Home
TX100E Thermostat PRODUCT INSTALLATION
Contents
1. calefacci n que no controlan su propio ventilador tales como BOMBAS DE CALOR y las unidades que solo tienen un elemento de calentamiento ELECTRICIDAD pj el ctrico resistivo como fuente de calor GAS por defecto JP1 OPCI N DE TARJETA DE CIRCUITOS B O PARA APLICACIONES DE BOMBA DE CALOR Esta configuraci n es una tapa de pl stico de cortocircuito que determina el funcionamiento de la conexi n terminal del cable de B O compartida Este puente debe permanecer instalado para que un sistema de bomba de calor pueda proporcionar calefacci n y refrigeraci n seg n sea necesario y la mayor a de las OPCI N B MM bombas de calor hoy en d a utilizan la configuraci n predeterminada 0 Los s ntomas que se producen si este ajuste no es correcto ser n calefacci n vmientras se encuentra en el modo de refrigeraci n y refrigeraci n mientras se 3y encuentra en modo de calefacci n E OPCI N 0 por defecto Cuando se ajusta en 0 predeterminado de f brica el terminal compartido B O se encender mientras que se encuentra en el modo COOL refrigeraci n y se apagar en el modo HEAT calefacci n Cuando se establece en B necesario para algunas bombas de calor Rheem Ruud y Bard el terminal compartido B O se enciende en el modo HEAT calefacci n y se apaga en el modo COOL refrigeraci n CONTROLES DEL PANEL FRONTAL INTERRUPTOR DE MODO DEL SISTEMA HEAT OF
2. 4 L mite de 60 F 16 C La temperatura de ajuste de calefacci n m xima es de 60 F 16 C ELEMENTO N 05 L MITE DE TEMPERATURA DE AJUSTE DE REFRIGERACI N M NIMA 1 por defecto L mite de 45 F 7 C La temperatura de ajuste de refrigeraci n m nima es de 45 F 7 C sin restricciones de temperatura en modo de refrigeraci n 2 L mite de 55 F 13 C La temperatura de ajuste de refrigeraci n m nima es de 55 F 13 C 3 L mite de 65 F 18 C La temperatura de ajuste de refrigeraci n m nima es de 65 F 18 C 4 L mite de 75 F 24 C La temperatura de ajuste de refrigeraci n m xima es de 75 F 24 C ELEMENTO N 06 TIPO DE SISTEMA EQUIPO 1 por defecto Fn estufa Esto es para la mayor a de los sistemas de calefacci n como una estufa o caldera de agua caliente a gas natural que no son sistemas de bombas de calor 2 HP bomba de calor Use este ajuste si tiene un sistema de bomba de calor que utiliza la unidad exterior como la fuente primaria de calor La presencia de un cable 0 o B en su termostato anterior por lo general indica que tiene un sistema de bomba de calor Este termostato NO es compatible con bombas de calor que tambi n tienen una resistencia el ctrica como fuente de calor de respaldo llamada calefacci n auxiliar de emergencia IMPORTANTE Cuando se establece en 2 para HP la opci n Gas Electric gas electricidad de la placa de circuito tambi
3. suministrado DE BOMBA DE CALOR VALVULA DE INVERSI N Bomba de calor si 0 y B est n presentes instale el cable anterior B en el terminal C NOTA LAS LETRAS NEGRAS DE TERMINALES SON CONVENCIONALES LAS LETRAS GRISES DE TERMINALES SON ESPEC FICAS DE CADA MARCA NOTA LAS LETRAS NEGRAS DE TERMINALES SON CONVENCIONALES LAS LETRAS GRISES DE TERMINALES SON ESPEC FICAS DE CADA MARCA NOTE THE BLACK TERMINAL LETTERS ARE TYPICAL GRAY TERMINAL LETTERS ARE BRAND SPECIFIC 4 5 6 WIRES CONVENTIONAL NON HEAT PUMP 1 HEAT 1 COOL WITH TWO TRANSFORMERS OPTIONAL SYSTEM COMMON H Qu Ec nal QR a JH REMOVE Factory RH RC Jumper Wire NOTE THE BLACK TERMINAL LETTERS ARE TYPICAL GRAY TERMINAL LETTERS ARE BRAND SPECIFIC NOTE THE BLACK TERMINAL LETTERS ARE TYPICAL GRAY TERMINAL LETTERS ARE BRAND SPECIFIC 3 4 5 WIRES HEAT PUMP SYSTEMS 1 HEAT 1 COOL ONLY WITH NO AUXILIARY EMERG HEAT OPTIONAL SYSTEM COMMON col BM A 1 ca anana 24V TRANSFORMER Factory RH RC Jumper Wire Installed For Heat Pumps ONLY Add Second Jumper Wire Supplied NOTE THE BLACK TERMINAL LETTERS ARE TYPICAL GRAY TERMINAL LETTERS ARE BRAND SPECIFIC Heat Pump if 0 and B are both present install old B wire onto C terminal 53574 53572 2 3 4 CABLES 2 3 4 CABLES 3 4 5 CABLES 2 3 4 WIRES 2 3 4 W
4. COOL refrigeraci n que est n en el interruptor System Mode Modos del sistema y empleando UP arriba o DOWN abajo para ajustar la temperatura Para mantener una nica temperatura fija puede utilizar el bot n HOLD mantener Si hay un candado en la pantalla de visualizaci n la funci n de bloqueo del teclado num rico est activada ambos interruptores deslizantes de modo todav a funcionan NOTAS DEL DIAGRAMA DEL CABLEADO 1 Si los diagramas de cableado no representan o no coincide claramente con su sistema por favor consulte la secci n ASISTENCIA TECNICA a continuaci n y comun quese con nosotros antes de retirar cualquier cable de su termostato actual 2 Todos los cables marcados con L NEAS PUNTEADAS que se muestran en los diagramas de cableado son opcionales o su uso depende del tipo de su sistema espec fico EJEMPLO El diagrama N 1 muestra el cable del ventilador como opcional Esto no infiere que su sistema no tiene un ventilador solo que es posible que no haya un cable para este 3 Las letras de los terminales que se muestran en negro representan el uso de cableado t pico Las letras de los terminales que se muestran en gris representan otras posibles designaciones en el cableado que podr a observar en la marca y modelo espec fico de su termostato 4 El terminal C opcional se usa para proporcionar alimentaci n el ctrica al termostato por medio del sistema de 24 voltios proporcionado por su sistem
5. System Mode switch and press the following four button sequence NEXT NEXT NEXT HOLD TEMPERATURE PROGRAMMING By default this thermostat has 4 separate program periods for both Heat and Cool modes they are MORN DAY EVE and NITE Each period ends at the start time of the next upcoming period The Heat temperature programs are set while the mode switch is in the HEAT position and the Cool temperature programs are set while the mode switch is in COOL NOTE If the thermostat is configured to use only 2 periods per day instead of the factory default of 4 periods per day the thermostat will only use the DAY and NITE period designations The MORN and EVE periods will not be used or visible on the screen TO SET A TEMPERATURE PROGRAM Choose either HEAT or COOL mode and press the SET button Programming will start with PROG position Use UP or DOWN to adjust the start time for the first period and then press the NEXT button to advance Use UP or DOWN to adjust the set temperature for the first period and then press the NEXT button to advance Now adjust the start time and set temperature for the second period pressing NEXT after each item to advance Continue with these same steps to adjust the start times and set temperatures for the third and fourth periods if present When the last period is finished for each day or group of days the thermostat will advance forward into the next day or group of days When you are complete
6. extremos desnudos de los cables se mantengan COMPLETAMENTE en el bloque de terminales mientras que el tornillo se aprieta y tenga cuidado de no apretarlos demasiado ya que solo tienen que estar bien ajustados COMPLETE LA INSTALACI N OPCI N DE TARJETA DE CIRCUITOS GAS ELEC FUNCIONAMIENTO DEL VENTILADOR DEL TERMINAL G Esta opci n es una tapa de cortocircuito de pl stico llamada puente Este puente debe permanecer instalado y configurado a GAS o ELECTRIC electricidad para que el sistema funcione correctamente Esta configuraci n cambia la forma en la cual se controla el ventilador de su sistema si es aplicable mientras que el termostato est en modo HEAT calefacci n y el interruptor del ventilador est en la posici n AUTO autom tico Este ajuste no afecta el funcionamiento del ventilador mientras que el termostato est en el modo COOL refrigeraci n Cuando se establece en GAS nicamente el sistema de calefacci n controla el ventilador Los sistemas que usar an habitualmente la configuraci n GAS ser an estufas y calderas a gas natural propano o petr leo NOTA Si su ventilador no funciona adecuadamente despu s de la instalaci n cambie la opci n de gas o electricidad a la posici n de ajuste de Electric Cuando se establece en ELEC el ventilador est controlado directamente por el termostato Esta configuraci n es necesaria para los sistemas de Aa al ELEC Bl
7. whenever you see the LO BATT indication on the screen Failure to follow these battery instructions could result in property damage and or personal injury The electrical rating for this thermostat is 1 5 Amps per terminal with a maximum total load of 2 04 for all terminals combined The thermostat contains parts that may wear out through use and are susceptible to failure if over loaded or used in a manner other than as indicated in the documentation Check unoccupied residences regularly to ensure that all systems are operating properly Check any heating air conditioning system including this product before operation and at regular intervals Electrical interference static electricity failure or substandard performance of batteries wiring defects in the installation and or characteristics of the connected HVAC devices may prevent the system from regulating heating and cooling as anticipated The thermostat is a sensitive device and dropping the product can cause damage to critical components If the product is dropped or shaken violently during transport or installation then it should be replaced immediately Persons with physical or mental limitations may not be able to promptly respond to a malfunction of the heating air conditioning system All residents should be made aware of the potential in any system for malfunctions that could cause continuous heating or cooling and should be familiar with the operation and location of the
8. F COOL CALEFACCI N APAGADO REFRIGERACI N Ponga el interruptor en HEAT calefacci n para controlar su sistema de calefacci n y en COOL refrigeraci n para controlar su sistema de refrigeraci n La posici n de OFF apagado desactivar las unidades de calefacci n y de refrigeraci n INTERRUPTOR DE MODOS DEL VENTILADOR AUTO ON AUTOM TICO ENCENDIDO Cuando este interruptor est en AUTO autom tico el ventilador de existir en su sistema se encender y apagar autom ticamente mientras funcionen la calefacci n o la refrigeraci n Cuando el interruptor est en la posici n de ON encendido el ventilador funcionar constantemente en todo momento con o sin demanda de calefacci n o el refrigeraci n BOT N SET CONFIGURACI N Este bot n se utiliza para acceder a la configuraci n del programa de temperatura cuando se encuentra en modo de calefacci n o refrigeraci n y para ajustar el d a y el reloj en el modo de apagado BOT N NEXT SIGUIENTE Este bot n se usa mientras se configuran elementos tales como opciones del software y programas de temperatura Cuando los elementos de la pantalla parpadean durante los ajustes pulsar el bot n de NEXT siguiente permitir cambiar el elemento que est parpadeando BOT N HOLD MANTENIMIENTO Este bot n activa y desactiva la funci n Mantenimiento de temperatura manual que mantiene una temperatura de consigna fija de manera indefinida sin seguir la rutina de un programa Es
9. IRES 3 4 5 WIRES CONVENCIONAL SIN BOMBA DE CALOR CONVENCIONAL SIN BOMBA DE CALOR CONVENCIONAL SIN BOMBA DE CALOR CONVENTIONAL NON HEAT PUMP CONVENTIONAL NON HEAT PUMP CONVENTIONAL NON HEAT PUMP 1 ETAPA CALEFACCION SOLAMENTE 1 ETAPA REFRIGERACI N SOLAMENTE CALEFACCI N DE 1 ETAPA Y REFRIGERACI N DE 1 ETAPA 1 STAGE HEAT ONLY 1 STAGE COOL ONLY 1 STAGE HEAT AND 1 STAGE COOL INCLUIDO MILIVOLTIO INCLUDING MILLIVOLT ON CABLE COM N DEL SISTEMA N 22 CABLE COM N DEL SISTEMA CABLE COM N DEL SISTEMA o OPTIONAL 2 OPTIONAL OPTIONAL Q X OPCIONAL Q X OPCIONAL Q X OPCIONAL Q X SYSTEM COMMON a X SYSTEM COMMON a X SYSTEM COMMON C Qs RON H Qu ONO AAA H Qu ONE AAA H Qu 1 CORA 6 Qs CONAN H Qu CONAM so UE vemiavos bo E veranos so SUE vemiavos JH so QR a JH io QR a JH QR a JH de puente RAM de puente de puente PE RA R RE RURE RH RC CALEFACCI N DE 24V RH RC RH RC Jumper TRANSFORMER Jumper Jumper TRANSFORMER instalado instalado instalado Wire Wire Wire de f brica de f brica R AT de f brica Installed Installed RA Installed REFRIGERACI N DE 24V TRANSFORMER A caeno naa O CALENTADOR HEATER LO Y1 6 Le Yi 6 NOTE THE BLACK TERMINAL LETTERS ARE TYPICAL GRAY TERMINAL LETTERS ARE BRAND SPECIFIC
10. PRODUCT INSTALLATION MANUAL 53572 TX100E Thermostat 7 Day or 5 2 Day Programmable or Non Programmable Lux Products Corporation Mt Laurel New Jersey 08054 http www luxproducts com WARNING Use Energizer or DURACELL Alkaline Batteries Only Energizer is a registered trademark of Eveready Battery Company Inc DURACELL is a registered trademark of The Procter amp Gamble Company IMPORTANT e Label every wire terminal designation on your existing thermostat wiring before removing your old thermostat e Ignore the color of the wires since they may not comply with any standard Please connect wires using the terminal letter designations SYSTEM COMPATIBILITY This thermostat can be used with most 24 volt gas oil Millivolt electric heating and cooling systems including single stage heat pumps WITHOUT auxiliary or emergency heat element It cannot be used with 120 240 volt heating elements without a transformer or on heat pump systems that have more than one heating or cooling stage Ask your dealer for other LUX thermostats to control those systems CAUTIONS AND WARNINGS e The thermostat requires batteries to operate and failure or sub standard performance of the batteries may impair or prevent the correct operation of the thermostat Use Duracell or Energizer alkaline batteries ONLY for all LUX thermostats requiring batteries BE SURE TO CHANGE THE BATTERIES AT LEAST ONCE A YEAR or
11. S Y ADVERTENCIAS e El termostato requiere bater as para funcionar y la falla o el rendimiento deficiente de las bater as puede afectar o impedir el correcto funcionamiento del termostato Use SOLO bater as alcalinas Energizer o Duracell para todos los termostatos LUX que requieran bater as ASEG RESE DE CAMBIAR LAS BATER AS AL MENOS UNA VEZ AL A O o cada vez que vea la indicaci n LO BATT bater a baja en la pantalla No seguir correctamente las instrucciones de las bater as puede resultar en da os personales y o materiales La especificaci n el ctrica para este termostato es de 1 5 A por terminal con una carga m xima total de 2 0 A para todas las terminales combinadas El termostato contiene partes que pueden deteriorarse por medio de su uso y que son propensas a fallar si se las sobrecarga o si se las usa de manera diferente a la indicada en la documentaci n Revise regularmente las residencias desocupadas para asegurarse de que todos los sistemas est n funcionando correctamente Revise cualquier sistema de climatizaci n incluido este producto antes de ponerlo en funcionamiento y en intervalos peri dicos La interferencia el ctrica la electricidad est tica la falla o rendimiento deficiente de las bater as defectos de cableado en la instalaci n y o caracter sticas de los dispositivos de calefacci n ventilaci n y aire acondicionado que est n conectados pueden impedir que el sistema regule la calefacci n y la refri
12. When complete press the NEXT button to return to the normal operating screen O 2014 LUX PRODUCTS CORPORATION ALL RIGHTS RESERVED MANUAL DE INSTALACI N DEL PRODUCTO 53574 Termostato TX100E Programable para 7 d as o 5 2 d as o no programable Lux Products Corporation Mt Laurel New Jersey 08054 http www luxproducts com ADVERTENCIA Utilice solo bater as alcalinas Energizer o DURACELL Energizer es una marca registrada de Eveready Battery Company Inc DURACELL es una marca registrada de The Procter amp Gamble Company IMPORTANTE e Ponga una etiqueta para designar cada una de los terminales del cableado del termostato actual antes de retirar el termostato que se ha de reemplazar e No haga caso a los colores de los cables ya que es posible que no cumplan con ninguna norma Conecte los cables usando las designaciones por letras para los terminales COMPATIBILIDAD DEL SISTEMA Este termostato se puede utilizar con la mayor a de los sistemas de calefacci n y refrigeraci n el ctricos de 24 voltios a gas petr leo o milivoltios incluidas las bombas de calor de una sola etapa SIN resistencia auxiliar o de emergencia No se puede utilizar con resistencias de 120 240 voltios sin un transformador o en sistemas de bomba de calor que tienen m s de una etapa de refrigeraci n o calefacci n Consulte a su distribuidor sobre otros termostatos LUX para controlar esos sistemas PRECAUCIONE
13. a de climatizaci n mediante el cable com n del sistema Este se puede usar solo o adem s de la instalaci n de bater as a modo de respaldo NOTA al emplear bater as la conexi n del cable com n del sistema al termostato no es necesaria para que la calefacci n y la refrigeraci n funcionen correctamente 5 Si el termostato anterior tiene TANTO un cable 0 y B presentes entonces es probable que B sea un cable com n del sistema cable de alimentaci n y puede conectarse al terminal C o encintarse y no usarse Conectar un cable com n del sistema al terminal B O de este termostato puede da ar el termostato e incluso el equipo que integra su sistema de calefacci n y refrigeraci n 6 Si las conexiones de su termostato existentes contienen un cable etiquetado como W2 AUX E o X2 esto indicar a que tiene etapas de calefacci n adicionales presentes Este es un termostato de una sola etapa y no puede adaptarse a ninguno de estos componentes del sistema Usted tendr que seleccionar un modelo diferente 7 Si est remplazando un termostato que cuenta con un reloj mec nico en el panel delantero puede haber DOS cables marcados como C para la alimentaci n del reloj No conecte ninguno de los dos a este termostato ASISTENCIA T CNICA Si tiene alg n problema para instalar o usar este termostato lea con cuidado y detenimiento el manual de instrucciones Si a n as necesita as
14. a de los casos no deber a ser necesario modificar este ajuste CONFIGURAR D A Y HORA Mueva el interruptor System Mode modos del sistema a la posici n OFF apagado y pulse el bot n SET configurar una vez El d a en la parte superior de la pantalla deber a comenzar a parpadear con lo cual se puede ajustar utilizando las teclas UP arriba o DOWN abajo Pulse el bot n NEXT siguiente y la hora del reloj deber a empezar a parpadear con lo cual se puede ajustar utilizando las teclas UP arriba o DOWN abajo Aseg rese de que la indicaci n AM PM que se muestra sea correcta y mantener presionados los botones UP arriba o DOWN abajo har que los d gitos del reloj se desplacen r pidamente Cuando termine pulse el bot n NEXT siguiente para volver a la pantalla de funcionamiento normal O 2014 LUX PRODUCTS CORPORATION TODOS LOS DERECHOS RESERVADOS DESCARGUE EL MANUAL DE INSTRUCCI N COMPLETO DE NUESTRO SITIO WEB Esta hoja contiene las instrucciones b sicas de instalaci n y configuraci n Hay otros temas que se tratan con mayor detalle en la versi n completa del manual para este termostato El manual completo en PDF se puede descargar en http www luxproducts com Haga clic en SUPPORT asistencia y luego en INSTRUCTION MANUALS manuales de instrucciones Muchos modelos de termostatos tienen letras de revisi n en min scula despu s del nombre del modelo por ejemplo TX1500Ua Por favor elija el manual que coin
15. cida exactamente con el n mero de modelo que aparece en su termostato en particular BLOQUEO DEL TECLADO Los botones del panel delantero se pueden bloquear para evitar la manipulaci n no autorizada de la temperatura de ajuste y otros par metros Ni el interruptor System Mode modos del sistema o Fan Mode modos del ventilador se bloquean y cuando el bloqueo del teclado num rico est activo habr un icono de candado que se muestra en la pantalla Para bloquear o desbloquear los botones del teclado num rico seleccione HEAT calefacci n o COOL refrigeraci n en el interruptor System Mode modos del sistema y pulse la siguiente secuencia de cuatro botones NEXT NEXT NEXT HOLD PROGRAMACI N DE TEMPERATURA En forma predeterminada este termostato tiene 4 per odos de programas distintos tanto para el modo Heat calefacci n como para el modo Cool refrigeraci n MORN DAY EVE y NITE MANANA D A TARDE y NOCHE Cada periodo termina a la hora en que comienza el siguiente Los programas de temperatura de calefacci n se establecen cuando el selector de modos est en la posici n HEAT y los programas de temperatura de refrigeraci n se establecen cuando el selector de modo est en COOL NOTA Si el termostato est configurado para usar solo 2 per odos por d a en lugar del valor predeterminado de f brica de 4 per odos por d a el termostato nicamente usar las designaciones de per odo DAY d a y NITE noche L
16. e and install the mounting screws If the previous holes cannot be used hold the thermostat base against the wall so that it appears straight and level position the base for best appearance and mark for the new screw holes Attach the base to the wall using the screws provided use the supplied plastic anchors if needed when mounting to a soft material such as drywall When attaching the wires to the thermostat please ensure that the bare wire ends are held ALL the way into the terminal block while the screw is being tightened and be careful not to over tighten them as they only need to be snug COMPLETE THE INSTALL GAS ELEC CIRCUIT BOARD OPTION G TERMINAL FAN OPERATION This setting is a plastic shorting cap called a jumper This jumper must remain installed and set to either GAS or ELECTRIC for your system to work properly This setting changes how your system s blower fan if applicable is controlled while the thermostat is in HEAT mode and the Fan switch is in the AUTO position This setting does not affect the fan operation while the thermostat is in COOL mode mM a al When set to GAS the blower fan is controlled solely by the heating system itself Systems that would typically use the GAS setting would be natural gas propane or oil furnaces and boilers NOTE If your blower fan does not operate properly after installation try moving the Gas Electric option to the Electric sett
17. eating set temperature is 70F 21C degrees 4 Limit 60F 16C The maximum heating set temperature is 60F 16C degrees ITEM 05 MINIMUM COOL SET TEMP LIMIT 1 default Limit 45F 7C The minimum cooling set temperature is 45F 7C degrees with no cool mode temperature restrictions 2 Limit 55F 13C The maximum cooling set temperature is 55F 13C degrees 3 Limit 65F 18C The maximum cooling set temperature is 65F 18C degrees 4 Limit 75F 24C The maximum cooling set temperature is 75F 24C degrees ITEM 06 SYSTEM EQUIPMENT TYPE 1 default Fn Furnace This is for the majority of heating systems such as a natural gas furnace or hot water boiler that are not Heat Pump systems 2 HP Heat Pump Use this setting if you have a Heat Pump system which uses the outdoor unit as the primary heat source The presence of either an 0 or B wire on your previous thermostat would typically indicate you have a heat pump system This thermostat is NOT compatible with heat pumps which also have an electric heating element as a backup heat source called Auxiliary Emergency Heat IMPORTANT When set to 2 for HP the circuit board Gas Electric option must also be set to ELEC as described earlier in the COMPLETE THE INSTALL section ITEM 07 DELAY TIME 1 default 5 Minutes Thermostat waits 5 minutes before turning the system back on after it was last run The 5 minute setting is fine fo
18. elos de manera que no caigan nuevamente dentro de la pared No permita que los extremos desnudos de los cables se toquen entre s INSTALACI N DEL TERMOSTATO NUEVO Utilice los diagramas de cableado que se muestran en la parte posterior de esta hoja de instalaci n para encontrar la correspondencia m s cercana a su sistema de calefacci n y o refrigeraci n en particular Lea TODAS las notas del diagrama de cableado que se muestran por encima de los esquemas de conexi n para evitar causar da os a su sistema o al nuevo termostato VD N s 1 Pele el aislamiento del cable dejando solo extremos de cable pelado de 3 8 de pulgada 9 5 mm en los extremos y limpie la corrosi n visible 2 Rellene la abertura de la pared con un aislante no inflamable para evitar que las corrientes afecten el funcionamiento normal del termostato Pase los cables a trav s de la abertura de la placa base del termostato nuevo e instale los tornillos de montaje Si no pueden utilizarse los agujeros previos mantenga la base del termostato contra la pared derecha y nivelada coloque la base de la manera que luzca mejor y marque el lugar donde deber n hacerse los nuevos agujeros para los tornillos Sujete la base a la pared con los tornillos incluidos utilice los anclajes de pl stico provistos de ser necesario cuando instale el termostato en un material blando como por ejemplo paneles de yeso Al conectar los cables al termostato aseg rese de que los
19. geraci n como estaba previsto El termostato es un dispositivo sensible y dejar caer el producto puede da ar componentes cruciales Si deja caer el producto o si lo agita violentamente durante el transporte o instalaci n deber a reemplazarse inmediatamente Personas con limitaciones f sicas o mentales pueden no ser capaces de responder r pidamente al mal funcionamiento del sistema de climatizaci n Todos los residentes deben ser conscientes de la posibilidad del mal funcionamiento en cualquier sistema que podr a generar la calefacci n o refrigeraci n continua y deben estar familiarizados con la operaci n y ubicaci n del interruptor on off encendido apagado del aparato de climatizaci n Lea el manual de instrucciones por completo antes de instalar el termostato Un manual de producto m s detallado se encuentra disponible en nuestro sitio web www luxproducts com Si no comprende las instrucciones de instalaci n en su totalidad consulte a un t cnico de climatizaci n calificado o a un electricista RETIRO DEL TERMOSTATO VIEJO Desconecte la electricidad de todos los componentes de calefacci n y refrigeraci n No la conecte hasta que el trabajo haya finalizado Anote las letras impresas cerca de cada terminal del cable que se utilice y tambi n el color de cada uno de los cables que est n conectados al terminal Tambi n se incluyen etiquetas autoadhesivas para cables Retire cuidadosamente los cables uno a uno y d bl
20. heating cooling appliance on off switch Read the instruction manual completely before installing the thermostat A more detailed product manual is available on our www luxproducts com website You should consult a qualified HVAC technician or an electrician if you do not fully understand the installation instructions REMOVAL OF OLD THERMOSTAT Turn OFF the electricity to all heating and cooling components Do not turn the electricity back on until all work is completed Write down the letters printed near each wire terminal that is used and also the color of each wire that is connected to it Self adhesive wire labels are also enclosed Carefully remove the wires one at a time and bend them in a manner so that they do not fall back inside the wall Do not allow bare wire ends to touch each other INSTALLATION OF NEW THERMOSTAT Use the wiring diagrams shown on the back of this installation sheet to find the closest match to your particular heating and or cooling system Please read ALL of the Wiring Diagram Notes that are shown above the connection diagrams to avoid causing damage to your system or the new thermostat N 90 1 Strip wire insulation leaving only 3 8 in 9 5mm bare wire ends and clean off any corrosion present Fill the wall opening with non combustible insulation to prevent drafts from affecting the thermostat s normal operation Route the wires through the opening in the new thermostat base plat
21. ing ELEC O When set to ELEC the blower fan is controlled directly by the JP1 thermostat This setting is required for heating systems that do not control their own fan such as HEAT PUMPS and units that only have an GAS electric resistive heating element as the heat source default JP1 B O CIRCUIT BOARD OPTION FOR HEAT PUMP APPLICATIONS This setting is a plastic shorting cap which determines the operation of the B OPTION shared B O wire terminal connection This jumper must remain installed for a Heat Pump system to be able to provide heating and cooling as 30 JP2 needed and the majority of heat pumps today use the default 0 setting The symptoms that will occur if this setting is not correct will be heating while in cool mode and cooling while in heat mode 3 JP2 When this is set to 0 factory default the shared B O terminal will be MM turned on while in COOL mode and off in HEAT mode 0 OPTION When this is set to B which is needed for some Rheem Ruud and default Bard heat pumps the shared B O terminal will be turned on in HEAT mode and off in COOL mode FRONT PANEL CONTROLS HEAT OFF COOL SYSTEM MODE SWITCH Set this switch to HEAT to control your heating system and COOL to control your cooling system The OFF position will disable both the heating and cooling units AUTO ON FAN MODE SWITCH When in AUTO the blower fan if present in y
22. istencia t cnica comun quese con nuestro departamento de Asistencia T cnica al 856 234 8803 en el horario normal de oficina de 8 00 a m a 4 30 p m hora del este de lunes a viernes Tambi n puede recibir asistencia t cnica a cualquier hora del d a y la noche en http www luxproducts com Nuestro sitio Web ofrece gu as para resolver problemas respuestas a las preguntas t cnicas m s frecuentes y tambi n le permite enviar sus preguntas por correo electr nico a nuestro personal de asistencia t cnica seg n su propia conveniencia DOWNLOAD FULL INSTRUCTION MANUAL FROM OUR WEBSITE This sheet contains basic installation and setup instructions There are additional topics covered in greater detail in the full version of the manual for this thermostat The full PDF manual can be downloaded at http www luxproducts com Click on SUPPORT then INSTRUCTION MANUALS Many thermostat models have lower case revision letters after the model name i e TX1500Ua Please choose the manual that exactly matches the model number shown on your particular thermostat KEYPAD LOCKOUT The front panel buttons can be locked out to prevent unauthorized tampering of the set temperature and other settings Neither the System Mode or Fan Mode slide switches are locked out and when the Keypad Lockout is active there will be a padlock icon shown in the display screen To lock or unlock the keypad buttons first select either HEAT or COOL on the
23. n se debe establecer en ELEC como se describe anteriormente en la secci n Realizaci n de la instalaci n ELEMENTO N 07 TIEMPO DE RETARDO 1 por defecto 5 minutos El termostato espera 5 minutos antes de encender el sistema de nuevo despu s de que lo oper por ltima vez El ajuste de 5 minutos es correcto para la mayor a de aplicaciones y ofrece la protecci n del equipo mediante la prevenci n de ciclos r pidos 2 Es la misma operaci n que el anterior pero reducida a 2 minutos entre cambios de estado si lo desea ELEMENTO N 08 CAMBIO DE TEMPERATURA 1 por defecto Este es el control m s ajustado que es m s menos 0 259F 0 14 C con respecto a la temperatura de ajuste objetivo 2 a 9 Estos valores alternativos hacen que el control de temperatura sea m s amplio con m s variaci n Cada n mero de ajuste de aumento gradual a ade 0 25 F 0 14 F adicionales a la configuraci n inicial 9 es el ajuste de control m s amplio que es m s menos 2 25 F 1 25 C grados de la temperatura de ajuste ELEMENTO N 09 CALIBRACI N DE TEMPERATURA 0 cero por defecto En cero no hay cambios en la medici n de la temperatura ambiente de base El ajuste es desde un nivel que se determina restando 5 F 3 C a la temperatura ambiente a un nivel que se determina sumando 5 F 3 C a la temperatura ambiente El sensor de temperatura interna se calibra con precisi n en la f brica y en la mayor
24. os per odos MORN ma ana y EVE tarde no se usar ni se ver n en la pantalla PARA DEFINIR UN PROGRAMA DE TEMPERATURA Elija el modo HEAT calefacci n o COOL refrigeraci n y pulse el bot n SET configurar La programaci n se iniciar con la posici n PROG Use UP arriba o DOWN abajo para ajustar la hora de inicio del primer per odo y luego presione el bot n NEXT siguiente para avanzar Use UP arriba o DOWN abajo para ajustar la temperatura para el primer per odo y luego presione el bot n NEXT siguiente para avanzar Ahora ajuste la hora de inicio y la temperatura para el segundo periodo presione NEXT luego de cada elemento para continuar Repita estos mismos pasos para ajustar las horas de inicio y establecer temperaturas para el tercer y cuarto per odos si est n presentes Cuando el ltimo per odo termin para cada d a o grupo de d as el termostato avanzar al siguiente d a o grupo de d as Cuando haya finalizado puede pulsar el bot n SET configurar para guardar los cambios y volver al modo de funcionamiento normal NOTA Si no se desea una rutina de programa de temperatura es posible cambiar el ELEMENTO N 02 en las Setup Options opciones de configuraci n a 3 para el modo manual no programable CALEFACCI N B SICA Y OPERACI N DE ENFRIAMIENTO El funcionamiento b sico de su sistema de calefacci n o refrigeraci n se puede activar mediante la selecci n de HEAT calefacci n o
25. our system will cycle on and off only while heating or cooling In the ON position the blower fan will run constantly at all times with or without a demand for heating or cooling SET BUTTON This button is used to access the temperature program settings when in heat or cool mode and for adjusting the day and clock while in off mode NEXT BUTTON This is used when setting items such as software options and temperature programs When items on the screen are flashing during adjustments pressing the NEXT button will cycle through which item is flashing HOLD BUTTON This button activates and deactivates the manual Temperature Hold feature which maintains a fixed set temperature indefinitely without following a program routine This button is not used when ITEM 02 below is set to 3 for manual non programmable UP DOWN BUTTONS The UP and DOWN buttons are used to control the set temperature or adjust any other on screen items Typically an item that is flashing can currently be adjusted SYSTEM CONFIGURATION AND SETUP OPTIONS INSTALL BATTERIES INTO THERMOSTAT Install two brand new Energizer or DURACELL AA size alkaline only batteries into the thermostat s battery compartment Ensure the batteries are installed in the proper direction Setup options for how the thermostat will function along with choosing your particular system type are performed using a menu on the display screen TO ACCESS THE SETUP MENU Move
26. r most applications and provides equipment protection by preventing rapid cycling 2 Same operation as above but reduced to 2 minutes between state changes if desired ITEM 08 TEMPERATURE SWING 1 default This is the tightest control which is plus minus 0 25F 0 14C degrees from the target set temperature 2 through 9 These alternate values make the temperature control wider with more variation Each incremental setting number adds an additional 0 25F 0 14F degrees onto the initial setting 9 is the widest control setting which is plus minus 2 25F 1 25C degrees from the set temperature ITEM 09 TEMPERATURE CALIBRATION 0 zero default At zero there are no changes made to the base room temperature measurement The adjustment is from as low as subtracting 5F 3C degrees from the room temperature to as high as adding 5F 3C degrees to the room temperature The internal temperature sensor is accurately calibrated at the factory and in most cases this setting should not need to be altered SET DAY AND TIME Move the System Mode switch into the OFF position and press the SET button once The Day on the top of the display should begin flashing which can be adjusted using UP or DOWN Press the NEXT button and the clock time should start flashing which can be adjusted using UP or DOWN Make sure the AM PM indication shown is correct and holding the UP or DOWN buttons will make the clock digits scroll rapidly
27. rn Time Monday through Friday You can also receive technical assistance online anytime day or night at http www luxproducts com Our website offers you troubleshooting guides answers to the most common technical questions and also permits you to email your questions to our technical support staff at your convenience NOTA LAS LETRAS NEGRAS DE TERMINALES SON CONVENCIONALES LAS LETRAS GRISES DE TERMINALES SON ESPEC FICAS DE CADA MARCA 4 5 6 CABLES CONVENCIONAL SIN BOMBA DE CALOR CALEFACCI N DE 1 ETAPA Y REFRIGERACI N DE 1 ETAPA CON DOS TRANSFORMADORES CABLE COM N DEL SISTEMA OPCIONAL H u Eoc A F QQ VENTILADOR RETIRE Cable de TRANSFORMADOR DE puente CALEFACCI N DE 24V RH RC de f brica TRANSFORMADOR DE REFRIGERACI N DE 24V CALENTADOR UNIDAD DE A C NOTA LAS LETRAS NEGRAS DE TERMINALES SON CONVENCIONALES LAS LETRAS GRISES DE TERMINALES SON ESPEC FICAS DE CADA MARCA UNIDAD DE A C NOTA LAS LETRAS NEGRAS DE TERMINALES SON CONVENCIONALES LAS LETRAS GRISES DE TERMINALES SON ESPEC FICAS DE CADA MARCA 3 4 5 CABLES SISTEMAS DE BOMBAS DE CALOR CALEFACCI N DE 1 ETAPA Y REFRIGERACI N DE 1 ETAPA SOLAMENTE SIN CALEFACCI N AUXILIAR DE EMERGENCIA CABLE COM N DEL SISTEMA OPCIONAL E A A F DOE VENTILADOR Cable de puente RH RC instalado de f brica TRANSFORMADOR DE 24V Para bombas de calor SOLAMENTE A adir segundo cable puente
28. s Fahrenheit 2 Muestra todos los valores de temperatura en grados Celsius ELEMENTO N 02 ESTILO DE PROGRAMACI N 1 por defecto Programaci n de 5 2 d as Este estilo utiliza una rutina de programa de d as de semana para el lunes martes mi rcoles jueves viernes y una rutina de programa de fin de semana por separado para el s bado y el domingo 2 Programaci n de 7 d as Este estilo utiliza una rutina de programa separado para cada uno de los 7 d as de la semana 3 Manual no programable En esta configuraci n no hay rutinas de programa para que el termostato siga y el control de temperatura se configurar nicamente mediante los botones UP arriba y DOWN abajo del panel delantero ELEMENTO N 03 CANTIDAD DE PER ODOS E 1 por defecto 4 per odos El termostato utiliza cuatro periodos por d a llamados MORN MANANA DAY D A EVE TARDE y NITE NOCHE 2 2 per odos El termostato utiliza solamente dos periodos por d a llamados DAY D A y NITE NOCHE ELEMENTO N 04 L MITE DE TEMPERATURA DE AJUSTE DE CALEFACCI N M XIMA 1 por defecto L mite de 90 F 32 C La temperatura de ajuste de calefacci n m xima es de 90 F 32 C sin restricciones de temperatura en modo de calefacci n 2 L mite de 80 F 27 C La temperatura de ajuste de calefacci n m xima es de 80 F 27 C 3 L mite de 70 F 21 C La temperatura de ajuste de calefacci n m xima es de 70 F 21 C
29. te bot n no se utiliza cuando el ELEMENTO N 02 a continuaci n se establece en 3 para la configuraci n manual no programable BOTONES UP DOWN ARRIBA ABAJO Los botones UP arriba y DOWN abajo se utilizan para controlar la temperatura del sistema o ajustar otros elementos que aparecen en pantalla Por lo general un elemento que est parpadeando se puede ajustar ahora CONFIGURACI N DEL SISTEMA Y OPCIONES DE CONFIGURACI N INSTALAR LAS BATER AS EN EL TERMOSTATO Instale dos bater as alcalinas solamente nuevas Energizer o DURACELL tama o AA en el compartimiento para las bater as del termostato Aseg rese de que las bater as est n instaladas en la direcci n correcta Las opciones de configuraci n para c mo funcionar el termostato junto con la elecci n de su tipo de sistema particular se realizan mediante un men en la pantalla de visualizaci n PARA ACCEDER AL MEN SETUP CONFIGURACI N Mueva el interruptor System Mode modos del sistema a la posici n OFF apagado y luego mantenga pulsado el bot n SET configurar durante aproximadamente 5 segundos hasta que la pantalla cambie El men siempre comenzar con el elemento N 01 y avanza a cada punto siguiente al presionar sola vez el bot n NEXT siguiente Las opciones de cada elemento cambian con los botones UP arriba o DOWN abajo ELEMENTO N 01 ESCALA DE TEMPERATURA 1 por defecto Muestra todos los valores de temperatura en grado
30. the System Mode switch into the OFF position and then hold down the SET button for approximately 5 seconds until the screen changes The menu will always start with item 01 and is advanced to each following item by a single press of the NEXT button The options for each item are changed using the UP or DOWN buttons ITEM 01 TEMPERATURE SCALE 1 default Shows all temperature values in Fahrenheit 2 Shows all temperature values in Celsius ITEM 02 PROGRAMMING STYLE 1 default 5 2 Day Programming This style uses a weekday program routine for Monday Tuesday Wednesday Thursday Friday and a separate weekend program routine for Saturday and Sunday 2 7 Day Programming This style uses a separate program routine for each of the 7 days in the week 3 Manual Non Programmable In this setting there are no program routines for the thermostat to follow and the temperature control will be set only by the UP and DOWN buttons on the front panel ITEM 03 PERIOD QUANTITY 1 default 4 Periods Thermostat uses four periods per day called MORN DAY EVE and NITE 2 2 Periods The thermostat uses only two periods per day called DAY and NITE ITEM 04 MAXIMUM HEAT SET TEMP LIMIT 1 default Limit 90F 32C The maximum heating set temperature is 90F 32C degrees with no heat mode temperature restrictions 2 Limit 80F 27C The maximum heating set temperature is 80F 27C degrees 3 Limit 70F 21C The maximum h
31. upplied by your heating cooling system using the System Common wire This can be used alone or in addition to installing batteries as a backup NOTE when using batteries connecting the System Common wire to the thermostat is not necessary for heating and cooling to function properly 5 If your old thermostat has BOTH an 0 wire and a B wire present then B is likely a System Common power wire and can either be connected to the C terminal or taped off and unused Connecting a System Common wire to this thermostat s B O terminal will damage the thermostat and also your heating and cooling system equipment 6 If your existing thermostat connections contain a wire labeled as W2 AUX E or X2 this would indicate that you have additional heating stages present This is a single stage thermostat and cannot accomodate any of these system components You will need to select a different model 7 If replacing an old thermostat that has a mechanical time clock on the front panel there may be TWO wires labeled as C for the clock power Do not connect either of them to this thermostat TECHNICAL ASSISTANCE If you have any problems installing or using this thermostat please carefully and thoroughly review the instruction manual If you still require assistance please contact our Technical Assistance department at 856 234 8803 during regular business hours between 8 00AM and 4 30PM Easte
32. you can press the SET button to save your changes and return back to the normal run mode NOTE If a temperature program routine is not desired you may change ITEM 02 in the Setup Options to 3 for manual non programmable BASIC HEATING AND COOLING OPERATION Basic operation of your heating or cooling system can be obtained by selecting HEAT or COOL on the System Mode switch and using UP or DOWN to adjust the temperature To maintain a single fixed temperature you can use the HOLD button If there is a padlock present on the display screen the keypad lockout feature is enabled both of the mode slide switches are still functional WIRING DIAGRAM NOTES 1 If the wiring diagrams do not clearly represent or match your system please refer to TECHNICAL ASSISTANCE below and contact us before removing any of your existing thermostat wires 2 All of the DASHED wires shown in the wiring diagrams are either optional or their usage depends upon your specific system type EXAMPLE Diagram 1 shows the fan wire as optional This does not infer that your system does not have a fan only that there may not be a wire for it 3 The terminal letters shown in black represent typical wiring usage The terminal letters shown in gray represent other possible wiring letter designations that you might see on your particular brand and model of thermostat 4 The optional C terminal is used for powering the thermostat by the 24 volts s
Download Pdf Manuals
Related Search
Related Contents
DOMEZBULB Z-Wave Dimmable LED Light Bulb Quick Descargar - Innova Pro User`s Manual Stereo Amplifier Amplificateur Stéréo IR HIGH SPEED DOME USER MANUAL ALT-320/HLT-120 TECHNICAL & SERVICE MANUAL Here is a Parts Catalog for Jaguars the 1st part is splash then come 6603DT - Dimasur avvertenza Copyright © All rights reserved.