Home

LED BAR 260

image

Contents

1. 9 as amended by the CE Marking Directive 93 68 EEC 1993 D amp R Electronica Weesp b v Rijnkade 15 B 1382 GS WEESP The Netherlands President of Engineering Manual page 4 PRODUCT SAFETY This product is manufactured with the highest standards and is double checked in our quality control department for reliability in the HIGH VOLTAGE section CAUTION Never remove any panels or open this equipment No user serviceable parts inside Equipment power supply must be grounded at all times Only use this product as described in user manual or brochure Do not operate this equipment in high humidity or expose it to water or other liquids Check the AC power supply cable to assure secure contact Have your equipment checked yearly by a qualified dealer service center Hazardous electrical shock can be avoided by carefully following the above rules EXTRA CAUTION FOR LIVE SOUND Ground all equipment using the ground pin in the AC power supply cable Never remove this pin Ground loops should be eliminated only by use of isolation transformers for all inputs and outputs Replace any blown fuse with the same type and rating only after equipment has been disconnected from AC power If problem persists return equipment to qualified service technician PLEASE READ THE FOLLOWING INFORMATION Especially in sound equipment on stage the following information is essential to know An electrical shock is caused by voltage and current actually i
2. AIRLAB broadcast mixer The 25 pole male and female XLR connectors are standard MambaNet connectors for the DER AXUM platform Y DW Meter EROF Left Right In Je Thru Level adjustment Level adjustments can be made using the trim pot positioned between the 2 XLR connectors of each Led Bargaph meter Turning the trimmer clockwise increases the level counter clockwise decreases the level For instance adjusting the level at 0 dB means turning the trimmer clockwise until the 0 dB led just lights Default settings for both channels are at 0 dB when the actual input is a 4 dB signal sinewave Measuring 4 dB output level with an AC voltmeter would give a 1 22 Volt AC reading Manual page 3 Specifications Level range 50dB to 5 dB Frequency range 10 60 000 Hz Power consumption 50mA 230VAC max Input impedance 10kOhm Dimensions Front panel 241 10 mm x 44 mm Dimensions Frame 199 50 width by 72mm depth and 41mm height NOTE before use read the safety instructions on the separate sheet very DECLARATION OF CONFORMITY Manufacturers Name D amp R Electronica Weesp b v Manufacturers Address Rijnkade 1 5B 1382 GS Weesp The Netherlands declares that the product PPM 260 Ledbar conforms to the following product specifications EMC EN 55022 1987 CISPR 22 1993 class B EN 500082 1 1992 Supplementary Information The products herewith complies with the requirements of the EMC Directive 89 336 EEC 198
3. HIGH RESOLUTION 260 LEDBAR PPM USER Manual page 1 Geachte klant Wij danken u hartelijk voor uw keuze en het vertrouwen dat u in ons product stelt U deed een goede keus dit product is ontworpen door en voor professionele gebruikers Er is gebruik gemaakt van onze enorme know how in mengtafel en signaal processor technieken en dit gecombineerd met hoogwaardige componenten geeft u de zekerheid van een lange gebruiksduur Bovenstaande eigenschappen resulteren in een zeer betrouwbaar en bedrijfszeker eindproduct Deze gebruiksaanwijzing helpt u in het optimaal benutten van alle mogelijkheden die dit product in zich heeft Wij excuseren ons voor het feit dat deze gebruiksaanwijzing uitsluitend in het Engels verkrijgbaar is Dit is een gevolg van het feit dat 99 van onze producten ge xporteerd worden en het Engels de algemeen aanvaarde internationale voertaal is Mocht u nog vragen hebben dan kunt u zich altijd tot onze dealers wenden Dear client Thank you for choosing this product This product is designed by specialists in the field of professional audio and is intended to be used as a professional tool We are confident that you will be using this product for many years to come and wish you much success We always value suggestions from our clients and we would therefore be grateful if you could complete and return the questionnaire included at the back of this manual once you have become familiar with this product We wil
4. RESS TOWN POST CODE COUNTRY EMAIL info d r nl PURCHASING DATE DEALER HOW DID YOU HEAR ABOUT THIS PRODUCT please circle Dealer Advertisement Exhibition Other user Other WHAT IS YOUR OPINION OF THE PRICE QUALITY OF THE 260 PPM METER WHAT PRICE WOULD YOU CONSIDER SUITABLE FOR THE 260 PPM ANY OTHER SUGGESTIONS I REQUIRE INFORMATION ABOUT WHAT OTHER EQUIPMENT DO YOU USE PLEASE SEND MAIL TO D amp R Electronica Weesp bv Rijnkade 15B 1382 GS WEESP The Netherlands FAX 31 294 416987 Manual page 7 260 PPM SERVICE MANUAL ON REQUEST Manual page 8
5. ase do check if there is any potential between the housing of the mikes and the guitar synth amps which will be linked by your body on stage Imagine a guitar in your hand and vour lips close to the mike A ground potential difference of above 10 volts is not unusual in improperly wired buildings it can possibly be as high as 240 volts Manual page 5 Although removing the ground wire sometimes cures a system hum it will create a very hazardous situation for the performing musician Always earth all your equipment by the grounding pin in your mains plug Hum loops should be only cured by proper wiring and isolation input output transformers Replace fuses always with the same type and rating after the equipment has been turned off and unplugged If the fuse blows again you have an equipment failure do not use it again and return it to your dealer for repair And last but not least be careful not to touch a person being shocked as you yourself could also be shocked Once removed from the shock have someone send for medical help immediately Always keep the above mentioned information in mind when using electrically powered equipment Manual page 6 Dear CLIENT We care very much about your opinion of our product and would very much appreciate if you could complete the following questionnaire and return it to the address below Please use a copy of this form if you do not want to damage your manual USER NAME ORGANIZATION ADD
6. l certainly learn from your comments and very much appreciate your time doing this With kind regards D amp R ELECTRONICA WEESP B V Rijnkade 15B 1382 GS WEESP HOLLAND The Netherlands Phone 0294 418 014 Fax 0294 416 987 Duco de Rijk President Email info d r nl Website www d r nl Manual page 2 OVL 63 0 5 ve NOA MOROSO OVL 50 100 180 HI RESOLUTION 260 LEDBAR Introduction The 2x 60 segment Led Bargaph meter is a professional dual audio peak level meter It provides accurate readings between 50 up and 5 dB Housed in a standard 9 5 inch stainless steel case it has been designed to be used in various environments Powering up Before connecting the unit to the digital Power adapter check for the appropriate voltage it should be between 100 volt and 240 volt The meter will deflect once and then settles The ON led indicates that power is connected and that the meter is on If at any time this led is not lit when the unit is connected to the mains you should disconnect the unit and contact D amp R for service advice The two balanced XLR female connectors are used as inputs left and right This is where the audio analog signal must be connected 1 Ground 2 Hot and 3 Cold Once connected to the audio source the meter will display peak levels between 50 up to 5 dB in 60 steps There is also a 9 pole Sub D connector that has been wired to directly interface with a meter output on the DER
7. t is the current that causes the shock In practice the higher the voltage the higher the current will be and the higher the shock But there is another thing to consider and it is resistance When the resistance in Ohms is high between two poles the current will be low and vice versa All three of these voltage current and resistance are important in determining the effect of an electrical shock However the severity of a shock primarily determined by the amount of current flowing through a person A person can feel a shock because the muscles in a body respond to electrical current and because the heart is a muscle it can affect when the current is high enough Current can also be fatal when it causes the chest muscles to contract and stop breathing At what potential is current dangerous Well the first feeling of current is a tingle at 0 001 Amp of current The current between 01 Amp and 0 2 Amp is fatal Imagine that your home fuses of 20 Amp can handle 200 times more current than is necessary to kill How does resistance affect the shock a person feels A typical resistance between one hand to the other in dry condition could well over 100 000 Ohm If you are playing on stage your body is perspiring extensively and your body resistance is lowered by more than 50 This is a situation in which current can easily flow Current will flow when there is a difference in ground potential between eguipment on stage and in the P A system Ple