Technical Service Bulletin 030614 IOT High Voltage
Contents
1. Place transmitter in HV ISOLATED mode by actuating high voltage isolate relay from HPA control panel NOTE Certain IOX and DCX transmitters feature mechanically latching high voltage isolate relays Others have non latching relays that require a continual voltage from the HPA controller to remain in the ISOLATED state These non latching relays will relax to the CONNECTED position when AC power is removed from the transmitter In such cases it is necessary to physically remove the red HV wire lead from the HV isolate relay to achieve the desired isolated condition 2 Turn transmitter completely off and disconnect all mains power to transmitter REV B2 13 February 2004 COMARK Communications Technical Service Bulletin 030614 Gain access to HPA high voltage compartment via key interlock system Discharge all high voltage circuits in high voltage compartment with grounding hook Visually inspect high voltage HV compartment for any signs of carbon marks pinholes or damage to red jacket of HV wires signs of corrosion in any plastic or Teflon materials These are all indications of a possible high voltage standoff problem Disconnect red HV wire from grounding switch to white high voltage capacitor on wall of high voltage compartment Reroute disconnected wire to maintain it far from circuit under test Disconnect J3 from crowbar HV upper section Reroute disconnected wire to maintain it permanently grounded and far
2. REV B2 13 February 2004
3. beam supply output to crowbar input This section describes how to test the high voltage standoff capabilities of the high voltage cables connecting the beam supply output to the crowbar input This test is performed when the transmitter is not able to withstand high voltage in HV ISOLATED mode fails with a trip of the motorized circuit breaker but WITHOUT a crowbar triggered fired indication and proper crowbar operation has been verified thereby suggesting an arc in the high voltage circuit before the crowbar Turn transmitter completely off and disconnect all mains power to transmitter Place outdoor safety disconnect in 480VAC feed to HV beam supply in the OFF position Gain access to HV beam supply Thoroughly ground all HV circuits inside beam supply with grounding hook Be sure to SIMULTANEOUSLY ground BOTH posts of each filter capacitor This may require the modification of the grounding hook straighten bend Asa safety precaution permanently short circuit the positive and negative terminals of the filter capacitors using a wire or clip lead Disconnect HV and HV wires to HPA cabinet from high voltage bushings inside HV beam supply Disconnect J3 from crowbar HV upper section in high voltage compartment Reroute disconnected wire to maintain it far from circuit under test and from any grounded surfaces Connect HV GND lead from hipot test to HV lead to transmitter REV B2 13 February 2004 COMARK
4. from circuit under test Connect HV GND lead from hipot test set to grounded frame of transmitter Be sure to connect to a bare non painted metal surface Connect HV lead from hipot test set to connection stud of white high voltage capacitor WARNING Verify that connection J3 is indeed broken at the crowbar and that no connection exists between the portion of the high voltage circuit under test and the high voltage beam supply Otherwise it is possible to charge the beam supply filter capacitors with the high pot test set thereby creating a potentially lethal situation Turn hipot test set voltage adjustment to zero volts Connect AC mains voltage to hipot test set Turn off all lights and any sources of ambient noise Activate hipot test set and apply high voltage to transmitter increasing slowly from zero volts up to maximum of 40 kV Listen carefully for any voltage breakdowns indicated by audible hissing popping crackling or other noises Visually inspect all high voltage circuits for glowing corona discharges Adjust current limit adjustment SL60N300 next to current meter as necessary to prevent hipot test from entering current limited mode CURRENT display lights WARNING During this test it is normal to observe a surge of current each time the voltage is raised This surge will taper off and the voltage will slowly increase This is due to the slow accumulation of charge in the white high
5. prepare it for service Remove front and rear covers from reinforced shipping case Connect green yellow ground wire to ground stud at rear of unit Connect insulated HV lead to test set and thread connector shell to chassis connector see photo If banana plug at end of HV lead will not seat fully inside unit threads will not engage remove HV lead check for straightness lightly bend cable to maximize straightness and re attempt to establish connection 4 Connect modular AC cord to rear of unit REV B2 13 February 2004 COMARK Communications Technical Service Bulletin 030614 To test IOT and high voltage compartment after HV isolate relay This section describes how to test the high voltage standoff capabilities of the high voltage circuit from the HV isolate relay to the IOT This test is performed when the transmitter is able to withstand high voltage in HV ISOLATED mode but crowbars immediately while in HV CONNECTED mode thereby suggesting an HV flashover in the high voltage circuit occurring after the HV isolate relay NOTE IOX and DCX users may find it useful to consult drawing 451890 Schematic HV Compartment HPA Manual Chapter 12 Advantage users may find it useful to consult drawing 46744001 pgs 5 6 Interconnect Advantage Service Manual Chapter 4 2 Place transmitter in HV ISOLATED mode by actuating high voltage isolate relay from HPA control panel NOTE Certain IOX and DCX tran
6. voltage capacitor Raise the test set voltage very slowly in small increments allowing the current surge to abate after each step before proceeding Although necessary to test the standoff capabilities of the capacitor this buildup of charge presents a potential safety hazard ALWAYS directly discharge this capacitor with the grounding hook at the end of the test Do not place ears or eyes close to high voltage compartment in an attempt to detect voltage breakdowns Always maintain all body parts at least one foot from the front of the open high voltage compartment REV B2 13 February 2004 COMARK Communications Technical Service Bulletin 030614 14 If corona or partial breakdowns are discovered turn off and fully discharge hipot test set and attempt to eliminate cause of breakdown by increasing standoff distances where possible rounding off any sharp corners with a fine grain sandpaper or file where applicable or cleaning any localized dust accumulation with denatured alcohol and a clean rag If complete HV breakdown is observed bright flash and or hipot trips attempt to locate source of breakdown by progressively disconnecting portions of high voltage circuit and repeating hipot test Locate source of breakdown and remedy and or replace damaged components Restore original high voltage circuit connections and close high voltage compartment Procedure complete To test high voltage cables from
7. COMARK Communications Technical Service Bulletin 030614 Technical Service Bulletin 030614 IOT High Voltage Troubleshooting with Hipot Test Set Procedure 030614 IOT High Voltage Troubleshooting with Hipot Test Set Applicability IOX DCX and Advantage transmitters Prerequisites Knowledge of high voltage safety procedures Knowledge of First Aid procedures Second person must be present at all times Equipment Required Hipot test set Comark rental Spellman SL60N300 unit or otherwise Comments When high voltage will not turn on stay on due to motorized breaker trips and or crowbar alarms The procedure described in this document involves potentially dangerous high voltages While the high pot test set operates on the principal of high voltage low current to maximize personnel safety it is nevertheless critical that proper high voltage safety procedures be employed at all times Do not attempt this procedure without a second person present Do not attempt this procedure while tired or otherwise not fully alert Always use the transmitter grounding hook to properly ground all high voltage circuits before attempting to touch them Consult Service Bulletin 940911 for information on proper high voltage safety procedures To assemble rental Spellman SL60N300 high pot test set Comark has several Spellman SL60N300 high pot test sets for rent This section describes how to unpack the rental unit and
8. Communications Technical Service Bulletin 030614 9 Connect HV lead from hipot test set to HV lead to transmitter 10 Turn hipot test set voltage adjustment to zero volts 11 Connect AC mains voltage to hipot test set 12 Activate hipot test set and apply high voltage to transmitter leads increasing slowly from zero volts up to maximum of 40 kV Observe hipot test set meters looking for any sudden jumps in current drops in voltage or sudden changeover to current limited mode CURRENT display lights These are all signs of a voltage breakdown If voltage breakdown is observed HV cables from beam supply are damaged and must be replaced NOTE If HV cables pass test beam supply may have internal short Restore equipment original condition except leave HV lead to transmitter disconnected Attempt to activate beam mode on transmitter with HV lead disconnected at beam supply output If motorized breaker continues to trip there may be a short internal to the beam supply or on the 480 VAC primary feed to the transformer Likely causes of an internal beam supply short are a faulty rectifier stack transpack faulty HV filter capacitor or short circuited transformer windings Contact Comark or beam supply manufacturer for further assistance 20 Return equipment to original condition 21 Procedure complete Comark Communications 104 Feeding Hills Road Southwick MA 01077 U S A 800 345 9295 Attn Customer Service
9. fully discharge hipot test set and attempt to eliminate cause of breakdown by increasing standoff distances where possible rounding off any sharp corners with a fine grain sandpaper or file where REV B2 13 February 2004 COMARK Communications Technical Service Bulletin 030614 applicable or cleaning any localized dust accumulations with denatured alcohol and a clean rag NOTE Localized dust accumulations on high voltage wires and or the walls of the high voltage compartment dust shadows are signs of enhanced voltage stress in these areas see photo When such an accumulation is discovered it should be removed with a cleaning rag and the high voltage wires re routed with greater standoff distances when possible to prevent a reoccurrence The high voltage wire on the left was moved to expose a dust shadow on the wall of the high voltage compartment A fingerprint smudge in the center of the smudge helps verify its presence 14 If complete HV breakdown is observed bright flash and or hipot trips attempt to locate source of breakdown by progressively disconnecting portions of high voltage circuit and repeating hipot test For example repeat test after having removed socketed tube where applicable repeat test after having disconnected IOT junction box connections repeat test after having disconnected HV filament grid and ion wires from filament bias ion supply output repeat test after having discon
10. nder test and the high voltage beam supply Otherwise it is possible to charge the beam supply filter capacitors with the high pot test set thereby creating a potentially lethal situation REV B2 13 February 2004 COMARK Communications Technical Service Bulletin 030614 Photo of high pot test set HV lead to FBI supply body The dangling high voltage wire in the upper right of photo is the disconnected wire from the ground switch as described above It is temporarily supported by the HV compartment door locking mechanism 9 Turn hipot test set voltage adjustment to zero volts 10 Connect AC mains voltage to hipot test set 11 Turn off all lights and any sources of ambient noise 12 Activate hipot test set and apply high voltage to transmitter increasing slowly from zero volts up to maximum of 40 kV Listen carefully for any voltage breakdowns indicated by audible hissing popping crackling or other noises Visually inspect all high voltage circuits for glowing corona discharges Adjust current limit adjustment SL60N300 next to current meter as necessary to prevent hipot test from entering current limited mode CURRENT display lights WARNING Do not place ears or eyes close to high voltage compartment in an attempt to detect voltage breakdowns Always maintain all body parts at least one foot from front of open high voltage compartment If corona or partial breakdowns are discovered turn off and
11. nected floating 120 VAC feed from HV isolation transformer to FBI supply etc REV B2 13 February 2004 COMARK Communications Technical Service Bulletin 030614 NOTE A special adapter that allows simultaneous connection to all IOT leads cathode filaments grid and ion is supplied with the Thales rental hipot test set photo at right 15 Locate source of breakdown and remedy and or replace damaged components 16 Restore original high voltage circuit connections and close high voltage compartment 17 Procedure complete To test high voltage circuit from crowbar to HV isolate relay This section describes how to test the high voltage standoff capabilities of the high voltage circuit from the crowbar to the HV isolate relay This test is performed when the transmitter is not able to withstand high voltage in HV ISOLATED mode but IS able to withstand high voltage when J3 HV input to crowbar is disconnected and more basic troubleshooting strategies have failed i e replace troubleshoot crowbar assembly NOTE IOX and DCX users may find it useful to consult drawing 451890 Schematic HV Compartment HPA Manual Chapter 12 Advantage users may find it useful to consult drawing 46744001 pgs 5 6 Interconnect Advantage Service Manual Chapter 4 2 NOTE For more information on crowbar troubleshooting please consult Comark document 46744354 Troubleshooting Procedure Thyratron Crowbar
12. smitters feature mechanically latching high voltage isolate relays Others have non latching relays that require a continual voltage from the HPA controller to remain in the ISOLATED state These non latching relays will relax to the CONNECTED position when AC power is removed from the transmitter In such cases it is necessary to physically remove the red HV wire lead from the HV isolate relay to achieve the desired isolated condition Turn transmitter completely off and disconnect all mains power to transmitter Gain access to HPA high voltage compartment via key interlock system Discharge all high voltage circuits in high voltage compartment with grounding hook Visually inspect high voltage HV compartment for any signs of carbon marks pinholes or damage to red jacket of HV wires signs of corrosion in any plastic or Teflon materials These are all indications of a possible high voltage standoff problem Disconnect red HV wire from grounding switch to filament bias ion supply case Reroute disconnected wire to maintain it far from circuit under test Connect HV GND lead from hipot test set to grounded frame of transmitter Be sure to connect to a bare non painted metal surface Connect HV lead from hipot test set to filament bias ion supply case WARNING Verify that high voltage isolate relay is indeed in the isolated open position and that no connection exists between the portion of the high voltage circuit u
Download Pdf Manuals
Related Search
Related Contents
K C S - Induslubre Cables Unlimited IOC-7700 取扱説明書 - オークセール Descargar ficha técnica BLE010V2 67.EPC Operation - Custom Service Hardware Outdoor Storage Shed Shutter Kit Kit de contraventanas para el Lexmark T420(n) Laser Printer (4048) USER`S MANUAL - Moore Industries International Copyright © All rights reserved.