Home

DM-1016FinalSpanEngRev 4 - Watts Water Technologies

image

Contents

1. 2 La instalaci n y prueba DEBE ser efectuada por personal calificado Aseg rese que el suministro de gas y que todas las perillas de control del aparato est n cerrados antes de conectarlo al suministro de gas 3 La salida del gas debe estar en el mismo cuarto que el aparato y el conector no debe estar oculto en ni instalado a trav s de una pared piso o divisi n Las conexiones flexibles de gas no deben hacer contacto con superficies de temperatura mayor de 110 C 230 F bordes filosos o cables 4 El ensamblado final debe ser probado buscando fugas PRECAUCION No deben usarse llamas abiertas u otras fuentes de igni ci n para buscar fugas Las soluciones para detecci n de fugas pueden provocar corrosi n ENJUAGUE CON AGUA DESPU S DE LA PRUEBA Para buscar fugas en el sistema de tuber a de suministro de gas vea el C digo Nacional de Gas Combustible Z223 1 NFPA 54 o CSA B149 1 C digo de Instalaci n de Gas Natural y Gas Propano Si detecta olor a gas cierre el gas del aparato y haga que un profesional certificado corrija el problema 5 ADVERTENCIA LAS SOLUCIONES DE LIMPIEZA O SUSTANCIAS QU MICAS FUERTES NO DEBEN ENTRAR EN CONTACTO CON EL CONECTOR Estas pueden incluir cidos solventes purgantes con cloruro de cinc u otros qu micos clorados En caso de contacto enjuague el conector con agua y seque completamente 6 Se debe instalar una v lvula manual de cierre accesible en la salida del sistema de tuber a del suministro
2. NOTE The gas valve cannot be turned to the on position until the gas appliance connector is properly attached Diagram 1 Off Position Diagram 2 On Position Shut Off Valve Safety Nipple Coupling Sleeve GAS Flow Safety Quik with Double Swivel MAX A Apply thread sealant pipe dope to the threads of the gas connector at both ends Insert the male threads of the gas connector into the female threads of the Swivel MAX fitting on each end of the connector Gas Supply Side B Apply thread sealant pipe dope to the male threads of a Swivel MAX fitting Separate the Safety Quik nipple male from the Safety Quik coupling female Thread the male end of the Swivel MAX into the Safety Quik nipple Tighten Appliance Side C Apply thread sealant pipe dope to the male stub out of the appliance Thread the street elbow onto the stub out D Apply thread sealant pipe dope or thread tape to the male threads of the street elbow Insert male threads into f x f threaded coupling not included E Apply thread sealant pipe dope to the male threads of the Swivel MAX Insert threads into female threaded coupling Tighten E Insert Safety Quik nipple into Safety Quik coupling to complete the connection G Check tightness of all connections Leak test in accordance with accepted testing procedures Rinse H After the installation of the connector carefully push the appliance back to its normal operating po
3. asegur ndose que no entre en el acople de desconexi n r pida o en la l nea de gas ninguna sustancia extra a grasa soluci n limpiadora o suciedad Reconexi n de la L nea de Gas Conecte nuevamente el acople de desconexi n r pida al insertar el extremo del tap n empalme en el acople Conecte nuevamente el cable de retenci n Conecte nuevamente cualquier cord n el ctrico Gire la palanca de la v lvula esf rica del gas a la posici n de abierto Cuidadosamente empuje el equipo hacia la pared asegur ndose que el conector de gas no se tuerza ni se doble en un ngulo agudo Verifique que el conector de gas no sea da ado o aplastado por el equipo si ste le pasa por encima Si se necesita encienda nuevamente la llama del piloto Encienda el equipo Soporte de Ingenier a de Dormont El equipo de Ingenier a de Dormont est disponible para ayudarle con el dise o y disposici n de las instalaciones de equipo de cocina Podemos dise ar la conexi n de gas apropiada para que funcione con su equipo y de acuerdo a las necesidades de su cocina p A A Go N Fe RD D D 7 On ma Dormont ha trabajado con consultores cadenas nacionales y fabricantes de equipo para solucionar los problemas m s dif ciles de instalaciones de gas Los diagramas CAD anteriores son solamente algunos ejemplos del tipo de soporte t cnico que ofrece mos Para mayores detalles comun quese con nuestros Especialistas en Servicios al Cl
4. se entiende que dicho reemplazo se efectuar solamente despu s de la devoluci n del art culo defectuoso de acuerdo a las instrucciones de embarque del Vendedor y con la autorizaci n de devoluci n y estar sujeta a la inspecci n por parte del Vendedor ii El Comprador no asignar sus derechos bajo estas garant as expresas y cualquier intento de asignaci n anular dichas garant as pero no cualquier descargo o limitaci n y que los bienes ser n vendidos TAL COMO EST N y iii todos los conectores comerciales de gas y otros bienes a su arribo ser n inspeccionados cuidadosamente por el Comprador buscando da os ser n instala dos por personas capacitadas y certificadas como profesionales en dichas instala ciones y ser n instaladas usadas reparadas y mantenidas por el Comprador de acuerdo a los c digos o reglamentos locales normas fijadas por el Instituto Norteamericano de Normas Nacionales y o las Normas de la Asociaci n Norteamericana de Gas Los conectores comerciales de gas y otros bienes estar n garantizados en conjunto con la instalaci n original solamente y las garant as y recursos expresos aqu contenidos no se aplicar n a y ser n nulos sin mayor conse cuencia da o y o falla de los conectores comerciales de gas y otros bienes provo cados por o como resultado del flete manejo instalaci n alteraci n o reparaci n inapropiados o no autorizados mal uso abuso u otros incidentes o condiciones que no se
5. 2 installation quick disconnect at the gas supply side the female coupling part of the quick disconnect coupling must be upstream and attached to the gas supply El LO Gas Supply Side A Apply thread sealant pipe dope or thread tape to the threads at one end of the gas connector B Thread the gas connector end into the quick disconnect male nipple K Tighten with wrenches C Separate the quick disconnect female coupling J from the male nipple K I Figure 2 a D Apply thread sealant pipe dope or thread tape to the valve nipple E Thread the quick disconnect female coupling onto the threads of the pipe nipple from the gas shut off valve Tighten with wrench Appliance Side E Apply thread sealant pipe dope or thread tape to the appliance s stub out F and thread the elbow onto stub out Tighten G Apply thread sealant pipe dope or thread tape to the male threads of the street elbow Insert male threads into f x f threaded coupling not included H Apply thread sealant pipe dope or thread tape to the gas connector threads Thread hose into the coupling Tighten with wrench I Connect quick disconnect male nipple K to the female coupling J J Check tightness of all connections Leak test in accordance with accepted testing procedures K After installation of the connector carefully push the appliance back to its normal operating position Check that the connector is not kinked over bent or caught u
6. 86 600 3 4 pulg 232 000 180 000 139 000 3 4 pulg 290 900 215 000 173 900 1 pulg 414 000 334 000 279 000 1pulg 581 800 442 700 347 800 1 1 4 pulg 699 000 541 000 419 000 1 1 4 pulg 1 075 500 817 500 634 000 Nota La capacidad fue determinada bajo condiciones de prueba especificadas por ANSI 721 69 Nota Cuando use una ca da de presi n de columna de agua de 0 2 la capacidad puede ser determinada al multiplicar la cifra anterior por 0 632 Para capacidades y condiciones diferentes de las anotadas comun quese con su proveedor de servicio de gas CA D Safety gt system D rmont 6015 Enterprise Drive Export PA 15632 USA 724 733 4800 FAX 724 733 4808 1 800 DORMONT 367 6668 www dormont com IOM D 1016 1202
7. A PARA DESCONECTAR Cierre la v lvula para cerrar el gas Retraiga la HE manga y saque el empalme IMPORTANTE EL ACOPLE NO SE DEBE USAR COMO EL CIERRE PRINCIPAL DIRECCION DEL FLUJO DE GAS OPCI N 2 Sas Dispositivo de Desconexi n R pida Instalado en el Suministro de Gas Este m todo de instalaci n usado com nmente en Europa muestra el acople de desconexi n r pida fijo en el lado del suministro de gas El acople DEBE estar siempre en el lado del suministro de gas fijo a la tuber a del lado del suministro Esto le permite al oper ador alejar el equipo de la pared en un conjunto de equipo y a desconectar con seguridad el conector de gas de la l nea de suministro de gas Entrada de la Tuber a de la Salida Macho del Aparato Casa Cable de Retenci n V lvula Esf rica de Gas de Puerto Completo Acople de Desconexi n Conector de Gas Safety R pida hembra System GQ Empalme de Desconexi n Acople de d a cod R pida macho DIRECCION DEL FLUJO DE GAS cople de desconexi n r pida SnapFast di Codo a 90 Instalaci n del Cable de Retenci n Instrucciones de Instalaci n del Cable de Retenci n Este dispositivo de retenci n debe estar conectado siempre que el aparato est en servicio El dispositivo de retenci n debe ser desconectado para mover el aparato por ejemplo para el mantenimiento y limpieza nicamente despu s de que el gas haya sido cerrado y se haya des
8. DEBE seguir las flechas de direcci n del flujo que est n mar cadas indeleblemente en el acople E Aplique un sellador de roscado barniz para tuber a o cinta para roscado en las roscas macho del conector de gas Enrosque el acople de desconexi n r pida en las roscas del conector de gas Apriete G Conecte el acople hembra de desconexi n r pida H en el empalme macho I Figura 1 a H Revise el apretado de todas las conexiones Busque fugas de acuerdo a los procedimientos de prueba aceptados I Despu s de la instalaci n del conector empuje con cuidado el aparato de regreso a su posici n normal de operaci n Verifique que el conector no est acodado muy doblado o atrapado bajo las ruedas del equipo 11 OPCION 2 Desconexi n R pida fija en el lado de la l nea de suministro de gas Desconexi n R pida Invertida Vea la Figura 2 en la p gina siguiente ADVERTENCIA Si decide seleccionar la Opci n 2 de la instalaci n desconexi n r pida del lado del sumin istro de gas la parte hembra del acople de desconexi n r pida debe estar corriente arriba y fijo al suministro de gas Lado del Suministro de Gas A Aplique un sellador de roscado barniz para tuber a o cinta para roscado en las roscas localizadas en el extremo del conector de gas B Enrosque el extremo del conector de gas en el empalme macho de desconexi n r pida K Apriete con una llave C Separe el acople hembra de desconexi n r pida J del e
9. Pl stico 4 WET hy F Perno ACIERTO Fije la longitud del dispositivo de retenci n de tal man era que el conector no se acode cuando el dispositivo de retenci n est completamente extendido Para los dispositivos de retenci n ajustables el cable est dise ado para que sea m s corto que la longitud del conector de gas 5 se MAK LOS ACCESORIOS SWIVEL MAX ESTAN CERTIFICADOS EN SU DISE O PARA USARSE SOLAMENTE CON CONECTORES DE GAS DORMONT 1 No esconda el accesorio en ni lo pase por paredes pisos o divisiones 2 Para usarse en sistemas de tuber a que tengan presiones de gas combustible no mayores de 1 2 psig 3 Instale SOLAMENTE corriente abajo de la v lvula manual de cierre del suministro de gas 4 Cuando instale un accesorio Swivel MAX use sellador de roscado barniz para tuber a sola mente NO USE CINTA DE TEFLON EN EL ACCESORIO NO SOBREAPRETAR Conexi n del Aparato con Swivel MAX Sencillo NOTA El Swivel MAX est fijo al extremo del suministro de gas del conector Lado del Suministro de Gas A Aplique un sellador de roscado barniz para tuber a en las roscas localizadas en el extremo del conector de gas Inserte este extremo del conector de gas en la rosca hembra del accesorio Swivel MAX B Aplique un sellador de roscado barniz para tuber a en la rosca macho del Swivel MAX Enrosque ha extremo del conector de gas en la rosca hembra de la v lvula de cierre de gas y apriete c
10. but are not limit ed to loss of profits loss of use of the goods damage to property and claims of third parties Some states do not allow the exclusion or limitation of incidental or con sequential damages or any limitations on how long an implied warranty lasts so the above exclusion or limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Notice and Time of Claim i Buyer agrees to check and inspect all products against shipping papers and for damage or shortage upon receipt of goods at destination ii Every claim for loss damage in transit or other cause visible upon inspection shall be made with car rier Claims for shortage must be made within five 5 days of receipt iii The parties expressly waive the statute of limitations and agree that any legal pro ceeding for any breach of this contract shall be waived unless held within two 2 years after the accrual of the cause of action therefor 80 9001 2008 REGISTERED 11 INSTALLATION FOR DUAL FED FRONT MANIFOLD EQUIPMENT LINE UP WHEN INSTALLING AN EQUIPMENT LINE UP WITH DUAL FED FRONT MANIFOLD GAS INLET Do not use a Safety Quik or SnapFast quick disconnect coupling for this type of installation The use of a quick disconnect coupling for this installation may be dangerous and is not recommended WARNING Unless upstream gas shut off valves on both inlet lines are
11. completely closed the uncoupling of one quick dis connect will result in an open gas flow A Safety System flexible gas connector s without the quick disconnect coupling may be used All installation instructions in this booklet describe installations that exclude the use of an external appli ance gas regulator If one is required thread the regulator onto the appliance stub out prior to installing the street elbow Afterwards thread the female threads of the regulator and street elbow using a male to male pipe nipple Once complete continue installation according to the remaining instructions Recommended Operating Instructions Cleaning Behind Equipment I Disconnecting the Gas Line 1 Turn off the equipment 2 Carefully pull the equipment away from the wall stopping when the restraining cable is taut 3 Shut off the gas supply by turning the lever on the gas ball valve located off the main manifold line to the off position Unplug any electrical cords 4 Disconnect the gas line by pulling back the sleeve of the quick disconnect coupling Be careful not to drop the coupling on the floor which may damage the unit Detach the snap hook of the restraining cable Carefully pull the equipment away from the wall 7 Clean behind the equipment making sure no foreign substance grease cleaning solution or dirt enter the quick disconnect coupling or gas line II Reconnecting the Gas Line 1 Reattach the quick dis
12. equipo SwIiveIMAXK Lazo de Combinaci n Pared Suministro de Gas de Alto Nivel Pared Suministro de Gas de Alto Nivel Equipo Conexi n de Entrada Posterior Baja Equipo Conexi n de Entrada Posterior Alta Recomendaci n Recomendaci n Instalaci n del Kit Swivel MAX V lvula de Protecci n de Desconexi n Doble Modelo 1675KIT2S48 R pida Safety Quik con accesorios de Dormont Swivel MAX Dobles de Dormont Instalaci n Modelo 1675KITCF2S48 Safety Quik con Swivel MAX Sencillo A Aplique un sellador de roscado barniz para tuber a o cinta para roscado en las roscas localizadas en un extremo del conector de gas Inserte la rosca macho del conector de gas en la rosca hembra del accesorio Swivel MAX Lado del Suministro de Gas B Aplique un sellador de roscado barniz para tuber a o cinta para roscado en la rosca macho del accesorio Swivel MAX Separe el empalme Safety Quik macho del acople Safety Quik hembra Enrosque el extremo macho del Swivel MAX en el empalme Safety Quik Apriete Lado del Aparato Aplique un sellador de roscado barniz para tuber a o cinta para roscado en la salida macho del aparato Enrosque el codo de rosca macho y hembra en la salida Aplique un sellador de roscado barniz para tuber a o cinta para roscado en la rosca macho del codo de rosca macho y hembra Inserte las roscas macho en el acople de rosca hembra x hembra no incluido Aplique un sellador de roscado b
13. gas has been shut B Two Snap Hooks EE COS off and the connector has been disconnected Reconnect restraining cable before reconnecting the gas connector C Staple Bracket G 1 4 Hex Nut and moving back to its original position D 1 10 Screws 4 H 1 4 Nvlon Lock Nut RESTRAINING CABLE PTER 1 Restraining Device should be installed parallel in line with E Plastic Anchors A 1 4 x 1 1 4 Washers 2 the gas appliance connector 2 Attach the staple bracket C to a stud in the wall using the four 1 10 screws D and the plastic anchors E a if needed payee Q 3 Locate a structural area frame on the rear side of the equipment that is in line with the wall attachment Drill a 1 4 diameter hole Use caution when drilling hole so that internal components are not damaged 4 Thread the hex nut G and a washer I onto the eye bolt F Slide one washer onto the nut Slide the eye bolt through the drilled hole and place a washer I and the nylon lock nut H onto the eye bolt on the inside frame of the equipment and tighten securely 5 Attach one of the snap hooks B to the staple bracket on the wall Step 2 above and the other to the eye bolt Steps 3 and 4 above tep 4 Set the length of the restraining device so that the connector is not kinked when the restraining device is fully extended Note For adjustable restraining devices the cable is manufactured to be shorter than
14. ii a R vid e Codo de Rosca Macho y si dais F gura 1 a Hembra a 90 ds 3 9a NOTA Existen dos opciones para la orientaci n de los empalmes de desconexi n r pida OPCION 1 desconexi n r pida en el aparato OPCION 2 desconexi n r pida en el sistema de tuber a 10 OPCION 1 Desconexi n R pida fijada al lado del aparato Vea la Figura 1 Lado del Suministro de Gas A Aplique un sellador de roscado barniz para tuber a o cinta para roscado en las roscas localizadas en el extremo del conector de gas B Enrosque este extremo del conector de gas en la v lvula de cierre y apriete con una llave Lado del Aparato C Aplique sellador de roscado barniz para tuber a o cinta para roscado en la salida macho del aparato F y enrosque el codo de rosca macho y hembra E en la salida macho y apriete con una llave Puede variar mucho la ubicaci n tanto de la salida del equipo como de la T para el m ltiple de la l nea de suministro de gas D Aplique un sellador de roscado barniz para tuber a o cinta para roscado en las roscas macho del codo de rosca macho y hembra E E Separe el extremo macho del acople de desconexi n r pida o empalme 1 del extremo hembra o acople H Enrosque el empalme macho 1 en el codo de rosca macho y hembra E y apriete NOTA El acople de desconexi n r pida DEBE ESTAR ORIENTADO de tal manera que el gas entre por la parte del conector y salga por el empalme El personal de instalaci n
15. must follow the flow direction arrows that are permanently marked on the coupling 14 NEVER INSERT screwdrivers probes etc into the quick disconnect coupling The valve seat can be damaged or forced off center 15 The connector shall not be kinked twisted or torqued when installed 16 Make sure that all fittings are tightened properly When installing Safety System gas connector two 14 inch adjustable wrenches minimum size are recommended as installation tools 17 Adequate means must be provided to limit the movement of castered appliances A restraining device is REQUIRED for all types of moveable gas appliances ANSI Z223 1 amp ANSI Z21 69 18 The recommended restraining device for castered appliances is Dormont s Restraining Device Installation instructions for this Dormont product are part of this booklet This restrainer should be inspected as part of the regular maintenance and safety procedures Restraining cable MUST BE connected at all times when appliance is in use Follow the instructions on page 4 19 When installing an equipment line up with dual fed front manifold gas inlets DO NOT use a quick disconnect coupling 20 For installations that require greater mobility Dormont Swivel MAX gas connector assemblies are recommended 21 Appliance MUST BE disconnected prior to maximum movement Warning DO NOT OVEREXTEND the gas connector assembly When moving equipment for cleaning maintenance etc follow the
16. so that the gas enters the female valved coupling half and exit the male nipple half FOLLOW the flow direction arrows permanently marked on the coupling FIGURE 1 OPTION 1 Sas QD Device Installed at the Appliance This installation method commonly used in North America shows the quick disconnect coupling attached at the appliance side The nipple MUST always be on the appliance side attached to the appliance stub out or external regulator This enables the operator to move the equip ment away from the wall in an equipment line up and safely disconnect the gas connector from the back side of the appliance O Gas Supply Line Q Appliance Male Gas Manifold Stub Out Gas Shut Off Ball Valve Restraining Device O Q Safety System Gas Quick Disconnect gt Il o il zip Connector Coupling female H O SnapFast Quick O Quick Disconnect GAS FLOW DIRECTION Disconnect Nipple male O 90 Street Elbow Figure la 3 9a NOTE There are two options for the orientation of the quick disconnect couplings OPTION 1 quick disconnect at the appliance OPTION 2 quick disconnect at the piping system 10 OPTION 1 Quick Disconnect attached at the appliance side Refer to Figure 1 Gas Supply Side A Apply thread sealant pipe dope or thread tape to the threads at one end of the gas connector B Thread this end of the gas connector into the gas shut off valve and tighten with wrenches Appliance Side C A
17. 00 541 000 6 pies 84 000 168 800 337 600 615 500 4 pies 102 900 208 700 429 800 793 600 NOTA Cuando use una ca da de presi n de columna de agua de 0 2 la capacidad puede ser determinada al multiplicar la cifra anterior por 0 632 Para capacidades y condiciones diferentes de las anotadas comun quese con su proveedor de servicio de gas NOTA La capacidad fue determinada bajo condiciones de prueba especificadas por ANSI Z21 69 10 w C ANSI Z21 69 CSA 6 16 Conectores Met licos para Aparatos M viles de Gas ANSI Z21 41 CSA 6 9 Dispositivos de Desconexi n R pida para uso con gas combustible E ANSI Z21 15 CGA 9 1 s V lvula Manual de Gas para Aparatos V lvulas para Conectores de Aparatos y V lvulas para Mangueras NSF Internacional Equipo especial criterio C 2 Solamente en los modelos recubiertos con PVC NSF CR 92 009 Conectores Giratorios para uso con Conectores de Aparatos M viles de Gas Certificaciones CANADA Dise o certificado de acuerdo a ANSI U L 567 Conectores de Tuber a para L quidos Combustibles e Inflamables y Gas LP Para uso con gas natural y propano Aprobaciones Aprobado por la Junta de Examinadores Estatales de Plomeros y Trabajadores del Gas del Estado Mancomunado de Massachussets La longitud del conector no debe sobrepasar los 91 4 cm y no se permiten v lvulas de palanca RE Ciudad de Nueva York MEA 274 02 E Conformidad CSA B149
18. 1 C digo de Instalaci n de Gas Natural y Propano ANSI Z223 1 NFPA 54 C digo Nacional de Gas Combustible Garant a Garant as y Recursos a Garant a El Vendedor le garantiza al Comprador que posee y traspasa el t tulo de mercanc a de los conectores comerciales de gas aqu vendidos Adem s el Vendedor le garantiza al Comprador que el conector comercial de gas del Vendedor estar libre de defectos en los materiales y mano de obra que puedan provocar una fuga de gas durante la vida til del equipo al cual sea originalmente conectado o instalado el conector comercial de gas Garant a limitada de por vida El Vendedor le garantiza al Comprador que los art culos y componentes fabricados por el Vendedor que no sean los conectores comerciales de gas estar n libres de defectos en los materiales y mano de obra por un per odo de cinco 5 a os a partir de la fecha de entrega al Comprador Para los art culos no fabricados por el Vendedor la nica garant a que se extiende es la del fabricante o proveedor de los mismos si la hubiere b Exclusiones y Condiciones Las obligaciones del Vendedor con respecto a las garant as y recursos expresos aqu contenidos est n condicionados a lo siguiente i La responsabilidad del Vendedor y el nico recurso del Comprador est limitado expresamente al reemplazo por parte del Vendedor del conector de gas defectuoso u otros bienes a expensas del Vendedor excluyendo mano de obra y flete
19. 49 1 Natural Gas Installation Code and CAN CGA B149 2 Propane Installation Code 9 The connector complies with the Standard for Connectors for Moveable Gas Appliances ANSI Z21 69 CGA 6 16 10 A restraining cable MUST BE connected at all time when appliance is in use Connector Capacity Straight Length Capacity BTU per Hr 0 64 SG Straight Length Capacity BTU per Hr 0 64 SG 1000 BTU per Cu Ft Gas at 1000 BTU per Cu Ft Gas at 0 5 in Water Column Pressure Drop 0 5 in Water Column Pressure Drop Nominal Connector re us i m m 1 D inches att Att 6ft 1 2 150 000 106 000 86 600 1 2 87 000 68 000 99 000 3 4 290 900 215 000 173 900 3 4 232 000 180 000 139 000 581 800 442700 347 800 A a 1 1 4 1 075 500 817 500 634 000 1 1 4 699 000 941 000 419 000 Note When using 0 2 water column pressure drop capacity can be Note Capacity was determined under test conditions specified determined by multiplying the figures above by 0 632 For capacities by ANSI 221 69 at conditions other than noted contact your servicing gas supplier Avertissement Instructions de montage au Canada 1 La sortie de gaz doit se trouver dans la m me pi ce que l appareil a gaz et le connecteur ne doit pas tre masqu par un mur le sol ou une cloison ni traverser une de ces structures 2 Utiliser toutes les pi ces du connecteur union fournies avec le connecteur et ne pas essayer de monter les crous du connecteur union directement aux filetages au
20. ALVULA ESFERICA DE GAS QUE SE NECESITA INSTALAR EN EL MULTIPLE DEL SUMINISTRO DEGAS PARA CADA PIEZA DEL EQUIPO DE COCINA NO LA INSTALE EN EL EXTREMO DEL EQUIPO DEL CONECTOR DE GAS DEBE INSTALARSE EN LA SALIDA DEL SISTEMA DE TUBERIA DEL SUMINISTRO DE GAS CORRIENTE ARRIBA DEL CONECTOR Lado del Gas A Aplique un sellador de roscado barniz para tuber a o cinta para roscado en las roscas macho de la salida del m ltiple de gas B Aseg rese que la palanca de la v lvula de cierre Safety Quik est en posici n de CERRADO C Fije la v lvula de seguridad Safety Quik a la entrada macho del m ltiple Apriete con una llave D Quite el empalme del Safety Quik al tirar hacia atr s del collar de la manga de seguridad cuando la v lvula est en posici n de cerrado E Aplique barniz para tuber a o cinta para roscado en las roscas macho del conector de gas E Inserte la rosca macho en el empalme Safety Quik Apriete con una llave Lado del Aparato G Aplique sellador de roscado barniz para tuber a o cinta para roscado en la salida macho del apara to y enrosque el codo de rosca macho y hembra en la salida macho Puede variar mucho la ubi caci n tanto de la salida del equipo como de la T para el m ltiple de la l nea de suministro de gas H Fije el acople roscado hembra x hembra no incluido en el codo de rosca macho y hembra Apriete con una llave I Aplique un sellador de roscado barniz para tuber a en las roscas macho loc
21. DOrmont DETSE Y Gas Connector Installation Instructions for Moveable Equipment Featuring the Blue Hose with StressGuard Technology WARNING Please read the following instruction booklet carefully Failure to fully read instructions and follow the cautions and warnings could result in severe injury or death CAUTIONS AND WARNINGS 1 The installation MUST BE in compliance with the National Fuel Gas Code ANSI 7223 1 and all local gas installation codes 2 Installation and testing MUST BE performed by qualified personnel Ensure that the gas supply and all the appliance control knobs are turned off before connecting to the gas supply 3 Gas outlet shall be in same room as appliance and the connector must not be concealed within or run through any wall floor or partition Flexible gas connections shall not come into contact with surfaces at temperatures in excess of 110 C 230 F sharp edges or wiring 4 The final assembly shall be tested for leaks CAUTION Open flame or other sources of ignition shall not be used for this purpose Leak test solutions may cause corrosion WATER RINSE AFTER TEST To check gas supply piping system for leakage see National Fuel Gas Code Z223 1 NFPA 54 or CSA B149 1 Natural Gas and Propane Gas Installation Code If odor of gas is detected turn off the gas to the appliance and have a qualified professional correct the source of the leak 5 WARNING STRONG CLEANING SOLUTIONS OR CHEMICAL SUBSTANCES MUST
22. NOT COME IN CONTACT WITH THE CONNECTOR These may include acids solvents fluxes with zinc chloride or other chlorinated chemicals In case of contact rinse down the connector with water and dry thoroughly An accessible manual shut off valve must be installed at the outlet of the gas supply piping system upstream of the connector Contact with foreign objects wiring or substances shall be avoided Avoid movement after installation on fixed appliances Bending and flexing of connectors on moveable appliances e g those factory equipped with casters should be limited to pulling and pushing the appliance in or out for cleaning or maintenance 10 Connectors are for use only on piping systems having fuel gas pressure not in excess of 1 2 psi 3 5 kPa for the US and 1 psi 7kPa for Australia Flexible connections are suitable for use with Ist 2nd and 3rd family gases only on piping systems operating at a pressure not exceeding 50 mbar 11 DO NOT REUSE FOR ANOTHER APPLIANCE OR AT ANOTHER LOCATION 12 In addition to the main gas supply shut off valve an approved accessible manual gas shut off valve MUST BE installed upstream of the gas connector within 6 feet of the equipment it serves Each piece of equipment must have its own shut off valve DO NOT USE the quick disconnect coupling is as the primary gas shut off 13 WARNING The quick disconnect MUST BE INSTALLED so that the gas enters the coupling half and exits the nipple half You
23. X Doble A Aplique un sellador de roscado barniz para tuber a en las roscas localizadas en ambos extremos del conector de gas Inserte la rosca macho del conector de gas en la rosca hembra del accesorio Swivel MAX en cada extremo del conector Lado del Suministro de Gas B Aplique un sellador de roscado barniz para tuber a en la rosca macho del accesorio Swivel MAX Separe el empalme Safety Quik macho del acople Safety Quik hembra Enrosque el extremo macho del Swivel MAX en el empalme Safety Quik Apriete Lado del Aparato C Aplique un sellador de roscado barniz para tuber a en la salida macho del aparato Enrosque el codo de rosca macho y hembra en la salida D Aplique un sellador de roscado barniz para tuber a o cinta para roscado en la rosca macho del codo de rosca macho y hembra Inserte las roscas macho en el acople de rosca hembra x hembra no incluido E Aplique un sellador de roscado barniz para tuber a en la rosca macho del Swivel MAX Inserte la rosca en el acople de rosca hembra Apriete E Inserte el empalme Safety Quik en el acople Safety Quik para completar la conexi n G Revise el apretado de ale las conexiones Busque fugas Je acuerdo a los procedimientos de prueba aceptados Enjuague H Despu s de la instalaci n del conector empuje con cuidado el aparato de regreso a su posici n nor mal de operaci n Verifique que la conexi n no est acodada muy doblada o atrapada bajo las ruedas del
24. a hembra Aplique un sellador de roscado barniz para tuber a o cinta para roscado en las roscas del empalme de la tuber a no se suministra la longitud preferida es de 7 5 cm Enrosque el empalme en la T hembra de la l nea principal del gas Luego enrosque la v lvula de cierre en el empalme y apriete bien con una llave 9 ADVERTENCIA El acople de Desconexi n R pida SnapFast D DEBE estar orientado de tal manera que el gas entre por la parte hembra del conector con v lvula y salga por la parte macho o empalme SIGA las flechas de direcci n del flujo que est n marcadas indeleblemente en el acople Diagrama 1 descentrado FIGURA 1 OPCI N 1 Sriqpfast Dispositivo de Desconexi n R pida Instalado en el Aparato Este m todo de instalaci n usado com nmente en Norteam rica muestra el acople de desconexi n r pida fijo en el lado del aparato El empalme DEBE estar siempre al lado del aparato fijo a la salida del mismo o al regulador exter no Esto le permite al operador alejar el equipo de la pared en un conjunto de equipo y a desconectar con seguridad el conector de gas de la parte posterior del aparato O L nea de Suministro de Q Salida Macho del Gas M ltiple de Gas Aparato V lvula Esf rica de Dispositivo de GAS Cierre del Gas Ramncion T O Conector de gas Safety Acople de Desconexi n H EA E Syscem R pida hembra ee ee a Desconexi n R pida DIRECCION DEL FLUJO DE GAS SnapFast O
25. alizadas en el extremo del aparato del conector de gas Apriete con una llave J Inserte la rosca macho del conector de gas en el acople con rosca hembra Apriete con una llave K Despu s de la instalaci n busque fugas de gas en las conexiones de acuerdo a los procedimientos de prueba aceptados Enjuague la soluci n despu s de la prueba C mo Usar la V lvula de Protecci n de Desconexi n R pida Safety Quik PARA DESCONECTAR 1 Gire la palanca de giro f cil de la v lvula a la posici n de cerrado Diagrama 1 La palanca debe estar perpendicular al conector de gas del aparato 2 Empuje la Manga de Seguridad hacia la palanca Esto har que la unidad se desconecte NOTA El conector de gas del aparato no debe ser desconectado hasta que la v lvula se encuentre en posici n de cerrado PARA RECONECTAR 1 Empuje firmemente el empalme de desconexi n r pida fijado al conector de gas del aparato dentro del cuerpo del acople Diagrama 2 Esto permitir que la manga de seguridad regrese a su posici n original 2 Gire la palanca de la v lvula a la posici n de abierto para permitir que el gas fluya al aparato paralelo con el conector de gas del aparato NOTA La v lvula de gas no puede ser abierta hasta que el conector de gas del aparato est fijo de manera apropiada Diagrama 1 Posici n de Cerrado Diagrama 2 Posici n de Abierto V lvula de Cierre Empalme Manga de Seguridad Safety Quik con Swivel MA
26. an el uso normal la aplicaci n o conformidad con los c digos o reglamentos locales no dados a conocer previamente al Vendedor o accidente u otro incidente Descargo de Garant as Impl citas El Vendedor no otorga ninguna garant a excepto aqu llas contenidas expresamente aqu El Vendedor niega cualquier otra garant a impl ci ta por ley costumbre de la industria trato o desempe o incluyendo pero sin limitarse a las garant as impl citas de comerciabilidad e idonei dad para un prop sito en particular Limitaciones de Responsabilidad Las siguientes limitaciones de la responsabilidad del Vendedor son reconocidas por las partes como justas y razonables y se aplicar n a cualquier acto u omisi n mencionadas posteriormente y a cualquier incumplimiento de este contrato del cual forman parte estos t rminos y condiciones Descargo de Da os En ning n caso ser responsable el Vendedor por da os especiales indirectos conse cuenciales o incidentales que resulten bajo contrato garant a perjuicio negligencia responsabilidad estricta o cualquier otra teor a de responsabilidad Tales da os incluyen pero no se limitan a la p rdida de ganancias p rdida del uso de los bienes da o a la propiedad y reclamaciones de terceras partes Algunos Estados no permiten la exclusi n o limitaci n de da os incidentales o consecuenciales o cualquier limitaci n en la duraci n de la garant a impl cita as que la exclusi n o limitaci
27. arniz para tuber a o cinta para roscado en las roscas macho del conector de gas Inserte la rosca en el acople de rosca hembra Apriete Inserte el empalme Safety Quik en el acople Safety Quik para completar la conexi n Revise el apretado de todas las conexiones Busque fugas de acuerdo a los procedimientos de prueba acep tados Enjuague Despu s de la instalaci n del conector empuje con cuidado el aparato de regreso a su posici n normal de operaci n Verifique que la conexi n no est acodada muy doblada o atrapada bajo las ruedas del equipo E Qe 41 0 Aciertos y Errores en la Instalaci n ERROR Evite las vueltas pronunciadas y acodados cuando retire el equipo de la pared Retirar al m ximo acodar los extremos a n si est n instalados apropiadamente y reducir la vida til del conector ACIERTO Retiro m nimo del equipo de la pared que permita el acceso a la Desconexi n R pida Safety Quik ERROR ACIERTO ACIERTO VUELTAS PRONUNCIADAS Instale la manguera de metal pr la columna desplazable con una vuelta sencilla natural Evite as vueltas pronunciadas que forcen y tuerzan la manguera de metal hasta un punto de falla prematura en el acople TORCEDURA Los acoples y la manguera deben ser instalados en el mismo plano vertical No hacerlo puede provocar torceduras y esfuer zos mayores que provoquen la falla prematura i AUTO DRENAJE En todas las instalaciones donde no se nece sita el auto dre
28. as l neas de entrada est n completamente cerradas la desconexi n de un acople de desconexi n r pida puede provocar un flujo abierto de gas Se puede usar un os conector es flexible s Safety System sin el acople de desconexi n r pida Todas las instrucciones de instalaci n en este folleto describen las instalaciones que excluyen el uso de un regulador externo para aparato de gas Si necesita uno enrosque el regulador en la salida del aparato antes de instalar el codo con rosca macho y hembra Posteriormente enrosque la rosca hembra del regulador y el codo con rosca macho y hembra usando un empalme macho a macho Una vez que lo haga contin e la instalaci n de acuerdo a las instrucciones restantes Instrucciones Recomendadas de Operaci n Limpieza detr s del Equipo I Desconexi n de la Linea de Gas 1 Apague el equipo 2 Retire cuidadosamente el equipo de la pared deteni ndose cuando el cable de retenci n est tirante Cierre el suministro de gas al girar la palanca en la v lvula esf rica del gas a la posici n de cerrado localizada a un lado de la l nea del m ltiple al Desconecte cualquier cord n el ctrico 4 Desconecte la l nea de gas al tirar hacia atr s la manga del acople de desconexi n r pida Tenga cuidado de no dejar caer el acople al piso lo cual da ar a la unidad 5 Quite el gancho del cable de retenci n 6 Retire cuidadosamente el equipo de la pared 7 Limpie detr s del equipo
29. conectado el conector Vuelva a conectar el cable de retenci n antes de volver a conectar el conector de gas y de moverlo nuevamente a su posici n original CABLE DE RETENCI N 1 El Dispositivo de Retenci n debe estar instalado en paralelo en l nea con el conector de gas del aparato 2 Fije la abrazadera de grapa C en un cepo de la pared usando los cuatro tornillos de 1 pulg 10 D y los anclajes de pl stico E si es necesario 3 Localice un rea estructural marco en la parte posterior del equipo que est en l nea con la abrazadera en la pared Perfore un orificio de 4 pulg de di metro Tenga cuidado cuando perfore el orificio para no da ar los componentes internos 4 Enrosque la tuerca hexagonal G y una arandela 1 en el perno F Coloque una arandela en la tuerca Deslice el perno a trav s del orificio perforado y coloque una arandela I y la contratuerca de nylon H en el perno dentro del marco del equipo y apriete bien 5 Fije uno de los ganchos de seguridad B a la abrazadera de grapa en la pared Paso 2 anterior y el otro al perno Pasos 3 y 4 anteriores Nota A Cable de Retenci n con sn A Th y B Dos Ganchos de ES ul OP LS Seguridad cele C Abrazadera de 3 Grapa e G Tuerca Hexagonal de 1 4 pulg D Tornillos de 1 pulg 10 4 H Contratuerca de Nylon de 1 4 pulg I Arandelas de 1 4 x 1 1 4 pulg 2 9 ST REH Ea LA Li E Anclajes de
30. connect coupling by inserting the plug nipple end into the coupling Reattach the restraining cable Reattach any electrical cords Turn the lever on the gas ball valve to the on position Carefully push the equipment back towards the wall be sure that the gas connector is not twisted or kinked in a severe angle Check that the gas connector is not damaged or crushed by the equipment rolling over it If required relight the pilot light Turn the equipment on Dormont Engineering Support The Dormont Engineering team is available to help with the design and layout of foodservice equipment installations We can design the proper gas connection to work with your equipment and kitchen requirements Os Un o o Un GW N o o e e ON ma Dormont has worked with consultants national chains and equipment manufacturers to solve tough gas installations problems The previous CAD drawings are just a few examples of the kind of technical support we can provide Contact one of our Customer Service Specialists at 1 800 DORMONT 367 6668 for details Return Pol cy No returns are to be made to Dormont Manufacturing Company without first obtaining a return authorization number Absolutely no returns will be accepted or credited without this prior approval Returns will be subject to a 25 restocking charge plus any transportation charges incurred WARNING Canadian Installation Instructions The quick disconnect m
31. connectors and other goods shall be warranted in conjunction with the original installation only and the express warranties and remedies contained herein shall not apply to and shall be void and of no further force or effect upon damage and or failure of the commercial gas connectors and other goods caused by or resulting from shipping improper or unauthorized handling installation alteration or repair misuse abuse or other occurrences or conditions other than normal use thereof application or conformity to local codes or regu lations not previously made known to Seller or accident or other casualty Disclaimer of Implied Warranties Seller gives no warranties except those expressly contained herein Seller disclaims all other warranties implied by law usage of the trade course of dealing or course of performance including but not limited to the implied warranties of merchantability and fitness for a particu lar purpose Limitations of Liability The following limitations of Seller s liability are acknowledged by the parties to be fair and reasonable and shall apply to any act or omission hereunder and to any breach of this contract of which these terms and conditions form a part Disclaimer of Damages In no event shall seller be liable for special indirect consequential or inciden tal damages whether arising under contract warranty tort negligence strict liability or any other theory of liability Such damages include
32. de gas corriente arriba del conector 7 Se debe evitar el contacto con objetos extra os cables o sustancias 8 Evite el movimiento posterior a la instalaci n de aparatos fijos 9 Debe limitarse el doblado o flexi n de los conectores en los aparatos m viles p ej los equipados con ruedas de f brica a sacar o meter el aparato para limpieza o mantenimiento 10 Los conectores deben usarse solamente en sistemas de tuber a que tengan una presi n del gas combustible que no sobrepase psi 3 5 kPa en los EE UU y 1 psi 7 kPa en Australia Las conexiones flexibles son adecuadas para usarse con gases de 17 2 y 3 familia solamente en sistemas de tuber a que operan a presiones no mayores de 50 milibares 11 NO LO REUTILICE EN OTRO APARATO O EN OTRO SITIO 12 Adem s de la v lvula principal de cierre del suministro de gas DEBE instalarse una v lvula manual de cierre de gas accesible y aprobada corriente arriba del conector de gas a no m s de 1 8 m 6 pies del equipo al que da servicio Cada componente del equipo debe tener su propia v lvula de cierre NO USE el acople de desconexi n r pida como el cierre principal del gas 13 ADVERTENCIA El acople de desconexi n r pida DEBE INSTALARSE de tal manera que el gas entre por la parte del conector y salga por el empalme Debe seguir las flechas de direcci n del flujo que est n marcadas indele blemente en el acople 14 NUNCA INSERTE destornilladores sondas etc en el acople de
33. desconexi n r pida El asiento de la v lvula puede da arse o descentrarse 15 Al instalarse el conector no debe estar acodado torcido o doblado 16 Aseg rese que todos los accesorios est n apretados apropiadamente Cuando instale el conector de gas Safety System se recomienda usar dos llaves pericas de 35 5 cm tama o m nimo como herramientas de instalaci n 17 Se deben proveer los medios adecuados para limitar el movimiento de los aparatos con ruedas Se REQUIERE un dispositivo de retenci n en todos los tipos de aparatos m viles de gas ANSI Z223 1 y ANSI 721 69 18 El dispositivo de retenci n recomendado para los aparatos con ruedas es el Dispositivo de Retenci n de Dormont Las instruc ciones de instalaci n de este producto Dormont son parte de este folleto Este restrictor deber inspeccionarse como parte del mantenimiento regular y de los procedimientos de seguridad El cable de retenci n DEBE estar conectado siempre que se use el aparato Siga las instrucciones de la p gina 4 19 Cuando instale un conjunto de equipo con entradas de gas del m ltiple frontal de alimentaci n doble NO use el acople de desconexi n r pida 20 Para las instalaciones que requieren de mayor movilidad se recomiendan los conectores de Gas Swivel MAX de Dormont 21 El aparato DEBE estar desconectado antes de moverlo al m ximo Advertencia NO ESTIRE DE MAS el conector de gas Cuando mueva el equipo para limpieza mantenimiento etc
34. e Gas Appliances 10 Un cable de retenue doit etre fixe en tout temps lorsqu on utilise l appareil CAPACIT DU CONNECTEUR Capacit d une section droite Btu h CAPACIT AVEC DISPOSITIF DE BRANCHEMENT RAPIDE Gaz de densit de 0 64 1000 Btu pi cu avec une chute de pression Capacit d une section droite Btu h w de 0 5 po de colonne d eau Gaz de densit de 0 64 1000 Btu pi cu Diam int nominal avec une chute de pression de 0 5 po de colonne d eau du connecteur po 2 pi 4 pi 6 pi Diam int nominal du connecteur po 2 pi 4 pi 6 pi 1 2 po 150 000 106 000 86 600 3 4 po 290 900 215 000 173 900 1 2 po 87 000 68 000 99 000 1 po 581 800 442 700 347 800 3 4 po 232 000 180 000 139 000 1 1 4 po 1075 500 817 500 634 000 1 po 414 000 334 000 279 000 1 1 4 po 699 000 541 000 419 000 D rmont 6015 Enterprise Drive Export PA 15632 EE UU 724 733 4800 FAX 724 733 4808 1 800 DORMONT 367 6668 www dormont com DOrmont rhin i Instrucciones de Instalaci n del Conector de Gas para Equipo Movil con la Tecnologia de Manguera Azul con StressGuard ADVERTENCIA Por favor lea cuidadosamente el siguiente folleto de instrucciones El no leer las instrucciones por completo ni seguir las precauciones y advertencias puede provocar lesiones graves o la muerte PRECAUCIONES Y ADVERTENCIAS 1 La instalaci n DEBE cumplir con el C digo Nacional de Gas Combustible ANSI Z223 1 y con todos los c digos de instalaci n local de gas
35. e Safety Quik nipple Tighten with wrench Appliance Side G Apply thread sealant pipe dope or thread tape to the appliance s male stub out and thread street elbow onto male stub out The location of both the equipment stub out and the tees for the gas supply line manifold can vary greatly H Attach threaded coupling f x f not included to the street elbow Tighten with wrench I Apply thread sealant pipe dope to the male threads at the appliance end of the gas connector Tighten with wrench J Insert male gas connector threads into the female threaded coupling Tighten with wrench K After installation check gas connections for leaks in accordance with accepted testing procedures Rinse off solution after test How to Use the Safety Quik Quick Disconnect Protection Valve TO DISCONNECT 1 Turn the easy turn valve handle to the off position Diagram 1 Handle should be perpendicular to the gas appliance connector 2 Push the Safety Sleeve toward the handle This will cause the unit to disconnect NOTE The gas appliance connector cannot be disconnected until the valve is in the off position TO RECONNECT 1 Firmly push the quick disconnect nipple attached to the gas appliance connector into the coupling body Diagram 2 This will allow the safety sleeve to return to its original position 2 Turn the valve handle to the on position to allow gas flow to the appliance parallel with the gas appliance connector
36. el MAX installation instructions C E and G I To MOOW 6 Installation Examples pa nr x De RS LA i E P ae Panna sd a pr En mm gt VERTICAL LOOP HORIZONTAL LOOP Wall Medium Level Gas Supply Wall Floor Level Gas Supply Equipment Rear High Inlet Connection Equipment Rear Low Inlet Connection RECOMMENDATION RECOMMENDATION Dormont Double Swivel Kit Installation Dormont Single Swivel Kit Installation Model 1675KIT2S48 Model 1675KITS48 Installation Instructions for Gas Appliance Connector Installing a Safety Quik Quick Disconnect Protection Valve NOTE THE SAFETY QUIK QUICK DISCONNECT PROTECTION VALVE IS THE GAS BALL VALVE THAT IS REQUIRED TO BE INSTALLED AT THE GAS SUPPLY MANIFOLD FOR EACH PIECE OF COOKING EQUIPMENT DO NOT INSTALL AT THE EQUIPMENT END OF THE GAS CONNECTOR MUST BE INSTALLED AT THE OUTLET OF THE GAS SUPPLY PIPING SYSTEM UPSTREAM OF THE CONNECTOR Gas Side A Apply thread sealant pipe dope or thread tape to the male threads of the drop off on the gas manifold B Make sure the handle of the Safety Quik shut off valve is in the OFF position C Attach the Safety Quik valve to the male manifold drop Tighten with wrench D Remove the nipple of the Safety Quik by pulling back on the safety sleeve collar when the valve is in the off position E Apply pipe dope or thread sealant tape to the male threads of the gas connector E Insert the male threads into th
37. fects in material and workmanship for a period of five 5 years from tender of delivery to Buyer For items not manufactured by Seller the only warranty extended is that of the manufacturer or suppliers if any b Exclusions and Conditions Seller s obligations with respect to the express war ranties and remedies contained herein are conditioned on the following i Sellers liability and Buyers exclusive remedy is expressly limited to Sellers replacement of the defective gas connector or other goods at Sellers cost excluding labor and freight it being understood such replacement will be made only upon return of the defective item in accordance with Seller s shipping instructions and return authorization and subject to Sellers inspection ii Buyer shall not assign its rights under these express warranties and any attempted assignment shall render such warranties but not any dis ANSI Z223 1 NFPA 54 National Fuel Gas Code Warranty claimers or limitations void and the goods shall be sold AS IS and iii all com mercial gas connectors and other goods shall be carefully inspected for damage by Buyer upon receipt be installed by individuals trained and certified as profes sionals with respect to such installation and be installed used repaired and maintained by Buyer in accordance with local codes or regulations standards set by American National Standard Institute and or American Gas Association Standards The commercial gas
38. fety Quik coupling to complete the connection G Check tightness of all connections Leak test in accordance with accepted testing procedures Rinse H After the installation of the connector carefully push the appliance back to its normal operating position Check that the connection is not kinked over bent or caught under the equipment casters Installation Rights and Wrongs WRONG Avoid sharp bends and kinks when pulling equipment away from wall Maximum pull will kink ends even if installed properly and reduce connector life RIGHT Minimum pull of equipment away from wall permissible for accessibility to Safety Quik Disconnect SHARP BENDS Install metal hose for vertical traverse with a single natural loop Avoid sharp bends that strain and twist the metal hose to a point of early failure at the coupling FATIGUE Maintain the minimum or m bending diam eter between the couplings creates double work fatigue at the fittings Note Appliance must be disconnect ed prior to maximum movement Minimum movement is acceptable to leave connected Nominal connector ID inches 1 2 3 1 1 1 4 Nominal connector ID inches 1 2 3 4 1 1 1 4 Normal Connector ID inches 1 2 3 4 1 1 1 4 NOTE When using 0 2 water column pressure drop capacity can be determined by multiplying the figures above by 0 632 For capacities at conditions other than noted contact yo
39. hread the male nipple I onto the street elbow E and tighten NOTE The quick disconnect MUST BE ORIENTED so that the gas enters the coupling half and exits the nipple half of the quick disconnect Installation personnel MUST follow the flow direction arrows permanently marked on the coupling E Apply thread sealant pipe dope or thread tape to the threads at the appliance end of the gas connector Thread this end of the gas connector into the female threads of the quick disconnect coupling H Tighten Connect quick disconnect female coupling H to the male nipple 1 Check tightness of all connections Leak test in accordance with accepted testing procedures Rinse I After installation of the connector carefully push the appliance back to its normal operating position Check that the connector is not kinked over bent or caught under the equipment casters Double Swivel MAX Appliance Connection Gas Supply Side LC A Follow the Single Swivel MAX installation instructions A B Appliance Side Apply thread sealant pipe dope to the male threads of the gas connector Insert male ends of gas connector into female threads of the Swivel MAX fitting Tighten Apply thread sealant pipe dope to the male threads of the Swivel MAX Insert male threads of SwivelM AX into the quick disconnect coupler female of the SnapFast quick disconnect fitting Tighten with wrench Continue installation following the Single Swiv
40. iente al 1 800 DORMONT 367 6668 Pol tica de Devoluciones No se deben hacer devoluciones a Dormont Manufacturing Company sin obtener primero un n mero de autorizaci n de devoluci n No se aceptar ni acreditar ninguna devoluci n sin esta aprobaci n previa Las devoluciones estar n sujetas a un cargo del 25 por resurtido m s cualquier cargo incurrido por el flete ADVERTENCIA Instrucciones Canadienses de Instalaci n El acople de desconexi n r pida debe instalarse de tal manera que el gas entre por la parte del conector y salga por el empalme Debe seguir las flechas de direcci n del flujo que est n marcadas indeleblemente en el acople 1 La salida del gas debe estar en el mismo cuarto que el aparato de utilizaci n de gas y el conector no debe estar oculto en ni instalado a trav s de una pared piso o divisi n 2 Deben usarse todas las piezas de uni n incluidas con el conector y no debe intentar instalar las tuercas de uni n directamente en el roscado de la tuber a El conector no debe estar acodado torcido o doblado Los conectores deben usarse solamente en sistemas de tuber a que tengan una presi n del gas combustible que no sobrepase 1 2 psi 3 5 kPa 5 Para la instalaci n de aparatos m viles por ejemplo aparatos equipados con ruedas de f brica el doblado o flexi n debe limitarse de acuerdo a las necesidades de sacar y meter el aparato para la limpieza mantenimiento o instalaci n En los aparato
41. instructions on page 8 22 This connector complies with the standard for connectors for moveable gas appliances ANSI Z21 69 CSA 6 16 NO 00 I Ov 1so 9oo1 2008 REGISTERED c Us Dormont Manufacturing Company Export PA 15632 USA INSTALLATION INSTRUCTIONS FIGURE 1 1 Before proceeding CAREFULLY read this full set of instructions including the CAUTION AND WARNINGS section also the a a INSTALLATION RIGHTS AND WRONGS section of this a oe instruction booklet 2 The manual gas shut off ball valve B located in the gas manifold line A must be in the fully closed off position If there is no gas shut off valve in the manifold line the main gas supply line valve not shown must be turned off DO NOT CONTINUE UNLESS THE GAS IS TURNED OFF PI OA 3 Remove the gas connector and contents from the bag or box 4 The location of the two connection end points for the gas appliance connector the gas supply line and the equipment stub out can vary greatly It is not practical to show every possible installation combination These instructions include several examples of common installations The installer must always take great care to ensure that the connector is not kinked twisted or torqued when installed and that the end fittings of the connector are not subjected to sharp bends Please refer to Installation Rights and Wrongs For installations that may result in a sharp bend Dormont Swivel MAX gas connectors a
42. l Connectors for Moveable Gas Appliances ANSI Z21 41 CSA 6 9 Quick Disconnect devices for use with gas fuel CR 92 009 Swivel ANSI Z21 15 CGA 9 1 c us Manually Operated Gas Valve for Appliances Appliance Connector Valves and Hose End Valves Connectors for Moveable Gas Appliances Design certified to ANSI U L 567 Pipe Connectors for Flammable and Combustible Liquids and LP Gas For use with natural gas and a Connectors for use with propane Approvals NSF International Criteria C 2 special equipment On PVC coated models only NSE Component Approved by the Commonwealth of Massachusetts Board of State Examiners of Plumbers Gas Fitters Connector length may not exceed 36 and lever handle valves are not permitted City of New York MEA 274 02 E Compliance CSA B149 1 Natural Gas and Propane Installation Code Warranties and Remedies a Warranty Seller warrants to Buyer that it holds and will pass marketable title to the commercial gas connectors sold hereunder Seller further warrants to Buyer that Seller s commercial gas connector will be free from defects in material and workmanship causing gas leakage during the life of the equipment to which the commercial gas connector is originally connected or installed Limited lifetime warranty Seller warrants to Buyer that the items and components manufactured by Seller other than commercial gas connectors will be free from de
43. mpalme macho K I Figura 2 a D Aplique un sellador de roscado barniz para tuber a o cinta para roscado en el empalme de la v lvula E Enrosque el acople hembra de desconexi n r pida en la rosca del empalme de la v lvula de cierre de gas Apriete con una llave Lado del Aparato E Aplique sellador de roscado barniz para tuber a o cinta para roscado en la salida del aparato F y enrosque el codo en la salida Apriete G Aplique un sellador de roscado barniz para tuber a o cinta para roscado en la rosca macho del codo de rosca macho y hembra Inserte las roscas macho en el acople de rosca hembra x hembra no incluido H Aplique un sellador de roscado barniz para tuber a o cinta para roscado en las roscas del conector de gas Enrosque la manguera en el acople Apriete con una llave I Conecte el empalme macho de desconexi n r pida K en el acople hembra J J Revise el apretado de todas las conexiones Busque fugas de acuerdo a los procedimientos de prueba aceptados K Despu s de la instalaci n del conector empuje con cuidado el aparato de regreso a su posici n normal de operaci n Verifique que el conector no est acodado muy doblado o atrapado bajo las ruedas del equipo 772 704 Instrucciones de Operaci n PARA CONECTAR Empuje el empalme directamente en el acople hasta que la manga caiga hacia delante en el anillo de retenci n Abra la v lvula de cierre para abrir el gas Acople Manga Empalme
44. n anteriormente mencionada podr a no aplicarse a usted Esta garant a le otorga derechos legales espec ficos y usted podr a tener tambi n otros derechos los cuales var an de Estado a Estado Notificaci n y Tiempo de Reclamaci n i El Comprador declara estar de acuerdo en revisar e inspeccionar todos los productos contra la documentaci n de env o y a buscar da os o faltantes al momento de recibir los bienes en su destino ii Cada reclamaci n por p rdida da o en tr nsito u otra causa vis ible a la inspecci n se har con el transportista Las reclamaciones por faltantes deben hacerse en los siguientes cinco 5 d as despu s de la recepci n iii Las partes renuncian expresamente al estatuto de limitaciones y declaran estar de acuerdo que cualquier pro cedimiento legal por cualquier incumplimiento de este contrato ser renunciado a menos que se efect e dentro de los dos 2 a os siguientes al motivo de la acci n 180 9001 2008 REGISTERED 11 INSTALACI N DEL CONJUNTO DE EQUIPO CON M LTIPLE FRONTAL DE ALIMENTACI N DOBLE CUANDO INSTALE UN CONJUNTO DE EQUIPO CON ENTRADA DEGAS DEL M LTIPLE FRONTAL DE ALIMENTACION DOBLE NO UTILICE ACOPLES DE DESCONEXI N R PIDA SAFETY Quix O SnapFast PARA ESTE TIPO DE INSTALACION El uso de un acople de desconexi n r pida en este tipo de instalaci n puede ser peligroso y no se recomienda ADVERTENCIA A menos que las v lvulas de cierre corriente arriba en amb
45. naje conecte la manguera de metal en un lazo vertical No conecte la manguera de metal horizontalmente a menos que sea necesario el auto drenaje luego use un apoyo en el plano inferior Nota Nunca inserte objetos tales como NOTA El Dispositivo de ACIERTO FATIGA Mantener el di metro m nimo o mayor de vuelta entre los acoples crea vueltas dobles provocando fatiga de trabajo en los accesorios Nota El aparato debe estar desconec tado antes de moverlo al m ximo Un movimiento m nimo es aceptable para dejarlo conectado destornilladores sondas etc en la v lvula SnapFast El asiento de la v lvula puede da arse o descentrarse Retenci n es obligatorio en todos los tipos de aparatos m viles de gas CAPACIDAD DEL CONECTOR Capacidad Recta BTU por Hr w 0 64 Sp Gr 1000 BTU por Pie Gas a 0 5 pulg Ca da de Presi n de Columna de Agua Pulgadas D I del conector nominal 2 pies 1 2 150 000 3 4 290 900 1 581 800 347 800 1 1 4 1 075 000 634 000 CAPACIDAD CON EL DISPOSITIVO DE DESCONEXION RAPIDA Pulgadas D I del conector nominal 2 pies 1 2 87 000 3 4 232 000 1 414 000 1 1 4 699 000 CAPACIDAD CON LA VALVULA MANUAL DE CIERRE Pulgadas D I del conector nominal 2 pies 1 2 145 600 3 4 282 400 1 564 800 1 1 4 1 043 600 6 pies 86 600 173 900 4 pies 106 000 215 000 442 700 817 500 6 pies 55 000 139 000 279 000 419 000 4 pies 68 000 180 000 334 0
46. nder the equipment casters 772 704 Operating Instructions TO CONNECT Push nipple straight into coupling until sleeve snaps Coupling Sleeve Nipple forward against retaining ring Open shut off valve to turn on gas TO DISCONNECT Close shut off valve to turn off gas Retract sleeve 1B and pull out nipple IMPORTANT COUPLING IS NOT TO BE USED AS THE 3 PRIMARY SHUT OFF GAS FLOW DIRECTION 4 FIGURE 2 OPTION 2 Sapha QD Device Installed at the Gas Supply This installation method commonly used in Europe shows the quick disconnect coupling attached at the gas supply side The coupling MUST always be on the gas supply side attached to the supply side piping This enables the operator to move the equipment away from the wall in an equipment line up and safely disconnect the gas connector from the gas supply line O House Pipe Inlet Q Appliance Male Stub Out O Full Port Gas Ball Valve Restraining Cable O Safety System Gas Quick Disconnect Coupling Connector female SnapFast Quick GQ Quick Disconnect Nipple GAS FLOW DIRECTION Disconnect Coupling male A 90 Elbow Figure 2 a Restraining Cable Installation Instructions Restraining Cable Installation This Restraining Device Must Always be Reconnected When the Appliance Is in Service The restraining device should be disconnected for movement A Restraining Cable with ARAT E nat vi il ml z i such as servicing or cleaning only after
47. on una ave Lado del Aparato Vea la Figura 1 y 1a C Aplique sellador de roscado barniz para tuber a o cinta para roscado en la salida macho del aparato F Figura 1 y enrosque el codo de rosca macho y hembra E en la salida macho Puede variar mucho la ubicaci n tanto de la salida del equipo como de la T para el m ltiple de la l nea de suministro de gas D Aplique un sellador de roscado barniz para tuber a o cinta para roscado en las roscas macho del codo de rosca macho y hembra E E Separe el empalme de desconexi n r pida macho I Figura 1a del acople J Enrosque el empalme macho 1 en el codo de rosca macho y hembra E y apriete NOTA El acople de desconexi n r pida DEBE ESTAR ORIENTADO de tal manera que el gas entre por la parte del conector y salga por el empalme El personal de instalaci n DEBE seguir las flechas de direcci n del flujo que est n marcadas indeleblemente en el acople E Aplique un sellador de roscado barniz para tuber a o cinta para roscado en las roscas localizadas en el extremo del conector de gas Inserte este extremo del conector de gas en la rosca hembra del acople de desconexi n r pida H Apriete Conecte el acople hembra de desconexi n r pida H en el empalme macho 1 Revise el apretado de todas las conexiones Busque fugas de acuerdo a los procedimientos de prueba acep tados Enjuague I Despu s de la instalaci n del conector empuje con cuidado el aparato de
48. pas de gaz 3 Ne pas couder tordre ou serrer au couple le connecteur 4 Les connecteurs ne doivent tre utilis s qu avec des tuyauteries dont la pression de gaz combustible ne d passe pas 3 5 KPA 0 5 psi 5 Pour l installation d un appareil mobile par exemple les appareils quip s en usine avec des roulettes le pliage et le cintrage doivent se limiter tirer et a pousser l appareil lors du nettoyage de l entretien et du montage Dans le cas d un appareil fixe viter de d placer le connecteur apr s le montage 6 viter tout contact avec une substance ou un corps tranger 7 Installer un robinet de fermeture manuelle accessible a la sortie de la tuyauterie d alimentation de gaz en amont du connecteur 8 Des essais doivent tre effectu s pour v rifier que l ensemble est tanche ATTENTION ne pas utiliser d allumette de bougie de source d inflammation a flamme nue ou autre a cet effet Les solutions pour essai d tanch it peuvent tre l origine de corrosion rincer l eau apr s essai Pour v rifier l tanch it de la tuyauterie d alimentation de gaz voir le National Fuel Gas Code Code national de gaz combustible ANSI Z223 1 ou CAN CGA B149 1 Natural Gas Installation Code Code d installation du gaz naturel et CAN CGA B149 2 Propane Installation Code Code d installation du propane 9 Ce connecteur est conforme aux dispositions de la norme ANSI 7221 69 CSA 6 16 intitul e Connectors for Movabl
49. pply thread sealant pipe dope or thread tape to the appliance s male stub out F and thread street elbow E onto male stub out and tighten with wrenches The location of both the equipment stub out and the tees for the gas supply line manifold can vary greatly D Apply thread sealant pipe dope or thread tape to male street elbow E threads E Separate the quick disconnect coupling male end or nipple 1 from the female end or coupling H Thread the male nipple 1 onto the street elbow E and tighten NOTE The quick disconnect MUST BE ORIENTED so that the gas enters the coupling half and exits the nipple half of the quick disconnect Installation personnel MUST follow the flow direction arrows permanently marked on the coupling Apply thread sealant pipe dope or thread tape to the male threads of the gas connector Thread quick disconnect coupling onto the gas connector threads Tighten Connect quick disconnect female coupling H to the male nipple I Figure 1 a Check tightness of all connections Leak test in accordance with accepted testing procedures After installation of the connector carefully push the appliance back to its normal operating position Check that the connector is not kinked over bent or caught under the equipment casters 11 OPTION 2 Quick Disconnect attached at the gas supply line side Reverse Quick Disconnect Refer to Figure 2 on the next page WARNING If you decide to select an Option
50. re recommended 5 It is recommended that the main gas supply manifold be located 30 42 off the ground There should be pipe tees pointed in the downward direction 6 To facilitate moving equipment as close to the wall as possible the two ends of the Dormont gas connector should be offset to the side from each other 3 offset recommended see drawing 1 7 Each piece of equipment MUST have its own approved manual shut off valve If there is not an accessible manual gas shut off valve for each piece of equipment make sure that the gas has been shut off at the main gas shut off valve for each piece of equipment before continuing 8 MANUAL SHUT OFF VALVE INSTALLATION Female x Female valve ends a If the pipe tee is a male thread Apply thread sealant pipe dope or thread tape to accessible pipe threads located at the gas supply line Thread the gas shut off ball valve onto the male iron pipe and tighten wrench tight Locate ball valve as close as you can to the manifold leaving enough clearance to turn on and off Preferred valve position is vertical see Figure 1 b If the pipe tee is a female thread Apply thread sealant pipe dope or thread tape to the threads of a pipe nipple not supplied preferred length is three inches Thread pipe nipple into female pipe tee off main gas line Then thread the shut off valve onto the pipe nipple and tighten wrench tight 9 WARNING The SnapFast Quick Disconnect coupling D MUST BE oriented
51. regreso a su posici n normal de operaci n Verifique que el conector no est acodado muy doblado o atrapado bajo las ruedas del equipo Conexi n del Aparato con Swivel MAX Doble Lado del Suministro de Gas A Siga las instrucciones de instalaci n del Swivel MAX Sencillo A B Lado del Aparato Aplique un sellador de roscado barniz para tuber a en la rosca macho del conector de gas Inserte el extremo macho del conector de gas en la rosca hembra del accesorio Swivel MAX Apriete Aplique un sellador de roscado barniz para tuber a en la rosca macho del Swivel MAX Inserte la rosca macho del Swivel MAX en el acople de desconexi n r pida hembra del accesorio de desconexi n r pida SnapFast Apriete con una llave Contin e la instalaci n siguiendo las instrucciones de instalaci n del Swivel MAX Sencillo C EyG 1 LO A wJ QW LAZO VERTICAL LAZO HORIZONTAL Pared Suministro de Gas de Nivel Medio Pared Suministro de Gas a Nivel de Piso Equipo Conexi n de Entrada Posterior Alta Equipo Conexi n de Entrada Posterior Baja RECOMENDACI N RECOMENDACI N Instalaci n del Kit Swivel Doble de Dormont Instalaci n del Kit Swivel Sencillo de Modelo 1675KIT2S48 Dormont Modelo 1675KITS48 Instrucciones de Instalacion del Conector del Aparato de Gas Instalaci n de la V lvula de Protecci n de Desconexi n R pida Safety Quik NOTA LA VALVULA DE PROTECCION DE DESCONEXION RAPIDA SAFETY QUIK ES UNA V
52. s de instalaci n fija despu s de la insta laci n debe evitarse el movimiento del conector 6 Se debe evitar el contacto con sustancias u objetos extra os 7 Se debe instalar una v lvula manual de cierre accesible en la salida del sistema de tuber a del suministro de gas corriente arriba del conector 8 El ensamblado final debe ser probado buscando fugas Precauci n No deben usarse cerillos velas flamas abiertas u otras fuentes de ignici n para este prop sito Las soluciones para detecci n de fugas pueden provocar corrosi n enjuague con agua despu s de realizar la prueba Para buscar fugas en el sistema de tuber a de suministro de gas vea el C digo Nacional de Gas Combustible ANS Z223 1 o CAN CGA B149 1 C digo de Instalaci n de Gas Natural y CAN CGA B149 2 C digo de Instalaci n de Gas Propano 9 Este conector cumple con la norma ANSI 221 69 CGA 6 16 de Conectores para aparatos m viles de gas 10 El cable de retenci n DEBE estar conectado siempre que se use el aparato R Capacidad del Conector Capacidad Recta BTU por Hr 0 64 SG Capacidad Recta BTU por Hr 0 64 SG 1 000 BTU por pie con una ca da de 1 000 BTU por pie de gas con una ca da de presi n de columna presi n de columna de agua de 0 5 pulg de agua de 0 5 pulg Conector nominal Conector nominal Di m Int en pulg 2 pies 4 pies 6 pies Di m Int en pulg 2 pies 4 pies 6 pies 1 2 pulg 87 000 68 000 55 000 1 2 pulg 150 000 106 000
53. siga las instrucciones de la p gina 8 22 Este conector cumple con la norma ANSI 721 69 CSA 6 16 para aparatos m viles de gas 1s0 9001 200 REGISTERED cus Dormont Manufacturing Company Export PA 15632 EE UU 2 INSTRUCCIONES DE INSTALACI N FIGURA 1 1 Antes de proceder lea CUIDADOSAMENTE todas estas instruc ciones incluyendo la secci n de PRECAUCIONES Y ADVERTEN CIAS y tambi n la secci n ACIERTOS Y ERRORES EN LA EE INSTALACI N de este folleto de instrucciones 2 La v lvula esf rica manual de cierre B localizada en la l nea del m ltiple A debe estar totalmente cerrada Si no existe una v lvula de cierre en la l nea del m ltiple debe cerrarse la v lvula de la l nea prin cipal de suministro de gas no se muestra NO CONTINUE A MENOS QUE EL GAS ESTE CERRADO 3 Saque el conector de gas y el contenido de la bolsa o caja 4 Puede variar mucho la ubicaci n de los dos puntos de conexi n para el conector de gas del aparato la l nea de sumin istro de gas y la salida del equipo No es pr ctico mostrar todas las combinaciones posibles de la instalaci n Estas instrucciones incluyen varios ejemplos de las instalaciones m s comunes El instalador debe siempre tener mucho cuidado de asegurarse que el conector no est acodado torcido o doblado cuando lo instale y que los accesorios de los extremos del conector no est n sujetos a dobleces muy pronunciados Por favor vea los Aciertos y Errores en la In
54. sition Check that the connection is not kinked over bent or caught under the equipment casters Combination Loop Installation Wall High Level Gas Supply Wall High Level Gas Supply Equipment Rear Low Inlet Connection Equipment Rear High Inlet Connection Recommendation Recommendation Dormont Double Swivel MAX Kit Dormont Safety Quik QD Protection Installation Model 1675KIT2S48 Valve with Double Swivel MAX Fittings Installation Model 1675KITCE2S48 Safety Quik with Single Swivel MAX A Apply thread sealant pipe dope or thread tape to the threads of the gas connector at one end Insert the male threads of the gas connector into the female threads of the Swivel MAX fitting Gas Supply Side B Apply thread sealant pipe dope or thread tape to the male threads of a Swivel MAX fitting Separate the Safety Quik nipple male from the Safety Quik coupling female Thread the male end of the Swivel MAX into the Safety Quik nipple Tighten Appliance Side C Apply thread sealant pipe dope or thread tape to the male stub out of the appliance Thread the street elbow onto the stub out D Apply thread sealant pipe dope or thread tape to the male threads of the street elbow Insert male threads into f x f threaded coupling not included E Apply thread sealant pipe dope or thread tape to the male threads of the gas connector Insert threads into female threaded coupling Tighten E Insert Safety Quik nipple into Sa
55. stalaci n Para las instalaciones que pueden resultar en un doblez muy pronunciado se recomiendan los conectores de gas Swivel MAX de Dormont 5 Se recomienda que el m ltiple del suministro principal de gas est localizado de 76 a 107 cm del suelo Las T de la tuber a deben apuntar hacia abajo 6 Para facilitar el movimiento del equipo tan cerca de la pared como sea posible los dos extremos del conector de gas Dormont deben estar descentrados al lado de cada uno 7 6 cm se recomienda descentrar Vea el Diagrama 1 7 Cada componente del equipo DEBE tener su propia v lvula manual de cierre aprobada Antes de continuar si no hay una v lvula manual de cierre accesible del gas para cada componente del equipo aseg rese que el gas haya sido cerrado en la v lvula principal de cierre de cada componente del equipo 8 INSTALACION DE LA VALVULA MANUAL DE CIERRE Extremos Hembra x Hembra de la v lvula a Si la T de la tuber a tiene rosca macho Aplique un sellador de roscado barniz para tuber a o cinta para roscado en las roscas accesibles de la tuber a localizadas en la l nea de suministro del gas Enrosque la v lvula esf rica de cierre del gas en la tuber a macho de hierro y apriete bien con una llave Coloque la v lvula esf rica tan cerca del m ltiple como pueda dejando espacio suficiente para abrirla y cerrarla Coloque la v lvula preferentemente en forma verti cal vea la Figura 1 b Si la T de la tuber a tiene rosc
56. the length of the gas connector 5 suvelMAK SWIVEL MAX FITTINGS ARE DESIGN CERTIFIED FOR USE WITH DORMONT GAS CONNECTORS ONLY 1 Do not conceal swivel within or run through walls floors or partitions 2 For use on piping systems having fuel gas pressures not exceeding 1 2 psig 3 Install downstream of the gas supply piping manual shut off valve ONLY 4 Use thread sealant pipe dope only when installing a Swivel MAX fitting DO NOT USE TEFLON TAPE ON THE SWIVEL DO NOT OVER TIGHTEN Single Swivel MAX Appliance Connection NOTE The Swivel MAX is attached to the gas supply end of the connector Gas Supply Side A Apply thread sealant pipe dope to the threads at one end of the gas connector Thread this end of the gas connector into the female threads of the Swivel MAX fitting B Apply thread sealant pipe dope to the male Swivel MAX threads Thread this end of the gas connector into the female threads of the gas shut off valve and tighten with wrenches Appliance Side Refer to Figure 1 and 1 a C Apply thread sealant pipe dope or thread tape to the appliance s male stub out F Figure 1 and thread street elbow E onto male stub out The location of both the equipment stub out and the tees for the gas supply line manifold can vary greatly D Apply thread sealant pipe dope or thread tape to male street elbow E threads E Separate the quick disconnect male nipple I Figure 1 a from the coupling J T
57. ur servicing gas supplier NOTE Capacity was determined under test conditions specified by ANSI Z21 69 RIGHT ends causing WRONG Note Never insert such objects as screwdrivers probes etc into the SnapFast valve The valve s seat can be damaged or forced off center 2ft 150 000 290 900 581 800 1 075 000 CAPACITY WITH QUICK DISCONNECT DEVICE 2ft 87 000 232 000 414 000 699 000 CAPACITY WITH MANUAL SHUT OFF VALVE 2 ft 145 600 282 400 564 800 1 043 600 CONNECTOR CAPACITY Straight Length Capacity BTU per Hr w 0 64 Sp Gr 1000 BTU per Cu Ft Gas at 0 5 in Water Column Pressure Drop 4ft 106 000 215 000 442 700 817 500 Aft 68 000 180 000 334 000 541 000 4 ft 102 900 208 700 429 800 793 600 RIGHT TWISTING Couplings and hose should be installed in the same vertical plane Failure to do so causes torsional twisting and undue strain causing premature failure SELF DRAINING In all installations where self draining is not necessary connect metal hose in a vertical loop Do not connect metal hose horizontally unless self draining is necessary then use support on lower plane NOTE Restraining Device is mandatory for all types of moveable gas appliances 6ft 86 600 173 900 347 800 634 000 6ft 55 000 139 000 279 000 419 000 6 ft 84 000 168 800 337 600 615 500 10 Certifications CANADA usa C7 ANSI Z21 69 CSA 6 16 Meta
58. ust be installed so that the gas enters the coupling half and exits the nipple half You must follow the flow direction arrows that are permanently marked on the coupler 1 The gas outlet must be in the same room as the gas fired equipment and the connector must not be concealed within or run through any wall floor or partition 2 All parts of the union supplied with the connector must be used and no attempt shall be made to assemble union nuts directly to pipe threads 3 The connector must not be kinked twisted or torqued 4 Connectors are for use only on piping systems having fuel gas pressures not in excess of 1 2 psi 3 5 kPa 5 For moveable appliance installation e g appliances factory equipped with casters flexing and bending should be limited to the needs of pulling and pushing the appliance in and out for cleaning maintenance or installation For fixed appliance installation connector movement after installation should be avoided 6 Contact with foreign objects or substances must be avoided 7 An accessible manual shutoff valve must be installed at the outlet of the gas supply piping system upstream of the connector 8 The final assembly must be tested for leaks Caution Matches candles open flame or other sources of ignition shall not be used for this purpose Leak test solutions may cause corrosion water rinse after test To check gas supply piping system for leakage see the National Fuel Gas Code ANSI Z223 1 or CAN CGA B1

Download Pdf Manuals

image

Related Search

Related Contents

Refs. 564101 564201  Phoenix Manual.indd  Atención: Este manual contiene medidas de seguridad  Tricity Bendix AW 440 AL User's Manual    MANUEL D`UTILISATION    

Copyright © All rights reserved.
Failed to retrieve file