Nbg-12lsp Pulsador manual

image

Contents

1. Q NOTIFIER by Honeywell NBG 12LSP Manual Pull Station Patented U S Patent No Des 428 351 6 380 846 Other Patents Pending Document 51015 2 156 2837 001 Description AAA t The NBG 12LSP pull station is a non coded dual action manual pull station with a key lock reset feature and dual language Spanish English labeling and operating instructions It provides Notifier control panels with one normally open N O alarm initiating input The NBG 12LSP meets the ADAAG controls and operating mechanisms guidelines section 4 1 3 13 and the ADA requirement for a 5 lb maximum pull force to activate the pull station Molded Terminal numbers are also present Ratings EES Switch contact N O is gold plated for reliability and rated at 0 25 A at 30 volts AC or DC Installation The NBG 12LSP pull station can be surface mounted to an SB 10 or SB I O surface backbox or semi flush mounted on a standard single gang double gang or 4 10 16 cm square electrical box The optional BG TR trim ring can be used 1f the NBG 12LSP is to be semi flush mounted Operation AA To activate the dual action pull station push in and pull down on the handle The word ACTIVATED appears after the handle is pulled down This will remain until the pull sta tion is reset The pull station includes one Single Pole Single Throw SPST Normally Open N O switch which closes upon activation of the pull station Resetting the Pull Stati
2. e la puerta de la estaci n pulsadora durante la instalaci n La puerta de la estaci n no podr ser reatada a la placa posterior despues de que la placa posterior haya sido instalada sobre una caja el ctrica Precauci n T Instale la estaci n pulsadora del Notifier NBG 12LSP de acuerdo con estas instrucciones apli cando las normas de la NFPA y los c digos y requisitos de fuego locales y nacionales de la AHJ Autoridad teniendo la juridicci n Se deben conducir pruebas regulares de los dispositivos uti lizando las normas apropiadas de acuerdo a la NFPA La falla de seguir estas instrucciones puede resultar en la falla del dispositivo para reportar una condici n del alarma Notifier no es responsible por dispositivos que hayan sido instalados probados o mantenidos inapropiadamente ADA Conformidad A Para el cumplimiento con la ADA si el espacio del piso vac o permite solamente el alcance frontal a un objeto la altura m xima del alcance frontal permitida es de 48 pulgadas 121 92 cm Si el espacio del piso vac o permite el alcance paralelo por una persona en silla de ruedas la altura m xima de lado permitida es de 54 pulgadas 137 16 cm
3. ompliance if the clear floor space only allows forward approach to an object the maximum forward reach height allowed is 48 inches 121 92 cm If the clear floor space allows parallel approach by a person in a wheelchair the maximum side reach allowed is 54 inches 137 16 cm Q NOTIFIER by Honeywell NBG 12LSP Estaci n Pulsadora Manual Patented U S Patent No Des 428 351 6 380 846 Other Patents Pending Documento 51015 2 156 2837 001 Descripci n 2022 La estaci n pulsadora NBG 12LSP es una estaci n no c dificada y de doble acci n manual con la caracter stica de reajuste de una cerradura de llave la cual incluye un duo de lengua Espa ol Ingles etiquetado e Instrucciones de operaci n Esta provee a los paneles de control de Notifier con una alarma de iniciaci n de entrada normalmente abierta N O El BG 12LSP reune las normas de control y funcionamiento de la ADAAG secci n 4 1 3 13 y los requisitos de ADA para que la estaci n pulsadora sea activada con una fuerza de jale m xima de 5 libras Los n meros moldeados de las terminales tambi n est n presentes Par metros de Contacto del Interruptor E El contacto del interruptor N O es oro plateado para la confiabilidad y clasificado en 0 25 A en 30 voltios AV o DC Instalaci n SSS La estaci n pulsadora NBG 12LSP puede se montada en la superficie del respaldo de un SB 10 o un SB I O esta tambi n puede ser semi montada en una caja el ctrica cuadrada
4. on 1 Insert the key into the lock and rotate 1 4 turn counterclockwise 2 Open the door until the handle returns to normal 3 Close and lock the door Note Closing the door automatically resets the switch to the Normal position Opening the door will not activate or deactivate the alarm switch Wiring EEE NBG 12LSP To Next Manual Pull Station From FACP Device Document 51015 2 156 2837 001 IDC IDC STRIP GAUGE Jp ll P0105 00 NOTIFIER by Honeywell P0264 00 terminals Break wire run to ARNING Do not loop wiring under any maintain IDC supervision CAUTION Do not detach the door of the pull station during installation The door of the pull station cannot be reattached to the backplate after the backplate has already been installed onto an electrical box CAUTION IN_ rrr Install the Notifier NBG 12LSP pull station in accordance with these instructions applicable NFPA standards national and local Fire and Electrical codes and the requirements of the AHJ Authority Having Jurisdiction Regular testing of the devices should be con ducted in accordance with the appropriate NFPA standards Failure to follow these directions may result in failure of the device to report an alarm condition Notifier is not responsible for devices that have been improperly installed tested or maintained ADA Compliance H____________ T For ADA c
5. ya sea indi vidual o doble de 4 10 16 cm El anillo opci nal BG TR puede ser usado si el NBG 12LSP va a ser semi montado Funci namiento IA Para activar la estaci n pulsadora de doble acci n simplemente empuje hacia adentro y tire hacia abajo la manija manubrio La palabra ACTIVATED aparecer despu s que la manija haya sido tirada hacia abajo Esta permanecer hasta que la estaci n pulsadora sea reajustada La estaci n pulsadora incluye un poste individual un interruptor individual SPST Normalmente Abierto N O el cual se cierra en la activaci n de la estaci n pulsadora Reajuste de la Estaci n Pulsadora SSE 1 Inserte la llave dentro de la cerradura y dele 1 4 de giro en sentido contrario a las manecillas del reloj 2 Abra la puerta hasta que el manubrio regrese a la posici n normal 3 Cierre y asegure la puerta Nota Al cerrar la puerta el interruptor es reajustado automaticamente a la posici n Normal El abrir la puerta de la estaci n no activara o desactivar el interruptor de la alarma Alambrado JE Hacia el Proximo Desade FACP Dispositivo STRIP GAUGE Ab Q nori ER by Honeywell 2 EN NBG 12LSP T A gt Estaci n Pulsadora Manual dvertencia No enlace el cablea o debajo de los terminales Rompa la corrida de Documento 51015 2 156 2837 001 cable para mantener la supervisi n Precauci n SE No se separ