Home
uso manutenzione EBV
Contents
1. USO E MANUTENZIONE ACCUMULATORI Serie EBV MESSA IN FUNZIONE PUT ON DLIVERY FORNITURA CONDITION ON DELIVERY Gli accumulatori sono forniti The accumulators are delivered _sia precaricati con azoto ad una pressione di _ either pre charged with nitrogen to a storage pressu stoccaggio di 5 bar re of greater than 3 bar _ Sla precaricati con azoto al valore di pressione _ or gharged with notrogen a pressure corresponding corrispon dente a quella calcolata in funzione tothe pressure calculated according to its working delle condizioni di Impiego characyeristics MESSA IN FUNZIONE PRESSURIZING WITH NITROGEN _Effettuare o controllare la precarica al valore Use the OLAER charging and gauge assembly to determinato dal calcolo impiegando il verificato check the charging pressure against the calculated re gonfiatore OLAER La pressione di precarica pressure and adjust if necessary The charging pres deve essere tassativamente inferiore alla pres sure must be less than sione di bollo impressa sul corpo _the calculated pressure S stamped on the shell If Nel caso la pressione risulti inferiore a 1 5 bar the charging pressure read on the gauge is less than necessario seguire la procedura di rigonfiag 1 5 bar follow the bladder recharging procedure see gio della sacca vedi capitolo di rimontaggio al the reassembly point punto U e seguenti _Check the charging valve for leacks using soapy _Verificare la tenuta stagna della valvola azoto w
2. ater for exemple ad esempio con saponata _Thigten the protective cap manually _ Chiudere il tappo di protezione a mano _Periodic checking of inflation pressure _ Verifica periodica della pressione di gonfiaggio Use the tester and pressurizer to check the initial per mezzo del verificatore gonfiatore verificare inflation pressure on startup prima di mettere in esercizio che la pressione Repeat this operation during the first week of opera di precarica abbia il valore richiesto Ripetere tion and then every six months during normal wor l operazione durante la prima settimana di fun king or every month during intensive working zionamento e in seguito almeno ogni 6 mesi Important nel caso di normale utilizzo ogni mese se l uti it is essential to use dry nitrogen from a bottle equip lizzo gravoso o continuativo ped with a pressure reducing valve The use of an air Importante compressor and of oxygen is strictly forbidden E indispensabile utilizzare azoto secco in bom INSTALLATION bola munita di riduttore L impiego di compres For maximum efficiency the accumulator should be sori d aria o ossigeno assolutamente vietato placed as close as possible to the system on which it INSTALLAZIONE is used Allow a free space of 200 mm around the Per ottenere il miglio rendimento l accumulatore charging valve to install the OLAER charging and gau deve essere posizionato il pi vicino possibile allo ge assembly see data sheet utiliz
3. c solvent Visually check the condition of the installed components Clean the bladder with isopropyl alhohol for exemple Check that the surface of the bladder is not demaged Check that there is no corrosion inside the accumulator shell If the inside of the accumulator shell is protected check the condition of the protection Replace all aprts consedered defective The O Rings must be replaced Pagina 2 USO E MANUTENZIONE ACCUMULATORI Serie EBV SMONTAGGIO ACCUMULATORE DISMANTIG ACCUMULATORS USO E MANUTENZIONE ACCUMULATORI Serie EBV RIMONTAGGIO DELL ACCUMULATORE J Eliminare laria contenuta nella sacca compri mendola foto 12 K Lubrificare abbondantemente interno del corpo dellaccumulatore con lo stesso fluido utilizzato nel circuito o similare circa 10 del volume dell accumulatore fino cpacita di 5 It 5 per capacit superiori ruotandolo pi volte attorno all asse foto 13 In caso di fluidi a bassa viscosit inferiore a 5 cSt consultare OLAER L Lubrificare la sacca ed introdurla nel corpo Controllare che non sia ripiegata o attorciglia ta Per accumulatori di grande capacit utiliz zare l apposito attrezzo tira sacca foto 14 M Rimontare la targhetta e riavvitare la ghiera senza bloccarla N Introdurre nel corpo la valvola a reticella finch non sia ben posizionata foto 15 O Rimettere in posizione l anello elastico ponendo la massima attenzione al suo co
4. e a zero la pressione del circuito idraulico Smontare l accu mulatore e sistemarlo in posizione orizzontale in una morsa o altro sistema di fissaggio proteggen do il corpo al fine di non danneggiarlo A Svitare il tappo di protezione della valvola azoto foto 1 B Svitare il tappo della valvola azoto foto 2 C Scaricare mediante il verificatore gonfiatore il gas contenuto nella sacca lentamente finch il manometro non segna pressione 0 foto 3 Assicurarsi che la sacca non abbia pi press lone Importante se cio non accade e la sacca conti nua a mantener e chiusa la valvola contattare OLAER D Svitare la valvola azoto completa foto 4 o le parii interne del sistemavalvola foto 5 6 o la valvola a spillo foto 7 a seconda dei modelli E Svitare la ghiera di bloccaggio della sacca e la targhetta foto 8 a seconda dei modelli F Togliere la vite di spurgo e relativa guarnizio ne se esistenti G Estrarre l anello elestico foto 9 H Estrarre la valvola a reticella foto 10 Estrarre la sacca sfilandola attraverso lo stes so foro lato reticella avendo la massima cura per non danneggiarla foto 11 PULIZIA E ISPEZIONE Ripulire scrupolosamente le parti metalliche con un solvente organico Verificare visivamente lo stato dei pezzi montati Pulire la sacca con alcool isopropilico ad esem pio Verificare che la sacca non presenti diffetti visibili Verificare che il corpo non presenti
5. inter namente tracce di corrosione Se il corpo ha in ternamente un rivestimento protettivo verificarne il buono stato Sostituire le parti difettose Gli O Ring debbono essere sempre sostituiti DISMANTIG OF ACCUMULATORS Isolate and depressurize the accumulator using the isolating block or depressurize the hydraulic system Remove the accumulator and place it horizontally in a vice or another securing device Protect the shell so as not to demage it A Unscrew the guard cap from the charging valve photo 1 B Unscrew the charging valve plug photo 2 C Discharge the gas contained in the bladder using a charging and gauge assembly untill O is show on the manometer photo 3 Make sure that the bladder is not charged with nitrogen by checking that it is not in contact with the grid Important if the bladder remains in contact with the grid consult OLAER D remove the single piece charging valve photo 4 or the charging valve mechanism photo 5 6 or the valve core photo 7 according to the model E Remove the lock nut from the charging valve body and then the name plate photo 8 F remove the hydraulic vent screw and its seal if required G Remove the spring ring photo 9 H Remove the grid photo 10 Remove the bladder through the fluid port ope ning taking care not to demage it photo 11 CLEANING AND INSPECTION Carefully clean all the metallic parts of the accumu lator with an organi
6. itable tool a bladder extractor photo 14 M Reinstall the name plate and the lock nut Do not tighten the lock nut N Insert the grid into this accumulator shell until it reaches its stop Photo15 O Reinstall the spring ring taking care to position it correctly in its groove photo 16 P Install the venting screw and its gasket if required Q Secure the valve shell nit position using the cor rect horizontal bars and tighten it phto 17 R Install the single piece charging valve tighten ing it to a torque of 1 5 mdaN photo 18 or the charging valve mechanism photo 19 20 or the valve body tightening it to a torque of 0 029 mdaN photo 21 S Before charging the accumulator with nitrogen turn the accumulator shell around its axis to lu bricate its inner wall evenly T For reasons of safety it is mandatory to install a connection unit on the liquid side photo 22 Immediately after this operation charge the bladder with nitrogen to a pressure of 1 to 1 5 bar with the accumulator in the orizontal posi tion see table charging process U Install the blanking plug or the connector on the liquid side photo 23 V screw the guard cap from the charging valve photo 24 Pagina 4 USO E MANUTENZIONE ACCUMULATORI Serie EBV RIMONTAGGIO ACCUMULATORE REASSEMBLY ACCUMULATORS
7. rretto posizio namento nell apposita scanalatura foto 16 P Se previsto rimontare lo spurgo con relativa guarnizione Q Bloccare la ghiera della sacca mantenendo ferma quest ultima tramite chiave sui piatti foto 17 R Avvitare la valvola azoto completa con coppia di serraggio di 1 5 mdaN foto 18 o le parti in terne del sistema valvola foto 19 20 o la val vola a spillo con coppia 0 029 mdaN foto 21 S prima di gonfiare con l azoto far ruotare l ac cumulatore attorno al suo asse per ottenere una perfetta lubrificazione di tutta la sua su perficie interna T Tassativamente per ragioni di sicurezza avvitare un raccordo o flangia nella bocca lato impianto foto 22 Immediatamente dopo provocare l espansione della sacca con una pressione d azoto da 1 a 1 5 bar foto 23 U Avvitare Il tappo di protezione della valvola azo to foto 24 DISMANTIG OF ACCUMULATORS L Squeeze the bladder to discharge the air from it photo 12 M Lubricate the inside of the shell copiously by turning it around its axis Use either the medium used in the circuit or a similar liquid to approx 10 of the accumulator volume for capacities up to 5 litres or 5 for higher capacities photo 13 If the luquid is low in viscosity lower than 5 cSt consult OLAER L Lubricate the bladder and insert into the accu mulator shell Check that the bladder is not fol ded or tw isted For large capacity accumulators use a su
8. zatore E importante lasciare uno spazio li The hydropneumatic accumulators may be installed in bero di 200 mm intorno alla valvola di gonfiaggio any position from horizontal to vertical charging valve azoto per il montaggio del verificatore gonfiatore on the top The name plate must be visible and the vedi foglio illustrativo venting srew accessible Gli accumulatori possono essere installati dalla The accumulators are connected by means of the tap posizione verticale valvola azoto in alto all oriz ped or threaded port or an SAE CETOP flange The zontale Lasciare visibile la targhetta e accessibi connector may be equipped with a reducer fitting a le lo spurgo Il collegamento si effettua tramite lo flange or a counter flange attacco filettato o la flangia SAE o CETOP secon do i modelli L accumulatore pu essere fornito HYDRAULIC PRESSURIZING con raccordo di riduzione flangia o contro flan Ven the piperwork of any air that it might contain by gla carefully loosening the vent screw according to the MESSA IN FUNZIONE model until the liquid begins to flow and then close Spurgare laria eventualmente presente nelle the vent tubazioni A questo scopo allentare la vite di spurgo con precauzione sino alla fuoriuscita di liquido limpido e serrare poi accuratamente Pagina USO E MANUTENZIONE ACCUMULATORI Serie EBV SMONTAGGIO DELL ACCUMULATORE ce e decomprimere laccumulatore tramite il blocco d intercettazione DI o metter