Home

DTAA0009 Rev.01 Istruzioni d`uso centraline serie MC, MS, CP

image

Contents

1. 8 cc rev Pressure max 90 bar for pumps with displacement 9 8 cc rev Temperature max 80 with sheet tank max 70 with PE tank max 60 with PP tank for vertical m ounting max 50 with PP tank for horizontal mounting Minimum pressure at drain for operation of the descend control valve 10 40 bar depending on the type of valve Voltage that can be applied to the solenoid valve 10 5 of nominal value Hydraulic fluid viscosity 12 80 cSt min max Environmental limits Temperature 15 40 min max The power pack with plastic tank PP PE must be applied in environments protected against exposure to the sun s rays and with limited heat differences Conformity to the Directives of the power pack serie MC MS CP Machinery Directive 98 37 EC Assembled Power Pack Declaration of the Manufacturer enclosure II B The Power Pack is built to be incorporated in a machine using our istructions and it can be commissioned only when the conformity to the 98 37 EC Machinery Directive of the machine it is incorpored in has been declared Directive EMC 89 336 EEC AC Motor Three phase and Single phase Conforming to Directive DC Motor wound fields Conforming to Directive DC Motor permanent magnets Not Conforming Directive BT 2006 95 EC AC Motor Three phase and Single phase Conforming to Directive DC Motor Excluded from Directive until 75 V Directive PED 27 23 EC Assembled Power Pack Excluded from Directi
2. quale il gruppo leva deve essere montato grasso per guarnizioni introdurre il gruppo leva fino al contatto fra camma e perno orientare secondo esigenze e fissare con le due viti 4Nm In caso di avaria difficolt di funzionamento perdita olio ecc smontare il gruppo leva a macchina ferma e pressione zero nell impianto idraulico Ogni intervento sulla centralina deve essere eseguito a macchina ferma e pressione zero nell impianto idraulico LIMITI Funzionamento Portata max 20 l min Portata ottimale 3 15 l min Pressione minima 10 bar Pressione max 250 bar per pompe Gruppo 05 Pressione max 290 bar per pompe 1 2 4 3 cc Pressione max 260 bar per pompe 4 8 cc Pressione max 210 bar per pompe 6 0 cc Pressione max 160 bar per pompe 7 8 cc Pressione max 90 bar per pompe 9 8 cc Temperatura max 80 Ccon serbatoio in lamiera max 70 con serbatoio in plastica PE max 60 Ccon serbatoio in plastica PP per montaggio verticale max 50 Ccon serbatoio in plastica PP per montaggio orizzontale Minima pressione allo scarico per il funzionamento della valvola controllo discesa 10 40 bar secondo il tipo di valvola Tensione applicabile all elettrovalvola 10 5 del valore nominale Viscosit fluido idraulico 12 80 cSt min max Limiti ambientali Temperatura 15 40 min max La centralina con serbatoio in plastica PP PE deve essere applicata in ambienti protetti da esposizione ai raggi sol
3. EhuUdr app Hydr app S p A Via Moscova 6 Villaggio Crostolo 42020 Reggio Emilia Italy Tel 39 0522 270711 Fax 39 0522 270660 E mail salesdept hydr app com Istruzioni d uso centraline serie MC MS CP USO PREVISTO La centralina serie MC MS CP destinata ad automazione oleodinamica come organo di comando Operazioni di assemblaggio installazione manutenzione ed avviamento __ delle centraline devono essere effettuate da personale tecnico competente USO IMPROPRIO La centralina non deve essere utilizzata in ambienti a rischio di incendio o esplosione impianti e veicoli aerei e spaziali sistemi di guida di veicoli di trasporto di persone animali e cose sistemi di frenatura arresto e sosta impianti e attrezzature militari medicali e ospedalieri La centralina non assolve la funzione di sicurezza IMMAGAZZINAMENTO Riporre in luogo protetto a temperatura ambiente 10 30 max 40 per brevi periodi e al riparo da fonti di calore e da fonti luminose INSTALLAZIONE Fissare sulla macchina in punti solidi evitare punti esposti ad urti evitare punti esposti alla luce solare e punti che possano trasmettere vibrazioni verificare la pulizia dell impianto utilizzare olio nuovo e filtrato utilizzare raccordi con filettature cilindriche e guarnizioni di tenuta in rame AVVIAMENTO Scollegare la linea di pressione dal cilindro e riporla all interno di un contenitore pulito Av
4. ari e con limitate escursioni termiche Conformit alle Direttive della centralina serie MC MS CP Direttiva Macchine 98 37 CE Centralina assemblata Dichiarazione del Fabbricante allegato Il B La centralina costruita per essere incorporata in una macchina secondo le nostre istruzioni e pu essere messa in servizio solo quando la macchina in cui incorporata stata dichiarata conforme alle disposizioni della Direttiva Macchine 98 37 CE Direttiva EMC 89 336 CEE Motore AC Trifase e Monofase Conforme alla Direttiva Motore DC Campi avvolti Conforme alla Direttiva Motore DC Magneti permanenti Non Conforme Direttiva BT 2006 95 CE Motore AC Trifase e Monofase Conforme alle Direttive Motore DC Escluso dalla Direttiva fino a 75 V Direttiva PED 27 23 CE Centralina assemblata Esclusa dalla Direttiva Direttiva ATEX 94 9 CE Centralina assemblata Non Conforme La centralina non deve essere utilizzata in ambiente con atmosfera esplosiva DTAA0009 Rev 01 Instructions for use power packs series MC MS CP INTENDED USE The MC MS CP series of power packs is destined for hydraulic automation as control element Mounting installing servicing and starting the power packs must be carried out by skilled technicians IMPROPER USE The power pack must not be used in environments where there is the risk of fire or explosion aviation and space vehicles and systems steering systems of veh
5. icles for transporting people animals and things braking stopping and parking systems military medical and hospital equipment and systems The power pack does not have a safety function STORAGE Keep in protected place at room temperature 10 30 C max 40 for short periods and protected against heat and light sources INSTALLATION Fix to the machine in solid points avoid points subject to knocks points exposed to sunlight and points that could transmit vibrations verify system cleanliness use new filtered oil use fitting with cylindrical threads and copper gaskets STARTING Disconnect the pressure line from the cylinder and place it in a clean box Start and stop the power pack motor with 1 second ON OFF cycles continue until oil comes out of the pressure line Reconnect the pressure line to the cylinder and top the tank up Run several complete strokes of the cylinder to bleed the circuit and then check the level of the oil again Check the maximum pressure valve setting IMPORTANT INFORMATION AND INSTRUCTIONS Hydraulic fluid mineral base ISO 6743 4 viscosity ISO 3448 working viscosity 20 50 cSt working temperature 30 60 Mounting the tank check that the tank is clean make sure the seal is in good conditions mount the tank greasing the seal and the opening of the tank with grease for seals fix the tank Mounting the coupling on the A C motor standardised motor See the technical catalogue
6. s or consult the Hydr app SpA technical staff Electrical connection for the D C motor Tightening torques recommended for the motor poles ISO M8 5 7 Nm Tightening torques recommended for the remote control switch poles ISO M6 3 5 Nm Prior to starting we suggest running a few settling cycles for the remote control switch with medium low loads Rotation direction Looking at the power pack from the motor side clockwise direction Mounting the manual control lever unit The lever unit is not normally mounted grease the insides of the lever unit and of the valve on wich the lever unit is to be mounted use grease for seal place the lever unit between the cam and pin until it touches adjust according the requirements and secure with the two screws 4 Nm If there are problems functioning difficulty oil leaks etc remove the lever unit when the machine is at a standstill and pressure in the hydraulic system is zero All work _on_ the power pack must be done when the machine is at a standstill and pressure in the hydraulic system is zero LIMITS Functioning Maximum flow rate 20 l min Optimal flow rate 3 15 l min Pressure min 10 bar Pressure max 250 bar for group 05 pump Pressure max 290 bar for pumps with displacement 1 2 4 3 cc rev Pressure max 260 bar for pumps with displacement 4 8 cc rev Pressure max 210 bar for pumps with displacement 6 0 cc rev Pressure max 160 bar for pumps with displacement 7
7. ve Directive ATEX 94 9 EC Assembled Power Pack Not Conforming The Power Pack can not be used in environments where there is the risk of explosion Febbraio 2007
8. viare e spegnere il motore della centralina con cicli ON OFF di 1 secondo procedere fino alla fuoriuscita dell olio dalla linea di pressione Ricollegare la linea di pressione al cilindro e rabboccare il serbatoio Effettuare diverse corse complete del cilindro per spurgare il circuito e verificare di nuovo il livello dell olio Controllare la taratura della valvola di massima INFORMAZIONI E ISTRUZIONI IMPORTANTI Fluido idraulico base minerale ISO 6743 4 viscosit ISO 3448 viscosit d esercizio 20 50 cSt temperatura d esercizio 30 60 Montaggio del serbatoio controllare la pulizia del serbatoio verificare che la guarnizione di tenuta sia in buono stato montare il serbatoio ingrassando la guarnizione di tenuta e la bocca del serbatoio con grasso per guarnizioni fissare il serbatoio Montaggio giunto su motore A C motore unificato Vedere cataloghi tecnici o consultare personale tecnico della Hydr app SpA Collegamento elettrico per motore D C Coppie di serraggio consigliate per i poli motore ISO M8 5 7 Nm Coppie di serraggio consigliate per i poli teleruttore ISO M6 3 5 Nm Prima della messa in funzione si consiglia di effettuare alcuni cicli di assestamento al teleruttore con cariche medio basse Senso di rotazione Osservando la centralina dal lato motore senso orario Montaggio gruppo leva comando manuale Il gruppo leva normalmente non montato ingrassare le parti interne del gruppo leva e della valvola sulla

Download Pdf Manuals

image

Related Search

Related Contents

  INEX Federation Manual  23ページ M-NAVI/みんなの掲示板 [PDFファイル/1004KB]  社団法人日本配電制御システム工業会  2005 CEC Focus - June Issues  

Copyright © All rights reserved.
Failed to retrieve file