1. 10 9 Half range sensible horizontal Maximum 8 zone dimension m sensitivity 7 6 5 4 3 Minimum sensitivity 2 1 Range m 10 20 30 40 50 60 70 80 90 100 Figure 3 Free space Horizontal dimension of the sensible beam at half range for MANTA 50 80 E Half alf range 18 sensible vertical Hd 16 dimension m 14 12 10 8 6 H Minimum 4 sensitivity 2 Range m 10 20 30 40 50 60 70 80 90 100 Figure 4 Free space Vertical dimension of the sensible beam at half range for MANTA 50 80 Remark for the MANTA equipment the sensitivity adjustment used to obtain the dimensions of the sensitivity beam at half section length is by adjusting the thresholds The higher the pre alarm and alarm thresholds the lower the sensitivity and vice versa It is important to remember that the pre alarm threshold determines the start of the intelligent analysis all signals below this threshold are considered noise and of low importance All the signals above this threshold are analyzed following Fuzzy rules The pre alarm and alarm thresholds are adjusted either with WAVE TEST software or with rotary switches on board on each receiver Defa
2. Barriera a Microonde per protezioni esterne Manuale di Installazione External Microwave Protection Barrier Installation Handbook Edizione Edition 1 2 CIAS Elettronica S r l Ed 1 2 INDICE I N DI CRIZIONE 3 1 12 ccc 3 2 INSTALEA ZIONE ORE EDD 3 2 1 INFORMAZIONI PRELIMINARI ne ee eee ene ze cene ene eee eee eee eee 3 2 2 NUMERO DE TRATTE tree ertet lalla ele aa BER lattanti 4 2 3 CONDIZIONI DEL TERRENO cdi ila E LIO LI LL E ii 5 2 4 PRESENZA DI OSTACOLI ehi 5 2 5 AMPIEZZA DEI FASCI SENSIBILI eee eee nei ze e eee eee eee ei 6 2 6 LUNGHEZZA DELLE ZONE MORTE IN PROSSIMIT DEGLI eee 7 3 COLLEGAMENTI tosses desu sectessscssudesssesssuusccsesusecsivebessisuSusssssucecssesececesadvossssvudsissedesssssevedess 8 3 1 MORSETTIERE CONNETTORI E FUNZIONALIT DEI CIRCUITI 8 3 Jb GCIIGWItodTOsinellilokE s o eU ri va EU rec rris MI E mele EL eye ani 8 3 1 2 RICeVlOF ue eee oP Rca eR AS AE ARREARS 10 3 2 COLLEGAMENTO ALL ALIMENTAZIONE PRINCIPALE 0
3. 1d 3 10485 jLinedatiBassaper RS 485 3 4 3 Configurazione Rete e Rigeneratori di segnale La connessione seriale tra le varie teste di tutte le barriere installate deve essere effettuata mediante cavo schermato intrecciato ed a bassa capacit 70 pF m es Belden 9842 L architettura della rete deve essere di tipo a BUS con una lunghezza massima del bus pari a 1200 m Qualora fosse necessario utilizzare una architettura stellare o la lunghezza massima del bus fosse superiore a 1200 m occorre utilizzare uno o piu ripetitori di linea modello BUS REP Si possono realizzare stesure di cavo con configurazioni diverse completamente stellari miste a bus e stellare utilizzando ripetitori rigeneratori e moltiplicatori di interfaccia BUS REP figura che segue Il numero totale di dispositivi Tx o RX che possono essere connessi sulla linea di 32 per un numero maggiore di dispositivi necessario utilizzare uno o pi rigeneratori di linea RS 485 anche se la lunghezza del cavo inferiore a 1200 m Per un efficace protezione dai disturbi indotti su tale linea occorre assicurare la continuit della connessione dello schermo il quale deve essere connesso a TERRA solo in un punto per esempio in prossimit dell alimentatore Quando vi sono pi barriere connesse sul bus seriale RS 485 la tensione d alimentazione per il convertitore d interfaccia da RS 485 a RS 232 deve essere fornita mediante un alimenta
4. 12 3 2 4 Collegamento all Alimentazione ede ee ae deer ER AER ER HERR TE LIRE 12 3 3 COLLEGAMENTO ALEA CENTRALE ciale lei 13 3 3 1 Contatti di allarme Allarme Guasto Manomissione 13 3 3 2 Connessioni per SINCTONISMNO sana ERE yes DERI Lane se Fes pentes epic eves re SP RUE 14 3 3 3 Connessioni per Stand by s rii m E PER sesh RE UMP prx etie coge 14 3 34 Connessioni per Li ERES ege e eR 14 3 4 EINEA SERIAEERS 485 anuo alla iii Eoo odes eo enne c Qe tete bai ire 15 3 4 1 Interfaccia Linea Seriale RS 485 232 15 3 4 2 Connessioni per Linea Seriale RS 485 seeds eie petet ie PH PREPARES ERR Cd ener 52565 15 3 4 3 Configurazione Rete e Rigeneratori di segnale iii 15 3 5 COLLEGAMENTO DA ACCESSO REMOTO TE EOS 16 4 ALLINEAMENTO E VERIFIGA eeepc ene eaae ea ra RIA ARTO RIA ase terae s Uus 17 AFEINBAMENTO E VERIFICA tete coe et e ee etd eee ce Nee ee dte e beau e tec ee dea eie be e cede EN Pe nece 17 4 1 1 Operazioni sul Tr smettitore used eade uere te eee e ierit E alie aan 17 4 1 2 Operazioni sul Ricevitore cupi etd nO UR RE ES ge De HERE ari inizia 18 4 2 ALLINEAMENTO E VERIFI
5. TP4 AND GND SELEZIONE MASTER SLAVE MASTER MASTER MASTER SLAVE SELECTION O SLAVE SUNE CANALE DI MODULAZIONE SELEZIONATO Ch 0 Cn8 O Cho MODULATION CHANNEL SELECTED OI Chi cna ha 2 Ocha 2 Ch3 Ch3 ChB Ch4 che Ch4 che O 5 ChD O Ch5 ChD O Che che O Ch6 Ch7 ChF Ch7 ChF OSSERVAZIONI DELL INSTALLATORE INSTALLER COMMENTS Data installazione Installation date Firma Installatore Installer Signature SCHEDA DI COLLAUDO TEST SHEET CIAS MANTA RX NUMERO DI SERIE SERIAL NUMBER Cliente Customer Indirizzo Address Barriera Barrier N VALORI MISURATI SUL RICEVITORE MEASURED VALUES ON THE RECEIVER VALORI MISURATI MISURE VALORI TIPICI MEASURED VALUES Ue eS STANDARD INSTALLAZIONE MANUTENZIONE VALUES INSTALLATION MAINTENANCE TENSIONE DI ALIMENTAZIONE MISURATA TRA PIN 1 2 DI MS2 SUPPLY VOLTAGE MEASURED BETWEEN PINS 13 8 VDC 10 1 2 OF MS2 TENSIONE DI ALIMENTAZIONE INTERNA MISURATA TRA TP6 E GND 5 VDC 10 INSIDE SUPPLY VOLTAGE MEASURED BETWEEN TP6 AND GND 3 TENSIONE DI ALIMENTAZIONE INTERNA MISURATA TRA TP7 E GND 8 VDC 10 INSIDE SUPPLY VOLTAGE MEASURED BETWEEN TP7 AND GND TENSIONE DI RAG MISURATA TRA TP9 E GND 4 AGC VOLTAGE MEASURED BETWEEN TP9 AND 25 6 VDC GND cho Ochs Ocho Ochs 5 CANALE DI MODULAZI
6. SW1 FUN Position 1 Barrier alignment Position 2 acquisition of the installation values Channel number and AGC Voltage Position 3 Pre alarm thresholds Read Write Position 4 Alarm thresholds Read Write Walk Test Position 5 Masking thresholds Read Write Position 6 2 Upper Pre alarm thresholds Read Write FSTD Position 7 2 Lower Pre alarm thresholds Read Write FSTD Position 8 Barrier number Read Write Position 9 Monitor thresholds Read Write Position 0 Working Phase PARAMETERS AND BARRIER NUMBER READING AND SETTING SWITCHES SW2 SW3 N Symbol Function O SW2 Decimal rotary switch to read or to set parameters during alignment operation tens column SW3 Decimal rotary switch to read or to set parameters during alignment operation units column PUNTI DI MISURA DEL RICEVITORE Simbolo A Funzone 200mVpp Signal Ns 4 8 TP8 Ground for test point 9 TP9 Automatic Gain Control signal RAG 3 2 Equipment Connection to the Power Supply 3 2 1 Connections to the Power Supply The units must be powered with DC voltage nominal value is 13 8 V The connection between the head and the power supply must use cables of correct cross section The cable cross section must be calculated taking account of the connection length and unit current consumption For very long connections it is recommended that a supplementary power supply is used For the power supply conn
7. gt 14 8V 3 Temperature low lt 35 C internal 4 Temperature high gt 75 C internal 5 RF radio frequency or BF low frequency Oscillator fault on Transmitter Remark 1 if the intrusion signal after passing the pre alarm threshold stays between pre alarm and alarm threshold for 40 sec the barrier gives a stopped target alarm event and the alarm output is activate the contact opens Installation Handbook page 38 of 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 3 3 2 Synchronisation connection For Synchronised operation between two Transmitters it is necessary to interconnect terminals 8 SYNC and 7 GND of terminal block MS1 on both Transmitters It is also necessary to select one Transmitter as Master and the other as Slave by means of jumper Jp3 e Jp3 IN position the terminal 8 of MS1 is the input for an external synchronisation signal so the Transmitter is Slave e Jp3 OUT position the terminal 8 of MS1 is the output for the internally produced synchronisation signal so the Transmitter is Master Remark Before connecting synchronization wires each barrier must be aligned individually Ensure that the transmitter of the barrier not being aligned is powered down The cable connecting the two transmitters must be as short as possible and not more than 10 meters If cables longer than 10 meters are required it is necessary to use the synchronisation repetition circui
8. 1 Transmitter Circuit Figure 8 Layout of connectors jumpers LEDs and presetting in transmitter board The following tables shows the connector pin functions present on MANTA Transmitter Term Symbol n 1 PT j Tamper relay contact Normally Closed bulb contact AMP1 2 PT2 Tamperrelay contact Normally Closed bulb contact AMP1 3 FLT1 Fault relay contact Normally Closed 4 FLT2 Fault relay contact Normally Closed 5 STBY Auxiliary input for Stand By command Norm Open from GND 6 TEST Auxiliary input for Test command Norm Open from GND Ground auxiliary connection 8 SYNC Sync In Out connection to perform Slave Master operation Term Symbol Function 1 13 8 Positive Dc Power Supply 13 8 V 2 GND 1 Negative Power Supply and Ground connection for Data 0 V 3 LH RS485 HighDataLine 4 LO RS485 LowDataline Installation Handbook page 33 of 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 TRANSMITTER CONNECTOR J1 10 pin Connector for local PC Serial Line connection Mwatest or WAVE TEST SW Symbol Function 1 2 4 N C Not Connected LO Low Line for RS 485 LH High Line for RS 485 E Power Supply 13 8 V Converter interface RS 485 232 LO LH TRANSMITTER CONNECTOR J2 Connector for MW oscillator DRO Term Symbol 1 Funct
9. 3 1 2 Circuito Ricevitore Figura 9 Disposizione topografica dei componenti nel circuito Rx Nelle seguenti tabelle sono indicate le funzioni delle morsettiere presenti sulla scheda MANTA RX MORSETTIERA MS1 RICEVITORE Simbolo Funzione ALL 1 Contatto Rel di Allarme C ALL 2 Contatto Rel di Allarme NC Contatto Rel di Manomissione C Ampolla AMP1 Contatto Rel di Manomissione NC Ampolla AMP1 ALI ALL2 STBY TEST GND C Contatto Rel di Guasto NC 7 ST BY Ingresso Ausiliario Comando Stand By Norm Aperto da GND 8 TEST Ingresso Ausiliario Comando TEST Norm Aperto da GND GND MORSETTIERA MS2 RICEVITORE 13 8V Ingresso Positivo di Alimentazione 13 8 V 13 8V ngresso Negativo per Alimentazione e per Dati 0 V RS 485 Linea Dati Alta RS 485 Linea Dati Bassa Manuale di Installazione Pagina 10 di 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 CONNETTORE J1 RICEVITORE Connettore 10 pin per collegamento locale PC Mwatest o WAVE TEST Mors Simbolo 1 2 4 N C Non Connesso soto S 3 4138 Alimentazione 13 8 V convertitore interfaccia RS 485 232 5 LO LineaBassaperRS485 7 LH LineaAltaperRS485 9 GND Massa CONNETTORE J2 RICEVITORE connettore per rivelatore a microonde Collegamento di Massa per Rivelatore a Microonde Collegamento per Rivelatore a Microonde Detector Collegamento di Massa per Riv
10. 4 3 Network Configuration and Signal Repeaters iii 40 3 53 REMOTE GONNECTIONs rt ere telis e 41 4 ADJUSTMENT AND TESTING ecieeeo cive so eta ee Genet Rana 42 4 1 ADJUSTMENT AND TESTING cei p s s n a n p p p nens asd 42 BLT Transmitter Set Up ros iit ebur p SHE eR Ee t Ode ter dpt et ed 42 4 1 2 Receiver Set Up snc i E ge DR ROTE EHE Ee DON E QE aa 42 4 2 ADJUSTMENT AND TESTING WITH SOFTWARE ccccccccccccscccecscecscececeeececeeseueueeeeeseusecususuaususesuauaueusuauauauauauauauauauauauauauanananena 46 5 MAINTENANCE AND ASSISTANCE eos ceas eee osae op e eua esee oth ase eer eee suusssescheseies soscisssssesesesstesssededesteuocssssbacddesesecsseseaseed 47 5 1 ROUBLESHOOTING A tees eue eret e LI cbe LA LI oves eb LIL A LOL Ete coc edel iti 47 5 2 MAINTENANCE KITS ici alii lana 47 6 CHARACTERISTICS C 48 6 T TECHNICAL CHARACTERISTICS LI p te EN III LL RL Luni 48 6 2 FUNCTIONAL CHARACTERISTICS nie zine nere rene rene nei ezine ene eee eee 49 APPENDIX A p 50 SCHEDA DI COLLAUDO TEST SHEET ai csssssccsssescsvisssssssscvesesssedeesdessacossuscb
11. 8 di 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 CONNETTORE J1 TRASMETTITORE Connettore 10 pin per collegamento locale PC Mwatest o WAVE TEST Mors Simbolo 1 2 4 N C Non Connesso FN 3 4138 Alimentazione 13 8 V convertitore interfaccia RS 485 232 5 LO LineaBassaperRS485 gt o _____ 9 GND 9 O CONNETTORE J2 TRASMETTITORE Connettore per oscillatore a microonde DRO Mors Simbolo _ 1 GND Collegamento di Massa per Oscillatore a MW 2 DRO Collegamento Frequenza Modulante per Oscillatore a MW 3 GND Collegamento di Massa per Oscillatore a MW SELETTORE CANALI DEL TRASMETTITORE Commutatore per la Selezione dei Canali di Modulazione SELETTORI NUMERO TRATTA TRASMETTITORE Simbolo Commutatore di Selezione del numero tratta decine DEV 1 Commutatore di Selezione del numero tratta unita LEDS DEL TRASMETTITORE ndicazione di Guasto ndicazione di Manomissione JUMPERS DEL TRASMETTITORE Default Terminazione Linea Seriale Jp1 posizione 1 2 terminazione NON inserita default Chiuso Abilitazione download FW Jp2 posizione 1 2 1 2 download FW NON abilitato default Chiuso Modulazione Interna Tx Master Sync Out Jp3 OUT posizione 2 3 o Esterna Tx Slave Sync In Jp3 2 3 posizione 1 2 Chiuso Manuale di Installazione Pagina 9 di 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2
12. Olgiate Molgora LC Via Don Sturzo n 17
13. V 42 bis Auto retrain disabled Error correction MNP Disable echo of controls Store parameters Load default parameters Engaged tone detection Remove compression MNP5 amp V 42 bis Auto retrain disabled Error correction MNP Automatic reply after one ring Disable echo of controls Store parameters page 50 of 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 56K Modem Centre at amp f Load default parameters atx3 Engaged tone detection at c3 Compression MNP5 amp V 42 bis at e0 Auto retrain disabled at ms 9 1 9600 9600 Make a connection only at 9600 bps at n3 Error correction V 42 LAPM MNP ate0 Disable echo of controls at amp w Store parameters Site at amp f Load default parameters atx3 Engaged tone detection at c3 Compression MNP5 amp V 42 bis at e0 Auto retrain disabled at ms 9 1 9600 9600 Make a connection only at 9600 bps at n3 Error correction V 42 LAPM MNP ats0 1 Automatic reply after one ring ate0 Disable echo of controls at amp w Store parameters Trust communicator 56K ESP Centre at amp f Load default parameters atx3 Engaged tone detection at c3 Compression MNP5 amp V 42 bis at e0 Auto retrain disabled at n3 Error correction V 42 LAPM MNP ate0 Disable echo of controls at amp w Store parameters Site at amp f Load default parameters atx3 Engaged tone detection at c3 Compression MNP5 amp V 42 bis at e0 Auto retrain disabled at n3 Error corre
14. electronic alignment phase is activated Push S3 button This action acquires the signal level and freezes the Automatic Gain Control after a few seconds In this condition the buzzer BZ1 produces a pulsed sound This means that the received field signal has reached the proper working level Gently unscrew the bracket screws and move the horizontal alignment of the receiver looking for the maximum received signal If during the alignment the pulse frequency of the buzzer increases this means that the received signal level is increased compared to the previous level In this case push the button S3 again and when the pulse frequency of the buzzer becomes lower proper working level move the head horizontally in the same direction If during the alignment the pulse frequency of the buzzer decreases this means that the received signal level is decreased compared to the previous level and so it is necessary to move back in the other horizontal direction to look for a better received signal If there is no new maximum level this means that the present horizontal alignment is the best position Installation Handbook page 42 of 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 f Gently unscrew the bracket screws of the transmitter and move the horizontal alignment looking for the maximum received signal on the receiver head as indicated in the previous point e When aligning the TX head it is possible to acquire the
15. heads will not change the alignment of the heads and so no re alignment is required Installation Handbook page 47 of 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 6 CHARACTERISTICS 6 1 Technical characteristics TECHNICAL GARACTERISTICS Win Nom Mer We Fey frese Free TT pese Fee Freni fisse Maximum power _ ZW sie Modulation __ ese Number of came TT CE S ES Rage TT MANTA 50 50m MANTO Current consumption TX in surveillance Current consumption TX in alarm 50 Curent consumption RX in suvellance mA Current consumption RX in alarm mA _ 5 muson alam contato Radome removal contaci XRX conta ERI eno Wwwsonaam RXjHedlEDOFF Notate Radome removal XsRX RedLEDOFF f o Moaie Fault alarm TX RX Red LED OFF P Not active Threshold adjustment On board SW 898 Deep brace mau WoWmtmemue 99 _ TTI Installation Handbook page 48 of 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 6 2 Functional Characteristics Signal processing according to behaviour models Absolute received signal va
16. il vertice piu opportuno dove collocare il Trasmettitore vicino al Ricevitore alcuni esempi sono illustrati in figura 1 ERRATO CORRETTO TX Figura 1 Manuale di Installazione Pagina 4 di 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 2 3 Condizioni del Terreno E sconsigliabile installare l apparato lungo tratti dove vi siano erba alta maggiore di 10 cm stagni corsi d acqua in senso longitudinale ed in generale tutti quei tipi di terreni la cui conformazione sia rapidamente variabile 2 4 Presenza di Ostacoli Le recinzioni se metalliche e pertanto molto riflettenti possono causare diversi problemi di riflessione della microonda quindi necessario adottare alcuni accorgimenti la recinzione deve essere accuratamente fissata in modo che il vento ne provochi il movimento dove possibile la tratta non deve essere installata in parallelo alla recinzione necessario creare un angolo rispetto ad essa nel caso in cui il fascio sensibile debba essere delimitato lateralmente da due reti metalliche consigliabile che il corridoio tra esse non sia inferiore ai 5 m in quanto il loro movimento potrebbe creare d
17. metri di portata Ci per facilitare il compito di chi chiamato ad effettuare l assistenza evitandogli l onere di disporre di 2 diversi kit secondo le portate In questo modo con un solo kit d assistenza l installatore non ha pi lonere di acquistare delle barriere complete per l assistenza ed inoltre rende pi semplice e rapida tale operazione La sostituzione della parte circuitale e della parte a microonda sia sul Trasmettitore sia sul Ricevitore non altera l orientamento della barriera e quindi non obbliga ad effettuare un nuovo puntamento Manuale di Installazione Pagina 23 di 51 MANTA 50 80 CIAS Elettronica S r l 6 CARATTERISTICHE 6 1 Caratteristiche Tecniche Ed 1 2 CARATTERISTICHE TECNICHE Nom Mer Noe Frequenza di lavoro F1 10 58 GHz Frequenza di lavoro F2 9 9 GHz Frequenza di lavoro F3 9 46 GHz Frequenza di lavoro F4 10 525 GHz Potenza massima 20mW 500 mW e i r p Modulazione Pulsato On off Duty cycle 50 50 Numero di canali a 16 Portata MANTA 50 50m Portata MANTA 80 80m Tensione d alimentazione V 11 5V 13 8 V 16V Corrente d alimentazione TX in vigilanza mA 80 Corrente d alimentazione TX in allarme mA 50 Corrente d alimentazione RX in vigilanza mA 58 Corrente d alimentazione RX in allarme mA 55 Contatto al
18. solo se anche l ampolla antisposizionamento AMPI risulta in posizione tale da fornire un contatto chiuso Verticale RELE di GUASTO 1 Tensione di Batteria Bassa lt 11V 2 Tensione di Batteria Alta gt 14 8V 3 Temperatura Bassa 35 C interna 4 Temperatura Alta gt 75 C interna 5 Guasto oscillatore BF bassa frequenza o RF radio frequenza circuito TX Nota 1 se il segnale di intrusione dopo aver superato la soglia di preallarme resta per 40 sec circa tra la medesima e la soglia di allarme viene generato un evento di allarme bersaglio fermo e si ha l attivazione del rel di allarme si apre il contatto Manuale di Installazione Pagina 13 di 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 3 3 2 Connessioni per Sincronismo Per effettuare il Sincronismo tra due Trasmettitori occorre connettere tra loro i morsetti 8 SYNC ed i morsetti 7 GND della morsettiera MS1 dei due Trasmettitori Inoltre necessario selezionare un Trasmettitore come Master e l altro come Slave mediante il ponticello Jp3 e Con Jp3 in posizione IN il morsetto 8 di MS1 il morsetto di ingresso per un sincronismo che proviene dall esterno pertanto il Trasmettitore cosi predisposto Slave e Con Jp3 in posizione OUT il morsetto 8 di MS1 il morsetto di uscita del segnale di sincronismo che viene prodotto all interno pertanto il Trasmettitore cosi predisposto Master N B Prima d
19. tratta del Fascio Sensibile in funzione della lunghezza della tratta nel caso di sensibilit massima e minima per i diversi modelli di apparecchio impiegati 10 Larghezza zona Sensibilita sensibile Massima 8 La met tratta m 7 6 5 4 3 Sensibilit minima 2 1 Lunghezza della tratta m 10 20 30 40 50 60 70 80 90 100 Figura 3 Larghezza della zona sensibile a met tratta per MANTA 50 80 In spazio libero 20 Altezza zona 18 sensibile Sensibilita 16 met tratta m Massima 14 12 10 8 6 Sensibilit 4 minima 2 Lunghezza della tratta m 10 20 30 40 50 60 70 80 90 100 Figura 4 Altezza della zona sensibile a met tratta per MANTA 50 80 In spazio libero Nota necessario ricordare che per l apparato MANTA la regolazione di sensibilit per ricavare la dimensione dei fasci sensibili a met della tratta determinata dalla regolazione delle soglie Quanto pi alte sono le soglie di preallarme e di allarme tanto pi bassa e la sensibilit e viceversa E inoltre importante ricordare che la soglia di preallarme determina il livello di inizio elaborazione cio tutti i segnali che stanno al di sotto di tale soglia sono
20. 0 94 PRESENCE OE OBSTACLES AIRIS ILL petet ce vie p Re o 30 2 5 DIMENSIONS OF THE SENSITIVE BEAM eee eee ete rtr ze r ceca nei eee eee 31 2 6 LENGTH OF THE DEAD ZONES NEAR THE Li 32 3 1 TERMINAL BLOCKS CONNECTORS AND CIRCUIT FUNCTIONS 0cc 33 TransmilterCIECUIHi iss nid qct nebst dd pi db lie id hh edad i ia dio 33 Sel 2 RECEIVE soc La alal 35 3 2 EQUIPMENT CONNECTION TO THE POWER SUPPLY iii 37 3 2 1 Connections to the Power Supply eec e mr ee EG RR RO ie 37 3 3 CONNECTIONS TO THE CONTROL PANEL einn neo n a a a EUR EE ETE eR Uer EXPERTO 38 3 3 1 Alarm contacts Alarm Tamper Fault iii 38 3 3 2 Synchronisation connection ensins a ep d be qa USUS da ES 39 3 3 3 Stand by connection nsa eee due eter ede es edge esae Liar RR IRSE eiue IRR 39 3 94 POSE CONNECHON orsus o e ea oh eA E Ea LM cel ne ab doi alla an ET etia 39 3 4 SERIATMIGINE RS 2485 inerenti ce rm ee este o ii cele dii ie o ii ue 40 3 4 1 RS 485 232 Network Connection Interface iii 40 3 4 2 RS 485 Serial Line connections ccccccccccccssssccceccccccssssccceccccccsssescecccessusseccececcsuuuseccececcuuuueseesececeauuaeseecscessuuaneesececeaes 40 3
21. 00 Altezza dal suolo Sensibilit Sensibilit 90 al centro Massima minima 90 go antenna 80 70 70 60 60 50 50 40 40 30 30 20 20 10 Lunghezza zona m 1 2 3 4 5 6 7 8 9 10 Figura 5 Lunghezza della zona morta in prossimit degli apparati in funzione dell altezza dal centro degli stessi al suolo per MANTA 50 80 80 85 E Figura 6 Lunghezza della zona morta in prossimit degli apparati in funzione dell altezza dal centro degli stessi al suolo per MANTA 50 80 Figura 7 Sovrapposizione di due fasci sensibili in un incrocio Manuale di Installazione Pagina 7 di 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 3 COLLEGAMENTI 3 1 Morsettiere connettori e Funzionalit dei Circuiti 3 1 1 Circuito Trasmettitore Figura 8 Disposizione topografica dei componenti nel circuito Tx Nelle seguenti tabelle sono indicate le funzioni delle morsettiere presenti sulla scheda MANTA TX MORSETTIERA MS1 TRASMETTITORE Simbolo Contatto Rel di Manomissione C Ampolla AMP1 Contatto Rel di Manomissione NC Ampolla AMP1 7 SYNC Uscita Ingresso del sincronismo per Tx Master Slave MORSETTIERA MS2 TRASMETTITORE Punioe o_o 13 8V Ingresso Positivo di Alimentazione 13 8 V 2 GND Ingresso Negativo per Alimentazione per Dati 0 V 3 LH 85485 Linea Dati Alta 4 LO RS485 Linea Dati Bassa Manuale di Installazione Pagina
22. 85 232 Sia il ricevitore che il trasmettitore della barriera MANTA sono dotati ciascuno di una interfaccia seriale standard RS 485 parametri di comunicazione sono i seguenti Modo Asincrono Half Duplex Velocit 9600 b s Lunghezza del carattere 8bit Controllo di parit Nessuno Bit di Stop 1 3 4 2 Connessioni per Linea Seriale RS 485 Il collegamento pu essere di tipo multidrop possono cio essere collegate pi barriere in parallelo alla stessa linea seriale configurazione Bus Tale connessione si effettua collegando sulla morsettiera MS2 del Ricevitore e del Trasmettitore il conduttore relativo ai dati della linea RS 485 negativi RS 485 al morsetto 4 LO il conduttore relativo ai dati della linea RS 485 positivi RS 485 al morsetto 3 LH il conduttore relativo al riferimento di massa dei dati al morsetto 2 GND Per collegare questa linea seriale al PC necessario utilizzare un convertitore RS 485 232 se il PC ha a disposizione una porta seriale RS232 oppure utilizzare il convertitore RS485 USB se il PC ha una porta USB Cavo per connettere circuiti di tutte le teste Rx e Tx al P C di manutenzione con SW WAVE TEST 2 Morsettiera Connettore 25 Morsettiera interfaccia pin D Type del Convertitore Pam sas EN BN E e por 13 8 V per convertitore 485 232 2 o 14 GND Massa dati per convertitore 485 232 3 2 LH485 LineadatiAltaperRS485
23. CA CON ene e ener nnn rene nere e e n 22 5 MANUTENZIONE E ASSISTENZA eoe ee seno to detenti re een aree eco rarae po sees soe ved va idrici e Rao eo euo oed P Ve 23 Sc LUBICGERCAI GUASTLD ace geet SA tetti tuas eei n ini SA iui 23 32 2 KIT ASSISTENZA Giulia ine ela allen o b eco pte ties 23 6 CARATTERISTICHE OE 24 CARATTERISTICHE TECNICHE rana anali 24 6 2 CARATTERISTICHE F NZIONALI center I t beet eae tr RI E I a ee ue tenes 25 APPENDICE A risa 26 Manuale di Installazione Pagina 1 di 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 1 DESCRIPTION m P 28 CT 28 2 INSTALLATION eeu reae da eae eu Vo eR ee aC 28 2 1 PRELIMINARY INFORMATION etete S r r r r r r r r 28 2 2 NUMBER OR SECTIONS 29 2 2 GROUND CONDITIONS Rot 3
24. D8 and D9 will turn off and the buzzer will BEEP The number of beeps indicate the quality of the alignment The following table shows the relationship between the number of beeps and the quality of the alignment 1 Beep z Excellent 2 beep Good 3 Beep Poor 4 Beep Insufficient 5 or more Beep No Alignment If the alignment quality is poor or worse repeat the alignment operations and verify that nothing is within the microwave beam k Select position 3 on the function switch SW1 The pre alarm thresholds adjustment phase is activated The two pre alarm thresholds are set above and below the quiescent field value The analysis process begins when the field value exceeds one of them If the field value remains between the pre alarm and the alarm threshold continuously for about 40 seconds a pre alarm event is generated and the alarm relay is activated To read the current pre alarm threshold value proceed as follows e Rotate decimal switch SW2 tens column until the second red led D9 comes ON e Rotate decimal switch SW3 units column until the first red led D8 comes ON The values read will be between 01 and 80 default value 15 Decreasing the threshold value increases the sensitivity and the sensitive beam dimensions To modify the current value and increase the sensitivity it is necessary to select using the two switches SW3 and SW2 a lower value and then push the button S3 To decrease the sensitivity it is neces
25. ERMO 482 X barrier it is possible to select a different barrier number for each receiver installed in the specific site This allows different barriers to communicate using the same bus To read the present barrier number proceed as follows e Rotate decimal switch SW2 tens column until the second red led D9 comes ON e Rotate decimal switch SW3 units column until the first red led D8 comes ON The values read will be between 01 and 99 Value 00 means barrier 100 and this is the default value used when a fatal error occurs and the default parameters are automatically used To modify the current barrier number it is necessary to select using the two switches SW3 and SW2 a new value and then push the button S3 Select position 9 on the function switch SW1 The monitor threshold adjustment phase is activated The two monitor thresholds are set above and below the quiescent field value The storage of the signal received begins when the field value exceeds one of them To read the current monitor threshold value proceed as follows e Rotate decimal switch SW2 tens column until the second red led D9 comes ON e Rotate decimal switch SW3 units column until the first red led D8 comes ON The values read will be between 01 and 80 default value 15 Decreasing the threshold value means that the recording starts when weaker signals are received To modify the current value and increase the sensitivity weaker signal it is necessary to s
26. ONE UTILIZZATO H x MODULATION CHANNEL USED O chi cho Ch9 che Och2 Ocha Ch3 OchB Ochs Ch4 ChC Ch4 che Ochs Ocho Ochs Ocho che Oche che Oche O Ch7 ChF Ch7 ChF OSSERVAZIONI DELL INSTALLATORE INSTALLER COMMENTS Data installazione Installation date Firma Installatore Installer Signature tr T 6 tt lt NOTE Con la presente CIAS Elettronica dichiara che questo rivelatore di intrusione MANTA conforme ai requisiti essenziali ed alle altre disposizioni rilevanti della Direttiva 1999 5 CE Art 3 14 3 1p 3 2 Hereby CIAS Elettronica declares that this movement detector MANTA is in compliance with the essential requirement and other relevant provisions of Directive 1999 5 EC Art 3 14 3 1p 3 2 e Informazioni direttive Europee WEEE Questo apparecchio contrassegnato in conformit alla Direttiva Europea 2002 96 EC Waste Electrical and Electronic Equipment WEEE Assicurandosi che questo prodotto sia smaltito in modo corretto l utente contribuisce a prevenire le potenziali conseguenze negative per l ambiente e la salute Il simbolo Mm sul prodotto o sulla documentazione d accompagnamento indica che questo prodotto non deve essere trattato come rifiuto domestico ma deve essere consegnato presso l idoneo punto di raccolta per il riciclaggio d apparecchi
27. STD Posizione 8 Lettura scrittura Numero Tratta Posizione 9 Lettura scrittura soglie di monitor Posizione 0 Fase di lavoro SELETTORI LETTURA SCRITTURA PARAMETRI E NUMERO BARRIERA DEL RICEVITORE N Simbolo Funzione 4 O DEV10 Commutatore decimale per lettura o impostazione dei parametri durante le fasi di allineamento decine SW3 DEV1 Commutatore decimale per lettura o impostazione dei parametri durante le fasi di allineamento unit PUNTI DI MISURA DEL RICEVITORE N Simbolo Funzione 4 TP4 Segnale 200mVpp 8 TP8 NegativoperMisura Massa 9 Tensione del controllo automatico di guadagno RAG 3 2 Collegamento all Alimentazione Principale 3 2 1 Collegamento all Alimentazione Entrambe le unit Tx ed Rx devono essere alimentate in corrente continua alla tensione nominale di 13 8 V Il collegamento tra l alimentatore e la testa deve essere adeguatamente dimensionato quindi la sezione del conduttore deve essere calcolata in base alla lunghezza del collegamento ed all assorbimento degli apparati Nel caso in cui i collegamenti risultassero troppo lunghi si consiglia l utilizzo di un alimentatore supplementare Connettere i fili di alimentazione continua 13 8 V e GND rispettivamente ai morsetti 1 e 2 della morsettiera MS2 sia del circuito Tx che del circuito Rx Il cavo che porta l alimentazione all apparecchiatura deve essere schermato e lo schermo deve essere collegato a terra Manu
28. TEST or WAVE TEST for tests setting and management of barrier Installation Handbook page 49 of 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 APPENDIX A The following is a list of the settings of some modems needed to remotely connect the barriers As it can be seen 2 different settings are provided for each type of modem i e CENTRE Operator Terminal which remotely connects the MANTA Barriers and SITE the RS485 interconnection network of the MANTA Barriers Digicom Botticelli 56K V 90 Centre at amp f atx3 at c3 at e0 at ms 9 1 9600 9600 at n3 ate0 at amp w Site at amp f atx3 at c3 at e0 at ms 9 1 9600 9600 at n3 ate0 ats0 1 at amp w VACF1433VQE Centre at amp f atx3 at c0 at e0 at n5 ate0 at amp w Site at amp f atx3 at c0 at e0 at n5 ats0 1 ate0 at amp w Installation Handbook Digicom Leonardo56 Load default parameters Engaged tone detection Compression MNP5 amp V 42 bis Auto retrain disabled Make the connection only at 9600 bps Error correction V 42 LAPM MNP Disable echo of controls Store parameters Load default parameters Engaged tone detection Compression MNP5 amp V 42 bis Auto retrain disabled Make the connection only at 9600 bps Error correction V 42 LAPM MNP Disable echo of controls Automatic reply after one ring Store parameters Load default parameters Engaged tone detection Remove compression MNP5 amp
29. a 850mm 300mm TRONCHETTI RADIALI ANTIROTAZIONE PALO BASAMENTO INTERRATO IN CEMENTO TUBAZIONE PER INGRESSO Antenna Palo da Parete 40 mm Manuale di Installazione CAVI DAIMPIANTO Antenna 450 mm Nit Palo da pd iL LU Jl gt Foro per uscita cavi da impianto sotto PARETE TUBAZIONE PER INGRESSO ZII CAVI DA IMPIANTO Pagina 3 di 51 PARETE MANTA 50 80 CIAS Elettronica S r l Ed 1 2 2 2 Numero di Tratte Dovendo progettare la protezione con barriere volumetriche di un perimetro chiuso oltre alle normali considerazioni di suddivisione del perimetro in un certo numero di tratte che tengano conto delle necessit gestionali dell intero impianto occorre ricordare che sempre preferibile installare un numero di tratte pari Questa considerazione legata al fatto che le possibili interferenze reciproche tra tratte contigue vengono annullate nel caso in cui ai vertici Incroci del poligono risultante dall installazione stessa vengano installati due teste dello stesso genere cio due trasmettitori o due ricevitori E evidente che ci pu avvenire solo nel caso che il numero delle tratte sia pari Qualora non fosse possibile disporne in numero pari occorrer fare alcune attente considerazioni sulle possibili interferenze in modo che possa essere correttamente scelto
30. ale di Installazione Pagina 12 di 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 3 3 Collegamento alla Centrale Le connessioni alla Centrale di elaborazione devono essere effettuate mediante cavi schermati 3 3 1 Contatti di allarme Allarme Guasto Manomissione Le uscite degli apparati sono costituite per il TX da 2 contatti di rele normalmente chiusi liberi da potenziale mentre per RX i contatti sono 3 essi sono adibiti alla segnalazione dei seguenti stati e ALLARME RX e MANOMISSIONE RX e TX e GUASTO RX e TX Sono inoltre presenti 3 Ingressi per attuare le seguenti funzioni e Test TX e RX e Stand by TX e RX e Sincronismo solo TX contatti di uscita per allarme manomissione e guasto sia sul Trasmettitore sia sul Ricevitore sono costituiti da Rel statici con una portata di 100 mA max N B i contatti di Allarme Manomissione e Guasto presentano in stato di Vigilanza contatto chiuso una resistenza di circa 40 Ohm contatti d allarme sono attivati per i seguenti motivi RELE di ALLARME 1 Allarme bersaglio fermo sul Ricevitore Nota 1 2 Allarme Intrusione su Ricevitore 3 Allarme mascheramento su Ricevitore 4 Risultato Positivo dell esecuzione di una procedura di Test su Ricevitore 5 Segnale ricevuto insufficiente V RAG gt 6 99V 6 Allarme canale RELE di MANOMISSIONE 1 Rimozione del coperchio Radome 2 Sposizionamento Ampolla NB La chiusura del contatto di manomissione avverr
31. asso dell attuale soglia Se si desidera diminuire la sensibilit impostare un valore pi alto Durante questa fase SW1 in posizione 4 possibile effettuare il Walk Test infatti la barriera funziona con i parametri impostati ed ogni perturbazione variazione del segnale a microonde Fascio sensibile d luogo all attivazione del Buzzer che si trova a bordo della scheda del ricevitore Il suono del buzzer intermittente la frequenza dell intermittenza dipende dalla intensit del segnale perturbante se la frequenza cresce significa che il segnale perturbante cresciuto quindi indica una maggiore penetrazione dell intruso nel campo di protezione se il segnale perturbante raggiunge le condizioni per determinare un evento di allarme il buzzer verr attivato con un suono continuo In questo modo possibile valutare la reale consistenza del fascio sensibile ed anche verificare se presunte fonti di disturbo Per esempio recinzioni non ben fissate o altro influiscono realmente sulla protezione ed in che misura m Portando il commutatore di funzione SW1 in posizione 5 possibile leggere e o modificare n il valore delle soglie di mascheramento superiore ed inferiore Le soglie di mascheramento sono poste una sopra ed una sotto il valore di campo memorizzato durante la fase di acquisizione j Esse determinano se durante il funzionamento avvengono variazioni del campo ricevuto che possano provocare una alterazione de
32. atore di funzione SW1 in posizione 9 possibile leggere e o modificare il valore delle soglie di monitor superiore ed inferiore Le soglie di monitor sono poste una sopra il valore di riposo del segnale ricevuto ed una sotto Esse servono a determinare l inizio della memorizzazione del segnale ricevuto Quando una di queste due soglie viene superata dalla variazione del segnale ricevuto inizia la memorizzazione Lettura del valore attuale delle soglie di monitor e ruotare il commutatore SW2 decine fino a che il primo led rosso 09 sia acceso e ruotare il commutatore SW3 unit fino a che il secondo led rosso D8 sia acceso Il valore letto su questi due commutatori varia da 01 a 80 Il valore di default 15 Modifica del valore attuale delle soglie di monitor e ruotare commutatori SW2 decine e SW3 unit sul valore desiderato e premere 53 per confermare l acquisizione la messa in uso delle nuove soglie Pi basso questo valore maggiore la sensibilit e quindi pi deboli i segnali che determinano la memorizzazione Se si desidera aumentare la sensibilit impostare un valore pi basso dell attuale soglia Se si desidera diminuire la sensibilit impostare un valore pi alto r Ruotare il commutatore di funzione SW1 in posizione 0 e premere il pulsante S3 Questa operazione conclude tutte le fasi di installazione della barriera memorizza le soglie selezionate e messe in uso nelle fasi precedenti NB Se la bar
33. ature elettriche ed elettroniche e Disfarsene seguendo le normative locali per lo smaltimento rifiuti Lo smaltimento abusivo punito con le sanzioni previste dalla legislazione nazionale vigente e Il prodotto pu essere riconsegnato al distributore installatore a fine vita in occasione di un nuovo acquisto This product is marked in compliance with the European Directive 2002 96 EC Waste Electrical and Electronic Equipment WEEE The correct disposal of the product will prevent potential negative consequences for the environment and the human health A The symbol on the product or into the annexed documentation indicates that this product does not have to be dealt like domestic refusal but must be delivered near the suitable point of collection for the recycling of electrical and electronic equipment e The illicit disposal will be endorsed according to local regulations e Atthe end of operative life the product can be given back to the vendor installation organization in occasion of a new purchase Copyright CIAS Elettronica S r l Stampato in Italia Printed in Italy CIAS Elettronica S r l Direzione Ufficio Amministrativo Ufficio Commerciale Laboratorio di Ricerca e Sviluppo Direction Administrative Office Sales Office Laboratory of Research and Development 20158 Milano via Durando n 38 Tel 39 02 376716 1 Fax 39 02 39311225 Web site www cias it E mail info cias it Stabilimento Factory 23887
34. azioni sul Ricevitore Per togliere il radome coperchio frontale svitare le 3 viti fintanto che esse non girano a vuoto Allontanare il radome dal fondo questa operazione provochera l apertura del microinterruttore Tamper presente sul PCB Connettere i fili di alimentazione continua 13 8 V ai morsetti 1 e 2 di MS2 Fig 9 Per ottimizzare l allineamento della barriera ed impostare i parametri senza l ausilio di alcuno strumento utilizzando il sistema elettronico integrato dopo un primo allineamento ottico procedere nel seguente modo a Assicurarsi che il microinterruttore di controllo apertura del coperchio S2 sia aperto b Ruotare il commutatore di funzione SW1 in posizione 1 Questa operazione attiva la fase di installazione della barriera c Premere il pulsante S3 Tale operazione attiver il sistema di regolazione rapida del segnale ricevuto Dopo qualche secondo il sistema di regolazione rapida del segnale si arresta ed il Buzzer BZ1 emetter un suono intermittente ad indicare che il segnale ha raggiunto il corretto livello di lavoro d Allentare le viti di fissaggio al palo agire sull orientamento orizzontale della testa ricevente in modo da ricercare il valore massimo di segnale e Se durante l orientamento la frequenza del suono intermittente cresce significa che il segnale ricevuto aumentato rispetto alla situazione precedente Premere nuovamente il pulsante S3 e quando la frequenza del suono intermit
35. ble Connect to terminal 4 LO RS 485 negative data line to terminal 3 LH RS 485 positive data line and to terminal 2 GND data ground line on terminal block MS2 on the Receiver and Transmitter PCB To connect this serial line to a PC it is necessary to use an RS 485 232 convertor if the PC has an RS232 port available or an RS485 USB convertor if it has a USB port Cable for connecting the barriers To a maintenance P C with WAVE TEST 2 SW Interface 25 pin RS485 USB Terminals Connector Convertor MS2 D Type of Terminals the convertor Nw Nw N Symbol 1 12 4138 Power 13 8 V for 485 232 convertor 2 1 GND Data power ground 485 232 convertor 10 2 LH485 Line High for RS 485 __4 11 3 0485 Data Line Low for RS 485 3 4 3 Network Configuration and Signal Repeaters The interconnection cable for barrier management via a remote P C must be suitable for a RS485 serial data line i e it must be a low capacity cable with twisted and shielded wires 70 pF mt for example Belden 9842 The limit distance for the RS 485 connection is 1200 meters For longer distances use one or more interface Regenerators BUS REP see figure below The cable configuration must be of the BUS type and the branches for connection of the units as short as possible It is possible to configure the cable in different ways full star mixed star and BUS type using Repeat
36. che provoca sul ricevitore l attivazione del rel di allarme in caso di risultato positivo sul ricevitore di tre uscite a rel statico per allarme manomissione e guasto e sul trasmettitore di due uscite a rel statico per manomissione e guasto sul ricevitore di tre leds di segnalazione allarme manomissione guasto e sul trasmettitore di due leds di segnalazione manomissione guasto sul trasmettitore di un segnale di uscita con funzione di sincronismo per altri trasmettitori che possano interferire tra loro 14 Disponibilit sul trasmettitore di un ingresso di sincronismo proveniente da un altro trasmettitore che possa interferire 15 Disponibilit sul trasmettitore di un commutatore a 16 posizioni che consente di stabilire quale canale di modulazione utilizzare 1 ricevitore durante la fase di installazione riconosce e memorizza automaticamente quale canale deve essere utilizzato durante la fase di lavoro 16 sul ricevitore e sul trasmettitore di un Supercap che consente il funzionamento dell orologio datario RTC anche in assenza totale di alimentazione 17 Disponibilit sul ricevitore e sul trasmettitore di un orologio calendario che consente di fornire una marcatura temporale agli eventi che sono registrati sia dal monitor degli eventi analogici RX che storico degli eventi RX TX 18 Disponibilit sul ricevitore e sul trasmettitore di un archivio storico degli eventi in grado di re
37. considerati disturbo o rumore Tutti i segnali che superano questa soglia danno luogo alla elaborazione del segnale secondo le regole Fuzzy previste Se dopo aver superato la soglia di preallarme il segnale di intrusione resta per circa 40 sec tra la medesima e la soglia di allarme viene generato un evento di preallarme e si ha l attivazione del rel di allarme Le soglie di preallarme di allarme e quindi la sensibilit sono regolabili sia mediante i dispositivi integrati a bordo di ciascuna unit ricevente sia mediante il Software WAVE TEST Le impostazioni di default sono relative ad una sensibilit media adatta alla gran parte dei casi pratici Manuale di Installazione Pagina 6 di 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 2 6 Lunghezza delle Zone Morte in prossimit degli apparati La lunghezza delle Zone Morte in prossimit degli apparati in funzione sia della distanza dell apparato stesso dal suolo sia della sensibilit impostata sul Ricevitore figura 5 L Altezza consigliata per installazioni standard di 85 cm circa compatibilmente con le esigenze impiantistiche La misura da considerarsi tra il suolo e il centro dell antenna Con una sensibilit media default la distanza minima consigliata per effettuare l Incrocio di 3 5 m 100 na ez
38. ct one of the 16 modulation channel available using the hexadecimal switch between 0 and F To increase the resistance to tampering it is a good idea to preset different channels for the different barriers installed on the same site The use of different channels does not affect the detection ability of the barrier e Remark if one RX receives a MW signal from its own transmitter and from another interfering transmitter for example due to reflections or any other field reason it is necessary to synchronize the two transmitters selecting one as Master and the other as Slave In this case the modulation channel for the slave transmitter is the same as selected on the Master regardless its own selection Before connecting synchronization wires each barrier must be aligned individually Ensure that the transmitter of the barrier not being aligned is powered down e Itis possible to address each Transmitter Head using switches SW2 SW3 e How address the TX head simply select a number between 01 and 99 00 means barrier 100 using the two rotary switches SW3 units column and SW2 tens column 4 1 2 Receiver Set up To remove the radome unscrew the 3 screws until loose then release them gently without removing them completely Check the D C power voltage 13 8 at terminals 1 and 2 on terminal block MS2 Fig 9 Ensure that the tamper switch S2 is activated Open circuit Select position 1 on the function switch SW1 The
39. ction V 42 LAPM MNP ats0 1 Automatic reply after one ring ate0 Disable echo of controls at amp w Store parameters MODEM CIAS 9600 Site at amp f Load default parameters ats0 1 Automatic reply after one ring 0 No compression MNP5 amp V 42 bis at e0 Auto retrain disabled at n5 Error correction MNP ate0 Disable echo of controls at amp w Store parameters Note the CIAS 485 9600 modem accepts the serial line RS485 without the cable crossover connections and the RS485 RS232 conversion Installation Handbook page 51 of 51 MANTA 50 80 SCHEDA DI COLLAUDO TEST SHEET MANTA TX Cliente Customer Indirizzo Address Barriera Barrier N NUMERO DI SERIE SERIAL NUMBER VALORI MISURATI SUL TRASMETTITORE MEASURED VALUES ON THE TRASMITTER MISURE MEASUREMENTS VALORI TIPICI STANDARD VALUES VALORI MISURATI MEASURED VALUES INSTALLAZIONE MANUTENZIONE INSTALLATION MAINTENANCE TENSIONE DI ALIMENTAZIONE MISURATA TRA I PIN 1 2 DI MS2 SUPPLY VOLTAGE MEASURED BETWEEN PINS 1 2 OF MS2 13 8 VDC 10 TENSIONE DI ALIMENTAZIONE INTERNA MISURATA TRA TP3 E GND INSIDE SUPPLY VOLTAGE MEASURED BETWEEN TP3 AND GND 5 10 TENSIONE DI ALIMENTAZIONE INTERNA MISURATA TRA TP4 E GND INSIDE SUPPLY VOLTAGE MEASURED BETWEEN 8 VDC 10
40. d a maximum of 32 devices including the BUSREP can be connected to each one The first section includes the seriale line converter SERIAL LINE CONVERTER RS 485 RS 232 BUSREP 1 BUSREP 2 L2 EN 3 EL EI ds Field Field Devices Devices Devices L4 The figure shows a system which requires a RS 485 serial line that is longer than 1 200 metres Using two BUSREPs as regenerators it was divided up into 3 sections each of which was shorter in length In this case there are less than 32 field devices but they can be distributed on 3 600 metres long line 3 5 Remote Connection To interface MANTA barrier to PSTN modem 9600 b s it is necessary to convert RS485 to RS232 and also make the cross over shown below 485 232 MODEM DB25M DB25M Installation Handbook page 41 of 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 4 ADJUSTMENT AND TESTING 4 1 Adjustment and Testing A built in electronic alignment parameter set and test tool is provided in the receiver head of the MANTA barrier This is a very useful system both for installation and periodical maintenance 4 1 1 Transmitter Set up e To remove the radome unscrew the 3 screws until loose then release them gently without removing them completely e Check the D C power voltage 13 8V at terminals 1 and 2 on terminal block MS2 Fig 8 e Sele
41. e e ruotare il commutatore SW2 decine fino a che il led rosso 09 sia acceso e ruotare il commutatore SW3 unit fino a che il led rosso D8 sia acceso Il valore letto su questi due commutatori varia da 01 a 80 Valore di default 30 Modifica del valore attuale delle soglie di allarme superiore e ruotare commutatori SW2 decine e SW3 unit sul valore desiderato e premere 53 per confermare l acquisizione e la messa in uso delle nuove soglie Per la corretta attivazione della funzione FSTD necessario innalzare sia il valore della soglia di preallarme superiore sia il valore della soglia di allarme superiore p Portando il commutatore di funzione SW1 in posizione 8 possibile leggere e o impostare il N di tratta Modifica scrittura del numero di tratta e selezionare un numero da 1 a 99 sugli appositi commutatori SW2 decine e SW3 unit L impostazione 00 corrisponde alla tratta 100 e premere il pulsante S3 per confermarne l acquisizione e la messa in uso Lettura del numero di tratta assegnata e ruotare il commutatore SW fintanto che il led rosso 09 sia acceso e ruotare il commutatore SW3 fintanto che il led rosso D8 sia acceso Il numero da 01 a 99 rappresentato sui commutatori SW2 decine e SWS unit corrisponde al numero di tratta attualmente assegnato alla barriera Il numero 00 significa che si verificato un errore e sono stati ripristinati i parametri dei default q Portando il commut
42. e between 01 and 80 default value 15 and it is the same as set at point k Increasing the upper pre alarm threshold value decreases the side sensitivity as in the side beam dimensions To modify the current value and decrease the side sensitivity it is necessary to select using the two switches SW3 and SW2 a higher value and then push the button S3 Select position 7 on the function switch SW1 The upper alarm threshold adjustment phase is activated As described in previous point n to activate the Fuzzy Side Target Discrimination FSTD system it is also necessary to increase the upper alarm threshold generally by the same amount as in previous point n To read the current upper alarm threshold value proceed as follows e Rotate decimal switch SW2 tens column until the second red led D9 comes ON e Rotate decimal switch SW3 units column until the first red led D8 comes ON The values read will be between 01 and 80 default value 30 and it is the same as set at point k Increasing the higher alarm threshold value decreases the side sensitivity as in the side beam dimensions To modify the current value and decrease the side sensitivity it is necessary to select using the two switches SW3 and SW2 a higher value and then push the button S3 Select position 8 on the function switch SW1 The barrier number selection phase is activated To communicate by the standard RS 485 serial interface provided on receiver of the
43. e compresa tra 0 e F L utilizzo di un canale di modulazione piuttosto di un altro non altera il funzionamento della barriera per buona norma predisporre canali differenti per le differenti barriere di un impianto in modo da accrescerne le doti di insabotabilit e qualora vi fosse la probabilit che due barriere si interferiscano reciprocamente perch i segnali a MW dell una possono per ragioni impiantistiche essere intercettati dall altra si render necessario sincronizzare gli apparati trasmittenti facendo in modo che uno dei due Master fornisca all altro Slave il segnale di sincronismo In questo caso la frequenza di modulazione del Trasmettitore Slave non dipendera dalla posizione del proprio commutatore ma solo dal segnale di sincronismo Prima di effettuare le operazioni di sincronismo necessario allineare ogni singola barriera avendo cura di disalimentare il trasmettitore non interessato e Per ogni testa TX possibile assegnare l appartenenza ad una specifica tratta mediante i commutatori SW2 e SW3 e Assegnazione scrittura del numero di tratta e selezionare un numero da 01 a 99 sugli appositi commutatori SW3 unit e SW2 decine L impostazione 00 corrisponde alla tratta 100 e Lettura del numero di tratta assegnata sufficiente leggere l impostazione sui commutatori SW2 e SW3 del trasmettitore Manuale di Installazione Pagina 17 di 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 4 1 2 Oper
44. ection connect 13 8 Vdc and GND to pin 1 and 2 on the terminal block MS2 of the Tx and Rx circuits Installation Handbook page 37 of 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 3 3 Connections to the Control Panel 3 3 1 Alarm contacts Alarm Tamper Fault On the transmitter PCB there are 2 relays and on the receiver PCB there are 3 relays These relays are normally closed static dry contacts Using these contacts it is possible to communicate the following conditions to the control panel e ALARM RX e TAMPER RX and TX e FAULT RX and TX There are also 3 inputs to activate the following functions e Test TX and RX e Stand by TX and RX e Synchronism only TX The output contacts for alarm tamper and fault both on transmitter and receiver are Static Relays with maximum current of 100 mA Remark in closed condition the resistance of these contacts is about 40 ohm The connections to control panel must be made using shielded cables The relays are activated for the following reasons ALARM RELAYS 1 Stopped target alarm on receiver Remark1 2 Intrusion alarm on receiver 3 Receiver masking condition alarm 4 Successful result of test procedure operation on receiver 5 Insufficient received signal V RAG gt 6 99V 6 Channel alarm TAMPER RELAYS 1 Removal of Cover radome TX and RX 2 Tilt Switch position TX and RX FAULT RELAYS 1 Battery voltage low lt 11V 2 Battery voltage high
45. ei disturbi in caso contrario contattare l assistenza tecnica CIAS recinzioni metalliche poste dietro gli apparati possono provocare talvolta distorsioni del fascio sensibile e quindi dare luogo a falsi allarmi Gli alberi le siepi i cespugli la vegetazione in genere richiede una grande attenzione qualora ve ne sia in prossimit o entro i fasci di protezione Questi ostacoli sono elementi variabili sia come dimensione che come posizione possono infatti crescere ed essere mossi dal vento Figura 2 Pertanto sconsigliabile tollerare la presenza di detti ostacoli entro le tratte di protezione E possibile tollerarne la presenza solo a patto che la loro crescita venga limitata mediante una metodica manutenzione e che il loro movimento venga inibito mediante barriere di contenimento All interno del fascio di protezione e altresi tollerabile la presenza di tubi pali ed Ostacoli vari illuminazione camini ecc purch non presentino dimensioni eccessive all interno dei lobi di protezione Questi infatti sono la causa di Zone d Ombra non protette e di Zone di Ipersensibilit fonti di falsi allarmi Manuale di Installazione Pagina 5 di 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 2 5 Ampiezza dei Fasci Sensibili L ampiezza del Campo Sensibile in funzione sia della distanza tra Trasmettitore e Ricevitore sia dalla regolazione di sensibilit impostata Le figure seguenti ci forniscono il diametro a met
46. elatore a Microonde CONNETTORE J7 RICEVITORE Connettore per Buzzer Supplementare Simbolo Funzione Comando per buzzer supplementare Alimentazione per buzzer supplementare 13 8 V Alimentazione per buzzer supplementare 13 8 V Default Terminazione Linea Seriale Jp1 posizione 1 2 1 2 terminazione NON inserita default Chiuso Abilitazione download FW Jp2 posizione 2 3 2 3 download FW NON abilitato default Chiuso LEDS DEL RICEVITORE Simbolo D12 Indicazione di Alarme 11 OF 011 Indicazione di Manomissione OFF D10 Indicazione di Guasto OF 09 _ Funzioni Allineamento e Regolazione OFF 08 _ Funzioni Allineamento e Regolazione OFF Manuale di Installazione Pagina 11 di 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 PULSANTE DI CONFERMA ALLINEAMENTO REGOLAZIONI N Simbolo X Funzione X Attivazione conferma scrittura acquisizione fase di allineamento regolazione SELETTORE DI FUNZIONI SUL RICEVITORE Posizione 1 Allineamento Barriera Posizione 2 Acquisizione Canale e valore di campo Posizione 3 Lettura scrittura soglie di preallarme Posizione 4 Lettura scrittura soglie di allarme Walk Test Posizione 5 Lettura scrittura soglie di Mascheramento Posizione 6 Lettura scrittura soglia di preallarme sup FSTD Posizione 7 Lettura scrittura soglia allarme superiore F
47. elect using the two switches SW3 and SW2 a lower value and then push the button S3 To decrease the sensitivity stronger signal it is necessary to select using the two switches SW3 and SW2 a higher value and then push the button S3 Select position 0 on the function switch SW1 and then push the button S3 This operation stores the parameters selected in the previous steps Installation Handbook page 45 of 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 4 2 Adjustment and Testing with Software Use a PC with MWATEST or WAVE TEST CIAS programs to view and manage all the software parameters of the barrier including the analogue levels of the thresholds and of the received signal The connections and or software management functions are specified in the technical documentation for the program Connessione Stop Agg Stato Server Tempo Totale Schermo Tempo Trascorso Impianto Centrale Nucleare Svedese Dispositivo 1 Manta RX MAR2 01 09 07 mR Server Disconnesso COM 3 03 10 2007 12 04 36 5367 mV Installation Handbook page 46 of 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 5 MAINTENANCE AND ASSISTANCE 5 1 Troubleshooting In case of false alarms check the parameters recorded during the Installation phase on attached Test Sheet if there are differences outside the permitted limits check the related points in chapter Adjustment and Testing 4 again Possib
48. ensitive beam causes the activation of a pulsed sound produced by the on board buzzer The pulse frequency is proportional to the level change of the received microwave signal If the pulse frequency increases it means that the level change of the received microwave signal has increased and therefore that the intruder has penetrated more deeply into the protection beam If an alarm event is generated at the end of the analysis process the sound of the buzzer becomes continuous not pulsed This allows the actual dimensions of the protection beam to be checked and also to verify if something is moving in the protected area such as poorly constructed or maintained fences that can cause problems m Select position 5 on the function switch SW1 The masking thresholds adjustment phase is activated The two masking thresholds are set above and below the absolute installation field value VRAG memorized during the phase 2 see previous point j They are used to check if changes in the received absolute microwave field are large enough to decrease or eliminate the detection ability of the barrier A thick layer of snow can produce this kind of change but someone can try to produce them intentionally in order to mask the receiver To read the current masking threshold values proceed as follows e Rotate decimal switch SW2 tens column until the second red led D9 comes ON e Rotate decimal switch SW3 units column until the first red led D8 com
49. eossesiaedevecdsesadesseesesdestesoessssusedecsdescss 0 SCHEDA DI COLLAUDO TEST SHEET rre sccvcesscstvesvecsosseecesaveesssesvccssosteetessdusdcessdivesss sanvcsdscsdessbadsucdsessssvseescsvsvecesveus 1 Manuale di Installazione Pagina 2 di 51 MANTA 50 80 CIAS Elettronica S r l 1 DESCRIZIONE 1 1 Descrizione Ed 1 2 MANTA una barriera digitale a microonde di CIAS per protezione volumetrica interna ed esterna Il suddetto sistema in grado di rilevare la presenza di un corpo che si muove all interno di un campo sensibile instauratosi tra il Trasmettitore TX e il Ricevitore RX segnale ricevuto viene analizzato digitalmente attraverso i metodi della logica Fuzzy permettendo di raggiungere eccellenti prestazioni nella rilevazione e la diminuzione dei Falsi Allarmi MANTA disponibile con le seguenti portate MANTA 50 Portata 50 metri MANTA 80 Portata 80 metri 2 INSTALLAZIONE 2 1 Informazioni preliminari La barriera MANTA permette di ottimizzare l installazione in base alle esigenze dell utente Svitando lo snodo e ruotandolo con il foro di accesso cavi rivolto verso l alto possibile effettuare il montaggio a parete Di seguito sono riportate le indicazioni per i diversi modi di installazione FORO PER USCITA CAVI DAIMPIANTO Palo da interrare 40 mm Antenna Palo da Pavimento 40 mi 0mm N ALTEZZA DAL SUOLO CONSIGLIATA 800 mm da 750
50. ep Qualita Pessima Qualora la qualit dell allineamento risulti scarsa o peggio ripetere tutta la procedura di allineamento accertandosi che non vi siano ostacoli o disturbi nel campo di protezione ritornare quindi in questa fase e premere nuovamente il pulsante S3 k Portando il commutatore di funzione SW1 in posizione 3 possibile leggere e o modificare il valore delle soglie di preallarme superiore ed inferiore Le soglie di preallarme sono poste una sopra il valore di riposo del segnale ricevuto ed una sotto Esse servono a determinare l inizio del processo di analisi del segnale ricevuto Quando una di queste due soglie viene superata dalla variazione del segnale ricevuto inizia l elaborazione Se la variazione del segnale ricevuto permane tra la soglia di preallarme e la soglia di allarme per circa 40 secondi viene generato un evento di preallarme e si ha la attivazione del rel di allarme Lettura del valore attuale delle soglie di preallarme e ruotare il commutatore SW2 decine fino a che il led rosso 09 sia acceso e ruotare il commutatore SW3 unit fino a che il led rosso D8 sia acceso Il valore letto su questi due commutatori varia da 01 a 80 Il valore di default 15 Modifica del valore attuale delle soglie di preallarme e ruotare i commutatori SW2 decine e SW3 unit sul valore desiderato e premere 53 per confermare l acquisizione e la messa in uso delle nuove soglie Pi basso questo valore magg
51. ers Regenerators and interface multipliers BUS REP see figure below The total number of units Tx and Rx that can be connected to the line are 32 for a higher number of units it is necessary the use of one or more line regenerator RS 485 This is true also for cable lengths of more than 1200 metres Shield connection continuity must be guaranteed to properly protect the line from induced noise The shield must be GROUNDED at only one point i e near the power supply unit The power supply voltage to the RS485 RS 232 interface converter must be delivered by a local power supply unit which must be placed near the converter For the central COM BS connection the serial line coming from the barriers can be used directly without any conversion Installation Handbook page 40 of 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 STAR NETWORK ARCHITECTURE USING BUSREP AS A MULTIPLIER Line RS 485 max 1200 mt SERIAL LINE m CONVERTER Field RS 485 RS 232 BUSREP 1 Devices Line RS 485 Line RS 485 1200 1200 RS232 5 485 i 1 Field Field Devices Devices Field Devices The figure shows a system which requires a RS 485 serial line with several branch loops Star network architecture This architecture is created using a BUSREP as a multiplier The 4 resulting sections can be up to 1 200 mt long each an
52. es ON The values read will be between 01 and 80 default value 60 Decreasing the threshold value will increase the sensitivity of the anti masking evaluation To modify the current value and increase the sensitivity smaller changes produce masking alarm it is necessary to select using the two switches SW3 and SW2 a lower value and then push the button S3 To decrease the sensitivity bigger changes produce masking alarm it is necessary to select using the two switches SW3 and SW2 a higher value and then push the button S3 n Select position 6 on the function switch SW1 The upper pre alarm threshold adjustment phase is activated During phase k the two pre alarm thresholds are set to the same value By increasing the value of the higher pre alarm threshold it is possible to activate the Fuzzy Side Target Discrimination FSTD system This unique system present in MANTA barriers allows it to filter or completely reject signals generated from something moving on either side of the protection beam For example badly fixed fences or bushes The resulting beam has an ellipsoidal shape Installation Handbook page 44 of 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 r To read the current upper pre alarm threshold value proceed as follows e Rotate decimal switch SW2 tens column until the second red led D9 comes ON e Rotate decimal switch SW3 units column until the first red led D8 comes ON The values read will b
53. gistrare gli ultimi 256 avvenimenti occorsi con l indicazione della data dell ora del tipo di evento e di valori ingegneristici qualora ve ne siano per lo specifico evento Questi dati possono essere acquisiti mediante l utilizzo del software MWATEST o WAVE TEST e memorizzati in files storici i quali potranno essere visualizzati e stampati 19 Disponibilit sul ricevitore di un Archivio di 100 registrazioni di 2 5 sec ciascuna del segnale analogico rivelato quando questo supera in valore assoluto un intensit che scelta dall installatore chiamata soglia di monitor rivelato un valore errato 21 Disponibilit Sul ricevitore di un sistema ottico e acustico di allineamento qualifica walk test e settaggio di tutti i parametri 22 Disponibilit sul ricevitore di morsetti per la connessione di un P C su linea seriale RS485 che consente mediante l utilizzo del software MWA TEST o WAVE TEST di parametrizzare collaudare gestire la barriera localmente D n 20 Disponibilit sia sul trasmettitore sia sul ricevitore di un set di parametri dei default che sono messi in uso ogniqualvolta una testa ne sia sprovvista o qualora durante un autodiagnosi sia DI Manuale di Installazione Pagina 25 di 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 APPENDICE A Di seguito sono elencate le impostazioni di alcuni modems per effettuare la connessione remota alle barriere Come si pu notare per
54. he MANTA Antenna HOLE FOR CABLES EXIT Pole for floor 40 mm TS Suggested height from ground 800 mm from 750 to 850mm il POLE ANTIROTATION RADIAL STEEL 300mm ELEMENTS CONCRETE BURIED BASE CONDUIT FOR CABLES ENTRANCE Antenna Antenna 450 mm Ni Wall Pole 40 ___ L 7 HOLE FOR e mm 34 fs WALL WALL 7 di CONDUIT FOR CABLES Installation Handbook page 28 of 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 2 2 Number of Sections When designing a closed perimeter system using volumetric barriers as well as having to split the perimeter into a certain number of sections as required by the end user it must also be remembered that it is always preferable to install an even number of sections This is desirable because any reciprocal interference between adjacent sections is cancelled if two devices of the same type two transmitters or two receivers are installed at the crossover points of the polygon that represents the installation It is evident that this will occur only if the number of sections is even Should it not be possible to have an even number of sections then some careful consideration must be given to interference that might occur in order to find the crossover point that is the best when positioning the transmit
55. i effettuare le operazioni di sincronismo necessario allineare ogni singola barriera avendo cura di disalimentare il trasmettitore Il cavo di connessione tra un trasmettitore e l altro deve essere il pi breve possibile lt 10 metri e deve essere schermato con schermo collegato a terra Per lunghezze del cavo di sincronismo maggiori di 10 metri occorre utilizzare un circuito di ripetizione del sincronismo mod SYNC 01 3 3 3 Connessioni per Stand by Per attivare la funzione di Stand by necessario collegare a GND il morsetto 7 ST BY di MS1 sul Ricevitore o il morsetto 5 ST BY di MS1 sul Trasmettitore N B lo Stand by non inibisce la funzionalit della barriera ma disattiva la registrazione degli eventi nel file storico TX e RX e nel file di monitor del ricevitore 3 3 4 Connessioni per Test La funzione di test viene attivata connettendo il morsetto 6 TEST della morsettiera MS1 del circuito Trasmettitore a GND Se la procedura di test andata a buon fine dopo 10 sec si attiver il rel di allarme sul circuito Ricevitore N B nelle protezioni ad Alto Rischio indispensabile che i rivelatori siano sottoposti con adeguata periodicit al Test operativo In questo modo la centrale di allarme sar in grado di riconoscere i tentativi di elusione Manuale di Installazione Pagina 14 di 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 3 4 Linea Seriale RS 485 3 4 1 Interfaccia Linea Seriale RS 4
56. i movimenti laterali di cui la barriera MANTA dotata Questo sistema di discriminazione rende la barriera MANTA meno sensibile ai segnali provenienti dai bordi laterali del fascio a microonde accentuando la forma ellissoidale del fascio sensibile L attivazione di questo sistema di discriminazione si effettua innalzando il valore della soglia di preallarme superiore rispetto al valore settato nella fase k Lettura del valore attuale della soglia di preallarme superiore e ruotare il commutatore SW2 decine fino a che il led rosso D9 sia acceso e ruotare il commutatore SW3 unit fino a che il led rosso D8 sia acceso Il valore letto su questi due commutatori varia da 01 a 80 Valore di default 15 Modifica del valore attuale delle soglie di preallarme superiore e ruotare commutatori SW2 decine SW3 unit sul valore desiderato e premere 53 per confermare l acquisizione e la messa in uso delle nuove soglie Manuale di Installazione Pagina 20 di 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 o Portando il commutatore di funzione SW1 in posizione 7 possibile leggere e o cambiare il valore della soglia di allarme superiore Come gi visto al punto precedente per la soglia di preallarme superiore per attivare il sistema FSTD anche la soglia di allarme superiore deve essere impostata ad un valore pi alto rispetto a quello settato nella fase Lettura del valore attuale della soglia di allarme superior
57. ion Foti 2 3 Ground connection for MW oscillator DRO Modulation Frequency connection for MW oscillator Ground connection for MW oscillator TRANSMITTER CHANNELS SWITCH N Symbol A Funtin Hexadecimal Modulation Channel Selector DEV 10 Barrier Number selector tens column DEV 1 Barrier Number selector units column TRANSMITTER LEDS N Symbol 6 D6 Faultindication 5 D5 Tamper indication TRANSMITTER JUMPERS N Symbol Function Default 85485 Line termination Jp1 position 1 2 line NOT terminated Closed Enable for FW download Jp2 position 1 2 FW download NOT enabled Closed EA Internal Modulation signal Tx Master Sync Out OUT Jp3 position 2 3 or External Modulation signal 2 3 Tx Slave Sync In Jp3 position 1 2 Closed Installation Handbook page 34 of 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 3 1 2 Receiver Circuit Figure 9 Layout of connectors jumpers LED and presets on receiver board The following tables show the connector pin functions on the MANTA Receiver board RECEIVER TERMINAL BLOCK 51 Term Symbol N N Function Alarm relay contact Normally Closed Alarm relay contact Normally Closed Tamper relay contact Normally Closed bulb contact Tamper relay contact Normally Closed bulb contact Fault relay contact Normally Closed Fault relay contact Normal
58. iore la sensibilit e quindi la larghezza del fascio sensibile Se si desidera aumentare la sensibilit impostare un valore pi basso dell attuale soglia Se si desidera diminuire la sensibilit impostare un valore pi alto I Portando il commutatore di funzione SW1 in posizione 4 possibile leggere e o modificare il valore delle soglie di allarme superiore ed inferiore Le soglie di allarme sono poste una sopra il valore di riposo del segnale ricevuto ed una sotto e sono pi grandi delle corrispondenti soglie di preallarme Esse servono a determinare se alla fine del processo di analisi la variazione del segnale ricevuto di entit sufficiente a determinare l allarme Lettura del valore attuale delle soglie di allarme e ruotare il commutatore SW2 decine fino a che il secondo led rosso D9 sia acceso e ruotare il commutatore SW3 unit fino a che il primo led rosso D8 sia acceso Il valore letto su questi due commutatori varia da 01 a 80 Valore di default 30 Modifica del valore attuale delle soglie di allarme e ruotare commutatori SW2 decine e SW3 unit sul valore desiderato e premere 53 per confermare l acquisizione e la messa in uso delle nuove soglie Manuale di Installazione Pagina 19 di 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 Pi basso questo valore maggiore la sensibilit e quindi la larghezza del fascio sensibile Se si desidera aumentare la sensibilit impostare un valore pi b
59. larme intrusione RX 100mA C NC Contatto manomissione TX RX 100mA C NC Contatto di guasto TX RX 100mA C NC Allarme intrusione RX Led rosso spento A riposo Manomissione TX RX Led rosso spento A riposo Guasto TX RX Led rosso spento A riposo Regolazione delle soglie A bordo SW Peso TX 800 g Peso RX 800 g Dimensioni 205x160mm Profondit comprese le ganasce 200 mm Temperatura di lavoro 25 C 55 Livello di prestazione 3 Grado di protezione dell involucro IP55 Manuale di Installazione Pagina 24 di 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 6 2 Caratteristiche Funzionali 3 Analisi del Valore Assoluto del Segnale ricevuto per garantire un buon rapporto segnale rumore Segnale Basso 4 Analisi del Valore Assoluto del Segnale ricevuto per segnalare guasti deterioramenti mascheramenti 5 Analisi dell andamento del segnale al fine di differenziare per i vari casi il comportamento del Controllo Automatico di Guadagno 7 della temperatura ambiente per rilevare eventuali uscite dal campo di funzionamento ammesso 8 Analisi dell apertura della testa ricevente dellatestatrasmittente 9 Disponibilit di un ingresso di comando di Stand by nel ricevitore e nel trasmettitore per l inibizione delle registrazioni di monitor e di storico lasciando sempre attiva la generazione dello stato di allarme di un ingresso per il comando di Test
60. le Cause Possible Solution Fault Led ON Power too high or too low Check the power supply voltage Temperature too high or too low Check the temperature of the barrier Tx Oscillator Fault Change the Oscillator Tx or Rx failure Change the Electronic board Alarm Led ON Movement or obstacles in the Check that the protected field is free protected field from obstacles and free from objects and or person moving Barrier not properly aligned Re do the alignment procedure as described in points a b c d e f g h i of charter 4 1 2 Wrong channel selection Re do the Channel acknowledge procedure as described in point b j of charter 4 1 2 High AGC Voltage Barrier not properly aligned Re do the alignment procedure as described in points a b c d e f g h i j of charter 4 1 2 obstacles in the protected field Remove obstacles Too low signal transmitted Check the transmitter Rx circuit fault Change the Rx circuit Rx MW part fault Change the RX MW part Tamper Led ON Micro switch open Check the micro switch position Tilt bulb in wrong position Check the position of the tilt bulb Vertical Fault Led ON only on TX circuit BF Oscillator Fault Change the TX circuit MW oscillator Fault Change the MW part 5 2 Maintenance kits The Maintenance Kits comprise circuit boards fitted with microwave cavities and replacement is simple The substitution of circuit and cavity on either transmitter or receiver
61. le della testa trasmittente Tx ed effettuare le operazioni descritte per l orientamento verticale del Ricevitore Al termine delle operazioni bloccare il movimento verticale sia sul Ricevitore sia sul Trasmettitore Manuale di Installazione Pagina 18 di 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 j Portare il commutatore di funzioni SW1 in posizione 2 assicurandosi che durante questa operazione non vi siano ostacoli o alterazioni del campo a microonde ad esempio che gli stessi operatori non entrino nel campo Questo fatto riveste una notevole importanza in quanto in questa fase la barriera acquisisce sia il valore del canale di modulazione sia il valore di campo presenti un alterazione del campo in questo momento condurrebbe quindi ad un acquisizione scorretta L acquisizione di questi parametri da parte del ricevitore avviene dopo alcuni secondi che stato premuto il pulsante S3 L accensione contemporanea dei 2 leds rossi D8 e D9 indica che l acquisizione del canale del valore di segnale e la misura della qualit dell allineamento sono iniziate dopo qualche secondo se il canale ed il valore del segnale sono stati acquisiti correttamente i 2 leds si spengono ed il buzzer si attiva emettendo un numero di suoni BEEP inversamente proporzionale alla qualit dell allineamento secondo la seguente tabella 1 Beep Qualit Ottima 2beep Qualita Buona 3 Beep Qualita Scarsa 4Beep Qualita Insufficiente 5 o piu Be
62. lla capacit di protezione della barriera Questo genere di alterazioni possono essere provocate per esempio dal progressivo accumularsi di uno strato di neve lungo la tratta oppure potrebbero essere prodotte dolosamente per cercare di superare la protezione Lettura del valore attuale delle soglie di mascheramento e ruotare il commutatore SW2 decine fino a che il secondo led rosso D9 sia acceso e ruotare il commutatore SW3 unit fino a che il primo led rosso D8 sia acceso Il valore letto su questi due commutatori varia da 01 a 80 Valore di default 60 Modifica del valore attuale delle soglie di mascheramento e ruotare commutatori SW2 decine SW3 unit sul valore desiderato e premere 53 per confermare l acquisizione e la messa in uso delle nuove soglie Pi basso questo valore maggiore la sensibilit Se si desidera aumentare la sensibilit impostare un valore pi basso dell attuale soglia Se si desidera diminuire la sensibilit impostare un valore pi alto Portando il commutatore di funzione SW1 in posizione 6 possibile leggere e o modificare il valore della soglia di preallarme superiore Qualora ci siano disturbi laterali continui provocati ad esempio da una recinzione metallica non ben fissata e che muovendosi tocca il fascio vegetazione che muovendosi interferisce ai lati del fascio possibile attivare il sistema software FSTD Fuzzy Side Target Discrimination discriminazione Fuzzy de
63. lue processing to guarantee the optimum S N value Low level signal 6 Analysis DC Power supply voltage processing High or Low 9 Availability Stand by input control to inhibit monitor and historical memories Alarm status generation always active Availability Test input control to produce on receiver the alarm relay activation in case of positive result 11 Activation Three static relay output for alarm tamper fault on receiver and two for tamper and fault on transmitter Three signalling LED for alarm tamper fault on receiver and two for tamper and fault on transmitter 15 Availability 16 positions switch for modulation channel frequency choice During the installation phase the receiver identifies and stores automatically which channel must be used during working phase power supply completely OFF analogue events monitoring and historical events record 18 Availability Historical event records on transmitter and receiver for the last 256 events with the value if any data time and event types indication The data acquisition can be done with MWA TEST or WAVE TEST software the data will be stored in historical files for read and print analogue signal if higher then user preset value called monitor threshold self diagnosis detects a wrong parameter setting operations 22 Availability P C connector on transmitter and receiver for serial line RS485 connection used with software MWA
64. ly Closed 7 ST BY Auxiliary input for Stand By command Norm Open from GND TEST Auxiliary input for Test command Norm Open from GND Ground auxiliary connection RECEIVER TERMINAL BLOCK MS2 Symbol Funcdin Installation Handbook page 35 of 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 RECEIVER CONNECTOR J1 10 pin Connector for local PC Serial Line connection Mwatest or WAVE TEST SW 1 2 4 Not Connected Power Supply 13 8 V Converter interface RS 485 232 Low Line for RS 485 L High Line for RS 485 Ground RECEIVER CONNECTOR J2 Connector for MW detector Ground connection for MW detector p 2 DET Connection for MW detector LOS Ground connection for MW detector RECEIVER CONNECTOR J7 Connector for External Buzzer Command for external buzzer EUN 2 4138 Power Supply voltage for external buzzer 413 8 V _ 3 Power Supply voltage for external buzzer 13 8 V RECEIVER LEDS RS485 Line termination Jp1 position 1 2 line NOT 1 2 terminated Closed Enable for FW download Jp2 position 2 3 FW 2 3 download NOT enabled Closed Installation Handbook page 36 of 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 SET UP BUTTON FOR ALIGNEMENT AND SETTING Button to accept data in alignment operation and to write parameter in setting operations RECEIVER FUNCTION SWITCH SW1 N Symol Funtin
65. new level signal simply by a momentary interruption of the beam for example by passing a hand through the beam in front of the TX head instead pushing S3 button g Once the best alignment is achieved maximum signal available secure the bracket screws both on transmitter and receiver to lock the horizontal movement h Unlock the vertical movement of the receiver and move it slightly upward Push S3 button and then move the head downward looking for the maximum signal as indicated in the previous point e i Unlock the vertical movement of the transmitter and repeat the operation described for the receiver vertical alignment Once the best vertical alignment is achieved maximum signal available lock the vertical movement both on transmitter and receiver j Turn the function switch SW1 to position 2 making sure that during this operation nothing is within the microwave beam For example ensure that people do not walk between the transmitter and the receiver Remember that this operation is very important because it is now that the barrier acquires the modulation channel value and the level of the microwave signal A disturbance in the microwave beam at this moment will make the installation incorrect and therefore it will not be secure When button S3 is pressed the 2 leds D8 and D9 will illuminate together The acquisition ends a few seconds after the S3button is pressed If the channel and the signal acquired are correct the 2 leds
66. ogni tipo di modem ci sono 2 impostazioni diverse che corrispondono al CENTRO Terminale Operatore che effettua la connessione Remota alle barriere MANTA e all IMPIANTO la rete RS 485 di interconnessione delle Barriere MANTA Digicom Botticelli 56K V 90 Digicom Leonardo56 Centro at amp f Carica parametri di default atx3 Rilevazione tono di occupato at c3 Compressione MNP5 amp V 42 bis at e0 Autoretrain disabilitato at ms 9 1 9600 9600 at n3 Effettua la connessione solo a 9600 bps Correzione d errore V 42 LAPM MNP ate0 Disabilita echo dei comandi at amp w Memorizza parametri Impianto at amp f Carica parametri di default atx3 Rilevazione tono di occupato at c3 Compressione MNP5 amp V 42 bis at e0 Autoretrain disabilitato at ms 9 1 9600 9600 at n3 Effettua la connessione solo a 9600 bps Correzione d errore V 42 LAPM MNP ate0 Disabilita echo dei comandi ats0 1 Risposta automatica dopo uno squillo at amp w Memorizza parametri VACF1433VQE Centro at amp f Carica parametri di default atx3 rilevazione tono di occupato 0 Tolta compressione MNP5 amp V 42 bis at e0 Autoretrain disabilitato at n5 Correzione d errore MNP ate0 Disabilita echo dei comandi at amp w Memorizza parametri Impianto at amp f Carica parametri di default atx3 rilevazione tono di occupato at cO Tolta compressione MNP5 amp V 42 bis at e0 Autoretrain disabilitato at n5 Correzione d erro
67. re MNP ats0 1 Risposta automatica dopo uno squillo ate0 Disabilita echo dei comandi at amp w Memorizza parametri Manuale di Installazione Pagina 26 di 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 56K Modem Centro at amp f Carica parametri di default atx3 rilevazione tono di occupato at c3 Compressione MNP5 amp V 42 bis at e0 Autoretrain disabilitato at ms 9 1 9600 9600 Effettua la connessione solo a 9600 bps at n3 Correzione d errore V 42 LAPM MNP ate0 Disabilita echo dei comandi at amp w Memorizza parametri Impianto at amp f Carica parametri di default atx3 rilevazione tono di occupato at c3 Compressione MNP5 amp V 42 bis at e0 Autoretrain disabilitato at ms 9 1 9600 9600 Effettua la connessione solo a 9600 bps at n3 Correzione d errore V 42 LAPM MNP ats0 1 Risposta automatica dopo uno squillo ate0 Disabilita echo dei comandi at amp w Memorizza parametri Trust comunicator 56K ESP Centro at amp f Carica parametri di default atx3 rilevazione tono di occupato at c3 Compressione MNP5 amp V 42 bis at e0 Autoretrain disabilitato at n3 Correzione d errore V 42 LAPM MNP ate0 Disabilita echo dei comandi at amp w Memorizza parametri Impianto at amp f Carica parametri di default atx3 rilevazione tono di occupato at c3 Compressione MNP5 amp V 42 bis at e0 Autoretrain disabilitato at n3 Correzione d errore V 42 LAPM MNP ats0 1 Risposta automatica dopo uno sq
68. riera dovesse essere disalimentata o resettata prima di aver effettuato l operazione descritta la punto tutti i settaggi effettuati verranno persi Manuale di Installazione Pagina 21 di 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 4 2 Allineamento e Verifica con Software Per visualizzare e gestire con estrema precisione tutti i parametri software della barriera compresi i livelli analogici delle soglie e del segnale ricevuto possibile utilizzare un PC con il programma MWATEST o WAVE TEST CIAS riferirsi alla documentazione tecnica di questi programmi per le procedure di collegamento e o gestione delle funzionalit software Connessione Stop Tempo Totale Schermo Tempo Trascor Impianto Centrale Nucleare Svedese Dispositivo 1 Manta RX MAR2 01 09 07 mR Server Disconnesso COM 3 03 10 2007 12 04 36 5367 mV Manuale di Installazione Pagina 22 di 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 5 MANUTENZIONE E ASSISTENZA 5 1 Ricerca Guasti In caso di falsi allarmi verificare i parametri riscontrati durante Installazione che saranno stati registrati nell apposita Scheda di Collaudo allegata e se si riscontrano delle variazioni che eccedono i limiti indicati rivedere i relativi punti nel capitolo Allineamento e Verifica 4 Difetto Possibile Causa Possibile Soluzione Led Guasto acceso Tensione alta e o bassa Verificare la tensione di alimentazione Tempera
69. sary to select using the two switches SW3 and SW2 a higher value and then push the button S3 Installation Handbook page 43 of 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 l Select position 4 on the function switch SW1 The alarm thresholds adjustment phase and the walk test phase are activated The two alarm thresholds are set above and below the quiescent field value They are higher than the corresponding pre alarm thresholds and are used to evaluate at the end of the analysis process if the field value change is enough to generate an alarm event To read the current alarm threshold values proceed as follows Rotate decimal switch SW2 tens column until the second red led 09 comes Rotate decimal switch SW3 units column until the first red led D8 comes ON The values read will be between 01 and 80 default value 30 Decreasing the threshold value increases the sensitivity and the beam dimensions To modify the current value and increase the sensitivity it is necessary to select using the two switches SW3 and SW2 a lower value and then push the button S3 To decrease the sensitivity it is necessary to select using the two switches SW3 and SW2 a higher value and then push the button S3 During this phase SW1 position 4 it is also possible to perform the walk test The barrier works using the current thresholds and any change in received MW field strength for example due to an intruder moving in the s
70. sono meno di 32 ma possono essere dislocati su una linea lunga 3600 mt BUSREP 2 Linea RS 485 Linea RS 485 max 1200 mt max 1200 mt 21H L1 gt Da Py ole Barriere Barriere Barriere 3 5 Collegamento da Accesso Hemoto Per interfacciare il modem per linea telefonica commutata con velocit di 9600 b s alle barriere MANTA oltre alla conversione RS485 RS232 occorre la conversione cross mostrata di seguito 485 232 MODEM DB25 M DB25 M Manuale di Installazione Pagina 16 di 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 4 ALLINEAMENTO E VERIFICA 4 1 Allineamento e Verifica Le barriere MANTA sono dotate di un sistema di allineamento elettronico di un sistema di regolazione dei parametri di lavoro e di un sistema di test che rendono particolarmente semplici ed efficaci sia le operazioni di installazione che di manutenzione periodica senza la necessit di utilizzare particolari strumenti 4 1 1 Operazioni sul Trasmettitore e Pertogliere il radome coperchio frontale svitare le 3 viti fintanto che esse non girano a vuoto Allontanare il radome dal fondo questa operazione provochera l apertura del microinterruttore Tamper presente sul PCB e Connettere i fili di alimentazione continua 13 8 V ai morsetti 1 e 2 di MS2 Fig 8 e Predisporre uno dei 16 canali di modulazione disponibili ruotando il commutatore esadecimale SW1 in una posizion
71. t mod SYNC 01 3 3 3 Stand by connection For activation of the Stand by function it is necessary connect terminal 7 ST BY of MS1 terminal block on the receiver to ground and connect terminal 5 ST BY of MS1 terminal block on the transmitter to ground Remark the Stand by operation does not inhibit the barrier operation but deactivates the recording of events into the historical file TX and RX and into the monitor file RX 3 3 4 Test connection The Test function is activated by connecting terminal 6 TEST of terminal block MS1 on Transmitter to ground If the test procedure is successful the alarm relays on Receiver circuit will be activated 10 seconds later Remark for high risk protection it is necessary to conduct a Periodic Test of the equipment During these tests the control panel will be able to detect tamper activity Installation Handbook page 39 of 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 3 4 Serial Line RS 485 3 4 1 RS 485 232 Network Connection Interface A standard RS 485 serial interface is provided on both transmitter and receiver of the MANTA barrier The communication parameters are the following Mode Asynchronous Half Duplex Baud rate 9600 b s Character length 8bit Parity control No Parity Stop bit 1 3 4 2 RS 485 Serial Line connections The cable interconnections should be multi drop type BUS and the branches for connection of the units as short as possi
72. tente torna al basso per l avvenuto recupero del segnale procedere nuovamente ad orientare la testa Qualora durante l orientamento anzich aumentare la frequenza del suono intermittente diminuisce significa che il segnale ricevuto dopo il movimento della testa diminuito e occorre quindi ruotare nella direzione opposta la testa e ricercare un eventuale nuovo massimo indicato dall aumento della frequenza dell intermittenza del suono Se non si trovano altre posizioni migliori significa che l orientamento attuale fornisce il massimo del segnale f Allentare le viti di fissaggio al palo per effettuare l orientamento sul piano orizzontale della testa trasmittente e ripetere le operazioni descritte al punto e Anzich utilizzare il pulsante S3 per l operazione di acquisizione del nuovo livello di segnale ricevuto possibile oscurare momentaneamente il fascio a MW per esempio passando una mano davanti alla testa Grazie a questa prestazione possibile comandare l acquisizione del nuovo segnale senza recarsi presso il ricevitore per premere il pulsante S3 g Ottenuto il miglior puntamento quindi il massimo segnale disponibile bloccare il movimento orizzontale sia sul Ricevitore sia sul Trasmettitore h Sbloccare il movimento verticale della testa ricevente Rx ed orientarla verso l alto Ruotare lentamente verso il basso ricercando il massimo segnale come descritto precedentemente al punto e i Sbloccare il movimento vertica
73. ter near the receiver The following pictures show some typical cases for which the best solution is given see figure 1 CORRECT CORRECT CORRECT Figure 1 Installation Handbook page 29 of 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 2 3 Ground conditions It is not recommended to install the equipment along sections with tall grass more than 10 cm ponds longitudinal waterways and all those types of ground whose structure is subject to rapid changes 2 4 Presence of Obstacles Fences are generally metallic and therefore highly reflecting This causes various problems and for this reason some precautions are suggested first of all make sure that the fence has been properly fixed so that it does not move in the wind if itis possible the microwave beam should not be placed exactly in parallel to a metallic fence but at a slight angle to it metal fences placed behind the equipment night cause distortions to the sensitive beam and might cause movement detection in unexpected areas with subsequent generation of false alarms likely when the Mw barrier must be installed in a corridor between two metallic fences the width of the corridor should be not less
74. to 5 m if less contact CIAS technical assistance Along the section within the area of the protection field pipes poles or similar e g lamp posts are allowed as long as their dimensions with respect to the protection beam are not too excessive Trees hedges bushes in general need very great care if near or within the protection beams These obstacles vary in size and position they grow and they can be moved by the wind Therefore it is not recommended that these obstacles are allowed within the protected sections Figure 2 It is possible to tolerate the presence of these elements near the protected sections only if their growth is limited by routine maintenance and if their movement is stopped using containment barriers Various Obstacles might be present along the protected sections For them it is necessary to consider their positions and take the same necessary precautions adopted for the above cases These can cause Dead zones with no protection and Hyper sensitive zones which can cause false alarms Installation Handbook page 30 of 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 2 5 Dimensions of the Sensitive Beam The amplitude of the Sensitive Beam depends on the distance between the transmitter and the receiver and on the sensitivity setting The figures below show the horizontal dimension at half range of the sensitive beam with maximum and minimum sensitivity see following figures
75. tore locale collocato in pratica vicino al convertitore stesso e quindi al PC Manuale di Installazione Pagina 15 di 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 ARCHITETTURA DI LINEA STELLARE IMPIEGANDO BUSREP COME MOLTIPLICATORE Linea RS 485 max 1200 mt CONVERTITORE Barriere on Ae Linea RS 485 1 Linea RS 485 max 1200 mt max 1200 mt 1 32 1 1 Dispositivi Barriere di Campo Barriere Nella figura rappresentato un impianto che richiede una linea seriale RS 485 a pi rami Architettura Stellare Questa architettura realizzabile utilizzando un BUSREP come moltiplicatore Le 4 tratte risultanti possono essere lunghe ciascuna fino a 1200 mt e ad ognuna possono essere collegati un numero massimo di dispositivi pari a 32 compreso il BUSREP e nella prima tratta compreso il convertitore di linea seriale CONVERTITORE DI LINEA SERIALE RS 485 RS 232 ESTENSIONE DELLA DISTANZA IMPIEGANDO BUSREP COME RIGENERATORE Ej RS232 RS 485 13 8 Vcc AUMENTATORE LOCALE 0 Vcc Nella figura rappresentato un impianto che richiede una linea seriale RS 485 di lunghezza superiore a 1200 mt Essa stata spezzata utilizzando due BUSREP come rigeneratori in 3 tratte ciascuna di lunghezza inferiore In questo caso i dispositivi di campo
76. tura alta e o bassa Verificare la temperatura della barriera Guasto oscillatore Tx Sostituire l oscillatore Tx o Rx guasti Sostituire il circuito Led Allarme acceso Movimento od ostacoli nel Assicurarsi che il campo protetto sia campo protetto libero da ostacoli e non vi siano oggetti e o persone in movimento Teste disallineate Rifare il puntamento come descritto nel capitolo 4 1 2 punti_a b c d e f g h i Selezione canale errata Effettuare nuovamente l acquisizione del canale capitolo 4 1 2 punti b j VRag elevato Teste disallineate Eseguire il puntamento come descritto nel capitolo 4 1 2 punti a b c d e f g h i j Ostacoli nel campo protetto Rimuovere gli ostacoli Segnale trasmesso insufficiente Controllare il Trasmettitore Circuito guasto Sostituire il Ricevitore Ricevitore a microonde guasto Sostituire il Rilevatore a microonde Led Manomissione acceso Microinterruttore aperto Verificare chiusura microinterruttore Ampolla in posizione errata Verificare la posizione dell ampolla Led Guasto acceso solo circuito Tx Guasto oscillatore BF Sostituire circuito Guasto oscillatore MW Sostituire Cavit MW 5 2 Kit Assistenza Kit di Assistenza sono costituiti dalla parte di elaborazione circuitale completi di parte a microonde L operazione di sostituzione molto semplice Un dato importante da tenere presente che il kit d assistenza sempre tarato per la massima prestazione cio 80
77. uillo ate0 Disabilita echo dei comandi at amp w Memorizza parametri MODEM CIAS 9600 Impianto at amp f Carica parametri di default ats0 1 Risposta automatica dopo uno squillo 0 Nessuna compressione MNP5 amp V 42 bis at e0 Autoretrain disabilitato at n5 Correzione d errore MNP ate0 Disabilita echo dei comandi at amp w Memorizza parametri Il modem CIAS 485 9600 non necessita ne della conversione RS 485 232 ne del cavo cross essendo predisposto per accettare direttamente la connessione alla linea seriale RS485 Manuale di Installazione Pagina 27 di 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 1 DESCRIPTION 1 1 Description The MANTA is a digital microwave barrier from CIAS for internal and external volumetric protection The system can detect the presence of somebody or something moving within the sensitive field created between a transmitter Tx and a receiver Rx The received signal is processed digitally and analysed with Fuzzy logic in order to obtain the maximum performance and a minimum false alarm rate The MANTA is available with the following field ranges MANTA 50 Range 50 metres MANTA 80 Range 80 metres 2 INSTALLATION 2 1 Preliminary Information By unscrewing the articulated joint with the cable access hole and rotating it to the top position it is possible to install the MANTA barrier on a wall The following pictures the different installation methods for t
78. ult setting corresponds to a medium sensitivity suitable for most situations Installation Handbook page 31 of 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 2 6 Length of the Dead Zones near the equipment The length of the Dead Zones near the equipment is based on the distance of the equipment from ground on the sensitivity set on the receiver and on the type of antenna used With regard to the considerations stated above and based on site requirements the equipment must be installed at a certain height from ground In a typical site the height should be 85 cm from the ground and the centre of the antenna With medium sensitivity setting the suggested crossing overlap is 3 5 m 100 p here zz 00 Antenna Maximum Minimum 90 centre height sensitivity sensitivity 9 from ground cm 80 70 70 60 60 50 50 40 40 30 30 20 20 10 Dead Zone lenght m 1 2 3 4 5 6 7 8 9 10 Figure 5 MANTA 50 80 Dead zone length near the equipment versus installation height E Figure 6 MANTA 50 80 Dead zone length near the equipment versus installation height 80 85 cm Figure 7 Overlapping of two beams in a cross Installation Handbook page 32 of 51 MANTA 50 80 CIAS Elettronica S r l Ed 1 2 3 1 Terminal Blocks Connectors and Circuit Functions 3 1