Home

USER AND SERVICE MANUAL

image

Contents

1. feel exactly the same if well cured For general guidance use recommended curing times below For reduced heat or shrinkage use Pulse Power Mode while doubling the recommended curing times below Recommended Cure Times seconds High Power Mode 3M A3E C6D 10 Two 10 Manufacturer Ivoclar Dentsply Resin Brand Color Shade Final layer Times Battery Care Keep FUSION charged at all times when not in use Connect DC Power Plug to Plug Receptor on the Charging Base Place Handpiece onto Charging Stand Secure Charging Stand on a table counter with Stand Stick Pad for ease of operation Alternatively connect DC Power Plug directly to the back end of Handpiece to charge P and power on the unit CJ l Cre 530 LCD screen lights green while charging LCD backlight turns off when fully charged Battery Bar displays three full bars when the battery is fully charged In normal operation Battery Bar drops from three to two bars while running and returns to full bar upon completion of a cycle DC Power Plug FUSION ce im Lens Module Techniques 7 Lens Module Use disposable Barrier Sleeves and Curing Caps to protect lenses from liquid and composite damages Replace Lens Module immediately if it a has cured resin b is scratched or cloudy Align and lock flat edge of Lens Tool optional accessary to flat edge of Lens Module Turn Lens Tool counter clockwise and unscrew Lens Module Clean mounting
2. thread Replace damaged lens with a new Lens Module by reversing the steps Barrier Sleeves Slide sleeve into Handpiece Twist body relative to sleeve for tight fit Light Shield Slide in Light Shield from the LED Light Head to the Handpiece into proper position for best access Tip Size Tip and beam size can be adjusted by selecting the proper size Curing Caps For small cavity treatment snap on 9mm Curing Cap and anchor light on occlusal or bonding surface For temporary bonding snap on 3mm Curing Cap Tacking Tip at the end of the Lens Module and apply pressure at the center of crown veneer for best contact Tack for 1 to 2 seconds then remove excess adhesives before final bonding For veneer bonding and molar cavity treatment snap on 13mm Curing Cap and place light in direct contact Tacking Tip Cleaning and Disinfecting Clean and disinfect Handpiece and Charging Stand with a soft cloth or tissue dampened with cleaning solution including Cavicide Lysol lsopropyl or Ethyl alcohol and equivalent AN Do not spray soak or autoclave Use Q tips to clean lens and electrical contacts by slightly dampening the tip do not soak with Isopropyl alcohol Safeguard Handpiece opening area Metal Keypad Charging Plug and Lens Module against liquid and sharp objects as this may cause electrical short circuit permanent optical damage or malfunction Optional Add ons FUSION is the most versatile LED light system all
3. Atmospheric pressure 0 5 atm to 1 0 atm 500hPa 1060hPa Measured absolute irradiance using calibrated optical spectrometer Limited Two Year WARRANTY Register your FUSION curing light at www dentlight com DentLight Inc extends a two year warranty against defects in material and workmanship to the original purchaser of this product from an Authorized dealer except the Battery Assembly and Charging Stand one year warranty This warranty is valid providing factory inspection indicates that any such defect was developed during normal and proper use DentLight shall under no circumstances be liable for incidental special consequential damages and damage from misuse including the following expressed or implied Improper operation accident or neglect misuse or abuse such as physical damage dents scratches etc Liquid water rain extreme humidity ultrasonic autoclaving Tampering improper repairs or modifications that have not been carried out by a certified Service Center Use of other spare parts and accessories other than from the manufacturer such as incorrect power adapter Other acts which are not the faults of DentLight For service call 1 800 763 6901 in US to obtain RMA number Fill out RMA form online and return as instructed In case of a warranty claim the complete apparatus must be returned Alternatively contact your dealer for service return Troubleshooting Guide Error Indication Possible Solutions 1 LCD i
4. ations LED Light Head 420 490nm Wavelength Violet Light Head 390 430nm White Light Head 5000 6500K Light Intensity LED Light Head High Power Mode 2700 Pulse Power Mode 2700 peak 1300 average O 20 Violet Light Head 1000 at light ti mW cm2 or lux White Light Head High Power Mode 110 000 lux with Tacking Exam Tip Power Adapter Input 100 240V 50 60Hz Output 5V 1 2A Battery performance Total light exposure time 35 45 minutes High Power 90 minutes full recharging time Continuous operation patient application curing duty cycle 10sec High Power Mode 20sec Pulse Power Mode ON 1minute OFF exam place inch 2 5cm away from soft tissue 60sec Pulse Power Mode ON 1 minute OFF Shutoff Timer auto shutoff User shut off anytime by pressing ON OFF Key Low battery auto shutoff Overheat auto shutoff Self protection shutoff is accompanied by warning backlight and audible beep as well as flashing THERMOMETER or BATTERY BAR symbols Equipment Class Symbol for class Il equipment o Safety IEC 60601 1 EMC Compliance IEC 60601 1 2 Protection from Electric shock Type BF Protection from ingress of liquids IPXO Operating environment Ambient temperature 50 F to 86 F 10 C to 30 C Relative humidity 10 80 non condensing Atmospheric pressure 0 5 atm to 1 0 atm 500hPa 1060hPa Storage environment Ambient temperature 14 F to 104 F 10 C to 40 C Relative humidity 10 80 non condensing
5. e Limitation a Date of Manufacturing Humidity Limitation Temperature Limitation For Licensed Dental Professional Use Only Serial Number REF Product Number Start Up Assemble Handpiece ant CL O op il Upon receiving your FUSION remove all components from the package and examine them If damage is apparent please contact your authorized DentLight distributor from whom your light was purchased Attach the Battery Assembly to the Main Control by screwing the Battery Assembly clockwise into the Main Control A short beep upon connection indicates that the light is battery powered and the LCD display should automatically power on Adjust the 360 swivel LED Light Head to a comfortable curing position and ensure good connection with the Main Control Light is now ready for use Operation and Setting FUSION uses advanced Metal Keypad and LCD interface ON OFF Key starts and stops the light TM PW Key sets the Operation Time and Power Mode FUSION defaults in High Power Mode white backlit LCD with steady MODE symbol Press TM PW Key to select a Digital Timer Press and hold TM PW Key for 2 seconds and release to change power to Pulse Power Mode green backlit LCD and flash MODE symbol and vice versa Press and hold ON OFF Key together with TW PW Key to go to sleep mode High Power Mode allows the fastest curing with plasma like energy dosage Pulse Power Mode maintains the peak power and generates the minimum heat by lower
6. e use only Discard properly after each use 5 DO NOT operate the unit in the proximity of flammable mixtures FUSION is not suitable for uses in the presence of a flammable anesthetic mixture with air or nitrous oxide Use in well ventilated area 6 Keep solvents flammable liquids and sources of intense heat away from FUSION as they may damage internal and external parts the seals or the buttons on the control panel 7 DO NOT autoclave or immerse unit in any kind of ultrasonic bath disinfectant cleaning solution or any kind of liquid Do not spray liquids directly onto the light and prevent liquids from entering FUSION open area such as Keypad Charging Stand and its connectors as this may damage or short circuit the device and can cause potential hazard for operator and or patient Glossary of Symbols A number of symbols are used on the device accessories and throughout this manual it is important that the user operator of FUSION understands the meaning of each symbol to avoid possible injury to the operator or and patient Please read before using this device Symbol is used to alert you to potential personal injuries and hazard Understand all safety messages that follow this symbol to avoid injury to the operator and or patient Type BF Applied Medical Equipment fo Protection Class Il Double insulated Waste Electrical and Electronics i y WEEE j Manufacturer European Authorized Representative a Atmospheric Pressur
7. ing the average power in half with a 50 50 on and off duty cycle Built in settings are shown in the table below After starting Digital Timer counts down and the light makes an audible beep every 5 seconds Press ON OFF Key anytime to stop Select 60 seconds timer for oral exam a Violet Light Head optional for cancer screening b White Light Head optional for caries and fracture detection ON OFF High Power Power Pulse Power ce ae CR Timer ON OFF MODE DIGITAL TIMER BATTERY BARS Backlit LCD Green To Change Press and hold TM PW Key for 2 seconds Power Mode and release TM PW Battery Protection Temperature Overheat Replace battery FUSION has built in self protection on low battery and overheats Low battery is indicated with low Battery Bars one or no bars y Low battery triggers one beep warning a minute ahead of self protection shutdown Light then goes to sleep mode m E Overheating is indicated with a flashing Thermometer symbol an E audible warning beep together with a red backlit LCD Light shuts off when overheat is triggered Thermometer Curing Recommendations For specific resin sealants and bonding materials perform a timed curing test outside the mouth using a 3mm washer or hardness disk Cure from the top for the recommended time and reverse the disk Using a sharp instrument compare the hardness of the disk to the hardness of the composite it should
8. m DentLigh Setting New Standards through Innovation a Q 9 z FUSION INSTRUCTIONS FOR USE LED Curing Light System Rev 4 Powered by Patented Focus Beam Technology Product Information Description and Indications for Use Fusion Curing Light System Rev 4 is a high power curing light device for polymerization of light cured materials by dental professionals It cures the wavelength range of 420 490 nm with the option to go down to 390nm These operating instructions provide recommendations and guidelines for the intended use of the light Please read them carefully System Components a i S FUSION Curing Light System consists A of Handpiece Charging Stand Curing eee Caps Power Adapter Light Shield aes LED Light Head Barrier Sleeves Stand Stick Pad and Instructions for Use Light Shield Quantity Description LED Light Head Main Control TE eee Main Control Battery Assembly LCD n Charging Stand Curing Caps 3mm 9mm 13mm each Power Adapter Light shield Barrier Sleeves 1 pack of 100 Stand Stick Pad Instructions for Use S a Barrier Sleeves Power Adapter Country Blade Charging Stand Plug Receptor m Battery Assembly DC Power Plu si z Stand Stick Pad Product Safety Warnings and Cautions fa Prior to installation and activation of the light please read these instructions carefully and follow safety 5 procedures as well as the
9. ns Module Focus X blank Silver B Blue P Pink G Gold Y US EU AU Australia DentLight Inc vl Emergo Group EMERGO EUROPE 1825 Summit Ave 210 Molenstraat 15 Plano TX 75074 US C 2513 BH The Hague Tel 800 763 6901 Netherlands Outside US 1 972 889 8857 Tel 31 0 70 345 8570 www dentlight com Fax 31 0 70 346 7299 Made in U S A FUSION is a trademark owned by DentLight 10 2013 v4 0 2013 DentLight
10. owing users to implement multiple functionalities from its advanced modular base kit In addition to the Standard LED Light Head that comes with the kit wavelengths from 420 490nm optional add on functions can be achieved with Violet Light Head providing violet light 390 430 nm for a oral lesion cancer screening b curing of lower wavelength initiator adhesives e g TPO and c composite visualization removal Oral screening enables early cancer detection using fluorescence generated from tissue and viewed through Fluorescence Viewer that comes with FUSION to DOE starter kit A Be sure to position the light 1 3 inches 2 5 7 5cm distance away from examined tissue White Light Head offering an exam probe light that outputs super high power transillumination best used with Tacking Exam Tip for detection of dental caries cracks and location of root canal Full arch Bleaching Attachment converting the light into a full arch bleaching light Bleaching Upgrade Kit includes the Full arch Bleaching Attachment Mouth Guard and a Flex arm that holds the Handpiece on the one side and clamps on the other side of the dental chair s head rest To operate in Bleaching Mode press and hold ON OFF Key for 3 seconds to select Bleaching Mode 15 minute Pulse Power Mode then press ON OFF to start uN CAUTION Be sure to use Mouth Guard and Bleaching Attachment during bleaching Product Specification Type of information Specific
11. s blank 1 Push any Key 2 Charge Battery Assembly alone by 2 Buzzing noise when charging directly plugging DC Power Plug bypassing Charging puso me Stand for 5 hours i DC Power Plug Light will not Head gets hot vacuun tip to the light tip or wait for cool down 1 Light does not activate with Key Contact manufacturer or your local dealer for service 2 Timer counts down yet no output light Light does not 1 One or no Battery Bars 1 Charge Handpiece directly bypass Charging Stand stay on for 2 Bad connection or contacts for 1 hour 2 Check connection pins to make sure that desired time they are not damaged If problems persist contact your dealer or Manufacturer for Service Light generates Patient feeling discomfort 1 Cure lt 10 seconds per layer 2 Direct an air stream too much heat from an air syringe or high speed vacuum tip 3 Adjust to Half Power Mode 4 Adjust curing distance Battery will not 1 Broken pins in Charging Stand 1 Bypass replace or service Charging Stand charge 2 Electronic defect in Battery Assembly 2 Replace or service Battery Assembly Reorder and Optional Item Codes REF Description REF Description 7600080 X FUSION Curing Light Kit X color 7500060 X LED Light Head X color code code 7500082 Barrier Sleeves 100 pack 7500060U Violet Light Head 7600081 Curing Caps 9mm 10 pack 7500060W White Light Head 7610081 Curing Caps 13mm 10 pack 7500093 Le
12. specific safety comments and recommendations presented throughout the instructions for use The manufacturer accepts no liability for any damage resulting from the improper use of this unit and or for any purpose other than those covered by these instructions 1 A CAUTION FUSION produces high intensity light Prolonged exposure to the skin oral mucosa or pulp can result in irritation or injury Do not place light in direct contact with unprotected gingival oral mucous membrane or skin Do not place light directly on the same tooth segment for more than 10 seconds in High Power Mode If long exposure cannot be avoided direct a stream of air over the tooth surface from an air syringe or high speed vacuum tip adjust to Pulse Power Mode or adjust curing distance 2 A CAUTION Do not look directly at light emitted from the device Do not use FUSION without suitable eye protection for the operator assistant and patient Use Light Shield Protective Goggles and or Curing Caps Exposure must be restricted to the area of the oral cavity for which the clinical treatment is intended 3 A CAUTION FUSION must be used with Single Use Barrier Sleeves to avoid cross contamination Replace Barrier Sleeve after each patient treatment is completed This sleeve also prevents composite material from adhering to the surface of the lens and degrading the curing performance 4 Products marked Single Use on the labeling are intended for singl

Download Pdf Manuals

image

Related Search

Related Contents

Page 1 Model: CH104 Model: CH2034 EZee Life™ Products 34  コミュニケーション機器、環境制御装置等のフォローアップ対応  User Manual - Topaz Systems Inc.  Sartorius Talent  VENUS series User Guide _Rev.04    Samsung NP900X3GI Brugervejledning (Windows 7)  VDC Digital Recorder User Manual  Computers and Sensors— Operation, Diagnosis, and Service  デジアイピース KDE-20D 取扱説明書  

Copyright © All rights reserved.
Failed to retrieve file