1. If the Safety Burst Disc requires service start by contacting Air America for a proper replacement disc Using another disc assembly could result in harm to the Guardian and or individuals Begin by removing the safety jam nut with a 3 16 inch Allen key exposing the orifice washer and ruptured disc assembly Turn the tester over to allow the disc and washer to fall out If they do not come out easily take a pick and CAREFULLY pry them out CAUTION DO NOT DAMAGE OR SCORE THE BOTTOM OF THE SAFETY POCKET Damage to the bottom of the safety pocket will result in an improper seal and premature failure of the new safety burst disc Prior to installing your new safety burst disc orifice washer and jam nut it is best to clean the tester body Take a cotton swab and dip the end into some alcohol now wipe the inside of the tester body and thread area Repeat this process until the cotton swab comes out clean this may take several applications Caution Be sure not leave any cotton residue in the tester Install the burst disc covered by the orifice washer The orifice washer should be placed rounded side up for best results IMPORTANT NOTE Do not replace the orifice washer with ANYTHING other than an Air America orifice washer The dimensions have been specifically calculated After the bust disc and washer are in place install the hex head jam nut and torque to 15 20 ft lbs to complete the procedure Page 3 of 4 Guardian Trouble Shooting
2. times by rotating the rotary bleed valve counterclockwise it is NOT necessary to rotate the valve more than a quarter turn purging any trapped air in the regulator passages and allowing the system pressure to stabilize You can also utilize this procedure to simulate firing the marker thereby judging the response time of your air system After cycling the Guardian several times take note of the gauge reading if you feel that adjustments are needed to the output pressure of the primary regulator do so and cycle the system again to stabilize the pressure Repeat this procedure until you reach the desired output pressure of the primary regulator being tested CAUTION BEFORE DISCONNECTING AND REMOVING THE GUARDIAN BE SURE THAT THE SYSTEM HAS BEEN TURNED OFF AND THE ROTARY BLEED VALVE IS OPEN This shut down procedure will allow any trapped pressure in the system to escape and enable a safe removal of the primary regulator Testing secondary regulators The Air America Guardian is designed to allow easy adjustment of secondary regulators Most secondary regulators are equipped with a standard ASA male fitting on one end Testing a regulator with this type of fitting requires you to simply screw the regulator into the female ASA port on the Guardian If your secondary Page 2 of 4 regulator requires a different configuration use the Air America ASA adapter and fittings supplied with your Guardian to attach the output port of the regu
3. 2240 Elmhurst Road Elk Grove Village IL 60007 USA 847 545 9999 Fax 847 545 0275 www airamerica com Guardian Universal Regulator Tester Service Manual Congratulations on your purchase of the Air America Guardian Universal Regulator Tester Precision machined and anodized from certified quality aerospace aluminum alloy your Guardian Universal Regulator Tester is an indispensable field or bench tool specifically designed to provide a fast fail safe accurate way to tune your Air Nitrogen delivery and regulation systems tm Introduction The Air America Limited Lifetime Warranty guarantees a lifetime of trouble free service and accuracy while providing the highest safety and equipment standards in the sport of Paintball Guardian Standard features include Low pressure safety to prevent over pressurization of the system Rotational bleed valve that will allow you to cycle your system Marker discharge simulation 180 degree sweep gauge for accurate pressure readings Exterior knurling to allow one had operation Skirted knob to direct air flow during the bleed phase Internationally famous Air America Limited Lifetime Warranty SAFETY ALERT ALWAYS DE GAS YOUR SYSTEM BEFORE YOU ATTEMPT ANY SERVICE OR REPAIR NOTE To achieve maximum benefit from your factory replacement parts have them installed by an authorized AIR AMERICA technician Additional technical assistance is available through the internet at www airameric
4. Guide Note The following chart is for reference purposes only Air America recommends that all safety precautions as outlined in the Service Manual are strictly adhered to before any repairs or testing procedures are attempted In the event repairs are required certified Air America technicians using factory replacement parts should be relied upon to achieve maximum performance from your system Additional technical assistance is available at www airamerica com Bleed Valve Position Gauge Action Possible Cause Probable System Repair Closed Steady No Leaks Normal Normal Cycled 1 16 To 1 4 Drops Slightly amp Normal Normal Turn Rapidly Returns To Preset Pressure amp Holds Steady Closed Reads Zero System Obstruction Remove Obstruction amp Clean Regulator Regulator Adjustment Nut Out Turn On System Of Adjustment Improperly Set Adjust Regulator Output Pressure Closed Slowly Rises Faulty Pin Seat Replace With Factory Replacement Parts Creeps Past Set Pressure Dirt Debris In Regulator Clean Regulator Cycled 1 16 To 1 4 Turn Pressure Drops Then Slowly Climbs Back To Preset Pressure Non Air America Regulator Seat amp Pin Wrong Piston O Ring Wrong Spring Pack Improper Piston Spring Pack Lubricant Defective Spring Pack Dirt Debris In Regulator Replace With Air America Seat amp Pin Replace With Air America O ring Replace With Air America Spring Pack Clean Assemblies
5. a com Page of 4 Terminology Take the time and use the following exploded view of the Air America Guardian Universal Regulator tester to familiarize yourself with the names and locations of the parts you will be working with Doing so will make the instructions for use clearer and enable you to be more proficient in your testing procedures Safety Orifice Washer Seat lt Safety Burst Disk ASA O Ring Orifice Washer Safety Burst Disk Regulator Valve Pin i Male Q Disconnect i Jam Hex Nut Main Body ASA Adapter Using the Air America Guardian To test primary regulators Install the Air America ASA Adapter supplied with your Guardian tester into the female port located on the bottom of the Guardian Using a combination of hose and fittings to match your current air delivery system connect the output side of your air system to the ASA Adapter on the Guardian NOTE to prevent premature bleed off of the systems tank pressure the Rotary Bleed Valve on the Guardian must be in a HAND TIGHT fully closed clockwise position Once the primary regulator is connected to the Guardian you may then pressurize the system The gauge on the Guardian will read output system pressure pressure going into the marker or secondary regulator NOTE Before you make any adjustments to the output pressure of your primary regulator cycle the Guardian several
6. amp Relubicate With Proper Lubricant Replace Spring Pack Clean Regulator Closed Steady Beyond Bad Seat amp Pin Replace Seat amp Pin Preset Pressure Wrong Piston O Ring Replace With Air America O ring System Leaks Piston Binding In Housing Free Bind amp Clean Assembly Replace O Ring amp Out Of Regulator Dirt In Regulator Lubricate Nut Until Tank Regulator Set To High Clean Regulator Reaches Reset Output Pressure To Lower Pressure Approximately 1200 PSI Safety Functioning Properly Ignore Leak Closed Steady System Defective O Ring Replace With Air America O ring Leaks Out Piston Safety Failure Replace Piston Assembly Regulator Nit Cycled 1 16 To 1 4 Drops amp Stays Internal Obstruction To Remove Obstruction amp Clean Regulator Turn Low Regulator Replace With Air America Seat amp Pin Non Air America Regulator Seat amp Pin Dirt Debris In Regulator Clean Regulator ALL RIGHTS RESERVED AIR AMERICA INC 20 Page 4 of 4
7. de faces up insert the 1 4 inch Allen key in the jam nut Remove the jam nut followed by the Stainless Steel Orifice Washer Once these parts are removed the Regulator Seat should fall out if not gently press it out from the Bleed Valve side with the 3 16 inch Allen key Prior to installing your new Regulator Seat and Valve Pin it is best to clean the housing Take a cotton swab and dip the end into some alcohol now wipe the inside of the Tester body and Bleed Valve Repeat this process until the cotton swab comes out clean this may take several applications Caution Be sure not leave any cotton residue in the tester To install the new Regulator Seat and Valve Pin start by inserting the Regulator Seat narrow side first then install the Stainless Steel Orifice Washer smooth side facing the seat Use the 1 4 inch Allen key to install and sufficiently tighten the jam nut to prevent a Regulator Seat leak NOTE Regulator Seats have a taper to them with one side being wider than the other Rotate the Main Body till the ASA adapter portion is facing down Now insert the Valve Pin long narrow end first into the bore for the Rotary Bleed Valve BEFORE installing the Bleed Valve use a cotton swab to put a small amount of Anti seize lubricant onto the valves thread area and onto the pin bore located at the bottom of the Bleed Valve Now install the Rotary Bleed Valve by screwing it in clockwise do not worry about the pin assembly it s self centering
8. lator to the inlet side of your Guardian Once the proper ASA connections are made and your secondary regulator is connected to the Guardian you may then pressurize the system follow the same procedures as outlined for the testing of the primary regulator NOTE to prevent premature bleed off of the systems tank pressure the Rotary Bleed Valve on the Guardian must be in a HAND TIGHT fully closed clockwise position Servicing the Air America Guardian The Air America Guardian has been engineered for a lifetime reliable service If service is ever required Air America will service your tester upon request If you choose to do the repairs yourself the following procedures and safeguards should be utilized The Guardian has been designed to use many of the standard Air America replacement parts currently available in the Air America parts kits The standard Air America Regulator Seat and Valve Pin Assembly are located in the main body of the tester These are the only service replacement parts you will need to bring your Guardian back to like new condition The Guardian can be completely disassembled with the following tools 3 16 inch Allen key and a 1 4 inch Allen key Start the disassembly by removing the Rotary Bleed Valve from the tester entirely Turning the tester over will allow the Valve Pin assembly to fall out of the tester body Once Valve Pin assembly has been remove rotate the tester so that the ASA si

Download Pdf Manuals

image

Related Search

Guardian guardian guardian dental guardian anytime guardians of the galaxy guardian uk guardian news guardian life guardian insurance guardian browser guardian ad litem guardian bikes guardians vs rangers guardian dental provider portal guardians of the galaxy 3 guardian vision guardian dental provider login guardian life insurance guardians score guardians schedule guardian browser download guardian dental insurance guardian newspaper uk guardian tales guardian credit union guardian druid