1. 1 Is heat setting in menu 5 1 2 connected Go to step 2 Some type of heat system do not have air pressure switch or vacuum switch mounted Changes heat setting 2 Is the measuring YES over 100V AC ree between P2 5 and P2 2 within 12 seconds NO when dryer is not Go to step 3 operating YES Replace the harness Replace the PCB Replace the air pressure switch 3 Are harness defective Resetting Resetting is done by opening closing the dryer loading door and pressing the start button Troubleshooting 59 E 17 Input sensor disconnected Error description This error is displayed when the inlet PT100 sensor is disconnected Error analysis 1 Defective YES PT100 sensor Measure the resistance on Go to step 2 thePT100 sensor between harness P18 4 and P18 3 on PCB Is the resistance 110 kQ NO at 20 C 68 F no Replace PT100 sensor or harness 2 Defective YES PT100 interface Replace the PCB on PCB Alternative Measure voltage between GND and T2 T2 Ti GND T2 V Resetting Resetting is done by opening closing the dryer loading door and pressing the start button 60 Troubleshooting E 18 Output sensor disconnected Error description This error is displayed when the outlet NTC sensor is disconnected Error analysis i Measure the
2. Service manual Compass Control Tumble dryers T4130 T4190 ee oF Yor_ EQ Electrolux 487 05 40 81 EN 08 36 Contents Contents Safety 0 ee re AA 5 Description sasda asa wa aaa Kok ran ehe HRs 7 Generel eranen s ar a a REIETENERE GERNE NERFRSTERE E A 7 VersionS 0 0 eee 8 Connector numbers s saasaa aoaea 9 Usage of the connections sii secutos seu 11 Program UM soy as rras Rive Re ii ea ba Hoa A 13 Menu trees ov isd cadets eh ears rk Pe or eed ae woe ae 13 Engaging service Mode oooocoooonosorrrn eee 14 SERVICE vd ee eh end wa te eee eek E 16 COMO user ood So eo o E 22 VORIGE axeteednnd che sabe beh te chee dor ae 29 a A 0 8 a a nee Bak Ose Wares weeds 41 Generell u 0a e rin wee aoe NE bd badai 41 Error codes overview 0 et ees 42 Check list error codes related to overheating 43 E09 E24 E 44 Safety rules Safety rules Programming is only to be carried out by qualified personnel High voltage on the printed circuit board IMPORTANT SERVICE NOTE Continuity and resistance measurements suggested by the procedures in this manual require that power to the dryer be disconnected and that the device whose resistance is being measured be disconnected from all circuits that might affect the accuracy of the measurement y It is very important that the oe oN is protected from static electricity Remember e Always use an earthed wrist strap e Without the antist
3. type NUMBER OF PROGRAMS Select the number of programs in the dryer 0 coin 2 AHL Autostop 3 AHL RMC 5 OPL Autostop 9 OPL RMC TIME ON TIME P Select the maximum time for time programs 10 90 minutes TIME ON AUTOMATIC P Select the maximum time for automatic programs 10 90 minutes PENDLING TIME Select the earliest time the dryer can start after it has been stopped 20 255 seconds 120 Electric heated steam heated 20 Gas heated Electric heated T4250 4350 T4300 T4190 36 Program unit RESET COUNTERS Fig Select the row RESET COUNTERS and press the knob CONFIG 2 Fig The display shows the accessible functions eee regarding resetting the counters KEIL ELS NETWORK RESET SERVICE HOURS CONFIG 3 RESET TRIP RUN HOURS ya For a more detailed description of the parameters see below To adjust parameter values set the value and press the knob RESET COUNTERS MENU 5 5 1 RESET SERVICE HOURS RESET TRIP RUN HOURS EXIT y RESET SERVICE HOURS Select this function in order to reset the service hours YES Reset the service hours NO Cancel the resetting RESET TRIP RUN HOURS Select this function in order to reset the trip run hours YES Reset the trip run hours NO Cancel the resetting Program unit ELS NETWORK Fig Select the row ELS NETWORK and press the knob Fig The display shows the accessible parameters regarding ELS network the default values are liste
4. operate the dryer YES Does the E10 return Replace the PCB Re enter user desired parameter settings time per push coin for example These are erased when factory defaults are restored 52 Troubleshooting E 11 Drying error with RMC Error description Error code E11 occurs if the RMC system does not register that the clothes are dry within 90 minutes factory setting The dryer stops automatically when the clothes have the chosen residual moisture Error analysis 1 Are P10 1 and Check the wiring YES P10 2 connected connections RMC belt on Go to step 2 YES drum and lifter insulation The measuring is Are they in working no Replace the defective parts done with an empty order drum Has the heating been insufficient due to a blown fuse Go to step 3 2 Is the air in dryer cold Check for short circuit and replace NO Go to step 3 the fuses and restart YES Remove some of the clothes and restart 3 Is the dryer overfilled with clothes Check factory setting for NO max drying time Max drying time Menu 5 4 3 Resetting Resetting is done by opening closing the dryer loading door and pressing the start button Troubleshooting 53 E 12 Drying error with Auto Stop system Error description Error code E12 occurs if the Auto Stop system doe
5. The dryer stops operating Error analysis 1 Has fuse FH300 blown 2 Disconnect P1 and P2 from the PCB Check for continuity over the heat thermostate F5 F6 Is the circuit closed 3 Missing air flow 4 Check the inlet outlet temperature YES Replace the fuse and restart the dryer Go to step 2 Replace PCB Go to step 3 See Check list error codes related to overheating YES Correct the error from the check list Are there any errors according to the list Go to step 4 Is the inlet and outlet temperature parameter set correctly YES Replace PCB Inlet Factory setting for Inlet temperature Menu 5 2 1 Outlet Factory setting for outlet temperature Menu 2 1 1 2 2 1 2 3 1 etc up to 2 11 1 Enter the ra programming mode and adjust the parameter 50 Troubleshooting E 09 Option Not in use Troubleshooting 51 E 10 Programming errors Settings Error description This error occurs when the parameter set up is inconsistent Note When resetting the circuit board the user adjusted programs disappear and need reprogramming The dryer stops operating Error analysis 10 1 Enter the service program Set Menu 10 1 to 1 to restore all factory settings All user desired programming will be overwritten Exit programming mode and attempt to
6. a descriptive text Whenever an error occurs the dryer stops operating ERROR E 18 THE OUTPUT SENSOR HAS DISCONNECTED Error analysis A diagnostic procedure is provided for each error code If an error has not been corrected after the procedure please contact the manufacturer for additional assistance 42 Troubleshooting Error codes overview Error code E 01 E 02 E 03 E 04 E 05 E 06 E 07 E 08 E 09 E 10 E 11 E 12 E 13 E 14 E 15 E 16 E 17 E 18 E 19 E 20 E 21 E 22 E 23 E 24 Description Option Not in use Option Not in use Inlet air Sensor has short circuited The thermistor element measuring the air inlet temperature to the drum or the wiring to the sensor has shorted Outlet air Sensor has short circuited The thermistor element measuring the air outlet temperature from the drum or the wiring to the sensor has shorted Fan motor Motor 1 The thermal protection switch in the motor or its harness is open Drum motor Motor 2 The thermal protection switch in the motor or its harness is open Option Not in use Inlet and Outlet air protection thermostats One of the proctection thermostats has opened due to overheating Option Not in use Setting Programming error incorrect or missing parameter s Drying error Maximum allowable RMC time exceeded non coin operated models only Drying error Maximum allowable Autostop time exceeded non coin
7. another temperature is selected 4 No heat After a program has been selected the dryer starts automatically on no heat unless another temperture is selected 5 Last temperature After a program has been selected the dryer starts automatically on the temperature last selected 26 Program unit SHOW COUNTER Fig Select the row SHOW COUNTER and press the Knol CONFIG 1 Fig The display shows the accessible functions MENU 4 2 regarding which counters to be shown on the HERRIN i g LANGUAGE display the default values are listed to the right SPECIAL CONTROL SHOW COIN COUNTER ON I O ADDRESS EXIT SHOW HOUR COUNTER ON For a more detailed description of the functions see below To connect disconnect the function select ON or OFF and press the knob SHOW COUNTER MENU 4 2 1 SHOW COIN COUNTER SHOW HOUR COUNTER EXIT 4 SHOW COIN COUNTER Select whether the contents of the machine s coin counter should be shown in the display window while a drying program is in progress or outside the drying program without going into service mode The counter is shown on the display after pressing the control knob twice in quick succession ON The contents of the coin counter can be shown Displayed after pressing the control knob twice in succession when drying or before the drying program starts OFF No display of the contents in the coin counter SHOW HOUR COUNTER Select whether the contents of the machine s hou
8. co ANTICREASE ON For a more detailed description of the functions see further below ROTATION MENU 5 3 1 On T4900 41200 the factory setting is 12 sec CLOCKAISE On machines w reversing 1 motor the factory ae REV setting is 15 sec ANTICREASE ext To adjust parameter values set the value and press the knob CLOCKWISE Select for how long the rotation must be clockwise only if reversing is ON Duration 01 99 minutes PAUSE BETWEEN REV Select how long the pauses between reversings must be only if reversing is ON Duration 01 99 seconds REVERSING Select the duration of the reversing only if reversing is ON Duration 01 99 minutes on machines w reversing 1 motor the duration is 01 99 seconds ANTICREASE Select whether the anticrease function must be on or off 0 OFF 1 ON Program unit 35 MAXIMUM Fig Select the row MAXIMUM and press the knob The display shows the accessible parameters CONFIG 1 Fig regarding the maximum settings the default u values are listed to the right 4 MAXIMUM RESET COUNTERS NUMBER OF PROGRAMS 0 9 ELS NETWORK TIME ON TIME P 90 i TIME ON AUTOMATIC P 90 e PENDLING TIME 20 255 For a more detailed description of the parameters see below MENU 5 4 1 To adjust parameter values set the value and NUMBER OF PROGRAMS press the knob TIME ON TIME P TIME ON AUTOMATIC P PENDLING TIME The default value is depending on the machine a
9. motor is connected to the PCB This error indicates that the thermal protection switch or the harness between the board and the switch has opened A defective PCB can also cause this error The dryer stops operating Error analysis 1 Is the motor clogged by lint or dust YES Clean the motor no Go to step 2 2 Does the Replace motor run Is the motor seized YES motor or clear slowly or is it blockage locked NO Go to step 3 3 Unplug motor control Is there continuity over YES connector P1 the termal protection and P2 from the switch for the fan F7 PCB NO Connect P2 and P4 Does the error reoccur when the motor is restarted NO YES Put the dryer back into operation Is the motor cold The error occurs immediately Replace the PCB The error occurs after a while s operation Defective motor protection replace the fan motor Check harness and connector Replace motor harness connector Wait until the motor is cold and restart it Troubleshooting 47 E 06 Drum motor Overheating protection motor 2 Error description The thermal protection switch inside the drum motor is connected to the PCB This error indicates that the thermal protection switch or the harness between the board and the switch has opened A defective PCB can also cause this e
10. operated models only Drying error Requested drying time is longer than maximum allowed dryer connected to a payment system Gas error A flame was not detected on gas heated dryers Vacuum switch The vacuum switch pressostat does not shut within 12 seconds after the dryer is started Vacuum switch The vacuum switch pressostat was already closed when an attempt to start the dryer was made Inlet sensor disconnected The inlet thermistor or wiring to the thermistor is open Outlet sensor disconnected The outlet thermistor or wiring to the thermistor is open Option Not in use CMIS out of operation The dryer is put out of order in the PC programme CMIS com board poll error The PC does not poll the dryer within the time out LM10 com board poll error The PC does not poll the dryer within the time out Option Not in use Condensate container The condensate container is full and the pump is not pumping Troubleshooting 43 Check list error codes related to overheating General note regarding error codes related to overheating Before troubleshooting the electronic systems of the machine examine the dryer to determine if the airflow is normal Insufficient airflow due to over filling the machine lint obstructed screens air passages and ducts or improper exhaust venting are all possible causes of various errors Items concerning the necessary air flow 1 oN O A Check that the fresh air intake to the room and
11. resistance on YE Be ae the NTC sensor between 2 Go to step 2 P18 5 and P18 6 on PCB Is the resistance between 4kQ and 6kQ at 20 C NO _ Replace NTC sensor 68 F or harness Alternative Measure voltage between GND and T1 T2 T1 GND T1 V Resetting Resetting is done by opening closing the dryer loading door and pressing the start button E 19 Option Not in use Troubleshooting 61 62 Troubleshooting E 20 CMIS out of operation Error description This error is displayed if the dryer is put out of order in the CMIS program Error analysis See separate manual Troubleshooting 63 E 21 CMIS polling error warning Error description This error is displayed if the dryer is connected in a CMIS system and the PC does not communicate with the dryer no polling within 10 sec time out factory setting The error is displayed the 10 first times the dryer is started and after this it will not reappear Note This is a warning and the dryer will operate even though the error has been activated Error analysis 1 Has CMIS been started on Go to step 2 the PC Start the CMIS program on the PC which is connected to the ELS Network 2 Has the ELS Go to step 3 Network been connected Mount the ELS correctly Network cables correctly Make an error diagnosis in the CMIS system 3 Has the ELS Network bee
12. the exhaust ducts pipes from the room are not clogged by lint dust or blocked in any other way Check that the dryer receives the necessary quantity of fresh air See installation manual Check that the fresh air intake preasure drop does not exceed 10 Pa applies only to air intake duct kit if installed See installation manual Check that the pressure drop in the air outlet ducts does not exceed the value printed on the data sheet in the Service Manual for the specific dryer Measurement is done with cold air 20 C 68 F Check that the air inlet screen on the rear of the dryer is not clogged by lint or dust Check that the lint screen is clean and in good condition Check the door gasket and internal sealing against the drum are defective missing dirty Check that the blower compartment and fan wheel have not become blocked with lint or other debris Check that the fan wheel is in good condition and that it is tightly secured to the motor shaft 10 Check for severely overloaded dryer Remove some items as appropriate Items concerning gas connection 1 2 Check that the gas type corresponds with the dryer s data plate Check gas inlet and nozzle pressures 44 Troubleshooting E 03 Inlet air Sensor has short circuited Error description This error code indicates that the inlet air thermistor connected to the PCB or the harness from the PCB to the thermistor has short circuit
13. this equals 300 seconds if 220 is specified in the display this equas 2200 seconds TIMEOUT END BUZ SEC Specify with the knob the time during which the buzzer should sound at the end of the program unless the machine is turned off manually The time is given in seconds 0 255 SHOW TIME RMC and AHL only Select whether the calculated remaining drying time is to be shown on the display while the program is in progress ON The calculated time remaining of the program is shown on the display while a drying program is an progress OFF No time is displayed in the display window Program unit 25 SHOW TEMP Select if the current drying temperature in the drum is to be shown in the display during the ongoing drying program ON The drying temperature is to be shown OFF No drying temperature to be shown in the display DEFAULT TEMP Select the default drying temperature in the drum 0 No temperature No default temperature is selected and there fore a temperature must be selected after every program selection 1 High temperature After a program has been selected the dryer starts automatically on high temperature unless another temperature is selected 2 Medium temperature After a program has been selected the dryer starts automatically on medium temperature unless another temperature is selected 3 Low temperature After a program has been selected the dryer starts automatically on low temperature unless
14. 1 P2 P3 P4 P5 P6 P7 P8 P9 P10 P11 P12 P13 P14 P15 P16 P17 P18 P19 P20 P21 P22 P23 Motor control Vacuum and fan input Power on Power out Heat control Els Network Els Network 18V AC out 18v AC in RMC RS 232 internal use incl 24V DC RS 232 programme Data bus incl 24V DC Data bus incl 24V DC Gas control Rotary Compass Control Display Compass Control Temperature sensor and filter input External gas reset and service switch Discount and external error option Free drying CP CMS CMSNCB ESS PCR CMD 11 Program unit 13 Menu tree The machine software is constructed with menus that are structured according to the menu tree below The menus become available when the machine is in service mode see section Engaging service mode SERVICE ACTIVATE OUTPUTS SHOW INPUTS ARTICLE NUMBER SHOW COM PORTS STATUS I O BOARD DISPLAY TEST See programming manual See programming manual MAIN MENU j CONFIG 1 TIMEOUT DISPLAY SEC SPECIAL CONTROL TIMEOUT FND BUZZ SEC I O ADDRESS QUICK START BUTTONS ADJUST DISPLAY RESET SHOW COIN COUNTER SHOW HOUR COUNTER DEFAULT LANGUAGE LANGUAGE TIMEOUT SEC SHOW F CONFIG 2 See programming manual RESET SERVICE HOURS RESET TRIP RUN HOURS See programming manual See programming manual See programming manual 14 Program unit Engaging service mode Service mode is engaged using
15. OM OPL Compass mode PROGRAMS Select program type both no and type is displayed as shown in the list below 0 COIN 1 OPLRMC 2 AHLRMC 3 OPLAUTO 4 AHLAUTO Program unit 33 TEMPERATURE Fig Select the row TEMPERATURE and press the knob CONFIG 2 Fig The display shows the accessible functions E parameters regarding the temperature the default TEMPERATURE i i ROTATION values are listed to the right MAXIMUM INLET TEMPERATURE N A RESET COUNTERS ELS NETWORK e HYSTERESIS 2 C AUTOSTOP N A For a more detailed description of the functions parameters see below There are no default values listed as the values TEMPERATURE depend on the configuration of the machine MENU ae INLET TEMPERATURE HYSTERESIS To adjust parameter values set the value and AUTOSTOP press the knob pe INLET TEMPERATURE Select the inlet temperature 80 180 C However all machines without inlet sensor 0 C eg T4130 HYSTERESIS Select the hysteresis on the outlet temperature 1 10 C AUTOSTOP Select the outlet temperature the dryer must reach before it stops and the clothes are dry 30 70 C only on dryers with this function 34 Program unit ROTATION Fig Select the row ROTATION and press the knob The display shows the accessible parameters e Fig regarding the rotation the default values are listed ee to the right 4 E MAXIMUM e CLOCKWISE 5 RESET COUNTERS PAUSE BETWEEN REV ge Le REVERSING
16. atic wrapping the board is unprotected e Keep all subjects away from the board which can cause static electricity e Subjects like plastic foam plastic nylon or cellophane wrapping are all big dischargers of static electricity e Static electricity can not always be felt heard or seen e Board components can be damaged by static electricity under 100V e Static electricity can not be felt heard or seen till the voltage reaches 2500V Generel Description From factory the dryer has been set to specific values for Time temperature cooling reversing etc The above parameters are changeable by reprogramming the Selecta Control PCB Selecta Control PCB The PCB Module is located under the top cover on the front of the machine see the service manual for the specific dryer In order to reprogramme the dryer it is necessary to switch the print board into programming mode Glossary Auto Stop The tumble dryer stops automatically when the clothes are dry AHL GN LPG OPL PCB RMC CP CMD CMS CMSNCB ESS PCR Apartment House Laundry Communal laundries Housing block laundries Natural gas Bottle gas On Premises Laundry Institutional laundries Printed Circuit Board Residual Moisture Control The tumble dryer has residual moisture control Central Payment Coin Meter Double Coin Meter Single Coin Meter No Coin Box Electrolux Single System Prepared for Card Reader 8 Description Version
17. ction select ON or REVERSING ON OFF OFF and press the knob TYPE OF HEATING To adjust parameter values set the value and ne ae press the knob Y PROGRAMS There are no default values listed as the values depend on the configuration of the machine Program unit REVERSING ON OFF Select whether the function reversing should be turned on or off ON Reversing ON OFF Reversing OFF TYPE OF HEATING Select type of heating both machine and heating type is displayed as shown in the list below 0 1 T4300S Electric 2 T4300S Gas 3 T4300S Gas US JP Steam T4250 4350 Electric T4250 4350 Gas T4250 4350 Gas US JP T4900 41200 Electric 10 T4900 41200 Gas 11 T4900 41200 Gas US JP 12 T4290 4530 4650 Electric 13 T4290 4530 4650 Gas 14 T4290 4530 4650 Gas US JP 15 T4190 Electric PD9 16 T4190 Gas PD9 Gas 17 T4190 Gas USA PD9 Gas US JP 18 T4130 Exhaust 19 T4130 Condensate 20 32 Program unit PAYMENT SETTING Select payment type both no and type is displayed as shown in the list below CS a 1 1COINNC 2 1COIN NO 3 2COINNC 4 2COINNO 5 CP TIME 6 SINGLE SYSTEM 7 CP COIN 8 MASTER 9 LM10 CONTROL PANEL Select control panel type both no and type is displayed as shown in the list below 0 Selecta mode 1 COIN Selecta mode 2 AHL Selecta mode 3 OPL Selecta mode 4 COIN JP Selecta mode 5 TIME Selecta mode 6 COM COIN Compass mode 7 COMAHL Compass mode 8 C
18. ctrode 3 Is the gas supply nozzle pressure okay YES Replace the ignition control or gas valve Ventilate the gas system contact gas supplier 4 Is the current between the connector and the ionisation at least 0 9uA DC Is there continuity in the harness Adjust the sensor NO Replace the sensor Troubleshooting 57 E 15 Air pressure switch or vacuum switch Error description The air pressure switch or the vacuum switch does not shut within 12 seconds after the fan has started Error analysis B BB See check list 1 Is the YES Correct airflow problem underpressure in the as appropriate drum compartment Go to step 2 YES Go to step 3 2 Does the fan motor rotate in the correct direction below 90Pa NO Check the motor s connection and phase order 3 Is the measuring Replace PCB over 100V AC between P2 5 and P2 2 within 12 seconds when dryer NO Replace the air pressure is not operating switch Resetting Resetting is done by opening closing the dryer loading door and pressing the start button 58 Troubleshooting E 16 Air pressure switch or vacuum switch does not open Error description The error occurs if the vacuum switch air pressure switch is already closed when an attempt to start the dryer is made Error analysis IE
19. current protocol STATUS 1 0 BOARD DISPLAY TEST EXIT 4 j SHOW COM PORTS STATUS I O BOARD Fig Select the row STATUS I O BOARD and press the knob The display now shows the status for the I O BOARD SERVICE MENU 1 5 4 STATUS I O BOARD DISPLAY TEST EXIT Program unit DISPLAY TEST T Gs Select the row DISPLAY TEST and press the knob The display shows a checked grid for checking that all segments in the display are intact By turning the knob two different grids are shown Press the knob to return to the previous menu 21 SERVICE MENU 1 6 4 DISPLAY TEST EXIT 6204 22 Program unit CONFIG 1 In the menu CONFIG 1 all the functions as well as parameters which the service personnel can change without a password are shown Engage the service mode on the machine Fig Select the row CONFIG 1 in the main menu and press the knob In the display following submenus are now shown Fig USER INTERFACE SHOW COUNTER e LANGUAGE e SPECIAL CONTROL e O ADDRESS Select a submenu and press the knob MAIN MENU MENU 4 1 ARE COIN VALUE QUICK START BUTTONS apsust DISPLAY CONFIG 1 MENU 4 1 USER INTERFACE SHOW COUNTER LANGUAGE SPECIAL CONTROL 4 I O ADDRESS Program unit USER INTERFACE Fig Select the row USER INTERFACE and press the 21 knob Fig The display shows the accessible functions parameters regarding the user interface
20. d to the right MACHINE ADDRESS 0 BAUD RATE 0 TIME OUT 0 DRYER TYPE N A For a more detailed description of the parameters see below To adjust parameter values set the value and press the knob There is no default value as the dryer type is set from factory MACHINE ADDRESS 4 ELS NETWORK 37 CONFIG 2 MENU 5 6 CONFIG 3 EXIT ELS NETWORK MENU 5 6 1 MACHINE ADDRESS BAUD RATE TIME OUT DRYER TYPE 4 EXIT Select the number address of the machine in the network 0 not in network 1 27 available numbers BAUD RATE Select the communication speed 0 38400 BAUD 1 2400 BAUD 2 9600 BAUD 3 38400 BAUD TIME OUT Select when the dryer must report a time out error 0 99 seconds CMIS 10 sec error code E21 LM10 90 sec error code E22 to be continued 38 Program unit continued DRYER TYPE Select which type of machine the dryer is this will be communicated to the computer 1 74130 2 13190 3 T3250 4 T3350 5 T3300 TD30 30 6 T4290 TD30 7 T4530 TD50 8 T4650 TD75 10 T4250 11 T4350 12 T4900 TD100 13 T41200 TD135 14 T4300S TD30x30S 15 T4190 CONFIG 3 Manufacturer use only Program unit 39 Troubleshooting 41 General The dryer is equipped with an automatic diagnostic system An error in the program or in the machine is indicated on the display by an error message comprising an error code and
21. e container Error analysis The pump is working but the drain might be partly blocked 1 Turn the machine on and off Is water coming out of the hose Go to step 2 2 Is the pump The drain is blocked running after the machine has been turned on NO and off Go to step 3 3 Check in YES Select the correct the service type of heating menu that the correct TYPE OF HEATING has NO been selected Go to step 4 MENU 5 1 2 4 Does the YES Check wire and small 24 Selecta Control V circuit board relay 487027951 t the machine has Grange been turned on and off A oF Yor_ X Electrolux www electrolux com laundrysystems Share more of our thinking at www electrolux com
22. e is started The progam unit will return to the language set here if the machine is not used during the period specified in the LANGUAGE TIMEOUT menu LANGUAGE TIMEOUT SEC Specify with the knob the time after which an unused machine should return to the set default language and return to the program selection The time is given in steps of 10 seconds 0 255 seconds Examples if 030 is specified in the display this equals 300 seconds e if 220 is specified in the display this equas 2200 seconds SHOW F Select whether all the temperature values are to be displayed in C or F ON 1 All temperature values displayed in F OFF 0 All temperature values displayed in C 28 Program unit I O ADDRESS Fig Select the row l O ADDRESS and press the knob Fig The display shows the accessible functions eal regarding the 1 0 ADDRESS settings the default values are listed to the right 4 ETE ACTIVATE I O BOARD OFF O BOARD 1 N A y O BOARD 2 N A O BOARD 3 N A For a more detailed description of the functions see below I O ADDRESS To connect disconnect the function select ON or MENU 4 5 1 OFF and press the knob OE I O BOARD 1 I O BOARD 2 I O BOARD 3 exit There is no default value ACTIVATE I O BOARD Activate the I O board it is very important to keep in mind that P13 and P14 can not be used as ordinary I O eg condensate pump T4130 I O BOARD 1 3 There is no value pr
23. ed A defective detection circuit in the PCB can also cause this error The dryer stops operating Error analysis Measure the resistance 1 Defective of the PT100 sensor and YES PT100 sensor or harness between P18 3 E Go to step 2 harness and P18 4 on the PCB Is the resistance 110 Q at 20 C 68 F NO Replace PT100 sensor or harness 2 Defective NTC interface Replace the PCB on PCB Alternative Measure voltage between GND and T2 T2 V Troubleshooting 45 E 04 Outlet air Sensor has short circuited Error description This error code indicates that the outlet air thermistor connected to the PCB or the harness from the board to the thermistor has short circuited A defective PCB can also cause this error The dryer stops operating Error analysis 1 Defective NTC sensor or harness Measure the resistance of the NTC sensor and harness between P18 5 and P18 6 on main circuit board Is the resistance between 4 to 6 KQ at 20 C 68 F 2 Defective NTC interface on PCB NO Replace NTC sensor or harness Replace the PCB Alternative Measure the voltage between GND and T1 iaa dl ES T2 Ti GND T1 V 46 Troubleshooting E 05 Fan motor Overheating protection motor 1 Only in machines with 2 motors Error description The thermal protection switch inside the fan
24. ess botton with above number on I O board Program unit 29 CONFIG 2 In the menu CONFIG 2 all the functions as well as parameters which the service personnel can po ri only change using a password are shown Engage the service mode on the machine t ann s y QUICK START BUTTONS Fig Select the row CONFIG 2 in the main menu and ADJUST DISPLAY press the knob y RESET TO FACTORY Fig In the display a password must be entered in order to gain access to CONFIG 2 The password is 0001 PASSWORD To enter the password Turn the knob clockwise to set the number between 0 and 9 0000 e Turn the knob anti clockwise to move to the 4 next column Turn the knob clockwise to set the value etc Fig In the display following submenus are now 32 shown CONFIG PCB TEMPERATURE ROTATION ee MAXIMUM MENU 5 1 RESET COUNTERS TEMPERATURE ELS NETWORK ROTATION MAXIMUM RESET COUNTERS Select a submenu and press the knob 30 Program unit CONFIG PCB Fig Select the row CONFIG PCB and press the knob The display shows the accessible functions CONFIG 2 x a x MENU 5 1 Fig parameters regarding the configuration of the pcb module TEMPERATURE REVERSING ON OFF ROTATION TYPE OF HEATING Dar EN e PAYMENT SETTING e CONTROL PANEL e PROGRAMS For a more detailed description of the functions parameters see the following page CONFIG PCB MENU 5 1 1 To connect disconnect the fun
25. ess the knob Fig The display now shows the sensor signals 11 inputs which can be controlled DOOR CLOSED e VACUUM e EXTERNAL INPUT e PRICE REDUCTION e FILTER CLOSED e OVERHEAT e GAS INPUT FAN OVERHEAT DRUM OVERHEAT FREE DRY e COIN 1 e COIN 2 e QUICK START 1 e QUICK START 2 e ANALOG Select function and press the knob More inputs can be activated simultaneously SERVICE MENU 1 2 5 SHOW INPUTS ARTICLE NUMBER SHOW COM PORTS STATUS I O BOARD DISPLAY TEST ACTIVATE OUTPUTS MENU 1 2 1 DOOR CLOSED VACUUM EXTERNAL INPUT PRICE REDUCTION y FILTER CLOSED Program unit 19 ARTICLE NUMBER Fig Select the row ARTICLE NUMBER and press the knob SERVICE f f f MENU 1 3 The display now shows a list of which article 4 i i numbers and versions can be displayed see SON COM POROS below STATUS I O BOARD DISPLAY TEST EXIT SOFTWARE VERSION Fig Select the row SOFTWARE VERSION and press the knob The display now shows the software version ARTICLE NUMBER MENU 1 3 1 PARAMETER VERSION Fig Select the row PARAMETER VERSION and PARAMETER VERSION press the knob EXIT The display now shows the parameter version ARTICLE NUMBER MENU 1 3 2 PARAMETER SOFTWARE EXIT y 20 Program unit SHOW COM PORTS Fig Select the row SHOW COM PORTS and press the knob SERVICE MENU 1 4 The display now shows the status for communication according to the
26. it an E must already be engaged in service mode and y e Es then the gas reset button B must be pressed To leave boot mode press the gas reset button again or download new software 16 Program unit Service The service program is used to facilitate trouble shooting the machine Using this programe it is MAIN MENU possible to MENU e control the machine functions individually SERVICE PARAMETER PROGR STATISTICS CONFIG 1 conric 2 control the sensor signals to the CPU board e check the communication in the machine control system e check the display Fig Engage the service mode and select the row SERVICE in the main menu and press the knob H SERVICE The display now shows the different submenus in MENO den the service program Fig ACTIVATE OUTPUTS SHOW INPUTS ARTICLE NUMBER SHOW INPUTS Pesta COM PORTS ARTICLE NUMBER A A SHOW COM PORTS e STATUS I O BOARD DISPLAY TEST Select menu and press the knob Program unit 17 ACTIVATE OUTPUTS Fig Select the row ACTIVATE OUTPUTS and press the knob SERVICE f MENU 1 1 The display now shows the functions outputs which can be activated SON TNEUTZ HEAT ARTICLE NUMBER SHOW COM PORTS DIRECTION srarus I O BOARD EXT SIGNAL FAN DRUM Fig Select function and press the knob Ace uns MENU 1 1 1 DIRECTION EXT SIGNAL FAN Drum 18 Program unit SHOW INPUTS Fig Select the row SHOW INPUTS and pr
27. n set up correctly reg Baud rate addresses and time out An Adjust menus 5 6 1 address cannot 5 6 2 5 6 3 be used twice 64 Troubleshooting E 22 LM10 polling error Error description This error is displayed if the dryer is connected in a LM10 system and the PC does not communicate with the dryer no polling within 90 sec time out factory setting The error can only be removed if communiction is re established Note It is not possible to use the dryer however it can be done by means of the free of charge key Error analysis 1 Has LM10 Go to step 2 been started Start the LM10 which is connected to the ELS Network 2 Has the ELS Pe tostep d Network been connected Mount the ELS correctly Network cables correctly 3 Has the ELS Make an error Network been diagnosis in the LM10 system set up correctly reg Baud rate addresses and time out An NO Mount the ELS address cannot Network cables be used twice correctly E 23 Option Not in use Troubleshooting 65 66 Troubleshooting E 24 Condensate container is full Error description Every time a program is started the pump will run for approx 15 seconds in order to empty the container Afterwards the pump will run every 5 minutes This error is displayed if the pump has tried to empty the container whitout the level sensor having detected a level drop in th
28. r counter should be shown in the display window while a drying program is in progress or outside the drying program without going into service mode The counter is shown on the display after pressing the control knob twice in quick succession ON The contents of the hour counter can be shown Displayed after pressing the control knob twice in succession when drying or before the drying program starts OFF No display of the contents in the hour counter Program unit 27 LANGUAGE Fig Select the row LANGUAGE and press the knob The display shows the accessible functions CONFIG 1 Fig parameters regarding language selection the MENU S53 default values are listed to the right 4 LANGUAGE SPECIAL CONTROL DEFAULT LANGUAGE N A I O ADDRESS LANGUAGE TIMEOUT SEC 12x10 en lt SHOW F OFF For a more detailed description of the functions parameters see below To connect disconnect the function select ON or OFF and press the knob an To adjust parameter values set the value and press the knob The arrow shows the number to be DEFAULT LANGUAGE diusted LANGUAGE TIMEOUT SEC ad SHOW F e Turn the knob clockwise to set the number ia between 0 and 9 Turn the knob anti clockwise to move to the next column Turn the knob clockwise to set the value etc There is no default value as the language is selected when the machine is installed DEFAULT LANGUAGE Select the language to be shown when the machin
29. rror The dryer stops operating Error analysis 1 Is the motor clogged by lint or dust YES Clean the motor NO Go to step 2 Is the motor seized 2 Does the motor run slowly or is the rotor locked Replace motor or clear blockage The error occurs no Go to step 3 immediately Connect P1 and YES Replace the PCB Is there continuity P2 Does the PA through the thermo fuse error reoccur when the motor for the drum F8 is restarted The error occurs YES after a while s operation Defective motor protection circuit replace the fan motor or harness 3 Unplug motor control connector P1 and P2 from the PCB Put the dryer back into operation Check motor YES harness and con nector Replace motor harness connector Is the motor cold NO Wait until the motor is cold and restart it 48 Troubleshooting E 07 Option Not in use Troubleshooting 49 E 08 Inlet air outlet air Overheating thermostat Error description A normally closed manual reset high limit thermostat measuring the inlet air temperature The thermostat is connected in series with the overheating thermostat for outlet air on the PCB This error indicates that one of the two thermostats or the connecting harness has opened A defective PCB can also cause this error
30. s Software version The software version is only readable in menu 1 3 1 see section Program Unit If the software has been upgraded a label has been affixed Hardware version The hardware data is printed on a label see fig 1 The label is affixed on the print board which is facing downward towards the drum The label is only visible when the print board is demounted Parameter version The parameter version is only readable in menu 1 3 2 see section Program Unit raw Hardware version 4870279270P2005450050 Part number 487 02 79 27 Revision 00 Year 2005 Serial number 0050 Description 9 Connector numbers In the error analyses in the section Troubleshooting later in this manual connections P1 P23 are mentioned The P numbers are printed on the print board The usage of the connections appears from the wiring diagrams supplied with the dryer The positionings of P1 P23 are shown on the following page High voltage on the printed circuit board Do not touch the printed circuit board The shaded areas indicate high voltage See view1 gt E FERRY lares ER me See view 2 next page p E en 85 a next page iW SS EUR i gt DANGER HIGH VOLTAGE SN SD NE SS AS E Mi ats E Utii Er Ld ia Anima Warning The shaded areas indicate high voltage LN Description 10 Description Usage of the connections It is possible to connect following features to the PCB P
31. s not register that the clothes are dry within 90 minutes factory setting Error analysis El BB Has the heating been insufficient due to a blown fuse Go to step 2 Go to step 2 Check for short circuit and replace the fuses and restart 1 Is the air in dryer cold 2 Is the dryer Remove some of the overfilled with clothes and restart clothes Check factory setting for Auto Stop Max drying time Menu 5 4 3 Autostop temp Menu 5 2 3 Resetting Resetting is done by opening closing the dryer loading door and pressing the start button 54 Troubleshooting E 13 Drying error dryer connected to a payment system Error description Error code E13 occurs with Payment systems where the customer or system has requested a longer drying time than the allowed 90 minutes factory setting on the dryer Error code is not displayed but is registered in the error log Error analysis 1 Which type of eg LM10 Incorrect payment system system setup Max 90 min CP ESS YES Check that there are no Is the errors on the connected connection payment system or between P22 harness and correct these on PCB and the payment system disconnected No ncorrect payment system set up max 90 min or defective PCB Troubleshooting 55 E 14 Gas error Error description When the ignition control fails to detec
32. t a flame a signal is sent to the PCB and error code E14 is displayed The metal probe of the flame sensor generates an electrical current when exposed to the burner s flame This signal is detected by the ignition control module which in turn cuts off the gas valve immediately if the sensor does not indicate flame within 5 sec The integrity of the sensor s electrical connection is therfore critical to proper operation of this system Displaying error code E14 USA and Japan The error code is not displayed until the 3rd unsuccessful ignition attempt Europe The error code is displayed at the 1st unsuccessful ignition attempt Error analysis See next page Resetting Resetting is done by pushing the gas reset button on the circuit board Japan only By opening and closing the door coin operated dryers only 56 Troubleshooting E 14 Gas error Gas resetting See on the preprevious page Error analysis Bl BB Is the flame sensor placed in the flame is the sensor s electrical connection okay NO the electrode connections 1 Is there a short lived flame at the ignition attempt YES Replace the ignition control YES 2 Is an ignition Go to step 3 spark present YES Go to step 3 Is the ignition electrode placed correctly is the connection okay NO Adjust clean replace the ele
33. the default values are listed to the right e BUTTON CLICK OFF e STANDBY VALUE 00 e STANDBY VALUE BLINKS OFF e FINAL BLINKS ON TIMEOUT DISPLAY SEC 12x10 e TIMEOUT END BUZ SEC 10 e SHOW TIME OFF SHOW TEMP OFF e DEFAULT TEMP 0 For a more detailed description of the functions parameters see the following pages Fig To connect disconnect the functions select ON or OFF and press the knob To adjust parameter values set the value and press the knob The arrow shows the number to be adjusted Turn the knob clockwise to set the number between 0 and 9 e Turn the knob anti clockwise to move to the next column Turn the knob clockwise to set the value etc 23 CONFIG 1 MENU 4 1 USER INTERFACE SHOW COUNTER LANGUAGE SPECIAL CONTROL I O ADDRESS USER INTERFACE MENU 4 1 1 BUTTON CLICK STANDBY VALUE STANDBY VALUE BLINKS FINAL BLINKS Y uzour DISPLAY SEC STANDBY VALUE 000 4 24 Program unit BUTTON CLICK Select whether the machine should give a sound for each new position when the knob is turned and pressed in ON Sound OFF No sound STANDBY VALUE Not yet in use STANDBY VALUE BLINKS Not yet in use FINAL BLINKS Not yet in use TIMEOUT DISPLAY SEC Specify with the knob the time after which the machine should reset a program selection that has not started The time is given in steps of 10 seconds 0 255 x 10 seconds Examples if 030 is specified in the display
34. the service switch on the CPU board under the top cover on the front of the machine Fig Press the service button The machine software will now switch to its LE service mode The display lists the submenus 7 available in this mode HEN SAR une s SELECTA II REV 1 30 DANGER HIGH VOLT Thi d ib f ti d NER NN LER QUIE P4 eSINNNNNNNN is service manual describes functions an m7 MAI aaa Bl i EEE aa El programming instructions for the following submenus e SERVICE e CONFIG 1 CONFIG 2 Fig For other submenus please refer to the 2 programming manual MENU T Fig To save changes to the machine s memory they E ee 3 must be confirmed in a menu that is displayed STATISTICS automatically whenever a change has been y ern a made NEW VALUE IS ARE YOU SURE YES Program unit 15 Special modes for PCB SELECTA MODE 4 BOOT MODE There is a possibility that the CPU board is programmed to use the Selecta display Selecta mode The Compass display is lit and the Selecta display shows 0_ _ In order to engage Compass service mode keep pressing the service button when the power is turned on There is a possibility that the CPU board is in Boot mode In Boot mode new software for the CPU board can be downloaded A special PC program is required ES Boot mode All gt e of Pe A Rae temperature is lit and the display is turned off PaaS nel ii iTi In order to engage the CPU board in boot mode
Download Pdf Manuals
Related Search
Related Contents
Sunbeam SCH160 User's Manual HP AlphaStation DS15 - Centre for Advanced Internet Architectures (CAIA) Chapter 11_Trace Xerox Phaser 6600 User's Manual 44733 EFL Viking model 12 Book.indb Cooper Lighting Combolight GR420 User's Manual SERVICE MANUAL, BELLY PAN REPLACEMENT 1 - トヨタ自動車 Copyright © All rights reserved.