Home

Descarregar

image

Contents

1. 2 1 2 2 2 3 2 4 2 5 3 1 3 2 3 3 3 4 Operation Instructions Smart Design In only one button Slide off the cover of the battery compartment located in the back of the unit and insert 3 AAA 1 5V batteries following the polarity indications Then close the cover Press the on button during 1 second The breath tester will emit a sound signal and the Wait WAIT message will appear on the screen At this time a countdown from 20 0 begins and the warm up process starts When the Wait WAIT message disappears you will hear a sound the screen shows Blow BLOW the icon of the car flashes and a series of ccc appear on the screen At this time you may begin the test Breath deeply before carrying out the test and blow directly into the mouthpiece until you hear a sound signal The digits O00 will flash during 4 seconds on the screen the message Blow BLOW will disappear and the result will appear in a few seconds The breath tester will emit a sound signal once the test has ended and the digital screen will show the result during a short period of time as follows If the result of the test is lower that the permitted level the icon of the car will only flash If the result of the test exceeds the permitted level the acoustic alarm will make a continuous noise and the message HI HIGH LEVEL and the icon No Driving will flash This result
2. Alcoholimetro de Precision Manual de Instrucciones Instructions Manual Manual de instruc es CONSUMER DESIGN PRODUCTS COP Manual de Instrucciones Manual de usuario para el alcoholimetro digital Zaphir CDP2000 Introducci n general El alcoholimetro Zaphir CDP2000 ha sido dise ado para medir la concentraci n de alcohol en una muestra de aire expirado Incluye un avanzado sensor NM Hot wire de extraordinaria sensibilidad y precisi n Adem s su moderno compacto y peque o disefio lo hacen muy manejable y practico como alcoholimetro de uso personal y profesional Cuando el contenido de alcohol supera el limite fijado el aparato emite una se al ac stica y un mensaje de alerta en su pantalla Caracteristicas Principales Avanzado sensor de alcohol NM Hot wire Gran rapidez de respuesta Montaje mediante ensamblado SMD que garantiza una respuesta estable Dise ado con Modo Inteligente Indicadores precisos de forma digital en pantalla Pantalla digital con luz azul de fondo Dise o moderno y manejable Avisos ac sticos y digitales Sistema Auto check ise ado con sistema inteligente de ahorro de energ a Datos t cnicos Tipo de sensor NM Hot wire sensor de ltima generaci n Rango de medidas 0 00 1 00mg L 0 00 0 20 BAC 0 00 2 00g L 0 00 2 00 OBAC Nivel de alarma 0 25mg L 0 05 BAC 0 50g L 0 50 0BAC Precision desviaci n estandar de la reproducibilidad inferior
3. citas en relaci n a la utilizaci n del aparato 4 La responsabilidad se limita solamente al coste del aparato La garant a tiene una duraci n de 6 meses desde la fecha de compra de la unidad contra cualquier defecto de fabricaci n En caso de necesitar soporte t cnico por cualquier motivo garant a y consultas sobre el funcionamiento puede contactar con el departamento de Atenci n al Cliente de CDP llamando al tel fono 902 10 40 60 oa trav s de nuestra Web www cdpsa es donde recibir instrucciones precisas de c mo proceder al respecto Otros muchos factores aliento tabaco calidad del aire etc pueden afectar a la medici n as que tome los valores s lo como referencia Instructions Manual Zaphir CDP2000 Breath Tester instructions General introduction The Zaphir CDP2000 breath tester has been designed to measure the concentration of alcohol in a sample of exhaled air It includes an advanced sensor NM Hot wire of extraordinary sensibility and precision Its modern compact and small design makes it very manageable and practical as personal or professional use breath tester When the alcohol content exceeds the preset limit the device issues a sound signal and shows an alert message on the screen Main Characteristics Advanced alcohol sensor NM Hot wire Fast response Assembly by means of SMD that guarantees a stable response Designed with Intelligent Mode Precise on screen digital indicators
4. sensor de Itima gera o Gama de detec o 0 00 1 00mg L 0 00 0 20 BAC 0 00 2 00g L 0 00 2 00 OBAC N vel de alarme 0 25mg L 0 05 BAC 0 50g L 0 50 BAC Precis o desvio padr o inferior a 0 01mg L no grau de medida de O a 0 5 mg L Tempo de resposta lt 5 seg Tempo de aquecimento lt 20 seg Bateria DC4 5V 3xAAA Pilhas Electricidade lt 120ma 13 14 Temperatura de funcionamento 10 50 Humidade relativa lt 95 Ecra de 3 digitos com luz azul de fundo Dimens es 103x65x27mm CxLxAl Peso lt 64 g sem pilhas Vida til aproximada da bateria gt 200 testes 1 Estrutura e Instru es 1 1 Foto 1 1_ amp 3 1 1 Simbolos no ecra N o conduzir Espere gt Teste gt Informa es digitais Boquilha Orif cio de som Bot o de acender A O N Entrada para liga o ao transformador Ecr digital oo Orif cio de ventila o Estado das bater as lt Nivel alto Unidade de medida lt Sopre lt Resultado Foto 2 0 00 Conte do de lcool em formato mg L com 3 d gitos 20 seg Conta atr s Aquecimento Contagem decrescente SGF Pronto para soprar Fase de soprar 000 intermitente A analisar a amostra FFF Erro no sensor ou sensor saturado 2 1 2 2 2 3 2 4 2 5 3 1 3 2 Manual de Instru es Smart Design T
5. Digital screen with blue backlight Modern and manageable design Acoustic and digital warnings Auto check system Designed with energy saving intelligent system Technical data Sensor type high tech NM Hot wire sensor Range of measurement 0 00 1 00mg L 0 00 0 20 BAC 0 00 2 00g L 0 00 2 00 OBAC Alarm level 0 25mg L 0 05 BAC 0 50g L 0 50 BAC Precision standard deviation less than 0 01mg L in the measurement range from 0 to 0 5 mg L Response time lt 5 sec Warm up time lt 20 sec Consumption DC4 5V 3xAAA Batteries Current lt d120mA 7 Operation temperature 10 50 Relative humidity lt 95 Screen 3 digits with blue backlight Dimensions 103x65x27mm LaxAnxAl lt 64 grams without batteries Approximate useful life of batteries gt 200 tests 1 Structures and Operation Guide 1 1 Picture 1 1 Y Mouthpiece Speaker On button A O N Hole for external power Digital screen oo Ventilation orifice 3 Picture 1 1 1 Operation Guide lt Battery status High level Measurement unit Do not drive Wait Test 9 Picture 2 Digital indications 0 00 Alcohol Content in mg L format with 3 digits 20sec countdown Warm up Countdown g Ready to blow Blowing phase 000 flashing Conversion in work mode and result analysis FFF Failure in the sensor or saturated sensor
6. a dissolventes ou quaisquer outros produtos de limpeza poderiam avariar o aparelho Solu es para problemas comuns FALHA CAUSA PROV VEL SOLU O O ecr n o acende Pilhas mal colocadas Coloque as pilhas correctamente tendo em considera o 0 alinhamento Pilhas gastas Substitua as pilhas Avaria no circuito Contacte o suporte t cnico N o detecta a presen a de lcool N o foi completado o processo de aquecimento Antes de efectuar a an lise aguarde at terminar 0 processo de pr aquecimento Avaria no circuito Contacte o suporte t cnico No ecr aparece o s mbolo FFF e o aparelho desliga automaticamente Avaria no sensor Contacte o suporte t cnico O ecr indica que as pilhas est o em baixo e apaga automaticamente Pilhas gastas Substitua as pilhas Precau es 1 O fabricante distribuidor n o se responsabiliza da utiliza o deste aparelho Este alcool metro nunca deve ser empregue com a finalidade de efectuar testes validados pelas for as de seguran a porque podem n o estar legalmente reconhecidos O medidor de lcool um aparelho de preven o e despistagem e os resultados devem ser considerados unicamente como uma medida orientadora N o conduza ou manipule m quinas se suspeitar ou tem raz es para supor que o seu comportamento pode estar a sofrer altera es pelo consumo de lcool mesmo que o teste indi
7. a 0 01mg L en el rango de medida de 0 a 0 5 mg L Tiempo de respuesta lt 5 seg Tiempo de calentamiento lt 20 seg Consumo DC4 5V 3AAA Bater as corriente lt 120mA Temperatura de funcionamiento 10 50 Humedad relativa lt 95 Pantalla de 3 digitos con luz azul de fondo Dimensiones 103 x 65 x 27mm La x An x Al lt 64 grms sin baterias Vida til aproximada de las baterias gt 200 pruebas 1 Estructura y Guia de funcionamiento 1 1 Foto 1 y Boquilla Orificio altav z Bot n encendido A N Orificio para alimentaci n externa Pantalla digital oo Orificio de ventilaci n Foto 1 3 1 1 Gu a de funcionamiento Estado de las bater as lt Nivel alto Unidad de medida No conducir gt Espere gt Sople Test gt lt Resultado Foto 2 Indicaciones digitales 0 00 Contenido de alcohol en formato mg l con 3 digitos 20 seg Cuenta atr s Calentamiento Cuenta atras O Listo para soplar Fase de soplado 000 parpadeando Conversi n del modo de trabajo y an lisis de los resultados FFF Fallo en el sensor o sensor saturado 2 1 2 2 2 3 2 4 2 5 3 1 3 2 Operation instruction Smart Desing Todo en un solo bot n Deslice la tapa del compartimiento de las pilas situada en la parte trasera del aparato e inserte 3 pilas del tipo AAA 1 5V sigui
8. endo las indicaciones de polaridad Despu s cierre la tapa Presione el bot n de encendido durante 1 segundo El alcoholimetro emitir una sefial ac stica y el mensaje Wait ESPERE aparecer en pantalla A partir de este momento comienza una cuanta atras de 20 0 y se inicia el proceso de pre calentamiento Cuando el mensaje Wait ESPERE desaparezca suene una sefial ac stica la pantalla indique Blow SOPLE el icono del coche parpadee y aparezca una sucesi n de ccc en la pantalla entonces podra comenzar su prueba Respire profundamente antes de realizar el test y sople directamente por la boquilla hasta que suene una se al ac stica Los d gitos 000 parpadear n durante 4 segundos en la pantalla el mensaje Blow SOPLE desaparecer y el resultado ser mostrado en unos segundos El alcoholimetro emitir una sefial ac stica una vez haya finalizado la prueba y la pantalla digital le mostrar durante un tiempo el resultado de la concentraci n de alcohol de la siguiente forma Si el resultado del test es inferior al nivel permitido s lo parpadeara el icono del coche Si el resultado del test es superior al nivel permitido la alarma ac stica sonar continuamente y al mismo tiempo el mensaje HI NIVEL ALTO y el icono No Driving parpedearan Este resultado se mantendr en la pantalla durante 10 segundos despu s el alcoholimetro se desconectara automaticamente emitiendo previamen
9. ies are too old Replace the batteries Failure in the circuit Contact technical service Wait for the warm up to conclude before carrying out the test The warm up process has not been completed It does not detect the presence of alcohol Failure in the circuit Contact technical service The screen shows FFF and it shuts down automatically Failure in the sensor Contact technical service The screen indicates that there is little batteryand it shuts down automatically Batteries are too old Replace the batteries Warning 1 The manufacturer distributor does not admit responsibility for the use of the device since this alcohol testing unit should never be used with the aim of carrying out tests validated by the authorities since these are not legally recognized The alcohol detector is an instrument of prevention and its results should only be considered a point of reference 2 Do not drive or operate machinery if you suspect or have reason to suspect your behavior could be affected by an alcohol intake even if the test indicates a level of alcohol below 0 25 Mg L in air 3 Ifyou drive or operate machinery after drinking alcohol you do so at your own risk There are no express or implicit guarantees in relation to the use of the device 4 Liability is only limited to the cost of the unit The warranty has a duration of 6 months from the unit s date of purchase with regard t
10. o any manufacturing defects If you require technical support warranty and operation questions please contact the CDP Customer Service Department at 34 902104060 or visit our website www cdpsa com where you will find further guidelines and instructions Other factors breath tobacco quality of the air etc may affect the measurement so please use these values as a reference only 11 Manual de instru es Zaphir CDP2000 Manual do utilizador Descri o do Produto O alcool metro Zaphir CDP2000 um aparelho de grande precis o para medir a concentra o de lcool na respira o humana Inclui um avan ado sensor NM Hot wire extremamente sens vel e fi vel Al m disso por ser um modelo de design moderno compacto e pequeno muito pr tico como alcool metro para utiliza o pessoal e profissional Quando a taxa de lcool ultrapassa o limite estabelecido o aparelho emite um aviso sonoro e uma mensagem de alerta no ecr Principais Caracter sticas Avan ado sensor de lcool NM Hot wire Tempo de resposta muito r pido Montagem atrav s de um sistema SMD que garante uma resposta est vel Modelo com Modo Inteligente Indicadores digitais certos no ecr Ecr digital com luz azul de fundo Design moderno e simples de utilizar Avisos ac sticos e digitais Sistema Auto check Fabricado com um sistema inteligente de poupan a de energia Especifica es t cnicas Tipo de sensor NM Hot wire
11. que uma taxa de lcool inferior a 0 25 mg L no ar Se conduzir ou manipular qualquer tipo de m quina ap s ter consumido lcool tem de assumir o risco que implica N o h garantias expressas ou impl citas relativamente utiliza o do aparelho A responsabilidade cinge se unicamente ao valor do aparelho A garantia de 6 meses a contar da data de compra para qualquer defeito de fabrico No caso de necessitar suporte t cnico por qualquer raz o garantia e consultas de funcionamento pode contactar com o departamento de Aten o ao Cliente da CDP ligando para o 902 10 40 60 ou atrav s da nossa Web www cdpsa es onde vai receber informa es certas para qualquer incid ncia Muitas outras causas h lito tabaco qualidade do ar etc podem interferir no teste Por isso os resultados obtidos devem ser tidos em considera o unicamente como refer ncia 17 CONSUMER DESIGN PRODUCTS ED Atenci n al Cliente 902 104060 Pol Ind P 29 28400 COLLADO VILLALBA Madrid WWW cdpsa es
12. ste resultado permanece no ecr durante 10 segundos e a seguir o aparelho vai desligarse automaticamente ap s um aviso sonoro de dois apitos Se quiser efectuar outro teste carregue novamente no bot o para ligar o alcool metro e repita o processo segundo as instru es acima referidas Importante Evite quedas e golpes Se o local onde vai efectuar o teste n o estiver bem arejado ou em ambientes pouco ventilados o aparelho pode n o funcionar correctamente 15 16 3 3 3 4 3 5 3 6 3 7 No caso de utilizar o alcoolimetro com as baterias muito gastadas os resultados poderiam ser err neos Use sempre pilhas alcalinas Para assegurar a fiabilidade do alcool metro mas comeu bebeu ou fumou espero pelo menos 15 minutos antes de efectuar o teste Por favor leia com aten o as instru es Se o alcool metro n o for utilizado durante um tempo prolongado quando quiser fazer um teste n o tenha em conta os resultados das duas primeiras an lises porque os resultados poderiam n o ser correctos Efectue sempre uma segunda an lise de valida o para confirmar o resultado Para uma boa manuten o do aparelho guarde sempre o seu alcool metro num lugar seco e bem ventilado no estojo de protec o fornecido juntamente com o produto Em condi es normais de utiliza o a vida til do sensor superior 2 anos 3 8 Se necess rio utilize um pano seco para limpar o aparelho NAO empregue gu
13. te dos se ales ac sticas Si quiere realizar un nuevo test presione el bot n de encendido y siga las mismas instrucciones Importante Evite ca das y golpes Si el lugar donde va a realizar su prueba no est bien ventilado el aparato podr a no funcionar correctamente 3 3 3 4 3 5 3 6 3 7 3 8 Si se usa el alcoholimetro con las baterias muy gastadas los resultados podrian ser err neos Instale siempre baterias alcalinas Para asegurar la fiabilidad en la medici n por favor abst ngase de beber comer o fumar al menos durante 15 minutos antes de realizar la prueba Por favor siga detenidamente las instrucciones Si el alcohol metro no se va a usar durante un largo per odo de tiempo cuando lo encienda nuevamente descarte los resultados de las dos primeras pruebas los resultados podrian ser err neos Realice siempre una segunda prueba de validaci n para confirmar el resultado Para una buena conservaci n guarde siempre su alcohol metro en un lugar seco y bien ventilado en la funda protectora suministrada con el producto En condiciones normales de uso la vida til del sensor es de m s de 2 afios Si fuera necesario use un trapo limpio para limpiarlo NO use agua ni disolventes o pulverizadores convencionales podr a da ar el aparato Soluciones para problemas comunes FALLO POSIBLE RAZ N SOLUCI N No se enciende la pantalla Bater as mal colocadas Inserte las ba
14. ter as correctamente siguiendo las indicaciones de polaridad Bater as muy gastadas Reemplace las bater as Fallo en el circuito Contacte con el serv tec No dectecta la presencia del alcohol No se ha completado el proceso de calentamiento Espere a que termine el proceso de pre calentamiento antes de realizar la prueba Fallo en el circuito Contacte con el serv tec La pantalla muestra FFF y se desconecta autom ticamente Fallo en el sensor Contacte con el serv tec La pantalla indica que queda poca bater a y se desconecta autom ticamente Bater as muy gastadas Reemplace las bater as Advertencias 1 El fabricante distribuidor no se responsabiliza de la utilizaci n de este aparato Este alcoholimetro nunca debe ser empleado con el prop sito de efectuar ensayos validados por las autoridades pues stos pueden no estar legalmente reconocidos El detector de alcohol es un instrumento de prevenci n y sus resultados deben ser considerados s lo como una medida de orientaci n 2 No conduzca u opere maquinar a si sospecha o tiene alguna raz n para sospechar que su comportamiento pueda estar afectado por el consumo de alcohol incluso si los test indican un grado de alcohol inferior a 0 25 mg L en aire 3 Si conduce u opera maquinar a despu s de haber consumido alcohol lo est haciendo asumiendo sus propios riesgos No existen garant as expresas o impl
15. udo num nico bot o Remova a tampa do compartimento das pilhas situado na parte de tr s do aparelho e coloque 3 pilhas do tipo AAA 1 5V prestando aten o ao alinhamento das baterias A seguir feche a tampa Carregue no bot o de alimenta o durante 1 segundo O alcool metro emite a seguir um aviso sonoro e no ecr aparece o s mbolo Wait AGUARDE A partir desse momento come a uma contagem decrescente de 20 0 e iniciado o processo de pr aquecimento Quando a mensagem Wait AGUARDE desaparecer vai ouvir um sinal sonoro e no ecr aparece o s mbolo Blow SOPRE Intermitentemente no ecr aparecem os s mbolos de um carro e ccc Nesse momento pode iniciar o teste Respire profundamente antes de fazer o teste e sopre directamente pela boquilha at ouvir um aviso sonoro O s mbolo intermitente 000 aparece no ecr durante 4 segundos a mensagem Blow SOPRE desaparece e o resultado da amostra aparece em poucos segundos Ir ouvir um aviso sonoro do resultado da amostra e no ecr aparece durante um tempo o resultado da an lise da concentra o de lcool da seguinte forma Se o resultado do teste for inferior ao n vel permitido s aparece O s mbolo do carro de forma intermitente Se o resultado do teste for superior ao n vel permitido o aviso sonoro ser continuado e no ecr aparecem intermitentemente os s mbolos HI N VEL ALTO e No Driving NAO CONDUZIR E
16. will remain on the screen during 10 seconds then the unit will automatically shutdown after emitting two sound signals If you want to carry out a new test press the on button and follow the same instructions Important Avoid hitting or dropping the unit If the place where you carry out the test is not well ventilated the device may not work correctly If the breath tester is used with old batteries the results could be erroneous Always install alkaline batteries To assure a reliable measurement please abstain from drinking eating or smoking at least during 15 minutes before carrying out the test 10 3 5 3 6 3 7 3 8 Please follow instructions carefully If the breath tester is not_used during a long period of time disregard the results of the first two tests the results could be erroneous Always carry out a second validation test to confirm the result For a proper maintenance always keep the device in a dry and well ventilated place in the protective case provided with the product Under normal conditions of use the useful life of the sensor exceeds 2 years If necessary use a clean cloth to clean it Don t use water solvent or conventional cleansers since these could damage the breath tester Troubleshooting common problems FAILURE POSSIBLE REASON SOLUTION Batteries Insert the batteries os not placed correctly correctly following the polarity indications does not turn on Batter

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書  G-6000. Controlador de Acceso Público  IBM 00NA261 hard disk drive  User Manual for Data Specialist Plus  ヒューマンエラー傾向自己診断手法の開発  Flexguard Catalogue click to - PTI Corp  Logic Code Combi ES Installation Guide  校正 / メンテナンス用溶液(日本語版)  

Copyright © All rights reserved.
Failed to retrieve file