1. RJ 45 RJ 45 Connector Part Signal Connector Pin No Pin No 4 1 D Channel data 5 26 0 6 27 Sync line 3 2 4 4 D Channel data 5 29 1 12345678 6 30 Sync line 3 5 4 7 D Channel data RJ 45 CONNECTOR 5 J 32 6 33 Sync line 3 8 CONNECT TO ANY PORT ON 4 10 ANY 8BSI CARD D Channel data NB POLARITY IS IMPORTANT 5 3 35 6 36 Sync line 3 11 4 13 D Channel data 5 38 4 6 39 Sync line 3 14 4 16 D Channel data 5 41 5 6 42 Sync line 3 17 4 19 D Channel data 5 44 6 6 45 Sync line 3 20 4 22 D Channel data 5 47 7 6 48 Sync line 3 23 Figure 5 7A MDF Connections RJ 45 Page 5 10 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 5 Connecting Trunk Line Circuits RG 45 MODULAR CONNECTOR TO 8BSI and DBS CONNECTOR 1 8 2 7 3 La 6 4 A 5 5 Ee A 6 Leef 3 7 2 8 1 8BSI Connector DBS Connector Mudular RJ 45 CABLE 2pr twisted THICKNESS 0 6mm or 0 4mm MAX LENGTH 600m with 0 6mm diameter 400m with 0 4mm INTERFACE 2 x U interface amp 64 Kbit sec via 4 B channels Figure 5 7B Cables Between DBS and 8BSI RJ 45 to RJ 45 SAMSUNG Electronics Co Ltd Page 5 11 CHAPTER 5 Connecting Trunk Line Circuits OfficeServ 500 Installation Guide Ed 01 9 Connecting WBS24 with 8WLI Wireless LA
2. MECH i i bh SCM i MEM RCM MECH H t MISC Figure 3 1 MCP Card 12 LEDs give operational status of the CPU SmartMedia status LAN status and the status of card slots 1 9 These are stenciled on the face of the MCP card The LED indications are as follows Page 3 2 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 3 Installing Printed Circuit Cards LED Indications for M Version System MP OFF indicates the MCP card is powered down ON indicates the MCP card is booting Flicker Indicates normal operation SM OFF indicates the SmartMedia card is not installed or not recognized ON indicates the SmartMedia card is inserted and recognized Flicker indicates the SmartMedia card is being accessed LAN OFF indicates a LAN is not installed or power is off ON indicates the LAN board is booting Flicker indicates normal operation S1 S9 OFF indicates all circuits idle or no card installed ON indicates one or more circuits busy Flicker indicates the card has a fault or is inserted in the wrong slots e g TEPRI PRI BRI card must be inserted in the slot 1 or 2 or 3 otherwise LED flickers LED Indications for L Version System MP OFF indicates the MCP card is powered down ON indicates the
3. Figure 3 20 TEPRI Card Screw Location Page 3 36 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 3 Installing Printed Circuit Cards 31 AUTO ATTENDANT CARD This card has no selectable options but is under software control Insert up to and including five AA cards into any universal card slots Push firmly in the middle of both card ejectors on each card to ensure that it is fully inserted into the back plane connector There is no connector on the front of this card O BAR CODE u37 u31 u19 n A n 5 U24 U13 u3 Es ua P em Figure 3 21 AAUCD Card Do not insert this card with system power ON NOTE SAMSUNG Electronics Co Ltd Page 3 37 CHAPTER 3 Installing Printed Circuit Cards OfficeServ 500 Installation Guide Ed 01 32 SVMi 8 Note before installing this card it should be correctly configured with a hard disk drive and the appropriate number of voice processing modules One additional Voice Processing Module can be added The SVMi 8 card is installed in any universal slot of any cabinet Only one SVMi 8 can be installed in an OfficeServ 500 system and it counts as eight 8 stations of the power supply rating Check that the cabinet power switch is in the OFF position Next position the SVMi 8 card in the grooves of the card guide and gently slide the card
4. Switch No OFF ON 1 E1 T1 2 T1 E1 PRI 3 24B D 24B 4 USER NETWORK 5 AFT 6 Not Used Not Used 7 Not Used Not Used 8 Reserved Default i You must set the switch 8 as ON NOTE 30 2 TEPRI LED Definitions Status LED Name Function Normal Status Error Status SYN Synchronization Loss Indicates wander or loss OFF ON of framing LOS Loss of Signal No PCM Clocking is being OFF ON received AIS Alarm Indicating Signal Indicating that all one s OFF ON are being received L2 Layer 2 is active PRI messaging is being ON OFF received IPC IPC link set up OFF IPC link set up CLK Card clock status OFF CARD is secondary source ON card is primary source MODE LED s TP1 amp TP2 show the span type TP1 TP2 E1 mode OFF OFF E1 PRI mode OFF ON T1 mode ON OFF T1 PRI mode ON ON SAMSUNG Electronics Co Ltd Page 3 35 CHAPTER 3 Installing Printed Circuit Cards OfficeServ 500 Installation Guide Ed 01 si P PI I E R SYN LOS aa B AIS QQ L2 IPC QO CLK TP1 OO TP2 ITIPRI P14 El P15 PI P11 m sw2 O ye SI y i P SWI JP2 P13 Figure 3 19 TEPRI Card Ejector Tabs Screw Location
5. Index Phone No Converted No SZ Max MB 01 21 09221 4 7 Y 02 22 09222 4 7 Y 03 23 09223 4 7 Y 04 24 09324 4 7 Y 05 25 09325 4 7 Y 06 26 09426 4 7 Y 07 51 09251 4 7 N SAMSUNG Electronics Co Ltd gt The station call of the system B gt The station call of the system C gt The station call of the system D gt The station group call of the system B Page 12 15 CHAPTER 12 Networking Description and Programming Procedure OfficeServ 500 Installation Guide Ed 01 Index 52 09352 4 7 09 53 09453 4 7 N gt The station group call of the system D N The station group call of the system C Program 714 Enter the Conversion Table of Dialling a Station Directly MCP MCP2 Entry Digit MOH gt 1 6 CW Delete Name 001 2 B 0 gt 2100 2699 are applicable 002 BE B 0 gt Calls Attendant and Voice mail 003 9 9 1 Program 310 Set Auto Route Selection Class Set LCR class of all stations as 2 Program 603 trunk line Group MCP MCP2 800 Set trunk line connected to trunk line along with the PRI not set as the networking 801 Set PRI of TEPRI connected to System B through Networking 802 Set PRI of TEPRI connected to System C through Networking 803 Set VoIP Networking Signaling trunk line Program 710 Enter a Digit for Auto Route Selection MCP MCP2 Index Digit Length
6. rire 5 1 TRUNK LINES LOOP START ine 5 2 ES M TIE LINES acri 5 4 OFF PREMISE EXTENSIONS OPX r rire 5 5 ETPRICIRCU AAA onu o a aa eE aa a e Ea Sa AEAEE dant aaan eege 5 6 ISDN BRE LINES eene eines fanresenimacnncemetasc conne eege GEES 5 7 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 Table Of Contents T ISDN PRILINES eege ebe Eeer 5 9 3 SBS Men BEE 5 9 9 Connecting WBS24 with 8 WLl oonncinnniinnn iconos 5 12 CHAPTER 6 Connecting Station Equipment 1 SAFETY PRECAUTION S cool 6 1 2 AUDE REINER 6 1 3 OfficeServ 500 ADD ON MODULES AOM iii 6 3 4 cida TE E 6 4 5 SINGLE LINE TELEPHONES niiae alieni 6 5 6 DOOR PHONE AND DOOR LOCK RELEASE ns 6 7 1 DECT STATION cocina 6 8 7 1 DECT Station Overview ina iii 6 8 7 2 Block Diagram of DECT Structure in OfficeServ 500 M 6 8 7 3 Block Diagram of DECT Structure in OfficeServ 500 L eee ceeeeeeeeeeeseeeeeeneeeeees 6 9 7 4 Capacity of the DECT in OfficeServ DO 6 9 8 WBS24 Wireless Base Station 2 4GHz For future Application 6 11 9 ISDN STATION ISDN PHONE G4 FAX Etc 6 12 CHAPTER 7 Connecting Optional Equipment 1 MUSIC ON HOLD BACKGROUND MUSIC rrrrriie rie cieca 7 1 2 EXTERNAL PAGING ioscisccscciccsccsacienccctsncictecdsnciedstdvacenduaceaccadsaduudanes
7. PSU B PSU B PSU60 Slot1 Slot2 Slot3 Slot4 Slot5 Hop Slot7 Slot amp Slot9 SCP MCPILCP PSU B PSU B PSU60 Slot1 Slot2 Slot3 Slot4 Slot5 Slot Slot7 Slot8 Slotg SCP MCPILCP Figure 7 4 SIO Port Locations SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 7 Connecting Optional Equipment IOM BOARD PRINTER RXD 2 TXD 3 GND 5 DTR 4 Figure 7 5 PIN Connections for IOM Board to Printer IOM BOARD PC COM1 COM2 o aree 2 3 TXD 3 3 2 OR GND 5 5 7 DTR 4 9 PIN 25 PIN Figure 7 6 PIN Connections for IOM Board to Personal Computer When connecting customer supplied IT equipment to the IOM card serial ports an approved Data Isolation Unit must be installed CAUTION SAMSUNG Electronics Co Ltd Page 7 5 6 Page 7 6 CHAPTER 7 Connecting Optional Equipment OfficeServ 500 Installation Guide Ed 01 PC PROGRAMMING The OfficeServ 500 can be programmed with a PC equipped with DPAP PCMMC connected to the IOM LAN port LAN card must be installed on the MCP card or via one of the IOM serial ports see Figure 7 4 PC programming using the LAN port requires a data cross over cable if connecting directly to the LAN port or a standard data cable if connecting via a LAN In both cases the OfficeServ 500 IP address and PC IP address PCMMC ADDRESS must be programmed in MMC 830 T
8. Table 6 2 Call Channel Status Display Call Channel LD1 LD2 NONE Off Off BCH1 Blinking Off BCH2 Steady Off BCH3 Steady Blinking BCH4 Steady Steady 9 ISDN STATION ISDN PHONE G4 FAX etc The OfficeServ 500 BRI card supports S bus ISDN Station Interface mode for connection to ISDN Terminal equipment TE This ISDN station mode must be programmed in MMC 423 and a DN allocated to ISDN station ports using MMC 424 For ISDN TE that require power supplied by the OfficeServ 500 system this can be programmed in MMC 419 however a BRIN card must be installed After programming related to BRI configuration restart the BRI card using MMC 419 Refer to OfficeServ 500 Programming Guide for a detailed description Using 2 pair twisted 0 50 mm cable cross connect each ISDN TE to a BRI S bus port see Figure 5 6B Page 6 12 SAMSUNG Electronics Co Ltd CHAPTER 7 Connecting Optional Equipment 1 MUSIC ON HOLD BACKGROUND MUSIC Connect each customer provided music source to the music input on a MISC daughter board see Figure 7 1 Each trunk line can be programmed to receive a music source system generated tone or NO MUSIC when it is put on hold See MMC 408 Each phone can receive a music source or NO MUSIC for background music See the Programming Guide for instructions MMC 308 MISC 1 8 CONDUCTOR E PLUG CUSTOMER PROVIDED MISC 2 MUSIC SOURCE 1 CUSTOMER PROVIDED MUSIC SOURCE 2 Figure 7 1 MD
9. oc Pl S1 R2 CID Figure 3 14 RCM Board SAMSUNG Electronics Co Ltd Page 3 21 CHAPTER 3 Installing Printed Circuit Cards OfficeServ 500 Installation Guide Ed 01 14 MODEM BOARD This board has no selectable options and installs on the IOM board see Figure 3 15 The MODEM board provides a 56Kbps V90 modem for communicating with the system remotely Place the modem board face down over the two connectors taking care to properly line them up and lining up the holes in the MODEM board and IOM board and press gently on the back of the board to seat it Figure 3 15 Modem Board Page 3 22 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 3 Installing Printed Circuit Cards 15 IOM BOARD This board has no selectable options and installs on the system main cabinet see Figure 3 16 Line the IOM board up with the card slot and slide it in Press gently on the center of the IOM board front panel to seat it and secure the board with the two screws 000000000000000 Line up holes oA when installing modem MODEM 000000000000000 P4 P5 P6 P7 P8 UU U U IU U a gt amp Ld SIO1 SIO2 S103 SIO4 LA Mounting Screws Figure 3 16 IOM Board IOM Board gt gt
10. 5 13 MDF Connections Digital phone to DLI Card 6 2 IP Telephone connection diagram nenne 6 4 MDF Connections Single Line Telephone to SLI Card ooonooccnncccnicccncccccccnno 6 6 MDF Connections Door Phone and DPIM to DLI Card 6 7 MDF Connections RJ 45 to BBSI Card 6 10 MDF Connections MOH Source MISC Board n 7 1 MDF Connections Paging Loud Bell AMP to MISC Board 7 2 MDF Connections Common Bell to MISC Board n 7 3 SIO Port Locations iaia ari 7 4 PIN Connections for IOM Board to Pinter 7 5 PIN Connections for IOM Board to Personal Computer 7 5 Programming PC connection through LAN port for MCP card 7 6 Programming PC connection through LAN port for MCP2 card 7 6 Reserve Power Battery Connections 7 9 Cabinet Slot Numbers rs 10 3 OfficeServ 500 Networking Conceptual DiagraM oooooocccnnnccccnoccccnncccccnnnnos 12 1 Networking Programming Example for Each Point 12 14 LED Display of the MGI3 Card 3 45 LED Status Display alii iii alii 6 12 Call Channel Status Display canon nnnnnnnnnn 6 12 SAMSUNG Electronics Co Ltd CHAPTER 1 Site Requirements 1 SITE REQUIREMENTS When you are planning the installation of the O
11. SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 12 Networking Description and Programming Procedure 2 5 3 Program 713 Enter a Dial Conversion Table for Auto Route Selection MCP MCP2 001 0919 gt The first digit 9 added number is sent to the system A for outgoing through trunk line Program 825 ADD Number To Name Yes Use Remote Voice Mail Yes Remote VM Number 5049 System C Programming Program 820 Set System Link Number MCP MCP2 Index Link ID Signal GW SELF 093 SYS01 091 168 219 100 100 SYS02 092 168 219 110 110 SYS03 094 168 219 120 120 Program 821 Set Networking trunk line Set TEPRI card connected with System A as Q Signaling Program 724 Change Dial Numbers MCP MCP2 STN Dial Number Set the extension number as 2400 2599 STNG Dial Number Set the extension group number as 5200 5279 TRKG Dial Number Set 800 FEAT Dial Number Set LCR as 9 gt To make trunk line call dial 9 and the target telephone number NTWK LCR Dial No IDX 01 20 IDX 02 21 IDX 03 22 IDX 04 23 IDX 05 26 IDX 06 50 IDX 07 51 IDX 08 53 SAMSUNG Electronics Co Ltd Page 12 21 CHAPTER 12 Networking Description and Programming Procedure OfficeServ 500 Installation Guide Ed 01 Program 824 Convert Auto Route Selection Expansion Dial Index Phone No Converted No SZ Max MB 01 20 09120 4 7 N 02 21 09221 4 7 N 03 22 09222 4 7 N 04 23 09223 4 7 N 05 26
12. CAUTION Indicate a potentially hazardous situation which if not avoided may result in minor or CAUTION moderate injury It may also be used to alert against unsafe practices NOTE Indicates additional information as a reference Reference Page Il OfficeServ 500 General Description Guide Introduces an overview of the Samsung OfficeServ 500 including system structure and hardware features and facilities and specifications OfficeServ 500 Programming Guide This guide is a programming MMC description for OfficeServ 500 system users OfficeServ 500 Service Manual Introduces circuit configuration of each section in OfficeServ 500 system main functions parts list troubleshooting and disassembly diagram of main device DS 5012L Digital Phone User s Manual This is a user s manual for the Large LCD Digital Phone DS 5012L that can be used by connecting to the OfficeServ 500 system SAMSUNG Electronics Co Ltd Guide Title Ed 00 Introduction ITP 5012L IP Phone User s Manual This is a user s manual for the Large LCD IP Phone that can be used by connecting to the OfficeServ 500 system DS 5038D 5021D 5014D Digital Phone User Guide This is a user s manual for the 2 Line LCD Digital Phone DS 5038D DS 5012D DS 5014D that can be used by connecting to the OfficeServ 500 system ITP 5021D 5014D IP Phone User Guide This is a user s manual for the 2 Line LCD IP Phone ITP 5021D ITP 5014D that ca
13. SOT 5102 5103 3104 TAN PSU B PSUGO Slott Slot2 Slot3 Slot4 Slot Slot Slot7 Slot Jaapct WE PSU B PSUBO Stott Slot2 Slot3 Son slots Slot Slot7 ag Amprt ME Figure 3 17 Cabinet Slot Numbers SAMSUNG Electronics Co Ltd Page 3 23 CHAPTER 3 Installing Printed Circuit Cards OfficeServ 500 Installation Guide Ed 01 SIO PORT when MCP MCP2 Mounted MCP Default RS 232C PORT SIO1 SIO2 Option RS 232C PORT SIO3 SIO4 MCP2 Default RS 232C PORT SIO2 SIO3 Debug SIO1 16 TRKB CARD This card has no selectable options Insert as many TRK B cards as are needed into any universal slots see Figure 3 2 Push firmly in the middle of both card ejectors on each card to ensure that it is fully inserted into the back plane connector I TRK B 8TRK 6TRK BRIN l L Figure 3 18A Interface Cards The hardware appearance of Line Card e g E amp M DLI 16DLI SLI 8SLI 16SLI 8MWSLI 16MWSLI is identical with the above TRK B card Page 3 24 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 3 Installing Printed Circuit Cards 17 6TRK CARD This card has no selectable options Insert as many 6TRK cards as
14. System C run ine Group None Voir Network group None Sv Group no none AtendaniNe None System B rune ine Group None Su Group no None AtendantNo None System D Station No 2600 2699 trunk line Group None PRI Newark group None Sv Group No None AtendantNo None Figure 12 2 Networking Programming Example for Each Point SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 2 5 1 System A Programming CHAPTER 12 Networking Description and Programming Procedure Program 820 Set System Link Number MCP MCP2 Index Link ID Signal G W SELF 091 168 219 100 100 SYS01 092 168 219 110 110 SYS02 093 SYS03 094 168 219 120 120 Program 821 Set Networking trunk line gt Unnecessary because it is connected only to PRI Set TEPRI card connected with System B or C as Q Signaling Program 724 Change Dial Numbers MCP MCP2 STN Dial Number STNG Dial Number TRKG Dial Number FEAT Dial Number NTWK LCR Dial No Set the extension number as 2000 2099 Set the extension group number as 5000 5079 Set 800 801 802 and 803 Set LCR as 93 To make trunk line call dial 9 and the target telephone number 211s converted to 2100 2199 call number IDX 01 in 824 IDX 02 IDX 03 IDX 04 IDX 05 IDX 06 IDX 07 IDX 08 IDX 09 22 23 24 25 26 51 52 53 Program 824 Convert Auto Route Selection Expansion Dial
15. Prepare all of the OfficeServ 500 cabinets by removing the side and front covers of the cabinets prior to installation to avoid damaging the covers and to allow access to the interior In addition the top covers and the bottom panels from the cabinets must be removed 1 Remove the four screws holding each side cover support bracket and remove the brackets from both sides of the cabinet see Figure 2 4 These brackets are not required for rack mounting Bracket Screws Bracket Ground Bar Bracket Screws Ss Bracket Figure 2 3 Side Cover Mounting Brackets 2 Removethe ground bar from the left side of the cabinet see Figure 2 4 3 Remove the breakout panels from the base of all the cabinets to allow cable access SAMSUNG Electronics Co Ltd Page 2 7 OfficeServ 500 Installation Guide Ed 01 CHAPTER 2 Installing Single Multiple Cabinet Configurations 4 Install the cabinets in the rack leaving approximately 50mm of space between each cabinet to allow cable access and secure each cabinet with eight screws in the mounting flange holes see Figure 2 5 dub deb dea dea E SIO4 LAN 5102 5103 Slot6 Slot7 Slot8 Slotg SCP SIO1 PSU B PSUGO Slotti Slot2 Slot3 Slot4 Slot5 al LEA Fri o ai
16. To install the IPM board remove the two 2 screws holding the MCP protective casing together see Figure 3 6 and separate the two halves of the case Place the IPM board face down over the three connectors taking care to properly line them up and press gently on the back of the board to seat it The MCP case can now be reassembled if all required daughter boards have been installed Do not forget to turn on the memory backup switch on the IPM board before installing it on the MCP See Figures 3 1 and 3 7 Not mounted on the MCP2 card En E DU LA I SS 145 145 141 mem DODODO f aT Ba SC y R75 RAI RAD CTO R37 R35 ROT Weg ua 6 7 wa TTT Memory 7 AA go Backup 03 vn AAO Figure 3 8 IPM Board SAMSUNG Electronics Co Ltd Page 3 15 9 CHAPTER 3 Installing Printed Circuit Cards OfficeServ 500 Installation Guide Ed 01 LAN BOARD This board has a switch
17. LCRT 0001 00 12 4 gt Enter 12 digits at the minimum for the international call 0002 01 10 4 Enter 10 digits at the minimum for the mobile call 0003 02 9 4 Enter 9 digits at the minimum for the long distance call Seoul 0004 03 10 4 gt The long distance call Except Seoul 0005 04 10 4 0006 05 10 4 0007 06 10 4 0008 07 10 4 gt 070 call 0009 08 10 4 gt 080 call 0010 092 7 1 gt The station group call of the system B 0011 093 7 2 gt The station group call of the system C 0012 094 7 3 gt The station group call of the system D 0013 1 3 4 gt Special call 0014 2 7 4 gt Enter 7 digits at the minimum for the local call Page 12 16 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 12 Networking Description and Programming Procedure 0015 3 7 4 0016 4 7 4 SAMSUNG Electronics Co Ltd Page 12 17 CHAPTER 12 Networking Description and Programming Procedure OfficeServ 500 Installation Guide Ed 01 Index Digit Length LCRT 0017 5 7 4 0018 6 7 4 0019 7 7 4 0020 8 7 4 0021 9 7 4 Program 712 Enter the Route Table for Auto Route Selection MCP MCP2 Table Time Class Route Modify 01 1 1 803 Sends the call through the 803 group at first 2 801 Sends the call through the 801 group when the 803 group is all used 02 1 1 802 03 1 1 803 04 1 1 800 Program 601 Station Group MCP MCP2 5000 Set
18. OFF indicates that power is OFF ON indicates that the LCP is booting Flicker indicates normal operation S1 S9 Card Status OFF indicates that the card is idle or not installed ON indicates one or more circuits busy Flicker indicates the card has a fault or is inserted in the wrong slots e g TEPRI PRI BRI card must be inserted in the slot 1 or 2 or 3 otherwise LED flickers Page 3 12 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 3 Installing Printed Circuit Cards 6 LCP2 CARD When the system is configured in two or more cabinets the LCP2 card controls the operation of the expansion cabinet and exchanges messages with the MCP2 card through a high speed data link The LCP2 card is mounted on the MCP LCP slot of the OfficeServ 500 L expansion cabinet When the system is configured in one basic cabinet and two expansion cabinets the LCP2 card shall be mounted on the MCP LCP slots of each expansion cabinet The internal DRAM memory of the LCP card is 2 MB while the internal DRAM memory of the LCP2 card is 4 MB Only the internal memory differs between the LCP and LCP2 card Therefore the LCP2 card shall be used for features such as LCD Phone IP Phone and Wireless LAN which require much memories The use configuration of Daughter boards within the card is identical to that of the LCP card SAMSUNG Electronics Co Ltd Page 3 13 CHAPTER 3 Installing Printed Circuit Cards OfficeSe
19. The items below shall be set before using additional features 1 Page 12 10 Display Name and Number of Counter Station Name Identification The options below shall be set to identify the name and number of the other party when calling stations on different systems Sets the CONP level of Program 823 The name and number is sent to the other station according to the CONP level 0 Name and number is not sent 1 Sends name and number when call from another system is being connected dial tone or is connected 2 Sends name and number when the receiving station is busy 3 Sends name and number when the call is being connected is connected or when the receiving station is busy This option is recommended since the information is always sent unless the dialled number is a wrong number SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 12 Networking Description and Programming Procedure 2 3 4 In Q SIG the name and number is sent to the recipient according to the below options of Program 823 The default value is recommended since there are cases when the name and number is always sent to the recipient according to the CONP level not according to these options because the OfficeServ 500 networking was supposed for connections between iDCS systems Default value is set to always send the name and number Calling Line Identification Presentation CLIP Y Calling Line Identificati
20. of the three cabinets prior to installation to avoid damaging the covers and to allow access to the interior Remove the top cover from the bottom and center cabinets and the base and rear panels from the upper two cabinets 2 Place the center cabinet on top of the main base cabinet ensuring that the center cabinet locating bumps are snug in the lower cabinet locating dimples Install the two provided screws in the dimples in the front lower panel of the center VOLTAGE SETTING cabinet and the two provided screws in the dimples in the rear lower panel of the center cabinet Replace the rear panel on the center cabinet FUSES 3 Place the top cabinet on top of the center cabinet ensuring that the top cabinet locating bumps are snug in the center cabinet locating dimples Install the two provided screws in the dimples in the lower panel of the top cabinet and the two provided screws in the dimples in the rear lower panel of the top cabinet Replace the rear panel on the top cabinet Figure 2 3 Setting Voltage on PSU B SAMSUNG Electronics Co Ltd Page 2 5 CHAPTER 2 Installing Single Multiple Cabinet Configurations OfficeServ 500 Installation Guide Ed 01 Connect the AC power cord and the AC power cable between cabinets but do not turn ON to the system prior to installing any cards refer to Section Grounding When a power supply is installed verify that the power switch is in the proper voltage setting 1
21. 09426 4 7 N 06 50 09150 4 7 N 07 51 09251 4 7 N 08 53 09453 4 7 N Program 714 Enter the Conversion Table of Dialling a Station Directly MCP MCP2 Dark 002 DEE B 0 Program 603 trunk line Group MCP MCP2 800 Set PRI of TEPRI connected with System A through Networking Program 710 Enter a Digit for Auto Route Selection MCP MCP2 Index Digit Length LCRT 0001 00 12 2 International call Sends to the system A 0002 01 10 2 Mobile call Sends to the system A 0003 02 9 2 Long distance call Sends to the system A 0004 03 10 2 gt Local call Sends to the system A 0005 04 10 2 0006 05 10 2 0007 06 10 2 0008 07 10 2 gt 070 call Sends to the system A 0009 08 10 2 gt 080 call Sends to the system A 0010 091 7 1 gt The station call of the system A Sends to the system A 0011 092 7 1 gt The station call of the system B Sends to the system A 0012 094 7 1 gt The station call of the system D Sends to the system A Page 12 22 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 12 Networking Description and Programming Procedure Index Digit Length LCRT gt Special call Sends to the system A wo 0013 0014 0015 0016 0017 0018 0019 0020 0021 gt Local call Sends to the system A o jo d o R N NIN ONIN IN IN ONIN NIM MIM ID IR ND IN Program 71
22. 1 bottom but it should be removed from the other shelves shelf 2 and shelf 3 CAUTION SAMSUNG Electronics Co Ltd Page 2 3 A Page 2 4 CHAPTER 2 Installing Single Multiple Cabinet Configurations OfficeServ 500 Installation Guide Ed 01 TWO CABINET INSTALLATION FLOOR MOUNT Check to see that each OfficeServ 500 cabinet carton includes the following items OfficeServ 500 Cabinet Top cover Left and right side covers Front cover Cabinet leg mounting kit AC power and Battery Cables Check to see that all additional OfficeServ 500 hardware and software is available for installation at this time 1 Floor mounting equipment foot or castors Cards required to make the OfficeServ 500 system functional E g power supply central processor station and trunk cards Mount the legs or castors to one of the OfficeServ 500 cabinets as the floor mounted base cabinet Prepare both of the OfficeServ 500 Cabinets by removing the side and front covers of both cabinets prior to installation to avoid damaging the covers and to allow access to the interior Remove the top cover from the bottom cabinet and the base and rear panels from the upper cabinet Place the upper cabinet on top of the main lower cabinet ensuring that the upper cabinet locating bumps are snug in the lower cabinet locating dimples Install the two provided screws in the dimples in the front lower panel of the upper cabinet and the two provided screws in
23. 52 09352 4 7 N Program 714 Enter the Conversion Table of Dialling a Station Directly MCP MCP2 001 Sex E B 0 002 SC B 0 Program 603 trunk line Group MCP MCP2 803 Set VoIP Networking Signaling trunk line Page 12 24 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 12 Networking Description and Programming Procedure Program 710 Enter a Digit for Auto Route Selection MCP MCP2 Index Digit Length LCRT 0001 00 12 2 gt International call Sends to the system A 0002 01 10 2 Mobile call Sends to the system A 0003 02 9 2 gt Long distance call Sends to the system A 0004 03 10 2 gt Local call Sends to the system A 0005 04 10 2 0006 05 10 2 0007 06 10 2 0008 07 10 2 gt 070 call sends to the system A 0009 08 10 2 gt 080 call Sends to the system A 0010 091 7 1 gt The station call of the system A 0011 092 7 1 gt The station call of the system B 0012 093 7 1 gt The station call of the system C Sends to the system A 0013 1 3 2 gt Special call Sends to the system A 0014 2 7 2 gt Local call Sends to the system A 0015 3 7 2 0016 4 7 2 0017 5 7 2 0018 6 7 2 0019 7 7 2 0020 8 7 2 0021 9 7 2 Program 712 Enter the Route Table for Auto Route Selection MCP MCP2 02 1 1 803 001 gt Sends to the system A for outgoing through trunk line Program 713 En
24. Attendant Group 5049 Set SVMi Group Program 825 ADD Number To Name Yes Use Remote Voice Mail No Remote CID Number Yes 2 5 2 System B Programming Program 820 Set System Link Number MCP MCP2 Index Link ID Signal G W SELF 092 168 219 110 110 SYS01 091 168 219 100 100 SYS02 093 SYS03 094 168 219 120 120 Program 821 Set Networking trunk line Set TEPRI card connected with System A as Q Signaling Page 12 18 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 12 Networking Description and Programming Procedure Program 724 Change Dial Numbers MCP MCP2 STN Dial Number Set the extension number as 2100 2399 STNG Dial Number Set the extension group number as 5100 5179 TRKG Dial Number Set 800 and 803 FEAT Dial Number Set LCR as 93 To make trunk line call dial 9 and the target telephone number NTWK LCR Dial No IDX 01 20 IDX 02 24 IDX 03 25 IDX 04 26 IDX 05 50 IDX 06 52 IDX 07 53 Program 824 Convert Auto Route Selection Expansion Dial Index Phone No Converted No SZ Max MB 01 20 09120 4 7 N 02 24 09324 4 7 N 03 25 09325 4 7 N 04 26 09426 4 7 N 05 50 09150 4 7 N 06 52 09352 4 7 N 07 53 09453 4 7 N Program 714 Enter the Conversion Table of Dialling a Station Directly MCP MCP2 001 get B 0 002 ger B 0 Program 310 Set Auto Route Selection Class Set LCR class of all stations as 2 Program 603 trunk
25. Cl sw MFM i RCM PS P11 OI swz n AH P8 Elo O Figure 3 5 LCP Card O SAMSUNG Electronics Co Ltd Page 3 11 CHAPTER 3 Installing Printed Circuit Cards OfficeServ 500 Installation Guide Ed 01 Push firmly at the top and bottom of the card to ensure that it is fully inserted into the back plane connector Connect the OfficeServ 500 Inter Processor Connection cable CIC to the front of the LCP Connect the opposite end of the CIC to the connector on the front of the MCP Connect the second CIC in a similar manner between LCP cards The CIC is supplied with the LCP ei Do not insert this card with system power ON NOTE To prevent accidental damage to the LCP card the MCP LCP connector on the back plane is positioned to mate only with the MCP or LCP card Other interface cards will not mate with this connector and the MCP or LCP card will not mate with any other connector There are twelve 12 LED indicators on the front of the LCP card The uses are as follows Tx LCP HDLC Tx Transmit Status OFF indicates that there is no link from the LCP card ON indicates that the link from the LCP card is being set up Flicker indicates a message has been transmitted Rx LCP HDLC Rx Receive Status OFF indicates that there is no link from the LCP card ON indicates that the link from the LCP card is being set up Flicker indicates a message has been received LCP LCP Processor Status
26. Ed 01 CHAPTER 7 Connecting Optional Equipment The PCMMC port shall be assigned as shown below at MMC804 System Configuration Port number at MMC804 Connection port on IOM board MCP card used LAN unused Select from 1 2 SI101 SIO2 MCP card used LAN used Select from 1 4 SIO1 SIO4 MCP2 card used Select from 2 3 SIO2 SIO3 When connecting a PC to the IOM card serial ports an approved Data Isolation Unit must be installed CAUTION 7 VOICE MAIL AUTO ATTENDANT System operation provides special programming and hardware for use with a customer provided voice mail auto attendant system The OfficeServ 500 supports connections to third party supplied voicemail AA systems via SLI ports Refer to Chapter 6 for SLI connection details For more information on programming these ports See the Programming Guide MMCs 207 601 and 726 SAMSUNG Electronics Co Ltd Page 7 7 CHAPTER 7 Connecting Optional Equipment OfficeServ 500 Installation Guide Ed 01 8 Page 7 8 CONNECTING SYSTEM BACKUP BATTERIES TO THE OfficeServ 500 POWER SUPPLY The OfficeServ 500 power supplies PSU B and PSU60 contain a monitoring circuit to switch the system to customer provided 48VDC batteries when AC power is interrupted Calls in progress are not disconnected The power supply circuitry monitors and recharges batteries as needed Connect four 12V batteries or eight 6V batteries in series Any NICAD or lead acid car or motorcycle t
27. Installing Single Multiple Cabinet Configurations When a Power supply is installed verify that the power switch is in the proper voltage setting 110V or 220V required see Figure 2 3 Wall mount a single cabinet configuration only Multiple cabinet configurations MUST be floor mounted with legs or locking castors or mounted in a 19 inch rack To floor mount locate the optional legs or locking castors Remove side and front covers of the cabinets prior to installation to avoid damaging the covers and to allow access to the interior Place the cabinet on a secure surface floor or workbench with the front of the cabinet card slots facing up With the enclosed machine screws mount the legs or castors on each corner of the first cabinet see Figure 2 2 Place cabinet upright in the desired location MOUNTING SCREWS Figure 2 2 Attaching legs to main cabinet The final step in installing the cabinet is installing the required PSU B MCP MCP2 OfficeServ 500 Main Control Processor with SmartMedia card station and or trunk cards and MDF cables See sections Power Connection MDF Cabling Chapter 3 and Chapter 9 of this guide to determine the basic required configuration and to make the system operational As the system is for Technician access only when replacing the front cover the screws must be tightened using a screw driver The metal bottom cover see the Figure 2 2 should be installed to the shelf
28. Location 3 36 AAUCD Gad Enia renier ins 3 37 SVMis16 Cad ne eee RE ae 3 39 BW Gard ae ato 3 42 ITMS Cardiaco ila e les los int Dea sue eege ee e 3 44 LED Display of the MGI3 Card 3 45 MGI 1 2 Gard i ln did 3 47 V DIAL Card rise ne de Roadie oases ts a nn nt etes Mit 3 50 SAMSUNG Electronics Co Ltd Page XIII Table Of Contents Figure 4 1 Figure 5 1 Figure 5 2 Figure 5 3 Figure 5 4 Figure 5 5 Figure 5 6A Figure 5 6B Figure 5 7A Figure 5 7B Figure 5 8 Figure 5 9 Figure 6 1 Figure 6 2 Figure 6 3 Figure 6 4 Figure 6 5 Figure 7 1 Figure 7 2 Figure 7 3 Figure 7 4 Figure 7 5 Figure 7 6 Figure 7 7 Figure 7 8 Figure 7 9 Figure 10 1 Figure 12 1 Figure 12 2 LIST OF TABLES Table 3 1 Table 6 1 Table 6 2 Page XIV OfficeServ 500 Installation Guide Ed 01 Setting Voltage on PDGULDB iii 4 5 TRIER Gene e 5 2 MDF Connections Loop Start Line to 6 or 8Trunk Card 5 3 MDF Connections E M Tie Line to E amp M Tie Line and E amp M Card 5 4 MDF Connections Off Premise Extension from SLI Card 5 5 MDF Connections E1 PRI Circuit to TEPRI Card 5 6 MDF Trunk Connections 5 7 MDF Station Connections i 5 8 MDF Gonnections RJ 45 oct lar 5 10 Cables Between DBS and 8BSI RJ 45 to RI 45 eee ceeeeeeeeeeeetteeeneees 5 11 Wireless LAN System Configuration Diagram i 5 12 WBS24 8WLI Wiring Diagram
29. S1 for memory back up and installs in position LOC3 see Figure 3 1 of the MCP card when the system has more than one cabinet installed or in position LOC2 if the system is going to require a MISC board in a single cabinet system with M version software The LAN board is required to expand the system memory to provide SIO ports 3 and 4 and a 10BASE T LAN interface processor To install the LAN board remove the two 2 screws holding the MCP protective casing together see Figure 3 6 and separate the two halves of the case Place the LAN board face down over the three connectors taking care to properly line them up and press gently on the back of the board to seat it The MCP case can now be reassembled if all required daughter boards have been installed Do not forget to turn on the memory backup switch on the LAN board before installing it on the MCP see Figures 3 1 and 3 8 OTE Not mounted on the MCP2 card Figure 3 9 LAN Board Page 3 16 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 3 Installing Printed Circuit Cards 10 MISC BOARD This bo
30. SLT TIP SLT TIP 4 SLT RING SLT RING SLT RING 30 4 SLT TIP SLT TIP SLT TIP 5 SLT RING SLT RING SLT RING 31 6 32 5 SLT TIP SLT TIP 7 SLT RING SLT RING 33 6 SLT TIP SLT TIP 8 SLT RING SLT RING 34 9 35 7 SLT TIP SLT TIP 10 SLT RING SLT RING 36 8 SLT TIP SLT TIP 11 SLT RING SLT RING 37 12 38 9 SLT TIP 13 SLT RING 39 10 SLT TIP 14 SLT RING 40 15 41 11 SLT TIP 16 SLT RING 42 12 SLT TIP 17 SLT RING 43 18 44 13 SLT TIP 19 SLT RING 45 14 SLT TIP 20 SLT RING 46 21 47 15 SLT TIP 22 SLT RING 48 16 SLT TIP 23 SLT RING Page 6 6 NO OTHER CONNECTIONS Figure 6 3 MDF Connections Single Line Telephone to SLI Card SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 6 Connecting Station Equipment 6 DOOR PHONE AND DOOR LOCK RELEASE Using one pair twisted 0 50 mm jumper wire cross connect each DPIM to the DLI port see Figure 6 1 or plug into the KDB DLI of your choice Next connect the DPIM to the door phone using 24 AWG or 26 AWG twisted pair wire To reduce the risk of fire use only the supplied line cord or other approved line cord WARNING When a customer provided electric door release is installed cross connect the corresponding door release contacts on the DPIM to the door lock mechanism Use MMC 501 to program the duration of the contact closure as required The door release contacts on the DPIM are to be used for
31. TIP DLI TIP 8 DLI RING DLI RING 34 9 35 7 DLI TIP DLI TIP 10 DLI RING DLI RING 36 8 DLI TIP DLI TIP 11 DLI RING DU RING www 37 12 38 9 DLI TIP eu 13 DLI RING e af 39 10 DLI TIP p 14 DLI RING ES Ee 40 15 DIGITAL PHONE 41 11 DLI TIP 16 DLI RING 42 12 DLI TIP LE DURING CONNECT TO ANY CIRCUIT e ON ANY DLI CARD 44 13 DLI TIP 19 DLI RING 45 14 DLI TIP 20 DLI RING 46 21 47 15 DLI TIP 22 DLI RING 48 16 DLI TIP 23 DLI RING NO OTHER CONNECTIONS Figure 6 1 MDF Connections Digital phone to DLI Card Page 6 2 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 6 Connecting Station Equipment 3 OfficeServ 500 ADD ON MODULES AOM The OfficeServ 500 system supports the iDCS 64 button AOM and the DCS 48 button AOM The system capacities are detailed in the table below System DCS 48 Button AOM iDCS 64 Button AOM OfficeServ 500 M No limitation AOM can be connected No limitation AOM can be connected as many as DLI port as many as DLI port OfficeServ 500 L Max of 32 Max of 8 Using one pair of twisted 0 50 mm jumper wire cross connect each AOM to the DLI port See Figure 6 1 or plug into the KDB DLI of your choice Assign the AOM to a station in MMC 209 AOMs can be assigned to any phone To reduce the risk of fire use only the supplied line cord or other approved line cord WARNING SAMSUNG Electronics Co Ltd Page 6 3 CHAPTER 6
32. This equipment is to be installed only in Restricted Access Areas Dedicated Equipment Rooms Equipment Closets or the like Allow at least 254mm clearance on both sides and 254mm clearance on top of the system to ensure proper ventilation and access to the interior of the cabinet Do not install in close proximity to a fire sprinkler head or to other sources of water e Space consideration must be made to allow floor or wall mounting Do not wall mount a multiple cabinet system Meeting these requirements will help to ensure proper performance and greater life expectancy of the system SAMSUNG Electronics Co Ltd CHAPTER 2 Installing Single Multiple Cabinet Configurations 1 UNPACKING AND INSPECTION The OfficeServ 500 can be configured as a single cabinet a dual cabinet system or a three cabinet system An OfficeServ 500 single cabinet system may be wall floor or rack mounted while multiple cabinets systems may only be floor or rack mounted Do not attempt to wall mount any system other than a single cabinet system All the OfficeServ 500 cabinets are identical when shipped from SAMSUNG After unpacking the cabinet s inspect for signs of physical damage If any damage is detected do not attempt installation Contact SAMSUNG Technical Support Department Check to see that each OfficeServ 500 Cabinet carton includes the following items e OfficeServ 500 Cabinet Top cover Left and right side covers e Fron
33. Using the screws provided in the Ringer card to the stand offs see Figure 2 8 Ringer Connector e 200000000000 Ringer Card Ringer Cable Figure 2 7 Ringer Card Location Page 2 14 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 2 Installing Single Multiple Cabinet Configurations Insert the Ringer connection cable into the Ringer socket on the motherboard as shown in Figure 2 8 Replace the back cover of the cabinet In the front of the cabinet locate the external ringer link as shown in Figure 2 9 and ensure that it is shorting the two right hand pins as detailed below Ringer o of Oo INT Ze External Se Figure 2 8 External Ringer Link ion Only For Australia and Italy SAMSUNG Electronics Co Ltd Page 2 15 CHAPTER 2 Installing Single Multiple Cabinet Configurations OfficeServ 500 Installation Guide Ed 01 10 Page 2 16 MDF CABLING All connections to the OfficeServ 500 system are made by way of a customer provided main distribution frame MDF Each interface card with the exception of the TEPRI ITM3 cards is connected to the MDF using a 25 pair female amphenol type cable These cables can be routed into the OfficeServ 500 cabinet s from below or on the right side of the cabinet Label each cable to correspon
34. are needed into any universal slots Push firmly in the middle of both card ejectors on each card to ensure that it is fully inserted into the back plane connector 18 8TRK CARD This card has no selectable options Insert as many 8TRK cards as are needed into any universal slot Push firmly in the middle of both card ejectors on each card to ensure that it is fully inserted into the back plane connector SAMSUNG Electronics Co Ltd Page 3 25 CHAPTER 3 Installing Printed Circuit Cards OfficeServ 500 Installation Guide Ed 01 19 PRICARD This PRI card must be inserted in slots 1 2 or 3 of any cabinets The PRI supports ISDN PRI service Push firmly in the middle of both card ejectors on each card to ensure that it is fully inserted into the back plane connector PA Do not insert this card with system power ON DT y Figure 3 18B PRI Card Page 3 26 O SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 3 Installing Printed Circuit Cards 20 8BSI CARD The 8BSI Base Station Interface card must be inserted in slots 1 2 or 3 of same cabinet If multiple 8BSI cards are installed in an OfficeServ 500 L system then the 8BSI cards must be installed in the same cabinet Push firmly in the middle of the
35. industry standard message waiting lamps on single line phones The message waiting power supplied to the single line station in the iDCS is 90 to 100 VDC The 8MWSLI has no DTMF receivers it will share the system wide DSP resources for DTMF decoding When the 8MWSLI cards are highly utilized with congested traffic the ratio of DTMF receiver will be decreased Therefore the MFM boards or daughter board should be added to a processor card to relieve the bottleneck daughter board should be added to a processor card to relieve the bottleneck e VO It 1 If a cabinet is equipped with a single power supply unit PSU B a maximum of 56 station devices may be connected to that cabinet However if the cabinet is equipped with two power supply units a maximum of 120 station devices may be connected to that cabinet See the configuration section of the General Description Guide for more details 2 Do not connect devices with a total REN greater than 5 0 to this card Except for Australia Australia use an external ringer 3 Ringer Frequency External Ringer 20 Hz 80 Vrms SINUSOIDAL WAVE For Australia and Italy Internal Ringer 25 Hz 80 V RECTANGULAR WAVE For the other countries in Europe 4 This card does not contain OPX over voltage protection circuitry 5 The message waiting circuitry only illuminates the message lamp when the station is idle Therefore an 8SLI card and the 8MWSLI card follow the same configuration rul
36. low voltage relay control only The contacts are rated at 24 VDC 1 amp When connecting a customer supplied electric door release mechanism to the DPIM an approved Line Isolation unit must be installed Do not attempt to connect Zeen commercial AC power to the DPIM contacts DOOR PHONE INTERFACE MODULE DP1M NEE Gr Wii ypu W DC LIU ONE PAIR dy Qi PORT DOOR PHONE 10 CUSTOMER PROVIDED DOOR LOCK RELEASE Figure 6 4 MDF Connections Door Phone and DPIM to DLI Card SAMSUNG Electronics Co Ltd Page 6 7 CHAPTER 6 Connecting Station Equipment OfficeServ 500 Installation Guide Ed 01 7 7 1 7 2 Page 6 8 DECT STATION DECT Station Overview OfficeServ 500 system provides DECT cordless communications in a single office or throughout a large commercial or industrial complex To implement this service you need 8BSI card DBS card and DECT handsets Users of this service meet improved overall efficiency since staff can be reached or make calls wherever they are OfficeServ 500 M system supports one 8BSI card and the OfficeServ 500 L supports a maximum of three 8BSI cards In case of OfficeServ 500 L the 8BSI cards must be installed in the same cabinet and installed in slots 1 2 and or 3 because the 8BSI card supports a maximum of 32 B channels Using 2 pair twisted 0 64mm cable to a length of 600 metres or 0 40mm cable to a length of 400 metres cross connect each base s
37. module are connected to this card There are multiple connectors at the front of the card The use of these connectors is optional and does not need to be connected to run SVMi 16 Serial Interface Serial interface can be used for connecting modem or PC and supports management based on local or remote PC This connector is called SIO SAMSUNG Electronics Co Ltd Page 3 39 CHAPTER 3 Installing Printed Circuit Cards OfficeServ 500 Installation Guide Ed 01 Reset Button The red button marked RST is the reset button After mounting the SVMi 16 card and turning the telephone system power switch on this button must be pressed to initialize SVMi 16 Pressing this button will restart the SVMi 16 system and the calls being processed will be disconnected When the Reset button is pressed during operation all calls are disconnected and SVMi 16 restarts immediately This button shall be used as instructed If this button is pressed when SVMi 16 is executing disk I O data may be loss or files can be damaged 1 Do not insert this card with system power ON a 2 Be careful when you press this button while SVMI 16 is actually processing a call Data may be loss and files can be damaged Page 3 40 VPM Connector VPM connector is the main connector required for installing two VPMs In a right angle to the connector at the edge of the card behind the consecutive ports there is a shorter connector This connector is used t
38. on the back of the board to seat it The MCP MCP2 SCP SCP2 case can now be reassembled if all required daughter boards have been installed Figure 3 12 SCM Board Only one SCM board can be installed per system SCM card cannot be installed with a MFM card on the same processor card SAMSUNG Electronics Co Ltd Page 3 19 CHAPTER 3 Installing Printed Circuit Cards OfficeServ 500 Installation Guide Ed 01 12 MFM BOARD This board has no selectable options and installs in any available position of the MCP MCP2 card when the system has one cabinet installed see Figure 3 1 If the system has more than one cabinet the MFM board must be installed in position LOC3 of the MCP MCP2 card any available position of the SCP SCP2 card see Figure 3 3 or any available position of the LCP LCP2 cards Up to 3 MFM board can be installed in a system one on the MCP MCP2 or SCP SCP2 and one on each LCP LCP2 The MFM board is used to provide an additional 12 DSP circuits for DTMF and tone detection To install the MFM board remove the two 2 screws holding the MCP MCP2 or LCP LCP2 protective casing together see Figure 3 6 or remove the 4 screws holding the SCP SCP2 case together see Figure 3 10 and separate the two halves of the case Place the MFM board face down over the two connectors taking care to properly line them up and press gently on the back of the board to seat it The MCP MCP2 LCP LCP2 SCP SCP2 case can now be reassemb
39. the OfficeServ 500 system and 8WLI can interlock up to 8 WBS24s And since two DASL line is connected to one WBS24 2x 2B 1D 4 voice channel simultaneous call is supported 48 V DC power is supplied from the system through cable and serves as the path for transmitting and receiving voice and signaling data between 8WLI and WBS24 Therefore one 8WLI board supports up to 32 voice channels One board shall be mounted per system and shall be mounted on one of the S1 S2 or S3 slot regardless of the cabinet Champ connector RS 232C connector Figure 3 23 8WLI Card Page 3 42 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 3 Installing Printed Circuit Cards 35 IP TELEPHONY MODULE ITM3 The OfficeServ 500 system supports the VoIP feature using the ITM3 card The ITM3 card is equipped with 8 VoIP ports that can be increased to 16 by the addition of the ITM3D daughter card Two 40 pin connectors on the ITM3 card support the connection of the ITM3D daughter card Refer to the diagram below The ITM3 card is installed in any universal card slot of any cabinet Insert the ITM3 card into the card guide and slide the card until it makes contact with the back plane connector Press firmly on the top and bottom of the card to ensure it is fully inserted into the back plane connector The ITM3 card takes approximately 3 minutes to initialize and during this time the relevant slot LED on the MCP SCP LCP card wil
40. the dimples in the rear lower panel of the upper cabinet Replace the rear panel on the upper cabinet Connect the AC power cord and the AC power cable between cabinets but do not turn ON to the system prior to installing any cards refer to Section Grounding When a power supply is installed verify that the power switch is in the proper voltage setting 110V or 220V required position see Figure 2 3 See sections Power Connection MDF Cabling Chapter 3 and Chapter 4 of this guide to determine the basic required configuration and to make the system operational SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 2 Installing Single Multiple Cabinet Configurations 4 THREE CABINET INSTALLATION FLOOR MOUNT Check to see that each OfficeServ 500 cabinet carton includes the following items e OfficeServ 500 Cabinet e Top cover Left and right side covers e Front cover e Cabinet leg mounting kit AC power and Battery Cables Check to see that all additional OfficeServ 500 hardware and software is available for installation at this time e Floor mounting equipment foot or castors Cards required to make the OfficeServ 500 system functional E g power supply central processor station and trunk cards 1 Mount the legs or castors to one of the OfficeServ 500 cabinets as the floor mounted base cabinet Prepare all of the OfficeServ 500 cabinets by removing the side and front covers
41. 0 M2 3 5 Rx2 TIP 31 Rx2 RING S 6 Tx3 TIP 32 Tx3 RING R 7 E3 33 TELCO PROVIDED M3 8 NETWORK MDF Rx3 TIP A 34 Rx3 RING 9 Tx4 TIP e 35 Tx4 RING 10 E4 36 M4 S 11 Rx4 TIP 37 Rx4 RING 12 NO OTHER CONNECTIONS CONNECT TO 4 Wire E amp M CIRCUIT Figure 5 3 MDF Connections E amp M Tie Line to E amp M Tie Line and E amp M Card Page 5 4 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 5 Connecting Trunk Line Circuits 4 OFF PREMISE EXTENSIONS OPX Using one pair twisted 0 50mm jumper wire cross connect iDCS single line extensions to telephone company OPX circuits see Figure 5 4 Circuits on the SLI card are specifically designed to meet TELCO requirements for OPX use These circuits are provided with the same over voltage and over current protection as that of trunk line circuits Using single line stations on any other SLI card or a KDB SLI requires the installation of externally mounted protection devices There is no special programming required for OPX use however it is suggested that the OPX ports are set for CO ring in MMC 208 25 PAIR CABLE WITH FEMALE CONNECTOR TO ANY SLI CARD FUNCTION CIRCUIT PIN SLT TIP 26 SLT RING 1 SLT TIP 27 SLT RING 2 28 3 SLT TIP A 29 SLT RING 4 TELCO PROVIDED GER 4 si NETWORK MDF SIT RING y 31 6 NO OTHER CONNECTIONS CONNECT TO ODX TIELINE CIRCUIT F
42. 0 nn Tess bh Oh usas LAN Network HUE 0 DEE Ent Ethernet Digital Phone IP Phone Figure 6 2 IP Telephone connection diagram SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 6 Connecting Station Equipment 5 SINGLE LINE TELEPHONES The OfficeServ 500 system supports a range of Single line telephone interface cards including SLI 8SLI 8MWSLI 16 SLI and 16MWSLI cards Using one pair of twisted 0 50mm jumper wire cross connect each single line telephone to the SLI port see Figure 6 2 of the SLI card type used or plug into the KDB SLI of your choice For convenience the diagram below provides connection details for al SLI card types To reduce the risk of fire use only the supplied line cord or other approved line cord WARNING Single Line Telephones with message waiting lamps must be connected to the 8MWSLI or 16MWSLI card SAMSUNG Electronics Co Ltd Page 6 5 CHAPTER 6 Connecting Station Equipment 25 PAIR CABLE WITH FEMALE CONNECTOR TO SLI CARDS OfficeServ 500 Installation Guide Ed 01 ONE PAIR TWISTED STATION CABLE SINGLE LINE TELEPHONE CONNECT TO ANY CIRCUIT ON ANY SLI CARD PIN CIRCUIT 16DLI 8DLI 4DLI 26 1 SLT TIP SLT TIP SLT TIP 1 SLT RING SLT RING SLT RING 27 2 SLT TIP SLT TIP SLT TIP 2 SLT RING SLT RING SLT RING 28 3 29 3 SLT TIP
43. 0 L system then the 8BSI cards must be installed in the same cabinet Push firmly in the middle of the card to ensure that it is fully inserted into the back plane connector The SAMSUNG OfficeServ 500 system receives it clock information from ISDN services connected so a PRI or BRI card where installed must be installed in a lower slot number e g C1 S1 than the 8BSI card However if ISDN circuits are not installed the 8BSI card would normally be installed in slot 1 of the OfficeServ 500 cabinet The PRI supports ISDN PRI service Push firmly in the middle of both card ejectors on each card to ensure that it is fully inserted into the back plane connector ISDN cards like PRI and BRI use the external clock from the public network So when a SAMSUNG DECT system use PRI or BRI the system must align with the external clock as a slave Also installed 8BSI card uses the same clock as ISDN cards So the SAMSUNG DECT system determined the clock priority according to the card type and the position of slot At first according to the second clock priority and the 8BSI card has the lowest priority In the next priority Do not insert this card with system power ON A maximum of three 8BSI cards can be installed in slots 1 2 or 3 of same cabinet SAMSUNG Electronics Co Ltd Page 5 9 CHAPTER 5 Connecting Trunk Line Circuits OfficeServ 500 Installation Guide Ed 01 25 PAIR CABLE WITH FEMALE CONNECTOR TO ANY BSI CARD
44. 00 fe E a E o e ni A SW Misc2 OMO 5 P Hu l EE pr il s 5 E Figure 3 10 MISC Board SAMSUNG Electronics Co Ltd Page 3 17 CHAPTER 3 Installing Printed Circuit Cards OfficeServ 500 Installation Guide Ed 01 Ejector Tabs Screw Location Figure 3 11 Processor Card Screw Location Page 3 18 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 3 Installing Printed Circuit Cards 11 SCM BOARD This board has selectable options and installs in any available position of the MCP MCP2 card when the system has one cabinet installed see Figure 3 1 If the system has more than one cabinet the SCM board may be installed in any available position of the SCP SCP2 card see Figure 3 3 Only one SCM board can be installed in a system on the MCP MCP2 or SCP SCP2 The SCM board is used to increase the number of available conference circuits by 5 party 18 groups and to add 12 DSP circuits for DTMF and tone detection To install the SCM board remove the two 2 screws holding the MCP MCP2 protective casing together see Figure 3 6 or remove the 4 screws holding the SCP SCP2 case together see Figure 3 10 and separate the two halves of the case Place the SCM board face down over the two connectors taking care to properly line them up and press gently
45. 10V or 220V required see Figure 2 3 position See sections Power Connection 8 MDF Cabling Chapter 3 and Chapter 4 of this guide to determine the basic required configuration and to make the system operation As the system is for Technician access only when replacing the front cover the screws must be tightened using a screw driver 5 ADDING AN OfficeServ 500 EXPANSION CABINET Unplug all sources of AC and DC electricity from the system before attempting this procedure CAUTION 1 Unplug the system AC and or DC power sources 2 Disconnect all cables and wires from the system 3 Proceed as instructed in Section Two Cabinet Installation Section three cabinet installation or Section Rack Mounting a Cabinet 4 Insert the PSU B LCP or LCP2 and additional cards in the added cabinet 5 Connect CIC cable assembly to the LCP or LCP2 6 Connect the AC Battery Cables to the cabinets As the system is for Technician access only when replacing the front cover the screws must be tightened using a screw driver inserted and recognized by the MCP MCP2 processor See System Programming e To activate the new cabinet the additional card slots must have any new cards Section MMC 806 and MMC 724 Page 2 6 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 2 Installing Single Multiple Cabinet Configurations 6 RACK MOUNTING AN OfficeServ 500 CABINET
46. 2 Enter the Route Table for Auto Route Selection MCP MCP2 02 1 1 800 001 gt Sends to the system A for outgoing through trunk line Program 713 Enter a Dial Conversion Table for Auto Route Selection MCP MCP2 001 0919 E gt The first digit 9 added number is sent to the system A for outgoing through trunk line Program 825 ADD Number To Name Yes Use Remote Voice Mail Yes Remote VM Number 5049 2 5 4 System D Programming Program 820 Set System Link Number MCP MCP2 Index Link ID Signal GW SELF 094 168 219 120 120 SYS01 091 168 219 100 100 SYS02 092 168 219 110 110 SYS03 093 SAMSUNG Electronics Co Ltd Page 12 23 CHAPTER 12 Networking Description and Programming Procedure OfficeServ 500 Installation Guide Ed 01 Program 724 Change Dial Numbers MCP MCP2 STN Dial Number Set the extension number as 2600 2699 STNG Dial Number Set the extension group number as 5300 5379 TRKG Dial Number Set 803 FEAT Dial Number Set LCR as 93 To make trunk line call dial 9 and the target telephone number NTWK LCR Dial No IDX 01 20 IDX 02 21 IDX 03 22 IDX 04 23 IDX 05 24 IDX 06 25 IDX 07 50 IDX 08 51 IDX 09 52 Program 824 Convert Auto Route Selection Expansion Dial Index Phone No Converted No SZ Max MB 01 20 09120 4 7 N 02 21 09221 4 7 N 03 22 09222 4 7 N 04 23 09223 4 7 N 05 24 09324 4 7 N 06 25 09325 4 7 N 07 50 09150 4 7 N 08 51 09251 4 7 N 09
47. 32 ON J12 J22 ON J32 J42 ON PORT4 ALL OFF ALL OFF J13 ON J33 ON J13 J31 ON J33 J43 ON Insert as many E amp M cards as are needed into any universal slots Push firmly in the middle of both card ejectors on each card to ensure that it is fully inserted into the back plane connector SAMSUNG Electronics Co Ltd Page 3 27 CHAPTER 3 Installing Printed Circuit Cards OfficeServ 500 Installation Guide Ed 01 22 DLI CARD There are no options to select on this card Insert up to and including nine DLI cards per cabinet as needed into any universal slots see note below Push firmly in the middle of both card ejectors on each card to ensure that it is fully inserted into the back plane connector station devices may be connected to that cabinet However if the cabinet is equipped with two power supply units a maximum of 120 station devices may be connected to that cabinet See the configuration section of the General Description Guide for more ei If a cabinet is equipped with a single power supply unit PSU B a maximum of 56 details 23 16DLI CARD There are no options to select on this card Insert up to and including seven 16 DLI cards per cabinet as needed into any universal slots see note below See Figure 3 2 Push firmly in the middle of both card ejectors on each card to ensure that it is fully inserted into the back plane connector station devices may be connected to that cabinet However if the
48. 4 OfficeServ 500 Installation Guide Ed 01 J1 SWI P3 P4 IE Pl P7 1588 J6 TTM3D Figure 3 24 ITM3 Card Do not insert this card with system power ON SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 36 MGI3 CARD CHAPTER 3 Installing Printed Circuit Cards The MGI3 card supports the VoIP Gateway which enables telephone calls through the Internet Since the MGI3 card cannot support the H 323 protocol by itself the MGI3 card shall always be used together with the MCP2 card When mounted with the ITM3D board the MGI3 card can support up to 16 Internet telephone VoIP ports by adding 8 channels of Internet telephone ports Up to 2 cards can be mounted per cabinet and the mounting location is not limited The features of the MGI3 card such as LAN port connection RS232C connection Reset button and jumper setting are identical to that of the ITM3 card except for the front panel LED feature The LED display of the MGI3 card is shown in Figure 2 12 below Figure 3 25 LED Display of the MGI3 Card Table 3 1 LED Display of the MGI3 Card On Off Blink LED Color Description LED On Off Blink PWR Light Displays the power supply status of the MGI3 board Green On Power is supplied normally Off No powe
49. BLOCK mode Therefore the functions shall be always used in ENBLOCK mode SAMSUNG Electronics Co Ltd Page 12 7 CHAPTER 12 Networking Description and Programming Procedure OfficeServ 500 Installation Guide Ed 01 2 Page 12 8 CLI Table When a call is dialled to PRI the specified number of Program 323 is used as a caller ID When a call is dialled to networking PRI node number amp station number are always used irrespective of this option NB Type When a call is dialled to PRI the type of dialled number is specified When a call is dialled to networking PRI the connected number is identified and processed as node number amp station number irrespective of this option Program 714 Set the Connection of Direct Station Dialling Set connection for the received number The numbers of station station group trunk line trunk line group auto route selection and networking dial are specified to connection destination Each field of the program is described below 001 999 Index number of up to 999 digits DGT Specifies a number to be received refers to numbers 0 to 9 MOH SOURCE Specifies MOH to be used for hold depending on the received numbers In case of None it operates according to Program 409 1 6 Assigns the recipient according to the ring answer mode 1 6 B represents the station trunk line station group trunk line group auto route selection use code or the networking di
50. C connection is a standard computer type power cord see Figure 2 6 Use only the mains lead supplied with the OfficeServ 500 system that has the warning label affixed Power Input Location Figure 2 5 OfficeServ 500 Power Input Location Do Not Connect AC Power To The System see Chapter 4 Power Up Procedures WARNING OfficeServ 500 Power Supply Unit PSU B The OfficeServ 500 PSU B is the power supply for the OfficeServ 500 cabinet s see Figure 2 3 A second PSU B or a PSU60 is required if more than 56 stations are installed in a cabinet This same rule applies to each cabinet Insert the first PSU in the first slot of the cabinet Before a PSU is installed verify that the power switch is in the proper voltage setting position 110V or 220V required If two or more PSU s are to be installed use the same procedure for each card Do Not Connect AC Power To The System see Chapter 4 Power Up Procedures WARNING SAMSUNG Electronics Co Ltd Page 2 11 CHAPTER 2 Installing Single Multiple Cabinet Configurations OfficeServ 500 Installation Guide Ed 01 Before the second PSU can be installed it will be necessary to remove the safety cover plate that protects the power socket on the backplane Be sure that AC power is not applied before touching this plate Undo the screw holding the cover plate to remove it 8 3 External 48VDC Battery Source To reduce risk of fire and injury to person
51. CP card to a system that uses the MCP2 card Preparations Prepare the MCP2 card Prepare SCP2 and the required LCP2 card for the L system Prepare a smart media equipped with the program that operates in the system using MCP2 Backup the DB data to the smart media for security Convert the DB data of the previous system using the PCMMC Tool before use Prepare the related modules to use new features such as wireless LAN IP Phone and Large LCD Phone The 8WLI WBS24 and the WIP5000M phone are the modules used for wireless LAN The IP phone and the Ethernet line modules are used for the IP Phone feature Prepare the related modules for the Large LCD Phone Procedure 1 Turn the system power off 2 3 4 5 6 7 8 Replace the SCP card with the SCP2 card and replace the LCP card with the LCP2 card The option cards mounted on the universal slots can be used without modification or relocation Mount the daughter boards of MCP on the same location of MCP2 the daughter boards of SCP on the same location of SCP2 and the daughter boards of LCP on the same location of LCP2 Mount or connect the additional modules to be used in the MCP2 system configuration Change the LAN port from IOM to the MCP2 front panel LAN port Only SIO2 and SIO3 may be used for system I O ports Relocate the required ports Check if the PCMMC port needs to be relocated O SAMSUNG Electronics Co Ltd Page 10 1 CHAPTER 10 Adding Ca
52. Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 10 Adding Cards To The System Multiple Cabinet System ch QUE slolelzslelelslele See ee EE alallala lalalala e ojljojlojojlojojlojojo reel cf slolelslelelslsle E GH ee AININ la aja a a O ojpjojojo ofjojojo o Single Cabinet System pato A SZE perf oT CI RR slolelslelelslelele slolelslelelsles si eee GE LL le KE o eS elelelelele lale s slelelelelelsls 3 SIS ISIS S SISIS S ojpojojojofjojojo gt KS U U U Figure 10 1 Cabinet Slot Numbers SAMSUNG Electronics Co Ltd Page 10 3 A CHAPTER 10 Adding Cards To The System OfficeServ 500 Installation Guide Ed 01 GRADING THE OfficeServ 500 FOR DTMF RECEIVERS DSP s Digital Signal Processors are used in the OfficeServ 500 system as DTMF receivers Considerations must be made when using features of the system that require DSP s Different system traffic patterns may affect the availability of common resource DSP s Calculating or grading these DSP s is required to ensure adequate system performance There are 4 DSP s on ea
53. Connecting Station Equipment OfficeServ 500 Installation Guide Ed 01 4 Page 6 4 IP Telephone The IP Telephone is a terminal that allows calls through the Ethernet LAN network The link between the extension subscriber terminal digital phone connected to the system and the IP phone connected to LAN is established as described below The connection between the digital phone and the IP phone is established using the IP address through the LAN connected to MCP2 When connected the digital phone converts the analog voice data to the PCM voice data and sends it to the MGI1 2 3 card through the 16DLI card The PCM voice data is converted to packet data at the MGI1 2 3 card and transferred to the IP phone The IP phone converts the packet voice data to the analog voice data and sends out the analog voice data through the handset or speaker The analog voice data entered into the IP phone is likewise converted to packet data transferred to the MGI1 2 3 card converted to PCM voice data transferred to the digital phone trough the 16DLI card and finally converted to analog voice data at the digital phone Therefore to use a IP phone prepare the IP Telephone MGI1 2 3 card and connect MCP card to the Ethernet port Refer to the programming guide for appropriate settings before use OfficeServ 50
54. DLI 16 SEPUs to 16 DLI and no power would be supplied to the 16MWSLI card The 16MWSLI card will be recognised if reviewed in MMC 806 However it would indicate P N A second PSU 60B or PSU 60 must be installed to power the 16 MWSLI ports Each cabinet on the OfficeServ 500 has two power supply slots the first of which must contain a PSU B and can supply up to 56 station devices or Station Equivalent Power Units SEPU The second PSU slot can contain either a PSUB or a PSU 60 and can supply up to 64 station devices or SEPUs Several interface cards other than station cards consume 48V power and the consumption of these cards is rated in SEPUs The table below indicates the SEPU rating of all the cards that consume 48V The table also shows the loading priority of the cards for example if a system uses 56 SEPUs and adds a Cadence card the system will turn off 8 SEPUs on lower priority cards to enable the Cadence to run Page 4 2 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 4 Power Up Procedures Card Type SEPU Rating Priority Level Notes 16 DLI 16 1 8 DLI 16 1 Each B channel counts as a port 16 SLI 16 1 16 MWSLI 16 1 SVMi 8 8 1 SVMi 16 8 1 8 SLI 8 2 8WLI 32 1 8 MWSLI 8 2 4 BRI 8 2 Each B channel counts as a port SLI 4 4 E amp M 4 4 DID 4 4 GTRK 4 4 MGI1 MGI2 8 2 To determine which PSU is supplying each card or to determine if a card is turn
55. EMOVING THE SVMI 8 CARD To remove the SVMi 8 card from the system to relocate or replace it please follow these steps 1 InMMC 754 set VM Halt status to OFF this will stop further processing by the SVMi 8 and protect the HDD when the card is removed 2 Check that the ACT LED is OFF and then turn the system OFF 3 Remove the SVMi 8 card SAMSUNG Electronics Co Ltd Page 11 3 CHAPTER 11 SVMi 8 Set Up OfficeServ 500 Installation Guide Ed 01 UP this page is intentionally left blank Page 11 4 SAMSUNG Electronics Co Ltd CHAPTER 12 Networking Description and Programming Procedure 1 Networking This function allows you to operate multiple systems as if operating a single system Digital phone Ta TT Digital phone Figure 12 1 OfficeServ 500 Networking Conceptual Diagram The networking function of OfficeServ 500 system uses Q SIG Q Signaling and is classified into PRI Networking and VoIP Networking depending on the connection method between each system OfficeServ 500 system using Q SIG provides the functions below 1 1 Provide Q SIG Basic Function Networking of the OfficeServ 500 system provides basic Q SIG functions as follows 1 Intercom Call This function allows you to call a station of another system as if calling the station in the same system 2 Incoming Call This function allows you to forward incoming trunk line calls to a station of another system without any additional o
56. F Connections MOH Source MISC Board When connecting a customer supplied music source to the MISC card an approved MOH Isolation unit must be installed Do not attempt to connect commercial AC power to the MISC card CALITION O SAMSUNG Electronics Co Ltd Page 7 1 CHAPTER 7 Connecting Optional Equipment OfficeServ 500 Installation Guide Ed 01 2 EXTERNAL PAGING Each MISC daughter board provides a voice pair and a dry contact pairs to be used with customer provided paging equipment Connect the customer provided paging equipment to the page output pins of a MISC daughter board see Figure 7 2 The relay must be assigned to the page zone in MMC 605 The page voice pair is 600 ohm impedance When the amplifier page input is not 600 ohm use an impedance matching transformer The paging contact pairs are for control of low voltage circuits or amplifier output The contacts are rated at 24 VDC 1 amp When connecting customer supplied external paging equipment to the MISC card the audio connections to the amplifier must be isolated using an approved Audio Line Isolation unit CAUTION If the MISC card relay s are also being used to control the paging equipment a DC line isolation unit must be installed Do not attempt to connect commercial AC power to the MISC contacts PAGE RELAY PAGE RELAY CONTACT CONTACT DN363 DN363 MSC CUSTOMER PROVIDED PAGING AMPLIFIER CUSTOMER PROVIDED PAGING AMPLIFIER
57. FOR LOUD BELL Figure 7 2 MDF Connections Paging Loud Bell AMP to MISC Board Page 7 2 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 7 Connecting Optional Equipment 3 COMMON BELL A customer provided loud ringing device can be controlled using a dry contact pair on a MISC daughter board See Figure 7 3 By using MMC 204 programming allows for interrupted or continuous operation of the contacts The interrupted selection follows the trunk line ring cadence After connecting a common bell you must assign it in MMC 601 to a group as a ring destination by using the code for common bell The basic steps for common bell operation are the following a Wire the loud ringing device to the common bell control contact pair b Set contacts for continuous or steady operation c Program the hunt group to include the common bell d Assign the trunk to ring the hunt group containing the common bell Common bell control can be used with station hunt groups individual stations and Universal Answer Contacts are rated at 24 VDC 1 amp Line Isolation unit must be installed Do not attempt to connect commercial AC power When connecting customer supplied common bell to the MISC card an approved DC to the MISC contacts CAUTION COMMON BELL RELAY CONTACT DN3801 Figure 7 3 MDF Connections Common Bell to MISC Board 4 RING OVER PAGE When a customer provided paging system is installed inc
58. Ltd Page 4 5 CHAPTER 4 Power Up Procedures 2 1 Page 4 6 OfficeServ 500 Installation Guide Ed 01 PSU Fusing Fuse PSU B PSU 60 Comments AC In Active F1 AC 250V 5A F1 EE Sub has single AC In fuse AC In Neutral F2 AC 250V 5A F2 Battery F4 AC 125V 3A F4 AC 250 2A 48 F3 AC 125V 3A F3 AC 250 2A Turn the AC power switch to the ON position on each of the expansion cabinets Turn the AC power switch to the ON position on the main cabinet The MP LED on the MCP pack will light steady and the SM LED will start flashing to confirm the presence of power and that the processor is booting The MP LED will start to flash and the SM LED will go steady when the MCP MCP2 has booted At this time the Tx Rx LED HDLC LEDs on the SCP SCP2 and LCP LCP2 cards will flash to indicate the presence of power and that the local processor is running If the SM LED on the MCP MCP2 does not light or flash then the system does not recognize the SmartMedia card Power down the main cabinet replace the SmartMedia card and repeat the power up process If the power up problem is not corrected power down and remove the MCP MCP2 card Check the MCP MCP2 to ensure it is configured correctly Remember the MCP MUST have a ESM IPM and SCP SCP 2 installed to operate in a multiple cabinet system and that the SmartMedia card must contain L version software If none of the LEDs on the MCP MCP2 illuminate unplug the system disconnect the expansion cabin
59. M memory of SCP2 is 4 MB Therefore the SCP2 card shall be used for features such as LCD Phone IP Phone and Wireless LAN which require much memories The use configuration of Daughter boards within the card is identical to that of the SCP card SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 3 Installing Printed Circuit Cards 5 LCP CARD The OfficeServ 500 Local Control Processor LCP is used when the system is expanded to more than one cabinet The LCP is the processor for the second and or third OfficeServ 500 cabinet s and communicates via a high speed data link to the MCP The LCP installs in the MCP LCP slot in the second or third cabinets of a multiple cabinet system The LCP can have three daughter boards installed as indicated by the table below SWITCH CONTROL PROCESSOR LCP DAUGHTER BOARD CAPABILITIES Position Types of Daughter Boards allowed per position LOC1 MFM RCM LOC2 MFM RCM MISC LOC3 MFM RCM VA Only one of any type of daughter board may be installed on any processor card O L C EE P P3 P12 MFM RCM P10 MR Ms kel PI EVE P6 Sp SI se sg CR misc PF Sp A Cor
60. MCP card is booting Flicker Indicates normal operation SM OFF indicates the SmartMedia card is not installed or not recognized ON indicates the SmartMedia card is inserted and recognized Flicker indicates the SmartMedia card is being accessed LAN OFF indicates a LAN is not installed or power is off ON indicates the LAN board is booting Flicker indicates normal operation Si Not used S2 SCP HDLC Rx Receive Status OFF indicates that there is no link from the SCP card ON indicates that the link from the SCP card is being set up Flicker indicates a message has been received S3 SCP HDLC Tx Transmit Status OFF indicates that there is no link from the SCP card ON indicates that the link from the SCP card is being set up Flicker indicates a message has been transmitted S4 LCP C 2 HDLC Rx Receive Status OFF indicates that there is no link from the LCP card ON indicates that the link from the LCP card is being set up Flicker indicates a message has been received S5 LCP C 2 HDLC Tx Transmit Status OFF indicates that there is no link from the LCP card ON indicates that the link from the LCP card is being set up Flicker indicates a message has been transmitted SAMSUNG Electronics Co Ltd Page 3 3 CHAPTER 3 Installing Printed Circuit Cards OfficeServ 500 Installation Guide Ed 01 S6 LCP C 3 HDLC Rx Receive Status OFF indicates that there is no link from the LCP card ON indicates that the link fro
61. N EXISTING SYSTEM nes 10 5 CHAPTER 11 SVMi 8 Set Up 1 INTRODUCTION iii ii aia rara ran ainia 11 1 lt WED ANdicatiONS tati 11 1 12 RESET BUON euer SSES bb 11 1 1 3 Power Requirements 11 1 2 INSTALLATION OF THE SVMI 3 anne 11 2 3 TESTING THE HARDWARE uereg Essai cnica air 11 3 4 REMOVING THE SVMI 8 CARD 11 3 CHAPTER 12 Networking Description and Programming Procedure AAA o A 12 1 1 1 Provide Q SIG Basic Function seen 12 1 1 2 Provide Inherent Additional Function through Q SIG ccccccssececeeeeeseeeeeeeeeesees 12 2 1 3 Provide Q SIG Additional Funchon no cnn nnnnnnnnnn 12 3 2 Programming Method Sae e ear eare aaa ais an enaa ar aeaaaee aran Lapa aani Lauan aE Eae anaa 12 5 2 1 Secure and Define System Components 12 5 2 2 Unify Phone Number System ss 12 5 2 3 Route Incoming and Outgoing i 12 7 2 4 Items Required for Additional Features 12 10 Page XII SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 Table Of Contents 2 5 Programming Example nnanet ananman nnna 12 14 LIST OF FIGURES Figure 1 1 Figure 2 1 Figure 2 2 Figure 2 3 Figure 2 4 Figure 2 5 Figure 2 6 Figure 2 7 Figure 2 8 Figure 2 9 Figure 3 1 Figure 3 2 Figure 3 3 Figure 3 4 Figure 3 5 Figure 3 6 Figure 3 7 Figure 3 8 Figure 3 9 Figure 3 10 Figure 3 11 Figure 3 12 Figure 3 13 Figure 3 14 Figu
62. N telephones can be connected and used in the Premium configuration The modules below shall be prepared to use the wireless LAN telephone Refer to the WBS24 user guide for the wireless LAN service 8WLI card For future System connection card WBS24 For future Base Station WIP5000M For future Wireless terminal Before mounting the 8WLI card to the system note that the OfficeServ 500 system shall be configured in the Premium configuration and that only one card shall be installed per system The 8WLI card shall only be mounted on SLOTI SLOT2 or SLOT3 of the cabinet and shall not be mounted on any other slots Two 0 64mm Twisted pair cables Max length 600 M or two 0 40mm Twisted pair cables Max length 400 M shall be used when connecting the 8WLI card and WBS24 8WLI uses the 50 pin champ connector and WBS24 uses the 8 pin RJ 45 connector GE OfficeServ 500 Configuration with MCP2 card OfficeServ 500 M OfficeServ 500 L Number of 8WLI card 1 1 Maximum number of WBS24 8 8 Maximum number of users 48 48 Number of simultaneous calls 32 32 S2 S3 S4 S5 S6 S7 S8 S9 S10 P P Si S Ss 8 U U W L B_B y x fl QU MU A Sie N _ 7 Figure 5 8 Wireless LAN System Configuration Diagram Page 5 12 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 5 Connecting Trunk Line Circuits Wiring Diagram between 8WLI and WBS24 123 45 67 8 RJ 45 CONNECTOR
63. NET inn 2 6 6 RACK MOUNTING AN OfficeServ 500 CABINET NEEN 2 7 7T GROUNDING de hrs te Mann da ila cest ES 2 9 7 1 Alternative Earthing Arrangements 2 9 8 POWERGONNECTIONS lll ela lora ea 2 11 8 1 AC Power Cord Assembly ss 2 11 SAMSUNG Electronics Co Ltd Page VIII OfficeServ 500 Installation Guide Ed 01 Table Of Contents 10 8 2 OfficeServ 500 Power Supply Unit DSP 2 11 8 3 External 48VDC Battery SOUrce nn nn nnnnnnnnnnnos 2 12 RINGER CARD INSTALLATION uen roc 2 14 91 TO CEET 2 14 MDF CABLING ii aa 2 16 CHAPTER 3 Installing Printed Circuit Cards N O a WO N 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 MCP CARD nr 3 2 MCP2 CARD ine 3 7 SCP CARD NEE 3 8 A O OO OO u peia adret E e Nra P eunda aene E Ndoa nE a aneiens nenian 3 10 LOP CARD S A E E E EE 3 11 LOP2 CARD E 3 13 ESM BOARD genee EE A ENEE SEENEN reucdu sante acte nnee acini 3 14 IPM BOARD EE 3 15 LAN BOARD coord 3 16 MISC BOARD iiia liana arianna 3 17 SCM BOARD boo sic ces cies ee cateassenassccencenascauusetarsscboatsessavaeddetseanateducadselsadgectonssdvantantecieatsdecian 3 19 MEM BOARD ili 3 20 ROM AAA delineare svol aina 3 21 MODEM BOARD rien 3 22 JOM BOARD iii ivan isernia 3 23 TRKIBCARD case saatseetsentatscateedstcadstsddsevetandd ackeedaadsuasianuasanactaatavt
64. R 11 SVMI 8 Set Up 1 1 1 2 1 3 INTRODUCTION This section provides the additional steps required to set up the SVMi 8 card for operation in the iDCS telephone system Included is information regarding the Activity LED HDD LED Reset Button and Power Requirements LED Indications There are two LEDs on this card The HDD LED will flash green whenever the hard disk drive is being accessed The Activity ACT LED has various indications as defined in the table below ACT LED SVMi 8 STEADY RED SVMi 8 software is not running OFF SVMi 8 software is running no calls are in progress STEADY GREEN SVMi 8 software is running one or more calls are in progress FLASHING GREEN SVMi 8 software is initializing SVMi 8 is not ready to process calls RESET Button The red button marked RST is the Reset button Immediately after plugging in the SVMi 8 card and turning the iDCS power switch ON you MUST press this button to initialize SVMi 8 See installation step 6 below Pressing this button during operation will disconnect all callers in SVMi 8 and restart the card POWER Requirements It is important to understand that all the power to run this self contained Voice Mail system comes from the phone system power supply Each of the DCS phone system power supplies are rated according to how many stations they will support When SVMi 8 is installed in the iDCS it counts as 8 stations of the PSU rating regardless of the number o
65. SAMSUNG Electronics Co Ltd WBS24 Side 8WLI Side Base Si ignal RIAS Pin Station t g 50P Champ Pin 4 1 D Channel data 5 26 1 6 27 Sync line 3 2 4 4 D Channel data 5 29 2 6 30 Sync line 3 5 4 7 D Channel data 5 32 3 6 33 Sync line 3 8 4 10 D Channel data 5 35 4 6 36 Sync line 3 11 4 13 D Channel data 5 38 5 6 39 Sync line 3 14 4 16 D Channel data 5 41 6 6 42 Sync line 3 17 4 19 D Channel data 5 44 7 6 45 Sync line 3 20 4 22 D Channel data 5 47 8 6 48 Sync line 3 23 Figure 5 9 WBS24 8WLI Wiring Diagram Page 5 13 CHAPTER 5 Connecting Trunk Line Circuits OfficeServ 500 Installation Guide Ed 01 UP this page is intentionally left blank Page 5 14 SAMSUNG Electronics Co Ltd CHAPTER 6 Connecting Station Equipment 1 SAFETY PRECAUTIONS To limit the risk of personal injury always follow these precautions before connecting telephone circuits a Never install telephone wiring during a lightning storm b Neverinstall telephone jacks in a wet location unless the jack is specifically designed for wet locations c Never touch non insulated telephone wires or terminals unless the telephone line has been disconnected at the network interface d Use caution when installing or modifying tel
66. Stee I I I I EI ER 4 Mounting Screw Holes PSU B PSUGO Set Set Slot3 Slot4 Slot5 Slot amp Se Slot8 Slot9 SCP MCP LCP PSU B Figure 2 4 Securing Cabinet in a Rack The 50mm gap between cabinets requires a longer Cabinet Interconnect a Cable CICR than usual for multiple cabinet installations 5 Re attach Grounding bar to each cabinet and connect them together as described in Section Grounding As the system is for Technician access only when replacing the front cover the screws must be tightened using a screw driver SAMSUNG Electronics Co Ltd Page 2 8 OfficeServ 500 Installation Guide Ed 01 CHAPTER 2 Installing Single Multiple Cabinet Configurations 7 GROUNDING The Protective Earth PE connection to the OfficeServ 500 cabinet is provided via the three core mains lead The protective earth to the expansion cabinets is also provided by the 3 core mains lead supplied with the LCP card linking the expansion cabinets to each other and the main cabinet Ensure that the AC power point which the OfficeServ 500 system is connected to is suitably grounded Hazardous telecommunications network voltages may be present if analogue trunks are connected Ea
67. Us Power Requirements Card Type Ports SEPUs 16DLI 16SLI 16MWSLI 8DLI 16 8SLI 8MWSLI BRI SO SVMi 8 SVMi 16 MGI1 MGI2 8 8BSI 24 8WLI 32 4SLI E 8 M 4 PRI AA TEPRI 8 Trunk 6 Trunk O use 5Volts only To check the status of PSU installation use MMC 806 PSU Card Pre install Option P 1 means PSU B is installed in the first slot P 2 means PSU B is installed P B means PSU 60 is installed and is in the second slot P N means i no SEPUs have been allocated to this card ii the card does not require 48V power or 111 the PSU is faulty if installed XX means the number of ports on the card which have been supplied 48V power O SAMSUNG Electronics Co Ltd Page 4 1 CHAPTER 4 Power Up Procedures OfficeServ 500 Installation Guide Ed 01 1 2 1 LCD Example CRT ST P 2 08 16DLI gt 16 DLI Where C 1 16 DLI card is installed in Cabinet 1 S 7 16 DLI card is installed in slot 7 P 2 16DLI is running on the PSU in the second PSU slot 08 only 8 ports have service available Example Single Cabinet with a single PSU 60B installed The following interface cards are installed TEPRI slot 1 8BSI card slot 2 16DLI card slot 3 16DLI card slot 4 16MWSLI card slot 5 AA Card slot 6 The total SEPUs of installed cards 0 24 16 16 16 0 72 In this case the 48V power to support these cards would be allocated on the following basis 24 SEPUs to 8BSI 16 SEPUs to 16
68. Y TRUNK B CARD Figure 5 1 MDF Connections Page 5 2 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 5 Connecting Trunk Line Circuits 25 PAIR CABLE WITH FEMALE CONNECTOR TO ANY or B TRK CARD FUNCTION CIRCUIT PIN trunk line TIP gt 26 trunk line RING 1 trunk line TIP 27 trunk line RING 2 28 3 trunk line TIP a 29 trunk line RING 4 trunk line TIP 30 trunk line RING 5 31 6 trunk line TIP e 32 trunk line RING 7 trunk line TIP e 33 TELCO PROVIDED trunk line RING 8 NETWORK MDF 34 9 trunk line TIP 7 35 trunk line RING 10 trunk line TIP E 36 trunk line RING 11 NO OTHER CONNECTIONS CONNECT TO ANY CIRCUIT NOTE ONLY LOOP START LINES CAN BE CONNECTED TO A 6TRK or 8TRK CARD ON ANY 6TRK or B TRK CARD Figure 5 2 MDF Connections Loop Start Line to 6 or 8Trunk Card SAMSUNG Electronics Co Ltd Page 5 3 CHAPTER 5 Connecting Trunk Line Circuits OfficeServ 500 Installation Guide Ed 01 3 E amp MTIELINES Using two pair twisted Each E amp M circuit requires 3 pairs 6W using 0 50 mm Jumper wire cross connect each E amp M tie line to the E amp M card port of your choice see Figure 5 3 25 PAIR CABLE WITH FEMALE CONNECTOR TO ANY E amp M CARD FUNCTION CIRCUIT PIN Tx1 TIP 26 Tx1 RING 1 E1 27 M1 2 Rx1 TIP 28 Rx1 RING i 3 Tx2 TIP 29 Tx2 RING 4 E2 3
69. aded to the LAN Board on the MCP card and then transferred to the SmartMedia card Once the files are loaded onto the SmartMedia card they can be manipulated with MMC 818 as before 2 DATABASE MANAGEMENT The customer database of the OfficeServ 500 is stored in super capacitor backed RAM in up to three locations depending on the system configuration In an M version system it is only stored on the MCP itself and for the additional features provided with the addition of a LAN board their specific part of the database is stored on the LAN board itself In an L version system the customer database is split between the MCP card and the IPM board with the additional features provided with the addition of a LAN board their specific part of the database is stored on the LAN board as in the M version The Customer database can be saved to the SmartMedia card using MMC 815 where it is stored as a single file This save can be performed manually or the system can be programmed to save the database automatically at a designated time every day Using PCMMC the database can be downloaded from the system and stored on the PC or it can be uploaded from the PC to the system The database uploaded from PCMMC is not stored in the SmartMedia card but is loaded directly into active memory Page 9 2 SAMSUNG Electronics Co Ltd CHAPTER 10 Adding Cards To The System 1 System Upgrade The operations below are required to change the previous system that uses M
70. al number that has the same number as the received number CW Sets whether to park the call when the receiving station is busy Not used in networking feature DELETE The number of digits deleted from the forepart of the received number that is sent through the trunk line when the recipient is trunk line trunk line group auto route selection use code or the networking dial number NAME Name of the station direct dial conversion table used for identifying received numbers SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 12 Networking Description and Programming Procedure 2 3 2 Set Call Path 1 4 6 Program 210 System On Off LCR ENABLE Shall be set as ON to use the auto route selection feature Program 310 Set Auto Route Selection Class Sets the class applied when using the auto route selection route Uses the default value 1 when there is only one route connected to another system Program 603 trunk line Group Groups shall be assigned based on systems connected to the TEPRI card for PRI networking All VoIP signaling trunk lines shall be assigned to one group for VoIP networking VoIP signaling trunk line represents the virtual trunk line assigned in Program 724 VOIP NET DIAL NO Program 710 Auto Route Selection Digit Routes are assigned according to the digit when using auto route selection Fields of the program are described below 0001 2000 Index number represe
71. alized Voice Mail This function enables you to install only one voice mail in the network You shall use the dedicated voice mail SVMi 8 16 of the subscriber card type to use this function Page 12 4 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 12 Networking Description and Programming Procedure 2 2 1 2 2 Programming Methods Programming shall be performed in the following steps to use the networking functions of the OfficeServ 500 system Especially the system of phone numbers shall be unified and incoming outgoing paths shall be programmed in the given method so as to use the networking functions properly Secure and Define System Components The required system components for networking are defined as follows 1 2 3 4 Program 821 Set Networking trunk line For PRI networking TEPRI card shall be specified for networking If the OfficeServ 500 systems are connected by using TEPRI not trunk line the one switch within the card is set to the NT mode and the other switch is set to TE mode System based clock shall be defined in Program 828 PRI of the NT mode operate in the ENBLOCK mode only Program 830 Set System IP Address The IP address of the system shall be set to use VoIP networking Set the IP address default gateway subnet mask of the system and restart the system Then changed IP address will be applied Program 831 Set MGI P
72. allation Guide Ed 01 CHAPTER 3 Installing Printed Circuit Cards 37 MGI1 MGI2 CARD The MGI card supports the VoIP Gateway which enables telephone calls through the Internet The MGII card serves as a gateway which connects calls between the legacy terminal SLI DLI and the IP terminal IP Phone and provides the Internet telephone VoIP port with 16 channels The MOD card supports calls connecting to a Remote System station IP phones for telecommuting or to the Trunk Line and provides the Internet telephone VoIP port with 16 channels There are two types of MGI card the MGII card and the MGI2 card which were classified by their serviceable ranges Up to 5 cards can be mounted per cabinet and the mounting location is not limited Up to 80 ports for OfficeServ 500 M and up to 160 ports for OfficeServ 500 L are supported for VoIP calls M G I ENR RUN 0 SRV DSP IPC MOD P4 J3 P1 S1 Figure 3 26 MGI 1 2 Card SAMSUNG Electronics Co Ltd Page 3 47 CHAPTER 3 Installing Printed Circuit Cards LED Indicator PWR LED Color Light green OfficeServ 500 Installation Guide Ed 01 LED On Off Blink Function Displays the power authorization status On Power is normally authorized to the MGI card Off Power is not authorized to the MGI card RUN Light green Displays the operation status of the MGI card Blink The MGI card is normally operating Off The MGI card is not
73. arameter Address The IP address of the MGI card to be used as voice channel shall be set to use VoIP networking Set the IP address default gateway subnet mask to each MGI card and restart the card Then changed IP address will be applied Program 615 Set MGI Group The MGI card to be used as voice channel shall be set to use VoIP networking Select Networking from USER options Set the phone number of the MGI channel to be used as voice channel when VoIP networking calls are set as group members Unify Phone Number System The phone number system of the networking shall be unified as described below Link ID System node ID that can identify each system connected by networking It shall not be duplicated Signal G W For VoIP networking the IP addresses of all connected system as well as the system for the networking shall be specified SAMSUNG Electronics Co Ltd Page 12 5 CHAPTER 12 Networking Description and Programming Procedure OfficeServ 500 Installation Guide Ed 01 2 3 Page 12 6 For PRI networking if node number for the networking is specified normal calling can be made However to use the functions supported by the system the node number of the other systems shall be specified For VoIP networking the node numbers of IP addresses of all connected systems as well as the system for the networking shall be specified to make a call When a call is connected to networking trunk line the OfficeSer
74. ard has no selectable options and installs in position LOC3 of the MCP MCP2 card when the system has one cabinet installed see Figure 3 1 If the system has more than one cabinet the MISC board must be installed in position LOC2 of the SCP SCP2 card see Figure 3 3 or position LOC2 of the LCP LCP2 cards Up to 3 MISC boards can be installed in a system one on the MCP MCP2 or SCP SCP2 and one on each LCP LCP2 The MISC board is required to provide external music inputs external page outputs and programmable relay contacts To install the MISC board remove the two 2 screws holding the MCP MCP2 or LCP LCP2 protective casing together see Figure 3 6 or remove the 4 screws holding the SCP SCP2 case together see Figure 3 10 and separate the two halves of the case Place the MISC board face down over the two connectors taking care to properly line them up and press gently on the back of the board to seat it The MCP MCP2 LCP LCP2 SCP SCP2 case can now be reassembled if all required daughter boards have been installed iieii sage T Da KR D hi CU EBaesa P2 y OOO ops b SI Misc F wine e JE alll NN n 21 me PALO 5 5 EL
75. binet to ensure stable reception of clocking from the primary and secondary sources There are two RJ 45 modular jacks on the face of the card The top one is labeled TI but is the socket to use for PRI The PRI software supports ETSI ISDN only The bottom RJ 45 socket can be used for El connections However the TI PRI RJ 45 can be also be used for El connections and this is recommended El service selection is achieved via dip switch settings Refer to the Chapter 5 for PRI E1 connection details The settings for El or PRI service are selected by a bank of dip switches as defined below see Figure 3 19 To access the dip switches you must remove the case by removing the 4 screws see Figure 3 20 and splitting the case A maximum of 9 TEPRI cards can be provided per system 3 per cabinet Push firmly in the middle of both card ejectors on each card to ensure that it is fully inserted into the back plane connector The TEPRI card has a recessed RESET button that will initialize the card manually if required The RS232 DB 9 connector on the face of the TEPRI card allows trace monitoring of the TEPRI functions This is used for testing purposes and only to be used under the supervision of SAMSUNG Technical Support 4 Do not insert this card with system power ON Page 3 34 O SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 30 1 TEPRI Card DIP Switch CHAPTER 3 Installing Printed Circuit Cards
76. cabinet is equipped with two power supply units a maximum of 120 station devices may be connected to that cabinet See the configuration section of the General Description Guide for more details VA 1 If a cabinet is equipped with a single power supply unit PSU B a maximum of 56 2 Keyset Daughter boards Will not work if connected to this card Page 3 28 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 3 Installing Printed Circuit Cards 24 SLI CARD There are no options to select on this card Insert as many SLI cards as are needed into universal slots 1 through 7 see Figure 3 2 Push firmly in the middle of both card ejectors on each card to ensure that it is fully inserted into the back plane connector This card will automatically detect DTMF or dial pulse signals from the single line telephone set There are no software or hardware settings required 56 station devices may be connected to that cabinet However if the cabinet is equipped with two power supply units a maximum of 120 station devices may be connected to that cabinet See the configuration section of the General Description Guide for more details 1 If a cabinet is equipped with a single power supply unit PSU B a maximum of 2 Do not connect devices with a total REN greater than 2 5 to any port on this card Except for Australia Australia use an external ringer 3 Do not connect devices with a total REN greater
77. call completion reservation can be maintained by setting the CC SVC RETN option to Y 9 DND amp DND Override When a networking call is received but the destination station is DND first the disconnection message will be sent back to the origination station At this time the message will be busy Then the origination system receives this message and sends the agreement message to disconnect the call And the origination station sends a busy tone so that the other party can know that the station is busy To terminate the call after giving DND tone for the set time the DND tone option in Program 823 shall be set to Y When the station of another system is called the DND tone is heard and DND status is indicated the DND can be overridden The DNDO option of Program 823 is set to Y and the DNDO CAPABL option number of the origination station shall be bigger than the DNDO PROTECT option number of the DND set station If the option numbers are same this function will not operate e This function operates only when the TRK INC DND option of Program 400 is On 10 Path Replacement When the networking call is connected you can press the PTHR button to replace a new path The PATH REPL option of Program 823 shall be set to Y 11 Centralized Voice Mail To have only one SVMi card installed in network and share with other systems the following items shall b
78. card to ensure that it is fully inserted into the back plane connector The SAMSUNG OfficeServ 500 system receives it clock information from ISDN services connected so a PRI or BRI card where installed must be installed in a lower slot number e g C1 S1 than the 8BSI card However if ISDN circuits are not installed the 8BSI card would normally be installed in slot 1 of the OfficeServ 500 cabinet The PRI supports ISDN PRI service Push firmly in the middle of both card ejectors on each card to ensure that it is fully inserted into the back plane connector ISDN cards like PRI and BRI use the external clock from the public network So when a SAMSUNG DECT system use PRI or BRI the system must align with the external clock as a slave Also installed 8BSI card uses the same clock as ISDN cards So the SAMSUNG DECT system determined the clock priority according to the card type and the position of slot At first according to the second clock priority and the 8BSI card has the lowest priority in the next priority Do not insert this card with system power ON A maximum of three 8BSI cards can be installed in slots 1 2 or 3 of same cabinet 21 4E amp MCARD This card has the following options Normal 34dB UP 6 0dB UP Tx Rx Tx Rx Tx Rx PORT1 ALL OFF ALL OFF J10 ON J30 ON J10 J20 ON J30 J40 ON PORT2 ALL OFF ALL OFF J11 ON J31 ON J11 J21 ON J31 J41 ON PORT3 ALL OFF ALL OFF J12 ON J
79. ch cabinet and 12 on each MFM processor daughter board These common use DSP s are shared and any card requiring a receiver will be able to make use of them After a DSP receives the expected number of digits it is released and then assigned to the next call The following devices 1 Analog DID 2 Analog E amp M 3 Digital El DID 4 Digital El E amp M 5 DISA trunks 6 8 SLI 7 8MWSLI 8 KDBSLI 9 16 SLI and 10 16 MWSLI require DSP resources to receive DTMF digits EXAMPLE CONFIGURATION A single cabinet system with 16 single line ports and an El with E amp M trunks There are 4 DSP s on the main cabinet In this configuration there would not be enough DSP s to provide an adequate number of DTMF receivers A MEM daughter board should be installed to add an additional 12 DSP s making the total number of DSP s in the system 16 Proper programming of trunks that require DSP s allows for better utilization of the available DSP s It is recommended that only the trunks on the El Span that are going to be used should be programmed El trunks that are not used should be programmed in MMC 411 as UNUSED This is because some E1 providers send an offhook or seized signal on unused or busied out El channels This will cause the iDCS to assign DSP s to trunks that are not in use Analog DID and E amp M trunks will not use a DSP unless the trunk is seized Unused analog trunks should not be cross connected until ready for u
80. conditions e g the tip and or ring conductor is crossed with a power line or the circuit is affected by lightning it is possible for hazardous potentials to appear across the tip and ring wiring coming into the OfficeServ 500 cabinet s from the outside plant e g overhead cables buried cables cable head pedestal These OfficeServ 500 trunk circuits are provided with both primary and secondary protection circuitry which will attempt to drain off these high voltages and currents to ground Obviously it is important to have a good source of ground connected to the OfficeServ 500 system to drain this energy off Also certain metallic analog circuits e g E amp M trunks require a flow of current to earth ground for normal operation and or to resolve fault conditions Again a good earth ground source is required by the OfficeServ 500 system These precautions are taken for safety reasons to protect personnel working on the OfficeServ 500 system and also for operational reasons to accommodate ground return and or ground referenced analog telephone circuits which require this solid earth ground connection for normal functioning Page 2 10 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 2 Installing Single Multiple Cabinet Configurations 8 2 POWER CONNECTIONS AC Power Cord Assembly The AC Power Cord Assembly plugs into the AC power socket which is located on the left side of the cabinet The A
81. customer supplied common bell to the MISC card an approved DC line Isolation unit must be installed When connecting a customer supplied IT equipment to the IOM card serial ports an approved Data Isolation unit must be installed Be careful when you press reset button while SVMI 16 is actually processing a call Data may be loss and files can be damaged Unplug all sources of AC and DC electricity from the system before attempting to expand cabinet Turn Off the switch on the OfficeServ 500 cabinets and at the AC Outlet Prior to any work on the system power supply SAMSUNG Electronics Co Ltd Page VII TABLE OF CONTENTS INTRODUCTION P rpose nana IRA cee dele lea Document Content and Organization SAI Z1 7 32 50 QUA geck Conventions ii id ia Il Reference onirica QF 4 17 BAA UA BSc Revision History teli Lia id V SAFETY CONCERNS Symbols o a RS a poli al ie elia VI Warning als da aisi Ea Aa rea ana VI Gautiohi et Ee alicell AT ind dada ig IIVI CHAPTER 1 Site Requirements 1 SITE REQUIREMENTS creino 1 1 CHAPTER 2 Installing Single Multiple Cabinet Configurations 1 UNPACKING AND INSPECTION iii 2 1 2 SINGLE CABINET INSTALLATION WALL OR FLOOR MOUNT sin 2 2 3 TWO CABINET INSTALLATION FLOOR MOUNT ie 2 4 4 THREE CABINET INSTALLATION FLOOR MOUNT in 2 5 5 ADDING AN OfficeServ 500 EXPANSION CABI
82. d then the default numbers may be four digits See section MCP of Chapter 3 for details on DIP switch settings Page 4 8 SAMSUNG Electronics Co Ltd CHAPTER 5 Connecting Trunk Line Circuits 1 SAFETY PRECAUTIONS To limit the risk of personal injury always follow these precautions before connecting Trunk Line Circuits a Never install telephone wiring during a lightning storm b Neverinstall telephone jacks in a wet location unless the jack is specifically designed for wet locations c Never touch non insulated telephone wires or terminals unless the telephone line has been disconnected at the network interface d Use caution when installing or modifying telephone lines SAMSUNG Electronics Co Ltd Page 5 1 CHAPTER 5 Connecting Trunk Line Circuits OfficeServ 500 Installation Guide Ed 01 2 TRUNK LINES LOOP START Using one pair twisted 0 50 mm jumper wire cross connect each loop start trunk line to the Trunk B 6TRK or 8TRK port of your choice see Figures 5 1 and 5 2 25 PAIR CABLE WITH FEMALE CONNECTOR TO ANY TRK B CARD FUNCTION CIRCUIT PIN trunk line TIP 26 trunk line RING i 1 trunk line TIP 5 27 trunk line RING 2 28 3 trunk line TIP 3 29 trunk line RING 4 TELCO PROVIDED trunk line TIP d 30 NETWORK MDF trunk line RING 5 31 6 NO OTHER CONNECTIONS O iO NOTE ONLY LOOP START LINES CAN BE CONNECTED TO A TRUNK B CARD ON AN
83. d with the slot numbers Label each terminating block to identify the cabinet slot and port numbers Use one pair twisted jumper wire to cross connect stations or lines to their associated port Figure 2 9 Connecting Champ Cables to the MDF boards SAMSUNG Electronics Co Ltd CHAPTER 3 Installing Printed Circuit Cards Before installing each card unpack it and check it for signs of physical damage If you detect any problem call SAMSUNG Technical Support immediately SAMSUNG Electronics Co Ltd Page 3 1 CHAPTER 3 Installing Printed Circuit Cards OfficeServ 500 Installation Guide Ed 01 1 MCP CARD The OfficeServ 500 Main Control Processor MCP controls the system operation The MCP installs in the MCP LCP slot in the first cabinet of the system The MCP is required for all system configurations The MCP has a 512 channel time switch matrix and positions for 3 daughter boards With a multiple cabinet system an ESM daughter board must be installed on the MCP to expand the switch matrix The MCP supports the following options e 8 position DIP Switch e Memory Backup On Off Switch e SmartMedia card slot 12 LED s e 3 daughter board positions one with external connections to support a MISC e MOH Internal Melody e 2SIO circuits O VOZ
84. e set e The SVMi card shall create voice mail for each station The voice mail uses the commands exclusively used for the SVMi card or can be automatically created by setting the MB option of Program 824 to Y It is recommended to change the unused voice mail with the commands of SVMi card even after the voice mail is automatically created e The station number assignments shall not be duplicated because the voice mail system is based on the station or station group numbers e Ifthere is no SVMi card in the system the VMMSG button is pressed to connect the voice mail directly The Use Remote VM option of Program 825 shall be set to Yes and the station number to connect the voice mail shall be set in the Remote VM Number option SAMSUNG Electronics Co Ltd Page 12 13 CHAPTER 12 Networking Description and Programming Procedure OfficeServ 500 Installation Guide Ed 01 When the trunk line call is received and the caller ID is to be sent to another system the node number shall be added in the front In order to remove this added node number when sending the caller ID to the voice mail the Remote CID Number option of Program 825 shall be set to Yes 2 5 Programming Example Figure 7 2 below shows the example of the networking programming that uses both of the PRI networking and the VoIP networking and is configured only with OfficeServ 500 systems Page 12 14 System A Node ID 091 ES
85. e wanted position and the system memory is cleared manually by using the Memory Backup switch Install the SmartMedia card Install daughter board s Set the MCP DIP switches on the card to the desired positions Insert MCP card in the CAB slot labeled MCP LCP see Figure 3 2 Push firmly at the top and bottom of the card to ensure that it is fully inserted into the back plane connector To prevent accidental damage to the MCP card the MCP LCP connector on the back plane is positioned to mate only with the MCP or LCP card SAMSUNG Electronics Co Ltd Page 3 5 CHAPTER 3 Installing Printed Circuit Cards Page 3 6 OfficeServ 500 Installation Guide Ed 01 Other interface cards will not mate with this connector and the MCP card will not mate with any other connector Do not insert this card with system power ON H amp 3107 5102 S103 SIO4 LAN PSU B PSUGO So Slow Set BS Slots SloL6 EE Se KO MEI PSU B PSU60 So Slotz Slots Slot4 Slots Slot Slot Set EE MCP LCP Figure 3 2 MCP Location SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 3 Installing Printed Circuit Cards 2 MCP2CARD The Main Control Processor2 MCP2 card is the main processor card with a 32 bit processor and controls the overall
86. ed in two versions OfficeServ 500 M and OfficeServ 500 L The files contained on each version of the SmartMedia card is detailed in the table below OfficeServ 500 M SmartMedia card will not operate in an OfficeServ 500 L system and vice versa Please ensure the correct version of SmartMedia is installed for each CAUTION system configuration 1 1 SmartMedia Files Type OfficeServ 500 M OfficeServ 500 L MCP MCPMXXXX PGM MCPLXXXX PGM MCP2 MCPMXXXX PRE MCPLXXXX PRE SCP LCP NA SCPDXXXX PGM LAN MCP Only LANVXXX LANVXXX TEPRI PRI_XXXX PGM PRI_XXXX PGM Customer Db Database mcp Database mcp SAMSUNG Electronics Co Ltd Page 9 1 CHAPTER 9 Software and Database Management OfficeServ 500 Installation Guide Ed 01 1 The above File names will be seen when viewing the files for downloading in MMC 818 2 XXXX or XXX indicates the program date or version number 3 When downloading or uploading the customer Database to the SmartMedia card the file 4 name will not be displayed in MMC 815 This is for reference only Software can be downloaded from the SmartMedia card to the cards listed above using MMC 818 and will be stored in those cards on board flash memory The cards will automatically reboot load and run the new software when the download process is complete Using PCMMC over a LAN connection to the system the software files can be uploaded to the SmartMedia card The files are first uplo
87. ed on or off MMC 806 will display the status of each card as listed below e Pl The card is running on PSU 1 e P2 The card is running on PSU 2 e PN The card is turned off 1 2 2 Large LCD Phone The power consumption of the large LCD phone is three times of general phone You can calculate the power consumption in the program as follows e The maximum power consumption becomes 24 port If the power consumption of the large LCD phones which are connected to the 16DLI card is more than 24 port the program isolate the power supply of the 16DLI card Example When 8 large LCD phone are connected to the 16DLI card The total power consumption is 24 port 3 x 8 So the other 8 port of the 16DLI card should not be connected SAMSUNG Electronics Co Ltd Page 4 3 CHAPTER 4 Power Up Procedures Page 4 4 OfficeServ 500 Installation Guide Ed 01 When you want to use all ports of the 16DLI card the following configuration is available Connect 4 large LCD phone and 12 general phone In this case the power consumption is 24 port 4 x 3 12 In case the large LCD phone is connected to the system and the power is not provided you have to check the port configuration of the 16DLI card which is connected the large LCD phone SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 4 Power Up Procedures 2 CONNECT POWER TO THE SYSTEM During the initial installation it is best to verify proper syst
88. em operation before plugging in any amphenol type cables to the MDF If you have already plugged the cables in unplug them Verify that the AC voltage at the dedicated electric outlet is in the range of 88 132 VAC or 220 240 VAC Verify that the AC voltage selection switch on the PSU is set for the proper voltage 220 or 240 VAC see Figure 4 1 110 220V selection switch Figure 4 1 Setting Voltage on PSU B The OfficeServ 500 PSU B employs fuses in both the AC ACTIVE and NEUTRAL legs Turn OFF the switch on the OfficeServ 500 cabinets and at the AC Outlet prior to any work on the system power supply CAUTION Make sure all of the AC power switches are in the OFF position Plug one end of the power cords into the power input connectors on the main cabinet and the expansion cabinets other into the dedicated polarized AC outlet or power strip Confirm that all expansion cabinets are connected to the main cabinet with CIC cables Verify that all power switches are in the OFF position Make sure all ofthe AC power switches in the OfficeServ 500 cabinets are in the OFF position Plug one end of the AC power cord into the power input connector on the main cabinet and the daisy chain power cords between the main and expansion cabinet s Plug the main cabinet AC power cord into the dedicated correctly wired AC outlet Confirm that all expansion cabinets are connected to the main cabinet with CIC cables SAMSUNG Electronics Co
89. ephone lines 2 iDCS PHONES The OfficeServ 500 system supports a two DLI card types for connecting phones DLI 8port 2B D and 16DLI 16port 1B Using one pair of twisted 0 50mm Jumper wire cross connect each phone to the DLI port see Figure 6 1 of the DLI card type used or plug into the KDB DLI of your choice For convenience the diagram below provides connection details for both DLI card types To reduce the risk of fire use only the supplied line cord or other approved line cord WARNING Because the OfficeServ 500 is a self configuring system if you connect a 18 button a phone to a DLI port that previously had a 28 button phone installed the existing data will be rewritten with 18 button phone default data MMC 723 This can be avoided if you first SAVE the phone data using MMC 721 This rule also applies to the DCS family of phones SAMSUNG Electronics Co Ltd Page 6 1 CHAPTER 6 Connecting Station Equipment OfficeServ 500 Installation Guide Ed 01 25 PAIR CABLE WITH FEMALE CONNECTOR TO ANY DLI CARD PIN CIRCUIT 16DLI 8DLI 26 1 DLI TIP DLI TIP 1 DU RING DLI RING 27 2 DLI TIP DLI TIP 2 DLIRING DLI RING 28 3 ONE PAIR TWISTED 29 3 DLI TIP DLI TIP STATION CABLE 4 DLIRING DLI RING 30 4 DLI TIP DLI TIP 5 DU RING DLI RING 31 6 32 5 DLI TIP DLI TIP 7 DLI RING DLI RING 33 6 DLI
90. er than 5 0 to this card Except for Australia Australia use an external ringer 3 Ringer Frequency External Ringer 20 Hz 80 Vrms SINUSOIDAL WAVE For Australia and Italy Internal Ringer 25 Hz 80 V RECTANGULAR WAVE For the other countries in Europe 4 This card does not contain OPX over voltage protection circuitry 5 SLI port feed voltage is nominally 50VDC Page 3 30 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 3 Installing Printed Circuit Cards 26 27 16SLI CARD There is an internal or external ring option on this card Insert as many 16SLI cards as are needed into universal slots 1 through 9 see Figure 3 2 Push firmly in the middle of both card ejectors on each card to ensure that it is fully inserted into the back plane connector This card automatically detects DTMF or dial pulse signals from the SLT Software and hardware settings are not required The 16SLI has no DTMF receivers it will share the system resources When the 16SLI cards are highly utilized with congested traffic the ratio of DTMF receiver will be decreased Therefore the MFM boards or daughter board should be added to a processor card to relieve the bottleneck station devices may be connected to that cabinet However if the cabinet is equipped with two power supply units a maximum of 120 station devices may be connected to that cabinet See the configuration section of the General Descri
91. es when considering a single or double power supply 6 SLI port feed voltage is nominally 50 VDC Page 3 32 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 3 Installing Printed Circuit Cards 29 16MWSLI CARD There are options as same as 16SLI CARD Insert up to seven 16MWSLI cards as are needed into universal slots 1 through 7 Push firmly in the middle of both card ejectors on each card to ensure that it is fully inserted into the back plane connector This card automatically detects DTMF or dial pulse signals from the SLT Software and hardware settings are not required The 16MWSLI supports industry standard message waiting lamps on single line phones The message waiting power supplied to the single line station in the iDCS is 90 to 100 VDC The 16MWSLI has no DTMF receivers it will share the system wide DSP resources for DTMF decoding When the 16MWSLI cards are highly utilized with congested traffic the ratio of DTMF receiver will be decreased Therefore the MFM boards or daughter board should be added to a processor card to relieve the bottleneck 1 If a cabinet is equipped with a single power supply unit PSU B a maximum of 56 el station devices may be connected to that cabinet However if the cabinet is equipped with two power supply units a maximum of 120 station devices may be connected to that cabinet See the configuration section of the General Description Guide for more detai
92. et power cords and CIC cables and repeat the test If the LEDs on the MCP MCP2 still do not illuminate unplug the system remove the power supply and check the AC fuse located on the bottom see Figure 4 1 If the fuse is good but the LEDs do not illuminate you must correct the problem before continuing Turn off the power switch Unplug all cards using the card ejectors Turn the system on Check the LEDs again If the problem is corrected you have a defective card Test and remove the faulty card before continuing If the LEDs still do not light unplug the cabinet and change power supplies This will probably solve the problem If it does not contact SAMSUNG Technical Support If the LEDs on a LCP LCP2 card do not light unplug and replace the CIC cable If this does not cure the problem unplug and replace the LCP card If the LED still does not light unplug the system remove the expansion cabinet power supply and check the AC fuse located on the bottom see Figure 4 1 If the fuse is good but the LED does not illuminate you must correct the problem before continuing Turn off the power switch Unplug all cards using the card ejectors Turn the system on Check the LEDs again If the problem is corrected you have a defective card Test and remove the faulty card before continuing If the LEDs still do not light unplug the expansion cabinet and change power supplies This will probably solve the problem If it does not contact SAMSUNG Tech
93. f the VPMs installed SAMSUNG Electronics Co Ltd Page 11 1 CHAPTER 11 SVMi 8 Set Up OfficeServ 500 Installation Guide Ed 01 2 INSTALLATION OF THE SVMi 8 Follow the steps below to ensure that the SVMi 8 is properly setup 1 2 3 4 5 6 Page 11 2 INSPECTION Unpack and inspect the unit for obvious damage This card should be labeled SVMi 8 If it is not you have the wrong card INSERTING THE CARD Check that the DCS power switch is the OFF position The SVMi 8 card is installed in any universal slot of any cabinet Next position the SVMi 8 card in the grooves of the card guide and gently slide the card in until it makes contact with the connector Press gently but firmly on the top and bottom of the front edge of the card until the card sits in its connector POWER UP Complete installation of all other required iDCS interface cards and turn the iDCS power switch ON CONFIRM OPERATION Wait for the ACT LED to be either OFF or ON steady green Either of these conditions indicates normal operation as defined in the table above iDCS PROGRAMMING Perform the following iDCS programming steps A through F It is necessary to perform these at this time so that the SVMi 8 will read these MMCs and initialize accordingly MMC 601 All SVMi 8 ports must be assigned to SVMi 8 group By default this will be the last available group on the system 529 or 5029 OfficeServ 500 M and 549 or 5049 OfficeServ 500 L and wil
94. fficeServ 500 system choose a site that meets the following requirements Select a location for the OfficeServ 500 system that has enough space for easy installation and adequate lighting see Figure 1 1 566 93mm 299 97mm gt e 501 90mm 1505 70mm 1003 80mm FF Figure 1 1 Key Service Unit Dimensions O SAMSUNG Electronics Co Ltd Ha C SES Men ES o o 65mm Ce RI Page 1 1 CHAPTER 1 Site Requirements OfficeServ 500 Installation Guide Ed 01 Page 1 2 e Select a location that will minimize cable lengths See the Cable Requirements Table in the OfficeServ 500 General Description Guide The equipment should not be exposed to direct sunlight corrosive fumes dust constant vibration or strong magnetic fields such as those generated by motors and copy machines Adirect commercial AC power outlet is required Do not use extension cords Preferably a dedicated circuit should be used to minimize the risk of other electrical equipment being connected that could adversely affect system operation e Ensure that all wires and cables going to and coming from the OfficeServ 500 are properly routed Do not cross fluorescent lights or run parallel with AC wires e The equipment must be located in an environment that will maintain a temperature range of 32 77 F 0 25 C and a humidity range of 10 90 non condensing
95. forwarding function If a call is received from the trunk the Trunk Forward option in Program 400 shall be set to On To forward every incoming call to a station of another system the CFU option in Program 823 shall be set to Y To forward an incoming call of a busy station to a station of another system the CFB option in Program 823 shall be set to Y To forward a call to a station of another system when the call is not answered during the set time the CFNR option in Program 823 shall be set to Y Call Offer In case the counter party is busy or not answering when the station of another system is called the Camp On function is required just like a calling in the same system The Call Offer option in Program 823 shall be set to Y If the Path Retention option in Program 823 is set to Y the station will be automatically camped on Call Intrusion When the call receiving party in another system is busy the barge in or override function is required just like a call in the same system The following options shall be set The same program needed for barging in or overriding is also required The Barge In Type option in Program 206 shall be set to With Tone or Without Tone and the Override option in Program 701 to Yes the Secure option to No To barge in or override the station call of another system the CI option of P
96. hapter 6 MDF STATION CONNECTIONS TO BRI CARD PAIR FUNCTION CIRCUIT PIN Tx1 TIP 26 Tx1 RING 1 1 Rx1 TIP 27 Rx1 RING 3 2 28 3 Tx2 TIP S 29 CABLE TO BRI Tx2 RING 4 EQUIPTMENT Rx2 TIP 30 Rx2 RING S 5 31 6 Tx3 TIP 32 Tx3 RING i 7 CUSTOMER Rx3 TIP 33 PROVIDED 3 BRI Rx3 RING 8 EQUIPMENT 34 9 Tx4 TIP 35 Tx4 RING i 10 Rx4 TIP 36 Rx4 RING i 11 37 12 Figure 5 6A MDF Trunk Connections SAMSUNG Electronics Co Ltd Page 5 7 CHAPTER 5 Connecting Trunk Line Circuits Page 5 8 MDF TRUNK CONNECTIONS TO BRI CARD OfficeServ 500 Installation Guide Ed 01 PAIR CABLE TO NT1 Figure 5 6B MDF Station Connections FUNCTION CIRCUIT PIN Tx TIP 26 Tx RING i 1 RCV TIP 27 RCV RING i 2 28 3 Tx TIP 29 Tx RING 4 RCV TIP 30 RCV RING S 5 31 6 Tx TIP 32 Tx RING S 7 RCV TIP 33 RCV RING S E 34 9 Tx TIP 35 Tx RING s 10 RCV TIP ni 36 RCV RING 11 37 12 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 5 Connecting Trunk Line Circuits 7 ISDN PRI LINES PRI or TEPRI cards supports a RJ 45 connector to access ISDN PRI lines from trunk line Connect the PRI port with given line cord as shown in Figure 5 5 8 8BSI CARD The 8BSI Base Station Interface card must be inserted in slots 1 2 or 3 of same cabinet If multiple 8BSI cards are installed in an OfficeServ 50
97. he SCP card The uses are as follows Tx SCP HDLC Tx Transmit Status OFF indicates that there is no link from the SCP card ON indicates that the link from the SCP card is being set up Flicker indicates a message has been transmitted Rx SCP HDLC Rx Receive Status OFF indicates that there is no link from the SCP card ON indicates that the link from the SCP card is being set up Flicker indicates a message has been received SCP SCP Processor Status OFF indicates that Power is OFF ON indicates that the SCP is booting Flicker indicates normal operation S1 S8 Card Status OFF indicates that the card is idle or not installed ON indicates one or more circuits busy Flicker indicates the card has a fault or is inserted in the wrong slots e g TEPRI PRI BRI card must be inserted in the slot 1 or 2 or 3 otherwise LED flickers S9 Not Used SAMSUNG Electronics Co Ltd Page 3 9 CHAPTER 3 Installing Printed Circuit Cards OfficeServ 500 Installation Guide Ed 01 4 Page 3 10 SCP2 CARD When the system is configured as the OfficeServ 500 L system the SCP2 card controls the operation of the basic cabinet and exchanges messages with the MCP2 card through a high speed data link The SCP2 card is mounted in the Slot9 SCP slot of the OfficeServ 500 L basic cabinet Only the internal memory differs in hardware between the SCP and SCP2 The internal DRAM memory of SCP is 2 MB while the internal DRA
98. he connection of hardware through the LAN port between the OfficeServ 500 system and the programming PC for the MCP card is configured as shown below LAN Port wea y OfficeServ 500 s Prgramming PC Figure 7 7 Programming PC connection through LAN port for MCP card The connection of hardware through the LAN port between the OfficeServ 500 system and the programming PC for the MCP2 card is configured as shown below Prgramming PC OfficeServ 500 Figure 7 8 Programming PC connection through LAN port for MCP2 card To program the OfficeServ 500 via a IOM serial port use an RS232C cable with connections shown in Figure 7 6 When the PC needs to be more than 5 metres away from the KSU use shielded computer cable Attach a male DB9 connector to the SIO end and one that meets the requirements of the PC to the other end This cable must not exceed 10 metres Use MMC 804 to set the transmission parameters for the serial port SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide
99. hen centralized voice mail is used with the SVMi 4 8 16 card a mail box used by the stations of another system shall be created manually one by one If the option for this is set to Y up to 100 phone numbers starting with the number specified in Program 724 and consisting of numbers corresponding to SZ will be created to make a voice mail automatically That is 100 voice mails with the numbers 2200 2299 are created automatically Use this option carefully because the maximum number of voice mails for the SVMi card is limited 2 3 Route Incoming and Outgoing 2 3 1 Route Incoming 1 Program 427 Set PRI Option If the TEPRI card is used for PRI networking options shall be set for each card Each field of the program is described below Channel Any Selects free channels to make a call to the PRI card when Y is selected If you want to use networking functions especially call back it is recommended that N is selected PRI Mode If DDI is specified the call is connected according to Program 714 The networking functions of the OfficeServ 500 system are based on DDI mode Therefore the functions shall be always used in DDI mode DLSEND If ENBLOCK is specified the system will assign trunk line and make a call unless you dial and presses or you dial again until ISDN Inter Digit Time from Program 501 passes The networking functions of the OfficeServ 500 system are based on EN
100. igure 5 4 MDF Connections Off Premise Extension from SLI Card O SAMSUNG Electronics Co Ltd Page 5 5 CHAPTER 5 Connecting Trunk Line Circuits OfficeServ 500 Installation Guide Ed 01 5 E1 PRI CIRCUIT El and PRI connection is provided via the RJ 45 socket marked T1 on the TEPRI card Connect the system and the network terminating point NT1 using an 8 conductor UTP CAT 5 cable Where possible the system should be located within 5 metres of the Network Terminating point NOTE Y 00 poa e PD LS A mn Edd A VU RECEIVE TWISTED PAIR MALE RJ 45 ENCED CABLE SYN OO LOS M5 DO 12 PC OO CLK m oo TP2 TELCO El or PRI CIRCUIT Figure 5 5 MDF Connections E1 PRI Circuit to TEPRI Card Page 5 6 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 5 Connecting Trunk Line Circuits 6 ISDN BRI LINES The BRI card can be used to provide direct connection to the Network Terminating point NT1 for ISDN trunks default mode or ISDN terminal equipment TE for ISDN Stations Connect each port of the BRI card required for use as an ISDN trunk to a separate to NT1 share with other terminal equipment In this case the 100 ohm terminating resistors ei When connecting the BRI port to the NT1 care is needed if the BRI circuit is being on the BRI card ports may need to be switched out of the circuit For ISDN station interface connection details to ISDN TE see over and C
101. in until it makes contact with the connector Press gently but firmly on the top and bottom of the front edge of the card until the card sits in its connector Ensure that you have installed the correct power supply Power Rregulator RSI E Se V M Voice i Y Processing 8 i Module O El Ports 5 8 a L Serial Port fe 1 die Es A Lo El Voice eg Processing x ou e Backplane SE Connector Parallel Port J Su I HDD Access o RUN Indicator O 5 Reset Button RST y Disk Drive LI Figure 3 22 SVMi 8 Card Now go to Chapter 11 SVMi 8 Set Up of this guide Do not insert this card with system power ON Page 3 38 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 3 Installing Printed Circuit Cards 33 SVMi 16 CARD Unlike the previous voice mails and automatic relay systems based on PC SVMi 16 is installed inside the telephone equipment and is operated as a part of the telephone system One card shall be used per system and the mounting location is not limited The components of SVMi 16 are shown below Figure 3 22 SVMi 16 Card SBC SVMi 16 Mother Board SBC means a Single Board Computer and is the main circuit card connected to the OfficeServ 500 system The disk drive and voice process
102. k INTRODUCTION Purpose OfficeServ 500 Enterprise IP Solutions System is a digital telephone system designed for small to medium sized businesses This guide provides the information about installation of the SAMSUNG OfficeServ 500 including information about connecting the equipment When there are questions about OfficeServ 500 system or damage to the phone please call your Authorised Samsung Reseller Document Content and Organization This guide consists of following 12 chapters Find and read necessary chapters Site Requirements e Installing Single Multiple Cabinet Configurations e Installing Printed Circuit Cards e Power Up Procedures e Connecting Trunk Line Circuits e Connecting Station Equipment e Connecting Optional Equipment Installing KDB Keyset Daughter Boards Software and Database Management e Adding Cards to the System e SVMIi 8 Set Up e Networking Description and Programming Procedure SAMSUNG Electronics Co Ltd Page Introduction OfficeServ 500 Installation Guide Ed 01 Conventions The following special paragraphs are used in this document to point out information that must be read This information may be set off from the surrounding text but is always preceded by a bold title in capital letters The three categories of these special paragraphs are WARNING Indicate a potentially hazardous situation which if not avoided could result in death or WARNING serious injury
103. l automatically be set as Bi VMS GRP when the system recognises the card MMC 601 Select either SEQUENTIAL or DISTRIBUTED ring mode MMC 207 If you are using SVMi 8 for Auto Attendant use MMC 406 to set the desired trunk s to ring group 529 If you are using SVMi 8 for Voice Mail make sure that all desired stations are forwarded to group 529 MMC 406 For Auto Attendant use set the desired trunks to ring SVMi 8 group MMC 102 For Voicemail use make sure all desired stations are programmed to forward to the SVMi 8 group MMC 714 Used to set DID numbers to ring the SVM1 8 group directly MMC 751 Select NO for each station that you DO NOT want to create a mailbox for INITIALIZE SVMi 8 Press the red RST button to read these MMCs and initialize SVMi 8 accordingly SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 11 SVMi 8 Set Up 3 TESTING THE HARDWARE 1 Call each SVMi 8 port individually and confirm that SVMi 8 answers 2 Call group the SVMi 8 group and confirm that SVMi 8 answers If steps 1 and 2 above proved to be successful you have completed the installation and setup of the SVMi 8 hardware You are now ready to begin programming the SVMi 8 Voice Mail Auto Attendant system parameters MMC 750 After programming set Download to NO to ensure that the next time the SVMi 8 reset button or the system is powered OFF and then ON that the programming on the SVMi 8 is not lost 4 R
104. l flicker 100 msec ON OFF At the end of the ITM3 card initialization the slot LED will turn off The ITM3 card has a recessed RESET button that will initialize the ITM3 card manually if required The RS232 DB 9 connector on the face of the ITM3 card allows trace monitoring of the ITM3 functions This is used for testing purposes and only to be used under the supervision of SAMSUNG Technical Support The operation of the ITM3 card LEDs is described below There are no switches or jumpers on the ITM3 card which require setting LED Name Function PWR This LED is ON when 3 3 volts power is applied to ITM3 Card Swi This LED is ON when S W task for H323 stack is operates Tx This LED is ON when Tx data is valid on only 100M Ethernet port So it is OFF to be connected to 10M Ethernet port Rx This LED is ON when Rx data is valid on both 10M and 100M Ethernet port RUN This LED is connected the address Bus 8 pin of CPU So it is ON when CPU is running The faster CPU operates the brighter LED is SW2 This LED indicates a processing state for voice packeting in Call SW3 This LED is ON when call service is ready SW4 This LED is flicker at a low rate to indicate O S task in Software running SAMSUNG Electronics Co Ltd Page 3 43 CHAPTER 3 Installing Printed Circuit Cards Page 3 44 EE E PWR OO RUN swi QQ sw2 TX OO Sw3 sw4 LAN 355 DO HS SC a
105. l is automatically converted to a station call at a certain time Aspects such as efficiency functionality and call sensitivity of the trunk line connecting systems were considered Centralized Operator This function enables you to conveniently call the attendant of another system as if calling that of the same system enabling you to operate only one attendant in the network However the attendant using CTI is not applicable Caller ID Transfer This function enables you to send the received Caller ID CID when transferring or forwarding the received trunk line call to the station of another system SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 12 Networking Description and Programming Procedure 1 3 Provide Q SIG Additional Function Networking of the OfficeServ 500 system provides Q SIG additional functions as follows 1 2 3 4 5 6 7 8 9 Call Transfer and Transfer Recall by Join This function enables you to transfer the busy call to a station of another system as 1f transferring calls within a same system When the transferred call is not answered within the defined time the call is transferred back to the original caller Name Identification When calls to stations of another system are dialled or connected the name and phone number of each party can be transferred according to the options Call Forwarding Unconditional CFU This function enables you to f
106. led if all required daughter boards have been installed Figure 3 13 MFM Board Only one MFM board can be installed on each processor card A MFM card cannot be e installed onto a processor card with an SCM card installed Page 3 20 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 3 Installing Printed Circuit Cards 13 RCM BOARD This board has a selectable option for CID or R2MFC If the system has more than one cabinet the RCM board must be installed in position LOC3 of the MCP MCP2 card any available position of the SCP SCP2 card see Figure 3 3 or any available position of the LCP LCP2 cards Up to 3 RCM boards can be installed in a system one on the MCP MCP2 or SCP SCP2 and one on each LCP LCP2 The RCM board is used to provide 14 Caller ID DSP circuits Caller ID detection on loop start trunks 8TRK To install the RCM board remove the two 2 screws holding the MCP MCP2 or LCP LCP2 protective casing together see Figure 3 6 or remove the 4 screws holding the SCP SCP2 case together see Figure 3 10 and separate the two halves of the case Place the RCM board face down over the two connectors taking care to properly line them up and press gently on the back of the board to seat it The MCP MCP2 LCP LCP2 SCP SCP2 case can now be reassembled if all required daughter boards have been installed U2 z CE T
107. line Group MCP MCP2 800 Set PRI of TEPRI connected with System A through Networking 803 Set VoIP Networking Signaling trunk line SAMSUNG Electronics Co Ltd Page 12 19 CHAPTER 12 Networking Description and Programming Procedure OfficeServ 500 Installation Guide Ed 01 Program 710 Enter a Digit for Auto Route Selection MCP MCP2 Index Digit Length LCRT 0001 00 12 3 gt International call Sends to the system A 0002 01 10 3 Mobile call Sends to the system A 0003 02 9 3 Long distance call Sends to the system A 0004 03 10 3 gt Local call Sends to the system A 0005 04 10 3 0006 05 10 3 0007 06 10 3 0008 07 10 3 gt 070 call Sends to the system A 0009 08 10 3 gt 080 call Sends to the system A 0010 091 7 1 gt The station call of the system A 0011 093 7 1 gt The station call of the system C Sends to the system A 0012 094 7 2 gt The station call of the system D 0013 1 3 3 gt Special call Sends to the system A 0014 2 7 3 gt Local call Sends to the system A 0015 3 7 3 0016 4 7 3 Index Digit Length LCRT 0017 5 7 3 0018 6 7 3 0019 7 7 3 0020 8 7 3 0021 9 7 3 Program 712 Enter the Route Table for Auto Route Selection MCP MCP2 Page 12 20 Table Time Class Route Modify 01 1 1 803 2 800 02 1 1 803 gt Sends to the system A for outgoing through trunk 03 1 1 803 001 line 2 800 001
108. ls 2 Do not connect devices with a total REN greater than 5 0 to this card Except for Australia Australia use an external ringer 3 Ringer Frequency External Ringer 20 Hz 80 Vrms SINUSOIDAL WAVE For Australia and Italy Internal Ringer 25 Hz 80 V RECTANGULAR WAVE For the other countries in Europe 4 This card does not contain OPX over voltage protection circuitry 5 The message waiting circuitry only illuminates the message lamp when the station is idle Therefore a 16SLI card and the 16MWSLI card follow the same configuration rules when considering a single or double power Supply 6 SLI port feed voltage is nominally 25 VDC SAMSUNG Electronics Co Ltd Page 3 33 CHAPTER 3 Installing Printed Circuit Cards OfficeServ 500 Installation Guide Ed 01 30 TEPRI CARD The TEPRI card installs in slots 1 2 or 3 of any cabinet The OfficeServ 500 TEPRI supports either El or ISDN PRI service The first four LEDs on the front of the card provide the status of the service Sync AIS Loss and Layer 2 Active states The second four LED s on the front of the card display the type of service The first TEPRI card installed in the OfficeServ 500 is the primary source of external clocking The second TEPRI installed is the secondary source of external clocking Clock selection is first cabinet left to right then second cabinet left to right The primary and secondary clock sources should be mounted in the bottom ca
109. m 615 Program 824 Convert Auto Route Selection Expansion Dial The networking dial number is entered in Program 724 for this program If index 01 from the networking dial number of Program 724 is set to 22 a will be displayed Enter the following to convert the number to node number amp station number 01 22 gt 01 22 gt 09122 SZ 0 MAX 00 MB N SZ 4 MAX 07 MB N SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 12 Networking Description and Programming Procedure Each field from b is described below e 01 Index differentiated from the networking dial number of Program 724 22 Number specified from the networking dial number of Program 724 e 09122 Specifies node number 091 station number 22 This means that a station number 2200 to 2299 is dialled in the system with a node number 091 The added node number shall be specified to DIGIT from Program 710 e SZ 4 This means that you presse a 4 digit number when you dial a station starting with 22 in the system with a node number 091 MAX 07 Total number of digits which have been converted to node number station number This is very important to the ENBLOCK dial which shall information on counterpart when a call is set When 7 digit numbers are entered the system assigns a trunk line and transmits a call by using the auto route selection function without waiting for your pressing e MB N W
110. m the LCP card is being set up Flicker indicates a message has been received S7 LCP C 3 HDLC Tx Transmit Status OFF indicates that there is no link from the LCP card ON indicates that the link from the LCP card is being set up Flicker indicates a message has been transmitted S8 Not used 9 Not used There are several daughter boards that can mount on the MCP see Figure 3 1 The daughter boards have offset pin connectors which prohibits improper installation of the Daughter board s Depending on the installation requirements the daughter boards provide the following MISC 2 External music audio inputs 1 external page audio output 1 Loud bell relay contact closures 2 page relay 1 common bell OfficeServ 500 M only e SCM 18 Conference channels 12 DTMF receivers OfficeServ 500 M only MFM 12 DTMF receivers OfficeServ 500 M only RCM 14 CID receivers and 8 R2 Receivers OfficeServ 500 M only e IPM Motorola MC 68302 25Mhz processor for message handling 1 5 Mbyte SRAM 4 Megabytes DRAM 3 synchronous communication ports for inter processor communications This board is required for multiple cabinet systems LAN 10BASE T LAN Interface 0 5 Megabytes of SRAM 2 Serial I O circuits e ESM Increases the system to 1024 channel time switch This board is required for multiple cabinet systems MAIN CONTROL PROCESSOR MCP DAUGHTER BOARD CAPABILITIES Position Types of Daughter Board
111. n be used by connecting to the OfficeServ 500 system OfficeServ 500 Wireless LAN Service Manual Introduces information needed to install the wireless device of the OfficeServ 500 system or for its maintenance WIP 5000M Phone User Guide This is a user s manual for WIP 5000M that is designed to use wireless LAN provided from the OfficeServ 500 system The manuals for OfficeServ 500 Wireless LAN and WIP 5000M Phone will be provided at the time of product release in later time Revision History EDITION DATE OF ISSUE REMARKS 00 07 2003 First Edition SAMSUNG Electronics Co Ltd Page Ill Introduction OfficeServ 500 Installation Guide Ed 01 y This page is intentionally left blank Page IV SAMSUNG Electronics Co Ltd SAFETY CONCERNS For product safety and correct operation the following information must be given to the operator user and shall be read before the installation and operation Symbols Caution Indication of a general caution Restriction Indication for prohibiting an action for a product Instruction Indication for commanding a specifically required action SAMSUNG Electronics Co Ltd Page V Safety Concerns OfficeServ 500 Installation Guide Ed 01 WARNING Never install telephone wiring during a lightning storm There may be a remote risk of electric shock from lightning Never install telephone jacks in a wet location Unles
112. n the 18 or 28 button phone The FKDBD will provide one additional DLI circuit for the connection of any digital station device such as a phone add on module or DPIM This FKDBD will only operate when the phone is connected to an 8 port DLI card so it can use the second B channel Each port on this card is intended for connection to one telephone Connecting multiple telephones to a port may result in incorrect operation or damage to the card 2 iDCS KDB SINGLE LINE INTERFACE FKDBS This is a daughter board that can be installed only in the 18 or 28 button phone The FKDBS will provide one additional SLI circuit for the connection of any standard telephone device This FKDBS will only operate when the phone is connected to an 8 port DLI card it can use the second B channel Each port on this card is intended for connection to one telephone Connecting multiple telephones to a port may result in incorrect operation or damage to the card The circuitry on a FKDBS does not provide a loop open disconnect signal or have the over voltage protection necessary for OPX operation 3 iDCS KDB FULL DUPLEX FKDBF The standard speakerphone mode of operation for an iDCS phone is half duplex This means that you cannot transmit and receive speech at the same time Adding a FKDBF to your phone will convert the speakerphone into full duplex mode enhancing its operation In addition the FKDBF may have up to 3 external microphones attached t
113. nical Support SAMSUNG Electronics Co Ltd A OfficeServ 500 Installation Guide Ed 01 CHAPTER 4 Power Up Procedures PROCESSOR CARD INDICATIONS After verifying proper operation of the power supply visually check the processor card indications The MP LED on the MCP MCP2 should flicker rapidly indicating the main processor is functioning and the SM LED should be on steady indicating that the SmartMedia card is present and recognized The HDLC LEDs on the SCP SCP2 and LCP LCP2 should be flickering and the processing LED on the LCPs should be steady CARD VERIFICATION Before connecting all MDF cabling plug in a test cable to the first DLI card Connect a phone and verify that it is working Use maintenance program MMC 727 to verify the system and software versions and to confirm that all cards are recognized by the MCP MCP2 Remove the test cable and plug in all amphenol type cables to the MDF At this time it is recommended that the system be defaulted using MMC 811 See the Programming Guide for more details Proceed with the rest of the installation DEFAULT TRUNK AND STATION NUMBERING Upon initial power up the MCP MCP2 reads each slot for the existence of a card and identifies the type of card It stores this information as the default configuration The trunk card in the lowest slot number is assigned trunk numbers beginning with 701 The next highest slot number with a trunk card is assigned trunk numbers following those
114. normally operating Rx Light green Displays reception of data through Ethernet Blink Data is being received Off Data is not being received Tx Light green Displays transmission of data through Ethernet Blink Data is being transmitted Off Data is not being transmitted SRV Light green Displays if service is possible On Service is possible Blink Program is being modified or configuration is being downloaded Off Service is not possible DSP Light green Displays if the DSP channel is being used Off All channels are not in use Blink 400ms 1 to 7 channels are in use Blink 200ms 8 to 11 channels are in use Blink 100ms 12 to 15 channels are in use On All voice channels 16 channels are in use IPC Light green Displays the IPC status between the MGI card and the system Blink IPC is in normal status Off IPC is not in normal status LAN Connection Port Page 3 48 MOD Light green Displays the operation status of the MGI card OFF The card is normally booted and is operating normally ON The card is not normally booted The RJ 45 connector for LAN port connection is located at the front panel of the MGI card The LAN port is connected to the Internet network through the network equipment such as the switching hub RS232C Connection Port This port is connected to the PC and is used when execu
115. nstaataxnaalactaatascnavasinsdsrouses 3 24 GIRKi CARD visa A NS 3 25 AN alia 3 25 PRICARD near er ditendenns nant nden eege geet 3 26 SBSICARD E 3 27 4E amp M CARD iii aria iena iena REENEN EEN EEN deeg 3 27 DLUIGARD s tenia A ia 3 28 MODEL CARD E 3 28 SEV CARD EE 3 29 BSEU CARD E 3 30 SAMSUNG Electronics Co Ltd Page IX Table Of Contents OfficeServ 500 Installation Guide Ed 01 26 27 28 29 30 31 32 33 34 35 36 37 38 A E T EREA EE A TT 3 31 BRI SOTO CARD ee EEN 3 31 8MWSLI CARD 2e dia E T EE 3 32 16MWSLICARD SEENEN EE 3 33 TEPRE CARD a lella 3 34 30 1 TEPRI Card DIP Switch nee 3 35 30 2 TEPRI LED Definitions paia 3 35 AUTO ATTENDANT CARD viii iii 3 37 ULI iii 3 38 SVMI 16 CARD E 3 39 8WLI CARD For future application 3 42 IP TELEPHONY MODULE ITM sisi 3 43 MGR CARD EE 3 45 MGN MGI2 CARD BE 3 47 Fee Pe E E eee 3 50 CHAPTER 4 Power Up Procedures 1 DETERMINING POWER SUPPLY REQUIREMENTS errriii 4 1 1 1 OfficeServ 500 Power Supply 48 Volt Capachty nnen 4 1 1 2 Power Requirements sise 4 1 CONNECT POWER TO THE SYSTEM iii 4 5 250 PSU RUSINO clic iena ieri di 4 6 PROCESSOR CARD INDICATIONS eeennnennnnnnennnts 4 7 CARD VERIFIGATION cc Eege 4 7 DEFAULT TRUNK AND STATION NUMBERING ses 4 7 CHAPTER 5 Connecting Trunk Line Circuits O a WO N Page X SAFETY PRECAUTIONS
116. nting up to 2000 digits DIGIT The forepart of the digit sent through the trunk line using auto route selection The route can be easily defined by using the node number since the node number is required for calling systems connected by network Note that the digits including the additional node numbers set in Program 824 shall be assigned to dial other systems conveniently LENGTH The system selects and sends the entered digit through the trunk line when digits of this length are entered RT The route table of Program 712 which is set according to the entered digit Program 711 Auto Route Selection Time Four time zones are assigned for each weekday when using auto route selection Fields of the program are described below SUN SAT Displays weekdays from Sunday to Saturday A D Displays the four time zones Enter all 24 hours into time zone A since cost differences between service providers are seldom inversed in Korea e g A 0000 B 2359 HHMM Enters the hours and minutes in the 24 hour mode LCRT Sets the number of the time table used in Program 712 Set all numbers as 1 for Korea Program 712 Auto Route Selection Route This program allows you to set the routing table for trunk line selection when using the Auto Route Selection feature Fields of the program are described below SAMSUNG Electronics Co Ltd Page 12 9 CHAPTER 12 Networking Description and Programming Procedure OfficeServ 500 Installation G
117. o install four voice port VPMs or Fax VPMs Main Memory The main memory of the SVMi 16 card is a 32 Bit size CPU dedicated memory Compact Flash Memory or Hard Disk This device is used to store all messages and greetings as well as the main system programs The amount of time stored in the hard disk is determined by the size of the drive which is measured in Megabytes Mbytes This memory unit consists the hard disk The current size of this memory is approximately 100 hours Memory for SVMi 16 is only available at SAMSUNG The hard disk drive can be removed or replaced when problem occurs or during upgrade and is fixed to SBC with four screws The hard disk drive is connected to SBC by a ribbon cable The connector on the hard drive has four auxiliary pins which are not used Voice Processing Module VPM Each VPM has four channels This means that four callers can connect to each VPM installed at the same time VPM is attached to SBC by the end side connector Each SVMi 16 has 8 channels without VPM The SVMi 16 card can install two of such cards and process up to 16 calls simultaneously The 4 port voice processing module is a small and detachable hardware board that is called VPM This is connected to the SVMi 16 motherboard The available number of ports can be increased from 8 to 16 when this is installed on the SVMi 16 card The SVMi 16 card cannot be expanded over 16 ports SAMSUNG Electronics Co Ltd OfficeServ 500 In
118. o it for conference room type applications These microphones require an EXTMIC key programmed on the phone to activate or deactivate them SAMSUNG Electronics Co Ltd Page 8 1 4 Page 8 2 CHAPTER 8 Installing Keyset Daughter Boards OfficeServ 500 Installation Guide Ed 01 KDB DLI This daughter board can be installed only in the DCS 12 or DCS 24 button phone Before performing this procedure unplug the line cord from the phone and remove the base wedge Place the phone face down on a soft surface and remove the four base retaining screws Separate the base from the phone and place the phone aside Attach the KDB DLI to the phone base with the four screws that are supplied Take care to ensure that the modular socket shows through the access hole in the base invert the base assembly over the phone and plug the ribbon cable into the socket on the phone PCB while making sure that no damage occurs to the phone PCB Reattach the base to the phone and test to ensure normal phone operation KDB SLI This daughter board can be installed only in the DCS 12 or DCS 24 button phone Before performing this procedure unplug the line cord from the phone and remove the base wedge Place the phone face down on a soft surface and remove the four base retaining screws Separate the base from the phone and place the phone aside Attach the KDB SLI to the phone base with the six screws that are supplied Take care to ensure that the modular socke
119. of the first trunk card This numbering sequence continues until the last trunk card in the highest slot number is assigned the last trunk number For example if an 8TRK card is in the first slot port C1 S1 P1 is assigned trunk number 701 first cabinet first slot first trunk in the system If the second slot has a Trunk B card installed port C1 S2 P4 is assigned trunk number 712 first cabinet second slot fourth circuit twelve trunk in the system Station numbers are assigned in the same manner The lowest slot number containing any type of station card is assigned station numbers beginning with 201 The next highest slot with a station card is assigned numbers following those of the first station card This numbering sequence continues until all of the stations are assigned Default data assigns the 24 button phone in the lowest port to the operator group and all trunks ring that station until the default is changed It is recommended that the first station card be a DLI card so that the operator station will default to a phone as extension 201 Using MMC 724 station and trunk numbers can be changed rearranged and reassigned as needed SAMSUNG Electronics Co Ltd Page 4 7 CHAPTER 4 Power Up Procedures OfficeServ 500 Installation Guide Ed 01 Newly added station or trunk cards come up without directory numbers The above a examples describe a system using a three digit numbering scheme If the DIP switches on the MCP are change
120. oming calls can be assigned to ring over page Program the line or lines to ring a hunt group Using MMC 601 assign ROP as a destination in this hunt group Ring over page can be used for day or night operation or both SAMSUNG Electronics Co Ltd Page 7 3 CHAPTER 7 Connecting Optional Equipment OfficeServ 500 Installation Guide Ed 01 5 Page 7 4 SMDR AAUCD TRAFFIC ALARMS To receive SMDR Station Message Detail Recording AAUCD statistics traffic or alarm reports connect a customer provided printer or PC to one of the four RS232C DB9 connectors on the main cabinet see Figure 7 4 Use a pin to pin RS232C cable See Figure 7 5 and Figure 7 6 for the required pins When the printer or optional call accounting device needs to be more than 5 metres away from the OfficeServ 500 use shielded computer cable Connect the customer provided equipment to the serial interface port selected Attach a male DB9 connector to the serial port The other end must meet the requirements of the device or printer Use MMC 725 to set SMDR print options and use MMC 804 to set the port and transmission parameters MMC 804 also selects the required report s Select one of the ports from SIO1 to SIO4 for the system I O port when using the MCP card and select one from SIO3 to SIO4 when using the MCP2 card LAN Board SIO Ports MCP SIO Ports Pa st fi i Le S101 EES S103 SIO4 LAN PWR T BATT o
121. on Restriction CLIR N Calling Name Identification Presentation CNIP Y Calling Name Identification Restriction CNIR N Calling Name Identification Restriction Override CNIRO Y Connected Line Identification Presentation COLP Y Connected Line Identification Restriction COLR N Connected Name Identification Presentation CONP Y Connected Name Identification Restriction CONR N Connected Name Identification Restriction Override CONRO Y In Q SIG there are cases when only the name not the number is sent to the system Since the OfficeServ 500 networking function is supposed for connections between iDCS systems if the Add Number To Name option in Program 825 is set as Yes the name is sent with the number suffixed and the recipient also checks of the number is suffixed to the name Automatically Convert trunk line Calls to Station Calls Route Optimization When a call is made to another system but is connected to the station within the same system due to transfer or forward call the trunk line call is automatically converted to a station call at the Route Optimize Time of Program 501 This program operates normally only when the PATH REPL option of Program 823 is set as Y when station numbers of all systems do not overlap and when the auto route selection feature is being used The system timer of the finally connected call operates at the Route Optimize Time of Program 501 Single A
122. onductor The earth wire between the cabinets can also be connected using the grounding bar in each cabinet A separate earth wire must be run from the main cabinet to each expansion cabinet SAMSUNG Electronics Co Ltd Page 2 9 CHAPTER 2 Installing Single Multiple Cabinet Configurations OfficeServ 500 Installation Guide Ed 01 When a permanent bonded earth is used the earth conductor in the power supply cord MUST be disconnected from the system This can be achieved by 1 Removing the main cabinet back cover See WARNING above 2 Removingthe screw securing the earth wires to the cabinet in the top right hand side of the main cabinet 3 Disconnect the green yellow earth wire coming from the mains cable only The second green yellow sheathed earth wire connected to the OfficeServ 500 backplane MUST be reconnected 4 Secure the green yellow sheathed earth wire to the cabinet using the screw removed in 2 above Failure to provide an adequate ground may cause a safety hazard confusing trouble symptoms or even circuit card failure Remove Amp Champ connectors from trunk cards and unplug the power cord from the AC outlet before attempting to connect the alternative ground Hazardous voltage may cause death or injury Observe extreme caution when working with AC power WARNING The reason for the above paragraphs is that when conventional analog telephone circuits are connected to the OfficeServ 500 system under fault
123. operation of the OfficeServ 500 system MCP2 card is mounted on the MCP LCP slot of the OfficeServ 500 M or OfficeServ 500 L basic cabinet When consisting the OfficeServ 500 L system daughter boards such as IPM board and LAN board is not mounted since the MCP2 card is supported by LAN and HDLC communication with SCP2 and LCP2 unlike the MCP card ESM NUNEZ E SCM MFM RCM O RST MISC1 MISC2 E Loc3 Figure 3 3 MCP2 Card The procedures for mounting and connecting champ connectors LED indicator DIP switch MISC port memory backup switch SmartMedia and Daughter boards SCM MFM RCM MISC are identical to that of the MCP card However when the MCP2 card is mounted the LAN cable shall be connected to the RJ 45 connector at the front bottom of the MCP2 card When using the MCP card the LAN cable is connected to the RJ 45 connector at the front right side of IOM SAMSUNG Electronics Co Ltd Page 3 7 CHAPTER 3 Installing Printed Circuit Cards OfficeServ 500 Installation Guide Ed 01 MAIN CONTROL PROCESSOR MCP2 DAUGHTER BOARD CAPABILITIES Position Types of Daughter Boards allowed per position LOC1 MFM SCM RCM ESM LOC2 MFM SCM RCM LOC3 MFM SCM RCM MISC The ESM must be installed in this position in an L system VA Only one of any type of daughter board may be installed on any processor card N OTE 3 SCP CARD The OfficeServ 500 Switch Control Proces
124. orward all incoming calls to the station of another system Call Forwarding Busy CFB This function enables you to forward calls incoming when busy to the station of another system Call Forwarding No Reply CFNR This function enables you to forward calls that are not answered within a certain time to the station of another system Call Offer This function enables you to use Camp On function when the recipient of another system is busy or when there is no answer Call Intrusion This function enables you to use the Barge In function when the recipient of another system 1s busy Call Completion Busy CCBS This function enables you to use the Call Back function when the recipient of another system is busy Call Completion No Replay CCNR This function enables you to use the Call Back function when the recipient of another system does not answer O SAMSUNG Electronics Co Ltd Page 12 3 CHAPTER 12 Networking Description and Programming Procedure OfficeServ 500 Installation Guide Ed 01 10 DND and DND Override DND and DND Override When a call from another system is connected to the station set as DND the receiving station sends a signal enabling the caller to recognize that the target station is set as DND but is not busy When you call the station set as DND the caller can override the DND setting 11 Path Replacement This function enables you to reroute the current call path when the networking call is connected 12 Centr
125. peration O SAMSUNG Electronics Co Ltd Page 12 1 CHAPTER 12 Networking Description and Programming Procedure OfficeServ 500 Installation Guide Ed 01 3 Outgoing Call This function allows you to make calls through the trunk line of another system as if making an outgoing call through that of the same system 1 2 Provide Inherent Additional Function through Q SIG The OfficeServ 500 system networking provides the inherent additional functions below by using Q SIG 1 2 3 4 5 6 7 Page 12 2 Unique Numbering Plan This function allows you to assign phone numbers with minimum programming to stations of all the systems connected through the network as to those within the same system Called Number Name Display When calling the station of another system the phone number and name of the other party are displayed as when calling that of the same system Connected Number Name Display When the station of another system is connected the phone number and name of the other party are displayed as if connected to that of the same system Call Progress Display The phone number and name of the other party is displayed in the same format as within a single system when calls to another system is transferred forwarded or reconnected after call forward Route Optimization When a call is made to another system but is connected to the station within the same system due to transfer or forward call the trunk line cal
126. ption Guide for more details 1 If a cabinet is equipped with a single power supply unit PSU B a maximum of 56 2 Do not connect devices with a total REN greater than 5 0 to this card Except for Australia Australia use an external ringer 3 Ringer Frequency External Ringer 20 Hz 80 Vrms SINUSOIDAL WAVE For Australia and Italy Internal Ringer 25 Hz 80 V RECTANGULAR WAVE For the other countries in Europe 4 This card does not contain OPX over voltage protection circuitry 5 SLI port feed voltage is nominally 25VDC BRI SOT0 CARD There are options for termination as follows ON with termination OFF without termination Insert the card into any universal slot Push firmly in the middle of both card ejectors on each card to ensure that it is fully inserted into the back plane connector VA Do not insert this card with system Power ON SAMSUNG Electronics Co Ltd Page 3 31 CHAPTER 3 Installing Printed Circuit Cards 28 OfficeServ 500 Installation Guide Ed 01 8MWSLI CARD There is an internal or external ring option on this card Insert as many 8MWSLI cards as are needed into universal slots 1 through 7 Push firmly in the middle of both card ejectors on each card to ensure that it is fully inserted into the back plane connector This card automatically detects DTMF or dial pulse signals from the SLT Software and hardware settings are not required The 8MWSLI supports
127. r supply SRV Light Displays if the voice service is available Green Blink Service is available Off Service is unavailable Tx Light Displays the status of data transmission through Ethernet Green Blink Data is being transmitted Off No data transmission Rx Light Displays the status of data reception through Ethernet Green Blink Data is being received SAMSUNG Electronics Co Ltd Off No data reception Page 3 45 CHAPTER 3 Installing Printed Circuit Cards OfficeServ 500 Installation Guide Ed 01 Page 3 46 LED Color Description Serie LED On Off Blink RUN Light Displays the operation status of the MGI3 card Green On MGI3 card is operating normally Off MGI3 card is not operating normally IPC Light Displays if messages are transferred between MGI3 card and the main Green control part Blink Messages are transferred normally Off No message transfer DSP Light Displays the usage rate of the DSP channel Green Blink DSP channel is being used Blinks every 1 second for 1 to 4 channels 0 5 second for 5 to 8 channels 0 25 second for 9 to 12 channels and 0 125 second for 13 to 15 channels On All 16 channels are being used Off No DSP channel in use MOD Light Displays if RTP data is incoming through LAN Green Blink RTP data is received normally Off No RTP data is being received SAMSUNG Electronics Co Ltd OfficeServ 500 Inst
128. rds To The System OfficeServ 500 Installation Guide Ed 01 9 Insert the smart media equipped with the program that operates on the MCP2 card into the front panel of MCP2 The booting program and the main program shall be saved in the smart media 10 Turn the system power on 11 After approximately 1 minute check if the entire system is operating Apply the required DB to the system and refer to the programming guide for the added features 2 ADDING STATIONS AND TRUNKS 1 Remove the covers of the system cabinets in order to locate a suitable empty card slot Having located a suitable slot insert the new card into the slot and push firmly in the middle of both card ejectors on the card to ensure that it is fully inserted into the back plane connector The OfficeServ 500 cabinet that the new card is to be installed in should be turned OFF prior to inserting new cards The same would apply when removing cards 2 3 Page 10 2 After the new cards are inserted the system must be told to recognize the new cards This is done through the use of MMC 806 Card Pre Install Use this MMC for each new card that is installed The new cards must be assigned directory numbers according to the system numbering plan in MMC 724 The technician must know the software port assignments of the new cards so the ports can be assigned correct numbers These software port assignments are detailed in Figure 10 1 SAMSUNG Electronics
129. re 3 15 Figure 3 16 Figure 3 17 Figure 3 18A Figure 3 18B Figure 3 19 Figure 3 20 Figure 3 21 Figure 3 22 Figure 3 23 Figure 3 24 Figure 3 25 Figure 3 26 Figure 3 27 Key Service Unit DIMENSIONS eeeeeeeeeeeeeeeeeeceeeeeeeeeaeeeeeeeeeseeeeeteneeeeees 1 1 OfficeServ 500 Wall Mounting ceeeeeeeeeeeeeneeeeeeeeeeeeaaeeseaeeeeeeaaeeneeeess 2 2 Attaching legs to main cabinet 2 3 Side Cover Mounting Brackets i 2 7 Securing Cabinet in a Rack nn 2 8 OfficeServ 500 Power Input Location 000 0 eee ee i 2 11 Reserve Power Battery Connections 2 13 Ringer Card Location sers 2 14 External Ringer Link ion Only For Australia and Italy 2 15 Connecting Champ Cables to the MDF boards 2 16 MGCP Cardit A E 3 2 MGP Location isis notin dike Bienen oa 3 6 MCP2 Gard sc Aa alii 3 7 SCP aii a 3 9 LCP Card ii cts 3 11 ER te EE 3 14 MCP MCP2 Card Screw Location nos 3 14 IPM Board sie lees age ee E Eet Ee E dn adi 3 15 LAN Do midi 3 16 MISC Boat BEER EE EEE a ia tdo o ld 3 17 Processor Card Screw Location 3 18 STOH 10l Ipo PEPEE EEATT ETETE 3 19 MEM Board addi deed EEN 3 20 RGM Baptiste Aaa iii 3 21 Modem ee WEE 3 22 IOM Board ri iaia AA ii 3 23 Cabinet Slot Numbers AAA 3 23 Interface CardS seen 3 24 PRI Cardin ressens nee entendre Ns 3 26 PERRIN dada nda dea 3 36 TEPRI Card Screw
130. rogram 823 shall be set to Y And the CI CAPABIL option number of barging in station shall be bigger than the CI PROTECT option number of barged in station If the numbers are same the call cannot be intruded Call Completion When the call receiving party in another system is busy or not answering the Call Back function can be used just like a call in the same system The following options shall be set To do Call Completion Busy Station CCBS when the call receiving party is busy the CCBS option in Program 823 shall be set to Y SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 12 Networking Description and Programming Procedure e To do Call Completion No Reply CCNR when the call receiving party of another system is not replying the CCNR option in Program 823 shall be set to Y The call completion functions operate only when the auto route selection is in use The call completion in networking uses a separate signaling channel which is different from a call path to set a call If the call completion is set the call is terminated Set the CC PATH RSV option to Yin order to maintain the already formed call path to be used when the reserved call is reset later To keep the signaling channel connected the CC SIG CONN option shall be set to Y When the reserved station becomes free and called back but the calling station is busy the
131. rth connection is essential before connecting analogue PSTN trunks These trunks must be removed then mains and battery power disconnected WARNING before the rear panel is removed for ANY reason In some circumstances the OfficeServ 500 system may require an alternative to the protective earth provided via the power cord This would be required if the protective earth provided is poor and contains noise that may prevent the digital data bus operating correctly This may result in erratic operation of the OfficeServ 500 The alternative protective earth will be required if using a UPS battery system that does not pass the ground through the power cord resulting in no ground to the system Using a UPS of this type is not recommended 7 1 Alternative Earthing Arrangements An alternative earth should also be used in the following circumstances 1 AnEl connection to the TEPRI card is required 2 An ITM3 card is to be connected to the system 3 Incases where the earth provided via the AC power cord is causing problems with the system e g due to noise In cases where an alternative earth is to be provided the grounding bar on the bottom of the left side of the cabinet must be connected to a permanent bonded earth Connection between the bonded earth terminal and the system must be via a 2 5 sq mm green yellow insulated wire Connection between cabinets in a multiple cabinet system must use a 25 amp rated earth c
132. rv 500 Installation Guide Ed 01 7 ESM BOARD This board has no selectable options and installs in position LOC1 of the MCP MCP2 card when the system has more than one cabinet installed see Figure 3 2 The ESM board is required to expand the system from 512 to 1024 time slots To install the ESM board remove the two 2 screws holding the MCP MCP2 protective casing together see Figure 3 6 and separate the two halves of the case Place the ESM board face down over the three connectors taking care to properly line them up and press gently on the back of the board to seat it The MCP MCP2 case can now be reassembled if all required daughter boards have been installed Screw III ora AN gt gt S LL TI TILT sa SO um SCORE MIRE ys Al E PONTI HERO III ui III Figure 3 6 ESM Board Figure 3 7 MCP MCP2 Card Screw Location Page 3 14 SAMSUNG Electronics Co Ltd 8 OfficeServ 500 Installation Guide Ed 01 CHAPTER 3 Installing Printed Circuit Cards IPM BOARD This board has a switch S1 for memory back up and installs in position LOC2 see Figure 3 1 of the MCP card when the system has more than one cabinet installed or the system is going to require the L version software in a single cabinet The IPM board is required to expand the system memory and to provide the message handling processor so the MCP can communicate with the SCP and LCP s
133. rve Power Battery Connections Be sure the proper polarity is observed Equipment damage will result if polarity is reversed Do not connect external AC or DC power to the System see Chapter 4 Power Up Procedures WARNING SAMSUNG Electronics Co Ltd Page 2 13 CHAPTER 2 Installing Single Multiple Cabinet Configurations OfficeServ 500 Installation Guide Ed 01 9 RINGER CARD INSTALLATION The ringer card is designed to provide ring for Single Line Telephones connected to the various Single Line Telephone SLT interface cards 8SLI 8MWSLL 16SLI and 16MWSLI installed in each cabinet in the system To minimize the use of Ringer cards it is recommended that all SLI interface cards be installed into a single cabinet Note SLI daughter cards have an onboard ringer and therefore do not used the Ringer Card to provide ring External Ringer is used in only Australia and Italy Hazardous telecommunications network voltages may be present if analogue trunks are connected Earth connection is essential before connecting analogue PSTN trunks These trunks must be removed then mains and battery power disconnected WARNING d NEES before the rear panel is removed for ANY reason 9 1 To Install Remove the 6 screws securing the back cover to the cabinet with SLT interface cards installed Remove the Ringer Card from its protective covering and position onto the 4 stand offs located at the rear of the cabinet
134. s depends on configuration of system 2 Maximum users equate to the maximum number of handsets that can be registered on the system 3 The maximum number of simultaneous calls depends on the number of DBS SAMSUNG Electronics Co Ltd connected Each DBS can support a maximum of 4 simultaneous calls Page 6 9 CHAPTER 6 Connecting Station Equipment OfficeServ 500 Installation Guide Ed 01 25 PAIR CABLE WITH FEMALE CONNECTOR TO ANY BSI CARD RJ 45 RJ 45 Connector Part Signal Connector Pin No Pin No 4 1 D Channel data 5 26 0 6 27 Sync line 3 2 D Channel data 5 29 1 12345 6 7 8 6 i 30 Sync line 3 5 4 7 D Channel data RJ 45 CONNECTOR 5 5 32 6 33 Sync line 3 8 CONNECT TO ANY PORT ON 4 10 ANY 8BSI CARD D Channel data NB POLARITY IS IMPORTANT 5 3 35 6 36 Sync line 3 11 4 13 D Channel data 5 38 4 6 39 Sync line 3 14 4 16 D Channel data 5 41 5 6 42 Sync line 3 17 4 19 D Channel data 5 44 6 6 45 Sync line 3 20 4 22 D Channel data 5 47 7 6 48 Sync line 3 23 Figure 6 5 MDF Connections RJ 45 to 8BSI Card Page 6 10 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 6 Connecting Station Equipment 8 WBS24 Wireless Base Station 2 4GHz For future Application WBS24 i
135. s use only a 48 V battery supply capable of handling a charge current of 0 45 A a charge voltage of 54 VDC and a discharge rate of 45 AH The battery source output must be fused AC 125 V 5 amp anda separate battery source must be used for each OfficeServ 500 cabinet installed Only an approved battery back up unit should be used WARNING The OfficeServ 500 provides for connection of an external battery plant e g to provide 48 VDC to power the system The PSU B PSU60 provides 56VDC at 0 4 amperes charging current e g when AC power is present which allows for float charging from the OfficeServ 500 to emergency backup batteries The OfficeServ 500 can also run without AC power on a 48VDC battery system or rectifier There should be no more than a 0 5 VDC drop in voltage from the OfficeServ 500 and the batteries Ensure polarity prior to connecting the external 48VDC power source to the system The 48 VDC cable assembly has a male 3 pin mate and lock connector on the system end see Figure 2 7 Insert this end of the DC cable into the battery BATT connector on the left hand side of the cabinet Attach the other end of the DC power cable to the 48VDC power source Page 2 12 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 2 Installing Single Multiple Cabinet Configurations CONNECT TO EITHER A OR B OPTION 8 BATTERIES SHOULD BE PLACED WITHIN THREE FEET OF KSU Figure 2 6 Rese
136. s allowed per position LOCH MFM SCM RCM and ESM LOC2 MFM SCM RCM LAN and IPM LOC3 MFM SCM RCM LAN and MISC The ESM must be installed in this position in an L system The IPM must be installed in this position in an L system eil Only one of any type of daughter board may be installed on any processor card A NOTE Page 3 4 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 3 Installing Printed Circuit Cards DIP SWITCH USE on the OfficeServ 500 MCP ON left 4 Digit Trunk Numbers 4 Digit Station Groups 4 Digit Station Numbers APD Enable Country Select Country Select Country Select Country Select OFF right 3 Digit Trunk Numbers 3 Digit Station Groups 3 Digit Station Numbers APD Disable Country Select Country Select Country Select Country Select e Switches 1 through 4 select the country the system is installed in 4 3 2 1 Country OFF OFF OFF OFF Korea OFF OFF OFF ON USA OFF OFF ON OFF UK OFF OFF ON ON Italy OFF ON OFF OFF Australia OFF ON OFF ON New Zealand OFF ON ON OFF Holland OFF ON ON ON Denmark e Switch 5 select whether APD enable or not APD Auto Program Download When it is set to ON and the version of SMARTMEDIA is not match to current system version system S W will be replaced to the S W of Smart Media e These DIP switches will not take effect unless the switches are set in th
137. s the base station equipment that enables the wireless LAN service in the OfficeServ 500 system WBS24 largely consists of the cable process part and the wireless process part There are two cable interfaces for the cable process part One is the ISDN BRI interface that is connected to the keyphone system and the other is the IEEE 802 3 Ethernet connection that is connected to the LAN network The wireless process part uses the wireless LAN RF standard of IEEE 802 11b 2 4GHz radio frequency band The ISDN BRI interface part is implemented by the National Semiconductor DASL chip Not a standard ISDN BRI and uses a independent protocol of SAMSUNG The transfer rate is 144Kbps with two voice channels and one data channel The wired section interlocking with the keyphone system supports transmission reception of voice data and transmission reception of signaling data messages for forming the voice call The cable Ethernet interface is connected to the LAN network in 10 100Base T and process transmission reception of data other than voice data such as Internet connection The wireless process part supports transmission reception of voice data for wireless voice calls and data for wireless connections such as the Internet The wireless section maximum transfer rate is 5 Mbps to 6 Mbps A single WBS24 can support 4 voice calls simultaneously and approximately 20 users can connect to the Internet simultaneously based on general Internet users The main fea
138. s the jack is specifically designed for wet locations Never touch non insulated telephone wires or terminals Unless the telephone line has been disconnected at the network interface To reduce risk of fire and jury to persons Use only a sealed nickel cadmium or lead acid battery supply capable of handling a charge Current of 0 45A a charge Voltage of 54V dc and discharge rated of 45 Ah To reduce risk of fire and jury to persons Use only the supplied line cord or other approved line cord Do not use this product Near water for example near a bath tub wash bowl kitchen sink or laundry tub in a wet basement or near a swimming pool Do not use the telephone To report a gas leak in the vicinity of the leak So oF EPP E Use only the power cord and batteries indicated in this guide Page VI SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 Safety Concerns A CAUTION Do not attempt to connect commercial AC power to the DPIM contacts When connecting a customer supplied electric door release mechanism to the DPIM an approved Line Isolation unit must be installed Do not attempt to connect commercial AC power to the MISC card When connecting a customer supplied music source to the MISC card an approved MOH Isolation unit must be installed Do not attempt to connect commercial AC power to the contacts When connecting a
139. se This will eliminate the possibility of a short on the frame causing a DSP to be assigned The four circuit SLI card 4SLI has four dedicated analog DTMF receivers One receiver is dedicated to each port on this card and only this card These analog receivers cannot be used by any other system device They are NOT a common resource The AA card has 8 DSP s that are dedicated exclusively for AA ports They can not be used for any other purpose This one DSP for each port ratio enables the AA card to NOTE answer 8 incoming calls at the same time Page 10 4 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 10 Adding Cards To The System 4 INSTALLING AA CARD IN EXISTING SYSTEM There are several things to note when installing the AA card in an existing system e The OfficeServ 500 system cabinet must be turned OFF before installing a new AA card e After installing the AA card you must perform a card preinstall as detailed in MMC 806 e After completing a card preinstall use MMC 724 to assign the AA port numbers you can use any unused numbers but the default numbers 3951 3990 will not conflict with any feature codes or station and trunk numbers SAMSUNG Electronics Co Ltd Page 10 5 CHAPTER 10 Adding Cards To The System OfficeServ 500 Installation Guide Ed 01 UP this page is intentionally left blank Page 10 6 SAMSUNG Electronics Co Ltd CHAPTE
140. sor SCP is used when the system is expanded to more than one cabinet In a multiple cabinet system the SCP becomes the processor for the first OfficeServ 500 cabinet and communicates via a high speed data link to the MCP The SCP installs in the ninth 9 slot in the first cabinet The SCP can have three daughter boards installed as indicated by the table below SWITCH CONTROL PROCESSOR SCP DAUGHTER BOARD CAPABILITIES Position Types of Daughter Boards allowed per position LOC1 MFM SCM RCM LOC2 MFM RCM MISC LOC3 MFM RCM The SCM must be installed in this position of the SCP in the L system card Do not insert this card with system power ON When it is set to ON and the version of SMARTMEDIA is not match to current system version system S W will be replaced to the S W of SmartMedia VA Only one of any type of daughter board may be installed on any processor Page 3 8 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 3 Installing Printed Circuit Cards MEM Sr i SCM RCM P12 i P2 33 MISC pi Pll Cy gt i CE MFM El RCM K O O l S2 iene hee here ee E Figure 3 4 SCP Card There are 12 LED indicators on the front of t
141. stallation Guide Ed 01 CHAPTER 3 Installing Printed Circuit Cards e Types of VPM 4 Voice and 3 Voice 1 Fax are the two types of VPM 1 4 VPM 4 port voice processing module VPM mounted on this card provides four voice channels or ports This enables 4 callers to use the SVMi 16 service simultaneously One or two of these cards can be added to SVMi 16 2 3 Voice 1 Fax VPM 4 port voice processing module with 1 port supporting Fax VPM mounted on this card provides four voice channels or ports This enables 4 callers to use the SVMi 16 service simultaneously One of these ports can use the Fax service of the SVMi 16 card This module shall be installed on the SVMi 16 motherboard where the duplex connector is most far from the memory module is SAMSUNG Electronics Co Ltd Page 3 41 CHAPTER 3 Installing Printed Circuit Cards OfficeServ 500 Installation Guide Ed 01 34 8WLI Card For future application The 8WLI card provides wireless solution to the OfficeServ 500 system and provides cable interface between the system and WLAN Base Station WBS24 which is the access point for WLAN The cable interface system is a digital system which uses the 2B 1D Digital Adaptor Subscriber Loops DASL interface Interface through the Dual Ports RAM DPRAM is provided for communication with the upper level Main CPU board and is used as the Inter Processor Channel IPC for transmission reception of messages One 8WLI shall be installed in
142. t cover e Cabinet leg mounting kit e AC power and DC power cables Check to see that all additional OfficeServ 500 hardware and software is available for installation at this time Floor mounting equipment legs or castors if required Cards required to make the OfficeServ 500 system functional e g power supply central processor station and trunk cards SAMSUNG Electronics Co Ltd Page 2 1 CHAPTER 2 Installing Single Multiple Cabinet Configurations OfficeServ 500 Installation Guide Ed 01 2 SINGLE CABINET INSTALLATION WALL OR FLOOR MOUNT An OfficeServ 500 single cabinet system can be wall mounted using four screws in the rear keyholes or floor mounted with the standard legs provided or optional locking castors The castor kit must be ordered Remove side and front covers of the cabinet prior to installation to avoid damaging the covers and to allow access to the interior For a wall mounted system the cabinet should be securely mounted on a plywood backboard at least 1 6cm thick Insert into the back board 40cm apart two minimum size 10 screws see Figure 2 1 Figure 2 1 OfficeServ 500 Wall Mounting Hang the OfficeServ 500 cabinet onto the screws installed in the backboard Connect the AC power cord but do not turn ON to the system prior to installing any card Refer to Section Grounding Page 2 2 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 2
143. t shows through the access hole in the base Invert the base assembly over the phone and plug the ribbon cable into the socket on the phone PCB while making sure no damage occurs to the phone PCB Reattach the base to the phone and test to ensure normal phone operation CONNECTING TO THE KDBS There are two methods for connecting devices to Keyset Daughter boards The simplest method is to connect the second device directly by means of a line cord The second method is to use a multi pair station cable connecting separate station Jacks to the first two pairs A line cord can now be connected between the daughter board and the second jack This returns the daughter board port to the MDF for cross connection to another cable run SAMSUNG Electronics Co Ltd CHAPTER 9 Software and Database Management 1 SOFTWARE MANAGEMENT The OfficeServ 500 operating software is stored on the SmartMedia card which is inserted into the front of the MCP card The SmartMedia card has 16 Megabytes of NAND flash memory and is formatted with a custom format to allow faster loading in a similar manner to a hard disk In addition to the operating system the SmartMedia card can carry operating software for the IPM board the LAN board the SCP LCP cards These two cards run the same software and the TEPRI card The SmartMedia card also has the capability to store a backup system database in addition the operating software files The SmartMedia card is suppli
144. tage Directive 73 23 EEC and 93 68 EEC EMC Directive 89 336 EEC 92 3 1 EEC By application of the following standards Pro Oe eee OO REE CEE TT EEE OEE EEE EEE EEE EEE EERE EE HEE DEES EE EEE EEE EEE EEE EEE OOOO Eee eee Bee EEE TEE EOE EE EEE EEE SEE EEE EEE EEE EEE EEE EEE EEE EEE EEE EEE EEE EEE EEE EEE RARE TT EEE EEE EES EEE EEE LVD IEC 60950 3rd Edition 1999 CB scheme Group differences and national differences of the CENELEC countries EEE SU DR EE E TT ET TATE EE RETE TT EEE EEE EEE EEE EEE EEE EEE EES TATE TT EEE DEE EEE EEE EEE EEE DEEDES EEE EEE Pro Eee eee eee Ee EEE STE TT E TT ENTE TRE STE TT TTT EES EEE EEE HEE EEE EEE SEE EEE DEE EEE ESTA TIA STE STE TT EEE EEE EEE OOOO EO Eee Bee EE TT E TT EEE OEE ENTRE RE TT ET TRS TETTE ATE TETTE TT ENTE TT EEE EEE EEE EEE DEES EE EEE EEE EES EEE EEE PO OE Ee Ree Oe EEE TRE TT ET TATE EST EEE EEE EEE EEE TEESE EEE EEE EEE EES EEE EEE EEE DESH TT SEE EEE EEE DEEDES EEE EEE Manufacturer SAMSUNG Electronics Co Ltd 259 KongDan Dong GuMi City KyungBuk Korea 730 030 Dias a p Tae eok Jang General Manager place and date of issue name and signature of authorized person Representative in the EU SAMSUNG Electronics Euro QA Lab Blackbushe Business Park Saxony Way Yateley Hampshire GU46 6GG UK 2003 06 09 o 914 bal In Seop Lee Manager place and date of issue NN name and signature of authorized person UP this page is intentionally left blan
145. tation DBS to a 8BSI port see Figure 6 4 Block Diagram of DECT Structure in OfficeServ 500 M An 8BSI card must be just installed into one of three slots lower than slot4 S1 S2 S3 S4 S5 S6 S7 S8 sg 8BSI card makes it possible to connect 8 DBS Each DBS could make 4 simultaneous calls So 32 DECT handsets can be connected simultaneously to the 8BSI card In general you can register maximum 48 DECT Handsets to the OfficeServ 500 M system Hm SO 0 N ZM SO 0 000 UO Z SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 6 Connecting Station Equipment 7 3 BlockDiagram of DECT Structure in OfficeServ 500 L An 8BSI card must be just installed into one of three slots lower than slot4 S1 S2 S3 S4 S5 S6 S7 S8 S9 EM MEA MS GN S M Three 8BSI cards can be installed to the system O O B B B Cc at the same time Each 8BSI card makes it P P possible to connect 8 DBS Each DBS could make E S i E 4 simultaneous calls So 32 DECT handsets can E E be connected simultaneously to an 8BSI card R R In general you can register maximum 192 DECT 1 2 Handsets to the OfficeServ 500 L system 7 N N N EE EA a Seo d 7 4 Capacity of the DECT in OfficeServ 500 OfficeServ 500 L OfficeServ 500 M Basic Expansion Number of BSI 1 1 3 Number of DBS 8 8 24 MAX Users 48 192 192 Simultaneous calls 32 32 96 1 The maximum quantities of users handset
146. tdetansdeatercobieuaasandaedaccaaben 7 2 3 COMMON i BDT 7 3 d RING OVER PAGE antennes dtnaseateecaor acte peoe Tona i aeaea aa t etes gt etat hat net ade Laine 7 3 5 SMDR AAUCDITRAFFIC ALARMS rire 7 4 6 PC PROGRAMMING iii 7 6 7 VOICE MAIL AUTO ATTENDANT rire 7 7 8 CONNECTING SYSTEM BACKUP BATTERIES TO THE OfficeServ 500 ANA ARA raea aaarnas rauan asupan teaa a inaa sia aeaiee oaia it 7 8 CHAPTER 8 Installing Keyset Daughter Boards 1 iDCS KDB DIGITAL LINE INTERFACE FKDBD iii 8 1 2 iDCSKDB SINGLE LINE INTERFACE FKDBS oooococoocccoccciccnccicccninccnnccninnnnaan acacia 8 1 SAMSUNG Electronics Co Ltd Page XI Table Of Contents OfficeServ 500 Installation Guide Ed 01 3 iDCS KDB FULL DUPLEX FKDBF iii 8 1 AAA A E P E E E E E 8 2 OR A A E 8 2 6 CONNECTING TO THE KDBS lt lt lt lt omcoocoiaiorrnaicaraic iria 8 2 CHAPTER 9 Software and Database Management 1 SOFTWARE MANAGEMENT iii 9 1 1 1 SmarMedia Files ici isa anne Eege ilo dl le 9 1 2 DATABASEMANAGEMENT i i ii ia 9 2 CHAPTER 10 Adding Cards To The System 1 System Upgrade xllciarnaraiiali ia lonie alle eege 10 1 2 ADDING STATIONS AND TRUNKS iiiiiin 10 2 3 GRADING THE OfficeServ 500 FOR DTMF RECEIVERS nn 10 4 4 INSTALLING AA CARD I
147. ter a Dial Conversion Table for Auto Route Selection MCP MCP2 001 oo 0919 gt The first digit 9 added number is sent to the system A for outgoing through trunk line SAMSUNG Electronics Co Ltd Page 12 25 CHAPTER 12 Networking Description and Programming Procedure OfficeServ 500 Installation Guide Ed 01 Program 825 ADD Number To Name Yes Use Remote Voice Mail Yes Remote VM Number 5049 Page 12 26 SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 12 Networking Description and Programming Procedure UY this page is intentionally left blank SAMSUNG Electronics Co Ltd Page 12 27 OfficeServ 500 Installation Guide 2003 SAMSUNG Electronics Co Ltd All rights reserved Information in this document is proprietary to SAMSUNG Electronics Co Ltd No information contained here may be copied translated transcribed or duplicated by any form without the prior written consent of SAMSUNG Information in this document is subject to change without notice Visit us at http www samsungnetwork com ELECTRONICS
148. than 2 5 to this card Except for Australia Australia use an external ringer 4 Ringer Frequency External Ringer 20 Hz 80 Vrms SINUSOIDAL WAVE For Australia and Italy Internal Ringer 25 Hz 80 V RECTANGULAR WAVE For the other countries in Europe 5 SLI port feed voltage is nominally 50VDC SAMSUNG Electronics Co Ltd Page 3 29 CHAPTER 3 Installing Printed Circuit Cards OfficeServ 500 Installation Guide Ed 01 25 8SLI CARD There are no options to select on this card Insert as many 8SLI cards as are needed into universal slots 1 through 7 see Figure 3 2 Push firmly in the middle of both card ejectors on each card to ensure that it is fully inserted into the back plane connector This card automatically detects DTMF or dial pulse signals from the SLT Software and hardware settings are not required When the 8SLI cards are highly utilized with congested traffic the ratio of DTMF receiver will be decreased Therefore the MFM boards or daughter board should be added to a processor card to relieve the bottleneck station devices may be connected to that cabinet However if the cabinet is equipped with two power supply units a maximum of 120 station devices may be connected to that cabinet See the configuration section of the General Description Guide for more details ei 1 If a cabinet is equipped with a single power supply unit PSU B a maximum of 56 2 Do not connect devices with a total REN great
149. the condenser CS by short circuiting the two pins of the mail pin J2 device with a conductor The below two operation modes of VDIAL is set by a digital phone MMC Mode 1 2 channels 7 users 20 words total 280 words Mode 2 1 channel 5 users 40 words total 200 words VDIAL has one jumper JP1 and the location of the shunt pin is determined by the PCM coding law A LAW u LAW as shown on the SYLK screen The diagram below shows the component mounting of the VDIAL board a Do not insert this card with system power ON RAM CLEAR ol Figure 3 27 VDIAL Card Page 3 50 O SAMSUNG Electronics Co Ltd CHAPTER A Power Up Procedures 1 1 1 2 DETERMINING POWER SUPPLY REQUIREMENTS The OfficeServ 500 system software controls the power 48 Volt distribution to the various interface and option cards installed on based Station Equipment Power Units SEPU available Ports on cards will be allocated power up to the capacity of the power available from the PSUs installed Therefore in the case where only 1 PSU is installed or the second PSU becomes faulty only the first 56 station ports will be allocated power Refer to the table below for interface and option card 48V power requirements OfficeServ 500 Power Supply 48 Volt Capacity e PSU60B Slotl 56 ports or SEPUs e PSU60B or PSU 60 Slot 2 64 ports or SEP
150. ting the monitor program for the MGI card The RS232C cable is used for connection with the serial port of the PC SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 3 Installing Printed Circuit Cards ResetButton This button is used to restart the MGI card This button will re execute all programs of the MGI card 6 J3 Connector This connector is used when upgrading the CPLD within the MGI card Refer to the service guide for the operation procedure SAMSUNG Electronics Co Ltd Page 3 49 CHAPTER 3 Installing Printed Circuit Cards OfficeServ 500 Installation Guide Ed 01 38 VDIAL VDIAL is mounted on the subscriber slot of the OfficeServ 500 Premium system and is the module used for making calls by voice rather than pressing the phone buttons The module consists of the RAM where the parameter of multiple words is saved the DSP device which calculates the similarity between each word and the speaker s voice the ROM where the program for transmitting receiving messages between the calculation algorithm program and the main device program is saved and other devices DSP TMS320C31 27MHz ROM EPROM 27C256 x 4 EA RAM SRAM KM681000BLG x 4 EA Since the power is supplied to the RAM through the 1F condenser CS the content is stored for approximately 1 week even if the VDIAL card is dismounted from the system To delete the content stored on the RAM discharge the charge saved in
151. ttendant Centralized Operator To easily call the attendant of another system as if calling an attendant within the same system set the networking dial code as attendant call in Program 724 and set node number attendant group number in Program 824 Call Transfer Reconnect Call Transfer Recall by Join When the call transferred to another system is not answered within the Transfer Recall Time of Program 501 the call is reconnected to the original caller The CT Re Route option of Program 823 shall be set as N The System timer of the original caller operates at the Transfer Recall Time of Program 501 SAMSUNG Electronics Co Ltd Page 12 11 CHAPTER 12 Networking Description and Programming Procedure OfficeServ 500 Installation Guide Ed 01 5 6 7 8 Page 12 12 Call Forwarding The station user can set call forwarding by two methods 1 setting call forwarding to another station in the same system see Program 102 or 2 pressing the call forwarding Transfer function code To set call forwarding the Forward option in Program 701 shall be set to Yes To set call forwarding to a station in another system the EXT FWD option in Program 701 shall be set to Yes In case a call is received from an intercom station when call forwarding is already set to a station of another system the ICM EXT FWD option in Program 201 shall be set to On in order to carry out call
152. tures of WBS24 are summarized below e RF interface meeting the IEEE 802 11b wireless LAN standard e Cable LAN interface meeting the IEEE 802 3 wired LAN standard e 2B ID cable interface with the keyphone system in the rate of 144 Kbps e Voice calls through the keyphone system using the VoWLAN mobile terminal e Provides wireless data to the data terminal that has the wireless LAN interface function Identifies voice data received through wire and transmits to the keyphone system or the LAN network Compression coding and decoding of PCM voice data SAMSUNG Electronics Co Ltd Page 6 11 CHAPTER 6 Connecting Station Equipment OfficeServ 500 Installation Guide Ed 01 Table 6 1 LED Status Display LED No Port No Name Status 1 PWR Displays that power is authorized 2 11 WLAN Displays WLAN link status On Link is connected Off Link is not connected 3 12 LAN Displays Ethernet link status On Ethernet link is connected Off Ethernet link is not connected 4 4 WLI Displays DASL link status On Link to the WLI card is connected Off Link to the WLI card is not connected 5 3 LD1 Displays B channel occupy status On Two B channels are occupied Blink One B channel is occupied Off B channel is not occupied 6 25 LD2 Displays B channel occupy status On Four B channels are occupied Blink Three B channels are occupied Off 0 to 2 B channels are occupied
153. uide Ed 01 7 01 32 Index number representing up to 32 routes 1 4 The number of the time table set in Program 711 Set all numbers as 1 for Korea C The Auto Route Selection class number set in Program 310 G Assigns the trunk line group number M Enters the Dial Conversion Table number in Program 713 when digit conversion is required for outgoing calls VoIP networking is generally used However if you wish to use PRI networking only when VoIP signaling trunk line is all busy or when the Internet network cannot support VoIP calls the class of Program 310 shall be set as 2 or higher and C 1 G 801 and C 2 G 802 shall be set In this case 801 represents the VoIP signaling trunk line group and 802 represents the networking PRI trunk line group Program 713 Convert Auto Route Selection Digit This program is used when digit conversion is required for final outgoing trunk line calls when using the Auto Route Selection feature Fields of the program are described below 001 200 Index numbers of the digit conversion table NOF DEL DGT Sets the number of digits to be deleted starting from the first digit when deleting a portion of the dialled number Only the forepart not the middle or rear part of the digit may be deleted I Inserts digit used to add digits in front of the dialled number A Appends digit used to add digits in the rear part of the dialled number 2 4 Items Required for Additional Features
154. um e E effi d pa N T OH ET en Y GORIZIA A gl api ADA A Enterprise IP Solutions OfficeServ 500 Installation Guide COPYRIGHT This guide is proprietary to SAMSUNG Electronics Co Ltd and is protected by copyright No information contained herein may be copied translated transcribed or duplicated for any commercial purposes or disclosed to third parties in any form without the prior written consent of SAMSUNG Electronics Co Ltd TRADEMARKS OfficeServ 500 iDCS are the trademark of SAMSUNG Electronics Co Ltd Product names mentioned in this document may be trademarks and or registered trademarks of their respective companies Please read this guide before using the OfficeServ 500 and follow the instructions to use the OfficeServ 500 safely and correctly This guide may be changed for the product improvement standardization and other technical reasons without prior notice For further information on the updated guide or the content contained in the guide contact your Authorised SAMSUNG Reseller 2003 SAMSUNG Electronics Co Ltd All rights reserved EU Declaration of Conformity RTTE SAMSUNG Electronics Co Ltd 259 Gongdan Dong Gumi City Kyungbuk Korea 730 030 factory name address declare under our sole responsibility that the product Enterprise IP Solutions OfficeServ 500 to which this declaration relates is in conformity with RTTE Directive 1995 5 EC Annex II Low Vol
155. v 500 system identifies the incoming number as a node number amp a phone number and processes it If the node number is the same as the node number of the system the system removes the node number and connects the call by Program 714 If not the system passes the call to another node Tandem Call If there is no matching number in Program 710 the system treats all incoming numbers as phone numbers without node numbers and connects the call by Program 714 Program 724 Change Dial Numbers STN DIAL NO Shall be set lest all the station numbers of the system connected to networking should be duplicated STNG DIAL NUMBER Shall be set lest all the station group numbers of the system connected to networking should be duplicated to use station groups for calls from the same system NTWK LCR DIAL NO Sets a number used to make a call through the station of another system connected to the networking The number is converted to node number amp station number by Program 824 and arrives at the destination system VOIP NET DIAL NO This is a virtual station used for signaling in VoIP networking It does not need to be specified for networking However its phone number shall be specified to set a trunk line group in Program 603 MGI DIAL NO This is a number for each channel of the MGI card used as voice channel in VoIP networking It does not need to be specified for networking However its phone number shall be specified to set MGI group in Progra
156. ype battery can be used if its rating is not less than 6AH amp hours but no more than 40AH per power supply The batteries must be located within Imetre feet of the KSU Use the factory supplied wire harness with Imetre white and black leads to connect batteries see Figure 7 7 Observe the following precautions when installing batteries a Make sure the batteries you install conform to local building fire and safety codes Some battery types emit hydrogen gas during the charging state and may require venting to fresh air b Donot place batteries directly on a concrete floor This causes them to discharge very quickly c Follow the battery manufacturer s recommended installation and maintenance procedures d The backup batteries must provide a 125V SA fuse per cabinet to protect the system from excessive discharge SAMSUNG Electronics Co Ltd OfficeServ 500 Installation Guide Ed 01 CHAPTER 7 Connecting Optional Equipment CONNECT TO EITHER A OR B OPTION 8 BATTERIES SHOULD BE PLACED WITHIN THREE FEET OF KSU Figure 7 9 Reserve Power Battery Connections SAMSUNG Electronics Co Ltd Page 7 9 CHAPTER 7 Connecting Optional Equipment OfficeServ 500 Installation Guide Ed 01 UP this page is intentionally left blank Page 7 10 SAMSUNG Electronics Co Ltd CHAPTER 8 Installing KDB Keyset Daughter Boards 1 iDCSKDB DIGITAL LINE INTERFACE FKDBD This is a daughter board that can be installed only i