1. Commutateur RVMS Interruptor RVMS 509267 9EN CIM Pump Pompe Bomba STEP 4 Plumb vent Plumb vent using 2 threaded pipe to fitting in basin cover Use pipe joint compound on threads and hand tighten only on plastic fittings The basin must be vented in accordance with state and local codes The vent is essential for proper switch operation and must not be omitted or restricted CAUTION Do not use a mechanical vent with this product A mechanical vent will cause improper operation of the automatic switch STEP 5 Test unit Connect power cord to electrical supply as stated under Electrical Connections Secure power cord to piping with ties or tape Fill unit with water through inlet Pump should turn on with 7 10 of water in tank and turn off when 2 5 of water is left in tank MAINTENANCE Maintenance operations consist of cleaning basin and limited pump mainte nance WARNING Before any maintenance is performed shut off water inlet and disconnect power cord from electrical supply outlet Pump may become hot in operation Allow pump to cool before servicing BASIN Sediment may build up in basin causing pump to operate improperly Remove 10 1 4 20 screws from cover Remove cord grommet and loosen cords to allow slack and then remove cover Remove pump and clean basin using a mild detergent and water Reassemble in reverse order Torque screws 18 20 in lbs PUMP Sediment or lint can clog pump and cause impr
2. check valve and union basin cover has 1 1 2 FNPT fitting 3 Vent piping basin cover has 2 FNPT fitting and 2 union SAFETY GUIDELINES H AWARNING A 1 CAUTION Make certain that the unit is disconnected from the power source before attempting to service or rework any components 2 Read all instructions and safety guidelines thoroughly Failure to follow the guidelines and the instructions could result in serious bodily injury and or property damage 3 Check local electrical and building codes before installation The installa tion must be in accordance with their regulations During normal operation the pump is immersed in water Caution must be used to prevent bodily injury when working near the pump a The plug must be removed from the receptacle prior to touching servic ing or repairing the pump b To minimize possible fatal electrical shock hazard extreme care should be used when changing fuses Do not stand in water while changing fuses or insert your finger into fuse socket ELECTRICAL CONNECTIONS All wiring must meet local codes and a licensed electrical contractor is rec ommended The pump is supplied with a 3 prong vented plug Plugs must be plugged into a grounded receptacle and should be on a separate circuit with fuse or circuit breaker and GFCI ground fault circuit interrupter Be sure AUTOMATIC OPERATION FONCTIONNEMENT AUTOM ATIQUE FUNCIONAMIENTO AUTOMITICO Grounded Receptacle i REceptac
3. del motor No use una extensi n Si la bomba se instala en un s tano la conexi n de enchufe debe estar a cuatro pies o m s por encima del nivel del piso especialmente si el s tano se inunda Aseg rese de que las conexiones el ctricas no puedan ser alcanzadas por la subida de las aguas En ninguna circunstancia debe estar ubicado el tomacorriente donde el agua lo pueda inundar o sumergir INSTALACION Toda la plomer a debe cumplir con los c digos locales Es recomendable emplear para el trabajo a un contratista de plomer a licenciado A todos los accesorios conectados al Conjunto de Dep sito WRS 9EN se les deben hacer respiraderos conforme a los c digos estatales y locales PASO 1 Determine la ubicaci n apropiada para la unidad La unidad debe estar ubicada de manera que la admisi n de la bomba sea alimentada por gravedad La unidad no absorber agua de un nivel inferior Coloque y nivele el dep sito Mantenga el dep sito lejos de cualquier cosa que lo pueda perforar La posici n elegida debe ser conveniente para la toma de agua de la bomba para la toma de descarga para la ventilaci n de la tuber a y para el suministro de corriente PASO 2 Conecte la toma de agua Utilice una tuber a de 1 1 2 roscada conecte la toma a la conexi n de la cubierta del dep sito Utilice un sif n P For technical assistance please contact y una uni n junto al dep sito Use compuesto de uni n de tuber as y apriete solamente a mano
4. las conexiones de pl stico No reduzca la conexi n por debajo de un di metro de tuber a de 1 1 2 PASO 3 Nivele la descarga Con un tubo roscado de 38 1 mm 1 1 2 pulg nivele la descarga al accesorio de la tapa de la cubeta Se recomienda el uso de una v lvula de retenci n para evitar el reflujo del agua al sumidero Instale la v lvula de retenci n tan cerca de la parte superior de la cubeta como sea posible para evitar el ciclo de la bomba Aseg rese de instalar la v lvula de retenci n en la direcci n correcta del flujo Si se instala la v lvula de reten ci n al rev s no saldr agua de la unidad Aseg rese de sellar la tuber a de descarga con compuesto para juntas de tuber a y de no exceder la altura de elevaci n de la bomba S lo apriete los accesorios de pl stico a mano PASO 4 Conecte el respiradero Utilice una tuber a de 2 roscada para conectar el respiradero a la conexi n en la cubierta del dep sito Use compuesto de uni n de tuber as en las roscas y apriete solamente a mano las conexiones pl sticas El dep sito debe tener un respiradero conforme a los c digos estatales y locales PRECAUCION No use un respiradero mec nico con este producto Un respiradero mec nico causar que el interruptor autom tico funcione mal PASO 5 Pruebe la unidad Conecte el cable de corriente al tomacorriente como se instruye en la secci n Conexiones El ctricas Asegure el cable de corriente a la tuber a con amarre
5. ISSEMENT Tous les branchements doivent satisfaire les codes locaux de plus il est recommand de faire appel un lectricien agr La pompe comprend une fiche trois branches Cette fiche doit tre raccord e une prise mise la terre et le tube d a ration doit tre libre afin d assurer le bon fonctionnement de la pompe La pompe devrait tre branch e un circuit ind pendant avec fus ible ou disjoncteur ainsi qu un GFI interrupteur de mise la terre S assurer que l alimentation lectrique correspond aux donn es de la plaque signal tique Ne pas utiliser de rallonge Si la pompe est install e dans un sous sol la connex ion lectrique doit se faire au moins quatre pieds du niveau du sol particuli re ment si le sous sol risque d tre inond S assurer que l eau ne peut atteindre le niveau des connexions Le bo tier ou la prise de courant ne devrait jamais se trouver endroit o il pourrait tre submerg INSTALLATION Toute la tuyauterie doit satisfaire aux normes locales Il est recommand de faire appel un plombier qualifi pour l installation Tous les raccords bran ch s l ensemble de r servoir WRS 9EN doivent tre a r s conform ment aux normes locales et provinciales TAPE 1 D terminer l emplacement de la pompe Elle devrait tre plac e de mani re ce que l entr e soit aliment e par gravit La pompe ne peut aspirer l eau se trouvant un niveau inf rieur Tenir le r
6. Litte GIANT Franklin Electric Co Inc Oklahoma City OK 73157 2010 www LittleGiantPump com customerservice lgpc com WRS 9EN WASTEWATER REMOVAL SYSTEM TEN MI ER 1e 101eznp1e Little Giant Wastewater Kits are carefully packaged inspected and tested to ensure safe operation and delivery When you receive your unit examine it carefully to determine that there are no missing broken or damaged parts that may have occurred during shipment If damage has occurred make notation and notify the firm you purchased the unit from They will assist you in replacement or repair if required Read this manual carefully and also the enclosed pump manual This unit is designed to pump wastewater from laundry trays washing machines sinks or dehumidifiers The unit is not designed to pump raw sewage or flu ids other than water The unit is capable of removing fluids with solids up to 3 4 spherical Maximum fluid temperature is 125 F The unit is designed to fit under most sinks so in many cases it is not necessary to recess the unit into the floor ITEMS TO PURCHASE NOTE Some state or local codes require all electrical and or plumbing con nections to be made by a licensed contractor It is the customer s responsibility to determine codes involved and to comply with these codes If user can install unit items to purchase are 1 Inlet piping with trap and union basin cover has 1 1 2 FNPT fitting 2 Discharge piping with swing
7. au d a ration au raccord du couvercle du r servoir Utiliser de la p te joints sur les filets et ne serrer les raccords de plastique qu la main Le r servoir doit tre a r conform ment aux normes locales et provinciales MISE EN GARDE Ne pas utiliser d a ration m canique avec ce produit une telle m thode causerait un mauvais fonctionnement de l interrupteur TAPE 5 Tester la pompe Brancher le fil d alimentation une fiche lectrique tel qu indiqu la section Branchements lectriques Fixer le fil d alimentation aux tuyaux avec des attaches ou du ruban adh sif Remplissez la pompe d eau par l entr e La pompe devrait s allumer lorsque le niveau d eau dans le r servoir est de 7 10 cm et s teindre lorsqu il est 2 5 cm ENTRETIEN Les op rations d entretien consistent nettoyer le bassin et en un entretien lim it de la pompe AVERTISSEMENT Avant d effectuer toute forme d entretien fermer la prise d eau et d brancher le cordon d alimentation de la source d alimentation lectrique La pompe pourrait chauffer pendant son utilisation Laisser la pompe refroidir avant d effectuer son entretien BASSIN Des s diments peuvent s accumuler dans le bassin et entra ner un mauvais fonctionnement de la pompe Enlever les dix 10 vis 1 4 20 du cou vercle D poser l illet de cordon et desserrer les cordons pour laisser du jeu lors de la d pose du couvercle D poser la pompe et nettoyer le bassin avec u
8. d assurer la s curit de fonctionnement et une livraison en bonne condition la r ception de votre appareil le v rifier attentivement pour d terminer si des pi ces manquent ou ont t endommag es lors du transport Si c est le cas prendre note de tout dommage survenu et aviser l entreprise qui vous l a vendu Si une r paration ou un remplacement est requis elle vous pr tera assis tance Lire attentivement ce manuel en plus du manuel pour la pompe qui est inclus Cet appareil est con u pour pomper des eaux us es des bacs laver des laveuses des viers ou des d shumidificateurs L appareil n est pas con u pour pomper des eaux d gout brutes ou des fluides autres que de l eau L appareil peut vacuer des liquides contenant des solides sph riques pouvant atteindre un diam tre de 3 4 po La temp rature maximale du liquide est de 52 C 125 F L appareil est con u pour s adapter sous la plupart des viers il est donc rare ment n cessaire d installer l appareil en retrait dans le plancher ARTICLES SE PROCURER REMARQUE Certains codes locaux ou provinciaux exigent que tous les rac cordements lectriques et de plomberie soient effectu s par un entrepreneur qualifi Il incombe au client de d terminer si les codes de sa localit imposent de telles obligations et de s y conformer le cas ch ant Si l utilisateur est auto ris installer l appareil il doit se procurer les articles suivants 1 Tuyaute
9. lastic fittings Do not reduce below 1 1 2 piping STEP 3 Plumb discharge Using 1 1 2 threaded pipe plumb discharge to basin cover fitting Use of a check valve is recommended to prevent backflow of water into sump Install check valve as close to the top of the basin as possible to prevent cycling of pump Be sure check valve is installed in proper flow direction If check valve is installed backwards no water will flow out of unit Be sure the discharge piping is sealed with pipe joint compound and the lift height of pump is not exceeded Hand tighten only on plastic fittings Figure 2 MN AN i AA LI 2 DOS mua z O Y A L753 DESCRIPTION QUANTITY NOMENCLATURE QUANTITE DESCRIPCION CANTIDAD ITEM PART NO RTICLE N DE PIECE z ARTICULO NO DE PIEZA Cord Grommet Cordon Oeillet Cable Anillo Protector 113130 Cover Basin Couvercle Bassin Cubierta Cubeta Seal Ring Nitrile e Anneau de cachet Nitrile 924069 Anillo del sello Nitrilo 109310 Discharge Pipe Refoulement Tuyau Descarga Tubo Basin Bassin Cubeta Coupling Pipe Tuyau de Raccordement Tubo de Acople Adaptor Discharge Adaptateur Evacuation e Adaptador Descarga Screw Machine 1 4 20 x 1 2 Vis M canique 1 4 20 x 1 2 po Tomillo M quina 1 4 20 x 1 2 pulg O Ring Nitrile Joints toriques Nitrile e Junta torica Nitrilo 599261 Switch RVMS
10. le de Mis la Terre Recept culo Conectado a Tie rra Automatic Switch Power Cord with piggyback plug Cordon d alimentation Avec Interrupteur Automatique avec prise mixte Cable de AlimentaciUn Para Interruptor Autom tico con enchufe incorporad o Pump Power Cord C ble d Alimentation de la Pompe Cable de AlimentaciUn de la Bomba Figure 1 electrical supply matches pump nameplate data Do not use extension cord If installed in basement plug connection should be 4 or more above floor espe cially if basement floods Be sure electrical connections cannot be reached by rising water Under no circumstances should outlet box or receptacle be located where it may become flooded or submerged by water INSTALLATION All plumbing must meet local codes A licensed plumbing contractor is recom mended All fixtures connected to the WRS 9EN Basin Kit must be vented accord ing to state and local codes STEP 1 Determine proper location for unit Unit should be located so that inlet is gravity fed Unit will not draw water up from a lower level Position and level basin Keep basin away from any item that could puncture basin The position selected for the basin should be convenient to inlet discharge and vent piping and electrical supply STEP 2 Plumb inlet Using 1 1 2 threaded pipe plumb inlet to basin cover fitting Use a P trap and a union next to the basin Use pipe joint compound and hand tighten only on p
11. lva a instalarlos Vea el manual de la bomba para obtener otra informaci n Para cualquier otra reparaci n de la bomba devuelva la bomba a un centro de servicio autorizado de Little Giant PARA OBTENER INFORMACI N SOBRE LA SOLUCI N DE PROBLEMAS VEA EL MANUAL DEL PROPIETARIO INCLUIDO CON EL JUEGO PARA CUBETA WRS 9EN Instrucciones para el reemplazo del interruptor para la bomba RVMS interruptor mec nico vertical y remoto n mero 599261 PASO 1 PRECAUCI N Aseg rese de que la unidad est desconectada de la fuente de energ a antes de realizar cualquier servicio t cnico o cambiar cualquier componente PASO 2 Desconecte la unidad del tubo de entrada tubo de ventilaci n y tubo de descarga PASO 3 Quite los 14 tornillos de m quina Figura 2 elemento 8 que est n alrededor de la tapa de la cubeta PASO 4 Quite la tapa de la cubeta y el ojal del cable Figura 2 elemento 1 PASO 5 Quite el cable del interruptor para la bomba RVMS del ojal del cable PASO 6 Afloje la abrazadera de acero inoxidable que sujeta el interruptor para la bomba RVMS al tubo de descarga Figura 2 elemento 4 PASO 7 Deslice el interruptor para la bomba RVMS hacia arriba para quitarlo del tubo de descarga Aseg rese de recordar la orientaci n del interruptor para el reensamblado PASO 8 Corte 31 75 mm 1 25 pulg de la base del interruptor para la bomba RVMS como se detalla en la Figura 4 Ponga el ojal de goma aproximadamente a 38 1 mm 1 5
12. n d tergent doux et de l eau Assembler dans l ordre inverse Serrer les vis un couple de 2 03 2 25 Nm 18 20 po Ib POMPE Des s diments ou de la peluche peuvent obstruer la pompe et entra ner un mauvais fonctionnement Au besoin enlever la pompe du bassin et d visser les vis qui maintiennent la plaque d appui et la grille au bo tier du moteur D poser la plaque d appui et la grille pour nettoyer le passage du rotor et de la volute Ne pas utiliser de solvant fort sur le rotor Nettoyer avec un d tergent doux et de l eau puis r installer Consulter le manuel de la pompe pour obtenir plus d informations Pour toute autre r paration sur la pompe la retourner un centre de service autoris de Little Giant POUR OBTENIR DES INFORMATIONS DE D PANNAGE CONSULTER LE MANUEL DE L UTILISATEUR DE LA POMPE INCLUS AVEC L ENSEMBLE DE BASSIN WRS 9EN Instructions pour le remplacement de l interrupteur flotteur m canique vertical de la pompe RVMS no de cat 599261 TAPE 1 MISE EN GARDE S assurer que l appareil est d branch de sa source d alimentation avant d en effectuer l entretien ou de remettre en tat un composant TAPE 2 D brancher l appareil du tuyau d amen e d air du tuyau de ventila tion et du tuyau d vacuation TAPE 3 D poser les 14 vis m caniques Figure 2 article n 8 du pourtour du couvercle du bassin TAPE 4 Retirer le couvercle du bassin et enlever l illet de cordon Fig
13. ncluye un adaptador liso de 1 1 2 x 2 MNPT para ventilaci n de 1 1 2 Inlet of Basin is 1 1 2 FNPT L Arriv e de Cuvette est 1 1 2 FNPT Entrada de Palangana es 1 1 2 FNPT 2 slip X 1 1 2 MNPT adapter provided Use if required Un adaptateur a glissement de 2 x 1 1 2 MNPT est fourni Incluye un adaptador liso de 2 x 1 1 2 MNPT por si es requerido JEH 2 Union 2 po Raccord 2 Uni n On Level 7 10 e Marche 7 10 e En el Nivel 7 10 Off Level 2 5 e Arr t 2 5 e Del Nivel 2 5 Figure 4 ltem No Article Articulo Rubber Grommet Passe Fils en Caoutchouc Arandelas Aislantes de Caucho 150 2225 po Cut Dimension 1 25 oo Remove Stem Material Enlever le MatEriel de Tige Quite el Tallo la Materia ALIS Items Not Included with WRS 9EN Basin Kit Articles Non Inclus avec Kit de Bassin WRS 9EN Los Articulos No Incluyeron con Juego de Palangana WRS 9EN SPECIFICATIONS CARACTERISTIQUES ESPECIFICACIONES Model No N du Modele Shutoff Ft T te d arr t Pieds pie Gallons Per Min GPM Ht Gallons Min GPM Hauteur A Te Minuto oa ka Amp res Watts te e Voltios Hertzios Amperios vale NS ie he tet ere Ta CFR BI te 2 Ul egute Les ensembles pour eaux us es de Little Giant sont soigneusement emball s et inspect s et ils ont subi des essais afin
14. oper operation If neces sary remove pump from basin and remove the screws that hold the base plate and screen to motor housing Remove baseplate and screen and clean impeller TYPICAL INSTALLATION Figure 3 Cordon Prise Mi Cable El INSTALLATION TYPIQUE and volute passage Do not use strong solvent on impeller Clean using a mild detergent and water and reinstall See pump manual for other information For any other pump repair return the pump to a Little Giant authorized service center FOR TROUBLESHOOTING INFORMATION SEE PUMP OWNERS MANUAL INCLUDED WITH WRS 9EN BASIN KIT Instructions for replacement of RVMS Pump Switch C N 599261 STEP 1 CAUTION make certain that the unit is disconnected from the power source before attempting to service or rework any components STEP 2 Disconnect unit from inlet pipe vent pipe and discharge pipe STEP 3 Remove the 14 machine screws Figure 2 ltem 8 from around the basin cover STEP 4 Take off basin cover and remove cord grommet Figure 2 Item 1 STEP 5 Remove RVMS Pump Switch cord from the cord grommet STEP 6 Loosen the stainless steel clamp that attaches the RVMS Pump Switch to the discharge pipe Figure 2 ltem 4 STEP 7 Slide the RVMS Pump Switch up and off the discharge pipe Be careful to note the switch s orientation for re assembly STEP 8 Trim 1 25 from the replacement RVMS Pump Switch stem as is detailed in Figure 4 Orientate the rubber grommet appr
15. oximately 1 5 from the newly cut bottom of the switch stem STEP 9 Clean out the basin to ensure maximum product performance Replace the RVMS Pump Switch in the reverse order in which it was removed INSTALACION T PICA Power Cord Piggyback Plug d Alimentation avec xte ctrico con Enchufe Incorporado Check valve Clapet anti retour V lvula de Retenci n Discharge pipe Tuyau de refoulement Tuber a de descarga Union Raccord Uni n a ltems Not Included with WRS 9EN Basin Kit Articles Non Inclus avec Kit de Bassin WRS 9EN Los Articulos No Incluyeron con Juego de Palangana WRS 9EN Incluye un adaptador liso de 2 x 1 1 2 MNPT por si es requerido Un adaptateur a glissement de 2 x 1 1 2 MNPT est fourni 2 slip x 1 1 2 MNPT adapter provided Use if required 1 1 2 Discharge pipe 1 1 2 po Tuyau de refoulement 1 1 2 Tuberia de descarga Basin Cover Bassin Couvercle Cubeta Uni n Basin Bassin Cubeta Discharge pipe Tuyau de refoulement Tuberia de descarga 15 68 Cover O Ring Couvercle avec joints toriques Intake late Cubierta O Ring Prise Toma Pump La Pompe La Bomba A L752 2 vent pipe 2 tuyau de ventilation 2 tubo de ventilacion 1 1 2 slip x 2 MNPT adapter is provided if a 1 1 2 vent is required Au cas d un event de 1 1 2 un adaptateur a glissement de 1 1 2 x 2 MNPT est fourni I
16. pulg de la parte inferior de la base del interruptor reci n cortada PASO 9 Limpie la cubeta para asegurar el rendimiento m ximo del producto Reemplace el interruptor para la bomba RVMS en el orden inverso al que se quit ce id ee 1 800 701 7894 Pour l aide technique entrez s il vous plait en contact 1 800 701 7894 Para la ayuda t cnica por favor p ngase en contacto 1 800 701 7894 www LittleGiantPump com customerservice lgpc com Form 998718 03 2012 Rev 001 2012 Franklin Electric Co Inc Little Giant is a registered trademark of Franklin Electric Co Inc
17. rie d amen e d air avec siphon en S et union le couvercle du bassin comprend un raccord de 38 mm 1 1 2 po filetage NPT femelle 2 Tuyauterie de vidange avec clapet de non retour battant et union le couvercle du bassin comprend un raccord de 38 mm 1 1 2 po filetage NPT femelle 3 Tuyau de ventilation le couvercle du bassin comprend un raccord de 51 mm 2 po filetage NPT femelle et une union de 51 mm 2 po DIRECTIVES DE SECURITE A AVERTISSEMENTA 1 MISE EN GARDE S assurer que la pompe est d branch e avant de retirer ou de faire l entretien de toute pi ce 2 Bien lire les instructions du Guide de s curit Le non respect des consignes de s curit peut causer de graves blessures ou des dommages la propri t ou les deux 3 V rifier les codes du b timent et de l lectricit avant l installation Celle ci doit tre conforme aux r glements contenus dans ces codes Durant le fonctionnement normal du syst me la pompe puisard est immer g e donc invisible C est pourquoi il faut faire attention si on travaille pr s de celle ci a D brancher la pompe avant d y toucher ou d en faire l entretien ou la r paration b Afin de r duire le risque d lectrocution faire preuve d une grande prudence pendant le remplacement des fusibles Ne pas avoir les pieds dans l eau pendant le remplacement des fusibles et ne pas ins rer le doigt dans les culots de fusibles CONNEXIONS ELECTRIQUES AVERT
18. s o cinta adhesiva Llene la unidad de agua a trav s de la toma La bomba debe encenderse con 7 a 10 cm de agua en el tanque y debe apagarse cuando queden 2 a 5 cm en el tanque MANTENIMIENTO Las operaciones de mantenimiento consisten en limpiar la cubeta y manten imiento limitado de la bomba ADVERTENCIA Antes de realizar cualquier tipo de mantenimiento apague la entrada de agua y desconecte el cable de energ a el ctrica del suministro de energ a Durante el funcionamiento la bomba puede calentarse Deje que se enfr e antes de realizar el servicio t cnico CUBETA el sedimento se puede acumular en la cubeta haciendo que la bomba funcione de manera indebida Quite los 10 tornillos de 6 35 mm de ancho banda de rodamiento 20 1 4 20 de la tapa Quite el ojal del cable afloje los cables para que haya holgura y luego quite la tapa Saque la bomba y limpie la cubeta con un detergente suave y agua Vuelva a ensamblar la bomba en el orden inverso en que se realiz el ensamblado Torsione los tornillos entre 2 03 y 2 25 Nm 18 y 20 pulg por libra BOMBA El sedimento o pelusa puede tapar la bomba y ocasionar el funciona miento indebido Si es necesario saque la bomba de la cubeta y quite los tornillos que sujetan la placa base y la malla al alojamiento del motor Saque la placa base y la malla luego limpie el impulsor y el pasaje del espiral No utilice solventes fuertes en el impulsor Limpielos con un detergente suave y agua y vue
19. servoir loin de tout objet qui pourrait le perforer Placer la pompe pour que la position de l entr e et de la sortie des tuyaux d a ration et des fils lectriques soit convenable TAPE 2 Faire le raccordement de l entr e l aide d un tuyau filet de 1 1 2 po relier l entr e au raccord du couvercle du r servoir Utiliser un clapet en P et un raccord union proximit du r servoir Utiliser une p te joints pour tuyaux et ne serrer les raccords de plastique qu la main Eviter d utiliser des tuyaux inf rieurs 1 1 2 po de diam tre TAPE 3 Installer l vacuation bien d aplomb Utiliser un tuyau filet de 38 mm 1 1 2 po pour installer l vacuation d aplomb avec le raccord du couvercle Il est recommand d utiliser un clapet de non retour pour viter le refoulement de l eau dans le puisard Installer le clapet de non retour aussi pr s que possible de la partie sup rieure du bassin afin d viter le fonctionnement cyclique de la pompe S assurer que le clapet de non retour est install dans le sens du d bit Si le clapet de non retour est install l envers l eau ne pourra sortir de l appareil S assurer que la tuyauterie d vacuation est scell e avec un compos pour joint de tuyau et que la hauteur de lev e de la pompe n est pas d pass e Serrer les raccords en plastique la main seulement TAPE 4 Faire le raccordement du tuyau d a ration l aide d un tuyau filet de 2 po relier le tuy
20. trica antes de darle servicio o quitar algunos de sus componentes 2 Lea todo el instructivo el no seguir estas recomendaciones puede causar serios da os a la persona y al equipo 3 Consulte los c digos el ctrico y de construcci n locales antes de la insta laci n La instalaci n deber hacerse de acuerdo con sus reglamentaciones Durante el funcionamiento normal la bomba de sumidero est inmersa en agua Se debe observar precauci n para prevenir lesiones personales al trabajar cerca de la bomba a Debe sacarse el enchufe de la toma de corriente antes de tocar limpiar o reparar la bomba b Para disminuir el riesgo de choques el ctricos posiblemente fatales tenga sumo cuidado al cambiar los fusibles No pise agua mientras cambia los fusibles ni introduzca el dedo en el recept culo del fusible CONEXIONES ELECTRICAS Y A ADVERTENCIA A Todo el cableado debe cumplir con los c digos locales y se recomienda emplear un contratista el ctrico licenciado para el trabajo La bomba est equi pada con un enchufe de tres puntas Los enchufes deben estar conectados a un tomacorriente puesto a tierra y el tubo de desahogo debe permanecer sin obstrucci n para una operaci n apropiada de la bomba La bomba debe operarse en un circuito separado con un fusible o interruptor autom tico de circuito y un GFCI interruptor de circuito por falla del aterramiento Aseg rese de que el suministro el ctrico es igual al indicado en la placa
21. ure 2 article n 1 TAPE 5 D poser le cordon de l interrupteur flotteur m canique vertical de la pompe de l illet de cordon TAPE 6 Desserrer la pince en acier inoxydable qui retient l interrupteur flotteur m canique vertical de la pompe au tuyau d vacuation Figure 2 article n 4 TAPE 7 Faire glisser l interrupteur flotteur m canique vertical de la pompe vers le haut pour l extraire du tuyau d vacuation Veiller prendre note de l orientation de l interrupteur pour le r assemblage TAPE 8 Couper 32 mm 1 25 po de la tige de l interrupteur flotteur m ca nique vertical de la pompe comme il est d crit dans la Figure 4 Orienter l illet en caoutchouc environ 38 mm 1 5 po de la nouvelle extr mit coup e de la tige de l interrupteur TAPE 9 Nettoyer le bassin pour assurer un rendement maximal de l appareil Remettre en place l interrupteur flotteur m canique vertical de la pompe dans l ordre inverse de sa d pose INTRODUCCI N Los juegos para aguas residuales Little Giant se embalan inspeccionan y prueban cuidadosamente para garantizar el funcionamiento y entrega seguros Al recibir la unidad exam nela cuidadosamente para determinar que durante el env o no se haya roto o da ado ninguna pieza o que falte alguna de ellas Si se produjo alg n da o an telo y notifique a la empresa que le vendi la unidad Deber n darle asistencia para obtener la reparaci n o reempla
22. zo si se requiere Lea este manual cuidadosamente y tambi n el manual de la bomba incluido Esta unidad se dise a para bombear agua residual de las bandejas de lavander a lavadoras lavaderos o deshumidificadores La unidad no se dise a para bom 3 bear aguas cloacales sin tratar o liquidos que no sean agua La unidad puede bombear l quidos con s lidos esf ricos de hasta 19 05 mm 3 4 pulg La tem peratura maxima de los liquidos es de 52 C 125 F La unidad se disena para caber debajo de la mayoria de los lavaderos y en muchos casos no es necesario empotrarla en el piso MATERIAL QUE DEBE COMPRAR NOTA Las normas en algunas jurisdicciones estatales o locales requieren que un contratista autorizado realice todas las conexiones el ctricas y o de plomeria Es responsabilidad del cliente determinar las normas a seguir y cumplir con stas Si el usuario puede instalar la unidad debera adquirir el siguiente material 1 Tubo de entrada con trampa y junta la tapa de la cubeta tiene un accesorio con FNPT de 38 1 mm 1 1 2 pulg 2 Tuber a de descarga con v lvula de retenci n de charnela y junta la tapa de la cubeta tiene un accesorio con FNPT de 38 1 mm 1 1 2 pulg 3 Tuber a de ventilaci n la tapa de la cubeta tiene un accesorio con FNPT de 50 8 mm 2 pulg y una junta de 50 8 mm 2 pulg NORMAS DE SEGURIDAD Y ATADVERTENCIALA 1 PRECAUCION Aseg rese que la bomba est desconectada de la fuente el c