Home
OPERATOR`S MANUAL MANUEL de L
Contents
1. OPERATOR S MANUAL MANUEL de L UTILISATEUR MANUAL del OPERADOR No de Cat 2267 20 2268 20 Infrared Temp Guns Temp Guns infrarouge Term metros infrarrojos Temp Guns TO REDUCE THE RISK OF INJURY USER MUST READ AND UNDERSTAND OPERATOR S MANUAL AFIN DE R DUIRE LE RISQUE DE BLESSURES L UTILISATEUR DOIT LIRE ET BIEN COMPRENDRE LE MANUEL DE L UTILISATEUR PARA REDUCIR EL RIESGO DE LESIONES EL USUARIO DEBE LEER Y ENTENDER EL MANUAL DEL OPERADOR IMPORTANT SAFETY INSTRUCTIONS WARNING READ ALL SAFETY WARNINGS AND INSTRUCTIONS Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save these instructions This operator s manual contains important safety and operating instructions for the MILWAUKEE Infrared Temp Gun Thermometer Before using the Temp Gun read this operator s manual and all labels on the Temp Gun LASER SAFETY SERVICE eLaser light Do not stare into beam or view directly with optical instruments Do not point laser light at others Laser light can cause eye damage eAvoid exposure to laser radiation Laser may emit hazardous radiation Do not point laser at reflec
2. du sceau du distributeur ou du magasin o le produit a t achet Toute pi ce d fectueuse ou tout composant d fectueux sera remplac sans frais Milwaukee assume tous les frais de transport li s ce processus de garantie Exceptions La garantie ne s applique pas dans les situations suivantes 8 Si le produit a t utilis pour une fin autre que celle indiqu e dans le guide de l utilisateur final ou le manuel d instructions b Si les conditions d utilisations ne sont pas habituelles c Si le produit a t modifi ou r par par une personne non autoris e par TECHTRONIC INDUSTRIES Note Si le cordon lectrique est endommag il doit tre remplac par un centre de r parations agr pour viter les risques d lectrocution CENTRE DE REPARATIONS ET DE SERVICE Rafael Buelna No 1 Col Tezozomoc Mexico Azcapotzalco D F Ph 01 800 832 1949 Mod le Date d achat Sceau du distributeur ou du magasin IMPORTE ET COMMERCIALISE PAR TECHTRONIC INDUSTRIES MEXICO S A DE C V Av Santa Fe 481 piso 6 Col Curz Manca CP 05349 Cuajimalpa D F 13 INSTRUCCIONES IMPORTANTES DE SEGURIDAD ADVERTENCIA LEA TODAS LAS ADVERTENCIAS E INSTRUCCIONES DE SEGURIDAD La inobservancia de las advertencias e instrucciones puede causar una descarga el ctrica un incendio y o lesiones graves Guarde estas instrucciones El manual del operador contiene importantes instrucciones de seguridad y o
3. Service Sales Support Branch or authorized service station nearest you please call 1 800 SAWDUST 1 800 729 3878 Monday Friday 7 00 AM 6 30 PM Central Time or visit our website at www milwaukeetool com Additionally we have a nationwide network of authorized Distributors ready to assist you with yourtool and accessory needs Check your Yellow Pages phone directory under Tools Electric for the names amp addresses of those nearest you or see the Where To Buy section of our website For service information use the Service Center Search icon found in the Parts amp Service section Contact our Corporate After Sales Service Technical Support about Technical Questions Service Repair Questions Warranty call 1 800 SAWDUST fax 1 800 638 9582 email metproductsupport milwaukeetool com Register your tool online at www milwaukeetool com and receive important notifications regarding your purchase ensure that your tool is protected under the warranty become a Heavy Duty club member MEXICO Soporte de CENTRO DE ATENCION A CLIENTES Techtronic Industries Mexico S A de C V Av Presidente Masarik 29 Piso 7 11560 Polanco V Seccion Miguel Hidalgo Distrito Federal M xico 01 800 030 7777 o 55 4160 3540 Lunes a Viernes 9am a 6pm O cont ctanos en www milwaukeetool com mx Para informaci n de Centros de Servicio busca CANADA MILWAUKEE Service MILWAUKEE prides itself in pro
4. teur Consulter le concessionnaire ou un technicien radio TV exp riment pour obtenir de l aide Sp cifications Plage de temp rature de l infrarouge Pour 2267 20 30 C a 400 C 22 F 752 F Pour 2268 20 30 C a 550 C 22 F 1022 F Pr cision de la lecture de l infrarouge Pour 2267 20 30 C 18 C 22 F O F 2 0 C 4 F 0 1 C 1 C 18 C O C 0 F a 32 F 250 6 ix 0 C 400 C 32 F 752 F 2 0 C 4 F ou 2 0 de la lecture selon la plus o id des deux valeurs Pour 2268 20 30 C 18 C 22 F 0 F 2 0 C 4 F 0 1 C 1 C 18 C 10 C 0 F 50 F 2 5 C 5 F 10 C 550 C 50 F 1022 F 1 8 C 4 F ou 1 8 de la lecture selon la plus grande des deux valeurs Assumez la temp rature de fonctionnement ambiante de 23 C 2 C 70 F 77 F R p tabilit 0 8 OU 1 C 2 F selon la plus grande des deux valeurs R solution de l affichage de la temp rature 0 1 C F primaire et secondaire R solution optique 90 de l nergie Pour 2267 20 10 1 Pour 2268 20 12 1 missivit 0 95 Temps de r ponse 500 ms R ponse spectrale 8 14 um Chute 3 m tre Type de laser Classe ll Puissance maximale 1 mW Longueur d onde 630 670 nm Temp rature d utilisation 0 C 50 C 32 F 122 F Temp rature d entreposage 20 C 60 C 4 F 140 F Sans pile Humidit relative
5. 10 85 25 C diminuant lin airement jusqu 10 45 50 C Tension 9 V c c une 1 pile 9 V Autonomie des piles Sup rieure 12 heures pour toutes les fonctions REMARQUE Les 2267 20 et 2268 20 peuvent ne pas r pondre leurs exigences de pr cision de 80 500 MHz 3 V m MONTAGE DE L OUTIL Charge et changement des piles 1 A l aide d un tournevis plat tourner le verrou du compartiment de la pile vers la position d verrouill e et ouvrir la porte du comparti ment de la pile 2 Brancher une 1 pile de 9 V au bloc de con nexion Installer la pile dans le compartiment 3 Fermer la porte du compartiment de la pile Tourner le verrou de la porte de la pile vers la position verrouill e R solution optique 10 1 2267 20 12 1 2268 20 NOTE Un change ment brusque de la tem p rature gt 5 C affecte les lectures de l unit Permettre l unit d atteindre la temp ra ture ambiante avant de l utiliser 5 30 minutes selon le changement de temp rature Affichage de la temp rature en Celsius ou en Fahrenheit Pour r gler l chelle de la temp rature tirer la g chette et appuyer sur le bouton R GLAGE SET trois fois Appuyer sur les boutons au dessus des fleches Haut et Bas pour basculer entre C et F Attendre 5 secondes pour enregistrer le r glage et quitter R glage du verrou du laser Pour activer et d sactiver le laser tirer la
6. C 0 F to 32 F 2 5 C 5 F 0 C to 400 C 32 F to 752 F 2 0 C 4 F or 2 0 of reading whichever is greater For 2268 20 30 C to 18 C 22 F to 0 F 2 0 C 4 F 0 1 C 1 C 18 C to 10 C OF to 50 F 25 C 5 FP 10 C to 550 C 50 F to 1022 F 1 8 C 4 F or 1 8 of reading whichever is greater Assume ambient operating temperature of 23 C 2 C 7O F to 77 F Repeatability 0 8 OR 1 C 2 F whichever is greater Temperature display resolution 0 1 C F in Primary and Secondary Distance to spot 9096 energy For 2267 20 10 to 1 For 2268 20 12 to 1 Emissivity 0 95 Response time 500 msec Spectral response 8 to 14um Drop 3 meters Laser Type Class Il Max Power 1mW Wavelength 630 670 nm Operating temperature 0 c to 50 C 32 Storage temperature 20 C to 60 C 4 without battery Relative humidity 10 to 85 at 25 C decreasing linearly to 10 to 45 at 50 C Voltage 9 DC one 1 9V battery Battery life Greater than 12 hrs with all functions o to 122 F F F to 140 F NOTE 2267 20 and 2268 20 may not meet its stated accuracy when exposed to 80 500MHz at 3V m ASSEMBLY Loading Changing the Battery 1 Using a flat screwdriver rotate the battery door lock to the unlocked position and open the battery door 2 Connect one 1 9V battery to the connector block Fit the battery into the compartment 3 Close the battery door Turn the bat
7. de fonction pour basculer entre les temp ratures Attendre 5 secondes pour enreg istrer les plages et quitter Pile faible Lorsque l ic ne Piles faibles s affiche changer la pile 90 5 2 B3 Mode Description MAX Affiche la temp rature maximale mesur e pendant une lecture continue MIN Affiche la temp rature minimale mesur e pendant une lecture continue AVG Affiche la temp rature moyenne des 20 derni res mesures pendant une lecture continue DIF Affiche la diff rence entre MAX et MIN pendant une lecture continue 11 ENTRETIEN ACCESOIRES GARANTIE LIMIT E AUX TATS UNIS ET AU CANADA A AVERTISSEMENT Pour r duire le risque de blessures toujours retirer les piles de l outil avant d en assurer l entretien Ne jamais d monter l outil Pour toute r para tion communiquer avec un centre de service MILWAUKEE Entretien de l outil Garder l outil en bon tat en le soumettant un programme d entretien r gulier Apr s six mois selon l utilisation confier l outil un centre de service MILWAUKEE Si l outil ne d marre pas ou ne fonctionne pas plein r gime une fois les piles compl tement charg es nettoyer les contacts du compartiment des piles Si l outil ne fonctionne toujours pas correctement le confier un centre de service MILWAUKEE afin de le faire r parer Nettoyage de la lentille Enlever les particules libres au moyen d un jet d air c
8. de l alarme 14 Indicateur de temp rature C ou F 15 Mesure principale 16 Mesure secondaire 17 Indicateur de mode FC Federal Communications Commission AVERTISSEMENT Les changements ou les modifi cations apport s cette unit non express ment ap prouv s par l organisme responsable de la conformit peuvent annuler l autorit de l utilisateur utiliser cet quipement Cet quipement a t test et d clar conforme aux limites des dispositifs num riques de classe B en vertu de la section 15 des r glementations de la FCC Ces limites ont pour but de fournir une protection raison nable contre les interf rences nuisibles dans le cadre d une installation r sidentielle Cet quipement g nere utilise et peut mettre de l nergie de radiofr quence Il est donc recommand de l installer et de l utiliser conform ment aux instructions afin d viter toute interf rence nuisible aux communications radio Cependant il n existe aucune garantie selon laquelle des interf rences ne se produiront pas dans le cas d une installation sp cifique Si cet appareil provoque des interf rences nuisibles pour les r ceptions radio et t l vis es ce qui peut tre d termin en l teignant puis en le rallumant il est conseill d y rem dier en suivant l une ou plusieurs des mesures suivantes R orienter ou repositionner l antenne r ceptrice Augmenter l espace entre l quipement et le r cep
9. flush with water If liquid contacts eyes additionally seek medical help Liquid ejected from the battery may cause irritation or burns Have your Temp Gun serviced by a qualified repair person using only identical replacement parts This will ensure that the safety of the tool is maintained Do not disassemble Incorrect reassembly may result in the risk of electric shock or fire If it is dam aged take it to a MILWAUKEE service facility eStore in a cool dry place Do not store where temperatures may exceed 140 F 60 C such as in direct sunlight a vehicle or metal building during the summer Do not remove or deface labels Maintain labels and nameplates These carry important information If unreadable or missing contact a MILWAUKEE service facility for a free replace ment FC Federal Communications Commission WARNING Changes or modifications to this unit not ex pressly approved by the party responsible for compliance could void the user s authority to operate the equipment This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not in stalled and used in accordance with the instructions may cause harmful interfer
10. lectrique ou d incendie En cas de dommage confier le produit un centre de service MILWAUKEE eEntreposer le produit dans un endroit frais et sec Ne pas l entreposer dans des endroits ou la temp rature peut d passer 60 C 140 F par exemple un endroit expos directement la lumi re du soleil un v hicule ou une construction en m tal pendant l t eNe pas retirer ou endommager les tiquettes Maintenir en tat les tiquettes et les plaques signal tiques Des informations importantes y figurent Si elles sont illisibles ou manquantes contacter un centre de services et d entretien MILWAUKEE pour un remplacement gratuit PICTOGRAPHIE Volts Courant continu ATTENTION Lampe laser Ne pas fixer le faisceau Produit laser viter l exposition Le rayonnment laser est mis de cette ouverture Afin de r duire le risque de bles sures l utilisateur doit lire le manuel de l utilisateur Q gt DESCRIPTION FONCTIONNELLE 1 Fen tre du laser 2 Plaque signal tique de 2267 20 3 Plaque signal tique de 2268 20 4 G chette 5 Afficheur 6 Boutons Mode R glage Y Alarme 7 Verrou de la porte du compartiment des piles 8 Porte du compartiment des piles 9 Indicateur de pile SA 10 Indicateur de retenue T 11 Indicateur d activation a FR du laser Has 12 Indicateur de verrouillage de la g chette 13 Indicateur
11. m xima m nima promedio o diferencial 3 Suelte el gatillo Se muestra HOLD retenci n hasta que la pantalla se apaga en aproximada mente siete segundos NOTA Un cambio r pido en la temperatura gt 5 C afecta las lecturas de la unidad Deje que la unidad alcance la temperatura ambiente antes de usarla 5 a 30 minutos dependiendo del cambio de temperatura objeto Modo Descripci n MAX Muestra la temperatura m xima medida durante una lectura continua MIN Muestra la temperatura m nima medida durante una lectura continua AVG Muestra la temperatura promedio de las ltimas 20 mediciones durante una lectura continua DIF Muestra la diferencia entre MAX y MIN durante una lectura continua 16 Configuraci n del seguro del gatillo Para encender y apagar el seguro del gatillo jale el gatillo y luego oprima el bot n SET configurar cinco veces Presione los botones que se encuen tran sobre las flechas ascendente y descendente para cambiar entre ENCENDIDO y APAGADO Espere 5 segundos para que se guarde la configuraci n y salga A F Len CL uU MAX e 83 A 2 55 Hi A Je LU Bateria baja U ba Cuando se muestre el cono de max A bater a baja cambie la bater a 1 3 MANTENIMIENTO Alarma de temperatura Presione el bot n de alarma para encender la funci n alarma Se muestra el cono de la campana Si la lectura de la temperatura est fuera del rango pree
12. AD Se garantiza al comprador original que los productos de pruebas y mediciones MILWAUKEE que incluyen la herramienta la s bater a s de iones de litio y el cargador de bater as excepto las bater as alcalinas no presentan defectos de material ni de mano de obra Sujeto a ciertas excepciones MILWAUKEE reparar o reemplazar cualquier pieza de este producto que despu s de ser examinada MILWAUKEE determine que es defectuosa por material o mano de obra durante un per odo de cinco 5 afios despu s de la fecha de compra Env e la herramienta de pruebas y mediciones y una copia del comprobante de la compra al centro de servicio m s cercano de f brica de MILWAUKEE Electric Tool Corporation Esta garant a no se aplica a los da os que MILWAUKEE determine son consecuencia de reparaciones realizadas o intentos de reparaciones por parte de personal no autor izado por MILWAUKEE uso indebido alteraciones abuso desgaste y deterioro normales falta de mantenimiento o accidentes El per odo de garant a para la bater a de IONES DE LITIO que viene con la herramienta de pruebas y mediciones es de dos 2 a os a partir de la fecha de compra La bater a alcalina que viene con la herramienta de pruebas y mediciones tiene una garant a por separado otorgada por el fabricante de la bater a El per odo de garant a para un DETECTOR DE VOLTAJE SIN CONTACTO 2201 20 es de un 1 a o a partir de la fecha de compra No se necesita registro de garan
13. LY TO YOU THIS WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES WRITTEN OR ORAL TO THE EXTENT PERMITTED BY LAW MILWAUKEE DISCLAIMS ANY IMPLIED WARRANTIES INCLUDING WITHOUT LIMITA TION ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE OR PURPOSE TO THE EXTENT SUCH DISCLAIMER IS NOT PERMITTED BY LAW SUCH IMPLIED WARRANTIES ARE LIMITED TO THE DURATION OF THEAPPLICABLE EXPRESS WARRANTY AS DESCRIBED ABOVE SOME STATES DO NOT ALLOW LIMI TATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE This warranty applies to product sold in the U S A and Canada only LIMITED WARRANTY MEXICO CENTRAL AMERICA AND CARIBBEAN TECHTRONIC INDUSTRIES warranty is for 5 year since the original purchase date This warranty card covers any defect in material and work manship on this Power Tool To make this warranty valid present this warranty card sealed stamped by the distributor or store where you pur chased the product to the Authorized Service Center ASC Or if this card has not been sealed stamped present the original proof of purchase to the ASC Call toll free 1 800 832 1949 to find the nearest ASC for ser vice parts accessories or components Procedure to make this warranty valid Take the product to the ASC along with the warranty card s
14. PRESA APLICABLE SEG N SE DESCRIBE ANTERIORMENTE ALGUNOS ESTADOS NO PERMITEN LIMITACIONES EN LA DURACI N DE UNA GARANT A IMPL CITA POR LO TANTO LA LIMITACI N ANTERIOR PUEDE NO APLICARSE PARA USTED ESTA GARANT A LE OTORGA DERECHOS LEGALES ESPEC FICOS Y TAMBI N PUEDE TENER OTROS DERECHOS QUE VAR AN DE ESTADO EN ESTADO Esta garant a se aplica a los productos vendidos en los EE UU y Canad P LIZA DE GARANT A VALIDA SOLO PARA M XICO AM RICA CENTRAL Y EL CARIBE TECHTRONIC INDUSTRIES garantiza por 5 afios este producto a partir de la fecha original de compra Esta garant a cubre cualquier defecto que presenten las piezas componentes y la mano de obra contenidas en este producto Para Am rica Central y el Caribe se debe confirmar en el Centro de Servicio Autorizado el plazo de la garant a Para hacer efectiva la Garant a deber presentar al Centro de Servicio Autorizado la P liza de Garant a sellada por el establec imiento en donde adquiri el producto Si no la tienen podr presentar el comprobante de compra original Usted puede llamar sin costo al tel fono 01 800 832 1949 o por correo electr nico a la direcci n servicio ttigroupna com para ubicar el Centro de Servicio Autorizado m s cercano a su domicilio en el cual adem s podr adquirir partes componentes consumibles y accesorios que usted necesite Procedimiento para hacer v lida la garant a Acuda al Centro de Servicio con el producto y la
15. RANTIES IMPLICITES EST LIMIT E LA P RIODE APPLICABLE DE LA GARANTIE EXPRESSE TEL QUE CELA EST D CRIT PR C DEMMENT CERTAINS TATS ET PROVINCES NE PERMETTANT PAS DE LIMITATION DE DUR E DES GARANTIES IMPLICITES LES RESTRICTIONS CIDESSUS PEUVENT NE PAS TRE APPLICABLES LA PRESENTE CONFERE L UTILISATEUR DES DROITS L GAUX PARTICULIERS IL B N FICIE GALEMENT D AUTRES DROITS QUI VARIENT D UN TAT L AUTRE Cette garantie s applique aux produits vendus aux tats Unis et au Canada uniquement GARANTIE LIMIT E MEXIQUE AMERIQUE CENTRALE ET CARA BES TECHTRONIC INDUSTRIES garantit le produit pendant cinq ans partir de la date d achat d origine Le pr sent bon de garantie couvre tous les vices de mat riau et de fabrication que peut afficher cet outil lectrique Pour assurer la validit de la pr sente garantie veuillez pr senter le bon de commande estampill du sceau du distributeur ou du magasin o le produit a t achet au centre de r parations agr Si le bon de commande n a pas t estampill veuillez fournir la preuve d achat d origine au centre de r parations agr Pour un entretien des pi ces des accessoires ou d autres composants composer sans frais le 1 800 832 1949 afin d obtenir les coordonn es du centre de r parations agr le plus pr s Proc dure pour assurer la validit de la garantie Pr senter le produit au centre de r parations agr accompagn du bon de commande estampill
16. Si el producto est da ado ll velo a una instalaci n de servicio MILWAUKEE eAlmacene el producto en un lugar limpio y seco No lo guarde en lugares donde la tempera tura supere los 60 C 140 F como por ejemplo bajo la luz solar directa en un veh culo o en un edificio met lico durante el verano No retire ni deteriore las etiquetas Mantenga las etiquetas y las placas de identificaci n Es tas contienen informaci n importante Si es ilegible o faltante comun quese con una instalaci n de servicio MILWAUKEE para solicitar un reemplazo gratuito Federal Communications Commission FC ADVERTENCIA Los cambios o modificaciones hechos a esta unidad sin la autorizaci n expresa del re sponsable del cumplimiento de la norma podr an anular la autoridad del usuario para manejar el equipo Se ha verificado y determinado que este equipo cumple con los l mites correspondientes a los dispositivos digitales de Clase B de acuerdo con la Parte 15 de las Normas de la FCC Estos l mites se han dise ado para garantizar una protecci n razonable contra interferencias perjudiciales en instalaciones residenciales Este equipo genera utiliza y puede radiar energ a de radiofrecuencia y si no se instala y utiliza en conformidad con las instrucciones puede gen erar interferencia perjudicial para la radiocomunicaci n No obstante no se garantiza que no se produzca inter ferencia en una instalaci n concreta Si este equipo en efe
17. a espectral entre 8 y 14 um Ca da 3 metros Tipo de l ser Clase II Potencia m x 1 mW Longitud de onda 630 670 nm Temperatura de funcionamiento entre O C y 50 C entre 32 F y 122 F Temperatura de almacenamiento entre 20 C y 60 C entre 4 F y 140 F sin bater as Humedad relativa 10 a 85 a 25 C disminuyendo linealmente hasta 10 a 45 a 50 C Voltaje 9 V corr cont uno 1 bater a 9 V Vida til de la bater a M s de 12 h con todas las funciones NOTA El 2267 20 y 2268 20 pueden no cumplir con su precisi n nominal dentro de 80 500MHz a 3V m SIMBOLOG A Volts Corriente alterna PRECAUCI N L ser No mire fijamente el rayo l ser Producto l ser Evite la exposici n La radiaci n l ser se emite a trav s de esta abertura Para reducir el riesgo de lesiones el usuario debe leer y entender el manual del operador Qe lt DESCRIPCI N FUNCIONAL 1 Ventana del l ser 2 Placa de identificaci n de 2267 20 3 Placa de identificaci n de 2268 20 4 Gatillo 5 Pantalla 6 Botones de modo con figuraci n alarma T Traba de la puerta de las bater as 8 Puerta de las bater as 9 Indicador de bater a 10 Indicador de retenci n 11 Indicador de l ser activo 12 Indicador de seguro de gatillo 13 Indicador de alarma 14 Indicador de C o F 15 Medici n primaria 16 Medici n secundaria 17 Indicado
18. cto genera interferencia perjudicial para la recepci n de radio o televisi n que se puede determinar apagando y encendiendo el equipo se insta al usuario a intentar corregir la interferencia tomando una o varias de las siguientes medidas Reorientar o reubicar la antena receptora Aumentar la distancia que separa al equipo del receptor eSolicitar ayuda al distribuidor o a un t cnico de radio y televisi n experto Especificaciones Rango de temperatura IR Para 2267 20 entre 30 C y 400 C entre 22 F y 752 F Para 2268 20 entre 30 C y 550 C entre 22 F y 1022 F Precisi n IR Para 2267 20 entre 30 C y 18 C entre 22 F y 0 F 2 0 C 4 F FOI CIA C entre 18 C y 0 C entre 0 F y 32 F 2 5 C 5 F entre 0 C y 400 C 32 F to 752 F 2 0 C 4 F o 2 0 de la lectura la que sea mayor Para 2268 20 entre 30 C y 18 C entre 22 F y O F 2 0 C 4 F 0 1 C 1 C entre 18 C y 10 C entre 0 F y 50 F 2 5 C 5 F entre 10 C y 550 C 50 F to 1022 F 1 8 C 4 F o 1 8 de la lectura la que sea mayor Asuma la temperatura de funcionamiento ambiente de 23 C 2 C 70 F a 77 F Repetibilidad 0 8 O 1 C 2 F la que sea mayor Resoluci n de pantalla de temperatura 0 1 C F primaria y secundaria Distancia al objetivo 90 de energ a Para 2267 20 entre 10 y 1 Para 2267 20 entre 12 y 1 Emisividad 0 95 Tiempo de respuesta 500 ms Respuest
19. de gasoline turpentine lacquer thinner paint thinner chlorinated cleaning solvents ammonia and house hold detergents containing ammonia Never use flammable or combustible solvents around tools Repairs For repairs return the tool to the nearest service center listed on the back cover of this operator s manual A WARNING Always remove batteries before changing or removing accessories Only use accessories specifically recommend ed for this tool Others may be hazardous For a complete listing of accessories refer to your MILWAUKEE Electric Tool catalog or go online to www milwaukeetool com To obtain a catalog con tact your local distributor or a service center LIMITED WARRANTY USA AND CANADA MILWAUKEE Test amp Measurement Products includ ing bare tool li ion battery pack s and battery char ger but excluding alkaline batteries are warranted to the original purchaser only to be free from defects in material and workmanship Subject to certain exceptions MILWAUKEE will repair or replace any part on this product which after examination is deter mined by MILWAUKEE to be defective in material or workmanship for a period of five 5 years after the date of purchase Return the Test amp Measurement tool and a copy of proof of purchase to the nearest Milwaukee Electric Tool Corporation factory Service Center This warranty does not apply to damage that MILWAUKEE determines to be from repairs made or a
20. ducing a premium quality product that is NoTHING Bur Heavy Duty Your satisfaction with our products is very important to us If you encounter any problems with the operation of this tool or you would like to locate the factory Service Sales Support Branch or authorized service station nearest you please call 1 800 268 4015 Monday Friday 7 00 4 30 CST fax 866 285 9049 Milwaukee Tool Canada Ltd Additionally we have a nationwide network of authorized Distributors ready to assist you with your tool and accessory needs Call 1 800 268 4015 to find the names and addresses of the closest retailers or consult Where to buy on our website www milwaukeetool ca MILWAUKEE est fier de proposer un produit de premi re qualit NoTHING But Heavy Durv Votre satisfaction est ce qui compte le plus En cas de probl mes d utilisation de l outil ou pour localiser le centre de service ventes ou le centre d entretien le plus proche appelez le 1 800 268 4015 Lundi Vendredi 7 00 4 30 CST fax 866 285 9049 Milwaukee Tool Canada Ltd Notre r seau national de distributeurs agr s se tient votre disposition pour fournir l aide technique l outillage et les accessoires n cessaires Composez le 1 800 268 4015 pour obtenir les noms et adresses des revendeurs les plus proches ou bien consultez la section Ou acheter sur notre site web l adresse www milwaukeetool ca Servicio MILWAUKEE Contacta nuestro s
21. ealed stamped by the distributor or store where you pur chased the product and there any faulty piece or component will be replaced without cost for you We will cover all freight costs relative with this warranty process Exceptions This warranty is not valid in the following situations a When the product is used in a different manners from the end user guide or instruction manual b When the conditions of use are not normal c When the product was modified or repaired by people not authorized by TECHTRONIC INDUSTRIES Note If cord set is damaged it should be replaced by an Authorized Service Center to avoid electric risks SERVICE AND ATTENTION CENTER Rafael Buelna No 1 Col Tezozomoc Mexico Azcapotzalco D F Ph 01 800 832 1949 IMPORTED AND COMMERCIALIZED BY TECHTRONIC INDUSTRIES MEXICO S A DE C V Av Santa Fe 481 piso 6 Col Curz Manca CP 05349 Cuajimalpa D F Model Date of Purchase Distributor or Store Stamp REGLES IMPORTANTES DE S CURITE incendie ou des blessures graves trouvant sur le thermom tre Temp Gun AVERTISSEMENT LIRE TOUTES LES R GLES ET INSTRUCTIONS DE S CURIT Ne pas suivre l ensemble des r gles et instructions peut entrainer une lectrocution un Conserver ces instructions Ce manuel d utilisation contient des instructions importantes de s curit et de fonctionnement concernant le thermometre infrarouge Temp Guns de Avant d utiliser le Te
22. ence to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television recep tion which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Consult the dealer or an experienced radio TV techni cian for help 1 Laser window 2 2267 20 nameplate 3 2268 20 nameplate 4 Trigger 5 Display 6 Mode Set Alarm Buttons 7 Battery door lock 8 Battery door 9 Battery indicator 10 Hold indicator 11 Laser active indicator 12 Trigger lock indicator 13 Alarm indicator 14 C or F indicator 15 Primary measurement 16 Secondary measurement 17 Mode indicator SYMBOLOGY V Volts Direct Current CAUTION Laser Light Do Not Stare Into Beam Laser product Avoid Exposure Laser Radiation Is Emitted From This Aperture To reduce the risk of injury user must read operator s manual Specifications IR Temperature range For 2267 20 30 C to 400 C 22 F to 752 F For 2268 20 30 C to 550 C 22 F to 1022 F IR Accuracy For 2267 20 30 C to 18 C 22 F to 0 F 2 0 C 4 F 0 1 C 1 C 18 C to 0
23. endente y descendente para cambiar entre ENCENDIDO y APAGADO Espere 5 segundos para que se guarde la configuraci n y salga Centro del objetivo Puntero l ser aprox 19 mm 3 4 sobre el centro del objetivo Tama o del objetivo a la distancia indicada 2267 20 y 2268 20 A una distancia de 305 mm 1 el objetivo tiene un di metro de 38 mm 1 5 2267 20 A una distancia de 915 mm 3 el objetivo tiene un di metro de 91 4 mm 3 6 2268 20 A una distancia de 915 mm 3 el objetivo tiene un di metro de 76 mm 3 2267 20 A una distancia de 152 cm 5 el objetivo tiene un di metro de 152 mm 6 2268 20 A una distancia de 152 cm 5 el objetivo tiene un di metro de 127 mm 5 OPERACION Escaneado de la temperatura de un objeto 1 Tire del gatillo y no lo suelte A A durante al menos 2 segundos F Len DE LE AT y escanee la temperatura de superficie de un objeto Se utiliza un puntero de l ser para apuntar en la zona que se est Max a escaneando e Ba NOTA El objeto debe ser m s a grande que el objetivo que se HOLD est escaneando De lo con i z trario las lecturas pueden verse n afectadas Consulte la secci n LS Distancia al objetivo para con E e B3 ocer el tama o necesario del 2 Al seguir oprimiendo el gatillo el cono A se muestra junto con las lecturas de la medida principal temperatura de la superficie y la me dida secundaria temperatura
24. ervicio t cnico para Preguntas T cnicas Asesor a servicio y reparaci n Garant a Adicionalmente tenemos una red nacional de distribuidores autorizados listos para ayudarle con su herramienta y sus accesorios Por favor llame al 01 800 030 7777 o env e correo a servicio tecnico milwaukeetool com para obtener los nombres y direcciones de los m s cercanos a el icono Servicio al cliente Cont ctanos es usted o consulte la secci n D nde Comprar en nuestro sitio web www milwaukeetool com mx MILWAUKEE TOOL 13135 West Lisbon Road Brookfield Wisconsin U S A 53005 58 14 2267d1 06 15 Printed in China 07804900101Q 01 A
25. fluence de l alcool de drogues ou de m dicaments Un moment d inattention pendant l utilisation de ce produit peut r sulter en une blessure grave Ne pas travailler hors de port e Se tenir bien camp et en quilibre en tout temps Cela permet un meilleur contr le en cas d impr vus UTILISATION ET ENTRETIEN DE LA BATTERIE Cet outil fonctionne avec une 1 pile de 9 V qui doit tre install e correctement dans le thermometre Temp Gun de MILWAUKEE Ne pas tenter d utiliser cet outil avec une autre tension ou avec un autre type d alimentation Ne pas laisser la pile la port e des enfants Installer la pile en respectant la polarit et indiqu e Se d barrasser imm diatement des piles us es eNe pas br ler ou d monter les piles eEviter tout contact avec le liquide pouvant tre ject de la pile en cas de manutention abusive En cas de contact accidentel rincer abondamment avec de l eau Si le liquide entre en contact avec les yeux consulter un m de cin L lectrolyte qui s chappe de la pile peut causer des d mangeaisons ou des br lures ENTRETIEN eConfier la r paration du thermom tre Temp Gun un r parateur qualifi qui utilise des pi ces de rechange identiques aux pi ces d origine ce qui pr servera la s ret de l outil Ne pas d sassembler le produit Un remon tage inappropri peut r sulter en un risque de d charge
26. g chette et appuyer sur le bouton R GLAGE SET qua tre fois Appuyer sur les boutons au dessus des fleches Haut et Bas pour basculer entre Marche et Arr t Attendre 5 secondes pour enregistrer le r glage et quitter Centre du point Pointeur laser environ 19 mm 3 4 au dessus du O centre du point Taille du point la distance indiqu e 2267 20 et 2268 20 une distance de 305 mm 19 le diam tre du point est de 38 mm 1 5 2267 20 une distance de 915 mm 3 le diam tre du point est de 91 4 mm 3 6 2268 20 une distance de 915 mm 3 le diam tre du point est de 76 mm 3 2267 20 une distance de 152 cm 5 le diam tre du point est de 152 mm 6 2268 20 une distance de 152 cm 5 le diam tre du point est de 127 mm 5 10 2 Pendant que l utilisateur con OPERATION Balayage de la temp rature de l objet 1 Tirer sur la g chette et la tenir en place pendant au moins deux secondes et saisir la MR de surface de l objet Un pointeur laser est utilis pour viserla zone balay e 1 n NOTE L objet doit tre plus grand que la zone balay e Si tel n est pas le cas les lectures peu e 3 vent tre affect es Consulter la section Resolution optique pour connaitre les dimensions requises de l objet HOLD F Len il As MAX e B3 tinue de tenir la g chette l ic ne s affiche avec la lecture de la mesure
27. l be fl m affected See Distance To Spot M for necessary object size c e B3 2 As you continue to hold the trigger the icon A is displayed a along with the primary measure De dna So ment surface temperature and n secondary measurement maxi T mum minimum average or dif max si ferential temperature readings e B3 3 Release the trigger HOLD is displayed until the screen shuts off in about ten seconds Setting the Trigger Lock To turn the trigger lock on and off pull the trigger and then press the SET button five times Press the buttons above the up and down arrows to toggle between ON and OFF Wait 5 seconds for the set ting to save and exit Temperature Alarm E Press the ALARM button to turn on the alarm function The bell icon is F displayed If the temperature read OR n ing is outside the preset range the temperature reading will flash Setting Preset Range for the A Alarm ip 1 To set the alarm range pull the trigger and then press the SET a button Repeat to toggle between HI and LO settings 2 Press the up or down arrow soft keys to toggle between tem peratures Wait 5 seconds for the ranges to save and exit Low Battery When the Low Battery icon is dis ES played change the battery 4 a t iT 2 B3 Mode Description MAX Displays maximum temperature measured during a continuous reading MIN Displays minimum temperature measured during a conti
28. lcohol o alg n medicamento Un momento de descuido puede causar lesiones personales graves No estire el cuerpo para alcanzar mayor dis tancia Mantenga los pies bien asentados y conserve el equilibrio en todo momento Esto permite tener un mejor control en situaciones inesperadas USO Y CUIDADO DE LAS HERRAMIENTAS CON BATERIA Esta herramienta est dise ada para alimentarse con 1 bater a de 9V debidamente insertada en el term metro Temp Gun de MILWAUKEE No intente utilizarlo con otro voltaje o fuente de alimentaci n No deje la bater a al alcance de los nifios Instale la bater a seg n los diagramas de polaridad 14 Deseche de inmediato las bater as usadas en forma correcta No incinere ni desarme las bater as En condiciones abusivas puede salir l quido expulsado de la bater a evite el contacto Si se produce un contacto accidental l vese con agua Si el l quido entra en contacto con los ojos adem s busque atenci n m dica El l quido que sale expulsado de la bater a puede provocar irritaciones o quemaduras MANTENIMIENTO Haga que un t cnico calificado realice el mantenimiento de su Temp Gun utilizando solamente piezas de repuesto id nticas Esto asegurar que se mantenga la seguridad de la herramienta No desarme el producto Si se vuelve a armar de manera incorrecta puede causar un riesgo de descarga el ctrica o de incendio
29. mp Gun lire le pr sent manuel d utilisation ainsi que toutes les tiquettes se S CURIT RELATIVES AU LASER eLampe laser Ne pas fixer directement le faisceau ou l examiner directement au moyen d instruments d optique Ne pas diriger la lam pe laser vers les autres personnes La lampe laser peut provoquer des l sions oculaires Eviter de s exposer au rayonnement laser Cela peut s av rer dangereux Ne pas diriger le laser vers des surfaces r fl chissantes Cela peut entrainer des con s quences impr visibles S CURIT DU LIEU DE TRAVAIL Tenir les enfants et les curieux l cart au mo ment d utiliser le thermom tre Temp Gun S il n est pas utilis ranger le thermom tre Temp Gun hors de port e des enfants et interdire quiconque de l utiliser si la personne ne connait pas bien le produit ou ces instructions Eviter les environnements dangereux Ne pas exposer l unit la pluie ou la neige et ne pas l utiliser dans un endroit humide ou mouill Ne pas utiliser l unit dans un endroit propice aux explo sions fum es gazeuses poussi res ou mat riaux inflammables l insertion ou le retrait du bloc piles pouvant cr er des tincelles un incendie pourrait alors clater S CURIT INDIVIDUELLE Rester vigilant se concentrer sur son travail et faire preuve de bon sens au moment d utiliser le thermom tre Temp Gun Ne pas utiliser cet appareil en cas de fatigue ou sous l in
30. nuous reading AVG Displays average temperature of last 20 measurements during a continuous reading DIF Displays the difference between MAX and MIN during a continuous reading MAINTENANCE ACCESSORIES A WARNING To reduce the risk of injury always remove the batteries from the tool before performing any maintenance Never disassemble the tool Contact a MILWAUKEE service facility for ALL repairs Maintaining Tool Keep your tool in good repair by adopting a regular maintenance program After six months to one year depending on use return the tool to a MILWAUKEE service facility for repairs If the tool does not start or operate at full power with new batteries clean the contacts on the bat tery door If the tool still does not work properly return the tool to a MILWAUKEE service facility for repairs Cleaning the Lens Blow off loose particles with clean compressed air Carefully wipe the suface with a cotton swab moistened with water Using a second cotton swab dry completely A WARNING To reduce the risk of per sonal injury and damage never immerse your tool in liquid or allow a liquid to flow inside it Cleaning Clean dust and debris from tool Keep tool handles clean dry and free of oil or grease Use only mild soap and a damp cloth to clean the tool since certain cleaning agents and solvents are harmful to plastics and other insulated parts Some of these inclu
31. omprim Nettoyer la surface avec pr caution au moyen d un coton tige humect l eau A AVERTISSEMENT Pour minimiser les risques de blessures ou de dommages l outil n immergez jamais l outil la batterie ou le chargeur et ne laissez pas de liquide s y infiltrer Nettoyage Nettoyer les vents de l outil des d bris et de la poussi re Garder les poign es de l outil propres s ches et exemptes d huile ou de graisse Utiliser uniquement un savon doux et un linge humide puisque certains agents de nettoyage et certains solvants peuvent d t riorer le plastique et les autres pieces isol es En voici des exemples l essence la t r benthine les diluants laque ou peinture les solvants chlor s l ammoniaque et les d tergents usage domestique qui en contien nent Ne jamais utiliser de solvants inflammables ou combustibles autour des outils R parations Pour toute r paration confier l outil au centre de service le plus pr s indiqu au dos du pr sent manuel d utilisation 12 A AVERTISSEMENT Retirez toujours la batterie avant de changer ou d enlever les accessoires L utilisation d autres accessoires que ceux qui sont sp cifiquement recomman d s pour cet outil peut comporter des risques Pour une liste compl te des accessoires pri re de se reporter au catalogue MILWAUKEE Electric Tool ou visiter le site internet www milwaukeetool com Pour obtenir un catalogue il
32. p liza de garant a sellada por el establecimiento donde realiz la compra Ah se reemplazar cualquier pieza o componente defectuoso sin cargo alguno para el usuario final La empresa se hace responsable de los gastos de transportaci n razonablemente erogados que se deriven del cumplimiento de la presente garant a Excepciones La garant a perder validez en los siguientes casos a Cuando el producto se hubiese utilizado en condiciones distintas a las normales b Cuando el producto no hubiese sido operado de acuerdo con el instructivo de uso que le acompa a c Cuando el producto hubiese sido alterado o reparado por personas no autorizadas por TECHTRONIC INDUSTRIES Nota Si el cord n de alimentaci n es da ado este debe ser remplazado por el fabricante o por un Centro de Servicio Autorizado para evitar riesgo Modelo CENTRO DE SERVICIO Y ATENCI N A CLIENTES Rafael Buelna No 1 Col Tezozomoc Mexico D F Fecha de Compra Tel 01 800 832 1949 Sello del Distribuidor IMPORTADO Y COMERCIALIZADO POR TECHTRONIC INDUSTRIES MEXICO S A DE C V Av Santa Fe 481 piso 6 Col Curz Manca CP 05349 Cuajimalpa D F 18 19 UNITED STATES MILWAUKEE Service MILWAUKEE prides itself in producing a premium quality product that is NoTHING BUT Heavy Duty Your satisfaction with our products is very important to us If you encounter any problems with the operation of this tool or you would like to locate the factory
33. peraci n para el term metro infrarrojo Temp Gun de MILWAUKEE Antes de utilizar el term metro Temp Gun lea este manual del operador y todas las etiquetas del term metro SEGURIDAD L SER Luz l ser No mire fijamente el haz de rayos l ser ni lo mire directamente con instrumentos pticos No apunte la luz l ser en direcci n a otras personas La luz l ser puede provocar dafios a los ojos Evite la exposici n a la radiaci n l ser El l ser puede emitir radiaci n peligrosa No apunte el l ser a superficies reflactantes Pueden producirse resultados impredecibles SEGURIDAD EN EL AREA DE TRABAJO Mantenga alejados a ni os y personas pre sentes mientras utiliza el Temp Gun Cuando no est en uso guarde el Temp Gun fuera del alcance de los nifios y no permita que las personas que no est n familiarizadas con la herramienta o con estas instrucciones la operen Evite los entornos peligrosos No use este pro ducto bajo la lluvia la nieve ni en lugares h medos o mojados No lo use en atm sferas explosivas emanaciones de gas polvo o materiales inflam ables ya que al introducir o quitar la bater a se pueden generar chispas lo que posiblemente producir un incendio SEGURIDAD PERSONAL Permanezca alerta preste atenci n a lo que est haciendo y use el sentido com n al utilizar el Temp Gun No use este producto si est cansado o se encuentra bajo los efectos de las drogas el a
34. principale temp rature de surface et la lecture de la mesure secondaire temp rature maximale minimale moyenne ou diff rentielle 3 Rel cher ensuite la g chette L indication HOLD Retenue s affiche jusqu ce que l cran s teigne cela prend environ sept sec ondes NOTE Un changement brusque de la tem p rature gt 5 C affecte les lectures de l unit Permettre l unit d atteindre la temp rature ambiante avant de l utiliser 5 30 minutes selon le changement de temp rature R glage du verrou de la g chette Pour activer et d sactiver le verrou de la g chette tirer la g chette et appuyer sur le bouton REGLAGE SET cinq fois Appuyer sur les boutons au dessus des fl ches Haut et Bas pour basculer entre Marche et Arr t Attendre 5 secondes pour enregistrer le r glage et quitter A F Len CL u e 183 e 69 H Je LO Alarme de la temp rature Appuyer sur le bouton Alarm Alarme pour activer la fonction d alarme L ic ne de cloche ap parait Si la temp rature mesur e se situe l ext rieur de la plage pr tablie la lecture de temp ra ture clignote Choix de la plage de pr r glage pour l alarme 1 Pour r gler la plage de l alarme tirer la g chette et appuyer sur le bouton REGLAGE SET R p ter l op ration afin de basculer entre les r glages HI Elev et LO Faible 2 Appuyer sur les fleches Haut ou Bas des touches
35. r de la date d achat L enregistrement de la garantie n est pas n cessaire pour b n ficier de la garantie en vigueur sur un produit MILWAUKEE La date de fabrication du produit servira tablir la p riode de garantie si aucune preuve d achat n est fournie lorsqu une demande de service sous garantie est faite L ACCEPTATION DES RECOURS EXCLUSIFS DE R PARATION ET DE REMPLACEMENT D CRITS AUX PR SENTES EST UNE CONDITION DU CONTRAT D ACHAT DE TOUT PRODUIT MILWAUKEE SI VOUS N ACCEPTEZ PAS CETTE CONDITION VOUS NE DEVEZ PAS ACHETER LE PRODUIT EN AUCUN CAS MILWAUKEE NE SAURAIT TRE RESPONSABLE DE TOUT DOMMAGE ACCESSOIRE SP CIAL OU INDIRECT DE DOMMAGES INT R TS PUNITIFS OU DE TOUTE D PENSE D HONORAIRES D AVOCATS DE FRAIS DE PERTE OU DE D LAIS ACCESSOIRES TOUT DOMMAGE D FAILLANCE OU D FAUT DE TOUT PRODUIT Y COMPRIS NOTAMMENT LES PERTES DE PROFIT CERTAINS TATS ET PROVINCES NE PERMETTANT PAS L EXCLUSION OU LALIMITATION DES DOMMAGES DIRECTS OU INDIRECTS LES RESTRICTIONS CI DESSUS PEUVENT NE PAS TRE APPLICABLES CETTE GARANTIE EST EXCLUSIVE ET REMPLACE TOUTE AUTRE GARANTIE EXPRESSE QU ELLE SOIT VERBALE OU CRITE DANS LA MESURE PERMISE PAR LA LOI MILWAUKEE RENONCE A TOUTE GARANTIE IMPLICITE Y COMPRIS SANS S Y LIMITER TOUTE GARANTIE IMPLICITE DE QUALIT MARCHANDE OU D ADAPTATION UNE UTILISATION OU UNE FIN PARTICULI RE DANS LA MESURE OU UNE TELLE STIPULATION D EXON RATION N EST PAS PERMISE PAR LA LOI LA DUR E DE CES GA
36. r de modo ENSAMBLAJE A ADVERTENCIA Recargue la bater a s lo con el cargador especificado para ella Para instrucciones espec ficas sobre c mo cargar lea el manual del operador suministrado con su cargador y la bater a 15 Instalaci n Cambio de las bater as 1 Con un destornillador plano gire el seguro de la puerta de la bater a a la posici n desblo queada y abra la puerta de la bater a 2 Conecte una 1 bater a de 9V al bloque conec tor Inserte la bater a en el compartimiento 3 Cierre la puerta de la bater a Gire el seguro de la puerta de la bater a a la posici n de bloqueo Selecci n de Celsius o Fahrenheit Para configurar la escala de temperatura jale el gatillo y luego oprima el bot n SET configurar tres veces Presione los botones que se encuentran sobre las flechas ascendente y descendente para cambiar entre C y F Espere 5 segundos para guardar la configuraci n y salga Distancia al objetivo 10 1 2267 20 12 1 2268 20 NOTA Un cambio r pido en la temperatura gt 5 C afecta las lecturas de la unidad Deje que la uni dad alcance la tempera tura ambiente antes de usarla 5 a 30 minutos dependiendo del cambio de temperatura Configuraci n del seguro l ser Para encender y apagar el seguro l ser jale el ga tillo y luego oprima el bot n SET configurar cuatro veces Presione los botones que se encuentran sobre las flechas asc
37. reducir el riesgo de una explosi n no queme nunca una bater a aun si est da ada muerta o completamente descargada Limpieza Limpie el polvo y los desechos de la herramienta Mantenga los mangos de la herramienta limpios secos y sin aceite ni grasa Use solamente jab n suave y un pa o h medo para limpiar la herra mienta ya que algunos agentes de limpieza y sol ventes son da inos para los pl sticos y otras partes aisladas Algunos de estos son gasolina aguarr s decapante para laca decapante para pintura solventes para limpieza con cloro amon aco y detergentes dom sticos que contienen amon aco Nunca use solventes inflamables ni combustibles cerca de las herramientas Reparaciones Para realizar reparaciones env e la herramienta al centro de servicio m s cercano que figure en la contraportada de este manual del operador ACCESORIOS ADVERTENCIA Para reducir el riesgo de lesiones siempre extraiga la bater a antes de cambiar o retirar accesorios Utilice nicamente accesorios especificamente recomendados para esta herramienta El uso de accesorios no recomendados podr a resultar peligroso Para una lista completa de accessorios refi rase a su cat logo MILWAUKEE Electric Tool o visite nuestro sitio en Internet www milwaukeetool com Para obtener un cat logo contacte su distribuidor local o uno de los centros de servicio GARANT A LIMITADA E U A Y CAN
38. stablecido la lectura de la temperatura titilar Ajuste del rango preconfigurado de la alarma 1 Para configurar el rango de la alarma jale el gatillo y luego oprima el bot n SET configu rar Repita para cambiar en tre las configuraciones ALTA y BAJA 2 Presione las teclas blandas de la flecha ascendente o de scendente para cambiar entre las temperaturas Espere 5 segundos para que se guarden los rangos y salga ADVERTENCIA Para reducir el riesgo de lesiones siempre retire las bater as de la herramienta antes de realizar man tenimiento Nunca desarme la herramienta Comun quese con una instalaci n de servicio MILWAUKEE para que se realicen TODAS las reparaciones Mantenimiento de la herramienta Mantenga su herramienta en buenas condiciones adoptando un programa de mantenimiento regular Despu s de un per odo de entre seis meses y un a o seg n el uso env e la herramienta a una instalaci n de servicio MILWAUKEE para Si la herramienta no enciende o no funciona al m ximo de potencia con bater as completamente cargadas limpie los contactos de la puerta de las bater as Si la herramienta a n no funciona cor rectamente env ela a una instalaci n de servicio MILWAUKEE para que la reparen Limpieza de la lente Elimine todas las part culas sueltas con aire com primido limpio Limpie cuidadosamente la superfi cie con un hisopo humedecido con agua 17 ADVERTENCIA Para
39. suffit de contacter votre distributeur local ou l un des centres service Les produits d essai et de mesure MILWAUKEE y compris l outil les blocs piles au lithium ion et le chargeur mais non les piles alcalines sont garantis l acheteur d origine tre exempt de vice du mat riau et de fabrication Sous r serve de certaines exceptions MILWAUKEE r parera ou remplacera toute pi ce de ce produit qui apr s examen par MILWAUKEE s av re tre affect d un vice du mat riau ou de fabrication pendant une p riode de cinq 5 ans apr s la date d achat Retourner l outil d essai et de mesure accompagn d une copie de la preuve d achat au centre de r parations en usine MILWAUKEE soci t d outils lectriques le plus pr s Cette garantie ne couvre pas les dommages que MILWAUKEE d termine tre caus s par des r parations ou des tentatives de r paration par quiconque autre que le personnel agr par MILWAUKEE des utilisations incorrectes des alt rations des utilisations abusives une usure normale une carence d entretien ou les accidents La p riode de la garantie du bloc piles au lithium ion qui est fourni avec l outil d essai et de mesure est de deux 2 ans compter de la date d achat La pile alcaline qui est fournie avec l outil d essai et de mesure b n ficie d une garantie distincte accord e par le fabricant de la pile La p riode de la garantie d un DETECTEUR DE TENSION SANS CONTACT 2201 20 est d un 1 an parti
40. t a para obtener la garant a correspondiente de los productos MILWAUKEE Se usar la fecha de fabricaci n del producto para determinar el per odo de garant a en caso de no presentarse el comprobante de la compra en el momento de solicitar el servicio de garant a LAACEPTACI N DE LOS DERECHOS A REPARACI N Y REEMPLAZO EXCLUSIVAMENTE DESCRITOS EN EL PRESENTE DOCUMENTO CONSTITUYE UNA CONDICI N DEL CONTRATO POR LA COMPRA DE CADA PRODUCTO MILWAUKEE SI NOACEPTAESTA CONDICI N NO DEBE COMPRAR EL PRODUCTO MILWAUKEE NO SER EN NING N CASO RESPON SABLE DE DANOS INCIDENTALES ESPECIALES CONSECUENTES O PUNITIVOS NI DE COSTOS HONORARIOS DE ABOGADOS GASTOS P RDIDAS O DEMORAS SUPUESTAMENTE CAUSADOS COMO CONSECUENCIADE CUALQUIER DA O FALLA O DEFECTO EN CUALQUIER PRODUCTO INCLUIDOS AMODO DE EJEMPLO RECLAMOS POR P RDIDA DE GANANCIAS ALGUNOS ESTADOS NO PERMITEN LA EXCLUSI N O LA LIMITACI N DE DA OS INCIDENTALES O CONSECUENTES POR LO TANTO LAS LIMITACIONES Y EXCLUSIONES ANTERIORES PUEDEN NO APLICARSE PARA USTED ESTA GARANT A ES EXCLUSIVA Y SUSTITUYE A TODAS LAS OTRAS GARANT AS EXPRESAS ESCRITAS U ORALES SEG N LO PERMITA LA LEY MILWAUKEE SE EXIME DE TODA GARANT A IMPL CITA INCLUIDOS AMODO DE EJEMPLO TODA GARANT A IMPL CITA DE COMERCIABILIDAD O IDONEIDAD PARA UN USO O PROP SITO EN PAR TICULAR ENLAMEDIDAEN QUE DICHA RENUNCIA NO EST PERMITIDA POR LA LEY DICHAS GARANT AS IMPL CITAS EST N LIMITADAS A LA DURACI N DE LA GARANTIA EX
41. tery door lock to the locked position Selecting Celsius or Fahrenheit To set the temperature scale pull the trigger and then press the SET button three times Press the buttons above the up and down arrows to toggle between C and F Wait 5 seconds for the setting to save and exit Setting the Laser Lock To turn the laser on and off pull the trigger and then press the SET button four times Press the buttons above the up and down arrows to toggle between ON and OFF Wait 5 seconds for the set ting to save and exit Distance to Spot 10 1 2267 20 12 1 2268 20 NOTE A quick change in temperature gt 10 F affects the meter s read ings Allow the meter to reach ambient tempera ture before use 5 to 30 minutes depending on temperature change Center of Spot Laser pointer approx 3 4 above center of spot C Spot size at distance indicated 2267 20 amp 2268 20 At 1 away spot is 1 5 in diameter 2267 20 At 3 away spot is 3 6 in diameter 2268 20 At 3 away spot is 3 in diameter 2267 20 At 5 away spot is 6 in diameter 2268 20 At 5 away spot is 5 in diameter OPERATION Scanning Object Temperature 1 Pull and hold the trigger for at least 2 seconds and scan the surface temperature of an object A laser pointer is used for aiming on the area being scanned A A NOTE The object should be larger than the spot being q ba scanned If not readings wil
42. tive surfaces Un predictable results may occur WORK AREA SAFETY Keep children and bystanders away while op erating Temp Gun Store idle Temp Guns out of the reach of children and do not allow persons unfamiliar with the tool or these in structions to operate them eAvoid dangerous environments Do not use in rain snow damp or wet locations Do not use in the presence of explosive atmospheres gaseous fumes dust or flammable materials because sparks may be generated when inserting or remov ing batteries possibly causing fire PERSONAL SAFETY Stay alert watch what you are doing and use common sense when operating Temp Gun Do not use while you are tired or under the influence of drugs alcohol or medication A moment of inattention may result in serious per sonal injury Do not overreach Keep proper footing and balance at all times This enables better control in unexpected situations BATTERY USE AND CARE This tool is designed to be powered by one 1 9V battery properly inserted into the MILWAUKEE Temp Gun Do not attempt to use with any other voltage or power supply Do not leave battery within the reach of chil dren Install battery according to polarity diagrams eProperly dispose of used batteries immedi ately Do not incinerate or dismantle batteries Under abusive conditions liquid may be eject ed from the battery avoid contact If contact accidentally occurs
43. ttempted by anyone other than MILWAUKEE autho rized personnel misuse alterations abuse normal wear and tear lack of maintenance or accidents The warranty period for the LITHIUM ION battery pack that ships with the Test amp Measurement tool is two 2 years from the date of purchase Alkaline battery that ships with Test amp Measurement tool is separately warranted by the battery manufacturer The warranty period for a NON CONTACT VOLT AGE DETECTOR 2201 20 is one 1 year from the date of purchase Warranty Registration is not necessary to obtain the applicable warranty on MILWAUKEE product The manufacturing date of the product will be used to de termine the warranty period if no proof of purchase is provided at the time warranty service is requested ACCEPTANCE OF THE EXCLUSIVE REPAIRAND REPLACE MENT REMEDIES DESCRIBED HEREIN IS A CONDITION OF THE CONTRACT FOR THE PURCHASE OF EVERY MILWAUKEE PRODUCT IF YOU DO NOT AGREE TO THIS CONDITION YOU SHOULD NOT PURCHASE THE PROD UCT IN NO EVENT SHALL MILWAUKEE BE LIABLE FOR ANY INCIDENTAL SPECIAL CONSEQUENTIAL OR PUNI TIVE DAMAGES OR FOR ANY COSTS ATTORNEY FEES EXPENSES LOSSES OR DELAYS ALLEGED TO BE AS A CONSEQUENCE OF ANY DAMAGE TO FAILURE OF OR DEFECT IN ANY PRODUCT INCLUDING BUT NOT LIMITED TO ANY CLAIMS FOR LOSS OF PROFITS SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APP