1. SUPPLY VOLTAGE MEASURED BETWEEN PINS 4 60FJ1 PIN4 GND TENSIONE DI ALIMENTAZIONE INTERNA MISURATA TRA IL PIN 16 DI J1 E GND INSIDE SUPPLY VOLTAGE MEASURED BETWEEN PIN 16 OF J1 AND GND TENSIONE OSCILLATORE FUNZIONANTE MISURATA TRA IL PIN 13 DI J1 E GND OSCILLATOR OK VOLTAGE MEASURED BETWEEN PIN 13 OF J1 AND GND O MASTER O MASTER SELEZIONE MASTER SLAVE SOLO VERSIONE e SLAVE SLAVE MASTER SLAVE SELECTION ONLY S VERSION CANALE DI MODULAZIONE SELEZIONATO MODULATION CHANNEL SELECTED misura puo essere effettuata anche con lo strumento STC 95 Itis possible to make the measure also by the STC 95 OSSERVAZIONI DELL INSTALLATORE INSTALLER COMMENTS Data installazione Installation date Firma installatore Installer signature LU I H D O C LU lt lt SCHEDA DI COLLAUDO TEST SHEET CIAS ERMUSA RX NUMERO DI SERIE SERIAL NUMBER Cliente Customer Indirizzo Address Barriera Barrier N VALORI MISURATI SUL RICEVITORE MEASURED VALUES ON THE RECEIVER VALORI MISURATI MISURE VALORI TIPICI MEASURED VALUES MEASUREMENTS INSTALLAZIONE MANUTENZIONE INSTALLATION MAINTENANCE VALUES gt 2 E TENSIONE DI ALIMENTAZIONE MISURATA TRA I PIN 4 6 DI J1 PIN 4 GND SUPPLY VOLTAGE MEASURED BETWEEN PINS 13 8 VDC 10 4 60F J1 PIN 4 GND TENSIONE DI ALIMENTAZIONE INTERNA MISURATA TRA IL PIN 12 DI J1
2. CIAS ERMUSA Barriera a Microonde per protezioni esterne Manuale di Installazione External Microwave Protection Barrier Installation Handbook Edizione Edition 2 0 CIAS Elettronica S r l Ed 2 0 INDICE T DESCRIZIONE cele 3 Descrizione a aaa alcalina 3 2 INSTALLAZIONE a i cpm mmm cla 4 2 1 Informazioni prelimmari GIR na 4 2 ll uUMedidbdnstallaziOolle 25 52 22252255 8 9 2 0 aaa A ATI rr 4 2 2 Numero dilata laine 5 2 CondmionLdel Terreno speci rara ai 6 24 Presenza droOstacol T TROPAS 6 2 5 Ampiezza CEE ASCH 7 2 6 Lunghezza delle Zone Morte in prossimit degli apparati eee eese ee 2 2 2222200000 8 3 COLLEGAMENTI s sr svrr esserne siena nnnm 9 3 1 Morsettiere connettori e funzionalit del circuito eee eee eee eese e eese esset eeeess 9229 9 922999 9229996 0 3 1 1 EN aaa 0 POMMES RICEVO 1 3 2 Collegamento all Alimentazione Principale iaia nia iii iran 13 3 2 0 Collesamento allAliumentazione x deco secet tede deserens begehrt delebo e bo eret etes bte et uetus 13 39 Collegsamento alla ej co 13 3 3 1 Contat
3. Manuale di Installazione pagina 12 di 44 ERMUSA CIAS Elettronica S r l Ed 2 0 3 2 Collegamento all Alimentazione Principale 3 2 1 Collegamento all Alimentazione Le teste devono essere alimentate in corrente continua alla tensione nominale di 13 8 V Il collegamento tra l alimentatore e la testa deve essere adeguatamente dimensionato quindi la sezione del conduttore deve essere calcolata in base alla lunghezza del collegamento ed all assorbimento degli apparati Nel caso in cui i collegamenti risultassero troppo lunghi si consiglia l utilizzo dell alimentatore supplementare Connettere i fili di alimentazione continua 13 8 V e GND rispettivamente ai morsetti 1 e 2 della morsettiera MS1 sia del circuito Tx che del circuito Rx Il cavo che porta l alimentazione all apparecchiatura deve essere schermato 3 3 Collegamento alla Centrale Le connessioni alla Centrale di elaborazione devono essere effettuate mediante cavi schermati Le Uscite degli apparati sono costituite da contatti normalmente chiusi liberi da potenziale per la segnalazione dei seguenti stati Allarme Manomissione Guasto sono inoltre presenti solo per la versione S ingressi per attivare le seguenti funzioni Sincronismo Tx Stand By Tx Test Tx 3 3 1 Contatti d allarme Allarme Guasto Manomissione contatti di uscita per Allarme e Guasto sono costituiti da Rel statici con portata 100 mA max e presentano ai morsetti una resistenza complessiva
4. massima e minima figure 7 e 8 20 SS Larghezza zona SE Sensibilit 16 a met tratta m Massima 14 12 10 8 6 Sensibilit 4 minima 2 Lunghezza della tratta m 10 20 30 40 50 60 70 80 90 100 Figura 7 Larghezza della zona sensibile a met tratta in funzione della lunghezza in spazio libero 20 Altezza zona ie ee Altezza zona ee 18 sensibile Sensibilit 16 8 met tratta m Massima 14 12 10 8 6 Sensibilit 4 minima sati on 2 Lunghezza della tratta m 10 20 30 40 50 60 70 80 90 100 Figura 8 Altezza della zona sensibile a met tratta in funzione della lunghezza in spazio libero Nota E necessario ricordare che per l apparato ERMUSA la regolazione di Sensibilit deve essere presa in considerazione per ricavare la dimensione dei fasci sensibili a met della tratta Quanto pi alta la soglia tanto pi bassa e la sensibilit e viceversa Manuale di Installazione pagina 7 di 44 ERMUSA CIAS Elettronica S r l Ed 2 0 2 6 Lunghezza delle Zone Morte in prossimit degli apparati La lunghezza delle Zone Morte in prossimit degli apparati in funzione sia della distanza del
5. same as channel preset on Transmitter unit Connect the STC 95 instrument to the ERMUSA RX barrier as shown in Fig 12 Insert the seven pins connector into the connector J1 present on Receiver circuit fig 10 a Check that LED Rx Tx 1 22 is lights up If not press the key 1 21 for lights up b Press the key 0 10 a number of time as needed for lights up the LED 13 8 V 4 The voltage indicated by display 2 must be 13 8 V 10 Go on the rear part of receiver head and verifies that the path is free from moving obstacles If the previous visual system alignment is correct check that the LED D1 channel identification are lights up Fig 11 For the path optimisation go on with electronic alignment see next c Check that the LED On 16 is off If not press the key buzzer 15 for turn the LED off this force the STC 95 internal buzzer not active d Check that the LED open 18 is light up if not press the key loop 17 for the loop opening and turn on the LED e Press the key 10 until the LED Field Rx 5 lights up Check that a 6 V 10 96 voltage is read on the display and that the mid LED is glowing on the LED 3 Should the voltage value differ and should the glowing LED be the end ones then press either key fl gain 11 or key gain 12 till the previously described condition arises i e the LED in the middle of the bar lights up and a 6 V 10 v
6. 13 8 V 2 GND Ingresso negativo della tensione di alimentazione 0 V 3 ALLO Contatto Rel di Allarme C Z O Z SS 4 ALL Contatto di Rel di Allarme NC O Z o O o 5 PTO Contatto di Manomissione C Ampolla 6 Contatto di Manomissione NC Ampolla CONNETTORE Connettore per lo strumento STC 95 Pin Simblo FUNZIOE 4 GND Tensione di alimentazione 0 V 6 Vcc Tensione di alimentazione 13 8 V 8 Soglia Soglia di allarme 300 mV 9 V 9 200mV Segnalerivelato 200mVpp 0 O 10 Rivelata Tensione rivelata normalizzata a 0 V con circuito a riposo 13 Aleme Segnale di barriera in Alame 14 VRag Uscita tensione Regolatore Automatico di Guadagno Manuale di Installazione pagina 11 di 44 ERMUSA CIAS Elettronica S r l Ed 2 0 LEDS Indica il riconoscimento del canale Tx Verde normalmente On D6 Indica Allarme Rosso normalmente Off D 10 Indica se il dispositivo alimentato Verde normalmente On JUMPERS Simoo 3 X FUNZIONE Abilitare disabilita i leds Chiuso 2 Leds Abilitati TRIMMERS Regolazione della Sensibilit minima in senso antiorario Regolazione dell Integrazione minima in senso antiorario SWITCHES Simbolo A FUNZIONE Selettore canali 1 4
7. Rx letto sul display 2 si porti a 6 V 10 e si illumini il led centrale della barra N B La precisione del valore assoluto 6 V di questa lettura non molto importante essa infatti non dipende dal valore assoluto del segnale a MW ricevuto ma bensi dalla taratura dello strumento di misura STC 95 La stabilit invece di questa lettura direttamente collegata alla Stabilit del segnale MW ricevuto pertanto una lettura instabile sta ad indicare che il segnale ricevuto perturbato occorre quindi accertare che non vi siano nel campo di protezione oggetti in movimento o che il segnale ricevuto sia insufficiente e quindi affetto da rumore In caso di dubbio verificare la reale situazione utilizzando un oscilloscopio collegato al connettore RCA dell STC 95 vedi punto S 1 Premere il tasto 10 fino ad ottenere l accensione del led Vrag Rx 7 e verificare sul display che la tensione letta sia compresa tra 2 5 6 5 V Questo valore di RAG direttamente proporzionale alla distanza tra testa trasmittente e ricevente Manuale di Installazione pagina 17 di 44 ERMUSA CIAS Elettronica S r l Ed 2 0 m Premere il tasto 10 fino ad ottenere l accensione del led sens RxTx 6 Agire sul trimmer PT1 testa ricevente fig 10 fino a leggere sul display un valore compreso tra 0 3 9 V 10 9 Va tenuto presente che il valore di 0 3 V corrisponde alla massima sensibilit e il valore 9 V corris
8. connessioni alla Centrale FUNZIONE amp ORI ione C Contatto di Manomissione NC Ampolla SYNC Uscita ingresso segnale di Sincronismo Versione S SIBY Ingresso funzione Standby dell apparato Versione TEST Ingresso funzione di Test dell apparato Versione S 32 A 5 PTO ContattodiManomissione C Ampola 8 NG Manuale di Installazione pagina 9 di 44 ERMUSA CIAS Elettronica S r l Ed 2 0 CONNETTORE Connettore per lo strumento STC 95 Tensione di alimentazione 0 V 4 6 138V Tensione di alimentazione 13 8 V 1 16 OSCILL Segnale funzionamento Oscillatore 4 5 V Alimentazione interna 9 V LEDS Indica presenza alimentazione Verde normalmente On Indica Guasto del dispositivo Rosso normalmente Off Indica la funzione di Test attivata Rosso normalmente Off JUMPERS Simbolo JP 5 Abilita disabilita i Leds Chiuso Leds Abilitati SWITCHES Simbolo FUNJONE Selettore canali 1 4 Manuale di Installazione pagina 10 di 44 ERMUSA CIAS Elettronica S r l Ed 2 0 3 1 2 Circuito Ricevitore Figura 11 Nelle seguenti tabelle sono indicate le funzioni delle morsettiere connettori selettori e trimmer presenti sulla scheda ERMUSA TX 77 d principale per le connessioni alla Centrale i FINZIONE 1 13 8V Ingressotensionedialimentazione
9. di 35 Ohm L uscita di Manomissione data dal contatto del Microinterruttore e dal contatto dell Ampolla antisposizionamento con portata 100 mA max Le uscite sono attivate per i seguenti motivi Uscita di Allarme Allarme intrusione sul Ricevitore Allarme canale sul Ricevitore Uscita di Manomissione Apertura della testa a microonde Tx o Rx Sposizionamento apertura ampolla Tx o Rx Uscita di Guasto solo per le versioni S Guasto oscillatore a BF Tx Guasto oscillatore a RF Tx Manuale di Installazione pagina 13 di 44 ERMUSA CIAS Elettronica S r l Ed 2 0 3 3 2 Connessione per Sincronismo SYNC presente solo nella versione S viene utilizzato quando si desidera sincronizzare tra loro due dispositivi Tx relativamente vicini tra loro in modo che possano funzionare alla stessa frequenza di modulazione Per effettuare il sincronismo occorre connettere tra loro i morsetti 7 SYNC e 2 GND della morsettiera MS1 dei due trasmettitori E inoltre necessario selezionare un trasmettitore come Master e l altro come Slave mediante il ponticello E E Chiuso selezionato il sincronismo interno quindi il Tx Master E Aperto selezionato il sincronismo esterno quindi il Tx Slave N B Prima di effettuare le operazioni di sincronismo necessario allineare ogni singola barriera avendo cura di disalimentare il trasmettitore Il cavo di connessione tra un trasmettitore
10. il collaudo del trasmettitore ERMUSA occorre procedere nel seguente modo togliere la calotta di plastica svitando le apposite viti verificare la connessione dei fili di alimentazione alla morsettiera MS1 figura 10 verificare l accensione del led D10 con alimentazione presente predisporre agendo sul selettore SW1 una delle 4 frequenze disponibili Effettuare la interconnessione tra lo strumento STC 95 e la barriera ERMUSA TX inserendo l apposito cavetto flat a 16 poli nel connettore J1 a Verificare che il led Rx Tx 1 22 sia acceso Qualora fosse spento premere il tasto 4 21 per accenderlo b Premere il tasto 10 tante volte quante ne servono per accendere il led 13 8 V 4 La tensione letta sul display 2 dovr essere 13 8 V 10 96 c Premere il tasto 10 fino alla accensione del led 9V Tx 8 La tensione letta sul display 2 dovr essere 9 V 10 96 d Premere il tasto 10 fino alla accensione del led sens Rx Tx 6 La tensione letta sul display 2 dovr essere 4 5 V 10 96 4 1 2 Operazioni sul Ricevitore Per effettuare la taratura e il collaudo del Ricevitore ERMUSA occorre procedere nel seguente modo togliere la calotta plastica svitando le apposite viti connettere fili di alimentazione ai morsetti 1 e 2 della morsettiera MS1 figura 11 verificare che si accenda il led D10 con alimentazione presente predisporre agendo s
11. il tasto j 10 fino ad ottenere l accensione del led field Rx 5 Verificare che sul display sia leggibile una tensione di circa 6 V 10 96 e sulla barra a led 3 sia acceso il led centrale Qualora il valore di tensione fosse diverso e il led illuminato fosse verso i limiti estremi premere il tasto gain fl 11 o il tasto gain U 12 fino a quando si verificher la condizione precedentemente descritta accensione led centrale della barra e indicazione di 6 V 10 sul display L f Dopo aver allentato le viti di fissaggio sul palo ruotare il ricevitore sul piano orizzontale fino ad ottenere la massima lettura sul display 2 Ripetere l operazione di puntamento agendo sulla regolazione orizzontale della testa trasmittente h Ottenuto il migliore puntamento bloccare il movimento orizzontale sulle due teste TX e RX I Sbloccare il movimento verticale della testa ricevente e orientarla verso l alto Spostarla lentamente verso il basso fino ad ottenere la massima lettura sul display 2 e sulla barra a led 3 con le stesse modalit adottate per la regolazione orizzontale j Ripetere il movimento verticale sulla testa TX e ottenuta la massima lettura bloccare movimento verticale sulle due teste TX e RX Premere il pulsante loop 17 e verificare lo spegnimento del led open 18 Verificare che dopo un tempo di recupero massimo di due minuti primi il valore del field
12. pari occorrer fare alcune attente considerazioni sulle possibili interferenze in modo che possa essere correttamente scelto il vertice pi opportuno dove collocare il Trasmettitore vicino al Ricevitore alcuni esempi sono illustrati in figura 5 ERRATO CORRETTO TX Figura 5 Esempi di soluzione corretta di casi con numero di tratte dispari Manuale di Installazione pagina 5 di 44 ERMUSA CIAS Elettronica S r l Ed 2 0 2 3 Condizioni del Terreno E sconsigliabile installare l apparato lungo tratti dove ci siano erba alta maggiore di 10 cm stagni corsi d acqua in senso longitudinale ed in generale tutti quei tipi di terreni la cui conformazione sia rapidamente variabile 2 4 Presenza di Ostacoli Le recinzioni se metalliche e pertanto molto riflettenti possono causare diversi problemi di riflessione della microonda quindi necessario adottare alcuni accorgimenti la recinzione deve essere accuratamente fissata in modo che il vento non ne provochi il movimento dove possibile la tratta non deve essere installata in parallelo alla recinzione necessario creare un angolo rispetto ad essa nel caso in cui il fascio sensibile debba essere delimitato lateralmente da due reti metalliche il corridoio tra esse non deve essere inferiore ai 5 mt in quanto il loro movimento potrebbe creare dei disturbi
13. realizzato uno strumento di Allineamento e Taratura Nella seguente immagine riportato lo schema di connessione tra la barriera ERMUSA e lo strumento STC 95 e le funzioni dei tasti e dei leds Hat per ERM USA Al connettore SIC 95 EHMUSA TX RX cavetto RCA BNC 2 oscillosc opio 3 4 22 5 21 3 6 19 1 18 g 17 9 16 10 15 11 14 12 13 Figura 13 Connettore 3M Tasto aumento Soglia intervento Buzzer Display LCD Tasto diminuzione Soglia intervento Buzzer Barra LED Tasto attivazione disattivazione Buzzer LED misura Alimentazione 13 8 V LED segnalazione Buzzer Attivato LED misura Campo rilevato Tasto apertura chiusura Loop 6 LED misura Sens RX TX LED segnalazione Loop aperto 7 LED misura VRag 19 Tasto attivazione disattivazione misure Tx Rx 2e Medusa 8 LED misura Alimentaz TX 9 V LED segnalaz misure Tx Rx 2 Medusa LED misura Alimentaz RX 5 V 21 lasto attivazione disattivazione misure modulo MEDUSA RX TX ERMO ERMUSA MINERMO TX ERMO ERMUSA MINERMO e T cavetto fornito l oscilloscopio Tasto diminuz manuale del Guadagno Manuale di Installazione pagina 15 di 44 ERMUSA CIAS Elettronica S r l Ed 2 0 4 1 1 Operazioni sul Trasmettitore Per effettuare la taratura e
14. AUDO TEST SHEET ee eene eene nnn 0 SCHEDA DI COLLAUDO TEST 5 1 Manuale di Installazione pagina 2 di 44 ERMUSA CIAS Elettronica S r l Ed 2 0 1 DESCRIZIONE 1 1 Descrizione ERMUSA un sistema a Microonde per protezioni esterne del tipo a Barriera Volumetrica Il sistema in grado di rilevare la presenza di un corpo che si muove all interno del Campo Sensibile instauratosi tra il Trasmettitore Tx ed il Ricevitore Rx I modelli disponibili del prodotto sono ERMUSA 30 Portata 30 metri da esterno ERMUSA 60 Portata 60 metri da esterno ERMUSA 80 Portata 80 metri da esterno ERMUSA 80 S Portata 80 metri da esterno La versione S dispone delle funzioni supplementari di Test Stand by e Sincronismo che consentono una pi efficace gestione dei rivelatori Per informazioni pi dettagliate consultare il paragrafo 3 3 Collegamento alla Centrale che verr descritto pi avanti nel corso del manuale Manuale di Installazione pagina 3 di 44 ERMUSA CIAS Elettronica S r l Ed 2 0 2 INSTALLAZIONE 2 1 Informazioni preliminari La diversificazione in vari modelli della barriera ERMUSA implica pi tipi di installazione e fissaggio in base alle esigenze dell utente 2 1 1 Modi di Installazione Le versioni 30 60 80 e 805 sono gi dotate d
15. E GND 5 VDC 10 INSIDE SUPPLY VOLTAGE MEASURED BETWEEN PIN 12 OF J1 AND GND VERIFICA SEGNALE RIVELATO MISURATA CON LO STRUMENTO STC 95 6 VDC 10 SIGNAL DETECTED VOLTAGE MEASURED BY STABILE STC 95 STEADY TENSIONE DI RAG MISURATA TRA IL PIN 14 DI J1 E GND AGC VOLTAGE MEASURED BETWEEN PIN 14 OF J1 AND GND TENSIONE DI SOGLIA MISURATO TRA IL PIN 8 DI J1 E GND THRESHOLD VOLTAGE MEASURED BETWEEN PIN 8 OF J1 AND GND CANALE DI MODULAZIONE SELEZIONATO MODULATION CHANNEL SELECTED misura pu essere effettuata anche con lo strumento STC 95 Itis possible to make the measure also by the STC 95 OSSERVAZIONI DELL INSTALLATORE INSTALLER COMMENTS Data installazione Installation date Firma Installatore Installer Signature LU CC LL E H O 5 O LU CC lt lt H NOTE Con la presente CIAS Elettronica dichiara che questo rivelatore d intrusione Ermusa conforme ai requisiti essenziali ed alle altre disposizioni rilevanti della Direttiva 1999 5 CE Art 3 14 3 1p 3 2 Hereby Cias Elettronica declares that this movement detector Ermusa is in compliance with the essential requirement and other relevant provisions of Directive 1999 5 EC Art 3 14 3 15 3 2 Omologazioni CEI 79 2 IMQ III livello ZIA Questo apparecchio contrassegnato in conformit alla Direttiva Europea 2002 96 EC Waste Electrical and Electronic Equipment WEEE As
16. alue is read on the display Installation Handbook page 35 to 44 ERMUSA CIAS Elettronica S r l Ed 2 0 f After having loosened the fastening screws on the mast turn the Receiver module on the horizontal plane till obtaining the maximum reading on the display 2 Repeat the pointing operation on the horizontal adjustment of the transmitter module After having obtained the best pointing lock the horizontal movement of the TX and RX modules Unlock the vertical movement of the RX module and direct it towards the top Slowly move it towards the bottom till obtaining the maximum reading on display 2 and on the LED 3 by proceeding as per the horizontal adjustment Repeat the vertical movement on the TX module After having obtained the maximum reading lock the vertical movement on modules TX and RX Press key loop 17 and check that Loop Closure LED open 18 turns OFF Check that after a recovery period of approx 2 mins the value read on display 2 reaches approx 6 V 10 and that the LED at the centre of the bar lights up Note The absolute value precision of this test 6 V isn t very important because it doesn t depend by the absolute value of microwave MW received signal but it is related to the instrument STC 95 adjustment On the contrary the stability of this test is directly related to the stability of the received microwave MW signal for this reason the instability of this test mean that
17. ato in Italia Printed in Italy CIAS Elettronica S r l Direzione Ufficio Amministrativo Ufficio Commerciale Laboratorio di Ricerca e Sviluppo Direction Administrative Office Sales Office Laboratory of Research and Development 20158 Milano via Durando n 38 Tel 39 02 376716 1 Fax 39 02 39311225 Web site www cias it E mail info cias it Stabilimento Factory 23887 Olgiate Molgora LC Via Don Sturzo n 17
18. between sections Installation Handbook page 27 to 44 ERMUSA CIAS Elettronica S r l Ed 2 0 3 CONNECTIONS 3 1 Terminal block connectors and Circuit function 3 1 1 Transmitter Circuit The following figure and tables show the terminal block and connector function present on the ERMUSA TX board DL lt I Figure 10 TERMINAL BLOCK MS1 For the connection to the Control Panel 13 8 V Power Supply positive input 13 8 V SYNC Input Output Synchronism signal only S version STBY Standby TX Input only S version TEST TestInput only S version A 8 9 Installation Handbook page 28 to 44 ERMUSA CIAS Elettronica S r l Ed 2 0 CONNECTOR J1 Connector for STC 95 Instrument Power Supply Output 13 8 V OSCILL Function Oscillator Signal OK Internal Power Supply LEDS Symbo FUNCTION D 10 Power On Green normal On D 16 Fault Red normal Off D 17 Test Enable Red normal Off JUMPERS Symbol FUNCTION Jumper for Enable Disabile LEDS Closed Enable SWITCHES Symbol FUNCTION Channel Selector 1 to 4 Installation Handbook page 29 to 44 ERMUSA CIAS Elettronica S r l Ed 2 0 3 1 2 Recelver circuit The following figure and tables show the terminal block and connector function present on the ERMUSA RX board Figure 11 For the connection to the Control Panel Term Symbol 1 13 8V Power supply Positive
19. e annulled should at the vertices of the polygon resulting from the installation of the various sections be installed two equipment with the same name i e two transmitters or two receivers It is evident that this might occur only if the number of sections is even Should it not be possible to have an even number of sections then some careful considerations must be made on interferences that might likely occur in order to find the vertex point where retained best to place the transmitter near the receiver The following pictures show some typical cases for which the most correct solution is given FIG 5 Figure 5 Right solutions for the odd section installation cases Installation Handbook page 24 to 44 ERMUSA CIAS Elettronica S r l Ed 2 0 2 3 Ground conditions It is inadvisable to install the equipment along sections with tall grass more than 10 cm ponds longitudinal waterways and all those types of grounds whose structure is rapidly mutable 2 4 Presence of Obstacles The fences are generally metallic therefore highly reflecting hence causing various problems for this reasons some precautions are suggested first of all make sure that the fence has been properly fixed in order that the wind does not move If it is possible the microwave beam sh
20. e favorevolmente adottate quando la barriera installata in modo che l intruso non possa attraversarla correndo ad esempio lungo la parete di un edificio Premere il tasto buzzer 15 fino ad ottenere l accensione del led on 16 che corrisponde all abilitazione del buzzer In assenza di movimenti nel campo di protezione verificare che il buzzer sia silenziato Se non lo fosse premere il tasto buzzer adj U 14 fino ad ottenere il suo spegnimento oe all attivazione della funzione il buzzer fosse gi silenziato agire sul tasto buzzer adj ft 13 fino ad ottenere il suo intervento intermittente quindi agire leggermente sul tasto buzzer adj U 14 fino ad ottenere lo spegnimento Manuale di Installazione pagina 18 di 44 ERMUSA CIAS Elettronica S r l Ed 2 0 r 50 mV div Effettuare le prove di attraversamento verificando prima il suono intermittente del buzzer e successivamente il suono continuo e l accensione del led D6 sulla barriera RX che indica l avvenuto rilevamento dell allarme Verificare inoltre che in assenza di movimento nel campo protetto il buzzer non entri in funzione Se ci avviene anche in modo discontinuo significa che il campo perturbato Per attraversamento di grossi bersagli pu verificarsi lo spegnimento anche del led D1 indicando in tal modo che si verificata l interruzione del segnale RF Lo strumento STC 95 dispone di un uscita RCA 23 che mediante il cavett
21. e l altro deve essere il pi breve possibile 10 metri e deve essere schermato con schermo collegato a terra Per lunghezze del cavo di sincronismo maggiori di 10 metri occorre utilizzare un circuito di ripetizione del sincronismo mod SYNC 01 Rmusa TX 71 Figura 12 3 3 3 Connessione per Stand by La funzione STBY e presente solo nella versione S per attivare la funzione di Stand by necessario collegare a GND il morsetto 8 STBY di MS1 sul trasmettitore Lo Stand by inibisce la trasmissione del dispositivo Trasmettitore 3 3 4 Connessione per Test Nelle protezioni ad Alto Rischio indispensabile che i rivelatori siano sottoposti con adeguata periodicit al Test operativo In questo modo la centrale di allarme sar in grado di riconoscere i tentativi di elusione Per attivare il Test operativo presente nella versione S procedere come segue connettere il morsetto 9 TEST di MS1 del circuito Trasmettitore a GND Se la procedura di Test andata a buon fine si attiver il rel di allarme sul circuito Ricevitore Qualora non venga utilizzata una barriera Ermusa 80 S possibile comunque effettuare il Test operativo disalimentando temporaneamente il Trasmettitore Manuale di Installazione pagina 14 di 44 ERMUSA CIAS Elettronica S r l Ed 2 0 4 ALLINEAMENTO E VERIFICA 4 1 Allineamento e Verifica con Strumento STC 95 Per facilitare l operazione di installazione delle proprie barriere Cias ha
22. eccedono i limiti indicati rivedere i relativi punti nel capitolo Allineamento e Verifica 4 Possibile Causa Possibile Soluzione Led alimentazione spento Tx e o Alimentazione 413 8 V non Verifica collegamenti Rx presente Connessioni interrotte Tensione 13 8 V non Lunghezza e o sezione cavi non Ridimensionare nuovamente le corretta e o insufficiente adeguata connessioni e o i cavi vedere paragrafo 3 2 1 Led canale spento Selezione canale errata Agendo sul selettore canali del Ricevitore impostare lo stesso canale del Trasmettitore Tx o Rx guasti Sostituire parti guaste Led allarme acceso Movimento od ostacoli nel campo Assicurarsi che non vi sia nulla protetto nel campo protetto Teste disallineate Ripetere il puntamento descritto nei paragrafi 4 1 1 e 4 1 2 VRag elevato Teste disallineate Eseguire il puntamento Ostacoli nel campo protetto Rimuovere gli ostacoli Segnale trasmesso insufficiente Controllare il Trasmettitore Circuito guasto Sostituire con apposito Kit Ricevitore a microonde guasto Sostituire il Kit Rx Contatto manomissione aperto Microinterruttore aperto Verificare la chiusura del microinterruttore Ampolla in posizione errata Verificare la posizione dell ampolla Led Guasto acceso solo circuito Guasto oscillatore BF Sostituire il Kit Tx Tx versione S Guasto oscillatore MW Sostituire il Kit Tx 5 2 Kit assistenza e loro funzione I Kit di ass
23. ella piastra di fondo snodata e sono completamente protette dall attacco degli agenti atmosferici Per il fissaggio a parete si sfrutta la STAFFA A MURO figura 2 o la STAFFA A MURO 30 figura 3 E possibile inoltre effettuare il fissaggio della barriera su un comune palo da 60 mm utilizzando la STAFFA A PALO figura 4 Per installazioni a parete la distanza minima consigliata tra la maggior sporgenza e il centro del fascio di 30 cm la lunghezza massima consigliata per questo tipo di installazione di 50m Manuale di Installazione pagina 4 di 44 ERMUSA CIAS Elettronica S r l Ed 2 0 2 2 Numero di Tratte Dovendo progettare la protezione con barriere volumetriche di un perimetro chiuso oltre alle normali considerazioni di suddivisione del perimetro in un certo numero di tratte che tengano conto delle necessit gestionali dell intero impianto occorre ricordare che sempre preferibile installare un numero di tratte pari Questa considerazione legata al fatto che le possibili interferenze reciproche tra tratte contigue vengono annullate nel caso in cui ai vertici incroci del poligono risultante dall installazione stessa vengano installati due rivelatori aventi lo stesso nome cio due trasmettitori o due ricevitori E evidente che ci pu avvenire solo nel caso che il numero delle tratte sia pari Qualora non fosse possibile disporne in numero
24. er adj 14 till it switches OFF p Carry out the crossing trials to check for the presence of an intermittent sound and then following the presence of an alarm for a continuous buzz and LED D6 light up on Receiver unit alarm for intrusion detection q Check that the buzzer is not active for no moving object into the protected field If the buzzer ring also in an intermittent manner the protection field is in some way disturbed r If the protection field is crossed by a very big object the LED D1 turns off this means an interruption of RF signal The STC 95 is provided with an RCA 23 connector which through the cable supplied allows to check the wave form of the received signal An oscilloscope any of the types present on the market is utilised for this check A good connection between the transmitting head and the receiving head produces the waveform illustrated in fig 13 o 50 mV div Y A 100 ns div Figure 13 Correct waveform Figure 14 not correct waveform excessive noise A 200 mVpp 10 A bad installation produces the waveform illustrated in fig 14 Note the noise at the tip of the square wave This means that the signal is not good Therefore repeat the pointing operations till the waveform shown in fig 13 is obtained In case of bad barrier installation the waveform will be like the one in fig 14 All the da
25. ge 34 to 44 ERMUSA CIAS Elettronica S r l Ed 2 0 4 1 1 Transmitter Test and Adjustment To align and adjust the Transmitter ERMUSA proceed as follows unscrew the specific screws to remove the front cover activate the power supply connection to MS1 terminal block Fig 9 check that the LED D10 indicating presence of mains lights up preset one of the 4 channels available through the channel selector SW1 fig 9 Connect the STC 95 instrument to the ERMUSA Tx barrier use the related flat cable 16 wires and insert it in J1 connector a Check that LED Rx Tx 1 22 is lights up If it isn t press the key 1 21 for lights up it b Press the key 0 10 a number of time as needed for lights up the LED 13 8 V 4 The voltage indicated by display 2 must be 13 8 V 10 c Press the key J 10 until the LED Tx lights up 8 The voltage indicated by display 2 must be 9 V 10 d Press the key 10 until the LED sens Rx Tx lights up 6 The voltage indicated by display 2 must be 4 5 V 10 4 1 2 Receiver Test and Adjustment To align and adjust the Receiver ERMUSA proceed as follows unscrew the specific screws to remove the front cover connect the power supply to terminals 1 and 2 of MS1 terminal block fig 10 check that the LED D 10 indicating presence of mains lights up preset one of the 4 channels available through the channel selector SW1
26. h cause false alarm Installation Handbook page 25 to 44 ERMUSA CIAS Elettronica S r l Ed 2 0 2 5 Amplitude of the Sensitive Beam The amplitude of the sensitive beam depends on the distance between the transmitter and the receiver and on the sensitivity adjustment set The figures below state the diameter half way of the sensitive beam section based on the length of the section in case of maximum and minimum sensitivity figure 7 and 8 With a medium sensibility the minimum space recommended for corner crossing is 3 5 m For wall installation the minimum distance from the wall to the centre head is 30 cm 20 Half range 8 sensible horizontal Maximum 16 zone dimension m sensitivity 14 12 10 8 6 Minimum sensitivity 2 Range m 10 20 30 40 50 60 70 80 90 100 Figure 7 Free space Horizontal dimension of the sensible beam at half range 20 Half range i 18 sensible vertical Maximum 16 zone dimension m sensitivity 14 12 10 8 6 Minimum 4 sensitivity 2 Range m 10 20 30 40 50 60 70 80 490 100 Figure 8 Free space Vertical dimension of the sensible beam at half range Note that for
27. he equipment ee eee eee eee ee e 22 esee es sette eese esos etae eese 999 220000 27 SMEECelieelet cer 28 3 1 Terminal block connectors and Circuit function 9 eee eee eee ee eese eee ee tees 2999 99999999 999 99988906 28 e Transmiter CCU lella 28 EA bia 30 3 2 Equipment connection to the Power Supply cccccccsssssssssccccssssssssccccccccsssssssccccscccssssssscccsscsssssssccsssssssscess 32 32 Connectrons tothe Power 9UDDLy ea cut as 32 3 3 Connections to the data processing Central siriani 32 3 3 1 Alarm contacts Alarm Famper Paullo 32 SVNCHIOMISMICOMMECLION a a 33 Io ss SLANGEDY COMME CU ON 33 tok CSL COMM COLON RM m 33 4 ADJUSTMENT AND 34 4 1 Adjustment and testing with STC 95 Instrument eee ee e eee eee eese eee eee tete eese sss ettet 9 sss eet eee 34 Z b Transmitter Testand aa 35 4 1 2 Receiver Test and Nd Us HIC TIE a aaa ii 35 5 MAINTENANGE Giallo 38 Sl ETR 38 5 2 Maintenance kits use 38 6 CHARACTERS HCS anaa a a a 39 GA Eechnical Characteristios sessili aaa 39 SCHEDA DI COLL
28. input 13 8 V 2 GND Power supply Negative input 0 V 3 ALLO ALLOAlarmeontactRel NC O 4 ALL1 ALL1 Alarm contact Rel NC gt S O 89 6 PT 0 Tamper contact NC bulb contact PT 1 Tamper contact NC bulb contact Connector for STC 95 Instrument PIN Symbol FUNCTION 4 GND 7 Ground O 6 Vcc Power Supply Output 1358 VE SSS O 8 Soglia Alarm threshold 300 mV 9 V 9 200mV Detected signal O 10 Rivelata Field voltage 0 O 12 5V Internal Power Supply 1 O 13 Allarme ALARM signal y OO 14 AGC Automatic Gain Control Voltage Installation Handbook page 30 to 44 ERMUSA CIAS Elettronica S r l Ed 2 0 06 _ Alarm Channel Off Red normal Off 1 1 1 JUMPERS FUNCTION Jumper for Enable Disabile LEDS Closed Enable SWITCHES Symbol FUNCTION Channel Selector 1 to 4 Installation Handbook page 31 to 44 ERMUSA CIAS Elettronica S r l Ed 2 0 3 2 Equipment connection to the Power Supply 3 2 1 Connections to the Power Supply The units must be powered with DC voltage nominal value is 13 8 V The connection between unit and the power supply must be realised with cables of correct section the cables section must be computed keeping in account connection length and unit current absorption For the very long connection case we suggest the use of a supplementary p
29. istenza sono costituiti dalla parte di elaborazione circuitale completi di parte a microonde L operazione di sostituzione molto semplice sufficiente svitare l unica vite di fissaggio e centrare il nuovo circuito nelle apposite guide di plastica presenti sul fondo del contenitore La sostituzione della parte circuitale e della cavit sia sul Trasmettitore sia sul Ricevitore non altera l orientamento della barriera e quindi non obbliga ad effettuare un nuovo puntamento Manuale di Installazione pagina 20 di 44 ERMUSA CIAS Elettronica S r l Ed 2 0 6 CARATTERISTICHE 6 1 Caratteristiche Tecniche Frequenza di lavoro In accordo con le richieste nazionali Da 20 a 500 mW P I R E Potenza massima di emissione In accordo con le richieste nazionali Modulazione On FF Duty Cycle OO __ Numero di canali 4 PORTATE e __ 3 ERMUSA 30 1 8m ERMUSA 600 Om ERMUSA 800 m J J ERMUSA 808 Om __ Tensione d alimentazione 11 5 V 138 V 148 V Corrente assorbita max RX m viglana ASMA Corrente assorbita max RX n lame __ mA Corente assorbtamaxTX Corrente assorbita max Tx In sendy am Corrente assorbita max TX con Test tivo ssm Apertura TX calotta contenitore e sposiz N C 30 VA Apertura RX calotta contenitore e sposiz N C 30 VA Contatt
30. ition of antiremoval position not vertical bulb Fault LED On BF oscillator fault Change Tx Kit only Tx S version MW oscillator fault Change Tx Kit 5 2 Maintenance kits use and function The maintenance Kits are composed by circuits equipped with microwave cavities their substitution is very easy Unlock the only one fixing screw and install the new circuit into related plastic guides present on the bottom box The circuit and cavity substitution on both transmitter and receiver heads doesn t changes the heads alignment and so no new alignment is required Installation Handbook page 38 to 44 ERMUSA CIAS Elettronica S r l Ed 2 0 6 CHARACTERISTICS 6 1 Technical Characteristics TECHNICAL CHARACTERISTICS Min Nom Max Noe Frequency 9 47 GHz to 10 60 GHz According with national rules Maximum power to emitting 20 to 500 mW According with national rules Modulation l 1l On Off Dutycycde 507 50 Channel number 1 a RANGE Ll ERMUSA30 30m IERMUSA60 lt lt lt lt 60m f o IERMUSA80 80m mE m T R DC power supply isi 115 V 138 V 148 Vz Max Current absorption amp mA Mex Current absorption RX naam 49m amp Mex Curentabsorption TX ama Oooo Max Current ab
31. itivity can miss alarm in case of little dimension intruder We suggest to adjust the min sensitivity at no less than 25 96 trimmer position which correspond at about 6 7 V Adjust the PT7 trimmer on module RX fig 10 till obtaining the required integration max clockwise The integration function act on intruder crossing speed The alarm crossing tests usually are performed with a walking person standing moving at a speed of 0 5 m s The final integration adjustment must be related to the specific site requirements Note Too low integration can cause unwanted alarms Installation Handbook page 36 to 44 ERMUSA CIAS Elettronica S r l Ed 2 0 We suggest to adjust the min integration at no less than 30 trimmer position Too much integration can miss alarm in case of running intruder We suggest to adjust the max integration at no more than 80 trimmer position Higher integration value can be adopted when the barrier can t be crossed by running intruder e g the barrier installation is along a building wall o Press key buzzer 15 untill the buzzer enabling LED buzzer On 16 lights up When there are no movements in the protection field check that the buzzer is mute If otherwise press key U buzzer adj 14 till it turns OFF If when activating the function the buzzer is already mute press key f buzzer adj 13 till an intermittent operation is obtained afterwards slightly press key U buzz
32. l apparato stesso dal suolo sia della sensibilit impostata sul ricevitore fig 9 L Altezza consigliabile per installazioni standard di 85 cm circa compatibilmente con le esigenze impiantistiche La misura da considerarsi tra il suolo e il centro dell apparecchio Con una sensibilit media la distanza minima consigliata per effettuare l Incrocio di 3 5 mt oe installate a parete figura 3 la distanza minima consigliata tra la maggior sporgenza e il centro del fascio di 30 cm 100 XM ea 100 Sensibilit Sensibilit 90 Massima minima 90 80 80 70 70 60 60 50 50 40 40 30 30 20 Altezza dal suolo 10 al centro Lunghezza 10 antenna cm zona morta m 1 2 3 4 5 6 y 8 9 10 Figura 9 Lunghezza della zona morta in prossimit degli apparati in funzione dell altezza degli stessi dal centro al suolo La seguente illustrazione mostra le zone morte in prossimit dell incrocio tra due tratte Manuale di Installazione pagina 8 di 44 ERMUSA CIAS Elettronica S r l Ed 2 0 3 COLLEGAMENTI 3 1 Morsettiere connettori e funzionalit del circuito 3 1 1 Circuito Trasmettitore Figura 10 Nelle seguenti tabelle sono indicate le funzioni delle morsettiere connettori selettori e trimmer presenti sulla scheda ERMUSA TX Morsettiera principale per le
33. nchronisation operation is required the connection between pin 7 SYNC and 2 GND of MS1 terminal block of both Transmitter It is also necessary the choice for the transmitter Master or Slave by means of the E strip see fig 12 E Closed The choice is internal synchronism the Tx is Master E Open The choice is external synchronism the Tx is Slave Remark Before connecting synchronization wires each barrier must be aligned individually Ensure that the transmitter of the barrier not being aligned is powered down The cable connecting the two transmitters must be as short as possible and not more than 10 meters If cables longer than 10 meters are required it is necessary to use the synchronisation repetition circuit mod SYNC 01 z amp MUsa TX 71 Figure 12 3 3 3 Stand by connection For the Stand by function only S version activation is required the connection to GND of pin 8 SIBY on MS1 terminal block Transmitter unit The Stand by function prevents the transmission from Tx unit 3 3 4 Test connection For high risk protection it s necessary a periodic Test for the equipments By means for these control panel will be able to detect tamper action For the Test function only S version activation it is required the connection to GND of pin 9 TEST on MS1 terminal block of Transmitter unit If the test procedure is correct the Alarm on Receiver unit will be activated Using other model them S version its possible
34. o allarme guasto TX N C 100 mA Imax Contatto allarme intrusione RX N C 100 mA imas SEGNALAZONILUMNOSE T_T TO Presenza alimentazione led verde TX O Test da centrale led rosso TX Of Segnalazione Guasto led rosso TX Lo Presenza alimentazione led verde RX o On Riconoscimento canale led verde RX J O Stato di allarme intrusione led rosso RX Of Regolazione di sensibilit RX 1 J trimmer Regolazione di integrazione RX Lo y trimmer Peso TX og Peso RX d 400g 50 Temperatura di lavoro 25 C 194999 IP 55 mod 30 mod 60 mod 80 S Manuale di Installazione pagina 21 di 44 ERMUSA CIAS Elettronica S r l Ed 2 0 1 DESCRIPTION 1 1 Description The ERMUSA equipment is a microwave system for outdoor indoor volumetric barrier protection Such a system can detect the presence of somebody or something moving within the sensitive field present between the transmitter Tx and the receiver Rx The ERMUSA system types availabile ERMUSA 30 Range 30 meters for outdoor use ERMUSA 60 Range 60 meters for outdoor use ERMUSA 80 Range 80 meters for outdoor use ERMUSA 80 S Range 80 meters for outdoor use The S version has the built in supplementary functions Test Stand by and Synchronism for a more effective detectors management For more detailed information see this handbook a
35. o in dotazione consente di verificare la forma d onda del segnale ricevuto Tale verifica richiede un oscilloscopio qualsiasi modello presente sul mercato Un buon collegamento tra testa trasmittente e testa ricevente mostra una forma d onda come indicato in figura 13 50 mV div 100 ps div 100 ns div Figura 14 Forma d onda non corretta eccessivo rumore Figura 13 Forma d onda corretta A 200 mVpp 10 Un cattivo collegamento mostra una forma d onda come indicato in fig 14 Si osservi come sulle cuspidi dell onda quadra sia presente il rumore Ci sta a significare che il segnale ricevuto non ottimale In questo caso ripetere le operazioni di puntamento fino ad ottenere la forma d onda di fig 13 Tutti i dati relativi alle misure effettuate in impianto vanno riportati sulle schede di collaudo che sono in dotazione ad ogni barriera Ci render pi semplice l operazione di assistenza Rimontare le calotte in plastica bloccandole uniformemente con le apposite viti in modo da ottenere una buona tenuta all acqua Manuale di Installazione pagina 19 di 44 ERMUSA CIAS Elettronica S r l Ed 2 0 5 MANUTENZIONE E ASSISTENZA 5 1 Ricerca Guasti In caso di falsi allarmi verificare i parametri riscontrati durante l installazione che saranno stati registrati nell apposita scheda di collaudo allegata e se si riscontrano delle variazioni che
36. ouldn t be placed in parallel to a metallic fence is necessary to create a corner with it metal fences placed behind the equipment might cause distortions to the sensitive beam especially and might cause movement detection in unexpected spots with subsequent likely generation of false alarms n case of Mw barrier should be installed in a corridor between two metallic fences the width of the corridor should be necessary not less to 5 m Along the section within the area of the protection field are allowed pipes poles or similar e g lamp posts as long as their dimensions with respect to the protection beam are not too excessive The trees hedges bushes in general need very great attention if near or within the protection beams These obstacles vary in size and position in fact they grow and they can be moved by the wind Therefore it is absolutely inadvisable to tolerate the presence of the cited obstacles within the p VAN W ENYE AC e iN usti Figure 6 It is possible to tolerate the presence of these elements near the protection sections only if their growth is limited through routine maintenance and if their movement is stopped through containment barriers Various Obstacles might be present along the protection sections For them there is the need to make the same considerations and take the same necessary precautions adopted for the above cases These create dead zones not protected and hypersensitive zones whic
37. ower supply For the power supply connection 13 8 V e GND to make connect pin 1 and 2 on the terminal strep MS1 of the Tx and Rx circuit The cable must be shielded type 3 3 Connections to the data processing Central The connection cables to the Central must be of shielded type The connections are made up by contact normally closed and free of electrical voltage they are as follows Alarm Tamper Fault On the Transmitter only S version unit are also present inputs for the following functions activation Synchronism Tx Stand By Tx Test Tx 3 3 1 Alarm contacts Alarm Tamper Fault The Alarm and Fault outputs are made of static relays contacts with 100 mA 12 V max capability and total internal resistance of 35 Ohm The Tamper output is made of Microswitch contact and a Bulb contact with 100 mA max capability The outputs are activated by the following reasons Alarm output 1 Intrusion alarm on Receiver 2 Channel alarm on Receiver Tamper output 1 Opening of microwave head Tx or Rx 2 Changing head position bulb contact Tx or Rx Fault output 1 Fault BF oscillator Tx 2 Fault RF oscillator Tx Installation Handbook page 32 to 44 ERMUSA CIAS Elettronica S r l Ed 2 0 3 3 2 Synchronism connection SYNC only S version it is used for the synchronization of two transmitter mounted somehow near between them so they can work at the same modulation frequency For the sy
38. ponde alla minima sensibilit Le prove di attraversamento vengono di norma effettuate da una persona che cammina in posizione eretta ad una velocit di 0 5 m s Si consiglia di iniziare le prove con una impostazione del 50 96 di sensibilit corsa del trimmer ed una regolazione del 40 96 di integrazione corsa del trimmer La regolazione di sensibilit deve essere effettuata per soddisfare le esigenze di protezione dello specifico sito N B Una Sensibilit troppo elevata puo causare allarmi impropri oi consiglia di non adottare sensibilit maggiori del 75 corsa del trimmer che corrisponde a circa 1 6 V Una Sensibilit troppo bassa puo impedire la rivelazione di un intruso di dimensioni ridotte Si consiglia di non adottare sensibilit inferiori al 25 96 corsa del trimmer che corrisponde a circa 6 7 V Regolare il trimmer PT7 fig 10 fino ad ottenere l integrazione desiderata massima in senso orario L Integrazione agisce sulla Velocit di attraversamento Le prove di attraversamento vengono di norma effettuate da una persona che cammina in posizione eretta ad una velocit di 0 5 m s La regolazione di integrazione deve essere effettuata per soddisfare le esigenze di protezione dello specifico sito N B Una regolazione di Integrazione eccessivamente bassa puo causare allarmi impropri Si consiglia di non adottare un integrazione superiore al 80 corsa del trimmer Integrazioni di valore maggiore possono esser
39. recinzioni metalliche poste dietro gli apparati possono provocare talvolta distorsioni del fascio sensibile e quindi dare luogo a falsi allarmi Gli alberi le siepi i cespugli la vegetazione in genere richiede una grande attenzione qualora ve ne sia in prossimit o entro i fasci di protezione Questi ostacoli sono elementi variabili sia come dimensione che come posizione possono infatti crescere ed essere mossi dal vento I Manuale di Installazione pagina 6 di 44 ERMUSA CIAS Elettronica S r l Ed 2 0 Pertanto sconsigliabile tollerare la presenza di detti ostacoli entro le tratte di protezione E possibile tollerarne la presenza solo a patto che la loro crescita venga limitata mediante una metodica manutenzione e che il loro movimento venga impedito mediante barriere di contenimento All interno del fascio di protezione altres tollerabile la presenza di tubi pali ed Ostacoli vari illuminazione camini ecc purch non presentino dimensioni eccessive all interno dei lobi di protezione Questi infatti sono la causa di Zone d Ombra non protette e di Zone di Ipersensibilit fonti di falsi allarmi 2 5 Ampiezza dei Fasci Sensibili L ampiezza del Campo Sensibile funzione sia della distanza tra trasmettitore e ricevitore sia dalla regolazione di sensibilit impostata grafici seguenti forniscono la dimensione a met tratta del Fascio Sensibile in funzione della lunghezza della tratta nel caso di sensibilit
40. sicurarandosi che questo prodotto sia smaltito in modo corretto l utente contribuisce a prevenire le potenziali conseguenze negative per l ambiente e la salute kr Il simbolo sul prodotto o sulla documentazione d accompagnamento indica che questo prodotto non deve essere trattato come rifiuto domestico ma deve essere consegnato presso l doneo punto di raccolta per il riciclaggio d apparecchiature elettriche ed elettroniche Disfarsene seguendo le normative locali per lo smaltimento rifiuti Lo smaltimento abusivo punito con le sanzioni previste dalla legislazione nazionale vigente Il prodotto pu essere riconsegnato al distributore installatore a fine vita in occasione di un nuovo acquisto This product is marked in compliance with the European Directive 2002 96 EC Waste Electrical and Electronic Equipment WEEE The correct disposal of the product will prevent potential negative consequences for the environment and the human health Ee The symbol mmm on the product or into the annexed documentation indicates that this product does not have to be dealt like domestic refusal but must be delivered near the suitable point of collection for the recycling of electrical and electronic equipment The illicit disposal will be endorsed according to local regulations At the end of operative life the product can be given back to the vendor installation organization in occasion of a new purchase Copyright CIAS Elettronica S r l Stamp
41. sorption TX in sandeya et mA Mex Current absorption TX Test active SM TX front cover and out of position N C Th 830 VA RX front cover and out of position N C 30VA Pmax Failure Alarm contact TX N C o oA Ima Intrusion Alarm contact RX N C Lo 1 100 mA Ima ED ee ee E Mains presence TX Green LED i T S n Test from Central TX red LED Falue TX redLED PE Mains presence RX Green LED Eo lO Channel identification RX Green LED Intrusion Alarm status RX red LED Sensitivity tuning RX o trimmer Integration tuning RX trimmer Weight TX eg J Weight RX Og J 90 Operating Temperature AH 55707 3 Box protection level IP 55 mod 30 mod 60 mod 80 S The manufacturer declares that the operational working temperatures for this device are included within the range 35 C 65 C Installation Handbook page 39 to 44 ERMUSA SCHEDA DI COLLAUDO TEST SHEET CIAS ERMUSA TX NUMERO DI SERIE SERIAL NUMBER Cliente Customer Indirizzo Address Barriera Barrier N VALORI MISURATI SUL TRASMETTITORE MEASURED VALUES ON THE TRASMITTER VALORI MISURATI MISURE VALORI TIPICI MEASURED VALUES MEASUREMENTS STANDARD INSTALLAZIONE MANUTENZIONE INSTALLATION MAINTENANCE TENSIONE DI ALIMENTAZIONE MISURATA TRA PIN 4 6 DI J1 PIN 4 GND
42. t the paragraph Connection to the Data Processing Central Installation Handbook page 22 to 44 ERMUSA CIAS Elettronica S r l Ed 2 0 2 INSTALLATION 2 1 Preliminary Information Due to the various types of ERMUSA barrier there are some different kinds of installation and fixing unit types related to user requirements 2 1 1 Installation types The 30 60 80 e 80S versions are equipped with a knuckle bottom board and are environment conditions fully protected The wall installation requires the WALL ADAPTER see figure 2 or the WALL ADAPTER 30 see figure 3 It is also possible to install the barrier unit on a standard 60 mm pole using the POLE ADAPTER see figure 4 If the barriers are installed on a wall fig 3 the min suggested distance from the max overhang and the centre beam is 30 cm and the maximum suggested length from Tx and Rx is 50m Installation Handbook page 23 to 44 ERMUSA CIAS Elettronica S r l Ed 2 0 2 2 Number of Sections Having to design protection of a closed perimeter with volumetric barriers besides having to split the perimeter within a certain number of sections that take into account the management need of the entire plant it must be remembered that it is always preferable to install an even number of sections This consideration is bound to the fact that the likely reciprocal interferences between adjacent sections ar
43. ta concerning the tests made on the plant must be reported on the test sheets supplied for each barrier This will make the servicing operations easier to carry out t Place the front cover cap back again and regularly fasten it with the screws provided in order to obtain good water proofing Installation Handbook page 37 to 44 ERMUSA CIAS Elettronica S r l Ed 2 0 5 MAINTENANCE 5 1 Troubleshooting In case of false alarm check the parameters recorded during the installation phase on attached testing form if there are divergences with permitted limits check again the related points in chapter Adjustment and Testing 4 Power Supply LED Off No Power Check connection Tx and or Rx Cable disconnected 13 8 V not correct and or not Length and or cable section Modify connection and or sufficient see par 3 2 1 not proper cable Channel LED off Channel selection wrong Set the same channel on Tx Tx or Rx fault and Rx Change circuit Tx or Rx Alarm LED on Movement or obstacle in the Ensure that nothing 1s in the protected field field Heads not aligned Remake the alignment see par 4 1 1 or 4 1 2 VRag High Heads not aligned Do the alignment Obstacle in the field Remove obstacles Low transmitter signal Check Tx Fault circuit Change Rx Kit MW receiver fault Change Rx Kit Tamper relay open Micro switch open Check micro swith Antiremoval bulb in wrong Check pos
44. the ERMUSA equipment the sensitivity regulation to be considered for obtaining the dimensions of the sensitivity beams half way of the section is that of the alarm threshold The higher the threshold the lower the sensitivity and vice versa Installation Handbook page 26 to 44 ERMUSA CIAS Elettronica S r l 2 6 Length of the Dead Zones near the equipment Ed 2 0 The length of the dead zones near the equipment is based on the distance of the equipment from ground on the sensitivity set on the receiver figure 8 With regard to the considerations stated above and based on plant requirements the equipment must be installed at a certain height from ground In mean plant the height must be 85 cm from the ground and the centre of the equipment If the barriers are installed on a wall fig 3 the min suggested distance from the max overhang and the centre beam is 30 cm 100 90 80 70 60 50 40 30 20 10 100 Maximum Minimum sensitivity sensitivity 9 80 70 60 50 40 30 Antenna 20 centre height Dead Zone 10 from ground cm lenght m 1 2 3 4 5 6 7 8 9 10 Figure 9 Dead zone length near the equipment versus installation height From the ground and the centre of the equipment The next figure shows the corner crossing overlap
45. the RF received signal is in some way perturbed in this case is necessary to check for the absence of moving object into the protected area or check if the received signal is too weak and so affected by large amount of noise In case of uncertainty check the real working condition by means of a scope connected to RCA connector of STC 95 see point S Press key f 10 till LED V Rag Rx 7 lights up Check that a voltage value within 2 5 6 5 V is read on the display This AGC voltage value is directly proportional to the distance between the transmitting and receiving heads m Press key 10 till the Sensitivity Measurement LED sens Rx Tx 6 lights up Operate on the PT1 trimmer present in module RX fig 10 till a value within 0 5 and 9 5 V 5 is read on the display Note that the value of 0 5 V corresponds to the maximum sensitivity and that value 9 5 V corresponds to the minimum sensitivity The alarm crossing tests usually are performed with a walking person standing moving at a speed of 0 5 m s We suggest to start this tests with the sensitivity adjusted at 50 trimmer position and the integration adjusted at 40 96 trimmer position The final sensitivity adjustment must be related to the specific site requirements Note Too much sensitivity can cause unwanted alarms We suggest to adjust the max sensitivity at no more than 75 trimmer position which correspond at about 1 6 V Too low sens
46. ti d allarme Allarme Guasto ManomISsione ieri 13 5 2 lillo 14 Io COMMESSIONG pei Sand bynoi 14 SL MEE Doris cio cM IE T T umm 14 4 ALLINEAMENTO E VERIFICA erret reset te tnter tese sess 15 4 1 Allineamento e Verifica con Strumento STC 95 4 99 99999 99999 999999 99 99999 999999 9 9999 999999 99668990 15 Z b Operazioni Sul Trasmettitore ci 16 4 1 2 Operazioni sul R16 e VICOEE nai ini cado ua is 16 5 MANUTENZIONE E ASSISTENZA 1 eere eene rei irene 20 5 Ricerca E M 20 5 2 Kitassistenza loro funzione sila 20 6 CARATTERISTICHE alli cca i 21 601 Caratteristiche Tecniche onnie aincoa eeraa ea eA SEE EO L 21 Manuale di Installazione pagina 1 di 44 ERMUSA CIAS Elettronica S r l Ed 2 0 I DESCRIPTION Me 22 LS Description aa aa aaa a aaraa a a Oaa NRI RR USENET 22 ME INSTALLA TON canca 23 2 1 Information nali 23 LE etat Patton DUE A A 23 PAP MEDII 24 2 9 Ground Conditions sicir eee ana 25 Presenceor Obstaclesaaliil a 25 2 9 Amiphitude ot the Sensitive BAM 26 26 Length of the Dead Zones near t
47. to test the microwave barrier temporary switching off the transmitter Installation Handbook page 33 to 44 ERMUSA CIAS Elettronica S r l Ed 2 0 4 ADJUSTMENT AND TESTING 4 1 Adjustment and testing with STC 95 Instrument For the Microwave Barrier adjustment and testing CIAS gives the availability of a dedicated instrument with the intention to facilitate installation operation and operator activity support The following figure 12 shows the CIAS STC 95 instrument with function explanations The fig 12 shows also the STC 95 interconnection scheme to barriers CIAS ERMUSA EHMUSA Hat cable Hat cable to ERMUSA J1 connector Tx Rx cable Oscillosc ope Figure 13 LCD Display Decreasing threshold Buzzer activation key 6 Check Sens RX RFTXLED 18 OpenloopLEDindication 7 AGC LED check 19 Activation deactivation tests key TX RX 2 and Medusa 8 Powersupply LED test TX 9 V 20 Testindication LED RX TX2 Power supply LED test RX 5 V 21 Measurement activation deactivation key ES TX RX 1 MEDUSA ERMO ERMUSA MINERMO 10 Tests selection key 22 Test indication LED TX RX 1 MEDUSA ERMO ERMUSA MINERMO Manual increasing gain key RCA for scope connection with supplied M Manual decreasing gain key Installation Handbook pa
48. ul selettore canale lo stesso canale impostato sulla testa trasmittente posizionando opportunamente il selettore SW1 Effettuare la interconnessione tra lo strumento STC 95 e la barriera ERMUSA RX come indicato in figura 13 Inserire il connettore a 16 pin nel connettore J1 presente sul circuito ricevitore figura 11 a Verificare che il led Rx Tx 1 22 sia acceso Qualora fosse spento premere il tasto 4 21 per accenderlo b Premere il tasto 10 fino ad accendere il led 13 8 V 4 La tensione letta sul display 2 dovr essere 13 8 V 10 96 Portarsi sulla parte posteriore della testa ricevente ed accertarsi che la tratta sia libera da ostacoli in movimento Se il preventivo puntamento a vista degli apparati stato eseguito opportunamente si deve verificare sul ricevitore l accensione del led D1 relativo al riconoscimento del canale Manuale di Installazione pagina 16 di 44 ERMUSA CIAS Elettronica S r l Ed 2 0 Allo scopo di ottimizzare il collegamento si proceda all effettuazione del puntamento elettronico nel seguente modo O Verificare che il led on 16 sia spento Qualora fosse acceso premere il tasto buzzer 15 per spegnerlo disattivando in tal modo il buzzer interno al STC 95 2 Verificare che il led open 18 sia acceso Qualora fosse spento premere il tasto Loop 17 per accenderlo ottenendo in tale modo l apertura del LOOP Premere