1. NOTE For specific AC control wire information please refer to the HVAC systems Owner s Operation Manual APPENDIX D DIGITAL LOAD MANAGEMENT DLM MODULES The load controller can operate up to four separate DLM s each one connected the same way as below e The NEMA 3R Enclosure of the DLM module can be installed indoors or outdoors If mounting outdoors the enclosure MUST be orientated with the drain hole the bottom The module is fitted with conduit knockout locations These knockout locations are the only locations that conduit should be attached to the enclosure A grounding stud 15 provided inside the enclosure in order to ground the conduit CONNECTING LOAD SHED MODULE LSM CONNECTIONS The LSM can control an air conditioner 24 Vac directly or a separate contactor 120 Vac which can control any load connected to it See Figure Sequence of Operation The 4 green status LEDs will indicate when a load priority level is enabled e All loads are enabled when the transfer signal is off ATS in Utility position e f the transfer signal is pulled low Active e All loads are e
2. 15 Operational TESTING sara 16 Appendix C Digital Load Managment DLM 18 Appendix D Digital Load Managment DLM Modules 19 Connecting Load Shed Module LSM Connections 19 Appendix E Setting the Automatic Exercise Function 20 PU oO 21 SEEE NE 22 GUIAS DE INSTALACION 35 CONSIGNES D INSTALLATION 59 INTRODUCTION Thank you for purchasing this compact high performance air cooled engine driven generator is designed to automatically supply electrical power to operate critical loads during a utility power failure This unit is factory installed in an all weather metal enclosure that 15 intended exclusively for outdoor installation This generator will operate using either vapor withdrawn liquid propane LP or natural gas NG NOTE This generator is suitable for supplying typical residential loads such as Induction Motors sump pumps refrigerators air conditioners furnaces etc Electronic Components computer monitor TV etc Lighting Loads and Microwaves READ THIS MANUAL THOROUGHLY If any portion of this manual is not understood contact the nearest Dealer for starting operating and servicing procedures Throughout this publication and on tags and decals affixed to the g
3. 40 ce 70 amp breaker supplied by the dealer AP NDICE E FIJANDO LA FUNCI N DE EJERGIGIO AUTOM TICO La pantalla entrar en un modo de asistente de instalaci n cuando se conecte la bater a por primera vez El asistente le pedir ingresar primero la fecha y hora actual y luego el d a y hora del ejercicio Si la bater a se desconecta y reconecta alguna vez o se reemplaza el fusible el asistente de instalaci n se mostrar otra vez pero s lo se deber ingresar la fecha y hora actual 3 Sies necesario cambiar la hora o d a del ejercicio presione la tecla de escape para acceder al men principal 4 Presione la flecha izquierda o derecha hasta que destelle Edit y presione enter 5 Presione la flecha izquierda o derecha hasta que se muestre la hora del ejercicio y presione enter 6 Usando la flecha y la tecla enter fije primero la hora del ejercicio en formato de 24 horas seguido por el minuto y finalmente el d a 7 Una vez fijada el generador se ejercitar cada semana a la misma hora Aseg rese de mostrar a los propietarios c mo fijar la funci n de ejercicio para el d a y hora en que lo requieran 8 Si el generador est equipado con la caracter stica de ejercicio de baja velocidad este fue habilitado de f brica y no se necesita ajuste alguno Cada instalaci n tiene sus propias circunstancias y requerimientos Este folleto proporciona gu as para instalaciones b sicas sola
4. Le a s J gt 1 e 2 x i 240Vac CONNECT BLACK BATTERY WARMER 0 OPTIONAL _ O NOTE ALL WIRES 18 AWG 300V UL LISTED UNLESS BATTERY SHOWN OTHERWISE AWG SIZE 0 12 23 Wiring Diagram Schematic 8kW Drawing No 0H6912 A Electrical Data GENERATOR OUTPUT 5 240 11 44 WINDING EXCITATION OPTIONAL 0742 6 WINDING _ NEUTRAL g7 A kA A y por CONNECT IPIN 1 N2A e dl OPTIONAL 0 me ER log 4 2 2 lt T 6 Most CONNECT 00 WHT N1 om N2 00 1888 A m 0 0 p 11 p v MOV NI 240 vac UTILITY ES N2 INPUT Q 120 VAC CONTROLLER PRINTED CIRCUIT BOARD LED BOARD ee 121 818 ui 85 HTO E Q 86 y COMMON 14 210 69 ALARM i 9 Oh GROUND 194 BATTERY 0 23 TRANSFER LEGEND BA BRUSH ASSEMBLY CB1 CIRCUIT BREAKER MAIN OUTPUT CS CHOKE SOLENOID FS FUEL SOLENOID 13 13 BATTERY 12 T 0 24 HTO HIGH TEMPERATURE SWITCH IGNITION MODULE LOP LOW OIL PRESSURE SWITCH MOV VARISTOR SC STARTER CONTACTOR SCR STARTER CONTROL RELAY SM STARTER MOTOR SP_ SPARK PLUG Wiring Diagram Schematic 10 14kW D
5. 36 Contenido I na 37 Operaci n y 37 C mo obtener 5 1 10 37 A 37 ndice de est ndares 39 Desempaque inspecci n 39 Sistemas de protecci n idad 3 Requerimiento de NEC para interrupci n de circuito por falla de arco interruptor para dormitorios 39 Secci n 210 12 Protecci n de interruptor circuito falla de arco 39 ABLES BE CIDE 40 Preparaci n del sitio y ubicaci n del generador 40 Conversi n a Gas licuado de petr le0 41 Instalaci n y conexi n de l neas de gas 42 Conexiones el ctricas 43 Activaci n del general sisi 43 Cartilla de activaci n eee 44 Conexiones del generador Interruptor EZ 45 Ap ndice A Instalaci n del interruptor EZ y pruebas A A 46 Instalaci n de la Dania 48 Prdebas de ODE raramente 48 Ap ndice B Interruptor de transferencia RTSX y RTSD
6. 5 les mod les 10 20 kW localiser le fermoir en m tal qui est emball dans le sac du manuel d entretien Ins rer le fermoir dans la fente situ e sur le c t gauche de la boite externe du disjoncteur 5 assurer que le clip du fermoir fait face l avant du g n rateur Si on le souhaite verrouiller la boite externe ACTIVATION DU GENERATEUR Lorsque la puissance de la batterie est appliqu e au g n rateur au cours du processus d installation le contr leur s allume Toutefois le g n rateur doit encore tre activ avant de d marrer automatiquement en cas de panne de courant l activation du g n rateur est un simple processus en un geste guid par les invites de l cran du contr leur Une fois que le produit est activ l cran du contr leur ne vous invite pas nouveau m me si vous d branchez la batterie du g n rateur Apr s avoir obtenu votre code d activation veuillez suivre les tapes suivantes sur le panneau de contr le du g n rateur dans le tableau d activation affich la page suivante 67 TABLEAU D ACTIVATION S LECTIONNER LANGUE D PANNAGE L cran indique Langue Anglais e TA TY Yers L cran indique Activer en appuyant sur Entr e ou appuyer sur Echap pour utiliser le mode manuel vio L cran indique Pour Activer allez sur www activategen com eo A V e Utilisez TOUCHES de direction pour d filer jusqu la lan
7. 1 p 7 T 44 Se Tu 1 If installing the RTSD switch the service was changed so make sure the terminations are good before re energizing the utility 2 Switch the main utility breaker OFF Refer to NFPA 70 for the safety equipment required when working inside a live transfer switch 3 Energize the utility and check line to line and line to neutral voltage at terminals N1 and N2 on the transfer contactor line to line voltage is not approximately 240 volts de energize utility power and check the terminations between the utility and N1 and If line to neutral voltage is not approximately 120 volts de energize utility power and check the neutral terminations Repeat the same voltage checks on terminals T1 and T2 to make sure current is flowing properly through the contactor 4 Switch the generator s main circuit breaker OFF and put the mode switch in the OFF position E 9 Switch the generator s main circuit breaker OFF and put the mode switch in the OFF position to shut down the generator 5 Make sure utility power is OFF and place all of the individual circuit breakers in the main distribution panel in the OFF position 10 With utility power still OFF use the transfer handle to move the LT main contacts to the UP utility position 6 Locate the transfer handle insert the metal end into the slot in the main contactor assembly Pull the handle DOWN to move the m
8. 4 1 240Vac CONNECT 251 PIN 6 54 3 2 1 MA IA S em L OPTIONAL T O 4 MB ae N2B 2 6 11 44 ac CONNECT N1 pouce N2 00 00 WHT 00 AA RE uz E 11 nt UTILITY E N2 N2 INPUT 120 i LOAD SUPPLY 0 100 2 44 T1 N2 11 9 4 1 120 VAC 00 X Accessory POWER CONTROLLER PRINTED CIRCUIT BOARD 0 OUTPUT GOVERNOR ACTUATOR FIELD BOOST DIODE LED BOARD 1 85 4 817 819 820 210 56 56 LAM 818 BAIL s e FW 819 PE 56 7 T CH 199 98 14 Es 210 ALARM ott cK GROUND 1 a 0 0 O d 194 r BATTERY 23 amp Q TRANSFER SP1 LEGEND lt H IM 18 BA BRUSH ASSEMBLY CB1 CIRCUIT BREAKER MAIN OUTPUT 15 13 13 CB2 CIRCUIT BREAKER GFCI CS CHOKE SOLENOID BATTERY FS FUEL SOLENOID 12V SCR HTO HIGH TEMPERATURE SWITCH IM_ IGNITION MODULE 0 16 SP2 LOP LOW OIL PRESSURE SWITCH lt 18 MOV VARISTOR SC SC STARTER CONTACTOR 5 SCR STARTER CONTROL RELAY SM STARTER MOTOR 33 No 0H8538 Revision E 06 23 10 Catalog IM ASPEA 01 Printed in U S A GU AS DE INSTALACI N Generadores enfriados por aire INDICE Mi O l NOU usun u 36 Lea este manual completamente
9. Fuel Selection Lever In Position for Natural Gas Fuel x gt 259 2 e fis a lt 9 3 Sur les unit s de 10 kW ouvrir le desserrer le collier avant situ sur le tuyau d admission d air et faire glisser le tuyau du raccord tuyau flexible d Fuel Selection Lever Position for Liquid Propane Vapor Fuel 4 Faire glisser la goupille du s lecteur de carburant sur le carburateur vers l arri re de l enveloppe 5 Remplacer le tuyau d admission et serrer le collier fermement Fuel Selection Lever Out Position for Liquid Propane Vapor Fuel 6 Sur tous les autres modeles retirer simplement le couvercle du filtre air et faire glisser la goupille du s lecteur de carburant vers l ext rieur de la position de gaz naturel la position de PL 65 INSTALLATION ET RACCORDEMENT DES CANALISATIONS DE GAZ e 2 X ad cM TN p gt wk EA b Lee 2 1 Le gaz naturel la vapeur de PL sont des substances fortement volatiles par cons quent le fait de se conformer strictement toutes les proc dures codes normes et r glementations de s curit est essentiel Les raccordements des canalisations de gaz doivent tre effectu s par un plombier certifi qui conna t les codes locaux Toujours utiliser un tuyau de gaz un colmatant de tuyau ou une p
10. 12 Un fil de commande mal branch peut endommager le tableau de contr le du g n rateur ANNEXE A INSTALLATION ET TEST OPERATIONNEL DU aan EZ 70 1 Avant de commencer l installation s assurer que l appareil est hors tension sur le panneau de distribution principal et lire attentivement le Manuel d entretien fourni avec le commutateur de transfert Le commutateur du centre de distribution doit tre mont assez pr s du panneau de distribution principal pour accueillir le conduit pr c bl de deux pieds S assurer que ni l eau ni des substances corrosives ne coulent sur le boitier du commutateur de transfert ae SU ERIT Ds Tow LOW M ET ES p id Toujours inspecter le commutateur pour s assurer qu il n a pas subi de dommages pendant le transport Ne jamais monter un commutateur de transfert qui montre des signes de dommage Ae EE 3 Prot ger le commutateur contre les impacts et le monter verticalement sur une structure de support rigide S assurer que le commutateur est niveau et d aplomb Le commutateur de transfert est un commutateur coupure Le commutateur a coupure emp che la r troaction divergente lectrique entre le g n rateur et le r seau public en permettant seulement aux circuits de charge d tre connect s une seule alimentation la fois 4 Chaque fil du commutateur de transfert pr c bl est cod par couleur pour
11. STARTER CONTACTOR SCR STARTER CONTROL RELAY SM STARTER MOTOR SP_ SPARK PLUG d SPLICE 1 DISCONNECT SPLICE IC BATTERY WARMER OPTIONAL NOTE ALL WIRES 18 AWG 500V UL LISTED UNLESS SHOWN OTHERWISE AWG SIZE 12 Electrical Data Wiring Diagram Schematic 10 14kW Drawing No 0H7358 A AS Te e 240 VAC PE GENERATOR 14 Z OUTPUT WINDING ROTOR 33 EXCITATION OPTIONAL 7 22 0 4 2 6 WINDING BATTERY WARMER codo O IN s 4 NEUTRAL ES 5 4 3 2 1 o PIN Don N2A ee T l OPTIONAL 0 4 N1B N2B Z ac 251 do TO _ N1 N2 00 m 0 0 11 Nt X 240 VAC T d UTILITY T un 120 VAC l LOAD SUPPLY CONTROLLER PRINTED CIRCUIT BOARD GOVERNOR ACTUATOR FIELD BOOST DIODE LED BOARD 3 85 14 817 819 820 210 357R 820 14kW 768R 817 818 MW 819 56 56 0 14 2 0 ALARM 14 LOP 14 0 GROUND 0 0 9409 BATTERY B 23 TRANSFER BREAKER MAIN OUTPUT lt H M1 18 BA BRUSH ASSEMBLY CS CHOKE SOLENOID 5 79 COMMON 13 13 13 FS FUEL SOLENOID BATTERY HIGH TEMPERATURE SWITCH SCR IM IGNITION MODULE LOP LOW OIL PRESSURE SWITCH 0 16 5 2 VARISTOR SC
12. Coloque el interruptor de modo del generador en MANUAL para arrancar el motor Deje que el motor caliente luego conmute el interruptor principal 11 Cierre el interruptor principal para encender la energ a p blica del generador a la posici n ON encendido El generador est ahora suministrando electricidad al interruptor de transferencia pero no est llevando ninguna carga U 12 Conmute el interruptor principal del generador a la posici n ON y coloque el interruptor de modo en AUTO 8 Aseg rese de que el voltaje y la frecuencia del generador sea correcta Si el voltaje de l nea a l nea no es aproximadamente 240 voltios consulte los procedimientos apropiados de ajuste en el manual del propietario Si el voltaje de l nea a neutro no es aproximadamente 120 voltios revise las conexiones de neutro entre el generador y el interruptor de transferencia 53 13 Apague la energ a p blica y aseg rese de que el generador arranca autom ticamente luego del retardo del interruptor de linea 14 Conmute el interruptor de energ a p blica a ON y aseg rese de que la energ a se transfiera autom ticamente de regreso al servicio p blico 15 Apague la energ a p blica nuevamente para arrancar autom ticamente el generador Cuando la energ a se haya transferido al generador cierre cada uno de los interruptores en el panel de distribuci n uno a la vez hasta que el generador haya ac
13. FUN F IBERIA 1722 2 If the EZ Switch was purchased separately from the generator the 5 seal tite whip will need to be connected to the generator To complete the wiring run the conduit for the power leads and control wires from the external connection box to the generator 8 Now connect the red and black power leads to the circuit 3 Remove the two screws securing the connection area cover breaker Since this is a single phase application it doesn t and remove the cover matter which wire is connected to which lug 9 Connect the green equipment ground wire to the ground bus bar and torque to 35 inch lbs The torque values are e 10 14 AWG 35 in lbs 8 AWG 40 in Ibs 4 6 AWG 45 in Ibs 4 Feed the wires through the back of the generator and secure the conduit with the lock nut 5 Run the power leads through the strain relief provided A amp AR Neutral Oe GJ S DE A J Nl RQ Li 2 Ground Cable Tie Location 10 Connect the white neutral wire to the neutral bus bar and torque to 35 inch lbs The torque values are e 10 14 AWG 35 in lbs 8 AWG 40 in Ibs e 4 6 AWG 45 in Ibs Connect the control wires to the correct terminals The terminals are clearly marked N1 N2 23 194 and T1 If connecting a pre wired switch a 0 zero wire will also be required NOTE In order to
14. S assurer que la tension et la fr quence du g n rateur sont correctes Si la tension phase phase n est pas d environ 240 volts se reporter au Manuel d entretien pour consulter les proc dures de r glage appropri es Sur tous les mod les si la tension phase phase n est pas de 120 volts v rifier le branchement du fil neutre entre le g n rateur et le commutateur de transfert 6 Une fois la v rification de la tension termin e placer le disjoncteur principal du g n rateur et le s lecteur de mode sur la position OFF Arr t pour teindre le g n rateur 7 S assurer que le disjoncteur bipolaire install sur le panneau de distribution principale est plac sur la position OFF Arr t 8 Utiliser la poign e de transfert pour d placer les contacts principaux du commutateur de transfert vers la position UP r seau public Placer le disjoncteur bipolaire du panneau de distribution sur la position ON Marche 9 Apr sent placer le disjoncteur principal du g n rateur sur la position ON Marche et le s lecteur de mode sur la position AUTO IPE E 10 Mettre le r seau public hors tension et s assurer que le g n rateur d marre automatiquement 11 Si tout fonctionne correctement placer le disjoncteur principal sur la position ON Marche et s assurer que l alimentation est automatiquement transf r e vers le r seau public 12 Une fois que le moteur a r alis son cycle d
15. e FRIDGE MODULE 3 L d e Er E2 drm T2 ANNEXE E DEFINITION DE LA FONCTION DE PROGRAMME DE TEST AUTOMATIQUE L cran passera en mode d assistant d installation lorsque l alimentation de la batterie est branch e en premier L assistant demandera d abord d entrer la date et l heure actuelles suivi du jour et de l heure de programme de test Si la batterie a d j t d branch e et rebranch e ou si le fusible a t retir et remplac l assistant d installation s affichera nouveau mais il faudra uniquement entrer la date et l heure actuelles 3 Sil faut modifier l heure ou le jour de programme de test appuyer sur la touche chap pour acc der au menu principal 4 Appuyer sur la touche de direction gauche ou droite jusqu ce que Edit Modifier clignote et appuyer sur Entr e 5 Appuyer sur la touche de direction gauche ou droite jusqu ce que la dur e du programme de test s affiche et appuyer sur Entr e 6 l aide des touches de direction et Entr e d finir l heure du programme de test en format de 24 heures suivie des minutes et enfin du jour 7 Une fois d fini le g n rateur effectuera le programme de test chaque semaine au m me moment S assurer de montrer aux propri taires comment d finir la fonction de programme de test pour le jour et l heure auxquels ils souhaitent que l u
16. etc cargas de iluminaci n y microondas LEA ESTE MANUAL COMPLETAMENTE Si alguna parte de este manual no se entiende bien p ngase en contacto con el concesionario m s cercano para conocer los procedimientos de arranque operaci n y servicio A lo largo de esta publicaci n y en lo que respecta a las etiquetas y calcoman as fijadas en el generador los bloques de PELIGRO ADVERTENCIA CUIDADO Y NOTA se usan para alertar al personal sobre instrucciones especiales sobre una operaci n en particular que puede ser peligrosa si se ejecuta en forma incorrecta o sin cuidado Obs rvelas con cuidado Sus definiciones son como sigue A PELIGRO INDICA UNA SITUACI N PELIGROSA O ACCI N QUE SI NO SE EVITA TRAER COMO RESULTADO LA MUERTE O UN DA O SERIO AADVERTENCIA Indica una situaci n peligrosa o acci n que si no se evita podr a traer como resultado la muerte o un da o serio ACUIDADO Indica una situaci n peligrosa o acci n que si no se evita puede traer como resultado un da o menor o mo derado NOTA Las notas contienen informaci n adicional importante para un procedimiento y se les encontrar dentro del cuerpo de este manual Estas advertencias de seguridad no pueden eliminar los peligros que indican El sentido com n y un estricto cumplimiento de las instrucciones especiales cuando se realiza la acci n o servicio son esenciales para evitar accidentes Cuatro s mbolos de seguridad usados com nm
17. luego el cable NEGATIVO al final Nunca use el generador ni alguna de sus partes como escal n Pararse sobre la unidad puede tensar y romper partes y puede traer como resultado condiciones peligrosas de operaci n como escape de gases combustible o aceite PELIGROS EL CTRICOS Todos los generadores cubiertos por este manual producen voltajes el ctricos peligrosos y pueden causar descargas el ctricas fatales El servicio el ctrico dom stico entrega voltajes altos y peligrosos al interruptor de transferencia como lo hace el generador cuando est en operaci n Evite el contacto con cables pelados terminales conexiones etc mientras la unidad est funcionando Aseg rese que todas las cubiertas protecciones y barreras apropiadas se encuentren en su lugar y o bloqueadas antes de operar el generador Si es necesario trabajar alrededor de una unidad en operaci n p rese sobre una superficie seca y aislada para reducir el peligro de choque el ctrico No manipule ningun tipo de dispositivo el ctrico mientras est de pie sobre agua con los pies descalzos o con las manos o pies h medos PUEDE HABER UNA DESCARGA ELECTRICA COMO RESULTADO El C digo El ctrico Nacional NEC requiere que el marco y las partes externas que son conductores el ctricos est n conectadas a una conexi n a tierra aprobada Los c digos el ctricos locales pueden asimismo requerir una apropiada conexi n a tierra del sistema el ctrico del generador Lu
18. n 70 NFPA HANDBOOK OF NATIONAL ELECTRIC CODE Manuel NFPA du code lectrique national disponible comme pr c demment 6 Article X NATIONAL BUILDING CODE Code de construction national disponible aupr s de l American Insurance Association 85 John Street New York N Y 10038 7 AGRICULTURAL WIRING HANDBOOK Manuel de cablage agricole disponible aupr s du Food and Energy Council 909 University Avenue Columbia MO 65201 8 ASAE EP 3634 INSTALLATION AND MAINTENANCE OF FARM STANDBY ELECTRICAL SYSTEMS Installation et maintenance des systemes lectriques de secours pour les fermes disponible aupr s de l American Society of Agricultural Engineers 2950 Niles Road St Joseph MI 49085 9 NFPA n 30 FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE Code relatif aux liquides inflammables et combustibles disponible comme pr c demment A DANGER Seuls des lectriciens ou des prestataires qualifi s doivent travailler sur ces installations qui doivent tre strictement conformes aux codes normes et r glementations applicables DEBALLAGE INSPECTION Apr s le d ballage inspecter attentivement le contenu afin de s assurer qu il n y a pas de dommage Ce g n rateur de secours est pr t tre install avec une plaque de pose fournie et pr mont e en usine et est quip d une enveloppe imperm able destin e une installation l ext rieur uniquement Ce g n rateur de secours certifi UL peut tr
19. requiere que se instale un interruptor de transfer encia El interruptor de transferencia debe aislar efectivamente el sistema el ctrico del sistema de distribuci n de energ a p blica cuando el generador est operando NEC 700 701 amp 702 El no aislar un sistema el ctrico de esa manera traer como resul tado da os al generador y tambi n puede causar da os o la muerte a los trabajadores del servicio p blico el ctrico debido a una realimentaci n de la energ a el ctrica Si se nota alguna p rdida o da os el momento de la entrega haga que la persona que entrega la carga tome nota de todos los da os en la gu a de embarque o coloque su firma debajo del memo del consignatario sobre p rdida o da os Si se nota una p rdida o da o luego de la entrega separe los materiales da ados y p ngase en contacto con el transportista para los procedimientos de reclamo Da o oculto se entiende como el da o al contenido de un paquete que no se evidencia al momento de la entrega pero se descubre luego Para abrir apropiadamente el techo presione sobre el labio superior central y libere el pestillo Si la presi n no se aplica desde arriba el techo puede parecer atascado Siempre verifique que el cierre lateral est abierto antes de intentar levantar el techo REQUERIMIENTO DE NEC PARA INTERRUP TOR DE CIRCUITO POR FALLA DE ARCO PARA DORMITORIOS En 2001 el C digo El ctrico Nacional MEC present un requerimien
20. GESTION NUMERIQUE DE LA CHARGE DLM Pour contr ler un climatiseur connecter la borne Y du thermostat l une des bornes A C 1 Connecter l autre borne A C 1 la borne Y du climatiseur Utiliser un fil en cuivre de 18 26 AWG Se reporter au Manuel d entretien pour conna tre les exigences de couple connexion 2 Pour contr ler un deuxi me climatiseur r p tez les op rations ci dessus en utilisant les bornes marqu es A C 2 REMARQUE Pour des informations sur les fils de commande CA se reporter au Manuel d entretien d utilisation des syst mes de chauffage de ventilation et de climatisation ANNEXE D MODULES DE GESTION NUMERIQUE DE LA CHARGE DLM Le contr leur de charge peut exercer jusqu a quatre s par es chacune tant connect e de la mani re indiqu e ci dessous Lenveloppe NEMA du mo
21. Mettre le s lecteur de mode du g n rateur sur la position MANUAL Manuel pour d marrer le moteur Laisser chauffer le moteur puis A placer le disjoncteur principal du g n rateur sur la position ON UN Marche Le g n rateur alimente maintenant le commutateur de 11 Fermer le disjoncteur principal pour mettre sous tension l alimentation du r seau public transfert mais ne porte pas de charge www 12 Placer le disjoncteur principal du g n rateur sur la position ON 8 S assurer que la tension et la fr quence du g n rateur sont Marche et le s lecteur de mode sur la position AUTO correctes Si la tension phase phase n est pas d environ 240 volts se reporter au Manuel d entretien du g n rateur pour consulter les proc dures de r glage appropri es Si la tension phase phase n est pas d environ 120 volts v rifier le branchement du fil neutre entre le g n rateur et le commutateur de transfert 13 Mettre le r seau public hors tension et s assurer que le g n rateur d marre automatiquement apr s le d lai d interruption de ligne 14 Placer le disjoncteur du r seau public sur la position ON Marche et s assurer que l alimentation est automatiquement transf r e vers le r seau public 15 Remettre l alimentation du r seau public hors tension pour d marrer automatiquement le g n rateur Lorsque l alimentation s est transf r e vers le g n rateur fermer chaque disjoncteur du pannea
22. Supply ___ Contactor 2 Load 2 Contactor 3 Load 3 Supply Contactor 4 Load 4 Control of a Separate Contactor A separate contactor relay module can be purchased from the manufacturer If a different relay is used it must have a 120 Vac coil voltage The LSM supplies fused 5A 120 Vac to energize the coils of the relay contactors contactor 1 2 3 or 4 1 Mount the contactor module and connect the load to the main contacts 2 Connect the contactor coil to the desired LSM contactor 1 2 3 or 4 terminals on the terminal strip 3 Connect additional load shedding contactors in a similar fashion NOTE It will be necessary to determine the order of shed ding the connected loads and connect the loads to the LSM in that order One is the highest priority and four is the lowest priority A CAUTION Perform functional tests in the exact order pre sented in this manual or damage to the switch could be done IMPORTANT Before proceeding with functional tests read and make sure you understand all instructions and information in this Section Also read the information and instructions of labels and decals affixed to the switch Note any options or accessories that might be installed and review their operation NOTE This test can be performed with the utility or genera tor connected to the loads However if the generator is supplying the loads and is overloaded the control ler may have already turn
23. acondicionado 1 Enrute el cable del termostato des de la chimenea termostato a la unidad de aire acondicionado exterior al interruptor de transferencia 2 Conecte el cable a los terminales de la tira terminal Air 1 en el LSM como se muestra en la Figura 2 2 Estos son contactos normalmente cerrados que se abren en condiciones de corte de alimentaci n Enrute el cable del termostato lejos de los cables de alto voltaje 3 Si se requiere conecte el segundo aire acondicionado a los terminales de la tira terminal Air 2 Nominales del contacto Air 1 y 2 24 VAC 5 0 Amps Max Conexiones del m dulo de cambio de carga fan 0 Tierra 25 194 12v y 5 5 D D D CONTACTOR CONTACTOR Contactor 1 Carga 1 CONTACTOR B C EB Contactor 2 Carga 2 E Cables de bobina Fuente Contactor 3 Carga 3 Contactor 4 Carga 4 CONTACTOR C 95 NOTA Estas instrucciones son para una instalaci n t pica de aire acondicionado El control de la bomba de calor y los aires acondicionados de 2 etapas requer ir conexiones especiales Control de un conector separado Un m dulo de rel contactor separado se puede adquirir del fabricante Si se usa un rel diferente debe tener un voltaje de bobina de 120 El LSM suministra 120 VAC con fusibles de 5A para energizar las bobinas de los contactores del rel contactor 1 2 3 o 4 1 Monte el m dulo contactor
24. and removing the battery if installed 6 On all other models simply remove the air cleaner cover and slide the fuel selector pin outward from the natural gas to the LP position 1 3 INSTALLING amp CONNECTING GAS LINES Both natural gas and LP Vapor are highly volatile substances so strict adherence to all safety procedures codes standards and regulations is essential Gas line connections should be made by a certified plumber familiar with local codes Always use AGA approved gas pipe and a quality pipe sealant or joint compound Verify the capacity of the natural gas meter or the LP tank in regards to providing sufficient fuel for both the generator and other operating appliances F aem eT 2 Most applications will require an external manual shutoff valve on the fuel line Where the gas line is to enter the generator install a T fitting to allow for gas pressure monitoring On one opening of the fitting install a 1 4 NPT nipple and threaded plug In some cases a sediment trap may also be installed When connecting the gas line to the generator use the provided section of UL Listed or AGA approved flexible fuel line in accordance with local regulations The purpose of the flexible fuel line is to ensure that vibration from the generator does not cause a gas leak at one of the connection points so it s important that the line be installed with as few bends as poss
25. breaker box Be sure that the clip of the hasp is facing toward the front of the generator If desired lock the external box GENERATOR ACTIVATION When battery power 15 applied to the generator during the installation process the controller will light up However the generator still needs to be activated before it will automatically run in the event of a power outage Activating the generator 15 a simple one time process that 15 guided by the controller screen prompts Once the product is activated the controller screen will not prompt you again even if you disconnect the generator battery After obtaining your activation code please complete the following steps the generator s control panel in the Activation Chart shown on the following page ACTIVATION CHART CHOOSE LANGUAGE TROUBLESHOOTING Display Reads Use ARROW keys to scroll to desired If the wrong language is chosen it can be language Press ENTER to select changed later using the edit menu Language English EJ Display Reads Press ENTER to begin the activation process If ESCAPE 15 pressed instead of ENTER your generator will only run in manual mode for Activate me ENT or test purposes and NOT ACTIVATED will be ESC to run in manual displayed You will need to reconnect the battery and begin with Step 1 EN Display Reads If you do not have your activation code go to www activategen com or call To Activate go to 1 888 9ACTIVATE 922 848
26. contra impactos y monte el interruptor verticalmente manual para lograr esto Deslice la manga sobre a una estructura de soporte r gida Aseg rese de que el los cables de AC o los cables DC pero no ambos interruptor est nivelado y a plomo desde el rea de descanso del cable al exterior n del generador Use las ubicaciones de amarre de El Interruptor de transferencia es un interruptor de transici abierta Los interruptores de transici n abierta evitan la cable para sostener la manguera en su lugar qa realimentaci n el ctrica entre el generador y el servicio 12 Un cable de control conectado en forma inapropiada puede p blico permitiendo s lo que los circuitos de carga se da ao el tablero de control del generador conecten a una fuente de energ a a la vez APENDICE A INSTALACION DEL INTERRUP TOR EZ Y PRUEBAS DE OPERACION 4 Cada cable en el interruptor de transferencia pre cableado est codificado en color para emparejarse f cilmente en el panel principal con sus nuevos interruptores en el interruptor de transferencia 46 MUEVA ambos circuitos no mueva ninguno 5 Cuando se usa cable de tres dos circuitos de 9 Aseg rese de que cada circuito movido est protegido 120 voltios frecuentemente compartir n el mismo cable por el interruptor del mismo tama o en el interruptor de neutral Para evitar sobrecargar el neutral mueva AMBOS transferencia Circuitos de 1
27. d entra ner des cancers des malformations cong nitales ou pouvant tre nocifs pour le syst me reproductif AVERTISSEMENT PROPOSITION 65 CALIFORNIE Ce produit contient ou met des produits chimiques susceptibles selon l tat de Californie d entra ner des cancers des malformations cong nitales ou autres maladies pouvant tre nocives pour le syst me reproductif DANGERS GENERAUX e Pour des raisons de s curit le fabricant recommande que cet quipement soit install entretenu et r par par un d positaire d entretien ou autre lectricien ou technicien d installation comp tent et qualifi qui conna t tous les codes normes et r glementations applicables L op rateur doit respecter tous ces codes normes et r glementations applicables Les fum es d chappement du moteur contiennent du monoxyde de carbone qui peut s av rer MORTEL gaz dangereux s il est respir en concentrations suffisantes peut entra ner une perte de conscience ou m me la mort Ne pas modifier ou ajouter le syst me d chappement ou effectuer toute op ration qui rendrait le syst me dangereux ou non conforme aux codes et normes applicables Installer un d tecteur d oxyde de carbone alimentation par batterie l int rieur conform ment aux instructions et aux recommandations du fabricant Un d bit appropri non obstru d air de refroidissement et de ventilation est important pour corriger le fonctionnement du g n rateur Ne
28. de instalaci n el controlador se iluminar Sin embargo el generador a n necesita activarse antes de que funcione autom ticamente en el caso de un apag n el ctrico La activaci n del generador es un proceso simple de un solo paso que es guiado por los requerimientos de la pantalla del controlador Una vez que el producto est activado la pantalla del controlador no lo pedir nuevamente a n si se desconecta la bater a del generador 2 Retire la tapa rebatible detr s de la caja de conexiones alimente los cables a trav s de la parte de atr s de la caja y asegure al conducto con la tuerca de cierre Selle el agujero con masilla de silicona olvide enmasillar el agujero dentro de la caja tambi n Luego de obtener su c digo de activaci n por favor complete los siguientes pasos en el panel de control del generador en la cartilla de activaci n mostrada en la siguiente p gina 43 CARTILLA DE ACTIVACI N ELEGIR IDIOMA DETECCI N DE FALLAS La pantalla dice Use las teclas de FLECHA para llegar al Si se elige el idioma incorrecto se le puede idioma deseado Presione ENTER para cambiar posteriormente usando el men de Idioma seleccionar edici n Espa ol EJ La pantalla dice Presione ENTER para empezar el proceso de Si se presiona ESCAPE en lugar de ENTER activaci n su generador s lo funcionar en modo Activar me INT o manual para prop sitos de prueba y ESC p func en manu
29. des charges r sidentiels habituelles telles que les moteurs induction pompes de vidange r frig rateurs climatiseurs fours etc les composants lectriques ordinateur cran t l vision TV etc les charges d clairage et les micro ondes LIRE ATTENTIVEMENT CE MANUEL En cas d incompr hension d une partie de ce manuel contacter le d positaire le plus proche pour connaitre les proc dures de d marrage de fonctionnement et d entretien Dans tout ce manuel et sur les tiquettes et sur les autocollants appos s sur le g n rateur les blocs DANGER AVERTISSEMENT ATTENTION et REMARQUE servent alerter le personnel d instructions sp ciales au sujet d une op ration sp cifique qui peut s av rer dangereuse si elle n est pas effectu e correctement ou avec pr caution Les respecter attentivement Leurs d finitions sont les suivantes A DANGER INDIQUE UNE SITUATION OU UNE ACTION DANGEREUSE QUI 5 ELLE N EST PAS EVITEE ENTRAINERA LA MORT OU DES BLESSURES GRAVES A AVERTISSEMENT Indique une situation ou une action dangereuse qui si elle n est pas vit e pourrait entrainer la mort ou des blessures graves A ATTENTION Indique une situation ou une action dangereuse qui si elle n est pas vit e entrainera des blessures l geres ou mod r es REMARQUE Les remarques contiennent des informations suppl mentaires importantes relatives une proc dure et se trouvent dans le corps de texte r
30. design changes can occur over time so always refer to the schematics in the transfer switch Owner s Manual for the required connections and safety precautions Open Transition Switch Prevents Electrical Feedback Load Circuits Isolated to Single Power Supply 6 The transfer switch being used 15 an open transition switch Open transition switches prevent electrical feedback between the generator and the utility by only allowing load circuits to be connected to one power supply at a time SELECTED CIRCUIT COVERAGE 2 service rated transfer switch is installed between the service and the main distribution panel The service rated switch becomes the main service so no service disconnect 15 needed The existing main distribution panel becomes a sub panel 1 The generator powers only designated circuits that are grouped together and wired into a separate priority distribution panel The transfer switch 15 installed between the main distribution panel and the priority panel The amperage rating of the transfer switch must be equal to or greater than the highest amperage rating of the utility and generator breakers feeding the switch WHOLE HOUSE CIRCUIT COVERAGE 3 The grounding that 15 normally in the main panel must be accomplished in the service rated switch and must be disconnected in the existing distribution panel Refer to the National Electrical Code NEC for complete informat
31. gulier de ce manuel Ces avertissements de s curit ne peuvent pas liminer les dangers qu ils signalent Le sens commun et le respect strict des instructions sp ciales lors de l action ou l entretien sont essentiels pour viter les accidents Quatre symboles de s curit couramment utilis s accompagnent les blocs DANGER AVERTISSEMENT et ATTENTION Chacun indique le type d informations suivant Ce symbole indique des informations importantes relatives la s curit qui si elles ne sont pas suivies pourraient mettre en danger la s curit personnelle et ou les biens des autres symbole indique un risque potentiel d explosion symbole indique un risque potentiel d incendie Q Ce symbole indique un risque potentiel d lectrocution L op rateur est responsable de l utilisation correcte et sure de l quipement Le fabricant recommande fortement que l op rateur lise ce Manuel d entretien et comprenne parfaitement toutes les instructions avant d utiliser cet quipement Le fabricant recommande aussi fortement d apprendre d autres utilisateurs comment correctement d marrer et faire fonctionner l unit Cela les pr pare au cas ou ils auraient besoin de faire fonctionner l quipement pour une urgence CONTENU Ce manuel contient des informations pertinentes du propri taire pour ces mod les e Moteur GH 410 un cylindre 7 kW de GN 8 kW de PL e Moteur GT 530 deux cylindres 9 kW de GN 10 kW
32. il si Wrong Passcode Try Again gt code d acc s erron essayez nouveau s affiche Ressaisir votre code d activation Si une seconde tentative choue v rifiez le de code fourni sur activategen com S il est correct et que le g n rateur le rejette contactez 1 888 9ACTIVATE 922 8482 BRANCHEMENTS DU GENERATEUR 1 Sile g n rateur est quip d une bo te de jonction externe et d une lani re tanche de 5 pieds pr c bl e et connect e au g n rateur aucun branchement suppl mentaire n est n cessaire sur le g n rateur Sauter la section suivante et passer l Annexe A Installation et test op rationnel du commutateur EZ 2 Sile commutateur EZ a t achet s par ment du g n rateur la lani re tanche de 5 pieds devra tre connect e au g n rateur Afin d effectuer le c blage raccorder le conduit de 0 75 pouces des fils d alimentation et des fils de commande de la bo te de jonction externe au g n rateur 3 Retirer les deux vis fixant le couvercle de la zone de branchement et retirer le couvercle 4 Alimenter les fils travers l arri re du g n rateur et fixer le conduit l aide du contre crou 5 Raccorder les fils d alimentation travers le protecteur de cordon fourni 7 Retirer les fiches en plastique l int rieur de la zone d acc s du disjoncteur principal pour permettre le branchement des fils d alimentation au disjoncteur ue
33. le syst me d alimentation en carburant conform ment aux codes en mati re de carburant et de gaz Avant de mettre en service le systeme lectrique de secours usage domestique il faut purger les tuyaux du syst me de carburant et tester les fuites conform ment au code applicable Apres l installation inspecter le syst me de carburant r gulierement afin de s assurer qu il n y a pas de fuite Aucune fuite n est autoris e INDEX DES NORMES En l absence de normes codes r glementations et lois applicables les informations publi es indiqu es ci dessous peuvent servir de guide d installation de cet quipement 1 NFPA n 37 STATIONARY COMBUSTION ENGINES AND GAS TURBINES Moteurs combustion et turbines gaz stationnaires disponible aupr s de la National Fire Protection Association Association nationale pour la protection contre les incendies 470 Atlantic Avenue Boston MA 02210 2 n 76 ESSENTIAL ELECTRICAL SYSTEMS FOR HEALTH CARE FACILITIES Syst mes lectriques principaux destin s aux tablissements de soins de sant disponible comme pr c demment 3 NFPA n 54 NATIONAL FUEL GAS CODE Code national sur le gaz combustible disponible comme pr c demment 4 n 58 AMERICAN NATIONAL STANDARD FOR STORAGE AND HANDLING OF LIQUEFIED PETROLEUM GAS Norme am ricaine en mati re de stockage et de manipulation des gaz de p trole liqu fi s disponible comme pr c demment 5
34. mover los contactos principales a la posici n de energ a de respaldo o generador NUNCA OPERE EL INTERRUPTOR DE TRANSFERENCIA MANUALMENTE CUANDO LAS CARGAS EST N CONECTADAS 4 Coloque el interruptor de modo del generador en MANUAL para arrancar el motor Deje que el motor caliente luego conmute el interruptor principal del generador a la posici n ON encendido El generador est ahora suministrando electricidad al interruptor de transferencia pero no est llevando ninguna carga 5 Aseg rese de que el voltaje y la frecuencia del generador sea correcta Si el voltaje de l nea a l nea no es aproximadamente 240 voltios consulte los procedimientos apropiados de ajuste en el manual del propietario En todos los modelos si el voltaje de l nea a neutro no es 120 voltios revise las conexiones de neutro entre el generador y el interruptor de transferencia 4 6 Alterminar de revisar el voltaje conmute el interruptor de circuito principal del generador a OFF y coloque el interruptor de modo en la posici n OFF para apagar el generador 7 Aseg rese de que el interruptor de circuito de 2 polos instalado en el panel de distribuci n principal est en la posici n OFF 8 Use el manubrio de transferencia para mover los contactos principales en el interruptor de transferencia a la posici n ARRIBA servicio p blico Conmute el interruptor de 2 polos a ON en el panel de distribuci n 9 Ahora conmute el interruptor
35. pas en particulier assurez vous qu elle est sans danger pour les autres 5 assurer que la proc dure la m thode de travail ou la technique fonctionnement choisie ne rende pas le g n rateur dangereux A DANGER Malgr la conception s re de ce g n rateur faire fonctionner ce g n rateur de facon imprudente n gliger sa maintenance ou ne pas prendre de pr caution peut entrainer des blessures corporelles ou la mort Seulement autoriser les personnes responsables et comp tentes pour installer faire fonctionner et effectuer la maintenance de cet quipement Ces machines g n rent des tensions potentiellement mortelles S assurer que toutes les tapes sont suivies pour rendre la machine s re avant de commencer travailler sur le g n rateur Les pi ces du g n rateur tournent et ou sont chau des pendant le fonctionnement Soyez prudent si vous tes proximit des g n rateurs en fonctionne ment L installation doit toujours respecter les codes normes lois et r glementations applicables Un g n rateur en marche met du monoxyde de carbone et du gaz toxique inodore et invisible Respirer du monoxyde de carbone peut causer des c phal es de la fatigue des vertiges des vomissements une confusion une attaque des naus es des vanouissements ou la mort AVERTISSEMENT PROPOSITION 65 CALIFORNIE L chappement du moteur et certains de ses constituants sont susceptibles selon l tat de Californie
36. pas modifier l installation ou ne pas laisser m me un blocage partiel de l alimentation de ventilation tant donn que cela peut s rieusement affecter le fonctionnement s r du g n rateur Le g n rateur tre install et fonctionner a l ext rieur uniquement Tenir les mains les pieds les v tements etc distance des courroies de transmission des ventilateurs et d autres pi ces mobiles ou chaudes Ne jamais retirer toute courroie de transmission ou tout prot ge ventilateur pendant que l unit fonctionne Lors du travail sur cet quipement conserver l alerte tout moment Ne jamais travailler sur l quipement en cas de fatigue physique ou mentale Inspecter r guli rement le g n rateur et contacter le d positaire le plus proche pour les pi ces qui n cessitent une r paration ou un remplacement Avant d effectuer toute maintenance sur le g n rateur d brancher ses c bles de batterie afin d emp cher un d marrage accidentel D brancher le c ble de la borne de la batterie signal e par l inscription NEGATIVE N gatif NEG ou en premier puis retirer le c ble de la borne POSITIVE Positif POS ou Lors du rebranchement des c bles branchez le c ble POSITIVE Positif en premier et le c ble NEGATIVE N gatif en dernier Ne jamais utiliser le g n rateur ou n importe laquelle de ses pi ces comme marche Monter sur l unit peut craser et casser les pi ces et peut entrainer des conditi
37. point a drop in gas pressure indicates that the supply is barely adequate to supply the generator s needs Changes in the generator load or additional gas demand by other appliances may affect the generator s performance Verify gas pressure and pipe sizing Unhook the manometer and reinstall the port plug 18 The generator will continue to run to allow the engine to cool down then shut itself off 19 Shut OFF utility power again The generator should start and the entire priority load should transfer to the generator HA tlt 20 Close the main breaker to restore utility power and allow the engine to cool down and shut itself off Operational tests are now complete Refer to Appendix E Setting the Automatic Exercise Function to complete the installation APPENDIX C DIGITAL LOAD MANAGEMENT DLM 1 To control an Air Conditioner connect the Y terminal of the thermostat to one of the A C 1 terminals Connect the other A C 1 terminal to the Y terminal on the air conditioner Use 18 26 AWG copper wire Refer to the Owner s Manual for specific torque connection requirements 2 To control a second air conditioner repeat the above using terminals marked A C 2
38. positaire au sujet des pi ces et de l entretien il faut toujours fournir les num ros de modele et de s rie complets de l unit qui sont indiqu s sur son tiquette d identification qui est situ e sur le g n rateur Voir la section Le g n rateur pour connaitre l emplacement de l tiquette N de modele N de s rie REGLES DE SECURITE Conserver ces consignes Le fabricant recom mande que ces regles relatives au fonctionnement s r soient copi es et affich es proximit du site d installation de l unit Tous les op rateurs et teurs potentiels de cet quipement doivent prendre conscience de la question de la s curit Lire attentivement ces R GLES DE S CURIT avant l installation le fonctionnement ou l entretien de cet quipement Se familiariser avec ce Manuel d entretien et l unit Le g n rateur peut fonctionner en toute s curit de facon efficace et de facon fiable uniquement s il est correctement install utilis et entretenu De nombreux accidents sont dus au non respect de r gles ou pr cautions simples et essentielles Le fabricant ne peut pas anticiper toutes les situations possibles qui peuvent impliquer un danger Les avertissements de ce manuel et figurant sur les tiquettes et les autocollants appos s sur l unit ne sont toutefois pas exhaustifs Si vous suivez une proc dure une m thode de travail ou une technique de fonctionnement que le fabricant ne recommande
39. principal del generador a ON y ponga el interruptor de modo en AUTO 10 Apague la energ a p blica y aseg rese que el generador arranque autom ticamente 11 Si todo trabaja en forma apropiada conmute el interruptor principal a ON y aseg rese que la energ a se transfiera autom ticamente de regreso al servicio p blico 12 Luego de que el motor ha completado su ciclo de enfriamiento y se ha apagado apague la energ a p blica nuevamente Cuando el generador est suministrando energ a al interruptor de transferencia mueva los interruptores en el interruptor a la posici n ON uno a la vez hasta que el generador haya aceptado la carga de prioridad entera 13 Con el generador llevando la carga de prioridad entera revise la presi n del gas para verificar que est al mismo nivel que estaba antes de que arranque el generador NOTA A n si el generador est funcionando sin problemas en este punto una ca da en la presi n del gas indica que el suministro es apenas adecuado para suministrar las necesidades del generador Cambios en la carga del generador o una demanda adicional de gas por otros aparatos pueden afectar el rendimiento del generador Verifique la presi n del gas y el tama o de la tuber a Desenganche el man metro y reinstale la tapa del puerto 49 14 Encienda el interruptor principal para restaurar la energ a p blica El generador continuar funcionando para permitir que el moto
40. standards and regulations The operator also must comply with all such codes standards and regulations The engine exhaust fumes contain carbon monoxide which can be DEADLY This dangerous gas if breathed in sufficient concentrations can cause unconsciousness or even death Do NOT alter or add to the exhaust system or do anything that might render the system unsafe or in noncompliance with applicable codes and standards Install a battery operated carbon monoxide alarm indoors according to manufacturer s instructions recommendations Adequate unobstructed flow of cooling and ventilating air 15 critical to correct generator operation Do not alter the installation or permit even partial blockage of ventilation provisions as this can seriously affect safe operation of the generator The generator MUST be installed and operated outdoors only Keep hands feet clothing etc away from drive belts fans and other moving or hot parts Never remove any drive belt or fan guard while the unit is operating When working on this equipment remain alert at all times Never work on the equipment when physically or mentally fatigued Inspect the generator regularly and contact the nearest Dealer for parts needing repair or replacement Before performing any maintenance on the generator disconnect its battery cables to prevent accidental start up Disconnect the cable from the battery post indicated by a NEGATIVE NEG or first then remove
41. te joint de qualit approuv AGA V rifier la capacit du compteur gaz naturel ou le r servoir de PL afin de s assurer qu il fournit assez de carburant pour le g n rateur et d autres appareils en fonctionnement 4 w T ee Em Let ow o cx a Dam E Ma pal i m Ea w aet a h es am 2 La plupart des applications n cessiteront une soupape d arr t manuelle externe sur le tuyau de carburant 3 Afin d entrer la canalisation de gaz dans le g n rateur installer un raccord en T afin de pouvoir surveiller la pression de gaz Sur l une des ouvertures du raccord installer un mamelon NPT de 0 25 po et un bouchon filet Dans certains cas il est galement possible d installer un bassin de d cantation 66 4 Lors du raccordement de la canalisation de gaz au g n rateur utiliser la partie fournie du tuyau flexible de carburant certifi UL ou approuv AGA conform ment aux r glementations locales Le tuyau flexible de carburant sert s assurer que les vibrations provenant du g n rateur ne causent pas de fuite de gaz au niveau de l un des points de raccordement il est donc important que le tuyau soit install avec peu de coudes si possible en coude Le fait de plier le tuyau flexible r duit sa capacit absorber les vibrations contrarie son object
42. the POSITIVE POS or cable When reconnecting the cables connect the POSITIVE cable first the NEGATIVE cable last Never use the generator or any of its parts as a step Stepping on the unit can stress and break parts and may result in dangerous operating conditions from leaking exhaust gases fuel leakage oil leakage etc ELECTRICAL HAZARDS All generators covered by this manual produce dangerous electrical voltages and can cause fatal electrical shock Utility power delivers extremely high and dangerous voltages to the transfer switch as does the standby generator when it is in operation Avoid contact with bare wires terminals connections etc while the unit is running Ensure all appropriate covers guards and barriers are in place secured and or locked before operating the generator work must be done around an operating unit stand on an insulated dry surface to reduce shock hazard Do not handle any kind of electrical device while standing in water while barefoot or while hands or feet are wet DANGEROUS ELECTRICAL SHOCK MAY RESULT The National Electrical Code NEC requires the frame and external electrically conductive parts of the generator to be connected to an approved earth ground Local electrical codes also may require proper grounding of the generator electrical system After installing this home standby electrical system the generator may crank and start at any time without warning When this occurs loa
43. une correspondance facile entre les circuits du panneau principal et les disjoncteurs correspondants du commutateur de transfert or pees so Don t Move jw 9 Lorsqu un c blage trois conducteurs est utilis deux circuits de 120 volts partageront souvent le m me fil neutre Pour viter une surcharge du fil neutre d placer soit LES DEUX circuits qui partagent le fil neutre ou ne d placer aucun des deux 6 Lors du d placement de deux circuits partageant un fil neutre ceux ci doivent tre connect s sur des positions adjacentes l un au dessus de l autre au commutateur de transfert Cela garantira que les deux fils charg s sont sur des phases s par es et assurera le maintien de leur relation neutre 7 Choisir un circuit qui disposera d un dispositif de de secours et retirer le fil d alimentation du disjoncteur 15 Amp to 15 Amp 20 Amp to 20 Amp 8 l aide de coinceurs a c ble homologu s UL reconnecter le fil d alimentation un disjoncteur correspondant du commutateur de transfert 11 5 assurer que chaque circuit d plac est en par un disjoncteur de m me taille sur le commutateur de transfert Les circuits de 15 A doivent tre connect s des disjoncteurs de 15 A et les circuits de 20 A des disjoncteurs de 20 A 10 Connecter le long fil neutre fourni la barre neutre du panneau de distribution Installer un disjoncteur bipolaire sur le panneau de d
44. 2 www activategen com er A If you already have your activation code wait 3 5 seconds for the next display ENTER ACTIVATION CODE Passcode TROUBLESHOOTING Display Reads Use ARROW keys to scroll and find the first number of your Activation Code Serial 123456789 Passcode Press ENTER to select Repeat this step until all digits have been EN entered Use ESCAPE to correct previous digits Display Reads Activation is complete when all digits are What happens if Wrong Passcode Try entered above and your screen shows this Again appears an Spa Reenter the activation code If a second _ Follow the controller prompts to continue attempt is unsuccessful check the number setting the time function Refer to your against the code given on activategen com escape A W ener Owner s Manual with questions it is correct and the generator will not accept it contact 1 888 9ACTIVATE 922 8482 GENERATOR ma El SWITCH 1 If the generator comes with an external connection box and 5 seal tite whip pre wired and connected to the generator additional connections are necessary at the generator Skip the following section and proceed with Appendix A EZ Switch Installation amp Operational Testing 7 Remove the plastic plugs inside the main breaker access area to allow connection of the power leads to the circuit breaker aM AS
45. 20 210 209 56 56 818 C sl E IEEE 3E Ce EJ 0 0 14 05 T ALARM D de AA nd _______ 194 X BATTERY 23 SQ TRANSFER SP1 lt J M 18 13 13 13 LEGEND ae 1 BRUSH ASSEMBLY IN CB1 CIRCUIT BREAKER MAIN OUTPUT CB2 CIRCUIT BREAKER i CS CHOKE SOLENOID 0 FS FUEL SOLENOID HTO HIGH TEMPERATURE SWITCH IM_ IGNITION MODULE LOP LOW OIL PRESSURE SWITCH MOV VARISTOR SC STARTER CONTACTOR SCR STARTER CONTROL RELAY SM STARTER MOTOR SP_ SPARK PLUG o N 00 30 Wiring Diagram Schematic 20kW Drawing No 0H7570 A Electrical Data ENGINE COMPARTMENT N2B CONTROL PANEL A 7 2 28 OIL WARMER L 1 N1B 12 CN E 240Vac CONNECT OPTIONAL N2A N1A Y A HTz E _ T 8 44 44 Ey i 44 NM 00 E 11 2 44 O 6 1 00 2 11 4 GOVERNOR ACTUATOR 1121314 15161 7 8 9110 11 12 1314 NTA 2 N2A MAIN ON CONTROLLER SP2 Ue x FIELD BOOST m DIODE J4 e 1112131415161 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 SP1 lt gt 90 13 818 85 14 86 56 194 J1 817 819 820 210 18 209 23 23 194 209 210 820 817 818 819 0
46. 5 amp deben conectarse a circuitos que comparten el neutral o no mueva ninguno de interruptores de 15 ampreios y circuitos de 20 amps a ellos interruptores de 20 amperios 6 mover dos circuitos con un neutral compartido deber n 10 Conecte el neutral grande provisto a la barra neutral en el estar conectados a posiciones adyacentes una sobre la otra panel de distribuci n en el interruptor de transferencia Eso asegurar que los dos E cables calientes est n en fases separadas y mantendr n su relaci n con el neutral 11 Instale un interruptor de 2 polos en el panel de distribuci n para proteger al interruptor de transferencia El amperaje nominal requerido del interruptor depende del interruptor de 7 Elija un circuito a ser respaldado y retire la punta de energ a transferencia que se use El centro de carga procableado del interruptor conmuta el interruptor y no puede exceder los 70 amperios Este interruptor debe ser compatible con el panel de distribuci n el ctrica existente Instale el interruptor en dos ranuras vac as adyacentes una encima de la otra en el panel principal AE WS u gi i D pen 15 Amp to 15 Amp 20 Amp to 20 Amp 8 Usando tuercas de cable listadas UL reconecte la punta de energ a al interruptor apareado en el interruptor de transferencia 47 12 Cuando todos los circuitos de prioridad hayan sido movidos al interruptor de transferencia cier
47. Estas ubicaciones del dispositivo de eliminaci n son las nicas ubicaciones en las que el conducto deber estar unida a la caja Un taco de tierra se proporciona dentro de la caja con el fin de conectar a tierra al conducto CONEXI N DEL M DULO DE CORTE DE ALIMENTACI N LSM A El LSM puede controlar un aire acondicionado 24 VAC directamente o un contactor separado 120 VAC que puede controlar cualquier carga conectada a l ver figura Secuencia de operaci n Los 4 LEDs verdes de estatus indicar n cuando un nivel de prioridad de carga est habilitado e Todas las cargas est n habilitadas cuando la se al de transferencia est apagada ATS en posici n de servicio p blico Si la se al de transferencia est abajo activa e Todas las cargas est n habilitadas hasta que se detecte una sobrecarga Cuando se detecta una sobrecarga todas las cargas se desh abilitan Luego de 5 minutos las cargas de prioridad 1 se habilitan Luego de otros 30 segundos las cargas de prioridad 2 se habilitan Luego de otros 30 segundos las cargas de prioridad 3 se habilitan Luego de otros 30 segundos las cargas de prioridad 4 se habilitan Si se detecta una sobrecarga dentro de los 30 segundos de habilitar un nivel todas las cargas se deshabilitan otra vez y la secuencia se repite Sin embargo el nivel que caus la sobrecarga y todos los niveles mayores no ser n habilitados nuevamente por 30 minutos Control de carga de aire
48. INE 8 FRAME O GND 0 31 Electrical Data Electrical Schematic 20kW Drawing No 0G8515 A 240V GENERATOR CUSTOMER CONNECT AREA OUTPUT TO TRANSFER SWITCH CONTACTOR TRANS SIG 1 2 o 23 00000 0 0 00 WHT 33 Pt pp a EE 11 0 11C N1A o Lll 2 B 120V 15A N1A DUPLEX N2A LEGEND BA BRUSH ASSEMBLY 223 Ll L1 GREEN SYSTEM READY CB1 CIRCUIT BREAKER MAIN OUTPUT 194 L2 YELLOW MAINTENANCE REQD BREAKER L3 RED ALARM HTO HIGH TEMPERATURE SWITCH 209 _ IGNITON MODULE 510 LED BOARD LOW OIL PRESSURE SWITCH MOV VARISTOR A 2 S 3L 213 MERE TE SC STARTER CONTACTOR 817 SCR STARTER CONTROL RELAY 818 OY SM STARTER MOTOR ___819 SP SPARK PLUG SPLICE DISCONNECT SPLICE IC x lt 2 1 _ a x 0 240Vac CONNECT BATTERY BLACK WARMER RED UPTIDNAL d 0 NOTE ALL WRES 18 AWG 500V UL LISTED UNLESS SHOWN OTHERWISE BATTERY SIZE 121 32 Electrical Schematic 20kW Drawing No 0G8515 A Electrical Data 44 09 240 VAC GENERATOR OUTPUT 11 44 WINDING 33 EXCITATION pou peri 22 6 WINDING BATTERY WARMER CA NEUTRAL LS 07742
49. INSTALLATION GUIDELINES Air cooled Generators TABLE OF CONTENTS loa PPPoE e En sus Inside Front Cover Read this Manual Thoroughly IFC Contents n nT 1 Operation and 1 How to Obtain SO 1 s Hl e UU OO UTEM 1 E PP ee EU E 3 Unpacking Inspection aa 3 Protection SSI M den a tu 3 Requirement for Arc Fault Circuit Interruption Breaker for Bedrooms erario 3 Section 210 12 Arc Fault Circuit Interrupter Protection 3 TOL D CIN ensenada 4 Site Preparation and Generator Placement 4 Coverting to LP Vapor urraca id 5 Installing amp Connecting Gas 6 External Electrical GConnections 7 Generator ACA as 7 nice O E 8 Generator Connections EZ Switch 9 Appendix EZ Switch Installation amp Operational Testing 10 Battery Installation 12 Operational 12 Appendix B RTSX and RTSD Transfer Switch Installation amp Operational Testing 14 Selected Circuit Goverage 15 Whole house Circuit Coverage 15 Electrical Connections
50. OMBUSTIBLE LIQUIDS CODE disponible igual que el 1 PELIGRO Solo electricistas o contratistas calificados deber n intentar estas instalaciones que deben cumplir estrictamente con los c digos est ndares y regulaciones aplicables DESEMPAQUE INSPECCION Luego del desempaque inspeccione cuidadosamente si hay da os en el contenido Este generador de respaldo est listo para su instalaci n con una almohadilla base pre montada y proporcionada de f brica y tiene una caja protectora contra el clima que est dise ada para la instalaci n en exteriores solamente Este generador de respaldo listado por la UL puede empacarse con un interruptor de transferencia autom tica con un centro de cargas incorporado La combinaci n de interruptor de transferencia y centro de cargas est pre cableada con un conductor de dos pies y 30 pies Los interruptores de circuido para conexiones de circuito de emergencia est n incluidos si est equipado con ellos Este interruptor de dos polos listado en la UL nominalmente es de 1000 200 amperios AC a un m ximo de 250 voltios El interuptor de transferencia de 100 Amp es para uso en interiores nicamente El interruptor de transferencia de 200 Amp es para uso en exteriores interiores si est equipado con l AADVERTENCIA Si este generador se usa para energizar circuitos de carga el ctrica normalmente energizados por una fuente de energia de servicio publico el codigo
51. OUND HTO HIGH TEMPERATURE SWITCH IM IGNITON MODULE LOP LOW OIL PRESSURE SWITCH MOV VARISTOR SC STARTER CONTACTOR SCR STARTER CONTROL RELAY SM STARTER MOTOR SP_ SPARK PLUG SPLICE DISCONNECT SPLICE IC _ A A _ NAS 2 D 240Vac E 209 0 23 O 0 000 O O 22 33 ESL a Pit tp j U 11 ESE NAAA du Q0 EN 1 p T a Ll LL HL N2A 00 N2A pp L1 GREEN SYSTEM READY L2 YELLOW MAINTENANCE REQ D L3 RED ALARM 209 210 LED BOARD 820 20 E T T 810 1111 mal gt 1 0 0 BLACK RED 0 BATTERY 0 BATTERY WARMER OPTIONAL NOTE ALL WIRES 18 AWG 300V UL LISTED UNLESS SHOWN OTHERWISE AWG SIZE 121 29 Electrical Data Wiring Diagram Schematic 17kW Drawing No 0H6198 A 240 GENERATOR OUTPUT WINDING 11 44 ROTOR EXCITATION po 22 0 4 2 6 WINDING BATTERY WARMER NEUTRAL PAS D 240Vac Se D n CONNECT Toc 4 J 3 N2A OPTIONAL WARMER 0 4 2 OO WHT 240 VAC UTILITY N2 INPUT _ 120 VAC 52 1 00 120 00 X ACCESSORY POWER CONTROLLER PRINTED CIRCUIT BOARD 0 OUTPUT ix opp LED BOARD 817 819 8
52. Prueba de instalaci n y operaci n aa 50 Cobertura de circuito 51 Cobertura de circuito de casa completa 51 Conexiones el ctricas 51 de OMe dC 52 Ap ndice Administraci n de carga digital Digital Load MAO u uu u uu u 54 Ap ndice D M dulos de administraci n de carga digital Digital Load Managment DLM 55 Conexi n del m dulo de corte de alimentaci n Ism 55 Ap ndice Fijando la funci n de ejercicio autom tico 56 VIENTO RON 57 36 INTRODUCCION Gracias por comprar este generador compacto impulsado por motor refrigerado por aire de alto rendimiento Est dise ado para proveer energ a el ctrica en forma autom tica para operar cargas cr ticas durante una falla de la electricidad comercial Esta unidad est instalada de f brica en una caja metalica para todo clima prevista exclusivamente para su instalaci n en exteriores Este generador operar usando ya sea propano l quido en vapor LP o gas natural GN NOTA Este generador es adecuado para suministrar car gas residenciales t picas como motores de induc ci n bombas refrigeradores aires acondicionados chimeneas etc componentes electr nicos com putadoras monitores televisores
53. THE AUTOMATIC EXERLISE FUNCTION The display will enter an Installation Assistant mode when battery power 15 first connected The assistant will prompt to first enter the current date and time followed by the exercise day and time If the battery is ever disconnected and reconnected or fuse removed and replaced the Installation Assistant will be displayed again but only the current date and time will need to be entered 3 lf the exercise time day ever needs to be changed press the escape key to access the main menu 4 Press the left or right arrow key until Edit is flashing and press enter 9 Press the right or left arrow key until the exercise time is displayed and press enter 6 Using the arrow and enter keys first set the exercise hour in 24 hour format followed by the minute and finally the day 7 Once set the generator will exercise each week at the same time Be sure to show the owners how to set the exercise function for the day and time they want the unit to exercise 8 Ifthe generator is equipped with the low speed exercise feature it was enabled at the factory and no adjustment is needed Every installation has its own unique set of circumstances and requirements This booklet provides guidelines for basic installations only and is not intended to cover all applications If there are any questions or concerns after carefully reading all documentation received with the equipment contact the nearest dealer fo
54. UNCIONAMIENTO Y AJUSTES Luego de la instalaci n e interconexi n del interruptor de transferencia inspeccione la instalaci n completa con cuidado Un electricista competente y calificado deber hacer la inspecci n La instalaci n debe cumplir estrictamente todos los c digos est ndares y regulaciones aplicables Cuando est completamente seguro de que la instalaci n es la apropiada y correcta complete una prueba funcional del sistema 96 Calentador de agua UTILITY SOURCE CONNECTIONS N2_ Cia Ens MODULO P ES pF ier DLM EE 35 FREEZER LA AE TBA e HALL a at NACE EOS RE fwarer Outdoor la RA i f E En EI HE ER 212 212 6 02 21 2 21211 El E2 2 faa l I
55. YSTEMS FOR HEALTH CARE FACILITIES available same as ltem 1 3 54 NATIONAL FUEL GAS CODE available same as Item 1 4 NFPA No 58 AMERICAN NATIONAL STANDARD FOR STORAGE AND HANDLING OF LIQUEFIED PETROLEUM GAS available same as ltem 1 5 No 70 NFPA HANDBOOK OF NATIONAL ELECTRIC CODE available same as Item 1 6 Article X NATIONAL BUILDING CODE available from the American Insurance Association 85 John Street New York N Y 10038 7 AGRICULTURAL WIRING HANDBOOK available from the Food and Energy Council 909 University Avenue Columbia MO 65201 8 ASAE EP 3634 INSTALLATION AND MAINTENANCE OF FARM STANDBY ELECTRICAL SYSTEMS available from the American Society of Agricultural Engineers 2950 Niles Road St Joseph MI 49085 9 No 30 FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE available same as Item 1 DANGER Only qualified electricians or contractors should attempt such installations which must comply strictly with applicable codes standards and regulations UNPACKING INSPECTION After unpacking carefully inspect the contents for damage e This standby generator set is ready for installation with a factory supplied and pre mounted base pad and has a weather protective enclosure that is intended for outdoor installation only This UL listed standby generator set may be packaged with an automatic transfer switch with built in load center The combination transfer switch and lo
56. acteur s par est disponible chez le fabricant Si un relais diff rent est utilis il doit avoir une bobine de tension de 120 Vca Le LSM fournit une nergie avec fusible 9 A de 120 Vca pour alimenter les bobines de contacteurs relais contacteur 1 2 3 ou 4 1 Monter le module de contact et brancher la charge aux contacts principaux 2 Connecter la bobine du contacteur aux bornes LSM d sir es contacteur 1 2 3 ou 4 sur le bornier 3 Connecter chaque contacteur de d lestage suppl mentaire de la m me facon REMARQUE Il sera n cessaire de d terminer l ordre de d lestage des charges connect es et de connecter les quipements au LSM dans cet ordre 1 est la plus haute priorit et quatre est la plus faible priorit ATTENTION Effectuer les tests fonctionnels dans l ordre exact pr sent dans ce manuel sinon des dommages pourraient survenir au commutateur IMPORTANT Avant d effectuer les tests fonctionnels lire et s assurer que toutes les consignes et informations de cette section sont comprises Lire galement les informations et consignes figurant sur les tiquettes appos es sur le commutateur Noter toutes les options ou accessoires qui pourraient tre install s et revoir leur fonctionnement REMARQUE Ce test peut tre effectu avec le r seau public ou le g n rateur connect aux charges Cependant si le g n rateur fournit les charges et est surcharg il se peut que le cont
57. ad center is pre wired with a two foot and 30 foot conduit Circuit breakers for emergency circuit connections are included if equipped This UL listed 2 pole switch is rated at 100 or 200 AC amperes at 250 volts maximum The 100 Amp transfer switch is for indoor use only The 200 Amp transfer switch is for indoor outdoor use if equipped WARNING If this generator is used to power electrical load circuits normally powered by a utility power source it is required by code to install a transfer switch The transfer switch must effectively isolate the electrical system from the utility distribution system when the generator is operating NEC 700 701 amp 702 Failure to isolate an electrical system by such means will result in damage to the gen erator and also may result in injury or death to utility power workers due to backfeed of electrical energy If any loss or damage is noted at time of delivery have the person s making the delivery note all damage on the freight bill or affix their signature under the consignor s memo of loss or damage If a loss or damage is noted after delivery separate the damaged materials and contact the carrier for claim procedures Concealed damage is understood to mean damage to the contents of a package that is not in evidence at the time of delivery but is discovered later To properly open the roof press down on the center top lip and release the latch If pressure is not applied fr
58. ain contacts to the standby power generator position NEVER OPERATE THE TRANSFER SWITCH MANUALLY WHEN LOADS ARE CONNECTED 7 Put the generator s mode switch in MANUAL to start the engine Allow the engine to warm up then switch the generator s main breaker to the ON position The generator is now supplying electricity to the transfer switch but is not carrying any load 8 Check to be sure that voltage and frequency from the generator is correct If line to line voltage is not approximately i 240 volts refer to the generator Owner s Manual for the 12 Switch the generator s main breaker to the ON position and proper adjustment procedures If line to neutral voltage 15 put the mode switch in AUTO not approximately 120 volts check the neutral connection between the generator and transfer switch 13 Shut OFF utility power and make sure the generator starts automatically after the line interrupt delay 17 Switch the utility breaker ON to restore utility power to the home 15 Shut OFF utility power again to automatically start the generator When power has transferred to the generator close each of the breakers in the distribution panel one at a time until the generator has accepted the entire load 16 With the generator carrying the entire load recheck gas pressure to verify that it s at the same level it was before the generator was started NOTE Even if the generator is running smoothly at this
59. al se mostrar NO ACTIVADO Necesitar reconectar la bater a y empezar con el Paso La pantalla dice Si no tiene su c digo de activaci n vaya a www activategen com o llame al 1 888 9ACTIVATE 922 8482 www activategen com gt T Si ya tiene su c digo de activaci n espere de 3 a 5 segundos la siguiente pantalla EMV INGRESAR C DIGO DE ACTIVACI N contrase a DETECCI N DE FALLAS La pantalla dice Use las teclas de FLECHA para navegar y encontrar el primer n mero de su c digo de Serie 123456789 activaci n A Presione ENTER para seleccionar Repita este paso hasta que todos los d gitos ESTA hayan sido ingresados Use ESCAPE para corregir los d gitos anteriores La pantalla dice La activaci n est completa cuando todos Qu sucede si aparece contrase a errada los d gitos se hayan ingresado arriba y su intente nuevamente pantala muestra esto Reingrese el c digo de activaci n Si un Siga los pedidos del controlador para seguir segundo intento es infructuoso revise configurando la funci n de tiempo Consulte el n mero contra el c digo entregado escape A W su manual del propietario si tiene preguntas en activategen com Si es correcto y el generador no lo acepta p ngase en contacto con el 1 888 9ACTIVATE 922 8482 44 CONEXIONES DEL GENERADOR INTERRUPTOR EZ 1 Si el generador viene con una caja de conexi n externa y l tigo de sellado fue
60. allways providing AFCI protection on the complete circuit would comply with 210 12 If during the installation of the home standby system the decision is made to provide back up power to a bedroom branch circuit then the circuit breaker in the transfer switch should be replaced with an Arc Fault Circuit Interrupter It is most important that breakers only be switched like for like For instance if replacing a 15A breaker it MUST be replaced with a 15A AFCI breaker Likewise a 20A breaker MUST be replaced with a 20A AFCI These AFCI breakers are available at the nearest hardware store siemens Item Description Q115AF 15A Single Pole Q120AF 20A Single Pole BEFORE YOU BEGIN Contact the local inspector or City Hall to be aware of all federal state and local codes that could impact the installation Secure all required permits before starting the job Carefully read and follow all of the procedures and safety precautions detailed in the installation guide If any portion of the installation manual technical manual or other factory supplied documents is not completely understood contact a dealer for assistance Fully comply with all relevant NEC NFPA and OSHA standards as well as all federal state and local building and electric codes As with any generator this unit must be installed in accordance with current NFPA 37 and NFPA 70 standards as well as any other federal state and local codes for minimum distanc
61. anel principal 1 Elgenerador alimenta s lo circuitos designados que est n agrupados y cableados en un panel de distribuci n de prioridad separado El interruptor de transferencia est instalado entre el panel de distribuci n principal y el panel de prioridad El amperaje nominal del interruptor de transferencia debe ser igual o mayor que el m s alto amperaje nominal del servicio p blico y los interruptores del generador que alimentan el interruptor COBERTURA DE CIRCUITO DE CASA COMPLETA H Aislamiento total 3 La tierra que est normalmente en el panel principal debe conseguirse en el interruptor nominal de servicio y debe estar desconectada en el panel de distribuci n existente Consulte el C digo El ctrico Nacional NEC para una informaci n completa sobre conexi n a tierra y ajustes CONEXIONES EL CTRICAS Panel principal Desconexi n del servicio 1 El generador estar respaldando todas las cargas el ctricas dentro del panel de modo que el amperaje nominal del interruptor de transferencia debe ser igual o mayor que el amperaje nominal del servicio p blico normal A menos que se use un interruptor de transferencia nominal para servicio se debe ubicar una desconexi n de servicio principal antes del interruptor de transferencia El interruptor de transferencia debe ser instalado entre la entrada del servicio p blico y el panel de distribuci n del edificio 1 Conecte l
62. ape ni haga nada que pueda volver inseguro al sistema o que no cumpla con los c digos y est ndares aplicables Instale una alarma de mon xido de carbono operada con bater as en los interiores de acuerdo a las recomendaciones e instrucciones del fabricante El flujo adecuado y sin obstrucciones de aire para ventilaci n y refrigeraci n es cr tico para la correcta operaci n del generador No altere la instalaci n ni permita que haya siquiera un bloqueo parcial de la provisi n de ventilaci n ya que esto puede afectar seriamente la operaci n segura del generador El generador DEBE ser instalado y operado s lo en exteriores Mantenga las manos pies ropa etc lejos de las correas de tracci n ventiladores y otras partes m viles o calientes Nunca retire correa de tracci n alguna o protecci n de ventilador mientras la unida est operando Al trabajar con este equipo mant ngase alerta en todo momento Nunca trabaje en el equipo cuando est f sica o mentalmente fatigado Inspeccione el generador con regularidad y p ngase en contacto con el concesionario m s cercano si necesita repararlo 0 conseguir repuestos Antes de realizar cualquier mantenimiento al generador desconecte los cables de su bater a para evitar un arranque accidental Desconecte primero el cable del borne de la bater a indicado como NEGATIVO NEG o y luego retire el cable POSITIVO POS o Al reconectar los cables conecte el cable POSITIVO primero
63. arburant Laisser assez d espace autour du site pour l acc s d entretien consulter le code local et le placer une hauteur suffisante pour que l eau puisse atteindre le g n rateur Choisir un espace ouvert qui fournira un d bit d air ad quat et libre voir la section Emplacement dans le manuel d entretien 2 Placer l unit de mani re ce que les grilles d a ration ne soient pas obstru es par des feuilles de l herbe de la neige ou des d bris 5 assurer que les fum es d chappement n entreront pas dans le b timent par les avant toits les fen tres les ventilateurs soufflants ou autres admissions d air 64 Creuser un trou rectangulaire d environ cing pouces de profondeur et d environ six pouces plus longs et plus larges que l empreinte du g n rateur Couvrir avec un film de polyur thanne et remplir avec des gravillons ou des cailloux Compacter et niveler les cailloux Si vous le souhaitez il est possible de couler un massif en b ton Inspecter le g n rateur afin de s assurer qu il n y a pas eu de dommage pendant le transport et si n cessaire faire une r clamation aupres du transporteur Retirer les bandes qui maintiennent le g n rateur sur la palette en bois 5 assurer que l quipement de levage utilis a une capacit suffisante pour g rer de mani re s curis e le poids du g n rateur Utiliser les erses de levage en nylon et les raccorder aux ceillets de levage sur chaque coin du b t
64. as puntas de energ a desde el generador y el servicio p blico a las leng etas apropiadas en el interruptor de transferencia Las lenguetas est n claramente marcadas en el interruptor N Suministro p blico normal E Panel de conexi n del generador T Panel de distribuci n de carga 91 1 Si se instala el interruptor RTSD el servicio fue cambiado as que aseg rese de que las terminaciones est n bien antes de 2 Cables neutrales desde el servicio p blico y el generador volver a energizar el servicio p blico est n conectados la misma leng eta neutral en el interruptor 2 Apague el interruptor principal del servicio p blico Consulte al NFPA 70 E por el equipo de seguridad requerido al trabajar 3 Conecte los cables de control desde el generador al bloque dentro del interruptor de transferencia vivo terminal en el interruptor de transferencia Los terminales est n marcados N2 23 T1 y 194 o 158 3 Energice el servicio p blico y revise el voltaje l nea a l nea y l nea a neutro en los terminales N1 y N2 del contactor de transferencia Si el voltaje de l nea a l nea no es aproximadamente de 240 voltios desenergice la energ a p blica y revise las terminaciones entre el servicio p blico y N1 y N2 Si el voltaje de l nea a neutro no es aproximadamente 120 voltios desenergice la energ a p blica y revise las terminaciones neutrales Repita la misma revisi n de voltajes en los termina
65. circuito completo cumplir a con la 210 12 Si durante la instalaci n de un sistema de respaldo para la casa se toma la decision de proporcionar energ a de respaldo a un circuito ramal de dormitorio el interruptor de circuito en el interruptor de transferencia deber reemplazarse con un interruptor de circuito de falla de arco Es muy importante que los interruptores s lo se reemplacen con otro similar POr ejemplo si se reemplaza un interruptor de 15 DEBE ser reemplazado con un interruptor 15 Del mismo modo un interruptor de 204 DEBE ser reemplazado con un 204 Estos interruptores est n disponibles en la ferreter a m s cercana Siemens Descripci n Q115AF 15A polo nico Q120AF 20A polo nico 39 ANTES DE EMPEZAR Contacte al inspector local o a las autoridades para estar consciente de todos los c digos federales estatales y locales que pudieran impactar a la instalaci n Asegure todos los permisos requeridos antes de empezar el trabajo Lea cuidadosamente y siga todos los procedimientos y precauciones de seguridad detallados en la gu a de instalaci n Si cualquier parte del manual de instalaci n el manual t cnico u otros documentos proporcionados por la f brica no se entiende completamente contacte al concesionario Cumpla completamente con todos los est ndares relevantes de NEC NFPA y OSHA as como todos los c digos el ctricos
66. d circuits are transferred to the STANDBY generator power source To prevent possible injury if such a start and transfer occur always set the generator s AUTO OFF MANUAL Switch to its OFF position before working on equipment and remove the 15A fuse from the generator control panel In case of accident caused by electric shock immediately shut down the source of electrical power If this is not possible attempt to free the victim from the live conductor AVOID DIRECT CONTACT WITH THE VICTIM Use a nonconducting implement such as a dry rope or board to free the victim from the live conductor If the victim is unconscious apply first aid and get immediate medical help Never wear jewelry when working on this equipment Jewelry can conduct electricity resulting in electric shock or may get caught in moving components causing injury FIRE HAZARDS For fire safety the generator must be installed and maintained properly Installation must always comply with applicable codes standards laws and regulations Adhere strictly to local State and national electrical and building codes Comply with regulations the Occupational Safety and Health Administration OSHA has established Also ensure that the generator is installed in accordance with the manufacturer s instructions and recommendations Following proper installation do nothing that might alter a safe installation and render the unit in noncompliance with the aforementioned codes stan
67. dards laws and regulations Keep a fire extinguisher near the generator at all times Extinguishers rated ABC by the National Fire Protection Association are appropriate for use on the standby electric system Keep the extinguisher properly charged and be familiar with its use Consult the local fire department with any questions pertaining to fire extinguishers EXPLOSION HAZARDS Do not smoke around the generator Wipe up any fuel or oil spills immediately Ensure that no combustible materials are left in the generator compartment or on or near the generator as FIRE or EXPLOSION may result Keep the area surrounding the generator clean and free from debris Gaseous fluids such as natural gas and liquid propane LP gas are extremely EXPLOSIVE Install the fuel supply system according to applicable fuel gas codes Before placing the home Standby electric system into service fuel system lines must be properly purged and leak tested according to applicable code After installation inspect the fuel system periodically for leaks No leakage Is permitted STANDARDS INDEX In the absence of pertinent standards codes regulations and laws the published information listed below may be used as installation guide for this equipment 1 NFPA No 37 STATIONARY COMBUSTION ENGINES AND GAS TURBINES available from the National Fire Protection Association 470 Atlantic Avenue Boston 02210 2 No 76A ESSENTIAL ELECTRICAL S
68. de PL e Moteur GT 990 deux cylindres 13 kW de GN 13 kW de PL e Moteur GT 990 deux cylindres 13 kW de GN 14 kW de PL e Moteur GT 990 deux cylindres 16 kW de GN 16 kW de PL e Moteur GT 990 deux cylindres 16 kW de GN 17 kW de PL e Moteur GT 999 deux cylindres 18 kW de GN 20 kW de PL FONCTIONNEMENT ET MAINTENANCE L op rateur a la responsabilit d effectuer tous les contr les de s curit afin de s assurer que toute la maintenance pour le fonctionnement s r est effectu e rapidement et que l quipement est contr l r guli rement par un d positaire Le service de maintenance normal et le remplacement des pi ces sont la responsabilit du propri taire de l op rateur et en tant que tels ne sont pas consid r s comme des d fauts mat riels ou de fabrication selon les conditions de la garantie Les habitudes et usages de fonctionnement individuels contribuent la n cessit du service de maintenance La bonne maintenance et le bon entretien du g n rateur assurent un nombre minimal de probl mes et des d penses d exploitation minimales Consulter un d positaire pour obtenir des aides et des accessoires d entretien COMMENT OBTENIR LENTRETIEN Si un entretien ou des r parations sont n cessaires sur l quipement contacter un d positaire pour obtenir de l aide Les techniciens d entretien sont form s en usine et sont capables de g rer tous les besoins en entretien Lorsque vous contactez un d
69. depends on which transfer switch is used Pre wired load center switches the breaker cannot exceed 70 Amps This breaker must be compatible with the existing electrical distribution panel Install the breaker in two adjacent empty slots one above the other in the main panel WU M E a ng E to da 55 11 12 When all priority circuits have been moved to the transfer switch close the main breaker to restore utility power and make sure utility voltage at the transfer switch is correct Refer to NFPA 70 E for the safety equipment required when working inside a live transfer switch the generator Owner s Manual for a list of recommended batteries Follow all of the procedures and safety precautions in the 5 Manual when installing the battery BATTERY INSTALLATION 1 Before purchasing a battery for the generator refer to the Owner s Manual for the recommended battery e 8 kW Group 26R 12 350 minimum e 10 20 kW Group 268 12 Volt 525cca minimum 2 Follow all of the procedures and safety precautions in the generator Owner s Manual when installing the battery Verify the switch 15 in the off position When preparing for operational testing DO NOT connect the battery until transfer switch connections are complete OPERATIONAL TESTING 1 Switch the generator s main circuit breaker OFF and put th
70. dir et s arr ter automatiquement 15 Les tests op rationnels sont d sormais termin s Se reporter l Annexe E D finition de la fonction de programme de test automatique ANNEXE B INSTALLATION ET TEST OPERATIONNEL DU COMMUTATEUR DE TRANSFERT RTSX ET RTSD LEA D m E IS gt A 1 Avant de commencer l installation s assurer que l appareil est hors tension sur le panneau de distribution principal et lire attentivement le Manuel d entretien fourni avec le commutateur de transfert Pour simplifier le processus d installation le commutateur de transfert doit tre install aussi pr s que possible du panneau de distribution principal S assurer que ni l eau ni des substances corrosives ne coulent sur le bo tier du commutateur de transfert EU 4 2 Toujours inspecter le commutateur pour s assurer qu il n a pas subi de dommages pendant le transport Ne jamais monter un commutateur de transfert qui montre des signes de dommage 74 Prot ger le commutateur contre les impacts et le monter verticalement sur une structure de support rigide S assurer que le commutateur est niveau et d aplomb V rifier les codes locaux avant de brancher le commutateur de transfert Certaines juridictions exigent que le c blage situ a l int rieur du commutateur soit r alis par un lectricien agr Tout le c blage doit tre de la bonne taille et du type correct et doit tre confor
71. dule DLM peut tre install e l int rieur ou a l ext rieur Si l enveloppe est install e l ext rieur l orifice de vidange DOIT tre orient vers le bas Le module DLM est quip d emplacements d vacuation de conduit Ces emplacements d vacuation sont les seuls emplacements de l enveloppe auxquels le conduit doit tre fix Un plot de mise la terre est fourni a l int rieur de l enveloppe afin de connecter le conduit la terre BRANCHEMENT DES CONNEXIONS DU MODULE DE DELESTAGE LSM Le LSM peut contr ler un climatiseur 24 Vca directement ou un contacteur s par 120 Vca qui permet de contr ler toutes les charges connect es voir figure S quence de fonctionnement Les 4 voyants de statut verts indiquent que le niveau de priorit de charge est activ Toutes les charges sont activ es lorsque le signal de transfert est teint ATS en position Utility Si le signal de transfert est abaiss Actif Toutes les charges sont activ es jusqu a d tection d une surcharge Quand une surcharge est d tect e toutes les charges sont d sactiv es e Apr s 5 minutes les charges de priorit 1 sont activ es Apr s 30 secondes de plus les charges de priorit 2 sont activ es Apr s 30 secondes de plus les charges de priorit 3 sont activ es e Apr s 30 secondes de plus les charges de priorit 4 sont activ es Si une surcharge est d tect e dans les 30 secondes d un niveau activ t
72. e mode switch in the OFF position 2 Make sure utility power is OFF and place all of the priority circuit breakers in the transfer switch in the OFF position a E x LS p I 3 Locate the transfer handle insert the metal end into the slot in the main contactor assembly and pull the handle DOWN to move the main contacts to the standby power or generator position NEVER OPERATE THE TRANSFER SWITCH MANUALLY WHEN LOADS ARE CONNECTED 4 Put the generator s mode switch in MANUAL to start the engine Allow the engine to warm up then switch the generator s main breaker to the ON position The generator is now supplying electricity to the transfer switch but is not carrying any load 5 Be sure that voltage and frequency from the generator 15 correct If line to line voltage is not approximately 240 volts refer to the Owner s Manual for the proper adjustment procedures On all models if line to neutral voltage is not 120 volts check the neutral connection between the generator and transfer switch EE 6 When finished checking the voltage switch the generator s main circuit breaker OFF and put the mode switch in the OFF position to shut down the generator 7 Make sure the 2 pole circuit breaker installed in the main distribution panel is in the OFF position 8 Use the transfer handle to move the main contacts in the transf
73. e accompagn d un commutateur de transfert automatique avec centre de distribution int gr L association du commutateur de transfert et du centre de distribution est pr c bl e avec un conduit de c bles de deux pieds et de 30 pieds Des disjoncteurs pour les branchements du circuit de secours sont inclus le cas ch ant Cet interrupteur bipolaire certifi UL est concu pour 100 ou 200 amp res CA 250 volts maximum Le commutateur de transfert de 100 A est destin une utilisation l int rieur uniquement Le commutateur de transfert de 200 A est destin une utilisation l int rieur l ext rieur le cas ch ant AVERTISSEMENT Si ce g n rateur est utilis pour alimenter des circuits de charge lectriques normalement aliment s par une source d alimentation publique le code exige d installer un commutateur de transfert Le commutateur de transfert doit isoler de mani re efficace le syst me lectrique du syst me de distribution publique lorsque le g n rateur fonctionne NEC 700 701 et 702 Le fait de ne pas isoler un systeme lectrique par ces moyens endommagera le g n rateur et peut galement causer des blessures ou la mort pour les lectriciens due s la r alimentation de l nergie lectrique En cas de perte ou de dommage observ e lors de la livraison faire noter la aux personne s effectuant la livraison tout dommage sur la facture de transport ou les faire signer le documen
74. e main breaker to restore utility power and allow the engine to cool down and shut itself off 15 Operational tests are now complete Refer to Setting the Automatic Exercise Function to complete the installation APPENDIX B RTSX AND RTSD TRANSFER SWITCH INSTALLATION amp OPERATIONAL TESTING TE I y a A gt lt lt T 1 Before beginning any installation make sure power is shut OFF to the main distribution panel and carefully read the Owner s Manual that came with the transfer switch To simplify the installation process the transfer switch should be mounted as close to the main distribution panel as possible Make sure no water or corrosive substances can drip onto the transfer switch enclosure 2 Always inspect the switch for shipping damage Never mount a transfer switch that shows any evidence of damage 14 3 Protect against impact and mount the switch vertically to a rigid support structure Make sure the switch 15 level and plumb Check local codes before wiring the transfer switch Some jurisdictions require that wiring inside the switch be done by a licensed electrician 4 All wiring must be the correct size and type and must conform to all codes standards and regulations Refer to the transfer switch Owner s Manual and the National Electrical Code for additional information EE 5 with any product
75. e refroidissement et qu il S est arr t remettre le r seau public hors tension Lorsque le g n rateur alimente le commutateur de transfert d placer les disjoncteurs du commutateur sur la position ON Marche un par un jusqu ce que le g n rateur accepte la charge prioritaire complete 13 Le g n rateur portant la charge prioritaire compl te recontr ler la pression du gaz pour v rifier qu elle se trouve au niveau auquel elle se situait avant le d marrage du g n rateur REMARQUE M me si le g n rateur fonctionne correctement ce stade une baisse de la pression du gaz indique que l alimentation convient peine pour r pondre aux besoins du g n rateur Des modifications de la charge du g n rateur ou une demande de gaz suppl mentaire par d autres appareils peut affecter les performances du g n rateur V rifier la pression du gaz et la dimension des tuyaux D crocher le manometre et r installer la prise m le 14 Placer le disjoncteur principal sur la position ON Marche pour r tablir l alimentation du r seau public Le g n rateur continuera de fonctionner pour permettre au moteur de se refroidir avant de s arr ter automatiquement Remettre l alimentation du r seau public hors tension Le g n rateur doit d marrer et la charge prioritaire compl te doit tre transf r e vers le g n rateur Fermer le disjoncteur pour r tablir l alimentation du r seau public et laisser le moteur se refroi
76. ear el interruptor de transferencia Algunas jurisdicciones requieren que el cableado dentro del interruptor sea hecho por un electricista licenciado Todo el cableado debe ser del tipo y tama o correctos y debe cumplir todos los c digos est ndares y regulaciones Consulte el manual del propietario del interruptor de transferencia y el c digo el ctrico nacional para mayor informaci n B AA RA Como con cualquier producto pueden ocurrir cambios en el dise o en el tiempo de modo que consulte siempre los gr ficos en el manual del propietario del interruptor de transferencia para las conexiones requeridas y precauciones de seguridad 6 El interruptor de transferencia en uso es un interruptor de transici n abierta Los interruptores de transici n abierta m evitan la realimentaci n el ctrica entre el generador y el Aislamiento total servicio p blico permitiendo s lo que los circuitos de carga se conecten a una fuente de energ a a la vez COBERTURA DE CIRCUITO SELECCIONADO HH Aislamiento de circuito de respaldo Panel principal 2 Uninterruptor de transferencia nominal de servicio es instalado entre el servicio y el panel de distribuci n principal El interruptor nominal de servicio se vuelve el principal servicio de modo que no se necesita desconexi n del servicio El panel de distribuci n principal existente se convierte en un sub panel Panel de emergencia P
77. ecter les codes de construction et lectriques locaux d Etat et nationaux Conform ment aux r glementations l Occupational Safety and Health Administration OSHA Gestion de la s curit et la sant au travail a t tabli S assurer galement que le g n rateur est install conform ment aux instructions et aux recommandations du fabricant Apr s une bonne installation ne rien faire qui pourrait alt rer une installation s re et rendre l unit non conforme aux codes normes lois et r glementations susmentionn s e Garder un extincteur proximit du g n rateur tout moment Les extincteurs portant la mention ABC par la National Fire Protection Association Association nationale pour la protection contre les incendies sont adapt s une utilisation sur le syst me lectrique de secours Garder l extincteur correctement charg et se familiariser avec son utilisation Consulter les pompiers locaux en cas de questions relatives aux extincteurs RISQUES D EXPLOSION Ne pas fumer proximit du g n rateur Nettoyer imm diatement toute claboussure de carburant ou d huile S assurer qu aucune mati re combustible ne reste dans sur ou proximit du g n rateur tant donn que cela peut entrainer un INCENDIE ou une EXPLOSION Garder l espace environnant du g n rateur propre et sans d bris Les fluides gazeux tels que le gaz naturel et le propane liquide PL sont extr mement EXPLOSIFS Installer
78. ed off certain loads Depress the TEST button on the load controller This function will disconnect all loads controlled by the controller The load controller will then reconnect each load in a timed and staggered manner as described in the Transfer Switch Owner s Manual FUNCTIONAL TESTS AND ADJUSTMENTS Following transfer switch installation and interconnection inspect the entire installation carefully A competent qualified electrician should inspect it The installation should comply strictly with all applicable codes standards and regulations When absolutely certain the installation is proper and correct complete a functional test of the system 20 Hot Water Heater e DLM MODULE 1002224 GENERATOR SOURCE El e E2 APPENDIX E SETTING
79. ego de instalar este sistema de respaldo el ctrico dom stico el generador puede arrancar en cualquier momento sin advertencia Cuando esto ocurra los circuitos de carga son transferidos a la fuente de energ a de RESPALDO generador Para evitar da os posibles si ocurren tales arranques y transferencias siempre coloque el interruptor de AUTO OFF MANUAL del generador en su posici n OFF antes de trabajar en el equipo y retire los fusibles de 15 del panel de control del generador En caso de un accidente causado por descarga el ctrica apague inmediatamente la fuente de energ a el ctrica Si esto no es posible intente liberar a la v ctima del conductor vivo EVITE EL CONTACTO DIRECTO CON LA VICTIMA Une un implemento no conductivo como una soga seca o una tabla para liberar a la v ctima del conductor vivo Si la v ctima est inconsciente aplique los primeros auxilios y consiga ayuda m dica inmediatamente Nunca use joyas al trabajar con este equipo Las joyas pueden conducir electricidad y traer como resultado una descarga el ctrica o puede quedar atrapada en los componentes m viles PELIGRO DE INCENDIO Para mayor seguridad contra incendios el generador debe instalarse y mantenerse en forma apropiada La instalaci n debe siempre cumplir con los c digos est ndares leyes y regulaciones aplicables Adhi rase esctrictamente a los c digos nacionales estatales y locales de electricidad y construcci n Cumpla con las r
80. ego gire en sentido horario 909 y deje regresar al selector una vez que est alineado con la posici n de LP LN Palanca de selecci n de combustible posici n para gas natural ES 255 Z N SS d _ _ EL ta 3 En las unidades de 10 kW abra el techo suelte la abrazadera delantera de la manguera de entrada y desl ce la manguera lejos del accesorio de la manguera y Palanca de selecci n de combustible Posici n para propano l quido Deslice el pasador del selector de combustible sobre el carburador afuera hacia la parte de atr s de la caja Reemplace la maguera de entrada y ajuste la abrazadera en forma segura Palanca de selecci n de combustible Posici n fuera para gas propano l quido E En todos los otros modelos simplemente retire la cubierta del limpiador de aire y deslice el pasador del selector de combustible hacia afuera desde la posici n de gas natural a la de LP 41 INSTALACION Y CONEXION DE LINEAS DE GAS 1 2 3 42 El gas natural y el vapor de LP son substancias ltamente vol tiles de modo que es escencial la estricta adhesi n atodos los procedimientos de seguridad est ndares y regulaciones Las conexiones de l nea de gas deber n ser efectuadas por un plomero certificado familiarizado con los c digos locales Use siempre una tuber a de gas aprobada por la AGA y un sellador o compu
81. egulaciones que la Administraci n de salud y seguridad ocupacional OSHA ha establecido Asimismo aseg rese de que el generador sea instalado de acuerdo con las instrucciones y recomendaciones del fabricante Luego de una instalaci n apropiada no haga nada que pueda alterar una segura instalaci n ni hacer que la unidad no cumpla con los mencionados c digos est ndares leyes y regulaciones Tenga un extinguidor cerca al generador en todo momento Los extinguidores marcados ABC por la Asociaci n nacional de protecci n contra incendios son los apropiados para usarse en los sistemas el ctricos de emergencia Mantenga el extinguidor apropiadamente cargado y familiaricese con su uso Consulte su departamento local de bomberos cualquier duda respecto a los extinguidores PELIGRO DE EXPLOSI N No fume alrededor del generador Limpie cualquier derrame de combustible o aceite inmediatamente Aseg rese de que no haya dejado materiales combustible en el compartimiento del generador en o cerca del generador ya que pueden causar INCENDIOS y o EXPLOSIONES Mantenga el rea circundante del generador limpia y libre de desperdicios Los fluidos gaseosos como el gas natural y el gas propano l quido GLP son extremadamente explosivos Instale el sistema de abastecimiento de combustible de acuerdo a los c digos aplicables para combustible y gas Antes de colocar el sistema de respaldo el ctrico de respaldo en servicio las l neas del sis
82. enerador El proveedor local de gas es responsable de asegurar una presi n adecuada de modo que si la presi n es demasiado baja o mayor que 14 pulgadas de columna de agua contacte a su proveedor de gas 3 Monte la caja de conexiones de modo que cubra completamente el agujero en la pared Masille alrededor de los lados y encima de la caja para asegurar un buen sello Conecte todos los cables a las orejas en la caja de conexi n negro con negro rojo con rojo y blanco con blanco Una el cable de tierra verde al tornillo de tierra y conecte los dos peque os conectores a sus respectivos recept culos ALTO POL TAE makis VLBCTRICAL COVER yet pe 7 Al finalizar la revisi n de la presi n gas cierre la v lvula manual de cierre CONEXIONES ELEGTRIGAS 4 Vuelva a colocar la placa cubierta protectora y tornillo de retenci n y cierre la caja de conexiones 1 Taladre un agujero de 1 de pulgada y alimente el conductor a trav s del agujero 9 Para modelos de 10 20 kW ubique el pestillo de metal que se empaca en la bolsa del manual del propietario Inserte el pestillo en la ranura ubicada a la izquierda de la caja de interruptores del circuito externo Aseg rese de que el pasador del pestillo mire hacie el frente del generador Si se desea cierre la caja externa ACTIVACI N DEL GENERADOR Cuando se aplica la energ a de la bater a al generador durante el proceso
83. enerator DANGER WARNING CAUTION and NOTE blocks are used to alert personnel to special instructions about a particular operation that may be hazardous if performed incorrectly or carelessly Observe them carefully Their definitions are as follows A DANGER INDICATES A HAZARDOUS SITUATION OR ACTION WHICH IF NOT AVOIDED WILL RESULT IN DEATH OR SERIOUS INJURY WARNING Indicates a hazardous situation or action which if not avoided could result in death or serious injury A CAUTION Indicates a hazardous situation or action which if not avoided could result in minor or moderate injury NOTE Notes contain additional information important to a procedure and will be found within the regular text body of this manual These safety warnings cannot eliminate the hazards that they indicate Common sense and strict compliance with the special instructions while performing the action or service are essential to preventing accidents Four commonly used safety symbols accompany the DANGER WARNING and CAUTION blocks The type of information each indicates 15 as follows This symbol points out important safety information that if not followed could endanger personal safety and or property of others This symbol points out potential explosion hazard This symbol points out potential fire hazard iy This symbol points out potential electrical shock hazard The operator is responsible for proper and safe use of t
84. ente acompa an los bloques de PELIGRO ADVERTENCIA y CUIDADO El tipo de informaci n que cada uno indica es como sigue Este s mbolo se ala importante informaci n de seguri dad que 51 no se sigue puede poner en peligro la segu ridad personal y o las propiedades de otros A Este s mbolo indica un peligro potencial de explosi n Este s mbolo indica un peligro potencial de incendio Este s mbolo indica un peligro potencial de choque el c trico El operador es responsable del uso apropiado y seguro de este equipo El fabricante recomienda encarecidamente que el operador lea este Manual de Propietario y entienda completamente todas las instrucciones antes de usar este equipo El fabricante asimismo recomienda con igual firmeza el instruir a otros usuarios para arrancar y operar apropiadamente la unidad Esto los prepara si necesitan operar el equipo en alguna emergencia CONTENIDO Este manual contiene informaci n pertinente al propietario de estos modelos e 7 KW NG 8 kW LP motor de un cilindro GH 410 e 9 kW NG 10 kW LP motor V twin GH 530 e 13kWNG 13 KW LP motor V twin GH 990 e 13 kW NG 14 kW LP motor V twin GH 990 e 16 kW 16 kW LP motor V twin GH 990 e 16 kW NG 17 kW LP motor V twin GH 990 18kWNG 20 kW LP motor V twin GH 999 OPERACI N Y MANTENIMIENTO Es responsabilidad del operador el realizar todos los chequeos de seguridad asegurarse de que se haya realizado adecuadamente todo el man
85. eptado la carga entera 16 Con el generador llevando la carga entera revise la presi n del gas para verificar que est al mismo nivel que estaba antes de que arranque el generador NOTA A n si el generador est funcionando sin problemas en este punto una ca da en la presi n del gas indica que el suministro es apenas adecuado para suministrar las necesidades del generador Cambios en la carga del generador o una demanda adicional de gas por otros aparatos pueden afectar el rendimiento del generador Verifique la presi n del gas y el tama o de la tuber a Desenganche el man metro y reinstale la tapa del puerto 17 Encienda el interruptor de servicio p blico para restaurar la energ a p blica al hogar 18 El generador continuar funcionando para permitir que el motor se enfr e luego se apaga solo 19 Apague la energ a p blica nuevamente El generador deber arrancar y la carga de prioridad entera deber transferirse al generador 20 Cierre el mum para restaurar la energ a p blica y deje que el motor enfr e y se apague Las pruebas de operaci n est n ahora completas Consulte el ap ndice E Configurando la funci n de ejercicio autom tico para completar la instalaci n APENDICE ADMINISTRACION DE CARGA DIGITAL DIGITAL LOAD MANAGMENT DLM Para controlar un acondicionador de aire conecte el terminal Y del termostato a uno de los terminales A C 1 Conecte el otro terminal A C 1 a
86. er switch to the UP utility position Switch the 2 pole breaker ON in the distribution panel 9 Now switch the generator s main breaker ON and put the mode switch in AUTO automatically 11 If everything worked properly switch the main breaker to ON and make sure that power is automatically transferred back to the utility 12 After the engine has completed its cool down cycle and shut down shut OFF utility power again When the generator is supplying power to the transfer switch move the breakers in the switch to the ON position one at a time until the generator has accepted the entire priority load 13 With the generator carrying the entire priority load recheck gas pressure to verify that it is at the same level it was before the generator was started NOTE Even if the generator is running smoothly at this point a drop in gas pressure indicates that the supply is barely adequate to supply the generator s needs Changes in the generator load or additional gas demand by other appliances may affect the generator s performance Verify gas pressure and pipe sizing Unhook the manometer and reinstall the port plug 14 Switch the main breaker ON to restore utility power The generator will continue to run to allow the engine to cool down before shutting itself off Shut off utility power again The generator should start and the entire priority load should transfer to the generator Close th
87. eraci n Tenga mucho dado en las cercan as de los generadores en funcionamiento La instalaci n debe siempre cumplir con los c digos est ndares leyes y regulaciones apli cables Un generador en funcionamiento expele mon x ido de carbono un gas venenoso sin color ni aroma La inhalaci n de mon xido de carbono puede causar dolor de cabeza fatiga mareos n useas v mitos ataques o muerte ADVERTENCIA PROPOSICI N 65 DE CALIFORNIA El Estado de California sabe que el escape del motor y algunos de sus componentes causan c ncer defectos de nacimiento y otros da os reproductivos ADVERTENCIA PROPOSICI N 65 DE CALIFORNIA Este producto contiene o emite qu micos que el Estado de California sabe que causan c ncer defectos de nacimiento u otros da os reproductivos 37 30 PELIGROS GENERALES Por razones de seguridad el fabricante recomienda que a este equipo se le d servicio sea instalado y reparado por un concesionario de servicio u otro electricista calificado o un t cnico de instalaci n competente que est familiarizado con los c digos est ndares y regulaciones aplicables El operador tambi n debe cumplir estos c digos est ndares y regulaciones Los humos del escape del motor contienen mon xido de carbono que puede ser MORTAL Este gas peligroso si se aspira en concentraciones suficientes puede hacerle perder la conciencia y causarle la muerte NO altere ni agregue nada al sistema de esc
88. es from other structures SITE PREPARATION AND GENERATOR PLACEMENT 1 Locate the mounting area as close as possible to the transfer switch and fuel supply Leave adequate room around the area for service access check local code and place high enough to keep rising water from reaching the generator Choose an open space that will provide adequate and unobstructed airflow see the Location section in the Owner s Manual 2 Place the unit so air vents won t become clogged with leaves grass snow or debris Make sure exhaust fumes will not enter the building through eaves windows ventilation fans or other air intakes Dig a rectangular area approximately five inches deep and about six inches longer and wider than the footprint of the generator Cover with polyurethane film and fill with pea gravel or crushed stone Compact and level the stone concrete pad can be poured if desired Inspect the generator for shipping damage and if necessary file a claim with the shipper Remove the bands holding the generator to the wooden pallet 4 Make sure the lifting equipment to be used has sufficient capacity to safely handle the weight of the generator Use nylon lifting straps and connect them to the lifting eyes on each corner of the base frame to avoid damaging the enclosure Set the generator onto the pad so that the gravel bed extends several inches beyond the generator on all sides Make sure the genera
89. es recommand es e 8 kW groupe 268 12 volts et 350 ADF minimum e 10 20 kW groupe 26R 12 volts et 525 ADF minimum Suivre toutes les proc dures et pr cautions de s curit du Manuel d entretien du g n rateur lors de l installation de la batterie V rifier que l interrupteur se trouve sur la position OFF Arr t Lors de la pr paration du test op rationnel NE PAS connecter la batterie avant que les branchements du commutateur de transfert n aient t effectu s TEST OP RATIONNEL o Placer le disjoncteur principal du g n rateur et le s lecteur de mode sur la position OFF Arr t 2 S assurer que l alimentation du r seau public est d sactiv e et placer tous les disjoncteurs prioritaires du commutateur de transfert sur la position OFF Arr t Localiser la poign e de transfert ins rer l extr mit en m tal dans la fente du contacteur principal et tirer la poign e VERS LE BAS pour d placer les principaux contacts vers la position de l alimentation de Secours ou la position du g n rateur NE JAMAIS UTILISER LE COMMUTATEUR DE TRANSFERT MANUELLEMENT LORSQUE DES CHARGES SONT CONNECTEES Mettre le s lecteur de mode du g n rateur sur la position MANUAL Manuel pour d marrer le moteur Laisser chauffer le moteur puis placer le disjoncteur principal du g n rateur sur la position ON Marche Le g n rateur alimente maintenant le commutateur de transfert mais ne porte pas de charge 5
90. estas REGLAS DE SEGURIDAD con cuidado antes de instalar operar o dar servicio a este equipo Familiaricese con este Manual del propietario y con la unidad El generador puede operar en forma segura eficiente y confiable s lo si se le instala se le opera y mantiene en forma apropiada Muchos accidentes son causados por no seguir reglas 0 precauciones simples y fundamentales El fabricante no puede anticipar todas las posibles circunstancias que puedan involucrar peligros Las advertencias en este manual y en las etiquetas y calcoman as fijadas en la unidad son por tanto no completamente inclusivas Si se usa un procedimiento m todo de trabajo o t cnica de operaci n que el fabricante no recomienda espec ficamente aseg rese de que sea seguro para los dem s Asimismo aseg rese que el procedimiento m todo de trabajo o t cnica de operaci n utilizada no vuelva inseguro al generador PELIGRO A despecho del muy seguro dise o de este generador el operar este equipo en forma imprudente con deficiente mantenimiento o en forma descuidada puede causar posibles da os o la muerte Permita s lo que personas responsables y capaces instalen operen y den mantenimiento a este equipo NE m quinas generan voltajes potencial mente letales Aseg rese de que se haya toma do todos los pasos para hacer la m quina segu ra antes de intentar trabajar en el generador Partes del generador est n girando y o cali entes durante la op
91. esto para justas de tuber a de calidad Verique la capacidad del medidor de gas natural o el tanque de LP respecto a proporciona el combustible suficiente para el generador y otros dispositivos operativos c La mayor a de aplicaciones requerir n una v lvula de cierre manual externa en la l nea de combustible En el lugar en que la l nea de gas ingresa al generador instale un accesorio en para el monitoreo de la presi n gas En una abertura del accesorio instale un chup n de Y y una tapa roscada En algunos casos se puede instalar una trampa de sedimentos Al conectar la l nea de gas al generador use la secci n proporcionada de l nea de combustible flexible aprobada por la AGA y listada en la UL de acuerdo con las regulaciones locales El prop sito de la l nea flexible de combustible es asegurar que la vibraci n del generador no cause una fuga de gas en uno de los puntos de conexi n de modo que es importante que la l nea se instale con la menor cantidad posible de dobleces Nunca doble la l nea flexible de combustible para evitar usar un codo El doblar una l nea flexible disminuye su capacidad de absorber vibraciones y frustra su prop sito as como constri e su flujo real de combustible Luego de revisar si hay fugas revise la presi n del gas en el accesorio instalado anteriormente para asegurarse de que exista presi n suficiente para una apropiada operaci n del g
92. ettre hors tension l alimentation du r seau public et v rifier les raccordements neutres R aliser les m mes v rifications de la tension au niveau des bornes T1 et T2 pour s assurer que le courant circule correctement travers le contacteur 5 En veillant soutenir les cosses serrer les cosses du commutateur de transfert aux couples indiqu s sur le commutateur de transfert l tiquette est situ e l int rieur de la porte du commutateur 76 4 Placer le disjoncteur principal du g n rateur et le s lecteur de mode sur la position OFF Arr t 9 Placer le disjoncteur principal du g n rateur et le s lecteur de mode sur la position OFF Arr t pour teindre le g n rateur 5 S assurer que l alimentation du r seau public est hors tension et placer tous les disjoncteurs individuels du panneau de distribution sur la position OFF Arr t merren amem oa m o o 10 Lalimentation du r seau public toujours hors tension utiliser la poign e de transfert pour d placer les principaux contacts vers la position UP r seau public 6 Localiser la poign e de transfert ins rer l extr mit en m tal dans la fente du contacteur principal Tirer la poign e VERS LE BAS pour d placer les principaux contacts vers la position de l alimentation de secours g n rateur NE JAMAIS UTILISER LE COMMUTATEUR DE TRANSFERT MANUELLEMENT LORSQUE DES CHARGES SONT CONNECT ES 7
93. event electrical feedback between the generator and the utility by only allowing load circuits to be connected to one power supply at a time 4 Each wire in the pre wired transfer switch is color coded to easily match circuits in the main panel to their new breakers in the transfer switch Move Both Circuits ES Don t q 4 When three conductor wiring is two 120 volt circuits will often share the same neutral wire To avoid overloading the neutral either move BOTH of the circuits that share the neutral or don t move either of them When moving two circuits with a shared neutral they should be connected to adjacent positions one above the other in the transfer switch That will assure that the two hot wires are on separate phases and will maintain their relationship to neutral Choose a Circuit to be backed up and remove the power lead from the breaker 15 Amp to 15 Amp 20 Amp to 20 Amp Using UL Listed wire nuts reconnect the power lead to a matching breaker in the transfer switch 9 Make sure each circuit moved is protected by the same size breaker in the transfer switch 15 Amp circuits must be connected to 15 Amp breakers and 20 Amp circuits to 20 Amp breakers 10 Connect the provided large neutral to the neutral bar in the distribution panel 11 Install a 2 pole breaker in the distribution panel to protect the transfer switch The required amp rating of the breaker
94. gue d sir e Appuyez sur ENTREE pour s lectionner Appuyez sur ENTR E pour commencer le processus d activation Si vous ne disposez de code d activation allez sur www activategen com ou appelez le 1 888 9ACTIVATE 922 8482 Si vous avez d j votre code d activation attendez 3 5 secondes pour l affichage suivant Si la mauvaise langue est choisie elle peut tre chang e plus tard dans le menu Edition Si vous appuyez sur CHAP ou lieu d ENTR E votre g n rateur ne fonctionnera qu en mode manuel des fins de test et NON ACTIV s affiche Dans ce cas vous devez reconnecter la batterie et recommencer l tape 1 ENTRER CODE D ACTIVATION code d acces D PANNAGE L cran indique S rie 123456789 Code d acc s XXXXX e TA Y Yes L cran indique S LECTIONNER L HEURE 0 23 gt 6 gt o Y 68 Utilisez les TOUCHES de direction pour trouver le premier chiffre de votre code d activation Appuyez sur ENTREE pour s lectionner R p tez cette tape jusqu ce que tous les chiffres soient entr s Utilisez la touche CHAP pour corriger les chiffres pr c dents L activation est termin e lorsque tous les chiffres sont inscrits en dessus et que votre cran affiche ceci Suivez les invites du contr leur pour poursuivre avec le r glage de la fonction de temps Pour toute question consultez votre manuel d utilisation Qu advient
95. he equipment The manufacturer strongly recommends that the operator read this Owner s Manual and thoroughly understand instructions before using this equipment The manufacturer also Strongly recommends instructing other users to properly start and operate the unit This prepares them if they need to operate the equipment in an emergency CONTENTS This manual contains pertinent owner s information for these models e 7 kW NG 8 kW LP single cylinder GH 410 Engine e 9 kW NG 10 kW LP V twin GT 530 Engine e 13 kW 13 kW LP V twin GT 990 Engine e 13 kW 14 kW LP V twin GT 990 Engine 16 kW 16 kW LP V twin GT 990 Engine e 16 kW NG 17 kW LP V twin GT 990 Engine e 18 kW 20 kW LP V twin GT 999 Engine OPERATION AND MAINTENANCE It is the operator s responsibility to perform all safety checks to make sure that all maintenance for safe operation is performed promptly and to have the equipment checked periodically by a Dealer Normal maintenance service and replacement of parts are the responsibility of the owner operator and as such are not considered defects in materials or workmanship within the terms of the warranty Individual operating habits and usage contribute to the need for maintenance service Proper maintenance and care of the generator ensures a minimum number of problems and keep operating expenses at a minimum oee a Dealer for service aids and accessories HOW TO OBTAIN SERVICE When
96. i de base afin d viter d endommager l enveloppe Placer le g n rateur sur le massif de mani re ce que le lit de gravier s tende de plusieurs pouces au del du g n rateur de tous les c t s 5 assurer que le g n rateur est niveau plus ou moins 0 5 pouce Brancher un conducteur de terre approuv une languette de masse sur le b ti de base et une prise de terre ou une tige la terre approuv e comme stipul par les r glementations locales V rifier l huile de moteur et si n cessaire ajouter assez d huile recommand e afin de mettre niveau la marque FULL Plein sur la jauge d huile Faire attention de ne pas trop remplir le carter Le g n rateur a t configur pour le fonctionnement au gaz naturel l usine Passer la vapeur PL est une proc dure simple Sur les modeles quip s d un moteur un cylindre commencer par d brancher et retirer la batterie si elle est install e 2 Prendre le s lecteur de carburant par la poign e en T en plastique dans l enveloppe en poly thyl ne fournie avec le g n rateur et localiser la languette du s lecteur sur le couvercle de boite vent Ins rer l extr mit de la goupille dans le trou dans la languette du s lecteur et tirer vers l ext rieur pour surmonter la pression du ressort Puis tourner dans le sens des aiguilles d une montre de 90 degr s et laisser le s lecteur revenir une fois align sur la position de PL
97. ible Never bend the flexible fuel line to avoid using an elbow Bending the flexible line decreases its ability to absorb vibrations and defeats its purpose as well as constricts the actual fuel flow After checking for leaks check the gas pressure at the T fitting installed earlier to make sure there s enough pressure for proper generator operation The local gas supplier is responsible for ensuring adequate pressure so if the pressure is too low or if it s greater than 14 inches of water column contact the gas supplier 7 When finished checking the gas pressure close the manual shutoff valve 2 Remove the knockout in the back of the connection box feed the wires through the back of the box and secure the with the lock nut Seal the hole with silicone caulk Don t forget to caulk the hole inside the house as well 3 Mount the connection box so that it completely covers the hole in the wall Caulk around the sides and top of the box to ensure a good seal Connect all wires to the lugs in the connection box black to black red to red and white to white Attach the green ground wire to the ground screw and connect the two small plugs to their mating receptacle ends kaa CH dr i 4 Replace the protective cover plate and retaining screw and lock the connection box in the 5 manual bag Insert the hasp in the slot located on the left side of the external circuit
98. ierra y d torque de hasta 35 libras pulg Los valores de torque son e 10 14 AWG 35 in lbs 8 AWG 40 in Ibs 4 6 AWG 114 30 cm lbs 45 1 Antes de emprezar cualquier instalaci n aseg rese que la energ a est apagada al panel de distribuci n principal y lea cuidadosamente el manual del propietario que vino con el interruptor de transferencia El interruptor del centro de cargas distribu das debe ser montado cerca del panel de distibuci n principal para acomodar el conducto precableado de dos pies Aseg rese de que no gotee agua ni sustancias corrosivas en la caja del interruptor de transferencia EN ene E Cx Gite o sms 10 2 Siempre inspeccione si tiene edam por re 10 Conect el cable neutro blanco a la barra de bus netural con embarque Nunca monte un interruptor de transferencia que torque de 35 pulg lb Los valores de torque son muestre alguna evidencia de da o e 10 14 AWG 35 in lbs 8 AWG 40 in Ibs 4 6 AWG 114 30 cm lbs 11 Conecte los cables de control a los terminales correctos Los terminales est n marcados claramente N1 N2 23 194 y T1 Si se conecta un interruptor pre cableado tambi n se requerir un cable 0 cero NOTA Con el fin de mantener la separaci n de circuitos los cables de control DC deben estar separados de los cables de control AC Un pedazo de manga de fibra de vidrio se ha proporcionado en el kit 3 Prot jalo
99. if et comprime le d bit actuel 6 Apr s s tre assur qu il n y a pas de fuite v rifier la pression de gaz au niveau du raccord en T install plus t t afin de s assurer qu il y a assez de pression pour le bon fonctionnement du g n rateur Le fournisseur de gaz local doit s assurer de la pression ad quate donc si la pression est trop basse ou si elle est sup rieure 14 pouces de colonne d eau contacter le fournisseur de gaz 7 Apr s avoir v rifi la pression de gaz fermer la soupape d arr t manuelle 2 Retirer la d bouchure de l arri re de la boite de jonction alimenter les fils travers l arri re de la boite et fixer le conduit l aide d un contre crou Sceller le trou avec de la p te de silicone Ne pas oublier de calfeutrer le trou l int rieur de la boite galement 3 Monter la bo te de jonction afin qu elle recouvre compl tement le trou dans le mur Calfeutrer autour des c t s et du haut de la boite afin d assurer une bonne tanch it Brancher tous les fils aux cosses dans la boite de jonction noir avec noir rouge avec rouge et blanc avec blanc Fixer le conducteur de terre vert la mise la terre visser et brancher les deux petites fiches leurs prises homologues ALTO ED Th E sana Da AT HLBCTRECRL DIM IR 4 Remplacer le couvre joint de protection et la vis de fixation et verrouiller la boite de jonction
100. ion on grounding and bonding ELECTRICAL CONNECTIONS t LS LNT La aria 1 The generator will be backing up all electrical loads within the panel so the amperage rating of the transfer switch must be equal to or greater than the amperage rating of the normal utility service Unless a service rated transfer switch is used a main service disconnect must be located before the transfer switch The transfer switch must be installed between the utility service entrance and the building distribution panel 1 Connect the power leads from both the generator and the utility to the appropriate lugs in the transfer switch The lugs are clearly marked in the switch N Normal Utility Supply E Generator Connection Panel T Load Distribution Panel 2 3 4 9 Neutral wires from both the utility and the generator are connected to the same neutral lug in the switch i Connect the control wires from the generator to the terminal block in the transfer switch The terminals are marked N1 N2 23 T1 and 194 158 Complete the transfer switch wiring by connecting the equipment ground wires from both the utility and the generator to the ground lug Being careful to support the lugs torque the lugs in the transfer switch to the specifications shown on the transfer switch Decal located on the inside of the switch door OPERATIONAL TESTING
101. istribution pour prot ger le commutateur de transfert L intensit nominale requise pour le disjoncteur d pend du type de commutateur de transfert utilis Pour les commutateurs pr cabl s du centre de distribution le disjoncteur ne peut d passer 70 A Ce disjoncteur doit tre compatible avec le panneau de distribution lectrique existant Installer le disjoncteur sur deux fentes vides adjacentes l une au dessus de l autre du panneau principal 2 y lt m M UAM TPE e a mk 3 H EN 4 d to NFPA gt 12 Lorsque tous les circuits prioritaires ont t d plac s sur le commutateur de transfert refermer le disjoncteur principal pour r tablir l alimentation du r seau public et s assurer que la tension du r seau public est correcte au niveau du commutateur de transfert Se reporter a la norme 70 E pour conna tre l quipement de s curit n cessaire lors d un travail l int rieur d un commutateur de transfert 2 13 Avant d acheter une batterie pour le g n rateur se reporter au Manuel d entretien du g n rateur pour consulter une liste des batteries recommand es Suivre toutes les proc dures et pr cautions de s curit du Manuel d entretien lors de l installation de la batterie INSTALLATION DE LA BATTERIE 1 12 Avant d acheter une batterie pour le g n rateur reporter au Manuel d entretien pour conna tre les batteri
102. l terminal Y del aire acondicionado Use cable de cobre 18 26 AWG Consulte el manual propietario para los requerimientos espec ficos de torque y conexi n 2 Para controlar un segundo aire acondicionado haga lo mismo usando los terminales marcados A C 2 NOTA Para informaci n espec fica del cable de control AC por favor consulte el manual de operaci n o de propietario de los sistemas de aire acondicionado AP NDICE D M DULOS DE ADMINIS TRACI N DE CARGA DIGITAL DIGITAL LOAD MANAGMENT DLM El controlador de carga puede operar hasta cuatro DLMs separados cada uno conectado de la misma forma que abajo e La caja del m dulo DLM se puede instalar en interiores o exteriores Si la caja se monta en exteriores se DEBE orientar con el agujero de drenaje en la parte de abajo e El m dulo DLM est acondicionado con ubicaciones del dispositivo de eliminaci n del conducto
103. les T1 y T2 para asegurarse que la corriente fluya en forma apropiada a trav s del contactor 4 Complete el cableado al interruptor de transferencia conectando los cables de tierra del equipo del servicio p blico y el generador a la leng eta de tierra 5 Teniendo cuidado de sostener las leng etas aplique torque a las leng etas en el interruptor de transferencia a las especificaciones en el interruptor de transferencia Calcoman a ubicada dentro de la puerta del interruptor 52 4 Apague el interruptor de circuito principal del generador y ponga el interruptor de modo en la posici n OFF apagado 9 Apague el interruptor de circuito principal del generador y ponga el interruptor de modo en la posici n OFF apagado 5 Aseg rese que la energ a p blica est apagada y coloque todos para apagar el generador los interruptores de circuito individual en el panel principal de distribuci n en la posici n OFF apagado 10 Con el servicio p blico aun apagado use el manubrio de transferencia para mover los contactos principales a la posici n ARRIBA servicio p blico 6 Ubique el manubrio de transferencia inserte el extremo metal en la ranura en la unidad de contactor principal Tire el manubrio ABAJO para mover los contactos principales a la posici n de energ a de respaldo generador NUNCA OPERE EL INTERRUPTOR DE TRANSFERENCIA MANUALMENTE CUANDO LAS CARGAS EST N CONECTADAS 7
104. lt 2 18 SC STARTER CONTACTOR Su SCR STARTER CONTROL RELAY SM STARTER MOTOR SP SPARK PLUG 27 Electrical Data Wiring Diagram Schematic 17kW Drawing No 0H6198 A ENGINE panasaran d a L 2 N2B DIL WARMER lt OPTIONAL CONNECT TIA arta AA 27 2 N1A DE SEARING o BEARING 44 BA DE 4 11 i rJ ____ 44 2 6 Hot HET 4 T1 N2 44 0 x 00 2 11 4 112 314 1516171 81 9110 1112 1314 GOVERNOR Z lt CONTROLLER FIELD BOOST DIODE 1121314 1516171 8 910 1121314 15 16 17 118 19 20 21 22 23 90 13 818 85 14 86 56 194 Ji 1817 1819 820 210 18 209 23 85 86 O St HA FRAME O GND 0 20 6 6 CONTROL PANEL 22 33 44 if 00 Ly 194 209 210 820 818 819 0 0 Wiring Diagram Schematic 17kW Drawing No 0H6198 A Electrical Data 200000 TRANS SIG e 2 gt qc O 0 0000 240 OUTPUT TO TRANSFER SWITCH CONTACTOR CB1 E j por IL LEAL T CUSTOMER CONNECT AREA 11C 14 11C 14 00 120V 15A DUPLEX LEGEND BA BRUSH ASSEMBLY CB1 CIRCUIT BREAKER MAIN OUTPUT CB2 CIRCUIT BREAKER GFCI GND GR
105. mW ME am mum Ae ims 1114 mM See 8 Brancher maintenant les fils d alimentation rouge et noir au disjoncteur tant donn qu il s agit d une application monophas e cela n a pas d importance quel fil est branch a quelle cosse 9 Brancher le conducteur de terre vert de l quipement la barre omnibus de mise la terre et le couple 35 pouces livres Les valeurs du couple sont les suivantes e 10 14 AWG 35 pouces livres 40 pouces livres e 4 6 AWG 45 pouces livres 69 BE 87 a DEn o e 10 Brancher le fil neutre blanc la barre omnibus neutre et serrer au couple de 35 pouces livres Les valeurs du couple sont les suivantes e 10 14 AWG 35 pouces livres 8 AWG 40 pouces livres e 4 6 AWG 45 pouces livres 11 Brancher les fils de commande aux bonnes bornes Les bornes sont clairement marqu es 1 N2 23 194 et T1 Si un commutateur est connect un c ble 0 z ro sera galement n cessaire REMARQUE Afin de maintenir la s paration des circuits les fils de commande CC doivent tre s par s des fils de commande AC Pour ce faire une gaine en fibre de verre a t fournie dans le kit manuel Faire glisser la gaine sur les fils CA OU les fils CC mais pas sur les deux de la zone d arriv e des fils l ext rieur du g n rateur Utiliser les emplacements des colliers des fils pour maintenir la gaine en place
106. maintain separation of circuits the DC control wires must be separated from the AC control wires A piece of fiberglass sleeving has been provided in the manual kit to achieve this Slide the sleeving over the AC wires OR the DC wires but not both from the wire landing area to the outside of the generator Use the cable tie locations to hold the sleeving in place 12 An improperly connected control wire can damage the generator control board APPENDIX A EZ SWITCH INSTALLATION amp TESTING 1 Before beginning any installation make sure power is shut OFF to the main distribution panel and carefully read the Owner s Manual that came with the transfer switch The distributed load center switch must be mounted close enough to the main distribution panel to accommodate the two foot pre wired Make sure no water or corrosive substances can drip onto the transfer switch enclosure SU ay 3 D ay M hy F ud s i A A n e ia xi s s um 29 up a T i a O L n af d S z E t E TE TE T a a ET 2 Always inspect the switch for ve mount a transfer switch that shows any evidence of damage 3 Protect against impact and mount the switch vertically to a rigid support structure Make sure the switch is level and plumb The transfer switch is an open transition switch Open transition switches pr
107. mation d arc et en fonctionnant afin de mettre hors tension le circuit en cas de d faut d arc 2 Pieces habitables tous les circuits de d rivation qui alimentent les prises de 125 volts monophas es de 15 et 20 amperes install es dans les pi ces habitables doivent tre prot g s par un interrupteur de circuit de d faut d arc indiqu pour fournir une protection a tout le circuit de d rivation La section 210 12 exige que la protection d interruption de circuit de d faut d arc AFCI soit assur e sur les circuits de d rivation qui alimentent les prises prise clairage etc dans les pi ces habitables l exigence se limite aux circuits de 15 et 20 amp res 125 volts Il n y a aucune interdiction de fournir une protection AFCI sur les autres circuits ou dans d autres endroits que les pi ces Etant donn que les circuits sont souvent partag s entre une pi ce et d autres endroits tels que les toilettes et les couloirs le fait de fournir une protection AFCI sur tout le circuit serait conforme la section 210 12 si pendant l installation du syst me de secours usage domestique il a t d cid de fournir une alimentation de secours un circuit de d rivation de pi ce il faut remplacer le disjoncteur du commutateur de transfert par un interrupteur de circuit de d faut d arc Le plus important est que les disjoncteurs soient uniquement commut s de mani re identique Par exemple en cas de remplacement d
108. me tous les codes toutes les normes et r glementations Se reporter au Manuel d entretien du commutateur de transfert et au National Electrical Code Code lectrique national pour obtenir des informations suppl mentaires j a h y i Wi uc aero 2 Comme dans tout produit des modifications de la conception peuvent survenir au fil du temps Se reporter toujours aux sch mas du Manuel d entretien du commutateur de transfert pour conna tre les branchements n cessaires et les pr cautions de s curit Open Transition Switch Prevents Electrical Feedback Load Circuits Isolated to Single Power Supply 6 Le commutateur de transfert utilis est un commutateur coupure Le commutateur a coupure emp che la r troaction divergente lectrique entre le g n rateur et le r seau public en permettant seulement aux circuits de charge d tre connect s a une seule alimentation a la fois COUVERTURE DU CIRCUIT SELECTIONNE 2 commutateur de transfert de la m me intensit que le r seau public est install entre le r seau public et le panneau de distribution principal Ce commutateur de transfert devient le r seau public ainsi aucun sectionneur n est n cessaire Le panneau de distribution principal existant devient un panneau secondaire 1 Le g n rateur alimente uniquement les circuits d sign s qui sont r unis et c bl s sur un panneau de di
109. mente y no tiene la intenci n de cubrir todas las aplicaciones Si persisten dudas luego de leer cuidadosamente toda la documentaci n recibida con el equipo contacte al concesionario m s cercano y pida ayuda 97 Parte No 0H8536 Revisi n E 06 23 10 Catalog No IM ASPEA 01 Impreso los EE UU 58 CONSIGNES D INSTALLATION G n rateurs refroidis TABLE DES MATIERES PP a 60 Lire attentivement Ce 60 Contenu 61 Fonctionnement et maintenance 61 Comment obtenir l entretien 61 De dies do SCHO 61 index des MOMO 62 D ballage inspection 63 Exigence du NEC en mati re de disjoncteur d interruption de circuit de d faut d arc pour les pi ces habitables 63 Protection de l interrupteur de circuit de d faut d arc de la section 210 12 PP 63 Avant de commencer 64 Pr paration du site et mise en place du g n rateur 64 Transformation en vapeur de 65 Installation et raccordement des canalisations de gaz 66 Branchements lectriques externes 67 Activation du g n rateur 67 oe 88 Branchements du g
110. n rateur Commutateur EZ 99 Annexe Installation et test op rationnel du commutateur EZ 70 Installation de la 72 12 Annexe B Installation et test op rationnel du commutateur de Wanstert RISA GCR ToU sostener u u naei 74 Couverture du circuit s lectionn 75 Couverture du circuit multipi Ce_ 15 Branchements lectriques 15 A Ll 76 Annexe C Gestion num rique de la charge DLM 78 Annexe D Modules de gestion num rique de la charge DLM 79 E D finition de la fonction de programme de test A 80 a ee 81 60 INTRODUCTION Nous vous remercions d avoir achet ce g n rateur entra n par moteur compact haute performance refroidi l air Il est con u pour fournir l alimentation lectrique afin de faire fonctionner les charges critiques pendant une coupure de courant Cette unit est install e en usine dans une enveloppe en m tal imperm able qui est exclusivement con ue pour une installation l ext rieur Ce g n rateur fonctionnera l aide de propane liquide PL ou de gaz naturel GN retir vapeur REMARQUE Ce g n rateur est appropri pour l alimentation
111. nabled until an overload is detected e When an overload is detected all loads are disabled e After 5 minutes priority 1 loads are enabled e After another 30 seconds priority 2 loads are enabled e After another 30 seconds priority 3 loads are enabled e After another 30 seconds priority 4 loads are enabled If an overload is detected within 30 seconds of a level being enabled all loads are disabled again and the sequence repeats However the level that caused the overload and all levels higher will not be enabled again for 30 minutes Control of Air Conditioner Load 1 Route the thermostat cable from the furnace thermostat to the outdoor air conditioner unit to the transfer switch 2 Connect the wire to the terminal strip terminals Air 1 on the LSM as shown in Figure 2 2 These are normally closed contacts which open upon load shed conditions Route thermostat wire away from High voltage wires 3 lf required connect the second air conditioner to the terminal Strip terminals Air 2 Contact Ratings Air 1 amp 2 24 VAC 5 0 Amps Max NOTE These instructions are for a typical air conditioner installation Control of heat pump and 2 stage air conditioners will require special connections Load Shed Module Connections ED ED 0 Ground 194 12V 23 Transfer CONTACTOR R 1 D 2 o an Coil wires CONTACTOR an li 3 an Supply CONTACTOR Contactor 1 Load 1
112. nerator unsafe A DANGER Despite the safe design of this generator operating this equipment imprudently neglect ing its maintenance or being careless can cause possible injury or death Permit only responsi ble and capable persons to install operate and maintain this equipment Potentially lethal voltages are generated by these machines Ensure all steps are taken to render the machine safe before attempting to work on the generator Parts of the generator are rotating and or hot during operation Exercise care near running generators Installation must always comply with applicable codes standards laws and regulations A running generator gives off carbon monoxide and odorless colorless poison gas Breathing in carbon monoxide can cause headaches fatigue diziness nausea vomitting confusion fainting siezures or death CALIFORNIA PROPOSITION 65 WARNING Engine exhaust and some of its constituents are known to the State of California to cause cancer birth defects and other reproductive harm CALIFORNIA PROPOSITION 65 WARNING This product contains or emits chemicals known to the otate of California to cause cancer birth defects and other reproductive harm GENERAL HAZARDS For safety reasons the manufacturer recommends that this equipment be installed serviced and repaired by a Service Dealer or other competent qualified electrician or installation technician who is familiar with applicable codes
113. nit subisse le programme de test 8 Sile g n rateur est quip d une fonction de programme de test basse vitesse elle a t activ e l usine et ne n cessite aucun r glage Chaque installation dispose de son propre ensemble de circonstances et d exigences Ce manuel donne des consignes pour les installations de base uniquement et n est pas cens traiter toutes les applications Si vous avez des questions ou inqui tudes apr s voir lu attentivement toute la documentation recue avec l quipement contacter le d positaire le plus proche pour obtenir de l aide Remarques 81 R f rence 098538 R vision E 23 06 10 Catalog No IM ASPEA 01 Imprim aux Etats Unis
114. om the top the roof may appear stuck Always verify that the side lock is unlocked before attempting to lift the roof NEC REQUIREMENT FOR ARC FAULT CIRCUIT INTERRUPTION BREAKER FOR BEDROOMS In 2001 the National Electric Code NEC introduced a requirement for new construction This new requirement indicates the need for Arc Fault Circuit Interrupters to be used to protect the complete branch circuit that feeds a dwelling bedroom The actual NEC requirement is indicated below SECTION 210 12 ARC FAULT CIRCUIT INTERRUPTER PROTECTION 1 Definition An arc fault circuit interrupter is a device intended to provide protection from the effects of arc faults by recognizing characteristics unique to arcing and by functioning to de energize the circuit when an arc fault is detected 2 Dwelling Unit Bedrooms All branch circuits that supply 125 volt single phase 15 and 20 ampere outlets installed in dwelling unit bedrooms shall be protected by an arc fault circuit interrupter listed to provide protection of the entire branch circuit Section 210 12 requires that protection be provided on branch circuits that supply outlets receptacle lighting etc in dwelling bedrooms The requirement is limited to 15 and 20 ampere 125 volt circuits There is no prohibition against providing AFCI protection on other circuits or in locations other than bedrooms Because circuits are often shared between a bedroom and other areas such as closets and h
115. ons de fonctionnement dangereuses suite une fuite gaz d chappement une fuite de carburant une fuite d huile etc DANGERS LECTRIQUES Tous les g n rateurs trait s par ce manuel produisent des tensions lectriques dangereuses et peuvent entrainer une lectrocution mortelle Le r seau lectrique d livre des tensions extr mement lev es et dangereuses au commutateur de transfert comme le g n rateur de secours pendant son fonctionnement Eviter le contact avec les fils nus les bornes les branchements etc pendant le fonctionnement de l unit S assurer que tous les couvercles les dispositifs de protection et les barri res sont en place s curis s et ou verrouill s avant de faire fonctionner le g n rateur Si un travail doit tre effectu autour d une unit en fonctionnement rester sur une surface isol e et s che pour r duire le risque de danger lectrique Ne jamais manipuler tout type de dispositif lectrique qui est dans l eau alors que vous tes pieds nus ou que vos mains ou vos pieds sont mouill s CELA ENTRAINERA UN RISQUE D ELECTROCUTION Le National Electric Code NEC Code lectrique national exige que le b ti et que les pieces externes lectriquement conductrices du g n rateur soient correctement reli s une terre approuv e Les codes lectriques locaux peuvent galement exiger la bonne mise la terre du syst me lectrique du g n rateur Apr s avoir install ce
116. outes les charges sont d sactiv es nouveau et la s quence recommence Toutefois le niveau qui a caus la surcharge et tous les niveaux sup rieurs ne seront pas activ s nouveau pendant 30 minutes Contr le de la charge de climatisation 1 Faire passer le c ble du thermostat partir du four thermostat l unit de conditionnement de l air ext rieur vers le commutateur de transfert Relier le fil aux bandes de borne du bornier Air 1 sur le LSM comme le montre la Figure 2 2 Ce sont des contacts normalement ferm s qui s ouvrent sur des conditions de d lestage Faire passer le fil du thermostat loin des c bles de haute tension 3 Si n cessaire brancher le deuxi me climatiseur aux bandes de borne du bornier Air 2 Valeurs nominales de contact Air 1 et 2 24 VCA 5 A max Connexions du module de d lestage 0 Terre 194 12V 23 Transfert CONTACTEUR CONTACTEUR B Aimentaion Contacteur vate 25 n 1 n 1 Alimentation ep CONTACTEUR ES pee Charge s ES Fils de bobine V LZ E Alimentation Contacteur Charge n 3 n 3 Alimentation Contacteur Charge n 4 n 4 79 REMARQUE Ces instructions sont pour une installation de climatiseur classique Le contr le de la pompe a chaleur et des clima tiseurs biphas s n cessitera des raccordements sp ciaux Controle d un contacteur s par Un module de relais de cont
117. r leur ait d j interrompu certaines charges Appuyer sur le bouton TEST du contr leur de charge Cette fonction d connectera toutes les charges contr l es par le contr leur Le contr leur de charge reconnectera ensuite chaque charge d une mani re programm e et d cal e telle que d crite dans le Manuel d entretien du commutateur de transfert TESTS FONCTIONNELS ET R GLAGES Apres l installation et l interconnexion du commutateur de transfert inspecter attentivement toute l installation Un lectricien comp tent et qualifi doit l inspecter L installation doit tre strictement conforme tous les codes normes et r glementations applicables Lorsque l on est absolument s r que l installation est appropri e et correcte effectuer un test fonctionnel du systeme 80 Hot Water Heater NT N2_ gi e 0 DLM P
118. r assistance 21 Electrical Data Wiring Diagram Schematic 8kW Drawing No 0H6912 A ENGINE COMPARTMENT CONTROL PANEL fo n 2 4 2 lt OIL WARMER EE 1 T 240Vac OPTIONAL _ 11 BEARING 44 44 00 251 4 T N 6 1 00 2 11 4 SCR lt 11213141516 71 8 9 10 11 12 13 14 x N2A FIELD BOOST DIODE 1121314 1516171 8 9 10 11112113 14115116 17 18 19 20 21122123 90 13 818 85 14 86 56 194 J1 817 819 820 210 18 209 23 0 SAE A 171117111 209 E SRE 820 817 Bc 0 0o q o 15 ENGINE 0 GND 6 FRAME GND i 22 Wiring Diagram Schematic 8kW Drawing No 0H6912 A Electrical Data CUSTOMER CONNECT AREA 240V GENERATOR OUTPUT TO TRANSFER SWITCH CONTACTOR CB1 T TRANS SIG 1 LLL DLL N2A LEGEND BRUSH ASSEMBLY N2A CIRCUIT BREAKER MAIN OUTPUT GND GROUND T L1 GREEN SYSTEM READY HTO HIGH TEMPERATURE SWITCH ___194 ________ L2 YELLOW MAINTENANCE REQ D IM IGNITON MODULE L3 RED ALARM LOP LOW OIL PRESSURE SWITCH 510 LED BOARD SC STARTER CONTACTOR 820 SM STARTER MOTOR s SP SPARK PLUG Ime 2 819
119. r se enfr e antes de apagarse solo Apague la energ a p blica nuevamente El generador deber arrancar y la carga de prioridad entera deber transferirse al generador Cierre el interruptor principal para restaurar la energ a p blica y deje que el motor enfr e y se apague 15 Las pruebas de operaci n est n ahora completas Consulte Configurando la funci n de ejercicio autom tico para completar la instalaci n APENDICE INTERRUPTOR DE TRANS FERENCIA RTSX Y RTSD PRUEBA DE INSTA LACION Y OPERACION o 1 Mesi EE A 1 Antes de emprezar cualquier instalaci n aseg rese que la energ a est apagada al panel de distribuci n principal y lea cuidadosamente el manual del propietario que vino con el interruptor de transferencia Para simplificar el proceso de instalaci n el interruptor de transferencia deber montarse lo m s cerca posible del panel de distribuci n principal Aseg rese de que no gotee agua ni sustancias corrosivas en la caja del interruptor de transferencia 2 Siempre inspeccione el interruptor si tiene da os por el embarque Nunca monte un interruptor de transferencia que 0 muestre alguna evidencia de da o Prot jalo contra impactos y monte el interruptor verticalmente a una estructura de soporte r gida Aseg rese de que el interruptor est nivelado y a plomo Revise los c digos locales antes de cabl
120. rawing No 0H7358 A Electrical Data ENGINE 2222585 1 FL CONTROL PANEL m 2 OIL WARMER 1 lt N1B OPTIONAL CONNECT por N2A 22 33 44 11 de ____ HI o GOVERNOR 7 ae N2A IM2 T FIELD BOOST i doll 10kW 357R 14kW 768R 209 210 56 56 817 m ad 1 os Lg Q _H NN 0o n gt BED 0 4 ENGINE o GND PROME 6 GND a 29 Electrical Data Wiring Diagram Schematic 10 14kW Drawing No 0H7358 A 240V GENERATOR OUTPUT TO TRANSFER SWITCH CONTACTOR 0 O 0 22 a PH a EN RH p Top _ 5 1 _ _ LL 2 2 j L1 GREEN SYSTEM READY L2 YELLOW MAINTENANCE REQ D L3 RED ALARM 209 210 LED BOARD 820 nn pt ___ MA gt 1 0 2 gt 240Vac CONNECT BLACK O BATTERY 26 CUSTOMER CONNECT AREA LEGEND BA BRUSH ASSEMBLY CB1 CIRCUIT BREAKER MAIN OUTPUT GND GROUND HIGH TEMPERATURE SWITCH IM_ IGNITON MODULE LOW OIL PRESSURE SWITCH MOV VARISTOR SC
121. re el interruptor principal para restaurar la energ a p blica y aseg rese de que el voltaje p blico en el interruptor de transferencia sea el correcto Consulte al NFPA 70 E por el equipo de seguridad requerido al trabajar dentro del interruptor de transferencia vivo ID l 13 Antes de comprar una bater a para el generador consulte en el manual del propietario una lista de bater as recomendadas Siga todos los procedimientos y precauciones de seguridad en el manual del propietario al instalar la bater a INSTALACI N DE LA BATER A 1 Antes de comprar una bater a para el generador consulte el manual del propietario la bater a recomendada 8 kW Grupo 26R 12 Volt 350cca minimo e 10 20 kW Grupo 26R 12 Volt 525cca minimo 2 Siga todos los procedimientos y precauciones de seguridad en el manual del propietario del generador al instalar la bater a Verifique que el interruptor est en la posici n de apagado Al preparar la prueba de operaci n NO conecte la bater a hasta que las conexiones del interruptor de transferencia est n completas 48 PRUEBAS DE OPERACI N 2 Aseg rese que la energ a p blica est apagada y coloque todos los interruptores de circuito de prioridad en el interruptor de transferencia en la posici n OFF apagado 3 Ubique el manubrio de transferencia inserte el extremo de metal en la ranura en la unidad conectora principal y tire el manubrio hacia ABAJO para
122. rte de 5 precableado y conectado al generador no se necesita conexiones adicionales en el generador S ltese la secci n siguiente y proceda con el ap ndice A Instalaci n del interruptor EZ y pruebas de operaci n 2 Si el interruptor EZ fue adquirido en forma separada del generador se necesitar un l tigo de sellado duro de 5 para conectarse al generador Para completar el cableado corra un conducto 3 4 para las puntas de energ a y cables de control desde la caja de conexi n el ctrica al generador 3 Retire los dos tornillos que aseguran la cubierta del rea de conexi n y retire la cubierta 4 Paselos cables a trav s de la parte de atr s del generador y asegure el conducto con una tuerca de cierre 5 Pase las puntas de energ a a traves del liberador de tensi n proporcionado 6 El interruptor de circuito est adjunto al panel de acceso exterior 7 Retire los conectores pl sticos dentro del rea de acceso al interruptor principal para permitir la conexi n de las puntas de energ a al interruptor de circuito wa LI LI ac AMO MEM A TANUM Ti 8 Ahora conecte las puntas de energ a roja y negra al interruptor de circuito En vista de que esta es una aplicaci n monof sica no importa qu cable se conecta a qu oreja 9 Conecte el cable de tierra verde del equipamiento con la barra del bus de t
123. stribution prioritaire s par Le commutateur de transfert est install entre le panneau de distribution principal et le panneau prioritaire l intensit nominale du commutateur de transfert doit tre gale ou sup rieure l intensit nominale la plus lev e du r seau public et des disjoncteurs du g n rateur alimentant le commutateur COUVERTURE DU CIRCUIT MULTIPIECE 3 La mise la terre qui est normalement situ e sur le panneau principal sera r alis e sur le commutateur de la m me intensit que le r seau public et doit tre d connect e du panneau de distribution existant Se reporter au National Electrical Code NEC pour obtenir des informations compl tes sur la mise la terre et la connexion BRANCHEMENTS LECTRIQUES 1 Le g n rateur soutiendra toutes les charges lectriques du panneau Par cons quent l intensit nominale du commutateur de transfert doit tre gale ou sup rieure l intensit nominale normale du r seau public Un sectionneur du r seau public doit tre plac avant le commutateur de transfert sauf si un commutateur de transfert de la m me intensit que le r seau public est utilis Le commutateur de transfert doit tre install entre le branchement du r seau public et le panneau de distribution du b timent 1 Brancher les fils d alimentation du g n rateur et du r seau public aux cosses appropri es du commutateur de transfert Les cosses sont clairement marq
124. syst me lectrique de secours usage domestique le g n rateur peut tourner et d marrer tout moment sans avertissement Lorsque cela se produit les circuits de charge sont transf r s vers la source d alimentation de SECOURS 62 g n rateur Afin d viter des blessures ventuelles si de tels d marrage et transfert se produisent toujours r gler l interrupteur AUTO OFF MANUAL Auto arr t manuel sur la position OFF Arr t avant de travailler sur l quipement et retirer le fusible de 15 A du panneau de commande du g n rateur En cas d accident caus par lectrocution couper imm diatement la source d alimentation lectrique Si cela est impossible essayer de lib rer la victime du conducteur sous tension EVITER TOUT CONTACT DIRECT AVEC LA VICTIME Utiliser un objet non conducteur comme une corde ou une planche s che pour lib rer la victime du conducteur sous tension Si la victime est inconsciente assurer les premiers secours et demander une aide m dicale imm diate Ne jamais porter de bijoux lors du travail sur cet quipement Les bijoux peuvent tre conducteurs et entrainer une lectrocution ou peuvent s accrocher sur les composants mobiles entrainant des blessures RISQUES D INCENDIE Pour la s curit contre les incendies le g n rateur doit tre correctement install et entretenu L installation doit toujours respecter les codes normes lois et r glementations applicables otrictement resp
125. t de perte ou de dommage du consignateur Si une perte ou un dommage est observ e apr s la livraison mettre les mat riaux endommag s part et contacter le transporteur pour entamer des proc dures de r clamation l expression avarie non apparente est comprise comme d signant un dommage au contenu d un colis qui n est pas visible lors de la livraison mais est d couvert plus tard Afin d ouvrir correctement le toit appuyer sur la l vre sup rieure centrale et rel cher le loquet Si la pression n est pas appliqu e du dessus le toit peut sembler bloqu Toujours v rifier si le loquet lat ral est d verrouill avant d essayer de soulever le toit EXIGENCE DU NEC EN MATIERE DE DISJONCTEUR D INTERRUPTION DE CIRCUIT DE DEFAUT D ARC POUR LES PIECES HABITABLES En 2001 le National Electric Code NEC Code lectrique national a introduit une exigence relative la nouvelle construction Cette nouvelle exigence indique la n cessit que les interrupteurs de circuit de d faut d arc soient utilis s afin de prot ger tout le circuit de d rivation qui alimente une piece habitable NEC actuelle est indiqu e ci dessous PROTECTION DE LINTERRUPTEUR DE CIRCUIT DE DEFAUT D ARC DE LA SECTION 210 12 1 D finition un interrupteur de circuit de d faut d arc est un dispositif concu pour fournir une protection contre les effets des d faillances d arc en reconnaissant les caract ristiques uniques de la for
126. tema de combustible deben purgarse apropiadamente y buscar fugas de acuerdo al c digo aplicable Luego de la instalaci n inspeccione el sistema de combustible periodicamente en busca de fugas No se permiten fugas NDICE DE EST NDARES En ausencia de los est ndares c digos regulaciones o leyes pertinentes la informaci n publicada listada abajo puede usarse como gu a para la instalaci n de este equipo 1 No 37 STATIONARY COMBUSTION ENGINES AND GAS TURBINES disponible en la National Fire Protection Association 470 Atlantic Avenue Boston MA 02210 2 NFPA No 76A ESSENTIAL ELECTRICAL SYSTEMS FOR HEALTH CARE FACILITIES disponible igual que el Item 1 No 54 NATIONAL FUEL GAS CODE disponible igual que el 1 4 No 58 AMERICAN NATIONAL STANDARD FOR STORAGE AND HANDLING OF LIQUEFIED PETROLEUM GAS disponible igual que el Item 1 5 No 70 NFPA HANDBOOK OF NATIONAL ELECTRIC CODE disponible igual que el 1 6 Art culo X NATIONAL BUILDING CODE disponible en la American Insurance Association 85 John Street New York N Y 10038 7 AGRICULTURAL WIRING disponible en la Food and Energy Council 909 University Avenue Columbia MO 65201 8 ASAE EP 3634 INSTALLATION AND MAINTENANCE OF FARM STANDBY ELECTRICAL SYSTEMS disponible en la American Society of Agricultural Engineers 2950 Niles Road St Joseph MI 49085 9 NFPA No 30 FLAMMABLE AND C
127. tenimiento para una segura operaci n y hacer revisar peri dicamente el equipo por un concesionario El normal mantenimiento y reemplazo de piezas son de responsabilidad del propietario operador y como tal no se considera defectos de material ni mano de obra dentro de los t rminos de la garant a Los h bitos individuales de operaci n y uso contribuyen a la necesidad de servicio de mantenimiento Un mantenimiento apropiado y el cuidado del generrador aseguran un n mero m nimo de problemas y mantienen los gastos operativos al m nimo Consulte a su concesionario para que lo ayude en el servicio y con los accesorios C MO OBTENER SERVICIO Cuando el generador requiere servicio o repuestos busque ayuda con el concesionario Los t cnicos de servicio est n capacitados en f brica y son capaces de manejar todas las necesidades de servicio Al ponerse en contacto con un concesionario respecto a repuestos y servicio siempre proporcione el n mero de modelo y de serie de la unidad tal como est en la calcoman a de datos ubicada en el generador Vea la ubicaci n de la calcoman a en la secci n de El Generador Modelo No Serie No REGLAS DE SEGURIDAD Guarde estas instrucciones El fabricante sug iere que estas reglas para la operaci n segura se copien y publiquen cerca del sitio de insta laci n de la unidad Debe insistirse en la segu ridad para todos los operadores y potenciales operadores de este equipo Estudie
128. the generator requires servicing or repairs contact a Dealer for assistance Service technicians are factory trained and are capable of handling all service needs When contacting a Dealer about parts and service always supply the complete model number and serial number of the unit as given on its data decal which is located on the generator See section The Generator for decal location Model No Serial No SAFETY RULES Save These Instructions The manufacturer suggests that these rules for safe operation be copied and posted near the unit s installation site Safety should be stressed to all operators and potential operators of this equipment otudy these SAFETY RULES carefully before installing operating or servicing this equipment Become familiar with this Owner s Manual and with the unit The generator can operate safely efficiently and reliably only if it is properly installed operated and maintained Many accidents are caused by failing to follow simple and fundamental rules or precautions The manufacturer cannot anticipate every possible circumstance that might involve a hazard The warnings in this manual and on tags and decals affixed to the unit are therefore not all inclusive If using a procedure work method or operating technique the manufacturer does not specifically recommend ensure that it is safe for others Also make sure the procedure work method or operating technique utilized does not render the ge
129. tienen el generador a la paleta de madera A Ma S 4 Aseg rese de que el equipo de elevaci n a usarse tenga la suficiente capacidad para manejar en forma segura el peso del generador Use cuerdas de elevaci n de nylon y con ctelas a los ojales de elevaci n en cada esquina del marco de la base para evitar dafios en la caja 5 Coloque el generador en la almohadilla para que la cama de gravilla se extienda algunas pulgadas m s all del generador en todos los lados Aseg rese de que el generador est nivelado dentro de la 1 2 pulgada Conecte una correa de tierra aprobada a la oreja de tierra en el marco de base y a una tierra aprobada o varilla de tierra como lo especifican las regulaciones locales Revise el aceite de motor y si es necesario agregue lo suficiente del aceite recomendado para llevar el nivel a la marca de FULL en la varilla Tenga cuidado de no sobrecargar el c rter El generador fue configurado para operaci n con gas natural en la f brica El cambio a GLP es un procedimiento simple En los modelos con un motor de cilindro nico empiece desconectando y retirando la bater a si est instalada Tome el manubrio en T de pl stico del selector de combustible en la bolsa suministrada con el generador y ubique la pesta a selectora en la cubierta de la caja de aire Inserte el extremo del pasador en el agujero de la pesta a selectora y tire hacia afuera para vencer la presi n del resorte Lu
130. to para una nueva construcci n Este nuevo requerimiento indica la necesidad de usar interruptores de circuito de falla de arco para proteger la rama completa del circuito que alimenta el dormitorio de una vivienda El requerimiento del NEC se indica abajo SECCI N 210 12 PROTECCI N POR INTERRUPTOR DE CIRCUITO CONTRA FALLAS DE ARCO 1 Definici n Un interruptor de circuito para falla de arco es un dispositivo cuyo prop sito es proporcionar protecci n de los efectos de fallas de arco reconociendo las caracter sticas nicas del arco y procediendo a desenergizar el circuito cuando se detecta una falla de arco 2 Dormitorios de viviendas Todos los circuitos ramales que suministran 125 voltios con salidas de 12 y 20 amperios monof sicos instaladas en dormitorios de viviendas ser n protegidas por un interruptor de circuito de falla de arco listado para proporcionar protecci n al ramal competo del circuito La Secci n 210 12 requiere que se proporcione protecci n AFCI los circuitos ramales que suministran salidas recept culos iluminaci n etc en dormitorios de viviendas El requerimiento se limita a circuitos de 15 y 20 amperios de 125 voltios No hay prohibicion contra proporcionar protecci n en otros circuitos o en ubicaciones diferentes a los dormitorios Debido a que los circuitos frecuentemente se comparten entre un dormitorio y otras reas como armarios y pasillos el proporcionar protecci n sobre el
131. tor is level within Y inch e 2 Take the plastic T handle fuel selector in the poly bag supplied with the generator and locate the selector tab on the air box cover Insert the pin end into the hole in the selector tab and pull outward to overcome spring pressure Then twist clockwise 90 degrees and allow the selector to return in once aligned with the LP position gt SS Fuel Selection Lever In 6 Connect an approved ground strap to the grounding lug on the Position for base frame and to an approved earth ground or grounding rod a a as specified by local regulations 5 um 7 Check the engine oil and if necessary add enough of the recommended oil to bring the level up to the FULL mark the dipstick Be careful not to overfill the crankcase Y gs 259 lt a Em 8 3 On 10 kW units open the roof loosen the forward clamp on the air inlet hose and slide the hose away from the hose Position for Liquid Propane Vapor Fuel 4 Slide the fuel selector pin on the carburetor out towards the back of the enclosure 9 Replace the inlet hose and tighten the clamp securely hu Fuel Selection Lever Out Position for Liquid Propane Vapor Fuel 1 The generator was configured for natural gas operation at the factory Switching over to LP Vapor is a simple procedure On models with a single cylinder engine begin by disconnecting
132. u es sur le commutateur N alimentation du r seau public normale E panneau de connexion du g n rateur T panneau de distribution 19 TEST OPERATIONNEL 2 Les fils neutres du r seau public et du g n rateur sont connect s 1 Si le commutateur RTSD va tre install le r seau public a t modifi la m me cosse neutre du commutateur faut donc s assurer que les raccordements sont corrects avant de remettre sous tension le r seau public 3 Brancher les fils de commande du g n rateur au bloc de jonction du commutateur de transfert Les bornes sont marqu es N1 23 11 2 Placer le disjoncteur principal sur la position OFF Arr t Se reporter et 194 ou 15B la norme NFPA 70 E pour conna tre l quipement de s curit n cessaire lors d un travail l int rieur d un commutateur de transfert 4 Terminer le c blage du commutateur de transfert en branchant les fils de mise la terre de l quipement du r seau public et du g n rateur la cosse de mise la terre 3 Mettre sous tension le r seau public et v rifier la tension phase phase et la tension de phase nominale au niveau des bornes N1 et N2 du contacteur de transfert Si la tension phase phase n est pas d environ 240 volts mettre hors tension l alimentation du r seau public et v rifier les raccordements entre le r seau public et les bornes N1 et N2 Si la tension de phase nominale n est pas d environ 120 volts m
133. u de distribution un par un jusqu a ce que le g n rateur accepte la charge complete 16 Le g n rateur portant la charge complete recontr ler la pression du gaz pour v rifier qu elle se trouve au niveau auquel elle se situait avant le d marrage du g n rateur REMARQUE M me si le g n rateur fonctionne correctement ce stade une baisse de la pression du gaz indique que l alimentation convient peine pour r pondre aux besoins du g n rateur Des modifications de la charge du g n rateur ou une demande de gaz suppl mentaire par d autres appareils peut affecter les performances du g n rateur V rifier la pression du gaz et la dimension des tuyaux D crocher le manometre et r installer la prise m le 78 17 Placer le disjoncteur r seau public sur la position ON Marche pour r tablir l alimentation du r seau public 18 Le g n rateur continuera de fonctionner pour permettre au moteur de se refroidir puis s arr tera automatiquement 19 Remettre l alimentation du r seau public hors tension Le g n rateur doit d marrer et la charge prioritaire complete doit tre transf r e vers le g n rateur 20 Fermer Agence pour r tablir l alimentation du r seau public et laisser le moteur se refroidir et s arr ter automatiquement Les tests op rationnels sont d sormais termin s Se reporter l Annexe E D finition de la fonction de programme de test automatique ANNEXE C
134. un disjoncteur de 15 A il DOIT tre remplac par un disjoncteur AFCI de 15 A De m me un disjoncteur de 20 A DOIT tre remplac par un disjoncteur AFCI de 20 A Ces disjoncteurs AFCI sont disponibles au magasin de mat riel le plus proche Code d article Siemens Description Q115AF AFCI unipolaire 15A Q120AF AFCI unipolaire 20A 63 AVANT DE COMMENCER Contacter l inspecteur local ou la mairie pour conna tre tous les codes f d raux d Etat et locaux qui pourraient concerner l installation Obtenir toutes les autorisations n cessaires avant de commencer le travail Lire et suivre attentivement toutes les proc dures et pr cautions de s curit d taill es dans le guide d installation Si toute partie du manuel d installation du manuel technique ou d autres documents fournis par l usine n est pas enti rement comprise contacter un d positaire pour obtenir de l aide Se conformer enti rement toutes les normes NEC NFPA et OSHA applicables ainsi qu tous les codes de construction et lectriques f d raux d Etat et locaux Comme avec tout g n rateur il faut installer cette unit conform ment aux normes NFPA 37 et NFPA 70 actuelles ainsi qu tout autre code f d ral d Etat et local pour les distances minimales avec les autres structures PREPARATION DU SITE ET MISE EN PLACE DU G N RATEUR 1 Localiser le site de montage aussi pr s que possible du commutateur de transfert et de l alimentation en c
135. y conecte la carga a los contactos principales 2 Conecte la bobina del contactor a los terminales dell LSM deseado contactor 1 2 3 o 4 en la tira terminal 3 Conecte los contactores de corte de alimentaci n adicionales en forma similar NOTA Ser necesario determinar el orden del corte de las cargas conectadas y conectar las cargas al LSM en ese orden Uno es la m s alta prioridad y cuatro es la prioridad m s baja CUIDADO Realice pruebas funcionales en el orden exacto presentado en este manual o se har da o al interruptor IMPORTANTE Antes de proceder con las pruebas funcionales lea y aseg rese de que todas las instrucciones e informaci n en esta secci n hayan sido entendidas Asimismo lea la informaci n e instrucciones de las etiquetas y calcoman as fijadas al interruptor Notar cualquier opci n o accesorios que puedan estar instalados y revise su operaci n NOTA Esta prueba se puede realizar con el servicio p blico o el generador conectado a las cargas Sin embargo si el generador est abasteciendo a las cargas y hay sobrecarga el controlador puede haber apagado ya ciertas cargas Presione el bot n de TEST prueba en el controlador de carga Esta funci n desconectar todas las cargas controladas por el controlador El controlador de carga luego reconectar cada carga en forma pausada como se describe en el manual del propietario del interruptor de transferencia PRUEBAS DE F
136. y de construcci n locales federales y estatales As como cualquier generador esta unidad debe instalarse de acuerdo con los est ndares actuales NFPA 37 y NFPA 70 as como cualquier otro c digo federal estatal y local sobre distancias m nimas desde otras estructuras PREPARACI N DEL SITIO Y UBICACI N DEL GENERADOR 1 Ubique el area de montaje lo m s cerca posible al interuptor de transferencia y fuente de combustible Deje adecuado espacio alrededor del rea para acceso de servicio revise el c digo local y col quelo lo suficientemente alto para evitar que el agua alcance al generador Elija un espacio abierto que proporcionar un flujo de aire adecuado y sin obstrucciones ver la secci n de Ubicaci n en el manual del propietario 2 Coloque la unidad para que los respiraderos no se atoren con hojas c sped nieve o residuos Aseg rese de que los humos del escape no ingresen al recinto a trav s de aleros ventanas ventiladores u otros ingresos de aire 40 Cave un rea rectangular de aproximadamente cinco pulgadas de profundidad y seis pulgadas m s largo y ancho que la huella del generador con una pel cula de poliuretano y llene con gravilla o piedra chancada Compacte y nivele la piedra Se puede vertir una capa de concreto si se desea 3 Inspeccione si el generador tiene da os por el embarque y si es necesario presente un reclamo con el transportador Retire las bandas que sos