1. 1 18 17 e 1 5 1 10 lt gt 1 11 1 12 1 13 1 16 1 14 1 15 1 7 TT al j P g 4 Manual de instrucciones 50171146 Revisi n 1 Septiembre 08 ENGLISH Put the microscope in a horizontal plane stable table having a safety area of at least 30 cm per side Do not place the microscope near any warm supply burners blowlamps etc nor expose it directly to the sun Avoid vibrations dust and dry environments During operation dangerous materials such as flammable or pathological substances must be out of the working area When you are not using the microscope for a long period of time please make sure it is unplugged from the net in order to avoid possible accidents It is essential to have the equipment switched off and unplugged from the net before cleaning checking components or replacing any piece e g replacement of a fuse Never try to repair the microscope by yourself since you will lose the warranty and may provoke damages to the general operating system or the electrical installation as well as injuries to the people that usually handle the equipment burns hurts Made under the European regulations for electrical security electromagnetic compati bility and security on machines 5 MAINTENANCE AND CLEANING To get the best results and a higher duration of this equipment it is essential to follow the processes of use Note All the processes of use mentioned below will not have any val
2. 08 CASTELLANO Coloque el cabezal binocular y ajuste firmemente el tornillo de sujeci n 2 2 mediante la llave Allen suministrada Fig 2 Inserte los oculares Haga bajar la platina mediante los mandos de enfoque macro Enrosque los objetivos en el rev lver de manera que sigan un orden ascendente 4x 10x 40x 60x cuando el rev lver sea girado en el sentido de las agujas del reloj Si es necesario inserte una de las placas accesorias suministradas en la hendidura del tubo intermedio 1 7 Dicha hendidura est orientada de tal manera que las placas se insertan a 45 de las direcciones de vibraci n preferentes del polarizador y analizador Si lo desea coloque el carro mec nico sobre la platina y fijelo El equipo se suministra con un cable de red Schuko est ndar Inserte el cable de ali mentaci n de corriente alterna CA a la base de corriente 220 V 50 Hz 10 provista de toma de tierra y por el otro extremo al conector del equipo Ni el fabricante ni el distribuidor asumir n responsabilidad alguna por los da os ocasionados al equipo instalaciones o lesiones sufridas a personas debido a la inob servancia del correcto procedimiento de conexi n el ctrica La tensi n debe ser de 220V 50Hz 10 Cuando no vaya a hacer uso del microscopio durante largos periodos de tiempo ase gurese de que est desconectado de la red y prot jalo del polvo evitando asi posibles acci dentes y prolongando la vida util del equipo Mod
3. V 50 Hz 10 Neither the manufacturer nor the distributor will assume any responsibility for the damages produced to the equipment during its installation or damages to persons suf fered by the improper use of the electric connection The tension should be 220 V 50 Hz 10 If you are not using the microscope for a long period of time please make sure it is dis connected from the net and protected from dust this way you will avoid accidents and will extend its working life Operating mode Press the power on off 1 17 and turn the adjusting knob 1 18 until the light intensity is adequate Put the sample on the stage Focusing Using the objective with lesser magnification 4x raise the stage by using the coarse adjustment knob 1 15 until the image of the sample appears Then move the fine adjus tment knob 1 16 until the image is focused By turning the nosepiece put an objective with higher magnification 10x it will only be necessary to adjust focusing with the fine adjustment knob Focus tension adjustment figure 3 Turning the friction control ring 3 1 toward the rear of the microscope increases the tension and toward the front of the microscope loo sens it Avoid loosening it excessively since this could produce the fall of the stage toge ther with problems on focusing accuracy Figure 3 3 1 Friction control ring 3 2 Focus limit control A j Page 18 Instruction manual 50171146 Version 1 September
4. according to the CE marking regulations as well as empha sizing the ergonomics and security for its user The correct using of the equipment and its good quality will permit you to enjoy this equipment for years The improper use of the equipment can cause accidents and electric discharges circuit breakers fires damages etc Please read the point of Maintenance where we expose the security notes TO GET THE BEST RESULTS AND A HIGHER DURATION OF THE EQUIP MENT IT IS ADVISABLE TO READ THOROUGHLY THIS MANUAL BEFORE OPERATING WITH THE EQUIPMENT Please bear in mind the following This manual is inseparable from the Zuzi polarizing microscope 146P so it should be available for all the users of this equipment You should carefully handle the microscope avoiding sudden movements knocks free fall of heavy sharp objects on it Avoid spilling liquids inside the equipment Never dismantle the different pieces of the microscope to repair it yourself since it could produce a defective use of the whole equipment and a loss of the product warranty as well as injuries on people that handle the microscope To prevent fire or electric discharges avoid dry or dusty environments In case it may happen unplug the equipment immediately If you have any doubt about setting up installation or functioning do not hesitate in contacting your wholesaler You can also tell us any doubts or suggestions you have by contacting Zuzi Technical Assistanc
5. el tubo intermedio y ajuste firmemente el tornillo de sujeci n 2 1 mediante la llave Allen suministrada Fig 2 2 1 Tornillo de sujeci n del tubo intermedio 2 2 Tornillo de sujeci n del cabezal A j P g 6 Manual de instrucciones 50171146 Revisi n 1 Septiembre 08 ENGLISH Figure 3 ae E gt Fa AI Pre focusing or focus limit control figure 3 After focusing the sample with the low magnification objective rotate the focus limit control 3 2 toward the front of the micros cope to set the upper limit on the coarse adjustment movement After changing samples or objectives focusing is easily accomplished by rotating the coarse adjustment knob to reach the pre focused position then making fine adjustments with the fine adjustment knob The fine adjustment is not affected by using the upper focus limit control Diopter compensation and interpupillary distance adjustment Diopter compensation adjust to zero the dioptre compensation ring placed at the left eyepiece holder then looking through the right eyepiece focus the sample specimen using the coarse and fine adjustment knobs Once the sample is focused look through the left eyepiece and adjust the dioptre compensation ring until obtaining a clear sharp image Interpupillary distance Adjust the interpupillary distance by separating or joining the eyepieces until there is a total fusion
6. is necessary to change the fuse loosen the protective lid that is at the back of the microscope over the socket change the fuse and place it in the same position putting the protective lid again Figure 6 Cleaning NOTE Zuzi recommends using the microscope cleaner kit code 89000001 Never use scourers or substances that can grate for cleaning metallic parts such as stain less steel aluminium coatings etc as they damage the microscope and produce an early ageing of the equipment Use a fluff free cloth dampened with soaped water that does not contain abrasives TF A da dd i j Page 22 Instruction manual 50171146 Version 1 September 08 CASTELLANO ATENCI N NO SE ADMITIR NING N APARATO PARA REPARAR QUE NO EST DEBIDAMENTE LIMPIO Y DESINFECTADO NDICE DE IDIOMAS Castellano 2 12 NDICE DE CONTENIDOS 1 APLICACIONES DEL INSTRUMENTO ccc ccecccececesececestecceseecscecsescecseacenacecsesees 3 DE AIN ae eee een ea Eee ee eee eee 4 3 ESPECIFICACIONES T CNICAS naco 5 4 INSTALACI N PUESTA EN MARCHA oooccononononononicnononcnnnnnnannonnnnnsororororoncncnrnnanananos 5 5 MANTENIMIENTO Y LIMPIEZA cccceccsesssscsscsessescsscsscsesecseesesecsecseseesecsesessecaeseeaeens 10 ANEXO TE CER TIFICADO CE as 24 1 APLICACIONES DEL INSTRUMENTO El microscopio Zuzi 146P equipado con ptica corregida al infinito ofrece unas exce lentes prestaciones t cnicas para la observaci n de m
7. of the two images Note once the values of interpupillary distance and dioptre compensation are found it will be very useful to learn them by heart mostly if the microscope is shared with other users This is highly advisable to avoid repeating the adjustment each time the micros cope is used Abbe condenser adjustment Figure 4 4 1 Condenser height adjustment knob 4 5 Condenser holding screw 4 2 Condenser 4 6 Condenser centering screw 4 3 Condensing lens lever 4 7 Pre condenser with field diaphragm 4 4 Aperture diaphragm Version 1 September 08 Instruction manual 50171146 Page 19 a J ENGLISH Put the binocular head and tighten firmly the holding screw 2 2 by using the supplied Allen key Fig 2 Insert the eyepieces Lower the stage by using the coarse adjustment knob 1 15 Screw the objectives on the nosepiece so as when it is turned clockwise the objectives follow an ascendant way 4x 10x 40x 60x If necessary insert one of the compensator plates in the corresponding slot 1 7 in the intermediate tube The plates are inserted at 45 from the preferential directions of vibra tion of the polarizer and analyzer If wanted put the attachable mechanical stage and fix it firmly The microscope is supplied with a Schuko standard wire Please insert the wire that feeds the AC electric current in the base of current 220 V 50 Hz 10 provided with earth wire and the other end to the microscope connector The tension should be 220
8. proceder le per mitir n disfrutar del equipo por muchos a os El uso incorrecto o indebido del equipo puede dar lugar a accidentes descargas el ctri cas cortocircuitos fuegos lesiones etc Lea el punto de Mantenimiento donde se recogen aspectos de seguridad LEA DETALLADAMENTE ESTE MANUAL DE INSTRUCCIONES ANTES DE OPERAR CON ESTE EQUIPO CON EL FIN DE OBTENER LAS MAXIMAS PRES TACIONES Y UNA MAYOR DURACI N DEL MISMO Tenga especialmente presente lo siguiente Este manual es parte inseparable del microscopio de polarizaci n por lo que debe estar disponible para todos los usuarios del equipo Debe manipularse siempre con cuidado evitando los movimientos bruscos golpes cai das de objetos pesados o punzantes evite el derrame de l quidos en su interior Nunca desmonte el equipo para repararlo usted mismo adem s de perder la garant a podr a producir un funcionamiento deficiente de todo el equipo as como da os a las per sonas que lo manipulan Para prevenir fuego o descargas el ctricas evite los ambientes secos y polvorientos Si esto ocurre desenchufe inmediatamente el equipo de la toma de corriente Cualquier duda puede ser aclarada por su distribuidor instalaci n puesta en marcha funcionamiento Usted puede tambi n mandarnos sus dudas o sugerencias a la siguien te direcci n de correo del Servicio T cnico Zuzi asistencia auxilab es o bien llamando al Tel 807117040 0 30 Euros min Este equipo e
9. AUXILAB S L Material de laboratorio DECLARACION DE CONFORMIDAD CE CE DECLARATION OF CONFORMITY DECLARATION DE CONFORMITE CE El fabricante The manufacturer Le furnisseur AUXILAB S L Declara que el equipo Declare that the equipment Declar que lappareil MICROSCOPIO DE POLARIZACION POLLARIZING MICROSCOPE MICROSCOPE POLARISANT C digo Code Code 50171146 Modelo Model M dele 146 P Cumple las siguientes directivas Meet the following directives Accomplit les directives suivantes 73 23 CE Directiva de seguridad el ctrica 89 336 CE Directiva de Compatibilidad electromagn tica CEM Directive for electrical safety Directive for electromagnetic compatibilit y EMC Directive the s curit lectrique Directive the compatibilit electromagn tique CEM Cumple las siguientes Normas Meet the following Standars Accomplit les normes suivantes EN 61326 Material el ctrico para medida control y uso en laboratorio Requisitos de compatibilidad electromagn tica CEM Electrical equipment for measurement control and laboratory use EMC requirements Mat riel lectriques de mesure de commande et laboratorie Prescriptions relatives ala CEM EN 61010 1 Requisitos de seguridad de equipos el ctricos de medida control y uso en laboratorio Parte 1 Requisitos generales Safety requirements for electrical equipments for measurement control and laboratory use Part 1 General requierements R gle
10. Analizador Lente Bertrand Placas accesorias Platina Condensador Diafragmas Lampara CASTELLANO 3 ESPECIFICACIONES TECNICAS 50171146 146P Corregida al infinito Binocular tipo Siedentopf inclinado 30 y rotatorio 360 Distancia interpupilar 55 75 mm compensaci n di ptrica 2 oculares WF10x 22 mm 1 ocular WF10x 20 mm con ret cula Cu druple 4x A N 0 10 10x A N 0 25 40x R A N 0 65 60x R A N 0 85 Plano acrom ticos centrables individualmente Giratorio 360 Giratorio 90 Deslizable de la l nea ptica Placa de yeso 1 A placa de mica 1 4 A y cu a de cuarzo Circular 160 mm giratoria 360 y graduada resoluci n 0 1 Pinzas fijas o carro mec nico con recorrido 35x25 mm Abbe A N 1 25 con lente condensadora deslizable de la l nea ptica De campo y apertura Hal gena 12 V 30 W CA 85 V 230 V 4 INSTALACI N PUESTA EN MARCHA Inspecci n preliminar Desembale el equipo retire el pl stico que lo envuelve y quite la protecci n de polies p n en que viene encajado Retire todas las protecciones y sin conectar el microscopio a la red el ctrica aseg rese de que no presenta ning n da o debido al transporte De ser as comun quelo inmediatamente a su transportista o suministrador para que pueda hacer las debidas reclamaciones en el plazo establecido Guarde el embalaje ya que siempre se deben realizar las devoluciones en su embalaje o
11. ONES TECNICAS Code Model Optics Head Eyepieces Nosepiece Objectives Polarizer Analyzer Bertrand lens Compensator plates Stage Condenser Diaphragms Lamp 50171146 146P Infinity corrected Binocular Siedentopf type 30 inclined and 360 rotary Interpupillary distance 55 75 mm Diopter compensation 2 eyepieces WF10x 22 mm 1 eyepieces WF10x 20 mm graduated Quadruple 4x A N 0 10 10x A N 0 25 40x R A N 0 65 60x R A N 0 85 Plan achromatic can be centered individually Rotary 360 Rotary 90 Removable from optical path Gypsum 1 A mica 1 4 A and quartz wedge Round 160 mm rotary 360 and graduated resolution 0 1 Fixed clamps or mechanical stage with movement range 35x25 mm Abbe N A 1 25 with condensing lens removable from the optical path Field and aperture Halogen 12 V 30 W CA 85 V 230 V 4 INSTALLATION SETTING UP Unwrap the microscope take off the involving plastic and take off the polyspan pro tection in which it comes fitted Take off all the protective items and without connecting the microscope to the net make sure that it does not present any damage because of the shipment In case the microscope presents any damage tell it immediately to your trans port agent or dealer so that they can make the claims in the correct time limit Please keep the original wrapping you will always need it for returns enclosed with all the ac
12. QUIPMENTS ARE NOT PROPERLY CLEAN AND TECHNICAL SERVICE INSTRUCTIONS ON ENVIRONMENTAL PROTECTION gt Do not dispose of this product in the usual household garbage at the end of its life b cycle hand it over at a collection point for the recycling of electrical and electronic appliances The symbol on the product the instructions for use or the packing will inform about the methods for disposal The materials are recyclable as mentioned in its marking By recycling material recycling or other forms or re utilization of old appliances you are making an important contribution to protect our environment Please inquire at the community administration for the authorized disposal loca tion Version 1 September 08 Instruction manual 50171146 Page 23 al j ENGLISH Adjust the centering screws until the objective is perfectly centered IMPORTANT before changing the lamp bulb or the fuse make sure that the microscope is disconnected from the net Check you are using the proper lamps as other types can provoke malfunction Changing the lamp If the lamp is blown up replace for another one making sure it is a 12 V 30 W Zuzi ori ginal one Please take care and do not touch the lamp with bare hands Do not use lamps with a higher power as they could provoke over heating or any malfunction For replacing the lamp remove the precondenser Figure 5 Replace the lamp holding it firmly ry B Changing the fuse If it
13. cessories supplied Please check that all the accessories are enclosed with the equipment Binocular head Intermediate tube 2 Eyepieces WF10x 22 mm and 1 eyepiece WF10x 20 mm graduated Plan achromatic objectives 4x 10x 40x and 60x Compensator plates gypsum 1 A mica 1 4 A and quartz wedge TF gi j Page 16 Instruction manual 50171146 Version 1 September 08 CASTELLANO Ajuste la apertura del diafragma de apertura 4 4 entre el 70 80 de la apertura num rica del objetivo en uso 4 1 Mando regulaci n altura del conden 4 5 Tornillo de sujeci n del condensador sador 4 6 Tornillos para centrado del condensa 4 2 Condensador dor 4 3 Palanca lente condensadora 4 7 Precondensador con diafragma de 4 4 Diafragma de apertura campo Figura 4 41 4 4 4 2 N AY L E re 4 6 47 Observaci n ortogonal El polarizador est situado en el paso del haz de luz por lo que las observaciones se rea lizan bajo luz polarizada Gire el polarizador 1 13 y el analizador 1 6 hasta que ambos queden en posici n 0 De este modo ambos filtros se encuentran colocados de forma ortogonal polarizador direcci n E O y analizador direcci n N S Cuando utilice el objetivo de 10x o uno de menor aumento retire la lente condensadora 4 3 de la trayectoria del haz de luz Cuando utilice el objetivo de 20x o uno de mayor aumento coloque la lente condensadora en la traye
14. ctoria del haz de luz y sit e el conden sador en su posici n m s elevada Inserte las placas accesorias de yeso mica o cuarzo seg n sus necesidades Observaci n conosc pica La observaci n conosc pica se realiza con objetivos de 20x o de mayor aumento Coloque la lente condensadora en la trayectoria del haz de luz Coloque la lente Bertrand 1 4 en la trayectoria del haz de luz posici n B y c ntrela mediante los tornillos de centrado 1 5 Revisi n 1 Septiembre 08 Manual de instrucciones 50171146 P g 9 a j CASTELLANO Seguridad El microscopio debe ser utilizado por personal cualificado previamente que conozca el equipo y su manejo mediante el manual de uso Coloque el equipo sobre una mesa horizontal plana y estable creando un espacio libre de al menos 30 cm por cada lado No coloque el microscopio en zonas pr ximas a fuentes de calor mecheros sopletes ni exponga el equipo directamente a la luz del sol Evite las vibraciones el polvo y ambientes muy secos Durante su funcionamiento el material peligroso como l quidos inflamables o material patol gico deben estar fuera del rea de trabajo Cuando no vaya a hacer uso del equipo por largos per odos de tiempo aseg rese de que est desconectado de la red para evitar posibles accidentes Para cualquier manipulaci n de limpieza verificaci n de los componentes o sustituci n de cualquier componente ejemplo sustituci n de fusible es i
15. e Department by email to asistencia auxilab es or by telephone 34 807 117 040 0 30 Euros min This equipment is protected under the Warranties and consumer goods regulation 10 2003 Overhaul is not covered by the microscope warranty Operations made by non qualified staff will automatically produce a loss of the micros cope warranty Neither fuses nor accessories including their loss are covered by the product s warranty The warranty neither covers piece s deterioration due to the course of time Please make sure you keep the invoice either for having the right to claim or asking for warranty coverage In case you have to send the equipment to Zuzi Technical Assistance Department you should enclose the original invoice or a copy as guarantee Please do not forget filling the warranty certificate and send it before 15 days after the date of purchase Manufacturer reserves the right to modify or improve the manual or equipment Version 1 September 08 Instruction manual 50171146 Page 13 yi j
16. eja huellas en la bombilla por accidente l mpiela con un trapo suave No utilice l mparas de mayor potencia ya que podr a producir un sobrecalentamiento u otra mala funci n Para efectuar el cambio de l mpara retire el porta precondensador Figura 5 TY B Cambie la lampara agarrandola firmemente Cambio de fusible Si fuese necesario reemplazar el fusible extraiga la tapa protectora que se encuentra en la parte posterior del microscopio sobre la clavija de toma de corriente reemplace el fusi ble y vuelva a colocarlo en su misma posici n encajando de nuevo la tapa protectora Figura 5 TAL Pag 11 a J Revision 1 Septiembre 08 Manual de instrucciones 50171146 CASTELLANO Limpieza NOTA Zuzi le recomienda utilizar el kit de limpieza de microscopios Ref 89000001 Para la limpieza de las partes met licas acero inoxidable aluminio pinturas etc nunca utilice estropajos o productos que puedan rayar ya que deterioran el equipo limitando su vida util Para la limpieza del equipo recomendamos se utilice un trapo libre de pelusa humede cido con agua jabonosa que no contenga productos abrasivos Las lentes no deben ser desmontadas por el usuario Si hubiese cualquier suciedad en las superficies externas de las lentes limpielas con un pa o suave que no desprenda pelu sa humedecido con un poco de xilol o tolueno Para quitar el polvo que se haya posado sobre las
17. er to the sample must be the condenser Adjust the aperture of the field diaphragm 4 7 until it completely circumscribes the field of view Adjust the aperture diaphragm 4 4 to the 70 80 of the numerical aperture of the objective in use Orthogonal observation The polarizer is located in the optical path so observations are performed under polari zed light Turn the polarizer 1 13 and the analyzer 1 6 until both are in position 0 Thus both filters are in an orthogonal position polarizer in E W direction and analyzer in N S direc tion When using the 10x or a lower magnification objective remove the condensing lens 4 3 from the optical path When using the 20x or a higher magnification objective put the con densing lens into the light path and raise the condenser to the uppermost position Insert the complementary plates of gypsum mica or quartz if necessary Conoscopic observation Conoscopic observation is performed with the 20x or a higher magnification objective Put the condensing lens into the light path Put the Bertrand lens 1 4 into the light path position B and center it by using the centering screws 1 5 Security The microscope must be used by previously qualified staff that knows how to operate it thanks to the user manual TAL i j Page 20 Instruction manual 50171146 Version 1 September 08 Referencia Modelo Optica Cabezal Oculares Revolver Objetivos Polarizador
18. hacia el frente del microscopio para fijar el l mite superior del movimiento macrom trico Al cambiar de objetivo o muestra el enfoque se lleva a cabo f cilmente mediante el giro del mando macrom trico hasta alcanzar la posici n tope despu s ajuste el enfoque mediante el mando microm trico El mando microm trico no se ve afectado por el control de l mite de enfoque Compensaci n di ptrica y regulaci n de la distancia interpupilar Compensaci n di ptrica ajuste a cero el anillo de compensaci n di ptrica situado en el ocular izquierdo mirando por el ocular derecho enfoque la preparaci n accionando los mandos macrom trico y microm trico Una vez enfocada mire por el ocular izquierdo y ajuste el anillo de compensaci n di ptrica hasta visualizar una imagen n tida Si el obser vador tiene astigmatismo debe conservar sus gafas puestas Distancia interpupilar para la comodidad del usuario es crucial una correcta distancia entre oculares Regule la distancia interpupilar separando o juntando los oculares hasta conseguir una total fusi n de las dos im genes Nota Una vez hallados estos valores de distancia interpupilar y compensaci n di p trica ser muy til memorizarlos sobre todo si el microscopio es compartido por m s de un usuario para evitar tener que repetir la localizaci n de los valores id neos cada vez que el microscopio es manipulado Ajuste del condensador Abbe Figura 4 Regule la altura del condensad
19. lentes sople con una pera o l mpielo con un cepillo o pincel suave de pelo natural o mediante alguna gasa especial para len tes En las partes mec nicas utilice lubricantes no corrosivos teniendo especial cuidado en no tocar las partes pticas NOTA No desmonte las lentes de los objetivos ATENCI N NO SE ADMITIR NING N APARATO PARA REPARAR QUE NO EST DEBIDAMENTE LIMPIO Y DESINFECTADO INSTRUCCIONES SOBRE PROTECCI N DEL MEDIO AMBIENTE lt A No se deshaga de este equipo tirandolo a la basura ordinaria cuando haya termi b nado su ciclo de vida ll velo a un punto de recogida para el reciclaje de aparatos el c tricos y electr nicos No contiene elementos peligrosos t xicos para el humano pero una eliminaci n no adecuada perjudicar a al medio ambiente Los materiales son reciclables tal como se indica en la marcaci n Al reciclar materiales u otras formas de reutilizaci n de aparatos antiguos esta Ud haciendo una contribuci n importante a la protecci n del medio ambiente Por favor p ngase en contacto con la administraci n de su comunidad para que le asesoren sobre los puntos de recogida A gi j P g 12 Manual de instrucciones 50171146 Revisi n 1 Septiembre 08 ENGLISH Thank you for choosing this equipment We sincerely wish that you enjoy your Zuzi polarizing microscope 146P We highly recommend looking after this equipment accor ding to what is stated in this manual Zuzi develops its products
20. mprescindible apagar el equipo y desconectarlo de la toma de corriente No intente repararlo usted mismo adem s de perder la garant a puede causar da os en el funcionamiento general del equipo as como lesiones a la persona quemaduras heri das y da os a la instalaci n el ctrica Procure que no entre agua en ninguna parte ptica o de iluminaci n aunque stas se encuentren debidamente aisladas Si por cualquier causa sospecha que ha entrado agua o cualquier l quido desconecte el equipo inmediatamente ver Mantenimiento Fabricado seg n las directivas europeas de seguridad el ctrica compatibilidad electro magn tica y seguridad en m quinas 5 MANTENIMIENTO Y LIMPIEZA Para un adecuado funcionamiento del microscopio es necesario seguir algunas reco mendaciones Nota Todas las normas de utilizaci n citadas anteriormente carecer n de valor si no se realiza una continua labor de mantenimiento Siga las instrucciones y advertencias relativas a este manual Tenga este manual siempre a mano para que cualquier persona pueda consultarlo Utilice siempre componentes y repuestos originales Puede ser que otros dispositivos sean parecidos pero su empleo puede da ar el equipo El aparato dispone de un cable de red Schuko este debe conectarse a una toma de corriente que est conectada a tierra debiendo quedar a mano para poder desconectarlo en caso de emergencia No intente repararlo usted mismo adem s de
21. o de uso Pulse el interruptor de encendido 1 17 y gire el regulador 1 18 para ajustar la inten sidad de iluminaci n seg n sus necesidades Coloque la muestra sobre la platina Enfoque de la muestra Con el objetivo de menor aumento 4x suba lentamente la platina con el mando macro m trico 1 15 hasta que aparezca la imagen En este momento utilice el mando microm trico 1 16 para conseguir un ptimo enfoque Una vez enfocada la muestra con el objeti vo de 4x gire el rev lver hasta el objetivo de siguiente 10x nicamente necesitar reali zar un peque o ajuste con le mando microm trico para obtener el enfoque ptimo Ajuste de la tensi n del enfoque figura 3 girando el anillo de control de fricci n 3 1 hacia la parte de atr s del microscopio aumenta la tensi n del mando macrom trico y hacia la parte delantera del microscopio disminuye Se debe evitar aflojarlo excesivamen te ya que esto podr a causar una ca da involuntaria de la platina con los consiguientes problemas de precisi n en el enfoque 3 1 Anillo de control de fricci n 3 2 Control del l mite de enfoque Revisi n 1 Septiembre 08 Manual de instrucciones 50171146 P g 7 Zi j CASTELLANO Figura 3 ae Eo Pre enfoque o control del l mite de enfoque figura 3 despu s de enfocar la muestra con el objetivo de menor aumento gire la palanca de control del l mite de enfoque 3 2
22. or 4 1 seg n el objetivo en uso Cuanto mayor aumen to posea el objetivo m s cerca de la preparaci n deber estar el condensador Ajuste la apertura del diafragma de campo 4 7 hasta que circunscriba completamente el campo de visi n T Mm a j P g 8 Manual de instrucciones 50171146 Revisi n 1 Septiembre 08 ENGLISH Attachable mechanical stage Allen key Blue filter Net wire Lamp Plastic cover Fuse User s manual Objective centering keys Warranty certificate We will only accept the equipment return within 15 days after delivery provided it comes in its original wrapping Installation Before using this instrument it is convenient for you to familiarize with its components and basic essentials PLEASE READ THOROUGHLY THE INSTRUCTIONS BEFORE CONNECTING AND OPERATING WITH THIS EQUIPMENT Please put the microscope on top of a horizontal plane and stable table making a free space at least at 30 cm per side Do not put the microscope near any warm supply bur ners blowlamps nor expose it directly to the sun etc Avoid the presence of flamma ble or toxic products in the working area Put the intermediate tube and tighten firmly the holding screw 2 1 by using the sup plied Allen key Fig 2 2 1 Intermediate tube holding screw 2 2 Head holding screw z ES 1 Version 1 September 08 Instruction manual 50171146 Page 17 vi j CASTELLANO 3 ESPECIFICACI
23. perder la garant a puede causar da os en el funcionamiento general del equipo as como lesiones a la persona quemaduras heri TAL al j P g 10 Manual de instrucciones 50171146 Revisi n 1 Septiembre 08 2 DESCRIPTION 1 1 Binocular head 1 2 Eyepieces 1 3 Intermediate tube 1 4 Bertrand lens 1 5 Bertrand lens centering screws 1 6 Analyzer 1 7 Slot for inserting compensator plates 1 8 Nosepiece 1 9 objective centering screws 1 17 ENGLISH 1 10 Rotary stage 1 11 Stage fixing screw 1 12 Condenser 1 13 Polarizer 1 14 Pre condenser 1 15 Coarse adjustment knob 1 16 Fine adjustment knob 1 17 Power on off 1 18 Light intensity control Version 1 September 08 Instruction manual 50171146 Page 15 d ENGLISH TED THEY WOULD NOT BE ALLOWED TO REPAIR BY OUR TECHNICAL SERVICE i ATTENTION IF EQUIPMENTS ARE NOT PROPERLY CLEAN AND DISINFEC INDEX OF LANGUAGES INDEX OF CONTENTS 1 USES OF THE INSTRUMENT on eesesscssessosesseessssceseecnssecseesneceessecnessensesnecsossecneesoesenseese 14 2 DESERILITON outils 15 3 TECHNICAL SPECIFICATIONS oo ceecseesssesecseessecseeseesnesseeueesseeseeaecneeneeneeaenneensees 16 4 INSTALLATION SETTING UP 16 1 USES OF THE INSTRUMENT Zuzi microscope 146P equipped with infinity corrected optics offers excellent optical features for observing samples under polarizing light being of application in petro graphy mineralogy and materials chemist
24. riginal con todos los accesorios suministrados Compruebe los accesorios que usted debe recibir junto al equipo Cabezal binocular Tubo intermedio 2 Oculares WF10x 22 mm y 1 ocular WF10x 20 mm con ret cula Objetivos plano acrom ticos 4x 10x 40x y 60x Placas accesorias yeso 1 A mica 1 4 A y cu a de cuarzo Ta Manual de instrucciones 50171146 P g 5 a j Revisi n 1 Septiembre 08 CASTELLANO Carro mecanico con pinza Llave Allen Filtro azul Cable de red Lampara de recambio Funda Fusible Manual de instrucciones Llaves para centrado de los objetivos Certificado de garantia S lo aceptamos devoluciones de equipos en los 15 dias posteriores al envio y siem pre que vengan completos en su embalaje original Instalaci n Antes de comenzar a utilizar el instrumento es conveniente familiarizarse con sus com ponentes y fundamentos b sicos as como con las funciones de sus controles LEA DETALLADAMENTE ESTE MANUAL DE INSTRUCCIONES ANTES DE OPE RAR CON ESTE EQUIPO CON EL FIN DE OBTENER LAS MAXIMAS PRESTACIONES Y UNA MAYOR DURACI N DEL MISMO Coloque el microscopio sobre una mesa horizontal plana y estable creando un espacio libre al menos de 30 cm por cada lado No coloque el equipo en zonas pr ximas a fuentes de calor mecheros sopletes ni lo exponga directamente a la luz del sol etc Evite en el lugar de trabajo la presencia de productos inflamables o t xicos Coloque
25. ry as well as in histology and anatomical patho logy for studying birefringent structures crystalline structures pigments lipids amyloid deposits etc For this purpose the microscope is provided with a polarizing filter under the stage that only transmits light in N S direction and an analyzing filter located over the stage that transmits light in E W direction When both filters are in orthogonal position at an angle of 90 the light generated by the polarizer is extinguished and nothing is observed however if the sample is birefringent the structure will light up on a dark field TAL al J Page 14 Instruction manual 50171146 Version 1 September 08 CASTELLANO das y da os a la instalaci n el ctrica o equipos el ctricos cercanos En caso de aver a dir jase a su proveedor para la reparaci n trav s del Servicio T cnico de Zuzi Centrado de los objetivos Cada objetivo puede ser centrado individualmente en el mismo rev lver para alinearlo perfectamente con la trayectoria del haz de luz y as evitar posibles distorsiones de la ima gen Para ello inserte las llaves suministradas en los tornillos de centrado 1 9 situados a cada lado del objetivo Ajuste los tornillos hasta conseguir que el objetivo quede perfectamente centrado Cambio de l mpara Si se funde la l mpara reempl cela por una l mpara original Zuzi de 12 V 30 W tenien do cuidado de no tocar la ampolla con las manos desnudas Si d
26. s de s curit pour appareils lectriques de mesurage de r gulation et de laboratorie Partie 1 Prescriptions g n rales Fdo Alfonso Ainciburu Sanz DIRECTOR GERENTE BERIAIN a 13 de OCTUBRE de 2008 Pol Morea Norte Calle D N 6 31191 Beriain Navarra ESPA A Tel fono 34 948 310 513 Fax 34 948 312 071 948 310 500 correo auxilab es www auxilab com CIF B31072218 MICROSCOPIO DE POLARIZACI N POLARIZING MICROSCOPE MODELO MODEL MODELE 146P Este manual es parte inseparable del aparato por lo que debe estar disponible a todos los usuarios del equipo Le recomendamos leer atentamente el presente manual y seguir rigurosamente los proce dimientos de uso para obtener las m ximas prestaciones y una mayor duraci n del mismo This manual should be available for all users of these equipments To get the best results and a higher duration of this equipment it is advisable to read carefully this manual and follow the processes of use Revisi n 1 Septiembre 08 Manual de instrucciones 50171146 P g 1 CASTELLANO Gracias por haber adquirido este equipo Deseamos sinceramente que disfrute del microscopio de polarizaci n Zuzi 146P Le recomendamos que cuide el equipo conforme a lo expuesto en este manual Zuzi desarrolla sus productos seg n las directrices del marcado CE y haciendo hinca pi en la ergonom a y seguridad del usuario La calidad de los materiales empleados en la fabricaci n y el correcto
27. st amparado por la Ley de garant as y bienes de consumo 10 2003 No se consideran en garant a las revisiones del equipo La manipulaci n del equipo por personal no autorizado provocar la p rdida total de la garant a Los fusibles o accesorios as como la p rdida de los mismos no est n cubiertos por dicha garant a Tampoco estar n cubiertos por el periodo de garant a las piezas en su des gaste por uso natural Aseg rese de guardar la factura de compra para tener derecho de reclamaci n o pres taci n de la garant a En caso de enviar el equipo al Servicio T cnico adjunte factura o copia de la misma como documento de garant a Rellene y env e la garant a antes de los 15 d as posteriores de la compra El fabricante se reserva los derechos a posibles modificaciones y mejoras sobre este manual y equipo TAL al J P g 2 Manual de instrucciones 50171146 Revisi n 1 Septiembre 08 ENGLISH Lenses must not be disassembled by the user Were there any dust or dirt to be cleaned clean it with a natural horse hair brush or a smooth piece of cloth fluff free dampened with a bit of xylene or toluene To remove dust from lenses blow them with a plastic bulb or clean them with a natu ral horsehair brush Use non corrosive lubricants in metallic parts being careful of not touching optical parts NOTE Never disassemble the objective lenses DISINFECTED THEY WOULD NOT BE ALLOWED TO REPAIR BY OUR ATTENTION IF E
28. ue unless you keep a continued and careful maintenance Please follow the processes of use of this manual This manual should be available for all users of this equipment Always use original components and supplies Other devices can be similar but they can damage the equipment The microscope is supplied with a standard wire and it should be connected to a current wire provided with an earth wire it should be handy to be disconnected in case of emer gency Never try to repair the microscope by yourself since you will lose the warranty and may provoke damages to the general operating system or the electrical installation as well as injuries to the people that usually handle the microscope burns hurts or dama ges in nearby equipments In the event of breakdown please contact your distributor to overhaul through Zuzi Technical Assistance Department Centering the objectives Each objective can be centered individually in the nosepiece to align them perfectly with the light path and thus avoid images distortions For this purposes insert the supplied keys in the centering screws 1 9 placed on each side of the objective Version 1 September 08 Instruction manual 50171146 Page 2l i j ENGLISH Figure 4 41 4 4 4 2 4 5 4 7 Adjust the condenser height 4 1 depending on the objective in use The higher magni fication of the objective the clos
29. uestras bajo luz polarizada resultan do de gran aplicaci n en petrograf a mineralog a y qu mica de materiales as como en his tolog a y anatom a patol gica para la observaci n de numerosas estructuras que poseen birrefringencia estructuras cristalinas pigmentos l pidos dep sitos de amiloide etc Para ello el microscopio posee un filtro polarizador bajo la platina que transmite luz polarizada en direcci n N S y un filtro analizador situado encima de la platina que transmite s lo la luz que vibra en direcci n E O Cuando ambos polarizadores se encuen tran en posici n ortogonal situados a 90 entre s se extingue la luz generada por el pola rizador y no se observa nada sin embargo si la muestra presenta birrefringencia la estructura birrefringente se iluminar sobre un fondo oscuro Ta Manual de instrucciones 50171146 P g 3 a j Revisi n 1 Septiembre 08 CASTELLANO 2 DESCRIPCION 1 1 Cabezal binocular 1 10 Platina giratoria 1 2 Oculares 1 11 Tornillo fijaci n de la platina 1 3 Tubo intermedio 1 12 Condensador 1 4 Lente Bertrand 1 13 Polarizador 1 5 Tornillos de centrado de la lente 1 14 Precondensador Bertrand 1 15 Mando de enfoque macrom trico 1 6 Analizador 1 16 Mando de enfoque microm trico 1 7 Hendidura para placas accesorias 1 17 Interruptor encendido apagado 1 8 Rev lver 1 18 Regulador de intensidad de ilumina 1 9 Tornillos de centrado de objetivo ci n 1 1 1 17 2 3
Download Pdf Manuals
Related Search
Related Contents
Hawk CTP User Manual(1) Télécharger le manuel d`utilisation 取扱い説明はこちら guía práctica del usuario para la estufa eléctrica de terraza OSD Manual レデューサー 0.72xDGQ【7872】 システムチャート 90FL用 Samsung 1600 Вт. Пылесос c мешком для сбора пыли Samsung SC4141 Инструкция по использованию PULIBRILL AB 2017 - Construnario.com Copyright © All rights reserved.