Home

FUENTE DE ALIMENTACIÓN PARA ELECTROFORESIS

image

Contents

1. 2 4 to start the power supply Note During operation the value of the different parameters can be changed by selec ting the desired parameter with the selection key 2 5 and then increasing 2 6 or decre asing 2 7 its value E g if you need to work at a constant voltage of 200 V and the power supply only reaches to 150 V and keeps a constant current of 100 mA the current value can be increased during operation to make the power supply reach 200 V and keep this value constant Note By pressing the selection key during operation the selected values of voltage Us current Ic and time Ts will be displayed as well as their real values U I y T Note To stop temporarily operation press Start Pause 2 4 the power supply will stop immediately and STOP will be displayed To restart operation press the selection key 2 5 to move the cursor to GO ON and then press Start Pause 2 4 If you are not using the power supply for a long period of time please make sure it is disconnected from the net and protected from dust this way you will avoid accidents and will extend its working life Security The power supply must be used by previously qualified staff that knows how the equipment works thanks to the user manual Put the power supply on top of a horizontal plane and stable table making a free space of at least 30 cm per side Do not put the power supply near any warm supply burners blowlamps nor expo
2. HR Alimentaci n CA 220 V 10 50 Hz 2 Dimensiones 315x290x128 mm Peso 5 Kg Aplicaciones DNA RNA prote nas Western blot Version 1 May 07 electroforesis 2D transferencia semi seca vp Instruction manual 5301000x Page 5 a j CASTELLANO 4 INSTALACI N PUESTA EN MARCHA Inspecci n preliminar Desembale la fuente de alimentaci n retire el pl stico que la envuelve y quite la pro tecci n de poliesp n en que viene encajada Retire todas las protecciones y sin conectar la fuente de alimentaci n a la red el ctrica aseg rese de que no presenta ning n da o debi do al transporte De ser as comuniquelo inmediatamente a su transportista o suminis trador para que pueda hacer las debidas reclamaciones en el plazo establecido Guarde el embalaje ya que siempre se deben realizar las devoluciones en su embalaje original con todos los accesorios suministrados Compruebe los accesorios que usted debe recibir junto al equipo Equipo fuente alimentaci n Cable Schuko Garant a Manual de instrucciones Solo aceptamos devoluciones de equipos en los 15 d as posteriores al env o y siem pre que vengan completos en su embalaje original Instalaci n Antes de comenzar a utilizar el instrumento es conveniente familiarizarse con sus com ponentes y fundamentos b sicos as como con las funciones de sus controles LEA DETALLADAMENTE ESTE MANUAL DE INSTRUCCIONES ANTES DE OPERAR CON ESTE EQUIP
3. connected to up to 4 elec trophoretic cells at the same time being ideal for clinical diagnostic and research labora tories 2 DESCRIPTION 1 1 Fuse 1 2 AC plug 1 3 Fan it starts operating when the voltage or current reaches the selected value 1 4 Vent 1 4 CE 12 See Imput power Max output 60 350VA 600V 400mA 240W Pag 12 Manual de instrucciones 5301000x Revision 1 Mayo 07 CASTELLANO sopletes ni exponga el equipo directamente a la luz del sol Evite las vibraciones el polvo y los ambientes muy secos Durante su funcionamiento el material peligroso como liquidos inflamables o material patol gico deber n estar fuera del rea de trabajo Cuando no vaya a hacer uso del equipo por largos per odos de tiempo aseg rese de que est desconectado de la red para evitar posibles accidentes Para cualquier manipulaci n de limpieza verificaci n de los componentes o sustituci n de cualquier componente ej sustituci n de fusible es imprescindible apagar el equipo y desconectarlo de la toma de corriente No intente repararlo usted mismo adem s de perder la garant a puede causar da os en el funcionamiento general del equipo as como lesiones a la persona quemaduras heri das y da os a la instalaci n el ctrica Procure que no entre agua en el cuadro de controles aunque ste se encuentre debida mente aislado Si por cualquier causa sospecha que ha entrado agua o cual
4. desea conectar dos o m s cubetas al mismo tiempo deber trabajar a voltaje constante ya que el valor de la corriente que se visualiza en pantalla es la suma de corriente de las diferentes cubetas pero el voltaje de las diferentes cubetas es el mismo 2 Pulse el interruptor encendido apagado 2 2 La pantalla se enciende se escuchan cuatro pitidos y finalmente se visualizar n en pantalla los ltimos par metros selecciona dos 3 Si desea trabajar con los mismos par metros presione el interruptor Start Pause 2 4 y el equipo comienza a funcionar 4 Para cambiar los par metros de voltaje corriente y tiempo de funcionamiento siga las siguientes instrucciones Voltaje Las fuentes de alimentaci n Nahita presentan un rango de selecci n de voltaje de 6 600 V Modelo 301 6 y de 2 300 V Modelo 301 7 seleccionables cada 1 V Presione el bot n de selecci n 2 5 en pantalla visualizar Moviendo la flecha mediante la pulsaci n del bot n de selecci n seleccione el par metro que desea modifi car en este caso el voltaje de salida Ug Presione los botones de incremento 2 6 y disminuci n 2 7 hasta ajustar el par metro seleccionado al valor deseado Nota Para trabajar a voltaje constante deber seleccionar el voltaje al que desea tra bajar y a continuaci n el valor m ximo de corriente permitido por el rango de la fuente de alimentaci n De este modo la fuente de alimentaci n llegar al valor de voltaj
5. different electrophoresis cells while the voltage is the same for all the cells 2 Press power on off 2 2 The display will light up and four beeps will sound finally the last parameters selected will be shown 3 To work with the same parameters press Start Pause 2 4 and the equipment will start running 4 To change the value of voltage current and running time proceed as follows Voltage Nahita power supplies present a voltage selecting range of 6 600 V Model 301 6 and 2 300 V Model 301 7 with increments of 1 V Press the selection key 2 5 a cursor will be displayed Move the cursor by pres sing the selection key until selecting the parameter to be changed the output voltage in this case Us Press the increase 2 6 and decrease 2 7 keys until adjusting the selected parameter to the desired value Note To work at a constant voltage adjust the voltage to the working value and then adjust the current to the maximum value allowed in the range of the power supply Thus when the power supply reaches the selected voltage value will keep it constant though the current value is lower than the selected Current Nahita power supplies present a current selecting range of 4 400 mA with increments of 1 mA Model 301 6 and 5 2000 mA with increments of 2 mA Model 301 7 Press the selection key 2 5 a cursor will be displayed Move the cursor by pres sing the selection key until selecting the parame
6. AUXILAB S L Material de laboratorio DECLARACION DE CONFORMIDAD CE CE DECLARATION OF CONFORMITY DECLARATION DE CONFORMITE CE El fabricante The manufacturer Le fournisseur AUXILAB S L Declara que el equipo Declare that the equipment Declare que l appareil FUENTES DE ALIMENTACION PARA ELECTROFORESIS POWER SUPPLIES FOR ELECTROPHORESIS GENERATEUR POUR ELECTROPHORESE C digo Code Code 53010006 53010007 Cumple las siguientes directivas Meet the following directives Accomplit les directives suivantes 73 23 CE Directiva de seguridad el ctrica Directive for electrical safety Directive de s curit lectrique 89 336 CE Directiva de Compatibilidad electromagn tica CEM Directive for electromagnetic compatibilit y EMC Directive de compatibilit electromagn tique CEM Cumple las siguientes Normas Meet the following Standars Accomplit les normes suivantes EN 61326 1997 A2 2001 Material el ctrico para medida control y uso en laboratorio Requisitos de compatibilidad electromagn tica CEM Electrical equipment for measurement control and laboratory use EMC requirements Mat riel lectriques de mesure de commande et de laboratorie Prescriptions relatives la CEM Fdo Alfonso Ainciburu Sanz DIRECTOR GERENTE BERIAIN a 27 de FEBRERO de 2010 Pol Morea Norte Calle D N 6 31191 Beriain Navarra ESPA A Tel fono 34 948 310 513 Fax 34 948 312 071 948 310 500
7. O CON EL FIN DE OBTENER LAS MAXIMAS PRES TACIONES Y UNA MAYOR DURACI N DEL MISMO Coloque la fuente de alimentaci n sobre una mesa horizontal plana y estable creando un espacio libre de al menos 30 cm por cada lado No coloque el equipo en zonas pr xi mas a fuentes de calor mecheros sopletes ni lo exponga directamente a la luz del sol etc Evite en el lugar de trabajo la presencia de productos inflamables o t xicos La fuente de alimentaci n se suministra con un cable Schuko est ndar Inserte el cable de alimentaci n de corriente alterna CA a la base de corriente 220 V 50 Hz 10 pro vista de toma de tierra y por el otro extremo al conector de la fuente de alimentaci n Ni el fabricante ni el distribuidor asumir n responsabilidad alguna por los da os ocasionados al equipo instalaciones o lesiones sufridas a personas debido a la inob servancia del correcto procedimiento de conexi n el ctrica La tensi n debe ser de 220 V 50 Hz 10 1 Conecte los cables de la cubeta de electroforesis a la fuente de alimentaci n Aseg rese de que conecta los cables con los terminales correctos TA E j P g 6 Manual de instrucciones 5301000x Revisi n 1 Mayo 07 ENGLISH Red lead Red terminal positive Black lead Black terminal negative Note In case of connecting two or more cells at the same time it will be necessary to work at a constant voltage since the current displayed is the sum of the currents of the
8. al 5301000x Page 3 yA j CASTELLANO INDIO INS Castellano A eastee de eee N R E RERA NDICE DE CONTENIDOS 1 APLICACIONES DEL INSTRUMENTO nnn 4 2 DESCRIPCI N cas 4 5 6 9 ANEXO I CERTIFICADO CE cc nana 20 1 APLICACIONES DEL INSTRUMENTO Las fuentes de alimentaci n Nahita est n especialmente dise adas para trabajar junto con cubetas de electroforesis vertical y horizontal Controladas mediante microprocesa dor las fuentes de alimentaci n permiten trabajar a voltaje o corriente de salida constan tes y presentan tambi n un temporizador para trabajar en periodos de tiempo concretos durante los cuales el proceso puede ser detenido y retomado posteriormente Las fuentes de alimentaci n Nahita presentan 4 salidas en paralelo para conectar hasta 4 cubetas distintas al mismo tiempo ofreciendo una gran capacidad de uso y resultando por tanto ideales en laboratorios de investigaci n o diagn stico cl nico 2 DESCRIPCI N Y COMPONENTES 1 1 Fusible 1 2 Clavija CA 1 3 Ventilador comienza a funcionar cuando la corriente de salida alcanza el valor seleccionado 1 4 Rejilla de ventilaci n 1 4 1 1 a l AAOOOOOOCOCOOCOCOOCOOOO AAOOCOOOOCOOCOOOONOO cE Model DYY 6C Imput power 350VA Max output 600V 400mA 240W 1 2 Revisi n 1 Mayo 07 ENGLISH When you are not using the power supply for a long period of time please make sure it is unplugged in order to avoid possible accidents It is
9. correo auxilab es www auxilab com CIF B31072218 FUENTE DE ALIMENTACI N PARA ELECTROFORESIS ELECTROPHORESIS POWER SUPPLY Este manual es parte inseparable del aparato por lo que debe estar disponible a todos los usuarios del equipo Le recomendamos leer atentamente el presente manual y seguir rigurosamente los proce dimientos de uso para obtener las m ximas prestaciones y una mayor duraci n del mismo This manual should be available for all users of these equipments To get the best results and a higher duration of this equipment it is advisable to read carefully this manual and follow the processes of use Revisi n 1 Mayo 2007 Manual de instrucciones 5301000x P g 1 ENGLISH DISINFECTED THEY WOULD NOT BE ALLOWED TO REPAIR BY OUR t ATTENTION IF EQUIPMENTS ARE NOT PROPERLY CLEAN AND TECHNICAL SERVICE INSTRUCTIONS ON ENVIRONMENT PROTECTION gt At the end of its life cycle please do not dispose of this equipment NI by throwing it in the usual garbage hand it over a collection point for N the recycling of electrical and electronic appliances It does not con tain dangerous or toxic products for humans but a non adequate dis posal would damage the environment The materials are recyclable as mentioned in its marking By recycling material or by other forms of re utilization of old appliances you are making an important contribu tion to protect our environment Please inquire at the community administration f
10. ductos que puedan rayar ya que deterioran el equipo limitando su TA Version 1 May 07 Instruction manual 5301000x Page 9 z 4 CASTELLANO vida util Para la limpieza del equipo recomendamos se utilice un trapo libre de pelusa humede cido con agua jabonosa que no contenga productos abrasivos ATENCI N NO SE ADMITIR NING N APARATO PARA REPARAR QUE NO ESTE DEBIDAMENTE LIMPIO Y DESINFECTADO INSTRUCCIONES SOBRE PROTECCI N DEL MEDIO gt na AMBIENTE No se deshaga de este equipo tir ndolo a la basura ordinaria cuando haya terminado su ciclo de vida ll velo a un punto de recogida para el reciclaje de aparatos el ctricos y electr nicos No contiene elementos peligrososo t xicos para el ser humano pero una eliminaci n no adecuada perjudicar a al medio ambiente Los materiales son reciclables tal como se indica en la marcaci n Al reciclar materia les o con otras formas de reutilizaci n de aparatos antiguos esta Ud haciendo una con tribuci n importante a la protecci n del medio ambiente Por favor p ngase en contacto con la administraci n de su comunidad para que le ase soren sobre los puntos de recogida TA gi j P g 10 Manual de instrucciones 5301000x Revisi n 1 Mayo 07 ENGLISH Thank you for choosing this equipment We sincerely wish that you enjoy your Nahita electrophoresis power supply We highly recommend looking after this equipment accor ding to what is stated in this manual Nahita dev
11. e selec cionado y se mantendr constante en l aunque el valor de intensidad sea menor que el seleccionado Corriente Las fuentes de alimentaci n Nahita presentan un rango de corriente de 4 400 mA selec cionable cada 1 mA Modelo 301 6 y de 5 2000 mA seleccionable cada 2 mA Modelo 301 7 Presione el bot n de selecci n 2 5 en pantalla visualizar Moviendo la flecha mediante la pulsaci n del bot n de selecci n seleccione el par metro que desea modifi car en este caso la corriente de salida Is Presione los botones de incremento 2 6 y disminuci n 2 7 hasta ajustar el par metro seleccionado al valor deseado Nota Para trabajar a corriente constante deber seleccionar la corriente a la que desea trabajar y a continuaci n el valor m ximo de voltaje permitido por el rango de la fuente de alimentaci n De este modo la fuente de alimentaci n llegar al valor de corriente seleccionado y se mantendr constante en l aunque el valor de voltaje sea menor que el seleccionado Version 1 May 07 Instruction manual 5301000x Page 7 E j CASTELLANO Tiempo Las fuentes de alimentaci n Nahita presentan un rango de selecci n de tiempo de 1 min a 99 h 59 min Presione el bot n de selecci n 2 5 en pantalla visualizar Moviendo la flecha mediante la pulsaci n del bot n de selecci n seleccione el par metro que desea modifi car en este caso el tiempo de funcionamiento Ts Presione los b
12. e the warranty and may provoke damages to the general operating system or the electrical installation as well as injuries to the people that usually handle the power supply burns hurts or damages in nearby equipments In the event of breakdown please contact your distributor to overhaul through Nahita Technical Assistance Department Cleaning Never use scourers or substances that can grate for cleaning metallic parts such as stain less steel aluminium coatings etc as they damage the power supply and produce an early ageing of the equipment Use a fluff free cloth dampened with soaped water that does not contain abrasives Version 1 May 07 Instruction manual 5301000x Page 17 a j ENGLISH Time Nahita power supplies present a time selecting range from 1 min to 99 h 59 min Press the selection key 2 5 a cursor will be displayed Move the cursor by pres sing the selection key until selecting the parameter to be changed the operating time in this case Ts Press the increase 2 6 and decrease 2 7 keys until adjusting the selected parameter to the desired value 5 Press the selection key 2 5 to move the cursor to T 0 00 Start 6 Press Start Pause 2 4 4 beeps will sound and then the power supply will start run ning Note If pressing Start Pause 2 4 without previously selecting T 0 00 Start 5 beeps will sound and the cursor will automatically move to T 0 00 Start Then press Start Pause
13. elops its products according to the CE marking regulations as well as emphasizing the ergonomics and security for its user The correct using of the equipment and its good quality will permit you to enjoy this equipment for years The improper use of the equipment can cause accidents and electric discharges circuit breakers fires damages etc Please read the point of Maintenance where we expose the security notes TO GET THE BEST RESULTS AND A HIGHER DURATION OF THE EQUIP MENT IT IS ADVISABLE TO READ THOROUGHLY THIS MANUAL BEFORE OPERATING WITH THE EQUIPMENT Please bear in mind the following This manual is inseparable from the Nahita electrophoresis power supply so it should be available for all the users of this equipment You should carefully handle the equipment avoiding sudden movements knocks free fall of heavy sharp objects on it Avoid spilling liquids inside the equipment Never dismantle the different pieces of the equipment to repair it yourself since it could produce a defective use of the whole equipment and a loss of the product warranty as well as injuries on people that handle the power supply To prevent fire or electric discharges avoid dry or dusty environments In case it may happen unplug the equipment immediately If you have any doubt about setting up installation or functioning do not hesitate in contacting your wholesaler You can also tell us any doubts or suggestions you have by contacting Nah
14. essential to have the equipment switched off and unplugged from the net before cleaning checking components or replacing any piece e g replacement of a fuse Never try to repair the power supply by yourself since you will lose the warranty and may provoke damages to the general operating system or the electrical installation as well as injuries to the people that usually handle the equipment burns hurts Try not to spill any liquid on the control panel though it is properly insulated In case you have any doubts do please immediately unplug the equipment see Maintenance Made under the European regulations for electrical security electromagnetic compati bility and security on machines 5 MAINTENANCE AND CLEANING To get the best results and a higher duration of the power supply it is essential to follow the processes of use Note All the processes of use mentioned below will not have any value unless you keep a continued and careful maintenance Please follow the processes of use of this manual This manual should be available for all users of this equipment Always use original components and supplies Other devices can be similar but they can damage the equipment The power supply is supplied with a Schuko wire It has to be plugged to an earth con nection and the socket should be handy and ready to unplug the equipment in case of emergency Never try to repair the power supply by yourself since you will los
15. iente de todo el equipo as como da os a las per sonas que lo manipulan Para prevenir fuego o descargas el ctricas evite los ambientes secos y polvorientos Si esto ocurre desenchufe inmediatamente el equipo de la toma de corriente Cualquier duda puede ser aclarada por su distribuidor instalaci n puesta en marcha funcionamiento Usted puede tambi n mandarnos sus dudas o sugerencias a la siguien te direcci n de correo del Servicio T cnico Nahita asistencia auxilab es o bien llamando al Tel 807117040 0 30 Euros min Este equipo est amparado por la Ley de garant as y bienes de consumo 10 2003 No se consideran en garant a las revisiones del equipo La manipulaci n del equipo por personal no autorizado provocar la p rdida total de la garant a e Los fusibles o accesorios as como la p rdida de los mismos no est n cubiertos por dicha garant a Tampoco estar n cubiertos por el periodo de garant a las piezas en su des gaste por uso natural Aseg rese de guardar la factura de compra para tener derecho de reclamaci n o pres taci n de la garant a En caso de enviar el equipo al Servicio T cnico adjunte factura o copia de la misma como documento de garant a El fabricante se reserva los derechos a posibles modificaciones y mejoras sobre este manual y equipo ATENCI N NO SE ADMITIR NING N APARATO PARA REPARAR QUE NO EST DEBIDAMENTE LIMPIO Y DESINFECTADO Version 1 May 07 Instruction manu
16. ime etc 2 6 24 2 8 T N 3S o bW a 2 3 2 5 gt E GO GO GO ES f 3 TECHNICAL SPECIFICATIONS Code 53010006 53010007 Output voltage 6 600 V 2 300 V Output current 4 400 mA 5 2000 mA Output power 240 W 300 W Resolution 1V 1 mA 1V 2 mA Timer 1 min 99 h 59 min Stability lt 1 constant voltage lt 2 constant current Precision lt 2 constant voltage lt 3 constant current Ripple factor lt 2 Working conditions 5 40 C 80 RH Power AC 220 V 10 50 Hz 2 Dimensions 315x290x128 mm Weight 5 Kg Applications DNA RNA proteins Western blotting Version 1 May 07 2D electrophoresis semi dry blotting Instruction manual 5301000x Page 13 Vi ENGLISH INDEX OF LANGUAGES INDEX OF CONTENTS 1 USES OF THE INSTRUMENT 2 DESCRIPTION 5 MAINTENANCE AND CLEANING ooconcconcconconnonnconnranorennconncnnconn renos rencren cerros 17 ANNEX I CE CERTIFICATE viii a 20 1 USES OF THE INSTRUMENT Nahita power supplies are specially designed to operate together with the horizontal and vertical electrophoresis cells Controlled by microprocessor power supplies can work at constant voltage or constant current output and they also present timer control to work in concrete periods of time with the capability to pause and resume a run Nahita power supplies present 4 parallel output jacks to be
17. ita Technical Assistance Department by email to asistenciaQauxilab es or by telephone 34 807 117 040 0 30 Euros min This equipment is protected under the Warranties and consumer goods regulation 10 2003 Overhaul is not covered by the equipment warranty Operations made by non qualified staff will automatically produce a loss of the warrantly Neither fuses nor accessories including their loss are covered by the product s warranty The warranty neither covers piece s deterioration due to the course of time Please make sure you keep the invoice either for having the right to claim or asking for warranty coverage In case you have to send the equipment to Nahita Technical Assistance Department you should enclose the original invoice or a copy as guarantee Manufacturer reserves the right to modify or improve the manual or equipment DISINFECTED THEY WOULD NOT BE ALLOWED TO REPAIR BY OUR TECHNICAL SERVICE t ATTENTION IF EQUIPMENTS ARE NOT PROPERLY CLEAN AND Version 1 May 07 Instruction manual 5301000x Page 11 a
18. nient for you to familiarize with its compo nents and basic essentials as well as with its control functions PLEASE READ THOROUGHLY THE INSTRUCTIONS BEFORE CONNECTING AND OPERATING WITH THIS EQUIPMENT WITH THE AIM OF ACHIEVING THE HIGHEST FEATURES AND THE MAXIMUM DURABILITY OF THE INS TRUMENT Please put the power supply on top of a horizontal plane and stable table making a free space of at least 30 cm per side Do not put the power supply near any warm supply bur ners blowlamps nor expose it directly to the sun etc During operation dangerous material such as flammable or infectious liquids must be out of the working area The power supply is supplied together with a Schuko wire Please insert the wire that feeds the AC electric current in the base of current 220 V 50 Hz 10 provided with earth wire and to the other end to the power supply connector Neither the manufacturer nor the distributor will assume any responsibility for the damages produced to the equipment during its installation or damages to people suf fered by the improper use of the electric connection The tension should be 220 V 50 Hz 10 1 Plug the leads of the electrophoresis cell lid to the power supply Make sure that the leads are connected to the proper output terminal TF i j P g 14 Manual de instrucciones 5301000x Revisi n 1 Mayo 07 CASTELLANO Cable rojo Terminal rojo positivo Cable negro Terminal negro negativo Nota Si
19. or the authorized disposal location TAL gi J Pag 18 Manual de instrucciones 5301000x Revision 1 Mayo 07 CASTELLANO Gracias por haber adquirido este equipo Deseamos sinceramente que disfrute de la fuente de alimentaci n para electroforesis Nahita Le recomendamos que cuide el equipo conforme a lo expuesto en este manual Nahita desarrolla sus productos seg n las directrices del marcado CE y haciendo hin capi en la ergonom a y seguridad del usuario La calidad de los materiales empleados en la fabricaci n y el correcto proceder le per mitir n disfrutar del equipo por muchos a os El uso incorrecto o indebido del equipo puede dar lugar a accidentes descargas el ctri cas cortocircuitos fuegos lesiones etc Lea el punto de Mantenimiento donde se recogen aspectos de seguridad LEA DETALLADAMENTE ESTE MANUAL DE INSTRUCCIONES ANTES DE OPERAR CON ESTE EQUIPO CON EL FIN DE OBTENER LAS MAXIMAS PRES TACIONES Y UNA MAYOR DURACI N DEL MISMO Tenga especialmente presente lo siguiente Este manual es parte inseparable de la fuente de alimentaci n para electoforesis por lo que debe estar disponible para todos los usuarios del equipo Debe manipularse siempre con cuidado evitando los movimientos bruscos golpes ca das de objetos pesados o punzantes evite el derrame de l quidos en su interior Nunca desmonte el equipo para repararlo usted mismo adem s de perder la garant a podr a producir un funcionamiento defic
20. otones de incremento 2 6 y disminuci n 2 7 hasta ajustar el par metro seleccionado al valor deseado 5 Presione el bot n de selecci n 2 5 hasta colocar el cursor en T 0 00 Start 6 Presione Start Pause 2 4 escuchar 4 pitidos la fuente de alimentaci n comienza a funcionar Nota Si ha presionado Start Pause 2 4 sin seleccionar previamente T 0 00 Start escuchar 5 pitidos y el cursor se mover autom ticamente hasta el comando T 0 00 Start Pulse entonces Start Pause 2 4 para poner en funcionamiento la fuente de ali mentaci n Nota Mientras la fuente de alimentaci n est en funcionamiento se puede modificar el valor de los par metros seleccionando en primer lugar el par metro deseado con el bot n correspondiente 2 5 y a continuaci n aumentando 2 6 o disminuyendo 2 7 su valor Ej si desea trabajar a un voltaje constante de 200 V y la fuente de alimentaci n llega a 150 V y mantiene una corriente constante de 100 mA durante el funcionamiento de la fuente puede aumentar el valor de corriente para hacer que la fuente llegue hasta 200 V y se mantenga constante en este valor Nota Presionando el bot n de selecci n durante el funcionamiento de la fuente podr visualizar en pantalla el valor seleccionado de voltaje Us corriente Is y tiempo Ts y sus correspondientes valores actuales U I y T Nota Una vez en funcionamiento si quiere detener temporalmente la fuente de ali mentaci n
21. presione Start Pause 2 4 la fuente de alimentaci n se para inmediatamente y en pantalla se visualizar STOP Para retomar su funcionamiento presione el bot n de selecci n 2 5 hasta mover el cursor a GO ON y presione Start Pause 2 4 Cuando no vaya a hacer uso de la fuente de alimentaci n durante largos per odos de tiempo aseg rese de que est desconectada de la red y prot jala del polvo evitando as posibles accidentes y prolongando la vida til del equipo Seguridad La fuente de alimentaci n debe ser utilizada por personal cualificado previamente que conozca el equipo y su manejo mediante el manual de uso Coloque la fuente de alimentaci n sobre una mesa horizontal plana y estable creando un espacio libre de al menos 30 cm por cada lado No coloque la fuente de alimentaci n en zonas pr ximas a fuentes de calor mecheros 7 gwi j P g 8 Manual de instrucciones 5301000x Revisi n 1 Mayo 07 ENGLISH 2 1 Output terminal positive red negative black 2 2 Power on off 2 3 Operation light it switches on when the power supply starts operating 2 4 Start Pause 2 5 Selection key it moves the cursor to the different parameters that can be adjusted 2 6 Increase it increases the value of the parameter selected with the selection key 2 7 Decrease it decreases the value of the parameter selected with the selection key 2 8 LCD display it shows the value of voltage output current selected t
22. quier l quido desconecte el equipo inmediatamente ver Mantenimiento Fabricado seg n las directivas europeas de seguridad el ctrica compatibilidad electro magn tica y seguridad en m quinas 5 MANTENIMIENTO Y LIMPIEZA Para un adecuado funcionamiento de la fuente de alimentaci n es necesario seguir algunas recomendaciones Nota Todas las normas de utilizaci n citadas anteriormente carecer n de valor si no se realiza una continua labor de mantenimiento Siga las instrucciones y advertencias relativas a este manual Tenga este manual siempre a mano para que cualquier persona pueda consultarlo Utilice siempre componentes y repuestos originales Puede ser que otros dispositivos sean parecidos pero su empleo puede da ar el equipo La fuente de alimentaci n dispone de un cable de red Schuko ste debe conectarse a una toma de corriente que est conectada a tierra debiendo quedar a mano para poder desconectarlo en caso de emergencia No intente repararlo usted mismo adem s de perder la garant a puede causar da os en el funcionamiento general del equipo as como lesiones a la persona quemaduras heri das y da os a la instalaci n el ctrica o equipos el ctricos cercanos En caso de aver a dir jase a su proveedor para la reparaci n trav s del Servicio T cnico de Nahita Limpieza Para la limpieza de las partes met licas acero inoxidable aluminio pinturas etc nunca utilice estropajos o pro
23. se it directly to the sun etc Avoid vibrations dust and dry environments During operation dangerous material such as flammable or infectious liquids must be out of the working area ce ia na gi j Pag 16 Manual de instrucciones 5301000x Revision 1 Mayo 07 CASTELLANO 2 1 Terminal de salida positivo rojo negativo negro 2 2 Interruptor encendido apagado 2 3 Indicador de funcionamiento permanece encendido mientras la fuente de alimen taci n est en funcionamiento 2 4 Start Pausa 2 5 Bot n de selecci n mueve el cursor entre los distintos par metros que pueden ser ajustados 2 6 Incremento aumenta el valor del par metro seleccionado mediante el bot n de selecci n 2 7 Disminuci n disminuye el valor del par metro seleccionado mediante el bot n de selecci n 2 8 Pantalla LCD muestra el valor del voltaje corriente de salida tiempo seleccionado etc 2 6 24 2 8 T al 2 3 E 3S o eW 22 2 5 J iC GO GO GO 21 A 3 ESPECIFICACIONES TECNICAS Referencia 53010006 53010007 Voltaje salida 6 600 V 2 300 V Corriente salida 4 400 mA 5 2000 mA Potencia salida 240 W 300 W Resoluci n 1V 1mA 1V 2mA Temporizador 1 min 99 h 59 min Estabilidad lt 1 voltaje constante lt 2 corriente constante Precisi n lt 2 voltaje contante lt 3 corriente constante Factor Ripple lt 2 Condiciones trabajo 5 40 C lt 80
24. ter to be changed the output current in this case Ic Press the increase 2 6 and decrease 2 7 keys until adjusting the selected parameter to the desired value Note To work at a constant current adjust the current to the working value and then adjust the voltage to the maximum value allowed in the range of the power supply Thus when the power supply reaches the selected current value will keep it constant though the voltage value is lower than the selected Version 1 May 07 Instruction manual 5301000x Page 15 E j ENGLISH 4 INSTALLATION SETTING UP Preliminary inspection Unwrap the power supply take off the involving plastic and take off the polyspan pro tection in which it comes fitted Take off all protections and without connecting the power supply to the electrical current make sure that the equipment does not present any dama ge because of the shipment In case it presents any damage tell it immediately to your transport agent or dealer so that they can make the claims in the correct time limit Please keep the original wrapping you will always need it for returns enclosed with all the accessories supplied Please check that all the accessories are enclosed with the equipment Power supply Schuko wire Warranty User s manual We will only accept any equipment return within 15 days after delivery and provided it comes in its original wrapping Installation Before using the power supply it is conve

Download Pdf Manuals