1. Choose a fixing point e g wall that is sufficiently resistant and secure for assembling the manometer Establish the height at which the manometer is to be mounted so as not to not constitute a danger and or hindrance to people or objects Make two holes in the wall to fit the plugs supplied 6 mm Screw in the manometer bracket using the two screws supplied Mount the manometer onto the bracket using the screw and nut ref 4 and ref 5 Adjust inclination before blocking Connect one end of the coil tube to the plug on the back of the manometer and the other end to one of the cuff tubes Connect the other cuff tube to the bulb with the valve ASSEMBLY INSTRUCTIONS DM367 pun sou Insert the telescopic tube ref 5 into the wheeled stand ref 6 Connect the two parts using the screw ref 8 and seal ref 7 Tighten the screw ref 8 using the wrench supplied ref 9 Insert the manometer ref 10 into the upper rod of the telescopic tube applying pressure in a downwards direction Adjust manometer inclination using the screw and nut supplied Adjust the stand height using the adjustment ring ref 4 Connect one end of the coil tube to the plug on the back of the manometer and the other end to one of the cuff tubes Connect the other cuff tube to the bulb with the valve ASSEMBLY INSTRUCTIONS DM362 1 NOUAW N e MA DM344 349 361 362 366 367 370 02 A eng ita indd 11 e 04 05 12 10 18 Choose a fixing point e
2. Desk aneroid sphygmomanometer INTRODUCTION Thank you for having chosen a LOGIKO aneroid sphygmomanometer by Moretti The LOGIKO sphygmomanometers by Moretti are designed and built to meet all your demands for safe practical correct use This manual provides some suggestions as to how to correctly use the device you have chosen and gives some valuable advice for your safety Please read through the manual carefully before using the aneroid sphygmomanometer Contact your retailer directly for questions or further assistance INTENDED PURPOSE The LOGIKO aneroid sphygmomanometers by Moretti are devices used to measure blood pressure They are based on the auscultatory technique according to the Riva Rocci Korotkoff method GENERAL DESCRIPTION The air pressure within the cuff needed to take the measurement is created using a bulb The bleed valve allows for fine regulation of the air flow allowing for measurement Each manometer has a graduated scale with a measurement range from to mmHg mmHg millimetres of mercury marked out into 2 mmHg notches and greater notches every 10 mmHg for easy reading Reading accuracy for the whole range is 3 mmHg With this system both the SYSTOLIC and DIASTOLIC pressure are measured WHAT IS BLOOD PRESSURE Blood pressure is the pressure exercised by the blood on the blood vessel walls The maximum arterial pressure during the cardiac cycle is defined as SYSTOLIC pressure The lowest arter
3. this is your peak SYSTOLIC pressure When these beats cease being recognisable you have your lowest DIASTOLIC pressure After having obtained both pressure readings open the bleed valve completely to quickly empty the air chamber of all residual pressure Now remove the phonendoscope and cuff Do not keep the cuff inflated for too long MA DM344 349 361 362 366 367 370 02 A eng ita indd 9 e 04 05 12 10 18 10 ENGLISH WARNINGS FOR MEASURING BLOOD PRESSURE Generally speaking you should always use the left arm Uncover your arm remove all clothing from it Avoid all activity prior to taking the measurement Rest for 5 to 10 minutes prior to measuring blood pressure Do not talk eat drink or move whilst taking your blood pressure Do not press the head of the phonendoscope with your fingers This could affect the blood pressure reading Always measure blood pressure at the same time Always record the time and date of measurement CARE AND MAINTENANCE The LOGIKO devices by Moretti are CE marked and carefully checked before being released for sale Each sphygmomanometer is calibrated and subjected to a final thorough control Before each use while resting check that the needle on the aneroid sphygmomanometer dial is within the tolerance range permitted of 3 mmHg this can be noted by the greater marking of the graduated scale slightly above and below zero Appliances out of this tolerance range must be re
4. E CURA dispositivi della linea LOGIKO by Moretti al momento dell immissione in commercio sono controllati accurata mente e provvisti di marchio CE Ogni sfigmomanometro viene calibrato e sottoposto ad un controllo finale completo al 100 Prima di ogni uso in condizioni di riposo verificare che la lancetta sul quadrante dello sfigmomanometro aneroide sia posizionata all interno della fascia di tolleranza ammessa di 3mmHg identificabile tramite una maggiore marcatura della scala graduata leggermente sopra e sotto lo zero Apparecchi fuori tolleranza di 3 mmHg devono essere ricalibrati Consultare il proprio rivenditore per una assistenza tecnica qualificata In caso di ripa razione devono essere utilizzati soltanto ricambi ed accessori originali Prestare molta attenzione ai seguenti fattori La pressione non deve assolutamente superare 300 mmHg Non lasciare il dispositivo in ambienti umidi Non far cadere il dispositivo in caso contrario fare riverificare sempre il corretto funzionamento da un laboratorio autorizzato Non lascire il dispositivo all esposizione diretta dei raggi solari Tenere lontano da qualsiasi fonte di calore PULIZIA MANOMETRO Utilizzare esclusivamente un panno morbido e asciutto MONOPALLA CON RUBINETTO Utilizzare esclusivamente un panno morbido inumidito e successivamente asciu gare bene BRACCIALE Per una corretta pulizia del bracciale si consiglia di togliere la camera d aria al
5. g a wall that is sufficiently resistant and secure for mounting the manometer Establish the height at which the manometer is to be mounted so as not to constitute a danger and or hindrance to people or objects Dismantle the rear bracket of the basket ref 2 acting on the internal screw Make two holes in the wall to fit the plugs supplied 6 mm Screw in the manometer bracket using the two screws supplied Re assemble the manometer onto the bracket using the internal screw Adjust angle before blocking Connect one end of the coil tube to the plug on the back of the manometer and the other end to one of the cuff tubes Connect the other cuff tube to the bulb with the valve e 12 DM366 DESK ANEROID SPHYGMOMANOMETER W BASKET 49 40 LL DM367 ANEROID SPHYGMOMANOMETER STAND TYPE W TANK K e MA DM344 349 361 362 366 367 370 02 A eng ita indd 12 ENGLISH DM361 ROUND WALL MOUNTED ANEROID SPHYGMOMANOMETER W BASKET Wall mounted manometer back Basket Coil connection tube Screw Nut Adjustment ring Telescopic tube 5 leg stand with wheels Seal Screw Wrench Stand type manometer 1 2 3 4 5 6 7 8 9 10 11 12 Wall mounted manometer back Basket Coil connection tube Adjustment ring Telescopic tube 5 leg stand with wheels Seal Screw Wrench Stand type manometer LOU B W D e 04 05 12 10 18 ill ENGLISH 13 WARRANTY This pro
6. pressione arteriosa variare con la pressione atmosferica ed notevolmente influenzata ad esempio da carichi fisici eccitabilit emotiva stress pasti medicinali alcool fumo et ecc Si raccomanda di scrivere le misurazioni quotidiane in modo tale da consultare un medico per definire in modo appropriato un valore di pressione normale per il proprio organismo La pressione del sangue varia con l et quindi necessario consultare il medico per definire una pressione normale per voi In nessun caso dovrete modificare il dosaggio di eventuali farmaci prescritti dal medico NORME E DIRETTIVE DI RIFERIMENTO Gli sfigmomanometri LOGIKO by Moretti sono costruiti in conformita alla vigente norma EN 1060 1 2 EN 1060 1 Sfigmomanometri non invasivi requisiti generali EN 1060 2 Sfigmomanometri non invasivi requisiti supplementari per sfigmomanometri meccanici AVVERTENZE PER L UTILIZZO Per un utilizzo corretto del dispositivo fare riferimento attentamente al presente manuale Seguire sempre le in dicazioni riguardanti il prodotto da voi acquistato Tenere il dispositivo sempre lontano dalla portata dei bambini Non portare mai la pressione oltre 300mmHg MA DM344 349 361 362 366 367 370 02 A eng ita indd 2 e 04 05 12 10 18 ITALIANO 3 MONTAGGIO GENERALE DELLE PARTI SFIGMOMANOMETRO ANEROIDE A 2 TUBI Collegare un tubo della camera d aria al manometro e l altro tubo alla monopalla con rubinetto di regolazione de
7. 05 12 10 18 Distribuito da Distributed by Via Bruxelles 3 Meleto 52022 Cavriglia Arezzo 4 Tel 39 055 96 21 11 info morettispa com Fax 39 055 96 21 200 www morettispa com
8. 6 mm Avvitare la staffa del manometro al muro tramite le due viti in dotazione Rimontare il manometro sulla staffa tramite la vite interna e prima di bloccarlo regolare l angolazione Collegare una parte del tubo a spirale all attacco presente sul retro del manometro e l altra parte ad uno dei tubi del bracciale Collegare l altro tubo del bracciale alla monopalla con rubinetto SNOUAW N DM344 349 361 362 366 367 370 02 eng ita indd 5 e 04 05 12 10 18 Ess i i e 6 ITALIANO DM366 SFIGMOMANOMETRO ANEROIDE DM361 SFIGMOMANOMETRO ANEROIDE SU STATIVO C CESTELLO ROTONDO DA PARETE C CESTELLO 16 1 Manometro da parete retro 2 Cestello 3 Tubo di collegamento a spirale 8 4 Vite 5 Dado 6 Ghiera di regolazione 49 7 Tubo telescopico 09 8 Base 5 gambe e ruote e L0 9 Guarnizione 10 Vite DM367 SFIGMOMANOMETRO ANEROIDE 11 Chiave SU STATIVO C VASCHETTA 12 Manometro da stativo 1 Manometro da parete retro 2 Cestello 3 Tubo di collegamento a spirale 4 Ghiera di regolazione 5 Tubo telescopico 6 Base con 5 gambe e ruote 7 Guarnizione 8 Vite 9 Chiave 10 Manometro da stativo MA DM344 349 361 362 366 367 370 02 A eng ita indd 6 e 04 05 12 10 18 ITALIANO 7 GARANZIA Il prodotto garantito 2 ANNI dalla data di acquisto Il distributore si riserva il diritto di riparare o sostituire le parti affette da difetti di fabbricazione o nei materiali usati senza nessuna spesa per il client
9. BLY OF PARTS DOUBLE TUBE ANEROID SPHYGMOMANOMETER Connect one tube of the air chamber to the manometer and the other tube to the bulb with the pressure regulation valve SINGLE TUBE PALM ANEROID SPHYGMOMANOMETER Connect the tube of the air chamber to the relevant plug on the palm aneroid sphygmomanometer DOUBLE TUBE PALM ANEROID SPHYGMOMANOMETER Connect one tube of the air chamber to one of the two plugs on the palm sphygmomanometer Connect the other tube to the remaining plug on the sphygmomanometer N B To assemble the desk and wall mounted sphygmomanometer please refer to the relevant additional instructions provided with this manual LOGIKO sphygmomanometers are supplied with standard adult cuffs arm circumference from 26 to 36 cm The following cuffs are also available to order Children s cuff arm circumference from 18 to 26 cm Obese cuff arm circumference from 36 to 46 cm The palm aneroid sphygmomanometer DM344 is always supplied as a kit containing all 3 cuff types children adult and obese Before using the sphygmomanometer you need to choose the right cuff as this will help guarantee greater accuracy in measuring your blood pressure Please contact you retailer if in doubt as to which cuff to use HOW TO USE The user should be in a warm place Clothing must be removed from the left arm Sit at a table or desk where it is easier to rest your arm Position your elbow on the table so that it is approximate
10. LOGIKO SFIGMOMANOMETRI AD ANEROIDE MANUALE DI ISTRUZIONI ANEROID SPHYGMOMANOMETERS INSTRUCTION MANUAL Fax 39 055 96 21 200 www morettispa com info morettispa com MORETTI S P A Via Bruxelles 3 Meleto MORETTI 52022 Cavriglia Arezzo Tel 39 055 96 2111 MA DM344 349 361 362 366 367 370 02 A_04 2011 MA DM344 349 361 362 366 367 370 02 A eng ita indd 1 e 04 05 12 10 i r e 2 ITALIANO Dispositivo Medico di classe 1 con funzioni di misura D Lgs 24 02 97 n 46 attuazione della direttiva CEE 93 42 e successive modifiche CODICI Sfigmomanometro aneroide palmare kit 3 bracciali Sfigmomanometro aneroide palmare a 2 tubi standard Sfigmomanometro aneroide da parete con cestello Sfigmomanometro aneroide da parete con vaschetta Sfigmomanometro aneroide su stativo con cestello Sfigmomanometro aneroide su stativo con vaschetta Sfigmomanometro aneroide da tavolo INTRODUZIONE Grazie per aver scelto uno sfigmomanometro aneroide della linea LOGIKO by Moretti Gli sfigmomanometri LOGIKO by Moretti sono stati progettati e realizzati per soddisfare tutte le vostre esigenze per un utilizzo pratico corretto e sicuro Questo manuale contiene dei piccoli suggerimenti per un corretto uso del dispositivo da voi scelto e dei preziosi consigli per la vostra sicurezza Si consiglia di leggere attentamente la totalit del presente manuale prima di usare lo sfigmomanometro aneroide In caso di dubbi vi preghi
11. TALIANO 5 PARTI DI RICAMBIO ACCESSORI Per le parti di ricambio e gli accessori consultare il catalogo generale MORETTI N B La seguente tabella informa sul corretto ambito di utilizzazione del bracciale TIPO DI BRACCIALE CIRCONFERENZA DELL ARTO IN CM Bambini 18 26 Adulti 26 36 Obesi 36 46 ISTRUZIONI DI MONTAGGIO DM366 Inserire il tubo telescopico rif 7 nella base con ruote rif 8 Collegare le due parti tramite la vite rif 10 e la guarnizione rif 9 Avvitare e stringere bene la vite rif 10 con la chiave in dotazione rif 11 Inserire il manometro rif 12 nell asta superiore del tubo telescopico facendo pressione verso il basso Regolare l inclinazione del manometro tramite la vite e dado rif 4 e rif 5 Regolare l altezza dello stativo tramite la ghiera di regolazione rif 6 Collegare una parte del tubo a spirale all attacco presente sul retro del manometro e l altra parte ad uno dei tubi del bracciale Collegare l altro tubo del bracciale alla monopalla con rubinetto NOUR WN o ISTRUZIONI DI MONTAGGIO DM361 1 Determinare un punto di fissaggio ad esempio una parete sufficientemente resistente e sicura per il montaggio del manometro 2 Stabilire l altezza di montaggio del manometro in modo tale da non determinare pericolo e o ostacolo a persone e cose 3 Praticare due fori nel muro adeguati per i tasseli in dotazione 6 mm e 4 Avvitare la staffa del manometro al muro tramite le due viti in dota
12. amo di contattare il rivenditore il quale sapr aiutarvi e consigliarvi correttamente DESTINAZIONE D USO Gli sfigmomanometri aneroidi della linea LOGIKO by Moretti sono dispositivi per la misurazione della pressione del sangue e lavorano in modo auscultatorio secondo il metodo Riva Rocci Korotkoff DESCRIZIONE GENERALE La pressione d aria nel bracciale necessaria per la misurazione viene creata mediante una monopalla La valvola di sfiato permette una fine regolazione dell uscita dell aria dal bracciale consentendo la misurazione Ogni manometro ha una scala di lettura con un campo di misurazione da a 300 mmHg mmHg millimetri di mercurio con suddivisione di 2 mmHg e tacche maggiori ogni 10 mmHg per una facile lettura La precisione di lettura in tutto il campo di 3 mmHg Con questo sistema viene misurata sia la pressione SISTOLICA che la pressione DIASTOLICA CHE COSA E LA PRESSIONE DEL SANGUE La pressione sanguigna la pressione esercitata dal sangue sulle pareti dei vasi sanguigni La pressione massima nelle arterie durante il ciclo cardiaco definita come pressione SISTOLICA mentre la pressione piu bassa de finita come pressione DIASTOLICA QUAL UNA NORMALE PRESSIONE DEL SANGUE necessario sapere che la pressione arteriosa sottoposta a forti fluttuazioni Il livello della pressione arte riosa dipende da molti fattori Generalmente la pressione arteriosa pi bassa in estate e pi alta in inverno La
13. calibrated Consult your retailer for qualified technical assistance Only original replacement parts and accessories must be used for repairs Pay careful attention to the following Pressure must not exceed 300 mmHg Do not leave the device in damp places Do not drop the device should it fall always ensure that an authorised laboratory checks that the device is functioning correctly Do not leave the device in direct sunlight Keep away from all heat sources CLEANING MANOMETER Only use a soft dry cloth BULB WITH VALVE Only use a soft damp cloth and then dry thoroughly CUFF To correctly clean the cuff remove the air chamber then wash the cuff using warm water and neutral soap AIR CHAMBER Wash with warm water and neutral soap taking care not to allow the water to enter Should a little water enter the air chamber allow to dry well before use by arranging the tubes pointing downwards to allow the water to drain out PHONENDOSCOPE OPTIONAL Only use a soft damp cloth and then dry thoroughly For the remaining parts use warm water and neutral soap Dry well GENERAL WARNINGS Do not use the following product for purposes other than that defined by this manual MORETTI S P A refuses all liability for damages caused by improper use of the device or by its use for a purpose other than that specified in this manual The manufacturer reserves the right to make changes to the device and this manual in order t
14. duct is guaranteed for 2 YEARS as from the date of purchase The distributor reserves the right to repair or replace any parts affected by manufacturing flaws or materials used at no expense to the customer The warranty shall not apply in the event of damages caused by improper use abuse alterations or dismantling by unauthorised persons For repair in compliance with the above conditions for warranty application please send the product together with the purchase receipt to the nearest local retailer MORETT LOGIKO WARRANTY CERTIFICATE Product Purchased on date Retailer Address Town city Sold to Address Town city ed Honsun Nantong Co Ltd No 8 Tongxing Rd Nantong Economic amp Technological Dev area 226009 Jiangsu Province China Shanghai International Holding Corp GmbH Eiffestrasse 80 20537 Hamburg Germany EC RI m P Distribuito da Distributed by MORETTI S P A Via Bruxelles 3 Meleto 52022 Cavriglia Arezzo Tel 39 055 96 2111 www morettispa com email info morettispa com MADE in P R C MA DM344 349 361 362 366 367 370 02 A eng ita indd 13 e 04 05 12 10 18 14 Note MA DM344 349 361 362 366 367 370 02 A eng ita indd 14 e 04 05 12 10 18 Note MA DM344 349 361 362 366 367 370 02 A eng ita indd 15 e 04
15. e La garanzia non applicabile in caso di danni legati ad un uso improprio ad abusi ad alterazioni o ad uno smontaggio effettuato da personale non autorizzato Per riparazioni nel rispetto delle suddette condizioni per l esercizio della garanzia inviare il prodotto munito della ricevuta di acquisto al rivenditore locale pi vicino SAMORETTI LOGIKO CERTIFICATO DI GARANZIA Prodotto Acquistato in data Rivenditore Via Localit Venduto a Via Localit Honsun Nantong Co Ltd No 8 Tongxing Rd Nantong Economic amp Technological Dev area 226009 Jiangsu Province China Ec REP Shanghai International Holding Corp GmbH Eiffestrasse 80 20537 Hamburg Germany Distribuito da Distributed by MORETTI S P A Via Bruxelles 3 Meleto 52022 Cavriglia Arezzo Tel 39 055 96 2111 www morettispa com email info morettispa com MADE in P R C MA DM344 349 361 362 366 367 370 02 A eng ita indd 7 e 04 05 12 10 18 i r e 8 ENGLISH Class Medical Device with measuring function Italian Legislative Decree no 46 dated 24 02 97 implementing Directive EEC 93 42 and subsequent amendments CODES Palm aneroid sphygmomanometer kit with 3 cuffs Standard double tube palm aneroid sphygmomanometer Wall aneroid sphygmomanometer with basket Wall aneroid sphygmomanometer with tank Stand type aneroid sphygmomanometer with basket Stand type aneroid sphygmomanometer with tank
16. ial pressure is defined as DIASTOLIC pressure WHAT IS NORMAL BLOOD PRESSURE Blood pressure can vary greatly because it depends on a great many factors Generally speaking blood pressure is lower in the summer and higher in the winter Blood pressure can vary with atmospheric pressure and is significantly affected for example by physical demands emotions stress meals medicines alcohol smoke age etc It is a good idea to write down daily measurements and then consult a doctor in order to suitably define a normal blood pressure for your own body Blood pressure varies with age you will therefore need to consult a doctor to find out what blood pressure is normal for you Under no circumstances should you alter the dosage of any drugs your doctor may have prescribed REGULATIONS AND DIRECTIVES OF REFERENCE The LOGIKO sphygmomanometers by Moretti are built in compliance with current standard EN 1060 1 2 EN 1060 1 Non invasive sphygmomanometers general requirements EN 1060 2 Non invasive sphygmomanometers supplementary requirements for mechanical sphygmomanometers WARNINGS FOR USE Please read carefully this manual to ensure correct use of the device Always follow the instructions given with regard to the product you have purchased Always keep the device out of the reach of children Never take pressure above 300 mmHg MA DM344 349 361 362 366 367 370 02 A eng ita indd 8 e 04 05 12 10 18 ENGLISH 9 GENERAL ASSEM
17. lla pressione SFIGMOMANOMETRO ANEROIDE PALMARE A 1 TUBO Collegare il tubo della camera d aria al relativo attacco sullo sfigmomanometro aneroide palmare SFIGMOMANOMETRO ANEROIDE PALMARE A 2 TUBI Collegare un tubo della camera d aria ad uno dei due attacchi presenti sullo sfigmomanometro palmare Collegare l altro tubo al restante attacco presente sullo sfig momanometro N B Per l assemblaggio dello sfigmomanometro su stativo e da muro consultare le relative istruzioni aggiunte al presente manuale Gli sfigmomanometri della linea LOGIKO di serie sono dotati di bracciale standard per adulti circonferenza arto da 26 a 36 cm A richiesta sono disponibili anche i seguenti bracciali Bracciale per bambini circonferenza arto da 18 a 26 cm Bracciale per obesi circonferenza arto da 36 a 46 cm Lo sfigmomanometro aneroide palmare DM344 viene sempre fornito in kit con i 3 tipi di bracciali compresi bambini adulti e obesi Prima di procedere con l utilizzo dello sfigmomanometro bisogna scegliere il tipo di bracciale adeguato in modo da garantire una migliore precisione nella misurazione della pressione Si prega di contattare il rivenditore in caso di dubbi sulla scelta del bracciale pi idoneo MODALIT D USO L utente si dovrebbe trovare in un ambiente caldo capi di vestiario dovrebbero essere rimossi dal braccio sini stro Sedersi ad un tavolo o una scrivania dove si pu facilmente distendere il braccio Posizionare il go
18. ly the same height as your e heart Turn your arm so that the palm of your hand faces upwards Wrap the cuff around your bare arm ensuring that the centre of the cuff corresponds to the brachial artery The lower end of the cuff must be approximately 2 3 cm above the elbow joint Tighten the cuff so that it adheres closely to your arm You must be able to insert a finger between the cuff and your arm x ONES AA N B Do not tighten too far or the blood flow will be reduced significantly Insert the phonendoscope head OPTIONAL beneath the centre of the cuff approximately 3 4 cm away from the elbow joint N B The phonendoscope should not be pressed too firmly against the cuff or the diastolic pressure measured will be a false reading Wear the phonendoscope earpiece in order to hear the heartbeat Now inflate the air chamber of the cuff using the pump supplied To do so first ensure that you have closed the pressure bleed valve Pump air into the circuit until pressure reaches approximately 3B0 mmHG above normal systolic pressure if this is the first time you measure your blood pressure inflate up to approximately 180 mmHg Remain very still whilst measuring pressure Start to deflate the air chamber slowly adjusting the bleed valve in order to obtain a constant loss of pressure of approximately 2 3 mmHG per second Listen to the phonendoscope as you watch the manometer When you can clearly perceive at least two consecutive heartbeats
19. mito sul tavolo in modo che si trovi all incirca alla stessa altezza del cuore Posizionare il palmo della mano rivolto verso l alto Avvolgere il bracciale intorno al braccio nudo in modo che il centro del bracciale corrisponda all arteria brachiale La parte inferiore del bracciale deve trovarsi a circa 2 3 cm di distanza sopra la piega del gomito Strin gere il bracciale in modo da renderlo aderente al braccio Si deve poter inserire ancora un dito fra il bracciale e il braccio QC NT N B Non stringere eccessivamente altrimenti si ridurr sensibilmente la circolazione del flusso sanguigno Inserire la testa del fonendoscopio OPTIONAL sotto al centro del bracciale ad una distanza dalla piegatura del gomito di circa 3 4 cm N B Il fonendoscopio non deve essere premuto troppo saldamente al bracciale altrimenti la pressione Diastolica misurata risulter falsata Indossare l archetto del fonendoscopio per ascoltare i battiti del cuore A questo punto si deve gonfiare la camera d aria del bracciale con la pompetta presente nel dispositivo Per fare questo prima assicurarsi di aver chiuso il rubinetto di sfiato della pressione Pompare quindi aria nel circuito fino a portare la pressione all incirca 30mmHg sopra alla normale pressione sistolica nel caso fosse la prima volta che vi misurate la pressione gonfiare all incir ca sul valore di 180 mmHg Rimanere ben fermi durante la fase di misurazione della pressione Iniziare a sgonfiare len
20. o improve the device characteristics without advance notice TECHNICAL CHARACTERISTICS Storage temperature from 20 C to 70 Humidity 85 max relative Operative temperature from 0 C to 46 C Measurement range from O to 300 mmHg Minimum scale 2 mmHg Measuring accuracy 3 mmHg from 18 C to 33 C 6 mmHg from 34 C to 46 C Air leakage lt 4 mmHg min SPARE PARTS ACCESSORIES Please refer to the general MORETTI catalogue for spare parts and accessories N B The table below provides information on how to correctly use the cuff MA DM344 349 361 362 366 367 370 02 A eng ita indd 10 e 04 05 12 10 18 ENGLISH 11 CUFF TYPE ARM CIRCUMFERENCE IN CM Children 18 26 Adults 26 36 Obese 36 46 ASSEMBLY INSTRUCTIONS DM366 pon Nou Insert the telescopic tube ref 7 into the wheeled stand ref 8 Connect the two parts using the screw ref 10 and seal ref 9 Tighten the screw ref 10 using the wrench supplied ref 11 Insert the manometer ref 12 into the upper rod of the telescopic tube applying pressure in a downwards direction Adjust manometer inclination using the screw and nut ref 4 and ref 5 Adjust the stand height using the adjustment ring ref 6 Connect one end of the coil tube to the plug on the back of the manometer and the other end to one of the cuff tubes Connect the other cuff tube to the bulb with the valve ASSEMBLY INSTRUCTIONS DM361
21. suo interno lavare quindi il bracciale con acqua tiepida e sapone neutro CAMERA D ARIA Lavare con acqua tiepida e sapone neutro facendo attenzione a non far entrare l acqua all in terno Nel caso in cui un d acqua fosse penetrata all interno della camera d aria lasciare asciugare bene prima dell uso disponendo i tubi rivolti in basso per facilitare la fuoriuscita dell acqua stessa FONENDOSCOPIO OPTIONAL Utilizzare esclusivamente un panno morbido inumidito e successivamente asciu gare bene Per le restanti parti utilizzare acqua tiepida con sapone neutro e asciugare bene AVVERTENZE GENERALI vietato l utilizzo del seguente prodotto per fini diversi da quanto definito nel presente manuale La MORETTI S P A declina qualsiasi responsabilit su danni provocati da un uso improprio del dispositivo o da un uso diverso da quanto indicato nel presente manuale Il produttore si riserva il diritto di apportare modifiche al dispositivo e al seguente manuale senza preavviso allo scopo di migliorarne le caratteristiche CARATTERISTICHE TECNICHE Temperatura di immagazzinaggio da 20 C a 70 C Umidit 85 max relativa Temperatura operativa da 0 C 46 Range di misurazione a 300mmHg Risoluzione di misurazione 2 mmHg Precisione di misurazione 3mmHg tra 18 C e 33 C 6mmHg tra 34 e 46 C Perdita d aria lt 4mmHg min MA DM344 349 361 362 366 367 370 02 A eng ita indd 4 e 04 05 12 10 18 I
22. tamente la camera d aria regolando la valvola di scarico in modo da ottenere una perdita costante di pressione di circa 2 3 mmHg al secondo Ascoltare il fonendoscopio e contemporaneamente guardare il manometro AI momento che si percepiscono chiari almeno due battiti consecutivi del cuore quella la pressione massima SISTOLICA mentre nel mo mento in cui gli stessi battiti cessano di essere riconoscibili si ottiene la pressio ne minima DIASTOLICA Dopo aver ottenuto anche la pressione diastolica aprire completamente la valvola di sfiato per svuotare velocemente la camera d aria dalla pressione residua Togliere quindi il fonendoscopio e rimuovere il bracciale Non mantenere gonfiato il bracciale per troppo tempo MA DM344 349 361 362 366 367 370 02 A eng ita indd 3 e 04 05 12 10 18 e 4 ITALIANO AVVERTENZE PER LA MISURAZIONE DELLA PRESSIONE SANGUIGNA Normalmente utilizzare sempre il braccio sinistro Il braccio deve essere scoperto senza indumenti sopra Evitare qualsiasi attivita prima della misurazione Rimanere a riposo dai 5 ai 10 minuti prima di misurarsi la pressione del sangue Non parlare mangiare bere o muoversi durante la fase di misurazione Non premere la testa del fonendoscopio con le dita Questo potrebbe interferire con la lettura della pressione sanguigna Fare le misurazioni della pressione sempre alle stesse ore Registrare sempre data e l ora della misurazione MANUTENZIONE
23. zione 5 Montare il manometro sulla staffa tramite la vite e il dado rif 4 e rif 5 e prima di bloccarlo regolare l inclinazione 6 Collegare una parte del tubo a spirale all attacco presente sul retro del manometro e l altra parte ad uno dei tubi del bracciale 7 Collegare l altro tubo del bracciale alla monopalla con rubinetto ISTRUZIONI DI MONTAGGIO DM367 Inserire il tubo telescopico rif 5 nella base con ruote rif 6 Collegare le due parti tramite la vite rif 8 e la guarnizione rif 7 Avvitare e stringere bene la vite rif 8 con la chiave in dotazione rif 9 Inserire il manometro rif 10 nell asta superiore del tubo telescopico facendo pressione verso il basso Regolare l inclinazione del manometro tramite la vite e dado presenti Regolare l altezza dello stativo tramite la ghiera di regolazione rif 4 Collegare una parte del tubo a spirale all attacco presente sul retro del manometro e l altra parte ad uno dei tubi del bracciale Collegare l altro tubo del bracciale alla monopalla con rubinetto NOUR WN ISTRUZIONI DI MONTAGGIO DM362 1 Determinare un punto di fissaggio ad esempio una parete sufficientemente resistente e sicura per il montaggio del manometro Stabilire l altezza di montaggio del manometro in modo tale da non determinare pericolo e o ostacolo a persone e cose Smontare la staffa posteriore dal cestello rif 2 agendo sulla vite interna Praticare due fori nel muro adeguati per i tasseli in dotazione