Home

dyna-wave centrifugal pump with integral trap

image

Contents

1. Pump Valves OK between X ee pump and Tee Figure 2 Recommended pump suction layout 2762 0197 Testing and Certification Suction outlet covers must have been tested by a nation ally recognized testing laboratory and found to comply with the latest ASME ANSI Specifications for Suction Fittings For Use in Swimming Pools Spas Hot Tubs and Whirlpool Bathtub Applications Fittings Fittings restrict flow for best efficiency use fewest possi ble fittings but at least two suction outlets Avoid fittings which could cause an air trap Pool fittings must conform to International Association of Plumbing and Mechanical Officials I APMO standards Use only non entrapping suction fitting or double suction ELECTRICAL Ground motor before connecting to electrical power supply Failure to ground motor can cause severe or fatal electrical shock hazard A Do not ground to a gas supply line A To avoid dangerous or fatal electrical shock turn OFF power to motor before working on electrical connections A Ground Fault Circuit Interrupter GFCI tripping indicates an electrical problem If GFCI trips and will not reset have a qualified electrician inspect and repair electrical system A Exactly match supply voltage to nameplate voltage Incorrect voltage can cause fire or seriously dam age motor and voids warranty If in doubt consult a li censed electrician Voltage Voltage at motor mu
2. Voltage Sticker 1 U27 153 e Decal Overtight trap lid 1 U27 644 Tag WARNING CAUTION Instructions 1 C63 12 e Not illustrated 10 TROUBLESHOOTING GUIDE Read and understand safety and operating instruc tions in this manual before doing any work on pump Only qualified personnel should electrically test pump motor FAILURE TO PUMP REDUCED CAPACITY OR DISCHARGE PRESSURE Suction leaks lost prime 1 Pump must be primed make sure that pump volute and trap are full of water See priming instructions Page 7 2 Make sure there are no leaks in suction piping 3 Make sure suction pipe inlet is well below the water level to prevent pump from sucking air 4 If suction trap gasket is defective replace it 5 Make sure pump is not trying to lift water more than 10 3m 6 Make sure suction pipe is at least 2 51mm in diameter Clogged pipe trap impeller worn impeller 7 Make sure suction trap is not clogged if it is clean trap and strainer 8 Make sure impeller is not clogged follow steps 1 through 7 under Removing Old Seal Page 9 check impeller for clogging follow steps 7 through 11 under Installing New Seal Page 9 for reassembly 9 Impeller and diffuser may be worn If so order replace ment parts from Repair Parts List Page 10 A WARNING Hazardous voltage Can shock burn or cause death Disconnect power before working on pump or
3. V lvulas OK entre la XH bomba y el Te Pea Bomba 2162 0197 Figura 2 Configuraci n recomendada de la aspiraci n de la bomba Pruebas y certificaci n Las cubiertas de la salida de aspiraci n deben haber sido verifi cadas por un laboratorio de pruebas reconocido a nivel nacional conforme a la versi n m s reciente de las Especificaciones de ASME ANSI para Accesorios de Aspiraci n que se usen en Albercas Jacuzzis Ba os termales y Piscinas de Hidromasaje Accesorios Los accesorios limitan el flujo para mayor eficacia use la m n ima cantidad posible de accesorios pero al menos dos salidas de aspiraci n Evite accesorios que puedan provocar una trampa de aire Los accesorios para albercas deben cumplir con las normas de la International Association of Plumbing and Mechanical Officials IAPMO Use solamente accesorios de aspiraci n que no provoquen enre dos o de doble aspiraci n INFORMACION ELECTRICA Conecte el motor a tierra antes de conectarlo a la fuente de corriente el ctrica de lo contrario existe el peligro de choque el ctrico grave o fatal A No haga la conexi n a tierra mediante una l nea de sum inistro de gas A Para evitar choques el ctricos peligrosos o fatales de sconecte la alimentaci n el ctrica al motor antes de tra bajar en las conexiones el ctricas A El disparo del disyuntor de escape a tierra GFCI seg n sus siglas en ingl s indica un pro
4. debajo de 5 PSI cuando purgue el aire de la bomba del filtro o de la tuber a A ADVERTENCIA Tensi n peligrosa Puede provocar choques el ctricos quemaduras o muerte Desconecte la alimentaci n el ctrica antes de trabajar con la bomba o con el motor PARA SACAR UNA TAPA DEMASIADO APRETADA Figura 6 Use una barra o una tabla de apalancar seg n se ilustra para sacar una tapa apretada No use una barra de apalancar para apretar la tapa 1 Baje el nivel del agua por debajo de todos los orificios de ad misi n a la alberca A Para evitar el riesgo de choques el ctricos peligrosos o fa tales desconecte la alimentaci n el ctrica al motor antes de drenar la bomba 2 Saque la cubierta del sif n y use aire a baja presi n para so plar el agua acumulada del sistema de tuber a Use una barra o una tabla de apalancar para sacar las cubiertas del colec torque est n demasiado apretadas o se hayan atascado y no se puedan sacar con la mano La tapa del colector tiene salientes para poder usar una palanca o una barra de apalan car consulte la Figura 6 3 Tape la tuber a de admisi n despu s de drenar para man tener el agua fuera de los ca os 4 Para impedir que la bomba se congele saque la cubierta del colector y drene la unidad del tanque a trav s de los dos tapones de drenaje provistos A Drene el sistema lo m s posible por gravedad B Proteja las reas que retienen agua con un
5. 8 AWG 8 4 mm o mayor Haga correr el cable desde la saliente externa de empalme consulte la Figura 3 a la vara o malla de refuerzo Conecte un cable de empalme de cobre macizo No 8 AWG 8 4 mm al conector del cable de presi n suministrado en la caja del motor y a todas las partes met licas de la alberca el jacuzzi o el ba o termal y a todo equipo el ctrico tuber a met lica o conducto dentro de una distancia de 5 pies 1 5 m de los muros interiores de la alberca el jacuzzi o el ba o termal Saliente de empalme Tornillo verde de is puesta a S tierra Figura 3 Ubicaciones t picas del tornillo de puesta a tierra y de la saliente de empalme Cableado AVISO Los modelos trif sicos requieren arranques de motor magn ticos y protecci n externa contra sobrecarga En caso de duda sobre el procedimiento consulte a un electricista certificado La bomba debe estar permanentemente conectada al circuito La Tabla 1 p gina 6 indica los tama os correctos de los cables y disyuntores para la bomba sola Si se conectan otras luces o aparatos electrodom sticos al mismo circuito aseg rese de agre gar las cargas de amperaje a la carga de amperaje de la bomba antes de determinar los tama os correctos para los cables y disyuntores Si no est seguro o est confundido consulte a un electricista certificado Use el disyuntor de carga como interruptor maestro de encendido y apagado Instale un disyuntor de esc
6. A PRECAUCI N Esta bomba se debe usar en albercas de instalaci n permanente y se puede usar con ba os termales y jacuzzis si as se indica No la use con albercas desmonta bles Una alberca de instalaci n permanente est construida dentro o sobre el suelo o en un edificio y no se puede de sarmar f cilmente para guardarla Una alberca desmontable se ha construido de manera que se pueda desarmar f cil mente para guardarle y se pueda volver a armar para obtener su integridad inicial CONSERVE ESTAS INSTRUCCIONES INSTALACI N La bomba y los cables deben ser instalados s lo por personas competentes y autorizadas Cubierta de la cesta colectora Orificio de descarga Orificio de aspiraci n lt La bomba se puede empernar a una base nivelada o a un soporte de montaje Figura 1 AVISO Las roscas de los orificios son Internos 2 NPT para conexi n directa a la tuber a Externas 3 1 4 Trapezoidal Se adapta al collar n de uni n Sta Rite U11 200P para una conexi n a tubos de desconexi n r pida Consulte la p gina 10 para los juegos de uniones La instalaci n de la bomba debe Estar ubicada lejos de l quidos corrosivos o inflamables Tener suficiente ventilaci n para mantener la temperatura del aire por debajo de la clasificaci n m xima de temperatura ambi ente M x Amb indicada en la placa del modelo del motor Si esta bomba est instalada en un r
7. PROPIETARIO uniones opcionales INSTALACI N OPERACI N Y PIEZAS Modelo MPRA6B 143L Este manual se debe entregar al usuario final de esta bomba su uso reducir las llamadas de servicio y las posibilidades de lesiones y alargar la vida til de la bomba Sta Rite Pool Spa Group 293 Wright Street Delavan WI 53115 Internacional 262 728 5551 FAX 262 728 7550 www starite com Union City TN Delavan WI Mississauga Ont Murrieta CA 2006 Sta Rite Industries 752 9 8 06 BOMBA DE LA SERIE MPRA CON COLECTOR Para evitar llamadas innecesarias de servicio evitar posibles lesiones y obtener el m ximo de su bomba LEA ESTE MANUAL CON ATENCION La bomba centr fuga autocebadora de la Serie MPRA de Sta Rite e Ha sido dise ada para usar con agua o como bomba centr fuga e Tiene un desempe o excelente es duradera y fiable ndice Instrucciones de seguridad oooocococccconcccnoncccnnncncnonnccnnnnno 2 Instalacion dia dica 3 Requerimientos de aspiraci n para bombas de albercaS cocooooccccnnonocnncconoonnnnccnnnnnss 4 5 Informaci n el ctriCa seients innii 5 6 A AO 7 Almacenamiento Preparaci n para el invierno 7 8 Servicio de la boMba coooooccnnocccnoccccnconcnnnncconnnnccnnnnos 8 10 Lista de piezas para reparaciones coooccccccoooncnocoonnninonnns 10 Gu a para la localizaci n de fallaS oooonninnnnncnnnnccnnn 11 Garantia sesura tac 12 LEA Y SI
8. Qty 2 Ver Cuadro A Clave Descripci n MPRA6B 143L No de la pieza Cantidad 1 3 HP 1 Motor 115 230V 1750 RPM 1 62003 2088 2 Tornillo 10 32 x 1 2 1 U30 692SS 3 Saliente de empalme 1 U17 568 4 Deflector 1 17351 0009 5 Plancha de estanqueidad 1 C3 184P 6 Cord n anular de la plancha de estanqueidad 1 U9 373 7 Sello del eje 1 37400 0027S 8 Impulsor 1 C105 236PDA 8A O Ring Gasket 1 33455 1047 8B Impeller Screw 1 37337 6080 9 Difusor 1 C1 270P 10 Aro t rico del difusor 1 U9 374 11 Unidad de tanque y colector solamente 1 C76 58P 12 Cubierta del colector 1 C3 185P 13 Aro t rico de la cubierta del colector 1 U9 375 14 Cesta del colector 1 C8 58P 15A Tap n de drenaje 2 U178 920P 15B Tornillo de montaje de 5 16 14 x 5 8 2 U30 919SS 16 Base 1 C4 77P 17 Cojinete del motor 1 35 45 18 Tornillo 8 32 x 7 8 cabeza redonda 7 U30 542SS 19 Arandela de fijaci n 8 diente alargado 7 U43 21SS 20 Arandela plana de 3 8 6 U43 62SS 21 Arandela de fijaci n 3 8 6 U43 12SS 22 Tuerca de 3 8 16 Hexagonal Lat n chapado en n quel 6 71403 23 Tornillos prisioneros de 3 8 16 x 1 Hexagonales 4 U30 74SS Placa de f brica 1 32155 4071 Etiqueta PRECAUCI N Esta bomba viene 1 U63 13 equipada con un sello de eje mec nico Etiqueta de tensi n voltaje 1 U27 153 Calcoman a tapa de sif n demasiado apretada 1 U27 644 Etiqueta ADVERTENCIA PRECAUCI N Instrucciones 1 C63 12 e No s
9. Year Lamps and Bulbs 90 Days White Goods 1 Year Maintenance Equipment 90 Days Drainer Utility Pumps 90 Days Replacement Parts 90 Days Cleaners Lil Shark 1 Year Cleaners Calypso 1 Year Cleaners Pool Shark 2 Years Footpad and Seal Flaps 1 Yr Cleaners Great White 2 Years Retain this warranty certificate in a safe and convenient location for your records For technical information about this product contact the installer or call Sta Rite at 262 728 9181 Visit www staritepool com for more information about Sta Rite products listed above to locate a Sta Rite dealer near you CREATE A RECORD OF YOUR WARRANTY AT STA RITE e Complete a warranty registration at www staritepool com by clicking on Register Products and selecting Sta Rite Pool OR e Complete bottom portion completely and mail within 10 days of installation to Sta Rite Attn Warranty Dept 293 Wright St Delavan WI 53115 STA RITE y Warranty Registration Card Name New installation Replacement Address Years pool has been in service less than 1 1 3 3 5 5 10 City State Zip This product was purchased from Installation or Purchase Date Company name Product Purchased Address Model Number City State Zip S4877PS Rev 5 28 04 STA RITE DYNA WAVE BOMBA CENTR FUGA CON COLECTOR INTEGRAL MANUAL DEL
10. and may also be used with hot tubs and spas if so marked Do not use with storable pools A permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage A storable pool is con structed so that it may be readily disassembled for stor age and reassembled to its original integrity SAVE THESE INSTRUCTIONS
11. interior de la mitad giratoria del sello 7 Deslice la unidad giratoria del sello con la superficie de carb n hacia afuera sobre el manguito del impulsor hasta que el aro accionador de caucho toque la parte posterior del impulsor AVISO Aseg rese de no cortar ni rayar la superficie pulida del sello ya que el sello gotear con una superficie da ada 8 Atornille el impulsor en el eje hacia la derecha esto colocar el sello autom ticamente en la plancha de estanqueidad AVISO En los modelos de 2 y 2 1 2 HP instale la empaque tadura del impulsor y el tornillo de sujeci n rosca izquierda gire hacia la izquierda La torsi n del tornillo de sujeci n debe ser de 50 55 pulgada libra 57 6 63 kg cm 9 Monte el difusor sobre la plancha de estanqueidad apriete los tornillos a una torsi n de 10 14 pulgada libra 11 2 16 1 kg cm 10 Ensamble el motor y la plancha de estanqueidad a la unidad de la bomba con tuercas arandelas planas y arandelas de fijaci n La torsi n de las tuercas debe ser de 120 130 pulgada libra 138 150 kg cm 11 Cebe la bomba seg n las instrucciones que aparecen en la p gina 7 Cuadro A Paquete 188 con juego de uni n de 1 2 corredizo de 2 Note that this kit includes both inlet and outlet connections LISTA DE PIEZAS PARA REPARACIONES Incluye Collar n de uni n U11 200PS Qty 2 Aro t rico U9 362 Qty 2 Adaptador U11 196PS corredizo de 2
12. negligence misapplication improper installation or maintenance or other circumstances which are not in Sta Rite s direct control Failure to have product installed by a professional in compliance with local codes will void any and all manufacturers warranty This warranty sets forth Sta Rite s obligation and Purchaser s ex clusive remedy for defective products STA RITE SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL INCIDENTAL OR CONTINGENT DAMAGES WHATSOEVER THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES IMPLIED WAR RANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SHALL NOT EXTEND BEYOND THE DURATION OF THE APPLICABLE EXPRESS WARRANTIES PROVIDED HEREIN Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied war ranty lasts so the above limitations or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Supersedes all previous publications Product Specific Warranties from date of installation Product Limited Family Warranty Exceptions Filters 1 Year System 3 Tank Bodies 10 Yrs Filter Valves 1 Year Pumps 1 Year Heaters 2 Years Commercial Application 1 Yr Controls 1 Year Above Ground Systems 1 Year Lights and Niches 1
13. que no est averiado ni tenga abrasi n 11 Limpie la cavidad del sello en la plancha de estanqueidad y limpie el eje del motor Sello mec nico asiento de cer mica Figura 7 Re ensamblaje de la bomba Instalaci n de un sello nuevo 1 El asiento de cer mica debe estar limpio y sin suciedad grasa polvo etc Humedezca el borde exterior con una pe que a cantidad de detergente l quido oprima el asiento de cer mica en la cavidad de la plancha de estanqueidad firme mente haciendo presi n con el dedo Figura 8 Superficie pulida Superficie de caucho Figura 8 2 Si el asiento de cer mica no encaja debidamente s quelo col quelo boca arriba sobre un banco y vuelva a limpiar la cavi dad El asiento de cer mica ahora deber encajar debidamente 3 Si el asiento a n no encaja debidamente coloque una aran dela de cart n sobre la superficie pulida y use un trozo de ca o est ndar de 3 4 19 mm para hacer presi n AVISO Aseg rese de no rayar ni estropear la superficie o el sello gotear 4 Reemplace el deflector en el extremo del eje del motor de manera que el manguito del impulsor lo empuje en posi ci n Si se observan se ales de desgaste o aver a en el de flector c mbielo 5 Vuelva a instalar la plancha de estanqueidad en el motor Apriete los pernos a una torsi n de 60 80 pulgada libra 69 92 kg cm 6 Aplique una peque a cantidad de detergente l quido en el di metro
14. re ensamblar 9 Es posible que el Impulsor y el difusor est n gastados De ser as encargue piezas de repuesto de la Lista de Piezas para Reparaciones p gina 10 11 A ADVERTENCIA Problemas el ctricos 10 Es posible que la bomba est marchando demasiado lento verifique la tensi n en los bornes del motor y en el con tador mientras la bomba est funcionando Si el voltaje es bajo consulte las instruc ciones de cableado o consulte con la empresa de energ a Verifique que no haya conex iones flojas 11 Tensi n peligrosa Puede provocar choques el ctricos quemaduras o muerte Es posible que la bomba est demasiado caliente A Verifique la tensi n de l nea si es menor del 90 o mayor del 110 de la tensi n nominal consulte a un electricista certificado Desconecte la alimentaci n el ctrica antes de trabajar con la bomba o con el motor B Aumente la ventilaci n C Reduzca la temperatura ambiente D Ajuste toda conexi n floja PROBLEMAS MEC NICOS Y RUIDO 1 Si las tuber as de aspiraci n y de descarga no est n debida mente sujetas ejercer n tensi n sobre la unidad de la bomba Consulte la secci n de Instalaci n P gina 3 2 No instale la bomba sobre una plataforma de madera Col quela en forma segura sobre una plataforma de hormig n para obtener un funcionamiento m s silencioso GARANT A LIMITADA DE STA RITE Las bombas los filtros espumadores l
15. GA LAS INSTRUCCIONES DE SEGURIDAD 4h Este es el s mbolo de alerta de seguridad Cuando usted vea este s mbolo en su sistema o en este manual busque alguna de las siguientes palabras de advertencia y est alerta a la posibilidad de lesiones personales AAA advierte acerca de los peligros que provo car n muerte lesiones personales graves o da os materiales considerables si se ignoran A ADVERTENCIA advierte acerca de los peligros que pueden provocar muerte lesiones personales graves o da os materiales considerables si se ignoran A PRECAUCI N advierte acerca de los peligros que provo car o pueden provocar lesiones personales o da os materiales menores si se ignoran La etiqueta AVISO indica instrucciones especiales que no est n relacionadas con los peligros Lea y siga cuidadosamente todas las instrucciones de seguridad en este manual y en la m quina Mantenga las etiquetas de se guridad en buen estado reemplace las que falten o est n da adas 42 ADVERTENCIA Las m quinas que se instalan o se prueban en forma incorrecta pueden fallar provocando lesiones graves o da os materiales considerables Cuando instale y opere la m quina es importante que lea y siga las instrucciones del manual del propietario Haga que un profe sional capacitado en instalaciones en albercas realice todas las pruebas de presi n 1 No conecte el sistema a un sistema de alta presi n o de aguas p
16. L CITAS DE COMERCIABILIDAD E IDONEIDAD PARA UN FIN ESPEC FICO Y NO SE EXTENDER N M S ALL DE LA DURACI N DE LAS GARANT AS EXPL CITAS CORRESPONDI ENTES SUMINISTRADAS EN LA PRESENTE Algunos estados no permiten la exclusi n o limitaci n de da os inci dentales o consecuentes o de limitaciones de tiempo sobre garant as impl citas de modo que es posible que las limitaciones o exclusiones que preceden no correspondan en su caso Esta garant a le otorga derechos legales espec ficos y es posible que usted tambi n tenga otros derechos que pueden variar de un estado al otro Reemplaza toda publicaci n anterior Garant as Espec ficas de los Productos a partir de la fecha de su instalaci n Familia de productos Garant a Limitada Excepciones Filtros 1 A o Unidades de tanque del Sistema 3 10 a os V lvulas de filtro 1 A o Bombas 1 A o Calentadores 2 A os Uso comercial 1 a o Controles 1 A o Sistemas sobre el suelo 1 A o Luces y nichos 1 A o L mparas y focos 90 D as Productos blancos 1 A o Equipo de mantenimiento 90 D as Bombas de drenaje uso general 90 D as Refacciones 90 D as Limpiadores Lil Shark 1 A o Limpiadores Calypso 1 A o Limpiadores Pool Shark 2 A os Pedales y charnelas selladoras 1 a o Limpiadores Great White 2 A os Guarde este certificado de garant a en u
17. STA RITE DYNA WAVE CENTRIFUGAL PUMP WITH INTEGRAL TRAP O W N ER S MAN UAL Unions optional INSTALLATION OPERATION amp PARTS Model MPRA6B 143L This manual should be furnished to the end user of this pump its use will reduce service calls and chance of injury and will lengthen pump life Sta Rite Pool Spa Group 293 Wright Street Delavan WI 53115 International 262 728 5551 FAX 262 728 7550 www starite com Union City TN Delavan WI Mississauga Ont Murrieta CA 2006 Sta Rite Industries 752 9 8 06 MPRA SERIES PUMP WITH TRAP To avoid unneeded service calls prevent possible in juries and get the most out of your pump READ THIS MANUAL CAREFULLY The Sta Rite MPRA Series Self priming Centrifugal pump e Is designed for use with water features or as a centrifugal pump e Is an excellent performer durable reliable Table of Contents Safety INStrUCtIONS occccoooooooooccnononocononnnnnonnnnnnnncnonininnnns 2 sta hati OM iras id 3 Pool Pump Suction Requirements cceeeeereeeeees 4 5 A O 5 6 OPeratiON seorsan ticas cs 7 Storage Winterizing ocoooooonccnnnnnoocccnnonnancnnononnncncnnnnnos 7 8 PUM Pr SERVICE elirus lane 8 10 Repair Parts List s 2 s 2ssdeveseevsinaraeassavevertnaneanseanararestaneae 10 Troubleshooting Guide cccccceeeeeerececeeeeeeeeeeeeneees 11 WAITANLY sanos 12 READ AND FOLLOW SAFETY INSTRUCTIONS This is the
18. a tuber a en la bomba y haga correr los ca os alej ndose de la misma Para evitar la creaci n de bolsas de aire incline el tubo de as piraci n ligeramente hacia arriba y hacia la bomba AVISO Para impedir inundaciones cuando saque la bomba para realizar trabajos de mantenimiento o de reparaci n todos los sistemas de aspiraci n inundados deber n tener v lvulas de compuerta en las tuber as de aspiraci n y de descarga Lake Chemical Co Chicago Illinois REOUERIMIENTOS PARA LA ASPIRACI N DE LA BOMBA A La aspiraci n de la bomba es peligrosa y puede atra par ahogar o desentra ar a los ba istas No use ni opere alber cas jacuzzis ba os termales ni otros sistemas acu ticos si ob serva que las cubiertas de las sal idas de aspiraci n faltan est n y rotas o flojas Siga los lineamientos que apare cen a continuaci n para la insta laci n de una bomba para reducir los peligros a los usuarios de albercas jacuzzis ba os ter males y otros sistemas acu ticos A PELIGRO Aspiraci n peligrosa Puede atrapar el cabello o partes del cuerpo provocando lesiones graves o muerte Pabu Protecci n para no la aspiraci n quedar atrapado El sistema de aspiraci n de la bomba debe ofrecer protecci n contra el peligro de que una persona o su cabello queden atrapados o enredados debido a la aspiraci n Cubiertas para la salida de aspiraci n Es necesario mantener todas las cubiertas de las
19. air purging the pump filter or piping A WARNING Hazardous voltage Can shock burn or cause death Disconnect power before working on pump or motor TO REMOVE OVERTIGHT Figure 6 Use a pry bar or board as shown to remove tight lid Do notuse a pry bar to tighten lid 1 Pump down water level below all inlets to the pool A To avoid dangerous or fatal electrical shock haz ard turn OFF power to motor before draining pump 2 Remove trap cover and use low pressure air to blow ac cumulated water from the piping system Use a pry bar or board to remove trap covers that have been overtight ened or have taken a set and cannot be removed by hand Lugs have been provided on the trap lid to use a lever or pry bar for loosening see Figure 6 3 Cap inlet piping after draining to keep water out of the pipes 4 To prevent pump from freezing remove trap cover and drain the tank body through the two drain plugs provided A Gravity drain system as far as possible B Protect areas which retain water with non toxic propylene glycol antifreeze RV antifreeze 5 Clean pump thoroughly replace trap cover NOTICE Tighten trap cover by hand only no wrenches If pump is not anchored use caution to not break attached piping 6 Be sure motor is kept dry and covered Startup For Winterized Equipment 1 Remove any temporary weather protection placed around system for shutdown 2 Follow filte
20. anticonge lante de propilenglicol que no sea t xico anticonge lante RV 5 Limpie la bomba a fondo y vuelva a colocar la cubierta del colector AVISO Apriete la cubierta del colector a mano solamente sin llaves de tuerca Si la bomba no est anclada tenga cuidado de no romper los ca os sujetos a la misma 6 Aseg rese de que el motor se mantenga seco y cubierto Arranque para m quinas preparadas para el in vierno 1 Retire toda protecci n provisoria contra la intemperie que se haya colocado alrededor del sistema para el per odo de in actividad 2 Siga las instrucciones del fabricante del filtro para reactivar el filtro 3 Inspeccione todos los cables el ctricos y verifique que no se hayan da ado o deteriorado durante el per odo de inactivi dad Haga que un t cnico de servicio competente repare todos los cables que as lo requieran Inspeccione y ajuste todas las conexiones herm ticas 5 Abra todas las v lvulas en las tuber as de aspiraci n y de regreso 6 Saque todos los tapones de preparaci n para el invierno del sistema de tuber as 7 Drene todo el anticongelante del sistema 8 Cierre todas las v lvulas de drenaje y reemplace todos los tapones de drenaje en el sistema de tuber as 9 Cebe la bomba seg n las instrucciones que aparecen en la p gina 7 SERVICIO DE LA BOMBA El servicio de la bomba debe ser realizado solamente por personas competentes Para obten
21. ape a tierra GFCI en el circuito ste detectar un cortocircuito a tierra y desconectar la corri ente el ctrica antes de que resulte peligroso para los usuarios de la alberca Consulte las instrucciones del fabricante para deter minar el tama o del GFCI requerido y los procedimientos de verificaci n del GFCI En caso de un corte de corriente verifique que el GFCI no se haya disparado lo cual impedir a un funcionamiento normal de la bomba Reposicione de ser necesario AVISO Si no usa un conducto para cablear el motor verifique que la abertura del cable en el extremo del motor est cerrada herm ti camente para impedir la entrada de suciedad insectos etc A ADVERTENCIA Riesgo de choque el ctrico peligroso o fatal Verifique que la alimentaci n el ctrica al circuito del motor est desconectada antes de trabajar con los cables las conexiones de los cables o con el motor Vuelva a colocar la cubierta del motor y las cubiertas de los otros cables antes de activar la alimentaci n el ctrica 1 Desconecte la alimentaci n el ctrica 2 Saque la cubierta del motor C mo cablear un motor de una sola velocidad y un s lo voltaje Hay dos bornes marcados L1 y L2 Conecte los conductores de alimentaci n a estos bornes Cualquiera de los cables se puede conectar a cualquier de los bornes C mo cablear un motor de doble voltaje Los motores de doble voltaje tienen una ficha para cambiar de 230 v
22. as luces submarinas ex cluyendo los focos y los accesorios fabricados por Sta Rite est n cu biertos por una garant a contra defectos en material y o mano de obra por un 1 a o desde la fecha inicial de instalaci n Las garant as que anteceden s lo le corresponden al consumidor comprador inicial Comprador Sta Rite Industries tendr la opci n de reparar o de reemplazar el producto defectuoso a su solo juicio Los Compradores deber n pagar todos los gastos de mano de obra y de env o necesarios para reemplazar el producto cubierto por esta garant a Las solicitudes de servicio bajo garant a se deber n realizar a trav s del concesionario instalador Esta garant a no se aplicar a ning n producto que haya sido sometido a negligencia mal uso in stalaci n inadecuada o mal mantenimiento o a cualquier otra circun stancia que no se encuentre bajo el control directo de Sta Rite Si este producto no ha sido instalado por un profesional conforme a los c digos locales esta garant a y todas las garant as de los fabricantes quedar n invalidadas Esta garant a establece la obligaci n de Sta Rite y el recurso exclu sivo del Comprador con respecto a los productos defectuosos STA RITE NO SE HAR RESPONSABLE DE NING N DA O CON SECUENTE INCIDENTAL O CONTINGENTE LAS GARANT AS QUE ANTECEDEN SON EXCLUSIVAS Y EN LUGAR DE TODA OTRA GARANT A EXPL CITA O IMPL CITA IN CLUYENDO PERO SIN LIMITARSE A LAS GARANT AS IMP
23. blema el ctrico Si el GFCI se dispara y no se reposiciona haga que un electricista competente inspeccione y repare el sistema el ctrico La ten si n de suministro debe corresponder exactamente a la tensi n indicada en la placa de f brica A Una tensi n incorrecta puede provocar incendios o causar da os considerables al motor y anular la garant a En caso de duda consulte a un electricista certificado Tensi n voltaje La tensi n en el motor no debe ser m s del 10 superior o infe rior a la tensi n nominal indicada en la placa de f brica 6 el motor se recalentar provocando un disparo de la sobrecarga y reduciendo la vida til del componente Si la tensi n es menor del 90 o mayor del 110 de la tensi n nominal cuando el motor est marchando a toda carga consulte con la empresa de energ a Conexi n a tierra Metalizaci n el ctrica Instale conecte a tierra empalme y conecte los cables del motor conforme a los requerimientos locales o del National Electrical Code Motor con conexi n permanente a tierra Use el borne verde a tierra suministrado debajo de la cubierta del motor o de la plan cha de acceso Consulte la Figura 3 use los cables del tama o y del tipo requeridos por el c digo Conecte el borne de conexi n a tierra del motor a la tierra del servicio el ctrico La metalizaci n el ctrica del motor se debe hacer a la estructura de la alberca Use un conductor de cobre macizo tama o No
24. blicas 2 Use la m quina s lo en instalaciones de agua o en albercas El aire atrapado en el sistema puede provocar explosiones VERIFIQUE que todo el aire haya salido del sistema antes de operar la m quina o de hacer una prueba Antes de realizar la prueba de presi n verifique lo siguiente e Inspeccione todas las abrazaderas los pernos las tapas y los accesorios del sistema antes de realizar una prueba e Libere todo el aire en el sistema antes de realizar una prueba e Ajuste las tapas del colector Sta Rite a una torsi n de 30 ft lbs 4 1 kg m para hacer la prueba e La presi n del agua para la prueba debe ser inferior a 25 PSI 7 5 kg cm e La temperatura del agua para la prueba debe ser inferior a 100 F 38 e Limite la prueba a 24 horas Despu s de realizarla inspec cione el sistema visualmente para verificar que est listo para funcionar Saque la tapa del colector y vuelva a ajustarlo a mano solamente AVISO Estos par metros corresponden s lo a m quinas Sta Rite Para m quinas que no son de la marca Sta Rite consulte con el fabricante Presi n peligrosa Qo INSTRUCCIONES IMPORTANTES DE SEGURIDAD Siempre observe las precauciones b sicas de seguridad con esta m quina que incluyen lo siguiente A ADVERTENCIA Para reducir el peligro de lesiones no permita que los ni os usen este producto a menos que est n bajo supervisi n estricta en todo momento
25. ds are Internal 2 NPT for direct con nection to pipe External 3 1 4 Buttress Fits Sta Rite U11 200P Union Collar for quick disconnect pipe connection See Page 10 for Union Kits Pump mount must Be located away from corrosive or flammable liquids Have enough ventilation to maintain air temperature at less than the maximum ambient temperature rating Max Amb listed on the motor model plate If this pump is installed in an enclosure pump house the enclosure must have ade quate ventilation and air circulation to keep the tempera ture in the enclosure at or below the motor s rated ambient temperature whenever the pump is running Be solid Level Rigid Vibration free To reduce vibra tion and pipe stress bolt pump to mount Allow pump suction inlet height to be as close to water level as possible Pump will not lift water more than 10 3m Allow use of short direct suction pipe To reduce friction losses Allow for gate valves in suction and discharge piping Have adequate floor drainage to prevent flooding Be protected from excess moisture Allow adequate access for servicing pump and piping 44 WARNING Fire and burn hazard Modern motors run at high temperatures To reduce the risk of fire do not allow leaves debris or foreign matter to collect around the pump motor To avoid burns when handling the motor let it cool for 20 minutes before trying to work on it NOTICE When connecting threaded
26. e If other lights or appliances are also on the same circuit be sure to add their amp loads to pump amp load before figuring wire and circuit breaker sizes If unsure how to do this or if this is confusing consult a licensed electrician Use the load circuit breaker as the master on off switch Install a Ground Fault Circuit Interrupter GFCI in circuit it will sense a short circuit to ground and disconnect power before it becomes dangerous to pool users For size of GFCI required and test procedures for GFCI see manufacturer s instruction In case of power outage check GFCI for tripping which will prevent normal pump operation Reset if necessary NOTICE If you do not use conduit when wiring motor be sure to seal wire opening on end of motor to prevent dirt bugs etc from entering AWARNING Risk of dangerous or fatal electrical shock Be sure that power to the motor circuit is off before working on wiring wiring connections or motor Re in stall the motor end cover and all other wiring covers be fore turning on the power 1 Turn off power 2 Remove the motor end cover To Wire a Single Speed Single Voltage Motor There are two terminals labeled L1 and L2 Attach the power leads to these terminals Either wire may attach to either terminal To Wire a Dual Voltage Motor Dual voltage motors have a plug to change from 230 volts factory setting to 115 volts 1 If you have 230 volts motor supply voltag
27. e confirm that the plug is set for 230 volts The arrow on the plug will point to the 230 volt position Note that plug only connects with one prong in this position 2 If you have 115 volt supply pull the plug straight up and place it on the two brass prongs as shown NOTE Arrow is highlighted for clarity A Figure 4A Voltage Change Figure 4B Voltage Change Plug Set for 230 Volts Plug Set for 115 Volts TABLE RECOMMENDED FUSING AND WIRING DATA Serv to Motor Dist in Ft M AWG Wire Size mm Motor Branch Fuse Max Load Voltage 0 100 101 200 201 300 Model HP Rating Amps Amps Hz Phase 0 30 30 60 60 90 MPRAGB 143L 1 3 15 15 4 2 2 1 115 230 60 1 14 14 2 2 14 14 2 2 12 14 3 2 1750 RPM 230 60 14 2 2 14 2 2 14 3 2 Time delay fuses are recommended instead of standard fuses in any motor circuit OPERATION NOTICE NEVER run pump dry Running pump dry may damage seals causing leakage and flooding Fill pump with water before starting motor 44 WARNING Before removing trap cover 1 STOP PUMP before proceeding 2 CLOSE GATE VALVES in suction and discharge pipes 3 RELEASE ALL PRESSURE from pump and piping system A If pump is being pressure tested be sure pressure has been released before removing trap cover AWARNING Do not block pump suc tion To do so with body may cause severe or fatal injury Small children using pool must ALWAYS have close adult superv
28. e ilustra 10 GU A DE LOCALIZACI N DE FALLAS Es importante leer y comprender las instrucciones de se A guridad y de operaci n en este manual antes de realizar trabajos en la bomba Las pruebas el ctricas del motor de esta bomba deben ser realizadas solamente por personas competentes NO BOMBEA CAPACIDAD O PRESI N DE DESCARGA REDUCIDA Fugas en la aspiraci n p rdida de cebadura 1 Es necesario cebar la bomba verifique que la voluta y el colector de la bomba est n llenos de agua Consulte las in strucciones de cebadura P gina 7 Verifique que no haya fugas en la tuber a de aspiraci n Verifique que la admisi n de la tuber a de aspiraci n est bien por debajo del nivel del agua para impedir que la bomba aspire aire 4 Sila empaquetadura del colector de aspiraci n es defectu osa c mbiela 5 Verifique que la bomba no est tratando de levantar agua a una altura mayor de 10 3 m 6 Verifique que la tuber a de aspiraci n tenga un di metro m nimo de 2 51 mm Tuber a colector impulsor tapado impulsor gastado 7 Verifique que el colector de aspiraci n no est tapado de lo contrario limpie el colector y el colador 8 Verifique que impulsor no est tapado siga los pasos 1 al 7 en la secci n Remoci n del sello viejo P gina 9 verifique que el impulsor no est tapado siga los pasos 7 al 11 en la secci n de Instalaci n del nuevo sello P gina 9 para
29. ecinto estaci n de la bomba el recinto deber tener una ventilaci n y una circulaci n de aire adecuadas para mantener la temperatura dentro del mismo a la temperatura ambiente nominal del motor o por debajo de la misma siempre que la bomba est funcionando Ser firme nivelada r gida sin vibraciones Para reducir las vi braciones y la tensi n en las tuber as emperne la bomba al dis positivo de montaje Permitir que la altura de la admisi n de aspiraci n de la bomba est lo m s cerca posible del nivel del agua La bomba no lev antar agua a m s de 10 pies de altura 3 m Permitir el uso de tubos de aspiraci n cortos y directos Para re ducir las p rdidas por fricci n Permitir la instalaci n de v lvulas de compuerta en los tubos de aspiraci n y de descarga Tener un desag e adecuado en el suelo para evitar inundaciones Estar protegida contra una humedad excesiva Permitir el acceso adecuado para los trabajos de servicio de la bomba y de las tuber as A ADVERTENCIA Peligro de incendio y de quemaduras Los motores modernos funcionan a altas temperaturas Para reducir el peligro de incendio no permita que hojas escombros o part cu las extra as se acumulen alrededor del motor de la bomba Para evitar quemaduras cuando se trabaje con el motor deje que ste se enfr e durante unos 20 minutos antes de manipularlo AVISO Cuando conecte un tubo fileteado directamente a la bomba use cin
30. end on vertical length of suction lift and horizontal length of suc tion piping If pump does not prime make sure that all valves are open suction pipe end is under water pump is not trying to lift water more than 5 1 5m and that there are no leaks in suction pipe See Troubleshooting Guide Page 11 Storage Winterizing NOTICE Allowing pump to freeze will damage pump and void warranty NOTICE Do not use anti freeze solutions except propy lene glycol in your pool spa system Propylene glycol RV antifreeze is non toxic and will not damage plastic system components other anti freezes are highly toxic and may damage plastic components in the system Drain all water from pump and piping when expecting freezing temperatures or when storing pump for a long time see instructions below Keep motor dry and covered during storage To avoid condensation corrosion problems do not cover pump with plastic For outdoor unprotected installations 1 Enclose entire system in a weatherproof enclosure 2 To avoid condensation corrosion damage allow venti lation do not wrap system in plastic 3 Use a 40 propylene glycol 60 water solution to protect pump to 50 F 46 C Draining Pump A WARNING Explosion hazard Purging the system with compressed air can cause components to explode with risk of severe injury or death to anyone nearby Use only a low pressure below 5 PSI high volume blower when
31. er los mejores resulta dos use s lo repuestos genuinos de f brica de Sta Rite Aseg rese de cebar la bomba p gina 7 antes de encenderla A PRECAUCI N Antes de retirar la cubierta del sif n 1 DETENGA LA BOMBA antes de continuar 2 CIERRE LAS V LVULAS DE COMPUERTA en las tuber as de aspiraci n y de descarga 3 LIBERE TODA LA PRESI N de la bomba y del sistema de tu ber as Tensi n peligrosa Puede provocar choques el ctricos quemaduras o muerte Desconecte la alimentaci n el ctrica antes de trabajar con la bomba o con el motor A Para evitar el riesgo de choques el ctricos peligrosos o fa tales desconecte la alimentaci n el ctrica al motor antes de drenar la bomba Exceptuando la lubricaci n del aro t rico de la cubierta del colector no se necesita realizar ning n tipo de lubricaci n y mantenimiento habitual fuera del cuidado razonable y de la limpieza peri dica de la cesta colectora Si el sello del eje est gastado o averiado rep relo de la sigu iente manera Desensamblaje de la bomba Remoci n del sello viejo Desconecte la alimentaci n el ctrica al motor de la bomba A Aseg rese de que las v lvulas en las tuber as de as piraci n y de regreso est n cerradas antes de comenzar a trabajar Libere toda la presi n abriendo todos los orificios de ventilaci n antes de comenzar a trabajar 1 Drene la bomba sacando los tapones de drenaje en la parte inf
32. erior de la unidad de la bomba y de la unidad del colector 2 Verifique que no haya presi n en la unidad del colector saque la cubierta destornille girando hacia la izquierda 3 Saque las 6 tuercas las arandelas de fijaci n y las arandelas planas sujetando la plancha de estanqueidad a la unidad de la bomba Jale y saque la plancha de estanqueidad y el motor de la unidad de la bomba Puede ser necesario usar un destornillador CUIDADOSAMENTE para separar la unidad de la plancha de estanqueidad 4 Saque los siete tornillos y arandelas que sujetan el difusor a la plancha de estanqueidad Saque el difusor 5 Saque el techo del motor Teniendo cuidado de no tocar los bornes del capacitor afloje la abrazadera del capacitor y mu valo a un lado 6 Sostenga el eje con una llave abierta de 7 16 en los filos del eje del motor 7 Destornille el impulsor del eje gire hacia la izquierda frente al mismo AVISO En el modelo de 2 HP saque el tornillo del impulsor rosca izquierda gire hacia la derecha y la empaquetadura antes de sacar el impulsor Verifique que la empaquetadura no est averiada que no tenga rajaduras etc C mbiela si est averiada 8 Saque los cuatro tornillos que sostienen la plancha de es tanqueidad al motor 9 Coloque la plancha de estanqueidad boca abajo sobre una superficie plana y golpetee el asiento de cer mica para sacarlo Figura 7 10 Saque el deflector del eje del motor y verifique
33. g e Tighten Sta Rite trap lids to 30 ft Ibs 4 1 kg m torque for testing e Water pressure for test must be less than 25 PSI 7 5 kg cm e Water Temperature for test must be less than 1000 F 389 e Limit test to 24 hours After test visually check system to be sure it is ready for operation Remove trap lid and retighten hand tight only NOTICE These parameters apply to Sta Rite equipment only For non Sta Rite equipment consult manufacturer IMPORTANT SAFETY INSTRUCTIONS Always follow basic safety precautions with this equipment including the following 44 WARNING To reduce the risk of injury do not per mit children to use this product unless they are closely supervised at all times A CAUTION This pump is for use with permanently installed pools and may also be used with hot tubs and spas if so marked Do not use with storable pools A permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage A storable pool is con structed so that it may be readily disassembled for stor age and reassembled to its original integrity SAVE THESE INSTRUCTIONS INSTALLATION Only qualified licensed personnel should install pump and wiring Strainer basket cover Discharge port i Suction port lt Pump may be bolted to level foundation or mounting bracket Figure 1 NOTICE Port threa
34. hten screws to 10 14 inch lbs 11 2 16 1 kg cm torque Assemble motor and seal plate to pump body with nuts flat washers and lock washers Torque nuts to 120 130 in lbs 138 150 kg cm Prime pump according to instructions on Page 7 REPAIR PARTS LIST Box A Pkg 188 2 Slip 1 2 Union Kit Note that this kit includes both inlet and outlet connections Includes U11 200PS Union Collar Qty 2 U9 362 O Ring Qty 2 U11 196P 2 Slip Adapter Qty 2 Key Part MPRA6B 143L No Description Qty 1 3 HP 1 Motor 115 230V 1750 RPM 1 62003 2088 2 Screw 10 32x1 2 1 U30 692SS 3 Bonding Lug 1 U17 568 4 Slinger 1 17351 0009 5 Seal Plate 1 C3 184P 6 Seal Plate Cord Ring 1 U9 373 7 Shaft Seal 1 37400 00275 8 Impeller 1 C105 236PDA 8A O Ring Gasket 1 33455 1047 8B Impeller Screw 1 37337 6080 9 Diffuser 1 C1 270P 10 Diffuser O Ring 1 U9 374 11 Tank and Trap Body Only 1 C76 58P 12 Trap Cover 1 C3 185P 13 Trap Cover O Ring 1 U9 375 14 Trap Basket 1 C8 58P 15A Drain Plug 2 U178 920P 15B Mounting Screw 5 16 14x5 8 2 U30 919SS 16 Base 1 C4 77P 17 Motor Pad 1 C35 45 18 Screw 8 32x7 8 Rd Hd 7 U30 542SS 19 Lock Washer 8 Ext Tooth 7 U43 21SS 20 Flat Washer 3 8 6 U43 62SS 21 Lock Washer 3 8 6 U43 12SS 22 Nut 3 8 16 Hex nickel plated brass 6 71403 23 Cap Screws 3 8 16x1 Hex 4 U30 74SS Nameplate 1 32155 4071 Tag CAUTION This pump equipped with 1 U63 13 mechanical shaft seal
35. ing water from only one main drain that is there must be at least two main drains connected to the pump whenever it is running see Figure 2 However if two main drains run into a single suction line the single suction line may be equipped with a valve which will shut off both main drains from the pump see Figure 2 More than one pump can be connected to a single suc tion line as long as the requirements above are met Water Velocity The maximum water velocity through the suction fitting or cover for any suction outlet must be 1 5 feet per sec ond unless the outlet complies with the latest ASME ANSI Specification for Suction Fittings For Use in Swimming Pools Spas Hot Tubs and Whirlpool Bathtub Applications In any case do not exceed the suction fit ting s maximum designed flow rate If 100 of the pump s flow comes from the main drain system the maximum water velocity in the pump suction hydraulic system must be six feet per second or less even if one main drain suction outlet is completely blocked The flow through the remaining main drain s must com ply with the latest ASME ANSI Specification for Suction Fittings For Use in Swimming Pools Spas Hot Tubs and Whirlpool Bathtub Applications IAPMO Certified Anti entrapment Cover or Suction Fitting screw fastened to e Main Drain Sump Suction Outlet gt lt a gt lt Suction Outlet Main Drain Main Drain
36. ion and return piping are closed before starting work Release all pressure by opening all vents before starting work 1 Drain pump by removing drain plugs on bottom of pump body and trap body Be sure there is no pressure in trap body remove cover unscrew by turning counterclockwise Remove 6 nuts lockwashers and flat washers holding seal plate to pump body Pull seal plate and motor away from pump body You may have to CAREFULLY use a screwdriver to separate body from seal plate Remove seven screws and washers holding diffuser to seal plate Remove diffuser Remove motor canopy Being careful not to touch ca pacitor terminals loosen capacitor clamp and move capacitor to one side Hold shaft with 7 16 open end wrench on motor shaft flats Unscrew impeller from shaft turn counterclockwise when facing it NOTICE On 2 HP model remove impeller screw left hand thread turn clockwise and gasket before removing impeller Inspect gasket for damage cracks etc Replace if damaged Remove four screws holding seal plate to motor Place seal plate face down on flat surface and tap out ceramic seat Figure 7 Remove slinger from motor shaft and inspect for dam age or abrasion Clean seal cavity in seal plate and clean motor shaft Mechanical seal ceramic seat Figure 7 Pump Reassembly Installing New Seal ils Ceramic seat must be clean and free of d
37. irt grease dust etc Wet outer edge with small amount of liquid detergent press ceramic seat into seal plate cavity firmly and squarely with finger pressure Figure 8 Polished surfac Rubber S surface Figure 8 If ceramic seat will not locate properly remove it place face up on bench and reclean cavity Ceramic seat should now locate If seat still will not locate properly place a cardboard washer over the polished face and use a piece of 3 4 19mm standard pipe for pressing purposes NOTICE Be sure not to scratch or mar polished sur face or seal will leak Replace slinger on end of motor shaft so that impeller sleeve will push it into position If slinger shows signs of wear or damage replace it Remount seal plate on motor Tighten bolts to 60 80 inch lbs 69 92 kg cm torque Apply a small amount of liquid detergent to inside di ameter of rotating half of seal Slide rotating seal member polished carbon face out over impeller sleeve until rubber drive ring hits back of impeller NOTICE Be sure not to nick or scratch polished seal face seal will leak if face is damaged Screw impeller onto shaft clockwise this will auto matically locate seal in seal plate NOTICE On 2 and 2 1 2 HP models install impeller gasket and lock screw left hand thread turn coun terclockwise Torque lock screw to 50 55 inch Ibs 57 6 63 kg cm Mount diffuser on seal plate tig
38. ision AWARNING Fire and burn hazard Modern motors run at high temperatures To reduce the risk of fire do not allow leaves debris or foreign mat ter to collect around the pump motor To avoid burns when handling the motor let it cool for 20 minutes before trying to work on it An automatic in ternal cutoff switch protects the motor from heat damage Hazardous suction Can trap hair or body parts causing severe injury or death Do not block suction during operation Priming Pump Release all pressure from filter pump and piping system see the filter owner s manual In a flooded suction system water source higher than pump pump will prime itself when suction and dis charge valves are opened If pump is not in a flooded suction system unscrew and remove trap cover see Figure 5 fill trap and pump with water TO REMOVE OVERTIGHT Figure 5 Use a pry bar or board as shown to remove tight lid Do notuse a pry bar to tighten lid Clean and inspect O Ring reinstall on trap cover Do not lubricate the trap cover O Ring The original equipment O Ring contains a permanent internal lubri cant NOTICE If you replace the O Ring with a non internally lubricated O Ring you may need to apply a silicone based lubricant Replace trap cover on trap turn clockwise to tighten cover NOTICE Tighten trap cover by hand only no wrenches Pump should prime now Priming time will dep
39. ma cuando se abran las v lvulas de aspiraci n y de descarga Si la bomba no est en un sistema de aspiraci n inundado destornille y retire la cubierta del colector consulte la Figura 5 Ilene el colector y la bomba con agua PARA SACAR UNA TAPA DEMASIADO APRETADA Figura 5 Use una barra o una tabla de apalancar seg n se ilustra para sacar una tapa apretada No use una barra de apalancar para apretar la tapa Limpie e inspeccione el aro t rico vuelva a colocar la cubierta del colector No lubrique el aro t rico de la cubierta del sif n El aro t rico origi nal de la m quina contiene un lubricante interno permanente AVISO Si reemplaza el aro t rico con uno sin lubricaci n interna es posible que necesite aplicar un lubricante a base de silicona Vuelva a colocar la cubierta del colector en el colector gire hacia la derecha para apretar la cubierta AVISO Apriete la cubierta del colector a mano solamente sin llaves de tuerca Ahora la bomba se deber cebar El tiempo de cebado depender del largo vertical de la altura de aspiraci n y del largo horizontal de la tuber a de aspiraci n Si la bomba no ceba verifique que todas las v lvulas est n abiertas que el extremo de la tuber a de aspiraci n se encuentre debajo del agua que la bomba no est tratando de levantar agua a m s de 5 pies 1 5 m de altura y que no haya fugas en la tuber a de as piraci n Consulte la Gu a para la Locali
40. motor Electrical 10 Pump may be running too slowly check voltage at motor terminals and at meter while pump is run ning If low see wiring in structions or consult power company Check for loose connections Pump may be too hot A Check line voltage if less than 90 or more than 110 of rated voltage consult a licensed electrician Increase ventilation Aw Reduce ambient temperature D Tighten any loose connections MECHANICAL TROUBLES AND NOISE 1 If suction and discharge piping are not adequately supported pump assembly will be strained See Installation Page 3 2 Do not mount pump on a wooden platform Securely mount on concrete platform for quietest performance STA RITE LIMITED WARRANTY Pumps filters skimmers underwater lights excluding bulbs ac cessories and fittings manufactured by Sta Rite are warranted to be free of defects in material and or workmanship for one 1 year from the original date of installation The foregoing warranties relate to the original consumer purchaser Purchaser only Sta Rite Industries shall have the option to re pair or replace the defective product at its sole discretion Purchasers must pay all labor and shipping charges necessary to replace the product covered by this warranty Requests for war ranty service must be made through the installing dealer This war ranty shall not apply to any product that has been subject to
41. n lugar se guro y conveniente para su informaci n Para obtener informaci n t cnica sobre este producto comun quese con el instalador o llame a Sta Rite al 262 728 9181 Visite www staritepool com para obtener m s informaci n sobre los productos Sta Rite indicados arriba para ubicar un concesionario de Sta Rite cercano a usted PARA CREAR UN REGISTRO DE SU GARANT A CON STA RITE e Llene un registro de garant a en www staritepool com pulsando en Registro de Productos y seleccionando Albercas Sta Rite O STA RITE yA e Llene la porci n inferior y enviela por correo dentro de los 10 d as de la instalaci n a Sta Rite Attn Warranty Dept Departamento de Garant a 293 Wright St Delavan WI 53115 Tarjeta de registro de garant a Nombre Nueva Instalaci n Reemplazo Direcci n A os de servicio de la alberca menos de 1 1 3 3 5 5 10 Ciudad Estado C digo postal Zip Este producto se compr en Fecha de instalaci n o de compra Nombre de la empresa Producto adquirido Direcci n N mero de modelo Ciudad Estado C digo postal Zip S4877PS Rev 5 28 04 MPRA SERIES PUMP WITH TRAP To avoid unneeded service calls prevent possible in juries and get the most out of your pump READ THIS MANUAL CAREFULLY The Sta Rite MPRA Series Self priming Centrifugal pump e Is designed for use wi
42. o Chicago Illinois PUMP SUCTION REQUIREMENTS Pump suction is haz ardous and can trap and drown or disembowel bathers Do not use or operate swim ming pools spas hot tubs or water features if a suction out let cover is missing broken or loose Follow the guidelines y below for a pump installation Hazardous suction which minimizes risk to users Can trap hair or of pools spas hot tubs and body parts causing water features severe injury or death Do not block suction 44 DANGER Entrapment Protection The pump suction system must provide protection against the hazard of suction entrapment or hair entrapment entanglement Suction Outlet Covers All suction outlet covers must be maintained They must be replaced if cracked broken or missing See Page 5 for outlet cover certification requirements All suction outlets must have correctly installed screw fas tened covers in place A IAPMO Certified Anti entrapment Cover or Suction Fitting screw fastened to Main Drain Sump At Least 3 Feet No valves between Tee and Main Drains Suction Outlets Per Pump Figure 2 Provide at least two hydraulically balanced main drains with covers as suction outlets for each circulating pump suction line The centers of the main drains suction outlets on any one suction line must be at least three feet apart The system must be built so that it cannot operate with the pump draw
43. oltios graduaci n de f brica a 115 voltios 1 Si usted tiene una tensi n de suministro del motor de 230 voltios verifique que la ficha est configurada para 230 voltios La flecha en la ficha indicar a la posici n de 230 voltios Observe que la ficha s lo se puede conectar con una de las puntas en esta posici n 2 Si tiene un suministro de 115 voltios empuje la ficha direc tamente hacia arriba y col quela en las dos puntas de lat n seg n se ilustra NOTA La flecha est realzada para mayor claridad A cl Figura 4B Ficha de cam bio de voltaje configurada para 115 Voltios Figura 4A Ficha de cam bio de voltaje configurada para 230 Voltios TABLA I INFORMACION SOBRE LOS FUSIBLES Y LOS CABLES RECOMENDADOS Servicio al motor distancia en pies metros Tama o AWG del cable mm HP Branch fuse Max Load Voltaje 0 100 101 200 201 300 Modelo del motor rating amps Amps Hz Fase 0 30 30 60 60 90 MPRA6B 143L 1 3 15 15 4 2 2 1 115 230 60 1 14 14 2 2 14 14 2 2 12 14 3 2 SURE A 230 60 14 2 2 14 2 2 14 3 2 Se recomienda usar fusibles temporizados en lugar de fusibles estandar en cualquier circuito de motor OPERACI N AVISO NUNCA haga marchar la bomba en seco ya que eso puede da ar los sellos provocando fugas e inundaciones Llene la bomba con agua antes de encender el motor A ADVERTENCIA Antes de retirar la cubierta del colector 1 DETENGA LA BOMBA an
44. ous may fail causing severe injury or property pressure damage Read and follow instructions in owner s manual when installing and operating equipment Have a trained pool professional perform all pressure tests 1 Do not connect system to a high pressure or city water system 2 Use equipment only in a pool or water feature installation 3 Trapped air in system can cause explosion BE SURE all air is out of system before operating or testing equipment Before pressure testing make the following safety checks e Check all clamps bolts lids and system accessories before testing e Release all air in system before testing e Tighten Sta Rite trap lids to 30 ft Ibs 4 1 kg m torque for testing e Water pressure for test must be less than 25 PSI 7 5 kg cm e Water Temperature for test must be less than 1000 F 389 e Limit test to 24 hours After test visually check system to be sure it is ready for operation Remove trap lid and retighten hand tight only NOTICE These parameters apply to Sta Rite equipment only For non Sta Rite equipment consult manufacturer IMPORTANT SAFETY INSTRUCTIONS Always follow basic safety precautions with this equipment including the following 44 WARNING To reduce the risk of injury do not per mit children to use this product unless they are closely supervised at all times A CAUTION This pump is for use with permanently installed pools
45. pipe directly to pump use Teflon tape or Plasto Joint Stik to seal connections Do not use pipe dope pipe dope causes cracking in some plas tics and may damage components in piping system When connecting pipe to pump with union half use Teflon tape or Plasto Joint Stik between pipe and union adapter Union collar to pump should be assembled dry and hand tight NOTICE Pump suction and discharge connections have molded in thread stops DO NOT try to screw pipe in be yond these stops Teflon Taping Instructions Use only new or clean PVC pipe fittings Wrap male pipe threads with one to two layers of Teflon tape Cover entire threaded portion of pipe Do not overtighten or tighten past thread stop in pump port If leaks occur remove pipe clean off old tape rewrap with one to two additional layers of tape and remake the connection NOTICE Support all piping connected with pump Piping Use at least 2 51 mm pipe Increase size if a long run is needed To avoid strains on the pump support both suction and discharge pipes independently Place these supports near the pump To avoid a strain left by a gap at the last connection start all piping at the pump and run pipe away from the pump To avoid airlocking slope suction pipe slightly upward toward the pump NOTICE To prevent flooding when removing pump for service all flooded suction systems must have gate valves in suction and discharge pipes Lake Chemical C
46. r manufacturer s instructions for reactiva tion of the filter 3 Inspect all electrical wiring for damage or deterioration over the shutdown period Have a qualified service man repair wiring as needed Inspect and tighten all watertight connections Open all valves in suction and return piping Remove any winterizing plugs in piping system Drain all antifreeze from system CON D a A Close all drain valves and replace all drain plugs in piping system 9 Prime pump according to instructions on Page 7 PUMP SERVICE A WARNING Pump should only be serviced by qualified personnel For best results use only gen uine Sta Rite factory parts Be sure to prime pump Page 7 before starting A CAUTION Before removing trap cover 1 STOP PUMP before proceeding 2 CLOSE GATE VALVES in suction and discharge pipes 3 RELEASE ALL PRESSURE from pump and piping system Hazardous voltage Can shock burn or cause death Disconnect power before working on pump or motor To avoid dangerous or fatal electrical shock haz ard turn OFF power to motor before working on pump or motor Aside from lubricating trap cover O Ring no lubrication or regular maintenance is needed beyond reasonable care and periodic cleaning of strainer basket If shaft seal is worn or damaged repair as follows Pump Dissasembly Removing Old Seal Disconnect power to pump motor A Be sure valves on suct
47. safety alert symbol When you see this symbol on your system or in this manual look for one of the following signal words and be alert to the po tential for personal injury ACES Warns about hazards that will cause death serious personal injury or major property damage if ignored AWARNING warns about hazards that can cause death serious personal injury or major property damage if ignored A CAUTION warns about hazards that will or can cause minor personal injury or property damage if ignored NOTICE indicates special instructions not related to hazards Carefully read and follow all safety instructions in this manual and on equipment Keep safety labels in good condition replace if missing or damaged AWARNING Incorrectly installed or tested equipment Hazardous may fail causing severe injury or property pressure damage Read and follow instructions in owner s manual when installing and operating equipment Have a trained pool professional perform all pressure tests 1 Do not connect system to a high pressure or city water system 2 Use equipment only in a pool or water feature installation 3 Trapped air in system can cause explosion BE SURE all air is out of system before operating or testing equipment Before pressure testing make the following safety checks e Check all clamps bolts lids and system accessories before testing e Release all air in system before testin
48. salidas de as piraci n Se deber n reemplazar en caso de que est n rajadas rotas o ausentes Consulte la p gina 5 para obtener informaci n sobre los requer imientos de certificaci n de las cubiertas para las salidas Todas las salidas de aspiraci n deben contar con cubiertas de bidamente instaladas y atornilladas en su lugar Cubierta o Accesorio de Aspiraci n anti enredos certificado por IAPMO atornillado al colector del drenaje principal N M nimo 3 pies No hay v lvulas entre el Te y los Drenajes principales Salidas de aspiraci n por bomba Figura 2 Proporcione al menos dos drenajes principales hidr ulicamente equilibrados con cubiertas como salidas de aspiraci n para cada l nea de aspiraci n de la bomba de circulaci n Los centros de los drenajes principales salidas de aspiraci n en cualquiera de las l neas de aspiraci n deben estar al menos a tres pies de distancia entre s Es necesario construir el sistema de manera que no pueda fun cionar si la bomba extrae agua solamente de un drenaje principal es decir que deben haber al menos dos drenajes principales conectados a la bomba siempre que est funcionando consulte la Figura 2 Sin embargo si dos drenajes principales corren hacia una sola l nea de aspiraci n la l nea de aspiraci n singular puede estar equipada con una v lvula que cierre ambos drenajes princi pales desde la bomba consulte la Figura 2 Se puede conec
49. st be not more than 10 above or below motor nameplate rated voltage or motor may over heat causing overload tripping and reduced component life If voltage is less than 90 or more than 110 of rated voltage when motor is running at full load consult power company Grounding Bonding Install ground bond and wire motor according to local or National Electrical Code requirements Permanently ground motor Use green ground terminal provided under motor canopy or access plate See Figure 3 use size and type wire required by code Connect motor ground terminal to electrical service ground Bond motor to pool structure Use a solid copper conductor size No 8 AWG 8 4 sq mm or larger Run wire from exter nal bonding lug see Figure 3 to reinforcing rod or mesh Connect a No 8 AWG 8 4 sq mm solid copper bonding wire to the pressure wire connector provided on the motor housing and to all metal parts of the swimming pool spa or hot tub and to all electrical equipment metal piping or conduit within 5 feet 1 5 m of the inside walls of swimming pool spa or hot tub Bonding Figure 3 Typical ground screw and bonding lug locations Wiring NOTICE 3 phase models require magnetic motor starters and external overload protection If in doubt about the procedure consult a licensed electrician Pump must be permanently connected to circuit Table I Page 6 give correct wire and circuit breaker sizes for the pump alon
50. ta de Tefl n o Plasto Joint Stik para sellar las conexiones No use compuesto para tubos ya que ste provoca rajaduras en ciertos pl sticos y puede da ar los componentes del sistema de tubos Cuando conecte el tubo a la bomba con una mitad de uni n use cinta de Tefl n o Plasto Joint Stik entre el tubo y el adapta dor de la uni n El collar n de uni n a la bomba se debe ensam blar en seco y apretar a mano AVISO Las conexiones de aspiraci n y de descarga tienen topes de rosca moldeados NO trate de atornillar una tuber a m s all de estos topes Instrucciones para la aplicaci n de cinta de Tefl n Use s lo accesorios para tubos de PVC nuevos o limpios Envuelva las roscas macho de los tubos con una o dos capas de cinta de Tefl n Cubra toda la porci n fileteada del tubo No apriete demasiado ni m s all del tope de rosca en el orifi cio de la bomba Si observa fugas saque el tubo limpie la cinta vieja vuelva a envolverlo con una o dos capas adicionales de cinta y vuelva a establecer la conexi n AVISO Soporte todos los ca os conectados a la bomba Tuber as Use un tubo de al menos 2 51 mm Aumente el tama o si necesita un trayecto largo Para evitar demasiado esfuerzo sobre la bomba soporte la tu ber a de aspiraci n y de descarga en forma independiente Coloque estos soportes cerca de la bomba Para evitar el esfuerzo debido a una brecha en la ltima conex i n comience toda l
51. tar m s de una bomba a una sola l nea de as piraci n siempre que se cumplan los requerimientos indicados en el p rrafo que precede Velocidad del agua La m xima velocidad del agua a trav s del accesorio de as piraci n o de la cubierta para cualquier salida de aspiraci n debe ser de 1 5 pies por segundo a menos que la salida cumpla con la versi n m s reciente de la Especificaci n de ASME ANSI para Accesorios de Aspiraci n que se usen en Albercas Jacuzzis Ba os termales y Piscinas de Hidromasaje En todo caso no sobrepase el caudal m ximo designado para el acceso rio de aspiraci n Si el 100 del flujo de la bomba se origina en el sistema de drenaje principal la m xima velocidad del agua en el sistema hidr ulico de aspiraci n de la bomba debe ser de seis pies por segundo o menos a n en el caso en que uno de los drenajes principales salidas de aspiraci n est completamente blo queado El flujo a trav s del de los desag e s principal es restante s deber cumplir con la versi n m s reciente de la Especificaci n de ASME ANSI para Accesorios de Aspiraci n que se usen en Albercas Jacuzzis Ba os termales y Piscinas de Hidromasaje Cubierta o Accesorio de Aspiraci n anti enredos certificado por IAPMO atornillado al colector del drenaje principal Salida de aspiraci n gt lt Drenaje principal gt i Salida de aspiraci n Drenaje principal
52. tes de continuar 2 CIERRE LAS V LVULAS DE COMPUERTA en las tuber as de aspiraci n y de descarga 3 LIBERE TODA LA PRESI N de la bomba y del sistema de tuber a A Si la bomba est pasando una prueba de presi n veri fique que se haya liberado la presi n antes de retirar la cubierta del sif n No bloquee la aspiraci n A ADVERTENCIA A de la bomba Si se bloquea con el cuerpo puede provocar lesiones graves o fatales Cuando ni os peque os usen la alberca es importante que SIEM PRE est n bajo la estricta super visi n de un adulto n l A ADVERTENCIA Peligro Aspiraci n peligrosa de incendio y quemaduras Los Puede atrapar el motores modernos funcionan a cabello o partes del altas temperaturas Para reducir cuerpo provocando el peligro de incendio no per lesiones graves o mita que hojas escombros o muerte part culas extra as se acumulen alrededor del motor de la bomba Para evitar quemaduras cuando se trabaje con el motor deje que ste se enfr e durante unos 20 minutos antes de manipularlo Un interruptor interno de corte autom tico protege al motor contra da os t rmicos durante su funcionamiento Cebado de la bomba Libere toda la presi n del filtro de la bomba y del sistema de tu ber a consulte el manual del propietario No bloquee la aspiraci n En un sistema de aspiraci n inundado la fuente de agua est a un nivel m s alto que la bomba la bomba se cebar por s mis
53. th water features or as a centrifugal pump e Is an excellent performer durable reliable Table of Contents Safety INStrUCtIONS occccoooooooooccnononocononnnnnonnnnnnnncnonininnnns 2 sta hati OM iras id 3 Pool Pump Suction Requirements cceeeeereeeeees 4 5 A O 5 6 OPeratiON seorsan ticas cs 7 Storage Winterizing ocoooooonccnnnnnoocccnnonnancnnononnncncnnnnnos 7 8 PUM Pr SERVICE elirus lane 8 10 Repair Parts List s 2 s 2ssdeveseevsinaraeassavevertnaneanseanararestaneae 10 Troubleshooting Guide cccccceeeeeerececeeeeeeeeeeeeneees 11 WAITANLY sanos 12 READ AND FOLLOW SAFETY INSTRUCTIONS This is the safety alert symbol When you see this symbol on your system or in this manual look for one of the following signal words and be alert to the po tential for personal injury ACES Warns about hazards that will cause death serious personal injury or major property damage if ignored AWARNING warns about hazards that can cause death serious personal injury or major property damage if ignored A CAUTION warns about hazards that will or can cause minor personal injury or property damage if ignored NOTICE indicates special instructions not related to hazards Carefully read and follow all safety instructions in this manual and on equipment Keep safety labels in good condition replace if missing or damaged AWARNING Incorrectly installed or tested equipment Hazard
54. zaci n de Fallas P gina 11 Almacenamiento Preparaci n para el invierno AVISO Si permite que la bomba se congele la bomba sufrir da os y la garant a quedar anulada AVISO No use soluciones anticongelantes excepto propilengli col en su sistema de alberca jacuzzi El propilenglicol anticon gelante RV no es t xico y no da ar los componentes pl sticos del sistema otros anticongelantes son muy t xicos y pueden da ar los componentes pl sticos en el sistema Drene toda el agua de la bomba y de la tuber a cuando espere temperaturas heladas o cuando guarde la bomba por un tiempo prolongado consulte las instrucciones a continuaci n Mantenga el motor seco y cubierto durante el almacenamiento Para evitar problemas de condensaci n corrosi n no cubra la bomba con pl stico Para instalaciones no protegidas al exterior 1 Encierre todo el sistema en un recinto a prueba de la intemperie 2 Para evitar da os debido a condensaci n corrosi n aseg rese de que haya ventilaci n no envuelva el sistema en pl stico 3 Use una soluci n de 40 propilenglicol 60 agua para proteger la bomba a temperaturas de 50 F 46 C Drenaje de la bomba A ADVERTENCIA Peligro de explosi n La purga del sis tema con aire comprimido puede hacer que explote con el peligro de lesiones graves o muerte a cualquiera que se encuen tre cerca Use s lo un soplador de gran volumen a baja presi n

Download Pdf Manuals

image

Related Search

Related Contents

Instrucciones de manejo  MDG Link for Microsoft Visio User Guide  CP 30sc - 120 Service Manual  Manual de Instalación y Operación Gabinete Multi    Sistema de Mini- Componente de Alta Fidelidad  Envision Peripherals L26W761 User's Manual  Samsung Galaxy Tab 4 (10.1) Felhasználói kézikönyv(LL)  UDパンフ2012PDF用.tp3  Samsung SGH-E810 คู่มือการใช้งาน  