1. Manual When Aqua lonic is programmed in the Manual mode this condition must be confirmed by the corresponding LED on the panel the regeneration can be activated only using the Manual Regen key placed on the panel In this operation mode too the checks concerning the volume and the conductivity are performed according to what described in the previous paragraphs Only the check on conductivity activates the alarm both on the panel and on the proper output placed in the DIN 360 socket 4 2 5 Auto Set point Manual When Aqua lonic is programmed in the Auto Set Point Manual mode this condition must be confirmed by the illumination of both LEDs on the panel the regeneration can be activated only using the Manual Regen key placed on the panel At the same moment when the conductivity value read by the probe exceeds the programmed set point value and remains above that threshold for the whole time that has been set the alarm will be activated Alarm LED on the panel and output signal on the DIN 360 socket Any volume exhausting will be ignored 4 2 6 Auto Volume Manual When Aqua lonic is programmed in the Auto Volume Manual mode this condition must be confirmed by the illumination of both LEDs on the panel s the regeneration can be activated only using the Manual Regen key on the panel When the volume exhausts the Alarm output on the DIN 360 socket activates but the corresponding LED on the panel does
2. TIMER AQUA IONIC DATI TECNICI 230 Vac 10 Tensione di alimentazione Frequenza di rete _ gt S o 50 Hz 3 Potenza assorbita 4 6 VA Temperatura operativa __ 4 C 40 C Dimensioni del contenitore 165 x 127 x 70 mm Peso complessivo da 0 8 a 1 7 Kg CERTIFICATI Compatibilit Elettromagnetica 89 336 CEE 93 68 CEE Bassa Tensione 73 23 CEE 93 68 CEE Direttiva 2002 95 EC ROHS Direttiva macchine 98 37 CE Conformit dei materiali al DM 443 90 del 21 12 1990 RIGENERAZIONE Manuale tramite un punto di set volume immediato tramite start remoto MODELLI DISPONIBILI Demineralizzazione PS0515 Al5 02 05 PS0525 AI7 02 05 PS0530 AI7 02 08 tempi programmabili Durata minima ciclo 1 min durata massima ciclo 99 minuti ABBINAMENTI POSSIBILI Demineralizzazione AI5 02 05 Al7 02 05 Al7 02 08 gt PSO015 V132D 04 PS0020 V132D 05 PS0090 V240D 04 PS0100 V240D 05 PS0146 V230D PS0162 V250D NB PS0175 V260D PS0195 V360D ACCESSORI DA ORDINARE SEPARATAMENTE PS1316 SONDA CONDUCIBILITA OPZIONI sono disponibili su richiesta altri tipi di trasformatore Es 115 12 Vac 60 Hz Prego contattare l ufficio tecnico Hytek per ulteriori informazioni AQUA IONIC CONTROLLER TECHNICAL DATA Power voltage 230 Vac 10 Network frequency 50 Hz 3 Power absorbed VA Operative temperature 4 C 40 C 165 x 127 x 70 mm from 0 8 to 1 7 Kg Con
3. Alarm e la partenza della rigenerazione Durante il servizio il controller esegue sempre il controllo fra la conducibilit e il set point anche se non pu comandare la partenza della rigenerazione Se il valore letto dalla sonda superiore al set point programmato e rimane oltre tale soglia per il tempo impostato si ha l attivazione dell allarme LED Alarm sul pannello e apposita uscita sulla presa DIN 360 4 2 3 Auto Set Point Auto Volume Quando Aqua lonic programmato in Auto Set Point Auto Volume entrambi i LED sul pannello sono accesi vengono eseguiti entrambi controlli indicati nei par 4 2 1 e 4 2 2 La rigenerazione viene attivata dal controllo che per primo raggiunge le condizioni previste per la partenza del ciclo 4 2 4 Manual Quando Aqua lonic programmato in Manual confermato dall accensione del relativo LED sul pannello la rigenerazione pu essere attivata solo con il tasto Manual Regen sul pannello Anche in questa modalit operativa rimangono invariati i controlli sul volume e sulla conducibilit secondo quanto indicato nei paragrafi precedenti Solo il controllo sulla conducibilit attiva l allarme sia sul pannello che sull apposita uscita sulla presa DIN 360 presa C quando si verificano le condizioni gi descritte 4 2 5 Auto Set point Manual Quando Aqua lonic programmato in Auto Set Point Manual confermato dall accensione di entrambi i LED sul pannello la rigener
4. N B Perch questo controllo possa essere effettuato obbligatorio programmare un tempo di almeno minuto per l ultima fase del ciclo di rigenerazione passo 15 tab 3 4 4 Programmazione La programmazione di Aqua lonic si esegue tramite il tasto Program Mode e i valori sono modificabili con il tasto Advance La programmazione procede come segue Tab 3 Tabella programmazione 1 PROG MODE 0100 Valore del set point Le cifre di destra lampeggiano 2 PROG MODE 0 1 00 Valore del set point Le cifre di sinistra lampeggiano 3 PROG MODE 0 1 00 Valore del volume Le cifre di destra lampeggiano 4 PROG MODE 0 1 00 Valore del volume Le cifre di sinistra lampeggiano 5 PROG MODE A A O 1 Il divisore del contatore 6 PROG MODE AA 08 Il tempo di ritardo dello scatto dell allarme per set point 7 PROG MODE A A 0 8 Fine della programmazione Premendo di nuovo si esce 8X0 1 CO01I tempo di stop della prima fase del ciclo di rigenerazione 9 PROG MODE 2 C 00 Il tempo di stop della seconda fase del ciclo di rigenerazione 10 PROG MODE 3 C 00 Il tempo di stop della terza fase del ciclo di rigenerazione 11 PROG MODE 4 C 0 0 Il tempo di stop della quarta fase del ciclo di rigenerazione 12 PROG MODE 5 C 0 0 II tempo di stop della quinta fase del ciclo di rigenerazione 13 PROG MODE 6 C 0 0 II tempo di stop della sesta fase del ciclo di rigenerazione 14 PROG MODE
5. are available Es 115 12 Vac 60 Hz The right hand side of the case is opened where the DIN sockets are placed Fig 9 In the event you would like to supply the controller external drivers see Fig 3 and 4 with compressed air please make sure that e The air pressure be within 1 and 6 bar and however not higher than the input water pressure e an air humidification system with water or proper silicone lubricant is mounted on the air line in order to prevent the driver internal seals from getting dry SIATA always recommends to supply the drivers with water In this case it is necessary to use an input filter to avoid impurities Please be particularly careful when installing the controller in environments that are not compliant with the EN 50082 1 standard electromagnetic compatibility 3 3 Maintenance Mind to check the battery efficiency about every 12 months as follows e Switch off the timer for at least 15 minutes e The timer disconnected from the supply voltage check the battery voltage using a multimeter If the measured voltage is less than 3 2 Vdc replace the battery with the spare part code 867 The following servicing operations must always be performed when the controller is off power In case of replacement of the electronic board only and each fime you operate on the open case please avoid as much as possible touching the components and the welded parts with your hands above all in t
6. contatti 2 3 Uscita normalmente aperta dell impulso durante la 2a fase del ciclo di rigeneraz DIN C 5 1 contatti Uscita normalmente aperta dell impulso Rigenerazione in Corso e DIN C 5 4 contatti Uscita normalmente chiusa dell impulso Rigenerazione in corso 4 10 Diagnostica Aqua lonic dotato di un sistema di diagnostica che consente all addetto alla manutenzione di conoscere lo status funzionale del controller Si accede a questa funzione tramite il tasto Advance che va tenuto premuto per almeno 5 6 secondi parametri che verranno visualizzati sono i seguenti F 001 giorni trascorsi dall ultima rigenerazione 0 0 0 4 Il numero di rigenerazioni effettuate dalla prima accensione 0000 I volume conteggiato dalla prima accensione Il numero di rigenerazioni effettuate non pu essere azzerato dall utente All interno della diagnostica si deve premere il tasto Program Mode per visualizzare i vari parametri 4 11 Taratura della sonda Il trimmer posto sul lato posteriore del controller in parte visibile in basso a destra in fig 7 consente la taratura della sonda di conducibilit Per eseguire questa operazione ci sono due metodi Il primo consiste nel mettere un resistore al posto della sonda nei morsetti 1 5 della presa DIN 270 presa B indicati in fig 9 Un resistore da 10 KOHM identificata dai colori marrone nero arancio e oro per la tolleranza simula una conducib
7. memoria eeprom dove viene memorizzata la programmazione e di una batteria tampone che consente il mantenimento in memoria dei parametri di lavoro in caso di mancanza di tensione di alimentazione Aqua lonic come tutta la gamma dei controller SIATA conforme alle Direttive CEE ed realizzato nello Stabilimento SIATA di Montespertoli operante con il Sistema Qualit certificato secondo la norma ISO 9001 UNI EN ISO 9001 2 SIGNIFICATO DEI LED E DEI TASTI Tab 1 Funzionalit dei LED SET POINT box giallo Acceso durante la rimessa del valore di set point SET POINT box blu Acceso quando il valore di conducibilit supera il valore di set point ALARM box blu SET POINT DELAY box giallo Si accende durante la programmazione quando si rimette il tempo di intervento per set point Durante il servizio si accende ad indicare una situazione di allarme EXT ALARM Si accende quando presente il segnale di inibizione AUTO SET POINT Acceso quando la rigenerazione deve partire per acqua non buona AUTO VOLUME Acceso quando la rigenerazione deve partire per volume esaurito MANUAL Acceso quando la rigenerazione non deve partire automaticamente INT ALARM Acceso quando la rigenerazione non va a buon fine Tab 2 Funzionalit dei tasti X 0 1 Premuto durante il servizio cambia l impostazione della sonda X o X 10 Premuto al termine della fase di programmazione consente di ac
8. not illuminate In this mode too the timer performs its checks on the probe reading At the same moment when the conductivity value read by the probe exceeds the programmed set point value and remains above that threshold for the whole time which has been set the alarm will activate Alarm LED on the panel and output signal on the DIN 360 socket 4 3 Checking the regeneration efficiency Pin 3 of the DIN 270 socket if connected to the ground enables the regeneration quality check which is performed during the last cycle phase Whichever the operating mode and the cause for the regeneration starting during the last cycle phase a comparison between the conductivity value read by the probe and the programmed set point value occurs when such a check begins the Int Alarm LED illuminates on the panel If the value read by the probe is lower than the set point value the last cycle phase is terminated before the expiration of the set time in order not to waste water The Int Alarm LED goes out and the controller will immediately start working If on the contrary the value read by the probe remains above the set point value for the whole duration of the last phase of the regeneration cycle the Int Alarm LED remains on and blocks the automatic performance of the successive regeneration cycles since it is evident that there are problems preventing a correct regeneration performance Only at this moment the Alarm output on t
9. rel indicato in figura deve essere connesso fra il morsetto del 12 Vdc e quello del segnale interessato nell esempio l impulso fine ciclo Riferirsi alla tabella del par 6 9 1 per sapere quali sono i segnali che escono dal controller in modalit Open Collector Il rel deve avere un assorbimento massimo per l eccitazione della bobina di 20MmA Seguono i codici di alcuni rel utilizzabili a questo scopo tutti con bobina da alimentare a 12 Vdc Modello e OMRON GdV 1 12Vdc e TAKAMISAWA MZ 12HS U e MATSUSHITA JQ1 12V o JQla 12V o HD1 M DC12V 4 9 1 Connessioni delle 3 prese DIN CONTEGGIO 3 via IMP FINE CICLO 2 INIBIZIONE 4 MASSA 1 MASSA 5 NON USATO 4 NON USATO 3 MASSA 2 START REMOTO 1 IMP FASE 2NA 3 RIG IN GORSO N C 4 RIG INGORSON A 1 RIG IN CORSO COM 5 IMP FASE 2 COM 2 In fig 9 sono indicate le connessioni delle 3 prese DIN da utilizzare come segue DIN A contatti 1 3 Volume contatore reed o con chiusura non alimentato e DIN A contatti 1 3 5 Volume contatore magnetico ad effetto Hall alimentato dalla tensione 12 Vdc DIN A contatti 1 4 Ingresso del segnale di inibizione in chiusura DIN A contatti 2 5 Uscita del segnale di Impulso Fine Ciclo in modalit Open Collector e DIN B contatti 1 2 Ingresso del segnale di Start remoto in chiusura e DIN C
10. risolta autonomamente dal controller grazie ad un circuito di autoreset che interviene dopo 5 secondi di anomalia dei segnali dal microcontrollore la seconda richiede sempre un intervento manuale Le fig 6 e 7 mostrano i punti dove intervenire per risolvere le condizioni di blocco appena indicate La prima operazione da eseguire quando il controller apparentemente spento o quando si comporta in maniera anomala il reset cosiddetto software Consiste nel mettere in corto circuito per un attimo punti Al e A2 indicati in fig 7 quando il trasformatore di alimentazione del controller connesso alla tensione di rete Se questa operazione non d risultati si Pu procedere con il secondo tipo di reset il reset hardware Consiste nel tenere in corto circuito per qualche secondo i punti B1 e B2 indicati in fig 7 quando il trasformatore di alimentazione del controller staccato dalla tensione di rete Fatto questo si deve collegare il trasformatore di alimentazione alla tensione di rete e verificare che il controller si accenda subito o dopo i 5 secondi di intervento dell autoreset Se il controller non si accende ripetere il reset software sui punti Al e A2 di fig 7 Se il controller ancora non si accende consultare il Cap 5 Fig 6 e 7 i punti dove eseguire il reset 6 9 Connessioni In fig 8 visibile l uso corretto dei segnali che escono da Aqua lonic in modalit Open Collector Il
11. subject to strong electromagnetic interferences Nonetheless it is possible to use normal cables if the distance between the controller and the probe is short or if there are not great electric interference sources in the immediate neighborhoods In any case it is advisable not to wire the probe cable near power cables Fig 6 shows the correct usage of the signals issued by Aqua lonic in the Open Collector mode The relay indicated in the figure must be connected between the terminal of the 12 Vdc and the terminal of the signal concerned in the example it is the cycle end impulse Please refer to the table of par 4 8 1 to learn which signals are issued by the controller in the Open Collector mode The maximum relay absorbency for the trio Coil excitation must be 20MA Here below follow the codes of a few relays that can be used to this purpose all of tnem with a trip coll to be supplied with 12 Vcd OMRON G5V 1 12Vde TAKAMISAWA MZ 12HS U MATSUSHITA JQ1 12V or JQ1a 12V or HD1 M DC12V 4 8 1 Connection of this version to 3 DIN sockets CONTEGGIO 3 125 IMP FINE CICLO 2 _ INIBIZIONE 4 MASSA 1 MASSA 5 NON USATO 4 NONUSATO 3 MASSA 2 START REMOTO 1 IMP FASE 2N A 3 RIG INCORSOIN C 4 RIG INGORSON A 1 RIG IN CORSO COM 5 IMP FASE 2 COM 2 Fig 7 shows the connections of the 3 DIN sockets to be used as follows e D
12. IN A 1 3 contacts Volume counter reed or with closing not powered e DIN A 1 3 5 Volume Hall effect magnetic counter powered by the tension 12 Vdc e DIN A 1 4 Input of inhibit in closing DIN A 2 5 Output of the signal of limit cycle impulse in Open Collector mode e DIN B 1 2 Input of remote starter in closing DIN C 2 3 Output normally opened of the impulse during the 2nd phase of regener Cycle DIN C 5 1 Output normally opend of the impulse of the regeneration in progress DIN C 5 4 Output normally closed of the impulse of the regeneration in progress 5 TROUBLESHOOTING Here follow some basic operations that will help solving those little problems that could arise when using the Aqua lonic As a general rule if the suggested remedies do not give any results and independently from the type of controller we suggest to check the anomaly by replacing only the electronic board with a new one or anyway with one that is certainly in a good state obviously to the extent of your possibilities It is important to be able to identify whether the cause of the malfunction is to be found in electronics mechanic part or the harness wiring Replacing the electronic board may be already a precious help to identify the real cause of the defect If our suggestions are not sufficient to solve your problems please contact the SIATA assistance service The controller does not power on e Failure
13. attare 50 000 litri di acqua Volume 5 50 000 5 0000 nei passi 4 e 5 di tab 3 Divisore x 5 AA14 x 5 AA70 nel passo 8 di tab 3 Si fa presente che programmare il volume con il valore 0000 significa programmare 10 000 programmare il divisore con il valore AA00 significa programmare il divisore per 100 Il massimo volume trattabile utilizzando il contalitri ad effetto Hall SIATA di 70 000 litri programmando 10 000 litri di volume trattabile e AA98 di divisore Se si usa un contatore che fornisce un impulso ogni litro 0 metro cubo il Massimo volume trattabile di 1 000 000 litri 0 metri cubi programmando 10 000 litri di volume trattabile e AA00 di divisore corrispondente a 100 impulsi ogni litro o metro cubo E necessario segnalare che data la natura dei contatori Reed sconsigliabile l uso di contatori limp 1m8 o similari per le caratteristiche di lettura dei controller 4 7 Installazione della sonda La sonda di conducibilit l elemento pi IMportante e delicato di Aqua lonic e la sua installazione deve essere curata con la massima attenzione Si consiglia di usare sempre un cavo schermato per realizzare il collegamento fra la sonda ed il controller Questa scelta diventa obbligatoria quando si devono coprire distanze fra il controller e la sonda superiori ai 2 metri e o quando l ambiente dove si installa il controller soggetto ad un forte inquinamento elettromagnetico Se la distanza f
14. azione pu essere attivata solo con il tasto Manual Regen sul pannello Nel momento in cui il valore di conducibilit letto dalla sonda supera n il valore di set point programmato e si mantiene oltre tale soglia per tutto il tempo impostato si avr l attivazione dell allarme LED Alarm sul pannello e segnale di uscita sulla presa DIN 360 presa C L eventuale esaurimento del volume viene ignorato 4 2 6 Auto Volume Manual Quando Aqua lonic programmato in Auto Volume Manual confermato dall accensione di entrambi i LED sul pannello la rigenerazione pu essere attivata solo con il tasto Manual Regen sul pannello Quando il volume si esaurisce si ha l attivazione dell uscita Alarm sulla presa DIN 360 presa C ma non l accensione del relativo LED sul pannello Anche in questa modalit operativa il timer esegue i controlli sulla lettura della sonda Nel momento in cui il valore di conducibilit letto supera il valore di set point programmato e si mantiene oltre tale soglia per tutto il tempo impostato si avr l attivazione dell allarme LED Alarm sul pannello e segnale di uscita sulla presa DIN 360 4 3 Controllo sull efficienza della rigenerazione Il pin 3 della presa DIN 270 presa B se connesso a Massa abilita il controllo della qualit della rigenerazione effettuato durante l ultima fase del ciclo Qualunque sia la Modalit operativa e la causa dell avvio della rigenerazione d
15. cedere alla programmazione dei tempi del ciclo di rigenerazione PROGRAM MODE Consente di accedere alle funzioni di programmazione dei parametri di lavoro ADVANCE Premuto durante la programmazione o la rimessa dell ora consente di incrementare la cifra lampeggiante sul display Premuto durante il servizio consente di visualizzare il volume residuo Tenuto premuto durante il servizio consente di accede alla diagnostica SELECT Consente di cambiare la modalit di partenza della rigenerazione MAN REGEN Permette l attivazione manuale della rigenerazione RESET Durante la programmazione consente di uscire senza salvare il parametro in modifica al momento della pressione del tasto Durante la rigenerazione ne provoca la fine TASTO NASCOSTO Posizionato sotto i 6 tasti al centro fra Advance e Volume Clock consente di avviare una rigenerazione di prova Premuto durante alcune fasi della programmazione provoca l azzeramento della cifra lampeggiante sul display 3 GENERALITA Diamo qui di seguito alcune indicazioni che devono essere rispettate durante l uso e la manutenzione del controller allo scopo di garantirne una lunga vita operativa 3 1 Imballo ed immagazzinamento L imballo costituito da una scatola con etichetta identificatrice del prodotto L iImmagazzinamento dell apparecchio deve avvenire in ambienti con le seguenti caratteristiche temperatura compresa tra 4 C e 40 C umidit
16. cks will indicate that the foreseen conditions have been reached Manual The regeneration starts only when pressing the proper key Auto Set Point Manual The timer performs the checks requested by the Auto Set point mode but it is not able to perform the regeneration in the automatic mode Auto Volume Manual The timer performs the checks requested by the Auto Volume mode but it is not able to perform the regeneration in the automatic mode 4 2 1 Auto Set Point When Aqua lonic is programmed in the Auto Set Point mode this condition must be confirmed by the illumination of the corresponding LED on the panel there is a comparison between the conductivity value and the programmed set point value steps 1 and 2 in tab 3 When the conductivity exceeds the set point value the device begins counting the set delay time step 6 tab 3 If the conductivity value does not decrease before expiration of the delay time 5 regeneration will start If the inhibition signal is present on pin 4 of the DIN 180 socket when the delay time exhausts the Ext Alarm LED is on Aqua lonic will not start regeneration and will activate the alarm Alarm LED on the panel and output signal on the DIN 360 socket At the same moment when the inhibition signal is deactivated the alarm will also be deactivated Alarm LED on the panel and output signal on the DIN 360 socket and the regeneration will start The Ext Alarm LED wi
17. ento in cui la conducibilit superiore al set point parte il Conteggio del tempo di ritardo impostato passo 6 tab 3 Se il valore di conducibilit non rientra prima dello scadere del tempo di ritardo si ha la partenza della rigenerazione se almomento dello scadere del tempo di ritardo presente il segnale di inibizione LED Ext Alarm acceso sul pin 4 della presa DIN 180 presa A Aqua lonic non parte in rigenerazione ed attiva l allarme LED Alarm sul pannello e segnale di uscita sulla presa DIN 360 presa C Nel momento in cui si disattiva il segnale di inibizione si ha la disattivazione dell allarme LED Alarm e segnale di uscita sulla presa DIN 360 e la partenza della rigenerazione ll LED Ext Alarm rester acceso ad indicare quanto avvenuto Si soegnerd al termine del ciclo di rigenerazione 4 2 2 Auto Volume Quando Aqua lonic programmato in Auto Volume confermato dall accensione del relativo LED sul pannello la rigenerazione viene eseguita all esaurimento del volume impostato Non sono disponibili funzioni di programmazione e o calcolo della riserva Se al momento dell esaurimento del volume presente il segnale di inibizione LED Ext Alarm acceso sul pin 4 della presa DIN 180 presa A Aqua lonic non parte in rigenerazione L uscita Alarm sulla presa DIN 360 presa C NON viene attivata Nel momento in Cui si disattiva il segnale di inibizione si ha lo spegnimento del LED Ext
18. fase del ciclo di rigenerazione 15 PROG MODE 8 C 0 0 II tempo di stop della ottava fase del ciclo di rigenerazione 16 PROG MODE 8 d O O La programmazione terminata Dopo 3 secondi esce 17 00 3 0 Sul display torna la visualizzazione della conducibilit In riferimento al passo 8 della tab 3 se invece di premere il tasto X 0 1 si preme il tasto Program Mode si esce dalla programmazione senza accedere alla programmazione dei tempi del ciclo di rigenerazione Quest ultima la procedura consigliata che l utente deve seguire In qualunque momento possibile premere il tasto Reset per uscire dalla programmazione senza Memorizzare le eventuali modifiche apportate al valore lampeggiante sul display In corrispondenza del passo 15 di tab 3 si ha la scrittura dei parametri programmati nella eeprom IMPORTANTE La programmazione che viene impostata secondo i passi della tab 3 non diventa immediatamente operativa Perch lo diventi operatore deve premere il tasto Reset o eseguire una rigenerazione tramite il tasto Manual Regen Se questa semplice regola non viene seguita si ottiene dal controller un comportamento conforme alla vecchia programmazione non alla nuova 4 5 Messa in servizio Aqua lonic come tutti i controller SIATA considerato in servizio quando in grado di eseguire la rigenerazione Questo possibile SOLO quando il controller sente che la camma correttamente posizionata a fi
19. ggi La sostituzione della scheda elettronica gi un valido aiuto per l individuazione della reale causa del difetto Se i suggerimenti qui presentati non riescono a dare la soluzione al problema Vi invitiamo a rivolgerVi al servizio assistenza SIATA Il controller non si accende Presa di alimentazione guasta Spina del trasformatore guasta Trasformatore guasto Verificare collegando un qualunque altro tipo di apparecchio alla stessa presa ed il controller ad un altra presa e Problema di cablaggio Aprire il box e verificare che fili siano correttamente inseriti nel connettore 7 poli e controller bloccato Se si usa la presa DIN laterale verificare che dentro la calotta del connettore non ci siano morsetti in corto circuito Seguire le indicazioni del par 4 8 Il motore non si ferma sul fine corsa e Particolari in plastica danneggiati Aprire il box e verificare l integrit delle parti in a eS di sostegno al micro switch Fig 10 e Micro switch danneggiato Aprire il box e verificare Fig 10 l integrit del micro switch il suo corretto posizionamento ll corretto posizionamento dei morsetti l integrit dei fili di collegamento l integrit della leva di azionamento del micro switch e La camma fuori posizione Aprire il box Fig 10 e verificare che il seeger metallico che trattiene la camma sia integro e ben posizionato nel suo alloggiamento Verificare che la camma azioni la leva del micro s
20. he DIN 360 socket is also activated It is possible to press the Reset or the Manual Regen keys to reset the alarm The Reset key allows to restore the correct performance of the regeneration cycles with automatic start Which will stop again if the cause preventing the performance of a correct regeneration is not identified and removed in the meantime while the Manual Regen key allows to immediately perform a new regeneration which will end again with an alarm if as just mentioned the cause of the previous alarm is not removed NOTE In order for this check to be carried out a duration of at least 1 minute must be compulsorily programmed for the last phase of the regeneration cycle step 15 tab 3 4 4 Programming Aqua lonic is programmed using the Program Mode key and the values can be modified using the Advance key Proceed as follows to perform programming Programming table Tab 3 1 PROG MODE 0 1 00 Set point value The digits on the right hand side blink 2 PROG MODE 0 1 00 Set point value The digits on the left hand side blink 3 PROG MODE 0 1 00 Volume value The digits on the right hand side blink 4 PROG MODE 0 1 00 Volume value The digits on the left hand side blink 5 PROG MODE A A O 1 The counter divider 6 PROG MODE AA 08 The delay time for the activation of the set point alarm 7 PROG MODE A A O 8 End of programming Pressing again quits 8X 0 1 1 C OO The st
21. he microprocessor area since possible electrostatic discharges could seriously damage the controller Furthermore we recommend not to place the electronic board on a metal surface unless it is properly isolated a couple of paper sheets will be sufficient To store the electronic boards please always use the anti static envelopes that come with the replacement kits Avoid the electronic board to come in contact with liquids In case it happens please dry it with an air jet 3 4 Safety devices The controller is provided with the following safety devices e Safety and isolation transformer e Safety electronic circuit against voltage peaks and disturbances 4 INSTRUCTIONS FOR USE 4 1 Powering on Aqua lonic is not provided with power switches Powering on is obtained by connecting the power transformer to the outlet 4 2 Working After powering on the display placed on the front panel will display the conductivity value read by the probe The regeneration starting modalities are the following Auto Set Point The regeneration starts at the expiration of the programmed delay time that begins to be counted when the conductivity value read by the probe exceeds the programmed threshold limit Auto Volume Immediate start when the available volume is exhausted Auto Set Point Auto Volume The timer performs both the above mentioned checks and will activate the regeneration as soon as either of the two che
22. ilit di 100uS mentre un resistore da 100 KOHM identificata dai colori marrone nero giallo e oro per la tolleranza simula una conducibilit di 10 uS Dopo aver inserito uno dei due resistori si deve agire sul trimmer in modo da ottenere sul display la lettura relativa ovvero 100 o 10 a seconda del resistore usato Il secondo metodo consiste nel confrontare la lettura della conducibilit del controller con quella di un conducimetro campione Si immerge in acqua il conducimetro campione e si annota il valore da esso indicato Quindi si IMmerge nella stessa acqua la sonda del controller e si agisce sul trimmer suindicato per avere la stessa lettura E preferibile eseguire questa operazione con acqua avente una conducibilit inferiore ai 100 uS Poich la testa della sonda di conducibilit introduce una variazione nella lettura preferibile procedere alla taratura usando il secondo metodo in quanto usando anche la sonda consente di correggerne gli effetti 5 RISOLUZIONE DEI PROBLEMI Indichiamo alcune operazioni basilari per la risoluzione dei piccoli problemi che possono insorgere durante l uso di Aqua Ionic Come regola generale suggeriamo di verificare l anomalia presentata sostituendo la sola scheda elettronica con una nuova o comunque dal funzionamento sicuro ovviamente nei limiti delle possibilit pratiche E importante poter distinguere la causa del malfunzionamento fra l elettronica la meccanica o i cabla
23. isplayed e The controller is out of program Reset the controller following instructions given in par 4 8 Fig 10 Fig 10 clearly shows the micro switch its block and command mechanical details and the terminals for connection to the controller plastic components supporting the micro
24. ll remain on to indicate the situation that has occurred until the end of the regenerative cycle 4 2 2 Auto Volume When Aqua lonic is programmed in the Auto Volume mode this condition must be confirmed by the illumination of the corresponding LED on the panel the regeneration will be performed when the set volume exhausts No reserve calculation or programming functions are available If the inhibition signal is present on the proper pin of the DIN 180 socket when the volume exhausts Ext Alarm LED on Aqua lonic will not start regeneration The Alarm output on the DIN 360 socket is NOT activated At the same moment when the inhibition signal is deactivated the Ext Alarm LED will be deactivated and the regeneration will start During operation the controller always performs a comparison between the conductivity and the set point values even though it cannot start regeneration If the value read by the probe exceeds the programmed set point value and remains above that threshold for the whole set time the alarm will activate Alarm LED on the panel and proper output on the DIN 360 socket 4 2 3 Auto Set Point Auto Volume When Aqua lonic is programmed in the Auto Set Point Auto Volume mode both LEDs on the panel are on both checks indicated in par 4 2 1 and 4 2 2 are carried out The regeneration is activated by the check which as first satisfies the conditions required for the cycle to be started 4 2 4
25. ne corsa Per poter eseguire delle prove prima dell installazione necessario che Aqua lonic sia collegato al suo box in modo che l ingresso fine corsa sia correttamente chiuso Aqua lonic non consente alcuna operazione fino a quando l ingresso fine corsa non risulta chiuso In riferimento a quanto gi indicato nel par 4 3 una volta Modificata la programmazione di Aqua lonic necessario premere il tasto Reset o eseguire una rigenerazione per poter caricare in memoria i nuovi parametri 4 6 Gestione del volume passi 3 e 4 di tab 3 indicano la programmazione del volume trattabile Utilizzando il contalitri ad effetto Hall SIATA il valore del divisore AA 14 passo 5 tab 3 deve essere programmato con il valore 14 ovvero ogni 14 impulsi dal sensore si ha il decremento medio non regolabile di un litro dal volume disponibile In questo Modo il massimo volume trattabile che possibile programmare risulta essere 10 000 litri ottenibili programmando 0000 nei passi 4 e 5 di tab 3 Se si ha l esigenza di utilizzare un volume superiore possibile ricorrere ad una semplice operazione aritmetica ovvero raddoppiare triplicare quadruplicare ecc il divisore e contemporaneamente dividere per due per tre per quattro ecc il volume trattabile Esempi e Si devono trattare 15 000 litri di acqua Volume 2 15 000 2 7500 nei passi 4 e 5 di tab 3 Divisore x 2 AA14 x 2 AA28 nel passo 8 di tab 3 e Si devono tr
26. of the supply outlet Failure of the transformer plug Failure of the transformer Connect any other kind of device to the same outlet and the controller to another outlet e Problem in the cable connection Open the case and check that the wires be properly inserted in the 7 pole connector e The controller is blocked If you use the side DIN socket check for any short circuited terminals in the connector cap Follow instructions given in par 4 8 The motor does not stop at the limit stop e Damages in the plastic components Open the case and check whether the switch are integer Fig 10 e The micro switch is damaged Open the case and check whether Fig 10 the micro switch is integer it is placed correctly the terminals are placed correctly the connection wires are integer the micro switch starting lever is integer e The cam is out of place Open the case Fig 10 and check that the metal seeger holding the cam be integer and correctly placed in its casing Turn the cam with your hand to check whether it activates the micro switch lever The controller does not perform regeneration e The controller is not correctly programmed Check that the programming has been performed correctly and that the regeneration start corresponds to the really necessary one e The controller is inhibited If you are using the DIN socket Fig 9 check for any short circuited terminals in the connector cap Wrong parameters are d
27. onic non dotato di interruttori di alimentazione L accensione si ottiene collegando il trasformatore di alimentazione alla presa di corrente 4 2 Funzionamento Dopo l accensione il display posto sul pannello frontale visualizzer il valore di conducibilit letto dalla sonda Le modalit di partenza della rigenerazione sono Auto Set Point La rigenerazione parte allo scadere del tempo di ritardo programmato che inizia a scorrere quando il valore di conducibilit letto dalla sonda supera il valore di guardia programmato Auto Volume Partenza immediata all esaurimento del volume disponibile Auto Set Point Auto Volume Il timer esegue entrambi i controlli sopra indicati e attiver la rigenerazione appena uno dei due controlli indicher il raggiungimento delle condizioni descritte Manual La rigenerazione parte esclusivamente alla pressione dell apposito tasto Auto Set Point Manual Il timer esegue i controlli richiesti dal funzionamento Auto Set point ma non pu eseguire la rigenerazione in modo automatico Auto Volume Manual timer esegue i controlli richiesto dal funzionamento Auto Volume ma non pu eseguire la rigenerazione in modo automatico 4 2 1 Auto Set Point Quando Aqua lonic programmato in Auto Set Point confermato dall accensione del relativo LED sul pannello confronta il valore di conducibilit e il valore di set point programmato passi 1 e 2 tab 3 Nel mom
28. ontrollers is considered as operational when able to perform resins regeneration This is possible ONLY when the controller senses that the cam is correctly positioned at the stop In order to perform a few tests before installation it is necessary to connect Aqua lonic to its case in order that the limit switch input be correctly closed Aqua lonic does not allow to perform any operations until the limit switch input is closed With reference to what already stated in par 6 3 once the Aqua lonic programming has been modified it is necessary to press the Reset key or to perform a regeneration in order to load the new parameters into the memory 4 6 Managing the volume steps 3 and 4 of tab 3 describe how to program the treatable volume Using the SIATA Hall effect liter counter the value of the divider AA14 step 5 tab 3 must be set to 14 which means that the available volume is reduced in a not adjustable way by one liter every 14 impulses issued by the sensor In this way the maximum treatable volume that can be programmed is 10 000 liters If you need to use a larger volume it is possible to do a simple arithmetical operation that is to multiply by two by three by four etc the divider and at the same time divide by two by three by four etc the treatable volume Examples e You have to treat 15 000 liters water Volume 2 15 000 2 7500 in steps 4 and 5 of Tab 3 Divider x 2 AA14 x 2 AA28 in s
29. ontrollo sull efficienza della batteria come segue e Spegnere il timer per circa 15 minuti e Tenendo il timer staccato dalla tensione di alimentazione controllare la tensione di batteria con un multimetro Se la tensione misurata inferiore ai 3 2 Vdc sostituire la batteria con il ricambio cod 86 7 Le seguenti operazioni di manutenzione devono sempre essere eseguite a controller spento In caso di sostituzione della sola scheda elettronica ed ogni qualvolta ci si trovi a dover agire sul box aperto evitare il pi possibile di toccare con le mani i componenti e le saldature soprattutto nella zona del microprocessore poich eventuali scariche elettrostatiche potrebbero causare seri malfunzionamenti del controller Inoltre bene evitare di appoggiare la scheda elettronica su un piano di metallo a meno che non sia adeguatamente isolata sono sufficienti un paio di fogli di carta Per l immagazzinamento delle schede elettroniche usare sempre le buste antistatiche dentro le quali vengono consegnati i kit di ricambio Evitare che la scheda elettronica venga a contatto con liquidi Se questo avviene procedere alla sua asciugatura con getto d aria 3 4 Dispositivi di protezione Il controller dotato delle seguenti protezioni e Trasformatore di isolamento e sicurezza e Circuito elettronico di protezione dai picchi di tensione e dai disturbi e Circuito di Autoreset 4 ISTRUZIONI PER L USO 4 1 Accensione Aqua l
30. op of the regenerative cycle first phase 9 PROG MODE 2 C 0 0 The stop of the regenerative cycle second phase 10 PROG MODE 3 C 00 The stop of the regenerative cycle third phase 11 PROG MODE 4 C 0 0 The stop of the regenerative cycle fourth phase 12 PROG MODE 5 C 00 The stop of the regenerative cycle fifth phase 13 PROG MODE 6 COO The stop of the regenerative cycle sixth phase 14 PROG MODE 7 C OO The stop of the regenerative cycle seventh phase 15 PROG MODE 8 C 0 0 The stop of the regenerative cycle eighth phas 16 PROG MODE 8 d 0 O End of programming It quits after 3 seconds 17 00 30 The display shows the conductivity again Pressing the Program Mode key instead of the X 0 1 key at step 8 of tab 3 will quit programming without accessing the regenerative cycle phases The latter is the recommended procedure It is possible to press the Reset key at any time to quit programming without storing any changes made to the value flashing on the display At step 15 of tab 3 the programmed parameters are written in the eeprom IMPORTANT The programming which is set according to the tab 3 steps becomes operational only when the user presses the Reset key or performs a regeneration using the Manual Regen key Neglecting this simple procedure will result in a behavior compliant with the previous programming not with the new one 4 5 Starting operations Aqua lonic as well as all SIATA c
31. play When pressed during operation it allows to display the residual volume SELECT It allows to change the regeneration start mode MAN REGEN It allows to activate the regeneration manually RESET During programming it allows to quit without saving the parameter being modified when the key is pressed During regeneration it ends if HIDDEN KEY Placed below the 6 keys in the middle between Advance and Volume Clock it allows to start a test regeneration When pressed during some programming phases it zeroes the digit blinking on the display 3 GENERAL INFORMATION Please find herewith below some instructions to be followed during the controller usage and maintenance in order to ensure its long term operativity 3 1 Packaging and storage The package consists in a box with a product identification label The device must be stored in environments compliant with the following characteristics temperature within 4 C e 40 C relative humidity within 30 and 95 3 2 Installation The controller installation must be performed by qualified technical staff the installation procedures must be performed when the device is off power The device consists in an ABS case closed on front by a cover blocked with 4 screws As an optional a transparent cover is available that can be used as a keyboard protection The controller is supplied by a 230 12 Vac transformer Upon request other types of transformer
32. ra la sonda ed il controller breve in alternativa al cavo schermato possibile usare il cavo twistato ovvero con i due fili che formano una treccia dentro la guaina esterna tipo il cavo telefonico In ogni caso buona norma evitare di cablare il cavo della sonda vicino ai cavi di potenza due fili del cavo devono essere montati sui contatti esterni pin 1 e 5 del connettore DIN 270 presa B e la calza metallica deve essere collegata alla carcassa metallica come visibile in fig 5 4 8 Reset Il controller pu essere influenzato dai seguenti eventi la batteria scarica una perturbazione elettromagnetica eccezionalmente forte oltre i limiti imposti dalla norma EN 50082 1 la manipolazione della scheda con le mani un corto circuito fra le connessioni delle prese DIN Questi eventi possono causare uno dei seguenti problemi il fuori programma o il latch up Nel primo caso la memoria RAM interna al microcontrollore viene sporcata dall evento perturbatore con risultati imprevedibili si pu avere il blocco totale del controller un comportamento anomalo o ancora l alterazione dei parametri di funzionamento Nel secondo caso il microcontrollore autonomamente si porta in una condizione particolare denominata appunto latch up che gli consente di proteggersi da potenziali danneggiamenti La differenza fra queste due condizioni che la prima nella Maggioranza dei casi viene
33. relativa tra 30 e 95 3 2 Installazione L installazione del controller deve essere effettuata da personale qualificato le procedure di installazione devono essere eseguite ad apparecchio non alimentato L apparecchio costituito da un box in ABS chiuso frontalmente da una mascherina fissata con 4 viti e protetta da un coperchio trasparente Il controller alimentato con un trasformatore 230 12 Vac Sono disponibili su richiesta altri tipi di trasformatore Es 115 12 Vac 60 Hz Il lato destro del box aperto in corrispondenza delle prese DIN Fig 9 Fig 4 Nel caso si desideri alimentare i piloti esterni del controller Vedi Fig 3 e 4 con aria compressa occorre accertarsi che e la pressione dell aria di comando sia compresa fra 1 e 6 bar e comunque non sia superiore alla pressione dell acqua in iNgresso e sulla linea dell aria di comando sia montato un sistema di umidificazione dell aria con acqua o adeguato lubrificante siliconico allo scopo di non causare l essiccamento delle guarnizioni interne al pilota SIATA raccomanda sempre di alimentare i piloti con acqua IN questo caso occorre un filtro in Ingresso contro le impurit Si consiglia di porre particolare attenzione nella installazione del controller in ambienti che non sono conformi ai limiti contenuti nella norma EN 50082 1 compatibilit elettromagnetica 3 3 Manutenzione E buona norma ogni 12 mesi circa eseguire un c
34. s is compliant with the EEC Directives and is built in the SIATA factory in Montespertoli Florence Italy working with the Quality System certified according to the following standard ISO 9001 UNI EN ISO 9001 2 MEANING OF LEDs AND KEYS LED functionality Tab 1 SET POINT yellow case It is on during the set point value setting SET POINT blue case It is on when tne conductivity value surpasses the set point value ALARM blue case SET POINT DELAY yellow case It goes on during programming when setting the set point intervention time During operation it illuminates to indicate an alarm condition EXT ALARM It is on when the inhibition signal is present AUTO SET POINT It is on when the regeneration must start because water is not good AUTO VOLUME It is on when the regeneration must start because of exhausted volume MANUAL It is on when the regeneration must not start automatically INT ALARM It is on when regeneration is not successful Key functionality Tab 2 X 0 1 When pressed during operation it changes the setting of the X 1 or X 10 probes When pressed at the end of the programming phase it allows to access the programming of the regeneration cycle phases PROGRAM MODE It allows to access the programming functions of the working parameters ADVANCE When pressed during programming or time setting it allows to increase the digit blinking on the dis
35. tainer dimensions Total weight CERTIFICATIONS Electromagnetic Compatibility 89 336 CEE 93 68 CEE Low Voltage 73 23 CEE 93 68 CEE Directive 2002 95 EC RoHS Directive macchine 98 37 CE All materials are according to al DM 443 90 of 21 12 1990 MODALITY OF REGENRERATION Manual Regeneration start by sey point Regeneration start by volume AVAILABLE MODELS Demineralization PS0515 AI5 02 05 PS0525 Al7 02 05 PS0530 Al7 02 08 time cicles programmable time cicles minimum 1 min time cicles max 99 min POSSIBLE COMBININGS Filtration Al5 02 05 Al7 02 05 Al7 02 08 gt PSO015 V132D 04 PS0020 V132D 05 PS0090 V240D 04 PS0100 V240D 05 PS0146 V230D PS0162 V250D NB PS0175 V260D PS0195 V360D ACCESSORIES TO BE ORDERED SEPARATELY PS1316 CONDUCTIVITY PROBE OPTIONS Are available other types of transformer Es 115 12 Vac 60 Hz Please contact Hytek Technical Office for further information Fig 1 1 CARATTERISTICHE DI BASE Aqua lonic comanda valvole multivia SIATA per la realizzazione di impianti di trattamento acque Il ciclo di rigenerazione interamente programmabile ed attivato in uno dei seguenti modi dopo un tempo programmabile durante il quale la sonda rileva acqua non buona immediatamente all esaurimento del volume trattabile manualmente tramite il tasto Manual Regen immediatamente tramite il segnale esterno di Start Remoto Aqua lonic dotato di una
36. tep 8 of tab 3 When starting operations the treatable volume will be 7500 liters e You have to treat 50 000 liters water Volume 5 50 000 5 0000 in steps 4 and 5 of tab 3 Divider x 5 AA14 x 5 AA70 in step 8 of Tab 3 When starting operations the treatable volume will be 0000 liters 10000 Please note that programming the volume by setting the 0000 value means programming 10 000 while setting the AAOO value for the divider means programming the divider as 100 You can treat maximum 70 000 liters water with the SIATA Hall effect liter counter by programming 10 000 liters for the treatable volume and AA98 for the divider If you use a counter issuing one impulse every liter or cubic meter the maximum treatable volume will be 1 000 000 liters or cubic meters if you set to 10 000 liters the treatable volume and to AA00 the divider corresponding to 100 impulses every liter or cubic meter Please note that because of the Reed counters characteristics we recommend not to use limp 1m3 or similar counters 4 7 Installing the probe The conductivity probe is the most important element of Aqua lonic and its installation must be performed with the highest care A screened cable is always the best choice to connect the controller to the probe This choice is compulsory when the distance between the controller and the probe is over 2 meters and or when the environment where the controller is being installed is
37. urante l ultima fase del ciclo si ha il confronto fra il valore della conducibilit letto dalla sonda e il valore del set point impostato l inizio di questo controllo evidenziato dall accensione del LED Int Alarm sul pannello sonda inferiore al valore di set point l ultima fase del ciclo viene terminata prima dell esaurimento del tempo impostato allo scopo di non sprecare acqua Il LED Int Alarm viene spento e il controller entra immediatamente in servizio Se invece il valore letto dalla sonda rimane superiore al valore di set point per tutto il tempo dell ultima fase del ciclo di rigenerazione il LED Int Alarm resta acceso e blocca l esecuzione automatica dei successivi cicli di rigenerazione poich evidente che ci sono dei problemi che impediscono la corretta rigenerazione dell impianto solo in questo momento viene attivata anche l uscita Alarm sulla presa DIN 360 presa C Per azzerare l allarme possibile premere il tasto Reset oppure il tasto Manual regen Il primo consente di ripristinare la corretta esecuzione dei cicli di rigenerazione a partenza automatica che si bloccheranno nuovamente se nel frattempo non stata individuata e rimossa la causa che impedisce l esecuzione di una corretta rigenerazione il secondo consente di eseguire immediatamente una nuova rigenerazione che terminer nuovamente con un allarme se come appena visto non stata rimossa la causa dell allarme precedente
38. witch ruotandola amano Il controller non rigenera e ll controller programmato male Verificare la correttezza della programmazione e che la Modalit di partenza della rigenerazione corrisponda a quella effettivamente necessaria e Il controller inibito Se si sta usando la presa DIN Fig 9 verificare che dentro la calotta del connettore non ci siano corto circuiti fra i Morsetti Vengono visualizzati dei parametri errati e controller fuori programma Occorre resettare il controller seguendo le indicazioni del par 4 8 In fig 10 sono ben visibili il micro switch i suoi particolari meccanici di fissaggio e comando e i morsetti di collegamento con il controller pic e a 4 DI Fig 1 1 GENERAL CHARACTERISTICS Aqua lonic manages SIATA multi way valves for the creation of water treatment devices The regenerative cycle which is completely programmable can be activated in either of the following ways after a programmable time during which the probe detects that the water is not good immediately when the treatable volume is exhausted manually using the Manual Regen key immediately by means of the Remote Start external signal Aqua lonic is provided with an eeprom memory where the programming is stored and of a buffer battery allowing to keep the working parameters in the memory in the event of a supply voltage failure Aqua lonic as well as all the other SIATA controller