1. Connect each two capacitors in SERIES then connect the two series in PARALLEL as shown in the following pictures Following table shows capacitor kit codes and capacitor technical characteristics for each model The diagrams show the connection requirements for each compressor type NOTE UL certification is available only for a limited models of H1 range For a complete list kindly contact our technical department ALIMENTAZIONE A 50 E 60 Hz SUPPLY VOLTAGE 50 AND 60 Hz EINSPEISUNG 50 UND 60 Hz VERDICHTER EINPHASIG DER H1 SERIE Die einphasigen Verdichter ben tigen ein Kondensatoren Set und ein Relais um richtig funktionieren zu k nnen Je nach ausgew hltem Modell und auf Grund der elektrischen Motorleistung werden 1 oder 2 oder 4 Anlaufverdichter notwendig sein Wenn zwei Anlaufverdichter verwendet werden so m ssen diese hintereinander geschaltet werden wie in den nachfolgenden Abbildungen dargestellt Wenn vier Anlaufverdichter gebraucht werden so m ssen diese paarweise hintereinander geschaltet sein Die zwei Reihen werden parallel geschaltet wie in den nachfolgenden Abbildungen dargestellt In den untenstehenden Tabellen sind die Kode Nummern der einphasigen Sets angegeben sowie die technischen Eigenschaften der Kondensatoren f r jeden einzelnen Verdichter ANMERKUNG Die UL Zulassung steht nur einer beschr nkten Anzahl von Modellen der H1 Serie zur Verf gung Setzen Sie sich mit unserem technischen
2. Rispetto all avviamento Y A possibile collegare in sequenza il primo avvolgimento e X successivamente il secondo senza nessuna interruzione nella erogazione della corrente evitando cosi un secondo picco di spunto Inoltre possibile utilizzare due contattori di taglia pi piccola con un consistente risparmio dei costi di installazione elettrica e dello spazio necessario nel quadro motori PWS possono essere collegati anche in modalit DOL direct on line Con questo tipo di collegamento i due avvolgimenti possono essere ponticellati insieme ed avviati contemporaneamente Le correnti di spunto del motore elettrico collegato DOL sono simili a quelle assorbite dal motore tradizionale Caratteristiche speciali dei motori Dorin Officine Mario Dorin ha sviluppato una lunga esperienza nell uso dei motori PWS che hanno dimostrato bassi carichi allo spunto alta efficienza ed eccellente affidabilit ll dimensionamento generoso del volume del motore e delle sezioni del rotore e dello statore assicurano Bassi carichi specifici Alta coppia di spunto Alta efficienza Alto fattore di potenze e Ampio range di applicazione con una grande riserva di potenza La partizione al 50 degli avvolgimenti garantisce Carichi uguali agli avvolgimenti Campi magnetici bilanciati motori PWS sono equipaggiati con 6 sonde PTC che assicurazione una ampia protezione contro Sovraccarico Raffreddamento insufficiente Dan
3. oder mit Teilwicklungsanlauf PWS auf Anfrage zur Verf gung Die folgende Tabelle zeigt die jeweils verf gbare Motortype ANMERKUNG Die UL Zulassung steht nur einer beschr nkten Anzahl von Modellen zur Verf gung Setzen Sie sich COLLEGAMENTO CONNECTION VERBINDUNG PWS or DOL mit unserem technischen Service in Verbindung um die genaue Liste zu erfragen ANSCHLUSS MIT TEILWICKLUNGSANLAUF PWS ANSCHLUSS Elektromotoren ben tigen einen starken Anlaufstrom wenn sie an einem direkten Anschluss gestartet werden Der Anlaufstrom kann auch acht Mal st rker als der Nennstrom sein Bei gr eren Motoren ist es blich angemessene technische Vorkehrungen zu treffen um den Anlaufstrom und die Belastung der elektrischen Leitungen zu reduzieren In den letzten Jahren hat das System des Teilwicklungsanlaufs in Kombination mit Vorkehrungen zum Leerstart das zuvor angewandte Stern Dreieck Anlaufsystem ersetzt Die Vorteile sind hohe Effizienz bei der Begrenzung des Einschaltstroms bis max 65 des Anlaufstromes Niedrige Kosten f r die Kontaktoren costruzione Nei motori PWS l avvolgimento statorico separato in due parti normalmente Y YY o A A connection isolate l una dall altra Le due parti sono poste nelle cave dello statore nella corona degli avvolgimenti In questa configurazione possibile azionare gli avvolgimenti uno alla volta ottenendo una consistente riduzione della corrente di spunto
4. service in Verbindung um die genaue Liste zu erfragen Starting capacitor Running capacitor Verdichter Anlauf Kondensatoren Betriebskondensatoren Compressore Condensatori di avvio Condensatori di marcia m H40CC H75CS H100CC H100CS H150CC H150CS H180CC H200CS H250CC H280CC Lp m9 poe pomme 3 oes oem Te oem o oem COMPRESSORI UL 60 Hz UL COMPRESSORS 60 Hz UL VERDICHTER 60 Hz Starting capacitor Running capacitor Verdichter Anlauf Kondensatoren Betriebskondensatoren Compressore Condensatori di avvio Condensatori di marcia d 9 e Ja 1RC8211 1RC8191 1RC8231 SCHEMA COLLEGAMENTO ELETTRICO ELECTRICAL CONNECTION ELEKTRISCHES VERBINDUNGSSCHEMA NERO BLACK RIGIO GREY GRIGIO GREY Schema di collegamento elettrico con 4 condensatori di spunto Schema di collegamento elettrico con 1 o 2 condensatori di spunto d Electrical connection scheme with 4 start capacitors Electrical connection scheme with 1 or 2 start capacitors Schema der elektrischen Anschl sse mit 4 Anlauf Verdichtern Schema der elektrischen Anschl sse mit 1 oder 2 Anlauf Verdichtern SC1 SC2 SC3 SC4 start E marrone brown brown anlaut Kondensator Kondensator mn run pu nero black black Betrebstondensator Schwarz uum Q COMPRESSORI SERIE H1 TRIFASE E SCC_1 La seguente tabella illustra le tipologie di motore disponibili sui compressori della gamma H1 NB Pomologazione UL disponibile per un numero di modelli
5. 44 EFF ase en H551CC H801CC 38 06 KEE 2657 H851CS GENERALITA II presente bollettino tecnico descrive i collegamenti elettrici previsti per i compressori prodotti da Officine Mario Dorin sulle seguenti gamme di compressori Serie H Serie HI Serie HEX Serie SCC Serie CD E sulle seguenti unit condensatrici su cui sono installati i compressori semiermetici della serie H Serie AU Serie AUT Serie AULN Serie AUI Serie WU Serie RU l corretto collegamento elettrico in funzione della tipologia di motore installato sul compressore e della tensione di rete 8 condizione imprescindibile per il corretto funzionamento del compressore L errato collegamento elettrico pud portare a cortocircuiti e quindi causare la bruciatura del motore elettrico Installando il compressore in condizioni difformi rispetto a quelle indicate in questo Bollettino Tecnico si potranno avere condizioni di lavoro non contemplate nella fase di progetto II compressore pertanto non garantir le prestazioni dichiarate e potrebbe andare incontro a a serio danneggiamento Nel presente Bollettino Tecnico saranno riportati per i vari modelli e gamme gli schemi elettrici di collegamento Per informazioni relative a compressori speciali contattare il nostro servizio tecnico commerciale attenzione Si raccomanda di eseguire i collegamenti elettrici in accordo con gli schemi allegati al presente Bollettino Tecnico e nel rispetto de
6. Gh DORIN Innovation EENN EN BOLLETTINO TECNICO TECHNICAL BULLETIN TECHNISCHE MITTEILUNGEN BI 008 CONNESSIONI ELETTRICHE ELECTRICAL CONNECTION ELEKTRISCHE ANSCHL SSE Indice Table of contents Inhaltsverzeichnis Sommario Summary Inhaltsangabe pag 3 Generalit Generality Allgemeines pag 3 Compressori serie H1 monofase H1 range single phase Verdichter der H1 Serie_einphasig pag 4 compressori serie H1 trifase e SCC H1 and SCC 1 range three phases Verdichter der H1 Serie dreiphasig und scc_1 pag 6 compressori serie H2 H32 H34 H54 e SCC_ 32 H2 H32 H34 H35 and SCC 32 compressor ranges Verdichter der Serien h2 h32 h34 h35 und scc_32 pag 7 collegamento PWS PWS connection PWS Anschluss pag 7 compressori serie H4 H41 H5 H6 H7 e SCC_4 CD H4 H41 H5 H6 H7 and SCC4 CD compressor range Verdichter der Serien H4 H41 H5 H6 H7 und SCC_4 CD pag 12 Modalit di collegamento Connection mode Anschlussart pag 13 Sommario IL presente bollettino tecnico descrive la tipologia dei motori elettrici e le istruzioni di collegamento elettrico per le seguenti gamme di compressori prodotti da Officine Mario Dorin e su tutte le unit condensatrici dove sono installati i compressori riportati in tabella Summary Subject of the present bulletin are electrical motor characteristics and electrical connection of following compressor ranges produced by Officine Mario Dorin and condensing units related to
7. die zwei Wicklungen untereinander verbunden und gleichzeitig gestartet werden Der Anlaufstrom des im DOL Modus verbundenen Elektromotors hnelt der aufgenommenen Leistung eines herk mmlichen Motors Besondere Eigenschaften der Dorin Motoren Officine Mario Dorin weist eine betr chtliche Erfahrung in der Anwendung von Motoren mit Teilwicklungsanlauf auf die sich f r einen niedrigen Anlaufstrom hohe Leistungsf higkeit und ausgezeichnete Zuverl ssigkeit auszeichnen Die gro z gigen Abmessungen des Motorvolumens sowie der Rotor und Statorabschnitte gew hrleisten geringe spezifische Belastung Hohes Anlaufdrehmoment Gro e Effizienz Hoher Leistungsfaktor Dimensionamento contattori In caso di collegamento DOL direct on line deve essere selezionato un singolo contattore l dimensionamento va effettuato sulla base della massima corrente di funzionamento del compressore FLA Il valore della massima corrente di funzionamento amp riportato sulla targhetta del compressore In caso di collegamento PWS ogni contattare deve essere selezionato per sopportare del valore della FLA massima corrente di funzionamento del compressore Connessioni elettriche Collegare le fasi ed i ponticelli esattamente come indicato nello schema di seguito attenzione Una connessione non corretta pu creare campi magnetici rotanti in direzioni opposte creando una situazione simile a quella di rotore bloccato Col
8. each model Inhaltsangabe Die vorliegende beschreibt die schildert die elektrischen technische Anleitung Elektromotortype und Anweisungen f r den Anschluss der folgenden Auswahl an Verdichtern die von Officine Mario Dorin hergestellt werden sowie die entsprechenden jeweils Verfluessigungssaetze aer Dap HISO1CO DEE H200100 HIGDICS H220100 AAA A AAA TI ka A Serie Modello Mendes A Serie Modello b A Modello pieni Serie Modello nn Range Model Range Model Model Range Model Serie Mod le Volume bal Sarie Mod le Volume bal Mod le ESSEE ia Serie Mod le Volume bal Serie Typ F rdervolumen Serie Typ F rdervolumen Typ Serie Typ F rdervolumen m h el oe 20 H2000CS E Hsocs 386 H2500CC ucc 39 Ho500cs 850 H75CS H3000CC 85 01 ower 9225 CD 200 Hos0cs 10235 Wsaxcc 10235 co 36om H180CC 7 71 SCC1500B 500B a 0020008 SCC2500B 48 8 D 3808 H220CC 9 88 H4000C C 127 52 Hasoocs 158 52 CD 300 PHs000cc 15852 SLING pa LEES mm 6 92 pS CHE Hssoocc 16430 cbi200H Ise coso 892 CD 1100M 8 92 H350CC epus H350SB PUMP H380CC co 10008 us co 1aoom 1162 H403CC 19 98 Haoscs Ss soc 2289 CD 400 mec 264 ENG raso 26
9. egamento elettrico PWS DIRETTA gamme H4 H5 H6 H7 e SCC_4 CD PWS DOL electrical connection scheme H4 H5 H6 H7 and SCC_4 CD Schema der PWS DIREKTEN elektrischen Anschl sse der Serien DIRETTA ground connection Erdanschlu T1 T2 L1 L2 L3 13 MODALITA DI COLLEGAMENTO Aprire il coperchio della scatola attacchi elettrici e Realizzare i collegamenti come riportato sull adesivo all interno della scatola attacchi elettrici oppure in accordo a quanto contenuto in questo Bollettino Tecnico Utilizzare pressacavi idonei al fine di garantire il grado di protezione originale della scatola stessa Collegare la rete elettrica alla morsettiera utilizzando idoneo cavo elettrico isolato Serrare perfettamente i collegamenti elettrici nella posizione scelta Richiudere il coperchio della scatola terminali Attenzione Non avviare il compressore con la scatola attacchi elettrici aperta Istruzioni per il collegamento dei ponticelli Per un corretto collegamento dei ponticelli seguire la seguente procedura serrare il dado 1 su ogni ponticello posizionare una rondella 2 su ogni dado posizionare i ponticelli 3 secondo quanto indicato nello schema attacchi elettrici del compressore posizionare il capocorda 4 come indicato nello schema attacchi elettrici gt posizionare una rondella 5 su ogni passante gt serrare il dado 6 su ogni passante Durante l operazione di serraggio del dado 6 ma
10. ertification is available only for a limited models For a complete list kindly contact our technical department H2 H32 H34 SCC ALIMENTAZIONE SUPPLY VOLTAGE SPEISUNG 380 420 50 Hz 440 480 60 Hz 220 240 50 Hz 265 290 60 Hz 380 420 220 240 200 50 Hz or 200 60 Hz 208 230 3 60 380 420 50 Hz 440 480 60 Hz 220 240 50 Hz 250 280 60 Hz 380 420 V 60 Hz 220 240 V 60 Hz non disponibile su compressori gamma H2 e SCC 32 not available on H2 compressor range Steht f r Verdichter der H2 und SCC 32 Serien nicht zur Verf gung PWS CONNECTION Big inrush current can occur when electrical motor are started direct on line The inrush starting current can be 8 time higher compared to nominal operating current With larger motor measures to reduce the starting current and the consequential increased load in the supply voltage net has found In the last years PWS system part winding system has replaced the previous Y A motor PWS advantages are high efficiency in dumping inrush current up to 65 of the looked rotor current e and low cost for contactor combination VERDICHTER DER SERIEN H2 H32 H34 H35 UND SCC 32 Die Verdichter der Serien H2 H32 H34 H35 stehen ausschlie lich mit dreiphasigen Motoren zur Verf gung Die Modelle der H2 und SCC 32 Serie stehen nur mit Stern Dreieck Motor zur Verf gung Die Verdichter der Serie H32 H34 und H35 stehen mit einer Stern Dreieck Ausf hrung Standardausf hrung
11. heizung des Kurbelgeh uses ausgestattet sein so muss diese getrennt angeschlossen werden so wie in den spezifischen technischen Informationen BT_001 angegeben COMPRESSORI SERIE H1 MONOFASE compressori monofase necessitano di un kit di condensatori e di un relay per funzionare correttamente A seconda del modello prescelto saranno necessari 1 o 2 o 4 condensatori di spunto in base alla potenza elettrica del motore Se si utilizzano due condensatori di spunto questi dovranno essere collegati in serie come mostrato nella figure sottostanti Se si utilizzano 4 condensatori di spunto questi dovranno essere montati in serie a due a due Le due serie vanno poi collegate in parallelo come illustrato nelle figure sottostanti Le tabelle sottostanti riportano i codici dei kit monofase e le caratteristiche tecniche dei condensatori per ogni compressore NB l omologazione UL amp disponibile per un numero di modelli limitato della gamma H1 Contattare il nostro servizio tecnico per la lista esatta H1 RANGE SINGLE PHASE Single phase compressors require a kit comprising of capacitors and relay in order to operate correctly Depending on the selected model there will be either one or two or four start capacitors rated for the appropriate motor size If two start capacitors are used then these must be connected in SERIES as shown on the following diagrams If four start capacitors are used then make two groups of two capacitors
12. hen Anleitung Geeignete Kabelhalter verwenden um die urspr ngliche Schutzleistung des Kastens selber zu gew hrleisten Das Stromnetz an die Klemme mit einem geeigneten und isolierten Stromkabel anschlie en Die elektrischen Verbindungen an der gew nschten Stelle perfekt anziehen Den Deckel des Anschlusskastens wieder schlie en Achtung Den Verdichter nicht bei Anschlusskasten starten offenem Anleitungen f r den Anschluss der Br cken Um die Br cken richtig anzuschlie en der nachstehenden Prozedur folgen gt Mutter 1 auf jeder Br cke anziehen gt eine Unterlegscheibe 2 auf jede Mutter geben gt Br cken 3 gem den Anleitungen des Schaltplans des Verdichters platzieren gt Kabelschuh 4 wie im Schema der elektrischen Anschl sse platzieren gt eine Unterlegscheibe 5 auf jede Verbindung geben gt Mutter 6 auf jeder Verbindung anziehen Beim Anziehen von Mutter 6 Mutter 1 mit einem zweiten Schl ssel festhalten Hinweis Die Mutter 6 nicht ohne Schl ssel anziehen um Mutter 1 in Stellung zu halten NOTE NOTE NOTE 1LTZ BT 008 12A TTL LC UI OFFICINE MARIO DORIN S p A Via Aretina 388 50061 Compiobbi Firenze Italy Tel 39 055 623211 Fax 39 055 62321380 www dorin com dorin dorin com u u u ean
13. ical Bulletin you will find all the connection diagrams covering all the compressor ranges warning It is recommended that connections be made in accordance with the diagrams enclosed in this Technical Bulletin and also in compliance with local safety regulations and standards Connections should only be made by qualified personnel Dorin will not accept any responsibility for any damage to persons property or machinery of any kind due to incorrect actions on the compressor For safety requirements the instructions for use and maintenance which are supplied with the compressor MUST always be followed during compressor installation If the compressor is fitted with a crankcase heater then this must be connected separately in accordance with the specific technical bulletin BT_001 ALLGEMEINE HINWEISE Die vorliegenden technischen Informationen beschreiben die elektrischen Anschl sse die folgenden Verdichterserien der Firma Officine Mario Dorin vorgesehen sind Serie H Serie HI Serie HEX Serie SCC Serie CD und die auf den nachfolgend aufgef hrten Verfl ssigungseinheiten vorgesehen sind auf denen halbhermetische Verdichter der Serie H installiert sind Serie AU Serie AUT Serie AULN Serie AUI Serie WU Serie RU Der korrekte elektrische Anschluss je nachdem welcher Motor auf dem Verdichter installierter ist und je nach Netzspannung ist f r ein korrektes Funktionieren des Verdichters von unabdingbarer W
14. ichtigkeit Der falsche elektrische Anschluss kann zu Kurzschl ssen f hren und demzufolge einen_Elektromotorbrand verursachen Sollte der Verdichter nicht konform gem den Angaben der vorliegenden technischen Informationen installiert werden k nnen sich Betriebsbedingungen ergeben die w hrend der Planung nicht ber cksichtigt worden sind Der Verdichter wird demzufolge nicht die erkl rten Leistungen erbringen und k nnte schwer besch digt werden In den vorliegenden technischen Informationen werden je nach Modell und Serienart die elektrischen Anschlussschemen angegeben Sollten Sie Informationen bez glich Spezial Verdichter ben tigen setzten Sie sich bitte mit unserem technischen kommerziellen Service in Verbindung Achtung Es ist ratsam die elektrischen Anschl sse gem den Schemen der vorliegenden technischen Informationen und gem den Sicherheitsvorschriften auszuf hren die am Installationsort rechtsg ltig sind Die elektrischen Anschl sse m ssen ausschlie lich durch fachkundiges Personal ausgef hrt werden die Firma Dorin wird in keinem Fall f r Sch den an Sachen oder Personen verantwortlich sein die auf unsachgem e Eingriffe auf den Verdichter zur ckzuf hren sind Hinsichtlich der Sicherheitsvorkehrungen muss w hrend der Installation des Verdichters den Bedienungs und Wartungsanleitungen gefolgt werden die zusammen mit dem Verdichter geliefert werden Sollte der Verdichter mit einer l
15. la tipologia di motore disponibile per ogni gamma NB Pomologazione UL amp disponibile per un numero di modelli limitato Contattare il nostro servizio tecnico per la lista esatta MOTORE MOTORE MOTOR STANDARD 60 Hz 200 50 60 Hz U COLLEGAMENTO PWS motori elettrici sono soggetti ad alte correnti di spunto quando vengono azionati con collegamento diretto La corrente di spunto pu essere anche 8 volte superiore alla corrente nominale Nei motori di taglia maggiori si e soliti installare soluzioni tecniche atte a ridurre le correnti di spunto ed i carichi sulla linea elettrica Negli ultimi anni il sistema PWS abbinato ai dispositivi di partenza a vuoto ha rimpiazzato il precedente azionamento stella triangolo oggi praticamente in disuso motori PWS assicurano i seguenti vantaggi Consistente riduzione della corrente di spunto le correnti di spunto vengono ridotte fino a circa il 6596 della corrente a rotore bloccato se il compressore dotato di dispositivo di partenza a vuoto e Basso costo dei contattori H2 H32 H34 H35 AND COMPRESSOR RANGE SCC 32 H2 H32 H34 H35 and SCC32 compressor range are available only with three phases motor H2 and SCC32 ranges are equipped only with star delta motor H32 H34 H35 range are equipped with star delta motor as standard supply PWS motor are available on request In the following table a list of available motors for each range is shown NOTE UL c
16. legare le fasi ed I ponticelli esattamente come indicato nello schema Ritardo chiusura contattori In caso di collegamento PWS il ritardo consigliato tra la chiusura dei due contattori 8 0 2 0 4 s attenzione Un ritardo maggiore di 0 4 s puo causare rischio di rottura del motore elettrico per sovraccarico Contactor sizing DOL connection only one contactor must be selected on the basis of the whole maximum operating current FLA of the compressor Maximum operating current is written on the compressor name plate PWS connection with connection two contactors are needed every one must withstand Ve of maximum operating current FLA Electrical connection Connect the line and the bridges as indicate in the following scheme warning Incorrect connection of terminal leads to magnetic fields rotating in opposite direction Locked rotor conditions occurs when the motor is switched on with high risk of motor failure Connect the terminal exactly as indicated in the following scheme Delay between contactors connection In case of PWS connection time delay between two contactors 0 2 0 4 s warning Concrete risk of motor failure occur if time delay is higher than 0 4 s 10 Gro er Anwendungsbereich mit gro er Leistungsreserve Die 50 Aufteilung der garantiert Gleiche Belastung der Wicklungen Ausgeglichene Magnetfelder Wicklungen Die Motoren mit Teilwicklungsanlauf sind mit sechs PTC Sonden ausgesta
17. limitato della gamma H1 Contattare il nostro servizio H1 AND SCC_1 RANGE PHASES THREE Following table shows all the motors available on the H1 compressor range NOTE UL certification is available only for a limited models of H1 range For a complete list kindly contact our technical department VERDICHTER DER H1 DREIPHASIG UND SCC 1 SERIE Die folgende Tabelle zeigt die zur Verf gung stehenden Motorentypen der Verdichter der H1 Serie ANMERKUNG Die UL Zulassung steht nur einer beschr nkten Anzahl von Modellen der H1 Serie zur Verf gung Setzen Sie sich mit unserem technischen Service in Verbindung um die genaue Liste zu erfragen MOTORE ALIMENTAZIONE COLLEGAMENTO MOTORE SUPPLY VOLTAGE CONNECTION MOTOR EINSPEISUNG VERBINDUNG STANDARD 60 Hz mae CR tecnico per la lista esatta Schema di collegamento elettrico stella triangolo gamme H1 SCC 1 Star delata electrical connection scheme H1 SCC 1 Schema der elektrischen Stern Dreieck Anschl sse f r die Serien H1 SCC 1 ErdanschluB Verbindungen Durchf hrungen U1 V1 W1 U2 V2 W2 COMPRESSORI SERIE H2 H32 H34 H35 E SCC 32 compressori delle gamme H2 H32 H34 H35 sono disponibili esclusivamente con motore trifase I modelli della gamma H2 e SCC_32 sono disponibili solo con motore stella triangolo compressori della gamma H32 H34 e H35 sono disponibili nella versione stella triangolo standard o PWS su richiesta La seguente tabella mostra
18. lle norme di sicurezza in vigore nel luogo di installazione collegamenti elettrici devono essere eseguiti esclusivamente da personale specializzato Dorin non sar responsabile per alcun motivo di danni a cose o persone derivanti da azioni scorrette effettuate sul compressore Per i requisiti di sicurezza si deve tenere presente in fase di installazione del compressore quanto contenuto e riportato nelle istruzioni d uso e manutenzione fornite a corredo il compressore Se il compressore corredato di resistenza carter questa deve essere collegata separatamente in accordo con quanto indicato nello specifico bollettino tecnico BT 001 GENERALITY Present bulletin describes the electrical connection suitable for the following compressor ranges produced by Officine Mario Dorin H range HI range HEX range SCC range CD range And on condensing units where semihermetic compressors belonging to H range are installed AU range AUT range AULN range AUI range WU range RU range For a proper operation electrical machines has to be correctly connected to the main voltage supply depending on both electrical motor and supply voltage at the net An incorrect connection can cause a short circuit and hence a motor burn out Any connection that is NOT made in accordance with the following recommendations will not guarantee correct functioning of the compressor nor performance data declared in the catalogue In this Techn
19. neggiamento delle fasi construction In PWS motors the stator winding is separated in two parts normally Y YY or A connection insulated from each other They lay in the stator slots at the winding crown With this system it is possible to switch the windings one by one with a small time delay obtaining a consistent reduction in the starting current Comparing with Y A system in PWS motor it is possible to switch from one energized winding to the other one without any interruption in the voltage supply eliminating a second current peak Furthermore two smaller contactors are required reducing the installation cost and the space in the electrical installation PWS motor can also be connected in DOL direct on line mode With DOL connection both motor winding are connected together at the electrical plate pins With this connection inrush current at the motor start up are similar to traditional one Special feature of Dorin motors Officine Mario Dorin has developed a big experience in the use of PWS motor resulted in low supply load high efficiency and reliability The generous motor volume and the stator and rotor section can ensure Low specific load High torque at the start up High efficiency High power factor Wide application range with a large power reserve 5096 winding partition can ensure Equal winding loads Balanced magnetic field PWS are equipped with 6 PTC sensor which ensure a c
20. nnection scheme H32 H34 H35_SCC32 Schema der elektrischen Stern Dreieck Anschl sse f r die Serien H32 H34 H35 SCC_32 collegamento a stella star connection Stern Anschluss collegamento a triangolo delta connection Dreieck Anschluss collegamento a terra ground connection thermal protection Thermoschutzeinrichtung U1 V1 W1 Verbindungen Durchf hrung 11 SCHEMA DI COLLEGAMENTO CONNECTION SCHEME SCHEMA ELEKTRISCHEN ANSCHLUSSE Schema di collegamento elettrico PWS DIRETTA gamme H32 H34 H35 PWS DOL electrical connection scheme H32 H34 H35_SCC32 Schema der PWS DIREKTEN elektrischen Anschl sse f r die Serien H32 H34 H35 9 m Me 12 COMPRESSORI SERIE H4 H41 H5 H6 H7 E GAMME SCC 4 CD H4 H5 H6 H7 AND SCC 4 AND CD COMPRESSOR RANGE compressori della serie H4 H5 H6 H7 e H4 H5 H6 H7 e CD CD sono disponibili esclusivamente con motore trifase PWS La seguente tabella mostra i disponibili compressori per queste gam Following table shows range are equipped only with PWS three phases motor available motor type motori for these compressor ranges me di H4 H5 H6 H7 CD VERDICHTER DER SERIEN H4 H41 H5 H6 H7 UND SCC 4 CD Die Verdichter der Serien H4 H5 H6 H7 stehen ausschlie lich mit dreiphasigen Motoren mit Teilwicklungsanlauf zur Verf gung Die folgende Tabelle zeigt die f r diese Verdichter Palette zur Verf gung stehenden Motoren PWS or DOL Schema di coll
21. ntenere fermo il dado 1 con una seconda chiave Nota non serrare il dado 6 senza l ausilio della chiave per mantenere il dado 1 in posizione CONNECTION MODE Open the terminal box cover Arrange the connection tabs in accordance with the adhesive diagram inside the box or in accordance with this Technical Bulletin Use appropriate cable glands to ensure the integrity of the box to original standard Connect the wires to the terminals using appropriate insulated cable e Ensure that the terminals are tightly fastened in the selected position Re fit the terminal box cover Warning Do not start compressor with the electrical box open Electrical bridges installation For a correct installation of the electrical bridges on the pins follow the procedure gt tighten the nut 1 on every pin gt put a washer 2 on every nut gt put the bridges on the pins in accordance to the selected scheme gt put the cable on the selected pins in accordance to the electrical scheme gt put a washer 5 on every pin gt tighten the nut 6 on every pin During tightening the net 6 hold the nut 1on position using an other wrench Note do not tighten the nut 6 without using the other wrench on the nut ANSCHLUSSART Den Deckel des Elektroschaltkastens ffnen Den Anleitungen folgen die auf dem Etikett beschrieben sind dass sich im Schaltkasten selber befindet oder folgen Sie den Angaben der vorliegenden technisc
22. omplete protection of both winding against Overloading Insufficient cooling Phase failure ersetzt das heute praktisch au er Gebrauch gekommen ist Motore mit Teilwicklungsanlauf bieten folgende Vorteile Bedeutende Reduzierung des Anlaufstroms der Anlaufstrom wird auf ung 65 des Stromes bei blockiertem Rotor reduziert wenn der Verdichter mit einer Vorkehrung zur Anlaufentlastung ausgestattet ist Kosteng nstige Installationssch tze Aufbau In Motoren mit Teilwicklungsanlauf besteht die Statorwicklung aus zwei Teilen normalerweise eine Y YY oder eine A AA Verbindung die voneinander isoliert sind Die zwei Drehstromwicklungen befinden sich in der Wicklungskrone der Statorkammer Dank dieser Ausf hrung ist es m glich die Wicklungen nacheinander zu starten wodurch eine erhebliche Reduzierung des Anlaufstromes erzielt wird Im Vergleich zum Y A Anlauf ist es m glich die erste Wicklung und darauf folgend die zweite Wicklung ohne jegliche Unterbrechung der Stromzufuhr anzuschlie en Dadurch wird eine zweite Stromspitze beim Anlaufen vermieden Au erdem ist es m glich zwei kleinere Installationssch tze Kontaktgeber zu montieren mit einer sich daraus ergebenden bedeutenden Ersparnis der elektrischen Installationskosten und des ben tigten Raumes im Schaltkasten Die Motoren mit Teilwicklungsanlauf k nnen auch im DOL Modus direct on line angeschlossen werden Mit dieser Verbindungsart k nnen
23. ttet die einen sicheren Schutz bieten gegen berlastung unzureichende Abk hlung Phasenbesch digung Dimensionierung der Installationssch tze Kontaktgeber Bei einem DOL direct on line Anschluss muss ein einzelner Kontaktgeber gew hlt werden Die Dimensionierung erfolgt anhand der maximalen Leistungsaufnahme des Betriebsstromes des Verdichters FLA Der Wert des maximalen Betriebsstromes ist auf dem Schild des Verdichters angegeben Beim Anschluss eines Motors mit Teilwicklungsanlauf muss jeder Kontaktgeber 1 2 des FLA Wertes aushalten k nnen maximaler Betriebsstrom des Verdichters Elektrische Verbindungen Die Phasen und die Br cken genauso wie im folgenden Schema angegeben montieren Achtung Ein nicht richtiger Anschluss kann zu Magnetfeldern f hren die in entgegengesetzter Richtung drehen was zu einem hnlichen Zustand wie bei einem blockierten Rotor f hrt Die Phasen und die Br cken genauso wie im Schema angegeben montieren Versp tetes Abschlie en der Kontaktgeber Bei Anschluss mit Teilwicklungsanlauf betr gt die empfohlene Verz gerung der zwei Kontaktgeber 0 2 0 4 Sekunden Achtung Eine Verz gerung die mehr als 0 4 Sekunden betr gt kann einen Motorschaden wegen berbelastung verursachen SCHEMA DI COLLEGAMENTO CONNECTION SCHEME SCHEMA ELEKTRISCHEN ANSCHLUSSE Schema di collegamento elettrico stella triangolo gamme H32 H34 H35 SCC_32 Star delta electrical co

Download Pdf Manuals

image

Related Search

Related Contents

02 特記仕様書 (PDFファイル 480.0KB)  Manuel d`utilisation et d`entretien INJECTEUSE A CREME  Samsung DIGIMAX A6 User Manual  PERISIAN PCB (PCB SOFTWARE) USER MANUAL  RW180 User Guide V1.2  NL, NM  Avira Management Console  Prime-Line H 3966 Instructions / Assembly  T H E R M O P T I M ® VAPOR CHARTS  Dell PowerEdge T410 Owner's Manual  