MANUALE D`USO E MANUTENZIONE

image

Contents

1. Solid state relay 1 ev UP ical 2 O lo C H I O 4 N 13 14 15 0 DEMOLITION 15 1 OPERATOR QUALIFICATION Qualified operators are all those who have read and understood all contents included in chapter SAFETY on page 2 and in chapter DEMOLITION on page 14 15 2 DEACTIVATION AND DEMOLITION Once the instrument has reached the end of its technical and operative life it must be deactivated Deactivation and demolition must be carried out in a manner that allows raw materials that compose the instrument to be recycled for other purposes Deactivation and demolition of the instrument must be carried out in a safe way ATTENTION FALC INSTRUMENTS declines any liability for any damages to people animals or objects resulting from recycling single parts of the instrument for functions or assembly situations which are different from the original ones 15 3 DEACTIVATION AND DEMOLITION PROCEDURE Deactivation and demolition operations must be performed exclusively by properly trained and equipped personnel m Turn off the instrument m Disconnect the power supply m Disassemble the following parts Electrical parts Plastic components Resin support feet m In case the instrument has to be moved please refer to chapters INSTALLATION AND USE PROCEDURES on page 5 and TRANSPORT AND STORAGE on page 8 ATTENTION The instrument is made with non biodegradable materials The instrument is consider
2. revisione manuale 1 3 3 manual revision 1 3 3
3. Portare in posizione l interruttore generale IG Ruotare la manopola del timer sul tempo desiderato display si accende e lo strumento inizia a scaldare 4 FASE DI SET Premendo il tasto O compare 1l valore del SET POINT Se per quattro secondi non si preme alcun tasto 1l display torna ad indicare la temperatura corrente Utilizzare il tasto O per impostare 11 valore di temperatura desiderato memorizzare il valore di temperatura impostato premere 1l tasto Lo strumento torna a mostrare la temperatura corrente nella camera Ruotare la manopola 3 per regolare la velocita della ventola solo STF F In posizione centrale sotto al display presente un indicatore di scostamento tre LED verde al centro rossi 1 due laterali C1 sono cinque possibili segnalazioni 4 gt Latemperatura inferiore di 1 5 C dal SET POINT 4 gt La temperatura entro 1 0 C dal SET POINT Latemperatura 0 5 C dal SET POINT nm gt La temperatura entro 1 0 C dal SET POINT P gt Latemperatura maggiore di 1 5 C dal SET POINT 5 14 5 PROCEDURA DI ARRESTO DELLO STRUMENTO Portare in posizione O l interruttore generale IG Togliere dallo strumento 1 contenitori ATTENZIONE gt movimentazione di oggetti caldi Sezionare lo strumento dalla linea di alimentazione NOTA Se per qualunque motivo si costretti ad interrompere un trattamento p
4. acciaio verniciato a forno con polvere epossidica antiacida S2Lt 80Lt SOLt 120Lt 800x650x850 900x750x800 720 2091 92 720 2091 93 Carrello porta stufe in lamiera d acciaio verniciato a forno con polvere epossidica antiacida con ruote 4150 girevoli e con freno Tavolo porta A In profilato di alluminio anodizzato e 240Lt 400Lt ripiano in alluminio anodizzato 1000x800x 500 S2Lt 80Lt SOLt 120Lt 800x650x850 900x750x800 720 2091 98 720 2091 95 720 2091 96 Neoteo pei 7 14 10 0 MANUTENZIONE 10 1 MANUTENZIONE DELLO STRUMENTO Eseguire le operazioni di manutenzione con lo strumento spento e scollegato dalla rete di alimentazione Assicurarsi che lo strumento sia freddo prima di iniziare qualsiasi operazione Far eseguire la manutenzione solo da personale specializzato addestrato e abilitato all uso alla preparazione e alla manutenzione dopo aver letto attentamente e recepito le raccomandazioni e le istruzioni fornite in questa sezione 10 1 1 MANUTENZIONE ORDINARIA Rientrano nella manutenzione ordinaria tutte quelle operazioni che possono essere eseguite dall utilizzatore S1 tratta di operazioni di pulizia di ispezione periodiche e preventive che consentono l utilizzo in sicurezza dello strumento 10 1 2 MANUTENZIONE PROGRAMMATA Rientrano nella manutenzione programmata tutte quelle operazioni che possono essere eseguite solo dal personale autorizzato Si tratta di ispezioni periodiche preventi
5. c valutazione rischi Oltre alle dimensioni di ingombro dello strumento necessario rispettare le seguenti condizioni n prossimit della zona di collocazione devono essere predisposte le fonti di alimentazione Prevedere uno spazio sufficiente ed in piano per il normale utilizzo e manutenzione dello strumento compreso lo spazio per le eventuali apparecchiature periferiche In oltre lo strumento deve essere collocato in un locale coperto e protetto dal contatto con gli agenti atmosferici Per svolgere in sicurezza le fasi di lavorazione e di manutenzione dello strumento necessaria una buona illuminazione Una normale illuminazione ambiente permette di lavorare senza rischi dovuti a zone d ombra La temperatura ammessa per un normale funzionamento va da un minimo di 5 C ad un massimo di 40 C con umidit relativa massima 80 per temperature sino a 31 C con diminuzione lineare sino al 50 alla temperatura di 40 C 2 Prima di connettere lo strumento alla linea di rete controllare 1 dati per il voltaggio 5 20 MESSA IN FUNZIONE 1 ALLACCIAMENTI ELETTRICI Lo strumento ha un unico punto di alimentazione elettrica esterna posto sul retro 2 AVVIAMENTO DI PROVA Prima di procedere all utilizzo ordinario e continuativo dello strumento verificare il perfetto funzionamento eseguendo almeno un ciclo completo di prova 3 ACCENSIONE DELLO STRUMENTO Inserire la spina del cavo di alimentazione nella presa di rete 220 240V 50 60Hz
6. 2 0 PRELIMINARY OPERATIONS 2 1 VERIFICATION OF TRANSPORT DAMAGES Carefully unpack the instrument from the shipping container and perform a visual inspection in order to check its conditions Any deformation of visible parts of the instrument indicates that it has suffered damage during transportation that could compromise normal working Please pay particular attention to the conditions of the following parts of the instrument nstrument structure Controls and warning lights Make sure all screws and bolts are tightened properly 1 14 2 2 IN CASE OF DAMAGE Damages due to transport must be attributed to the carrier and immediately communicated to the manufacturer or his representative Send a claim letter to the carrier 2 3 CLEANING THE INSTRUMENT Get rid of any external dust or dirt that may have accumulated during transport 3 0 INSTRUMENT CHARACTERISTICS COMMON CHARACTERISTICS _ E 2 3 N 7 imam on pet si _ cl dimensions Wat mm 0500 I _ eie Jar o tea e is imm in peste ke O imm ssi OO EY Weight was calculated distributing it uniformly over the shelf lenght e Steel structure painted in oven with antacid epoxy dust Internal chamber made of INOX steel e Door with double locking system e 45mm backside hole for smoke discharge or cables passage e 10mm upper side hole for thermometer
7. av rant d fectueuses en raison de d fauts de fabrication manifest s L appareil devra parvenir franco notre usine accompagn si possible d un bref descriptif du d faut relev et si les d fauts sont reconnus comme tels sera et exp di nos frais La garantie exclut par ailleurs toutes les pieces particuli res sujettes une usure normale pi ces chauffantes par exemple La garantie d cline toute responsabilit pour un appareil ayant subi des modifications des alt rations ou encore des r parations effectu es par des personnes non autoris FALC INSTRUMENTS s r l OBJECTO GARANTIA Por garantia entendemos la pura y simple sostituzion durante un per odo limitado de 24 meses a partir da la fecha de entrega de las partes defectousas a causa de problemas de fabricaci n El aparato deber ser devuelto a nuestra f brica ex factory posiblemente con una explicaci n incluida Y el problema ser verificado el aparato ser reparado y enviado por nosotros y los gastos del transporte correr n a nuestro cargo La garantia no ser v lida si al controlar el aparato comprobamos que el mismo ha sido danado o ha sido reparado por personas no autorizadas a reparar el mismo FALC INSTRUMENTS s r l SUBJECT GUARANTY For a period of 24 months from the date of delivery to the carrier With the word guaranty we engage ourselves to substitute any and every faulty instrument product compone
8. insertion e PID microprocessor based temperature control Timer can be set from 0 to 12 hours with possibility to set it to infinite time e Incubators are provided with a second glass door which allows users to inspect the internal chamber without causing any thermal imbalances 2 14 FORCED VENTILATION OVENS from ambient 5 to 300 Accuracy NATURAL VENTILATION OVENS Model STF N 5214 STF N 80Lt STF N 120Lt STF N 24014 STF N 400Lt C orking temperature from ambient 5 to 300 Accuracy 300 C 3 0 3 0 29 9 259 5 4 0 1200 1400 1600 2600 3400 720 2080 05 720 2080 08 720 2080 12 720 2080 24 720 2080 40 INCUBATORS icrsza ICTFSOLI criz craon orking temperature from ambient 5 to 80 350 720 2070 16 720 2070 18 720 2070 20 720 2070 22 SUPPLEMENTARY GRATING SHELVES SPARE PARTS 720 2091 05 720 2091 08 720 2091 12 720 2091 24 720 2091 40 3 14 4 0 CONTROLS Regulates the quantity of air passing through the back flue Display Shows current or set temperature Turns on when resistances are working or during the setting phase Turns on when temperature is equal to the set temperature Turns on when temperature is higher than the set temperature Turns on during the setting phase or when temperature is 2 C or 5 C higher than the set point temperature Confirms that changes are made Pa Increases the set temperature D Turns on when tem
9. interno della camera disporre il a E aa materiale in modo da lasciare un po di spazio tra l uno e l altro ed evitare di occludere la presa per la circolazione d aria 6 14 8 0 USI PREVISTI E NON PREVISTI USI PREVISTI Gli apparecchi sono progettati realizzati per trattamenti di incubazione ICT essiccatura STF Gli apparecchi sono progettati e realizzati per trattare le sostanze normalmente utilizzate in laboratorio e Gli apparecchi sono progettati e realizzati per essere utilizzati in laboratorio a fini professionali industriali e didattici e Gli strumenti sono utilizzabili nel campo della biochimica nel campo della microbiologia nel campo dell ematologia e nel campo della diagnostica C3 USI NON PREVISTI Sono usi non previsti tutti gli usi non esplicitamente indicati in USI PREVISTI Uso degli strumenti in condizione ambientali diverse da quelle indicate Uso di apparecchi in atmosfere di gas esplosivi Uso elettromedicale Lavaggio dello strumento con d acqua Utilizzo di acidi e solventi a contatto diretto con lo strumento ATTENZIONE FALC INSTRUMENTS non si assume responsabilit per eventuali danni a persone animali o cose dovuti ad un utilizzo non conforme agli usi sopra citati 9 0 ACCESSORI Ripiano in lamiera forata in acciaio INOX 720 2091 55 720 2091 58 720 2091 62 720 2091 74 720 2091 80 Tavolo porta stufe smontabile in lamiera d
10. 31 C decreasing linearly to 50 at 40 C 2 Before connecting the instrument to the power supply please check the voltage data 5 2 STARTING 1 ELECTRICAL CONNECTION The instrument can be powered by using only one supply point placed on the back side of the device 2 STARTING TEST Before proceeding to use this instrument in a regular and continuative way verify its perfect functioning by carrying out a complete test cycle 3 INSTRUMENT SWITCHING ON Insert the plug of the power supply cable in the network socket 220 240 V 50 60Hz Move the IG general switch into the position Rotate the timer knob to the desired time display turns on and the instrument starts heating up 4 SET PHASE The SET POINT value appears by pressing button Og If no button is pressed within 4 seconds the display starts showing the current temperature again Press button org to set the desired temperature value p save the set temperature value press button The instrument starts showing the room current temperature again Rotate the knob 3 to regulate the fan speed only model STF F In the central position under the display there is a three LED deviation indicator one central green LED and two lateral red LEDs There are 5 possible signals gt The temperature is 1 5 C lower than the SET POINT 4 gt The temperature is within 1 0 C of the SET POINT Fa gt The temperature is 0 5 C fr
11. ELE STATICO aa Solid state relay 1 24v UP 2 H a O 4 N 12 14 MODELLO ICT PORTA FUSIBIEL REGOLATORERPM D SPIA LUMINOSA GIALLA 0 RESISTENZA CORAZZATA SPIA LUMINOSA rossa P TERMOSTATOI DI SICUREZZA Q RELE STATICO OOQGOOO Solld state relay 1 wT 8 FINDER O N 13 14 15 0 DEMOLIZIONE 15 1 QUALIFICA DELL OPERATORE Operatore qualificato chi ha letto recepito 1 contenuti nel capitolo SICUREZZA a pag 2 1 contenuti del capitolo DEMOLIZIONE a pag 14 15 2 DISATTIVAZIONE E DEMOLIZIONE Una volta raggiunta la fine della vita tecnica e operativa dello strumento lo strumento deve essere disattivato La messa fuori servizio e in condizioni di non essere piu utilizzato per gli scopi per a suo tempo era stato progettato e costruito deve poter comunque rendere possibile il riutilizzo delle materie prime che lo costituiscono E necessario effettuare una disattivazione e una demolizione in sicurezza dello strumento ATTENZIONE FALC INSTRUMENTS non si assume alcuna responsabilit per danni a persone cose o animali derivanti dal riutilizzo di singole parti dello strumento per funzioni o situazioni di montaggio differenti da quelle originali 15 5 PROCEDURA DI DISATTIVAZIONE E DEMOLIZIONE Le operazioni di disattivazione e demo
12. It 1s possible to ask the FALC to release a copy of the SIT certification Time periods to reach different temperatures are 7e 150 300 srn 70 iso 300 min 15 25 60 rier 70 11807 sane min 40 60 sort min 45 90 12014 min 60 100 I20Lt 12 25 60 min 40 50 807 Time periods to reach different temperatures are approximate and when they were calculated the chamber was empty 10 14 14 0 ELECTRICAL SCHEME STF F MODEL B FUSEDOOR L RPM REGULATOR C IGREENSWITCH GREEN WARNING LIGHT D N RELAY YELLOWWARNINGLIGHT ARMOURED RESISTANCE REDWARNINGLIGHT P ENGINE LG SAFETY THERMOSTAT Q STATICRELAY 6543 OOQGOOO Solid state relay 1 2 11 14 STF N MODEL COMPONENTI B FUSEDOOR L RPM REGULATOR D WDRESTIMER N RELAY YELLOW WARNING LIGHT O ARMOURED RESISTANCE REDWARNINGLIGHT Jr LG SAFETY THERMOSTAT Q STATICRELAY Q A nus LL SC 6543 21 OOQGOOO Solid state relay 1 av ical 2 12 14 ICT MODEL B Fusepoon RPM REGULATOR D WDRESTIMER N RELAY LE YELLOWWARNINGLIGHT ARMOURED RESISTANCE CF RED WARNING LIGHT P LG SAFETYTHERMOSTAT o SIATIC RELAY O o o L
13. MANUALE D USO MAINTENANCE amp MANUTENZIONE USERS MANUAL NT E M STUFE ED OVENS AND INCUBATORI INCUBATORS 02 80 120 240 400 Lt 52 80 120 240 400 Lt E G a FALC INSTRUMENTS s l Treviglio BG Italy bw INDICE SICUREZZA MT pag 1 ll GENERAL eee eee pag 1 1 2 QUALIFICA DELE OPERATORE rere ads pag 1 1 3 SISTEMI DI SICUREZZA DELLO STRUMENTO I pag 1 20 OPERAZIONI PRELIMINAR cours prisa pag 1 2 1 VERIFICA DEI DANNI DOVUTI AL pag 1 2 2 IN CASO DIDANN Li it a pag 2 2 9 PULIZIA DEELOSTRUMENTO cotas pag 2 3 0 CARATTERISTIHE DELO STRUMENTO pag 2 pag 4 5 0 INSTALLAZIONE E PROCEDURA D UTILIZZO cene I mmm pag 5 Sd CARATTERISTICHE FISICHE ui pag 5 9 2 MESSA IN FUNZIONE culle pag 5 6 0 REGOLAZIONE MANUALE PER RICAMBIO ARIA E SUO UTILIZZO pag 6 TO VENTILAZIONE iiti uaa iii pag 6 8 0 WS PREV iS TT ENON PREVISLL sociale EP RENDERE TENE pag 7 2 0 ACCESSORI piglia aaa pag 7 100 MANUTENZIONE sereni lalla pag 8 10 1 MANUTANZIONE DELLO STRUMENTO ccc cc cece cece eee e eens pag 8 10 1 1 MANUTENZIONE ORDINARIA siria pag 8 10 1 2 MANUTENZIONE PROGRAMMATA sse pag 8 W PULMAN ai pag 8 10 2 1 ATTREZZI E PRODOTTI PER LA PULIZIA ee
14. a camera e per evitare troppi scompensi termici quando si apre la porta dello strumento e SECONDA SICUREZZA sicurezza meccanica se la temperatura supera il valore di 120 C ICT 350 C STF F e STF N si accende la spia ed il riscaldamento smette di funzionare Per ripristinare lo strumento aspettare che la temperatura interna della camera si sia abbassata e premere il pulsante SAFETY Lo strumento riprender 11 funzionamento ATTENZIONE gt se le condizioni di allarme si dovessero ripresentare contattare l assistenza tecnica Per ulteriori informazioni fare riferimento al capitolo RISOLUZIONE PROBLEMT a pag 9 FALC INSTRUMENTS non si assume alcuna responsabilit per eventuali danni a persone animali o cose derivanti dal mancato rispetto delle precauzioni prescritte o dal mancato utilizzo dei DPI prescritti 2 0 OPERAZIONI PRELIMINARI 2 1 VERIFICA DEI DANNI DOVUTI AL TRASPORTO Verificare lo stato dello strumento tramite un ispezione visiva dopo aver aperto l imballo con delicatezza Eventuali deformazioni delle parti visibili indicano urti subiti dallo strumento durante il trasporto che potrebbero compromettere 1l normale funzionamento In particolare verificare 11 buono stato delle seguenti parti Struttura dello strumento Comandi e spie Controllare il serraggio delle vidi e dei bulloni 1 14 2 2 IN CASO DI DANNI I danni dovuti al trasporto devono essere attribuiti al trasportatore segnalati immedia
15. agionevolmente prevedibili La documentazione completa delle misure adottate ai fini della sicurezza contenuta nel fascicolo tecnico dello strumento depositato presso 1l fabbricante Il fabbricante raccomanda di attenersi scrupolosamente alle istruzioni procedure e raccomandazioni contenute in questo manuale ed alla vigente legislazione sulla sicurezza nell ambiente di lavoro anche per l utilizzo dei dispositivi di protezione previsti FALC INSTRUMENTS non si assume responsabilit per eventuali danni a persone animali o cose derivanti dall impiego di operatori non qualificati e o dall uso improprio dello strumento 1 2 QUALIFICA DELL OPERATORE Le operazioni di installazione dello strumento devono essere effettuate esclusivamente da personale addestrato qualificato ed autorizzato dopo aver studiato il manuale d uso 1 3 SISTEMI DI SICUREZZA DELLO STRUMENTO Lo strumento ha due tipi di sicurezza uno di tipo digitale che si imposta automaticamente di 2 C o 5 C superiore al set point ed uno di tipo meccanico che interviene quando la temperatura di esercizio supera il limite massimo di 120 C o 350 C e PRIMA SICUREZZA sicurezza digitale Se la temperatura supera di 2 C modelli ICT o 5 C modelli STF il set point si accende 11 led La sicurezza si disinserisce automaticamente non appena le condizioni di temperatura siano rientrate nella norma Questa sicurezza utilizzata anche per mantenere costante la temperatura all interno dell
16. authorized personnel These are periodic or precautionary inspections and interventions If any problem persists after the intervention of qualified and trained personnel please contact the technical assistance 10 2 CLEANING ATTENTION Switch off the instrument and disconnect it from the power supply before proceeding with any cleaning operation At the end of every day proceed with an accurate general cleaning of the instrument Please pay particular attention to the following areas Instrument chamber Instrument surrounding surface Work area flooring 10 2 1 CLEANING TOOLS AND PRODUCTS Cleaning operations can be carried out with a normal detergent and water Use isopropanol only if dirt is difficult to remove ATTENTION Do not use any solvents as these may damage the varnish and the synthetic materials In particular avoid the use of petrol nitro perchlorate and trichlorethene 10 3 TRASPORT If transportation 1s carried out on road vehicles with an open container make sure the instrument its outfit and the packing are completely covered with a plastic wrapping to protect them from atmospheric agents 10 4 STORAGE All the conditions contained in this section must be respected during the storage period of the instrument Altitude up to 2000m Allowed temperatures from 5 C to 40 C Maximum relative humidity of 80 for temperatures up to 31 C decreasing linearly to 50 at 40 C Suitable protection f
17. complete instruction manual 1 3 INSTRUMENT SAFETY SYSTEMS The instrument has 2 different types of safety systems a digital one which 15 set automatically 2 C o 5 C over the set point and a mechanical one which is activated when the instrument temperature exceeds the maximum limit of 120 C or 350 C FIRST SAFETY SYSTEM digital safety system When temperature is 2 C ICT models or 5 C STF models higher than the set point the led turns on automatically This safety system disconnects automatically as soon as the temperature returns to normal This safety system 15 also used to keep the internal temperature of the chamber constant and to prevent thermal imbalances when opening the instrument door SECOND SAFETY SYSTEM mechanical safety system When temperature exceeds 120 C ICT or 350 C STF F e STF N the warning light au turns on and the heating system stops working Wait until the internal temperature of the chamber decreases and press the SAFETY button to restart the instrument Lad The instrument will start working again ATTENTION gt Please contact the technical assistance if the warning signals appear again For further information read chapter PROBLEM SOLVING on page 9 FALC INSTRUMENTS declines any liability for any damages to people animals or objects resulting from failure to comply with precautions contained in this manual or from failure to use the prescribed PPD personal protection devices
18. da ambiente 5 a 300 INCUBATORI RIPIANI GRIGLIATI AGGIUNTIVI RICAMBIO 720 2091 05 720 2091 08 720 2091 12 720 2091 24 720 2091 40 3 14 4 0 COMANDI Regola la quantita d aria che deve passare dal camino posteriore Visualizza la temperatura corrente o la 1 Display temperature impostata 51 accende quando le resistenze sono in funzione o durante la fase di set 4 51 accende quando la temperatura inferiore all impostazione 51 accende quando la temperatura uguale all impostazione 51 accende quando la temperatura superiore all impostazione Si accende durante la fase di set o se il set point superato di 2 C o 5 C PAS Conferma le modifiche effettuate Incrementa la temperatura impostata Decrementa la temperatura impostata Si accende quando lo strumento sta operando Si accende quando in funzione la ventola Si accende in caso di allarme 6 Imposta il tempo Serve per ripristinare manualmente la IG seconda sicurezza EN Regola la velocit della ventola Serve per accendere e spegnere lo strumento Porta fusibili Per 1 modelli da 240Lt e 400Lt 4 14 5 0 INSTALLAZIONE E PROCEDURA D UTILIZZO 5 1 CARATTERISTICHE FISICHE Le operazioni devono essere effettuate da personale addestrato qualificato ed autorizzato vedere capitolo riguardante la sicurezza 1 Collocare lo strumento in luoghi ritenuti idonei per l utilizzo norma D L 626 94
19. e pag 8 LOD TRASPORTO aa etait atis arreda pag 8 ININFAGAZZINAMENTO St A aa pag 8 FEO RISOEUZIONE PROBLEM rat ib pag 9 120 RICAMBTDELCOSTRUTTORE sis mida it pag 10 13 0 DICHIARAZIONE DI CALIBRAZIONE HH pag 10 14 0 SCHEMA PBLETTRI CO ri di pag 11 1530 DEMOLIZIONE usaste pag 14 SL QUALIFICA DELL OPERATORE src is ei Uo Dui caus ied D eoe pag 14 15 2 DISINSTALLAZIONE E DEMOLIZIONE Cleese pag 14 15 3 PROCEDURA DI DISINSTALLAZIONE E DEMOLIZIONE pag 14 15 4 RISCHI RESIDUI DOPO LA DEMOLIZIONE n pag 14 Questo manuale deve essere conservato per tutta la vita tecnica dello strumento in modo da essere facilmente reperibile in caso di necessit In caso di vendita dello strumento usato dovr essere venduto completo di questo manuale Conservare il manuale in luoghi asciutti e facilmente accessibili per una rapida consultazione Non sporcare il manuale per evitare di creare macchie che impediscano la lettura del testo 10 SICUREZZA 1 1 GENERALE Nella progettazione e nella costruzione di questo apparecchio sono stati adottati 1 criteri e gli accorgimenti adatti a soddisfare 1 requisiti essenziali di sicurezza previsti dalla Direttiva Bassa Tensione 2006 95 CE L accurata analisi dei rischi svolta ha consentito di eliminare la maggior parte dei rischi connessi alle condizioni di uso dell apparecchio sia previste che r
20. ed to be a RAEE disused electrical or electronic device according to the following directives 2002 95 CE 2002 96 CE 2003 108 CE Deposit the instrument at an authorized disposal site 15 4 POST DEMOLITION RESIDUAL RISKS If all the instructions indicated in chapter DEACTIVATION AND DEMOLITION on page 14 are followed meticulously there are no post demolition residual risks 14 14 Via Monzio Compagnoni 2 24047 Treviglio BG ITALY Tel 39 0363 304660 Fax 39 0363 304395 e mail fale falcinstruments it web site www falcinstruments it FALC INSTRUMENTS s r l OGGETTO GARANZIA Per garanzia si intende la pura e semplice sostituzione per un periodo limitato a 24 mesi dalla data di consegna delle parti risultate difettose per manifestati vizi di fabbricazione Lo strumento dovra pervenire franco nostro stabilimento allegando possibilmente una breve descrizione del difetto riscontrato e se 1 vizi saranno accettati verr riparato e spedito con spese di trasporto a carico nostro Sono altresi esclusi dalla garanzia 1 particolari di normale usura elementi riscaldanti La garanzia decade qualora l apparecchio presenti modifiche apportate manomissioni o comunque eseguite riparazioni da parte di persone non autorizzate FALC INSTRUMENTS s r l OBJET GARANTIE On entend par garantie la remplacement pur et simple pendant une p riode limit 24 mois compter de la date de livraison de pi ces s
21. el Pulling the lever upward the air vent hole closes while pulling the lever down the air vent hole opens This opening can be connected to an intake system or used as a cable entrance 7 0 VENTILATION To ensure a good working of the instrument and a good air circulation inside the chamber arrange the materials leaving some S GNE E CS space between one test piece and another and make sure the vent for the air circulation of the engine 15 not obstructed NNO o e o n 9 6 14 8 0 FORESEEN AND UNFORESEEN USES FORESEEN USES These instruments are engineered and constructed for incubation ICT or desiccation STF treatments These instruments are engineered and constructed to treat substances that are normally used in laboratories These instruments are engineered and constructed to be used in laboratories for professional industrial and didactic purposes lr GF Y These instruments can be used in the field of biochemistry microbiology haematology and diagnostics C9 UNFORESEEN USES All uses are unforeseen unless specifically indicated in the FORESEEN USES Use of the instruments in environmental conditions different from those indicated Use of the instruments in explosive gas atmospheres Electromedical use Water jet cleaning 49 29 29 49 9 Acids and solvents must not come into direct contact with the instruments ATTENTION FALC INSTRUMENTS declines any liability for any damages t
22. lizione dello strumento devono essere affidate solo a personale adeguatamente addestrato ed equipaggiato Spegnere lo strumento Scollegare le fonti di alimentazione Smontare le seguenti parti Parti elettriche Parti in plastica Piedini di supporto in resina Nel caso di movimentazione dello strumento fare riferimento ai capitoli INSTALLAZIONE E PROCEDURA D UTILIZZO pag 5 TRASPORTO e IMMAGAZZINAMENTO pag 8 ATTENZIONE Lo strumento realizzato con materiali non biodegradabili Lo strumento considerato un RAEE secondo normativa 2002 95 CE 2002 96 CE 2003 108 CE Portare lo strumento in un deposito autorizzato per lo smaltimento 15 4 RISCHI RESIDUI DOPO LA DEMOLIZIONE se le indicazioni della sezioni DISINSTALLAZIONE E DEMOLIZIONE pag 14 sono eseguite accuratamente non esistono rischi residui dopo la disattivazione 14 14 INDEX RES ee ENERO ee Ua page li ENE T page 12 OPERATOR OU ALABIC ATION ss page 1 ES INSTRUMENT SAFETY SYSTEMS 4 dais page 1 2 0 PRELIMINARY OPERATIONS ir Va eoe a Ern ote page 1 1 1 VERIFICATION OF TRANSPORTATION 1 22 JN CASE OF DAIDAGOE ie 2 2 5 CLEANING KINSERUMENT air page 2 3 0 INSTRUMENTCHARACTERIS TT OS DALE 2 A CONTROLS rrr UE page 4 5 0 INSTALLATION AND USE PROCEDURES 0odirasasiadanras umida daa dose trus teb
23. nica 9 14 12 0 RICAMBI DEL COSTRUTTORE 600W 700W 800W 1300W 1700W CODICE ER0035 ER0036 ER0037 ER0038 ER0039 Nota le resistenze sono due in ogni strumento 13 0 DICHIARAZIONE DI CALIBRAZIONE Per la calibrazione stata utilizzata una catena termometrica tarata in riferimento alla catena termometrica certificata SIT possibile richiedere una copia del certificato SIT depositato presso il costruttore I tempi per il raggiungimento delle temperature sono 150 300 7 iso so icr 70 sui mi 15 25 6 min 40 60 min 45 90 min 12 35 60 min 60 100 min 50 I tempi di raggiungimento sono indicativi e sono stati riscontrati con la camera vuota 10 14 14 0 SCHEMA ELETTRICO MODELLO STF F PORTA FUSIBILI L REGOLATOREREM _ SPIA LUMINOSA VERDE D TIMER Es N RELE SPIA LUMINOSA GIALLA O RESISTENZA CORAZZATA SPIA LUMINOSA ROSSA P MOTORE LG TERMOSTATOIDISICUREZZA Q RELE STATICO CL 6 543 21 OOQGOOOQ Solid state relay 1 2 11 14 MODELLO STF N NR A JFUSIBIL I SONDAPTIOO O PORTA FUSIBLE LO REGOLATORERPM D TIMERE ET SPIA LUMINOSA GIALLA O RESISTENZA CORAZZATA T SPIA LUMINOSA ROSSA TERMOSTATOI DI SICUREZZA Q R
24. nts or part due to faults or defect of our manufacturing process not due to transport or misuse as soon as we are informed and the item sent back to us for verification The item should be sent back to us at your charge with a report explaining and describing the fault When the problem has been verified and confirmed the item shall be substituted or changed repaired and sent back to the customer free of charge In a case the item has been tampered with misused or used not following the instructions or in case wrong repair trials have been done on it there shall be no guaranty whatsoever FALC INSTRUMENTS s r l Dichiarazione di conformita CE Declaration of CE conformity Costruttore Manufacturer FALC INSTRUMENTS s r l Via G Monzio Compagnoni 2 24047 Treviglio BG ITALY Dichiara che il seguente apparecchio conforme alle normative di Sicurezza concernente le DIRETTIVE CE per la COMPATIBILITA ELETTROMAGNETICA 2004 108 CE e la BASSA TENSIONE 2006 95 CE The following unit complies with the safety requirements outlined by the EC DIRECTIVE concerning the guidelines for ELECTROMAGNETIC COMPATIBILITY 2004 108 EC and LOW VOLTAGE REGULATIONS 2006 95 Lo strumento costruito secondo la normativa The units are manufactured in compliance with the regulations CEI EN 61000 6 2 CEI EN 61000 6 4 CEI EN 61010 1 CEI EN 60355 1 CEI EN 61326 1 Il responsabile legale legal responsable Scotti Francesco
25. nual must always accompany the instrument even if it 1s sold to another user Keep this manual in a well protected and easy accessible place in order to permit a quick consultation in case of need We also suggest to keep this manual in a clean place in order to avoid the formation of stains that could make it difficult to read the text 10 SAFETY 1 1 GENERAL Falc Instruments declares that the engineering and construction of this instrument comply with the criteria and notions that satisfy the basic safety requirements under the Low Voltage Directive 2006 95 CE A meticulous risk analysis carried out by the manufacturer made it possible to eliminate most of the risks that were connected to both foreseen and reasonably predictable instrument use conditions Full documentation of all the adopted safety measures can be find in the instrument technical file held by the manufacturer The manufacturer recommends that users strictly observe all instructions procedures and recommendations contained in this manual and stick to the current workplace safety regulations even when using the protection devices FALC INSTRUMENTS declines any liability for any damages to people animals or objects resulting from an improper use of the instrument or from use by unqualified operators 1 2 OPERATOR QUALIFICATION All the instrument installation operations must be carried out exclusively by trained qualified and authorized personnel after studying the
26. o people animals or objects resulting from failure to comply with precautions contained in this manual 9 0 ACCESSORIES INOX steel perforated plate 720 2091 55 720 2091 58 720 2091 62 720 2091 74 720 2091 80 Collapsible oven table In steel plate painted in oven with antacid epoxy dust 5214 8014 80Lt 120Lt 800x650x850 900x750x800 720 2091 92 720209193 Oventrolley In steel plate painted in oven with Oven TOP antacid epoxy dust with swivel wheels Aluminium profile table with shelf in anodized 9150 and brake 240Lt 40014 5214 8014 801 12014 1000 800 500 800x650x850 900x750x800 720 2091 98 720 2091 95 720 2091 96 Note all measures are expressed in mm 7 14 10 0 MAINTENANCE 10 1 INSTRUMENT MAINTENANCE Before embarking on any maintenance work check that the instrument is switched off and is not connected to the power supply and make sure all its parts are cold Maintenance operations must be carried out exclusively by trained qualified and authorized maintenance personnel after studying and understanding all the instructions contained in this section 10 1 1 ORDINARY MAINTENANCE Ordinary maintenance operations can be carried out by the user These are cleaning operations and periodic or precautionary inspection operations that ensure a safe use of the instrument 10 1 PROGRAMMED MAINTENANCE Programmed maintenance operations can be carried out exclusively by
27. om the SET POINT gt The temperature is within 1 0 C of the SET POINT gt Thetemperature is 1 5 C higher than the SET POINT 5 14 5 INSTRUMENT SHUTDOWN PROCEDURE Move the IG general switch into the O position Remove the containers from the instrument ATTENTION gt handling of hot objects Disconnect the instrument from the power supply NOTE If for any reason a treatment has to be interrupted before the end of a cycle do NOT force the knob to move the TIMER into the O position ATTENTION FALC INSTRUMENTS declines any liability for any damages to people animals or objects resulting from failure to comply with precautions contained in this manual or from failure to use the prescribed PPD personal protection devices See chapter SAFETY on page 1 6 0 MANUAL REGULATION FOR AIR VENTILATION AND ITS USE 52Lt SOLt and 120Lt models This air vent hole has a diameter of 45mm and 15 placed on the back side of the instrument It 1s possible to regulate this opening using the knob placed on the control panel Turning the knob clockwise the air vent hole closes while turning the knob anticlockwise the air vent hole opens This opening can be connected to an intake system or used as a cable entrance 240Lt and 400Lt models This air vent hole has a diameter of 45mm and 15 placed on the back side of the instrument It 1s possible to regulate this opening using the lever placed on the control pan
28. orssas PAZE 24d PHYSICAL CHARACTERISTICS ia A dr p dtd page 5 32 STAR LIN Ca 6 0 MANUAL REGULATION FOR AIR VENTILATION AND ITS USE page 6 Ca NEUE WB Plc PCT a page 6 5 0 POISESEEN AND UNFORESEEN TU SB page 7 DUS ACCESSORIES alunne page 7 MAINTENANCE ui FORO ERE AO DES UE ieee under e Ebo AERE VEU RPM page 8 INSTRUMENT MAINTENANCE A Rex MR SE page 8 10 1 1 ORDINARY I emnes nnn page 8 0 12 PROGRAMMED MAINTENANCE sd page 8 10 2 CLEAN UNGS ant ariana etere aida page 8 10 2 1 CLEANING TOOLS AND PRODUCTS eem 8 FOS TRANSPORE gle page 8 IO STORAGE Guanica lariana Dace S TLO PROBEENESOLNING scia A A la page 9 12 0 MANUFACTURER SPARE PARTS uti iaa page 10 13 0 DECLARATION OF CALIBRATION iii page 10 40 ELECTRICAL SCHEME ra dra page 11 15 05 DE 14 EEIOUN e page 14 15 1 OPERATOR QUALIFICATION a penes page 14 52 DEACTIVATION AND DEMOLITION ii Tia page 14 15 3 DEACTIVATION AND DEMOLITION PROCEDURE page 14 15 4 POST DEMOLITION RESIDUAL RISKS nnn page 14 This manual must be kept by user for the whole technical life of the instrument in order to be immediately available in case of need This ma
29. perature is lower than the set temperature Decreases the set temperature Turns on when the instrument is working k i l t TE Turns on when the fan is working Sets the time IG Serves to manually restart the second band safety system EN Regulates the fan speed Serves to turn the instrument on and off Fuse door For 240Lt and 400Lt models 4 4 14 5 0 INSTALLATION AND USE PROCEDURES 5 1 PHYSICAL CHARACTERISTICS All operations described in this manual must be carried out by trained qualified and authorized personnel see chapter SAFETY 1 Place the instrument in a suitable location Risk evaluation in accordance with the decree law 626 94 of the Italian legislation Please consider the instrument volume and make sure the following conditions are satisfied The instrument is placed in the immediate vicinity of a power source There is sufficient space around the instrument for normal use maintenance and any peripheral equipment The instrument must be placed in a covered location in order to prevent any contact with atmospheric agents For a safe working and maintenance of the instrument a good lighting is required A normal ambient light will prevent any risk on work connected to shade areas For a normal functioning of the instrument the allowed temperature goes from a minimum of 5 C to a maximum of 40 C with a maximum relative humidity of 80 for temperatures up to
30. rima che il tempo sia trascorso completamente NON forzare la manopola per portare il TIMER in posizione 0 ATTENZIONE FALC INSTRUMENTS non si assume alcuna responsabilit per eventuali danni a persone cose o animali derivanti dal mancato rispetto delle precauzioni prescritte o dal mancato utilizzo dei DPI prescritti Vedi capitolo SICUREZZA a pag 1 6 0 REGOLAZIONE MANUALE PER RICAMBIO ARIA E SUO UTILIZZO 7 0 VENTILAZIONE Modelli da 52Lt SOLt e 120Lt Questo foro ha un diametro di 45mm ed posto nella parte posteriore dello strumento possibile regolare questa apertura mediante l utilizzo della manopola che si trova sul frontalino Ruotando in senso orario si chiude 1il foro per l aria mentre ruotando in senso antiorario il foro si apre possibile collegare questa apertura ad un impianto d aspirazione o essere utilizzata per l ingresso di cavi Modelli da 240Lt e 400Lt Questo foro ha un diametro di 45mm ed posto nella parte posteriore dello strumento possibile regolare questa apertura mediante l utilizzo della manopola che si trova sul frontalino Spostando la manopola verso l alto si chiude il foro per l aria mentre spostandola verso il basso il foro si apre possibile collegare questa apertura ad un impianto d aspirazione o essere utilizzata per l ingresso di cavi Per un buon utilizzo dello strumento e per mantenere una O O O in del motore buona circolazione dell aria all
31. rom atmospheric agents There is sufficient space to safely execute all the lifting and transport operations The horizontal support base capacity is higher than the instrument weight DO NOT PUT ANY OBJECTS ON THE INSTRUMENT 8 14 11 0 PROBLEM SOLVING In case of need the instrument can only be repaired by the manufacturer Falc Instruments or by trained and authorized personnel Spare parts codes are indicated in the following chapter MANUFACTURER SPARE PARTS Type of failure Problem solving Fuse control Disconnect the instrument from the power supply The instrument does not Open the small drawers located below the tag turn on Remove the fuses and in case they are blown replace them with new fuses with the same amperage and voltage rating as the previous ones Close the small drawers Verify that the thermoregulator parameters are set correctly contact the technical assistance If the problem persists replace the static relay Disconnect the instrument from the power supply Disassemble the lateral panel using a screwdriver or another similar tool Unscrew the two self tapping screws that hold the static relay The instrument does not Disconnect the relay from the rest of the incubator heat Connect the new static relay paying attention to the polarity Use the two self tapping screws to connect the new static relay Assemble the lateral panel OTHERWISE The failure 15 caused by the malfuncion of the instrumen
32. sino a 31 C con diminuzione lineare sino a 50 con temperatura di 40 C Protezione adeguata da agenti atmosferici Spazio richiesto sufficiente a effettuare le operazioni di sollevamento e trasporto 1n maniera sicura e agevole Piano di appoggio orizzontale con portata superiore alla massa dello strumento NON APPOGGIARE NESSUN OGGETTO SOPRA LO STRUMENTO 8 14 11 0 RIUSOLUZIONE PROBLEMI In caso di riparazione l apparecchio puo essere riparato solo dalla ditta costruttrice Falc Instruments o da personale addestrato e autorizzato I codici per 1 pezzi di ricambio si trovano nel capitolo successivo RICAMBI DEL COSTRUTTORE Guasto riscontrato Risoluzione problema Controllo dei fusibili Lo strumento non si accende Lo strumento non scalda Lo strumento continua a scaldare Il display mostra U U U U OOOO 1 2 3 4 Scollegare lo strumento dalla linea di alimentazione Aprire 1 cassettini posti subito sotto etichetta Estrarre 1 fusibili e se bruciati riposizionare nei cassettini altri nuovi fusibili con uguale amperaggio e voltaggio dei precedenti Chiudere 1 cassettini Verificare che 1 parametri del termoregolatore siano impostati in maniera corretta contattare l assistenza tecnica Se il problema persiste sostituire il rel statico Scollegare lo strumento dalla linea di alimentazione Smontare il pannello laterale mediante l utilizzo di un cacciavite o attrezzi simili Svitare le due viti au
33. t resistances For further information please contact the technical assistance Verify that the thermoregulator parameters are set correctly contact the technical assistance If the problem persists replace the static relay Disconnect the instrument from the power supply Disassemble the lateral panel using a screwdriver or another similar tool Unscrew the two self tapping screws that hold the static relay Disconnect the relay from the rest of the incubator Connect the new static relay paying attention to the polarity Use the two self tapping screws to connect the new static relay Assemble the lateral panel The instrument keeps heating Verify that the probe is properly connected to the instrument and 1s working correctly The display shows T All the failures described above can be attributed to an incorrect use of the instrument to the technical life and to the daily wear and tear of the components If the authorized and trained personnel can not solve a particular problem please contact the technical assistance 9 14 12 0 MANUFACTURER SPARE PARTS Static relay for 52Lt 80Lt 120Lt RT0004 Static relay for 240Lt 400Lt RT0005 Probe SN0006 Mechanical timer 0 12h oo TR0020 Note each instrument 15 provided with two resistances 13 0 DECLARATION OF CALIBRATION Calibration was performed using a thermometric chain calibrated in accordance with the SIT centre certified thermometric chain
34. tamente al fabbricante al suo responsabile Inviare una lettera di contestazione al trasportatore 2 3 PULIZIA DELLO STRUMENTO Togliere la polvere e lo sporco esterni accumulati durante le fasi di trasporto 3 0 CARATTERISTICHE DELLO STRUMENTO CARATTERISTICHE COMUNI Dimensioni interne LxPxH 390x350x390 450x400x450 500x470x520 A Tus Sn _ E _ Max ripiani CETTE Omemwm ees 2 2 _ Conco maso persono Ke w _ Comes m eee e I peso stato calcolato distribuendolo uniformemente sull intero piano d appoggio Struttura in acciaio verniciata a forno con polvere epossidica antiacida Camera interna in acciaio INOX Porta con doppio sistema di bloccaggio per una perfetta tenuta Foro 45mm sul lato posteriore per scarico fumi o passaggio cavi Foro 10mm sul lato superiore per inserimento termometro Controllo della temperatura con microprocessore ad azione PID Timer da 0 a 12 ore con possibilit di impostare infinito Gli incubatori sono forniti di una seconda porta in vetro per poter ispezionare l interno della camera senza creare scompensi termici 2 14 STUFE A VENTILAZIONE FORZATA Temp di utilizzo C da ambiente 5 a 300 70 1 0 1 0 1 0 1 5 Potenza riscaldante 1200 1400 1600 2600 3400 720 2090 05 720 2090 08 720 2090 12 720 2090 24 720 2090 40 STUFE A VENTILAZIONE NATURALE Temp di utilizzo EN
35. tofilettanti che tengono 1l rel statico Scollegare 11 rel del resto dell incubatore Collegare il nuovo rel statico facendo molta attenzione alle polarit Avvitare il nuovo rel statico tramite le due viti autofilettanti Rimontare il pannello laterale OPPURE Il guasto dipende dal mal funzionamento delle resistenze dello strumento Per ulteriori informazioni contattare l assistenza tecnica 1 Verificare che 1 parametri del termoregolatore siano impostati in maniera corretta contattare l assistenza tecnica Se il problema persiste sostituire il rel statico Scollegare lo strumento dalla linea di alimentazione Smontare il pannello laterale mediante l utilizzo di un cacciavite o attrezzi simili Svitare le due viti autofilettanti che tengono 1l rel statico Scollegare il rel del resto dell incubatore Collegare il nuovo rel statico facendo molta attenzione alle polarit Avvitare il nuovo rel statico tramite le due viti autofilettanti Rimontare il pannello laterale Verificare la corretta connessione della sonda con lo strumento e quindi verificare il corretto funzionamento della sonda Il display mostra I guasti descritti sono riconducibili ad un utilizzo dello strumento non conforme alle procedure del manuale alla vita tecnica dei vari componenti e all usura del tempo Qualora il personale autorizzato ed addestrato non sia in grado di risolvere un determinato problema contattare l assistenza tec
36. ve e di interventi sullo strumento Qualora il personale autorizzato ed addestrato non sia in grado di risolvere un determinato problema contattare l assistenza tecnica 10 2 PULIZIA ATTENZIONE Eseguire le operazioni di pulizia con lo strumento spento e sezionato dalla linea di alimentazione A termine di ogni giornata lavorativa eseguire un accurata pulizia generale dello strumento in particolare delle seguenti zone Camera dello strumento superficie circostante dello strumento Pavimentazione della zona di lavoro 10 2 1 ATTREZZI E PRODOTTI PER LA PULIZIA Per le operazioni di pulizia sufficiente disporre di un normale detergente e di acqua Utilizzare isopropanolo solo in caso di sporcizia dura da eliminare ATTENZIONE Evitare l uso di solventi che danneggiano la vernice e 1 materiali sintetici In particolare evitare l uso di benzina diluente nitro perclorato e trielina 10 5 TRASPORTO Se 1l trasporto avviene su veicoli stradali con cassone aperto bisogna assicurarsi che lo strumento il suo corredo e l imballo siano completamente coperti con una copertura in plastica o equivalente per proteggerli da agenti atmosferici 10 4 IMMAGAZZINAMENTO Le condizioni contenute in questa sezione devono essere rispettate durante 1 periodi di immagazzinamento in attesa di una ricollocazione Altitudine fino a 2000m Intervallo di temperatura ammesso 5 C 40 C Umidit relativa massima 80 per temperature

Download Pdf Manuals

image

Related Search

Related Contents

Scenario Generator - Simulation Software for Healthcare  [春野図書館]基準表(PDF形式:90KB)  User-Manual - Newegg.com  「CD/USBレシーバー ファームウェア アップデート説明書」を  取扱説明ョ  OnCell Central Manager User`s Manual  Sony IJP-V100 Marketing Specifications    Micronet GFB1000EU external hard drive  GX Works2 Version 1 Operating Manual (Simple Project, Function  