Home

Regulador GRT7-TH4 - ING GRAMEYER

image

Contents

1. generador Despu s de esto ruede el trimpot P2 completamente en el sentido horario en esta operaci n debe ocurrir una baja de tensi n en el generador Volviendo el trimpot nuevamente para la posici n antihorario la tensi n deber aumentar Caso esto ocurrir la polaridad del TC est correcta caso contrario el TC deber ser invertido Cuando se conecta algunos generadores en paralelo este procedimiento es necesario en cada generador para garantizarse que todos los TC s est n polarizados de la misma manera El transformador de corriente para compensaci n de reactivos deber estar en la fase S del generador y la se al de realimentaci n en la fase R Para certificar la correcta polarizaci n del TC debe aplicarse cargas Resistivas Inductivas y verificar si el sistema responde conforme se muestra a continuaci n Cargas resistivas Con carga resistiva no presentar compensaci n manteniendo la corriente de excitaci n y tensi n del generador constante en el valor ajustado a trav s del trimpot Vad Si existe compensaci n indica que el TC est en la fase errada Cargas Inductivas Con aplicaci n de cargas inductivas presentar una compensaci n negativa disminuyendo de la corriente de excitaci n correspondiendo a la ganancia ajustada en el trimpot droop del O al 1596 tensi n ajustada en Vad Si la compensaci n es positiva indica que el TC est invertido Cargas Capacitivas Con aplicaci n de cargas capacitivas
2. ser abrigado en local seco ventilado y que no ocurra la incidencia directa de los rayos solares bien como la lluvia viento y otras intemperies para garantizar la manutenci n de sus caracter sticas funcionales Si no fueren observadas las recomendaciones arriba podr eximir el proveedor del equipo de cualquier responsabilidad pelos dafios decurrentes bien como la perdida de la garant a sobre el equipo o parte danada 3 INTRODUCCI N Los reguladores electr nicos de Tensi n anal gicos de la serie GRT7 son equipos compactos de alta confiabilidad y de bajo costo los cuales fueron desarrollados dentro de la mas alta tecnolog a para regulaci n de Tensi n en generadores sincr nicos sin escobillas brushless Su circuito de control y regulaci n utiliza semiconductores y circuitos integrados probados dentro de los m s r gidos padrones de calidad No poseen componentes mec nicos para encender el campo y su sistema es totalmente est tico y encapsulado en resina ep xi resistente salinidad Pueden suportar vibraciones hasta 50mm s Poseen ajuste de Tensi n interno por trimpot y externo por potenci metro posibilitando un rango de ajuste de la tensi n del generador Su sistema de controle PID es ajustado a trav s de trimpots que regulan el ganado proporcional y el ganado integral posibilitando un amplio rango de ajuste o que permite operaci n con los m s diversos tipos de generadores y con las m s variadas caracter sticas
3. em qualquer tempo o cliente poder solicitar material atualizado que lhe ser fornecido sem encargos decorrentes Em caso de perda do manual de instru es a WEG poder fornecer exemplar avulso e se necess rio informa es adicionais sobre o produto As solicita es poder o ser atendidas desde que informado o n mero de s rie e modelo do equipamento ATENC O 1 imprescind vel seguir os procedimentos contidos neste manual para que a garantia tenha validade 2 Os procedimentos de instala o opera o e manuten o do gerador dever o ser feitos por pessoal qualificado NOTAS 1 A reprodu o das informa es deste manual no todo ou em partes permitida desde que a fonte seja citada 2 Caso este manual seja extraviado o arquivo eletr nico em formato PDF est dispon vel no site www weg net ou poder ser solicitada outra c pia impressa Regulador Autom tico de Tens o GRT7 TH4 39 ON FP G Na 10 11 12 13 14 15 16 www weg net ug INDICE INFORMA ES DE SEGURANTCA res ne 43 INFORMA ES SOBRE 43 INTRODU O conca a der 43 CARACTER STICAS T CNICAS eere u u uuu u 44 ETIQUETA DE IDENTIFICA O ee u EE E 44 DIAGRAMA DE BLOCOS uuu dio 45 FUN O DOS TRHIMPOTS sesi n 45 AJUSTE DOS TRIMPO
4. rio Com o regulador ligado usar bateria externa Tens o residual muito baixa 12Vcc para for ar excita o Gerador n o escorva Bornes F e F invertidos Inverter Din mica desajustada Ajustar trimpot s P3 e P4 Tens o gerada oscila a vazio Tens o de excita o do gerador muito Colocar resistor 10 1 100W em s rie com o pequena campo Tens o oscila em um ponto de carga Terceira harm nica da bobina auxiliar Eliminar bobina auxiliar e proceder conex o espec fico elevada conforme diagramas da p gina 13 Falta de realimenta o Verificar se as fases do gerador est o Circuito eletr nico com defeitos pres Eme na reanmenta o Tens o dispara i Para regulador encapsulado efetuar a troca do Tens realimenta o incompat vel ens o de realimenta o incompat ve mesmo com o regulador Para bateria de grupo gerador diesel onde o neutro do gerador estiver aterrado dever sempre ser utilizada bateria independente 15 MANUTEN O PREVENTINA necess rio proceder se inspe es peri dicas na unidade para assegurar se de que a mesma encontra se limpa e livre do acumulo de p e outros detritos E vital que todos os terminais e conex es dos fios sejam mantidos livres de corros o 16 GARANTIA Vide o Manual de Instala o e Manuten o do Gerador Weg Linha G WEG Equipamentos El tricos S A International Divi
5. rio em cada m quina para assegurar se que todos os TC s est o polarizados da mesma forma Conforme o diagrama fasorial a tens o de realimenta o sofre uma influ ncia provocada pela corrente proveniente da fase S que somada com a tens o das fases R e T A influ ncia pequena em m dulo e grande em fase o que significa dizer que h uma boa compensa o para cargas reativas e uma pequena influ ncia mediante cargas ativas O transformador de corrente para compensa o de reativos dever estar na fase S do gerador e o sinal de realimenta o na fase R Para certificar a correta polariza o do TC deve ser aplicado cargas Resistivas Indutivas e verificar se o sistema responde conforme abaixo Cargas resistivas Com carga resistiva n o apresentar compensa o mantendo a corrente de excita o e tens o de gerador constante no valor ajustado via trimpot Vad Se houver compensa o indica que o TC est na fase errada Cargas Indutivas Com aplica o de cargas indutivas apresentar uma compensa o negativa diminuindo da corrente de excita o correspondendo ao ganho ajustado no trimpot droop 0 a 15 tens o ajustada no Vad Se a compensa o for positiva indica que o TC est invertido Cargas Capacitivas Com aplica o de cargas capacitivas apresentar uma compensa o positiva aumentando a corrente de excita o correspondendo ao ganho ajustado no trimpot droop 0 a 15 tens o ajustada no Vad Se a compens
6. Hz 45 50 54 60 30 Regulador Autom tico de Tension GRT7 TH4 www weg net ug 9 5 OPERACI N PARALELA DE DOS O M S GENERADORES El sistema de compensaci n de reactivos utilizado es denominado composici n fasorial vea fig 02 En este tipo de sistema cogiese el sinal de tensi n de salida del generador e se hace la composici n con el sinal de corriente del generador Lo que resulta de esta interacci n introduce un error en la regeneraci n del sinal real de tensi n provocando un aumento o una disminuci n en la tensi n del generador haciendo con que el reactivo entre los generadores se quede dentro de los valores aceptables El ajuste de esta compensaci n es hecho a trav s del trimpot P2 IS 1 Solamente en los modelos TH4 Seg n el gr fico la tensi n de regeneraci n sufre una influencia causada por la corriente de la fase S que es agregada con la tensi n de las fases R y T Esta influencia es peque a en m dulo y grande en fase o que significa decir que hay una buena compensaci n para cargas reactivas e una peque a influencia para las cargas activas El transformador de corriente para compensaci n de reactivos deber estar en la fase S del generador y el se al de regeneraci n en las fases R y T Para garantizar que la compensaci n est en sentido correcto proceda de la manera siguiente Accionar un generador sencillo aislado de la red aplicar una carga resistiva con cerca de 20 de la capacidad del
7. Tens o P2 Ajuste de faixa de comp de reativos Droop P3 Ajuste da Estabilidade 2 P4 Ajuste da Estabilidade 1 P5 Ajuste de Subfrequ ncia 8 AJUSTE DOS TRIMPOTS P1 Girando no sentido hor rio aumenta a tens o P2 Girando no sentido hor rio aumenta a faixa de compensa o de reativos P3 Girando no sentido hor rio a resposta torna se mais lenta P4 Girando no sentido hor rio a resposta torna se mais lenta P5 Girando no sentido hor rio aumenta a faixa de U F e anti hor rio diminui NOTE 1 Poder ser conectado potenci metro para ajuste fino de tens o 5k 1 SOMENTE NOS MODELOS TH4 E E TH4 PE 2 PRESENTE SOMENTE NOS MODELOS TH4 www weg net Campo de excita o Est gio de Pot ncia 3W nos bornes 6 e 7 Regulador Autom tico de Tens o GRT7 TH4 45 ug www weg net 9 OPERA O 9 1 REGULADOR DE TENS O Compara o valor real de tens o proveniente da sa da do gerador com o valor te rico ajustado atrav s do trimpot de ajuste de tens o P1 mais o ajuste externo de tens o caso houver O erro processado pela malha de realimenta o cujo valor determina o ngulo de disparo do tiristor que pode variar de O a 180 controlando desta forma a tens o de sa da do gerador 9 2 POTENCIA CONEX O DO CIRCUITO DE POT NCIA A tens o proveniente do gerador ou da bobina auxiliar conectada aos bornes 3 e E3 4 Esta tens o retificada aplicada control
8. causing an increase or a decrease in the generator voltage thus maintaining the reactive between the generators within acceptable values The adjustment of this compensation is made through trimpot P2 1 Only for models TH4 According to the phasor diagram the sensing voltage is influenced by the current coming from phase S which is added to the voltage of phases R and T The influence is small in module and large in phase which means that there is good compensation for reactive loads and a small influence with active loads The current transformer CT for reactive compensation must be in phase S of the generator and the voltage sensing signal must be in phases H and T To make sure the compensation is in the proper direction proceed as follows Operate the generator by itself isolated from the grid and apply a resistive load with about 20 of the generator capacity A After completely rotating the P2 trimpot clock wise CW the generator voltage should decrease Rotating back the trimpot completely CCW generator voltage should then increase If this occurs the CT polarity is correct Otherwise the CT should be inverted When several generators are connected in parallel this procedure is required to ensure that all the CT s are properly polarized The current transformer for compensation of reactive must be in phase S of the generator and the feeding signal in the phase R To ensure the correct polarization of TC Inductive Re
9. din micas Dotados de protecci n contra sub frecuencia su ponto de intervenci n es ajustable por trimpot y la frecuencia nominal de operaci n es configurable para 50 o 60Hz Regulador Autom tico de Tension GRT7 TH4 27 ug www weg net 4 CARACTER STICAS T CNICAS Modelo GRT7 GRT7 GRT7 TH4 GRT7 si si 160 300 o 320 600 Vca Veen 170 300 Vea 12 o 22 0 45 76 5 126 Vcc 6 hasta 500 0 5 8 hasta 500ms Frecuencia de operaci n Protecci n de sub frecuencia U F gama completa de tensi n Ajuste externo de tensi n Temperatura de operaci n Supresi n de EMI Peso aproximado 5 TARJETA DE IDENTIFICACI N Modelo Alimentaci n de Potencia de Excitaci n _ un 4 Frecuencia de md Operaci n Corriente Nominal Regeneraci n de Tensi n El ejemplo arriba muestra las principales caracter sticas que deben ser observadas antes de la instalaci n NOTE 1 La tarjeta de identificaci n se encuentra fijada en la parte inferior del regulador 1 Con tensi n de entrada en 170Vca en la salida resulta 76 5 Vcc Para 280Vca de tensi n de entrada resulta 126 Vcc de tensi n de salida o sea la m xima tensi n continua de salida es lo mismo que 0 45 x tensi n alternada de entrada 2 Recomendado el uso de multi vueltas del potenci metro 28 Regulador Autom tico de Tension GRT7 TH4 www weg net ug 6 DIAGRAMA DE BLOQUES Encendido
10. frontal a E3 4 Detalhe do furo de fixa o m 5 9 o m O e S E1 1276 F F 3 E34 uso gt 12 DESCRICAO DOS TERMINAIS DE CONEXAO E1 Realimenta o de tens o 160 a 300Vca E2 Realimentac o de tens o 320 a 600Vca 3 Alimenta o da pot ncia E3 4 Realimenta o de tens o 11 Conex o para p lo S1 do TC rela o In 5A 21 Conex o para p lo S2 do TC rela o In 5A 6 e 7 Conex o para potenci metro 5 k_1 3W F F Conex o para campo do gerador J1 Jumper 50 60 Hz J1 aberto 50 Hz fechado 60 Hz A2 Entrada anal gica de tens o 9 Vcc B2 Entrada anal gica de tens o 9 Vcc 1 Presente somente nos modelos TH4 2 Somente nos modelos TH4 E e TH4 PE 13 DIAGRAMA PARA TESTE SEM GERADOR Segue abaixo o diagrama para liga o do regulador em bancada onde pode ser verificado o funcionamento do equipamento antes de lig lo no gerador Material necess rio 1 Chave de fenda pequena 1 L mpada incandescente 1 Soquete para l mpada 1 disjuntor bipolar 5A recomendado 1 Cabo de extens o 1 Tomada 110V ou 220V Para tens o 110V selecionar jumper de realimenta o para classe A Para tens o 220V selecionar jumper de realimenta o para classe C NOTE v 1 Caso algum passo n o tenha ocorrido da maneira como descreve o procedimento o equipamento dever ser enviado para avalia
11. net 10 CONNECTION DIAGRAMS 10 1 CONNECTION FOR GENERATOR WITHOUT AUXILIARY COIL N Parallelism CT ratio In 5A P Generator P Sl S2 L E CY Y Y WW E Exciter Single parallel switch F field F E Open parallel Closed single Potentiometer for external voltage regulation 2 5kQ 3W Sensing Voltage of 160 up to 300Vac N Parallelism CT ratio In 5A R Generator P mam 2 T es I r Exciter p oaa field switch ale Tale IE Open parallel GRT7 TH 2 Potentiometer for A JT external voltage regulation 2 5kQ 3W Sensing Voltage of 320 up to 600Vac 16 Automatic Voltage Regulator GRT7 TH4 www weg net ug 10 2 CONNECTION FOR GENERATOR FITTED WITH AUXILIARY COIL N Parallelism CT ratio In 5A R Generator P P E S S2 was 1 CY Y Y WOW C F Exciter F Col E Single parallel field E switch Open parallel Closed single Potentiometer for external voltage regulation 2 BkO 3W Sensing Voltage of 160 up to 300Vac nn N Parallelism CT ratio In 5A Generator mamn E S S2 T ANN m t Coil 2 parallel F Exciter F C switch field Open parallel ETETS Jess 2 Closed single J GRT7 TH IE 6 A B 0 J1 Input 9V 3 Potentiomete r fo
12. o pela assist ncia t cnica GRAMEYER 50 Regulador Autom tico de Tens o GRT7 TH4 www weg net ug Montar circuito conforme diagrama ao lado 2 Com uma chave de fenda pequena girar os trimpot s Vad e U F no sentido anti hor rio at o fim de curso 3 Ligar o disjuntor 4 Girar levemente o trimpot Vad no sentido hor rio ap s uma determinada posi o do trimpot a lampada deve ascender 5 Com a l mpada acesa girar lentamente o trimpot Vad no sentido anti hor rio ap s uma determinada posi o do trimpot a l mpada deve apagar 6 Desligar disjuntor Realizados todos os passos conforme o procedimento o equipamento est funcionando normalmente Regulador Autom tico de Tens o GRT7 TH4 51 www weg net 14 DEFEITOS CAUSAS E SOLU ES Conectar a sequ ncia das fases corretamente Polarizar TC na fase corretamente conforme Sequ ncia das fases R S T abaixo conectados errados H circula o de reativos entre os geradores quando operando em paralelo TC conectado invertido Gerador S S Carga Ajuste do Droop muito baixo gt P P Aumentar o ajuste do Droop girando P2 para o sentido hor rio Queda na rota o da m quina Corrigir reg de velocidade Tens o gerada diminui quando aplicada 9 q p acionante aa eT HA Ajustar protec o de subfrequ ncia girando o Protec o de subfrequ ncia atuando trimpot P5 no sentido hor
13. on the bench where the equipment operation may be verified before connection to the generator Material required 1 Small screwdriver 1 Incandescent lamp 1 Lamp socket 1 Bipolar breaker 5A recommended 1 Extension cable 1 Plug 110V or 220V For voltage 110V select refeeding jumper class A For voltage 220V select refeeding jumper class C NOTE v 1 After performance of such steps as per the procedure the equipment must be sent for evaluation by GRAMEYER technical support 1 Mount circuit as per diagram below 2 With small screwdriver turn trimpots Vad and U F counter clockwise until the end of stroke 18 Automatic Voltage Regulator GRT7 TH4 www weg net ug Turn on circuit breaker Turn slightly the trimpot Vad clockwise the lamp must shine after certain position of trimpot With lamp on turn slightly the trimpot Vad counter clockwise after certain position of trimpot the lamp must turn off Turn off the circuit breaker um Automatic Voltage Regulator GRT7 TH4 19 ug www weg net 14 PROBLEMS CAUSES AND CORRECTIVE ACTIONS Connect phase sequence correctly Correctly polarize the CT in the phase shown below Phases sequence R S T incorrectly connected There is circulation of reactive power Conrat S S Load between generators when operating in I 9 9 CT connections inverted parallel gt Droop adjustment e
14. opera o configur vel para 50 ou 60 Hz Regulador Autom tico de Tens o GRT7 TH4 43 ug www weg net 4 CARACTER STICAS T CNICAS Modelo GRT7 GRT7 GRT7 TH4 GRT7 Corrente nominal de operac o Corrente de pico Entrada anal gica 9Vcc 0 45 Alimenta o da pot ncia 170 300 Vca 14 ou 22 Frequ ncia de opera o Prote o de subfrequencia U F Ajuste interno de tens o Ajuste externo de tens o 30 Vsen Temperatura de opera o Supress o de EMI Peso aproximado 5 ETIQUETA DE IDENTIFICA O Modelo Alimenta o b da Pot ncia E Tens o de Excita o lu SIE Corrente Nominal _ Frequ ncia de m d Opera o Realimenta o de Tens o O exemplo acima mostra as principais caracter sticas a serem observadas antes da instala o NOTE 1 A etiqueta de identifica o encontra se fixada na parte inferior do regulador Com tens o de entrada em 170Vca obt m se 76 5Vcc de tens o m xima de sa da Para 280Vca de tens o de entrada obt m se 126 Vcc de tens o de sa da ou seja a m xima tens o cont nua de sa da igual a 0 45 x tens o alternada de entrada 44 Regulador Autom tico de Tens o GRT7 TH4 6 DIAGRAMA DE BLOCOS Valor de referencia Escorvamento autom tico 7 Entrada anal gica 9 Vcc A U F Realimenta o DROOP 2 7 FUN O DOS TRIMPOTS P1 Ajuste de
15. separado y caso fuera necesario informaciones adicion is sobre el producto Las solicitaciones podr n ser atendidas siempre que sea informado el n mero de serie y modelo del equipo ATENCI N 1 Es imprescindible seguir los procedimientos contenidos en este manual para que la garant a tenga validez 2 Los procedimientos de instalaci n operaci n y mantenimiento del generador deber n hacerse por personal calificado NOTAS 1 La reproducci n de las informaciones de este manual total o en partes se permite desde que la fuente sea citada 2 Si se extraviar este manual el archivo electr nico en formato PDF est disponible en el sitio www weg net o podr ser solicitada otra copia impresa Regulador Autom tico de Tension GRT7 TH4 23 N QQ G A W 10 11 12 13 14 15 16 www weg net ug INDEX INFORMACIONES DE SEGURIDAD rennen nhe 27 INFORMACIONES SOBRE 27 INTRODUCCI N PAM 27 CARACTER STICAS TECNICAS cccccsscccsteccsscecestcecsescccsenecessuscsneceseneceeuecesauecsuneeecseneneees 28 TARJETA DE IDENTIFICACI N eere nennen narco none nnnnn rn nnnn nn rear 28 DIAGRAMA DE BLOQUES ccsssccesceceeccccstcccsescecseseccctcccsateceuseucsnecesuseceusecsenececseneeeeanes 29 FUNCI N DE LOS TRIMPOTS cc ccsscccosscccsecccesescecsescccsetcecstscsencecsenec
16. ser observados os manuais de instru o e a etiqueta de identifica o do produto antes de proceder a sua instala o manuseio e parametriza o Dever o ser tomadas as devidas precau es contra quedas choques f sicos e ou riscos seguran a dos operadores e do equipamento Sempre desconecte a alimenta o geral e aguarde a parada total do gerador antes de tocar em qualquer componente el trico associado ao equipamento isto inclui tamb m os conectores de comandos N o toque nos conectores de entradas e sa das pois altas tens es podem estar presentes mesmo ap s a desconex o da alimenta o e mantenha os sempre isolados do restante do circuito de comando principal do gerador 2 INFORMA ES SOBRE ARMAZENAMENTO Em caso de necessidade de armazenagem do regulador por um breve per odo de tempo que anteceda a sua instala o e ou coloca o em funcionamento dever o ser tomadas as seguintes precau es Oregulador dever ser mantido na sua embalagem original ou embalagem que satisfa a as mesmas condi es de seguran a contra danos mec nicos temperatura e umidade excessivas para prevenir a ocorr ncia de oxida o de contatos e partes met licas danos a circuitos integrados ou outros danos provenientes da m conserva o O regulador devidamente acondicionado dever ser abrigado em local seco ventilado em que n o ocorra a incid ncia direta dos raios solares bem como a chuva vento e outras intemp ries par
17. terminal and connections are kept free from corrosion 16 WARRANTY See Installation and Maintenance Manual for WEG G Line Generator WEG Equipamentos El tricos S A International Division Av Prefeito Waldemar Grubba 3000 89256 900 Jaragu do Sul SC Brazil Phone 55 47 3276 4002 Fax 55 47 3276 4060 WWW Weg net 20 Automatic Voltage Regulator GRT7 TH4 www weg net NOTES Automatic Voltage Regulator GRT7 TH4 21 ug WWW Weg net 22 Automatic Voltage Regulator GRT7 TH4 www weg net PREFACIO Esta publicaci n no podr en ninguna hip tesis ser reproducida almacenada o transmitida a trav s de alg n tipo de medio sea electr nico impreso fonogr fico o qualquier otro posible medio audiovisual sin la autorizaci n pr via de WEG Ind strias S A Los infractores estar n sujetos a las penas previstas en la ley Esta publicaci n podr ser alterada y o actualizada y podr n resultar en nuevas revisiones de los manuales de instalaci n operaci n y mantenimiento teniendo en vista el cont nuo perfeccionamiento de los productos WEG La WEG se reserva el derecho de la no obligatoriedad de actualizaci n autom tica de las informaciones contenidas en estas nuevas revisiones No obstante eso y en cualquier momento el cliente podr solicitar material actualizado que le ser provisto sin cargos resultantes En caso de perdida del manual de instrucciones la WEG podr proveer ejemplar
18. value 6 Analog input E 9 Vdc 1 4 U F Sensing DROOP 2 7 TRIMPOTS FUNCTION P1 Voltage adjustment P2 Droop adjustment P3 Stability 2 adjustment P4 Stability 1 adjustment P5 Under frequency adjustment 8 TRIMPOTS ADJUSTMENT P1 Rotating CW voltage increases P2 Rotating CW reactive compensation range increases P3 Rotating CW dynamic response will be slower P4 Rotating CW dynamic response will be slower P5 Rotating CW U F range increases and rotating CCW it decreases NOTE v 1 A potentiometer may be connected for fine voltage adjustment 5 3 W at terminals 6 and 7 Only for models TH4 E and TH4 PE 2 Available only for models TH4 Automatic Voltage Regulator GRT7 TH4 13 ug www weg net 9 OPERATION 9 1 VOLTAGE REGULATOR It compares the actual output voltage from the generator with the theoretical adjusted value through the trimpot of voltage adjustment P1 plus the external voltage adjustment if any The error is processed by the sensing loop whose value determines the thyristor firing angle which may vary from O to 180 thus controlling the output voltage of the generator 9 2 POWER CIRCUIT CONNECTION The generator voltage or the auxiliary winding voltage is connected to the terminals 3 and E3 4 This rectified voltage is applied in a controlled fashion to the generator exciter field 9 3 FIELD FLASHING Generation begins through
19. x Campo de excitaci n de campo D Etapa de potencia autom tico Valor de referencia 7 Entrada anal gica MEME 9 Vcc 1 A U F Regeneraci n DROOP 2 7 FUNCI N DE LOS TRIMPOTS P1 Ajuste de Tensi n P2 Ajuste del rango de comp de reactivos Droop P3 Ajuste da Estabilidad 2 P4 Ajuste da Estabilidad 1 P5 Ajuste de Bajo frecuencia 8 AJUSTE DE LOS TRIMPOTS P1 Girando en el sentido horario aumenta la tensi n P2 Girando en el sentido horario aumenta la faja de compensaci n de reactivos P3 Girando en el sentido horario la respuesta se hace m s lenta P4 Girando en el sentido horario la respuesta se hace m s lenta P5 Girando en el sentido horario aumenta la faja de U F y antihorario diminuye NOTE v 1 Podr ser conectado potenci metro para ajuste fino de tensi n 5k 3W en los bornes 6 y 7 1 SOLAMENTE EN LOS MODELOS TH4 E Y TH4 PE 2 PRESENTE SOLAMENTE EN LOS MODELOS TH4 Regulador Autom tico de Tension GRT7 TH4 29 ug www weg net 9 OPERACION 9 1 REGULADOR DE TENSI N Compara el valor real de tensi n del generador con el valor te rico ajustado a trav s del trimpot de ajuste de tensi n P1 m s el ajuste externo de tensi n caso poseyera El error se procesa por la malla de regeneraci n por lo cual el valor determina el ngulo de gatillo del thiristor que pode variar de O hasta 180 controlando as la
20. MANTENIMIENTO PREVENTIVO Es necesario proceder se inspecciones peri dicas en la unidad para asegurarse de que la misma encontrase limpia y libre de las acumulaciones de polvo y otros detritos Es vital que todos los terminales y conexiones de los cables sean mantenidos libres de corrosi n 16 GARANTIA Vea el Manual de Instalaci n y Mantenimiento del Generador Weg L nea G WEG Equipamentos El tricos S A International Division Av Prefeito Waldemar Grubba 3000 89256 900 Jaragu do Sul SC Brazil Phone 55 47 3276 4002 Fax 55 47 3276 4060 www weg net 36 Regulador Autom tico de Tension GRT7 TH4 www weg net ug NOTAS Regulador Autom tico de Tension GRT7 TH4 37 ug www weg net 38 Regulador Autom tico de Tension GRT7 TH4 www weg net ug PREFACIO Esta publicac o n o poder em hip tese alguma ser reproduzida armazenada ou transmitida atrav s de nenhum tipo de m dia seja eletr nica impressa fonogr fica ou qualquer outro meio audiovisual sem a pr via autorizac o da WEG Os infratores estar o sujeitos s penalidades previstas em lei Esta publica o est sujeita a altera es e ou atualiza es que poder o resultar em novas revis es dos manuais de instala o e opera o tendo em vista o cont nuo aperfei oamento dos produtos WEG A WEG se reserva o direito da n o obrigatoriedade de atualiza o autom tica das informa es contidas nestas novas revis es Contudo
21. Motors Automation Energy Transmission amp Distribution Coatings Automatic Voltage Regulator Regulador Autom tico de Tensi n Regulador Autom tico de Tens o T Z et y e 5 Ty g B g DM E Ses E FE SaaS y 4 g mum B LI atq EE sme j i d Installation Operation and Maintenance Manual Manual de Instalaci n Operaci n y Mantenimiento Manual de Instala o Opera o e Manuten o Installation Operation and Maintenance Manual Manual de Instalaci n Operaci n y Mantenimiento Manual de Instala o Opera o e Manuten o Document N do documento 10040217 Models Modelos GRT7 TH4 GRT7 THA P GRT7 TH4 E GRT7 TH4 PE GRT7 TH5 Language Idioma English Espa ol Portugu s Revision Revisi n Revis o 06 April Abril Abril 2014 GENERAL INDEX NDICE GENERAL NDICE GERAL Installation Operation and Maintenance Manual Page 7 22 Manual de Instalaci n Operaci n y Mantenimiento P ginas 23 38 Manual de Instala o Opera o e Manuten o P ginas 39 53 Portugu s www weg net ug FOREWORD This manual may in no way be reproduced filed or transmitted through any type of media whether it be electronically by printing phonographically or any other audiovisual means without prior cons
22. S Ener ne 12 REGULATOR NANMEPLAIE u u u eat 12 BLOCK DIAGER AM u 19 jet regem 13 TRIMPOTS ADJUSTMENT uuu 19 OPERATION sas u uum 14 9 1 VOLTAGE REGULATOR 14 9 2 POWER CIRCUIT CONNECTION u 14 9 3 PELO ELA SIN su u dE TS AS nen saan 14 9 4 O P P Al l u ere 14 9 5 PARALLEL OPERATION FOR TWO OR MORE 5 15 CONNECTION DIAGBAMOS ss nee 16 10 1 CONNECTION FOR GENERATOR WITHOUT AUXILIARY COIL 16 10 2 CONNECTION FOR GENERATOR FITTED WITH AUXILIARY COIL nn 17 DIMENSIONAL DRAWINGS MM au uu 18 IDENTIFICATION OF CONNECTION TERMINALS U J 18 DIAGRAM FOR TEST WITHOUT GENERATOR can an 18 PROBLEMS CAUSES AND CORRECTIVE ACTION S 20 PREVENTIVE MAINTENANCE een ee nei 20 VP ee 20 Automatic Voltage Regulator GR
23. T7 TH4 9 www weg net 1 SAFETY INFORMATION To guarantee the safety of the operators the correct installation and proper operation of the equipment the following precautions must be taken Installation and maintenance services should be performed only by qualified personnel using appropriate equipment The product instruction manual and specific product documentation must always be consulted before proceeding with its installation handling and parameter setting Adequate precautions should be taken to avoid drops knocks and or risks to the operators and the equipment Always disconnect the main power supply and wait for the generator to come to a complete stop before touching any electrical component associated with the equipment including the control connectors Do not touch the input and output connectors since high voltages may be present even after the power has been switched off and keep them isolated from the rest of the main command circuit of the generator 2 STORAGE INFORMATION If the generator needs to be stored for a short period of time before its installation and or start up the following measures should be taken regulator must remain in its original package or in a similar package which provides the same safety conditions against mechanical damages excessive temperature and humidity so as to avoid rusting of contacts and metallic parts damages to integrated circuits or any other damage arising
24. TS U nenne nee 45 46 9 1 REGULADOR DE TENS O Po Pe 46 9 2 POTENCIA CONEXAO DO CIRCUITO 46 9 3 e O i SE O A 46 9 4 Sic a ted eo 46 9 5 OPERA O PARALELA DE DOIS OU MAIS GERADORES a nass 47 DIAGRAMA DE CONEXAO uuu ee ee 48 10 1 CONEX O DO GERADOR SEM BOBINA AUXILIAR u aa 48 10 2 CONEXAO DO GERADOR COM BOBINA AUXILIAR esee nmn 49 MER 50 DESCRI O DOS TERMINAIS DE CONEXAQO U uuu u uuu 50 DIAGRAMA PARA TESTE SEM GERADOR I 50 DEFEITOS CAUSAS E SOLUC OES U uu 52 MANUTEN O PREVENTINA I u u u u 52 GARANTIA uu u c 52 Regulador Autom tico de Tens o GRT7 TH4 41 www weg net ug 1 INFORMACOES DE SEGURANCA Para garantir a seguranca dos operadores a correta instalac o do equipamento e sua preservac o as seguintes precauc es dever o ser tomadas Os servi os de instala o e manuten o dever o ser executados somente por pessoas qualificadas e com a utiliza o dos equipamentos apropriados Dever o sempre
25. The under frequency protection set point is adjustable by trimpot and the nominal operating frequency can be set to 50Hz or 60Hz Automatic Voltage Regulator GRT7 TH4 11 Weg www weg net 4 TECHNICAL CHARACTERISTICS Model Characteristics Nominal operating current GRT7 GRT7 GRT7 TH4 GRT7 GRT7 TH4 rp THE PE TH5 Droop adjustment for parallel operation 0 45 Adjustable dynamic response Operating frequency Under Frequency protection U F Internal voltage adjustment Adjustable via trimpot for the complete range of Voltage External voltage adjustment 9096 Vsen Operating Temperature EMI suppression Approximate weight 5 REGULATOR NAMEPLATE Model Power Supply Excitation Voltage k gt Rated Current _ The example above shows the main characteristics to be followed before installation Operating Frequency di Sensing Voltage NOTE 1 The identification nameplate is attached to the bottom of the regulator frame 1 For an input voltage of 170Vac the maximum output voltage obtained is 76 5Vdc For 280Vac of input voltage the output voltage obtained is 126Vdc that is the maximum dc output voltage is equal to 0 45 x the ac voltage input Recommended the use of multi turn potentiometer 12 Automatic Voltage Regulator GRT7 TH4 www weg net ug 6 BLOCK DIAGRAM p Excitatiorfield Automatic D Power stage field flashing Reference
26. a o for negativa indica que o TC est invertido Regulador Autom tico de Tens o GRI7 TH4 47 www weg net Classe de exatid o de 0 6C12 5 Tipo janela ou barra A rela o de transforma o ser In 5A ou In 1A onde In xA a rela o do prim rio do TC Ex 100 5A 150 5A 100 1A Corrente de secund rio de 5A para regulador PAR 5 e 1A para regulador PAR 1 A corrente no prim rio do TC deve ser 20 maior do que a corrente nominal da maquina Afrequ ncia de trabalho do TC deve ser igual frequ ncia do gerador A classe de tens o de isola o do TC dever ser maior do que a tens o de sa da do gerador Dever suportar 1 2 x In 10 DIAGRAMA DE CONEX O 10 1 CONEX O DO GERADOR SEM BOBINA AUXILIAR TC de paralelismo rela o In 5A Gerador Campo Aberta paralelo F da F am excitatriz Fechada singelo E T CY MY WWW u Chave singelo paralelo Entrada 9V 3 EAE Potenci metro de ajuste externo de tens o 2 5kQ 3W Tens o de realimentac o de 160 at 300Vca N TC de paralelismo rela o In 5A Gerador UN C ampo Aberta paralelo da F ar excitatriz Fechada singelo NENNEN E 1 2 Chave singelo paralelo tens o 2 5k0 3W Entrada 9V 3 Potenci metro de ajuste externo de Tens o de realimenta o de 320 at 600Vca 48 Regulador Auto
27. a garantir a manuten o de suas caracter sticas funcionais A n o observ ncia das recomenda es acima poder eximir a empresa fornecedora do equipamento de quaisquer responsabilidades pelos danos decorrentes bem como a perda da garantia sobre o equipamento ou parte danificada 3 INTRODU O Os reguladores eletr nicos de tens o anal gicos da s rie GRT7 s o equipamentos compactos de alta confiabilidade e de baixo custo os quais foram desenvolvidos dentro da mais alta tecnologia para regula o de tens o em geradores s ncronos sem escovas brushless Seu circuito de controle e regula o utiliza semicondutores e circuitos integrados testados dentro dos mais r gidos padr es de qualidade N o possui componentes mec nicos para escorvamento e seu sistema totalmente est tico e encapsulado em resina ep xi resistente maresia apto a suportar vibra es de at 50mm s Possui ajuste de tens o interno via trimpot e externo via potenci metro possibilitando uma faixa de ajuste da tens o do gerador em 15 da tens o nominal Seu sistema de controle PID ajustado atrav s de trimpots que ajustam o ganho proporcional e o ganho integral possibilitando uma ampla faixa de ajuste o que permite opera o com os mais diversos tipos de geradores e com as mais variadas caracter sticas din micas Dotado de prote o contra subfrequ ncia seu ponto de interven o ajust vel via trimpot e a frequ ncia nominal de
28. adamente ao campo da excitatriz do gerador 9 3 ESCORVAMENTO O in cio de gera o se d atrav s da tens o residual do gerador Ap s a tens o atingir aproximadamente 10 da nominal o regulador controla a tens o do gerador fazendo com que a tens o suba atrav s da rampa inicial em aproximadamente 3 segundos at atingir a tens o nominal A partir deste momento a malha de controle do PID manter a tens o de sa da do gerador constante dentro do valor ajustado 9 4 OPERA O U F Este modo de opera o determinado pelo trimpot P5 jumper J1 e componentes associados O jumper J1 determina a frequ ncia de opera o que segue a seguinte l gica J1fechado 60Hz J1 aberto 50Hz O trimpot P5 determina o ponto de atua o do modo U F que pode ser desde a frequ ncia nominal Fn at 1 3 de Fn cujo valor sai ajustado de f brica 10 abaixo da Fn Para opera o em 60Hz ajustado para 54Hz e para opera o em 50Hz ajustado para 45Hz ver fig 1 cujo valor pode ser alterado de acordo com a necessidade de cada aplica o o o O U ah U o o S Q o bd Frequ ncia Hz Frequ ncia Hz 45 50 54 Bg er 46 Regulador Autom tico de Tens o GRT7 TH4 www weg net ug 9 5 OPERA O PARALELA DE DOIS OU MAIS GERADORES O sistema de compensa o de reativos adotado denominado composi o fasorial ver fig 02 Neste tipo de sistema toma se o sinal de tens o de sa da do g
29. ajo EEEM P P Aumentar el ajuste del Droop girando el potenci metro P2 en sentido horario Ca da en la rotaci n de la m quina Corrija reg de velocidad Tensi n generada diminuye cuando propulsora aplicada carga y no retorna Ajuste la protecci n de sub frecuencia Protecci n de bajo frecuencia actuando girando el trimpot P5 en sentido horario Con el regulador conectado usar una bater a externa 12Vcc para reforzar la excitaci n 7 Generador no enciende Bornes F e F invertidos Inverter F e F Din mica desajustada Ajustar los trimpot s P3 y P4 Tensi n generada oscila en vac o Tensi n de excitaci n del generador Instalar un resistor 10 100W en serie con el muy peque a campo Eliminar el bobinado auxiliar y hacer la conexi n conforme los diagramas de la pagina 13 Tensi n oscila en punto de carga Tercera harm nica del bobinado auxiliar espec fico muy elevada Perdida de regeneraci n 9 Verificar si las fases del generador est n Circuito electr nico con defecto presentes en la regeneraci n Tensi n dispara I Para regulador encapsulado efectuar el Tensi n de regeneraci n incompatible 9 p cambio de lo mismo con el regulador En caso de tratarse de grupo generador Diesel deber siempre ser utilizada bater a independiente donde el neutro del generador estuvier aterrad 15
30. ci n deber n ser hechos solamente por personas calificadas y con manejo de los equipos correctos Deber n siempre ser observados los manuales de instrucci n y la tarjeta de identificaci n del producto antes de proceder su instalaci n manejo y configuraci n Debiese tener especial cuidado para que el equipo no sufra ca das golpes f sicos y o poniendo en riesgo la seguridad de las personas a Siempre desconecte la red general y aguarde hasta la parada total del generador antes de tocar en cualquier componente el ctrico asociado al equipo haciendo tambi n lo mismo en los terminales de comando No toque en los conectadores de entradas y salidas porque altas tensiones pueden estar presentes mismo despu s de la desconexi n de la red y mantenga estos siempre aislados de lo restante del circuito de comando principal del generador 2 INFORMACIONES SOBRE ALMACENAJE En caso de necesidad de almacenaje del regulador por peque o per odo de tiempo antes de su instalaci n y o funcionamiento deber n ser tomadas las precauciones como sigue Elregulador deber ser mantenido en su embalaje original o embalaje que atienda las mismas condiciones de seguridad contra da os mec nicos temperatura y humedad excesivas para prevenir la ocurrencia de oxidaci n de conexiones contactos y partes met licas da os en circuitos integrados o otros da os provenientes de mala conservaci n El regulador debidamente acondicionado deber
31. csuscesececseneueeseneneeanes 29 AJUSTE DE LOS TRIMPOTS cccccsssccceccccesscecsesececsescceseuecesereccuecesneuecuscesuecauseeceeenseeeneess 29 OPERACI N 30 9 1 REGULADOR DE TENSI N RR 30 9 2 CONEXI N DEL CIRCUITO DE POTENCIA nn 30 9 3 _ ENCENDIDO DEL CAMPO cnn anne 30 9 OPERACI N U F aan aaa 30 9 5 OPERACI N PARALELA DE DOS O M S GENERADORESL een 31 DIAGRAMA DE CONEXION cccccssccccssceceecccessceccsescecsercucsereccsucecsuscucsansecsensecesenesenececseneeeeanes 32 10 1 CONEXI N DEL GENERADOR SIN BOBINADO AUXILIAR nen 32 10 2 CONEXI N DEL GENERADOR CON BOBINA AUXILIAR 33 DIMENSIONAL 34 DESCRIPCI N DE LOS TERMINALES DE CONEXI N eere 34 DIAGRAMA PARA PRUEBA SIN GENERADOR 34 DEFECTOS CAUSAS Y SOLUCIONES reais 36 1 36 VM 36 Regulador Autom tico de Tension GRT7 TH4 25 www weg net 1 INFORMACIONES DE SEGURIDAD Para garantizar la seguridad de los operadores la correcta instalaci n del equipo y su preservaci n las precauciones abajo deber n ser tomadas Los servicios de Instalaci n y manuten
32. dela F excitatriz errada aislado Potenciom tro de Entrada 9V 3 tensi n 2 ajuste externo de 5k0 3W Tensi n de realimentaci n de 320 hasta 600Vca 32 Regulador Autom tico de Tension GRT7 TH4 www weg net ug 10 2 CONEXI N DEL GENERADOR CON BOBINA AUXILIAR N TC de paralelismo relaci n In 5A Generador mam P S2 T 0055502 Bobina E AS 4 r Campo AUX Liave Aislado paralelo Abieria paralelo de la Excitatriz esa 1 Cerrada aislado 4 GRI7 TH E Entrada OV Jl Potenci metro de ajuste externo de tensi n 2 5kQ 3W Tensi n de realimentaci n de 160 hasta 300Vca N TC de paralelismo relaci n In 5A R Generador P P S S2 e E Bobina u To Aislado paralelo F E Abierta paralelo E Cerrada aislado Potenci metro de ajuste externo de tensi n 12 5k0 3W Tensi n de realimentaci n de 320 hasta 600Vca 1 COMPONENTE NO FORNECIDO POR WEG 2 SI NO POSEYERE POTENCI METRO CONECTADO MANTENER LOS TERMINALES 6 Y 7 CONECTADOS CORTOCIRCUITADOS 3 SOLAMENTE EN LOS MODELOS TH4 E y TH4 PE ATENCI N Antes de conectar el regulador al generador verifique en el manual de instalaci n la tensi n nominal de referencia Caso la tensi n de refer
33. encia no sea igual a tensi n de salida del generador no efectuar las conexiones sin antes consultar la asistencia t cnica de Weg Regulador Autom tico de Tension GRT7 TH4 33 www weg net 11 DIMENSIONAL mm Vista Superior Vista delantera a E3 4 Detalle del agujero de fijaci n ITI zy o Q w w D o fen o E1 1276 F F 3 E34 1450 ss 12 DESCRIPCI N DE LOS TERMINALES DE CONEXI N E1 Regeneraci n de tensi n 160 a 300Vca E2 Regeneraci n de tensi n 320 a 600Vca 3 Alimentaci n de potencia E3 4 Regeneraci n de tensi n 11 Conexi n para polo S1 del TC relaci n In 5A 21 Conexi n para polo S2 del TC relaci n In 5A 6 e 7 Conexi n para potenci metro 5 F F Conexi n para campo del generador J1 Jump 50 60 Hz J1 abierto 50 Hz cerrado 60 Hz A Entrada anal gica de tensi n 9 Vcc B Entrada anal gica de tensi n 9 Vcc 1 SOLAMENTE EN LOS MODELOS TH4 2 SOLAMENTE EN LOS MODELOS TH4 E v TH4 PE 13 DIAGRAMA PARA PRUEBA SIN GENERADOR A continuaci n el diagrama para conexi n del regulador en el banco de pruebas donde puede verificarse el funcionamiento del equipo antes de conectarlo al generador Material necesario 1 Destornillador peque o 1 L mpara incandescente 1 Soquete para l mpara 1 disyuntor bipolar 5A recomendado 1 Cable de extensi n 1 Tomacorrie
34. ent from WEG Infringement is subject to prosecution under the law Due to the continuous improvement of WEG products the present manual may be modified and or updated without prior notice which may result in new revisions of the installation and maintenance manuals for the same product WEG reserves itself the right not to update automatically the information included in this manual However customers may at any time request any updated version of the manual which will be supplied to them free of charge If requested WEG can supply an extra copy of this manual The equipment serial number and model should be informed by the customer when making the request ATTENTION 1 It is absolutely necessary to follow the procedures contained in this manual for the warranty to be valid 2 The generator installation operation and maintenance must be executed by qualified personnel NOTES 1 The total or partial reproduction of the information supplied in this manual is authorized provided that reference is made to its source 2 If this manual is lost an electronic PDF file is available from our website www weg net or another printed copy can be requested Automatic Voltage Regulator GRT7 TH4 7 ON FP G Na 10 11 12 13 14 15 16 www weg net ug INDEX SAFETY INFORMAIIDNuu u uu 11 STORAGE INFORMATION us 11 INTRODUC TION 11 TECHNICAL CHARACTIERISTIO
35. erador e faz se a composi o com o sinal de corrente do gerador O resultado desta intera o introduz um erro na realimenta o do sinal real de tens o provocando um aumento ou uma diminui o na tens o do gerador fazendo com que o reativo entre os geradores fique dentro dos valores aceit veis O ajuste desta compensa o feito atrav s do trimpot P2 IS 1 Somente nos modelos TH4 Conforme o diagrama fasorial a tens o de realimenta o sofre uma influ ncia provocada pela corrente proveniente da fase S que somada com a tens o das fases R e T A influ ncia pequena em m dulo e grande em fase o que significa dizer que h uma boa compensa o para cargas reativas e uma pequena influ ncia mediante cargas ativas O transformador de corrente para compensa o de reativos dever estar na fase S do gerador e o sinal de realimenta o nas fases Re T Para certificar se que a compensa o est no sentido correto proceder da seguinte forma Acionar o gerador de forma singela isolado da rede aplicar uma carga resistiva da ordem de 20 de sua capacidade Ap s girar o trimpot P2 todo no sentido hor rio neste processo deve ocorrer uma queda de tens o no gerador Voltando o trimpot novamente para a posi o anti hor rio a tens o dever aumentar Se isto acontecer a polaridade do TC est correta caso contr rio o TC dever ser invertido Quando liga se v rias m quinas em paralelo este procedimento necess
36. from improper storage Properly packaged the regulator must be kept in a dry and well ventilated area away from direct sunlight rain wind and other adverse weather conditions in order to ensure the preservation of its operational functions Failure to comply with the above mentioned recommendations could exempt the supplier of the equipment from any responsibilities and liabilities from any resulting damages as well as voiding the warranty on the equipment or damaged part 3 INTRODUCTION The GRT7 automatic analog voltage regulators are compact while featuring high reliability and low cost They were designed with state of the art technology for voltage regulation of brushless synchronous generators Their control and regulation circuits use semiconductors and integrated circuits duly tested following the most demanding quality requirements Mechanical components for field flashing are not required and its system is completely solid state and encapsulated in epoxy resin suitable for maritime environments and able to withstand vibrations of up to 50 mm s It is fitted with internal voltage adjustment by trimpot and external by potentiometer allowing a generator voltage adjustment The PID control system is adjusted with two trimpots that adjust the proportional gain and the integral gain allowing a wide adjustment range while allowing operation of the regulator with several types of generators and with a high number of dynamic characteristics
37. m tico de Tens o GRT7 TH4 www weg net ug 10 2 CONEX O DO GERADOR COM BOBINA AUXILIAR nn TC de paralelismo rela o In 5A Gerador P P S2 Bi Bobin r Campo 2 s Chave singelo paralelo da Aberta paralelo Fechada excitatriz El 2 3 1 12 singelo GRT7 TH 2 Entrada OV JI Potenci metro de ajuste externo de Loo tens o 2 5kQ 3W Tens o de realimentac o de 160 at 300Vca N TC de paralelismo rela o In 5A R Gerador P P S S2 _ E I CY OCA tp bi u solle s Chave singelo paralelo r Campo rs A ds berta paralelo excitatriz Fechada singelo Potenci metro de ajuste externo de tens o 2 5kQ 3W Tens o de realimentac o de 320 at 600Vca 1 ITEM N O FORNECIDO PELA WEG 2 SE N O HOUVER POTENCI METRO CONECTADO MANTER OS TERMINAIS 6 E 7 JUMPEADOS CURTO CIRCUITADOS 3 PRESENTE SOMENTE NOS MODELOS TH4 E E TH4 PE ATEN O 1 Antes de conectar o regulador ao gerador verifique no manual de instala o a tens o nominal de refer ncia Se a tens o de refer ncia n o for igual a tens o de sa da do gerador n o efetuar as liga es sem antes consultar a assist ncia t cnica Regulador Autom tico de Tens o GRT7 TH4 49 www weg net 11 DIMENSIONAL mm Vista Superior Vista
38. nte 110V 220V Para tensi n 110V seleccione el jumper de realimentaci n para clase A Para tensi n 220V seleccione el jumper de realimentaci n para clase C NOTE 1 Si alg n paso no ha ocurrido de la manera como describe el procedimiento se debe enviar el equipo para evaluaci n por la asistencia t cnica GRAMEYER 34 Regulador Autom tico de Tension GRT7 TH4 www weg net ug Monte el circuito conforme el diagrama al lado 2 Con un destornillador peque o gire los trimpot s Vad y U F en sentido antihorario hasta el tope final 3 Conecte el disyuntor 4 Gire ligeramente el trimpot Vad en sentido horario despu s de una determinada posici n del trimpot la l mpara debe encender 5 Con la l mpara encendida gire lentamente el trimpot Vad en sentido antihorario despu s de una determinada posici n del trimpot la l mpara debe apagarse 6 Desconecte el disyuntor Realizados todos los pasos conforme el procedimiento el equipo est funcionando normalmente Regulador Autom tico de Tension GRT7 TH4 35 www weg net 14 DEFECTOS CAUSAS Y SOLUCIONES Conectar la secuencia de las fases correctamente Polarizar el TC en la fase correctamente Secuencia incorrecta de las fases R S conforme abajo T Hay circulaci n de reactivos entre los S S generadores cuando operando en paralelo TC conectado invertido Generador Carga Ajuste del Droop muy b
39. presentar una compensaci n positiva aumentando la corriente de excitaci n correspondiendo a la ganancia ajustado en el trimpot droop del O al 1596 tensi n ajustada en el Vad Si la compensaci n es negativa indica que el TC est invertido A Clase de exactitud de 0 6C12 5 ventana o barra Regulador Autom tico de Tension GRT7 TH4 31 ug www weg net Larelaci n de transformaci n ser In 5A o In 1A donde In xA es la relaci n del primario del TC Ej 100 5A 150 5A 100 1A Corriente de secundario de 5A para regulador PAR 5 y 1A para regulador PAR 1 Lacorriente en el primario del TC debe ser el 20 mayor que la corriente nominal de la m quina afrecuencia de trabajo del TC debe ser igual a la frecuencia del generador aclase de tensi n de aislaci n del TC deber ser mayor que la tensi n de salida del generador Deber soportar 1 2 x In 10 DIAGRAMA DE CONEXI N 10 14 CONEXI N DEL GENERADOR SIN BOBINADO AUXILIAR N TC de paralelismo relaci n In 5 P Generador P Sl w B T CY Y Y MW E Campo i Liave Aislado paralelo S2 F de la F Abierta paralelo excitatriz Cerrada aislado Entrada 9V 3 ll EE Potenciom tro de ajuste externo de tensi n 2 5KQ 3W Tensi n de realimentaci n de 160 hasta 300Vca TC de paralelismo relaci n In 5 Generador E l pP T DDD Campo E 2 Liave Aislado paralelo F
40. r external voltage regulation 5k0 3W Sensing Voltage of 320 up to 600Vac 1 ITEM NOT SUPPLIED BY WEG 2 IF NO POTENTIOMETER IS CONNECTED KEEP TERMINALS 6 AND 7 JUMPED SHORT CIRCUITED 3 AVAILABLE ONLY FOR MODELS TH4 E AND THA ATTENTION Before connecting the regulator to the generator check installation manual and the nominal reference voltage If the reference voltage is not equal to the generator output voltage do not make the connections without first contacting the service department Automatic Voltage Regulator GRT7 TH4 17 www weg net 11 DIMENSIONAL DRAWINGS mm Overview Front view a E3 4 Fixing hole detail m zy o Q w w D o fen o E1 1276 F F 3 E34 1450 12 IDENTIFICATION OF CONNECTION TERMINALS E1 Sensing Voltage 160 up to 300Vac E2 Voltage 320 up to 600Vca 3 Power supply E3 4 Sensing Voltage 11 Connection for pole S1 of the CT ratio In 5A 21 Connection for pole S2 of the CT ratio In 5 6 e 7 Connection for potentiometer 5KLI 3W F F Connection for generator field J1 Jumper 50 60Hz 91 open 50Hz closed 60Hz A Analog input voltage 9 Vdc B Analog input voltage 9 Vdc 1 Available only for models TH4 2 Only for models TH4 E and TH4 PE 13 DIAGRAM FOR TEST WITHOUT GENERATOR Below is the diagram for regulator connection
41. sion Av Prefeito Waldemar Grubba 3000 89256 900 Jaragu do Sul SC Brazil Phone 55 47 3276 4002 Fax 55 47 3276 4060 www weg net 52 Regulador Autom tico de Tens o GRT7 TH4 www weg net NOTAS Regulador Autom tico de Tens o GRT7 TH4 53 WEG Equipamentos El tricos S A Internation Division AV Prefeito Waldemar Grubba 3000 89256 900 Jaragu do Sul SC Brasil Phone 55 47 3276 4002 Fax 55 47 3276 4060 www weg net
42. sistive loads must be applied and the system checked for good response as below Resistive Loads It will not present compensation with resistive load keeping the excitation current and generator voltage constant in the value adjusted via trimpot Vad In case of compensation it indicates that TC is in the wrong phase Inductive Loads With inductive load application it shall present negative compensation decreasing the excitation current corresponding to the gain adjusted in the trimpot droop 0 to 15 voltage adjusted in the Vad If the compensation is positive it indicates the TC is inverted Capacitive Loads With application of capacitive loads it will present a positive compensation increasing the excitation current corresponding to the gain adjusted in the trimpot droop 0 to 15 voltage adjusted in the Vad If the compensation is positive it indicates the TC is inverted Accuracy class of 0 6C12 5 Window or bar type Transformer ratio will be In 5A or In 1A where In xA is the ratio of the TC primary Ex 100 5A 150 5A 100 14 secondary current for regulator PAR 5 and 1A for regulator PAR 1 The current in TC primary must be 20 bigger than the nominal current of the machine TC operation frequency must be equal to the generator frequency TC isolation voltage class must be bigger than the generator output voltage It must support 1 2 x In Automatic Voltage Regulator GRT7 TH4 15 ug www weg
43. tensi n de salida del generador 9 2 CONEXI N DEL CIRCUITO DE POTENCIA La tensi n del generador o del bobinado auxiliar se conecta a los bornes 3 y E3 4 Esta Tensi n rectificada es aplicada controladamente en el campo de la excitatriz del generador 9 3 ENCENDIDO DEL CAMPO La generaci n empieza a trav s de la tensi n residual del generador Despu s que la tensi n atingir aproximadamente 1096 de la nominal el regulador controla la tensi n del generador haciendo con que la tensi n ascienda a trav s de la rampa inicial en aproximadamente 3 segundos hasta atingir la tensi n nominal A partir de este momento el circuito de controle del PID mantendr la tensi n de salida del generador constante de acuerdo con el valor ajustado 9 4 OPERACI N U F Este modo de operaci n es determinado por el trimpot P5 jump J1 e componentes asociados El jump J1 determina la frecuencia de operaci n que sigue la l gica siguiente J1 cerrado 60Hz J1 abierto 50Hz El trimpot P5 determina el punto de actuaci n del modo U F que puede ser de la frecuencia nominal Fn hasta 1 3 de Fn El valor sale ajustado de la f brica con 1096 abajo de la Fn Para operaci n en 60Hz se hace el ajuste para 54Hz y para operaci n en 50Hz se hace el ajuste para 45Hz ver fig 1 Este valor puede ser alterado de acuerdo con la necesidad de cada aplicaci n z1 5 2 o S U o U o o o D E 3 lt S Frecuencia Hz Frecuencia
44. the residual voltage of the generator Once the voltage has reached about 10 of the nominal voltage the regulator controls the generator voltage causing it to rise through the initial ramp in approximately 3 seconds When the generator reaches its nominal value the PID control loop will maintain the generator output voltage constant within the adjusted value 9 4 U F OPERATION This operation is determined by trimpot P5 jumper J1 and associated components The J1 jumper determines the operating frequency 50 or 60 Hz following the logic below Ji closed 60 Hz Ji open 50Hz Trimpot P5 determines the set point of the U F mode that can be from the nominal frequency Fn down to 1 8 of Fn the value of which comes out of the factory adjusted to 1096 below Fn For operation at 60Hz it is adjusted to 54Hz and for operation at 50 Hz it is adjusted to 45Hz see Fig 1 the value of which can be changed based on each application requirements U 3 U 5 lt 5i 5i lt lt Frequency Hz Frequency Hz 45 50 BA do een 14 Automatic Voltage Regulator GRT7 TH4 www weg net ug 9 5 PARALLEL OPERATION FOR TWO OR MORE GENERATORS The reactive compensation method applied is called a phasor diagram see fig 02 Through this diagram the generator output voltage signal is measured and compared with the generator current voltage The result of this interaction introduces a sensing error of the actual voltage signal
45. xcessively low P P Increase droop adjustment rotating trimpot P2 clockwise CW _ Correct speed regulation Generated voltage decreases when load Dropping Speedol ME Caving MAGANG is applied and it doesn t return Adjust Under frequency protection by rotating Under frequency protection engaged trimpot P5 clockwise CW With the regulator switched on use external reel Oda NONE N battery 12Vcc to force excitation Generator voltage does not increase Terminals F and F are inverted Invert F and F Dynamic not well adjusted Adjust trimpots P3 and P4 Generated voltage oscillates at no load 9 Generator excitation voltage excessively low Insert 10 1 100W resistor in series with field Lara emos Eliminate auxiliary coil and proceed with the Voltage oscillates at a specific load point high y connections according to the diagrams of page 13 Lack of sensing Check if generator phases are present in the V Faulty electronic circuit sensing Voltage surges Sensing voltage incompatible with If the regulator is encapsulated replace it regulator For battery diesel generator where the generator neutral is grounded battery should always be used independently 15 PREVENTIVE MAINTENANCE Periodical inspections of the equipment are required to ensure they are clean dust and moisture free It is essential that all