183G (GALVANIZED) 5, 10, and 15 GALLON ASME TANKS

image

Contents

1. K BINK 5 10 15 GALLON GALVANIZED TANK ASSEMBLIES PARTS LIST ITEM NO ON DU B Ut M O N C 25 Ae 39 Purchase locally KK 5014 Clamp Pin and Screw Kit includes 1 each of items 30 31 32 and 33 PART NO QMS 447 QMG 409 55G 8184 K2 KK 5042 QMG 19 TIA 5110 TIA 5040 QMG 21 55 2707 83 524 83 1207 VA 540 QMG 402 1 QM 1458 1 QMS 445 PTL 408 K20 PTL 412 K8 PTL 415 K10 QM 1352 KK 5014 QMG 505 1 QMG 510 1 QMG 515 1 HA 57011 SEE PAGES 8 amp 9 QS 5012 DESCRIPTION RETAINING NUT THRUST WASHER THRUST COLLAR SET SCREW 5 16 18 X 3 8 THRUST COLLAR KIT INCL 4 amp 5 BEARING ASSY PLAIN STEEL O RING KIT OF 2 SHAFT SEAL 5 8 I D INTERNAL RETAINING RING SHAFT SEAL KIT INCL 8 amp 9 PLUG NON AGITATED MODELS ONLY SAFETY VALVE ASSY 110 PSI SAFETY VALVE ASSY 40 PSI EXTRA SENSITIVE ONLY AIR MANIFOLD AIR RELIEF VALVE 1 4 NPT M FILL PORT CAP FILL PORT CAP GASKET STREET ELBOW 3 8 18 NPT Brass BALL VALVE 3 8 NPS OUTLET TANK LID TANK GASKET PLUG 1 2 14 NPT PLATED STEEL FLUID TUBE FLUID TUBE FLUID TUBE AGITATOR SHAFT AGITATOR SHAFT AGITATOR SHAFT AGITATOR PADDLE SOC HEAD CAP SCREW 5 16 18 X 1 1 4 S S AGITATOR PADDLE KIT INCL 24 amp 25 STATIONARY PADDLE STATIONARY PADDLE KIT INCL 25 amp 27 DISPOSABLE TANK LINER 5 GAL DISPOSABLE TANK LINER 10 GAL DISPOSABLE TANK LINER 15 GAL THUMB SCREW S
2. To reduce the risk of injury follow the pressure relief procedure below e Whenever the tank is left unattended e Before attempting removal of fill port cap or tank cover e Before checking or servicing any part of the spray system 1 Turn off the main air supply to the tank 2 Close the air inlet valve located on the tank air manifold 3 Bleed off air in the tank by turning the air relief valve 5 thumb screw counterclockwise Wait until all the air has escaped through the valve before removing the pressure tank cover or fill port cap 4 Leave the air relief valve open until you have reinstalled the tank cover or fill port cap K BINK 5 10 15 GALLON GALVANIZED TANK ASSEMBLIES SPECIFICATIONS amp OPTIONS SPECIFICATIONS 0 Y Air Manifold Steel Zinc Plate Plug Air Manifold Coupling Steel Zinc Plate Bottom Outlet Optional Kit 304 Stainless Steel 3 4 14 NPS M TANK CAPACITIES Actual Capacity 9 8 US Gallons 11 8 US Gallons 19 8 US Gallons No Regulation Air inlet pressure gauge only Standard Single Regulation Standard Double Regulation Extra Sensitive Regulation Extra Sensitive Regulation with Standard Gun Regulation AIR CONTROL OPTIONS APPLICATION Holding tanks Transfer tanks Used where precision fluid pressure control is not required Provides standard fluid pressure control only For use where precision control of both fluid and air pressures is not required Also Use
3. dirt pipe scale and most liquid aerosol Includes an automatic drain which expels liquids which accumulate in the filter bowl 29 3100 SCRUBS HAND CLEANER TOWELS Scrubs are a pre moistened hand cleaner towel for painters No water is needed 83 2924 FLUID Y STRAINER Attaches on fluid outlet of tank Includes 100 mesh filter screen Additional filter screens in other mesh sizes available DISPOSABLE TANK LINERS Molded polyethylene tank liners reduce solvent waste and tank cleanup time The liner is made of tough durable leakproof poly ethylene and can be used with all compatible materials PTL 408 K20 Kit of 20 tank liners 9 8 gal PTL 412 K8 Kit of 8 tank liners 11 8 gal PTL 415 K10 Kit of 10 liners 19 8 gal PROSPECTOR PRESSURE TANK STRAINERS FOR 5 10 AND 15 GALLON TANKS Prospector strainers are an economical way to remove foreign material from paint stain lacquer and coatings Inner Diameter 11 75 298 45mm Outer Diameter 15 375 390 52mm Height Depth 3 75 95 25mm Case QUY NC sssini nanena A 20 PTS 5Gal K20 200 200 micron approx 65 wire mesh PTS 5Gal K20 400 400 micron approx 37 wire mesh PTS 5Gal K20 600 600 micron approx 28 wire mesh 11 WARRANTY This product is covered by Binks 1 Year Limited Warranty Binks Sales and S
4. Defective fill port gasket 1 Fluid tube not sealed to lid Excessive agitation 1 Tighten fluid tube into lid Air mixing with paint Reduce speed of agitator K BINK 5 10 15 GALLON GALVANIZED TANK ASSEMBLIES NOTE Refer to SBBI 19 087 Use PTFE based thread sealant on all for information about air and fluid connections Open side of shaft seal 8 faces downward the drive unit ue m ACAUTON vacuum operation A CAUTION Use 40 PSI Safety Valve 12A with an extra sensitive regulator 12 or 12A t f m 13 JA 17 16 iS Ya NPS 1 NPS 20 gt el P 34 22 21 The Stationary Paddle Kit 28 ERN comes standard only on 10 and 15 gallon tanks 28 The 5 and 10 gallon tanks come standard with one Agitator Paddle Kit A PETROLEUM JELLY GREASE Me ee 26 26 T For bottom outlet Mw conversion remove and discard plu The 15 gallon 2 36 iii tanks come a standard with 26 ad 87i two Agitator S Paddle Kits 26 Grounding Diagram Purchase hardware locally f 5 16 18 Hex Head Nut 2 Required 5 16 18 x 3 4 Long Hex Head Bolt 1 Required Sufficient Length Agitator Regulator Hook Up with 12 Gauge Wire Extra Sensitive Regulation Not Shown 1 or 2 Regulators 4 5 16 Lock Washer Requires 40 PSI Safety Valve 12A 1 Required Tank Skirt Ref Agitator Regulator Hook Up with Standard Regulation 1 or 2 Regulators
5. on air supply Cup cloth over air cap on the gun and Open the fluid outlet valve Hol pull trigger This will force material back through the hose into the tank nA A vU N Turn handle on tank pressure regulator PREPARATION clockwise to pressurize tank 8 Empty and clean tank and parts that come into contact with material Use a solvent compatible with material being used Mix and prepare material to be used according to manufacturer s instructions Strain material through a fine mesh screen to remove lumps skin and Js foreign matter that might enter and clog fluid passages and or spray equipment 6 Turn on atomization air to spray gun at source of supply Test spray For further instructions consult literature provided with spray 9 gun Pour solvent into tank 10 Replace lid and tighten thumb screws If an air motor driven agitator is used and clamps start the agitator by slowly opening up the needle valve Air motor speed should be regulated according to the nature of the material being agitated Follow pressure relief procedure above 8 To add material to the tank remove the lid and pour directly into the tank or container 11 Spray until clean solvent appears 12 Repeat steps 4 through 8 If desired a U S or metric 1 gallon pail of fluid can be placed directly into the tank LUBRICATION Agitated Models MAINTENANCE Refer to the service manual provided with the air m
6. present in the spray area Keep tank at least 10 feet away from sources of ignition Ignition sources include hot objects mechanical sparks and arcing non explosion proof electrical equipment Ground the pressure tank by connecting one end of 12 gauge minimum ground wire to the pressure tank and the other end to a true earth ground Local codes may have additional grounding requirements See illustration on page 6 for grounding and grounding hardware required Never drill into weld or modify the tank in any way Do not adjust remove or tamper with the safety valve If replacement is necessary use the same type and rating of valve Read the label or data sheet for the material Do not use materials containing these solvents with galvanized pressure tanks Stainless steel tank models may be used with halogenated solvents Refer to specifications chart to ensure that fluids are chemically compatible with the tank wetted parts Before placing fluids or solvents in tank always read accompanying manufacturer s literature Operators should be given adequate training in the safe use and maintenance of the equipment in accordance with the requirements of NFPA 33 Chapter 15 in U S Users must comply with all local and national codes governing ventilation fire precautions operation maintenance and housekeeping in the U S these are OSHA sections 1910 94 and 1910 107 and NFPA 33 PRESSURE RELIEF PROCEDURE
7. EE ITEM 34 COTTER PIN 1 8 DIA X 1 LG SEE ITEM 34 CLEVIS PIN SEE ITEM 34 CLAMP SEE ITEM 34 CLAMP PIN amp SCREW KIT TANK amp LUG ASSY 5 GAL TANK amp LUG ASSY 10 GAL TANK amp LUG ASSY 15 GAL BOTTOM PLUG AIR HOSE ASS Y INCL W ITEM 39 AIR CONTROL AIR MOTOR GEARBOX DRIVE 5 GAL QTY 1 2 10 GAL QTY 1 2 A Items available separately or as a complete agitator assembly QMG 418 for 5 gallon tanks QMG 419 for 10 gallon tanks QMG 420 for 15 gallon tanks 15 GAL QTY 1 2 K BINK 5 10 15 GALLON GALVANIZED TANK ASSEMBLIES AIR CONTROL 4 SINGLE REGULATOR AIR CONTROL Control tank pressure only 85 470 for non agitated tanks 85 471 for agitated tanks tems with an asterisk are for use with an agitator ITEM PART NO NO DESCRIPTION 85 470 85 471 1 HAR 511 AIR REGULATOR 1 1 2 0 BUSHING STL PLTD 3 8 m x 1 4 f 2 2 3 VA 542 BALL VALVE 2 2 4 83 1290 GAUGE 150 PSI 1 1 5 SSP 8217 ZN SWIVEL ADAPTER 1 1 6 0 1 4 NPT PLUG SUPPLIED W REGULATOR 1 7 H 2008 NIPPLE 1 4 NPS x 1 4 NPT 1 8 SSP 30 ZN SWIVEL ELBOW 1 4 NPS m x 1 4 NPS sw 1 e Purchase locally Refer to 77 2781 for regulator service parts DOUBLE REGULATOR AIR CONTROL Control tank pressure and spray gun atomization pressure P Pe 85 472 for non agitated tanks 85 473 for agitated tanks tems with an asterisk are for use with an agitator pu e B
8. PPLIED W REGULATOR 7 83 4233 D M NIPPLE 1 4 x 3 8 8 HAR 507 AIR REGULATOR 9 83 1355 GAUGE 100 PSI ePurchase locally EM AIR IN EXISTING REGULATOR QMS 4003 NO REGULATION KIT Use when fluid pressure in tank is regulated by some other separate method of control ITEM PART NO NO DESCRIPTION QTY 1 e ADAPTER 1 4 NPT F X 1 4 NPS SW 1 2 e STREET TEE 1 4 3 83 1290 GAUGE 150 PSI 1 4 VA 542 BALL VALVE 1 ePurchase locally AIR IN BOTTOM OUTLET KIT BOTTOM OUTLET KIT WITH LEGS Allows conversion of tank from standard top outlet to bottom outlet All bottom outlet wetted parts are stainless steel 183 3001 for 5 10 and 15 gallon tanks with 34 bottom outlets Includes three 183 3005 Leg Kits Inward orientation P wi ITEM PART CG Outward orientation NO NO DESCRIPTION QTY ra 1 ADAPTER 3 4 NPT NPS UNIVERSAL 2 2 ELBOW 3 4 NPT F 1 3 PIPE NIPPLE 1 Legs can be oriented either inward or outward to provide 4 m BALL VALVE 3 4 NPT FULL PORT 1 flexibility in mounting 5 183 3005 LEG KIT 3 10 K BINK ACCESSORIES VS 534 FLUID STRAINER Primary fluid strainer that attaches between fluid outlet valve and fluid hose to strain material Components made of stainless steel with a nylon filter Comes standard with 100 mesh screen For more information see SB 7 072 HFRL 508 HFRL 509 CLEAN AIR CONTROL UNITS These units are designed to remove
9. RAINING All personnel must be trained before operating finishing equipment EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture malfunction or start unexpectedly and result in serious injury DE ENERGIZE DEPRESSURIZE DISCONNECT AND LOCK OUT ALL POWER SOURCES DURING MAINTENANCE Failure to De energize disconnect and lock out all power supplies before performing equipment maintenance could cause serious injury or death HIGH PRESSURE CONSIDERATION High pressure can cause serious injury Relieve all pressure before servicing Spray from the spray gun hose leaks or ruptured components can inject fluid into your body and cause extremely serious injury PRESSURE RELIEF PROCEDURE Always follow the pressure relief procedure in the equipment instruction manual KEEP EQUIPMENT GUARDS IN PLACE Do not operate the equipment if the safety devices have been removed AUTOMATIC EQUIPMENT Automatic equipment may start suddenly without warning INSPECT THE EQUIPMENT DAILY Inspect the equipment for worn or broken parts on a daily basis Do not operate the equipment if you are uncertain about its condition NEVER MODIFY THE EQUIPMENT Do not modify the equipment unless the manufacturer provides written approval KNOW WHERE AND HOW TO SHUT OFF THE EQUIPMENT IN CASE OF AN EMERGENCY STATIC CHARGE Fluid may develop a static charge that must be dissipated through proper grounding of the equipment objects to be spr
10. a BIliKS 183G GALVANIZED 5 10 and 15 GALLON a ASME TANKS Important Read and follow all instructions and SAFETY PRECAUTIONS before using this equipment Retain for future reference 7 DESCRIPTION ACTUAL CAPACITIES Binks pressure feed tanks are 5 Gallon holds 9 8 gallons or a 5 gallon pail intended for use as a pressure 10 Gallon holds 11 8 gallons container to supply material at a constant preset pressure up to a maximum of 110 psi The tanks are built to ASME specifications Also certified for vacuum operation 15 Gallon holds 19 8 gallons GALVANIZED 5 GALLON MODELS 183G 543 Extra Sensitive w gun regulation Gear reduced Heavy duty GALVANIZED 10 GALLON MODELS Replaces Part Part Sheet Sheet 77 2928R 2 77 2928R 3 K BINK In this part sheet the words WARNING CAUTION and NOTE are used to emphasize important safety information as follows A WARNING Hazards or unsafe practices which could A CAUTION Hazards or unsafe practices which could result in minor personal injury product or property damage Important installation operation or result in severe personal injury death or maintenance information substantial property damage A WARNING Read the following warnings before using this equipment READ THE MANUAL Before operating finishing equipment read and understand all safety operation and maintenance information provided in the operation manual OPERATOR T
11. ayed and all other electrically conductive objects in the dispensing area Improper grounding or sparks can cause a hazardous condition and result in fire explosion or electric shock and other serious injury WEAR SAFETY GLASSES Failure to wear safety glasses with side shields could result in serious eye injury or blindness 00 e e 5 0049 6 Meo GET IMMEDIATE MEDICAL ATTENTION To prevent contact with the fluid please note the following a Never point the gun valve at anyone or any part of the body b Never put hand or fingers over the spray tip C Never attempt to stop or deflect fluid leaks with your hand body glove or rag d Always have the tip guard on the spray gun before spraying e Always ensure that the gun trigger safety operates before spraying f Always lock the gun trigger safety when you stop spraying MEDICAL ALERT Any injury caused by high pressure liquid can be serious If you are injured or even suspect an injury a Go to an emergency room immediately b Tell the doctor you suspect an injection injury c Show the doctor this medical information or the medical alert card provided with your airless spray equipment d Tell the doctor what kind of fluid you were spraying or dispensing e Refer to the Material Safety Data Sheet for specific information WEAR RESPIRATOR Toxic fumes can cause serious injury or death if inhaled Wear a respirator as recommended by the fluid an
12. d solvent manufacturer s Material Safety Data Sheet TOXIC FLUID amp FUMES Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin inhaled injected or swallowed LEARN and KNOW the specific hazards or the fluids you are using FIRE AND EXPLOSION HAZARD Improper equipment grounding poor ventilation open flame or sparks can cause hazardous conditions and result in fire or explosion and serious injury PROJECTILE HAZARD You may be injured by venting liquids or gases that are released under pressure or flying debris ELECTRIC SHOCK GROUNDING Improper grounding or sparks can cause a hazardous condition and result in fire explosion or electric shock and other serious injury PINCH POINT HAZARD Moving parts can crush and cut Pinch points are basically any areas where there are moving parts NOISE HAZARD You may be injured by loud noise Hearing protection may be required when using this equipment PROP 65 WARNING WARNING This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm IT IS THE RESPONSIBILITY OF THE EMPLOYER TO PROVIDE THIS INFORMATION TO THE OPERATOR OF THE EQUIPMENT FOR FURTHER SAFETY INFORMATION REGARDING BINKS AND DEVILBISS EQUIPMENT SEE THE GENERAL EQUIPMENT SAFETY BOOKLET 77 5300 K BINK 5 10 15 GALLON GALVANIZED TANK ASSEMBLIES SAFEGUARDS The following hazards may occur
13. d where atomization air can be taken from filter regulator air lines Precision control for use with materials that are best applied at low closely controlled fluid and atomization air pressures Used with portable air compressors or with air lines when no other means of air pressure regulation is available Provides extremely accurate low pressure fluid pressure control Provides extremely accurate low pressure fluid pressure control plus precision control of spray gun atomizing air AGITATION OPTIONS No Agitation Materials that require minimal or no mixing and or readily hold any solids in suspension Heavy duty agitator for medium to high viscosity materials that require mixing and or solids suspension Gear reduced Drive Agitation K BINK 5 10 15 GALLON GALVANIZED TANK ASSEMBLIES OPERATION amp SERVICE CHECKS AWARN le OPERATION 4 Loosen thumb screws 17 tip clamps E 1 Close the air inlet valve to tank Turn 16 back and tip lid 11 to one side i a ou nity of tank Do not remove lid from tank mM handle on regulator counterclockwise Pressure is maintained in a pressure tank until spring tension is relieved P Mosen sp PUPPI TUNI after the system has been shut down Follow the pressure relief procedure on page 3 before opening the lid or fill port or performing maintenance on the tank Turn on air supply to the tank Open the air inlet valve to the tank ring about three turns Turn
14. during the normal use of this equipment Please read the following chart HAZARD CAUSE SAFEGUARDS Fire Pressure tank VS K s Explosion Hazard Pressure Tank Static Electricity M Explosion Hazard Pressure Tank Rupture M Explosion Hazard Galvanized Tanks Material Compatibility M General Safety A WARNING High pressure can cause serious injury Pressure is maintained in a pressure tank after the system has been shut down Always follow this procedure to relieve pressure from the tank Solvents and coatings can be highly flammable or combustible especially when sprayed Vapors from flammable liquids can catch fire or explode Static electricity is created by the flow of fluid through the pressure tank and hose If all parts are not properly grounded sparking may occur Sparks can ignite vapors from solvents and the fluid being sprayed Making changes to a pressure tank will weaken it Halogenated hydrocarbon solvents for example 1 1 1 Trichloroethane and methylene chloride can chemically react with aluminum parts and components and cause an explosion hazard These solvents will also corrode the galvanized tank coating Improper operation or maintenance may create a hazard 1 Adequate exhaust must be provided to keep the air free of accumulations of flammable vapors 2 Smoking must never be allowed in the spray area 3 Fire extinguishing equipment must be
15. ervice www binks com Binks Binks has authorized distributors throughout the world For technical assistance or the distributor nearest you see listing below U S A Canada Customer Service Office 195 Internationale Blvd Glendale Heights IL 60139 Toll Free Telephone 1 800 992 4657 U S A and Canada only Toll Free Fax 1 888 246 5732 ed gt EITVIIK E DeVilbiss Automotive Refinishing Binks has authorized distributors throughout the world For equipment parts and service check the Yellow Pages under Automotive Body Shop Equipment and Supplies For technical assistance see listing below U S A Canada Customer Service Office 11360 S Airfield Road Swanton OH 43558 Toll Free Telephone 1 800 445 3988 U S A and Canada only Toll Free Fax 1 800 445 6643 12 12 2012 Binks All rights reserved Printed in U S A
16. o ye ITEM PART SAIR IN NO NO DESCRIPTION 85 472 85 473 w 1 HAR 511 AIR REGULATOR 1 1 2 e ea BUSHING STL PLTD 3 8 m x 1 4 f 2 2 11 a w 3 VA 542 BALL VALVE 2 Z 4 83 1290 GAUGE 150 PSI 1 1 5 SSP 8217 ZN SWIVEL ADAPTER 1 1 6 MEME LL 1 4 NPT PLUG SUPPLIED W REGULATOR 2 1 7 83 4233 D M NIPPLE 1 4 x 3 8 1 1 8 HAR 507 AIR REGULATOR 1 1 9 83 1355 GAUGE 100 PSI 1 1 10 H 2008 NIPPLE 1 4 NPS x 1 4 NPT 1 11 SSP 30 ZN SWIVEL ELBOW 1 4 NPS m x 1 4 NPS sw 1 e Purchase locally Refer to 77 2781 for regulator service parts Refer to SBBI 6 147 for regulator service parts K BINK 5 10 15 GALLON GALVANIZED TANK ASSEMBLIES EXTRA SENSITIVE AIR CONTROL EXTRA SENSITIVE REGULATOR AIR CONTROL E SINGLE REGULATOR an 6 8 MES 7 p Provides extremely high precision control of tank pressure 9 gf only from 0 30 PSI Includes 40 PSI Safety Valve not shown x p CS 37 7 o A 85 490 for non agitated tanks 85 491 for agitated tanks AIR IN tems with an asterisk are for use with an agitator g Pa a M E ITEM PART ete 92 N N 0 0 020 g 1 HAR 501 EXTRA SENSITIVE REGULATOR 1 1 2 7000 BUSHING STL PLTD 3 8 m x 1 4 f 2 2 3 SSP 2629 ZN MALE BRANCH TEE 1 ANPT 1 1 TO TANK 4 SSP 8217 ZN SWIVEL ADAPTER 1 1 5 83 1414 GAUGE 30 PSI 1 1 6 e 7000 1 4 NPT STREET TEE 1 2 7 H 2008 NIPPLE 1 4 NPS x 1 4 NPT 1 8 SSP ZN 30 SWIVEL ELBOW 1 4 NPS m
17. otor for lubrication information To clean equipment proceed as follows Replace the lid assembly and tighten T ff the ai ly thumb screws 17 securely cid d The bearings in the agitator bearing assembly are impregnated with special non gumming oil Additional lubrication is not required 2 Follow th lief dure The air supply to the tank should include d RCM MED a filter water separator to filter dirt from the air and remove water and oil 3 Turn T handle adjusting screw on tank fluid pressure regulator counterclockwise until no spring Connect the material hose to the fluid pressure is felt outlet ball valve 8 The agitator shaft seal does not require lubrication SERVICE CHECKS Air escaping from port on regulator cap Broken or damaged diaphragm Replace diaphragm Pressure creepage registered on gauge Dirty or worn valve seat in regulator Clean or replace valve seat Material tends to settle out rapidly Not enough agitation of material Increase agitation Air leakage at agitator seal Defective seal assembly Replace Paint level in tank too high Keep fluid level under bearing ass y Paint getting into bearing assembly of agitator Defective agitator shaft seal Replace Thumb screw not tight Tighten Fluid or air leak at lid gasket Replace Defective lid gasket 1 Fill port cap not tight 1 Tighten Replace Fluid or air leak at fill port gasket
18. x 1 4 NPS sw 1 9 VA 542 BALL VALVE 2 2 10 TIA 5040 SAFETY VALVE 40 PSI NOT SHOWN 1 e Purchase locally Refer to SB 6 131 for regulator service parts EXTRA SENSITIVE REGULATOR AIR CONTROL DOUBLE REGULATOR Provides extremely high precision control of tank pressure plus 9 standard regulation for a spray gun Includes 40 PSI Safety Valve Not shown 85 492 for non agitated tanks i 85 493 for agitated tanks lt amp tems with an asterisk are for use with an agitator AIR IN 9 ITEM PART NO NO DESCRIPTION 85 492 85 493 1 HAR 501 EXTRA SENSITIVE REGULATOR 1 1 2 LN BUSHING STL PLTD 3 8 m x 1 4 f 2 2 3 SSP 2629 ZN MALE BRANCH TEE 1 4NPT 1 1 4 SSP 8217 ZN SWIVEL ADAPTER 1 1 5 83 1414 GAUGE 30 PSI 1 1 6 c 1 4 NPT STREET TEE 1 2 7 H 2008 NIPPLE 1 4 NPS x 1 4 NPT 1 8 SSP ZN 30 SWIVEL ELBOW 1 4 NPS m x 1 4 NPS sw 1 9 VA 542 BALL VALVE 2 2 10 e 1 4 NPT PLUG SUPPLIED W REGULATOR 2 2 11 83 4233 D M NIPPLE 1 4 x 3 8 1 1 12 HAR 507 AIR REGULATOR 1 1 13 83 1355 GAUGE 100 PSI 1 1 14 TIA 5040 SAFETY VALVE 40 PSI NOT SHOWN 1 1 e Purchase locally Refer to SB 6 131 for regulator service parts Refer to SBBI 6 147 for regulator service parts as BINK 85 469 CONVERSION TO DOUBLE REGULATOR ASSEMBLY KIT Convert standard single regulator or extra sensitive air control to a double regulator air control ITEM PART NO NO DESCRIPTION QTY 6 e 1 4 NPT PLUG SU