Home
Característica Técnica Série H
Contents
1. 200 400 Controller e Computer as master e Computer as master V2 e Computer as slave e DELTA DVP ES SS EP EH PLC e Delta VFD B Inverter e Dupline DKG2 e ERO TFS THS LFS e Facon FB Series RS232 RS485 e Facon FB Series RS232 RTS e FAMA DMC SC 500 Series e Fama softPLC e Festo FPC FEC Series e FUJI 5000 G11S P11S e Fuji Micrex F e Fuji NB Series e GE Series 90 CCM e GE Series 90 SNP e Hitachi EC Series e Hitachi EH2 Series e Hitachi H EH1 Series ATEN O HUST CNC Controller Idec Micro 3 Jetter DELTA Jetter NANO 8 Jetter process PLC Keyence KV Series Klockner Moeller PS316 Klockner Moeller PS4 201 Koyo Direct DL Series Koyo K sequence LG GLOFA GM6 LG K10 60H 200H LG K200S LG K300S LG Master K108 305 608 100S Matsushita FP Series Mirle Axis Controller SD CC Mirle DX Controller Mitsubishi AOJ2 CPU Port Mitsubishi A1N CPU Port Mitsubishi A1S A2S CPU Port Mitsubishi AZA AZAS CPU Port Mitsubishi ASN A1SH CPU Port Mitsubishi AnA U Link Mitsubishi AnN S Link Mitsubishi Fregrol A500 Series Mitsubishi FX Series Mitsubishi FX 10GM 20GM Mitsubishi FX2N Mitsubishi FX2N with 485ADP Mitsubishi MELSEC Q CPU Mitsubishi MELSEC QnA LINK ModBus Master ModBus Slave ModBus ASCII Master ModBus ASCII Master V2 ModBus ASCII Slave Modicon 984 RTU Master Simatic S7 300 via MPI port Simatic S7 300 via PC adapter Taian N2 Series Inverter Taian TPO1 Series Taian TPO2 Series T
2. ser usadas de forma animada mostrando diferentes estados Execu o de l gica no terminal Sim programadas por MACRO ou LADDER Comunica o Multi Canal Permite o uso de um driver diferente em cada porta de comunica o dispon vel Aplica es Multi ldiomas Sim at 5 idiomas por aplica o Caracteres especiais Sim permite acentua o e caracteres UNICODE Tipos e tamanhos de caracteres Suporta qualquer fonte do sistema operacional Windows At 16 fontes diferentes podem ser usadas em cada aplica o Prote o de aplica o poss vel proteger a aplica o por senha impedindo que pessoas n o autorizadas tenham acesso para upload Possui fun es para monitora o e registro de alarmes Caracter sticas do Software de Programa o H Designer H 2700 Plataforma PC com sistema operacional Windows 9x Me 2000 ou XP Espa o necess rio em disco 60 Mb Mem ria RAM necess ria 64 Mb ou mais V deo 256 cores e resolu o de 800 x 600 ou superior idioma nais Altus S A 5 Caracter stica T cnica S rie H C d Doc CT106861 Drivers de Comunica o Revis o B Est o dispon veis mais de 100 drivers de comunica o incluindo protocolos padr o de mercado e propriet rios A lista de drivers est em constante atualiza o e AB DH 485 e AB IQ Master e AB MicroLogix 1000 1500 e AB PLC 5 e AB SLC5 03 5 04 e ABB COMLI Slave mode Binary e ASCII Device e A TECH SD
3. terminais de opera o H K30 COM2 com CPs da S rie Quark usando QK 1402 AL 1743 Este cabo possui um conector serial RJ45 padr o Altus e outro DB25 Macho RS 232C Pode ser utilizado para e Interliga o dos terminais de opera o H T60 COM2 com CPs da S rie Ponto COM3 e Interliga o dos terminais de opera o H T60 COM2 com CPs da S rie Grano AL 1744 e PO8525 O cabo AL 1744 permite a liga o por RS 485 entre o terminal de opera o com conector DB25 e o derivador e termina o de rede PO8525 A liga o feita pela COM2 nos modelos H T60 Para constituir a rede RS 485 podem ser usados os cabos AL 2306 ou AL 2301 Para instru es completas sobre a montagem da rede e o uso das termina es consulte a CT do PO8525 CT109825 ATEN O A comunica o com CPs Altus feita utilizando o protocolo MODBUS RTU O terminal de opera o pode ser configurado como Mestre ou Escravo A liga o deve ser feita em uma porta do CP que tenha esta capacidade Consulte a documenta o do CP para maiores informa es Para informa es sobre a conex o com equipamentos de outros fabricantes consulte o cap tulo de instala o Altus S A 3 Caracter stica T cnica S rie H C d Doc CT106861 Revis o B Caracteristicas HK3oms HTOOBP H T60C P HTO0CN H K30M S 3 Teclado H T60B P 5 7 Touch H T60C P 5 7 Touch H T60C N 5 7 Touch Cores da tela 16 tons de cinza 16 tons de azul Brilho da
4. Caracter stica T cnica S rie H Do O C d Doc CT106861 Revis o B Descri o do Produto A S rie H composta por terminais de opera o com um conjunto de caracter sticas adequado para maioria das aplica es Possui desde pequenos terminais at modelos coloridos e com touch screen E uma escolha racional para aplica es que necessitem de grande funcionalidade S o destinados ao controle de m quinas e processos possuindo grande flexibilidade de uso Todos os modelos s o programados com o software H Designer de forma visual e poderosa em ambiente Windows As fotos ilustram alguns dos modelos dispon veis Tem como principais caracter sticas eTela colorida de at 5 7 com touch screen einterfaces de comunica o RS 232 RS 485 e RS 422 einterface Ethernet eDrivers de comunica o padr o de mercado e espec ficos para equipamentos de diversos fabricantes ePrograma o gr fica eRel gio Tempo Real eExecu o de macros e l gica em ladder eGr ficos animados eGr ficos de tend ncia eBiblioteca de s mbolos eSimula o da aplica o na ferramenta de programa o Compat vel com UCPs Altus com suporte a MODBUS RTU Algumas caracter sticas est o dispon veis apenas em alguns modelos Consulte o restante do documento para detalhes Dados para Compra itens Integrantes A embalagem do produto cont m os seguintes itens e Terminal de opera o e4 Elementos de fixa o em painel eConector de al
5. PRX Dos GND refer ncia 6 RS485 RS 422TX gt 8 RS2320TS_ _ D 9 R5422PRX Revis o B Caracter stica T cnica S rie H C d Doc CT106861 Revis o B Modelos H T60 COM 1 COM 2 oo a as o o g o o o D Cs DH r Ha Pino Fun o 1 RS485 2 rsosnx 3 RS2327X_ ES 5 OND refer ncia 6 E EM RS 232 CTS Sa da de 5 Vdc 100 mA Pino Fun o Pino Fun o a po ma rsassarasaerx 2 RS 2327x_ 15 RS485 RS 4227x 3 RS232RX_ 16 RS422PX a Rs232RTS 17 RS422PX 5 rs22cTs s o o B 7 OND refer ncia Do o Sa da de 5 Vdc 100 mA owo o RSARRTS O uno m Jrsaznrso Due eos s p o 13 rsa22crs doo d Montagem Mec nica Consulte o manual de utiliza o correspondente para informa es sobre a instala o mec nica Altus S A 8 Caracter stica T cnica S rie H EDDIE C d Doc CT106861 Revis o B Dimens es F sicas Dimens es em mm Modelo H K30 CUTOUT DIMENSION 160 8 UNIT mm 1600 m Uai JiUUUUt NNDD E RR da 14 AA aaa 92 5 r y Si malko m aa e CUNANNNNNND Modelos H T60 Unit mm 185 8 0 5 46 6 135 8 0 5 O f2s48 TSS CUTOUT DIMENSION Le Le Le E Altus S A 9 Caracter stica T cnica S rie H ED C d Doc CT106861 Revis o B Programa o Os terminais de opera o da S rie H s o programados em ambient
6. e Windows com a ferramenta de programa o H Designer H 2700 O ambiente possui interface gr fica facilitando o uso de todas as fun es Possui uma biblioteca que auxilia O usu rio na utiliza o de textos gr ficos e estat sticas A fun o de Screen Manager permite uma vis o global do projeto facilitando o desenvolvimento e visualiza o dos resultados A ferramenta possui simulador que permite verificar os resultados sem necessidade de terminal de opera o ou comunica o com controlador Possui facilidades para projeto usando tags como importa o e exporta o de listas e refer ncia cruzada A mesma ferramenta utilizada para todos os terminais da S rie H Este software n o acompanha o terminal de opera o sendo fornecido separadamente File Edit View Screen Draw Object Library Application Tool Options LadderPlus window Help 000 a Fle H xo o BitTeste nalogTemp w40005 TUTTI TO E Ro ER ER ED A TUE CEEE UR ECO Manuais Para maiores detalhes t cnicos configura o instala o e programa o dos produtos da S rie H os seguintes documentos devem ser consultados C digo do Documento MU299047 Manual de Utiliza o H K30 MU299046 Manual de Utiliza o H T60 MU399004 Manual de Programa o S rie H Altus S A 10
7. ea DB9 F mea Porta de comunica o RS 232 RS 485 RS 232 RS 485 RS 232 RS 485 RS 232 RS 485 serial 2 COM2 RS 422 RS 422 RS 422 RS 422 DB9 F mea DB25 F mea DB25 F mea DB25 F mea Porta multifuncional gerem po SM l Porta Ethernet Ethernet 173x 105 5x56mm 195x145x60mm 195x145x60mm 195x145x60 mm 160 8 x 93 3 mm 185 8 x 135 8 mm 185 8 x 135 8 mm 185 8 x 135 8 mm painel Tens o de imEnta o 24 Vdc 15 24 24Vdc 15 15 24 24Vdc 15 15 24 24Vdc 15 15 Prote o do frontal IP65 IP65 IP65 IP65 Altus S A 4 Caracter stica T cnica S rie H C d Doc CT106861 Revis o B Temperatura de 0 C a50 C 0 C a50 C O Cabo C 0 C a50 C opera o Temperatura de 20 C a 70 C 20 C a 70 C 20 C a 70 C 20 C a 70 C armazenagem Umidade do ar 20 a 90 n o 20 a 90 n o 20 a 90 n o 20 a 90 n o ambiente condensado condensado condensado condensado Peso SOO 0 65 Kg 0 81 Kg 0 81 Kg 0 81 Kg Notas Mem ria Flash ROM O valor mostrado corresponde mem ria total sendo usada para armazenagem do programa executivo e da aplica o do usu rio Porta Multifuncional Pode ser usada para conex o de impressora usando cabo adaptador incluso na embalagem Caracter sticas de Software Todos os modelos Importa o de figuras Bitmaps JPEG GIF e arquivos AutoCAD bmp jpg gif dwg dxf Figuras animadas As figuras importadas podem
8. exmate 320 TI 325 330 Series TI 435 Series TI 500 505 Series Ti505 for BroadW eb Toshiba M20 M40 Toshiba T1 T2 Unidriver UD 70 Vigor M VB Series VIPA Sys200V MPI YASKAWA NS600 Yokogawa FA M3 Series Para programa o e conex o a produtos Altus est o dispon veis cabos conforme se o de Itens Relacionados Para conex o em equipamentos de outros fabricantes disponibilizada a pinagem dos conectores do terminal para que sejam feitos os cabos de comunica o necess rios A pinagem do equipamento ao qual deseja se ligar o terminal de opera o deve ser conhecida Instala o Instala o El trica Para garantir o funcionamento adequado do terminal de opera o e evitar emiss o de r dio frequ ncia a instala o do aterramento obrigat ria A instala o el trica feita pela liga o da alimenta o de 24 Vdc e pela conex o ao controlador Consulte o manual de utiliza o correspondente para maiores informa es sobre a instala o el trica Altus S A Caracter stica T cnica S rie H C d Doc CT106861 Pinagem das Portas de Comunica o CUIDADO Liga es erradas podem causar danos n o cobertos pela garantia dos equipamentos Modelos H K30 Altus S A rd E FP E oS0totolo 7 K y y E j j fr y AN e i AN 9 O 8 AO T 6 j N S j 14 KA o H N Pino Fun o 1 RS485 RS 422TX 2 RS232PX_ o 3 RS232TX o 4 RSA22
9. imenta o eGuia de Instala o da S rie H eCabo para liga o de impressora apenas modelos H T60B P H T60C P e H T60C N Altus S A 1 Caracter stica T cnica S rie H C d Doc CT106861 Revis o B C digo do Produto Os seguintes c digos devem ser usado para compra do produto C digo Terminal de Opera o H K30M S 3 Teclado H T60B P Terminal de Opera o H T60B P 5 7 Touch H T60C P Terminal de Opera o H T60C P 5 7 Touch H T60C N Terminal de Opera o H T60C N 5 7 Touch H 2700 Programador H Designer Produtos Relacionados para Aquisi o Obrigat ria Os seguintes produtos devem ser adquiridos separadamente para possibilitar a utiliza o do produto AL 1739 Cabo Programa o RS232 CFDB9 CMDB9 Notas AL 1739 Este cabo necess rio para a programa o dos terminais da S rie H por RS 232C com o software H Designer H 2700 Possui um conector DB9 F mea para conex o em PC e um DB9 Macho para conex o ao terminal de opera o Faz a programa o atrav s da porta de comunica o COM2 nos modelos H K30 e atrav s da COM1 nos modelos H T60 Produtos Relacionados Os seguintes produtos devem ser adquiridos separadamente quando necess rio ET POBS2S AL 2306 Cabo para Rede RS 485 AL 2301 Cabo RS 485 para Redes ALNET I e ALNET II Notas AL 1740 Este cabo possui um conector serial RJ45 padr o Altus e outro DB9 Macho RS 232C Pode ser utilizado para e Interliga o dos terminai
10. s de opera o H T60 COM1 com CPs da S rie Ponto COMB e Interliga o dos terminais de opera o H T60 COM1 com CPs da S rie Grano e Interliga o dos terminais de opera o H K30 COM2 com CPs da S rie Ponto COMB e Interliga o dos terminais de opera o H K30 COM2 com CPs da S rie Grano AL 1741 e PO8525 O cabo AL 1741 permite a liga o por RS 485 entre o terminal de opera o com conector DB9 e o derivador e termina o de rede PO8525 A liga o feita pela COM1 nos modelos H T60 e pela COM2 nos modelos H K30 Para constituir a rede RS 485 podem ser usados os cabos AL 2306 ou AL 2301 Para instru es completas sobre a montagem da rede e o uso das termina es consulte a CT do PO8525 CT109825 AL 1742 Este cabo possui um conector serial DB9 Macho padr o IBM PC e outro DB9 Macho RS 232 C Este cabo utilizado como adaptador E utilizado em conjunto com os cabos destinados a interligar as diferentes interfaces dos CPs a computadores IBM PC Altus S A 2 Caracter stica T cnica S rie H C d Doc CT106861 Revis o B AL 1742 e AL 1342 Estes dois cabos utilizados juntos permitem e Interliga o dos terminais de opera o H T60 COM1 com CPs da S rie AL 2000 usando AL 2005 e Interliga o dos terminais de opera o H T60 COM1 com CPs da S rie Quark usando QK 1402 e Interliga o dos terminais de opera o H K30 COM2 com CPs da S rie AL 2000 usando AL 2005 e Interliga o dos
11. tela 36 cd m 110 cd m 300 cd m 300 cd m Ajuste de contraste Por potenci metro Pela tela touch screen Pela tela touch screen Pela tela touch screen ou potenci metro ou potenci metro ou potenci metro Tipo de ilumina o da LED CCFT CCFT CCFT tela Tempo de vida m dio 50000 horas 50000 horas 75000 horas 75000 horas da ilumina o RISC 32 bits RISC 32 bits RISC 32 bits RISC 32 bits LEDs de indica o MR e porta a e portas Fones e portas ie e portas de comunica o de comunica o de comunica o de comunica o Tela sens vel ao toque Sim anal gica Sim anal gica Sim anal gica Touch screen Teclas 16 teclas incluindo 6 teclas uma de 6 teclas uma de 6 teclas uma de teclado num rico acesso a menu e 5 de acesso a menu e 5 de acesso a menu e 5 de fun o fun o fun o Tempo de vida das Maior que 500 000 Maior que 1 000 000 Maior que 1 000 000 Maior que 1 000 000 teclas acionamentos de acionamentos de acionamentos de acionamentos Mem ria Flash ROM 4 Mbytes 4 Mbytes 4 Mbytes 4 Mbytes Mem ria RAM 128 Kbytes 512 Kbytes 512 Kbytes 512 Kbytes Mem ria para dados e 512 Kbytes 512 Kbytes 512 Kbytes receitas Rel gio tempo real Sim com bateria de Sim com bateria de Sim com bateria de Sim com bateria de L tio substitu vel L tio substitu vel L tio substitu vel L tio substitu vel Porta de comunica o RS 232 RS 485 RS 232 RS 485 RS 232 RS 485 serial 1 COM1 DB9 F mea DB9 F m
Download Pdf Manuals
Related Search
Related Contents
Petzl PIXA 2 CLUB3D Radeon R7 250 AMD Radeon R7 250 2GB Toshiba 80GB SATA HDD Manual de usuario - Tango: H Philips FWM15 User's Manual TDSHーBA 東芝蛍光灯皿具取扱説明書 保管用 新表示ルール AC10MS user manual.cdr 注意 注意 8.スペースの確保 9.取扱説明書への明記 Copyright © All rights reserved.
Failed to retrieve file