1. When replacing the battery align positives and push down to fully seat Battery Fully Seated Correct Battery lt Battery replacement is Orientation 3 volt lithium coin cell 0 D type 2032 X TRITON 1 2 Programming Manual Page 5 OEM General Instructions The control valve offers multiple procedures that allow the valve to be modified to suit the needs of the installation These procedures are OEM Cycle Sequence OEM Softener System Setup e OEM Filter System Setup Installer Display Settings User Display Settings Diagnostics e Valve History Once the OEM Cycle Sequence has been set the other procedures can be accessed in any order Details on each ofthe procedures are provided on the following pages To lock out access to diagnostic and valve history displays and modifications to settings except hardness day override time of regeneration and time of day by anyone but the manufacturer press W NEXT and SET CLOCK in sequence after settings are made To unlock so other displays can be viewed and changes can be made press NEXT A and SET CLOCK in sequence When in operation normal user displays such as time of day volume remaining before regeneration present flow rate or days remaining before regeneration are shown When stepping through a procedure if no buttons are pressed within five minutes the display returns to a normal user dis
2. E NEXT REGEN STEP 4I SETTIME REGEN eli E NEXT REGEN STEP 51 SETTIME REGEN LILI E NEXT REGEN RETURN TO NORMAL MODE TRITON 1 2 Programming Manual Installer Display Settings STEP 11 Press NEXT and A simultaneously for 3 seconds STEP 21 Hardness Set the amount of hardness in grains of hardness as calcium carbonate per gallon using or A The default is 20 with value ranges from 1 to 150 in 1 grain increments Note The grains per gallon can be increased if soluble iron needs to be reduced This display will show nA if FILTER is selected in Step 2F or if AUTO is not selected in Set Gallons Capacity in OEM Softener System Setup Press NEXT to go to step 3l Press REGEN to exit Installer Display Settings STEP 3l Day Override When volume capacity is set to off sets the number of days between regenerations When volume capacity is set to AUTO or to a number sets the maximum number of days between regenerations If value set to oFF regeneration initiation is based solely on volume used If value is set as a number allowable range from 1 to 28 a regeneration initiation will be called for on that day even if sufficient volume of water were not used to call for a regeneration Set Day Override using V or A number of days between regeneration 1 to 28 or OFF See Setting Options Table for more detail on setup Press NEXT to go to step 41
3. REGEN SET CLOCK SALT SET CLOCK REGEN In Alternator Systems when a unit is waiting to initiate the first cycle step of regeneration REGEN PndG is displayed STbY is displayed in Alternator Systems when a valve is in Standby state REGEN PndG FILL RINSE is displayed whenever a zero capacity tank has transferred to an off line state and is currently waiting to initiate the second portion of a regeneration cycle Viewed only when Delayed Rinse and Fill is set to ON LBS REMAINING REGEN REGEN Prd 5 bY Prd FILL RINSE Page 18 TRITON 1 2 Programming Manual Regeneration Mode Typically a system is set to regenerate at a time of low water usage An example of a time with TIME ay REMAINING low water usage is when a household is asleep If there is a demand for water when the system is REGEN c Hec MIN regenerating untreated water will be used BACKWASH When the system begins to regenerate the display will change to include information about the step of the regeneration process and the time remaining for that step to be completed The system runs through the steps automatically and will reset itself to provide treated water when the regeneration has been completed Manual Regeneration CAPACITY REMAINING Sometimes there isa need to regenerate the system so
4. RETURN TO NORMAL MODE Step 7F Set Volume Capacity using or A If value is set to oFF regeneration will be based solely on the day override set see Installer Display Settings Step 31 or a number regeneration initiation will be based off the value specified See Setting Options Table for more detail Press NEXT to go to Step 8F Press REGEN to return to previous step Step 8F Set Regeneration Time Options using or A If value is set to means regeneration will occur at the preset time on O means regeneration will occur immediately when the volume capacity reaches 0 zero or NORMAL on 0 means regeneration will occur at one of the following the preset time when the volume capacity falls below the reserve or the specified number of days between regenerations is reached whichever comes first or immediately after 10 minutes of no water usage when the volume capacity reaches 0 zero NORMAL is the default if Step 4CS is set to ALTA or ALTB and NORMAL 0 is not available See Setting Options Table for more detail Press NEXT to exit OEM Filter System Setup Press REGEN to return to previous step Page 16 SET CLOCK NEXT REGEN w SET HARDNESS cu SET CLOCK NEXT REGEN SET REGEN DAY M
5. NEXT REGEN SET clock NEXT REGEN Twinalternating systems can be programmed with a day override setting combined with the normal volume based regeneration programming A twin alternating system in this configuration will then regenerate based on the volume used or the day override if there is a period of low water usage Twin alternating systems can be programmed as a time clock only based regenerating system In this configuration the days remaining are counted only on the unit that is in service The unit in Stand by Mode only notes days in diagnostics which results in time clock only twin regeneration initiation Twin alternating systems can be programmed for a delayed regeneration time The system will allow an immediate transfer of the to switch tanks and place a fully regenerated unit in service once a unit becomes exhausted The exhausted unit will then be placed into Stand by Mode and allowed to have a delayed regeneration at the pre set time TRITON 1 2 Programming Manual Page 9 Configuring the Control Valve to operate with Clack System Controller Select SYS to link the Control Valve to the Clack System Controller For communication between the Control Valve and the System Controller a three wire communication cable is required Press NEXT to go to Step 565 Press REGEN to return to previous step Step 5CS Allows select
6. 10 tank transfers The first position in the display ranges from 0 to 9 with the lowest number being the most recent transfer The second position in the display will be either A or b If A then the tank with the valve on it was in service if b the tank with the in out head on it was in service The next three digits represent the number of hours ago that the transfer occurred The display alternates with the volume that was treated before the tank transferred Press NEXT at any time to go to Step 7D Press REGEN to return to previous step STEP 7D Flow rate maximum last seven days The maximum flow rate in gallons per minute that occurred in the last seven days will be displayed This display will equal zero if a water meter is not installed Press NEXT to go to Step 8D Press REGEN to return to previous step TRITON 1 2 Programming Manual Page 21 STEP 8D TIME thes TODAY NEXT REGEN Press and hold and SET CLOCK buttons for 3 seconds while in Step 8D to TE reset the drive history in both the retracted and extended piston L REGEN H lel rod position To view the and extended rod position press and hold SET CLOCK and A while NUN in Step 8D Press NEXT to advance display to the old MAV drive L history SOFTENING 1 9 5 TODAY L SET CLOCK NEXT REGE
7. Press REGEN to return to previous step STEP 41 Next Regeneration Time hour Set the hour of day for regeneration using or A AM PM toggles after 12 The default time is 2 00 AM This display will show REGEN on 0 GAL if on 0 is selected in Set Regeneration Time Option OEM Softener System Setup or OEM Filter System Setup Press NEXT to go to step 51 Press REGEN to return to previous step STEP 51 Next Regeneration Time minutes Set the minutes of day for regeneration using V or A This display will not be shown if on 0 is selected in Set Regeneration Time Option in OEM Softener System Setup or OEM Filter System Setup Press NEXT to exit Installer Display Settings Press REGEN to return to previous step To initiate a manual regeneration immediately press and hold REGEN for three seconds The system will begin to regenerate immediately The control valve may be stepped through the various regeneration cycles by pressing REGEN TRITON 1 2 Programming Manual User Display Settings General Operation When the system is operating one of five displays may be shown Pressing NEXT will alternate between the displays One of the displays is always the current time of day The second display is one of the following days remaining or volume remaining Days remaining is the number of days left before the system goes through a regeneration cycle Capacity remaining is the gallons that will be
8. have both 2 0 and 2 0L selection choices the valve must be set to 2 0 if using a 2 meter or 1 5 if using a 1 5 meter during programming If a WS2L valve is being used with newer version software that has both 2 0 and 2 0L selection choices the valve must be set for 2 0L during programming TRITON 1 2 Programming Manual Page 7 STEP 4 5 Step 465 Allows selection of one of the following using or V sm e the Control Valve to have no hard water bypass HL H the Control Valve to act as an alternator or REGEN the Control Valve to have a separate source during the regeneration cycle or the Control Valve to operate with the Clack System Controller SET clock NEXT REGEN Select OFF when none of these features are used ATV This display will not appear if 1 0 was selected in Step 5 Only use Clack No Hard Water Bypass Valves or Clack Motorized Alternating Valves MAV with these selections Clack No Hard Water Bypass Valves 1 or 1 25 V3070FF or V3070FM are not designed to be used with the alternator or separate source functions Configuring the Control Valve for No Hard Water Bypass Operation Select nHbP for control operation For no hard water bypass operation the three wire connector is not used Selection requires that a connection to MAV or a Clack No Hard Water Bypass Valve is made to the two pin connector labeled ALTERNATOR DRIVE located on the printed circuit boar
9. if the dP function dPdEL is set the Delayed Rinse and Fill feature is not available HoLd If the dP switch is closed a regeneration will be prevented from occurring while there is switch closure In a twin alternating system the regeneration ofa unit can be prevented upon switch closure If theunitdepletes the capacity downto zero it will not be allowed to switch tanks to regenerate until the switch is open Note For WS1 WS2L control valves programmed for twin alternating the Delayed Rinse and Fill feature can be set in conjunction with the if desired Press NEXT to go to Step 6CS Press REGEN to return to previous step Page 10 TRITON 1 2 Programming Manual Step 6CS Press W or A until BACKWASH appears Press NEXT to go to Step 7CS Press REGEN em to return to previous step BACKWASH 0 NEXT REGEN CLOCK Step 7CS Press V or A until dn BRINE appears For a WS1 control valve prior to selecting a regenerant flow cycle verify the correct valve body main piston regenerant piston and stackare being c d used and the injector or injector plug s are in the correct location Refer to WS1 amp WS1 25 Drawings If and Service Manual Valve Body Compliance Table Press NEXT to go to Step 8CS Press REGEN to Next REGEN return to previous step E SET SET CLOCK Step 8CS Press W or A until RINSE appears Press NEXT to go to Step 9
10. to 200 Fill for WS2 Valves or WS1 5 set to MIN 0 1 to 99 0 Service 1 to 480 Note Fill is in pounds of salt except for WS2 Since no time is associated with the END cycle the END cycle will not appear in the OEM Softener System Setup sequence SET CLOCK REGEN STEP 2S SET SOFTENING SET CLOCK NEXT REGEN H MIN BACKWASH NEXT REGEN i c BO BRINE SET CLOCK NEXT REGEN 1 SET 3 MIN RINSE SET CLOCK NEXT REGEN SET d LBS bu FILL SET CLOCK NEXT REGEN 1 Step 15 Press NEXT simultaneously for 3 seconds and release If screen in Step 2S does not appear in 5 seconds the lock on the valve is activated To unlock press W NEXT A and SET CLOCK in sequence then press NEXT and simultaneously for 3 seconds and release Step 2S Choose SOFTENING using or A Press NEXT to go to Step 3S Press REGEN to exit OEM Softener System Setup Step 3S Select the time for the first cycle which in this example is BACKWASH using V or A Press NEXT to go to Step 4S Press REGEN to return to previous step Step 4S Select the time for the second cycle which in this example is dn BRINE using or A Press NEXT to go to Step 5S Press REGEN to return
11. CS Press REGEN to return SET to previous step SET clock NEXT i RINSE REGEN Step 9CS Press V or A until FILL appears Press NEXT to go to Step 10CS Press REGEN to return SET to previous step NEXT REGEN L FILL SET CLOCK Step 10CS Press W or A until END appears Press NEXT to go to Step 11CS Press REGEN to return SET to previous step 5 End NEXT REGEN SET CLOCK Step 11CS Fill Units If set as a softener if Step 2CS is set to 1 5 and FILL SET SET LBS is part of the Regeneration Cycle Sequence FILL UNITS of MIN or LBS N can be selected Press NEXT to exit OEM Cycle Sequence Press REGEN to a FILL return to previous step clock REGEN SET clock NEXT REGEN RETURN TO NORMAL MODE TRITON 1 2 Programming Manual Page 11 OEM Softener System Setup In OEM Softener System Setup the OEM chooses the time for the cycles selected in OEM Cycle Sequence and specifies other operating parameters for the system The upper and lower limits of the allowable values for the cycles are as follows Cycle Options Lower Upper Limit 1 to 120 Rinse fast 1 to 120 dn Brine combination of brining and slow rinse 1 to 180 up Brine combination of brining and slow rinse 1 to 180 Fill for 1 1 25 1 5 and 2 0L 0 01
12. E 11 Fill for 1 1 25 1 5 and 2 0L 0 01 to 200 Fill for WS2 Valves or WS1 5 set to MIN 0 1 to 99 0 Step 25 65 delete the and button PAGE 12 Step 7S 10S delete the and button PAGE 14 Step 2F 6F delete the and button PAGE 15 Step 7F 8F delete the and button PAGE 16 Step 21 51 delete the and button PAGE 17 If 1 0 is selected in Step 2CS an A in front of the flow rate indicates that the tank with the control valve on it is in service If displayed the tank with the in out head is in service PAGE 18 Reneration Mode updated display on right side Manual Regeneration delete the and button Step 2U and 3U delete buttons PAGE 19 Step 105 delete the and button Step 3US delete the and button Power Loss updated display on right side PAGE 20 Step 4D Display does not appear if 1 0T is selected in Step 2CS Added Step 6D Step 2D 7D delete the and button PAGE 21 Added Step 8D 9D PAGE 22 Inserted Step 2VH Step 3VH 6VH delete the and button 3 Values in steps 2VH through 6VH cannot be reset Page 24 TRITON 1 2 Programming Manual Revision History 1 23 2013 9 dPdEL revisions PAGE 13 Reserve Capacity estimate is based on history of water usage Reserve Capacity estimate is not available with alternator systems or Twin Tank Valve PAGE 20 STEP 5D drawing revision PAGE 21 STEP 8D MAV D
13. F Select the time for the first cycle which in this example is BACKWASH using V or A SET Press NEXT to go to Step 4F Press REGEN to return to previous step MIN BACKWASH SET CLOCK NEXT REGEN 1 Step 4F Select the time for the second cycle which in this example is BRINE using or A SET Press NEXT to go to Step 5F Press REGEN to return to previous step c 5 E 7 NOTE The display will flash between cycle number and time and brine direction dn Brine BRINE NEXT REGEN i SET CLOCK Step 5F Select the time for the third cycle which in this example is RINSE using W or A Press SET NEXT to go to Step 6F Press REGEN to return to previous step RINSE SET NEXT rece Step 6F Select the volume in gallons for the fourth cycle which in this example is FILL using W a or A When both 2 0 and 2 0L are options in Step 2CS and 2 0 is selected FILL is in minutes WS2 5 6 valves shipped from the factory with a refill flow control of 2 2 gpm 8 3 lpm Press NEXT to go to Step 7F Press REGEN to return to previous step SET CLOCK NEXT REGEN TRITON 1 2 Programming Manual Page 15 REGEN 100 SET CLOCK NEXT REGEN SETTIME REGEN NORMAL on L SET CLOCK NEXT REGEN
14. N i RETURN TO NORMAL MODE STEP 8D MAV Drive History in the direction of extended piston TE rod position Display will not be shown if 1 0T is not selected in H IL Step 2CS and OFF is selected in Step 4CS If the display does appear up a four digit number will appear after the which stands for latest and A which stands for average Drive time is measured in 1 100 of a second i e 17 10 second move is displayed as 1710 Press NEXT at any time to go to Step 9D Press REGEN to return to previous step TIME old MAV drive history data for retracted gt SOFTENING A 129 STEP 9D Drive History in the direction of retracted piston 0 0 rod position Display will not be shown if 1 0 is not selected in Step E H 1 IC 2CS and OFF is selected in Step 4CS If the display does appear fow up to a four digit number will appear after the 1 which stands for latest and A which stands for average Drive time is measured in 1 100 of a second i e a 17 15 second move is displayed as 1715 Press hold A and for 3 seconds while in Step 9D to reset the MAV drive history in both the extended and retracted piston rod position To view the old MAV drive history data see Step 8D Press the NEXT button at any time exit Diagnostics Press REGEN to return to previous step When desired all program
15. TRITON PROGRAMMING MANUAL 1 2 CONTROL VALVE REIONATOR SOFTMAX SORBMAX AIR OXIMAX AIR NITROMAX FERROMAX WATER TECH Table of Contents CC Front Cover and Drive Assembly 4 OEM General Instr ctions rrt retirement rosae koe 5 OEM Cycle Sequence OEM Softener System Setup Setting Options Table OEM Filter System Setup n Installer Display Settings erneuten trennt User Display Settingg Diagnostics UE Page 4 TRITON 1 2 Programming Manual CC Front Cover and Drive Assembly Drawing No Order No Description Quantity 1 V3175CC 01 WS1CC FRONT COVER ASSEMBLY 1 2 V3107 01 WS1 MOTOR 1 3 V3106 01 WS1 DRIVE BRACKET amp SPRING CLIP 1 4 V3108CC 05BOARD WS1 THRU2L 2 CC PCB ALT REPLACE XMEGA 1 5 V3110 WS1 DRIVE REDUCING GEAR 12X36 3 6 V3109 WS1 DRIVE GEAR COVER 1 V3186 WS1 AC ADAPTER 120V 12V V3186EU WS1 AC ADAPTER 220 240V 12V EU Not Shown 1 V3186UK WS1 AC ADAPTER 220 240V 12V UK V3186 01 WS1 AC ADAPTER CORD ONLY Not Shown V3178 WS1 DRIVE BACKPLATE 1 AC Adapter U S International Supply Voltage 120 V AC 230V AC Supply Frequency 60 Hz 50 Hz Output Voltage 12V AC 12V AC Output Current 500 mA 500 mA
16. d If using a MAV the A port of the MAV must be plugged and the valve outlet connected to the B port When set to nHbP the MAV will be driven closed before the first regeneration cycle that is not FILL or SOFTENING or FILTERING and be driven open after the last regeneration cycle that is not FILL NOTE If the control valve enters into an error state during regeneration mode the no hard water bypass valve will remain in its current state until the error is corrected and reset Configuring the Control Valve for Separate Source Operation Select SEPS for control operation For separate source operation the three wire connectoris not used Selection requires that a connection to a Clack Motorized Alternator Valve MAV is made to the two pin connector labeled ALTERNATOR DRIVE located on the printed circuit board The C port of the MAV must be connected to the valve inlet and the A port connected to the separate source used during regeneration The B port must be connected to the feed water supply When set to SEPS the MAV will be driven closed before the first regeneration cycle and be driven open after the last regeneration cycle NOTE If the control valve enters into an error state during regeneration mode the MAV will remain in its current state until the error is corrected and reset Selecting the Control Valve to act as an alternator Software Rev Level 223 0 and higher Use 3 wire Interconnect Cable for all communication betwee
17. ds and release NEXT REGEN STEP 2CS Step 2CS Use A or V to select 1 0 for WS1 valve 1 25 for WS1 25 valve 1 5 for WS1 5 valve 2 0 for WS2 2 0L for a WS2L valve or 1 0 for a twin valve SET chock NEXT REGEN SET CLOCK SE win 5 Note When using the WS2 valve if 2 0L is set instead of 2 0 when the valve is in regeneration m and the piston drives to the DRAW cycle the piston will stall and generate a 1002 error code en Clear the error code by pressing NEXT REGEN simultaneously until the valve resets then l AT V re program valve to proper valve type setting Press NEXT to go to Step 3CS Press REGEN to exit OEM cycle sequence Step 3CS When 2 0L or 2 0 are selected an additional screen will appear It is used to select which size flow meter is to be used with the valve 1 5 or 2 0 Press NEXT to go to Step 4CS Press REGEN F L n el to return to previous step SET c Em NEXT REGEN SET When using the WS2 control valve the circuit board software must have meter selection choices of 2 0 and 2 0L The WS2 valve must be set for the 2 0 meter selection during programming If the software version does not have both the 2 0 and 2 0L selections consult your equipment supplier for a replacement circuit board When using the WS2L valve with older version software that does not
18. ess NEXT to go to Step 10S Press REGEN to return to previous step Step 10S Set Low Salt Warning using or A If value is set to no low salt level warning will appear for the user or i rn a specific value FILL SALT will flash on the display when the calculated remaining pounds of salt falls below that level Allowable SET T uec Tac values range form 10 to 400 pounds in 10 pound increments When both 2 0 and 2 0L are options in Step 265 and 2 0 is selected this step is skipped and not active Press NEXT to exit OEM Softener System Setup Press REGEN to return to previous step TRITON 1 2 Programming Manual Page 13 Setting Options Table Filters should only use shaded options Volume Regeneration Day Capacity Time Option Override Reserve capacity automatically estimated AUTO NORMAL oFF Regeneration occurs when volume capacity falls below the reserve capacity at the next Regen Set Time Reserve capacity automatically estimated AUTO NORMAL Any Regeneration occurs at the next Regen Set Time when volume capacity number fallsbelowthereservecapacity orthe specified number of days between regenerations is reached A Reserve capacity not automatically estimated y NORMAL oFF Regeneration occurs at the next Regen Set Time when volume number capacity reaches 0 FF HF F ne Reserve capacity not automatically estimated oFF NORMAL nm Regeneration occurs at the ne
19. ified NORMAL on 0 ane number number numberofdaysbetweenregenerationsisreachedorregenerationoccurs after 10 minutes of no water usage when volume capacity reaches 0 Reserve Capacity estimate is based on history of water usage Reserve Capacity estimate is not available with alternator systems or Twin Tank Valve Page 14 TRITON 1 2 Programming Manual OEM Filter System Setup In OEM Filter System Setup the OEM chooses the time for the cycles selected in OEM Cycle Sequence and specifies other operating parameters for the system The upper and lower limits of the allowable values for the cycles are as follows Cycle Options Lower Upper Limit 1 to 120 Rinse fast 1 to 120 dn Brine combination of regenerant and slow rinse NOTE Fill is in gallons except for WS2 Since no time is associated with the END cycle the END cycle will not appear in the OEM Filter System Setup sequence Step Press NEXT and simultaneously for seconds and release If screen in Step 2F does not appear in 5 seconds the lock on the valve is activated To unlock press W NEXT A and SET CLOCK in sequence then press NEXT and W simultaneously for 3 seconds and release NEXT REGEN STEP 2F Step 2F Choose FILTERING using or A Press NEXT to go to Step Press REGEN to exit SET CLOCK SET OEM Filter System Setup FILTERING NEXT REGEN SET CLOCK Step 3
20. ion of one of the following using or V SE SEES e an outside signal to initiate a regeneration S dPo outside signal to prevent or delay a regeneration Selection only matters if a connection is made to the two pin connector labeled DP SWITCH located SET on the printed circuit board Following is an explanation of the options AIV NOTE In a twin alternating system each control must have a separate dP signal or dP switch One signal or one dP switch cannot be used for both controls If the dP switch is closed for an accumulative time of 2 minutes a regeneration will be signaled to the unit In a twin alternating system the MAV will transition first to switch units so that the signaled unit can start regeneration After the MAV has fully transitioned the regeneration begins immediately Note For WS1 WS2L control valves programmed for twin alternating if the dP function dPonO is set the Delayed Rinse and Fill feature is not available dPdEL If the dP switch is closed for an accumulative time of 2 minutes a regeneration will occur at the scheduled delayed regeneration time In a twin alternating system once the dP switch is triggered the PC board will display REGEN TODAY and switch tanks immediately At the Delayed Regeneration Time the triggered unit will then regenerate Note For WS1 WS2L control valves programmed for twin alternating
21. l flash on and off which indicates the time of day should be reset If a power outage lasts less then 24 hours and the time of day flashes on and off the time of day should be reset and the battery replaced STEP 1U Press SET CLOCK NEXT REGEN SET CLOCK STEP 2U Current Time hour Set the hour of the day using or A AM PM toggles after 12 SETTE Press NEXT to go to step 3U 595 NEXT SET CLOCK STEP 3U Current Time minutes Set the minutes of the day using W or A Press NEXT to exit SIT Set Clock Press REGEN to return to previous step 535 1 Bis RETURN TO NORMAL MODE SET CLOCK TRITON 1 2 Programming Manual Salt Remaining or Adding Salt not available for WS2 valves Page 19 If the Low Salt Warning was activated in the last step of OEM Softener System Setup the following screens will be viewed in the User Display Note The salt used per regeneration setting can be set in increments of 0 1 pounds but the LBS REMAINING screen will round up or down to the closest whole number SALT SET CLOCK NEXT REGEN LBS REMAINING Once the salt remaining has gone below the set point the display will automatically flash Salt Fill SALT FILL NEXT REGEN SET CLOCK When adding sal
22. ming and all information in Diagnostics may be reset to defaults when the valve is installed in a new location To reset to defaults press NEXT and W simultaneously to go to the Softening Filtering screen Press A and V simultaneously to reset diagnostic values and all programming to defaults Screen will return to User Display Page 22 SET CLOCK SET CLOCK NEXT REGEN 3 REGEN c 3L SET CLOCK NEXT REGEN DAY qi SET CLOCK NEXT REGEN STEP 4VH REGEN c 45 NEXT REGEN STEP 5VH 71 GAL La cock NEXT REGEN STEP 6VH m 5 Lt LOK NEXT REGEN L RETURN TO NORMAL MODE TRITON 1 2 Programming Manual Valve History STEP 1VH Press A and simultaneously for three seconds and release Then press A and simultaneously and release If screen in step 2VH does not appear in 5 seconds the lock on the valve is activated To unlock press NEXT A and SET CLOCK in sequence then press and simultaneously for 3 seconds and release Then press A and W simultaneously and release STEP 2VH Software version This display shows the software version of the valve Press the NEXT button to go to Step3VH Press REGEN to exit the valve history STEP 3VH Day
23. n units Software Rev Level 222 5 and lower Use 2 wire Interconnect Cables for twin alternators with independent flow meters Priortostartingtheprogrammingsteps connecttheinterconnectcabletoeach control valve board sthree pin connectorlabeled INTERCONNECT Also connect the meter cord to either control valve to the three pin connector labeled METER a Softener Valve Programming Steps Set to ALTA Connect ALTA valve to the MAV s A Step 4CS port and connect the MAV s two pin wire connector to the two pin connector labeled Set to ALTb Connect valve to the MAV s B port No connections between the ALTB valve and the MAV are made Softener System Step 85 Set to AUTO Set to AUTO Setup dir de Step 9S Set regeneration time option to On Set regeneration time option On t Step 3l Set Day Over ride to oFF Set Day Over ride to oFF OEM Cycle Sequence DRIVE on the ALTA valve Page 8 TRITON 1 2 Programming Manual If set up for a filter in Step 7F set Volume Capacity in Gallons in Step 8F select Regeneration Time Option on 0 and in Step 3l select Day Override oFF NOTE If the control valve is in an error state during regeneration mode the MAV will close the B port and keep open the A port until the error is corrected and reset For Clack Corporation alternator systems using WS1 WS1 25 WS1 5 and WS2L valves there will be an option to delay the last two cycles of regeneration o
24. nly Rinse and Fill This feature splits the regeneration into two portions The first portion of the regeneration will start immediately and all programmed cycles before the Rinse and Fill cycles will be performed After all programmed cycles before Rinse and Fill are completed the control valve will drive to the service position displaying Delayed Rinse Fill Pending When the volume of the on line unitis depleted to 1096 of its programmed capacity the control valve will be triggered to finish the second portion of the regeneration Once Rinse and Fill are completed the valve will re enter Standby mode until requested to come on line for Service For Clack Corporation alternator systems using the WS2 valve when NEXT is pressed after selecting ALTA or ALTB a display will allow the user to set the amount of pre service rinse time for the stand by tank just prior to returning to service Retracted Extended Valve A in Service Position Note Clack Twin Alternator Operations dELAY FILL Valve B in Service Position MAV MAV piston rod Retracted piston rod Extended RINSE WS1 WS1 25 WS1 5 WS2L Valves PAKETEA 9 clock NEXT REGEN Em NEXT REGEN
25. o to Step 4D Press REGEN to return to previous step STEP 4D Volume reserve capacity used for last 7 days If the valve is set up as a softener a meter is installed and Set Volume Capacity is set to Auto this display shows 0 day for today and flashes the reserve capacity Pressing A will show day 1 which would be yesterday and flashes the reserve capacity used Pressing A again will show day 2 the day before yesterday and the reserve capacity Keep pressing A to show the capacity for days 3 4 5 and 6 V can be pressed to move backwards in the day series Display does not appear if 1 0 is selected in Step 2CS Press NEXT at any time to go to Step 5D Press REGEN to return to previous step JJ STEP 5D Volume 63 day usage history This display shows day 1 for yesterday and flashes the volume of water treated yesterday Pressing A will show day 2 which would be the day before yesterday and flashes the volume of water treated on that day Continue to press A to show the maximum volume of water treated for the last 63 days If a regeneration occurred on the day the word REGEN will also be displayed This display will show dashes if a water meter is not installed Press NEXT at any time to go to Step 6D Press REGEN to return to previous step 15 STEP 6D Twin Tank Valve Transfer History only displays when 1 0T was selected in Step 2CS Use A or V to scroll through the last
26. onerthan whenthe REGEN TODAY will be GAL system calls for it usually referred to as manual regeneration There may displayed if a regeneration TODAY be a period of heavy water usage because of guests ora heavy laundry expected Tonight cL next day To initiate a manual regeneration at the preset delayed regeneration time when the regeneration time option is set to NORMAL or NORMAL on 0 press and release REGEN The words REGEN TODAY will flash on the display to indicate that the system will regenerate at the preset delayed regeneration time If you pressed REGEN in error pressing the button again will cancel the request Note If the regeneration time option is set to on 0 there is no set delayed regeneration time so REGEN TODAY will not activate if REGEN is pressed To initiate a manual regeneration immediately press and hold REGEN for three seconds The system will begin to regenerate immediately The request cannot be cancelled Note For softeners if brine tank does not contain salt fill with salt and wait at least two hours before regenerating Set Time of Day The user can also set the time of day Time of day should only need to be set after power outages lasting more then 24 hours if the battery has been depleted and a power outage occurs or when daylight saving time begins or ends If a power outage occurs lasting more then 24 hours the time of day wil
27. play Any changes made prior to the five minute time out are incorporated To quickly exit OEM Softener Setup OEM Filter Setup Installer Display Settings Diagnostics or Valve History press SET CLOCK Any changes made prior to the exit are incorporated When desired all information in Diagnostics and all programming may be reset to defaults when the valve is installed in a new location To reset to defaults press NEXT and W simultaneously to go to the Softening Filtering screen Press A and V simultaneously to reset diagnostic values and all programming to defaults Screen will return to User Display Sometimes it is desirable to have the valve initiate and complete two regenerations within 24 hours and then return to the preset regeneration procedure It is possible to do a double regeneration if the control valve is set to NORMAL or NORMAL on 0 in OEM Softener System Setup or OEM Filter System Setup To do a double regeneration 1 Press REGEN once REGEN TODAY will flash on the display 2 Press and hold REGEN for three seconds until the valve regeneration initiates Oncethe valve has completed the immediate regeneration the valve will regenerate one more time atthe preset regeneration time Page 6 TRITON 1 2 Programming Manual OEM Cycle Sequence OEM Cycle Sequence instructions allows the OEM to set the order of Cycle Options the cycle The OEM Softener System Setup or the OEM Filter System BACKWASH Serine at Set
28. rechargeable battery replaced Error Message If the word ERROR and a number are alternately flashing on the display contact the OEM for help This i3 indicates that the valve was not able to function properly Page 20 SET CLOCK NEXT REGEN REGEN DAY 2 CLOCK NEXT REGEN REGEN 342 SET CLOCK NEXT REGEN H DAY SET CLOCK NEXT REGEN DAY H SET CLOCK NEXT REGEN TIME j SET CLOCK NEXT REGEN SET CLOCK NEXT REGEN TRITON 1 2 Programming Manual Diagnostics STEP 1D Press A and V simultaneously for three seconds If screen in step 2D does not appear in 5 seconds the lock on the valve is activated To unlock press W NEXT A and SET CLOCK in sequence then press A simultaneously for 3 seconds STEP 2D Days since last regeneration This display shows the days since the last regeneration occurred Press NEXT to go to Step 3D Press REGEN to exit Diagnostics STEP 3D Volume since last regeneration This display shows the volume of water that has been treated since the last regeneration This display will equal zero if a water meter is not installed Press NEXT to g
29. rive History in the direction of extended STEP 9D MAV Drive History in the direction of retracted Form No V3435CC 1 23 2013 U S Patents 6 402 944 6 444 127 6 776 901
30. s total since start up This display shows the total days since startup Press NEXT to go to Step 4VH Press REGEN to return to previous step STEP 4VH Regenerations total number since start up This display shows the total number of regenerations that have occurred since startup Press NEXT to go to Step 5VH Press REGEN to return to previous step STEP 5VH Volume total used since start up This display shows the total gallons treated since startup This display will equal zero if a water meter is not installed Press NEXT to go to Step 6VH Press REGEN to return to previous step STEP 6VH Error Log This display shows a history of the last 10 errors generated by the control during operation Press A or V to view each recorded error Press NEXT to exit Valve History Press REGEN to return to previous step 3 Values in steps 2VH through 6VH cannot be reset TRITON 1 2 Programming Manual Page 23 Revision History 1 3 2013 PAGE 4 4 V3108CC 05BOARD WS1 THRU2L 2 CC PCB ALT REPLACE XMEGA 1 PAGE 5 To reset to defaults press NEXT and W simultaneously 1 Press REGEN once REGEN TODAY will flash on the display 2 Press and hold REGEN for three seconds until the valve regeneration initiates PAGE 6 Step 2CS PAGE 7 Step 4CS PAGE 9 Step 565 Allows selection of one of the following using or PAGE 10 Step 6CS 10CS delete the and buttons Added Step 11CS PAG
31. ss levels entered are used to automatically calculate reserve capacity when gallon capacity is set to AUTO Press NEXT to go to Step 8S Press REGEN to return to previous step Step 8S Set Volume Capacity using V A If value is set to AUTO capacity will be automatically calculated and reserve capacity will be automatically estimated oFF regeneration will be based solely on the day override set see Installer Display Settings Step 31 or e anumber regeneration initiation will be based off the value specified If oFF or a number is used hardness display will not be allowed to be set in Installer Display Settings Step 21 See Setting Options Table for more detail Press NEXT to go to Step 9S Press REGEN to return to previous step Step 9S Set Regeneration Time Options using V or A If value is set to NORMAL means regeneration will occur at the preset time on means regeneration will occur immediately when the volume capacity reaches 0 zero or NORMAL on 0 means regeneration will occur at one of the following the preset time when the volume capacity falls below the reserve or the specified number of days between regenerations is reached whichever comes first or immediately after 10 minutes of no water usage when the volume capacity reaches 0 zero NORMAL is the default if Step 465 is set to ALTA or and NORMAL 0 not available See Setting Options Table for more detail Pr
32. t to the brine tank if the salt remaining feature is activated the following steps must be completed NEXT REGEN SET CLOCK SALT FILL SET NEXT REGEN CLOCK STEP 3US SET LBS REMAINING SET CLOCK NEXT REGEN SET LBS e SET clock NEXT REGEN SET LBS eu SET CLOCK NEXT REGEN Step 1US Press NEXT until SALT appears in the display It does not matter if the SALT display alternates with the LBS REMAINING display Step 2US Press SET CLOCK Step 3US Set LBS REMAINING Use V or A to adjust the Ibs remaining in the brine tank NOTE Estimate the pounds of salt in the brine tank and add it to the amount of salt added to the brine tank The example at the left would indicate 200 Ibs of salt being added to a brine tank that has 40 Ibs remaining Step 4US Press SET CLOCK to exit Adding Salt RETURN TO NORMAL MODE Power Loss If the power goes out the system will keep time for 24 hours or until the battery is depleted If a power E outage of more than 24 hours occurs the time of day will flash on and off which indicates the time of day rruauor should be reset The system will remember the rest If a power outage lasts less then 24 hours and the time of day flashes on and off the time of day should be reset and the non
33. to previous step NOTE The display will flash between cycle number and time and brine direction dn Step 5S Select the time for the third cycle which in this example is RINSE using V or A Press NEXT to go to Step 6S Press REGEN to return to previous step Step 6S Select the LBS or MIN for the fourth cycle which in this example is FILL using or A When both 2 0 and 2 0L are options in Step 2CS and 2 0 is selected or MIN is selected in Step 11CS FILL is in minutes WS2 valves are shipped from the factory with a refill flow contol of 2 2 gpm 8 3 lpm Press NEXT to go to Step 7S Press REGEN to return to previous step Page 12 CAPACITY SET omt x 1000 SET 06 NEXT REGEN 1007 REGEN NEXT SET clock REGEN SETTIME REGEN NORMAL on L SET clock NEXT REGEN SET SALT NEXT RETURN TO NORMAL MODE SET CLOCK REGEN TRITON 1 2 Programming Manual Step 7S Set Grains Capacity using W or A The ion exchange capacity is in grains of hardness as calcium carbonate for the system based on the pounds of salt that will be used Calculate the pounds of salt using the fill time previously selected Grains capacity is affected by the fill time The grains capacity for the selected fill time should be confirmed by OEM testing The capacity and hardne
34. treated before the system goes through a REGEN TODAY will Flash if a regeneration regeneration cycle The third display shows the current treated water flow rate through the system If 1 0 is selected in Step 2CS an A in front of the flow rate indicates that the tank with the control valve on it is in service If b is displayed the tank with the in out head is in service The fourth display will show either dP or hold if the dP switch is closed The fifth display shows the pounds of salt remaining or flashes SALT fill when the calculated pounds of salt falls below a safety level The fifth display will not appear if the valve is a WS2 set up as a filter or if the Set Low Salt Warning is set to off see last step in OEM Softener System Setup The user can scroll between the displays as desired If the system has called for a regeneration that will occur at the preset time of regeneration the words REGEN TODAY will appear on the display If water meter is installed the word Softening or Filtering flashes on the display when water is being treated i e water is flowing through the system Page 17 SOFTENING REGEN TODAY CAPACITY REMAINING GAL REMAINING DAY SET CLOCK NEXT REGEN is expected Tonight SET CLOCK NEXT REGEN TIME SOFTENING 535 NEXT REGEN
35. up allow the OEM to set how long cycles will last The OEM may choose up to 9 cycles in any order END END must be used as the last cycle option The SERVICE cycle should only be used in brine prefill applications RINSE UP BRINE SOFTENING WS1 Only OR FILTERING The upflow cycle can not be used on the WS1 25 WS1 5 WS2L or WS2 control valves The V3407 piston used on the WS1 25 WS1 5 and WS2L is designed for downflow use only The components for converting the operation of a WS2 valve from downflow to upflow are not yet available For WS1 valves prior to selecting DN brine or UP brine or not selecting a regenerant flow cycle verify the correct valve body main piston regenerant piston and stack are being used and that the injector or injector plug s are in the correct locations See Valve Body Compliance Table in WS1 amp WS1 25 OEM Drawings and Service Manual The following is an example of how to set a valve so that when regeneration is initiated BACKWASH occurs first dn BRINE occurs second RINSE occurs third and FILL occurs fourth Step 1CS Press NEXT and simultaneously for seconds and release Then press NEXT simultaneously for 3 seconds and release If screen in Step 2CS does not appear in 5 seconds the lock on the valve is activated To unlock press W NEXT A and SET CLOCK in sequence then press NEXT and simultaneously for 3 seconds and release Then press NEXT and W simultaneously for ab 3 secon
36. xt Regen Set Time when the specified number of days between regenerations is reached Reserve capacity not automatically estimated An An Regeneration occurs at the next Regen Set Time when volume y NORMAL y capacity reaches 0 or the specified number of days between number number Eu regenerations is reached Reserve capacity not automatically estimated Regeneration occurs immediately when volume capacity reaches 0 AUTO OnO 0 Time of regeneration will not be allowed to be set because regeneration will always occur when volume capacity reaches 0 Reserve capacity not automatically estimated Any Regeneration occurs immediately when volume capacity reaches 0 number Time of regeneration will not be allowed to be set because regeneration will always occur on 0 Reserve capacity automatically estimated Regeneration occurs when volume capacity falls below the reserve AUTO NORMALonO oF gen bio Odd capacity at the next Regen Set Time or regeneration occurs after 10 minutes of no water usage when volume capacity reaches 0 Reserve capacity automatically estimated An Regeneration occurs at the next Regen Set Time when volume capacity AUTO NORMAL on 0 NUM falls below thereserve capacity orthe specified number of days between regenerations is reached or regeneration occurs after 10 minutes of no water usage when volume capacity reaches 0 Reserve capacity not automatically estimated Any Any Regeneration occurs at the next Regen Set Time when the spec