Home

Hudson Valley Lighting, Inc. P.O. Box 7459 106 Pierces Road

image

Contents

1. controlling the circuit 2 Ifan existing fixture is being replaced remove it and note to which of the wires in the outlet box the fixture was attached DO NOT SEPARATE ANY OTHER WIRES THAT MAY BE IN THE BOX DO NOT DAMAGE THE INSULATION OF OLDER WIRING In regular circumstances the BLACK wire will be the Hot lead and the WHITE wire will be the Neutral or Common lead A GREEN or BARE COPPER wire is the Ground In older buildings it is always good practice to reconfirm the polarity of the wiring 3 This fixture is designed to be mounted on a standard round or octagon box The box must be securely mounted to the structure of the building FIXTURE INSTALLATION 1 Remove the fixture and parts bag s from the carton Before discarding the carton double check packing to make certain that all parts are found 2 Remove the setscrews which holding the mounting plate to the fixture 3 Pull the wires in the outlet box through the center hole of the mounting plate Attach the plate to the outlet box Align the mounting plate so the top screw hole is exactly at the top The green ground screw should face out 4 Fasten the fixture ground wire to the green or bare copper wire in the box or fasten it to the mounting bracket with green screw provided NEVER FASTEN THE GROUND WIRE TO THE BLACK OR HOT WIRE FAILURE TO FOLLOW THIS INSTRUCTION COULD RESULT IN SERIOUS INJURY OR DEATH 5 Fasten the white fixture wire to the white wi
2. ingressou como na etapa 5 7 Coloque a fixa o sobre a placa de montagem e prenda o no lugar com os setscrews removidos na etapa 2 8 Coloque o vidro do soquete e usar chave de fenda para trav lo com anel de soquete 9 Instale a luz l mpadas Nota Este acess rio avaliado para um tipo de 75 watts T XENON n o tungst nio hal genas G9 l mpada de base N O SUPERIOR A POT NCIA RECOMENDADA 10 Restaure a energia ao circuito no disjuntor ou fus vel caixa
3. VALLEY e LIGHTING stannar HUDSON rench i Socket Ring Glass Mounting Plate Cre Ground Screw Electric Tape a Approved Fastener Hudson Valley Lighting Inc P O Box 7459 106 Pierces Road Newburgh NY 12550 800 814 3993 www hudsonvalleylighting com INSTALLATION INSTRUCTIONS 2661 2662 2663 2664 2665 GENERAL 1 To insure the success of the fixture installation the following instructions and diagram s should be read and understood 2 All electrical connections must be made in accordance with the National Electric code and local codes and ordinances If you are uncertain of the methods of installing electrical wiring and lighting fixtures secure the services of a qualified licensed electrician 3 TOOLS NEEDED Blade screwdriver slip joint pliers wire cutter stripper electrical current tester stepladder and electrical tape NOTE The important safeguards and instructions outlined on this sheet are not meant to cover all possible conditions and situations that may occur It must be understood that common sense caution and care are factors that cannot be built into any product Caution and care must be supplied by the person s installing operating and maintaining this lighting fixture INSTALLATION PREPARATION 1 TURN OFF THE ENTIRE ELECTRICAL CIRCUIT TO WHICH THE LIGHTING FIXTURE IS TO BE ATTACHED Move the appropriate circuit breaker to the off position or completely remove the fuse
4. re in the outlet box Fasten the wires to together with an approved fastener wire nut Starting about 1 below the fastener tightly wrap connection with electrical tape so that the tape seals the end of the fastener Make sure that there is no exposed wire or strands that could cause a dangerous short circuit 6 Connect the black fixture wires to the black wire in the outlet box Fasten the joined wires as in step 5 7 Place the fixture over the mounting plate and fasten it in place with the setscrews removed in step 2 8 Place the glass onto the socket and use wrench to lock it with socket ring 9 Install the lamp light bulbs NOTE This fixture is rated for a 75 watt type T XENON Not Tungsten Halogen G9 base lamp DO NOT EXCEED RECOMMENDED WATTAGE 10 Restore power to circuit at breaker or fuse box VALLEY LIGHTING sranvas HUDSON Chave Inglesa Placa de fixa o Caixa de sa da Vidro Parafuso Parafuso Fixador Aprovado Hudson Valley Lighting Inc P O Box 7459 106 Pierces Road Newburgh NY 12550 800 814 3993 www hudsonvalleylighting com INSTALLATION INSTRUCTIONS 2661 2662 2663 2664 2665 Portugu s GERAL 1 1 Para garantir o sucesso da instala o do dispositivo el trico as seguintes instru es e diagrama s devem ser leu e compreendeu 2 2 Todas as liga es el ctricas devem ser feitas em conformidade com o c digo nacional el ctrico e c digos locais e ordenan a
5. s Se voc n o tiver certeza de m todos de instala o el tricos fia o e lumin rias de ilumina o acesso aos servi os de um eletricista licenciado 3 Ferramentas PRECISAVA Blade chave de fenda alicates conjunta de deslizamento fio cortador stripper verificador atual el trico escada e fita isolante Nota As salvaguardas importantes e instru es descritas nesta planilha n o se destinam a cobrir todas as condi es e situa es que podem ocorrer Deve ser entendido que o senso comum cuidado e cuidados s o fatores que n o podem ser criados em qualquer produto Cautela e cuidados devem ser fornecidos pela pessoa ou pessoas a instala o opera o e manuten o deste aparelho de ilumina o PREPARA O PARA INSTALA O 1 DESLIGUE O CIRCUITO EL TRICO DE TODO PARA A QUAL O APARELHO DE ILUMINA O DEVE SER ANEXADO Mover o disjuntor apropriado para o fora de posi o ou remover completamente o fus vel controlando o circuito 2 Se um dispositivo el trico existente est sendo substitu do remova e nota que os fios na caixa de sa da o acess rio foi anexado N O SEPARE OUTROS FIOS QUE PODEM SER EM CAIXA N O DANIFICA O ISOLAMENTO DE CABOS MAIS VELHOS Em circunst ncias normais o fio preto ser a lideran a Quente e o fio branco vai ser Neutro ou Comum chumbo Um fio verde ou cobre nua o terreno Em edif cios mais antigos sempre boa pr tica de reconfirmar a polaridade de fia o 3 Este di
6. spositivo el trico projetado para ser montado em uma caixa redonda ou octagon padr o A caixa deve ser montada com seguran a para a estrutura do edif cio INSTALA O DE DISPOSITIVO EL TRICO 1 Remova o dispositivo el trico e partes substituida a embalagem Antes de descartar a embalagem dupla verifica o de embalagem para certificar se de que todas as pe as s o encontradas 2 Retire os setscrews que segurando a placa de montagem para a fixa o 3 Puxe os fios na caixa de sa da atrav s do orif cio central da placa de montagem Anexe a chapa para a caixa de sa da Alinhe a placa de montagem para que o buraco de parafuso superior exatamente na parte superior O parafuso terra verde deve enfrentar fora 4 Prenda o fio de terra de fixa o para o verde ou cobre nua banc ria na caixa ou apert lo para o suporte de montagem com parafuso verde fornecido NUNCA PRENDA O FIO DE TERRA PARA O PRETO OU FIO QUENTE N O SEGUIR ESTA INSTRU O PODE RESULTAR EM LES O GRAVE OU MORTE 5 Prenda o fio branco acess rio para o fio branco na caixa de sa da Prenda os fios para juntamente com um fixador aprovado porca de fio A cerca de 1 abaixo o fixador firmemente quebra conex o com fita isolante para que a fita sela o fim do fixador Certifique se de que n o h fios expostos ou vertentes que poderiam causar um curto circuito perigoso 6 Conecte os fios preto acess rio para o fio preto na caixa de sa da Prenda os fios

Download Pdf Manuals

image

Related Search

Related Contents

GUÍA PARA LA EVALUACIÓN DEL TEMA LIBRE  orion starBlast™  Utilisation du navigateur Web (suite)  INSTALLATION / OWNER`S MANUAL  OPERATION MANUAL  Conditions générales  Operating Instructions Transmitter Power Supply Unit SINEAX B 812  3G Mobile Router (RUT100) User Manual  BitsyXb User`s Manual  User Manual - Embedded Communications Systems  