Home

TAD-30K (GB/ES)

image

Contents

1. 3 8 TROUBLESHOOTING SYMPTOM CAUSE SOLUTION 9 SPECIFICATIONS MODEL ENGLISH TAD 30K Unit does not work Power cut The plug has been plugged improperly The full tank indicator is ON Tank is full Wait for power to be supplied again Plug in again Remove the drain water from the drain tank Unit sud denly stops during in operation The indoor tempera ture has reached the set temperature level The preset time is up The full tank indicator is ON Tank is full Reset the tempera ture level Reset the timer Remove the drain water from the drain tank COOLING CAPACITY 3 0 kW 10 000 BTU H DEHUMIDIFYING CAPACITY 0 42 gal h 1 6 L H POWER SOURCE Single Phase 220V 50Hz POWER CONSUMPTION 1200 W OPERATING CURRENT 9 5 A AIR FLOW MAX 177 CFM 300 m7 h OPERATING TEMP RANGE 18 C 35 C 64 F 95F DIMENSIONS WxHxD 17 1 8 x 30 1 4 x 17 435 x 770 x 430 mm Unit runs in termittently Malfunction Surrounding temper ature is too high or too low Exhaust duct hose is blocked Contact your dealer Check the duct hose Unit func tions but the room is not cooled Window or door is left open in the room There is heat source in the room or too many of people in it Air intake grille is clogged Filter is too dirty Temper
2. TAD 30K GB ES 10 10 20 11 39 AM 4 OPTIONAL ACCESSORIES When you need a longer size window panel please purchase the extension window panel B and use it with the original window panel A EXTENSION WINDOW PANEL B M 80 cm 31 1 2 EXTENSION WINDOW PANEL B L 142 cm 56 ENGLISH LIMITED WARRANTY TOYOTOMI CO LTD TOYOTOMI warrants each product and any parts thereof sold by it to be free from defects in materials or workmanship under normal use and service for TWELVE 12 MONTHS from the date of delivery to the origi nal purchaser at retail subject to the following terms and conditions WHAT IS COVERED Product or any parts thereof which are defective in materials or workmanship WHAT IS NOT COVERED This warranty does not extend to any defect due to the neg ligence of others failure to install operate or maintain unit in accordance with instructions operating and maintenance instructions are furnished with each new unit unreasonable use accidents alteration use of unauthorized or non stan dardized TOYOTOMI parts and accessories electrical mal function i e as resulting from large power surges short cir cuit etc incorrect installation or repair by anyone other than a service facility specified by TOYOTOMI WHO IS COVERED The original purchaser at retail WHAT WE WILL DO TOYOTOMI will either
3. have other rights which vary from state to state TAD 30K GB ES 10 10 20 11 39 AM 5 RESUMEN La unidad ha sido disenada para proporcionar un acondi cionamiento de aire localizado La unidad aumentar su confortabilidad ya sea que est en su lugar de trabajo o sentado c modamente en su sill n preferido Cuatro 4 ruedas permiten desplazar f cilmente la unidad de una habitaci n a otra Refrigera y seca el aire simult neamente para crear un ambiente confortable aun en los d as h medos y lluviosos Utilizado como deshumidifador esta unidad le ayu dar a mantener sus muebles y tapices en buenas condiciones Los acondicionadores de aire convencionales consumen gran cantidad de energ a para enfriar una habitaci n completa in cluyendo las paredes y los muebles En cambio la unidad crea una zona de aire fr o y seco s lo donde es necesario No der rocha energ a enfriando los espacios circundantes Su operaci n es muy f cil El timer incorporado permite ajustar la unidad para que se active o desactive autom ticamente al cabo de un per odo de tiempo programable entre 1 a 12 horas Esto es especialmente conveniente antes de irse a la cama No requiere ventilaci n Sin embargo si va a usar la unidad exclusivamente en un solo lugar podr aumentar la eficiencia de enfriamiento utilizando el kit para ventana ofrecido como accesorio CARACTERISTICAS FUNCIONALES 1 OPERACION DE ENFRIAMIENTO Normalmente e
4. instrucciones de operaci n y man tenimiento se entregan con cada unidad nueva uso inde bido accidentes alteraci n empleo de piezas y accesorios no autorizados o no estandarizados de TOYOTOMI fallo el ctrico que resultaren por ejemplo de una sobreintensidad transitoria fuerte cortocircuito etc instalaci n incorrecta reparaci n por personal ajeno al establecimiento de servicio especificado por TOYOTOMI Titularidad El comprador original al detalle Alcance TOYOTOMI a opci n propia reparar o sustituir gra tuitamente todas las piezas defectuosas cubiertas por esta garant a limitada sobre una base de devoluci n a su provee dor o distribuidor autorizado TOYOTOMI m s cercano C mo debe reclamar el servicio de garant a Deber devolver el producto o componente defectuoso a cualquier proveedor o distribuidor autorizado de TOYOTOMI junto con esta GARAN TIA LIMITADA y una copia de su boleta de compra Si no dispone de servicio en su localidad comun quese con nuestro DEPARTAMENTO DE ATENCION AL CLIENTE en BBR S A Av Vitacura 5748 Santiago Fono 600 586 5000 www toyotomi cl LO ANTERIOR EXPRESA TODAS LAS OBLIGACIONES Y RE SPONSABILIDADES DE TOYOTOMI CON RESPECTO A LA CALI DAD DEL PRODUCTO SUMINISTRADO POR EL MISMO TODAS LAS DEMAS GARANTIAS EXPRESAS O IMPLICITAS IN CLUYENDO GARANTIAS IMPLICITAS DE COMERCIALIDAD E IDONEIDAD PARA UN PROPOSITO EN PARTICULAR QUEDAN RECHAZADAS TOYOTOMI NO SERA RESPON
5. los tubos e NO haga funcionar con el filtro desmontado A PRECAUCION e Mantenga la unidad alejada m s de 50 cm 20 in de la pared o de otros objetos Fig D e Si la unidad est funcionando en la modalidad de ENFRI AMIENTO en un lugar de mucha humedad las placas su perior y posterior podr an cubrirse de gotitas de agua Seque completamente antes de que lleguen a mojar el piso o la alfombra TAD 30K GB ES 10 10 20 11 39 AM 6 e Saque el agua de drenaje antes de mover la unidad e Para reducir la corrosi n al m nimo NO la utilice en ambi entes de aire salino e la haga funcionar a la luz directa del sol e NO la utilice para fines particulares tales como la conser vaci n de alimentos animales plantas dispositivos de precisi n artes y medicina e NO ponga nunca un animal plantas o equipo de combusti n en un sitio sujeto al flujo directo de aire de la unidad e NO apoye ni coloque un objeto encima de la unidad e NO ponga la unidad de costado o boca abajo 3 OPERACION PASOS DE OPERACION 1 Oprima el bot n POWER conexi n C1 para ponerlo en ON La luz de modalidad de enfriamiento COOL C7 y la luz de Low se encienden en este momento y funciona la unidad 2 OPRIMA EL BOTON MODE C2 Oprima el bot n de modalidad C2 para ajustar su modali dad de funcionamiento deseado COOL enfriamiento C7 DEHUMIDIFY seco C8 o FAN ventilador C9 Moda
6. 4 cm 37 pulg M n 72 cm 28 1 4 pulg EMPLEO DEL JUEGO DEL CONDUCTO DE EVACUACI N Fig 1 Inserte el extremo de la manguera del conducto del escape tubo flexible 12 en la boquilla adaptadora de la manguera del conducto de escape 11 gir ndola en sentido contrario a las agujas del reloj en el tubo y fijando una de las boquillas adaptadoras de la manguera del conducto de escape 11 en la salida de escape B2 gir ndola hasta que se bloquee 2 Extienda la manguera del conducto de escape 12 y cierre la ventana o la puerta todo lo que pueda pillando la boquilla adaptadora de la manguera del conducto de escape 11 NOTA Instale la unidad lo m s cerca que sea posible de la ventana o puerta UTILIZACI N DEL KIT DEL PANEL DE LA VENTANA Fig J NOTA Es posible la instalaci n en ventanas utilizando el juego de conducto de evacuaci n y el kit del panel de la ventana 1 Fije la rejilla de la manguera del conducto de evacuati n J3 en el panel de la ventana con cuatro 4 tornillos Aseg rese que el panel est extendido para que los tornil los no penetren en la parte de corredera del panel 2 Abra la ventana Coloque el panel de la ventana en la ventana extendi ndo lo para que coincida con el ancho de la ventana Una vez extendido el panel el panel puede bloquearse con su an cho apretando los dos 2 tornillos en el panel superior 4 Cierre la ventana 5 Instale la tobera del adaptador de la mangue
7. AFETY TIPS IMPORTANT e Read instructions carefully before operation e The unit should be operated when the room temperature is between 18 C 64 F to 35 C 95 F If the room temperature is below 18 C 64 F ice may form on the coils If the room temperature is above 35 C 95 F the compressor will auto matically shut off to protect itself e ALWAYS wait 3 min to restart after turning unit off A WARNING e NEVER expose infants handicapped persons or senior persons directly to the airflow Adjust the airflow direction e Keep children away from unit Children are particularly li able to this danger The inside fan is running at high speed Covering them may deteriorate air conditioner per formance or cause it to become inoperative e NEVER insert objects of any kind into the air intake or air outlet e DO NOT unplug if your hands are wet An electrical shock may occur e DO NOT operate in a wet location e ALWAYS plug into 220 V 50 Hz single phase electrical out let e Be sure the power plug fits the receptacle securely e DO NOT run power cord under carpets rugs or floor mats of any kind e DO NOT attempt to shorten or alter power cord in any way e DO NOT apply any excessive force or pressure to the pow er supply cord e Make sure that the plug is free of dust e DO NOT use an extension cord e DO NOT turn on and off by inserting or removing the pow er plug which may cause electric shock or fire e
8. AUTION e DO NOT rinse the charcoal filter with water CLEANING SURFACE Clean the outside of the unit with a soft damp cloth A CAUTION e NEVER use gasoline solvents chemical products or polish as they could damage the surfaces 6 LONG TERM STORAGE At the end of each season or when you do not plan to use your unit for an extended period of time the following procedures are recommended 1 Run the unit 5 or 6 hours with only the FAN C9 mode operating in order to dry the inside 2 Remove the drain water from the tank and unplug the unit Clean the unit Wipe off any dirt or dust on the unit with a soft damp cloth or a vacuum cleaner and then wipe again using a soft dry cloth 4 Clean the air intake grille B7 and replace it 5 Store the unit The original shipping carton is the best place to store your unit If you do not have the original packing materials cover the unit with a large plastic bag and store in a cool dry place A CAUTION e ALWAYS store the unit in the vertical position e DO NOT put heavy objects on top of the unit 7 TRANSPORTATION Preferably keep the unit in the vertical position during trans portation If this is not possible then lay it on its rear side when at destination put the unit back in the vertical position and wait at least ten 10 minutes before using it Before transporting moving the unit make sure the drain tank is empty TAD 30K GB ES 10 10 20 11 39 AM
9. FLECTOR DE AIRE Las rejillas verticales A2 pueden ajustarse hacia la derecha e izquierda manualmente en el sentido deseado Fig E 6 OPERACION DE PARADA Oprima el bot n POWER C1 para que se apaguen todas las luces FUNCIONAMIENTO DEL TIMER Desactivaci n autom tica Con la unidad en la modalidad de enfriamiento oprima el bot n Timer C4 para seleccionar el n mero de horas que desea que la unidad funcione en la modalidad de enfri amiento hasta su desactivado autom tico Activaci n autom tica Con la unidad desactivada oprima el bot n Timer C4 para seleccionar el n mero de horas que desea esperar hasta que la unidad empiece a funcionar autom ticamente USO DEL CONTROL REMOTO Las funciones act an de la misma forma que el panel de con troles del acondicionador de aire Fig C ESPANOL Pilas Desmonte la cubierta en la parte trasera del control re moto y coloque las pilas con las polaridades y apun tando en el sentido correcto Fig H A PRECAUCION e Utilice s lo pilas AAA o IEC R03 de 1 5V NO trate de recargar las pilas entregadas Todas las pilas deben cambiarse al mismo tiempo NO se deshaga de las pilas al fuego ya que pueden explotar NO instale las pilas con la polaridad invertida Mantenga las pilas y otros objetos que puedan tragarse fuera del alcance de ni os de corta edad Llame inmediata mente a un m dico si tragara un objeto 4 DRENAJE DE AGUA EXCESIVA F
10. ONTROL The compressor will automatically shift to ON or OFF to maintain the desired temperature 4 TIMER OPERATION The unit will turn on and off after the designated period of time 1 2 3 12 hours 5 AUTOMATIC SHUT OFF MECHANISM WHEN THE DRAIN TANK IS FULL When the drain tank is full the unit will be automatically shut off The warning lamp will light It is always required to press the power button twice to resume operation after the condensed water is removed from the tank 6 AIR FILTER A pre filter protects the unit from dust 1 DESCRIPTION Fig A FRONT A1 Air outlet A2 Vertical louver A3 Front panel A4 Operation panel A5 Carrying handle A6 Horizontal louver A7 Caster Fig B REAR B1 Air intake Evaporator B2 Exhaust outlet B3 Air intake Condenser B4 Power supply cord B5 Power plug B6 Drain water outlet B7 Air intake grille Pre filter Fig C OPERATION PANEL C1 Power button C2 Mode button C3 Fan speed button C4 Timer button C5 Adjust buttons C6 Warning lamp Tank full C7 Cool mode lamp green C8 Dry mode lamp orange C9 Fan mode lamp yellow C10 Room temp lamp C11 Set temp lamp ENGLISH C12 Timer set lamp C13 Digital indicator C14 C F toggle button Remote control Fig EXHAUST DUCT SET 11 Exhaust duct hose adapter nozzle 2 pcs I2 Exhaust duct hose Fig J WINDOW PANEL KIT J1 Window panel J2 Window panel extension J3 Exhaust duct hose grille J4 Cover J5 Screws 2 S
11. SABLE DE NINGUNA MANERA POR LOS LAS PERDIDAS QUE RE SULTAREN DEL USO DE ESTE PRODUCTO NI DE CUA LESQUIERA GASTOS O INCONVENIENTES INCURRIDOS PERDIDA DE LUCRO O POR LOS DANOS DIRECTOS O CONSE CUENTES QUE PUDIERAN SURGIR DEL USO O ERROR DE USO DE INCAPACIDAD EN EL USO O POR LOS DANOS RE SULTANTES DE O ATRIBUIBLES A DEFECTOS DEL PRODUCTO S lo TOYOTOMI cuenta con la autorizaci n para extender o modificar los t rminos de esta garant a limitada En algunos estados no se permiten limitaciones o exclu siones en cuanto a la duraci n de las garant as impl citas o no permiten la exclusi n o la limitaci n de da os inciden tales o consecuentes de manera que es posible que la ante dicha limitaci n o exclusi n no se aplique a usted Esta garant a limitada le confiere a usted derechos legales es pec ficos y tal vez le correspondan otros derechos que pueden variar de un estado a otro TAD 30K GB ES 10 10 20 11 39 AM a New 11 10 TOYOTOMI CO LTD 5 17 Momozono cho Mizuho ku Nagoya 467 0855 Japan www toyotomi jp Printed in China 6
12. TACION Monofasico 220V 50Hz CONSUMO ELECTRICO 1200 W CORRIENTE DE FUNCIONAMIENTO 9 5 A 177 CFM 300 m h 18 C 35 C 64 95 0 42 gal h 1 6 L H FLUJO DE AIRE MAX GAMA DE TEMP DE FUNCIONAMIENTO 17 1 8 x 30 1 4 x 17 DIMENSIONES AnxAlxProf 435 x 770 x 430 mm PESO 66 Lbs 30 kg La unidad se detiene repentina mente du rante el fun cionamiento La temperatura interi or ha llegado al nivel de temperatura ajus tado Se acab el tiempo prefijado El indicador de tanque lleno est en cendido El tanque est lleno Reajuste el nivel de temperatura Reajuste el timer Elimine el agua de drenaje del tanque de drenaje La unidad funciona in termitente mente Mal funcionamiento Temperatura ambi ente demasiado alta O baja La manguera del con ducto de evacuaci n est tapado Contacte al Servicio t cnico Verifique la manguera del con ducto La unidad funciona pero no se enfr a la habitaci n La ventana o puerta se dej abierta en la habitaci n Hay una fuente de calor en la habitaci n o demasiadas per sonas en ella La rejilla de entrada de aire est tapada El filtro est muy su cio El ajuste de temper atura est demasiado alto Cierre todas las ven tanas y puertas Saque la fuente de calor de la habitaci n Limpie la rejilla de entrada de aire Cambie el
13. TAD 30K GB ES 10 10 20 11 39 AM b TOYOTOMI PORTABLE AIR CONDITIONER ACONDICIONADOR DE AIRE PORTATIL TAD 30K INSTRUCTION MANUAL ENGLISH P 1 MANUAL DE INSTRUCCIONES ESPANOL P 5 CO E E db PI wong TAD 30K GB ES 10 10 20 11 39 AM c 0 in more than 2 50cm more than 50cm 20 in TAD 30K GB ES 10 10 20 11 39 AM d PARTS LIST j NO PART NAME Base pan assembly NO PART NAME Capacitor A Rear FM NO PART NAME Carton Caster Main circuit board Exhaust duct hose Float CapacitorB Compressor Exhaust duct hose adapter nozzle Micro switch Indication lamp circuit Exhaust duct hose grille Drain motor Front panel Cover Blade Power supply cord Window panel kit Compressor Drain cap Instruction manual 0 NO JOB INA Rear fan motor Rear panel Styrofoam Bottom Rear fan Intake air grille Styrofoam Right Capacitor C Front FM Right side panel Styrofoam Left Front fan motor Left side panel Cardboard Front fan Remote control TAD 30K GB ES 10 10 20 11 39 AM 1 SUMMARY The idea behi
14. ature setting is too high Close all windows and door Move out any heat source in the room Clean the air intake grille Replace the filter Lower the tempera ture setting Condensed water is spilled out when mov ing the unit The tank is nearly full BEFORE CALLING FOR SERVICE The followings are not defects A hissing noise or hollow sound pipes Remove the drain plug on the rear bot tom of the unit drain off the water then the unit will be in opera tion automatically This sound is generated from the refrigerant flowing within A squeaking noise This noise is generated from the gt unit when it is expands or con tracts with temperature changes Odor Such odor as tobacco cosmetics gt or foods may accumulate in the unit The unit does not start nor immediately To prevent overloading the com change operation mode gt pressor motor the unit will be stopped for more than 3 minutes WEIGHT 66 Lbs 30 kg COMPRESSOR ROTARY REFRIGERANT R 410A NOTE Cooling air capacity will vary according to temperature and humidity of the room 10 VENTING KIT ACCESSORIES If the unit is to be used exclusively in one space the cooling ef ficiency will be enhanced by using the following venting kit ac cessories EXHAUST DUCT SET FLEXIBLE TUBE Fig Max 1 2m 4 ft WINDOW PANEL KIT Fig J For s
15. dified as it passes through the unit without being in full cool mode In DEHUMIDIFY mode operation you cannot change the fan speed FAN mode C9 The FAN mode provides only circulation of room air so that you cannot set the room temperature 3 PRESS TIMER TEMPERATURE ADJUST BUTTONS C5 Set the desired room temperature by pressing UP button A or DOWN button W The default display is room tem perature When A or W button is pressed the set temperature is displayed and may be adjusted After 15 seconds the dis play will revert back to room temperature By pressing both buttons at once the display will toggle between Celsius and Fahrenheit When using the remote control press the C F toggle button C15 4 PRESS FAN SPEED BUTTON C3 Press the fan speed button C3 to set the desired air flow rate High Operation at a high air flow Med lt Operation at a medium air flow LOW Operation at a low air flow 5 AIR DEFLECTION The vertical louvers A2 may be set on right and left man ually in desired direction Fig E 6 STOP OPERATION Press the Power button C1 and all lights will go out TIMER OPERATION Auto turning OFF With unit in cool mode press Timer button C4 to select number of hours you would like the unit to run in cool mode until it automatically shuts off Auto turning ON With unit powered off press Timer button C4 to select number of hours until you wou
16. enaje B7 Rejilla de toma de aire Filtro previo Fig C PANEL DE MANDOS C1 Bot n de conexi n C2 Bot n de modalidad C3 Bot n de velocidad del ventilador ESPANOL C4 Boton de timer C5 Botones de ajuste C6 Luz de advertencia Tanque lleno C7 Luz de modalidad de enfriamiento verde C8 Luz de modalidad de desumidificaci n naranja C9 Luz de modalidad de ventilaci n amarillo C10 Luz de temperatura habitaci n C11 Luz de temperatura ajustada C12 Luz de ajuste del timer C13 Indicador digital C14 Bot n de conmutaci n Celcius Farenheit Control remoto Fig l JUEGO DEL CONDUCTO DE EVACUACION I1 Tobera del adaptador de la manguera del conducto de evacuaci n 2 pzas 12 Manguera del conducto de evacuaci n tubo flexible Fig J KIT DEL PANEL DE VENTANA DE PLASTICO J1 Panel de ventana J2 Extensi n del panel de ventana J3 Rejilla de la manguera del conducto de evacuaci n J4 Cubierta J5 Tornillos 2 INFORMACION SOBRE SEGURIDAD IMPORTANTE e Lea atentamente las instrucciones antes de usar la unidad e Haga funcionar la unidad a una temperatura ambiente comprendida entre 18 C 64 F y 35 C 95 F Si la temper atura ambiente es inferior a 18 C 64 F se podr formar hielo sobre los serpentines Si la temperatura ambiente est por encima de 35 C 95 F el compresor se desacti var autom ticamente para fines de autoprotecci n e Espere SIEMPRE 3 minutos antes de volver a encender la un
17. filtro Baje el ajuste de tem peratura El agua con densada se derrama cuando mueva la unidad El tanque est casi lleno ANTES DE LLAMAR EL SERVICIO Las siguientes condiciones no son anomal as Abra el tap n de drenaje en la parte inferior de la unidad drene el agua y la unidad funcionar autom ticamente Silbido o ruido sordo gt Producido por el refrigerante circulando dentro de los tubos Producido por el acondicionador de aire debido a la expansi n o Chirrido contracci n producida por los cambios de temperatura El olor de los cigarrillos Olores cosm ticos o alimentos podr a acumularse en la unidad interior Para evitar que se sobrecargue el motor del compresor la unidad dejar de funcionar durante m s de 3 minutos La unidad no arranca ni cambia inmediatamente de modalidad de op eraci n COMPRESOR REFRIGERANTE Rotatorio R 410A NOTA La capacidad del aire de enfriamiento variar seg n la temperatura y la humedad de la habitaci n 10 ACCESORIOS DEL KIT DE VENTILACION Si se va a usar la unidad para uso exclusivo en un solo lugar se conseguir mejorar la eficiencia de la refrigeraci n usando los siguientes accesorios del kit de ventilaci n JUEGO DE CONDUCTO DE EVACUACI N TUBO FLEXIBLE Fig M x 1 2 m 4 pies KIT DEL PANEL DE LA VENTANA Fig J Para ventanas correderas y de guillotina M x 9
18. idad A ADVERTENCIA e No permita NUNCA gue los beb s las personas con im pedimentos o las personas ancianas queden directamente expuestos a la corriente de aire Ajuste la direcci n del flu jo de aire e Mantenga a los ni os alejados de la unidad Especialmente tenga cuidado con los ni os debido al peligro que repre senta el ventilador interior funcionando a alta velocidad Asimismo nunca cubra la unidad ya que se degradar el rendimiento del acondicionador de aire o se volver inop erante e No introduzca NUNCA objetos de ninguna clase dentro de la toma o de la salida de aire e NO desenchufe con las manos mojadas Podr a sufrir un electrochoque e NO lo haga funcionar en un sitio mojado e Enchufe SIEMPRE en una toma de 220 voltios 50 Hz corri ente monof sica e Aseg rese de que el enchufe quede firmemente conectado a la toma e NO haga pasar el cable de alimentaci n debajo de las al fombras esteras o tapetes de ninguna clase e NO intente nunca acortar ni alterar el cable de ali mentaci n e NO aplique presi n ni fuerza excesiva al cable de ali mentaci n e Aseg rese de que el enchufe est libre de polvo e use un cable de extensi n e NO intente nunca encender o apagar la unidad enchufando o desenchufando el cable de alimentaci n e Si existe el peligro de que caiga un rayo apague el acondi cionador de aire y desench felo del tomacorriente e toque el evaporador el condensador y
19. ig F Drene el exceso de agua del tanque colocando una bande ja debajo de la salida de agua de drenaje Fig F2 2 Abra el tap n de drenaje y deje que el agua se drene en la bandeja 3 Cuando el agua deja de salir vuelva a colocar el tapon de drenaje Retire la bandeja de agua 5 Haga funcionar la unidad en la modalidad de ventilador para secar el interior de la unidad P NOTA Elimine el agua de drenaje del tanque una vez a la semana 5 LIMPIEZA LIMPIEZA DE LA REJILLA DE ENTRADA DE AIRE Fig G 1 Limpie la rejilla de entrada de aire B7 una vez cada dos semanas 2 Para desmontar la rejilla de entrada de aire B7 tire de al rejilla 3 Elimine el polvo con una aspiradora ADVERTENCIA e NO toque el evaporador Podr a causar lesiones o da os PRECAUCION e lave el filtro de carb n con agua LIMPIEZA DE LA SUPERFICIE Limpie el exterior de la unidad con un pa o suave y h medo A PRECAUCION e No use NUNCA gasolina solventes productos qu micos o pulimentador pues se podr n da ar las superficies 6 A DE LARGA DURA Al final de la estaci n o cuando no tenga planeado utilizar la unidad durante mucho tiempo se recomiendan los sigu ientes procedimientos 1 Haga funcionar la unidad 5 6 horas nicamente en la modal idad FAN ventilador C9 para que se seque el interior 2 Vac e el tanque de drenaje y desenchufe la unidad 3 Limpie la unidad Limpie las mancha
20. l aire fr o sale por las rejillas delanteras im pulsado por el ventilador de circulaci n que tiene tres 3 etapas de velocidad 2 OPERACION AUTOMATICA Despu s de ajustar a la funci n deseada permanecer en la memoria mientras la unidad se encuentre enchufada al tomacorriente mural Si ocurre una interrupci n del sumin istro de energ a deber volver a introducir la funci n de seada despu s que se restablezca la energ a 3 TERMOCONTROL El compresor conmutar autom ticamente a ON conexi n u OFF desconexi n para mantener la temper atura deseada 4 OPERACION DEL TIMER El timer permite programar la unidad para que se active y desactive despu s de un cierto per odo de tiempo 1 2 3 12 horas 5 MECANISMO DE DESACTIVADO AUTOM TICO DEBIDO A TANQUE DE DRENAJE LLENO Cuando se llene el tanque de drenaje la unidad se desacti var autom ticamente La l mpara de advertencia se en cender Oprima dos veces el bot n POWER conexi n para reanudar la operaci n despu s de vaciar el agua con densada del tanque 6 FILTROS DE AIRE Un filtro previo protege la unidad del polvo 1 DESCRIPCION Fig A FRENTE A1 Salida de aire A2 Rejilla vertical A3 Panel frontal A4 Panel de operaci n A5 Manillas para transporte A6 Rejilla horizontal A7 Ruedas Fig B ATRAS B1 Toma de aire Evaporador B2 Salida de aire B3 Toma de aire Condensador B4 Cable de alimentaci n B5 Enchufe B6 Salida de agua de dr
21. ld like the unit to automati cally start USING REMOTE CONTROL The functions work the same as your air conditioner s op eration panel Fig C Batteries Remove the cover on the back of the remote con trol and insert the batteries with the and poles point ing in the proper direction Fig H A CAUTION e Use only AAA or IEC R03 1 5V batteries e DO NOT attempt to recharge the supplied batteries e All batteries should be replaced at the same time e DO NOT dispose of the batteries in a fire as they may ex plode DO NOT install the batteries with the polarity re versed e Keep batteries and other things that could be swallowed away from young children Contact a doctor immediately if an object is swallowed 4 DRAINING EXCESS WATER Fig F 1 Drain excess water from the tank by placing a pan under the drain water outlet Fig F2 2 Remove the drain plug and let the water drain into the pan ENGLISH 3 When the water stops draining out replace the drain plug 4 Remove the pan of water 5 Operate the unit in Fan mode to dry the interior of the unit NOTE Remove the drain water from the tank once a week 5 CLEANING CLEANING AIR INTAKE GRILLE Fig G 1 Clean the air intake grille B7 once every two weeks 2 To remove the air intake grille B7 pull the grille off 3 Remove the dust with a vacuum cleaner A WARNING e DO NOT touch the evaporator It may cause injury or dam age A C
22. lf there is a fear of lightning stop the unit and disconnect the power supply cord e DO NOT touch the evaporator condenser and pipes e DO NOT operate with filter removed A CAUTION e Keep unit more than 50 cm 20 in away from any objects or wall Fig D e If the unit is operated in COOL mode in an area of very high moisture the top plate and the rear plate may get covered with a mist Wipe off any mist before it has a chance to get on the floor or rug e Remove drain water before moving unit e To minimize corrosion DO NOT use in damp salty air area e DO NOT operate in direct sunlight e DO NOT use for such particular purpose as preservation of foodstuff animals plants precision appliances arts and medicine e DO NOT place an animal plants or combustion equipment in a place which is subjected to the direct air flow of the unit e DO NOT ride or place the objects on the unit e DO NOT turn the unit on its side or upside down TAD 30K GB ES 10 10 20 11 39 AM 2 3 OPERATION OPERATING STEPS 1 PRESS POWER BUTTON C1 TO ON Cool mode lamp C7 and Low lamp are lit at this time and unit starts 2 PRESS MODE BUTTON C2 Press the mode button C2 to set your desired operation mode COOL C7 DEHUMIDIFY C8 or FAN C9 COOL mode C7 During the COOL mode the air is cooled and hot air is ex hausted to the outside air through the exhaust duct hose DRY mode C8 Air is dehumi
23. lidad COOL enfriamiento C7 Durante la modalidad COOL el aire se enfr a y sale el aire caliente al exterior por la manguera del conducto de evac uaci n Modalidad DEHUMIDIFY seco C8 aire se deshumidifica al pasar por la unidad sin estar en la modalidad de enfriamiento total En el funcionamiento de la modalidad DEHUMIDIFY no puede cambiar la ve locidad del ventilador Modalidad FAN ventilador C9 La modalidad FAN solo produce circulacion del aire inte rior y no puede ajustar la temperatura de la habitaci n 3 OPRIMA LOS BOTONES DE TIMER AJUSTE DE TEM PERATURA C5 Ajuste a la temperatura ambiente deseada presionando el bot n UP A o el bot n DOWN W La indicaci n por omisi n es la temperatura de la habitaci n Cuando se oprime el bot n A o W aparece la temper atura ajustada y puede ajustarlo Despu s de 15 segundos la indicaci n volver a la temperatura de la habitaci n Oprimiendo ambos botones a la vez la indicaci n se con mutar entre Celsio y Fahrenheit Cuando utilice el control remoto oprima el bot n de conmutaci n C F C15 4 OPRIMA EL BOTON SELECTOR DE VELOCIDAD DEL VENTILADOR C3 Oprima el bot n selector C3 de velocidad del ventilador para ajustar al r gimen de flujo de aire deseado HI alto sasana eaaa Funciona a un flujo de aire alto MED medio Funciona a un flujo de aire medio CODA O ist Funciona a un flujo de aire bajo 5 DE
24. liding and double hung windows Max 94cm 37 in Min 72cm 28 1 4 in USING EXHAUST DUCT SET Fig 1 Insert both ends of exhaust duct hose flexible tube 12 in to exhaust duct hose adapter nozzle 11 by turning it counter clockwise onto the tube and fix one of the exhaust dust hose adapter nozzle 11 into exhaust outlet B2 by turning it clockwise until it locks Extend the exhaust duct hose 12 and close the window or door as far as possible trapping the exhaust duct hose adapter nozzle 11 NOTE Place the unit as close as possible to the window or door USING WINDOW PANEL KIT Fig J NOTE Window installations are possible by the use of the exhaust duct set and window planel kit Fix the exhaust duct hose grill J3 to the window panel with four 4 screws Make sure that the panel is extended so that screws do not go into sliding portion of panel 2 Open the window 3 Place the window panel in the window extending it to fit the width of the window Once panel is extended the pan el can be locked into this width by tightening the two 2 screws on the top panel 4 Close the window 5 Attach the exhaust duct hose adapter nozzle 11 on the ex haust duct hose grille J3 6 When not in use the exhaust duct hose adapter nozzle 11 may be closed off with the cover for exhaust duct hose grille J3 provided NOTE The same procedure can be adapted for vertical installation in sliding windows
25. nd the unit is to provide a localized supply of cool air The unit will greatly enhance your personal comfort whether at a work station or even in your favorite chair Four 4 casters enable you to move the unit easily from room to room It cools and dries the air at the same time so that you can stay comfortable even when it s humid or rainy outside Also your furnishings and fabrics are kept in good condition when it s used as dehumidifier Conventional air conditioners use large quantities of energy to cool an entire room including walls and furniture This unit creates a zone of cool and dry air only where it is needed It does not waste energy cooling the surroundings It s easy to operate The built in timer allows from 1 to 12 hours of operation which will automatically turn the unit on and off This is especially convenient at bedtime Venting is not required However if the unit is to be used exclu sively in one space the cooling efficiency will be enhanced by using the venting kit accessory which is included with the uit OPERATIONAL FEATURES 1 COOLING OPERATION Normally cool air is directed out the front louvers by the circulation fan which has three 3 stages of fan speed 2 AUTOMATIC OPERATION Once the desired function has been set it is memorized as long as it remains connected to the wall outlet In the event of a power failure the desired function must be re entered when power is restored 3 THERMO C
26. ra del conduc tor de evacuaci n 11 en la rejilla de la manguera del con ducto de evacuaci n J3 6 Cuando no lo utilice puede cerrar la tobera del adaptador de la manguera del conductor de evacuaci n 11 con la cu bierta entregada para la rejilla de la manguera del conduc to de evacuaci n J3 o TAD 30K GB ES 10 10 20 11 39 AM 8 ACCESORIOS OPCIONALES Cuando se necesita un panel de ventana de tama o m s largo compre el panel de ventana de extensi n B y util celo con el panel de ventana original A PANEL DE VENTANA DE EXTENSI N B M 80 cm 31 1 2 pulg PANEL DE VENTANA DE EXTENSION B L 142 cm 56 pulg ESPANOL GARANTIA LIMITADA TOYOTOMI CO LTD TOYOTOMI garantiza al comprador que este producto y sus correspondientes piezas estan li bres de defectos en material y mano de obra bajo empleo y servicio normales por un periodo de DOCE 12 MESES a partir de la fecha de la entrega al comprador original sujeto a los siguientes t rminos y condiciones Esta garantia cubre Al producto o cualquier Dieza del mis mo que presente defectos de material o de mano de obra Qu es lo que no esta cubierto Esta garantia no cubre ningun dano resultante de la negli gencia de terceros error de instalaci n operaci n o man tenimiento de la unidad de conformidad con las instruc ciones de instalaci n las
27. repair or re place at its option all defective parts free of charge that are covered by this limited warranty on a carry in basis to your nearest authorized dealer or distributor of TOYOTOMI WHAT YOU MUST DO FOR WARRANTY SERVICE You must return the defective Product or part to any authorized dealer or distributor of TOYOTOMI with this LIMITED WAR RANTY If service is not available locally please contact our CUSTOMER RELATIONS DEPARTMENT at BBR S A Av Vitacura 5748 Santiago Fono 600 586 5000 www toyotomi cl THE FOREGOING EXPRESSES ALL OF TOYOTOMI S OBLIG ATIONS AND LIABILITIES WITH RESPECT TO THE QUALITY OF PRODUCT FURNISHED BY IT ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED TOYOTOMI SHALL NOT BE LI ABLE FOR THE LOSS OF USE OF THE PRODUCT INCONVE NIENCE LOSS OR ANY OTHER DAMAGES DIRECT OR CONSEQUENTIAL ARISING OUT OF THE USE OF OR IN ABILITY TO USE THE PRODUCT OR DAMAGES RESULTING FROM OR ATTRIBUTABLE TO DEFECTS IN THE PRODUCT No other than TOYOTOMI has authority to extend or modify the terms of this Limited Warranty in any manner whatsoever Some states do not allow the exclusion or limitation of inci dental or consequential damages or limitations on how long an implied warranty lasts so these limitations or exclusions may not apply to you This Limited Warranty gives you spe cific legal rights and you may also
28. s y la suciedad de la unidad con un pa o suave h medo o con una aspiradora y luego p sele un pa o suave y seco 4 Limpie la rejilla de toma de aire B7 y reinst lelo 5 Almacene la unidad La caja de cart n original es el mejor sitio para guardar su unidad Si no ha conservado los materiales de embalaje originales cubra la unidad con una bolsa grande de pl stico y gu rdela en un lugar seco y fresco A PRECAUCION e SIEMPRE almacene la unidad en posici n vertical NO ponga objetos pesados encima de la unidad TAD 30K GB ES 10 10 20 11 39 AM 7 7 TRANSPORTE Durante el transporte se recomienda colocar la unidad en posi ci n vertical Si no es posible transportela acostada sobre el lado trasera y al llegar a destino regresela a la posici n verti cal Espere por lo menos diez 10 minutos antes de usarla Antes de transportar mover la unidad compruebe que el tanque de drenaje est vac o 8 LOCALIZACION DE AVERIAS S NTOMA CAUSA SOLUCION La unidad no funciona Falla de la ali mentaci n Enchufe mal conecta do El indicador de tanque lleno est en cendido El tanque est lleno Espere hasta que vuelva la electricidad Enchufe nuevamente Elimine el agua de drenaje del tanque de drenaje ESPANOL 9 ESPECIFICACIONES MODELO CAPACIDAD DE ENFRIAMIENTO TAD 30K 3 0 kW 10 000 BTU H CAPACIDAD DE DESHUMIDIFICACION FUENTE DE ALIMEN