Home

PC5108FLR v2.0 Installation Instructions

image

Contents

1. JO TAMVAUXRED BLK YEL GRN Zi COM Z2 Z3 COM Z4 Z5 COM Z6 Z7 COM Z8 a S TO COM ee VAUX 12VDG LIMITED AT 100mA YEL RI TO DEVICES REQUIRING POWER KEYBUS TO lt gt PRECEDING l KEYBUS TO EXPANSION ax ADDITIONAL MODULE OR RH gt EXPANSION L MODULES PANEL e gt TAM Used fo tamper the cabinet in which the PCS1O8FLR is mounted Connect a nor mally closed NC switch across TAM and BLK If the tamper is not being used connect a piece of wire across TAM and BLK to remove the trouble condition 29007 m TM PowerSeries SECURITY SYSTEM 1 492R00 There is a built in tamper switch on the expander module located in the top left corner of the circuit board If the cabinet in which the PC5108FLR is mounted has the hardware required to depress this tamper switch do not connect anything to the TAM terminal VAUX Used to provide power for devices Maximum current draw is not to exceed 100 mA Connect the positive lead of powered devices to VAUX and the negative to BLK or any COM terminal KEYBUS The 4 wire KEYBUS connection is used by the panel to communicate with the module Connect the RED BLK YEL and GRN terminals to the KEYBUS terminals on the PC1616 PC1832 PC1864 amp PC5020 main control Z1 to Z8 Wire the zones according to the description found in the control panel Instal lation Manual Enclosures The P
2. 100mA El LI YEL RI A los dispositivos que requieren energ a KEYBUS AL ROJO KEYBUS MODULO DE lt lt ji z A TECLADOS EXPANSI N O AL NEGRO ADICIONALES Y PANEL DE CONTROL AWARIILO M DULOS PRECEDENTE lt lt gt DE EXPANSI N VERDE TAM Utilizado para violar la caja en la cual est instalado el PC5108FLR Conecte un interruptor normalmente cerrado NC a los terminales TAM y BLK Si la violaci n no es utilizada conecte un pedazo de hilo a los terminales TAM y BLK para eliminar la condici n de problemo Hoy un interruptor antiviolaci n integrado en el m dulo de expansi n ubicado en la esquina superior izquierda de la tarjeta de circuitos Si la caja en que esta instalado el PCSLOBFIR tiene el equipo necesario para presionar ese interruptor antiviolaci n no conecte cualquier elemento al terminal TAM 2900 7492R001 m TM PowerSeries SECURITY SYSTEM VAUX Utilizado para proveer alimentaci n a los dispositivos El consumo m ximo de corriente no puede exceder 100 mA Conecte el polo positivo de los dispositivos alimentados al VAUX y el negativo al BLK o a cualquier terminal COM KEYBUS La conexi n del bus KEYBUS de cuatro hilos es utilizada por el panel para la comunicaci n con el m dulo Conecte los terminales RED BLK YEL y GRN a los terminales KEYBUS del panel de control principal de los modelos PC1616
3. PC1832 PC1864 y PC5020 Z1 a Z8 Conecte los hilos de las zonas seg n la descripci n detallada en el Manual de Instalaci n del panel de control Cajas de protecci n El PC5108FLR puede instalarse en las cajas de protecci n met licas listadas a continuaci n Los interruptores antiviolaci n pueden instalarse en todas los cajas de protecci n incluyendo la protecci n contra apertura de la puerta y o renovaci n de la posici n de instalaci n Las puertas pueden protegerse por tornillos o cerraduras e Modelo PC5003C puerta amovible hecho de acero de 226a pintado dimensiones 248 mm L x 298 mm A x 76 mm A peso 1 500 g e Modelo PC5003C puerta pivotante hecho de acero con 1 2 mm de espesor pintado dimensiones 248 mm L x 298 mm A x 76 mm A peso 2 500 g e Modelo Power UCI hecho de acero de 18 Ga pintado dimensiones 315 mm L x 319 mm A x 100 mm A peso 3 150 g Modelo PC4DO3C hecho de acero de 186a pintado dimensiones 230 mm L x 180 mm A x 75 mm P peso 1 050 g Configuraciones de los puentes Se puede utilizar el m dulo PC5108FLR para agregar hasta ocho zonas de respuesta r pida de circuito con hilo al panel de control PC1616 PC1832 PC1864 PC5020 consulte el Manual de Instalaci n para lograr instrucciones completas acerca de la instalaci n Puentes El PCSIO8FLR funcionar en un nico grupo de ocho zon
4. 387 3630 Canada y EEUU 905 760 3036 Impreso en Canada
5. C5708FLR can be installed in the metal enclosures listed below Tamper protection switches can be installed on all enclosures including door opening protection and or removal from the mounting position Doors can be secured using screws or keylock e Model PC5003C removable door made of 226a steel painted dimensions 248mm L x 298mm W x 76mm H weight 1500g e Model PC5003C hinged door made of 1 2mm thick steel painted dimensions 248mm L x 298mm W x 76mm H weight 2500g e Model Power UCI made of 18Ga steel painted dimensions 31 5mm L x 31 9mm W x 100mm H weight 3150g e Model PC4003C made of 186a steel painted dimensions 230mm L x 180mm W x 75mm D weight 1050g Jumper Settings The PC5108FLR module can be used Expander Zones Jumpers Zones Assigned to add up to 8 additional hardwired Group A Zones o IT 17 1 13 fast loop response zones fo the GroupB not used PC1616 PC1832 PC1864 or ON ON ON Zones Disabled PC5020 control panel see Installa OFF ON ON Zones 9 16 tion Manual for complete installation m a 4 o H d ones Z3 instructions ON TON TOR fomes 3340 Jumpers OFF ON OFF Zones 41 48 A ON OFF OFF Zones 49 56 The PCS1OBFLR will operate in a sin arr lors lotr Hance 57 44 gle group of eight zones Refer to the following jumper settings To Add Hardwired Zones to a Control Panel Connect module to the Keybus with
6. PC5108FLR v2 0 Installation Instructions 8 Zone Expander Module This Installation sheet shall be used in conjunction with the Installation Manual of the DSC equipment to which PC5108FLR is connected or powered from e g alarm controller power supply etc The PC5108FLR module can be used to extend up to 8 hardwired fast loop response zones on the compatible DSC Alarm Controllers models PC5020 PC1864 PC1832 and PC1616 The fast loop response will be approximately 25ms General PC5108FLR may be installed in the same metallic cabinet as the alarm controller power supply model Power UCT PC5003C or in a separate enclosure PC40030 Internal and or external wiring for the PC5108FLR shall be routed supported clamped or secured in a manner that reduces the likelihood of a excessive strain on wire and ferminal connections b loosening of terminal connections and c damage of conductor insulation Specifications e Temperature range 10 C to 55 C e Relative Humidity 93 non condensing e Input rating 12V0 135mA provided by the alarm controller or separate power supply e Board current draw 35mA set and unset state e Board dimensions 45mm x 92mm e VAUX output ratings 12VDC 15 10 when Input voltage is between 85 to110 of rated value and output current is between OmA 100mA max e Ressetable fuse PTC used on circuit board instead of replaceable fuses Terminal Descriptions PC5108
7. as Consulte las configuraciones de puentes a continuaci n Zonas de exp Puentes Zonas atrib Grupo Zonas T 8 JI IZ J3 Grupo B no utilizado ACT ACT ACT Zonas deshab DES ACT ACT Zonas 9 16 ACT DES ACT Zonas 17 24 DES DES ACT Zonas 25 32 ACT ACT DES Zonas 33 40 DES ACT DES Zonas 41 48 ACT DES DES Zonas 49 56 DES DES DES Zonas 57 64 Para agregar zonas con hilo a un panel de control Conecte el m dulo al terminal Keybus con el panel apagado Configure los puentes en el m dulo Encienda el sistema Entre en la secci n 902 y espere 1 minuto Entre en la secci n 903 para verificar si el m dulo est supervisado Defina las zonas en las secciones 002 004 para el panel de control PC1616 PC1832 PC1864 6 PC5020 7 Agregue las zonas a la partici n apropiada en las secciones 202 265 LIMITED WARRANTY Digital Security Controls warrants that for a period of twelve months from the date of purchase the product shall be free of defects in materials and workmanship under normal use and that in fulfilment of any breach of such warranty Digital Security Controls shall at its option repair or replace the defective equipment upon return of the equipment to its factory This warranty applies only to defects in parts and workmanship and not to damage incurred in shipping or handling or damage due to causes beyond the control of Digital Security Controls such as lightni
8. d properly in strict accordance with the manufacturer s instructions may cause interference to radio and television reception It has been type tested and found to comply with the limits for Class B device in accordance with the specifications in Subpart B of Part 15 of FCC Rules which are designed to provide reasonable protection against such interference in any residential installation However there is no guarantee that interference will not occur in a particular installation If this equipment does cause interference to television or radio reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Re orient the receiving antenna Relocate the alarm control with respect to the receiver Move the alarm control away from the receiver Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits Tf necessary the user should consult the dealer or an experienced radio television technician for additional suggestions The user may find the following booklet prepared by the FCC useful How to Identify and Resolve Radio Television Interference Problems This booklet is available from the U S Government Printing Office Washington D C 20402 Stock 004 000 00345 4 CE e 2008 Digital Security Controls Toronto Canad www dsc com O Ss Cc Soporte t cnico 1 800
9. elos PC5020 PC1864 PC1832 y PC1616 La espuesta r pida del circuito ser de aproximadamente 25 ms General El PC5108FLR puede instalarse en la misma coja met lica del controlador de alarma fuente de alimentaci n modelo Power UCI PC5003C o en un compartimiento separado PC40030 El cableado interno y o externo del PC5108FLR debe orientarse soportarse fijarse o protegerse de manera en reducir la probabilidad de a tensi n excesiva bajo lo hilos y conexiones de los terminales b aflojado de las conexiones de los terminales y c da os al aislamiento de los conductores Especificaciones Rango de temperatura 10 C a 55 C e Humedad Relativa 93 sin condensaci n e Tensi n nominal 12 Vcc 135 mA prove da por el controlador de alarma o fuente de alimentaci n en separado e Consumo de corriente de la tarjeta 35 mA ajustado y no ajustado Dimensiones de la tarjeta 45 m mm e Tensi n de salida VAUX 12 Vcc 15 10 cuando la tensi n de entrada est entre 85 110 del valor nominal y la corriente de salida est entre 0 mA y 100 mA como m ximo e Fusible posible de reiniciar PTC utilizado en la tarjeta de circuitos env s de fusibles sustituibles Descripciones de los terminales gt lt ol lt or Bor Ja J5 Eos a PC5108 DO TAMVAUXRED BLK YEL GRN Zi COM Z2 Z3 COM Z4 Z5 COM Z6 Z7 COM ZB COM gai VAUX 12V0C LIMITED AT
10. f to modify or to change this warranty nor to assume for it any other warranty or liability concerning this product In no event shall Digital Security Controls be liable for any direct or indirect or consequential damages loss of anticipated profits loss of time or any other losses incurred by the buyer in connection with the purchase installation or operation or failure of this product Warning Digital Security Controls recommends that the entire system be completely tested on a regular basis However despite frequent testing and due to but not limited to criminal tampering or electrical disruption it is possible for this product to fail to per form as expected FCC COMPLIANCE STATEMENT CAUTION Changes or modifications not expressly approved by Digital Security Controls could void your authority to use this equipment This equipment generates and uses radio frequency energy and if not installed and used properly in strict accordance with the manufacturer s instructions may cause interference to radio and television reception It has been type tested and found to comply with the limits for Class B device in accordance with the specifications in Subpart B of Part 15 of FCC Rules which are designed to provide reasonable protection against such interference in any residential installation However there is no guarantee that interference will not occur in a particular installation If this equipment does cause interference to televi
11. ng excessive voltage mechanical shock water damage or damage arising out of abuse alteration or improper application of the equipment The foregoing warranty shall apply only to the original buyer and is and shall be in lieu of any and all other warranties whether expressed or implied and of all other obligations or liabilities on the part of Digital Security Controls This warranty contains the entire warranty Digital Security Controls neither assumes responsibility for nor authorizes any other person purporting to act on its behalf to modify or to change this warranty nor to assume for it any other warranty or liability concerning this product In no event shall Digital Security Controls be liable for any direct or indirect or consequential damages loss of anticipated profits loss of time or any other losses incurred by the buyer in connection with the purchase installation or operation or failure of this product Warning Digital Security Controls recommends that the entire system be completely tested on a regular basis However despite frequent testing and due to but not limited to criminal tampering or electrical disruption it is possible for this product to fail to perform as expected FCC COMPLIANCE STATEMENT CAUTION Changes or modifications not expressly approved by Digital Security Controls could void your authority to use this equipment This equipment generates and uses radio frequency energy and if not installed and use
12. sion or radio recep tion which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Re orient the receiving antenna e Relocate the alarm control with respect to the receiver Move the alarm control away from the receiver e Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits If necessary the user should consult the dealer or an experienced radio television technician for additional suggestions The user may find the following booklet prepared by the FCC useful How to Identify and Resolve Radio Television Interference Problems This book let is available from the U S Government Printing Office Washington D C 20402 Stock 004 000 00345 4 CE 2008 Digital Security Controls Toronto Canada www dsc com Tech Support 1 800 387 3630 Canada 8 U S 905 760 3036 Printed in Canada Instrucciones de instalaci n del PC5108FLR M dulo expansor de 8 zonas Este folleto de instalaci n debe utilizarse junto con el Manual de Instalaci n del equipo de DSC al cual se conectar el PC5108FLR o desde donde recibir alimentac n Ej controlador de alarma fuente de alimentaci n etc Se puede utilizar el m dulo PC5108FLR para ampliar el sistema con hasta ocho zonas de respuesta r pida de circuito con hilo en controladores de alarmas DSC compatibles que son los mod
13. the panel powered down Set the jumpers on the module Power up the system Enter section 902 and wait 1 minute Enter section 903 to verify that the module is supervised Define the zones in sections 002 004 for PC1616 PC1832 PC1864 or PC5020 Add the zones to the appropriate partition in sections 202 265 DSC LIMITED WARRANTY Digital Security Controls warrants that for a period of twelve months from the date of pur chase the product shall be free of defects in materials and workmanship under normal use and that in fulfilment of any breach of such warranty Digital Security Controls shall at its option repair or replace the defective equipment upon return of the equipment to its factory This warranty applies only to defects in parts and workmanship and not to damage incurred in shipping or handling or damage due to causes beyond the control of Digital Security Controls such as lightning excessive voltage mechanical shock water damage or damage arising out of abuse alteration or improper application of the equipment The foregoing warranty shall apply only to the original buyer and is and shall be in lieu of any and all other warranties whether expressed or implied and of all other obligations or liabilities on the part of Digital Security Controls This warranty contains the entire warranty Digital Security Controls neither assumes responsibility for nor authorizes any other person purport ing to act on its behal

Download Pdf Manuals

image

Related Search

Related Contents

PDF - Eyetec  Catalogue Reproduction Technology Equine  Manual del operador Desfibrilador - Tecno-Gaz  Manual del Usuario - Ingegas de Colombia  別紙2 (第6条関係) 入 札 説 明 書 平成2 6年6月 2 日付けで  Gebruiksaanwijzing 2 User manual 13 Notice d`utilisation 23  Bedienungsanleitung  8540780 • 25. Juni 2014 • Rev.21  Akupressurmatte  iVision 3D User Manual for Barco  