From the Main Menu select System Setup gt Basic System gt Input Method Select gt Card Reader Configuration gt Automatic gt Return The following message is displayed Slide the Configuration Card Slide the configuration card through the card
77. SD Card After files have been copied to an SD card you can use the Restore All function to copy files from the SD card to internal storage NOTE If CT Data Guard is enabled and its Prevent deleting of untransmitted records field is set to Yes you will receive the following warning if any of the records in internal storage have not been transmitted The operation deletes existing records This cannot be done since there are untransmitted records If you receive this message make sure that all records have been transmitted and try Restore All again 1 Insert an SD card with ECGs into the system s card slot Refer to Inserting and Ejecting the SD Card on page 108 Select File Manager to open the list of stored ECGs Select Restore All The following message is displayed Existing records if any in memory will be deleted Continue Do one of the following To cancel the copy select No To continue copying the files select Yes The following message is displayed Deleting existing records if any in memory Please wait An indicator shows the progress completion of the copying procedure Saving Files in XML Format In addition to transmitting ECG records as XML files to a PC see Transmitting ECGs in XML Format on page 94 the MAC system can save ECG records as XML files on an SD card 1 Insert an SD card into the system s card slot Refer to Inserting and Ejecting the SD Card on page 108 2
78. SUPPLIES Parts and accessories used must meet the requirements of the applicable IEC 60601 series safety standards and essential performance standards and or the system configuration must meet the requirements of the IEC 60601 1 1 medical electrical systems standards To ensure patient safety use only parts and accessories manufactured or recommended by GE Healthcare CAUTION ACCESSORIES EQUIPMENT The use of accessory equipment that does not comply with the equivalent safety requirements of this equipment may lead to a reduced level of safety of the resulting system Consideration relating to the choice of equipment shall include e Use of the accessory in the patient vicinity and Evidence that the safety certification of the accessory has been performed in accordance with the appropriate IEC 60601 1 and or IEC 60601 1 1 harmonized national standard MAC 5500 MAC 5500 HD 2046275 016A 2046275 016A Introduction CAUTION BATTERY POWER If a device equipped with an optional battery pack will not be used or connected to the power line for a period of over six months remove the battery CAUTION BEFORE INSTALLATION Compatibility is critical to safe and effective use of this device Please contact your local sales or service representative prior to installation to verify equipment compatibility CAUTION DISPOSABLES Disposable devices are intended for single use only They should not be reused as perfor
79. Select File Manager to open the list of stored ECGs Highlight the record s to export as XML 4 Select Save XML 110 The ECGs are converted to XML and saved to the SD card MAC 5500 MAC 5500 HD 2046275 016A Using an SD Card Updating Software from the SD Card 2046275 016A When a software update is made available for the MAC system it is provided on an SD card Use the following procedure to apply the update NOTE Connect the system to AC power before you begin the software update Keep the system connected to AC power during the software update and do not power off the system during the software update Press Power to turn on the system From the Main Menu select System Setup Enter the system password and press Enter Press Shift F3 The following message is displayed Please Insert SD Card Press Esc to cancel 5 Insert the SD card The following message is displayed PAN Op Current Version xx xx New Software Version yy yy Press Enter to start update 6 Press Enter NOTE If the system is not connected to AC power the message Please switch to AC Power is displayed Connect the system to an AC outlet A series of messages flash on the screen to indicate the installation progress One of two things will happen e If the system does not need a boot code update the following messages are displayed Programming Over System is Shutting Down The system shuts down Skip to step 8 e If th
80. The diagnostic statements open Select the statement to edit To add text to the beginning of the selected statement do the following a Press Insert The following message is displayed The new statement will be inserted BEFORE the current statement Select statement type b Select the type of statement to insert The options are Acronym Freetext Newline C Enter a 12SL library acronym or free form text and press Return To add text to the end of the selected statement do the following a Press Append The following message is displayed MAC 5500 MAC 5500 HD 101 Editing ECGs 102 10 11 12 13 14 The new statement will be inserted AFTER the current statement Select statement type b Select the type of statement to insert The options are Acronym Freetext e Newline C Enter a 12SL library acronym or free form text and press Return To join the selected statement with another statement select the second statement and press Join To delete the selected statement press Delete Continue to edit statements as necessary When you are done press Return twice The following message is displayed Select Store to save the edited file This will replace the original file Select Cancel or press Esc to discard the changes made to the current file Select Store to save the edited file MAC 5500 MAC 5500 HD 2046275 016A Deleting ECGs and Orders To free up storage spa
81. ality e Do not allow fluid to pool around connection pins If this happens blot dry with a soft lint free cloth e Never use conductive solutions or solutions that contain chlorides wax or wax compounds to clean the device cables or leadwires Never use solutions or products that contain any type of Ammonium Chloride such as but not limited to Dimethyl Benzyl Ammonium Chloride Quaternary Ammonium Chloride solutions Abrasive cleaners or solvents of any kind Acetone e Ketone e Betadine e Alcohol based cleaning agents e Sodium salts e Never autoclave or steam clean the device cables or leadwires Do not use until thoroughly dry Cleaning Disinfecting and Storing ECG Cables and Leadwires In addition to keeping the MAC system clean and in good repair it is important to keep the leadwires clean and disinfected This section provides instructions for cleaning disinfecting and storing ECG cables and leadwires to extend their life and protect patients NOTE This information applies to the Multi Link cable and leadwires For systems with the optional KISS system see the KISS operator s manual for cleaning and disinfecting information Cleaning and Disinfecting Leadwires 2046275 016A Proper cleaning and disinfecting prolongs the life of cables and leadwires Failure to use the proper cleaning solutions or to follow proper procedures can result in the following e Damage or corrosion Diminish
82. an Determines whether the system will prompt you to enter the name of the technician conducting the test Select Yes to prompt for this information When entering the technician s ID enter numbers that are compatible with the MUSE CV system to which the MAC system communicates Tech Required Determines whether the technician s name is required Select Yes to require the technician s name Location Determines whether the system prompts for the test location Select Yes to prompt for location Enter numbers that corresponds with the locations on the MUSE CV system with which this unit communicates Room number Determines whether the system prompts for the room number where the test was taken Select Yes to prompt for room number Determines whether the system prompts for the option number for the ECG Select Yes to prompt for the option number Option numbers are user defined Order number Determines whether the system prompts for the order number for the ECG Select Yes to prompt for order number Secondary ID Determines whether the system prompts for a second ID for the ECG Select Yes to prompt for secondary ID Visit Determines whether the system prompts for the Visit ID Select Yes to prompt for the Visit number Extra Questions Allows you to define custom questions to prompt for For each question select the type of information that can be entered Numbers and letters Allows the entry of any alphanumeric value Numbe
83. and affect signal quality Do not allow fluid to pool around connection pins If this happens blot dry with a soft lint free cloth Never use conductive solutions or solutions that contain chlorides wax or wax compounds to clean the device cables or leadwires MAC 5500 MAC 5500 HD 2046275 016A Storage Maintenance e Never use solutions or products that contain any type of Ammonium Chloride such as but not limited to Dimethyl Benzyl Ammonium Chloride Quaternary Ammonium Chloride solutions Abrasive cleaners or solvents of any kind Acetone Ketone Betadine Alcohol based cleaning agents Sodium salts e Never autoclave or steam clean the device cables or leadwires Do not use until thoroughly dry Use the following guidelines when storing acquisition modules Always remove the batteries when the device is not in use even for short periods of time Store in a dry well ventilated area Hang the device using a holder if available If leadwires are attached they should hang straight Do not coil leadwires or cables around the device Battery Compartment Cleaning NOTE 2046275 016A This procedure applies only for frequency hopping telemetry transceivers It should not be used for other devices Under normal operation the battery compartment should not require cleaning If the battery compartment should require cleaning use the following instructions CAUTION DEVICE MALFUNCTION Clean
84. ard channel e the rhythm reporting method e the leads used for each rhythm report lead group e the autorhythm lead group e the extra leads used by the CGR and RMR reports e the leads used by the Swedish rhythm report e the method used for the median report The settings are essentially the same for each ECG type although the available values for each setting may differ depending on the ECG type 148 MAC 5500 MAC 5500 HD 2046275 016A System Setup Use the following instructions to select the correct Report Leads for each report type 12 Lead Exercise Report System Setup gt Exercise Test gt 12 Lead Exercise gt Report Leads 15 Lead Exercise Report System Setup gt Exercise Test gt 15 Lead Exercise gt Report Leads Report Leads Standard leads Defines which leads will print for each channel When you change a channel s lead the new lead will print on all exercise reports that include the channel For the 12 Lead Exercise Reports you can define the lead for channels 1 through 12 For the 15 Lead Exercise Reports you can define the lead for channels 1 through 15 Rhythm reports Defines the data displayed on the rhythm reports Real time Prints the ECG data currently on the screen 10 sec delayed Delays the printing by 10 seconas Rhythm leads Defines the lead option for each of the six rhythm groups to determine the rhythm leads that print when you select the rhythm key within an application e Select 3
85. ation on how to configure the MAC system to automatically print a report refer to Chapter 14 System Setup NOTE When transmitting ECGs to another MAC system the receiving MAC system must be set up to receive the ECGs Refer to Chapter 10 Receiving ECGs for details Transmitting ECGs via Modem If you purchased an optional modem you can transmit ECGs via modem Before using the following procedure make sure your modem is connected to an analog phone line as shown in the following illustrations 2046275 016A MAC 5500 MAC 5500 HD 91 Transmitting ECGs Internal Modem External Modem 4 5 Select File Manager A list of ECGs opens Select Location A list of devices to which the ECG report can be transmitted opens Do one of the following e If the receiving device is shown select it and continue to step 4 e If the receiving device is not shown manually enter the device a Select Location b Select Manual Dial c Enter the telephone number of the receiving device d Press Return e Select the modem type f Press Return g Continue to step 4 Select the ECG s to be transmitted Select Transmit Transmitting ECGs Locally 92 Use the following procedure to transmit ECGs locally that is within the facility Using this method the devices must be connected via a manual line serial line or Ethernet line 1 Press File Manager A list of ECGs opens
86. caigas d Wae n eee k ballay Meral d ye leavsencceosgedet 187 Si RU CHONG ala iia 190 Creating Bar Codes and Magnetic Cards Manual Reader Configuration eese eese eerte eene enne enne 191 Automatic Reader Configuration eese eene eene en nente 193 MAC 5500 MAC 5500 HD 2046275 016A Introduction This chapter provides information required for the proper use of the product and manual Familiarize yourself with this information before using the product Product Information This section provides a general overview of the product A detailed description of the product can be found in Chapter 2 System Overview Indications for Use The MAC 5500 5500 HD ECG Analysis System is intended to acquire analyze display and record electrocardiographic information from adult and pediatric populations Basic systems deliver 3 6 12 or 15 lead ECG s interpretive analysis vector loops and can be upgraded to provide software analysis options such as high resolution signal averaging of QRS and P wave portions of the electrocardiogram Transmission and reception of ECG data to and from a central ECG cardiovascular information system is optional The MAC 5500 HD is intended to be used under the direct supervision of a licensed healthcare practitioner by trained operators in a hospital or medical professional s facility Prescription Device Statement CAUTION United States federal law restr
87. ce the MAC system allows you to delete ECGs and uncompleted orders This chapter describes those procedures Deleting ECGs To delete ECGs you must enter a System or Overread password if the passwords are defined You should only delete ECGs that have been transmitted to another ECG a MUSE CV system or a PC for storage 1 2046275 016A Press File Manager A list of ECG reports opens Press Select The cursor is displayed on the screen Highlight the ECG report s to delete Press Delete Depending on system setup you may be prompted for a password If prompted enter the System or Overread password NOTE The System password should only be used by the system administrator or qualified service personnel All other users should use the Overread password The following message is displayed Warning You have selected files for delete This is the only warning you will receive Do you want to delete these files Do one of the following e To delete the select ECG report s press Yes To cancel the deletion and select different reports press No MAC 5500 MAC 5500 HD 103 Deleting ECGs and Orders Deleting Orders 104 Use the following procedure to delete orders stored locally on the device 1 From the Mqin Menu select Ord Mgr Int NOTE Depending on the options enabled on your system you may need to select More to toggle through the menu until Ord Mgr Int is available The Order Manager Int
88. ck avoid the carotid artery and jugular vein 10 M light blue Center of spine on the same horizontal level as 3 and 4 2046275 016A MAC 5500 MAC 5500 HD 57 Preparing the Patient NEHB Placement AHA Label IEC Label Description ssi Al orange Nst white Attachment point of the second rib to the right sternal edge A2 orange Nax white Fifth intercostal space on the left posterior axillary line Same position as V8 or C8 3 V4 blue Nap white Mid clavicular line in the fifth intercostal space Same position as C4 58 MAC 5500 MAC 5500 HD 2046275 016A Preparing the Patient Pediatric Placement 2046275 016A Eb Fourth intercostal space at the right sternal border V2 yellow C2 yellow Fourth intercostal space at the left sternal border Midway between location 2 and 4 Ou C5 black Anterior axillary line on the same horizontal level as A V6 purple C6 purple Mid axillary line on the same horizontal level as 4 and 5 7 LA black LA black Left deltoid LL red F green Above left ankle Alternate placement upper leg as close to torso as possible close to torso as possible Mid clavicular line in the fifth right intercostal space E 13 Same horizontal level of 4 in the left posterior axillary line 10 11 V4 blue Mid clavicular line in the fifth intercostal space MAC 5500 MAC 5500 HD 59 Preparing the Patient Exercise ECG Placement The following methods are app
89. code identifying the year the device was manufactured Values range from 00 to 99 For example 00 2000 04 2004 05 2005 and so on Fiscal Week Two digit code identifying the week the device Manufactured was manufactured Values range from 01 to 52 GE Healthcare s fiscal weeks correspond to the calendar week For example 01 first week in January Product Sequence Four digit number identifying the order in which this device was manufactured Values range from 000 to 9999 Manufacturing Site One letter code identifying the site where the device was manufactured For example F Milwaukee N Freiburg P Bangalore Miscellaneous For example P unit is a prototype R unit was Characteristic refurbished U unit was upgraded to meet the specifications of another product code Product Codes The product code identifies specific system platforms You need the product code before servicing or requesting support for your device You can identify the product code using the serial number listed on the product label located in one of the following places e On the product label attached to the base the system On the product label provided with the application CD In the application On IT systems Launch the system application and click Help gt About to view the serial number For information on launching the application refer to the product s service or operator s manual On MAC systems On the Service
90. cribe the available formats so you can choose the correct report for your needs Numeric Reports Several reports use numeric titles that describe the way in which the data is presented For example the report 4 by 2 5s 1 rhythm Id presents the following information WITZKE DEREK ID 000123ABC 25 Aug 1998 8 50 36 MARQUETTE MEDICAL 20ycors Vent rate 82 bpm Normal sinus rhythm Male Caucasian interval 164 ms Nonspecific T wave abnormality Tin 180lbs 72 ms Room ER 354 413 ms oc 2 Opt 1 PRTaxes 70 65 61 Abnormal ECG History Unknown Technician NICKULIS Meds ASPIRIN Secondary ID ABC098 Order no 567 Referred by PETERSEN DAVID Unconfirmed smoking No alcho Prompt One OUTPATIENT Prompt Two Yes 2 ot eet SENAN A 150 Hz 25 0 mm s 10 0 mm mV 4 hy 2 58 1 rhythm ld MAC5K 1 128LU y252 1 Four columns of data containing 3 leads with 2 5 seconds of data in each lead 4 by 2 55 2 One 10 second rhythm lead 1 rhythm ld The following numeric reports are available e 2by5 e 2 5s 50 mm s writer speed e 2by 5s 1 rhythm lead 2046275 016A MAC 5500 MAC 5500 HD 181 Report Formats 2 by 10s e 3by5 0 50mm s e 3 by 10s e 4 by 2 5s e 4 by 2 5s 1 rhythm lead e 4 by 2 5s 3 rhythm leads e 4 by 10s e 5 by 2s e 5 by 2s 1 rhythm lead e 5 by 2s 3 rhythm leads e 5 by 10s Additional Reports The following additional report formats are available 182
91. d cautionary information Refer to Equipment Symbols on page 17 for detailed descriptions of the symbols 50 60Hz 0 85A mac pac Eu amp Located inside the battery compartment this label provides information about the specifications and disposal of the battery Refer to Equipment Symbols on page 17 for detailed descriptions of the symbols Se Located on the front of the device this label indicates that in the USA federal law restricts sale of the device to or on the order of a physician Located below the display this label indicates the de device uses the Marquette 12SL ECG Analysis MARQUETTE Program to analyze and interpret ECG readings Located on the back of the device this label EE identifies the device s electrical ratings MAC 5500 MAC 5500 HD 2046275 016A Introduction CIN CT 10 Located to the right of the display this label instructs the user on where to place leads Located on the package the shipping label contains the following information Product description Sales order number Configuration number Model number GE Medical Systems Information Technologies Inc M 8200 W Tower Ave Milwaukee Wisconsin USA Made in India Serial number BE Modical Systems Information Technologies GmbH Munzingerstasse 5 79111 Froiburg Garmany TN Storage conditions Regulatory compliance Country of Origin EC Representative infor
92. d for use with this device Miscellaneous Accessories 16 MAC 5500 MAC 5500 HD 2046275 016A Introduction Equipment Symbols The following symbols may appear on the product or its packaging Type BF equipment The acquisition module is protected from defibrillation shocks Alternating Current Equipotential Charge the battery The flashing amber LED next to this symbol indicates you must connect the system to AC power to recharge the battery Waste of electrical and electronic equipment must not be disposed as unsorted municipal waste and must be collected separately Please contact an authorized representative of the manufacturer for information concerning the decommissioning of your equipment Recycle the battery Consult the accompanying documentation Classified with respect to electric shock fire mechanical and other specified hazards only in accordance with applicable UL standards To reduce the risk of electric shock do NOT remove cover or back Refer servicing to qualified personnel This product consists of devices that may contain mercury which must be recycled or disposed of in accordance with local state or country laws Within this system the backlight lamps in the monitor display contain mercury Manufacturer name and address Authorized European representative PCT GOST marking symbolizing conformity with applicable Russian Gosstandart technical and safety standards 204627
93. d to select the ergometer workload treadmill speed or treadmill grade as appropriate b Enter the desired value c Toindicate no in workload speed or grade delete the value d When you are done press Return WARNING FALLING HAZARD Severe injury can result from a fall Patients should wait until the treadmill belt is moving before stepping onto the belt Step onto the belt with one foot at a time Avoid rapid changes in belt speed To change the report a b C d Use the arrow pad to select the Report Style field Click the arrow pad button to open the Report Style pop up Highlight the report you want to print at this stage When you are done press Return e To change Report Median or BP times a b e Use the arrow pad to select the appropriate First field Enter the time at which you want the selected event to occur To prevent the event from occurring delete the value in the field Use the arrow pad to select the appropriate Repeat field Enter the frequency at which you want the selected event to occur To prevent the event from recurring delete the value in the field When you are done press Return To add another stage a Use the arrow pad to select the stage you want to add the new stage after Press Add You can now use any of the previous options to edit the stage as appropriate MAC 5500 MAC 5500 HD 2046275 016A 2046275 016A 10 11 12 13
94. d water solution to moisten the cloth Do NOT use any of the following cleaning products or products that contain the same active ingredients and solutions which are known to cause the problems previously listed e Sani Cloth Wipes Ascepti Wipes HB Quat e Clorox Wipes they do not contain bleach Over the counter detergents such as Fantastic Tilex and so on To disinfect wipe with a soft lint free cloth moistened with an appropriate disinfectant Use the following solutions as recommended in the APIC Guidelines for Selection and Use of Disinfectants 1996 e Sodium hypochlorite 5 296 household bleach minimum 1 500 dilution minimum 100 ppm free chlorine and maximum 1 10 dilution e Any sodium hypochlorite wipe product that meets the previous guidelines can be used Allow the cleaning solution disinfectant to remain on the device for a minimum of one minute or per hospital guidelines Wipe off the cleaning solution disinfectant with a clean moistened cloth Dry thoroughly with a dry lint free cloth and let air dry for a minimum of 30 minutes before use DO NOT use excessive drying techniques such as oven forced heat or sun drying NOTE Drying times may vary based on the environmental conditions Follow the cleaning instructions exactly Wring excess disinfectant from wipe before using Never immerse the device cables or leadwires in any liquid as this may corrode metal contacts
95. dentified leads I Il AVR aVL aVF selects the identified leads V1 V2 V3 V4 V5 V6 selects the identified leads Lead check conducts a check of all available leads and displays their results Lead placement conducts a lead check and displays a diagram of the proper placement for each lead To adjust the speed with which the waveforms are displayed press 25 mm s This opens a list of available speeds Options include 5 mm s 12 5 mm s 25 mm s and 50 mm s This affects only the speed of the waveform as it appears on the screen and reports it does not affect the actual speed with which the ECG is recorded The selected value appears on the function key on the screen e To adjust the gain of the ECG press 10 mm mV MAC 5500 MAC 5500 HD 73 Recording an ECG 74 This opens a list of available gains Options include 2 5 mm mV 5 mm mV 10 mm mV 20 mm mV and 10 5 The selected value appears on the function key on the screen To adjust the filter of the printed ECG press 150 Hz This opens a list of available filters Options include 20 Hz 40 Hz 100 Hz and 150 Hz This affects only the printout the screen filter is always set to 40 Hz The selected value is displayed on the function key To change the pacemaker enhancement press More gt Pace Gain This opens the Pacemaker Enhancement window Highlight Pacemaker Enhancement press Return and select Yes To turn on the Acute Coronary Syndrome algorithm press M
96. der creation 2046275 016A MAC 5500 MAC 5500 HD 129 System Setup Order Manager Interface cont d Auto order delete Determines whether the system will automatically delete orders under the following conditions e the orders have been successfully transmitted to a receiving device and e the associated ECGs have been transmitted and deleted This field is NOT dependent on the Delete after transmit field on the Miscellaneous Setup window Both fields operate independently Default order Identifies the locations displayed on the prompt when downloading locations orders This will typically be the device s location see Miscellaneous Setup on page 119 If the device is used in multiple locations enter multiple locations and separate them with commas 1 3 10 and so on Input Method To configure the how the system s PS 2 port will be used log on to the System Setup screen select Basic System gt Input Method Select and complete the fields described in the following table Input Method Patient Data Input Determines which device will be connected to the PS 2 port Valid Device options are PS 2 Keyboard Card Reader Bard Code Reader Internal Keyboard Query Configuration Determines how the input device should be configured Valid values vary depending on the selected device If you select Card Reader or Bar Code Reader the valid options are Automatic Manual None If you select Interna
97. e pe Hae DA e na X N 147 Patient OUEN Se pr Y mm 147 Writer SUD car aora We 148 Sr aJ NSS u c ede ine ES ERE ERE ee P e Eee EM SERENA dde 148 Serm aa dias 153 Inputs and OUTPUTS eeni ut td its 153 MAC 5500 MAC 5500 HD 2046275 016A 2046275 016A Setting Up d Card REGEN rita 156 Automatic Coniqgurdtioms sede t ceto rb oet T ca da 157 Manual COURSE 157 Setting Up a Bar Code Reader eene 158 Automatic Configuratio erases ei say hawa e EE re re b ea e daa eee e x eoe 158 Man glxConfig ration xc sii dade dolere Rt ER A 158 Setting Up Master s Step Test oooocnnnncccnonocnnononoccnnnnnnnonnonnconocnonoononnnnnnos 159 Managing System Setup xereke kereke ke kek k kake ke kek k nennen HA HARA 160 Printing System Setup ssec os cae ROO POR OR RE ERES ERE RE pe h ne 160 SAVIO SYSTEM Setup xy yad e eeu eb e eee be pen ee debe uk get s e teu 160 Restoring System Setup coca ne cased Naat di NE HERR RR DE PERI P EE eaten RETA AREE 160 Maintenance Inspecting and Cleaning the MAC System essere 163 Inspecting the MAC System s sati yey yb bey ken dene We ee Wan a e O be W ee h n 163 Cleaning and Disinfecting Exterior Surfaces 2 0 c eee e cece eee ee ee ee en eens 164 Cleaning Disinfecting and Storing ECG Cables and Leadwires sss 165 Cleaning Disinfecting and Storing Handheld Devices
98. e Before using the following procedure connect and configure the MobileLink wireless device as described in the MobileLink Installation and Troubleshooting Guide 1 Press File Manager A list of ECGs opens Press Location A list of locations opens Highlight a Serial Line location with a Type of MUSE Network and press Select A list of ECGs opens Select the ECG s to transmit Press Transmit MAC 5500 MAC 5500 HD 93 Transmitting ECGs Transmitting ECGs in XML Format Most methods transmit ECGs in GE Healthcare s proprietary Hilltop format You can however use the following procedure to transmit ECGs in XML to a PC the data can then be extracted for analysis 94 1 Connect the serial port of the MAC system to the serial port of a PC running a terminal emulation program On the MAC system press File Manager A list of ECGs opens Press Location A list of available locations opens Highlight a Serial Line location with a Type of XML Output and press Select A list of ECGs opens Select the ECG s to transmit Press Transmit MAC 5500 MAC 5500 HD 2046275 016A Receiving ECGs This chapter explains how to receive ECGs from other MAC systems and from a MUSE CV system Receiving ECGs from Another MAC System Chapter 9 Transmitting ECGs explains how to manually transmit ECGs from one MAC system to another However in order to receive those ECGs on the other MAC system the receivi
99. e Agreement exists The sole responsibility rests with the individuals hospitals or institutions utilizing the device Inspecting and Cleaning the MAC System When inspecting and cleaning your system take the following precautions Turn off the system Do NOT immerse any part of the equipment in liquid Do NOT use organic solvents ammonia based solutions or abrasive cleaning agents These may damage the equipment surfaces Inspecting the MAC System 2046275 016A Perform a visual inspection of all equipment and peripheral devices daily If you notice any items that need repair do not use the equipment until an authorized service person has completed the repairs e Check the case and display screen for cracks or other damage e Inspect all plugs cords cables and connectors for fraying or other damage MAC 5500 MAC 5500 HD 163 Maintenance e Verify that all cords and connectors are securely seated e Inspect keys and controls for proper operation e Toggle keys should not stick in one position e Knobs should rotate fully in both directions Cleaning and Disinfecting Exterior Surfaces Clean and disinfect the exterior surfaces of all equipment and peripheral devices monthly or more frequently if needed Cleaning and Disinfecting the Surfaces Proper cleaning and disinfecting prolongs the life of the product Failure to use the proper cleaning solutions or to follow proper procedures can result in the following
100. e R qUlre m l Sy xa ed der tede tee st bre Tee M T ede n RUM M RR Be KA dekan 29 Additional AsSISLIBCe VD 0 a ride be No dug U Eod supe PE a ow ladies 29 Manual WATT VION E E ERE Os 30 Manual PUDO eri reae titer eee ara did O MD ITDDM E 30 Intended Audience e ee e eee eene he eere nennen nns 30 DOCUMENT CONVENTIONS ausser co eR E ban WA e s bet M ke aka 30 Related Docus eT sae ke er IR ped van baw lan 31 O i A MM ZZ M E 31 System Overview Hardware Descrip 33 A O 33 BACK VIEW NO 34 Internal Vi Wisin ctra G 34 A DD J _ __rrm g_ eTEN EE E a 35 Keyboard Standand Keys 2 esce Mane vote repere lcd 36 Keyboard Exercise Test Keys OptiOM ooooooococcocococccccococoncoconcononconnncononss 37 Acquisition EQUIPO Larra 38 Acquisition Module es a sedge ct A ds derya H nde ok 38 Fele Wr d H N ies 39 Leadwire AdGpt l S Jp ccr Marek bin dida benk Me mk bei 40 Connecting Peripherals n quos pre P kirin a 40 Connecting the LAN OPtlON ies silo E elan naa sirk b e a lee 41 MAC 5500 MAC 5500 HD Connecting the ModeM OOtiON ais sede icr i etc gen Reda e ul n k 41 Connecting the MobileLink Wireless Option 00 0 ccc k 41 Connecting External Exercise DeVICES 0 cece kk 41 Connecting the Acquisition D VICE occ cence cece kk 41 Verifying CorrectOperatior 5 e o en E t de tres UA 42 Software OVERVIEW T 42
101. e field 3 Press either the middle button of the Arrow Pad or the Return key to enter the data into the field The cursor moves to the next data field 50 MAC 5500 MAC 5500 HD 2046275 016A System Overview Selecting Data from a Drop down List 2046275 016A E ame Using the Arrow Pad press the arrow keys to highlight the desired field Press the middle button of the Arrow Pad A list of available values drops down Using the Arrow Pad press the arrow keys to highlight the desired value Press the middle button of the Arrow Pad to select the desired value The value is entered into the field and the cursor moves to the next data field MAC 5500 MAC 5500 HD 51 System Overview 52 MAC 5500 MAC 5500 HD 2046275 016A Preparing the Patient 2046275 016A This chapter provides the procedures for preparing the patient s skin and properly placing electrodes Some of the procedures for placing electrodes may not apply in all cases depending on the system and options purchased NOTE These instructions do not cover the application of electrodes for the KISS Electrode Application System not available in the United States To use the KISS system see the KISS operator s manual for instructions MAC 5500 MAC 5500 HD 53 Preparing the Patient Preparing the Patient s Skin Careful skin preparation is the key to an interference free ECG Signal quality is indicated on the device via the
102. e method Refer to Chapter 4 Entering Patient Information for more information 3 Select More gt Setup confirm the following parameters are correct and press Return Number of steps e Test type e Post J ms Step Counter Display Sound Option Continuous Recording Post Exercise ECG Time 4 Press the ECG button to record a pre exercise ECG Remove the leadwires but keep the electrodes on the patient This prevents the patient from tripping on the leadwires during the test 6 Press Continue to begin the exercise test 7 When the patient finishes the exercise immediately reattach the leadwires to the electrodes Check the waveform quality on the screen to confirm that all the leadwires were correctly reattached 8 Press Continue The system records the ECG and prints a final report If the system is set up to automatically store ECGs it will also automatically store the ECG 9 If the system is not set up to automatically store ECGs or if it is unable to store the ECG select Store to store the ECG manually 10 You are now ready to transmit the ECG data to a MUSE system Refer to Chapter 9 Transmitting ECGs for details 76 MAC 5500 MAC 5500 HD 2046275 016A Exercise Stress Testing Exercise Stress Tests are optional features that allow you to conduct ECG tests while the patient exercises on a treadmill or ergometer For information on enabling the 12 Lead Exercise and 15 Lead Exe
103. e system needs a boot code update the following messages are displayed Current Boot Version xx xx New Boot Version yy yy Press Enter to start Installation 7 Press Enter to update the boot code The following messages are displayed Programming Primary Boot Programming Over System is Shutting Down The system shuts down MAC 5500 MAC 5500 HD 111 Using an SD Card 8 Press Power to turn on the system 9 Verify the software version has been updated 112 MAC 5500 MAC 5500 HD 2046275 016A System Setup This chapter describes how to use System Setup to configure your system It provides an overview of the setup process and details on how to set up e Automatic tasks System basics e ECGs e Signal Averaged ECGs e Exercise Stress Tests e Master s Step Tests Card Readers Bar Code Readers In addition the chapter provides an overview of the System Setup hierarchy and instructions on how to print save and restore the system settings System Setup Hierarchy 2046275 016A The following list shows the hierarchy of the device s System Setup menu Use it to help you locate the system settings to configure Basic System e Miscellaneous Setup e Patient Questions Screen Colors e Transmission Network Setup Option Activation e Date and Time e Language Power Up Options MAC 5500 MAC 5500 HD 113 System Setup 114 Order Manager Interface e Input Method Select ECG e ECG Acqui
104. e the following instructions to load paper into the MAC system Refer to the following illustration 1 Open the writer drawer 2 Place the pad of paper with the holes on the left 2046275 016A MAC 5500 MAC 5500 HD 171 Maintenance 3 Advance the first sheet of paper 4 Close the writer drawer securely Battery Maintenance Proper battery maintenance prolongs the battery life and ensures that the MAC system will operate when needed Proper maintenance consists of the following Charging the battery Conditioning the battery Replacing the battery Charging the Battery A fully charged battery ensures that the MAC system will operate without being connected to an AC outlet The MAC system s battery should be charged at the following times Before initial use Between acquisitions e When the battery is low When the battery is completely discharged To determine when the battery is low use the battery gauge icon that appears in the upper right corner of the system screen mL O el off olf Item Description 1 Battery gauge icon position Battery 1 2 charged Battery 1 4 charged Battery fully discharged NOTE The system may run for a long time after the fully discharged icon appears When the battery is fully discharged the system will power off To operate your system at that time you must connect the system to an AC wall outlet Battery fully charged 172 MAC 5500 MAC 55
105. ection against fading from external causes e Do NOT store thermal papers with any of the following carbon and carbonless forms document protectors envelopes and sheet separators containing polyvinyl chloride or other vinyl chlorides non thermal chart papers or any other products containing tributyl phosphate dibutyl phthalate or any other organic solvents NOTE Many medical and industrial charts contain these chemicals Do NOT use mounting forms pressure sensitive tapes or labels containing solvent based adhesives Use only mounting forms and pressure sensitive tapes made with starch or water based adhesives If these precautions are followed the ECG tracings should survive for the paper s expected lifespan If the tracings show any signs of fading or deterioration the customer must notify GE Healthcare promptly MAC 5500 MAC 5500 HD 2046275 016A Transmitting ECGs The MAC system can transmit ECGs to other MAC systems a MUSE CV system or a PC using any of the following methods depending on which options have been purchased Modem Manual Line Serial Line MUSE Network Ethernet Line Wireless Most methods transmit ECGs in GE Healthcare s Hilltop format but you can also choose to transmit ECGs in XML format The MAC system can be configured to transmit ECGs during an ECG test However you can also manually transmit stored ECGs at any time This chapter explains how to manually transmit ECGs For inform
106. ed persons from editing or deleting ECG measurements The password must be entered to access these functions Enter a 6 character password The default password is OVREAD Keep track of all assigned passwords Prevents unauthorized persons from accessing the system The password must be entered to use the system Enter a 6 character password By default the password is blank Keep track of all assigned passwords Determines where the ECGs are automatically stored To store to internal storage select No e To store to an SD card select Yes NOTE Any ECGs that are in internal memory storage will not be accessible when switching to SD card storage Be sure that they have been printed and or stored before switching to SD card storage only When Yes is selected for this option an SD card must be inserted in the SD card slot before performing many of the procedures described in this manual Data access speeds may vary depending on the SD card capacity and manufacturer This may affect the time required to read or write ECG records and other information to the SD card For more information on SD cards refer to Chapter 13 Using an SD Card d complete the fields described in the following table Determines whether you must enter the Patient ID before an ECG can be recorded e Select Yes to require the ID Select No to make the ID optional Determines the maximum length of the Patient ID It must match the same l
107. ed signal quality e Product discoloration Metal part corrosion e Brittle wires and connectors Reduced cables and leadwires life MAC 5500 MAC 5500 HD 165 Maintenance Cautions 166 Unit malfunction e Voided warranty Use the following procedure to clean and disinfect the cables and leadwires 1 2 Remove cables and leadwires from the device or system before cleaning Use care in cleaning leadwires to prevent pulling the long wires from the connector ends Metal connections can be pulled away from the connectors To clean wipe with a lightly moistened cloth Use a mild soap and water solution to moisten the cloth Do NOT use any of the following cleaning products or products that contain the same active ingredients and solutions which are known to cause the problems previously listed Sani Cloth Wipes e Ascepti Wipes HB Quat e Clorox Wipes they do not contain bleach Over the counter detergents such as Fantastic Tilex and so on To disinfect wipe with a soft lint free cloth moistened with an appropriate disinfectant Use the following solutions as recommended in the APIC Guidelines for Selection and Use of Disinfectants 1996 e Sodium hypochlorite 5 2 household bleach minimum 1 500 dilution minimum 100 ppm free chlorine and maximum 1 10 dilution e Any sodium hypochlorite wipe product that meets the previous guidelines can be used Observe the following guide
108. eed x1 Speed x3 Grade Not used Blood Pressure Determines how the blood pressure will be entered into the system Options are e Manual e Ergoline Ergometer e Suntech e Nipon Colin NOTE If using the Suntect blood pressure device select the Eregoline emulation mode on the device Refer to the Suntech s operators manual for details 154 MAC 5500 MAC 5500 HD 2046275 016A System Setup Inputs Outputs cont d Hi Res 2046275 016A TTL Output Determines how the TTL output will be used Options are Not Used e QRS Detect e BP Prompt NOTE If selecting any of the external blood pressure devices the TTL output must be configured to provide a QRS Trigger that meets the specifications of the blood pressure device See the blood pressure device operators manual for TTL trigger specifications Polarity Determines the polarity of the TTL Output Options are Positive e Negative Width Defines the width of the TTL Output signal in milliseconds Enter a value from 4 to 48 Delay Defines the delay in milliseconds for the TTL Output QRS detector signal Enter a value from 0 to 100 QRS Beep Determines whether the system beeps for each QRS complex Select On to enable the beep To configure the settings for the Hi Res option select System Setup Hi Res and complete the fields described in the following table Hi Res Settings Analysis Filter Determines which analysis filter to use Options are
109. eee 100 Editing Interpretive StateMents ccsssccesssssececsssccesessseeceesseeeeeeseee 101 Deleting ECGs and Orders Deleting ECOS ii ei 103 Deleting Orders iiie en e A t 104 Using an SD Card Supported SD Cards oi ep e eret eee pnt ide ex E Dee re a ee pie adn 107 Preparing the SD Card MS 108 MAC 5500 MAC 5500 HD 5 14 Locking and Unlocking the SD Card 0 ke 108 InsertingiandEjecting the SD Cord 45x5 05d casas van debia de 108 Formatting Kino Ko PAE iain dial odas 108 Managing Files on the SD Card E ereke keke ekere k kek 109 Displaying Stored EGGS metia lates di nd 109 Copying Files to the SD Cardis siepe bt pr e Stat e ded etr gent 109 Restoting Files frorn the DCine o e a ne catis 110 Saving Fils in XML FOrTriat ioo e re ese e the tere d ena 110 Updating Software from the SD Card esee 111 System Setup System Setup Hierqrc hy uh erkeke keke ee keke neken nen HARE eoa ias 113 Process OVER 115 Setting Up Automatic Tasks eese eke kek ek ke KK KRE KEKE 116 Setti g Up Power Up FUNCOM s osos He EROR ide ure wn KARA Wa 116 Setting UP ECG PI totem dead de el ml al e er dado ad i bee aa 116 Setting Up Resting ECG Report Printing oooooococccccccncocococococononcncncncorororonono 117 Setting Up Automatic ECG Storing sss eee ener 117 Setting Up Automatic ECG TTONSMISSION
110. ength of the Patient ID in the MUSE CV system to which the MAC system communicates Enter any number from 3 16 MAC 5500 MAC 5500 HD 121 System Setup Patient Questions cont d Age Determines the method the system uses to enter the patient s age Select one of the following values Date of birth Select this option to enter the patient s birth date in day month year format The system will calculate the patient s age Age in years Select this option to enter the patient s age in years months weeks days or hours Your selection also affects the way in which the patient s age is printed on the report when data is transferred from a card reader or order manager Gender Determines whether the system will prompt you for the patient s gender Select Yes to prompt for gender Height Determines whether the system will prompt you for the patient s height Select Yes to prompt for height Weight Determines whether the system will prompt you for the patient s weight Select Yes to prompt for weight Height Weight in Determines the unit or measurement in which height and weight are measured e Select in Ib to measure the height in inches and weight in pounds Select cm kg to measure the height in centimeters and the weight in kilograms Determines whether the system will prompt for the patient s race Select Yes to prompt for race NOTE Race has been acknowledged by the medical profession as useful t
111. ential of an electrode pair does not exceed 100mv 5 seconds after a defibrillation discharge Accuracy Of the Input Signal Reproduction Overall System Error meets AAMI EC11 3 2 7 1 Overall System Error is between or within 5 e Frequency Response meets AAMI EC11 3 2 7 2 methods A and D Frequency response is between or within 10 between 0 67 and 40 Hz and between 0 and 10 for 20 ms 1 5 mV triangular input Modulating Effects in Digital Systems This device uses digital sampling techniques that may produce some variation in amplitudes of Q R and or S waves from one heart beat to the next which may be particularly noticeable in pediatric recordings If this phenomenon is observed the clinician should be aware that the origin of amplitude variations is not entirely physiologic For measuring voltages of Q R and S waves it is advisable to use the QRS complexes with the largest deflection of the particular waves Installation and Connection If the installation of this equipment in the USA will use 240 V rather than 120 V the source must be a center tapped 240 V single phase circuit Contact GE Healthcare for information before connecting any devices to this equipment not recommended in this manual Parts and Accessories 10 To ensure patient safety use only parts and accessories manufactured or recommended by GE Healthcare Parts and accessories used must meet the requirements of the applicable IEC 601 s
112. entifies the trigger value in milliseconds Corrected QT intervals whose duration meet or exceed this value will trigger the notification STEMI detection STEMI detection enables the notification for ECGs in which an ST segment elevation myocardial infarction is detected Select Yes to enable STEMI notifications 144 MAC 5500 MAC 5500 HD 2046275 016A System Setup Critical Values Notification Setup cont d Ischemia detection Ischemia detection enables the notification for ECGs in which ischemia is detected Select Yes to enable ischemia notifications AV Block detection AV Block detection enables the notification for ECGs in which an AV block is detected Select Yes to enable AV Block notifications Arrhythmia Arrhythmia detection enables the notification for ECGs in which detection an arrhythmia is detected Select Yes to enable arrhythmia notifications NOTE For more information on the critical values for STEMI detection ischemia detection AV block detection or arrhythmia detection refer to the 12SL Physician s Guide Saving Critical Values to SD Card Use the following procedure to save your critical value notification settings to an external SD card You can use the card to restore the notification settings in the case of a system failure You can also use the card to quickly configure other systems 1 Configure your Critical Values Notifications Refer to Notifications Setup on page 144 for details 2
113. equently the intensity of the exercise should change Select Yes if you want the ergometer workload or treadmill speed and grade to change every 6 seconds e Select No if you want the ergometer workload or treadmill speed and grade to change with each stage change Name of PRETEST Determines the name of the pretest phase as it will appear phase on your reports The pretest phase warms up the patient and acquires baseline values Name of EXERCISE Determines the name of the exercise phase as it will appear on phase your reports The exercise phase exerts the patient and acquires target values Name of RECOVERY Determines the name of the recovery phase as it will appear on phase your reports The recovery phase cools down the patient and acquires peak values Name of FINAL phase Determines the name of the final phase as it will appear on your reports The final phase prints the final report Peak report style Determines which report to print at the exercise peak at the beginning of the recovery phase Options include No report 12 15 Ld Medians 5 Second Rhythm Each of a protocol s four phases may consist of several stages that slowly adjust the intensity of the exercise over a period of time The following table lists the stage fields that you can modify Stage Identifies the name of the stage Each phase can have multiple stages except for Test End which allows only one stage Duration Sets the length of the stage in minute
114. equire one of the following adapters to connect to electrodes Connecting Peripherals You should connect any of the following peripheral devices to the MAC system before powering it on 40 MAC 5500 MAC 5500 HD 2046275 016A System Overview Connecting the LAN Option See the LAN Option for MAC Resting ECG Systems Installation and Troubleshooting Guide for information about connecting the LAN option Connecting the Modem Option See the Field Service Manual for information about mounting and connecting the modem option Connecting the MobileLink Wireless Option See the MobileLink Installation and Troubleshooting Guide for information about mounting configuring and connecting the wireless option Connecting External Exercise Devices The following table identifies the optional exercise devices that can be connected to the MAC system and the ports through which they connect Series T2000 treadmills e SunTech Tango blood pressure device e Colin STBP 780 blood pressure device or Ergoline 900 900L integrated blood pressure device NOTE Before using external devices the system must be properly set up see Chapter 14 System Setup and exercise protocols must be properly defined see Chapter 7 Editing Protocols ANA TTL Port The Ergoline 800 ergometer The Ergoline 900 ergometer NOTE Other bicycle ergometers and treadmill models with an analog port can be connected to the analog outpu
115. er 0 the report will not print Interpretation with Interpretation without Tic marks Medians times 2 Auto gain Auto shift Confirmation text Available for each report format except the Expanded Median report this field determines how many copies of the report without 12SL interpretation will print You can enter any value from O to 10 If you enter 0 the report will not print Available only for the Expanded Median report this field determines whether tic marks will print on the report Select Yes to include tic marks Available only for the Expanded Median report this field determines whether the medians will be doubled Select Yes to double the medians Available only for the 2 by 5s Simult report this field determines whether the report will apply the auto gain filter Select Yes to apply the auto gain filter Available only for the 2 by 5s Simult report this field determines whether the report will apply the auto shift filter Select Yes to apply the auto shift filter Available only on the report for unconfirmed resting ECGs this field contains the text that prints on the report to identify the ECG as unconfirmed Options are Unconfirmed and Reviewed by The following table lists the available formats for confirmed ECGs and identifies the type of ECG for which each format is available Unconfirmed Reports Formats Bes AA wsom v Too wsm id abysesimut Y TT Oo Tooo o yw RA
116. erface window opens with a list of local orders displayed Select Delete Orders The available options on the menu change To cancel without deleting any orders select Cancel You return to the opening set of menu options To delete one or more specific order do the following a Press Select The cursor moves to the list of orders b Select the order s to delete To select an order highlight it and press Return or the arrow pad button Select as many orders as necessary Use the Page Up function key Page Down function key and arrow pad to navigate through the list of orders NOTE If you select an order that has not been processed a window opens to ask whether you want to delete the unprocessed order Select Yes to continue with the unprocessed order Select No to cancel the selection c When all the orders are selected select Delete The message Are you sure you want to delete the orders opens d Doone ofthe following To delete the selected orders select Yes The orders are deleted and you return to the opening set of menu options To cancel the deletion select No The orders are not deleted and you return to the opening set of menu options To delete all the orders select Delete All The message Are you sure you want to delete the orders opens Do one of the following To delete all the orders select Yes The orders are deleted and you return to the opening set of menu options e To cancel the deleti
117. eries safety standards and or the system configuration must meet the requirements of the IEC 60601 1 1 medical electrical systems standard The use of ACCESSORY equipment not complying with the equivalent safety requirements of this equipment may lead to a reduced level of safety of the resulting system Consideration relating to the choice shall include use of the accessory in the patient vicinity and evidence that the safety certification of the accessories has been performed in accordance to the appropriate IEC 60601 1 and or IEC 60601 1 1 harmonized national standard The following sections identify the parts and accessories approved for use with this device Not all items have been approved for use in all countries Please check with your local GE Healthcare representative for country availability MAC 5500 MAC 5500 HD 2046275 016A Introduction Electrodes The following non polarizing electrodes have been approved for use with this device Electrodes 21714401 Suction Bulb Electrode Thorax Electrode 42101600 Blue Suction Bulb 91920031 SilverTRACE ECG Electrodes Soft P55MO foam round wet gel 25 pouch 200 box 2014780 001 SilverTRACE ECG Electrodes Soft Stress PS50MO foam round wet gel 30 pouch 300 box 2014783 001 Silver TRACE ECG Electrodes Window P50TR clear tape round solid gel 30 pouch 300 box 2014784 001 Silver TRACE ECG Electrodes Window P50TR clear tape round solid gel 5 strip 300 box
118. eviewer information and press Return to display the ECG measurements to edit f you select Hi Res Measurements the Onset and Offset softkeys are displayed Press the appropriate softkey to display the associated Hi Res measurements to edit Select the measurement s to be edited and type the appropriate value When you are done press Return Continue to edit measurements as necessary 10 When you are done press Return twice The following message is displayed Select Store to save the edited file This will replace the original file Select Cancel or press Esc to discard the changes made to the current file 11 Select Store to save the edited file 100 MAC 5500 MAC 5500 HD 2046275 016A Editing ECGs Editing Interpretive Statements The MAC system automatically adds interpretive statements to ECG reports The system allows you to edit these statements as you deem necessary You can add modify join and delete statements You must enter an overreader s password and reviewer information before you can edit the statements This prevents unqualified persons from adjusting the statements 1 2046275 016A Press File Manager A list of ECG reports opens Press Select The cursor is displayed on the screen Highlight the ECG report to edit Press Edit to open a list of editing options Select Diagnostic Statements You are prompted to enter the overreader password Enter the overreader password and press Return
119. f the screen This counts down as it acquires 10 seconds of ECG data A Critical Test Result window opens This occurs only if a the optional Critical Values feature has been enabled and configured and b one or more of the critical values has been met Press MAC 5500 MAC 5500 HD 2046275 016A Recording an ECG Continue to close the message and continue See Critical Values Setup on page 143 for more information on configuring Critical Values The ECG report prints This occurs only if the report has been configured to print automatically See Chapter 14 System Setup for more information The Saving ECG window flashes on the screen This occurs only if a report has been set to save automatically See Chapter 14 System Setup for more information The ECG is transmitted to the MUSE CV system This occurs only if the system has been set up to transmit ECGs automatically See Chapter 14 System Setup for more information To print the ECG press the Print To save the ECG select Store This stores the ECG either to internal memory or to an external SD card depending on whether the SD Card Storage Only option is enabled in Miscellaneous Setup NOTE This option is available only if the system was not configured to save the file automatically After the ECG has been stored it can be transmitted to a MUSE system If the system is set up to automatically transmit data the message Establishing netw
120. f the machine uses error correction dentifies the type of modem being used Valid options are Autodetect e Internal e External 124 MAC 5500 MAC 5500 HD 2046275 016A System Setup Transmission Settings cont d Two second pause Indicates you can create a two second pause by entering a comma in a telephone number This will force the modem to wait for a dial tone before dialing This is useful when accessing an outside line the pause allows time to connect to the outside line before dialing the telephone number For example if you enter have to dial 9 to access an outside line entering a phone number of 9 3216788 will pause for two seconds after dialing 9 for the outside line and before dialing the telephone number 3216788 Phone number Identifies the telephone numbers you most frequently transmit to Enter from one to six telephone numbers Type a location name to identify each telephone number Identifies the receiving device type Valid options are e MUSE NETWORK Select this option when transmitting to a MUSE CV system or another MAC system Fax Machine Select this option when transmitting to a facsimile machine NOTE When faxing a batch of ECGs the system does not transmit all the ECGs in the batch in a single fax Instead it faxes the first ECG hangs up redials and faxes the next ECG This is its normal mode of operation Use IR for serial line Determines whether the system will use the
121. fer to Entering Data on page 50 for information on how to enter data 4 When you are done press Return The order is saved the entry window closes and you return to the Order Manager Interface window The new order is now available 5 Proceed to Selecting and Completing Orders on page 69 Selecting and Completing Orders After you have orders on the system whether they were downloaded from a MUSE CV system or created manually use the following procedure to select and complete them 1 Choose Select The cursor moves to the list of available orders 2 Select the order you want to use and press Return A window opens with the order details 3 Doone of the following To select a different order select Cancel The detail window closes and you return to the Order Manager Interface e To use the selected order select Continue The appropriate ECG test window opens with the selected order The Patient Information window opens with the information from the order 4 Enter or correct the patient data 2046275 016A MAC 5500 MAC 5500 HD 69 Entering Patient Information 70 MAC 5500 MAC 5500 HD 2046275 016A Recording an ECG The method for recording an ECG varies depending on the type of ECG to be recorded This chapter describes how to record the following ECG types e Standard ECGs e Signal Averaged ECGs Master s Step ECGs Some methods may not be available on your system depending on which options ha
122. field Race is one of these optional fields Race has been acknowledged by the medical profession as useful to analyze some pathologies You should be aware that in some jurisdictions the processing of data revealing an individual s racial origin is subject to legal requirements such as obtaining the patient s prior consent If you elect to collect this type of data it is your responsibility to ensure that you comply with all applicable legal requirements Responsibility of the Manufacturer GE Healthcare is responsible for the effects of safety reliability and performance on GE supplied hardware only if the following conditions are met e Assembly operations extensions readjustments modifications or repairs are carried out by persons authorized by GE Healthcare e The electrical installation of the relevant room complies with the requirements of the appropriate local state and other government regulations The equipment is used in accordance with the instructions for use Responsibility of the Purchaser Customer The customer is responsible for providing appropriate desks chairs electrical wall outlets network connections analog phone lines and for locating any of the system components described in this manual in compliance with all local state and national codes Service Information This section provides information pertaining to the maintenance and servicing of the device Familiarize yourself with this information
123. formation e Test Information e Medication e ACI TIPI Chest or Left Arm Pain The correct fields for the selected ECG open 6 Make the necessary corrections and press Return 7 Continue to edit demographic information as necessary 8 When you are done press Return twice The following message is displayed MAC 5500 MAC 5500 HD 99 Editing ECGs Select Store to save the edited file This will replace the original file Select Cancel or press Esc to discard the changes made to the current file 9 Select Store to save the edited file Editing ECG Measurements Only overreaders can modify ECG measurements You must enter an overreader s password and reviewer information before you can edit the measurements This prevents unqualified persons from adjusting the ECG reading 1 Press File Manager A list of ECG reports opens 2 Press Select The cursor is displayed on the screen Highlight the ECG report to edit 4 Press Edit to open a list of editing options 5 Select one of the following options ECG Measurements This allows you to edit resting pediatric or vector loop measurements e Hi Res Measurements This allows you to edit averaged signal measurements You are prompted to enter the overreader password 6 Enter the overreader password and press Return One of two things happens depending on which option was selected e If you selected ECG Measurements the reviewer information fields open Enter the r
124. gain and filter for the writer Adjust the settings as appropriate and select Return To change the leads select Leads MAC 5500 MAC 5500 HD 77 Exercise Stress Testing The Rhythm Leads window opens This window allows you select the lead groups to use in the test check lead connections and check lead placement Highlight the appropriate option and press Return 5 After the settings have been adjusted select Select Proto A list of available stress test protocols opens 6 Select the desired protocol The selected test begins Refer to the following sections for instructions on how to proceed during each phase of the test Pretest Phase The pretest phase differs depending on the stages configured in each protocol Commonly used stages are e Supine e Standing Hyperventilating If the system is configured to manually take blood pressure measurements the system will beep and display a message when it is time to take the blood pressure If the system is configured to take blood pressure measurements automatically the system will take the measurements as appropriate You can use the Protocol Editor to configure the protocol to take blood pressure measurements manually or automatically Refer to Chapter 7 Editing Protocols A set of medians is saved at the end of the Pretest phase as the baseline medians 1 On the stress keypad press 12 ld to acquire and print a baseline ECG 2 Press Pretest to advance to the
125. h ECG you can configure the e leads used for the reports report formats used for confirmed ECGs and report formats used for unconfirmed ECGs In addition you can configure the extra leads used by the 15 Lead ECG reports and the settings for the Vector Loops reports Report Leads 2046275 016A The Report Leads settings allow you to configure the following values e the leads used for each standard channel e the rhythm reporting method e the leads used for each rhythm report lead group e the autorhythm lead group e the extra leads used by the CGR and RMR reports e the leads used by the Swedish rhythm report The settings are essentially the same for each ECG type although the available values for each setting may differ depending on the ECG type Use the following instructions to select the correct Report Leads for each report type Resting ECG Report System Setup gt ECG gt Resting ECG Reports gt Report Leads Pediatric ECG Report System Setup gt ECG gt Pediatric ECG Reports gt Report Leads 15 Lead ECG Report System Setup gt ECG gt 15 Lead Reports gt Report Leads e Vector Loops ECG Report MAC 5500 MAC 5500 HD 135 System Setup System Setup gt ECG gt Vector Loops ECG Reports gt Report Leads Report Leads Standard leads Defines which leads will print for each channel When you change a channel s lead the new lead prints on all ECG reports including the channel You can defi
126. h or serious injury CAUTION Indicates a potential hazard or unsafe practice which if not avoided could result in minor personal injury or product property damage Safety Messages The following messages apply to the product as a whole Specific messages may also appear elsewhere in the manual WARNING ACCIDENTAL SPILLS If liquids enter a device take the device out of service and have it checked by a service technician before it is used again To avoid electric shock or device malfunction liquids must not be allowed to enter the device WARNING BATTERY OPERATION If the integrity of the protective earth conductor is in doubt operate the unit from its battery WARNING CABLES To avoid possible strangulation route all cables away from the patient s throat 24 MAC 5500 MAC 5500 HD 2046275 016A Introduction WARNING CONNECTION TO MAINS This is class equipment The mains plug must be connected to an appropriate power supply WARNING DEFIBRILLATOR PRECAUTIONS Do not come into contact with patients during defibrillation Otherwise serious injury or death could result Patient signal inputs labeled with the CF and BF symbols with paddles are protected against damage resulting from defibrillation voltages To ensure proper defibrillation protection use only the recommended cables and leadwires Proper placement of defibrillator paddles in relation to the electrodes is required to ens
127. icts this device to sale by or on the order of a physician Recording ECGs During Defibrillation 2046275 016A This equipment is protected against the effects of cardiac defibrillator discharge to ensure recovery as required by test standards The patient signal input of the acquisition module is defibrillation proof Therefore it is not necessary to remove the ECG electrodes prior to defibrillation When using stainless steel or silver electrodes a defibrillator discharge current may cause the electrodes to retain a residual charge causing a polarization or dc offset voltage This electrode polarization will block acquisition of the ECG signal To avoid this condition use non polarizing electrodes which will not form a dc offset voltage when subjected to a dc current such as silver silver chloride types if there is a situation where there is a likelihood that a defibrillation procedure will be necessary MAC 5500 MAC 5500 HD Introduction If polarizing electrodes are used we recommend disconnecting the leadwires from the patient before delivering the shock Electrode defibrillation recovery is the ability of the electrode to allow the ECG trace to return after defibrillation We recommend using non polarizing disposable electrodes with defibrillation recovery ratings as specified in AAMI EC12 4 2 2 4 Refer to Parts and Accessories on page 10 for a list of approved electrodes AAMI EC12 requires that the polarization pot
128. information see Appendix A Maintenance Performance Problems This section describes some of the more common performance problems with the MAC system Typically these result from faulty peripherals configuration issues or operator error Unacceptable Noise Levels If the acquired ECG data displays unacceptable noise levels do the following Verify proper electrode placement 2046275 016A MAC 5500 MAC 5500 HD 177 Troubleshooting Slipped or misplaced electrodes can result in faulty readings Refer to Preparing the Patient s Skin on page 54 Verify proper electrode application Perspiration excessive hair lotions and dead skin cells must be removed from the electrode site Refer to Electrode Placement on page 55 Check for defective or expired electrodes Verify the electrodes have not exceeded their shelf life Check for defective broken or disconnected leadwires Replace or reconnect leadwires as necessary Check the patient s position The patient should remain motionless during the acquisition of a resting ECG ACI TIPI Report Does Not Print If the ACI TIPI report does not print when expected do the following Verify ACI TIPI is enabled Refer to Setting Up ACI TIPI Interpretation on page 118 Verify the selected report format includes Interpretation Reports without interpretation will not include ACI TIPI information Verify the ACI TIPI information was entered for the patient AC
129. ing the battery compartment in a manner other than that described in the following procedure may cause the unit to malfunction and void the warranty The battery compartment is not waterproof Make certain fluids do not enter the electronics through the air holes in the battery compartment floor Remove the battery from the battery compartment Clean the device with a gauze pad or cloth lightly moistened with one of the following agents e Water e Soap MAC 5500 MAC 5500 HD 169 Maintenance 3 Use a cloth lightly moistened with distilled water to rinse away the cleaning solution Make certain that moisture does not enter the electronics area below the battery compartment floor 4 Dry thoroughly with a lint free cloth and allow the battery compartment to air dry completely prior to closing the compartment door Paper Maintenance Proper paper maintenance ensures optimum ECG printouts Paper maintenance includes e Setting the correct paper size Loading the paper Setting the Correct Paper Size The MAC system can accommodate standard US Letter and A4 fanfold thermal ECG paper To ensure that the paper feeds correctly you must adjust the paper guide 1 Open the MAC writer drawer 2 170 MAC 5500 MAC 5500 HD 2046275 016A Maintenance 3 To set the tray for standard US Letter paper slide the guide toward the front of the device 4 You are now ready to load your paper Loading the Paper Us
130. ings for exercise tests log on to the System Setup screen select Exercise Test gt Writer Setup and complete the fields described in the following table Writer Setup Determine the writer s default speed in millimeters per second Determines the writer s default gain setting in millimeters per millivolts For example the setting 10 5 displays limb leads at 10 mm mV and precordial leads at 5 mm mV Determines the writer s default filter setting The default is 150 Hz Arrhythmia Doc Determines whether a report will print whenever an arrhythmia occurs during the exercise test Tic marks Enables tic marks on the E J and J measurement points The value for the J point is set using the Post J field ST Measurements Enables ST Measurements on the display and printout Post J Defines the location in milliseconds after the J point where the ST Measurement is to be taken Enter a value from 0 to 200 Enables or disables the writer for the exercise test Exercise Reports You can configure the reports generated for 12 Lead Exercise Stress ECGs 15 Lead Exercise Stress ECGs and Final Report For each ECG you can configure the e leads used for the reports formats used for the reports and e settings for the final report In addition you can configure the extra leads used by the 15 Lead Exercise report Report Leads The Report Leads settings allow you to configure the following values e the leads used for each stand
131. iteria when setting the length e value can be from 0 to 19 should equal the visit length from the ADT system The patient s first name Enter the field s Offset and Length Be aware of the following criteria when setting the length e value can be from 0 to 10 should equal the length from the MUSE CV system with which the MAC system communicates NOTE The MAC system does not support long names if the MUSE system uses long names this field should be set to its maximum value The patient s last name Enter the field s Offset and Length Be aware of the following criteria when setting the length value can be from 0 to 16 should equal the length from the MUSE CV system with which the MAC system communicates NOTE The MAC system does not support long names if the MUSE system uses long names this field should be set to its maximum value he year the patient was born Enter the field s Offset and Length The length must be set to 4 The month the patient was born Enter the field s Offset and Length The length must be set to 2 The day the patient was born Enter the field s Offset and Length The length must be set to 2 The patient s gender Enter the field s Offset and Length The length must be set to 1 MAC 5500 MAC 5500 HD 2046275 016A Creating Bar Codes and Magnetic Cards Bar Code Reader and Magnetic Card Reader Configuration Fields cont d Enable data Determines whether the s
132. ives of the patient user and bystanders When disconnecting the device from the power line remove the plug from the wall outlet before disconnecting the cable from the device otherwise there is a risk of coming into contact with line voltage by inadvertently introducing metal parts in the sockets of the power cord Devices may be connected to other devices or to parts of systems only after making certain that there is no danger to the patient operators or environment as a result Standards IEC 60601 1 1 EN60601 1 1 must be complied with in all cases WARNING SITE REQUIREMENTS Improper placement of the device and or accessories may result in a hazard to the patient operator or bystanders Do not route cables in a way that they may present a stumbling hazard For safety reasons all connectors for patient cables and leadwires are designed to prevent inadvertent disconnection should someone pull on them For devices installed above the patient adequate precautions must be taken to prevent them from dropping on the patient WARNING TREADMILLS Avoid rapid changes in treadmill speed and or grade during a stress test CAUTION PROPER LEADWIRE CONNECTION Improper connection will cause inaccuracies in the ECG Trace each individual leadwire from its acquisition module label to the colored connector and then to the proper electrode to ensure that it is matched to the correct label location CAUTION ACCESSORIES
133. l Keyboard the valid options are Manual None For more information on configuring the card reader or the bar code reader refer to Setting Up a Card Reader on page 156 and Setting Up a Bar Code Reader on page 158 130 MAC 5500 MAC 5500 HD 2046275 016A System Setup Setting Up ECGs This section describes the following ECG settings ECG Acquisition e ECG Analysis e Patient Questions Writer Setup e ECG Reports e Analog Outputs e CT Data Guard e Critical Values Setup ECG Acquisition 2046275 016A To configure ECG acquisition log on to the System Setup screen select ECG ECG Acquisition and complete the fields described in the following table ECG Acquisition Baseline roll filter Removes baseline sway The higher the settings the more the filter smooths out wandering baseline This filter does not distort the ST segment displays on the ECG reports AC filter Removes AC line artifacts Disable auto gain Disables the check for out of range ECG gain Select No to enable check the auto gain check If enabled the system will display a prompt if the gain of the recorded ECG is either too high or too low allowing the user to manually adjust the gain Disable lead off Disables the check for leads that are disconnected Select No to check enable the check If enabled the system will display a message if it detects any disconnected leads Pacemaker pulse Enhances the system detecti
134. licable only if the Exercise option has been enabled In addition to the standard electrodes apply one electrode on the sternum A1 and one in location V5R C5R A2 It is recommended that arm electrodes be placed on the patient s torso just under the clavicles CM5 CC5 ML Lead Placement In the fifth intercostal space in the right anterior axillary line VSR C5R 60 MAC 5500 MAC 5500 HD 2046275 016A Preparing the Patient CM5 CC5 CH Lead Placement 2046275 016A Mid sternum at the second intercostal space VSR C5R In the fifth intercostal space in the right anterior axillary line On either side of the neck or anywhere above the shoulders Hz MAC 5500 MAC 5500 HD 61 Preparing the Patient 62 MAC 5500 MAC 5500 HD 2046275 016A Entering Patient Information The first step in conducting any ECG test resting pediatric 15 lead vector loops or exercise is to identify the patient Patients can be identified by manually entering the data by bar code scanner or magnetic card reader or by retrieving it from a MUSE CV system This chapter describes the available methods for entering patient information and order information into the system Manually entering patient information Reading a patient ID card Scanning a patient bar code Receiving orders from a MUSE CV system Manually entering orders Some methods may not be available on all systems depending on which options have been purchased
135. lines when cleaning and disinfecting cables and leadwires Do NOT immerse either end of a cable or leadwire connector Immersing or soaking the connector ends may corrode metal contact ends and affect signal quality e Do NOT let fluid pool around connection pins If this happens blot dry with a soft lint free cloth Dry the cable and leadwires thoroughly with a dry lint free cloth and let air dry for at least 30 minutes DO NOT use excessive drying techniques such as oven forced heat or sun drying NOTE Drying times may vary based on the environmental conditions Follow the cleaning instructions exactly e Wring excess disinfectant from wipe before using MAC 5500 MAC 5500 HD 2046275 016A Storage Maintenance Never immerse the device cables or leadwires in any liquid as this may corrode metal contacts and affect signal quality Do not allow fluid to pool around connection pins If this happens blot dry with a soft lint free cloth Never use conductive solutions or solutions that contain chlorides wax or wax compounds to clean the device cables or leadwires Never use solutions or products that contain any type of Ammonium Chloride such as but not limited to Dimethyl Benzyl Ammonium Chloride Quaternary Ammonium Chloride solutions e Abrasive cleaners or solvents of any kind e Acetone e Ketone e Betadine e Alcohol based cleaning agents e Sodium salts Never autoclave or stea
136. ly once and the card reader remains attached and ready for use 1 Connect the magnetic card reader to port A on the back panel of the system For information on the system ports refer to Back Panel on page 35 Configure the card reader For information refer to Setting Up a Card Reader on page 156 Reading a Patient ID Card After the card reader has been set up use the following procedure to read a patient s ID card 2046275 016A 1 For each new patient select Patient Data The message Slide the Patient ID card or Slide the Visit Number card opens depending on system configuration Slide the magnetic card through the magnetic card reader making sure the magnetic strip is facing the correct direction What happens next depends on your system settings The system may be set up to simply load the patient data directly from the card Or it may be set up to use either the card s Patient ID or Visit Number to retrieve orders or ADT data Orders may be retrieved from the local cart or from the MUSE system while ADT information is always retrieved from the MUSE system With this variety of options several configuration combinations are possible However even with all the potential configurations only five responses are possible e If the system is not configured to retrieve orders or ADT information or if it finds no matching records the system loads the patient information from the card and displays it in
137. ly wash the area with clean water and see a doctor Replacing Leadwire Adapters The following diagram shows how to replace the acquisition leadwire adapters 174 MAC 5500 MAC 5500 HD 2046275 016A Maintenance IN 2046275 016A MAC 5500 MAC 5500 HD 175 Maintenance 176 MAC 5500 MAC 5500 HD 2046275 016A Troubleshooting The following sections identify some of the more common problems with the MAC system and list their potential causes and solutions If this information cannot resolve your issue contact GE Healthcare Technical Support General Troubleshooting Guidelines If the system is not working properly save time troubleshooting by asking these basic questions e s the unit turned on Have there been any changes in the use location or environment of the equipment that could cause the failure e Has the equipment s hardware or software been modified s operator error the cause of the problem Try to repeat the scenario exactly and compare that to the proper operation of the equipment described in the manual s the battery installed When connected to an AC wall outlet does the green AC power light glow e Is the writer door closed Visual Inspection A thorough visual inspection of the equipment can save time Items such as disconnected cables or missing hardware can frequently cause symptoms and equipment failures that may appear to be unrelated and difficult to track For additional
138. m clean the device cables or leadwires Do not use until thoroughly dry Store cables and leadwires by hanging them vertically in a dry well ventilated area Do NOT coil leadwires or cables around the device Cleaning Disinfecting and Storing Handheld Devices In addition to keeping the MAC system leadwires and cables clean and in good repair it is important to keep the associated acquisition modules clean and disinfected as well This section provides instructions for cleaning disinfecting and storing the acquisition modules to extend their life and protect patients Cleaning and Disinfecting Acquisition Modules Proper cleaning and disinfecting prolongs the life of acquisition devices Failure to use the proper cleaning solutions or to follow proper procedures can result in the following 2046275 016A Appearance of waveforms when not connected to a patient resulting in false alarms instead of lead failure alarms Brittle and cracked device case Melting dulling or distortion of the case Total device failure requiring replacement Unit malfunction Voided warranty MAC 5500 MAC 5500 HD 167 Maintenance Cautions 168 Use the following procedure to clean and disinfect the cables and leadwires 1 Remove cables leadwires and batteries from the device before cleaning Make sure to firmly close the battery door after removing the batteries To clean wipe with a lightly moistened cloth Use a mild soap an
139. m is now ready to receive ECGs Refer to Transmitting ECGs Locally on page 92 for instructions on setting up the other MAC system to transmit ECGs locally 3 After all the ECGs have been received select Cancel to take the system out of receiving mode 4 Select Main Menu Receiving ECGs from a MUSE CV System If you purchased the MUSE CV option you can receive ECGs from any MUSE CV system Receiving ECGs from another MAC system is passive you receive whatever ECGs the other MAC system chooses to send Receiving ECGs from a MUSE CV system however is active you select the ECGs to receive You can receive ECGs from a MUSE CV system using any of the following methods LAN This is a standard method available on all MAC systems Before receiving ECGs via LAN connect your MAC system to the LAN via its Ethernet port e Modem 96 MAC 5500 MAC 5500 HD 2046275 016A 2046275 016A Receiving ECGs This is a purchased option Before receiving ECGs via modem connect your modems as described in Receiving ECGs via Modem on page 95 MobileLink wireless This is a purchased option Before receiving ECGs via MobileLink connect and configure the MobileLink wireless system as described in the MobileLink Installation and Troubleshooting Guide NOTE Performance of the MobileLink wireless system may vary due to changes in RF radio frequency properties of your site or environmental conditions If you are experiencing intermit
140. mance may degrade or contamination could occur CAUTION DISPOSAL At the end of its service life the product described in this manual as well as its accessories must be disposed of in compliance with local state or federal guidelines regulating the disposal of such products If you have questions concerning the disposal of the product please contact GE Healthcare or its representative CAUTION EQUIPMENT DAMAGE Devices intended for emergency application must not be exposed to low temperatures during storage and transport to avoid moisture condensation at the application site Wait until all moisture has vaporized before using the device CAUTION ELECTRIC SHOCK To reduce the risk of electric shock do not remove cover or back Refer servicing to qualified personnel CAUTION OPERATOR Medical technical equipment such as this electrocardiograph system must only be used by persons who have received adequate training in the use of such equipment and who are capable of applying it properly CAUTION POWER REQUIREMENTS Before connecting the device to the power line check that the voltage and frequency ratings of the power line are the same as those indicated on the unit s label If this is not the case do not connect the system to the power line until you adjust the unit to match the power source In the USA if the installation of this equipment will use 240V instead of 120V the source must be center tapped 24
141. mation 2046275 016A MAC 5500 MAC 5500 HD 21 Introduction Equipment Identification Every GE Healthcare device has a product label that identifies the product name part number manufacturing information and unique serial number This information is required when contacting GE Healthcare for support Product Label The product label is laid out in the following format Depending on the product the label may vary slightly in format but it contains the same information i hu lt Product Part Number gt lt Product Description gt SN lt Serial Nu 7 spo ww WM s MM e GE MEDICAL SYSTEMS INFORMATION TECHNOLOGIES INC 8200 WEST TOWER AVE MILWAUKEE WISCONSIN USA 5 4 Product Label Format Product part number Product description Date of manufacture in YYYY MM format Manufacturer name and address Country of origin fe Product bar code 7 Unit serial number See Serial Number Format on page 22 for more information Serial Number Format Each device has a serial number that uniquely identifies the device and provides important information about the device The serial number format is shown in the following illustration 22 MAC 5500 MAC 5500 HD 2046275 016A Introduction Serial Number Format E qeu 1 Product Code Three letter code that uniquely identifies the product line Refer to Product Codes on page 23 for more information Year Manufactured Two digit
142. millimeters per millivolts Lead 2 display Select a default value for the lead z display Sagittal plane Select a default value for sagittal plane Confirmed Reports 2046275 016A The Confirmed Reports settings allow you to configure the following values number of copies to print for each format e whether to include tic marks on the Medians Report whether to increase the median by two on the Medians Report whether to include auto gain and auto shift on the 2 by 5s Simult report The settings are the same for each ECG type except for the Resting ECG Report which includes two additional report formats 2 by 5s Simult and Pharma 4 by 2 5s Use the following instructions to select the correct Confirmed Reports for each report type Resting ECG Report MAC 5500 MAC 5500 HD 137 System Setup System Setup gt ECG gt Resting ECG Reports gt Confirmed Reports Pediatric ECG Report System Setup gt ECG gt Pediatric ECG Reports gt Confirmed Reports 15 Lead ECG Report System Setup gt ECG gt 15 Lead Reports gt Confirmed Reports Vector Loops ECG Report System Setup gt ECG gt Vector Loops ECG Reports gt Confirmed Reports The following table identifies the available report settings for confirmed ECGs Confirmed Reports Settings Interpretation with Available for each report format this field determines how many copies of the report with 12SL interpretation will print You can enter any value
143. ne the lead for channels 1 through 15 except for the Resting ECG Report which includes only channels 1 through 12 Rhythm reports Defines the data that will print on the rhythm reports Real time Prints the ECG data currently on the screen 10 sec delayed Delays the printing by 10 seconas Rhythm leads Defines the lead option for each of the six rhythm groups to determine the rhythm leads that print when you select the rhythm key within an application e Select 3 leads to define which three leads in a three lead Rhythm report print Select 6 leads to define which six leads in a six lead Rhythm report print Select All leads to display and print 10 seconds of data for 12 or 15 leads Select Lead Check to display and print real time data for each of the 12 or 15 leads Select Lead Placement to display and print real time data for each of the 12 or 15 leads and to display the chest electrode placement Autorhythm Determines the group of rhythm leads to print on the Autorhythm report RMR CGR extra Determines the rhythm lead s to print on the RMR and CGR reports rhythm leads When you change a rhythm lead the new lead prints on alll reports that include the lead For example if you select V5 for RMR CGR extra rhythm lead 1 then the V5 waveform prints on all reports that include RMR CGR extra rhythm lead 1 Swedish format Sets the rhythm lead s to print in the Swedish Format reports rhythm leads When you change
144. next pretest stage 3 If you are using a treadmill to conduct the exercise test tell the patient to place his her feet on the treadmill frame not on the belt WARNING FALLING HAZARD Severe injury can result from a fall Patients should wait until the treadmill belt is moving before stepping onto the belt Step onto the belt with one foot at a time Avoid rapid changes in belt speed WARNING PINCH POINT HAZARD Hair jewelry and loose clothing can catch in moving parts which could result in serious injury Keep these and other items away from moving parts 4 Press Start tmill to start the treadmill belt moving During the exercise test you can adjust the test in the following ways Press STOP tmill once to stop the treadmill GRADUALLY Press and hold STOP tmill to stop the treadmill belt QUICKLY 78 MAC 5500 MAC 5500 HD 2046275 016A Exercise Stress Testing e Press the emergency stop button usually mounted on the treadmill to stop the treadmill IMMEDIATELY e Press the Speed W Speed W and Grade keys to manually control the test However once you press these keys the pre programmed protocol becomes inactive you must manually control the speed and grade during the remainder of the exercise and recovery phases The following menu items are available during the pretest phase of the exercise test Patient Data Enter a patient s name ID number and so forth Enter the patient s age to allow your system
145. ng Starting O Stress Tes diiniita 77 Pretest Male o N dote 78 Exercise PHOSB N n n Dd 79 RECOVERY P T S etie a te 81 MAC 5500 MAC 5500 HD 2046275 016A 2046275 016A 10 11 12 13 Test End P J SO iii daa 81 Editing Protocols Protocol OVErVICW ccccsssccccssssscccccsssscccccsssscecesssscecccescsccccscsessecesssssescees 83 Editing or Creating Protocols eese esee eee eene eene nnne 85 Printing ECG Reports Printing Another Report s y ne denk des i sak ke sepan nea eee renes 89 Printing stored ECGS 5 oe cerent ien k sada seek a neka n R K NE i euis 89 SCORING uunc dll Kik el eee S k Re n p k nes s re diia 90 Transmitting ECGs Transmitting ECGs via Modem sccccsssssccesssccecesseccecsssececssssceeeseseeees 91 Transmitting ECGS Locally cuicos da i M SRA E e d d k k z 92 Transmitting ECGs Wirelessly eee nennen 93 Transmitting ECGs in XML FOrm dt eene eene entente KK KA A 94 Receiving ECGs Receiving ECGs from Another MAC System eene 95 Receiving ECGS MAMMA n 95 Receiving ECGS Loi A its 96 Receiving ECGs from a MUSE CV System esee eene 96 Editing ECGs Editing Demographic Information ccooocconononcccnononnccnnnonaconooonccnnonon nooo 99 Editing ECG Measurements cccssccccessscececssseccecsssccecessseeceeeseeeeens
146. ng system must be set up to receive them The following sections explain how to set up the MAC system to receive ECGs from other MAC systems via modem or locally Receiving ECGs via Modem If the modem option was purchased use the following procedure to set up your MAC system to receive ECGs via the modem Before using the following procedure make sure your modem is connect to an analog phone line as shown in the following illustrations Internal Modem External Modem 1 Select Receive to prepare the system for receiving ECG reports 2 Select Phone Line The system is now ready to receive ECGs Refer to Transmitting ECGs via Modem on page 91 for instructions on setting up the other MAC system to transmit ECGs via modem 2046275 016A MAC 5500 MAC 5500 HD 95 Receiving ECGs 3 After all the ECGs have been received select Cancel to take the system out of receiving mode 4 Select Main Menu Receiving ECGs Locally Use the following procedure to prepare the MAC system to receive ECGs locally that is from within the facility This method receives ECGs via infrared or direct connection between the two systems Before using this procedure the MAC systems must be connected via their serial ports or if using infrared positioned as shown in the following illustration 30 4 91 4 cm 1111 33 1 Select Receive to prepare the system for receiving ECG reports 2 Select Local Line The syste
147. nly ECGs that the 12SL interpretation mark as abnormal are transmitted automatically Enable ACI TIPI Determines whether ACI TIPI interpretation will be performed Available only if the ACI TIPI option has been activated Patient Questions To configure the custom patient questions to ask log on to the System Setup screen select ECG Patient Questions and complete the fields described in the following table Patient Questions Allows you to define custom patient questions Type Allows you to set the type of response for the custom patient question Valid values are Numbers and letters Allows the entry of any alphanumeric value Numbers only Allows the entry of numeric values only e Yes or No Allows only Yes and No answers 134 MAC 5500 MAC 5500 HD 2046275 016A System Setup Writer Setup To configure the writer s behavior log on to the System Setup screen select ECG gt Writer Setup and complete the fields described in the following table Writer Setup Determines the writer s default speed in millimeters per second Determines the writer s default gain setting in millimeters per millivolts For example the setting 10 5 displays limb leads at 10 mm mV and precordial leads at 5 mm mV Determines the writer s default filter setting The default setting is 150 Hz ECG Reports You can configure the reports generated for Resting ECGs Pediatric ECGs 15 Lead ECGs and Vector Loops ECG For eac
148. nt System Errors Troubleshooting The following errors may occur while you are operating this system You may be required to perform some action If you perform the recommended actions and the condition still remains contact authorized service personnel Problem The following icon appears ps The following icon flashes The following icon appears The system does not power up when operating from battery The system shuts down when operating from battery The lead disconnected message appears The following message appears MODEM ERROR The remote device is not responding Would you like to retry 2046275 016A No battery is installed in the system The battery charge is low The writer door is open The battery is fully discharged Battery is discharged The Automatic Shutdown feature is enabled Electrode s disconnected Modem is not connected If using the wireless option the client bridge is not connected or the device is out of range Wireless option only The system is not within range of an access point Ethernet option only Bad LAN connection MAC 5500 MAC 5500 HD Install a battery and connect the system to an AC wall outlet to charge the battery Refer to Battery Maintenance on page 172 Connect the system to an AC wall outlet to charge the battery Refer to Battery Maintenance on page 172 Close the writer door Refer to Paper Maintenance
149. o 32 characters long Additional Questions Determines whether the response to additional patient questions are required on each test Select Yes to require additional questions f you select Yes you can define up to five additional questions of 10 characters each For each question you must define one of the following response types Numbers and letters Allows the entry of any alphanumeric value Answers can be up to 17 characters long e Yes or No Allows only Yes and No answers CT Data Guard Data Guard Features Prevent editing of Disables editing ECG files in File Manager Select Yes to prevent records ECG editing Prevent deleting Disables the deletion of ECGs that have not been transmitted Select of untransmitted Yes to prevent the deletion of untransmitted ECGs records Enable record Enables a notification if users attempt to retransmit records that re transmit have already been transmitted to the MUSE CV system Select Yes notification to enable the notification Critical Values Setup The optional Critical Values function allows you to set up custom notifications for select ECG events The notification is displayed after the ECG has been acquired and you must acknowledge it before proceeding They also print on the ECG reports You can customize the notification text and select the events that trigger the notifications For some events you can also select the specific values that trigger the notification
150. o analyze some pathologies You should be aware that in some jurisdictions the processing of data revealing an individual s racial origin is subject to legal requirements such as obtaining the patient s prior consent If you elect to collect this type of data it is your responsibility to ensure that you comply with all applicable legal requirements Blood pressure Determines whether the system will prompt for the patient s systolic and diastolic blood pressure Select Yes to prompt for blood pressure Medications Determines whether the system will prompt you to enter any medications the patient is taking Select Yes to prompt for medications Referred by name Determines whether the system will prompt you to enter the name of the referring physician Select Yes to prompt for this information 122 MAC 5500 MAC 5500 HD 2046275 016A System Setup Patient Questions cont d CN CT Referred by number Determines whether the system will prompt you to enter the ID number of the referring physician Select Yes to prompt for this information When entering the referring physician s number enter numbers that are compatible with the MUSE CV system to which the MAC system communicates Test Indication Determines whether the system will prompt for the test reason Select Yes to prompt for the reason Patient History Determines whether the system will prompt for the patient s history Select Yes to prompt for the history Technici
151. o the System Setup screen select Exercise Test gt Miscellaneous Setup and complete the fields described in the following table Miscellaneous Setup Timeout Interval Determines how long it takes for a menu or prompt to close if it is not being used Enter a value from 15 to 600 seconds Cubic Spline Enables baseline control Event names Defines a list of event names that may be selected to label patient episodes during the stress test Reason for Defines a list of reasons that may be selected to indicate why a Termination stress test was terminated Patient Questions To configure the patient s heart rate values and questions log on to the System Setup screen select Exercise Test gt Patient Question and complete the fields described in the following table Patient Questions Max Pred HR Determines whether the patient s maximum predicted heart rate must be entered Target Heart Rate Determines whether the patient s target heart rate must be entered Enter a percentage of the maximum predicted heart rate Extra Questions Defines two additional patient questions to ask during the test For each question you must select the type of valid response Numbers and letters Allows the entry of any alphanumeric value Numbers only Allows the entry of numeric values only e Yes or No Allows only Yes and No answers 2046275 016A MAC 5500 MAC 5500 HD 147 System Setup Writer Setup To configure the writer sett
152. on select No MAC 5500 MAC 5500 HD 2046275 016A 2046275 016A Deleting ECGs and Orders The orders are not deleted and you return to the opening set of menu options To delete all the completed orders select Del Completed The message Are you sure you want to delete all completed orders opens Do one of the following To delete all the completed orders select Yes The orders are deleted and you return to the opening set of menu options To cancel the deletion select No The orders are not deleted and you return to the opening set of menu options MAC 5500 MAC 5500 HD 105 Deleting ECGs and Orders 106 MAC 5500 MAC 5500 HD 2046275 016A Using an SD Card The MAC system allows you to extend the device s storage capacity by using an external Secure Digital SD card The SD Card is also used to distribute and apply software updates The following table compares the differences between internal storage and SD card storage Be aware of these differences when selecting your storage option Internal Storage vs SD Card Storage Delete XML file when deleting corresponding ECG file Yes Memory Status Messaging 70 90 Full SD Card Full ves VA 1 System overwrites XML files with the same name Supported SD Cards 2046275 016A The system supports SD cards of the following capacity 64 MB e 128 MB e 256 MB e 512 MD 1GB e 2GB NOTE The system does NOT support SDHC High Capacity SD cards
153. on of small pacemaker pulses When enhancer enabled the system is very sensitive and should NOT be placed close to equipment that emits high frequency radiation High frequency radiation can interfere with pacemaker pulse detection and normal ECG acquisition NOTE GE Healthcare recommends that this be set to No unless it is known that the majority of this cardiograph usage will be on patients with pacemakers The pacemaker pulse enhancement can always be enabled on a per patient basis at the time of ECG acquisition within the resting ECG programs Baseline wander Enables the display a message when the system detects a warning wandering baseline Muscle tremor Enables the display of a message when the system detects a muscle warning tremor MAC 5500 MAC 5500 HD 131 System Setup ECG Acquisition cont d AC noise level Enables the system to check for powerline interference when warning recording ECGs Hookup Advisor Enables the Hookup Advisor option which monitors the quality of ECG signals for resting 15 lead pediatric vector loops and Master s Step measurements When enabled the system overrides the settings for Baseline wander warning Muscle tremor warning and AC noise level warning For more information refer to Hookup Advisor on page 71 Prompt Level Determines the level at which the Hookup Advisor prompts users regarding patient hookup quality This field is available only if Hookup Advisor is enabled
154. ore gt ACS Off This opens the ACS On Off window Select ACS On and press Return NOTE ACS is an optional feature This function key is available only if the option has been purchased and activated Refer to Option Activation on page 126 for instructions on activating this option NOTE ACS is activated on a per patient basis Settings are not retained from patient to patient it must be activated for each patient Once all the settings have been adjusted accordingly press ECG Any of the following may occur depending on your system settings TheACI TIPI Required Information window opens This occurs only if the optional ACI TIPI feature is enabled If this window opens complete the following information Age 18 40 41 50 gt 50 Gender Male Female e Chest or Left Arm Pain Select Chief Complaint if the complaint of chest pain or left arm pain is the primary reason the patient is at the hospital e Select Secondary Complaint if chest pain or left arm pain is not the primary reason the patient came to the hospital Select Not Present if the patient is not experiencing any chest pain or left arm pain or equivalent discomfort See ECG Acquisition on page 131 for information on enabling the optional ACI TIPI feature NOTE If any of the information was provided on the Patient Information screen you will not be asked for it here The message Acquiring data x sec is displayed in the upper left corner o
155. ork connection will be displayed on the screen If the system is not set up to automatically transmit data you will need to manually initiate the transmission Refer to Chapter 9 Transmitting ECGs Do one of the following To take another ECG for the same patient press Same Pat To take an ECG for another patient press Next Pat Signal Averaged ECGs 2046275 016A This is an optional method used for Hi Res and PHi Res ECGs 1 Select Hi Res or PHi Res to enable the system to record a signal averaged ECG NOTE GE Healthcare recommends a target noise level of 0 3 uV or less when recording a PHi Res ECG Select Template to initiate the signal averaged ECG recording Use the following steps to change the seed beat a Select Display b Select SelectQRS C Select a new seed beat Select Average to average the ECG data MAC 5500 MAC 5500 HD 75 Recording an ECG 5 Select Store to store the ECG data 6 You are now ready to transmit the ECG data to a MUSE system Refer to Chapter 9 Transmitting ECGs for details Master s Step ECGs This is an optional test method that is available only in Japan For information on enabling the Master s Step Exercise option refer to Option Activation on page 126 For information on configuring the Master s Step Exercise refer to Setting Up Master s Step Test on page 159 1 Select Master s Step 2 Enter the patient s information using the appropriat
156. ossible e If the system is not configured to retrieve orders or ADT information or if it finds no matching records the system loads the patient information from the bar code and displays it in the Patient Data window MAC 5500 MAC 5500 HD 2046275 016A 2046275 016A Entering Patient Information Accept or modify the data as needed e If the system locates only one ADT record it loads that record and displays it in the Patient Data window Accept or modify the data as needed e If the system locates multiple matching ADT records it displays a list of those records Do one of the following Select the correct record to load its ADT information You can then use or modify the patient information as needed Select Cancel to load the patient information directly from the bar code You can then use or modify the patient information as needed e If the system locates one matching order it retrieves that order You can then modify the order information or begin the test e Ifthe system locates multiple matching orders it displays a list of those orders Do one of the following Select the correct order to load it You can then modify the order information or begin the test Select Cancel to load the patient information directly from the bar code You can then use or modify the patient information as needed For information on configuring your system refer to Appendix E Creating Bar Codes and Magnetic Cards
157. otocol Japan only Master s Step Records a signal averaged high resolution ECG This is a purchased option Hi Res Records a p wave signal averaged high resolution ECG This is a purchased option PHI Res Prints edits displays transmits and deletes stored ECG data File Manager Defines the operating parameters of the system System Setup Receives and prints ECG data from other devices 46 MAC 5500 MAC 5500 HD 2046275 016A System Overview US Requests displays and prints confirmed ECGs retrieved from a MUSE CV system This is a purchased option Remote Query Acquires prints and stores ECG orders received from a MUSE system with a Hospital Information System HIS interface Returns to the previous screen Selecting a Menu Function You have two methods for selecting functions from the Main Menu e Function Keys Arrow Pad Using Function Keys 1 Pressthe function key directly below the menu function to be selected 2 To display more functions on the Main Menu press the function key directly below the More menu item 2046275 016A MAC 5500 MAC 5500 HD 47 System Overview Using the Arrow Pad 1 Press the arrow keys on the Arrow Pad until the desired menu item is highlighted 2 J Press the middle button on the Arrow Pad to select the highlighted menu item Report Layout The following illustration and table describe the basic report layout
158. ou are using an ergometer the ergometer workload is automatically controlled MAC 5500 MAC 5500 HD 79 Exercise Stress Testing The exercise test advances automatically through the exercise stages unless the operator manually overrides the test NOTE When the stages in the treadmill protocol have durations other than infinite the exercise test advances from stage to stage automatically However you can press Exercise on the treadmill controller keyboard at any time to manually advance to the next exercise stage Manually adjust the treadmill s speed and grade or the ergometer s load as necessary You can adjust the speed grade or load in the following ways However once you press these keys the pre programmed protocol becomes inactive you must manually control the speed and grade during the remainder of the exercise and recovery phases Press Speed W to increase speed within 5 seconds of your last workload change e Press Speed W to decrease speed within 5 seconds of your last workload change e Press Grade to increase grade within 5 seconds of your last workload change Press Grade to decrease grade within 5 seconds of your last workload change The following menu items are available during the exercise phase of the test Press to display a list of predefined events Stage Hold Press to hold current stage Measurements Reestablish the median complex set the J point and select the three
159. page 158 for instructions on accessing the configuration window When instructed to enter a field s Offset and Length keep in mind the following information For Offset enter the field s beginning position For the first field in the bar code or magnetic card the offset will be 0 For the subsequent fields the offset is typically the sum of the previous field s offset and length However this is not always the case there may be cases where fields may have gaps between them For Length enter the total number of bytes for this field Where appropriate maximum or required lengths are noted along with any other recommendations or restrictions MAC 5500 MAC 5500 HD 191 Creating Bar Codes and Magnetic Cards Bar Code Reader and Magnetic Card Reader Configuration Fields Total number of bytes Patient ID First name 192 Enter the total number of bytes contained in the magnetic patient card or patient bar code This is typically but not necessarily the sum of the bytes listed in the following fields The patient s identification number Enter the field s Offset and Length Be aware of the following criteria when setting the length can be from 0 to 16 should equal the ID length set up on the Patient Question window should equal the patient ID length for the MUSE CV system with which the MAC system communicates The visit s identification number Enter the field s Offset and Length Be aware of the following cr
160. plete the fields described in the following tables NOTE These settings pertain only to clinical trial usage of the system CT Data Guard Clinical Trial Setup Enable Clinical Trial Enables the clinical trial features Select Yes if you will use this Data system for clinical trials Project Code Enter the code identifying the project It can be up to 32 characters long Trial 1D Enter the ID of the trial It can be up to 10 characters long Investigator ID Determines whether the investigator s ID must be entered on each test The investigator s ID can be up to 16 characters long Select Yes to require the investigator s ID Visit Number Determines whether the visit number is required on each test Visit number can be up to six characters long Select Yes to require the visit number Visit Type Determines whether the visit type is required on each test Select Yes to require the visit type If you require visit type you can edit the list of visit types You can have up to six types including the following preconfigured types Unknown Scheduled Unscheduled Repeat Early Termination Follow Up 142 MAC 5500 MAC 5500 HD 2046275 016A System Setup CT Data Guard Clinical Trial Setup cont d Dose Type Determines whether the dose type is required on each test Select Yes to require the dose type f you require dose type you can edit the list of dose types You can have up to 20 types Each type can be up t
161. plex will be saved after the first complex is saved Editing or Creating Protocols Use the following procedure to edit an existing protocol or create a new one 1 From the Main Menu select Edit Protocol 2 Select a protocol to edit or spare to create a new protocol 3 Edit the protocol parameters as desired Refer to Protocol Overview on page 83 for a description of the available parameters 4 Press Return when you are done editing the protocol parameters The Pretest phase window opens 5 Edit the stages of the phase as appropriate For more information on any of the stage fields refer to Protocol Overview on page 83 NOTE Some of the following options may not be available for each stage For example duration cannot be changed for the last stage in a phase If you select a lt lt spare gt gt protocol it has only one stage so the duration cannot be changed until additional stages are added To edit the stage d Usethe arrow pad to select the stage you want to edit 2046275 016A MAC 5500 MAC 5500 HD 85 Editing Protocols 86 b e The current stage information is displayed Edit the information When you are done press Return To change the duration Use the arrow pad to select the Duration field Enter the desired duration To enter an infinite duration delete the value in the field When you are done press Return To change the exercise intensity d Usethe arrow pa
162. r s Step Table The following table identifies the number of steps to set according to the patient s age sex and weight 2046275 016A MAC 5500 MAC 5500 HD 187 881 GH 0055 e2VIA 00SS eOVIN V910 S 29t02 NE Years TT O O O O PPD TT T CA N HEBE O E HEK UNS ERIGI EE EE Pa ee a fe as 2 E ZE Ps EZE EZE ETA HERRIN TE TE ETA Pe a so 9 ae 9 a s T s Ta Ta Ta Tar ajan 2 Ta as T ae Par as s as Ta Ta Tar j z1 ls 1 s Css ps pe pop m peu EXE ETI ps NOT N N WN N NI r nr rm O gt SS J BTN EP N SI SIT N o amp OC wile S N o S o R Le a m N N WN N N nd N N N S N S N S S SN S SJ NS O S S o os lt o a i c N Un N B N KA V910 S 29t02 GH 00SS e2VIA 00SS eOVIN 681 ke Female ale Female Female RE Years te epeta pe a pops pe pe Po ps as Par Ps Pe Pa ppp fy HER NER co LL Tea Ta Dal Ta Ta Tuj n fo MER NEN ET WE TU ao TT Ts ae ae E ES spesa Po DIDG deis s jaispy Master s Step Data ST T Changes The existence of any ST T change is assessed by classifying ST T into three assessment levels 190 Positive One of the following criteria must be met on 2 or more leads ST Depression gt 0 1mV ST Elevationz 0 2mV T wave change 2 1 0mV Borderline One of the following criteria must be met on
163. rcise options refer to Option Activation on page 126 Stress tests are controlled by test protocols Protocols consist of several phases intended to allow the patient to warm up prior to the exercise and to cool down afterward Each phase consists of stages that incrementally adjust the intensity of the exercise Depending on the exercise equipment used and the test protocol settings the MAC system may automatically adjust equipment settings during a test or notify the operator when to manually adjust the settings For more information on protocols refer to Chapter 7 Editing Protocols This chapter describes how to initiate a stress test and how to conduct each phase of the test Starting a Stress Test 2046275 016A Use the following procedure to start a stress test 1 Prepare the patient for the test and attach the leadwires Refer to Chapter 3 Preparing the Patient for instructions 2 Select the appropriate exercise test mode e Select Exercise12 to conduct a 12 lead test e Select Exercise15 to conduct a 15 lead test The corresponding ECG window opens 3 Enter the patient information Refer to Chapter 4 Entering Patient Information for instructions on entering patient information 4 Adjust the device settings as appropriate To adjust the writer settings select Writer A writer setup window opens This window allows you to turn on Arrhythmia document and cubic spline and set the paper speed
164. reader The Manual Card Reader Configuration window opens with the values filled in Press esc twice Select Save Setup gt To System Manual Configuration Use the following procedure to manually configure your magnetic card reader 2046275 016A 1 With the card reader properly mounted connect to port A on the back of the system From the Main Menu select System Setup gt Basic System gt Input Method Select gt Patient Data Input Device gt Card Reader gt Return The Manual Card Reader Configuration window opens Enter the magnetic card code configuration information For information on creating magnetic patient ID cards refer to Appendix E Creating Bar Codes and Magnetic Cards Press esc twice Select Save Setup gt To System MAC 5500 MAC 5500 HD 157 System Setup Setting Up a Bar Code Reader This section describes two methods for configuring the bar code reader e Automatic Configuration Manual Configuration NOTE When configured for a bar code reader the system will prompt you to scan the patient ID bar code when you select Patient Information If no bar code is available press esc to enter the patient information manually Do not use the bar code reader for scanning the bar code that appears on the ECG printout that bar code format is not supported by the bar code reader Automatic Configuration Use the following procedure to automatically configure your bar code reader 1
165. reports all six of the Swedish format rhythm leads are used Median Sets the method for determining the median You have two options Fixed and Scan If you select Fixed you must define the lead to use Extra Leads In addition to the report leads the 15 Lead Exercise Report also allows you to define the leads used by the three additional electrodes To configure the extra leads log on to System Setup gt Exercise Test gt 15 Lead Exercise gt Extra Leads Extra Leads Lead Set Determines the three additional leads used for 15 lead reports You can Select a predefined set of leads CML CM5 CC5 ML CMH CM5 CC5 CH NEHB D A J Frank X Y Z Select Custom 3 to define electrode positions for A1 A2 and A3 Exercise Reports The Exercise Reports settings allow you to configure the following values select the format for exercise reports e select the format for median reports The available formats for each field differ depending on whether you configure the 12 Lead Exercise report or the 15 Lead Exercise report Use the following instructions to select the correct Confirmed Reports for each report type 12 Lead Exercise Report System Setup Exercise Test 12 Lead Exercise Exercise Reports 15 Lead Exercise Report System Setup Exercise Test 15 Lead Exercise Exercise Reports 150 MAC 5500 MAC 5500 HD 2046275 016A System Setup The following table identifies the available report
166. rns To ensure defibrillation protection and protection against serious injury use only the CAM 14 or CAM HD acquisition modules with this equipment 38 MAC 5500 MAC 5500 HD 2046275 016A System Overview DN CIS CN module uses either 10 or 14 leadwires Acquisition module cable Connects the acquisition module to the MAC system ECG Button Initiates the recording of an ECG NOTE If you enable the Preview before analysis function press 5 to view the data Then either press 5 again to analyze the data or press 3 to discard the data Leadwire Labels One of the following set of labels may appear on the acquisition device CAUTION PROPER LEADWIRE CONNECTION Improper connection causes inaccuracies in the ECG Trace each individual leadwire from ts acquisition module label to the color coded connector and proper electrode to ensure that it is matched to the correct label location 2046275 016A MAC 5500 MAC 5500 HD 39 System Overview 10 Leadwire AHA 10 Leadwire IEC auf ral vif v2 v3 pooo onaga agoom 13 Leadwire AHA Pediatric 13 Leadwire IEC Pediatric l L amp amp 4 A 14 Leadwire AHA 14 Leadwire IEC BRODER OOGOES OBO 0ER0000R8 A 4 14 Leadwire AHA Aux 14 Leadwire IEC Aux hu z vo m a2 fro vs vs vs fio BIN wy RJ cific caf aifaz as ae caf osfcol 4 4 Leadwire Adapters MULTI LINK leadwires r
167. rocess of receiving from the MUSE system Consult your hospital IT department or your local GE Healthcare networking professional regarding modification of your wireless LAN to improve system performance Regardless of which method s you use to communicate with the MUSE CV system use the following procedure to receive orders 1 68 Select Ord Mgr Int The Order Manager Interface opens Select Load Orders A pop up window opens Enter the location s for which you want to retrieve orders Locations must match the locations used on the MUSE CV system Multiple locations must be separated by commas 1 13 55 Press Return The system connects to the MUSE system and retrieves a list of matching orders Select one or more orders and press Return The system loads and stores the selected orders Proceed to Selecting and Completing Orders on page 69 MAC 5500 MAC 5500 HD 2046275 016A Entering Patient Information Manually Entering Orders If you do not have a MUSE CV system or cannot connect to the MUSE CV system for some reason you can manually create the order directly on the MAC system using the following procedure NOTE The option to add orders locally must be in System Setup Refer to Order Manager Interface on page 129 1 Select Ord Mgr Int The Order Manager Interface opens 2 Select More gt Create Order The Create Order window opens 3 Enter the order information as appropriate Re
168. rs only Allows the entry of numeric values only Yes or No Allows only Yes and No answers 2046275 016A MAC 5500 MAC 5500 HD 123 System Setup Screen Colors To configure the system s screen colors log on to the System Setup screen select Basic System gt Screen Colors and complete the field described in the following table Screen Colors Screen Colors Defines the system colors Select the desired color scheme Monochrome Select this option to display white elements Option 1 Select this option to view white green yellow and red elements Option 2 Select this option to view white yellow and red elements Transmission To configure the settings for transmitting ECGs log on to the System Setup screen select Basic System gt Transmission and complete the fields described in the following table Transmission Settings Modem Speaker Determines whether the modem s tones are audible Select the appropriate value Select On to hear modem tones Select Off to silence modem tones e aie Dialing Only to hear the modem tones only when it is ialing Dialtone required Determines whether the system must be connected to a telephone line that has a dial tone Select Yes to require a dial tone Dialing method Determines the dialing method used by the telephone line Fax error correction Determines whether the facsimile machine to which you transmit ECGs uses an error correction factor Select Yes i
169. s responsible for the configuration and operation of the equipment It is expected that the user of this manual will complete thorough product training as well as read and understand all instructions in this manual before attempting to use the product Request training from GE Healthcare if needed Document Conventions This manual uses the following conventions Typographical Conventions Bold Text Indicates keys on the keyboard text to enter or hardware items such as buttons or switches on the equipment Italicized Bold Indicates software terms that identify menu items buttons or options in Text various windows CTRL ESC Indicates a keyboard operation A plus sign between the names of two keys indicates that while holding the first key you should press and release the second key For example Press CTRL ESC means to press and hold the CTRL key and then press and release the ESC key lt space gt Indicates that you must press the spacebar When instructions are given for typing a precise text string with one or more spaces the point where you must press the spacebar is indicated as lt space gt This ensures that the correct number of spaces are inserted in the correct positions within the literal text string The purpose of the lt gt brackets is to distinguish the command from the literal text within the string 30 MAC 5500 MAC 5500 HD 2046275 016A Introduction Enter Indicates that you must press the
170. s and seconds Values can range from 00 00 to 99 59 or an infinite duration If a duration is entered the stage automatically progresses to the next stage when the duration has passed If an infinite duration is entered the stage must be manually ended The last stage always has an infinite duration and continues until you manually stop the test Ergometer Sets the ergonometer workload in watts or KPM e Watts can range from 0 to 1000 in 5 watt increments e KPM can range from 0 to 6000 KPM in 25 KPM increments MAC 5500 MAC 5500 HD 2046275 016A Editing Protocols Treadmill Sets the treadmill speed in MPH or Km h and grade in percentages e MPH can range from 0 0 to 25 0 in 0 1 MPH increments e Km h can range from 0 0 to 40 0 Km h in 0 1 Km h increments Grade can range from 0 0 to 40 0 in 0 196 increments Report Sets the reports that will print and the points during the stage in which they print You can select any of the following reports No Report 12 Ld Medians 5 Second Rhythm You can also select when the first report prints and how frequently the report will be repeated during the stage Sets when you will be prompted to record the blood pressure during the stage You can select when the first prompt appears and how frequently the prompt will be repeated Median Sets how often Median complexes are saved for the final report during the stage You can select when the first complex is saved and how often the com
171. s ensures that the statements match when viewing the ECGs in the MUSE system Adult High HR Value Adult High HR enables the notification for ECGs that exceed a set heart rate Select Yes to enable Adult High HR notifications Value identifies the trigger value in beats per minute Adult heart rates that equal or exceed this value will trigger the notification Adult Low HR Value Adult Low HR enables the notification for ECGs that do not meet or exceed a set heart rate Select Yes to enable Adult Low HR notifications Value identifies the trigger value in beats per minute Adult heart rates less than or equal to this value will trigger the notification Pediatric High HR Pediatric High HR enables the notification for ECGs that exceed a Value set heart rate Select Yes to enable Pediatric High HR notifications Value identifies the trigger value in beats per minute Pediatric heart rates that meet or exceed this value will trigger the notification Pediatric Low HR Pediatric Low HR enables the notification for ECGs that do not Value meet or exceed a set heart rate Select Yes to enable Pediatric Low HR notifications Value identifies the trigger value in beats per minute Pediatric heart rates less than or equal to this value will trigger the notification High QTc Value High QTc enables the notification for ECGs where the corrected QT interval exceeds a maximum duration Select Yes to enable High QTc notifications Value id
172. sition e ECG Analysis e Patient Questions e Writer Setup e Resting ECG Reports e Report Leads Confirmed Reports e Unconfirmed Reports e Pediatric ECG Reports e Report Leads Confirmed Reports e Unconfirmed Reports e 15 Lead Reports e Extra Leads e Report Leads Confirmed Reports e Unconfirmed Reports e Vector Loops e Vector Loops e Report Leads Confirmed Reports e Unconfirmed Reports e Analog Outputs e CD Data Guard Setup e Critical Values Setup Notifications Setup Restore from SD Card e Save to SD Card Exercise Tests e Miscellaneous Setup e Patient Questions e Writer Setup e 12 Lead Exercise e Report Leads e Exercise Reports MAC 5500 MAC 5500 HD 2046275 016A System Setup 15 Lead Exercise e Extra Leads e Report Leads e Exercise Reports Final Report Screen Inputs Outputs Hi Res Master s Step Print Setup Save Setup To System To SD Card Do not save setup Restore Setup To Original Factory Settings From SD Card Do Not Restore Setup Process Overview The following procedure describes the basic flow and steps for using the System Setup function Use this process when configuring specific settings 2046275 016A 1 Select System Setup You are prompted to enter the system setup password Type the system setup password and press Return The System Setup window opens Select the function to configure The selected function s settings are displayed on the screen
173. smission cable serial line modem or client bridge wireless option 4 ANA TTL Connects to a device requiring analog data or a TTL trigger When using the exercise option connects to an analog treadmill ergometer cable or TTL trigger NOTE Ergoline bicycle ergometers must be connected to both this port and port 1 EXTVID Connects to an external video display 2046275 016A MAC 5500 MAC 5500 HD 35 System Overview qum O Exchanges ECG data with a MAC system or MUSE CV system via infrared transmission NOTE Depending on the age of your system infrared transmission may not be supported 7 Card slot Houses a system card for external data storage or to update software Ground lug Connects to non grounded peripheral devices to ensure equipotential Main AC Power Connects the system to an AC power supply via power cable Keyboard Standard Keys 36 rp NM A C Mn Hm HE EJ E Pretest Exercise Recovery Test end Speeds Grade Start tmill Recall 121d Medians Comment Enter BP Speed n Grade J STOP tmil To w py lt 4 ECG imeem rii nian m ninan es 1 2 3 4 5 6 7 8 3 Rhythm ES lt 6 a Ww E R T Y U I 0 P Stop ze 7 A sS D F 6 H J K L a a Z x V B N M A A 2 a b x VIG 085 bj EJ 6 L8 J a
174. t This section describes various methods for placing electrodes for both resting and exercise ECGs CAUTION PROPER LEADWIRE CONNECTION Improper connection will cause inaccuracies in the ECG Trace each individual leadwire from its acquisition module label to the colored connector and then to the proper electrode to ensure that it is matched to the correct label location Resting ECG Placement The following methods are applicable for resting ECGs Standard 12 Lead Placement wwe cue ome SSS z 7 i 2046275 016A MAC 5500 MAC 5500 HD 55 Preparing the Patient Standard 15 Lead Placement MCCAIN i 10 11 12 13 56 MAC 5500 MAC 5500 HD Midway between location 2 and 4 Mid clavicular line in the fifth intercostal space Anterior axillary line on the same horizontal level as 4 Mid axillary line on the same horizontal level as 4 and 5 Left deltoid Above left ankle Alternate placement upper leg as close to torso as possible Above right ankle Alternate placement upper leg as close to torso as possible Right deltoid Right anterior chest opposite of 4 Under left midscapular line Left paraspinal border 2046275 016A Preparing the Patient Frank X Y Z Placement wmuewcume oeciun z 7 light blue Right mid axillary line on the same horizontal level as 3 and 4 RA white Just below the clavicle of the right arm H light blue Back of ne
175. t of the MAC 5500 A TTL QRS trigger signal for external devices can be connected to the ANA TTL port Connecting the Acquisition Device Use the following procedure to connect the acquisition device to the MAC system 2046275 016A MAC 5500 MAC 5500 HD 41 System Overview 1 Connect one end of the acquisition module cable to the MAC system and the other end to the acquisition module 2 Connect the leadwires to the acquisition module Refer to Acquisition Equipment on page 38 for more information Verifying Correct Operation To verify the correct operation of the MAC system press the power button to turn on the system e Ifthe system starts up without displaying error messages the system is operational e Ifthe system displays error messages turn the system power off then on again If error messages persist contact GE Healthcare Service Software Overview This section provides an overview of the system software It describes the basic screen layout main menu functions and basic data entry and navigation techniques Familiarize yourself with these features before attempting to use the MAC system Test Screens The test screen differs depending on which test is selected although all test screens share some common components 42 MAC 5500 MAC 5500 HD 2046275 016A System Overview Resting ECG Screen The following illustration is the standard test screen 2 3 45 y Y yy Press ECG
176. t this option for systems running MUSE CV version 5D 04 or later This allows the ECGs to be reprinted at the original resolution of the receiving device 250Hz This option is not available with the ACI TIPI option Determines whether the system will automatically save ECGs in XML format in addition to the proprietary GE Healthcare Hilltop format If this option is selected the XML files are stored to the following path on a blank SD Card Drive XML XML Before setting this option be aware of the following e If storing ECGs in XML format DO NOT allow editing ECGs at the system Changes made to ECGs during editing WILL NOT BE SAVED to the XML file Except for the XML suffix the name of the XML file is the same as the name of the ECG file When this option is selected the SD card will fill up more quickly due to the size of the XML files e n XML files waveform data is saved as numeric points MAC 5500 MAC 5500 HD 133 System Setup ECG Analysis cont d Auto ECG storage Determines which ECGs are stored automatically e All ECGS All ECGs are stored upon completion No ECGS No ECGs are stored automatically Only ABNORMAL ECGs Only ECGs that the 12SL interpretation mark as abnormal are stored automatically Auto ECG Determines which ECGs are transmitted automatically transmission All ECGS All ECGs are transmitted upon completion No ECGS No ECGs are transmitted automatically Only ABNORMAL ECGs O
177. tent connectivity in certain areas of your facility it may be necessary to re initiate the process of receiving from the MUSE system You may also wish to consult your hospital IT department or your local GE networking professional regarding modification of your wireless LAN to improve system performance Select Remote Query Do one of the following To receive ECGs from the default MUSE CV system skip to step 3 e To receive ECGs from a different predefined MUSE CV system highlight the correct system in the list of predefined systems and proceed to step 3 e To receive ECGs from a MUSE CV system that has not been set up do the following a Select Location gt Manual Dial Press Return Enter the telephone number of the receiving device Press Return For Type select MUSE Network Press Return ans g Proceed to step 3 Select Connect The MAC system connects to the MUSE CV system Select an ECG by entering the patient s ID number NOTE If you do not know the patient s ID number enter the patient s last name You can then select the correct patient from a list of matching patients Press Return A list of matching ECGs opens Select the ECG s you want to retrieve Do one of the following e To display the selected ECG s press Display The first selected ECG is displayed You have the following options Medians displays the median complexes for the current ECG Text displays the measurements and
178. the lead quality is red or yellow a message describing the lead problem or status is displayed on the screen Hookup Advisor is enabled and configured in the ECG Acquisition menu System Setup gt ECG gt ECG Acquisition Refer to ECG Acquisition on page 131 for more information In addition to enabling disabling the Hookup Advisor feature you can set the level at which the system acknowledges poor signal quality The acknowledgement level can be set to Yellow Red default or Never Hookup Advisor continuously reviews the ECG data for acceptable lead quality e f Pre acquisition is enabled in the system setup the lead quality indicator will reflect the entire previous 10 seconds of ECG data Any displayed messages will be updated on a real time basis to reflect adjustments improvements to the lead quality Once any lead quality problems have been remedied the message Please wait will be displayed until the entire 10 second period is free from lead quality problems f Pre acquisition is not enabled the Hookup Advisor level and messages will respond to a fixed poor lead quality problem within two to three seconds When an ECG is acquired Hookup Advisor runs a complete and more comprehensive assessment of the full 10 seconds of ECG data and possibly prompts the user regarding any poor lead quality conditions e f Preview before analysis is turned off in the system setup a lead quality message and prompt may be displayed
179. the optional HI Res or PHi Res functions Signal Averaged ECGs Analysis filter Defines the analysis filter the Hi Res and PHi Res options use GE Healthcare recommends using the 40 25Hz filter Averaging target Determines which method to use to average the target Target Beat Count Determines the target heart rate Enter a value from 1 to 999 GE Healthcare recommends averaging to a minimum of 250 beats Target Noise Level Determines the target level of noise in microvolts Enter a value from 0 1 to 1 0 GE Healthcare recommends averaging a noise level of 0 3 microvolts Correlation Determines the degree of correlation threshold GE Healthcare Threshold recommends the Very High setting Final Report Determines how many copies of the final report to print Enter a value from 0 to 10 Allows you to define custom patient questions Type Allows you to set the type of response for the custom patient question Valid values are Numbers and letters Allows the entry of any alphanumeric value e Numbers only Allows the entry of numeric values only e Yes or No Allows only Yes and No answers Setting Up Exercise Tests This section describes the following stress test settings Miscellaneous Setup e Patient Questions Writer Setup Exercise Reports e Screen e Inputs and Outputs 146 MAC 5500 MAC 5500 HD 2046275 016A System Setup Miscellaneous Setup To configure the exercise tests basic settings log on t
180. to display the Additional Information line on the screen e Select No to hide the Additional Information line Distinguishes this unit from other MAC systems Enter a unique number 2046275 016A MAC 5500 MAC 5500 HD 119 System Setup Miscellaneous Setup cont d 120 Site number Location number File Manager sort Identifies the site where the unit is located This corresponds with a site number used by the MUSE CV system with which this unit communicates Valid values range from 1 254 inclusive Identifies the location where the unit is located This corresponds with the locations on the MUSE CV system with which this unit communicates Valid values range from 0 9999 inclusive Determines the method the File Manager uses to sort ECGs Delete after transmit Determines whether the system will automatically delete ECGs Text on bottom Print barcodes Automatic Shutdown Serial power always on System password after they are transmitted from File Manager to a receiving device It does not delete ECGs that are transmitted automatically after acquisition Select Yes to delete ECGs NOTE This setting does not apply when faxing ECGs When an ECG is faxed it will NOT be deleted even if this field is set to Yes NOTE This is NOT associated with the Auto order delete field on the Order Manager Interface Setup window which deletes orders after they have been successfully transmitted to a receiving device
181. to format the card Managing Files on the SD Card To use the SD card for external storage use the File Manager to copy files to the card restore files from the card and save files in XML format to the card Displaying Stored ECGs 1 2 Power on the unit Select File Manager A list of stored ECGs is displayed Choose Select The cursor moves to the screen Highlight the ECGIs to display Select Display Copying Files to the SD Card Use the following procedure to copy ECGs from internal memory to the SD card To use this option the SD Card Storage Only setting must be set to No on the Miscellaneous Setup screen NOTE 2046275 016A Copying files from internal storage to external storage deletes any files on the SD card Be sure the SD card does not contain any files you need before continuing Insert the SD card into the system s card slot Refer to Inserting and Ejecting the SD Card on page 108 Select File Manager to open the list of stored ECGs Select Copy All The following message is displayed Existing records if any in SD card will be deleted Continue Do one of the following To cancel the copy select No To continue copying the files select Yes The following message is displayed Deleting existing records if any in SD card Please wait An indicator shows the progress completion of the copying procedure MAC 5500 MAC 5500 HD 109 Using an SD Card Restoring Files from the
182. to record an ECG 000 L HH M4 1 L MACXX00 XXXX BPM HD t 6 aVR V1 V4 II aVL V2 V5 Ill aVF V3 V6 C une pee TT 1 Software Version Displays the system s software version during the first few seconds of power up User Prompts Provides additional information for the user 3 Hookup Advisor Displays the quality of the patient hookup Can be turned on or off 4 Function Icon ndicates the Main Menu function currently being used In this example the Resting ECG function is being used Battery Status Icon ndicates the status of the battery charge High Definition Pace ndicates that high definition HD pacemaker Detection Indicator detection is enabled HD provides better analysis of patients with pacemakers HD is an optional feature that is available if the following conditions are met The HDMD option has been purchased and activated The CAM HD acquisition module is connected to the system For information on activating HD refer to Option Activation on page 126 Provides access to additional settings or functions 2046275 016A MAC 5500 MAC 5500 HD 43 System Overview Exercise Test Screen The following illustration is the exercise test screen 10 Watts 1 gt Waiting for Stable Heart Rate eL LLL LA wm emm EN System Messages Provides error or other information Current Heart Rate Bar Provides a graphical representation of the patient s
183. trieves orders that have already been downloaded to the cart Cart then MUSE This option retrieves orders that have already been downloaded to the cart If it cannot find matching orders on the cart it attempts to download them from the associated MUSE CV system Automatic Reader Configuration If you are using the automatic configuration feature use the following information to create a configuration bar code or card 2046275 016A MAC 5500 MAC 5500 HD 193 Creating Bar Codes and Magnetic Cards Automatic Configuration Settings Field Character used to reserve byte space Patient ID First name Last Name Year of birth Month of birth Day of birth Gender Visit Number 194 MAC 5500 MAC 5500 HD 2046275 016A GE Medical Systems Information Technologies Inc 8200 West Tower Avenue Milwaukee WI 53223 USA Tel 1 414 355 5000 1 800 558 7044 US Only Fax 1 414355 3790 GE Medical Systems Information Technologies GmbH Munzinger Strae 5 D 79111 Freiburg Germany Tel 49 761 45 43 0 Fax 49 761 45 43 233 Asia Headquarters GE Medical Systems Information Technologies Inc Asia GE China Co Ltd No 1 Huatuo Road Zhangjiang Hi tech Park Pudong Shanghai People s Republic of China 201203 Tel 86 21 5257 4650 Fax 86 215208 2008 GE Medical Systems Information Technologies Inc a General Electric Company going to market as GE Healthcare www gehealthcare com
184. ts The device or system is labeled under the original equipment manufacturers label for example USA FCC 47CFR15 CE EU EMC 2004 108 EC and deemed sufficient by GE Healthcare to be in compliance with EN IEC 60601 1 2 when used according to the device or system s intended use GE Healthcare supplied hardware meets the applicable country requirements Class A The device or system is suitable for use in all establishments other than domestic and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes Mains power should be a typical commercial or hospital environment NOTE Compliance provides reasonable protection against radio frequency interference However there is no guarantee that interference will not occur in a particular installation You can tell whether this device or system is causing interference by turning it off If the interference stops it was probably caused by the device or system For more information regarding the installation of this product in compliance with its electromagnetic compatibility refer to the service manual 28 MAC 5500 MAC 5500 HD 2046275 016A Introduction Legal Notice Our equipment contains several fields that can be filled in before performing an ECG Some of these fields must be filled in before performing an exam some are optional and therefore left to the user to assess whether they are needed to perform the exam A
185. ure successful defibrillation WARNING ELECTRODES Polarizing electrods stainless steel or silver constructed may cause the electrodes to retain a residual charge after defibrillation A residual charge will block acquisition of the ECG signal Whenever patient defibrillation is a possibility use non polarizing electrodes silver or silver chloride construction for ECG monitoring WARNING MAGNETIC AND ELECTRICAL INTERFERENCE Magnetic and electrical fields are capable of interfering with the proper performance of the device For this reason make sure that all external devices operated in the vicinity of the device comply with the relevant EMC requirements X ray equipment or MRI devices are possible sources of interference as they may emit higher levels of electromagnetic radiation WARNING EXPLOSION HAZARD Do NOT use in the presence of flammable anesthetics vapors or liquids WARNING INTERPRETATION HAZARD Computerized interpretation is only significant when used in conjunction with clinical findings A qualified physician must overread all computer generated tracings WARNING OPERATOR Medical technical equipment such as this system must be used only by qualified and trained personnel 2046275 016A MAC 5500 MAC 5500 HD 25 Introduction 26 WARNING SHOCK HAZARD Improper use of this device presents a shock hazard Strictly observe the following guidelines Failure to do so may endanger the l
186. us Icon Indicates the status of the battery charge 12 Systolic Diastolic Blood Displays the current systolic and diastolic blood Pressure pressure readings Main Menu This section provides information about the functions available on the Main Menu and instructions on how to select functions from the Main Menu Familiarize yourself with this information before using the MAC system Main Menu Functions The following table identifies the functions available on the Main Menu The functions displayed in your Main Menu may vary due to the installation of purchased software options Records a 12 lead ECG Resting ECG e Records a 15 lead pediatric ECG The standard 12 leads and the V3R V4R and V7 leads are used Pediatric ECG Records a 15 lead vector cardiogram The standard 12 leads and gt the X Y Z leads are used Vector Loops Records an adult 15 lead ECG The standard 12 leads and three user defined leads are used 15 lead ECG 2046275 016A MAC 5500 MAC 5500 HD 45 System Overview hi Creates new or edits existing exercise test protocols Also a de protocol can be saved printed or erased E EditProtocol Conducts the 12 lead exercise test and allows you to print reports A 12 This is a purchased option Exercise 12 Conducts the 15 lead 12 standard 3 user defined leads exercise test and allows you to print reports This is a purchased option Exercise 15 Runs the Master s Step exercise pr
187. ve been purchased and enabled To assist you in recording an interference free ECG the MAC system provides a Hookup Advisor to alert you to troubles with the electrode connection NOTE The instructions in this chapter assume that the patient has been properly prepared and the electrodes have been placed correctly for the selected ECG type Refer to Chapter 3 Preparing the Patient for details Hookup Advisor The system offers the Hookup Advisor feature which is a tool for monitoring the quality of resting ECG signals and is available in the resting pediatric 15 lead vector loops and Master s Step applications It can reduce or eliminate the occurrence of poor technical quality ECGs save time and prevent the need for retakes When enabled the Hookup Advisor is displayed as a three circle indicator in the upper right corner of the screen 2046275 016A MAC 5500 MAC 5500 HD 71 Recording an ECG 72 Press ECG to record an ECG e Red indicates a lead fail condition or extreme baseline shifts The red indicator is always the left most circle of the of the indicator and flashes when lit e Yellow indicates muscle artifact power line interference baseline wander or electrode noise The yellow indicator is always the middle circle of the of the indicator Green indicates generally acceptable signal quality The green indicator is always the right most circle of the of the indicator When
188. ystem will issue a query for matching orders retrieval or patient information when scanning the bard code or magnetic card To enable data retrieval select Yes The following fields determine what information is used to conduct the query what information is retrieved and where the information is retrieved from Card Reader Value Selects the criteria used to query for additional information Options to Use are e Patient ID This option uses the patient s ID number to retrieve order or ADT information Visit This option uses the visit number to retrieve order or ADT information SWEDEN ONLY To enable support for Master Patient Index MPI you MUST select Patient ID Data to Retrieve Selects the information retrieved Options are Orders This option retrieves orders from the MUSE system or cart depending on the setting of the Retrieve Orders From field Orders then ADT if no orders This option first attempts to retrieve matching orders If no orders are found it then attempts to retrieve patient demographics ADT Patient Demographics This option retrieves patient demographics from the associated ADT system SWEDEN ONLY To enable support for Master Patient Index MPI you MUST select ADT Patient Demographics Retrieve Orders Select the source from which to retrieve order information Options are From e MUSE only This option retrieves orders from the associated MUSE CV system CART only This option re
189. ythm Ids 5 by 10s 12 Rhythm leads Autorhythm CGR Expanded Median Pharma 4 by 2 5s 2 rhythm Ids RMR Swedish Format 1 Swedish Format 2 Unconfirmed Reports The Unconfirmed Reports settings allow you to configure the following values number of copies to print for each format whether to include tic marks on the Medians Report whether to increase the median by two on the Medians Report whether to include auto gain and auto shift on the 2 by 5s Simult report the confirmation text that will print on the reports The formats are the same for each ECG type except for the Resting ECG Report which includes additional formats Use the following instructions to select the correct Unconfirmed Reports for each report type Resting ECG Report System Setup gt ECG gt Resting ECG Reports gt Unconfirmed Reports Pediatric ECG Report System Setup gt ECG gt Pediatric ECG Reports gt Unconfirmed Reports 15 Lead ECG Report System Setup gt ECG gt 15 Lead Reports gt Unconfirmed Reports Vector Loops ECG Report System Setup gt ECG gt Vector Loops ECG Reports gt Unconfirmed Reports MAC 5500 MAC 5500 HD 139 System Setup The following table identifies the available report settings for unconfirmed ECGs Unconfirmed Reports Settings Available for each report format this field determines how many copies of the report with 12SL interpretation will print You can enter any value from O to 10 If you ent