1. Polarity lt fmt_num gt polarity NORMAL REVERSE Photometric lt fmt_num gt photmetric_in RGB Color MONOCHROME 4 Black on White 0 pix white Interpretation MONOCHROME2 White on Black 0 pix black eNTEGRA P amp R Service Manual Direction 2263784 100 3 84 Rev 5 June 17 2001 Installation Hardcopy Options Table 3 36 DICOM Print Parameters Default Settings Default Settings DICOM Parameter Imation 8300 Imation 8700 Codonics AGFA Color AGFA B amp W DCMI8300 DCMI8700 DCMcod DCMA2KCl DCMA2KBW IP Address imation imat8700 codicom agfa2k agfa2k See Note AE Title 3M_8300 3M_PrintServer PRINT_SCP Drystar Drystar Port 104 1024 104 104 104 Medium Type CURRENT CURRENT PAPER CLEAR CLEAR Film PROCESSOR CURRENT PROCESSOR PROCESSOR PROCESSOR Destination Film Orientation LANDSCAPE PORTRAIT LANDSCAPE LANDSCAPE LANDSCAPE Film Size ID 8INX10IN 14INX171N 8INX10IN 8INX10IN 8INX10IN Mag Type CUBIC CUBIC BILINEAR CUBIC CUBIC Max Density 300 300 64000 Default Default Min Density 0 0 0 Default Default Border Density BLACK BLACK WHITE 200 200 Empty Image BLACK BLACK WHITE 200 200 Dens Polarity REVERSE NORMAL NORMAL NORMAL NORMAL Photometric MONOCHROME1 MONOCHROME1 RGB RGB MONOCHROME 1 Interp Note The IP Address is associated with the host name listed in Table 3 35 The host name and IP Address are added to the Hosts
2. 6 22 6 2 16 3 Verifying InSite user accounts and passwords eeseeeeeeeeeeeeeeeeeereeee 6 23 6 2 16 4 Re nstallation of Service Pack G scicnisiasiicrieina 6 24 6 2 16 5 Installation of VNG Ser ven sascsiccviesaceucessaienctedseandicrsiantasariendereeabeaniadind 6 25 6 3 Sokware Load trom Walii esseenigesspeasiii nnn N 6 26 6 3 1 O a E E E E A E A E E 6 26 6 3 1 1 eiA ea a E E A S E E E A Te EEE 6 26 03 1 2 PoCo sin S E ON 6 26 6 3 2 Full Shut Down of the eNTEGRA Application sssssesesesesesessseessressses 6 26 6 3 3 Pe UPT rerea a E aonieenaaiee 6 26 6 4 Installing eNTEGRA Software Options and Licenses 6 27 6 4 1 Tae the LUC ee R E 6 27 6 4 2 Tnstalline the OSL OPHION os cache aS 6 29 6 4 2 1 VEIN IO saaren aoe eoeel ed eee 6 29 6 4 2 2 Installing the IMPART ISO 8073 Network Driver eeeeeeeeeees 6 30 6 4 2 3 Installing the Boldon James ADI Program 6 31 6 4 2 4 Distalline a Paeh tor ADi alana aareiniee 6 31 6 4 2 5 Configuring the eNTEGRA on Remote OSI Stations eee 6 31 Chapter 7 System Upgrade nnciiennkncniiasaennnaneeein 7 1 eNTEGRA P amp R Service Manual v Rev 5 Direction 2263784 100 June 17 2001 Table Of Contents 7 1 Addins an Ot De ele eee 7 1 7 1 1 Installing Archive Optical Disk in PC Tower sj iiccicssaceacasscsienssaaovcsasnoceeunseas 7 1 Sole System Coniiguraton and Teie ereinen 7 2 Chapter 8 Troubleshooting and Repair cccssssscccssssssssccsssssssssccesssseseees 8
3. Cable ar Part Run Description Source Length Reference 1 Peripheral Tower SCSI 46 325201P5 1m Section 5 1 3 Cable 2 37 Pin LCAM Image Konica 3 10 m_ Konica Service Data Cable RS485 Engineer 3 25 Pin Male to 37 Pin Konica Female RS422 Stub Cable 4 37 Pin RS422 Host Konica Communication cab le Note Refer to Section 5 1 3 1 for pinout details on the DASM LCAM eNTEGRA P amp R Service Manual Direction 2263784 100 3 64 Rev 5 June 17 2001 Installation Hardcopy Options b Interface Configuration The Konica Lasercamera s input module must be configured to communicate with the eNTEGRA Table 3 25 summarizes the configuration parameters that need to be set on the input module for the DASM LCAM interface The Konica Service Engineer will be responsible for configuring and interfacing Lasercamera Table 3 25 DASM LCAM to Konica Lasercamera Interface Configuration Interface Parameter Setting Host Communications Baud Rate 1200 Stop Bits 1 Data Bits 8 Parity Even Parity Enable Enable Character Pacing 0 End Of Message CR Protocol ACK NACK Host Protocol 952 Type Image Image Size 1024x1024 Pixel Width 8 Parity Even Parity Enable Enable 3 10 6 4 Image Quality Configuration The 952 protocol image quality parameters defined in HCdefaults win32 file are ignored by the Konica Lasercamera All
4. C 16 eNTEGRA P amp R Service Manual vii Rev 5 Direction 2263784 100 June 17 2001 Chapter 1 Safety Guidelines and Regulatory The safety precautions and regulatory information included in this chapter are provided in the following sub sections e General Safety Guidelines on page 1 1 e Hazards on page 1 3 e Electrical Precautions on page 1 3 e Installation Safety Measures on page 1 4 e Safety Definitions on page 1 4 e IEC Symbols on page 1 5 e Regulatory Information on page 1 6 1 1 General Safety Guidelines 1 The system has been designed and manufactured to ensure maximum safety of operation The equipment should be serviced in strict compliance with the safety precautions warnings and operating instructions contained in this Service Manual The product should be installed maintained and serviced only by qualified service personnel according to procedures laid down in this manual The owner should make certain that only properly trained fully qualified service engineers are authorized to service the equipment There are no user serviceable parts inside system components such as workstation cabinet or monitor Any servicing or adjustments required must be carried out by a competent and suitably qualified service person The system has been designed to meet all the safety requirements applicable to medical equipment However anyone attempting to operate the system must be fully aware of potential safety hazard
5. When all remote Interfile stations have been added click the OK button to close the ENTEGRA Configuration window Click Apply to exit the User Preferences window eNTEGRA P amp R Service Manual 3 21 Rev 5 Direction 2263784 100 June 17 2001 Installation Site Configuration 3 8 4 8 Remote Access Configuration 1 AM amp SN x Click right on the Network Neighborhood icon residing on the desktop and select the Properties entry in the opened menu In the opened Network dialog click on the Services tab Highlight the Remote Access Service entry Click the Properties button to open the Remote Access Setup dialog Click the Configure button In the opened Configure Port Usage dialog click the radio button next to Dial out and Receive calls then click OK In the Remote Access Setup dialog click Network 8 In the Network Configuration dialog verify that 10 11 12 13 14 15 16 a Under Dial out Protocols TCP IP is checked b Under Service Settings TCP IP is checked c Under the Encryption Settings click the radio button next to Allow any authentication including clear text In the Network Configuration dialog click Configure In the Ras Server TCP IP Configuration dialog click the radio buttons next to This computer only and Use static address pool Type in the modem begin and end IP addresses Check the checkbox next to Allow remote clients to requ
6. If necessary adjust the Windowing tool for better view of the heart in the Rest planar image displayed If necessary move the central marker to display the left ventricle in the Rest Live Image Set the reconstruction limits on the Rest Planar Image displayed Click Proceed on the control area The VLA HLA and SA obliques for the rest data are created When the Stress Planar Image appears in the upper left corner of the screen set the reconstruction limits for the stress data as described in step 4 above for the rest data Then click Proceed on the control area When the VLA HLA and SA obliques for the stress data are created click the Back button on the control area Click the Stress Gated Data Only or Rest Gated Data Only whichever applies to the input data When the control area displays the prompt Proceed with Current Gated Recon Filters click Proceed When the VLA HLA and SA obliques are created for the eight gates click on the Process Tab Click the Process tab and verify the available licenses as follows For the complete ECToolbox license a Verify that both CEqual Quantification and Functional Anal ysis buttons are enabled b Click the CEqual Quantification button c Click Proceed d Inthe Normal Database window opened click the gender corre sponding to the input data then click OK e Verify that Generate 3 D is enabled For CEqual Light licence verify that the
7. Verify that all other boxes are unchecked then click OK Close the User Manager window eNTEGRA P amp R Service Manual 6 23 Rev 5 Direction 2263784 100 June 17 2001 Software Installation Software Load From Cold For Dell OptiPlex GX200 6 2 16 4 Re installation of Service Pack 6a This installation depends on the language being used 1 For English version Insert the eNTEGRA Application CD into the CD Drive and double click the My Computer icon located on the desktop For other languages Insert the eNTEGRA Accessories Software CD into the CD Drive and double click the My Computer icon located on the desktop Double click the D drive CD ROM Drive 3 Double click the SP6 directory 5 For the English version skip to step 5 below For other languages double click the applicable language directory Double click SP6ai386 exe Note if an Incorrect Service Pack version message appears browse to SO 50 USI SON C WINTN system32 rename Schannel dll to Schannel dl2 and double click SP6ai386 exe again Check the Accept License Agreement box if requested Uncheck Backup files necessary to uninstall service pack Click Install When prompted click on Restart to reboot the system and logon as before eNTEGRA P amp R Service Manual 6 24 Rev 5 Direction 2263784 100 June 17 2001 Software Installation Software Load From Cold For Dell OptiPlex GX200 6 2 16 5
8. Verify that all patient data is backed up Back up the Archive Log Index directory C ArcLog before starting the software load from cold procedure 6 2 1 1 Time Required The time required to complete the installation of the basic software is 1 5 hours about 90 minutes eNTEGRA P amp R Service Manual 6 2 Rev 5 Direction 2263784 100 June 17 2001 Software Installation Software Load From Cold For Dell OptiPlex GX200 6 2 1 2 Procedure Overview The load from cold procedure consists of the following steps to be performed in the given order The load from cold procedure consists of the following steps to be performed in the given order 1 2 gt 15 16 17 18 19 20 Disconnecting Existing Optical Disk Drives if Applicable on page 6 4 Setting the System BIOS on page 6 4 Installing the Windows NT Operating System on page 6 5 including disk partitioning and formatting Drive C Installing Windows NT Networking on page 6 7 Installing Service Pack 6a on page 6 10 Installing the Display Driver on page 6 11 Adjusting the Display Properties on page 6 12 Installing the Sound Driver on page 6 13 Setting System Options on page 6 13 Installing Internet Explorer 5 on page 6 15 Installing RAS Modem and TCP IP Printing on page 6 16 Installing the FTP Service on page 6 18 Formatting Drive D as NTFS on page 6 19 Installing the eNTEGRA Application and Its Accessory Components on
9. 4 10 InSite Operation Check Double click the iLing Shell icon on the desktop At the system prompt type insite_brouser lt Enter gt If the Netscape Navigator window appears click No The InSite home page application will be displayed provided that licenses were downloaded during checkout This screen is the launching point for InSite Applications for customers In the Main Screen HOME click Contact GE The Contact GE screen is displayed Type in the problem encountered at the appropriate type in fields and click SUBMIT If all the connections are OK and the On Line Center OLC recognizes the licenses sometimes a delay in license processing occurs for in house systems within 4 minutes a successful screen will be displayed Otherwise an error screen will be seen In either case a Customer Message will be seen as a new message on the Main Screen Application eNTEGRA P amp R Service Manual 4 9 Rev 5 Direction 2263784 100 June 17 2001 Chapter 5 System Description The eNTEGRA system is described according to the following breakdown e Section 5 1 Hardware Description on page 5 2 o Section 5 1 1 System Block Diagram on page 5 2 Section 5 1 2 Hardware Components on page 5 3 o Section 5 1 3 Cabling and Linking on page 5 4 o Section 5 1 4 Sony EOD on page 5 7 Section 5 1 5 DASM LCAM on page 5 9 e Section 5 2 Software Description on page 5 10 o Section 5 2 1 Software St
10. While trying to export to Interfile or DICOM Part 10 the following message appears Can t find RAS dIl RAS Installation was skipped Install the RAS as per Section 6 2 12 on page 6 16 eNTEGRA P amp R Service Manual Direction 2263784 100 8 4 Rev 5 June 17 2001 Troubleshooting and Repair Troubleshooting 8 2 5 Printing Problems Table 8 2 Printing Problems Symptom problems TCP IP printers printing Possible Cause Wrong Configuration on local system Corrective Action Open Config from the eNTEGRA Main screen Check the printer settings in the Printer tab and correct if necessary Printer disconnected Double click the ENTEGRA Prompt icon on the desktop Type ping Hostname lt Enter gt where Hostname refers to the hostname of the remote station If the remote station does not replay it is not available Codonics printing TCP IP problems problems in addition to Wrong configuration on the Codonics Connect to Codonics using telnet and check the printer status as per Section 8 2 6 If not contact Codonics service Missing Codonics software patches 1 Connect to Codonics using telnet as per Section 8 2 6 steps 1 4 The telnet session will display any communication between the eNTEGRA and the Codonics At the UNIX prompt type more etc updates lt Enter gt Verify that the Ipd and snnpd p
11. e SP system s documentation eNTEGRA Ethernet LAN address eNTEGRA computer name e e e Configure all remote DICOM 10 system Remote DICOM system s documen systems tation Use the following parameters AE Title eNTEGRA hostname in uppercase Port No 104 e Total 80 system 3 9 3 eNTEGRA Ethernet Address 1 Click on the minimize button on the Main Screen Header to view the system s Desktop 2 Click left on the Start icon on the Tasks Bar and select Programs gt Impart 32 Command Line Manager Type D lt Enter gt for full display 4 Under the DTE column you will find the Ethernet address of the local eNTEGRA system a 12 characters number Record the Physical Ethernet address displayed in the site log book 5 Type q lt Enter gt to quit eNTEGRA P amp R Service Manual 3 29 Rev 5 Direction 2263784 100 June 17 2001 Installation Remote LAN Configuration 3 9 4 Starlink Version 4 Upgrade for Polestar and Polestar i Systems Shut down the Polestar system by entering shutdown lt Sendform gt Reboot the system by pressing the RESET button When prompted press lt Esc gt to Enter Monitor At the Monitor prompt enter B lt Enter gt to boot the system into RMX Enter super lt Enter gt at the login prompt Enter passme lt Enter gt at the password prompt Insert the Starlink V4 floppy At the RMX prompt enter LOADSUPP lt Enter gt oT DS Ee ee
12. eNTEGRA P amp R Service Manual 6 26 Rev 5 Direction 2263784 100 June 17 2001 Software Installation Installing eNTEGRA Software Options and Licenses 6 4 Installing eNTEGRA Software Options and Licenses This section explains how to install additional software options and the required licences as follows e Installing the licenses Section 6 4 1 on page 6 27 e Installing OSI Software required for communication with StarCam and SPX systems Section 6 4 2 on page 6 29 6 4 1 Installing the Licences Application licences are generated per each unique activator ID eNTEGRA Release 1 0 includes individual licence for each licensed option To install licences 1 Sra we Se Yb Insert the Licences diskette supplied with the system into the floppy drive and attach the Activator onto the parallel port on the back panel of the computer Double click My Computer icon on the Desktop Double click 31 2 Floppy A Select all the files by pressing lt Ctrl gt lt A gt simultaneously Drop down the Edit menu and select the Copy entry Double click on My Computer icon on the desktop Browse to D Einstein Licences Drop down the Edit menu and select the Paste entry eNTEGRA P amp R Service Manual 6 27 Rev 5 Direction 2263784 100 June 17 2001 Software Installation Installing eNTEGRA Software Options and Licenses Table 6 1 lists the software options available on eNTEGRA Release 1 0X along w
13. page 6 20 InSite Installation on page 6 21 Installing eNTEGRA Software Options and Licenses on page 6 27 Configuring the system as per Section 3 8 on page 3 14 Configuring the Network as per Section 3 9 on page 3 28 Configuring the Hardcopy Devices as per Section 3 10 on page 3 33 Performing the Functional Checks detailed in Chapter 4 eNTEGRA P amp R Service Manual 6 3 Rev 5 Direction 2263784 100 June 17 2001 Software Installation Software Load From Cold For Dell OptiPlex GX200 6 2 2 Disconnecting Existing Optical Disk Drives if Applicable l 2 3 Shutdown eNTEGRA and the computer if needed Remove the computer cover referring to your PC Guide Disconnect the DC power cable and the SCSI flat cable from the optical drive Reassemble the computer cover 6 2 3 Setting the System BIOS 1 Turn ON the computer 2 When the Dell screen appears press lt F2 gt as prompted on the upper right corner of the screen Scroll to the Boot Sequence entry and press lt Enter gt 4 Use the down arrow key to highlight IDE CD ROM Device and then move it to the first line in the dialog using the lt gt lt gt key on the numeric keypad 5 Press lt Esc gt to close the dialog 6 Verify Primary Drive 0 OFF Primary Drive 1 OFF Secondary Device 0 ON Secondary Device 1 OFF 7 Press lt Esc gt Select Save Changes and Exit and press lt Enter gt 9 Proceed to Installing the W
14. 7 Type in the eNTEGRA s hostname for the Name for example eNTEGRA entegra lt Enter gt The system responds with Name codonics username entegra 331 Use printer 0 2 8 9 10 11 99 100 104 for password Password 8 Type in 0 for the password The password will not be echoed 0 lt Enter gt The system responds with 230 User entegra logged in on System Device ftp gt 9 At the ftp gt prompt type the following to set file transfer to binary bin lt Enter gt The system responds with 200 Type set to I ftp gt 10 Type the following to transfer the codon set file to the Codonics put codon set lt Enter gt The system should respond with a message indicating the file was trans ferred 11 Type the following to quit the ftp session quit lt Enter gt 12 Open the eNTEGRA icon and send an image to the Codonics 13 Analyze the image If further adjustments are required change the GAMMA and MCM values in the codon set file on eNTEGRA and resent it to the Codonics Repeat as necessary eNTEGRA P amp R Service Manual 3 76 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options 3 10 9 PostScript Compatible Printer Installation Configuration 3 10 9 1 Overview This section provides general information on interfacing a PostScript compatible printer to the eNTEGRA system The eNTEGRA application utilizes the Window NT system services to send printouts to any supported printer device
15. Click the OSI tab Click Add Type in the Remote Station Name Select the type from the drop down list Starcam SP or GENIE eNTEGRA Type in the Ethernet address of the remote station Click OK three times to close the ENTEGRA Configuration window Click Apply to exit User Preferences window For the changes to take affect shutdown and reactivate the eNTEGRA application eNTEGRA P amp R Service Manual 3 18 Rev 5 Direction 2263784 100 June 17 2001 Installation Site Configuration 3 8 4 6 DICOM Configuration 1 Click the eNTEGRA icon on the Task Bar 2 Click the Configuration button on the upper left corner of the Main screen then click Advanced Configuration Click the Dicom tab 4 For each remote station with which the system is to communicate via DICOM refer to Table 3 12 for DICOM configuration parameters a Click the Add button b Type in the Host name Application Entity and IP address of the Remote station c Verify that the appropriate flags are checked to enable the correspond ing operations d Click the OK button 5 When all remote DICOM stations have been added click the OK button to close the ENTEGRA Configuration window Not DICOM printers are not configured during this step The DICOM print Application a Entity AE is separate from the DICOM image transfer AE DICOM printing is configured during the hardcopy configuration 6 Click Apply t
16. Formatting Drive D as NTFS C 12 Formatting Drive D as NTFS 1 Double click on the Start button in the Task Bar and select Programs Administrative Tools common Disk Administrator 2 Click OK 3 Inthe Disk Administrator dialog click right on the letter assigned to the CD ROM and select Assign Driver Letter From the Assign drive letter drop down list select E and click OK 5 In the confirm window click Yes 6 In the Disk Administrator dialog click right on Free Space and in the pop up window click Create When asked click Yes OK and Yes 8 In the Disk Administrator dialog select Exit from the Partition drop 16 lig 18 down menu When asked click Yes to save the partition then click OK twice 10 11 12 13 14 15 Double click on My Computer icon located on the desktop Right click on D drive icon Select the Format entry Click the down arrow in the File System field and select NTFS entry Click the Start button The following warning will be displayed WARNING formatting will erase all data on this disk Select OK to format the disk Cancel to abort Click OK The disk will be formatted Upon system prompt Format Complete click OK Click Close Proceed to Installing the eNTEGRA Application and Its Accessory Components on page C 16 eNTEGRA P amp R Service Manual 15 Rev 5 Direction 2263784 100 June 17 2001 In
17. In the eNTEGRA Application installation click Next Next Next When asked click the radio button next to the applicable language then click Next Next If requested replace the eNTEGRA Application CD with the eNTEGRA On line Help CD Otherwise skip to step 22 below Click Next Next and then Finish eNTEGRA P amp R Service Manual 17 Rev 5 Direction 2263784 100 June 17 2001 Appendix C Software Installation on Dell Precision 610 C 1 Overview This appendix provides detailed instructions for installing the basic software of the eNTEGRA system on the Dell precision 610 computer referred to as software load from cold For software load from warm and for installing the eNTEGRA software options and licences refer to the related sections in Chapter 6 Software load from cold is used when the hard disk is corrupted or replaced and the entire package must be installed from scratch CAUTION A Load from cold is a destructive procedure and all the data on the disk will be lost Verify that all patient data is backed up Back up the Archive Log Index directory C ArcLog before starting the software load from cold procedure C 1 1 Time Required The time required to complete the installation of the basic software is 1 5 hours about 90 minutes eNTEGRA P amp R Service Manual 1 Rev 5 Direction 2263784 100 June 17 2001 Overview C 1 2 Procedure Overview The load
18. Refer to Chapter 5 Section 5 1 3 1 for pinout details on the DASM LCAM eNTEGRA P amp R Service Manual Direction 2263784 100 3 37 Rev 5 June 17 2001 Installation Hardcopy Options b Interface Configuration The Imation Lasercamera must be configured to communicate with the eNTEGRA Table 3 15 summarizes the configuration parameters required for the components in the DASM LCAM to Imation Lasercamera interface chain Note Refer to the Imation 3M Service Manual or Service Representative for details Table 3 15 DASM LCAM Imation Lasercamera Interface Configuration Device Parameter Setting Jumper Input Module Baud Rate 1200 Communication Parameters Stop Bits 1 Data Bits 8 Parity Even Parity Enable Enable Character Pacing 0 End Of Message CR Protocol ACK NACK Memory Full Resp BSY Command Set 959 Image Size New Alarm Mode New P1 P6 0 eNTEGRA P amp R Service Manual 3 38 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options Table 3 15 DASM LCAM Imation Lasercamera Interface Configuration Continued Device Parameter Setting Input Module EIB Type Digital PISTOM PANEIS Parameter Set Set 0 OEM GE Modality Nuclear Dual Switch Off Memory Width 9 Pixel Width 8 Requeue Number 3 Media Destination OM0 OM1 Enlarge Format Yes
19. The system responds with With the Startup floppy in the drive type L to LOAD followed by RETURN E to Exit followed by RETURN 9 Enter L lt Enter gt The system responds with Not the correct Startup Floppy Insert any floppy and enter L to LOAD followed by RETURN E to Exit followed by RETURN 10 Enter L lt Enter gt The system responds with SL4 Starlink Supplement V1 O K 11 Remove Starlink V4 floppy 12 Enter sh lt Enter gt to shut system down 13 Reboot the system to Starcam by pressing the RESET button 14 Enter ZSCF 7 lt Sendform gt to list software present 15 Verify that the Starlink option is present and that the version is at 4 0 16 Add the eNTEGRA workstation to the Starlink Configuration file via the NAST command Refer to Section 3 9 3 to get the eNTEGRA s Ethernet LAN address eNTEGRA P amp R Service Manual 3 30 Rev 5 Direction 2263784 100 June 17 2001 Installation Remote LAN Configuration 3 9 5 Starlink Version 3 Upgrade for Starcam Build Standard 0 1 N oO L Soe E gt 10 11 12 13 14 15 16 17 18 19 Shut down the Starcam system by entering shutdown lt Sendform gt Reboot the system by pressing the following keys together lt Ctrl gt RIGHT lt Shift gt lt Q gt When prompted press lt Esc gt to Enter Monitor At the Monitor prompt enter B lt Enter gt to reboot system into RMX At the RMX prompt enter LOADOPT lt Enter
20. 1 2 Open the eNTEGRA Application Click the Configuration button on the upper left corner of the Main screen then click Advanced Configuration 3 Click the General tab Overtype the default Institution ID according to the Site Assignment Matrix Click OK to close the ENTEGRA Configuration window Click Apply to exit User Preferences window Shutdown the eNTEGRA application and restart it Verify that the institution ID was updated successfully 3 8 4 2 Change Default Computer Name 1 Note 7 Click on the minimize button on the upper left corner of the Main Screen to view the system s Desktop Right click the Network Neighborhood icon located on the Desktop and select the Properties entry In the Identification tab click the Change button Overwrite the default computer name by the new host name and click the OK button The name is limited to 17 characters A Z a z 0 9 and _ Server licenses depend on the computer name eNTEGRA P amp R Service Manual 3 16 Rev 5 Direction 2263784 100 June 17 2001 Installation Site Configuration 3 8 4 3 Updating the Regional Settings 1 5 Click left on the Start icon on the Task Bar and select Setting gt Control Panel On the Control Panel window double click on the Regional Settings icon In the Regional Settings tab select the relevant language and country In the Date tab select the Short Date St
21. 8 9 In the Select Components to Install dialog verify that ONLY the ADI component is checked and click OK In the Type of Addressing window click OK to use the default ICAD format 10 In IMPART 32 Installation Complete click OK 11 Click No to avoid rebooting the system 12 Close all windows 6 4 2 4 Installing a Patch for ADI 1 2 3 Move to the patch installation directory E OSI BJ_Patch Run BJ_Patch bat Reboot the system If necessary shut down the eNTEGRA application and stop the servers 6 4 2 5 Configuring the eNTEGRA on Remote OSI Stations Refer to Section 3 9 After the eNTEGRA system has been configured on all the remote OSI stations log into eNTEGRA and verify communication with the StarLink and SP based systems eNTEGRA P amp R Service Manual 6 31 Rev 5 Direction 2263784 100 June 17 2001 Chapter 7 System Upgrade This chapter provides instruction for hardware upgrades as follows e Section 7 1 Adding an Optical Drive on page 7 1 For upgrading eNTEGRA software version please refer to Section 6 3 Software Load from Warm on page 6 26 For adding clinical application licences please refer to the procedure described in 6 4 1 Installing the Licences on page 6 27 7 1 Adding an Optical Drive 7 1 1 Installing Archive Optical Disk in PC Tower 1 Power down the PC 2 Remove the PC cover Refer to the PC User s Guide 3 Set SCSI ID of the
22. C The ideal environment for the system is 24 C and 40 60 relative humidity 15 Inform the customer about GE s maintenance procedure and schedule the next Planned Maintenance eNTEGRA P amp R Service Manual 1 2 Rev 5 Direction 2263784 100 June 17 2001 Safety Guidelines and Regulatory Hazards 1 2 Hazards 1 2 1 General Hazards 1 Some repair replacement procedures require the removal of protective covers exposing parts at high temperatures or with pinch points Read the safety warning labels and follow the instructions in this Service Manual to prevent burns or injuries 1 2 2 Electrical Hazards 1 Do not remove or open system covers or plugs while the unit is powered ON Some internal circuits operate at high voltage capable of causing severe electric shock and or serious injury 2 You must be watchful for any short circuits in the system this is especially important if any fuse is blown or there are circuit breakers that won t reset CAUTION A Conductive fluids that seep into the active circuit components of the system may cause short circuits resulting in electrical fires 1 3 Electrical Precautions 1 Verify with hospital engineering department that the designated power line is stable If any doubt connect a line recorder for 24 hours at least 2 Whenever handling electrostatic devices or circuit boards use a grounding strap and wrist band This grounding strap and wrist band
23. Input Module Parity Enable Enable Digital EIB Parameters Test Pattern No Header Mode Header Prescale On Timeout 20 Request Hold 200 Request Inactive 255 Retransmit Setup 255 Pixels Line 1024 Image Lines 1024 Pixel Width 8 Parity Even Port Port 0 UKEIB RS232 RS422 Select Jumper RS422 DEIB Fiber Optic Clock Rate 10 MHz Jumper eNTEGRA P amp R Service Manual 3 39 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options 3 10 2 5 Image Quality Configuration Note The 952 command set provides control over a number of image quality parameters for the Imation Lasercameras These parameters are set by either the eNTEGRA hardcopy server via the HCdefaults win32 file or set at the Lasercamera s input module Table 3 16 provides a summary of these parameters The HCdefaults win32 setting will over ride the input modules setting Table 3 16 Imation Lasercamera Image Quality Parameters Parameter ios Name in Description HCdefaults win32 Remarks tables black on white In HCdefaults win32 a setting of D causes the Lasercamera to use the setting on the input module Contrast Table Specifies a contrast table to use to produce the Prn3m 952 fmt n contrasts Each format and image The range of the contrast table settings each zone has a are 1 to 30 Table 1 to 15 represent positive separate contrast tables white on black and 16 to 30 negative line Density Specifies
24. Prn3m 952 12 4 width 024 Prn3m 952 12 4 height 024 Prnom 952 12 4 contrasts D D D lt dit to change Contrast 12x1 Prnsm 952 12 4 1ines Prn3m 952 12 4 bdr lines 32 Prn3m 952 12 4 hmag 0 Prn3m 952 12 4 vmag 0 Prn3m 952 12 4 hmode 5 Prn3m 952 12 4 vmode 5 format 16 Prn3m 952 16 desc 6 on 1 4 frames on each of 4 zones Prn3m 952 16 zones 4 zone 1 Prn3m 952 16 1 frames 4 Prn3m 952 16 1 width 024 Prn3m 952 16 1 height 024 Prn3m 952 16 1 contrasts D D D Edit to change Contrast 16x1 Prn3m 952 16 1 lines 200 Prn3m 952 16 1 bdr lines 32 Prn3m 952 16 1 hmag 0 Prn3m 952 16 1 vmag 0 Prn3m 952 16 1 hmode 5 Prn3m 952 16 1 vmode 5 Figure 3 8 HCdefaults win32 952 Lasercamera Section Part 4 eNTEGRA P amp R Service Manual Direction 2263784 100 3 44 Rev 5 June 17 2001 Installation Hardcopy Options zone 2 Prn3m 952 16 2 frames 4 Prn3m 952 16 2 width 1024 Prn3m 952 16 2 height 1024 ee eee seen eee D D D Di 4dit to change Contrast 16x1 rn3m 952 16 2 fines t200 Prn3m 952 16 2 bdr lines 32 Prn3m 952 16 2 hmag 0 Prn3m 952 16 2 vmag 0 Prn3m 952 16 2 hmode 15 Prn3m 952 16 2 vmode 15 zone 3 Prn3m 952 16 3 frames 4 Prn3m 952 16 3 width 1024 Prn3m 952 16 3 height 1024 Prn3m 952 16 3 contrasts D D D D lt Edit to change Contrast
25. and Yes In the Disk Administrator dialog select Exit from the Partition drop down menu When asked click Yes to save the partition then click OK twice Double click on My Computer icon located on the desktop Right click on D drive icon Select the Format entry Click the down arrow in the File System field and select NTFS entry Click the Start button The following warning will be displayed WARNING formatting will erase all data on this disk Select OK to format the disk Cancel to abort Click OK The disk will be formatted Upon system prompt Format Complete click OK Click Close Proceed to Installing the eNTEGRA Application and Its Accessory Components on page 6 20 eNTEGRA P amp R Service Manual 6 19 Rev 5 Direction 2263784 100 June 17 2001 Software Installation Software Load From Cold For Dell OptiPlex GX200 6 2 15 Installing the eNTEGRA Application and Its Accessory Components ON Se e 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Insert the eNTEGRA CD ROM to the CD ROM drive Double click on My computer icon located on the desktop Double click the E drive CD ROM Drive Double click Install vbs Click on OK When prompted insert the licences diskette into the floppy drive and click OK Click Yes and wait for the installation of the HASP Device Driver Setup program to complete On the Warning window displayed
26. as follows i Select any study ii Click the Archive button on the Archive panel iii In the opened warning click Yes All the system Review Templates will be stored under patient CORRECTIONS DIRECTORY If you have any User Protocols which you want to transfer to eNTEGRA back them up to the optical disk as follows a b Activate the Aladdin Archive application from within the Housekeeping category From the Aladdin Archive Processing screen click on the required database listed in the Select a Database panel on the left The name of the currently selected database is displayed Click on the Save a Script button For each user protocol to be transferred to eNTEGRA i Select the required protocol listed under Save a Protocol in the Protocol Archive dialog box ii Click on the OK button The message Saving appears in the upper left corner of the tab card When save is completed the message Save Completed appears in the upper left corner of the tab card The database where the protocol was saved and the protocol name s are listed on the processing screen Each protocol saved is shown as a dataset within the Aladdin Protocols study If the protocol was already archived a message box is opened indicating that an extension will be added to avoid confusion and providing the new name for example LungHeart_0 eNTEGRA P amp R Service Manual Direction 2263784 100 2 Rev 5 June 17 2001
27. click Yes to continue with the setup program In the HASP Device Driver status dialog click Next In the Setup Option window click Typical In the Confirm Your Selection window click Next When the message The HASP Device Driver has been successfully installed appears click OK Finish In the Acrobat installation click Next Next Select No when asked to reboot From the eNTEGRA CD double click eENTEGRA_LFC vbs In the QGS installation click Next Finish In the Demo Database installation click Next Next Next and then Finish In the ENTEGRA Application installation click Next Next Next When asked click the radio button next to the applicable language then click Next Next If requested replace the eNTEGRA Application CD with the eNTEGRA On line Help CD Otherwise skip to step 22 below Click Next Next and then Finish If the system includes an optical drive reconnect it as per Adding an Optical Drive on page 7 1 Proceed to InSite Installation on page 6 21 eNTEGRA P amp R Service Manual 6 20 Rev 5 Direction 2263784 100 June 17 2001 Software Installation Software Load From Cold For Dell OptiPlex GX200 6 2 16 InSite Installation Note InSite installation consists of the following steps to be performed in theh given irder e Installation of the Command Line Telnet on page 6 21 e Configuring ATAMAN Telnet to include eN
28. drive CD ROM Drive gt Drivers DELLGX200_DRIVERS exe When the system prompts Extracting completed click OK Click with the right mouse button on the Network Neighborhood icon on the desktop Click on the Properties entry Click Yes to confirm that networking is to be installed Click Next Click on Select From List In the Select Network Adapter window click on Have Disk Type in the path C Drivers 3Com Click OK twice Click Next 4 times Remove the eNTEGRA CD and insert the Windows NT CD wait for the Windows NT CD to open and close it In the Windows NT Setup window type in the path D and click Continue Upon the message If there is a DHCP click NO In the opened Microsoft TCP IP Properties window click the IP Address tab and a Type in your IP address as defined in the pre installation checklist b If relevant type in your Subnet Mask If relevant type in your Default Gateway address as defined in the pre installation checklist If relevant click the DNS tab and type in the DNS IP address defined in the pre installation checklist If relevant click the WINS tab type in the Windows Server primary and secondary IP addresses defined in the pre installation checklist Click OK at the bottom of the page Upon system prompts click Next Next Next and Finish When queried to shutdown remove the Windows NT CD from the drive and cli
29. hazard may exist which will or can cause minor personal injury or property damage if the instructions are ignored eNTEGRA P amp R Service Manual 1 4 Rev 5 Direction 2263784 100 June 17 2001 Safety Guidelines and Regulatory IEC Symbols 1 6 IEC Symbols The system may have labels with one or more of the following symbols These symbols indicate the IEC standards to which the system conforms Table 1 1 IEC Symbols IEC Standard Alternating Current Protective Earthing Point ON Power OFF Power OFF Input Power Output Power Functional Earth Ground Warning Caution consult accompanying documents Electrical Shock Hazard SP P ob0 c eNTEGRA P amp R Service Manual 1 5 Rev 5 Direction 2263784 100 June 17 2001 Safety Guidelines and Regulatory Regulatory Information 1 7 Regulatory Information 1 7 1 Standard Compliance The equipment complies with the following standards IEC 601 1 Medical Electrical Equipment General Requirements for Safety EN60601 1 2 Medical Electrical Equipment Electro Magnetic Compatibility Requirements and Tests This equipment generates and can radiate radio frequency energy The equipment may cause radio frequency interference to other medical and non medical devices and to radio communications To provide reasonable protection against such interference the system complies with the emission limits for a Gr
30. site_name and organization_name and click Next 4 Inthe Registration window type in your product_ID recorded on the provided manual and click Next 5 When prompted type in your computer name as defined in the pre installation checklist and click Next 6 When prompted type in your password as defined in the pre installation checklist the following description will use the password elgems 7 Retype the password and click Next 8 When prompted select no do not create an emergency repair disk and click Next 9 In the opened Windows NT Components dialog select Install the most common components and click Next 10 Upon the message Installing Windows NT networking click Next 11 Check Do not connect this computer to a network at this time and click Next 12 Click Finish to finish setup 13 In the opened Date Time Properties window a Set the appropriate date and time in the Date amp Time page b Click the Time Zone tab click on the down arrow to display the Time Zone list select the appropriate Time Zone and click OK c Click Close 14 If the system finds the video adapter click OK then click Cancel for Video card driver installation which will be installed later as described in the next section Procedure Overview on page C 8 As long as the display driver is not installed an Invalid Display Settings error Note message will be displayed aft
31. 17 2001 Installation Site Configuration 3 8 Site Configuration 3 8 1 Introduction The eNTEGRA system comes pre loaded with the WINDOWS NT operating system ENTEGRA Application software and all licenses The following local parameters will need to be configured for the site Institute ID Local IP Address Regional Settings Site Name Starlink Configuration Table DICOM Configuration Remote Database Option Remote Connectivity Option Hardcopy Server and Devices Archive Server GE CARES MUST ID Modem IP Addresses at least two This section details how to configure these parameters Important StarLink on the NT Platform requires the OSI Software Option StarLink will not work without this option To verify if this option has been loaded on the system e Click on the Start icon on the Tasks Bar and select Settings Control Panel e Double click the Network icon e Go to the Protocols tab and check if IMPART ISO 8073 Transport is installed 3 8 2 Required Information Before starting this procedure you must have the System Assignment information collected during site preparation available This includes Hospital ID that will appear on the eNTEGRA screen up to 2 lines IP Address of the local eNTEGRA system How customer wants Site Name listed on ENTEGRA Ethernet Addresses of all systems on the Starlink LAN Starcams M Link system and Starlink agent systems Ethernet Addresses of all SP sys
32. 2001 Chapter 8 Troubleshooting and Repair 8 1 Philosophy The general repair philosophy for the eNTEGRA workstation and its Field Replaceable Unit FRU is to repair at a UNIT level for both hardware and software The product has been configured and structured to conform to standard FRU policies and to utilize as many common parts as possible A troubleshooting guide embedded InSite and internal diagnostics allow fault isolation to the FRU level In the Workstation no internal components are exchanged with all repairs being performed by the OEM vendor Training is structured to support this philosophy and develop a basic working knowledge of the Windows NT environment as required for software and Network troubleshooting This chapter is divided in to two main areas e Troubleshooting Section 8 2 e Replacement Procedures Section 8 3 eNTEGRA P amp R Service Manual 8 1 Rev 5 Direction 2263784 100 June 17 2001 Troubleshooting and Repair Troubleshooting 8 2 Troubleshooting This section provides instructions for Operating System Installation Problems on page 8 3 eNTEGRA Installation Problems on page 8 3 Post Installation Problems on page 8 4 Communication Problems on page 8 4 Communication Problems on page 8 4 Printing Problems on page 8 5 Codonics Status Check on page 8 6 Releasing the System When it Gets Stuck on page 8 7 Restoring Pervious Configuration on page 8 7 Creating Problem Reports
33. 2001 Installation Site Configuration 3 8 4 11 Hardcopy Configuration 1 Click the Configuration button on the upper left corner of the Main screen then click Advanced Configuration Click the Printers tab 3 Click the Add button In the Add Edit Printer Device window refer Table 3 11 to for supported hardcopy devices Type in the alias name of the hardcopy device Select the type of the hardcopy device from the drop down list Click Setup Type in or select the required information for the specific hardcopy device e Click OK to close the Printer Setup window ao fF To define an additional Hardcopy Device repeat steps 3 amp 4 When all the hardcopy devices have been defined Select the default Printer from the Drop down list Click OK to close the ENTEGRA Configuration window 8 Click Apply to exit the User Preferences window eNTEGRA P amp R Service Manual 3 26 Rev 5 Direction 2263784 100 June 17 2001 Installation Site Configuration Note Important Table 3 11 Valid Device Type Settings Additional Hardcopy Device Interface Device Type Configuration Details Imation 8M Lasercamera DASM LCAM 3M Section 3 10 2 952 959 969 or DryView Kodak Lasercamera DASM LCAM 3M Section 3 10 3 XLP100 1120 2180 DuPont Lasercamera DASM LCAM dupont_3m Section 3 10 4 Fuji Lasercamera DASM LCAM 3M Section 3 1
34. 3 10 4 DuPont Lasercameras Conf gurao sis sssdscnisveccsasesesnsarvianiasasiiernciaass 3 54 3 10 4 1 VETVE soii A A A 3 54 3 10 4 2 Eais Fe eee a 3 55 3 10 4 3 Lasercamera a ec cee ee een 3 56 3 10 4 4 Image Quality Configuration iseseisana 3 57 2403 Fuji Laser Cameras a ceca 3 58 3 10 5 1 OWI W urena i 3 58 21032 Basie Preotii en TR 3 59 3 105 3 Lasercamera COnnet oN carreri or ree ewe 3 60 3 10 5 4 Tree i a eo oe es 3 61 3 105 535 Image Quality Configuration ossosa 3 61 3 10 6 Konica Lasercameras ConfigUratION ssscicsastsinacsicisciermanneeuonias 3 62 3 10 6 1 CI N a 3 62 3 10 6 2 Pasie Procedir cidade 3 63 3 10 6 3 UN I EN 3 64 3 10 6 4 Image Quality Sr eases recente aR 3 65 3 10 7 Polaroid Helios Lasercamera Installation Configuration e00 3 66 3 10 7 1 I IEE OE E E A nero 3 66 3 10 7 2 Pasie Pooc iiit ansnasonannananana e aa 3 67 Kn a EA a Se cine a eines 3 68 3 10 7 4 BRUTE Oe cic acis osteeanonoaeoeenoesanacen 3 69 3 10 8 Codonics NP1600M Color Printer Installation Configuration 3 71 3 10 8 1 ee een ee eee 3 71 3 10 8 2 Basie Procedo E 3 72 3 10 8 3 Poner MEN a 3 73 3 10 8 4 Codonics Uperid ssscnconsniicnnenai danni 3 74 3 10 8 5 Pee Onalty Configuration sesen aoe es 3 75 3 10 9 PostScript Compatible Printer Installation Configuration 3 77 3 10 9 1 De oa asn coe ee sas sass eaneiccs N 3 77 3 10 9 2 Base Pro wi Hi demas 3 77 3 10 9 3 Physical Tere a eoecacsctcerniiees Caen 3 80 3 10
35. 36 vR oLD MALE 9 578 Pava D 578 Paua D 578 Pava Ba 5 8 1131 w D A 3 attenuat D a5 Bone we D a 9 Brain sp E aBNorMaL PaT 0 ad sc BONE GATES RENAL 1537 4438 9984 6231 OPT98AC1 MPR98116 NG98114 QUANTEN EX 2 616114 Aladdin Prot ALADDIN INTERFILE B archive E Archive STATIC D Aspiness sT Cardial 45 no descript B Normacizep G NORMALIZED TOHO eNTEGRA ENT SELEC GATES RENAL GALLIUM WB WB BONE WB SCAN INDIUM WB SCAN 1131 TWO DAY BONE TOHO BRAIN TOMO MAG3_RENAL BONE TOMO ALLADIN STATIC BO ECT PLANAR 3 20 89 7 22 99 7 21 99 4 6 99 7 19 99 7 29 97 16 36 96 4 8 98 10 9 92 1 29 98 16 9 92 9 3 97 15 11 1624 x 21 1 4 13 94 4 13 94 14 18 64 x 64 68 BILIARY TEST DATA 1 DISIDA 9 9 92 no descript STATIC Copied Image B BILIaRv2 STATIC Gi BILIARY2 sBILIaryY3 OD BILIARY 2 cerLow STATIC STATIC DYNAMIC Patient Selector Buttons Aladdin Programming STATIC STATIC STATIC 9 9 92 13 45 128 x 128 1 9 9 92 13 45 9 9 92 13 45 11 15 90 18 09 x Pny AF box C jx 08 02 Jan 01 K General SPECT w Cardiac Renal VZ Bone F Oncology amp Infection Miscellaneous Biliary Review _Qverview_ User Notes Main Screen Panel Tabs Load Data Figure 3 3 eNTEGRA Main Screen eNTEGRA P amp R Service Manual Direction 2263784 100 3 13 Rev 5 June
36. 47 Click OK 48 In the opened Welcome window click Close 49 Proceed to Installing Service Pack 6a on page 6 10 eNTEGRA P amp R Service Manual Direction 2263784 100 6 9 Rev 5 June 17 2001 Software Installation Software Load From Cold For Dell OptiPlex GX200 6 2 6 Installing Service Pack 6a This installation depends on the language being used 1 For English version Insert the eNTEGRA Application CD into the CD Drive and double click the My Computer icon located on the desktop For other languages Insert the eNTEGRA Accessories Software CD into the CD Drive and double click the My Computer icon located on the desktop Double click the D drive CD ROM Drive 3 Double click the SP6 directory 5 6 7 8 9 For the English version skip to step 5 below For other languages double click the applicable language directory Double click SP6ai386 exe Check the Accept License Agreement box if requested Uncheck Backup files necessary to uninstall service pack Click Install When prompted click on Restart to reboot the system and logon as before 10 Proceed to Installing the Display Driver on page 6 11 eNTEGRA P amp R Service Manual 6 10 Rev 5 Direction 2263784 100 June 17 2001 Software Installation Software Load From Cold For Dell OptiPlex GX200 6 2 7 Installing the Display Driver 1 When prompted press lt Alt gt lt Ctrl gt lt Del gt a
37. 8 3 2 3 Time Required This repair takes approximately 2 5 hours to complete 8 3 2 4 Procedure 1 Power down the GENIE 2 Remove the defective hard drive from PC Refer to How to Install Accessories section of the PC User s Guide 3 Install the replacement hard drive in to the PC Refer to How to Install Accessories section of the PC User s Guide 4 Power up the processor unit and perform Software Load from Warm described on page 6 26 5 Verify proper operations 6 Return the defective processor unit in the replacement unit s packaging eNTEGRA P amp R Service Manual 8 10 Rev 5 Direction 2263784 100 June 17 2001 Chapter 9 Renewal Parts The renewal parts are classified in three groups e Hardware on page 9 1 e Software on page 9 2 Documentation on page 9 3 9 1 Hardware Table 9 1 and provides a list of the eNTEGRA hardware FRUs To identify the components please refer to Figure 5 1 on page 5 2 Table 9 1 Hardware FRU List er ELGEMS GEMS FRU Descripuen Part Number Part Number code moles Dell OptiPlex GX200 replacing the Dell DTP000119 1 Precision 610 and the Kayak XU Pentium III 3Com Ethernet Card 3C905B TX CP001133906 1 Applicable only for Dell Precision and HP Kayak computers Can be replaced by 3C905C TX CP001100024 SCSI IIl to SCIS II Adapter Cable CBL000875 2 SCSI Flat Cable CBL000939 2 Sony Monitor 2
38. B 14 B 12 era ie the FTF ete ek eee ener cae B 15 B 13 Formatting Diye Dras NTFS aerun E B 16 B 14 Installing the eNTEGRA Application and Its Accessory Components B 17 Appendix C Software Installation on Dell Precision 610 ccssoees C 1 CA RPP sen E O aie C 1 Gli Time Roir san eae eneeanomaeens C 1 Cle Procedure EIEN siiccusuncinnicumemanamineumaee wenn C 2 C2 Installing the Windows NT Operating System seseseeeeeseeeeesererrerrrereesrseee C 3 C 3 Installing Windows NT Networking eeseseseeseesessseererseesrrsereseesseseresresseserss C 5 C4 lostalling Service Pack Giresse a C 8 C3 Installing the Display DiV r ersen a A C 8 C 6 Adjusting the Display Properties unceeesoae eee C 9 CT Tostalline the Sound DAVEE srsirensnr tians araa ambi C 10 C 8 Setting Syst m OPTOG acsissinrikipnsi enn Eeka ELEns nore TE Ek PELENE EETAS KEEN ENA C 10 C 8 1 Sene Me Date FO cient C 11 C 8 2 Setting the Application Event Viewer LoggingS cessceeseeseseeeeeees C 11 C 8 3 Setting the Task Bar Pt icssascscecicccticee ee Seis C 11 C 8 4 Som the Virmal ei cer ceo C 11 C 8 5 Setting the View ONS iisccicissicntcasasicerasinnuteisinnaetaaasateansidalauiaiasaiacaiais C 12 Co Installing Internet EX DIOCEr F tierce renee C 12 C 10 Installing RAS Modem and TCP IP for Printing seeen C 13 C 11 Tia i FLF ei ee eee C 14 Ciz Formatting Dove Dras NTE S cerron a R C 15 CAS Installing the eNTEGRA Application and Its Accessory Components
39. CEqual Quantification button is enabled Drop down the File menu and select the Quit entry to quit the protocol eNTEGRA P amp R Service Manual 4 3 Rev 5 Direction 2263784 100 June 17 2001 Functional Checks Processing Validation 4 2 2 Running an Application For systems with ECToolbox or Cequal Light license the application has been run above Only for systems that do not have an ECToolbox or CEqual Light license run the Cardiac SPECT application as follows 1 2 Select a gated rest or stress planar dataset form the patient database Click the Cardiac SPECT icon residing in the Cardiac Category on the Processing tab 3 Click the Start Cardiac SPECT button 10 11 12 13 Click the available button on the Recon tab Rest Data Only or Stress Data Only whichever matches your selected input data If necessary adjust the Windowing tool for better view of the heart in the Rest Stress Planar Image displayed If necessary move the central marker to display the left ventricle in the Rest Stress Live Image Set the reconstruction limits on the Planar Image displayed Click Proceed on the control area When the VLA HAL and SA obliques have been created click the Back button on the control area Click the Stress Gated Data Only or Rest Gated Data Only whichever applies to the input data When the control area displays the prompt Proceed with Current Gated Recon Filters
40. Codonics Users Manual and Section 3 10 8 3 Upgrade the Codonics as per Section 3 10 8 4 Log into eNTEGRA select the Formatter Static image from the Default Patient Calibration study and click the New icon located on the Patient Selector Control Bar Click the Camera tool in the Display Screen Click the Down Arrow in the Film dialog select the Codonics Lasercamera and click Submit If a No image is printed refer to Section 8 2 for details on troubleshoot ing b An image is printed analyze the image and determine if additional adjustments are required Create a text file that contains the Codonics image parameters on the eNTEGRA then send it to the Codonics Refer to the Codonics Users Manual and Section 3 10 8 5 Repeat steps 5 through 7 until optimal film quality is achieved eNTEGRA P amp R Service Manual 3 72 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options 3 10 8 3 Printer Interface This section provides details on how to interface the Codonics Printer to the eNTEGRA system via the LAN a Interface Wiring Figure 3 17 and Table 3 29 detail the interface between the eNTEGRA and the Codonics Codonics 10 100 Base T HUB Figure 3 17 eNTEGRA to Codonics Interconnection Table 3 29 Codonics Network Interface Cable Cable Ru
41. Display Driver amp Adjusting the Display B 5 Installing the Display Driver amp Adjusting the Display The display card for the HP Kayak Xeon is Millennium G200 To install the Millennium G200 driver and adjust the display ee Me ee be a e e e eS A U N O 15 16 17 18 19 20 21 22 24 25 26 Ensure that the eNTEGRA CD is inserted into the CD drive Click the Right mouse button on an empty place on the desktop In the opened menu select the Properties entry In the Display Properties window click the Settings tab Click the Display Type button Click Change button Click on the Have Disk button Type in the path D drivers Matrox and click OK Select Matrox Graphics Millennium g200 Click OK YES OK Close the Display Type window Close the Display Properties window Click YES to restart the computer When prompted press lt Alt gt lt Ctrl gt lt Del gt and login into the system with Username entegra Password entegra Click the with the Right mouse button on an empty place on the desktop In the opened menu select the Properties entry In the Display Properties window click the Settings tab Click the down arrow under the Color Palette and select True Color Move the slider in the Desktop Area to display a resolution of 1280 by 1024 pixels Click the down arrow under Font Size and select Small Fonts Click the down arrow under Refre
42. For other languages double click the applicable language Double click the IE5 directory Double click install bat When installation has been completed the system will reboot Proceed to Setting the View Options on page C 13 eNTEGRA P amp R Service Manual 12 Rev 5 Direction 2263784 100 June 17 2001 Installing RAS Modem and TCP IP for Printing C 10 Installing RAS Modem and TCP IP for Printing Installation of the Remote Access Service RAS is required for DICOM Part 10 1 When the system comes up press lt Alt gt lt Ctrl gt lt Del gt and login into the system with Username entegra Password entegra 2 Click OK 3 Insert the Windows NT Workstation CD ROM and close the opened 10 11 12 13 14 15 16 17 18 Windows CD window Click right on the Network Neighborhood icon on the desktop and select the Properties entry In the opened Network window select the Services tab to display the currently installed services In the Services tab click Add select Microsoft TCP IP Printing Click OK type D i386 lt Enter gt where D is your CD ROM drive and click Continue In the Services tab click Add select the Remote Access Service entry and click OK If needed change the path displayed to D i386 where D is your CD ROM drive and click Continue The Remote Access Service files will be copied When the following message appears T
43. LIST OF REVISIONS ECO REV DATE DESCRIPTION PAGES APPR EO 00343 A Mar 2000 Draft for Beta Site All EO 00433 0 May 2000 First release All EO 00483 1 July 2000 Adapted for New Computer Dell Chapter 6 Addition of OptiPlex GX200 Appendix C Software Installation on Dell 610 EO 00534 2 Sep 2000 Introducing a shorter procedure for Chapter 6 Install from Cold Appendices B amp C Added Insite Check Procedure e Chapter 4 e Correction of Printer Configurations Section 3 11 e Addition of Localization Kit Numbers Table 2 3 3 Nov 2000 e Attaching the Activator to enable the 6 21 B 17 C 16 Y Ben Zeev eNTEGRA application and the applicable clinical licences Correcting the procedure for e 7 2 checking system configuration used after system upgrade e Changing size of C drive for4 GB B 3 Hard Disks of HP Kayak PCs e Installing the Network on HP Kayak B 5 EO 00677 4 Mar2001 e Correction of StarLink amp ApexNet e 3 18 R Pinko configuration Updated procedure for PostScript e 3 76 3 78 Printer installation and configuration EO 00746 5 June 2001 Correction of License Installation 6 21 R Pinko Updating the EOD configuration e 7 2 procedure e P N updated for eNTEGRA V1 5X Chapter 9 e InSite Installation Updated RAS instalation and new section 6 2 16 on page 6 21 Updated Section 3 11 InSite Eintitlement eNTEGRA P amp R Service
44. Load From Cold For Dell OptiPlex GX200 on page 6 2 includes instructions for installing the basic eNTEGRA software on the Dell OptiPlex GX200 computer All data currently on the system will be lost including the eNTEGRA database and all configuration parameters For installing the software on the HP Kayak refer to Appendix B For installing the software on the Dell 610 refer to Appendix C e Software Load from Warm on page 6 26 provides instructions for re installing the eNTEGRA application It preserves the installed database and all the configuration parameters It is mainly used for software upgrade purposes e Installing eNTEGRA Software Options and Licenses on page 6 27 provides instructions for installing various eNTEGRA options as well as licences for eNTEGRA applications eNTEGRA P amp R Service Manual 6 1 Rev 5 Direction 2263784 100 June 17 2001 Software Installation Software Load From Cold For Dell OptiPlex GX200 6 2 Software Load From Cold For Dell OptiPlex GX200 6 2 1 Overview A This chapter provides detailed instructions for installing the basic software of the eNTEGRA system on the Dell OptiPlex GX200 computer referred to as software load from cold Software load from cold is used when the hard disk is corrupted or replaced and the entire package must be installed from scratch CAUTION Load from cold is a destructive procedure and all the data on the disk will be lost
45. Modem Supplied locally for Europe 10 Isolation Transformer Spanish Localization Kit H3400ZB Spanish Keyboard Spanish Accessories CD Windows NT Spanish Spanish Manual Package Pre requisites CE Regulatory Kit Swedish Localization Kit H3400ZC Swedish Keyboard Swedish Accessories CD Window NT Swedish Swedish Manual Package Pre requisites CE Regulatory Kit Italian Localization Kit H3400ZD Italian Keyboard Italian Accessories CD Window NT Italian Italian Manual Package Pre requisites CE Regulatory Kit German Localization Kit H3400ZE German Keyboard German Accessories CD Window NT German German Manual Package Pre requisites CE Regulatory Kit Portuguese Localization H3400ZF Portuguese Keyboard Portuguese Accessories Kit CD Window NT Portuguese Portuguese Manual Package Pre requisites CE Regulatory Kit French Localization Kit H3400ZG French Keyboard French Accessories CD Window NT French French Manual Package Pre requisites CE Regulatory Kit Each Manual Package includes e Operator Manual Hardcopy e CIS Hardcopy e eNTEGRA On line Help CD eNTEGRA P amp R Service Manual Direction 2263784 100 2 4 Rev 5 June 17 2001 Introduction The eNTEGRA System Table 2 4 eNTEGRA Options Catalog Numbers Type Catalog Description Contents Accessories H2508LK SO
46. OS DO USU RIO NECESSITE DE UMA TRADU O ESTA DE RESPONSABILIDADE DO CLIENTE N O TENTE UTILIZAR O EQUIPAMENTO ANTES DE CONSULTAR E COMPREENDER O MANUAL DE SERVI O A N O OBSERV NCIA DESTE PODE ACARRETAR LES ES AO PROVEDOR DE SERVI OS OPERADOR OU PACIENTE CAUSADAS POR CHOQUE EL TRICO MEC NICO OU DE OUTRA NATUREZA IL PRESENTE MANUALE DI MANUTENZIONE DISPONIBILE SOLO IN LINGUA INGLESE SPETTA ALL UTENTE PROCURARSI UNA VERSIONE TRADOTTA NEL CASO IN CUI L ADDETTO ALLA MANUTENZIONE DOVESSE RICHIEDERLA NON TENTARE DI METTERE IN FUNZIONE L APPARECCHIATURA PRIMA DI AVER CONSULTATO IL MANUALE DI MANUTENZIONE ED AVERNE COMPRESO PIENAMENTE IL CONTENUTO LA MANCATA OSSERVANZA DI QUESTA AVVERTENZA PU PROVOCARE LESIONI AL PERSONALE DI MANUTENZIONE ALL OPERATORE O AL PAZIENTE DERIVANTI DA SCOSSE ELETTRICHE URTI O RISCHI DI ALTRA NATURA IESTE MANUAL DE SERVICIO S LO EXISTE EN INGL S SI ALG N PROVEEDOR DE SERVICIOS AJENO A GEMS SOLICITA UN IDIOMA QUE NO SEA EL INGL S ES RESPONSABILIDAD DEL CLIENTE OFRECER UN SERVICIO DE TRADUCCI N NO SE DEBER DAR SERVICIO T CNICO AL EQUIPO SIN HABER CONSULTADO Y COMPRENDIDO ESTE MANUAL DE SERVICIO LA NO OBSERVANCIA DEL PRESENTE AVISO PUEDE DAR LUGAR A QUE EL PROVEEDOR DE SERVICIOS EL OPERADOR O EL PACIENTE SUFRAN LESIONES PROVOCADAS POR CAUSAS EL CTRICAS MEC NICAS O DE OTRA NATURALEZA eNTEGRA P amp R Service Manual Rev 5 P N 2263784 100 vi June 17 2001
47. Prn3m 952 9 3 hmag 0 Prn3m 952 9 3 vmag 0 Prn3m 952 9 3 hmode 15 Prn3m 952 9 3 vmode iS Figure 3 7 HCdefaults win32 952 Lasercamera Section Part 3 eNTEGRA P amp R Service Manual Direction 2263784 100 3 43 Rev 5 June 17 2001 Installation Hardcopy Options format 12 Prn3m 952 12 desc 2 on 1 3 frames on each of 4 zones Prn3m 952 12 zones 4 zone 1 Prn3m 952 12 1 frames 3 Prn3m 952 12 1 width 024 Prn3m 952 12 1 height 024 Prn3m 952 12 1 contrasts D D D lt Edit to change Contrast 12x 1 Prn3m 952 12 1 lines 200 Prn3m 952 12 1 bdr lines 32 Prn3m 952 12 1 hmag 0 Prn3m 952 12 1 vmag 0 Prn3m 952 12 1 hmode 5 Prn3m 952 12 1 vmode 5 zone 2 Prn3m 952 12 2 frames 3 Prn3m 952 12 2 width 024 Prn3m 952 12 2 height 1024 Prn3m 952 12 2 contrasts D D D dit to change Contrast 12x 1 Prn3m 952 12 2 lines 200 Prn3m 952 12 2 bdr lines 32 Prn3m 952 12 2 hmag 0 Prn3m 952 12 2 vmag 0 Prn3m 952 12 2 hmode 5 Prn3m 952 12 2 vmode 5 zone 3 Prn3m 952 12 3 frames 3 Prn3m 952 12 3 width 024 Prn3m 952 12 3 height 024 Prn3m 952 12 3 contrasts D D D Edit to change Contrast 12x 1 Prn3m 952 12 3 lines 200 Prn3m 952 12 3 bdr lines 32 Prn3m 952 12 3 hmag 0 Prn3m 952 12 3 vmag 0 Prn3m 952 12 3 hmode 5 Prn3m 952 12 3 vmode 5 zone 4 Prn3m 952 12 4 frames 3
48. Rev 5 June 17 2001 System Description Software Description The Service Object Pair SOP Classes which the eNTEGRA P amp R s DICOM Application Entity AE supports for both the SCU and SCP role are listed in Table 5 9 Table 5 9 SOP Classes Supported for the SCU and SCP Role AE ROLE SCU SUPPORTED SOP CLASS Nuclear Storage SOP Class FUNCTIONALITY Images from the database can be sent to a system that supports the Nuclear Storage SOP Class in the SCP role SOP Class Secondary Capture Storage Images created by the screen save tool can be sent to a systems that supports the Secondary Capture Storage SOP Class in the SCP role Patient Study Root Query SOP Class Allows eNTEGRA to query the database of a remote systems that supports the Patient Study Root Query SOP Class in the SCP role Patient Study Root Fetch SOP Class Allows eNTEGRA to Fetch images from a remote systems that supports the Patient Study Root Fetch SOP Class in the SCP role The only images types eNTEGRA can fetch are ones that are defined by in it s SCP role These include Nuclear Ct MR and Secondary Capture eNTEGRA P amp R Service Manual Direction 2263784 100 5 16 Rev 5 June 17 2001 System Description Software Description Note Table 5 9 SOP Classes Supported for the SCU and SCP Role Continued AE ROLE SUPPORTED SOP CLASS FUNCTIONALITY
49. Starcam system must be upgraded to Starlink Version 4 See below for details For remote SP systems the eNTEGRA system s Ethernet Address and system name must be added to each system For remote DICOM systems the eNTEGRA system s hostname IP Address DICOM AE Title and DICOM port number must be configured The default DICOM AE title is the hostname in uppercase The DICOM port Note number for eNTEGRA is 104 eNTEGRA P amp R Service Manual 3 28 Rev 5 Direction 2263784 100 June 17 2001 Installation Remote LAN Configuration 3 9 2 Procedure Overview Table 3 12 Communication Configuration Steps Time Min Reference Configure all GENIE ACQ and 5 System e Acquisition System Service Manual Millennium VG Systems for Use the following parameters DICOM Communication to AE Title hostname in uppercase eNTEGRA P amp R Port No 104 Get eNTEGRA P amp R s Ethernet 5 minutes Section 3 9 3 Address Upgrade all Polestar and 15 system Section 3 9 4 Polestar i systems on network to eNTEGRA Ethernet LAN address Starlink V4 Upgrade all Build Standard 1 amp 2 30 system Section 3 9 5 system on network to Starlink V4 e eNTEGRA Ethernet LAN address Upgrade all Build Standard 0 15 system Section 3 9 6 systems on network to Starlink V3 Configure the SP based systems 5 system e Getting Ethernet Addresses and for communication with the names of SP based systems eNTEGRA system Section 3 9 7
50. TCP IP network protocol The Codonics Printer requires the following items to communicate with eNTEGRA ISG_1 license 10 character license key supplied by the vendor e snmpd software patch 3 5 floppy ipd software patch 3 5 floppy These items should be provided with the Codonics software If not contact Codonics Section 3 10 8 2 provides the basic procedure for interfacing configuring the Codonics Printer to eNTEGRA Section 3 10 8 3 provides details on interfacing the Codonics to the eNTEGRA Section 3 10 8 5 provides details on configuring the eNTEGRA and the Codonics for optimal image quality eNTEGRA P amp R Service Manual 3 71 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options 3 10 8 2 Basic Procedure This section provides the basic procedure to interface and configure the Codonics Printer with eNTEGRA 1 2 Obtain an IP Address for the Codonics Verify that the Codonics was configured correctly on the eNTEGRA via the Config utility Refer to Section 3 8 for details The Device Type should be set to ISGnp1600m The IP Address of the Codonics will also need to be entered Install Codonics printer per the Codonics Users Manual instructions and connect it to the Nuclear LAN Refer to Section 3 10 8 3 Configure the Codonics for communication with the eNTEGRA This includes assigning the Codonics s IP Address and Subnetmask to the printer Refer to the
51. Tiern Connan ata een N 3 21 3 8 4 8 Remote Access Confior eee eee ees 3 22 3 8 4 9 Modem Conti tirang seasan S S 3 23 3 8 4 10 Remote DataDass orscsssncnin a 3 25 3 8 4 11 Hardcopy Conio Aiesa 3 26 3 9 Remate LAN Conigura OM sicsssscsacisainicesasisneasiaidateiasaccarariiausalsiemasiaenniies 3 28 3 9 1 sli 8170s Oea 3 28 392 BN Von E ssi cintecs reserves O 3 29 A93 ENTEGRA Ethernet Address onnan 3 29 3 9 4 Starlink Version 4 Upgrade for Polestar and Polestar i Systems 3 30 3 9 5 Starlink Version 3 Upgrade for Starcam Build Standard 0 008 3 31 3 9 6 Starlink Version 4 Upgrade for Starcam Build Standard 1 amp 2 0 3 31 3 9 7 Getting the Ethernet Address and names of SP Based Systems 3 32 3 10 Hadeco ODIDI srana eee 3 33 3 10 1 PoE A E EE Seine cle eae ie eieeeenececan 3 33 3 10 2 Imation 3M Lasercameras Configuration cc cccesecessseceeeeeeeeseeeeees 3 34 2121 Oe ania ee ee 3 34 3 10 2 2 Pasie Pocs enaa A i 3 35 3 10 23 Finding the SCSI Device Number of the DASM LCAM 3 36 3 10 2 4 Ee a SI rice eee eee 3 37 3 10 2 5 Image Tei a saeco cee acon eee es 3 40 eNTEGRA P amp R Service Manual ii Rev 5 Direction 2263784 100 June 17 2001 Table Of Contents 3 10 3 Kodak Laser Camieras Configuration seit cnc 3 47 3 10 3 1 CTE O ana aaeeeoaisaemeaenes 3 47 3 10 3 2 Darie Poc UNT enS 3 48 3 10 3 3 ares 0 ee E 3 49 3 10 3 4 Image Quality Configuration sssini e 3 53
52. Upgrading From GENIE P amp R Archive the Aladdin Protocols study to the optical cartridge as follows i Select the Aladdin Protocols study ii Click the Archive tab iii In the Archive panel click the Job Options button iv In the opened Archive Retrieve dialog a Click Archive Current Dataset Selection b Click OK v Click the Archive button on the Archive panel vi In the opened warning click Yes 4 Perform Low Level Format as per Section A 3 below 5 Install the eNTEGRA software from scratch starting from Software Load From Cold For Dell OptiPlex GX200 on page 6 2 or Appendix B Software Installation on HP Kayak or Appendix C Software Installation on Dell Precision 610 which ever applies to your PC 6 Configure the eNTEGRA starting from Site Configuration on page 3 14 7 After eNTEGRA installation and configuration have been completed import GENIE Review Templates stored on the optical cartridge into eNTEGRA as follows a mo ao s Verify that the optical cartridge to which you archived the Review Templates and or User Protocols is inserted in the optical drive Click the Archive tab Click the Device tab corresponding to the Optical Drive Click the Attach button Click the Directory button Select the patient CORRECTIONS DIRECTORY from the archived patients list For each system to which the Review Templates are to be restored i Select the relev
53. already has NT installed a message is displayed a Press lt N gt New to reinstall NT b Press lt Enter gt c Press lt D gt Delete to delete the current partition d Press lt Enter gt e Press lt L gt Delete f Ifthere is an additional partition press the lt gt key to highlight it and repeat the procedure to delete this partition press D then press lt Enter gt and press L 12 Upon the message Create the following partitions in the whole disk unpartitioned space If any partitions exist delete them as follows a Select the partition and press lt D gt lt Enter gt lt L gt b If there is an additional partition press the lt gt key to highlight it and repeat the procedure to delete this partition press D then press lt Enter gt and press L Otherwise a Press lt C gt to create a new partition b Delete the number displayed by pressing lt Backspace gt c Type 3000 and press lt Enter gt d While the 1st partition is highlighted press lt Enter gt to install Win dows NT on drive C eNTEGRA P amp R Service Manual 6 5 Rev 5 Direction 2263784 100 June 17 2001 Software Installation Software Load From Cold For Dell OptiPlex GX200 13 Install Windows NT as follows a Inthe opened dialog use the lt gt key to highlight the line Format using NTFS and press lt Enter gt Drive C will be formatted It may take several minutes b When prompted press lt Enter
54. change the path displayed to D i386 where D is your CD ROM drive and click Continue The Remote Access Service files will be copied When the following message appears There are no RAG click Yes to invoke Modem Installer In the opened Install New Modem dialog check the Don t detect my modem and click Next For systems with a modem installed select the modem manufacturer and model from the scrollable list and click Have Disk For systems with no modem installed select Standard type click Next select COM2 and click Next OK Continue If required insert the manufacturer s installation diskette into the floppy drive browse to the appropriate directory using the Browse button then click OK The modem drivers are copied to the hard disk Click the Properties button and enter the modem properties Remove the Windows NT CD from the drive Close the Network Properties window and click Yes to restart the system Proceed to Installing the FTP Service on page B 15 eNTEGRA P amp R Service Manual 14 Rev 5 Direction 2263784 100 June 17 2001 Installing the FTP Service B 12 Installing the FTP Service Insert the Windows NT CD into the CD drive Right click the Network Neighborhood icon on the desktop and select Properties to display the Network dialog Click the Service tab and click the Add button From the opened Select Network Service list select Microsoft
55. click Proceed When the VLA HLA and SA obliques are created for the eight gates click on the Process Tab When the VLA HLA and SA obliques are created for the eight gates click on the Review Tab Click on the Review Obliques on the Review tab The three planes Rest Stress obliques are displayed and the Beating Slices screen is created in the background A progress slider displayed on the control area advanced as the generation of the Beating Slices screen progresses When the Beating Slices screen has been generated the progress slider is replaced by a Beating on Click check box Drop down the File menu and select the Quit entry to quit the protocol eNTEGRA P amp R Service Manual 4 4 Rev 5 Direction 2263784 100 June 17 2001 Functional Checks Review Template Test 4 3 Review Template Test 1 Select a study 2 Click on the Load icon below the Patient Selector page The screen switches to the Processing amp Review screen 3 On the green Processing card drop down the View menu and select the Screen Format entry 4 Click the black square icon in the Screen Format and on the 1X1 button in the Multiple Image Format Verify that a single image now fills the screen 5 Click LINEAR on the Color Maps tool 6 Drop down the File menu and select the Save Review Template entry 7 Type in Test for Template name and click OK 8 Drop down the File menu and select the Exit Card entry 9 Click on
56. click on My Computer icon located on the desktop 3 Double click the D drive CD ROM Drive P oN Dw For the English version skip to Step 5 below For other languages double click the applicable language Double click the IE5 directory Double click install bat When installation has been completed the system will reboot Proceed to Installing RAS Modem and TCP IP for Printing on page B 14 eNTEGRA P amp R Service Manual 13 Rev 5 Direction 2263784 100 June 17 2001 Installing RAS Modem and TCP IP for Printing B 11 Installing RAS Modem and TCP IP for Printing Installation of the Remote Access Service RAS is required for DICOM Part 10 1 When the system comes up press lt Alt gt lt Ctrl gt lt Del gt and login into the system with Username entegra Password entegra 2 Click OK 3 Insert the Windows NT Workstation CD ROM and close the opened 10 11 12 13 14 15 16 17 18 Windows CD window Click right on the Network Neighborhood icon on the desktop and select the Properties entry In the opened Network window select the Services tab to display the currently installed services In the Services tab click Add select Microsoft TCP IP Printing Click OK type D i386 lt Enter gt where D is your CD ROM drive and click Continue In the Services tab click Add select the Remote Access Service entry and click OK If needed
57. configuration parameters that need to be set on the SID for the DASM LCAM interface The Sterling Service Engineer will be responsible for configuring and interfacing the SID Table 3 21 DASM LCAM to DuPont Lasercamera Interface Configuration Interface Parameter Setting Host Communications Baud Rate 1200 Stop Bits 1 Data Bits 8 Parity Even Parity Enable Enable Character Pacing 0 End Of Message CR Protocol ACK NACK Host Protocol Type 952 Image Image Size 1024x1024 Pixel Width 8 Parity Even Parity Enable Enable 3 10 4 4 Image Quality Configuration The 952 protocol image quality parameters defined in HCdefaults win32 file are ignored by the DuPont SID All image quality adjustment should be performed by the Sterling Service Engineer eNTEGRA P amp R Service Manual 3 57 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options 3 10 5 Fuji Laser Cameras Configuration 3 10 5 1 Overview This section provides details on how to connect the Fuji Lasercameras to the eNTEGRA system and how to configure both the eNTEGRA and Lasercamera to produce good quality films The eNTEGRA hardcopy server sends commands and high resolution digital image data to the DASM LCAM or DASM VDB over the SCSI 2 bus using the Analogic DASM SCSI command set The DASM LCAM converts these commands into the 952 commands and a digital image Note Due to image quality
58. contain this OSI network software A separate OSI software package must be loaded in addition to Windows NT Installing the OSI shareware package requires the following steps 1 Installing the IMPART ISO 8073 Network Driver Section 6 4 2 2 2 Installing the Boldon James ADI program Chapter 6 4 2 3 3 Installing patch for ADI Chapter 6 4 2 4 4 Configuring the Remote OSI Stations on the eNTEGRA system refer to Section 3 8 4 5 5 Configuring the Starlink and OSI accessed systems on the local eNTEGRA system Section 3 8 4 5 6 Configuring the eNTEGRA on the Remote Starlink SP systems Section 6 4 2 5 eNTEGRA P amp R Service Manual 6 29 Rev 5 Direction 2263784 100 June 17 2001 Software Installation Installing eNTEGRA Software Options and Licenses 6 4 2 2 Installing the IMPART ISO 8073 Network Driver The following instructions relate to installation from the CD ROM where the files are in the directory OSIMISoTSpNT 1 Log into your system as before with the username entegra 2 Close down the eNTEGRA application and double click the Stop Servers icon to shutdown all servers 3 Click on the Start icon on the Tasks Bar and select Settings gt Control Panel 4 Double click the Network icon 5 Goto the Protocols tab and click Add 6 Click the Have Disk button 7 In the Insert Disk window type in the path for the installation files on the CD ROM E OSINsoTspNt where E is
59. contrasts D_ lt Edi Se aroi Edit to chane Contrast 1x1 Prn3m 952 1 1 bdr lines 32 Prn3m 952 1 1 hmag 0 Prn3m 952 1 1 vmag 0 Prn3m 952 1 1 hmode 15 Prn3m 952 1 1 vmode 15 format 2 Prn3m 952 2 desc 2 on 1 2 frames on 1 zone Prn3m 952 2 zones 1 Prn3m 952 2 1 frames 2 Prn3m 952 2 1 width 1024 Prn3m 952 2 1 height 1024 Prn3m 952 2 1 contrasts D D e Edit to change Contrast 2x1 Prn3m 952 2 1 lines 4800 Prn3m 952 2 1 bdr lines 32 Prn3m 952 2 1 hmag 0 Prn3m 952 2 1 vmag 0 Prn3m 952 2 1 hmode 15 Prn3m 952 2 1 vmode 15 Figure 3 5 HCdefaults win32 952 Lasercamera Section Part 1 eNTEGRA P amp R Service Manual Direction 2263784 100 3 41 Rev 5 June 17 2001 Installation Hardcopy Options format 3 Prn3m 952 3 desc 2 on 1 2 frames in 2 zones Prn3m 952 3 zones 2 zone 1 Prn3m 952 3 1 frames 1 Prn3m 952 3 1 width 1024 Prn3m 952 3 1 height 1024 Prn3m 952 3 1 contrasts D lt Edit to change contrast 2x1 Prn3m 952 3 1 lines 2400 Prn3m 952 3 1 bdr lines 32 Prn3m 952 3 1 hmag 0 Prn3m 952 3 1 vmag 0 Prn3m 952 3 1 hmode 15 Prn3m 952 3 1 vmode 15 zone 2 Prn3m 952 3 2 frames 1 Prn3m 952 3 2 width 1024 Prn3m 952 3 2 height 1024 Prn3m 952 3 2 contrasts D Edit to change Contrast 2x1 Prn3m 952 3 2 lines 2400 Prn3m 952 3 2 bdr lines 32 Prn3m 952 3 2 hmag 0 Prn3m 952 3 2 vmag 0 Prn3m 952 3 2 hmode 15 Prn3m 952 3
60. eNTEGRA Section 3 10 10 3 provides details on the physical interface between the DICOM printers and the eNTEGRA Section 3 10 10 4 provides details on configuring the eNTEGRA and the DICOM printer eNTEGRA P amp R Service Manual 3 81 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options 3 10 10 2 Basic Procedure This section provides the basic procedure to interface and configure DICOM Printers with eNTEGRA 1 If necessary connect the printer to the Nuclear LAN Refer to Section 3 10 10 3 Obtain the following information for the DICOM printer a AE Title HOSTNAME in upper case b TCP IP Port 104 c IP Address Verify that the printer was configured correctly on the eNTEGRA via the eNTEGRA Configuration window Section 3 8 4 11 as follows a The selected Type in the Add Edit Printer Device window is Dicom b The correct Sub Type was selected in the Dicom Printer Setup window either of Imation 8300 Imation 8700 Agfa 2000 color Agfa 2000 B amp W or Codonics Log into eNTEGRA select the Formatter Static image from the Default Patient Calibration study and click the Load icon located on the Patient Selector Control Bar Click the Camera tool in the Display Screen Click the Down Arrow in the Film dialog select the Dicom printer and click Submit If a No image is printed refer to Section 8 2 6 for details on troubleshoot ing b An image is printed a
61. from cold procedure consists of the following steps to be performed in the given order 1 Installing the Windows NT Operating System on page C 3 including disk partitioning and formatting Drive C 2 Installing Windows NT Networking on page C 5 3 Installing Service Pack 6a on page C 8 4 Installing the Display Driver on page C 8 5 Adjusting the Display Properties on page C 9 6 Installing the Sound Driver on page C 10 7 Setting System Options on page C 10 8 Installing Internet Explorer 5 on page C 12 9 Installing RAS Modem and TCP IP for Printing on page C 13 10 Installing the FTP Service on page C 14 11 Formatting Drive D as NTFS on page C 15 12 Installing the eNTEGRA Application and Its Accessory Components on page C 16 13 Configuring the system as per Section 3 8 on page 3 14 14 Configuring the Network as per Section 3 9 on page 3 28 15 Configuring the Hardcopy Devices as per Section 3 10 on page 3 33 16 Performing the Functional Checks detailed in Section Chapter 4 eNTEGRA P amp R Service Manual 2 Rev 5 Direction 2263784 100 June 17 2001 Installing the Windows NT Operating System C 2 Installing the Windows NT Operating System 1 Turn ON the system and immediately insert the NT Installation CD 2 When the words Windows NT Setup appear at the top of the screen press lt F6 gt repeatedly until the full Windows NT Setup screen appears and the white line at the bottom of the scree
62. from the Not member of list to the Member of list g Click OK h Inthe New User window enter Username entegra Password entegra Confirm Password entegra i Click OK again j Close the User Manager window mono 44 Click the Start button on the Task Bar at the bottom of the screen and select Shutdown the system 45 In the Shut Down window select Close all programs and log as a different user then click Yes 46 When prompted press lt Alt gt lt Ctrl gt lt Del gt and login into the system with Username entegra Password entegra 47 Click OK 48 Close the Welcome window 49 Proceed to Installing Service Pack 6a on page C 8 eNTEGRA P amp R Service Manual 7 Rev 5 Direction 2263784 100 June 17 2001 Installing Service Pack 6a C 4 Installing Service Pack 6a This installation depends on the language being used 1 For English version Insert the eNTEGRA Application CD into the CD Drive and double click the My Computer icon located on the desktop For other languages Insert the eNTEGRA Accessories Software CD into the CD Drive and double click the My Computer icon located on the desktop 2 Double click the D drive CD ROM Drive 3 Double click the SP6 directory P For the English version skip to step 5 below For other languages double click the applicable language directory 5 Double click SP6ai386 exe 6 Check the Accept License Agreement box if re
63. gt twice to start copying the NT files c Upon system prompt remove the Windows NT CD and the floppy d When prompted press lt Enter gt to reboot 14 After reboot the installation continues followed by another automatic reboot 15 When prompted insert the NT installation CD into the CD drive and click OK 16 Proceed to Installing Windows NT Networking on page 6 7 eNTEGRA P amp R Service Manual 6 6 Rev 5 Direction 2263784 100 June 17 2001 Software Installation Software Load From Cold For Dell OptiPlex GX200 6 2 5 Installing Windows NT Networking Note 1 In the Windows NT Setup window click Next to continue 2 Inthe opened Setup Options window select Typical and click Next 3 In the opened Name and Organization window type in your site_name and organization_name and click Next 4 Inthe Registration window type in your product_ID recorded on the provided manual and click Next 5 When prompted type in your computer name as defined in the pre installation checklist and click Next 6 When prompted type in your password as defined in the pre installation checklist the following description will use the password elgems 7 Retype the password and click Next 8 When prompted select no do not create an emergency repair disk and click Next 9 In the opened Windows NT Components dialog select Install the most common components and click Next 10 Upon
64. ieee A 1 A 2 Upgrading From GENIE P amp R sccictensericensnienccindnnnibnnieane A 2 A 3 LU so a Nea i A oe ear pees Er E rTP REDE outer errr E ERT A 5 eNTEGRA P amp R Service Manual vi Rev 5 Direction 2263784 100 June 17 2001 Table Of Contents Appendix B Software Installation on HP Kayak cccsssssssscsssssssseeeees B 1 B 1 DVE ON nE S eater enccacareeccnneiceant B 1 B 1 1 Time PoTN eee ee B 1 B 1 2 Process Overview wee B 2 B 2 Installing the Windows NT Operating System ceeeeesecseceseeeeeeeeneeees B 3 B 3 Installing Windows NT Networking scscccaiicacssarinvecsatoanamenieanmnmnnne B 4 B 4 Tia oer eE PiE Gien csi eee B 7 B 5 Installing the Display Driver amp Adjusting the Display eeceeeseeeeeteees B 8 B 6 Tostaling tbe Sound Driver osiris a E B 9 Ls Installing the HP Multimedia Keyboard Utility oc ccctexcctscescccctsvescassaetenscesveceede B 9 B 8 Installing Service Pack Oe cicccccccccescccnencsaensdivniendiseeiemeceaieieiees B 10 B 9 Senne OO ois recta B 10 B 9 1 sehin the Dats Formal ieee B 11 B 9 2 Setting the Application Event Viewer Loggings eseesssesseseereeeerseee B 11 B 9 3 seina the Task Bar Properes sensorerna rearencnamamnemens B 11 B 9 4 Setting the Virtual Memory ascii isrener B 12 BSS senne he VER Us eae ean eee B 12 B 10 Installing Internet Explorer S ccccannninndinsnnnaiuminen B 13 B 11 Installing RAS Modem and TCP IP for Printing eee eeeeeeeeseeeeeeeeee
65. image quality adjustment should be performed by the Konica Service Engineer eNTEGRA P amp R Service Manual Direction 2263784 100 June 17 2001 Installation Hardcopy Options 3 10 7 Polaroid Helios Lasercamera Installation Configuration 3 10 7 1 Overview Note This section provides details on how to connect the Polaroid Sterling Helios Lasercameras to the eNTEGRA system and how to configure both the eNTEGRA and Lasercamera to produce good quality films The eNTEGRA hardcopy server sends commands and high resolution digital image data to the Helios via the Nuclear Local Area Network LAN using the Ip command over the TCP IP network protocol The Helios Lasercamera requires at a minimum the Primary Ethernet Module In addition if more the one device will print to the Helios via the network interface the Multiple Ethernet Image Manager software will need to be activated Contact your Helios representative for details Section 3 10 7 2 provides the basic procedure for interfacing configuring the Helios Lasercameras to eNTEGRA Section 3 10 7 3 provides details on interfacing the Helios Lasercameras to the eNTEGRA Section 3 10 7 4 provides details on configuring the eNTEGRA and the Lasercamera for optimal image quality eNTEGRA P amp R Service Manual 3 66 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options 3 10 7 2 Basic Procedure This section provides the basic pr
66. menu and select the Screen Format entry Select a format for displaying 2 whole bodies with 3 static images On the Color Maps panel click the button In the opened window select the INVERSE entry to replace map No 5 and click OK Apply a different color map to each image On the Color Maps panel turn OFF the Color Bar Click the down arrow on the Color Maps panel and select the All entry Click the button on the Color Maps panel select the Hot Iron entry and click OK Select an image and apply the Hot Iron map Click the down arrow on the Color Maps panel and select the Current entry Apply the Default map GE Colors to each image 15 Drop down the File menu and select the Exit Card entry eNTEGRA P amp R Service Manual 4 2 Rev 5 Direction 2263784 100 June 17 2001 Functional Checks Processing Validation 4 2 Processing Validation 4 2 1 Checking the Availability of Licensed Options 1 For each licensed option recorded in the pre installation check list except ECToolbox select an appropriate dataset s from the patient database then verify that the relevant protocol icon is available in the Processing tab For the ECToolbox application select rest and stress datasets one of which must be gated click on the ECToolbox icon within the Cardiac Category then click the Start ECToolbox button 3 Click the Both Rest and Stress Data button on the Recon tab 10 11 12
67. must be tested for continuity before use and then connected to the main grounding point of the equipment being installed 3 Floors with epoxy glue generate static discharges Advise hospital and use special spray to avoid discharge eNTEGRA P amp R Service Manual 1 3 Rev 5 Direction 2263784 100 June 17 2001 Safety Guidelines and Regulatory Installation Safety Measures 1 4 Installation Safety Measures 1 Read the installation instructions prior to installation 2 Make sure that the installation area is clean prior to installation 3 Whenever handling electrostatic devices or circuit boards use a grounding strap and wrist band This grounding strap and wrist band must be tested for continuity before use and then connected to the main grounding point of the equipment being installed 4 Throughout the entire installation you must be careful to correctly replace and service all fuse and cable guards Similarly you must correctly fit all cable covers before installation is completed 1 5 Safety Definitions Warnings and Cautions are used throughout this manual The identified hazards are classified as follows WARNING Warnings are used to identify conditions or actions for which a specific hazard is known to exist which may cause severe personal injury death or substantial property damage if the instructions are ignored CAUTION A Cautions are used to identify conditions or actions for which a potential
68. on page 8 8 eNTEGRA P amp R Service Manual Direction 2263784 100 8 2 Rev 5 June 17 2001 Troubleshooting and Repair Troubleshooting 8 2 1 Operating System Installation Problems Note Refer to Microsoft Windows NT Workstation booklet provided with the system 8 2 2 eNTEGRA Installation Problems Symptom Possible Cause Corrective Action During system start up A new archive device 1 Disconnect the EOD the EOD is assigned was added to the system 2 Click Start in the task bar and select drive D instead of Programs gt Administrative Tools gt drive E Disk Administrator 3 Assign F as the CD ROM drive as follows a Click right on the CD ROM Drive and select Assign Drive Letter b Click the down arrow next to the Assign Drive Letter radio button select F and click OK 4 Assign the Archive to drive E as described above then re assign it to drive D 5 Reconnect the EOD to the SCSI Narrow slot After first time installation Missing or wrong system Open the file einstein error log located of eNTEGRA the license in D Einstein Einstein_Project exe application doesn t start using Notepad and the following error 2 Scroll to the end of the file and check for message is displayed the message No node locking license 4 Meaning that the basic eNTEGRA license is incorrect or missing Error while initializing eNTEGRA check servers 1 I
69. on the eNTEGRA system then edit the specific parameters and powerdown the eNTEGRA application Refer to Section 3 10 2 5 b Adjustments will be made via the Lasercamera s input module then verify that the HCdefaults win32 file on the eNTEGRA has the Density and Contrast parameter set to D before editing the input mod ule s parameters Refer to Section 3 10 2 5 After the HCdefaults win32 file is edited the eNTEGRA must be completely Note restored including servers in order for the changes to take effect 8 Repeat steps 5 through 7 until optimal film quality is achieved eNTEGRA P amp R Service Manual 3 35 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options 3 10 2 3 Finding the SCSI Device Number of the DASM LCAM Click Start on the Task Bar and select Run to open the Run Window Inthe Open input filed type regedit and click OK Inthe Registry Editor window select the following directory HKEY_LOCAL_MACHINE HARDWARE DEVICEMAP Scsi Scan the Identifier in each Scsi Port X directory where X is the Port Number as follows a Select the directory Scsi Bus O target Id Y Logical Unit Id 0 where Yis the Target ID Number b Check whether the Identifier is ANALOG LCAM 3M The Scsi Port with Indentifier ANALOG LCAM 3M is the Port Number of the DASM LCAM to be selected as the Physical Drive in the 3M Printer Setup window See Section 3 8 4 11 eNTEGRA P amp R Servic
70. opened to the Settings tab Click the down arrow under the Color Palette and select True Color Move the slider in the Desktop Area to display a resolution of 1280 by 1024 pixels Click the down arrow under Font Size and select Small Fonts 8 Click the down arrow under Refresh frequency and select 85 Hertz 10 11 12 13 Click the Test button Click OK to display the test screen In the testing Mode window click Yes if you have seen the bitmap properly In the Display Properties window click the OK button Proceed to Installing the Sound Driver on page 6 13 eNTEGRA P amp R Service Manual 6 12 Rev 5 Direction 2263784 100 June 17 2001 Software Installation Software Load From Cold For Dell OptiPlex GX200 6 2 9 Installing the Sound Driver D P O e E If necessary insert the eNTEGRA CD ROM to the CD ROM drive Double click the My Computer icon on the Desktop Double click Control Panel Double click Multimedia and click the Devices tab Click Add select Unlisted or Updated Driver and click OK Type in the path C Drivers Audio for the driver installation files and click OK A dialogue box Add Unlisted or Updated Drivers appears Click OK 8 Ifthe Driver Exists window appears click on the New button Click OK in the About Soundmax Integrated Digital Audio Window 10 Click OK to close the Multimedia Properties window 11 Proceed to Setting Sy
71. select Shutdown the system In the Shut Down window click Close all programs and log as a different user then click Yes When prompted press lt Alt gt lt Ctrl gt lt Del gt and login into the system with Username entegra Password entegra Proceed to Installing Service Pack 6a on page B 7 eNTEGRA P amp R Service Manual 6 Rev 5 Direction 2263784 100 June 17 2001 Installing Service Pack 6a B 4 Installing Service Pack 6a This installation depends on the language being used 1 For English version Insert the eNTEGRA Application CD into the CD Drive and double click the My Computer icon located on the desktop For other languages Insert the eNTEGRA Accessories Software CD into the CD Drive and double click the My Computer icon located on the desktop 2 Double click the D drive CD ROM Drive 3 Double click the SP6 directory 4 For the English version skip to step 5 below For other languages double click the applicable language directory 5 Double click SP6ai386 exe 6 Check the Accept License Agreement box if requested 7 Uncheck Backup files necessary to uninstall service pack 8 Click Install 9 When prompted click on Restart to reboot the system and logon as before 10 o to Installing the Display Driver amp Adjusting the Display on page B 8 eNTEGRA P amp R Service Manual 7 Rev 5 Direction 2263784 100 June 17 2001 Installing the
72. the CD ROM drive Click OK 8 When the product name IMPART ISO 8073 Transport is displayed in the Select OEM Option window click OK 9 The licences agreement will be displayed Click Yes to confirm 10 A dialog box will be displayed requesting the directory in which to install the Transport files Click OK to confirm the default directory 11 In the next dialog click Yes to confirm the creation of the specified directory 12 In the Bolden James Installation window click OK 13 Wait for the installation to complete Upon the message IMPART ISO 8073 Transport installed successfully click OK 14 In the open Network window click Close 15 After the network settings have been updated you will need to reboot for the changes to become affective eNTEGRA P amp R Service Manual 6 30 Rev 5 Direction 2263784 100 June 17 2001 Software Installation Installing eNTEGRA Software Options and Licenses 6 4 2 3 Installing the Boldon James ADI Program 1 Googe gt Close down the eNTEGRA application and double click the Stop Servers icon to shutdown all servers Double click My Computer icon on the Desktop Double click the CD drive letter E Navigate to E OSI impart5 disk1 Run the Setup exe installation program located in Click Yes in the Licence Agreement dialog In the License File Location window click Continue to use the default license 7 Click Continue to use the default path
73. the Kodak ser vice engineer will need to edit the parameters on the input module Refer to Section 3 10 3 4 Repeat steps 6 through 8 until optimal film quality is achieved eNTEGRA P amp R Service Manual 3 48 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options 3 10 3 3 Lasercamera Connection This section provides details on how to interface the Kodak Lasercameras to the eNTEGRA system via the DASM LCAM a Interface Wiring Figure 3 11 and Table 3 17 detail the interface between the eNTEGRA and the Kodak Lasercameras using the DASM LCAM Input Module i Kodak Lasercamera DASM LCAM Figure 3 11 eNTEGRA to Kodak Lasercamera Interconnection via the DASM LCAM Table 3 17 DASM LCAM to Kodak Lasercamera Cable Summary arg Description Part Source Length Reference 1 Peripheral Tower SCSI Cable 46 325201P5 im Section 5 1 3 2 37 Pin LCAM Image Data Cable RS485 Kodak 45m Kodak Service Engineer 3 MOD42 Cable 25 to 15 pin converter Kodak lt im 4 15 Pin Host Communication Cable RS422 Kodak 45m Note Refer to Section 5 1 3 1 for pinout details on the DASM LCAM eNTEGRA P amp R Service Manual 3 49 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options b Interface Configuration The Kodak Lasercamera s input module must be configured to communicate with the eNTEGRA Table 3 18 summarizes the configuratio
74. the Review Template tab in the bottom right part of the screen 10 Verify that Test appears in the opened Review panel and is highlighted in blue 11 Click Start Review Template and verify that the display is restored as saved above a single image fills the screen with linear color table 12 Drop down the File menu and select the Exit Card entry The screen returns to the Patient Selector 13 Click the Delete Template button in the bottom right corner of the Review panel eNTEGRA P amp R Service Manual 4 5 Rev 5 Direction 2263784 100 June 17 2001 Functional Checks Checking the Default Hardcopy Device 4 4 Checking the Default Hardcopy Device l 2 3 Select a WB Bone study Click on the Load icon below the Patient Selector page Click the Printer icon the 2nd left most icon in the upper left corner of the screen Click the Submit button 5 Check the printout and verify that the processing screen was printed correctly 4 5 Accessing the Optical Drive Archive 4 Click the Archive tab Click the Directory button on the EOD tab Sony or Pioneer whichever apples The list of the optical drive studies is displayed Select a study from the local Patient Selector page and click on the Archive button on the EOD tab Verify that the selected study was copied from the local archive to the EOD archive eNTEGRA P amp R Service Manual 4 6 Rev 5 Direction 2263784 100 June 17 20
75. the eNTEGRA Application and Its Accessory Components on page B 17 Configuring the system as per Section 3 8 on page 3 14 Configuring the Network as per Section 3 9 on page 3 28 Configuring the Hardcopy Devices as per Section 3 10 on page 3 33 Performing the Functional Checks detailed in Section Chapter 4 eNTEGRA P amp R Service Manual 2 Rev 5 Direction 2263784 100 June 17 2001 Installing the Windows NT Operating System B 2 Installing the Windows NT Operating System Turn ON the system and immediately insert the NT Installation CD When the HP Kayak opening screen appears press lt F8 gt for Boot Order 3 From the opened Boot Menu select ATAPI CD ROM Drive and press lt Enter gt The setup program is loaded When prompted press lt Enter gt to continue 5 When prompted press lt Enter gt to continue 6 In the opened licence Agreement page scroll down to the bottom using the lt PgDw gt key and press lt F8 gt If the displayed list matches your computer press lt Enter gt 8 Upon the message Create the following partitions in the whole 10 11 12 disk unpartitioned space a Press lt C gt delete the number displayed b If Hard Disk size is gt 9GB type 3000 for drive C and press lt Enter gt Otherwise for 4 GB Hard Disks type 1700 for drive C and press lt Enter gt c Press the lt gt key Press lt C gt and accept the defaults by pressing lt En
76. the message Installing Windows NT networking click Next 11 Check Do not connect this computer to a network at this time and click Next 12 Click Finish to finish setup 13 In the opened Date Time Properties window a Set the appropriate date and time in the Date amp Time page b Click the Time Zone tab click on the down arrow to display the Time Zone list select the appropriate Time Zone and click OK c Click Close 14 If the system finds the video adapter click OK then click Cancel for Video card driver installation which will be installed later As long as the display driver is not installed an Invalid Display Settings error message will be displayed after each reboot Click OK and ignore the message 15 When asked to restart the computer remove the Windows NT CD and press the Restart button 16 When prompted press lt Alt gt lt Ctrl gt lt Del gt and login into the system with User Name Administrator Password elgems 17 Click lt OK gt 18 In the Welcome screen that is opened click Close 19 Insert the eNTEGRA Application CD into the CD ROM drive eNTEGRA P amp R Service Manual 6 7 Rev 5 Direction 2263784 100 June 17 2001 Software Installation Software Load From Cold For Dell OptiPlex GX200 20 21 22 23 24 25 26 2T 28 29 30 31 32 33 34 35 36 37 38 39 40 Double click My computer D
77. to the eNTEGRA Config utility refer to Section 3 6 and Section 3 8 for details The Device Type should be set to SG3m in the Printers tab in the Config utility 2 Install and connect the host and image data runs between the Fuji Multiformatter and the DASM LCAM This should be done by the Fuji Service Engineer Refer to Section 3 10 5 3 3 Configure the Fuji Multiformatter for communication with the DASM LCAM This should be done by the Fuji Service Engineer Refer to Section 3 10 5 3 4 Power up the systems in the following order to assure proper synchronization Lasercamera Multiformatter DASM LCAM and then the eNTEGRA 5 Log into eCNTEGRA select the Formatter Static image from the Default Patient Calibration study and click the New icon located on the Patient Selector Control Bar Click the Camera tool in the Display Screen Click the Down Arrow in the Film dialog select the Fuji Lasercamera and click Submit 6 If a No image is printed refer to Section 8 2 5 for details on troubleshoot ing b An image is printed analyze the image and determine if additional adjustments are required 7 Any adjustments for image quality will be made on the Multiformatter by the Fuji Service Engineer Refer to Section 3 10 5 5 8 Repeat steps 5 through 7 until optimal film quality is achieved eNTEGRA P amp R Service Manual 3 59 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options 3 10 5 3 Laser
78. v Commissioning System Section 3 13 v Completion Section 3 14 Figure 3 1 Installation Flow Chart eNTEGRA P amp R Service Manual Direction 2263784 100 3 4 Rev 5 June 17 2001 Installation Unpacking 3 2 Unpacking 3 2 1 Packing List Use Table 3 3 to verify that you have received all items Table 3 3 Packing List Contents Documents General Documents Software Licenses and Activator eNTEGRA Operator Manual eNTEGRA Service Manual Release Notes CIS Monitor Monitor Video Cable Power Cable Color Monitor Users Guide Processor Unit Personal Computer Accessories Kit Keyboard Mouse Power Cables PC User s Manual Local Kit country dependent Isolation Transformer Power Cables OEM Documentation Modem for USA only OEM Documentation Keyboard European Options only Operator s Guide in relevant language and Installation Instructions DASM LCAM Option DASM LCAM Users Guide WARNING Do not discard any packing material until installation is complete eNTEGRA P amp R Service Manual Direction 2263784 100 3 5 Rev 5 June 17 2001 Installation Unpacking 3 2 2 Damage in Transit At the time of delivery examine all packages for external damage If damage to any package is apparent notify your installation specialist before continuing 3 2 3 Product Locator Cards Rem
79. 0 5 Konica Lasercamera DASM LCAM 3M Section 3 10 6 Codonics Color Printer Network np1600m Section 3 10 8 Helios Lasercamera Network helios Section 3 10 7 PostScript compatible Network postscript Section 3 10 9 printer Printer Port DICOM Printers Network DCMI8300 Section 3 10 10 DCMI8700 DCMA2KCL DCMA2kKBW DCMcod The only DICOM printers that have been validated are the Imation 8300 DCM8300 Imation 8700 DCMI8700 AGFA Drystar DCMA2KCL and DCMA2KBW and the Codonics 1660 DCMcod A maximum of 4 devices can be configured on the hardcopy server eNTEGRA P amp R Service Manual Direction 2263784 100 3 27 Rev 5 June 17 2001 Installation Remote LAN Configuration 3 9 Remote LAN Configuration 3 9 1 Introduction The eNTEGRA system utilizes two network protocols for communication to remote systems m e OSI network protocol used by Starlink protocol which is used for communication with Starcam systems M Link systems and Starlink agent systems SP based systems residing on the ApexNet LAN e TCP IP network protocol used for DICOM communication with other eNTEGRA P amp R systems GENIE ACQ systems Millennium VG systems and other remote DICOM systems Remote Database and Remote Connectivity For remote Starlink systems the eNTEGRA system s Ethernet Address and system name must be added to the Starlink configuration of each system In addition the Starlink software on each
80. 001 System Description Software Description Table 5 11 lists the settings of these AE parameters for GENIE Acquisition Millennium VG and eNTEGRA P amp R Table 5 11 DICOM AE Parameters for eNTEGRA Millennium VG Genie P amp R and Genie Acq Genie DICOM Field eNTEGRA P amp R Millennium VG re Genie P amp R Acquisition Station Name Host name or Host name Host name or Host name or descriptive containing max descriptive descriptive name contain 10 characters name contain name contain max 12 without spaces max 12 max 12 characters between them characters characters using only a z The first using only a z using only a z A Z 0 9 or character must A Z 0 9 or _ A Z 0 9 or _ beana z letter AE Title Host name in As assigned by Host name in Host name in upper case the network upper case upper case ENTEGRA administrator GENIEACQ GENIE Case Sensitive IP Address System s System s System s System s assigned IP assigned IP assigned IP assigned IP Address Address Address Address Port 104 104 2030 2030 eNTEGRA P amp R Service Manual 5 19 Rev 5 Direction 2263784 100 June 17 2001 Chapter 6 Software Installation 6 1 Overview This chapter provides detailed instructions for installing the basic software of the eNTEGRA system as well as its available options The instructions contained herein are provided in three sections as follows e Software
81. 01 Functional Checks Accessing a Remote Database 4 6 Accessing a Remote Database To be able to access a remote database for processing and review 1 Click on the Configuration button in the upper left corner of the Main screen In the opened User Preferences window click Advanced Configuration to open the ENTEGRA Configuration window 3 Form the Data Base tab select an on line remote station and click OK O ND wn At system message You need to restart eNTEGRA for changes to take effects click OK Click Apply in the User Preferences window Click X icon the upper left most button on the Main screen Click Partial to exit the eNTEGRA application Restart the application by double clicking the ENTEGRA icon on the Desktop When eNTEGRA is reloaded select the remote station from the Data Source drop down list on the Patient Selector and verify that the remote station s Patient Selector page is opened 4 7 Checking DICOM Transfer Din IN TR TN OS Click the Network tab Click on the Search Fetch tab Click on Search Fetch Template button In the opened Search Template window check the Dicom radio button Check the desired remote DICOM station Click the Search button The local data base of the remote station is displayed Highlight a study record its patient name type and patient ID Then click the Fetch button 8 Verify that the study was copied successfully to your local ar
82. 1 OPT000300 H3300TA 1 MAG Monitor 19 OPT000301 H3300TB Sony Optical Disk Drive 4 1 GB OPT000193 H2508LK 2 Isolation Transformer Non CE Version 2118082 1 Isolation Transformer CE Version 2118082 2 1 DASM LCAM self contained OPT000076 1 US Robotics MODEM Check with local 2135816 2 1 OLC for country specific models Power Cable 2119862 1 Modem Cable RS232 2123524 2 Monitor Cable VGA BNC 2210828 1 CAT 5 UTP Cable 5m 2215028 4 1 French Keyboard CP00024725F 1 Spanish Keyboard CP00024725E 1 eNTEGRA P amp R Service Manual 9 1 Rev 5 Direction 2263784 100 June 17 2001 Renewal Parts Software Table 9 1 Hardware FRU List Continued Description ELGEMS GEMS ToS Notes p Part Number Part Number code Portuguese Keyboard CP000247259 1 German Keyboard CP00024725D 1 Italian Keyboard CP000247252 1 Swedish Keyboard CP00024725S 1 9 2 Software Table 9 2 list the eNTEGRA software FRUs Table 9 2 Software Parts List a ELGEMS GEMS FRU Descripiion Part Number Part code Number eNTEGRA P amp R Software Release 1 5X LSW000195 1 English On line Documentation CD Windows NT package English OPT000338 H2600NT 1 eNTEGRA Accessories SW CD for LSW000154 2 Spanish Portuguese and French eNTEGRA Accessories SW CD for LSW000155 2 German Italian and Swedish eNTEGRA P amp R Service Manual 9 2 Rev 5 Direction 2263784 100 June 17 2001 Renew
83. 1 8 1 Taa E e i E E AE LANE A A EEA E E A EE OA E A aaa 8 1 8 2 eS li To KOOT gee aenee ae eRe N ere nserleve rrr e eT rcemrr orea 8 2 8 2 1 Operating System Installation Problems ccisscccscvesecasascsvscssreccassecsesiicezeeeeass 8 3 G22 eNTEGRA Installation Problems senosiose 8 3 8 2 3 Fost TAA FO cosine ncrianmennnnaamuninnamnn 8 4 8 2 4 Communicanon Problems deen eae ee er er e a 8 4 8 2 5 Pritts Probleme sssreineen n N EES 8 5 8 2 6 Codomes Stratus Cee E oreraa a E ees 8 6 8 2 6 1 Checking Sialis acns antennas 8 7 8 2 7 Releasing the System When it Gets SUCK c csciriisssitiissisrisssirisias 8 7 8 2 8 Restoring Pervious Configuration sssrinin 8 7 5 2 9 Creating Problem Reports iorsin 8 8 8 3 Merete Procede chee eee 8 9 ae Had Dove ioe i ees 8 9 8 3 1 1 RETIE n R R EO 8 9 8 3 1 2 Tools Regiei ecsauonins e 8 9 8 3 1 3 Te RONE erisa ees 8 9 8 3 1 4 Proca Oie apa A A E PU APE Senne wear ne 8 9 8 3 2 Tand Dove Kepteni eii N N 8 10 532A ETO ea E TEE N EAE EA 8 10 9 3 2 2 Tools Fe sac cissaevpntsnasachuisbaneanaiebanaaiaatabsmnainseiermuniaiebiaadins 8 10 8 3 2 3 Tine Regn nna 8 10 8 3 2 4 PCS nsnnannscnpnnmi eaa 8 10 Chapter 9 Renewal Paris csscnincscencisinrr nce 9 1 9 1 ETE ee E PE ces eis ee eee 9 1 9 2 SOORTE e E R N ae rere mre revs at rer 9 2 9 3 Documento ens aes ieee acento aide eatdcaenes aeaessoneeeoead 9 3 Appendix A Upgrading to ENTEGRA ssssssccccssscoccessssscoccessssoceesssosseceessosose A 1 A l Upgrading From XA Pert Syste
84. 1 Where to Look Topic Workstation Operation e e Source PC User s Guide Microsoft Windows NT Workstation Basics and Installation Version 4 0 eNTEGRA Operation eNTEGRA Operator s Manual Direction No 22666250 100 This Manual Chapter 4 Functional Checks Site Preparation pre Installation Check List Site Preparation Manual Direction No 2264704 100 Installing the System PC User s Guide This Manual Chapter 3 Installation System Configuration This Manual Section 3 8 Network Configuration This Manual Section 3 9 Configuring the Hardcopy Devices This Manual Section 3 10 Software Load from Cold This Manual Section 6 2 Software Load from Worm This Manual Section 6 3 Installing the Clinical Application Licences This Manual Section 6 4 eNTEGRA P amp R Service Manual Direction 2263784 100 2 2 Rev 5 June 17 2001 Introduction The eNTEGRA System 2 2 The eNTEGRA System The eNTEGRA platform is a Pentium based PC Table 2 2 lists the components that make up the eNTEGRA P amp R system Table 2 2 eNTEGRA System Components Description 19 or 21 High Resolution Color Monitor Comments PC Processor Unit Contains Pentium CPU Hard Disk Floppy Drive CD ROM Drive and optional Archive Optical Disk Keyboard 101 Key IBM PS 2 compatible 3 Button Mouse IBM PS 2 compatible Is
85. 1 Section 3 7 2 Verify no errors occur during boot up 5 Section 8 2 2 and that ENTEGRA application starts Total 10 3 7 2 Logging Into the System 1 Turn ON the Computer 2 When the Windows NT screen is displayed press the lt Alt gt lt Ctrl gt lt Del gt keys concurrently as prompted in the Begin Logon prompt 3 In the Logon Information dialog enter User name entegra Password entegra Click the OK button The ENTEGRA StartUp window with the version number will be displayed When the eNTEGRA application has been loaded the Main screen is dis played as shown in Figure 3 3 When activated the eNTEGRA application e Verifies that the eNTEGRA software and licenses were properly loaded in manufacturing e Initializes the system drivers for any SCSI peripherals DASM LCAM MFHD MF96 or Archive EOD added during the installation process e Verifies that all peripherals are alive and not hanging the SCSI bus 4 Once the eNTEGRA application starts verify that all licensed options are present such as ECToolbox QuantEM Aladdin PerfSPECTive IR QGSPECT etc eNTEGRA P amp R Service Manual 3 12 Rev 5 Direction 2263784 100 June 17 2001 Installation Initial System Power up Main Screen Processing amp Review Toggle Retrieve from Physician In box View Operator s On line Graphic Help Index Patient Selector Configuration Minimize Shutdown Processing Panel E
86. 1 USA If all the Product Locator cards are not returned then the system will not be configured correctly in the Product Locator database This will result in the manual distribution of any software upgrades eNTEGRA P amp R Service Manual 3 92 Rev 5 Direction 2263784 100 June 17 2001 Chapter 4 Functional Checks To verify that the Einstein system is working properly perform the following checks e Section 4 1 Checking the Color Maps on page 4 2 e Section 4 2 Processing Validation on page 4 3 e Section 4 3 Review Template Test on page 4 5 e Section 4 4 Checking the Default Hardcopy Device on page 4 6 e Section 4 5 Accessing the Optical Drive Archive on page 4 6 if installed e Section 4 6 Accessing a Remote Database on page 4 7 if available e Section 4 7 Checking DICOM Transfer on page 4 7 e Section 4 8 Checking the OSI Connectivity on page 4 8 e Section 4 9 Modem Connectivity Check on page 4 8 e Section 4 10 InSite Operation Check on page 4 9 eNTEGRA P amp R Service Manual 4 1 Rev 5 Direction 2263784 100 June 17 2001 Functional Checks Checking the Color Maps 4 1 Checking the Color Maps 1 SS BOY ey Stee ee yh 9 10 11 12 13 14 Click on the down arrow next to Sort in the control bar of the Patient Selector and click the Study Name entry Select a WB Bone study Click on the Load icon below the Patient Selector page Drop down the View
87. 10 DICOM Fa nconiantonndieiino irene 3 81 3 10 10 1 Gaar ei ieee eee ees 3 81 3 10 10 2 esi aiden i eee 3 82 3 10 10 3 Pronet Buer OE teen eee 3 83 3 10 10 4 EE ATE EP N E E E 3 84 3 10 10 5 Adding a New PET os cee sane 3 87 3 11 Taie Pee encena a 3 88 eA T a oe a 3 90 3 13 Rese WO NN asics decrees cancers R 3 90 3 14 E aer cides E cae eens saq tue tee sda wai oer eee 3 90 eNTEGRA P amp R Service Manual iii Rev 5 Direction 2263784 100 June 17 2001 Table Of Contents 3 14 1 ee ne ee eae 3 91 3 14 1 1 Dese 2 eee en ee np E a Pecan ere me 3 91 3 14 1 2 Procedure for Units with an Isolation Transformer eeeeeeees 3 91 3 14 1 3 Procedure for Units Without an Isolation Transformer 00 3 91 3 14 2 E E AE E EEN E E N aie 3 92 3 14 3 Complenne the PaperW Os rss SRE A 3 92 Chapter 4 Functional Checks secsessssssocccsssooeceesssscoecsssssooeesssssoceeessossececsssose 4 1 4 1 Checking the Color Misia uascctcinciermnenennaeen nan 4 2 4 2 Processite VYoldaANOlerpiriarik inaa Ea E ENEE EEES 4 3 4 2 1 Checking the Availability of Licensed Options sssessssssesssesesseeessressees 4 3 4 2 2 Runne an Appice E S 4 4 4 3 Meee Pee 1a cca N 4 5 4 4 Checking the Default Hardcopy Device siisiccsssissccsssrsnaaiearioccausiancateiansccusestnnns 4 6 4 5 Accessing the Opticdl Drive ALCS osc eeeednemaeniendaanes 4 6 4 6 Accessing a Remote Database oisinnean 4 7 4 7 Checkin DICOM Trini h o EN 4 7 4 8 Checking the O
88. 16x1 rn3m 952 16 3 lines TZ00 Prn3m 952 16 3 bdr lines 32 Prn3m 952 16 3 hmag 0 Prn3m 952 16 3 vmag 0 Prn3m 952 16 3 hmode 15 Prn3m 952 16 3 vmode 15 zone 4 Prn3m 952 16 4 frames 4 Prn3m 952 16 4 width 1024 Prn3m 952 16 4 height 1024 Prn3m 952 16 4 contrasts D D D D Edit to change Contrast 16x1 Prn3m 952 16 4 lines 1200 Prn3m 952 16 4 bdr lines 32 Prn3m 952 16 4 hmag 0 Prn3m 952 16 4 vmag 0 Prn3m 952 16 4 hmode 15 Prn3m 952 16 4 vmode 15 format 20 Prn3m 952 20 desc 20 on 1 4 frames on each of 5 zones Prn3m 952 20 zones 5 zone 1 Prn3m 952 20 1 frames 4 Prn3m 952 20 1 width 1024 Prn3m 952 20 1 height 1024 Prn3m 952 20 1 contrasts D D D D Edit to change Contrast 20x1 Prn3m 952 20 1 lines 960 Prn3m 952 20 1 bdr lines 32 Prn3m 952 20 1 hmag 0 Prn3m 952 20 1 vmag 0 Prn3m 952 20 1 hmode 15 Prn3m 952 20 1 vmode 15 zone 2 Prn3m 952 20 2 frames 4 Prn3m 952 20 2 width 1024 Prn3m 952 20 2 height 1024 Ea M 9525 204 contrasts D D D D Edit to change Contrast 20x1 rn3m 952 20 2 Lines 960 Prn3m 952 20 2 bdr lines 32 Prnsm 952 20 2 hmag 0 Prn3m 952 20 2 vmag 0 Prn3m 952 20 2 hmode 15 Prn3m 952 20 2 vmode 15 zone 3 Prn3m 952 20 3 frames 4 Prn3m 952 20 3 width 1024 Prn3m 952 20 3 height 1024 Prn3m 952 20 3 contrasts D D D D dit to change Contrast 20x1 Prn3m 952 20 3 lines 960 Prn3m 952 20 3 bdr lines 32 Prn3m 9
89. 2 vmode 15 format 4 Prn3m 952 4 desc Prn3m 952 4 zones 4 on 1 2 frames on each of 2 zones 2 zone 1 Prn3m 952 4 1 frames 2 Prn3m 952 4 1 width 1024 Prn3m 952 4 1 height 1024 Prn3m 952 4 1 contrasts D D Edit to change Contrast 4x1 Prn3m 952 4 1 lines 400 Prn3m 952 4 1 bdr lines 32 Prn3m 952 4 1 hmag 0 Prn3m 952 4 1 vmag 0 Prn3m 952 4 1 hmode 15 Prn3m 952 4 1 vmode 15 zone 2 Prn3m 952 4 2 frames 2 Prn3m 952 4 2 width 1024 Prn3m 952 4 2 height 1024 Prnam 952 4 2 contrasts D D edit to change Contrast 4x1 Prn3m 952 4 2 line s 400 Prn3m 952 4 2 bdr lines 32 Prn3m 952 4 2 hmag 0 Prn3m 952 4 2 vmag 0 Prn3m 952 4 2 hmode 15 Prn3m 952 4 2 vmode 15 format 6 Prn3m 952 6 desc 6 on 1 2frames on each of 3 zones Prn3m 952 6 zones 3 zone 1 Prn3m 952 6 1 frames 2 Prn3m 952 6 1 width 1024 Prn3m 952 6 1 height 1024 prn 95Z 6 1 contrasts D D jEdit to change Contrast 6x1 rn3m 952 6 1 lines T600 Prn3m 952 6 1 bdr lines 32 Prn3m 952 6 1 hmag 0 Prn3m 952 6 1 vmag 0 Prn3m 952 6 1 hmode TS Prn3m 952 6 1 vmode 15 Figure 3 6 HCdefaults win32 952 Lasercamera Section Part 2 eNTEGRA P amp R Service Manual Direction 2263784 100 3 42 Rev 5 June 17 2001 Installation Hardcopy Options zone 2 Prn3m 952 6 2 frames 2 Prn3m 952 6 2 width 1024 Prn3m 952 6 2
90. 3 10 6 3 Power up the systems in the following order to assure proper synchronization Konica Lasercamera DASM LCAM and then the eNTEGRA Log into eNTEGRA select the Formatter Static image from the Default Patient Calibration study and click the New icon located on the Patient Selector Control Bar Click the Camera tool in the Display Screen Click the Down Arrow in the Film dialog select the Konica Lasercamera and click Submit If a No image is printed refer to Section 8 2 for details on troubleshoot ing b An image is printed analyze the image and determine if additional adjustments are required Any adjustments for image quality will be made via the input module by the Konica Service Engineer Refer to Section 3 10 6 4 Repeat steps 5 through 7 until optimal film quality is achieved eNTEGRA P amp R Service Manual 3 63 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options 3 10 6 3 Lasercamera Connection This section provides details on how to interface the Konica Lasercamera to the eNTEGRA system via the DASM LCAM a Interface Wiring Figure 3 14 and Table 3 24 detail the interface between the eNTEGRA and the Konica Lasercameras using the DASM LCAM DASM LCAM O Ho o A Konica Figure 3 14 eNTEGRA to Konica Lasercamera Interconnection via the DASM LCAM Table 3 24 DASM LCAM to Konica Lasercamera Cable Summary
91. 3784 100 June 17 2001 Installation Hardcopy Options 3 10 7 3 Lasercamera Connection This section provides details on how to interface the Helios Lasercamera to the eNTEGRA system via the LAN a Interface Wiring Figure 3 15 and Table 3 26 detail the interface between the eNTEGRA and the Helios Helios Figure 3 15 eNTEGRA to Helios Interconnection Table 3 26 Helios Network Interface Cable Summary cable Description Pari Reference Run Source 1 eNTEGRA CAT 5 cable GEMS Section 5 1 4 2 10 Base T Transceiver for the Helios Sterling Helios Sterling Service Engineer 3 Helios CAT 5 Cable 4 10 Base T Hub GEMS b Interface Configuration The Helios must be configured to communicate with the eNTEGRA Table 3 27 summarizes the configuration parameters that need to be set on the Helios The Helios Sterling Service Engineer will be responsible for configuring and interfacing Lasercamera Details can also be found in the Helios Service Manual Table 3 27 Helios Lasercamera Interface Configuration Summary Parameter Setting IP Address for Helios IP Address assigned to Helios Netmask Optional Subnet Mask assigned to LAN Host IP Address eNTEGRA s IP Address eNTEGRA P amp R Service Manual 3 68 Rev 5 Direction 2263784 100 June 17 2001 Ins
92. 52 20 3 hmag 0 Prn3m 952 20 3 vmag 0 Prn3m 952 20 3 hmode 15 Prn3m 952 20 3 vmode 15 Figure 3 9 HCdefaults win32 952 Lasercamera Section Part 5 eNTEGRA P amp R Service Manual Direction 2263784 100 3 45 Rev 5 June 17 2001 Installation Hardcopy Options zone 4 Prn3m 952 20 4 frames 4 Prn3m 952 20 4 width 1024 Prn3m 95 0 4 height 1024 E Prn3m 952 20 4 contrasts D D D D Edit to change Contrast 20x1 Prn3m 952 20 4 lines 960 Prn3m 952 20 4 bdr lines 32 Prn3m 952 20 4 hmag 0 Prn3m 952 20 4 vmag 0 Prn3m 952 20 4 hmode 15 Prn3m 952 20 4 vmode 15 zone 5 Prn3m 952 20 5 frames 4 Prn3m 952 20 5 width 1024 Prn3m 952 20 5 height 1024 Prn3m 952 20 5 contrasts D D D D lt Edit to change Contrast 20x1 Prn3m 952 20 5 lines 960 Prn3m 952 20 5 bdr lines 32 Prn3m 952 20 5 hmag 0 Prn3m 952 20 5 vmag 0 Prn3m 952 20 5 hmode 15 Prn3m 952 20 5 vmode 15 Figure 3 10 HCdefaults win32 952 Lasercamera Section Part 6 eNTEGRA P amp R Service Manual Direction 2263784 100 3 46 Rev 5 June 17 2001 Installation Hardcopy Options 3 10 3 Kodak Laser Cameras Configuration 3 10 3 1 Overview Note This section provides details on how to connect the Kodak family of Lasercameras to the eNTEGRA system using the 952 interface and how to configure both the eNTEGRA and Lasercamera to produce good quality films This includes th
93. 6 3 6 2 2 Disconnecting Existing Optical Disk Drives if Applicable 0 00 6 4 6 2 3 Setting thie System BIOS sccniscaksimacsreinnaueunmenneninamnannnes 6 4 6 2 4 Installing the Windows NT Operating System seseeeseseeeeseeesseesseesseseee 6 5 6 2 5 Installing Windows NT Networking cas win cccecdasossoiernasscaanannenraacsannacemones 6 7 6 2 6 Veneta Minne Service Pack Gaerne 6 10 62 7 Tnstaline the Display DIN e E uennreananin a 6 11 6 2 8 Adjusting the Display Properties sssicccisisczesssasacieraiapierssssnzeatsasataasisdvarinisnns 6 12 6 2 9 TSG the Sound DAVET erases 6 13 6 2 10 es Sysiem UPU srra O 6 13 6 2 10 1 seling the Date Formi eener E 6 13 6 2 10 2 Setting the Application Event Viewer LoggingS ccceeseeesseeeeees 6 14 6 2 10 3 petting the Task Bar Properties cic cicciassacicasarerairemensemensneonns 6 14 6 2 10 4 Oe Te Vier I ct Gannnnnineannaunwanenis 6 14 6 2 11 Installing Internet Explorer S scacissscansedmaseniemdenneds 6 15 6 2 12 Installing RAS Modem and TCP IP Printing seeeeceeeeeseeeeeeteees 6 16 6 2 13 UE ROU bata te FTP Seri Enea er ne perry trot mE Ener vy Seer rece Tt 6 18 6 2 14 Formatting Dive Das NTFS rrenaren 6 19 6 2 15 Installing the eNTEGRA Application and Its Accessory Components 6 20 6 2 16 Tis ite TAS AO sasonsonnneran e Ea 6 21 6 2 16 1 Installation of the Command Line TeMet iciiscisisiteaiineinsiiia nave 6 21 6 2 16 2 Configuring ATAMAN Telnet to include eNTEGRA as uset
94. 952 fmt n contrast parameter lt Ctrl gt lt F gt Prn3m 952 fmt n contrast lt Enter gt The cursor will be placed on the p of the following line Prn3m 952 1 1 contrasts D 9 Press the key until the cursor is over the D then overtype it by 20 10 Press lt F3 gt to go to the next line containing the Prn3m 952 fmt n contrast parameter 11 Repeat steps 9 and 10 until the contrast setting for each frame in each format definition is changed There are a total of 25 frame definitions Note Refer to Figure 3 5 Figure 3 6 Figure 3 7 Figure 3 8 Figure 3 9 and Figure 3 10 in Section 3 10 2 5 for a listing of this section of the HCdefaults win32 file 12 Save the changes and quit the notepad editor by selecting File Save File Exit 13 Type the following to copy the modified HCdefaults win32 file in the config directory copy HCdefaults win32 HCdefaults win32 bak lt Enter gt 14 Go back to the eNTEGRA Main Screen click the X button and in the System Shutdown dialog click the Full button 15 Restart the eNTEGRA eNTEGRA P amp R Service Manual 3 52 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options 3 10 3 4 Image Quality Configuration Note Note Kodak s implementation of the 952 protocol differs from that of the standard 3M Lasercamera This result in the following differences in image quality configuration The Prn3m 952 fmt n contrast paramet
95. Although any windows compatible printer will work the best results are achieved using a PostScript compatible printer The eNTEGRA system interfaces the PostScript printer either through its parallel port or the network port using TCP IP network protocol Section 3 10 9 2 provides the basic procedure for installing a Windows PostScript printer to be interfaced to eNTEGRA Section 3 10 9 3 provides details on the physical interface between the PostScript printer and the eNTEGRA 3 10 9 2 Basic Procedure The procedure below provides guidelines and an example of installation sequence for a windows PostScript compatible printer There may be some variations in the instructions depending on the printer manufacturer For additional information and troubleshooting refer to the manufacturer s printer documentation 1 Connect the printer to eNTEGRA refer to Section 3 10 9 3 a If the parallel port interface will be used connect the printer parallel port cable to the eNTEGRA parallel port b If the network interface will be used connect the printer to the local network refer to the printer documentation An IP Address will also be need for the printer 2 Install the printer software according to the interface use as follows e Section 3 10 9 2 1 Software Installation for a Printer Interfaced via the Parallel Port on page 3 78 e Section 3 10 9 2 2 Software Installation for a Printer Interfaced via the Network Port on pa
96. Ethernet Adapter o o NIC AnS a g B S008 i of 3 ys D S E Power S f O Voltage Adapter aS Laser Printer a Power Isolation Transformer 5 o i JO v a 5 Ge Grounded 110 V 220 V LAN Socket Grounded 110 V 220 V Telephone AC Wall Outlet AC Wall Outlet Socket Figure 5 1 System Block Diagram eNTEGRA P amp R Service Manual 5 2 Rev 5 Direction 2263784 100 June 17 2001 System Description Hardware Description 5 1 2 Hardware Components Table 5 1 Hardware Components Unit PC Tower Component Motherboard Specification Pentium III Processor 512 Mb RAM 512 Kb Cache Ultra 2 SCSI Controller SCSI III to SCSI Il Adapter Cable Enhanced IDE Controller Soundblaster 16 Audio Interface 25 Pin Parallel Port Two 9 pin serial ports Five 32 bit PCI expansion slots NVIDIA TNT2 16 MB on board Video 3Com 905C on board LAN Controller Hard Drive 18 Gb Ultra 2 SCSI drive Flexible Disk 1 44 Mb IDE Floppy drive CD ROM x48 IDE CDROM EOD optional Sony 4 1 GB Monitor Type 19 Color Monitor Resolution 1280 x 1024 User Interface Keyboard 101 Key PS 2 Mouse 3 button PS 2 Modem 3Com Currier V Everything For North America only Motorola Codex For Europe Isolation Transformer As per the local Regulatory Kit DASM LCAM Adaptor for old Laser ha
97. Installation of VNC Server 1 16 17 18 Click left on the Start icon on the Tasks Bar and select Programs gt Command Prompt In the opened Command Prompt window a Type cd insite vnc lt Enter gt b Type gzip d vnc lt Enter gt c Type tar xvf vne lt Enter gt This will extract some files d Type exit lt Enter gt to close the Command Prompt window Double click on My Computer Double click on the C icon Double click on the insite folder Double click on the vne folder Double click on the vne_x86_win32 folder Double click on the winvne folder Double click on the Setup exe icon Click OK in the opened WARNING window Click Next in the opened Welcome window Click Yes in the opened Software License Agreement window Click Next in the opened Choose Destination Location window Click Next in the opened Select Program Folder window When the Setup Complete window appears If prompted to restart the computer select No will restart my computer later Then or otherwise click Finish Click the Start button on the Task Bar at the bottom of the screen and select the Run entry Type winvne lt Enter gt in the command line If the WinVNC Current User Properties window appears type insite in the password field then click OK Note when typing insite be sure that the lt Caps Lock gt button is OFF 19 Click on Start gt Find Fi
98. Manual 5 12 Rev 5 Direction 2263784 100 June 17 2001 System Description Software Description 5 2 3 Database The eNTEGRA system uses a custom database Currently there are no simple tools available to access the database outside the eNTEGRA application The database resides in the D Database directory and has a capacity of 2 3 GB The eNTEGRA application accesses the database via the database server 5 2 3 1 Database Structure e Patient e Study e Series e Data Set e Multiframe Image e Curves e ROI e Templates 5 2 4 System Accounts Table 5 8 lists the accounts and associated passwords defined on the system Table 5 8 Default Passwords Account Definition Password administrator eNTEGRA Super User account Used for maintaining the system Customer defined eNTEGRA The eNTEGRA P amp R user account default ENTEGRA insite Insite account Used by OLC to remotely log in to system TBD eNTEGRA P amp R Service Manual 5 13 Direction 2263784 100 Rev 5 June 17 2001 System Description Software Description 5 2 5 eNTEGRA Supported Networks There are two separate network protocols provided TCP IP a standard network protocol suite included with the NT workstation used for DICOM communication eNTEGRA Remote Database Interfile file transfers Insite remote connectivity Network printing S Oh e S Starlink a customized netwo
99. Manual Rev 5 P N 2263784 100 vii June 17 2001 Notes eNTEGRA P amp R Service Manual Rev 5 P N 2263784 100 viii June 17 2001 TABLE OF CONTENTS SECTION Chapter 1 Safety Guidelines and Regulatory cssscceeees 1 1 leneral Sale GUANO S eres 1 2 E A E A E ea ed E E A teed E AA 1 2 1 General Maraid s oden E ee Oe a Lo Electrical Precaution saisccenssiscdccoraisccatiasinicorrasscatasiicsdaatesraninns 1 4 Installation Safety HIGSMlCS neds eerscreeniienreieiereniees 1 5 Satety Def ONS sanean 1 6 TEE Sy IIIS a 1 7 Regulatory formaton eon ee ne eee a Lae i AN ree eee Liz CE CONTON res Isia USA Rewa ONS eninonnnnnnnr a Chapter 2 Introduction ssccctccsccrccrmesticccicicenricirceeeeetins Zul How to Use Mis Mamah crne A11 Other Documenting se a 212 Where to LAs ss cadences cee nictepeareeaneaacens Do THSeNTEGRA Sylen O NE edal Catalog Product Siete cc ssiactescssasoccasiaticcananaenaisaieres Chapter 3 Installati n seratcstsccs sasicscccceenciesescadioncdisscenseecteancnmeiesees 3 1 B AOAN AE E A NEE E add How to Use This Chaple ocscrsensenesrcnancnniannn cS Pei 0 ee cei LLS General Pa scones a ce De A Special Tools and Pix Gare sssini unr 3 1 3 2 Sene ANEDOTA roser 3133 Pre Installation Check List Completed 3 1 3 4 Compatible OPOS eors 31 33 Recording Installation Time iccarssccessarcsensseccauiiarsereasis 3 1 4 Installation Flow ae iene ue reece ee eee Aed Fac king Litenes dda Damor
100. NTEGRA as user 1 Double click on My Computer minify eNTEGRA application if necessary Double click on Control Panel 3 Double click on Ataman TCP R L Services Select the Users tab in the opened Ataman TCP Remote Login Services window Click Add User To create an eNTEGRA user for telnet purposes a Inthe User Name field type entegra b Inthe NT User Name field type entegra c Inthe NT User Domain field type only put a period Click OK 8 Click OK in the Ataman TCP Remote Login Services window Close the Control Panel eNTEGRA P amp R Service Manual 6 22 Rev 5 Direction 2263784 100 June 17 2001 Software Installation Software Load From Cold For Dell OptiPlex GX200 6 2 16 3 Verifying InSite user accounts and passwords 1 Click left on the Start icon on the Tasks Bar and select Programs gt Administrative Tools common gt User Manager In the opened User Manager window double click on the insite entry In the opened User Properties a Click the checkbox next to Password Never Expires b If necessary uncheck the box next to User Must Change Password at Next Logon Verify that all other boxes are unchecked then click OK In the opened User Manager window double click on the Pinsite entry In the opened User Properties a Click the checkbox next to Password Never Expires b If necessary uncheck the box next to User Must Change Password at Next Logon
101. NY 5 25 re writable multi functional optical disk drive Note does not support reading data archived using the PIONEER DE UH7101 drive H2508LG Digital Laser Camera Interface DASM LCAM Provides host control and digital 3M 952 interface to supported lasercameras Separate stand alone unit H2600NJ 128 MB Memory Upgrade Software H2600LE ECToolbox new CEqual processing with 5 databases EGS and 3 D PerfSPECTive 2nd 3rd licence H2600NC 4th Licence H2600NE H2600LC ECToolbox Light New CEqual with two databases 1 day MIBI and 2 Day MIBI 2nd 3rd licence H2600ND 4th Licence H2600NF H2600RK Functional Anatomical Mapping Fusion H2600LB QuantEM Emory Renal Quantification with syringe holder and gates adapter H2600MB H2600LK QGS Quantitative Gated SPECT analysis Cedar Sinai package H2600WB QPS Quantitative Perfusion SPECT Cedar Sinai package H2600LM 3 D Volume Rendering and Surface Shading H2600LP Aladdin Advanced Software H2600LR Iterative Reconstruction including MLEM OSEM and COSEM IR algorithms for SPECT and CoDe H2600WC OSI Connectivity used to connect StarCam and APEX SP systems to the eNTEGRA H2600LT CT MR Display DICOM Import of CT MR Images via LAN H2600LS Transfer of Interfile and DICOM Part 10 files via WAN LAN eNTEGRA P amp R Service Manual 2 5 Rev 5 Direction 2263784 100 June 17 2001 Chapter 3 Installation This chapter provides detailed instructions for insta
102. Optical Disk to 1 Refer to the OEM documentation sent with the drive Not Use proper ESD procedures when handling the Optical Drive and working in the 2 PC Tower 4 Insert the Optical Disk into the empty slot in the PC Tower and fasten in place using the screws from the slot cover Refer to the PC User s Guide 5 Connect the internal power cable and Narrow SCSI cable to the connectors on the back of the drive All connectors are keyed to ensure that they are inserted correctly 6 Reassemble the PC Tower and reconnect all cables eNTEGRA P amp R Service Manual 7 1 Rev 5 Direction 2263784 100 June 17 2001 System Upgrade Adding an Optical Drive 7 1 2 System Configuration and Test 1 Power ON the computer The Green LED on the drive should illuminate during it s power up test Verify that the optical disk is identified during the Boot up sequence Open the eNTEGRA application 3 Click on the Configuration button In the opened User Preferences window click Advanded Configuration In th opened ENTEGRA Configuration window click the Archive tab In the Archive tab check Enable Archive Functionality and SONY Pioneer MOD Drive and click OK Click Shutdown Inthe opened System Shutdown window click Powerdown Restart the eNTEGRA application 10 Verify peripheral operation Refer to Chapter 4 eNTEGRA P amp R Service Manual 7 2 Rev 5 Direction 2263784 100 June 17
103. Options on page B 12 a a ee When done proceed to Installing Internet Explorer 5 on page B 13 eNTEGRA P amp R Service Manual 10 Rev 5 Direction 2263784 100 June 17 2001 Setting System Options B 9 1 Setting the Date Format 1 Click left on the Start icon on the Tasks Bar and select Setting gt Control Panel Onthe Control Panel window double click on the Regional Settings icon 3 Click on the Date tab 4 Click the down arrow at the Short data style field select the format MM dd yyyy and click OK B 9 2 Setting the Application Event Viewer Loggings 1 Click left on the Start icon on the Tasks Bar and select Programs gt Administrative Tools common Event Viewer 2 Click the Log option in the Menu Bar and select the Application entry 3 Click the Log option in the Menu Bar and select the Log settings entry 4 In the Event Log Settings window check the Overwrite Events as Needed field Logs 5 Click OK 6 Close the Event Viewer window B 9 3 Setting the Task Bar Properties 1 Click right on an empty place of the Task Bar and select the Properties entry 2 In the opened Task Bar Properties window uncheck the Always on top option 3 Click OK to close the Task Bar Properties window eNTEGRA P amp R Service Manual 11 Rev 5 Direction 2263784 100 June 17 2001 Setting System Options B 9 4 Setting the Virtual Memory Click right on My Computer icon and select the
104. P amp R Service Manual 1 7 Rev 5 Direction 2263784 100 June 17 2001 Chapter 2 Introduction In this chapter you will find the following information e Section 2 1 How to Use this Manual on page 2 1 o Section 2 1 1 Other Documentation on page 2 1 o Section 2 1 2 Where to Look on page 2 2 e Section 2 1 2 Where to Look on page 2 3 o Section 2 2 1 Catalog Product Structure on page 2 3 2 1 How to Use this Manual This Class A Service documentation set provides e eNTEGRA P amp R specific service information e Direction to appropriate service documentation included with the eNTEGRA PC Workstation The beginning of each section in this manual contains a steering guide which lists the topics covered and where to look for the information Some of the information is found within this manual and other information is found in documentation supplied by manufacturers of the ENTEGRA System components 2 1 1 Other Documentation Each system includes the following manuals e PC User s Guide containing information on installing and troubleshooting the PC Locate this manual and keep it with this manual e Microsoft Windows NT Workstation Basics and Installation Locate this manual and keep it with this manual e Monitor s User Guide e Modem User s Guide eNTEGRA P amp R Service Manual 2 1 Rev 5 Direction 2263784 100 June 17 2001 Introduction How to Use this Manual 2 1 2 Where to Look Table 2
105. Peer Web Server and click OK In the Installed from input field enter D i386 where D is your CD drive and click OK On the opened Microsoft Peer Web Services Setup dialog click OK In the opened Options list deselect all options except FTP Service and Internet Service Manager then click OK 8 Click Yes to create the prompted directory 10 11 12 13 14 15 16 I7 18 19 In the FTP Publishing Directories input field type C Insite and click OK If required acknowledge by clicking Yes to create the Insite directory When the installation has been complete successfully click OK Click Close in the Network dialog Click Start on the task bar and select Programs Microsoft Peer Web Services Internet Service Manager Double click the Computer Name entry to open the FTP Service properties for entegra dialog On the Service tab uncheck Allow only anonymous connections and confirm by clicking Yes Click the Directories tab select the displayed entry click Edit Properties check click the Write property then click OK Click Add enter C in the Directory field enter C in the Alias field click the Write checkbox located at the bottom of the screen and click OK Click Add enter D in the Directory field enter D in the Alias field click the Write checkbox located at the bottom of the screen and click OK Click OK and close the Micr
106. Press lt C gt to create a new partition Delete the number displayed by pressing lt Backspace gt Type 3000 and press lt Enter gt Press the lt gt key press lt C gt and accept the defaults by pressing lt Enter gt While the Ist partition is highlighted press lt Enter gt to install Windows NT on drive C monaogep eNTEGRA P amp R Service Manual 3 Rev 5 Direction 2263784 100 June 17 2001 Installing the Windows NT Operating System 13 Install Windows NT as follows a Inthe opened dialog use the lt gt key to highlight the line Format using NTFS and press lt Enter gt Drive C will be formatted This may take several minutes b When prompted press lt Enter gt twice to start copying the NT files c Upon system prompt remove the Windows NT CD and the floppy d When prompted press lt Enter gt to reboot 14 After reboot the installation continues followed by another automatic reboot 15 When prompted insert the NT installation CD into the CD drive and click OK 16 Proceed to Installing Windows NT Networking on page C 5 eNTEGRA P amp R Service Manual 4 Rev 5 Direction 2263784 100 June 17 2001 Installing Windows NT Networking C 3 Installing Windows NT Networking 1 In the Windows NT Setup window click Next to continue 2 Inthe opened Setup Options window select Typical and click Next 3 In the opened Name and Organization window type in your
107. Project Resources Config Connectivity eNTEGRA P amp R Service Manual Direction 2263784 100 8 8 Rev 5 June 17 2001 Troubleshooting and Repair Replacement Procedures 8 3 Replacement Procedures 8 3 1 Hard Drive Swapping 8 3 1 1 Overview The PC Tower FRU includes a hard drive If the hard drive in the defective PC is not defective it can be swapped with the drive in the replacement unit This eliminates having to do a load from cold on the system or reassigning the Host ID 8 3 1 2 Tools Required The following tools are required to perform the upgrade e Field ESD Kit e A 2 Phillips Screw Driver 8 3 1 3 Time Required This repair takes approximately 30 minutes to complete 8 3 1 4 Procedure 1 Power down the GENIE 2 Remove hard drive from defective PC Refer to How to Install Accessories section of the PC User s Guide Install the hard drive from the defective PC into the replacement PC 4 Install hard drive from the replacement PC into the defective PC Power up the system and verify proper operations eNTEGRA P amp R Service Manual 8 9 Rev 5 Direction 2263784 100 June 17 2001 Troubleshooting and Repair Replacement Procedures 8 3 2 Hard Drive Replacement 8 3 2 1 Overview A load from cold will need to be performed on the system once the drive is replaced 8 3 2 2 Tools Required The following tools are required to perform the upgrade e Field ESD Kit e A 2 Phillips Screw Driver
108. Properties entry Click on the Performance tab Click the Change button With Drive C highlighted change the Initial Size MB to 540 Change the Maximum Size MB to 560 Click the Set button Click OK and close the Virtual Memory window Close the System Properties window OE as ol ON SM SE Oa Ds T When prompted click Restart to reboot the system B 9 5 Setting the View Options 1 When the system reboots and prompts press lt Alt gt lt Ctrl gt lt Del gt and login into the system with Username entegra Password entegra 2 Double click My Computer icon 3 Inthe opened My Computer window click the View option in the Menu Bar and select the Options entry 4 In the Options window click the Folder tab 5 Click the radio button next to Browse folder by using a single window that changes as you open each folder then click the Apply button 6 Click the View tab in the Options window 7 Click the radio button next to Show all files option 8 Uncheck the option Hide file extensions for known file types click Apply and close the Options window 9 Close My Computer window eNTEGRA P amp R Service Manual 12 Rev 5 Direction 2263784 100 June 17 2001 Installing Internet Explorer 5 B 10 Installing Internet Explorer 5 1 For the English version skip to Step 2 below For other languages replace the eNTEGRA application CD with the eNTEGRA Accessories Software CD Double
109. Q GE Medical Systems Technical Publications P N 2263784 100 Revision 5 eNTEGRA P amp R Nuclear Imaging System System Service Manual Printed for g GE Medical Systems GE Medical Systems telex 3797371 P O Box 414 Milwaukee Wisconsin 53201 U S A Asia Pacific Latin America North America GE Medical Systems Europe Telex 698626 283 rue de la Miniere B P 34 78533 Buc Cedex France COPYRIGHT 2000 2001 BY ELGEMS LTD Acquisition and or processing software and the related documentation are confidential and proprietary information of ELGEMS Ltd Only licensees of ELGEMS Ltd have a right to use the information contained herein Only licensees specifically granted copy and or transfer rights have the right to copy and or transfer the information Any unauthorized use disclosure assignment transfer or reproduction of this confidential information will be prosecuted to the full extent of the Law DISCLAIMER ELGEMS Ltd shall not be liable nor obligated in any manner in respect of bodily injury and or property damage arising from the use of this software if such use is not in strict compliance with instructions and safety precautions contained in the relevant operating manuals and in all supplements thereto in all product labels and according to all terms of warranty and sale of this software nor if any change not authorized by ELGEMS Ltd is made to the software contained herein WARNING User provided prog
110. R Service Manual 4 Rev 5 Direction 2263784 100 June 17 2001 Installing Windows NT Networking 17 18 19 20 21 22 23 24 25 26 2T 28 29 30 c Browse to D Drivers and double click on Driver exe For AMD PCnet network adapter insert the Windows NT CD into the CD ROM drive Click with the right mouse button on the Network Neighborhood icon on the desktop Click on the Properties entry Click Yes to confirm that networking is to be installed Click Next In the Network window click on Adapters tab Click Add For AMD PCnet network adapter highlight the AMD PCNET Family Ethernet Adapter and click OK e For 3Com 905B network adapter click on Have disk type in the path C Drivers 3Com and click OK twice In the Network window click on Protocols tab Click Add and highlight TCP IP Protocol and click OK Upon the message If there is a DHCP click NO In the opened Microsoft TCP IP Properties window click the IP Address tab and a Type in your IP address as defined in the pre installation checklist b If relevant type in your Subnet Mask c Ifrelevant type in your Default Gateway address as defined in the pre installation checklist If relevant click the DNS tab and type in the DNS IP address defined in the pre installation checklist If relevant click the WINS tab type in the Windows Server primary and secondary IP addre
111. S DO NOT ATTEMPT TO SERVICE THE EQUIPMENT UNLESS THIS SERVICE MANUAL HAS BEEN CONSULTED AND IS UNDERSTOOD FAILURE TO HEED THIS WARNING MAY RESULT IN INJURY TO THE SERVICE PROVIDER OPERATOR OR PATIENT FROM ELECTRIC SHOCK MECHANICAL OR OTHER HAZARDS CE MANUEL DE MAINTENANCE N EST DISPONIBLE QU EN ANGLAIS SI LE TECHNICIEN DU CLIENT A BESOIN DE CE MANUEL DANS UNE AUTRE LANGUE QUE L ANGLAIS C EST AU CLIENT QU IL INCOMBE DE LE FAIRE TRADUIRE NE PAS TENTER D INTERVENTION SUR LES EQUIPEMENTS TANT QUE LE MANUEL SERVICE N A PAS ETE CONSULTE ET COMPRIS LE NON RESPECT DE CET AVERTISSEMENT PEUT ENTRAINER CHEZ LE TECHNICIEN L OPERATEUR OU LE PATIENT DES BLESSURES DUES A DES DANGERS ELECTRIQUES MECANIQUES OU AUTRES eNTEGRA P amp R Service Manual Rev 5 P N 2263784 100 v June 17 2001 ATEN O AVVERTENZA AVISO DIESES KUNDENDIENST HANDBUCH EXISTIERT NUR IN ENGLISCHER SPRACHE FALLS EIN FREMDER KUNDENDIENST EINE ANDERE SPRACHE BEN TIGT IST ES AUFGABE DES KUNDEN F R EINE ENTSPRECHENDE BERSETZUNG ZU SORGEN VERSUCHEN SIE NICHT DAS GER T ZU REPARIEREN BEVOR DIESES KUNDENDIENST HANDBUCH NICHT ZU RATE GEZOGEN UND VERSTANDEN WURDE WIRD DIESE WARNUNG NICHT BEACHTET SO KANN ES ZU VERLETZUNGEN DES KUNDENDIENSTTECHNIKERS DES BEDIENERS ODER DES PATIENTEN DURCH ELEKTRISCHE SCHL GE MECHANISCHE ODER SONSTIGE GEFAHREN KOMMEN ESTE MANUAL DE SERVI O S DISPON VEL EM INGL S CASO O PROVEDOR DE SERVI
112. SCP Nuclear Storage SOP Class Nuclear images can be received and stored in the database from a system that supports the Nuclear Storage SOP Class in the SCU role Secondary Capture Storage SOP Class Secondary Capture images can be received and stored in the database from a system that supports the Secondary Capture Storage SOP Class in the SCU role CT Storage SOP Class CT images can be received and stored in the database from a system that supports the CT Storage SOP Class in the SCU role MR Storage SOP Class MR images can be received and stored in the database from a system that supports the MR Storage SOP Class in the SCU role Patient Study Root Query SOP Class Allows remote systems that supports the Patient Study Root Query SOP Class in the SCU role to query the database Patient Study Root Fetch SOP Class Allows remote systems that supports the Patient Study Root Fetch SOP Class in the SCU role and the Nuclear Storage SOP Class or Secondary Capture Storage SOP Class in the SCP role to retrieve image data from the database DICOM is now the preferred communication protocol between the cameras GENIE Acquisition and Millennium VG and the eNTEGRA P amp R system Processing and review of data on remote eNTEGRA Genie P amp R systems is carried out directly in the remote data base On the other hand transfer of data between eNTEGRA P amp R systems or between eNTEGRA and GENIE P
113. SI Connechvify asemiin a ne 4 8 4 9 Modem Comec vity Cheek srersurnneeni n a E 4 8 4 10 mate Operat TOE tcnccicnmiinendanousaunnnomeoniammaene 4 9 Chapter 5 System Description sesssesssssocecessoocccecssoceccesssscoeesssssoceeesssooececssssse 5 1 5 1 Hardware Descnpthon ssiriniinriicrik 5 2 sA M System Blok Matii 5 2 eT E Hardware C I MS mesca R 5 3 5 1 3 Cabling and LINKINE rss e A E 5 4 3 1 3 1 DASWLLCAM Connectors Piri OUt asics tcsucce steer artceuatsnanccucaseieioens 5 4 5 13 2 SCSI Address Assie NMEN esiisa iaaea 5 6 5 1 4 W EOD a A bua dass wanes daa alannah 5 7 5 1 4 1 Jumpers SOU atime 5 7 5 1 4 2 DIP Sw eE ee NE 5 8 5 1 5 PASONG A N eee ne ee rere cant E neers Were nner eee 5 9 Due ee Deepan ee eee 5 10 Sad ON SUNO a E E 5 10 5 2 2 License Rey Sfecisnnonserninon ie TE 5 12 323 Lee cr ees aan ae 5 13 IZo Database SUCE ie csun cuielacus eunnecuen meatal 5 13 5 2 4 Syse PC NII S osis ei S E O 5 13 oe e NTEGRA Supported Netw acs ecw temmnicormseraneeern cremains 5 14 5 2 6 DICOM ordrin a nine peer nentew T ia 5 15 Chapter 6 Software Installation sssooecossoococecessoccocssssscoccsssssosecesssosesecsssose 6 1 eNTEGRA P amp R Service Manual iv Rev 5 Direction 2263784 100 June 17 2001 Table Of Contents 6 1 Ce icici deinen ania anes 6 1 6 2 Software Load From Cold For Dell OptiPlex GX200 eee eeeseeeeeteeeeeee 6 2 6 2 1 PE eise A E anemone 6 2 6 2 1 1 Tune eee eee ie 6 2 6 2 1 2 Procedure ete cnt
114. Setting System Options Set the following operating system configurations in the given order Setting the Date Format on page C 11 Setting the Application Event Viewer Loggings on page C 11 Setting the Task Bar Properties on page C 11 Setting the Virtual Memory on page C 11 Setting the View Options on page C 12 ON Os ee re When done proceed to Installing Internet Explorer 5 on page C 12 eNTEGRA P amp R Service Manual 10 Rev 5 Direction 2263784 100 June 17 2001 Setting System Options C 8 1 Setting the Date Format 1 Click left on the Start icon on the Tasks Bar and select Setting gt Control Panel On the Control Panel window double click on the Regional Settings icon Click on the Date tab Click the down arrow at the Short data style field select the format M d yyyy and click OK C 8 2 Setting the Application Event Viewer Loggings 1 Click left on the Start icon on the Tasks Bar and select Programs gt Administrative Tools common gt Event Viewer 2 Click the Log option in the Menu Bar and select the Application entry 3 Close the Event Viewer window C 8 3 Setting the Task Bar Properties 1 Click right on an empty place of the Task Bar and select the Properties entry In the opened Task Bar Properties window uncheck the Always on top option Click OK to close the Task Bar Properties window C 8 4 Setting the Virtual Memory NOs GO ON te Oe as Clic
115. Source Reference DB25 to Printer s Parallel Port Customer Printer s Documentation eNTEGRA P amp R Service Direction 2263784 100 Manual 3 80 Rev 5 June 17 2001 Installation Hardcopy Options 3 10 10 DICOM Print 3 10 10 1 Overview This section provides details on how to connect and configure the various DICOM printers that eNTEGRA P amp R supports The eNTEGRA P amp R hardcopy server now supports printing toa DICOM Printer DICOM Print Management SCP via the local network using the TCP IP network protocol The hardcopy server represents a single Application Entity AE that is separate from the one used for image transfer It provides standard conformance to the following DICOM 3 0 SOP Classes as a SCU e Basic Grayscale Print Management SOP Class e Basic ColorPrint Management SOP Class DICOM printers are configured in the Printers tab of the eENTEGRA Configuration window and the HCdefaults win32 file in the D einstein einstein_project resources directory The following DICOM printers are validated e Imation 8300 DCMI8300 e Imation 8700 Print Server DCMI8700 e AGFA Drystar 2000 Colour and Black and White DCMA2KCL amp DCMA2KBW e Codonics 1660m DCMcod Other DICOM printers may be compatible with eNTEGRA but will need to be manually configured Refer to section Section 3 10 10 5 for details Section 3 10 10 2 provides the basic procedure for interfacing configuring the printers to
116. TEGRA as user on page 6 22 e Verifying InSite user accounts and passwords on page 6 23 e Re installation of Service Pack 6a on page 6 24 e Installation of VNC Server on page 6 25 Currently InSite does not work on systems with Windows NT Operating Systems in Portuguese 6 2 16 1 Installation of the Command Line Telnet 1 Insert the eNTEGRA Software Disk CD ROM into the CD ROM drive 2 Double click on the My Computer icon on the Desktop 3 Double click on the CD ROM icon 4 Double click on the Options folder 5 Double click on the cmdtelnet folder 6 Double click on the Setup exe icon 7 Click Next in the Welcome window 8 Click Yes in the License Agreement window 9 Click Next in the Readme Information window 10 Click Browse in the Choose Destination Directory window 11 Select the C insite directory as follows a Double click on the C folder b Double click on the Insite folder this should update the top field to read C insite 12 Click OK 13 Click Next in the Choose Destination Directory window 14 Click Next in the Select Program Folder window 15 Click Next in the Start Copying Files window 16 Uncheck View Readme and click Finish in the Setup Complete window eNTEGRA P amp R Service Manual 6 21 Rev 5 Direction 2263784 100 June 17 2001 Software Installation Software Load From Cold For Dell OptiPlex GX200 6 2 16 2 Configuring ATAMAN Telnet to include e
117. Tab of the Config Utility eNTEGRA P amp R Service Manual Direction 2263784 100 3 85 Rev 5 June 17 2001 Installation Hardcopy Options If any parameter needs to be edited use the following steps 1 Move to the Main screen and click the minimize button on the top right corner of the screen 2 To enter the Config directory double click the ENTEGRA Command Prompt on the desktop and type CD Config 3 Type the following to backup the HCdefaults win32 file copy HCdefaults win32 HCdefaults win32 org lt Enter gt 4 Type the following to open the HCdefaults win32 file using the notepad editor notepad HCdefaults win32 lt Enter gt 5 Type the following to go to the line containing the xxxxx parameter lt Ctril gt lt F gt xxxxx lt Enter gt The cursor will be set on the first character of the desired line e g ISGmfhd white_set 0 6 Press the key until the cursor is over the first character to be changed overtype this character 7 Save the changes and quit the notepad editor by selecting File gt Save File Exit 8 Type the following to copy the modified HCdefaults win32 file in the config directory copy HCdefaults win32 HCdefaults win32 bak lt Enter gt 9 Go back to the eNTEGRA Main Screen click the X button and in the System Shutdown dialog click the Full button 10 Restart the eNTEGRA The AE Title for these printers will most likely need to be c
118. Table 5 7 lists the software contents Table 5 7 Software Contents Operating System Function Specification Microsoft NT 4 0 Application eNTEGRA Processing amp Review Networking DICOM Stations TCP IP over Ethernet Remote Database IEE802 3 Network Printing Starcam Systems OSI package SP Systems eNTEGRA P amp R Service Manual Direction 2263784 100 5 11 Rev 5 June 17 2001 System Description Software Description 5 2 2 License Keys There are two main software license keys for the basic eNTEGRA system These are referred to as the Node Locked Licenses e iap base Main server license e pr 3d Reconstruction server license These license keys control access to the proprietary servers in the eENTEGRA software The license keys restrict the use of the eNTEGRA software to a specific workstation This is done by using the license in conjunction with an activator plugged into the parallel port In addition to the Node Locked licenses there are nine option license keys assigned per Activator ID e CEqual or CEqual Light e ECToolbox or ECToolbox Upgrade e QGS Quantitative Gated SPECT e QPS Quantitative Perfusion SPECT e T1201 Database Upgrade e QuantEM e Aladdin Compose and Edit e PefrSPECTive 3D Volume Rendering e Remote Connectivity e CT MR DICOM Storage e Interactive Reconstruction eNTEGRA P amp R Service
119. Type Interface Laser Imation 3M P831 SCSI 2 via DASM LCAM Section 3 10 2 Cameras M952 959XL 969HQ and DryView Kodak XLP100 1120 SCSI 2 via DASM LCAM Section 3 10 3 and 2180 Dupont Linx Image Q SCSI 2 via DASM LCAM Section 3 10 4 Fuji SCSI 2 via DASM LCAM Section 3 10 5 Konica Li10A amp Li20 SCSI 2 via DASM LCAM Section 3 10 6 Polaroid Helios Network TCP IP Section 3 10 7 Color Codonics NP1600M Network TCP IP Section 3 10 8 Printers PostScript PostScript Compatible Network TCP IP or Section 3 10 9 Printers Printer Parallel Port DICOM DICOM Compatible Network TCP IP Section 3 10 10 Printers All hardcopy devices interfaced via the SCSI port or network must be configured in eNTEGRA using the Config utility eNTEGRA P amp R Service Manual Direction 2263784 100 3 33 Rev 5 June 17 2001 Installation Hardcopy Options 3 10 2 Imation 3M Lasercameras Configuration 3 10 2 1 Overview Note This section provides details on how to connect the Imation 3M family of Lasercameras to the eNTEGRA system using the 952 interface and how to configure both the eNTEGRA and Lasercamera to produce good quality films This includes the 952 959 969 and Dry View Lasercameras The eNTEGRA hardcopy server sends commands and high resolution digital image data to DASM LCAM over the SCSI 2 bus using the Analogic DASM SCSI command set The DASM LCAM converts these commands in
120. age and click on Finish to start the driver installation 11 When driver installation has been completed click on Start in the Task Bar select Setting Control Panel 12 Double click on Network and go to the Service tab eNTEGRA P amp R Service Manual 3 78 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options 13 Check that Microsoft TCP IP Printing service is present If so skip to Step 22 Otherwise proceed to Step 14 14 Insert the Window NT CD into the CD drive 15 Click on Start in the Task Bar and select Setting gt Control Panel 16 Double click on Network and go to the Service tab 17 Click Add 18 Select Microsoft TCP IP Printing and click OK 19 Set the path as E i386 and click Continue to begin installation E stands for the CD drive 20 Click Close 21 Click Yes to restart the system 22 Click on Start in the Task Bar and select Setting Printers 23 Highlight the PostScript printer press the right mouse button and select the Properties entry 24 Click on the Ports tab 25 Click Add Port 26 Highlight LPR Port and click on New Port 27 Type the printer IP address recorded in the pre installation checklist as the Server Address 28 Type PS as the Printer Name and click OK 29 Click Close 30 Click OK eNTEGRA P amp R Service Manual 3 79 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardco
121. al Parts Documentation 9 3 Documentation Table 9 3 eNTEGRA Documentation English PN OPT000396 Description ELGEMS SEMS Part Number Part Number eNTEGRA Operator s Manual MANO000388 2266250 100 eNTEGRA Service Manual this manual MAN000377 2263784 100 eNTEGRA Site Preparation Manual MANO0038 1 2264704 100 eNTEGRA CIS MANO00529 2291227 100 The English on line help files are provided on the eNTEGRA application SW CD Table 9 4 eNTEGRA Documentation French PN OPT000391 Description ELGEMS Part Number GEMS Part Number eNTEGRA Operator s Manual MANO00501 2266250 101 eNTEGRA CIS MANO00509 2267854 101 eNTEGRA On line Help CD MANO000507 Table 9 5 eNTEGRA Documentation Spanish PN OPT000392 Description ELGEMS GEMS Part Number Part Number eNTEGRA Operator s Manual MAN000502 2266250 106 eNTEGRA CIS MAN000510 2267854 106 eNTEGRA On line Help CD MANO000507 Table 9 6 eNTEGRA Documentation Portuguese PN OPT000395 Description ELGEMS Part Number GEMS Part Number eNTEGRA Operator s Manual MANO00505 2266250 127 eNTEGRA CIS MANO00513 2267854 127 eNTEGRA On line Help CD MANO000507 eNTEGRA P amp R Service Manual 9 3 Direction 2263784 100 Rev 5 June 17 2001 Renewal Parts Documentation Table 9 7 eNTEGRA Documentation German PN OPT000393 Description ELGEMS Part Numb
122. amera has been added to the eNTEGRA Config utility refer to Section 3 6 and Section 3 8 for details The Device Type should be set to ISG3m in the Printers tab of the Config utility Install and connect the host and image data runs between the Lasercamera s input module and the DASM LCAM This is typically done by the Kodak service engineer Refer to Section 3 10 3 3 Have the Kodak service engineer configure the Lasercamera s input module for communication with the DASM LCAM Refer to Section 3 10 3 3 Edit the HCdefaults win32 to add the Kodak model type and edit the contrast settings Refer to Section 3 10 3 3 Power up the systems in the following order to assure proper synchronization Lasercamera DASM LCAM and then the eNTEGRA Log into eNTEGRA select the Formatter Static image from the Default Patient Calibration study and click the New icon located on the Patient Selector Control Bar Click the Camera tool in the Display Screen Click the Down Arrow in the Film dialog select the Kodak Lasercamera and click Submit If a No image is printed refer to Section 8 2 5 for details on troubleshoot ing b An image is printed analyze the image and determine if additional adjustments are required If a The boarder needs to be changed the HCdefaults win32 file will need to be edited on the eNTEGRA and the servers to be restarted Refer to Section 3 10 3 4 b Any other image quality adjustments need to be made
123. amp R systems is carried out via DICOM eNTEGRA P amp R Service Manual Direction 2263784 100 Rev 5 June 17 2001 System Description Software Description In order for the eNTEGRA P amp R to send data via DICOM the AE parameters for that system must be configured on the sending eNTEGRA P amp R Table 5 10 provides a list and description of the required AE parameters Table 5 10 AE Parameters AE PARAMETER System Name DESCRIPTION This is the name that identifies the system at the user level aui Typically the host name is used but a more descriptive name can be used The system name can contain a maximum of 12 characters using only a z A Z 0 9 or _ AE Title This defines the system at the DICOM server level Check the system s DICOM Conformance statement for this parameter IP Address This is the IP Address of the remote system Port This is the TCP listening port of the system It is used by the DICOM server to establish the TCP connection Check the system s DICOM Conformance statement for this parameter To enable the local eNTEGRA system to query and fetch from a remote system via DICOM the above AE parameters for the local system must be configured on the remote system DICOM configuration on the local eNTEGRA P amp R activated using the Config button on the Patient Selector eNTEGRA P amp R Service Manual Direction 2263784 100 5 18 Rev 5 June 17 2
124. ant database ii Click on the Retrieve button 8 Retrieve the User Protocols from the optical cartridge as follows a b Select the database you to which you want to restore the User Protocols Locate the Aladdin Protocols study within the optical directory and select it Click the Retrieve button to copy the Aladdin Protocols study to the selected database Activate the Aladdin Archive application from within the Housekeeping category eNTEGRA P amp R Service Manual Direction 2263784 100 3 Rev 5 June 17 2001 Upgrading From GENIE P amp R e For each user protocol to be restored i Click on the Load a Script button ii From the opened list select the database to which the user protocols will be restored iii From the opened list select the protocol you wish to load iv Click on the OK button The message Loading appears in the upper left corner of the tab card The message Load Completed appears in the upper left corner of the tab card The database from which the protocol was loaded for example local and the protocol name for example CARDREVIEW are listed on the processing screen The protocol name is added to the Protocol Open list within the Aladdin Card If a protocol of the same name already exists an appropriate warning appears f When all the User Protocols have been restored install each user protocol under the relevant category as follows i Cl
125. asic Procedure This section provides the basic procedure to interface and configure a DuPont Lasercamera with eNTEGRA 1 Verify that the DASM LCAM is connected configured properly and the Lasercamera has been added to the eNTEGRA Config utility refer to Section 3 6 and Section 3 8 for details The Device Type should be set to SGdupont_3m Install and connect the host and image data runs between the SID and the DASM LCAM This should be done by the Sterling service engineer Refer to Section 3 10 4 3 Configure the SID for communication with the DASM LCAM This should be done by the Sterling service engineer Refer to Section 3 10 4 3 Power up the systems in the following order to assure proper synchronization SID DASM LCAM and then the eNTEGRA Log into eNTEGRA select the Formatter Static image from the Default Patient Calibration study and click the New icon located on the Patient Selector Control Bar Click the Camera tool in the Display Screen Click the Down Arrow in the Film dialog select the DuPont Lasercamera and click Submit If a No image is printed refer to Section 8 2 5 for details on troubleshoot ing b An image is printed analyze the image and determine if additional adjustments are required Any adjustments for image quality will be made via the SID by the Sterling Service Engineer Refer to Section 3 10 4 4 Repeat steps 5 through 7 until optimal film quality is achieved eNTEGRA P a
126. atches are loaded If not contact Codonics service eNTEGRA P amp R Service Manual Direction 2263784 100 8 5 Rev 5 June 17 2001 Troubleshooting and Repair Troubleshooting 8 2 6 Codonics Status Check 1 Click on the minimize button on the Main Screen Header to view the system s Desktop 2 Click the Start button on the Task Bar at the bottom of the screen and select Programs Command Prompt 3 Type telnet codonics lt Enter gt The telnet session will display any communication between the eNTEGRA and the Codonics The system responds with Connected to codonics Escape character is UNIX r System V Release 4 0 np1600 login 4 Type root lt Enter gt The system responds with Last login Wed Apr 2 12 11 25 from 3 28 127 70 Sun Microsystems Inc SunOS 5 3 Generic September 1993 5 To to look at the configuration parameters type at the UNIX prompt stat eNTEGRA hostname The system responds with the following information Status Ready Date 16 Apr 1997 09 04 Media A Size Paper Printer ID 8033 d354 Ribbon CMY E net Addr 08 00 20 1f 65 55 Mem Config 16MB RAM Queue 0 jobs in image queue Hard Drive 270MB Quantum 0 jobs in image queue SW Version 1 3 2 Caption none Keys POSTSCRIPT Key 00QIEKQZFO Permanent ISG_1 Key 40QRC3BRIUPermanent Defaults Printer root User eNTEGRA TCR 0 TCR NOT SET Gamma 1 00 Gamma 1 5 Antialias None Antialias NOT SET Rotat
127. atement 4 Save the changes and quit the notepad editor by selecting File gt Save File Exit 5 Go back to the eNTEGRA Main Screen click the X button and in the System Shutdown dialog click the Full button 6 Restart the eENTEGRA eNTEGRA P amp R Service Manual 3 87 Direction 2263784 100 Rev 5 June 17 2001 Installation InSite Entitlement 3 11 InSite Entitlement 1 Double click the iLing Shell icon residing on the desktop 2 In the opened window type configlink p v lt Enter gt If the following error message is displayed ignore it C insite insiteINFO does not exist or is empty 3 In the opened window type iipadmin config lt Enter gt Note should a message window titled NT Type appear click OK to continue 4 Inthe opened InSite Interactive Platform Configuration window click ACCEPT 3 times 5 Click on the ProDiags tab all other tabs will automatically come forward after necessary confirmation and set the parameters as follows a On the ProDiags tab click DEFAULT The system will advance to the Device Connection Tab automatically b On the Device Connection tab select the options applicable to the installed modem from the following pull down lists e Dial Out Prefix what the customer will have to dial to place a call e Modem Type select the currently installed modem from the list e CPU Serial Port Name select the Port the modem is installed on e Dialling M
128. ation PC Installation 3 4 PC Installation 3 4 1 Installation Overview Note Table 3 5 outlines the steps for installing the eNTEGRA PC hardware Refer to the PC User s Guide for details Table 3 5 Installation Overview Time Steps Min Reference Unpack PC components 5 PC User s Guide Unpack and Position In above Refer to Site Plan diagram Processor Unit per customer s specifications Unpack Monitor 5 Keyboard and Mouse Position Monitor In above Refer to Site Plan diagram Keyboard and Mouse per customer s specifications Connect PC cables 5 PC User s Guide Figure 5 1 Connect appropriate 5 Section 3 4 2 Network Transceiver and Figure 5 1 or Drop Cable Plug in the Activator In above Section 3 4 3 Total 20 A desk is not provided as part of the standard system Arrangements should have been made during site preparation eNTEGRA P amp R Service Manual Direction 2263784 100 3 8 Rev 5 June 17 2001 Installation PC Installation 3 4 2 Network Connection The eNTEGRA P amp R PC includes a 10 100 Base T IEEE 802 3 Ethernet card This card provides a RJ45 interface to connect into either a 100 Base T or 10 Base T IEEE802 3 HUB via a category 5 unshielded twisted pair CAT 5 cable The HUB and CAT 5 drop cable should have been installed as part of the site preparation process To interface the PC to the HUB e Connect one end of the categ
129. ation over the SCSI bus and interfaces them to the laser camera RS 485 digital image serial interface and RS 422 serial communication interface In addition the LCAM includes a 12 bit in and 8 bit out Look Up Table Byte Swap Function and text and outline annotation capabilities Refer to Figure 5 1 Important The DASM LCAM can only be used with Laser Cameras that support the Imation 952 digital interface protocol SCSI Interface Image Data Laser RS485 i 37 Workstation DRAM Camera O Laser with SCSI 1 8 MB Camera Interface Laser 25 Camera prn m Processor Communication Controller Data R8422 Figure 5 4 LCAM Block Diagram The LCAM contains 1 Mbyte of on board Data Memory standard which appears to the workstation as a SCSI disk drive responding the SCSI Common Command Set Data Memory is used for image storage as well as for host command and status handshaking The workstation application makes command status and image transfers by accessing LCAM Data Memory through the SCSI bus eNTEGRA P amp R Service Manual 5 9 Rev 5 Direction 2263784 100 June 17 2001 System Description Software Description 5 2 Software Description Software Description includes the following 5 2 1 Software Structure Figure 5 5 provides a visual view of how the eNTEGRA software is structured Graphica
130. ble click on XPert Tools icon in the desktop b Double click on User BackUp icon and follow the screen instructions Note You will be prompted for blank diskettes to save user data 3 Review and record update the information from the following XPert utilities in the System Information tables refer to chapter 2 of XPert XPertView Software Installation e LAN Station List e WAN Station List e Printer Selection and Setup e TCP IP Configuration 4 Perform Low Level Format as per Section A 3 below Install eNTEGRA software starting from Software Load From Cold For Dell OptiPlex GX200 on page 6 2 6 Configure the eNTEGRA Environment based on the data you collected in step 3 starting from Site Configuration on page 3 14 Important Keep the User Backup diskette for reference eNTEGRA P amp R Service Manual 1 Rev 5 Direction 2263784 100 June 17 2001 Upgrading From GENIE P amp R A 2 Upgrading From GENIE P amp R l Before beginning the upgrade you must ensure that all the studies from the local database were transferred to a remote station or an archiving device If you have Review Templates which you want to transfer to eNTEGRA back them up to the optical disk as follows a b Click the Archive tab In the Archive panel click the Job Options button In the opened Archive Retrieve dialog i Check the Archive system data checkbox ii Click OK Archive any study to the optical cartridge
131. camera Connection This section provides details on how to interface the Fuji Lasercamera to the eNTEGRA system via the DASM LCAM a Interface Wiring Figure 3 13 and Table 3 22 detail the interface between the eNTEGRA and the Fuji Lasercameras using the DASM LCAM 120VAC DASM LCAM Lasercamera Fuji Interface Multiformatter Lasercamera Figure 3 13 eNTEGRA to Fuji Lasercamera Interconnection via the DASM LCAM Table 3 22 DASM LCAM to Fuji Lasercamera Cable Summary ca Description Part Source Length Reference 1 SCSI 1 to SCSI 2 Cable 46 269566P104 1m 2 37 Pin LCAM Image Data Fuji Fuji Service Cable RS485 Engineer 3 25 Pin Male to 37 Pin 46 296980G1 30 cm GEMS or Fuji Female RS422 Stub Cable 4 37 Pin RS422 Host Fuji Fuji Communication Cable Service Engineer 5 Lasercamera Interface Note Refer to Section 5 1 3 1 for pin out details on the DASM LCAM eNTEGRA P amp R Service Manual 3 60 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options 3 10 5 4 Interface Configuration The Fuji Multiformatter must be configured to communicate with the eNTEGRA Table 3 23 summarizes the configuration parameters that need to be set on the Fuji Multiformatter for the DASM LCAM interface The Fuji Service Engineer will be responsible for configuring and interfacing the Multiformatter Table 3 23 DASM LCAM to Fuji Mu
132. chive 10 Highlight this study on the local archive and click the Delete button In the Patient Data Delete dialog click Delete Selection to confirm eNTEGRA P amp R Service Manual 4 7 Rev 5 Direction 2263784 100 June 17 2001 Functional Checks Checking the OSI Connectivity 4 8 Checking the OSI Connectivity 1 Click on the Network Tab from the Einstein Main screen 2 Click on the Search Fetch tab 3 4 Click on the Search Fetch Template button In the Search Template check the relevant Search Fetch type and the remote station name Click the Search button Verify that the remote station s studies are displayed in the Search Fetch tab 4 9 Modem Connectivity Check va Double click on My Computer icon on the desktop 1 2 Double click the Dial up Networking icon 3 4 Click Dial In the Connect to Server_Name dialog type in the user name and password for accessing this remote server and click OK The Dialing remote_number message appears 6 When the connection is established a pop up notifying Verifying user name and password appears If the connection is successful a Telephone icon appears at the right corner of the Task Bar To end the connection double click the Telephone icon and in the opened dialog click Hangup eNTEGRA P amp R Service Manual 4 8 Rev 5 Direction 2263784 100 June 17 2001 Functional Checks InSite Operation Check
133. ck Yes 41 When prompted press lt Alt gt lt Ctrl gt lt Del gt and login as follows User Name Administrator Password elgems 42 Click OK eNTEGRA P amp R Service Manual 6 8 Rev 5 Direction 2263784 100 June 17 2001 Software Installation Software Load From Cold For Dell OptiPlex GX200 43 Define the users as follows 44 45 46 m j Click the Start button on the Task Bar at the bottom of the screen and select Programs Administrative Tools User Manager In the User Manager window click on User in the Menu Bar and select the New User entry Uncheck User Must Change Password at Next Logon Click the checkbox next to Password Never Expires Click the Groups button In the Group Memberships window click Administrators if not already highlighted and then click the lt Add button The Admin istrators entry moves from the Not member of list to the Member of list Click OK In the New User window enter Username entegra Password entegra Confirm Password entegra Click OK again Close the User Manager window Click the Start button on the Task Bar at the bottom of the screen and select Shutdown the system In the Shut Down window select Close all programs and log as a different user then click Yes When prompted press lt Alt gt lt Ctrl gt lt Del gt and login into the system with Username entegra Password entegra
134. e Auto Rotate NOT SET Scale Bilinear Scale NOT SET MCM 1 MCM 12 6 Verify that a The JSG_1 key is listed under keys b The Defaults for User ENTEGRA are set to the values configured during installation Section 3 10 8 5 7 To quit the telnet session type exit lt Enter gt The telnet session will display any communication between the eNTEGRA and the Codonics It can also be used to look at the configuration parameters using the stat utility or verify which patches have been loaded For complete details on using the telnet session for troubleshooting refer to the Codonics Users Manual eNTEGRA P amp R Service Manual 8 6 Rev 5 Direction 2263784 100 June 17 2001 Troubleshooting and Repair Troubleshooting 8 2 6 1 Checking Status The stat utility provides basic configuration information for the Codonics This includes the printers software revision license keys activated and default printer settings To use 1 Open a telnet session 2 At the UNIX prompt type 8 2 7 Releasing the System When it Gets Stuck When the system is stuck 1 Press lt Alt gt lt Ctrl gt lt Del gt to display the Windows NT Security window 2 Click the Task Manager button Using the Down Arrow key move the cursor to highlight the eNTEGRA exe file and click the End Task button 4 Restart eNTEGRA 8 2 8 Restoring Pervious Configuration When problems are encountered following any system configuration change
135. e Manual 3 36 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options 3 10 2 4 Lasercamera Connection This section provides details on how to interface the Imation Lasercameras to the eNTEGRA system via the DASM LCAM a Interface Wiring Figure 3 4 and Table 3 14 detail the interface between the eNTEGRA and the Imation Lasercameras using the DASM LCAM H 3 10 Meters Imation 3M J vasmicam_ oar riser optic _ Laser Camera Q BREE FIBER OPTIC 120 VAC Input Module Figure 3 4 Note eNTEGRA to Imation Lasercamera Interconnection via the DASM LCAM Table 3 14 DASM LCAM to Imation Lasercamera Cable Cable Description Part Source Length Reference 1 Peripheral Tower SCSI 46 325201P5 1m Section 5 1 3 Cable 2 37 pin LCAM Image Imation 3 10 m Reference 3M Data Cable RS485 Service Manual 3 25 pin Male to 37 Pin 46 296980G1 30 cm Female RS422 Stub Cable 4 3M Keypad Cable 37 Imation 3 10 m Pin RS422 5 Fiber Optic Line Tx Imation 30 100 m Rx Image Data 6 Fiber Optic Line Tx Imation 30 100 m Rx Host Communication The Input Modules available on the DryView Lasercameras provide direct 37 pin interface connections for both host and image data The 952 Lasercameras with MMU use two 37 pin interface connections for both host and image data
136. e Select 24 DGMODESEL Mode Select 6 DGCLK Strobe Clock 25 DGCLK Strobe Clock 7 DGPAR Parity 26 DGPAR Parity 8 DATA7 27 DATA7 9 DATAG 28 DATAG 10 DATAS 29 DATAS 11 DATA4 30 DATA4 12 DATAS 31 DATAS 13 DATA2 32 DATA2 14 DATA1 33 DATA1 15 DATAO 34 DATAO 16 19 No connection 35 37 No connection eNTEGRA P amp R Service Manual Direction 2263784 100 5 5 Rev 5 June 17 2001 System Description Hardware Description Table 5 5 Pin Assignment of the 25 pin to 37 pin Communication Stub Cable 25 Pin 37 Pin Connector Connector Signal Pin Pin 1 6 1 4 6 No connection 7 7 Signal Ground 8 20 RX Serial input to DASM diff 9 21 TX Serial output from DASM diff 10 12 8 12 No connection 13 13 Signal Ground 14 20 14 19 No connection 21 2 RX Serial input to DASM diff 22 3 TX Serial output from DASM diff 23 25 22 37 No connection 5 1 3 2 SCSI Address Assignment Table 5 6 lists the assigned SCSI Addresses for the eNTEGRA Workstation Table 5 6 SCSI IDs SCSI Bus Device SCSI ID Ultra 2 Wide Internal Hard Drive System 0 Ultra Narrow Optical Disk 1 SCSI Adapter DASM LCAM or MFHD or MF96 4 eNTEGRA P amp R Service Manual 5 6 Rev 5 Direction 2263784 100 June 17 2001 System Descrip
137. e XLP100 1120 2180 Lasercameras The eNTEGRA hardcopy server sends commands and high resolution digital image data to DASM LCAM over the SCSI 2 bus using the Analogic DASM SCSI command set The DASM LCAM converts these commands into the 952 commands and a digital image Due to image quality issues the DASM VDB interface is no longer being offered The 952 commands host control are sent from the DASM LCAM s 25 pin female RS422 port to the 15 pin RS422 host communication port port 1 on the Lasercamera s input module A MOD42 cable will be required to convert from the 25 pin connection on the DASM unit to the 15 pin connector on the input module The DASM LCAM sends the high resolution digital image data over a 37 pin 8 bit parallel RS485 interface to the Lasercamera s input module Section 3 10 3 2 provides the basic procedure for interfacing configuring the Kodak Lasercameras to ENTEGRA Section 3 10 3 3 provides details on interfacing the Kodak lasercameras to the eNTEGRA Section 3 10 3 4 provides details on configuring the eNTEGRA and the Lasercamera for optimal image quality eNTEGRA P amp R Service Manual 3 47 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options 3 10 3 2 Basic Procedure This section provides the basic procedure to interface and configure a Kodak Lasercamera with eNTEGRA 1 Verify that the DASM LCAM is connected configured properly and the Laserc
138. e imn Trie onan 3 2 3 Product Locator CatS ssiiiciiiasiintiiirinrnninriiatiras eie Isolation Transformer Tie allationiccsivsessissreenasissersereseiaans Fal st Frocedute errar eee eNTEGRA P amp R Service Manual Direction 2263784 100 Rev 5 6 17 01 Table Of Contents 3 4 Pe eraa chin nle e enataweie 3 8 3 4 1 PY ores ine cece creeds eeaeeoes 3 8 3 4 2 TAT E oone ea N 3 9 3 4 3 PS 30 Wie Aiva aa ee ee ee 3 10 3 5 Comment Peripheral TOW inanasan 3 10 Jal Trod oi E 3 10 e ee Tiree Gio Procediti spsiccccassinasorcsincrannsinadensnanmsninecsuneromnnadannunaniasa 3 10 3 6 DL oh ee ee eee 3 11 3 6 1 O O a inc ened eee ese 3 11 3 6 2 Tostal on Pree n a oeiNnEnY Nes HempRrse esr eeneeery 3 11 a Tutal System POWE r Ues 3 12 Atal Procedi Ceon Ta 3 12 ce Dae Te SEs N 3 12 3 8 SLAR I IN E E T A T E E A a ae 3 14 3 8 1 SE L Sa e E E E E E E E E E ru Sree Te 3 14 3 8 2 Paci cB cl cg 0 ne serie a tee teenie ye it enonr SMerine nnn meer Ar 3 14 2a Procedure VBE isisisacnisinieoninrintdarinnariousincaneniaied aa n 3 15 3 8 4 Syse eh Procede suan r 3 16 3 8 4 1 Change nsitmtion ID vicina 3 16 3 8 4 2 Change Default Computer NAME sssini 3 16 3 8 4 3 Updating tbe Rerional Settings n erasinn a a 3 17 3 8 4 4 Updating Seting the IF As es eros 3 17 3 8 4 5 StarLink and ApexNet Configuration applicable only if the OSI option is installed eee eeeeeereees 3 18 3 8 4 6 Re Ee iv ccicsnc ep rica RivantarivcaSeanapaaiaionyiediaaduaii 3 19 3 8 4 7
139. e in the Command Line of a remote SP based system ETCONFIG and press lt Enter gt This results with the following display LOCAL COMMUNICATION ADDRESS 00AA000XXXXX LOCAL WRITE PROTECT Y N N STATION ID TYPE COMMUNICATION ADDRESS STATION LABEL NO A 00AA0004460B SP1 N1 A 00AA00044802 HELIX N2 A 00AA00034BBC CardiaL Where e The LOCAL COMMUNICATION ADDRESS is the unique Ethernet Address of the system stored in the system s Ethernet Controller Board which consists of a fixed prefix 00AA000 and five variable hexadecimal digits indicated by XXXXX e TYPE A refers to an APEX SP system TYPE G refers to an APEX 400 system e The STATION LABEL is the station s name eNTEGRA P amp R Service Manual 3 32 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options 3 10 Hardcopy Options 3 10 1 Note Note Overview The eNTEGRA P amp R Hardcopy server provides a high resolution digital multiformatted n on 1 image for use on Formatters Lasercameras and Color Printers via the e SCSI 2 port e Network port eNTEGRA will only support one SCSI 2 print device Table 3 13 summarizes the hardcopy devices that are compatible with eNTEGRA P amp R the type of interface used and the sections that contain the installation configuration information for each device Table 3 13 Hardcopy Device Interface Matrix Hardcopy Device Name ENTEGRA FSH Reference
140. ed with its own rating plate and tracked by the Product Locator This process allows for software only field modifications and preserves traceability of software revisions and options at each site 3 14 1 2 Procedure for Units with an Isolation Transformer For units with an Isolation Transformer attach the rating plate for the eNTEGRA Base Application Software Set Software Option to the side of the isolation transformer See Locating Rating Plate Figure 3 21 eNTEGRA Rating Plate Location Figure 3 21 Locating Rating Plate 3 14 1 3 Procedure for Units Without an Isolation Transformer For units without an Isolation transformer attach the rating plate for the Basic eNTEGRA Application Software Set to the eNTEGRA CD ROM software jewel case eNTEGRA P amp R Service Manual 3 91 Rev 5 Direction 2263784 100 June 17 2001 Installation Completion 3 14 2 Cabling Tidy up all cables paying particular attention to the rear of the Workstation particularly the rear interconnection panel External cabling should also receive attention and be neatly finished using cable ties as necessary 3 14 3 Completing the Paperwork Important Complete all Product Locator Cards supplied with the system and options Please complete the Installation Audit Form supplied with the unit Return together with Installation Card to Locator File W 523 General Electric Medical Systems P O Box 414 Milwaukee Wisconsin 5320
141. elect the Properties entry 2 In the opened Task Bar Properties window uncheck the Always on top option 3 Click OK to close the Task Bar Properties window 6 2 10 4 Setting the View Options 1 Double click My Computer icon 2 Inthe opened My Computer window click the View option in the Menu Bar and select the Options entry 3 In the Options window click the Folder tab 4 Click the radio button next to Browse folder by using a single window that changes as you open each folder then click the Apply button 5 Click the View tab in the Options window 6 Click the radio button next to Show all files option 7 Uncheck the option Hide file extensions for known file types click OK to close the Options window 8 Close My Computer window eNTEGRA P amp R Service Manual 6 14 Rev 5 Direction 2263784 100 June 17 2001 Software Installation Software Load From Cold For Dell OptiPlex GX200 6 2 11 Installing Internet Explorer 5 1 For the English version skip to Step 2 below For other languages replace the eNTEGRA application CD with the eNTEGRA Accessories Software CD 2 Double click on My Computer icon located on the desktop 3 Double click the D drive CD ROM Drive For the English version skip to Step 5 below For other languages double click the applicable language Double click the IE5 directory Double click install bat When installation has been completed the system will reb
142. er GEMS Part Number eNTEGRA Operator s Manual MANO000503 2266250 108 eNTEGRA CIS MANO00511 2267854 108 eNTEGRA On line Help CD MANO000508 Table 9 8 eNTEGRA Documentation Italian PN OPT000396 Description ELGEMS Part Number GEMS Part Number eNTEGRA Operator s Manual MAN000504 2266250 111 eNTEGRA CIS MAN000512 2267854 111 eNTEGRA On line Help CD MAN000508 Table 9 9 eNTEGRA Documentation Swedish PN OPT000394 Description ELGEMS GEMS Part Number Part Number eNTEGRA Operator s Manual MAN000506 2266250 142 eNTEGRA CIS MAN000514 2267854 142 eNTEGRA On line Help CD MANO00508 Table 9 10 Vendor Supplied Manuals Description PC User Manual Monitor User Guide Modem User Manual eNTEGRA P amp R Service Manual Direction 2263784 100 9 4 Rev 5 June 17 2001 Appendix A Upgrading to eNTEGRA A 1 Upgrading From XPert Systems A CAUTION Leave the XPert Activator plugged into the computer Its ID was included in the FDO and the eNTEGRA software used for this upgrade matches this specific activator ID Removing or replacing the activator will disable the upgrade 1 Before beginning the upgrade procedure ensure that all the studies from the local database were transferred to a remote station or an archiving device 2 Prepare User Backup diskette s as follows a Dou
143. er Supplied N A N A 12 Category 5 UTP Cable 2215028 4 1 2 m 6 6 ft DASM LCAM Connectors Pin Out This section provides the pin outs for the connectors and cables used to interface the eNTEGRA to a laser printer through the DASM LCAM The pin outs of the 25 pin Connector on the DASM LCAM Communication Cable RS 422 are listed in Table 5 3 The pin outs of the 37 pin Connector on the DASM LCAM Image Data Cable RS485 are listed in Table 5 4 The pin assignments of the 25 pin to 37 pin Communication Stub Cable are listed in Table 5 5 eNTEGRA P amp R Service Manual Direction 2263784 100 5 4 Rev 5 June 17 2001 System Description Hardware Description Table 5 3 Pin Outs of the DASM LCAM Communication RS 422 Cable 25 pin Connector Pin Signal 1 Case Ground 2 7 No connection 7 Signal Ground 8 RX Serial Input to DASM diff 9 TX Serial output from DASM diff 10 20 No connection 21 RX Serial Input to DASM diff 22 TX Serial output from DASM diff 23 25 No connection Table 5 4 Pin Outs of the DASM LCAM Image Data RS485 Cable 37 pin Connector Pin Signal Pin Signal 1 2 No connection 20 21 No connection 3 DGREP Transmit 22 DGREP Retransmit 4 DGDAREQ Data Request 23 DGDAREQ Data Request 5 DGMODESEL Mod
144. er each reboot Click OK and ignore the message 15 When asked to restart the computer remove the Windows NT CD and press the Restart button 16 When prompted press lt Alt gt lt Ctrl gt lt Del gt and login into the system with User Name Administrator Password elgems 17 Click lt OK gt 18 In the Welcome screen that is opened click Close eNTEGRA P amp R Service Manual 5 Rev 5 Direction 2263784 100 June 17 2001 Installing Windows NT Networking 19 20 21 22 23 24 2N 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 Insert the eNTEGRA Application CD into the CD ROM drive Double click My computer D drive CD ROM Drive gt Drivers gt Drivers exe Click OK Click right on the Network Neighborhood icon on the desktop Click on the Properties entry Click Yes to confirm that networking is to be installed Click Next Click on Select From List In the Select Network Adapter window click on Have Disk Type in the path C Drivers 3Com Click OK twice Click Next 4 times Remove the eNTEGRA CD and insert the Windows NT CD Wait for the Windows NT CD window to open and close it In the Windows NT Setup window type in the path E and click Continue Upon the message If there is a DHCP click NO In the opened Microsoft TCP IP Properties window click the IP Address tab and a Type in your IP addre
145. er in HCdefaults win32 is only used to set the image polarity Values from 1 15 and D produce a positive image polarity white on black Values from 16 30 produce a negative image polarity black on white Refer to the HCdefaults win32 Configuration in Section 3 10 2 5 for details on setting the Prn3m 952 fmt n contrast parameter e The film contrast is set on the Lasercamera s input module The Prn3m 952 density parameter in HCdefaults win32 is ignored The film density is set on the Lasercamera s input module To set contrast and density values on the Kodak a Wyse terminal is required Table 3 19 provides a summary of the key parameters to adjust for film quality Table 3 19 Kodak Lasercamera Image Quality Parameters Parameter Description Where Set Reference Contrast Specifies a contrast table to Lasercamera s Kodak Service use to produce the image input module via a Engineer Wyse terminal Density Specifies the density setting for the film Curve Defines the Gamma correction curve Boarder Specifies the boarder level Prn3m 952 bdr 0 Black Boarder 0 is dark and 255 is clear parameter inthe 255 Clear Boarder HCdefaults win32 See file Section 3 10 3 3 for info on editing the HCdefaults win32 file eNTEGRA P amp R Service Manual 3 53 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options 3 10 4 DuPont Lasercameras Configura
146. ers sent by the eNTEGRA are configured in the HCdefaults win32 file and can be edited using the Notepad In addition to the image quality parameters the HCdefaults win32 file also contains the settings for the printers AE Title and Port Table 3 35 defines the main DICOM parameters that can be edited in the HCdefaults win32 file Table 3 36 lists the default setting for each of the validated printers Table 3 35 DICOM Print Parameter Definition eNTEGRA P amp R DICOM Hardcopy Server Definition Parameter Parameter IP Address ip_address Host name assigned to printer s IP address on the Hosts Tab of the Config utility AE Title scp_ae_title DICOM SCP AE Title The printer s AE Title Port port The printer s TCP listening port Medium Type medium Hardcopy Medium PAPER CLEAR FILM BLUE FILM Film Destination destination Destination of Film MAGAZINE PROCESSOR Film Orientation lt fmt_num gt orientation LANDSCAPE PORTRAIT Film Size ID lt fmt_num gt size_id 8INX10IN 14INX17IN 10INX14IN 24CMX24CM 24CMX30CM Mag Type lt fmt_num gt magnification Magnification Type REPLICATE BILINEAR CUBIC NONE Max Density lt fmt_num gt max_density Max density Defined in printer documentation Min Density lt fmt_num gt min_density Min density Defined in printer documentation Border Density lt fmt_num gt boarder_density Density of Boarder Defined in printer documentation
147. es to take affect 10 Call the OLC to verify InSite functionality eNTEGRA P amp R Service Manual 3 89 Rev 5 Direction 2263784 100 June 17 2001 Installation Backup 3 12 Backup 1 Click the Configuration button at the left upper corner of the Main screen 2 In the opened User Preferences window click Advanced Configuration Click the Archive tab Click the Backup button In the Backup destination dialog click Backup Oy OT o S When prompted insert a formatted diskette labeled ENTEGRA Configuration Backup into the floppy drive and click OK 3 13 Commissioning Table 3 38 System Commissioning Procedure Time Steps Min Reference Check the Grounding on the 10 Isolation Transformer Perform the functional checks 35 Chapter 4 Review Customer Information Letter for current Release Notes Total 45 3 14 Completion Table 3 39 Completion Overview Steps Time Min Reference Mount Rating Plate s 5 Section 3 14 1 Clean Area 5 Section 3 14 2 Complete Product Locators 5 Section 3 14 3 Total 15 eNTEGRA P amp R Service Manual 3 90 Rev 5 Direction 2263784 100 June 17 2001 Installation Completion 3 14 1 Rating Plates 3 14 1 1 Description Each eNTEGRA workstation is delivered with all software and licenses loaded onto the workstation Since software can change independent of any hardware modification the software is serializ
148. est a predetermined IP address Click OK to return to the Network Configuration dialog Click OK to return to the Remote Access Setup dialog Click Continue to return to the Network dialog then click Close Wait for the Network Settings Change window and click Yes to restart the computer eNTEGRA P amp R Service Manual 3 22 Rev 5 Direction 2263784 100 June 17 2001 Installation Site Configuration 3 8 4 9 Modem Configuration Configure the modem to enable dialing to other stations through the Dial Up Networking facility 1 Click left on the Start icon on the Task Bar and select Programs gt Accessories Dial Up Networking 2 In the opened Location Information dialog Select your country region from the drop down list Type in your area code Type in the number required to access an outside line if any anoop Click the radio button next to the local phone system Tone dialing or Pulse dialing e Click Close 3 Ifthe system notifies you that the phone book is empty click OK to add an entry to the phone book and proceed to step 3 below Otherwise skip to Step 10 4 Inthe opened New Phonebook Wizard dialog type in the name of the server used to connect to the remote network and click Next 5 In the opened Server dialog click Next 6 In the opened Phone Number dialog type in the phone number of the remote dial up server 7 If there are alternate nu
149. ested replace the eNTEGRA Application CD with the eNTEGRA On line Help CD Otherwise skip to step 22 below Click Next Next and then Finish eNTEGRA P amp R Service Manual 16 Rev 5 Direction 2263784 100 June 17 2001
150. et the boarder Choices are clear or black clear PrnHelios seperator clear PrnHelios exposure This parameter sets the polarity of the image printed on the film negative Choices are negative or positive A CAUTION Only edit the parameter listed in Table 3 28 Changing other parameters in HCdefaults win32 may cause errors in the hardcopy server eNTEGRA P amp R Service Manual 3 69 Direction 2263784 100 Rev 5 June 17 2001 Installation Hardcopy Options defaults for HELIOS print device i Prn Helios ip_addr polaroid j Change clear to black for black borders j rnHelios margin clear EE separator clear 4 Edit to change Border PrnHelios timeout 120 PrnHelios queue lpHelios PrnHelios formats 1 2 4 6 9 PrnHelios curve 17 lt Edit to change Curve PrnHelios brightness _ lt Edit to change Brightness PrnHelios contrast L 4 Edit to change Constrast PrnHelios dmin 0 02 P Prneiios dmax 2 01 4 Edit to change Density PrnHelios orientation landscape I Change negative to positive for white on black imaging PrnHelios exposure negative Edit to change Image Polarity PrnHelios 1 desc up PrnHelios 1 orientation landscape PrnHelios 1 max_width 2068 PrnHelios 1 max_height 2068 PrnHelios 1 min_widt
151. fthe above message appears reinstall the iap base license as per Section 6 4 1 on page 6 27 eNTEGRA P amp R Service Manual 8 3 Rev 5 Direction 2263784 100 June 17 2001 Troubleshooting and Repair Troubleshooting 8 2 3 Post Installation Problems Symptom During Load From Warm LFW the following message appears An error occurred during the move of data process 115 Possible Cause One or more of the eNTEGRA Servers are still active Corrective Action Close all eNTEGRA Servers by clicking the Stop Servers icon on the desktop and restart LFW eNTEGRA environment does not open successfully Files on hard disk are corrupted Reload eNTEGRA application perform LFW 8 2 4 Communication Problems Table 8 1 Communication Problems Symptom After configuring the network settings the eNTEGRA application will not re open Possible Cause Wrong settings in the eNTEGRA Config utility Corrective Action 1 Double click the eNTEGRA Prompt icon on the desktop 2 Type Econf lt Enter gt The Econf will open Review it and correct the network settings No communication with configured stations Remote station failure or OFF 1 Double click the ENTEGRA Prompt icon on the desktop 2 Type ping Hostname lt Enter gt where Hostname refers to the hostname of the remote station 3 If the remote station does not replay it is not available
152. ge 3 78 eNTEGRA P amp R Service Manual 3 77 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options 3 10 9 2 1 Software Installation for a Printer Interfaced via the Parallel Port 1 Power down the eNTEGRA 2 Click on Start in the Task Bar select Setting Printers 3 In the opened Printers window double click on Add Printer 4 Click on Next 5 Check the box next to LPT1 and click on Next 6 Insert the printer manufacturer CD into the CD drive and click Have Disk 7 Click on Browse select the appropriate installation file on the CD and click on Open 8 Click OK 9 Select the printer model and click on Next three times 10 Check the radio button next to No to avoid printout of test page and click on Finish to start the driver installation 3 10 9 2 2 Software Installation for a Printer Interfaced via the Network Port 1 Power down the eNTEGRA 2 Click on Start in the Task Bar select Setting Printers 3 In the opened Printers window double click on Add Printer 4 Click on Next 5 Check the box next to LPT1 and click on Next the port will be changed later 6 Insert the printer manufacturer CD into the CD drive and click Have Disk 7 Click on Browse select the appropriate installation file on the CD and click on Open 8 Click OK 9 Select the printer model and click on Next three times 10 Check the radio button next to No to avoid printing of test p
153. gt Insert STARTUP floppy Enter L lt Enter gt When prompted remove STARTUP floppy and insert Starlink V3 Key floppy Enter L lt Enter gt Enter C lt Enter gt Remove Key floppy and enter E lt Enter gt to exit back to RMX Insert CV system floppy Enter AF AFDO lt Enter gt Enters r load csd lt Enter gt to update the Starlink files Enter shutdown lt Enter gt to shut system down Reboot the system to Starcam by pressing the following keys together lt Ctrl gt RIGHT lt Shift gt lt Q gt Enter ZSCF 7 lt Sendform gt to list software present Verify that the Starlink option is present and that the version is 3 05 Add the eNTEGRA workstation to the Starlink Configuration file via the NAST command Refer to Section 3 9 3 to get the eNTEGRA s Ethernet LAN address 3 9 6 Starlink Version 4 Upgrade for Starcam Build Standard 1 amp 2 1 2 Refer to the documentation shipped with the H2508JA catalog to upgrade Starlink software to Version 4 Add the eNTEGRA workstation to the Starlink Configuration file via the NAST command Refer to Section 3 9 3 to get the eNTEGRA s Ethernet LAN address eNTEGRA P amp R Service Manual 3 31 Rev 5 Direction 2263784 100 June 17 2001 Installation Remote LAN Configuration 3 9 7 Getting the Ethernet Address and names of SP Based Systems To get the Ethernet addresses types and names of all the SP based systems residing on the ApexNet typ
154. h 8 PrnHelios 1 min_height 8 PrnHelios 1 num L PrnHelios 2 desc 2 up PrnHelios 2 orientation landscape PrnHelios 2 max_width 1265 PrnHelios 2 max_height 1265 PrnHelios 2 min_width 8 PrnHelios 2 min_height 8 PrnHelios 2 num 2 PrnHelios 4 desc 4 up PrnHelios 4 orientation landscape PrnHelios 4 max_width 1023 PrnHelios 4 max_height 1023 PrnHelios 4 min_width 8 PrnHelios 4 min_height 8 PrnHelios 4 num 4 PrnHelios 6 desc 6 up PrnHelios 6 orientation landscape PrnHelios 6 max_width 836 PrnHelios 6 max_height 836 PrnHelios 6 min_width 8 PrnHelios 6 min_height 8 PrnHelios 6 num 6 PrnHelios 9 desc 9 up PrnHelios 9 orientation landscape PrnHelios 9 max_height 682 PrnHelios 9 max_width 682 PrnHelios 9 min_height 8 PrnHelios 9 min_width 8 PrnHelios 9 num 9 Figure 3 16 HCdefaults win32 Helios Settings eNTEGRA P amp R Service Manual Direction 2263784 100 3 70 Rev 5 June 17 2001 Installation Hardcopy Options 3 10 8 Codonics NP1600M Color Printer Installation Configuration 3 10 8 1 Overview Note This section provides details on how to connect the Codonics Color printer to the eNTEGRA system and how to configure both the eNTEGRA and the Codonics to produce good quality films The eNTEGRA hardcopy server sends commands and high resolution digital image data to the Codonics via the Nuclear Local Area Network LAN using the IP command over the
155. hanged to match what Note the printer s local service engineer has set To find a specific printers parameters search on the DCM field for that printer For example to find the parameters for the Imation8300 search for DCMI8300 eNTEGRA P amp R Service Manual 3 86 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options 3 10 10 5 Adding a New Printer To add a printer that is not currently defined 1 Add the new printer under the Printers tab in the Config utility as follows a For the Printer Name enter a descriptive name for the printer no Spaces b For the Device Type enter one of the defined DICOM device types Refer to Table 3 37 for which device type to use Table 3 37 Default Hardcopy Server Device Type for DICOM Printing Printer Type eNTEGRA P amp R Hardcopy Server Device Type Monochrome Printer 8x10 Film DCMI8300 Monochrome Printer 14x17 Film DCMI8700 Color Printer 8x10 Media DCMA2KCl c Enter the IP Address of the printer 2 Open the HCdefaults win32 file using the Notepad editor as explained in Section 3 10 10 4 above Go to the parameter for the device type defined in the step 1 3 Set the DICOM parameters per the printer s DICOM conformance statement At a minimum the AE Title and Port must match the printer s SCP definition The max and min height width may also need to be changed based on the printer s conformance st
156. height 1024 Prn3m 952 6 2 contrasts D D _ Edit to change Contrast 6x1 Prn3m 952 6 2 lines 1600 Prn3m 952 6 2 bdr lines 32 Prn3m 952 6 2 hmag 0 Prn3m 952 6 2 vmag 0 Prn3m 952 6 2 hmode 15 Prn3m 952 6 2 vmode 15 zone 3 Prn3m 952 6 3 frames 2 Prn3m 952 6 3 width 1024 Prn3m 952 6 3 height 1024 prn m 952 6 3 contrasts D D _ Edit to change Contrast 6x1 rn3m 952 6 3 lines T600 Prn3m 952 6 3 bdr lines 32 Prn3m 952 6 3 hmag 0 Prn3m 952 6 3 vmag 0 Prn3m 952 6 3 hmode 15 Prn3m 952 6 3 vmode 15 format 9 Prn3m 952 9 desc 9 on 1 3 frames on each of 3 zones Prn3m 952 9 zones 3 zone 1 Prn3m 952 9 1 frames 3 Prn3m 952 9 1 width 1024 Prn3m 952 9 1 height 1024 Prn3m 952 9 1 contrasts D D D k Edit to change Contrast 9x1 Prn3m 952 9 1 lines 1600 Prn3m 952 9 1 bdr lines 32 Prn3m 952 9 1 hmag 0 Prn3m 952 9 1 vmag 0 Prn3m 952 9 1 hmode LS Prn3m 952 9 1 vmode 15 zone 2 Prn3m 952 9 2 frames 3 Prn3m 952 9 2 width 1024 Prn3m 952 9 2 height 1024 Prnom 952 9 2 contrasts D D D lt Edit to change Contrast 9x1 Prn3m 952 9 2 lines 1600 Prn3m 952 9 2 bdr lines 32 Prn3m 952 9 2 hmag 0 Prn3m 952 9 2 vmag 0 Prn3m 952 9 2 hmode 15 Prn3m 952 9 2 vmode 15 zone 3 Prn3m 952 9 3 frames 3 Prn3m 952 9 3 width 1024 Prn3m 952 9 3 height 1024 Prn3m 952 9 3 contrasts D D D Edit to change Contrast 9x1 Prn3m 952 9 3 lines 1600 Prn3m 952 9 3 bdr lines 32
157. here are no RAG click Yes to invoke Modem Installer In the opened Install New Modem dialog check the Don t detect my modem and click Next For systems with a modem installed select the modem manufacturer and model from the scrollable list and click Have Disk For systems with no modem installed select Standard type click Next select COM2 and click Next OK Continue If required insert the manufacturer s installation diskette into the floppy drive browse to the appropriate directory using the Browse button then click OK The modem drivers are copied to the hard disk Click the Properties button and enter the modem properties Remove the Windows NT CD from the drive Close the Network Properties window and click Yes to restart the system Proceed to Installing the FTP Service on page C 14 eNTEGRA P amp R Service Manual 13 Rev 5 Direction 2263784 100 June 17 2001 Installing the FTP Service C 11 Installing the FTP Service Insert the Windows NT CD into the CD drive Right click the Network Neighborhood icon on the desktop and select Properties to display the Network dialog Click the Service tab and click the Add button From the opened Select Network Service list select Microsoft Peer Web Server and click OK In the Installed from input field enter D i386 where D is your CD drive and click OK On the opened Microsoft Peer Web Services Setup d
158. ialog click OK In the opened Options list deselect all options except FTP Service and Internet Service Manager then click OK 8 Click Yes to create the prompted directory 10 11 12 13 14 15 16 I7 18 19 In the FTP Publishing Directories input field type C Insite and click OK If required acknowledge by clicking Yes to create the Insite directory When the installation has been complete successfully click OK Click Close in the Network dialog Click Start on the task bar and select Programs Microsoft Peer Web Services Internet Service Manager Double click the Computer Name entry to open the FTP Service properties for entegra dialog On the Service tab uncheck Allow only anonymous connections and confirm by clicking Yes Click the Directories tab select the displayed entry click Edit Properties check click the Write property then click OK Click Add enter C in the Directory field enter C in the Alias field click the Write checkbox located at the bottom of the screen and click OK Click Add enter D in the Directory field enter D in the Alias field click the Write checkbox located at the bottom of the screen and click OK Click OK and close the Microsoft Internet Service Manager dialog Proceed to Formatting Drive D as NTFS on page C 15 eNTEGRA P amp R Service Manual 14 Rev 5 Direction 2263784 100 June 17 2001
159. ick the Aladdin icon located below the Patient Selector ii Pull down the File menu on the Aladdin card and open the relevant user protocol iii Pull down the File menu on the Aladdin card and select the Install entry iv In the opened Install dialog select the protocol name and the relevant category make sure that Publish is set to YES then click OK Important Keep the GENIE backup optical cartridge for reference eNTEGRA P amp R Service Manual 4 Rev 5 Direction 2263784 100 June 17 2001 Low level Format A 3 Low level Format Power up the system During the boot up sequence press lt F6 gt to enter the SCSI Select utility Move the highlight to SCSI Disk Utilities and press lt Enter gt Highlight SCSI ID 0 SEAGATE and press lt Enter gt Highlight Format Disk and press lt Enter gt Move the highlight to Yes and press lt Enter gt to begin low level format Soh ON Ss hs ES Move the highlight to Yes and press lt Enter gt to confirm low level format eNTEGRA P amp R Service Manual 5 Rev 5 Direction 2263784 100 June 17 2001 Appendix B Software Installation on HP Kayak B 1 Overview This appendix provides detailed instructions for installing the basic software of the eNTEGRA system on the HP Kayak computer referred to as software load from cold For software load from warm and for installing the eNTEGRA software options and licences refer to the related sections in Chapter 6 S
160. indows NT Operating System on page 6 5 eNTEGRA P amp R Service Manual 6 4 Rev 5 Direction 2263784 100 June 17 2001 Software Installation Software Load From Cold For Dell OptiPlex GX200 6 2 4 Installing the Windows NT Operating System Turn ON the system and immediately insert the NT Installation CD When the words Windows NT Setup appear at the top of the screen press lt F6 gt repeatedly until the full Windows NT Setup screen appears and the white line at the bottom of the screen shows the option S Specify Additional Device Press lt S gt The SCSI Adapter list appears with Other selected 4 Press lt Enter gt and insert the diskette labeled SCSI Driver 294xU2 for NT 4 0 into the floppy drive Press lt Enter gt again The list of SCSI Adaptec AHA adapters appear with the last item selected Adaptec 294xU2 295xU2 395xU2 AIC 789x PCI SCSI Controller Press lt Enter gt once again The system loads the driver and it is added to the list of mass storage devices whose support is to be loaded Press lt Enter gt to initiate file loading When the Welcome to Setup screen appears press lt Enter gt to continue 9 When prompted press lt Enter gt twice to continue 10 In the opened licence Agreement page scroll down to the bottom using the lt PgDw gt key and press lt F8 gt 11 If the disk does not have NT installed a message is displayed press lt Enter gt Otherwise the disk
161. irectly to eNTEGRA P Link data must first be sent to a Starcam system and then to the eNTEGRA eNTEGRA P amp R Service Manual Direction 2263784 100 5 14 Rev 5 June 17 2001 System Description Software Description 5 2 6 DICOM The eNTEGRA system contains a DICOM server To describe the functionality of the DICOM server the following terms will be used Application Entity AE This is a networking term used to define a program that provides a specific application In DICOM this is the server or servers that provide the DICOM services The server name is referred to as the AE Title Service Object Pair SOP Class This defines the functionality of the AE The SOP Class is a combination of a Information Object i e Nuclear Image and a DICOM Message Service Element DIMSE For example the Nuclear Storage SOP Class combines the Nuclear Image Object and the C Store DIMSE This SOP Class allows the DICOM server to send or receive a Nuclear image depending on it service role Service Class User SCU This is the client role definition for the AE If a system supports the Nuclear Storage SOP Class in the SCU role it can send a Nuclear Image to a remote system Service Class Provider SCP This is the server role definition for the AE If a system supports the Nuclear Storage SOP Class in the SCP role it can receive a Nuclear Image sent from a remote system eNTEGRA P amp R Service Manual Direction 2263784 100 5 15
162. issues the DASM VDB interface is no longer being offered The 952 commands host control are sent from the DASM LCAM s 25 pin female RS422 port to the 37 pin RS422 host communication port on the Fuji Multiformatter interface The Multiformatter interface then converts the 952 commands into a Fuji compatible command set and sends it to the Lasercamera Since the RS422 interface on the Multiformatter interface is a 37 pin male connector a 25 pin male to 37 pin female cable is required 46 296980G1 can be used The DASM LCAM sends the high resolution digital image data over a 37 pin 8 bit parallel RS485 interface to the Fuji Multiformatter interface The Multiformatter interface then converts the digital image into a Fuji compatible image format and sends it to the Lasercamera Section 3 10 5 2 provides the basic procedure for interfacing configuring the Fuji Multiformatter to eNTEGRA Section 3 10 5 3 provides details on interfacing the Fuji Multiformatter to the eNTEGRA Section 3 10 5 5 provides details on configuring the eNTEGRA and the Lasercamera for optimal image quality eNTEGRA P amp R Service Manual 3 58 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options 3 10 5 2 Basic Procedure This section provides the basic procedure to interface and configure a DuPont Lasercamera with eNTEGRA 1 Verify that the DASM LCAM is connected configured properly and the Lasercamera has been added
163. ith the license file names Table 6 1 eNTEGRA P amp R Options Option Basic System license File Name ar base db base dc base hc base iap base pr base rec base pr 3d CEqual cequal CEqual Light cequalite ECToolbox cequal perfspect3degs tetrofosmin EC Toolbox Upgrade perfspect3degs tetrofosmin Functional Anatomical Mapping Fusion fam TI201 database upgrade TL201 QuantEM quantem Quantitative Gated SPECT qgspect Aladdin Compose and Edit qcard 3D Volume Rendering PerfSPECTive render3d CT MR DICOM Storage ctmrdicomscp Remote Connectivity remoteconn Iterative Reconstruction rec ir Quantitative Perfusion SPECT qps OSI required for connection to SP and osi StarCam systems eNTEGRA P amp R Service Manual 6 28 Direction 2263784 100 Rev 5 June 17 2001 Software Installation Installing eNTEGRA Software Options and Licenses 6 4 2 Installing the OSI Option 6 4 2 1 Overview The OSI option is required for any NT based ENTEGRA P amp R system that needs to communicate with other systems that do not support TCP IP These systems include Starcam systems running Starlink V4 protocol and SPX systems residing on the ApexNet The Starlink protocol and the SPX systems use the OSI network stack as it s transport software The standard eNTEGRA Operating System loaded on the eNTEGRA P amp R PC platform does not
164. k right on My Computer icon and select the Properties entry Click on the Performance tab Click the Change button With Drive C highlighted change the Initial Size MB to 540 Change the Maximum Size MB to 560 Click the Set button Click OK and close the Virtual Memory window Close the System Properties window When prompted click Don t Restart eNTEGRA P amp R Service Manual 11 Rev 5 Direction 2263784 100 June 17 2001 Installing Internet Explorer 5 C 8 5 Setting the View Options l 2 Double click My Computer icon In the opened My Computer window click the View option in the Menu Bar and select the Options entry 3 Inthe Options window click the Folder tab Click the radio button next to Browse folder by using a single window that changes as you open each folder then click the Apply button 5 Click the View tab in the Options window 6 Click the radio button next to Show all files option Uncheck the option Hide file extensions for known file types click OK to close the Options window Close My Computer window C 9 Installing Internet Explorer 5 1 For the English version skip to Step 2 below For other languages replace the eNTEGRA application CD with the eNTEGRA Accessories Software CD 2 Double click on My Computer icon located on the desktop 3 Double click the D drive CD ROM Drive P Cn For the English version skip to Step 5 below
165. l User Interface GUI Clinical Applications Object Definition Application Licenses ISG META 4 Object Control D e se oso 38 ot Pappa fe A Servers License Level Operating System Windows NT 4 0 Hardware Figure 5 5 Software Structure The eNTEGRA application includes nine servers that provide its functionality Presentation Server Preserver assigned to Port 2020 which manages the graphical user interface Database Server DbServer assigned to port 8100 which controls the access to the patient database Hardcopy Server HcServer assigned to port 4040 which controls the hardcopy functions Reconstruction Server Recserve assigned to port 5050 provides the required mathematical processing capabilities Communication Server cpipcserver assigned to port 3090 which controls the access to the network for remote database hardcopy and file transfer DICOM Server DicomServer assigned to port 104 which provides connectivity to DICOM systems via the Network Server Archive Server ArServer assigned to port 4848 which maintains the local archive eNTEGRA P amp R Service Manual Direction 2263784 100 5 10 Rev 5 June 17 2001 System Description Software Description e Archive Log Server ArchiveLog assigned to port 8099 which manages the Archive Log Index on the disk e Optical Disk Server Gemod assigned to port 7070 which manages the Optical Disk
166. lation process should take 1 person approximately 2 hours to complete 3 1 3 General Requirements 3 1 3 1 Special Tools and Fixtures None 3 1 3 2 Seismic Anchoring Systems to be installed in areas of the world subject to earthquakes may require seismic anchoring The Service Representative should check with local authorities in the country region of installation 3 1 3 3 Pre Installation Check List Completed Before commencing with the installation ensure that the site preparation check list found in the Site Preparation Manual 2264704 100 is completed Not The network backbone and node drops should be installed prior to starting the Note eNTEGRA P amp R installation eNTEGRA P amp R Service Manual 3 2 Rev 5 Direction 2263784 100 June 17 2001 Installation Overview 3 1 3 4 Compatible Options The available options for eNTEGRA are listed in Table 3 1 Table 3 1 Options Description Section DASM LCAM Section 3 6 General Hardcopy Info Section 3 10 3 1 3 5 Recording Installation Time Note The standard installation code is 03 Anything not part of a standard installation shall be booked against one of the numbers in Table 3 2 It would not be uncommon on a NORMAL installation to find time booked to one or more of these codes Table 3 2 Non installation Time Codes Code Description 04 Site preparation or inspection 06 Non standard installa
167. les or Folders and type in the named field winvnc exe 20 Click on Find Now 21 Click right on the winvnc exe icon and select Create Shortcut 22 Click Yes to create a shortcut on the desktop eNTEGRA P amp R Service Manual 6 25 Rev 5 Direction 2263784 100 June 17 2001 Software Installation Software Load from Warm 6 3 Software Load from Warm 6 3 1 Overview Software load from warm is mainly used for software upgrade 6 3 1 1 Time Required Since upgrade of the eNTEGRA application does not affect the database and the various settings system settings the network settings and the printer settings it requires 5 minutes only 6 3 1 2 Procedure Software upgrade consists of the following steps to be performed in the given order 1 Full Shut Down of the eNTEGRA Application on page 6 26 2 Software Upgrade on page 6 26 6 3 2 Full Shut Down of the eNTEGRA Application 1 From the Main eNTEGRA screen click the X shutdown button in the upper right corner of the screen 2 In the opened dialog click the Full button 3 Wait until the eNTEGRA application and its servers are closed 6 3 3 Software Upgrade Double click on My Computer icon located on the desktop Double click the E drive CD ROM Drive Double click on the ENTEGRA directory Double click setup exe Click Next When prompted to define the database location type D DataBase and click Next 7 Click Finish NO Ok a
168. ll use the password elgems 7 Retype the password and click Next 8 When prompted select no do not create an emerging repair disk and click Next 9 In the opened Windows NT Components dialog select Install the most common components and click Next 10 Upon the message Installing Windows NT networking click Next 11 Check Do not connect this computer to a network at this time and click Next 12 In the opened Date Time Properties window a Set the appropriate date and time in the Date amp Time page b Click the Time Zone tab click on the down arrow to display the Time Zone list select the appropriate Time Zone and click OK c Click Close 13 If the system finds the video adapter click OK then click Cancel for Video card driver installation which will be installed later As long as the display driver is not installed an Invalid Display Settings error message will be displayed after each reboot Click OK and ignore the message 14 When asked to restart the computer remove the windows NT CD and press the Restart button 15 When prompted press lt Alt gt lt Ctrl gt lt Del gt and login into the system with User Name Administrator Password elgems the password entered at Step 6 above 16 For systems with 3Com adapters only a Insert the eNTEGRA Application CD into the CD ROM drive b Select Start gt Programs Windows NT Explorer eNTEGRA P amp
169. lling the eNTEGRA system The instructions are provided in the following break down Section 3 1 Overview on page 3 2 which includes o Section 3 1 1 How to Use This Chapter on page 3 2 Section 3 1 2 Estimated Cycle Time on page 3 2 o Section 3 1 3 General Requirements on page 3 2 o Section 3 1 4 Installation Flow Chart on page 3 4 Section 3 2 Unpacking on page 3 5 Section 3 3 Isolation Transformer Installation on page 3 7 Section 3 4 PC Installation on page 3 8 Section 3 5 Connect Peripheral Tower on page 3 10 Section 3 6 DASM LCAM Option on page 3 11 Section 3 7 Initial System Power up on page 3 12 Section 3 8 Site Configuration on page 3 14 Section 3 9 Remote LAN Configuration on page 3 28 Section 3 10 Hardcopy Options on page 3 33 Section 3 11 InSite Entitlement on page 3 88 Section 3 12 Backup on page 3 90 Section 3 13 Commissioning on page 3 90 Section 3 14 Completion on page 3 90 eNTEGRA P amp R Service Manual Direction 2263784 100 3 1 Rev 5 June 17 2001 Installation Overview 3 1 Overview 3 1 1 How to Use This Chapter The installation procedure is diagramed in a flow chart Figure 3 1 so that specific tasks are completed in the correct order and in an efficient manner The manual itself closely follows the flow chart In addition the manual includes instructions for installing hardware options as upgrade 3 1 2 Estimated Cycle Time The instal
170. ltiformatter Interface Configuration Interface Parameter Setting Host Communications Baud Rate 1200 Stop Bits 1 Data Bits 8 Parity Even Parity Enable Enable Character Pacing 0 End Of Message CR Protocol ACK NACK Host Protocol Type 952 Image Image Size 1024x1024 Pixel Width 8 Parity Even Parity Enable Enable 3 10 5 5 Image Quality Configuration The 952 protocol image quality parameters defined in HCdefaults win32 file are ignored by the Fuji Multiformatter All image quality adjustment should be performed by the Fuji Service Engineer eNTEGRA P amp R Service Manual Direction 2263784 100 Rev 5 June 17 2001 Installation Hardcopy Options 3 10 6 Konica Lasercameras Configuration 3 10 6 1 Overview This section provides details on how to connect the Konica Lasercameras to the eNTEGRA system and how to configure both the eNTEGRA and Lasercamera to produce good quality films The eNTEGRA hardcopy server sends commands and high resolution digital image data to the DASM LCAM over the SCSI 2 bus using the Analogic DASM SCSI command set The DASM LCAM converts these commands into the 952 commands and a digital image The 952 commands host control are sent from the DASM LCAM s 25 pin female RS422 port to the RS422 host communication port on the Konica Lasercamera s input module Konica s Service Engineer will need to provide any hardware required to in
171. m Prn3m 952 stage timeout 60 __ e Edit for MMU Interface Prn3m 952 expose timeout 15 Prnam 952 density I l _ _ Edit to change Density Prn3m 952 Hcp code_path usr lib HCP_RPC out Prn3m 952 Hcp unit 0 Prn3m 952 Hcp parity_enable on Prn3m 952 Hcp even_parity on Prn3m 952 Hcp local_loop off Prn3m 952 Hcp auto_lf off Prn3m 952 Hcp data_rate 1200 Prn3m 952 Hcp stop_bits 0 Prn3m 952 Hcp data_bits 8 Prn3m 952 Hcp line_term CR Prn3m 952 Hcp data_interface digital VRE PEPE EVE DEE TREY PE YE OTS PPE ee Peery Pe ee eae protocol 952 with the Lcam interface 1 Prn3m 952 Lcam devname Prn3m 952 Lcam debug_file Prn3m 952 Lcam parity_enable Prn3m 952 Lcam even_parity with MMU Prn3m 952 Lcam data_rate no MMU Prn3m 952 Lcam data_rate Prn3m 952 Lcam stop_bits Prn3m 952 Lcam data_bits Prn3m 952 Lcam local_loop Prn3m 952 Lcam auto_lf Prn3m 952 Lcam line_term Digital data interface Prn3m 952 Lcam data_interface Analog video interface in ISG Prn3m 952 Lcam data_interface 1 Prn3m 952 formats dev rdsk c201d4s0 debug out on on 1200 9600 1 8 off off CR digital analogue 1 2 3 4 6 9 12 16 20 format 1 Prn3m 952 1 desc 1 on 1 1 frame on 1 zone Prn3m 952 1 zones 1 Prn3m 952 1 1 frames ak Prn3m 952 1 1 width 1024 Prn3m 952 1 1 height 1024 Prnom 952 1 1
172. mbers to be dialed in case that the primary number can not be reached a Click Alternates A dialog is opened b For each alternate number type in an alternate number and click Add This number is added to the phone numbers list Note You can add replace or delete alternate phone numbers as well as sort the list c When all the alternate numbers have been added click OK 8 Click Next until you return to the Dial Up Networking dialog 9 For each entry to be added to the phonebook click the New button in the Dial Up Networking dialog and repeat steps 4 through 8 10 In the Dial Up Networking dialog while the first dial up server is highlighted click the More button eNTEGRA P amp R Service Manual 3 23 Rev 5 Direction 2263784 100 June 17 2001 Installation Site Configuration 11 12 13 14 15 16 17 18 19 20 In the opened pull down list select the Edit entry and modem properties entry In the opened Edit Phonebook Entry dialog select the Server tab to bring forward the Ras Server properties Pull down the Dial up server type list and select the PPP Windows NT Windows 95 Plus Internet entry In the opened Network protocols list check TCP IP Click the TCP IP Settings button In the opened PPP TCP IP Settings dialog a Click the radio button next to Server assigned IP address b Click the radio button next to Server assigned name server addres
173. mp R Service Manual 3 55 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options 3 10 4 3 Lasercamera Connection This section provides details on how to interface the DuPont Lasercamera to the eNTEGRA system via the DASM LCAM a Interface Wiring Figure 3 12 and Table 3 20 detail the interface between the eNTEGRA and the DuPont Lasercameras using the DASM LCAM m DASM LCAM Q 120 VAC l Lasercamera Interface DuPont Lasercamera Figure 3 12 eNTEGRA to Dupont Lasercamera Interconnection via the DASM LCAM Table 3 20 DASM LCAM to DuPont Lasercamera Cable Summary me Description Part Source Length Reference 1 Peripheral Tower SCSI 46 325201P5 1m Section 5 1 3 Cable 2 37 Pin LCAM Image Sterling Sterling Service Engineer Data Cable RS485 3 25 Pin Male to 37 Pin 46 296980G1 30 cm GEMS or Sterling Female RS422 Stub Cable 4 37 Pin RS422 Host Sterling Sterling Service Engineer Communication Cable 5 Lasercamera Interface Network or Serial Note Refer to Section 5 1 3 1 for pinout details on the DASM LCAM eNTEGRA P amp R Service Manual Direction 2263784 100 3 56 Rev 5 June 17 2001 Installation Hardcopy Options b Interface Configuration The SID must be configured to communicate with the eNTEGRA Table 3 21 summarizes the
174. n setup exe 4 Follow the instructions displayed on the screen 5 Click on Finish to restart your computer and proceed to Installing Service Pack 6a on page B 10 eNTEGRA P amp R Service Manual 9 Rev 5 Direction 2263784 100 June 17 2001 Installing Service Pack 6a B 8 Installing Service Pack 6a This installation depends on the language being used 1 For English version Insert the eNTEGRA Application CD into the CD Drive and double click the My Computer icon located on the desktop For other languages Insert the eNTEGRA Accessories Software CD into the CD Drive and double click the My Computer icon located on the desktop 2 Double click the D drive CD ROM Drive For the English version skip to step 4 below For other languages double click the applicable language Double click the SP6 directory Double click SP6ai386 exe Check the Accept License Agreement box if requested aa Uncheck Backup files necessary to uninstall service pack Click Install When prompted click on Restart to reboot the system and logon as before P00 ON A 10 Proceed to Setting System Options on page B 10 B 9 Setting System Options Set the following operating system configurations in the given order Setting the Date Format on page B 11 Setting the Application Event Viewer Loggings on page B 11 Setting the Task Bar Properties on page B 11 Setting the Virtual Memory on page B 12 Setting the View
175. n Description Part Source Reference 1 eNTEGRA CAT 5 Cable GEMS Section 5 1 3 10 Base T Transceiver for Codonics Codonics or GEMS Codonics Users Manual Codonics CAT 5 Cable Ri wy N 10 Base T HUB GEMS b Interface Configuration The Codonics must be configured to communicate with the eNTEGRA Refer to the Codonics Users Manual for details on setting these parameters Table 3 30 summarizes the configuration parameters that need to be set on the Codonics Table 3 30 Codonics Interface Configuration Parameter Setting IP Address for Codonics IP Address assigned to Codonics Netmask Optional Subnet Mask assigned to LAN eNTEGRA P amp R Service Manual 3 73 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options 3 10 8 4 Codonics Upgrade To enable proper communication with the eNTEGRA the Codonics must be upgraded as follows 1 l ad Dy eS Ensure that no one is suing the printer Make sure no one is using the printer Open a command line window Start Programs Command Prompt Type E lt Enter gt where E stands for your CD Drive Type cd Drivers Printers codonics Patch1 6 lt Enter gt Type ftp codonics_IP_Address lt Enter gt When prompted enter User Name your first name Password 300 Type bin lt Enter gt The system responds 200 Type set to Type hash lt Enter gt The system responds Hash mark p
176. n parameters that need to be set on Kodak Lasercamera for the DASM LCAM interface The Kodak Service Engineer will be responsible for setting these parameters on the Lasercamera Table 3 18 DASM LCAM to Kodak Lasercamera Interface Configuration Part 1 Interface Parameter Setting Host Communication Baud Rate 1200 Stop Bits 1 Data Bits 8 Parity Even Parity Enable Enable Character Pacing 0 End Of Message CR Protocol ACK NACK Host Protocol Type 952 Image Image Size 1024x1024 Parity Enable Enable Parity even Pixel Width 8 Horizontal Pixel Aspect 1 Vertical Pixel Aspect eNTEGRA P amp R Service Manual Direction 2263784 100 Rev 5 June 17 2001 Installation Hardcopy Options Note c HCdefaults win32 Configuration The HCdefaults win32 file must be edited in order for the eNTEGRA hardcopy server to properly work with a Kodak Lasercamera The following changes need to be made The ISG3m version parameter must be changed from 3M to KODAK e The Kodak model must be defined via the ISG3m model parameter The contrast parameter Prn3m 952 fmt n contrast must be changed from D to 20 for a negative image polarity black on white for each frame definition Use a value of 5 for positive image polarity white on black Kodak s implementation of the 952 protocol uses the Prn3m 952 fmt n contrast parameter only to set the image pola
177. n shows the option S Specify Additional Device 3 Press lt S gt The SCSI Adapter list appears with Other selected 4 Press lt Enter gt and insert the diskette labeled SCSI Driver 2940U2 for NT 4 0 into the floppy drive 5 Press lt Enter gt again The list of SCSI Adaptec AHA adapters appear with the last item selected Adaptec AHA 294xU2 295xU2 AIC 789x PCI SCSI Controller 6 Press lt Enter gt once again The system loads the driver and it is added to the list of mass storage devices whose support is to be loaded 7 Press lt Enter gt to initiate file loading 8 When the Welcome to Setup screen appears press lt Enter gt to continue 9 When prompted press lt Enter gt twice to continue 10 In the opened licence Agreement page scroll down to the bottom using the lt PgDw gt key and press lt F8 gt 11 If the disk does not have NT installed a message is displayed press lt Enter gt Otherwise the disk already has NT installed a message is displayed Press lt N gt New to reinstall NT Press lt Enter gt Press lt D gt Delete to delete the current partition Press lt Enter gt Press lt L gt Delete If there is an additional partition press the lt gt key to highlight it and repeat the procedure to delete this partition press D then press lt Enter gt and press L 12 Upon the message Create the following partitions in the whole disk unpartitioned space moaogp
178. nalyze the image and determine if additional adjustments are required Any adjustments for image quality will be made via the HCdefaults win32 file Refer to Section 3 10 10 4 Repeat steps 5 through 7 until optimal film quality is achieved eNTEGRA P amp R Service Manual 3 82 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options 3 10 10 3 Printer Interface This section provides details on how to interface the DICOM Printers to the eNTEGRA system via the LAN Figure 3 20 and Table 3 34 detail the interface between the eNTEGRA and the DICOM Printer CI pier z 10 100 Base T HUB Figure 3 20 eNTEGRA to DICOM Printer Interconnection Table 3 34 DICOM Printer Network Interface Cables ae Description Part Source Reference 1 eNTEGRA CAT 5 Cable GEMS Section 5 1 3 2 10 Base T Transceiver fro printer Printer Vendor or GEMS Printer User s Manual 3 Printer s CAT 5 Cable 4 10 Base T Hub GEMS eNTEGRA P amp R Service Manual 3 83 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options 3 10 10 4 Configuration The Basic Grayscale and Color Management SOP Classes provide a number of configurable parameters for image quality These parameters are either set by the printer or sent by the eNTEGRA The paramet
179. nd login into the system with Username entegra Password entegra 2 Click OK 3 In the opened Welcome window click on the checkbox for Show this Welcome to deselect it and click Close 4 Double click the My Computer icon on the Desktop 5 Double click Control Panel 6 Double click Display 7 In the opened Display Properties window click the Settings tab 8 Click the Display Type button 9 Click the Change button 10 In the Change Display dialog click on the Have Disk button 11 Type in the Copy Manufacturer s files from input field C drivers nvidia and click OK 12 From the opened nvidia drivers list select NVIDIA RIVA TNT2 Model 64 and click OK 13 In the confirmation window click Yes and OK 14 Close the Display Types window by clicking Close 15 Close the Display Properties window by clicking OK 16 Click OK to reboot the computer 17 Proceed to Adjusting the Display Properties on page 6 12 eNTEGRA P amp R Service Manual 6 11 Rev 5 Direction 2263784 100 June 17 2001 Software Installation Software Load From Cold For Dell OptiPlex GX200 6 2 8 Adjusting the Display Properties 1 De oe a os When the system comes up press lt Alt gt lt Ctrl gt lt Del gt and login into the system with Username entegra Password entegra Click OK If the Invalid Display Settings window is opened click OK The Display Properties window is
180. nics Image Quality Parameters Print Device Parameters Default Parameter Description Setting GAMMA This parameter allows the user to adjust the lightness 1 0 darkness level of the images The amount of correction is specified by a single value ranging from 0 0 to 10 0 MCM MCM stands for Medical Color Matching It is a set of N A look up tables that adjust the printed output colors to more accurately match the output of the CRT monitor LUTs assigned to GEMS are 8 10 12 and 14 a Creating the Codonics User Preference File The User Preference file can be created using the Notepad editor on the eNTEGRA This file is then sent to the Codonics using the ftp command The following procedure details this process using the Notepad editor and ftp 1 Click on the minimize icon on the eNTEGRA Main screen 2 Click Start on the Task bar select Run type cmd and click OK 3 In the opened Command Line window type notepad codon set lt Enter gt 4 Type the following string and data to enter the GAMMA and MCM values GAMMA 1 5 lt Enter gt MCM 12 lt Enter gt eNTEGRA P amp R Service Manual 3 75 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options 5 Save the changes and quit the notepad editor by selecting File Save File Exit 6 Type the following command string to open an ftp session ftp codonics lt Enter gt The system responds with Name codonics username
181. ns to perform electrical servicing on the equipment DAMAGE IN TRANSPORTATION All packages should be closely examined at time of delivery If damage is apparent write Damage in Shipment on ALL copies of the freight or express bill BEFORE delivery is accepted or signed for by a Vendor s representative or hospital receiving agent Whether noted or concealed damage MUST be reported to the carrier immediately upon discovery or in any event within 14 days after receipt and the contents and containers held for inspection by the carrier A transportation company will not pay a claim for damage if an inspection is not requested within this 14 day period Call Vendor s representative immediately after damage is found At this time be ready to supply name of carrier delivery date consignee name freight or express bill number item damaged and extend of damage Me Of AVERTISSEMENT AS HEE FT RA RR SPR CA BIR MHRCEM DA AIAR Hit LPARAM RASM SH KEM RA H 47 HEB AMSTEL ZIHER BRE A BR AA fh E DR a REC HE ZLOY KAV AY WILKEROATT RP ate Reb urea ae PAR Biche oT HRADOV AA COBFOB ECHRY CAR ENN MOREY ECEAT ATHEA aT kB RRL KET PRR OR SU LOBE ERFURUGA YERE BURA DARRE REPRE E RIES BREEDS DH DV ETOCOERB PAW THIS SERVICE MANUAL IS AVAILABLE IN ENGLISH ONLY IF A CUSTOMER S SERVICE PROVIDER REQUIRES A LANGUAGE OTHER THAN ENGLISH IT IS THE CUSTOMER S RESPONSIBILITY TO PROVIDE TRANSLATION SERVICE
182. o exit User Preferences window eNTEGRA P amp R Service Manual 3 19 Rev 5 Direction 2263784 100 June 17 2001 Installation Site Configuration Table 3 10 DICOM Configuration Parameters Application Port Flags System Type Station Name IP Address Service Entity Class eNTEGRA Limitations Per system s Host name in 104 Send e Less than 12 charac TCP IP upper case Query ters configuration letters Fetch l e Only letters a z A Genie P amp R Z Numbers 0 9 or Host name in 2030 Send underscores _ are Upper case Query allowed letters Fetch XPert As defined by 104 Send the local system Query administrator Fetch Case Sensitive Genie Acq Host name in 2030 Query upper case Fetch letters Millennium VG As defined by 104 Query the local system Fetch administrator Case Sensitive Other Systems Refer to the system s DICOM Conformance statement eNTEGRA P amp R Service Manual 3 20 Rev 5 Direction 2263784 100 June 17 2001 Installation Site Configuration 3 8 4 7 Interfile Configuration 1 Click the Configuration button on the upper left corner of the Main screen then click Advanced Configuration Click the Interfile tab For each remote Interfile station a Click the Add button b Type in the Remote station s Hostname and click OK c Enter the IP Address of the remote Interfile station and click OK
183. ocedure to interface and configure the Helios Lasercamera with eNTEGRA 1 2 Obtain an IP Address for the Helios Verify that the Helios was configured correctly on the eNTEGRA Refer to Section 3 6 for details The Device Type should be set to helios The IP Address of the Helios will also need to be entered Install and connect the Helios to the Nuclear LAN This should be done by the Sterling Service Engineer Refer to Section 3 10 7 3 Configure the Helios for communication with the eNTEGRA This includes assigning the Helios s IP Address Subnetmask optional and adding the eNTEGRA s IP Address to the Helios This should be done by the Sterling Service Engineer Refer to Section 3 10 7 3 Power up the Helios Log into eNTEGRA select the Formatter Static image from the Default Patient Calibration study and click the New icon located on the Patient Selector Control Bar Click the Camera tool in the Display Screen Click the Down Arrow in the Film dialog select the Helios Lasercamera and click Submit If a No image is printed refer to Section 8 2 5 for details on troubleshoot ing b An image is printed analyze the image and determine if additional adjustments are required Any adjustments for image quality will be made via the HCdefaults win32 file Refer to Section 3 10 7 4 Repeat steps 6 and 7 until optimal film quality is achieved eNTEGRA P amp R Service Manual 3 67 Rev 5 Direction 226
184. ode normally Tone e Country the default country is US Canada For any other country select from the list e CPU Serial Port Speed select 57600 Click APPLY Note ignore the status bar message No response from modem Please check hardware installtion c Ifthe Modem Readme window appears proceed according to your modem type as follows e For U S Robotics modem verify that the DIP switch settings match the display and click OK e For Motorola follow the displayed instructions and click OK d In the Modem Properties window that appears click Close e In the Install Modem window click OK 6 On the InSite Checkout tab a Type in the InSite IP address the Modem IP address as defined by the OLC for the local system b Type in the Router IP address the SIR IP address which belongs to the same subnet as the local system This is obtained from the network administrator or the OLC c Click CHECKOUT NOW eNTEGRA P amp R Service Manual 3 88 Rev 5 Direction 2263784 100 June 17 2001 Installation InSite Entitlement d Inthe Reboot Needed window click OK e Click Exit at the bottom right of the InSite Interactive Platform Con figuration window f Inthe Exit Confirmation window click OK 7 Type exit lt Enter gt in the opened iLing Shell window Only for systems with Multitech MT5634ZBA modem turn OFF the modem wait 5 seconds and then turn it ON 9 Reboot the System for the chang
185. of a local connected printer you plug the printer into the activator 3 5 Connect Peripheral Tower 3 5 1 Introduction In the case of an upgrade from the HP715 100 platform there may be a peripheral tower containing the Archive Optical Disk and or the DASM LCAM Digital Lasercam Interface that needs to be interfaced to the system If there is no peripheral tower with the system proceed to the Section 3 6 3 5 2 Installation Procedure Table 3 6 Peripheral Tower Option Installation Procedure Time Steps Min Reference Unpack and Position 5 Peripherals Tower per customer s specifications Open the tower and 5 configure the DASM LCAM as follows Refer to the DASM LCAM User Manual e SCSI ID 4 D Host Comm RS422 Connect SCSI cable 10 Figure 5 1 and the PC User s Guide between the PC and the peripheral tower Install the SCSI terminator on the tower Connect power cord to In above Figure 5 1 Isolation Transformer Total 20 eNTEGRA P amp R Service Manual 3 10 Rev 5 Direction 2263784 100 June 17 2001 Installation DASM LCAM Option 3 6 DASM LCAM Option Not If the DASM LCAM option is included refer to Section 3 10 for complete details on a interfacing configuring the DASM LCAM with the various compatible Lasercameras 3 6 1 Introduction The DASM LCAM is a self contained unit that provides a digital interface to a 3M 952 compatible Lasercamera e The unit is c
186. oftware load from cold is used when the hard disk is corrupted or replaced and the entire package must be installed from scratch CAUTION A Load from cold is a destructive procedure and all the data on the disk will be lost Verify that all patient data is backed up Back up the Archive Log Index directory C ArcLog before starting the software load from cold procedure B 1 1 Time Required The time required to complete the installation of the basic software is 1 5 hours about 90 minutes eNTEGRA P amp R Service Manual 1 Rev 5 Direction 2263784 100 June 17 2001 Overview B 1 2 Procedure Overview The load from cold procedure consists of the following steps to be performed in the given order 1 SOP 00 a ON OU ag i e SS w N e e o 14 15 16 17 Installing the Windows NT Operating System on page B 3 including disk partitioning and formatting Drive C Installing Windows NT Networking on page B 4 Installing Service Pack 6a on page B 7 Installing the Display Driver amp Adjusting the Display on page B 8 Installing the Sound Driver on page B 9 Installing the HP Multimedia Keyboard Utility on page B 9 Installing Service Pack 6a on page B 10 Setting System Options on page B 10 Installing Internet Explorer 5 on page B 13 Installing RAS Modem and TCP IP for Printing on page B 14 Installing the FTP Service on page B 15 Formatting Drive D as NTFS on page B 16 Installing
187. olation Transformer 115 V 115 V amp 220 V 115 V versions Modem Country Specific DASM LCAM Optional 952 Lasercam Digital Interface 2 2 1 Catalog Product Structure The basic eNTEGRA system is delivered in several configurations with respect to the regulatory kit one of two available and an optional localization kit which includes a matching keyboard and Operator s Manual In all delivery options Windows NT Ver 4 0 and eNTEGRA R1 0 or current version are pre loaded Table 2 3 summarizes the available basic system configurations by Catalog number Table 2 4 summarizes the available hardware and software options by Catalog number eNTEGRA P amp R Service Manual 2 3 Direction 2263784 100 Rev 5 June 17 2001 Introduction The eNTEGRA System Table 2 3 Basic eNTEGRA System Catalog Numbers Description Catalog Contents Number Basic System H3400ZA Pentium Based PC workstation Windows NT ver 4 0 Operating System eNTEGRA R1 0 Application Software Documentation Kit including Operator s Manual CD with on line help for all available applications Release Notes and Service Manual all in English Monitor either of H3300TB 19 High Resolution Color Monitor H3000TA 21 High Resolution Color Monitor Regulatory Options American Regulatory Kit H3400LB 3Com Modem Isolation Transformer USA version CE Regulatory Kit H3400LC
188. onnected to the PC via the SCSI bus e The Lasercamera interface is via a 25 pin RS422 serial communication Host line and a 37 pin digital Image line If there is no DASM LCAM option included proceed to Section 3 7 The DASM LCAM can not be used if a MFHD or MF96 is also being used due to SCSI bus conflicts Important 3 6 2 Installation Procedure Table 3 7 DASM VDB Option Installation Procedure Time Steps Min Reference Unpack and Position DASM LCAM 5 Configure the DASM LCAM as follows 5 Refer to the DASM e SCSI ID 4 LCAM Users Manual Host Comm RS422 Connect SCSI cable between the PC and 10 DASM LCAM Users DASM LCAM Manual and the PC Install the SCSI terminator on the DASM LCAM User s Guide Connect power cord to Isolation In above Figure 5 1 Transformer Total 20 Refer to Section 3 8 for details on configuring the eNTEGRA system to use the Note Lasercamera connected to the DASM LCAM for filming Refer to Section 3 10 for complete details on interfacing configuring the DASM LCAM with the various compatible Lasercameras eNTEGRA P amp R Service Manual 3 11 Rev 5 Direction 2263784 100 June 17 2001 Installation Initial System Power up 3 7 Initial System Power up 3 7 1 Procedure Table 3 8 Initial System Power up Procedure Steps Time Min Reference Apply power to all peripherals and to 4 the system Log into the system
189. oot Proceed to Installing RAS Modem and TCP IP Printing on page 6 16 On SO A eNTEGRA P amp R Service Manual 6 15 Rev 5 Direction 2263784 100 June 17 2001 Software Installation Software Load From Cold For Dell OptiPlex GX200 6 2 12 Installing RAS Modem and TCP IP Printing 1 When the system comes up press lt Alt gt lt Ctrl gt lt Del gt and login into the system with Username entegra Password entegra 2 Click OK and wait for the Windows desktop 3 Insert the Windows NT Workstation CD ROM and close the opened Windows CD window 4 Click right on the Network Neighborhood icon on the desktop and select the Properties entry 5 In the opened Network window select the Services tab to display the currently installed services 6 In the Services tab click Add select Microsoft TCP IP Printing 7 Click OK type D i386 lt Enter gt where D is your CD ROM drive and click Continue 8 In the Services tab click Add select the Remote Access Service entry and click OK 9 If needed change the path displayed to D i386 where D is your CD ROM drive and click Continue 10 The Remote Access Service files will be copied 11 When the following message appears There are no RAG click Yes to invoke Modem Installer 12 In the opened Install New Modem dialog check the Don t detect my modem and click Next 13 Proceed according to the installed modem as follows a In
190. operties for entegra dialog On the Service tab uncheck Allow only anonymous connections and confirm by clicking Yes Click the Directories tab select the displayed entry click Edit Properties check click the Write property then click OK Click Add enter C in the Directory field enter C in the Alias field click the Write checkbox located at the bottom of the screen and click OK Click Add enter D in the Directory field enter D in the Alias field click the Write checkbox located at the bottom of the screen and click OK Click OK and close the Microsoft Internet Service Manager dialog Proceed to Formatting Drive D as NTFS on page 6 19 eNTEGRA P amp R Service Manual 6 18 Rev 5 Direction 2263784 100 June 17 2001 Software Installation Software Load From Cold For Dell OptiPlex GX200 6 2 14 Formatting Drive D as NTFS 1 Double click on the Start button in the Task Bar and select Programs Administrative Tools common Disk Administrator Click OK In the Disk Administrator dialog click right on the letter assigned to the CD ROM and select Assign Driver Letter From the Assign drive letter drop down list select E and click OK 5 In the confirm window click Yes 10 11 12 13 14 15 16 17 18 In the Disk Administrator dialog click right on Free Space and in the pop up window click Create When asked click Yes OK
191. ory 5 UTP cable to the RJ45 plug on the PC s Ethernet card e Connect the other end to either the o Open port on the HUB o RJ45 connection provided by LAN installer This connection should be tied back to the HUB Figure 3 2 provides an example of the LAN connections To connect to another IEEE802 3 topology 10Base2 or 10Base 5 the HUB will need to be interfaced to the current network bus via the HUB s AUI port and a topology specific transceiver This should have been completed during the site preparation work e A 10Base2 or ThinNet LAN consists of a 50 ohm RG58 coax cable backbone e A 10Base5 or ThickNet LAN uses thick 50 ohm coax cable as the backbone The node transceivers are connected to the backbone via a vampire tap or a end point connector t Starcam 2 Based i aen System Helios or Codonics CUT 5 UTP Cable 10 100BaseT HUB AUI Port Connection to other topology AUI Cable Thin or Thick Coax Network Bus 10Base5 or 10Base2 10Base5 or 10Base2 Transceiver Figure 3 2 eNTEGRA LAN Connection Examples eNTEGRA P amp R Service Manual 3 9 Rev 5 Direction 2263784 100 June 17 2001 Installation Connect Peripheral Tower 3 4 3 Plug in the Activator Plug the keyed activator into the parallel port on the rear panel of the computer In case
192. osoft Internet Service Manager dialog Proceed to Formatting Drive D as NTFS on page B 16 eNTEGRA P amp R Service Manual 15 Rev 5 Direction 2263784 100 June 17 2001 Formatting Drive D as NTFS B 13 Formatting Drive D as NTFS 1 Click on the Start button in the Task Bar and select Programs gt Administrative Tools common gt Disk Administrator 2 Click OK 3 Inthe Disk Administrator dialog click right on the letter assigned to the CD ROM and select Assign Driver Letter From the Assign drive letter drop down list select E and click OK 5 In the confirm window click Yes 6 In the Disk Administrator dialog click right on Free Space and in the pop up window click Create When asked click Yes OK and Yes 8 In the Disk Administrator dialog select Exit from the Partition drop 16 lig 18 down menu When asked click Yes to save the partition then click OK twice 10 11 12 13 14 15 Double click on My Computer icon located on the desktop Right click on D drive icon Select the Format entry Click the down arrow in the File System field and select NTFS entry Click the Start button The following warning will be displayed WARNING formatting will erase all data on this disk Select OK to format the disk Cancel to abort Click OK The disk will be formatted Upon system prompt Format Complete click OK Click Close P
193. oup 1 Class A Medical Devices as stated in EN 60601 1 2 However there is no guarantee that interference will not occur in a particular installation If the equipment is found to cause interference which may be determined by turning the equipment on and off the user or qualified service personnel should attempt to correct the problem by one or more of the following measures o Re orient or relocate the affected devices s Increase the separation between the equipment and the affected device Power the equipment from a source different from that of the affected device and or Consult the point of purchase or service representative for further suggestions To comply with the regulations on electromagnetic interference for a Group 1 Class A Medical Device all interconnect cables to peripheral devices must be shielded and properly grounded Use of cables not properly shielded and grounded may result in the equipment causing radio frequency interference in violation of the local regulations The manufacturer is not responsible for any interference caused by using other than recommended interconnect cables or by unauthorized change or modifications to this equipment Due to installation in less favorable environment this equipment may be exposed to electromagnetic and electrostatic interference To ensure a high level of reliability when exposed to such interference this equipment complies with the immunity requiremen
194. ove all Product Locator cards marked INSTALLATION from each package and put in a safe place until installation is complete Details on completing and mailing these cards are given in Section 3 14 3 eNTEGRA P amp R Service Manual 3 6 Rev 5 Direction 2263784 100 June 17 2001 Installation Isolation Transformer Installation 3 3 Isolation Transformer Installation If an isolation transformer will not be installed proceed to the Section 3 4 An isolation transformer is required if the eNTEGRA P amp R is located in the patient scanner area and for CE compliant installations Note Table 3 4 Isolation Transformer Installation Steps Time Min Reference Ensure Pre install 10 Pre Installation Check List in the Pre Complete Installation Manual Unpack amp Install 15 Section 3 3 1 Isolation Transformer Connect Isolation In above Figure 5 1 Transformer to Line Supply Total 30 3 3 1 Mounting Procedure The isolation transformer can either be mounted on a wall or positioned on the floor next to the eNTEGRA P amp R 1 Unpack isolation transformer and position near the workstation location 2 If the transformer will be mounted on the wall secure using four 11mm x 76 mm 7 6 x 3 anchor screws The wall mount must support the weight of the isolation transformer 17 2 kg Note 38 Ibs eNTEGRA P amp R Service Manual 3 7 Rev 5 Direction 2263784 100 June 17 2001 Install
195. py Options 3 10 9 3 Physical Interface This section provides details on how to physically interface the PostScript Printer to the eNTEGRA system either via the LAN or parallel port a LAN Interface Figure 3 18 and Table 3 32 detail the interface between the eNTEGRA and the PostScript printer via the LAN Fa PostScript Printer 10 100 Base T HUB Figure 3 18 eNTEGRA to PostScript Printer LAN Interface Table 3 32 PostScript Printer Network Interface Cable Cable Run Description Part Source Reference eNTEGRA CAT 5 Cable GEMS Section 5 1 3 10 Base T Transceiver for the Printer Customer or GEMS Printer CAT 5 Cable A Oo N 10 Base T Hub GEMS Note b Parallel Port Interface Figure 3 19 and Table 3 33 details the interface between the eNTEGRA and the PostScript printer via the eNTEGRA s parallel port Refer to PC User s Guide for information on the location of the eNTEGRA s parallel port PostScript Printer Mu To Printer s To eNTEGRA s Parallel Port Parallel Port Figure 3 19 eNTEGRA to Postscript Printer Parallel Port Interface Table 3 33 PostScript Printer Parallel Port Interface Cable Summary Cable Run 1 Description Part
196. quested Ts 8 9 Uncheck Backup files necessary to uninstall service pack Click Install When prompted click on Restart to reboot the system and logon as before 10 Proceed to Installing the Display Driver on page C 8 C 5 Installing the Display Driver 1 When prompted press lt Alt gt lt Ctrl gt lt Del gt and login into the system with Username entegra Password entegra 2 Click OK 3 In the opened Welcome window click on the checkbox for Show this Welcome to deselect it and click Close In the opened Welcome window uncheck Show this welcome if it is shown and click Close Insert the eNTEGRA CD into the CD drive Double click My computer D gt Drivers G400 Setup exe In the Setup window select the installation language and click Next then Typical then Next again and then Finish Proceed to Adjusting the Display Properties on page C 9 eNTEGRA P amp R Service Manual 8 Rev 5 Direction 2263784 100 June 17 2001 Adjusting the Display Properties C 6 Adjusting the Display Properties 1 ON ON ge ee a When the system comes up press lt Alt gt lt Ctrl gt lt Del gt and login into the system with Username entegra Password entegra Click OK If the Invalid Display Settings window is opened click OK The Display Properties window is opened to the Settings tab Click the down arrow under the Colo
197. r Palette and select True Color Move the slider in the Desktop Area to display a resolution of 1280 by 1024 pixels Click the down arrow under Font Size and select Small Fonts 8 Click the down arrow under Refresh frequency and select 75 Hertz 10 11 12 13 Click the Test button Click OK to display the test screen In the testing Mode window click Yes if you have seen the bitmap properly In the Display Properties window click OK Proceed to Installing the Sound Driver on page C 10 eNTEGRA P amp R Service Manual 9 Rev 5 Direction 2263784 100 June 17 2001 Installing the Sound Driver C 7 Installing the Sound Driver If necessary insert the eNTEGRA CD ROM to the CD ROM drive Double click the My Computer icon on the Desktop Double click Control Panel Double click Multimedia and click the Devices tab Click Add select Unlisted or Updated Driver and click OK Type in the path D Drivers Dell_Audio for the driver installation files and click OK ON FS a aa where D refers to the CD ROM drive 7 A dialogue box Add Unlisted or Updated Drivers appears Click OK 8 Ifthe Driver Exists window appears click on the New button 9 Click OK in the CrystalWare TM Audio Driver Window 10 Click Don t Restart Now 11 Close the multimedia properties dialogs 12 Close the Control Panel window and proceed to Procedure Overview on page C 10 C 8
198. rams or protocols are NOT validated nor warranted by ELGEMS Ltd The use of data obtained using such user provided programs or protocols is the sole responsibility of the party using such programs or protocols Users exchanging files and diskettes should beware of the risk of software viruses Published by ELGEMS Ltd P O Box 170 Tirat Hacarmel 30200 Israel Tel 972 4 8563666 Fax 972 4 8577663 ELGEMS Publication Number MAN000377 CERTIFIED ELECTRICAL CONTRACTOR STATEMENT All electrical installations that are preliminary to positioning of the equipment at the site prepared for the equipment shall be performed by licensed electrical contractors In addition electrical feeds into the Power Distribution Unit shall be performed by licensed electrical contractors Other connections between pieces of electrical equipment calibration and testing shall be performed by qualified Medical personnel The products involved and the accompanying electrical installations are highly sophisticated and special engineering competence is required In performing all electrical work on these products GE will use its own specially trained field engineer All of Vendor s electrical work on these products will comply with the requirements of the applicable electrical codes The purchase of equipment shall only utilize qualified personnel i e Vendor s field engineers personnel of third party service companies with equivalent training or licensed electricia
199. rdcopy devices Kodak DuPont Fuji and Konica laser cameras eNTEGRA P amp R Service Manual Direction 2263784 100 5 3 Rev 5 June 17 2001 System Description Hardware Description 5 1 3 Cabling and Linking The cables used with the eNTEGRA system are listed in Table 5 2 The numbers in the table refer to the cable numbers in Figure 5 1 5 1 3 1 Table 5 2 Cables Listing In eae Vendor Part GEMS part FRU Figure 5 1 Description No No Code Length 1 Isolator Transformer Power Supplied with the isolation 1 1 8 m 5 8 ft Cable Transformer 2 Computer Power Cable Supplied with the Computer 1 1 8 m 5 8 ft 3 Monitor Power Cable Supplied with the Monitor 1 1 8 m 5 8 ft 4 VGA Video Cable Supplied with the Monitor 1 1 m 3 3 ft 5 Peripheral SCSI Cable Supplied with DASM LCAM 2 1m 38 3 ft SCSI 1 to SCSI 2 or 1 5 m 4 9 ft Supplied with MFHD DASM LCAM Adapter N A 46 296980G1 1 0 3 M 1ft 6 Cable terminated by 25 pin and 37 pin Connectors Stub Cable 7 DASM Supplied with the N A N A LCAMCommunication Laserprinter Refer to the Cable RS 422 25 pin Laserprinter s service manual 8 DASM LCAM Image Data _ Supplied with the N A N A Cable Laserprinter Refer to the Laserprinter s service manual 9 Modem Cable RS 323 Supplied by with the Modem N A 2 8 m 9 2 ft 10 Modem Power Cable Supplied by with the Modem N A 3 m 9 6 ft 11 Modem Phone Cable Custom
200. restore the previous configuration as follows Click the Config button on the Patient Selector Control Panel Click the Archive tab Click the Restore button In the Restore from dialog click Restore When prompted insert the backup diskette labeled ENTEGRA Configuration Backup into the floppy drive and click OK SI ee a eNTEGRA P amp R Service Manual 8 7 Rev 5 Direction 2263784 100 June 17 2001 Troubleshooting and Repair Troubleshooting 8 2 9 Creating Problem Reports In case of unsolved problems create a problem report as described below and send it to your service office 1 Double click on the Problem Report icon residing on the desktop 2 In the opened Notepad window titled ProbReport txt Notepad type in a description of the problem encountered including the operations that preceded the problem the expected results of these operations and the actual results 3 Pull down the File menu and select the Save entry The program creates a compressed file called ProbReport tar z located in D Einstein 4 Pull down the File menu and select the Exit entry Mail the ProbReport tar z file to your service office ProbReport tar z consists of the following files Your problem report ProbReport txt The error log einstein error log located in D Einstein Einstein_Project exe All the files residing under D Einstein Einstein_User Resources All the files residing under D Einstein Einstein_
201. rinting On Type put snmp2 v1 0B1 tar gz lt Enter gt The system responds 200 PORT command successful 150 Opening BINARY mode data connection for snmp2 v1 0B1 tar gz HAHAHA RHHRHRHRHHH 226 Installing update 0 bytes 0 tape blocks Install NP1600 240 bytes 1 tape blocks Reboot NP1600 40 bytes 1 tape blocks Title NP 1600 40 bytes 1 tape blocks Undo NP1600 247 bytes 1 tape blocks Verify NP1600 11 bytes 1 tape blocks snmp2 tar 642560 bytes 1255 tape blocks x lt x KK XK XK OX 10 The printer reboots eNTEGRA P amp R Service Manual 3 74 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options 3 10 8 5 Image Quality Configuration The image quality parameters for the Codonics are set via a User Preference file that is associated with the eNTEGRA hostname The User Preference file is a text file that contains the parameter name and the setting This file can be created directly on the Codonics or on the eNTEGRA and then sent to the Codonics via the ftp command Table 3 31 provides a summary of the key parameters that can be adjusted Refer to the Codonics Users Manual for details on the effect of each parameter on image quality The procedure for creating the User Preference file on the eNTEGRA and sending it to the Codonics is detailed below Additional information is also provided in the Setting User Preferences chapter of the Codonics Users Manual Table 3 31 Codo
202. rity Values from 1 15 and D produce a positive image polarity white on black Values from 16 30 produce a negative image polarity black on white The film contrast will need to be set on the Lasercamera s input module The following procedure details how to edit the HCdefaults win32 file for Kodak Lasercameras using the notepad editor 1 Move to the Main screen and click the minimize button 2 Double click the ENTEGRA Prompt icon on the desktop and type CD config lt Enter gt 3 Type the following to backup the HCdefaults win32 file copy HCdefaults win32 HCdefaults win32 org lt Enter gt 4 Type the following to open the HCdefaults win32 file using the notepad editor notepad HCdefaults win32 lt Enter gt 5 Type the following notepad command to go to the line containing the ISG3m version parameter lt Ctril gt lt F gt ISG3m version lt Enter gt The cursor will be placed on the I of the following line ISG3m version 3M 6 Press the key until the cursor is over the 3m then overtype by KODAK and press lt Enter gt 7 Type the following line to enter the model type valid model types are KODAK_100XLP KODAK_1120 or KODAK_2180 ISG3m model KODAK_ lt 100XLP or 1120 or 2180 gt eNTEGRA P amp R Service Manual 3 51 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options 8 Type the following notepad command to go to the first line containing the Prn3m
203. rk protocol suite based on the OSI model It allows the eNTEGRA system to communicate over the Starlink network This is now a purchased option for the system Compatibility StarLink is only compatible with Starcam systems running Starlink Version 4 This is a new version of Starlink that was developed specifically to interface Starcam system to eNTEGRA The following systems are compatible Starcam Star 2000 3000 3200 4000 3200i and 40001 Camstar 2000 3200 32001 and 40001 Maxxus Optima 40001 Starcam Star II Build Standard 1 and 2 only M link Version 2 0 from MedImage GE Starlink Agent from Evergreen Technologies O 0 0 0 0 90 StarLink provides the following communication actions over the Starlink network Search fetch and send patient data from Starcam based systems running Starlink Version 4 Receive patient data sent from Starcam based systems running Starlink Version 4 Send patient data to a Starcam based systems running Starlink Version 4 The following are the know compatibility issues and limitations of StarLink for the eNTEGRA system Dueto hardware limitations Starlink Version 4 is not compatible with Build Standard O Starcam systems or Starport systems Therefore these system will not be directly compatible with either the eNTEGRA system or Starcam systems upgraded to Starlink Version 4 A Starport Gateway was developed to address this problem o P Link systems can not send data d
204. roceed to Installing the eNTEGRA Application and Its Accessory Components on page B 17 eNTEGRA P amp R Service Manual 16 Rev 5 Direction 2263784 100 June 17 2001 Installing the eNTEGRA Application and Its Accessory Components B 14 Installing the eNTEGRA Application and Its Accessory Components ON RR i as 10 11 12 13 14 15 16 17 18 19 20 21 Insert the eNTEGRA CD ROM to the CD ROM drive Double click on My computer icon located on the desktop Double click the E drive CD ROM Drive Double click Install vbs Click on OK When prompted insert the licences diskette into the floppy drive attach the Activator onto the parallel port on the back panel of the computer and click OK Click Yes and wait for the installation of the HASP Device Driver Setup program to complete On the Warning window displayed click Yes to continue with the setup program In the HASP Device Driver status dialog click Next In the Setup Option window click Typical In the Confirm Your Selection window click Next When the message The HASP Device Driver has been successfully installed appears click OK Finish In the Acrobat installation click Next Next Select No when asked to reboot From the eNTEGRA CD double click eNTEGRA_LFC vbs In the QGS installation click Next Finish In the Demo Database installation click Next Next Next and then Finish
205. ructure on page 5 10 o Section 5 2 2 License Keys on page 5 12 o Section 5 2 3 Database on page 5 13 o Section 5 2 4 System Accounts on page 5 13 o Section 5 2 5 eNTEGRA Supported Networks on page 5 14 o Section 5 2 6 DICOM on page 5 15 eNTEGRA P amp R Service Manual 5 1 Rev 5 Direction 2263784 100 June 17 2001 System Description Hardware Description 5 1 Hardware Description 5 1 1 System Block Diagram The eNTEGRA Processing amp Review Station is based on a high performance PC a Sony 21 Color Monitor and Accessories such as a Modem and an Erasable Optical Disk EOD The eNTEGRA system supports the DASM and LCAM Digital Lasercam Interfaces and the black white Formatters MFHD and MF96 Only one SCSI hardcopy device either black white formatter or a digital lasercam interface can be attached to the Isolation Transformer Note Figure 5 1 shows the system s block diagram Table 5 7 lists the hardware components Note Only one SCSI hardcopy device can be attached Workstation The cable numbers are used in Monor Table 5 2 Cables Listing PC Display Board isp ay Cable MFHD MF96 SCS _ O SCSI _ ________ Keyboard P DASM LCAM Ja SCS gt 5 Mouse RS232 Modem 6 Adapter Fast Ethernet Optical Disk 9 A Link
206. s The system in whole or in part should not be modified in any way without prior written approval by ELGEMS Ltd No changes additions or removal of any system accessories are permitted without prior written approval of vendor s local service manager Only GE approved optional accessories should be connected Any other equipment may cause damage Installation of any option or peripheral must be completed by a GE service representative eNTEGRA P amp R Service Manual 1 1 Rev 5 Direction 2263784 100 June 17 2001 Safety Guidelines and Regulatory General Safety Guidelines 8 Do not leave the system with problems that may affect the safety of its operation In case you have doubts concerning the system s safe operation call the service office for further instructions and notify the customer that the system is not to be used until the problem is resolved 9 The service engineer must be well acquainted with the Safety and Regulation Chapter of the Operator s Guide 10 Safe servicing requires that the field engineer has a thorough knowledge of all equipment controls and safety devices 11 Care must be taken when handling liquids around the system in the course of maintenance procedures 12 Smoking should be prohibited around the equipment 13 The system should be cleaned regularity to prevent the accumulation of dust and the working area should be well ventilated 14 The maximum allowable ambient temperature is 27
207. s section provides the basic procedure to interface and configure an Imation Lasercamera with eNTEGRA 1 Verify that the DASM LCAM is connected configured properly and the Lasercamera has been added to the eNTEGRA configuration via the Configuration utility refer to Section 3 6 amp Section 3 8 4 11 for details The selected Type in the Printers tab of the ENTEGRA Configura tion window should be 3M The SCSI Device Number of the DASM LCAM can be identified as per Section 3 10 2 3 2 Install and connect the host and image data runs between the Lasercamera s input module and the DASM LCAM Refer to Section 3 10 2 4 3 Configure the Lasercamera s input module the UKEIB and the DEIB for communication with the DASM LCAM Refer to Section 3 10 2 4 4 Power up the systems in the following order to assure proper synchronization Lasercamera UKEIB and DEIB DASM LCAM and then the eNTEGRA 5 Log into eNTEGRA select the Formatter Static image from the Default Patient Calibration study and click the New icon located on the Patient Selector Control Bar Click the Camera tool in the Display Screen Click the Down Arrow in the Film dialog select the Imation lasercamera and click Submit 6 If a No image is printed refer to Section 8 2 for details on troubleshoot ing a An image is printed analyze the image and determine if additional adjustments are required a Adjustments will be made via the HCdefaults win32 file
208. ses c Uncheck the checkbox next to Use IP header compression d Check the checkbox next to Use default gateway on remote net work e Click OK to return to the Server tab dialog Click the Security tab Click the radio button next to Accept any authentication including clear text then click OK to return to the main Dial Up Networking dialog Repeat steps 10 through 18 for each dial up server in the Phonebook entry to dial list When all the dial up servers have been defined click Close to close the Dial Up Networking dialog eNTEGRA P amp R Service Manual 3 24 Rev 5 Direction 2263784 100 June 17 2001 Installation Site Configuration 3 8 4 10 Remote Database 1 Click the eNTEGRA icon on the Task Bar 2 Click the Configuration button on the upper left corner of the Main screen then click Advanced Configuration 3 Click the Database tab 4 Click on the Down Arrow next to the Default database server field and select the Computer Name of the remote server to whose database you want to connect if any 5 If you want to connect to a data base that is not included in the data base options list click the Add button type in the name of the remote server and its IP address and click OK 6 Click the OK button to close the ENTEGRA Configuration window 7 Click Apply to exit the User Preferences window eNTEGRA P amp R Service Manual 3 25 Rev 5 Direction 2263784 100 June 17
209. sh frequency and select 75 Hertz Click the Test button 23 Click OK to display the test screen In the testing Mode window click Yes if you have seen the bitmap properly In the Display Properties window click the OK Proceed to Installing the Sound Driver on page B 9 eNTEGRA P amp R Service Manual 8 Rev 5 Direction 2263784 100 June 17 2001 Installing the Sound Driver B 6 Installing the Sound Driver If necessary insert the eNTEGRA CD ROM to the CD ROM drive Double click the My Computer icon on the Desktop Double click Control Panel Double click Multimedia and click the Devices tab Click Add select Unlisted or Updated Driver and click OK Type in the path to the driver installation files D Utils Audio and click OK where D refers to the CD ROM drive 7 When the Analog Devices SoundComm Driver dialog appears click OK 8 Ifthe Driver Exists window appears click on the New button ON ee a I a 9 Click OK in the Configure Analog Devices SoundComm Window 10 Click No to avoid computer restart and continue to Installing the HP Multimedia Keyboard Utility on page B 9 B 7 Installing the HP Multimedia Keyboard Utility 1 If necessary insert the eNTEGRA CD ROM to the CD ROM drive 2 Using Windows Explorer locate the directory D utils Keyboard where D refers to the CD ROM drive 3 Double click on the Setup icon to initiate the installatio
210. ss as defined in the pre installation checklist b If relevant type in your Subnet Mask c Ifrelevant type in your Default Gateway address as defined in the pre installation checklist If relevant click the DNS tab and type in the DNS IP address defined in the pre installation checklist If relevant click the WINS tab type in the Windows Server primary and secondary IP addresses defined in the pre installation checklist Click OK at the bottom of the page Upon system prompts click Next Next Next and Finish When queried whether to shutdown remove Windows NT CD from the drive and click Yes 41 When prompted press lt Alt gt lt Ctrl gt lt Del gt and login as follows User Name Administrator Password elgems 42 Click OK eNTEGRA P amp R Service Manual 6 Rev 5 Direction 2263784 100 June 17 2001 Installing Windows NT Networking 43 Define the users as follows a Click the Start button on the Task Bar at the bottom of the screen and select Programs Administrative Tools User Manager b Inthe User Manager window click on User in the Menu Bar and select the New User entry Uncheck User Must Change Password at Next Logon Click the checkbox next to Password Never Expires Click the Groups button In the Group Memberships window click Administrators if not already highlighted and then click the lt Add button The Administrators entry moves
211. sses defined in the pre installation checklist and click OK at the bottom of the page Upon system prompts click Next Next Finish Define the users as follows a When prompted press lt Alt gt lt Ctrl gt lt Del gt and login into the system with UserName Administrator Password elgems the password entered at Step 6 above b Inthe opened Welcome window click Close In the Display Properties dialog click Cancel d Click the Start button on the Task Bar at the bottom of the screen and select Programs Administrative Tools User Manager eNTEGRA P amp R Service Manual 5 Rev 5 Direction 2263784 100 June 17 2001 Installing Windows NT Networking al 32 Bae 34 e Inthe User Manager window click on User in the Menu Bar and select the New User entry Uncheck User Must Change Password at Next Logon Click the checkbox next to Password Never Expires Click the Groups button In the Group Memberships window move the Administrators from the Not member list to the Member list by clicking Administrators if not already highlighted and then clicking the lt Add button Click OK The program reverts to the User Manager window k Enter Username entegra Password entegra Confirm Password entegra 1 Click OK again m Close the User Manager window pa m p o T Click the Start button on the Task Bar at the bottom of the screen and
212. stalling a US Robotics Modem 1 In the Install New Modem dialog select U S Robotics Inc from the Manufacturers column 2 Select your modem from the Models list Courier V Everything External Courier V 34 Data Fax Modem etc 3 Click on Next and proceed to Step 14 b Installing a Motorola modem 1 In the Install New Modem dialog select Motorola Ger from the Manufacturers column 2 Select your modem from the Models list Motorola Codex 3265FAST etc 3 Click on Next and proceed to Step 14 c Installing the Multitech Modem 1 Insert the ENTEGRA application CD into the CD ROM drive 2 In the Install New Modem dialog click on Have Disk eNTEGRA P amp R Service Manual 6 16 Rev 5 Direction 2263784 100 June 17 2001 Software Installation Software Load From Cold For Dell OptiPlex GX200 14 3 Type G Drivers Multitech Where G is the CD ROM drive and Click OK 4 Select MultiTech Systems MT5634ZBA and click Next Select the port your modem is connected to COM1 if your modem is con nected to Com1 Serial A or COM2 if your modem is connected to Com2 Serial B 15 Click on Next The system will now install your selected modem 16 Click Finish in the Install New Modem window 17 Click OK 18 Click Comfigure 19 Select Dial out and receive calls and click OK 20 Click Comtinue in the Remote Access Setup 21 Click OK twice 22 Click Close 23 Click Yes to re
213. stalling the eNTEGRA Application and Its Accessory Components C 13 Installing the eNTEGRA Application and Its Accessory Components ON RR i as 10 11 12 13 14 15 16 17 18 19 20 21 Insert the eNTEGRA CD ROM to the CD ROM drive Double click on My computer icon located on the desktop Double click the E drive CD ROM Drive Double click Install vbs Click on OK When prompted insert the licences diskette into the floppy drive attach the Activator onto the parallel port on the back panel of the computer and click OK Click Yes and wait for the installation of the HASP Device Driver Setup program to complete On the Warning window displayed click Yes to continue with the setup program In the HASP Device Driver status dialog click Next In the Setup Option window click Typical In the Confirm Your Selection window click Next When the message The HASP Device Driver has been successfully installed appears click OK Finish In the Acrobat installation click Next Next Select No when asked to reboot From the eNTEGRA CD double click eNTEGRA_LFC vbs In the QGS installation click Next Finish In the Demo Database installation click Next Next Next and then Finish In the eNTEGRA Application installation click Next Next Next When asked click the radio button next to the applicable language then click Next Next If requ
214. start the system 24 Remove the Windows NT CD from the drive 25 Proceed to Installing the FTP Service on page 6 18 eNTEGRA P amp R Service Manual 6 17 Rev 5 Direction 2263784 100 June 17 2001 Software Installation Software Load From Cold For Dell OptiPlex GX200 6 2 13 Installing the FTP Service 1 2 Insert the Windows NT CD into the CD drive Right click the Network Neighborhood icon on the desktop and select Properties to display the Network dialog 3 Click the Service tab and click the Add button 10 11 12 13 14 15 16 17 18 19 From the opened Select Network Service list select Microsoft Peer Web Server and click OK In the Installed from input field enter D i386 where D is your CD drive and click OK On the opened Microsoft Peer Web Services Setup dialog click OK In the opened Options list deselect all options except FTP Service and Internet Service Manager then click OK Click Yes to create the prompted directory In the FTP Publishing Directories input field type C Insite and click OK If required acknowledge by clicking Yes to create the Insite directory When the installation has been complete successfully click OK Click Close in the Network dialog Click Start on the task bar and select Programs Microsoft Peer Web Services Internet Service Manager Double click the Computer Name entry to open the FTP Service pr
215. stem Options on page 6 13 6 2 10 Setting System Options Set the following operating system configurations in the given order 1 2 3 4 5 When done proceed to Installing Internet Explorer 5 on page 6 15 Setting the Date Format on page 6 13 Setting the Application Event Viewer Loggings on page 6 14 Setting the Task Bar Properties on page 6 14 Setting the View Options on page 6 14 6 2 10 1 Setting the Date Format 1 Click left on the Start icon on the Tasks Bar and select Setting gt Control Panel On the Control Panel window double click on the Regional Settings icon 3 Click on the Date tab Click the down arrow at the Short data style field select the format M d yyyy and click OK eNTEGRA P amp R Service Manual 6 13 Rev 5 Direction 2263784 100 June 17 2001 Software Installation Software Load From Cold For Dell OptiPlex GX200 6 2 10 2 Setting the Application Event Viewer Loggings 1 Click left on the Start icon on the Tasks Bar and select Programs Administrative Tools common Event Viewer 2 Click the Log option in the Menu Bar and select the Application entry 3 Click the Log option in the Menu Bar and select the Log settings entry 4 In the Event Log Settings window check the Overwrite Events as Needed field Logs 5 Click OK 6 Close the Event Viewer window 6 2 10 3 Setting the Task Bar Properties 1 Click right on an empty place of the Task Bar and s
216. tallation Hardcopy Options 3 10 7 4 Image Quality Configuration Note The image quality parameters for the Helios are set via the HCdefaults win32 file on eNTEGRA The HCdefaults win32 file is a text file that contains the default print device parameters for all hardcopy devices supported by the eNTEGRA hardcopy server It is located in the D einstein einstein_project resources directory Typically the HCdefaults win32 file contains a section for each print device s parameters Figure 3 16 lists the Helios settings in the HCdefaults win32 file Table 3 28 provides a summary of the parameters that can be adjusted Refer to the Helios Service Manual for details on the effect of each parameter on image quality The basic procedure for editing the HCdefaults win32 file along with an example can be found in Section 3 10 2 5 Table 3 28 Helios Print Device Parameters Parameter Description petaurt p Setting PrnHelios curve This parameter defines the gamma curve the Helios uses to produce the 17 image Range is 0 to 40 PrnHelios brightness This parameter adjusts brightness of the image on the film Range is 16 to 16 1 PrnHelios contrast This parameter adjusts contrast of the image on the film Range is 16 to 16 1 PrnHelios dmin This parameter sets the lower density value 0 02 PrnHelios dmax This parameter sets the upper density value 2 01 PrnHelios margin These two parameter s
217. tems on the ApexNet Host names and IP Addresses of any remote DICOM stations Host name and IP Addresses of any remote eNTEGRA systems for remote database Host name and IP Addresses of any network hardcopy device Helios Codonics etc Host name IP address and phone number for any system to be connected via modem eNTEGRA P amp R Service Manual Direction 2263784 100 3 14 Rev 5 June 17 2001 Installation Site Configuration 3 8 3 Procedure Overview Table 3 9 Configuration And Licensing Overview Time Steps Min Reference Before changing the configuration of 1 Section 3 12 an existing system back up the old configuration Changing Institution ID 1 Section 3 8 4 1 Changing the Default Computer name 1 Section 3 8 4 2 Updating the Regional Settings 1 Section 3 8 4 3 Changing Default Host Name 1 Section 3 8 4 4 StarLink and APexNet Configuration 1 Section 3 8 4 5 DICOM Configuration 1 Section 3 8 4 6 Interfile Configuration 1 Section 3 8 4 7 Remote Access Configuration 1 Section 3 8 4 8 Modem Configuration 1 Section 3 8 4 9 Remote Database 1 Section 3 8 4 10 Hardcopy Configuration 25 Section 3 8 4 11 Backup of new configuration 1 Section 3 12 Total 39 40 eNTEGRA P amp R Service Manual 3 15 Rev 5 Direction 2263784 100 June 17 2001 Installation Site Configuration 3 8 4 System Configuration Procedure 3 8 4 1 Changing Institution ID
218. ter gt e While the Ist partition is highlighted press lt Enter gt to install Windows NT on drive C Install Windows NT as follows a In the opened dialog use the lt gt key to highlight the line Format using NTFS and press lt Enter gt Drive C will be formatted It may take several minutes b When prompted press lt Enter gt twice to start copying the NT files c Upon system prompt remove the Windows NT CD d When prompted press lt Enter gt to reboot After reboot the installation continues followed by another automatic reboot When prompted insert the NT installation CD into the CD drive and click OK Proceed to Installing Windows NT Networking on page B 4 eNTEGRA P amp R Service Manual 3 Rev 5 Direction 2263784 100 June 17 2001 Installing Windows NT Networking B 3 Installing Windows NT Networking Note 1 In the Windows NT Setup window click Next to continue 2 Inthe opened Setup Options window select Typical and click Next 3 In the opened Name and Organization window type in your site_name and organization_name and click Next 4 Inthe Registration window type in your product_ID recorded on the provided manual and click Next 5 When prompted type in your computer name as defined in the pre installation checklist and click Next 6 When prompted type in your password as defined in the pre installation checklist the following description wi
219. terface the 25 pin RS422 line into their input module The DASM LCAM also sends the high resolution digital image data over a 37 pin 8 bit parallel RS485 interface to the input module Section 3 10 6 2 provides the basic procedure for interfacing configuring the Konica Lasercameras to ENTEGRA Section 3 10 6 3 provides details on interfacing the Konica Lasercameras to the eNTEGRA Section 3 10 6 4 provides details on configuring the eNTEGRA and the Lasercamera for optimal image quality eNTEGRA P amp R Service Manual 3 62 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options 3 10 6 2 Basic Procedure This section provides the basic procedure to interface and configure a Konica Lasercamera with eNTEGRA 1 Verify that the DASM LCAM is connected configured properly the SCSI Device Driver has been initialized the permission for the SCSI Device Driver are set properly and the Lasercamera has been added to the eNTEGRA configuration refer to Section 3 6 and Section 3 8 for details The Device Type should have been set to SG3m in the Printers tab in the Config utility Install and connect the host and image data runs between the Konica s input module and the DASM LCAM This should be done by the Konica service engineer Refer to Section 3 10 6 3 Configure Konica s input module for communication with the DASM LCAM This should be done by the Konica service engineer Refer to Section
220. the film density level The range is from Prn3m 952 density 1 to 16 In HCdefaults win32 a setting of D causes the Lasercamera to use the setting on the input module Boarder Specifies the boarder level 0 is dark and 255 is Prn38m 952 bdr clear Stage Time Out Specifies the delay between staging and Prn3m stage timeout exercising an image Note In most cases the contrast and density will be set using the input module Refer to the Imation 3M Service Manual or Service Representative for details If the needs to be updated refer to the HCdefaults win32 section below The stage time out needs to be set to 20 for the main interface a HCdefaults win32 The HCdefaults win32 file is a text file that contains the default print device parameters for all hardcopy devices supported by the eNTEGRA hardcopy server It is located in the D Einstein einstein_project resources directory Typically the HCdefaults win32 file contains a section for each print device s parameters The parameters for the 952 compatible Lasercameras start with Prn3m 952 are shown in Figure 3 5 Figure 3 6 Figure 3 7 Figure 3 8 Figure 3 9 and Figure 3 10 below eNTEGRA P amp R Service Manual 3 40 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options protocol 952 Prn3m 952 bdr 0 lq ____ _Edit to change Border Prn3m 952 interface Prn3m 952 cmd timeout Lca
221. tion 3 10 4 1 Overview Note This section provides details on how to connect the DuPont Sterling Lasercameras to the eNTEGRA system and how to configure both the eNTEGRA and Lasercamera to produce good quality films The eNTEGRA hardcopy server sends commands and high resolution digital image data to the DASM LCAM over the SCSI 2 bus using the Analogic DASM SCSI command set The DASM LCAM converts these commands into the 952 commands and a digital image The DuPont has only been validated using the DASM LCAM interface The 952 commands host control are sent from the DASM LCAM s 25 pin female RS422 port to the 37 pin RS422 host communication port on the DuPont Linx Q interface which is referred to as the SID Since the RS422 interface on the SID is a 37 pin male connector a 25 pin male to 37 pin female cable is required 46 296980G1 can be used The DASM LCAM also sends the high resolution digital image data over a 3 pin 8 bit parallel RS485 interface to DuPont SID Section 3 10 4 2 provides the basic procedure for interfacing configuring the DuPont Lasercameras to ENTEGRA Section 3 10 4 3 provides details on interfacing the DuPont lasercameras to the eNTEGRA Section 3 10 4 4 provides details on configuring the eNTEGRA and the Lasercamera for optimal image quality eNTEGRA P amp R Service Manual 3 54 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options 3 10 4 2 B
222. tion 10 Failures during installation 84 Service incurred because of loss or damage in shipment and filing claims 87 Service training on site field office Education Center 91 Costs incurred when modifying products to make them compliant with local country regulatory standards 94 Sales activity Service work performed on behalf of sales includes equipment demonstrations and sales assistance 98 F M 1 work Network installation time should be covered by a K1000 catalog number or 06 Money It should not be charged directly to the eNTEGRA installation eNTEGRA P amp R Service Manual 3 3 Rev 5 Direction 2263784 100 June 17 2001 Installation Overview 3 1 4 Installation Flow Chart Site Preparation Complete v Isolation Yes Transformer p Isolation transformer Installation Section 3 3 No ja PC Installation Section 3 4 v Peripheral Yes Tower Peripheral Tower Installation Section 3 5 No h DASM LCAM Yes Option No q DASM LCAM Installation Section 3 6 v Initial Power up and Login Section 3 7 v Site Configuration Section 3 8 v Connect Network Section 3 9 v Upgrade to Starlink Ver 4 Section 3 9 4 v Hardcopy Yes Option No lt 4 Hardcopy Interface Section 3 10 v InSite Entitlement Section 3 11 v Backup Section 3 12
223. tion Hardware Description 5 1 4 Sony EOD 5 1 4 1 Jumpers Setting Before installing the Sony EOD verify the following jumper settings see the Jumpers Block located on the EOD rear panel each Jumper consists of two pins Figure 5 2 e SCSI ID 1 3 from the three jumper pairs used to set the SCSI ID the left most pair should be jumpered while the two other pairs should be empty e Termination 11 Jumpered if the EOD is the last device on the SCSI chain Empty if the EOD is not the last device on the SCSI chain DC Power SCSI ID SCSI Connector Connector 0000000600600000000000000 0000000000000000000000000 Figure 5 2 Sony EOD Rear Panel eNTEGRA P amp R Service Manual 5 7 Rev 5 Direction 2263784 100 June 17 2001 System Description Hardware Description 5 1 4 2 DIP Switch Setting Before installing the Sony EOD ensure that all DIP Switch settings are OFF Rear EOD Panel lt 1 8 S501 1 8 S502 A Front EOD Panel Figure 5 3 Sony EOD DIP Switches eNTEGRA P amp R Service Manual 5 8 Rev 5 Direction 2263784 100 June 17 2001 System Description Hardware Description 5 1 5 DASM LCAM The DASM LCAM is an intelligent device that interfaces a 3M laser camera to a SCSI bus The stand alone DASM LCAM unit attaches to the workstation SCSI bus and emulates a SCSI disk drive in both function and form The LCAM takes high level commands sent from the workst
224. to 952 commands and a digital image Due to image quality issues the DASM VDB interface is no longer being offered The 952 commands host control are sent from the DASM LCAM s 25 pin female RS422 port to a UKEIB Universal Keyboard External Interface Box and then to the Lasercamera s input module The UKEIB converts the RS422 signals to a Fiber Optic signal which is then sent to the Lasercamera s input module Since the RS422 keypad interface on the UKEIB is a 37 pin male connector a 25 pin male to 37 pin female cable is required 46 296980G1 can be used The DASM LCAM sends the high resolution digital image data over a 37 pin 8 bit parallel RS485 interface to a DEIB Digital External Interface Box and then to the Lasercamera s input module The DEIB converts the RS485 signals to a Fiber Optic signal which is then sent to the Lasercamera s input module Section 3 10 2 2 provides the basic procedure for interfacing configuring the Imation Lasercameras to eNTEGRA Section 3 10 2 3 provides details for finding the SCSI Device Number of the DASM LCAM Section 3 10 2 4 provides details on interfacing the Imation lasercameras to the eNTEGRA Section 3 10 2 5 provides details on configuring the eNTEGRA and the Lasercamera for optimal image quality eNTEGRA P amp R Service Manual 3 34 Rev 5 Direction 2263784 100 June 17 2001 Installation Hardcopy Options 3 10 2 2 Basic Procedure Thi
225. ts as stated in EN60601 1 2 for immunity Class 1 The operating conditions are eNTEGRA P amp R Service Manual Direction 2263784 100 1 6 Rev 5 June 17 2001 Safety Guidelines and Regulatory Regulatory Information classified on the basis of performance criteria as defined in IEC 801 2 Do not use devices which intentionally transmit RF signals cellular phones transceivers or radio controlled products in the vicinity of this equipment as it may cause performance outside the published specifications Keep the power to these types of devices turned off when near this equipment The medical staff in charge of this equipment is required to instruct technicians patients and other people who may be around this equipment to fully comply with the above requirement Unauthorized change or modifications of the equipment could void the user s authority to operate the equipment 1 7 2 CE Conformity This product conforms with the requirements of council directive 93 42 EEC concerning Class ITA medical devices and therefore bears the CE mark of conformity The name and address of the CE representative appears on the back of the front page of this manual 1 7 3 USA Regulations e The system was cleared for sale in the USA by the FDA e Caution Federal US law restricts this device for sale by or on the order of a physician e Inthe USA this system should only be used with FDA approved radiopharmaceuticals eNTEGRA
226. yle to be used the options shown are those that are relevant to the selected language country combination Click the OK button and close the Control Panel window Note These settings affect the date shown in the Patient Selector and also the date ote formats which are accepted by the patient selector filter mechanism 3 8 4 4 Updating Setting the IP Address 1 6 Click on the minimize button on the Main Screen Header to view the system s Desktop Right click the Network Neighborhood icon located on the Desktop and select the Properties entry In the Protocol tab highlight TCP IP Protocol and click the Properties button Change the IP address to address assigned in the pre installation checklist If relevant update also the Subnet Mask and Default Gateway Click the OK button Click the OK button again Impb rtant You must enter in a valid and unique IP Address Using the default address will p cause network problems The system also needs a valid IP Address for DICOM Remote Database network printing and InSite to work correctly eNTEGRA P amp R Service Manual 3 17 Rev 5 Direction 2263784 100 June 17 2001 Installation Site Configuration 3 8 4 5 StarLink and ApexNet Configuration applicable only if the OSI option is installed 1 Ee A Ne es Click the Configuration button on the upper left corner of the Main screen then click Advanced Configuration