Home

Manual Inflation Blood Pressure Monitor

image

Contents

1. AM or PM Press the MEMORY button to advance by increments of one hour Press the Date Time Setting button to set the current hour The minutes flash on the display 6 SETTING THE MINUTE Press the MEMORY button to advance by increments of one minute Press the Date Time Setting button to set the current minute The unit is ready for measurement TO CHANGE THE DATE TIME 1 Press the ON OFF button 2 Press the Date Time Setting button 3 When completed press the ON OFF button to turn unit off 11 APPLYING THE ARM CUFF 1 Connect the air tube of the arm cuff and the inflation bulb to their air jacks 2 Remove tight fitting clothing from your upper arm AS 3 Sit in a chair with your feet flat on the floor Place your arm on a table so the cuff is level with your heart 12 APPLYING THE ARM CUFF 4 Apply the cuff to your left upper arm so the blue arrow is centered on the inside of your arm and aligned with your middle finger The air tube runs down the inside of your arm The bottom of the cuff should be approximately 1 2 above your elbow 1 2 inch 1 2 cm Arrow Air Tube 5 Wrap the cuff firmly in place around your arm using the closure strip APPLYING THE CUFF ON THE RIGHT ARM Apply the cuff to your right upper arm so the blue arrow and the air tube runs along the inside of your arm The bottom of your cuff should be approximately 1 2 above your elbow NOTE
2. Be careful not to rest your arm on the air tube This will restrict the flow of air to the cuff 13 TAKING A MEASUREMENT 1 Press the ON OFF button All display symbols appear on the screen ON gt O bd e 2138788 tee 8 00 NOTE When the monitor completes the necessary preparations before measurement the Heartbeat Symbol 4 appears next to the zero Wait for the Heartbeat Symbol 48 before taking a measurement 2 Begin inflating the cuff by rapidly squeezing the inflation bulb until you have reached approximately 30 40 mmHg higher than your normal systolic reading If your normal systolic blood pressure is unknown inflate the cuff to 180 mmHg NOTES Do not inflate the arm cuff more than necessary The current time continues to be displayed while the cuff is being inflated Do not inflate higher than 299 mmHg 3 When the desired pressure has been achieved release the inflation bulb 14 NOTE If the re inflation symbol a TAKING A MEASUREMENT 4 Inflation stops and the measurement is started As the cuff deflates decreasing numbers appear on the display The Heartbeat Symbol 4 flashes at 4 Y E f every heartbeat i o an e mM 8 00 mM 8 00 Ly appears squeeze the inflation bulb to re inflate the arm cuff When the Deflation Symbol vw appears on the display press the Air Release Button to release the air left in the cuff The measurement is compl
3. Notas fuma es eder REE RAG rta Rida Bide Gide ane lata SS OS 23 E2 INTRODUCCI N Gracias por adquirir el monitor de presi n arterial con inflado manual Omron HEM 432C Complete lo siguiente para consulta futura FECHA DE COMPRA N MERO DE SERIE Engrape aqu su recibo de compra Su nuevo monitor de presi n arterial digital usa el m todo oscilom trico para la medici n de la presi n sangu nea Esto significa que el monitor detecta el movimiento de la sangre a trav s de la arteria braquial y convierte el movimiento en una lectura digital Un monitor oscilom trico no necesita un estetoscopio de modo que su uso es sencillo El HEM 432C cuenta con los siguientes componentes Monitor Brazalete Estandar 9 13 circunferencia del brazo e Pera de insuflaci n Manual de instrucciones en ingl s y espa ol El monitor de presi n arterial de inflado manual HEM 432C est destinado al uso en el hogar GUARDE ESTAS INSTRUCCIONES E3 NOTAS DE SEGURIDAD IMPORTANTES A fin de garantizar el uso adecuado del producto se deben aplicar siempre medidas de seguridad b sicas incluyendo las precauciones que se enumeran a continuaci n M Lea toda la informaci n del manual de instrucciones y cualquier otro material impreso incluido en la caja antes de usar la unidad MI P ngase en contacto con el m dico para obtener informaci n espec fica acerca de su presi n arterial Siga las instrucciones del m di
4. Retire el brazalete para el brazo i Lea C mo tomar una medici n en la p gina 14 El brazalete est Espere 2 3 minutos Tome otra demasiado inflado medici n Cambie las cuatro bater as Consulte la p gina 8 con respecto a la instalaci n de las bater as INDICADORES DE ERROR No hay alimentaci n el ctrica Cambie todas las baterias gastadas Las bater as est n gastadas Parpadeando o Fija CAUSAS Y SOLUCIONES No aparece ninguna Verifique la instalaci n de las bater as visualizaci n en la unidad para ver si las polaridades de las bater as est n correctamente colocadas La presi n arterial var a constantemente Muchos factores incluyendo el estr s la hora del d a la forma en que se coloca el brazalete pueden afectar su presi n arterial Repase las secciones Antes de tomar una medici n y C mo tomar una medici n Los valores de medici n parecen ser demasiado altos o demasiado bajos E19 DECLARACION DE LA FCC INFORMACION DE LA GARANTIA Nota POTENCIAL DE INTERFERENCIA DE RADIO TELEVISION para EE UU solamente Este producto ha sido probado y cumple con los limites de un dispositivo digital de Clase B de acuerdo con la parte 15 de las normas FCC Estos l mites fueron dise ados para proporcionar una protecci n razonable contra interferencias perjudiciales cuando se utilice el equipo en una instalaci n residencial El producto genera uti
5. have other rights which may vary from state to state FOR CUSTOMER SERVICE Visit our web site at www omronhealthcare com Call toll free 1 800 634 4350 21 SPECIFICATIONS Model Omron HEM 432C Display LCD Digital Display Measurement Range Pressure 0 to 299 mmHg Pulse 40 180 min Accuracy Calibration Pressure 3mmHg or 2 of reading Pulse 5 of reading Inflation Manual by inflation bulb Deflation Automatic pressure release valve Rapid Air Release Manual release valve Pressure Detection Capacitive pressure sensor Measurement Method Oscillometric method Pulse Wave Detection Capacitance type pressure sensor Power Source 4 AAA batteries Battery Life Approx 600 uses when used twice a day with new AAA standard manganese batteries Operating Temperature Humidity 50 F to 104 F 10 C to 40 C 30 to 85 RH Storage Temperature Humidity 4 F to 140 F 20 C to 60 C 10 to 95 RH Main Unit Weight Approximately 7 3 8 oz 210 g not including batteries Main Unit Dimensions Approx 4 1 8 w x 3 1 8 h x 5 3 8 1 106 mm x 80 mm x 136 mm Cuff Size Approximately 5 3 4 w x 17 1 2 1 146 mm x 446 mm Cuff tube 23 5 8 1 600 mm Cuff Circumference Fits arm circumferences 9 to 13 220mm to 320mm Contents Main Unit Arm Cuff Inflation Bul
6. s recientes HACIENDO UN PROMEDIO DE LA FUNCI N El monitor tambi n calcula una lectura media basada en los valores de las tres medidas m s recientes que fueron tomadas en el plazo de 10 minutos de la lectura m s reciente Notas e Si s lo se guardan dos lecturas en la memoria para el per odo de 10 minutos el promedio se basa en las dos lecturas Si se guarda una lectura en la memoria para el per odo de 10 minutos esta lectura se visualiza como promedio Si la fecha y la hora no es ajustada los valores de la medida y el valor medio no ser n almacenados en la memoria correctamente PARA MOSTRAR EL VALOR PROMEDIO of lal Simbolo de valor promedio 1 Presione el bot n ON OFF Encendido Apagado para encender el monitor 2 Presione el bot n de la MEMORY Memoria El s mbolo de valor promedio aparece en la pantalla con la lectura promedio USO DE LA FUNCI N MEMORIA PARA MOSTRAR LOS VALORES DE MEDICI N La fecha y hora se visualizan alternativamente con los valores de medici n 1 Presione el bot n MEMORY Memoria mientras se visualiza el s mbolo de valor promedio i Se visualizan los valores de medici n m s recientes Notas Presione reiteradamente el bot n para mostrar los valores siguientes e Presione y mantenga presionado el bot n para visualizar los valores m s r pidamente 2 Presione el bot n ON OFF Encendido Apagado para apagar el monitor PARA BORRAR TODOS LOS VALORE
7. 432CN2INST Rev
8. CONFIGURACI N DE LA HORA La hora se configura con AM o PM Presione el boton MEMORY Memoria para avanzar con incrementos de una hora Presione el bot n de Configuraci n de la fecha hora para establecer la hora actual Los minutos parpadean en la pantalla 6 CONFIGURACI N DE LOS MINUTOS Presione el bot n MEMORY Memoria para avanzar con incrementos de un minuto Presione el bot n de Configuraci n de la fecha hora para establecer los minutos actuales La unidad est lista para tomar la medida Notas Al hacer ajustes a la Fecha Hora apriete el bot n ON OFF Apriete el bot n de Fecha Hora Cuando termine apriete el bot n ON OFF para apagar la unidad Ell COLOCACION DE EL BRAZALETE PARA EL BRAZO 1 Conecte el tubo de aire de el brazalete para el brazo y la pera de insuflaci n a los enchufes del aire 2 Retire las ropas ajustadas de la parte superior del brazo ASS 3 Si ntese en una silla con los pies apoyados en el piso Coloque su brazo en una mesa de modo que el brazalete quede al mismo nivel que su coraz n El2 COLOCACI N DE EL BRAZALETE PARA EL BRAZO 4 Coloque el brazalete en la parte superior del brazo izquierdo de modo que la flecha azul quede centrada en la parte interna del brazo y alineada con el dedo medio El tubo de aire corre hacia abajo por la parte interna del brazo La parte inferior de el brazalete debe quedar aproximadamente a 1 2 1 27 cm por e
9. OMRON Manual Inflation Blood Pressure Monitor Model HEM 432C ENGLISH ESPA OL CONTENTS Before Using the Monitor Introduction arsenales Peewee Ge tS 3 Important Safety Notes 0 0 cece eee eee 4 Before Taking a Measurement 00 00 e ee ee eee 5 Operating Instructions Know Your Uit isese sinanengin cette eee 6 Unit EA A Sd Sales o a eae 7 Battery Installation s ea ede eee ee eee eee 8 Setting the Date and Time 0 0 0 0 e eee 9 Applying the Arm Cuff 0 2 eee ee eee 12 Taking a Measurement 0 0c eee eee eee eee 14 Using the Memory Function e Averaging Function 0 00 ee eee eee 16 e Measurement Values 0 000 e eee 17 Care and Maintenance Care and Maintenance 0 c eee cee eee 18 Error Indicators and Troubleshooting Tips 19 ECC Statement mii Pn tise BE ee RO ee E Rg demais eS 20 Warranty Information 000 cc cece eee eee 21 Specifications o HOG ON ale eae 22 Notes cc aia Da Slap ais O 23 2 INTRODUCTION Thank you for purchasing the Omron HEM 432C Manual Inflation Blood Pressure Monitor Fill in for future reference DATE PURCHASED SERIAL NUMBER Staple your purchase receipt here Your new digital blood pressure monitor uses the oscillometric method of blood pressure measurement This means the monitor detects your blood s movement through your brach
10. S QUE SE GUARDAN EN LA MEMORIA No puede borrar parcialmente los registros que se guardan en la memoria Se borran todos los registros 1 Presione el bot n ON OFF Encendido Apagado 2 Presione y mantenga presionado el bot n MEMORY Memoria y el bot n ON OFF Encendido Apagado simult neamente durante m s de 2 segundos val 69 vaj 87 00 El7 CUIDADO Y MANTENIMIENTO Para mantener el monitor de presi n arterial digital en las mejores condiciones y proteger a la unidad de modo que no se da e siga estas instrucciones No doble el brazalete ni el tubo de aire por la fuerza No doble los elementos de modo que queden demasiado apretados Limpie el monitor con un pa o seco y suave No use limpiadores abrasivos o vol tiles No trate de limpiar el brazalete Nunca sumerja el monitor ni ninguno de los componentes en agua Guarde el monitor en un lugar seco y seguro No someta al monitor a temperaturas extremas altas o bajas humedad y luz directa del sol Evite someter al monitor a golpes fuertes como por ejemplo dejar caer la unidad al suelo Saque las bater as si no piensa utilizar la unidad durante tres meses o un per odo m s prolongado Cambie siempre todas las bater as por bater as nuevas al mismo tiempo Use la unidad de acuerdo con las instrucciones que se suministran en este manual Use s lo las piezas y los accesorios autorizados E18 INDICADORES DE ERROR S MBOLO CAUSA CORRECCI N o i
11. asurement values The monitor also calculates an average reading based on the three most recent measurements taken within 10 minutes of the last reading NOTES If only two readings are stored in the memory for the 10 minute period the average is based on the two readings If one reading is stored in the memory for the 10 minute period this reading is displayed as the average 1 TO START THE SETTING Press the ON OFF button ui qo j ER PuLSE 2 OFF mi 2g 05 The year flashes on the display l aa Cher SETTING THE DATE AND TIME 2 SETTING THE YEAR The year can be set between 2005 and 2030 When the display reaches 2030 it will return to 2005 Press the MEMORY button to advance by increments of one year Press the Date Time Setting button to set the current year The month flashes on the display NOTE Press and hold the MEMORY button to advance the date and time values faster 3 SETTING THE MONTH Creio qa j puse j e 2005 df ey C Press the MEMORY button to advance by increments of one month Press the Date Time Setting button to set the current month The day flashes on the display 4 SETTING THE DAY Press the MEMORY button to advance by increments of one day Press the Date Time Setting button to set the current day The hour flashes on the display 10 SETTING THE DATE AND TIME 5 SETTING THE HOUR The time is set using
12. b and Instruction Manual UPC Code 0 73796 04322 3 NOTE These specifications are subject to change without notice 22 NOTES 23 Distributed by OMRON HEALTHCARE INC 1200 Lakeside Drive Bannockburn Illinois 60015 www omronhealthcare com Manufactured by Omron Made in China Copyright 2005 Omron Healthcare Inc HEM 432CN2INST Rev OMRON Monitor de presi n arterial con inflado manual Modelo HEM 432C ESPANOL CONTENIDO Antes de usar el monitor Introduce On Ta AAA AA A ASAE 3 Notas de seguridad importantes 0 00 00004 4 Antes de tomar una medici n 0 0 eee 5 Instrucciones de funcionamiento Conozca su unidad susmono e ele s beeta Pape ay doge JAn Ya 6 Pantalla de la unidad 0 eee eee eee 7 Instalaci n del brazalete 0 2 eee ee eee 8 Configuraci n de la fecha y hora 2 0 00 0 eee 9 Colocaci n de la banda para el brazo 4 12 Como tomar una medici n sueeos ereere ee eee 14 Uso de la funci n Memoria e Funci n de promedio 0 000000 16 e Valores de la medida 000000 17 Cuidado y mantenimiento Cuidado y mantenimiento o ooooocoocccocccc eee eee 18 Indicadores de error y soluci n de problemas 19 Declaraci n de la FCC css ce oe rr a 20 Informaci n sobre la garantia 0 2 0 2 eee eee eee 21 Especificaciones ci did ie td e Sa pia 22
13. batteries with new ones at the same time Use the unit consistent with the instruction provided in this manual Use only authorized parts and accessories 18 ERROR INDICATORS SYMBOL CAUSE CORRECTION E E Cuff under inflated Remove the arm cuff Read Taking a Measurement on page 14 Cuff over inflated Wait 2 3 minutes Take another F measurement xl Batteries are worn Replace the four batteries Refer Blinking or Steady to page 8 for battery installation TROUBLESHOOTING TIPS CAUSES AND SOLUTIONS No power Replace worn batteries No display appears on the unit Check the battery installation for proper placement of the battery polarities Blood pressure varies constantly Many factors including stress time of day how you wrap the cuff may affect your blood pressure Review the sections Before Taking a Measurement and Taking a Measurement Measurement values appear too high or too low FCC STATEMENT NOTE POTENTIAL FOR RADIO TELEVISION INTERFERENCE for U S A only This product has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation The product generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interfere
14. bol bs EE v gt ES Qu ca me co ca Low Battery Symbol Date Time Display Reinflation Symbol Components Air Tube E Air Tube Arm Cuff Air Release Button Inflation Bulb BATTERY INSTALLATION 1 Press the A indicator on the battery cover and slide the cover off in the direction of the arrow 2 Install 4 AAA size batteries so the positive and negative polarities match the polarities of the battery compartment as indicated 3 Replace the battery cover BATTERY REPLACEMENT Low Battery Indicator When the Low Battery Symbol appears on the display screen remove all the batteries Replace with four new batteries at the same time When the Low Battery Symbol blinks a brief period of usage remains Long life alkaline batteries are recommended NOTES Measurement values stored in the memory will not be deleted during battery replacement After replacing the batteries reset the date and time Refer to page 9 Setting the Date and Time Dispose of batteries according to applicable local regulations 8 SETTING THE DATE AND TIME Set the monitor to the current date and time before taking a measurement for the first time If the correct date and time is not set the measurement values stored in the memory and the average value will not be correct The Blood Pressure Monitor automatically stores up to 30 me
15. co M Opere la unidad s lo para el uso para el cual est destinada No la use para ning n otro prop sito M La unidad est dise ada para ser utilizada para medir la presi n arterial y el pulso en la poblaci n de pacientes adultos No se debe usar en ni os peque os M No use ning n tel fono celular cerca de la unidad Esto puede g p provocar fallas en el funcionamiento M Los cambios o las modificaciones que no hayan sido aprobados por el fabricante anular n la garant a del usuario No desarme ni trate de reparar la unidad ni los componentes E4 ANTES DE TOMAR UNA MEDICI N A fin de garantizar una lectura confiable siga estas recomendaciones 1 Evite alcohol el comer el beber el fumar el ejercitar y el ba arse para 30 minutos antes de tomar una medici n Descanse durante al menos 15 minutos antes de tomar la medici n 2 El estr s eleva la presi n sangu nea Evite tomar mediciones durante aquellos momentos en los que se sienta estresado 3 Las mediciones se deben llevar a cabo en un lugar tranquilo 4 Retire la ropa ajustadas de su brazo izquierdo 5 Si ntese en una silla con los pies apoyados en el piso Coloque su brazo izquierdo sobre una mesa de modo que el brazalete quede al mismo nivel que su coraz n 6 Qu dese quieto y no hable durante la medici n 7 Lleve un registro de su presi n arterial y de las lecturas del pulso para que las vea su m dico Una sola medici n no brinda una i
16. e presi n arterial Omron HEM 432C y el brazalete del monitor est n garantizados de estar como libre de defectos en materiales y mano de obra que se presenten dentro de un a o a partir de la fecha de compra si el monitor se usa de acuerdo con las instrucciones que se suministran con el monitor Las garant as a las que se hace referencia anteriormente se extienden s lo al comprador minorista original Seg n la opci n de la empresa se reparar o cambiar sin cargo alguno el monitor o la banda del monitor que est n cubiertos por las garant as a las que se hace referencia anteriormente La reparaci n o el reemplazo constituye la exclusiva responsabilidad de nuestra empresa y su nico recurso conforme a las garant as a las que se hace referencia anteriormente Para recibir el servicio de garantia p ngase en contacto con el servicio de atenci n al cliente de Omron Healthcare llamando al 1 800 634 4350 para obtener la direcci n donde se realizan las reparaciones y las tarifas de env o y manipulaci n La informaci n con respecto al servicio de garant a est disponible en nuestro sitio Web en www omronhealthcare com Adjunte un comprobante de compra Incluya una carta con su nombre direcci n n mero de tel fono y la descripci n del problema espec fico Empaque el producto cuidadosamente para evitar que se da e durante el traslado Dado que existe la posibilidad de p rdida durante el traslado le recomendamos que asegure el prod
17. ement Rest for at least 15 minutes before taking the measurement 2 Stress raises blood pressure Avoid taking measurements during stressful times 3 Measurements should be taken in a quiet place 4 Remove tight fitting clothing from your left arm 5 Sit in a chair with your feet flat on the floor Rest your left arm on a table so that the cuff is at the same level as your heart 6 Remain still and do not talk during the measurement 7 Keep a record of your blood pressure and pulse readings for your physician A single measurement does not provide an accurate indication of your true blood pressure You need to take and record several readings over a period of time Try to measure your blood pressure at the same time each day for consistency 8 Wait 2 3 minutes between measurements The wait time allows the arteries to return to the condition prior to taking the blood pressure measurement You may need to increase the wait time depending on your individual physiological characteristics KNOW YOUR UNIT UNIT DISPLAY Main Unit Display ON OFF Button Systolic Blood Pressure Battery Compartment Diastolic Blood Pressure Date Time Setting Button mn MM 1 a aS lt SA D A rr MU N MN MEMORY Button Memory Symbol a Heartbeat Symbol Pulse Display T Deflation Symbol Cuff Air Plug Bulb Air Plug Average Value Sym
18. eriores a los de la ltima lectura Notas e Si s lo se guardan dos lecturas en la memoria para el per odo de 10 minutos el promedio se basa en las dos lecturas Si se guarda una lectura en la memoria para el per odo de 10 minutos esta lectura se visualiza como el promedio 1 PARA COMENZAR EL AJUSTE Apriete el bot n ON OFF cr qu y PULSE mis cll OFF El a o titila en la pantalla OC E9 Nota CONFIGURACION DE LA FECHA Y HORA CONFIGURACION DEL ANO El a o se puede configurar entre 2005 y 2030 De E E mo 2005 6c Cuando la pantalla llega a 2030 vuelve a 2005 Presione el bot n MEMORY Memoria para avanzar con incrementos de un a o Presione el bot n de Configuraci n de la fecha hora para establecer el a o actual El mes titila en la pantalla e Presione y mantenga presionado el bot n MEMORY Memoria para avanzar los valores de fecha y hora m s r pidamente CONFIGURACI N DEL MES Presione el bot n MEMORY Memoria para avanzar con incrementos de un mes Presione el bot n de Configuraci n de la fecha hora para establecer el mes actual El d a parpadea en la pantalla CONFIGURACI N DEL D A Presione el bot n MEMORY Memoria para avanzar con incrementos de un d a Presione el bot n de Configuraci n de la fecha hora para establecer el d a actual La hora parpadea en la pantalla E10 CONFIGURACION DE LA FECHA Y HORA 5
19. ete the Heartbeat Symbol 4 stops flashing and your blood pressure and pulse rate are displayed Systolic Blood _ _ o Pressure i Diastolic Blood no Pressure e 0 8 00 Pulse Display Press the ON OFF button to turn the monitor off NOTE The monitor will automatically turn off after five minutes 15 USING THE MEMORY FUNCTION Every time you complete a measurement the monitor stores the blood pressure and pulse rate in the memory The Blood Pressure Monitor automatically stores up to 30 measurement values When 30 sets of measurement values are stored in the memory the oldest record is deleted to save the most recent measurement values AVERAGING FUNCTION The monitor also calculates an average reading based on the values of the three most recent measurements that were taken within 10 minutes of the most recent reading NOTES e If only two readings are stored in the memory for the 10 minute period the average is based on the two readings If one reading is stored in the memory for the 10 minute period this reading is displayed as the average If the date and time is not set the measurement values and the average value will not be stored in the memory correctly TO DISPLAY THE AVERAGE VALUE of Tar Average Value Symbol i 8 y 1 Press the ON OFF button to turn the power on 2 Press the MEMORY button The average value symbol will display on the screen with the average readi
20. i n de presi n Sensor de presi n capacitivo M todo de medici n M todo oscilom trico Detecci n del pulso Sensor de presi n de tipo de capacitancia Fuente de alimentaci n 4 bater as AAA Vida til de la bater a Aproximadamente 600 usos si se usa dos veces por d a con bater as de manganeso AAA nuevas Temperatura de funcionamiento Humedad 50 F a 104 F 10 C a 40 C 30 a 85 RH Temperatura de almacenamiento Humedad 4 F a 140 F 20 C a 60 C 10 a 95 RH Peso de la unidad principal Aproximadamente 7 3 8 onzas 210 g sin incluir las bater as Dimensiones de la unidad principal Aproximadamente 4 1 8 ancho x 3 1 8 alto x 5 3 8 largo 106 mm x 80 mm x 136 mm Tama o del brazalete Aproximadamente 5 3 4 ancho x 17 1 2 largo 146 mm x 446 mm Tubo de la banda 23 5 8 largo 600 mm Circunferencia del brazalete Se adapta a una circunferencia de brazo de 9 a 13 220mm a 320mm Contenido Unidad principal brazalete para el brazo bulbo de la inflaci n y manual de instrucci nes C digo UPC 0 73796 04322 3 NOTA Estas especificaciones est n sujetas a cambio sin previo aviso E22 NOTES E23 Distribuido por OMRON HEALTHCARE INC 1200 Lakeside Drive Bannockburn Illinois 60015 www omronhealthcare com Fabricado por Omron Hecho en China Copyright 2005 Omron Healthcare Inc HEM
21. ial artery and converts the movements into a digital reading An oscillometric monitor does not need a stethoscope so the monitor is simple to use The HEM 432C comes with the following components Monitor Standard Cuff 9 13 arm circumference Inflation Bulb Instruction Manual in English and Spanish The HEM 432C Manual Inflation Blood Pressure Monitor is intended for home use SAVE THESE INSTRUCTIONS 3 IMPORTANT SAFETY NOTES To assure the correct use of the product basic safety measures should always be followed including the precautions listed below M Read all information in the instruction book and any other literature included in the box before using the unit Y Contact your physician for specific information about your blood pressure Follow the instructions of your healthcare provider M Operate the unit only as intended Do not use for any other purpose M The unit is intended for use in measuring blood pressure and pulse rate in adult patient population Do not use on infants M Do not use a cellular phone near the unit It may result in operational failure Y Changes or modifications not approved by the manufacturer will void the user warranty Do not disassemble or attempt to repair the unit or components BEFORE TAKING A MEASUREMENT To ensure a reliable reading follow these recommendations 1 Avoid eating drinking alcohol smoking exercising and bathing for 30 minutes before taking a measur
22. liza y puede irradiar energ a de radiofrecuencia y si no se instala y utiliza de acuerdo con las instrucciones puede provocar interferencias perjudiciales en las comunicaciones por radio Sin embargo no hay garant as de que no se producir n interferencias en una instalaci n en particular Si el producto provoca interferencias perjudiciales a la recepci n de radio o televisi n lo que se puede determinar encendiendo y apagando el equipo se sugiere que el usuario intente corregir la interferencia a trav s de una o m s de las siguientes medidas Reoriente o reubique la antena receptora Aumente la distancia entre el equipo y el receptor Conecte el equipo a un tomacorrientes que est en un circuito distinto de aqu l al que se encuentra conectado el receptor Consulte al distribuidor o a un t cnico experimentado en radio TV para obtener m s informaci n POTENCIAL DE INTERFERENCIA DE RADIO TELEVISI N para Canad solamente Este aparato digital no excede los l mites de Clase B para las emisiones de ruido deradio de los dispositivos digitales como se establece en la norma con respecto a equipos que causan interferencia denominada Dispositivos digitales ICES 003 del Departamento Canadiense de Comunicaciones Los cambios o las modificaciones que no est n expresamente aprobados por la parte responsable encargada del cumplimiento pueden anular la autoridad del usuario para operar el equipo E20 El monitor d
23. nce to radio communications However there is no guarantee that interference will not occur in a particular installation If the product does cause harmful interference to radio or television reception which can be determined by turning the product on and off the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the product and the receiver Connect the product into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help POTENTIAL FOR RADIO TELEVISION INTERFERENCE for Canada only This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of the Canadian Department of Communications Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment 20 WARRANTY INFORMATION LIMITED WARRANTY Your Omron HEM 432C Blood Pressure Monitor and the monitor cuff are warranted to be free from defects in materials and workmanship appearing within one year from the date of purchase when the monitor is used in accordance with the instructions provided with the monitor The above warranties exte
24. ncima del codo 1 2 pulgada 1 2 cm Fl dha 5 Coloque el brazalete de modo que quede bien envuelta alrededor del brazo usando la correa de cierre Tubo de aire COLOCACI N DEL BRAZALETE PARA EL BRAZO EN EL BRAZO DERECHO Coloque la bunda en la parte superior del brazo derecho de modo que la flecha azul y el tubo de aire corran por la parte interna del brazo La parte inferior de la bunda debe quedar aproximadamente a 1 2 1 27 cm por encima del codo e es Nota Tenga cuidado de no apoyar el brazo sobre el tubo de aire Esto impedir el flujo de aire hacia el brazalete El3 COMO TOMAR UNA MEDICION 1 Presione el bot n ON OFF Encendido Apagado Todos los s mbolos de visualizaci n aparecen en la pantalla Nota Cuando el monitor completa los preparativos necesarios para la medici n el s mbolo de coraz n 4 aparece al lado del cero Espere hasta que aparezca el s mbolo de coraz n 4 antes de tomar una medici n 2 Comience a inflar el brazalete apretando r pidamente la pera de insuflaci n hasta que llegue aproximadamente a 30 40 mmHg por encima de su lectura sist lica normal Si desconoce cu l es su presi n arterial sist lica normal infle el brazalete hasta 180 mmHg Notas e No infle el brazalete para el brazo m s de lo que sea necesario La hora actual se sigue visualizando mientras el brazalete se infla No infle m s arriba de 299 mmHg 3 Una vez que haya alca
25. nd only to the original retail purchaser We will at our option repair or replace without charge any monitor or monitor cuff covered by the above warranties Repair or replacement is our only responsibility and your only remedy under the above warranties To obtain warranty service contact Omron Healthcare s Customer Service by calling 1 800 634 4350 for the address of the repair location and the return shipping and handling fee Information for warranty service is available on our website at www omronhealthcare com Enclose the Proof of Purchase Include a letter with your name address phone number and description of the specific problem Pack the product carefully to prevent damage in transit Because of possible loss in transit we recommend insuring the product with return receipt requested ALL IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE ARE LIMITED TO THE DURATION OF THE APPLICABLE WRITTEN WARRANTY ABOVE Some provinces do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you OMRON SHALL NOT BE LIABLE FOR LOSS OF USE OR ANY OTHER INCIDENTAL CONSEQUENTIAL OR INDIRECT COSTS EXPENSES OR DAMAGES Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusions may not apply to you This warranty gives you specific legal rights and you may also
26. ndicaci n precisa de su verdadera presi n arterial Es necesario tomarse la presi n y registrar varias lecturas durante un per odo de tiempo Intente medir su presi n arterial todos los d as a la misma hora para obtener medidas coherentes 8 Espere 2 3 minutos entre cada medici n El tiempo de espera permite que las arterias vuelvan a la condici n en que estaban antes de tomar la medici n de la presi n arterial Es posible que sea necesario aumentar el tiempo de espera seg n sus caracter sticas fisiol gicas individuales ES CONOZCA SU UNIDAD Unidad principal Pantalla Bot n ON OFF Encendido Apagado y Compartimiento de la bater a Date Time Que fija El Bot n Bot n de MEMORIA Enchufe macho del aire Enchufe macho del aire Componentes Tubo de aire Brazalete para el brazo Tubo de aire Bot n de liberaci n de aire Pera de insuflaci n E6 PANTALLA DE LA UNIDAD Presi n arterial sist lica D Lt e UM as ua as S mbolo de latidos Presi n arterial diast lica E del coraz n D oo _ oy O S mbolo de memoria en FE Ee 188 Indicador del pulso S mbolo de valor promedio ait La S mbolo de desinflado PmdB788 E Indicador de fecha hora S mbolo de bater a baja 4 S mbolo de reinflado E7 INSTALACI N DE LA BATER A 1 Presione el indicado
27. ng USING THE MEMORY FUNCTION TO DISPLAY THE MEASUREMENT VALUES The date and time is alternately displayed with the measurement values 1 Press the MEMORY button while the Average Value Symbol jij is displayed The most recent measurement values will be displayed NOTES e Press the button repeatedly to display the next values Press and hold the button to display the values faster 2 Press the ON OFF button to turn the power off TO DELETE ALL VALUES STORED IN THE MEMORY You cannot partially delete records stored in the memory All records will be deleted 1 Press the ON OFF button 2 Press and hold the MEMORY button and the ON OFF button simultaneously for more than 2 seconds CARE AND MAINTENANCE To keep your digital blood pressure monitor in the best condition and protect the unit from damage follow the directions listed below Do not forcefully bend the arm cuff or air tube Do not fold tightly Clean the monitor with a soft dry cloth Do not use any abrasive or volatile cleaners Do not attempt to clean the cuff Never immerse the monitor or any components in water Store the monitor in a safe and dry location Do not subject the monitor to extreme hot or cold temperatures humidity and direct sunlight Avoid subjecting the monitor to strong shocks such as dropping the unit on the floor Remove the batteries if the unit will not be used for three months or longer Always replace all the
28. nzado la presi n deseada deje de apretar la pera de insuflaci n El4 C MO TOMAR UNA MEDICI N El inflado se detiene y se inicia la medici n A medida que el brazalete se desinfla aparecen n meros en la pantalla en orden decreciente El s mbolo de NIE f J coraz n 4 parpadea ante cada latido J gt O l c del corazon Nota Si aparece el s mbolo a de volver a inflar apriete la pera de insuflaci n para volver a inflar el brazalete para el brazo Cuando el s mbolo de desinflado e aparece en la pantalla presione el bot n de liberaci n de aire para eliminar el aire que queda en el brazalete La medici n se ha completado el s mbolo de coraz n 4 deja de parpadear y se visualiza la presi n arterial y la velocidad del pulso Presi n arterial _ sist lica Presi n arterial diast lica Pantalla de visualizaci n del pulso 7 Presione el bot n ON OFF Encendido Apagado para apagar el monitor Nota El monitor se apaga autom ticamente despu s de cinco minutos E15 USO DE LA FUNCION MEMORIA Cada vez que complete una medici n el monitor guarda la presi n arterial y la velocidad de la onda de pulso en la memoria El monitor de presi n arterial guarda autom ticamente hasta 30 valores de medici n Una vez que se guardan 30 conjuntos de valores de medici n en la memoria el registro m s antiguo se borra para guardar los valores de medici n m
29. r A que aparece en la cubierta de la bater a y deslice la cubierta en la direcci n que indica la flecha 2 Instale 4 bater as de tama o AA de modo que las polaridades positiva y negativa concuerden con las polaridades que se indican en el compartimiento de la bater a 3 Vuelva a colocar la cubierta de la bater a CAMBIO DE LA BATER A 4x1 Indicador de bater a baja Cuando el indicador de bater a baja aparece en la pantalla retire todas las bater as Cuando el s mbolo de la bateria parpadea queda un periodo breve de uso Se recomienda usar bater as alcalinas de larga duraci n Notas e Los valores de medici n que se guardan en la memoria no se borran durante el cambio de las bater as e Despu s de cambiar las bater as vuelva a ajustar la fecha y hora Consulte la p gina 9 Configuraci n de la fecha y hora Disponga de las bater as seg n regulaciones locales aplicables E8 CONFIGURACION DE LA FECHA Y HORA Ajuste la fecha y la hora actual en el monitor antes de tomar una medi da por primera vez Si la fecha y la hora no estan correctas los valores de la medida almacenada en la memoria y el valor medio no estar n correctos El monitor de presi n arterial guarda autom ticamente hasta 30 valores de medici n El monitor tambi n calcula una lectura promedio basada en las tres mediciones m s recientes que se tomaron dentro de los 10 minutos ant
30. ucto con el recibo de devoluci n solicitado TODAS LAS GARANT AS IMPL CITAS INCLUYENDO ENTRE OTRAS LAS GARANT AS IMPL CITAS DE COMERCIALIZACI N Y APTITUD PARA UN PROP SITO EN PARTICULAR SE LIMITAN A LA DURACI N DE LA GARANT A POR ESCRITO PERTINENTE QUE APARECE ANTERIORMENTE Algunas provincias no aceptan limitaciones en cuanto a la duraci n de una garant a impl cita de modo que es posible que la limitaci n anterior no se aplique en su caso OMRON NO SER RESPONSABLE POR LA P RDIDA DE USO O CUALQUIER OTRO COSTO GASTO O DA O INCIDENTAL O INDIRECTO Algunos estados no aceptan la exclusi n o limitaci n de los da os incidentales o indirectos de modo que es posible que las exclusiones anteriores no se apliquen en su caso Esta garant a le otorga derechos legales espec ficos y es posible que tambi n tenga otros derechos que pueden variar de un estado a otro PARA SERVICIO AL CLIENTE Visite nuestro sitio Web en www omronhealthcare com Llame sin cargo al 1 800 634 4350 E21 ESPECIFICACIONES Modelo Omron HEM 432C Pantalla Pantalla digital de LCD L mites de medici n Presi n 0 a 299 mmHg Pulso 40 180 min Precisi n Calibraci n Presi n 3mmHg o 2 de lectura Pulso 5 de lectura Inflado Manual por pera de insuflaci n Desinflado V lvula de liberaci n autom tica de presi n Liberaci n r pida de presi n V lvula de liberaci n manual Detecc

Download Pdf Manuals

image

Related Search

Related Contents

Samsung RL23DATW Инструкция по использованию  Conceptronic CNB75V19CARU  Emerson 644 User's Manual  台湾知的財産権関連事例と判決 2009  Ateliers du Bureau d`Aide à l`Insertion Professionnelle  safety and usage information user manual  ローダウン リアショックアブソーバー 取扱説明書  Sony DCR-TRV11 Operating Instructions  TV TFT LCD 10.2” ET LECTEUR DVD MANUEL D`UTILISATION  Cahier Georges Perec  

Copyright © All rights reserved.
Failed to retrieve file